2014 product catalogue
Transcription
2014 product catalogue
UPS.AC INVERTER.HYBRID INVERTER.SOLAR CHARGER CONTROLLER.AVR 2014 PRODUCT CATALOGUE WHY CENTRAION? Centralion Industrial Inc. (“Centralion”) was founded in 1979 and has become a leading developer of power quality solutions since 1989. With more than 30 years of experiences in the industry, Centralion’s power products have served all over the world as a key component in power systems which required uninterrupted power supply, and Centralion has won its reputation as a trustful and reliable partner for its customers. INDEX Online UPS INNOVA INNOVA+ INNOVA+ Z INNOVA COMBO INNOVA RT INNOVA HD JAGA ONL - 01 ONL - 05 ONL - 07 ONL- 09 Standby UPS AC Inverter APFC OFFICE MAX OFFICE Z MAX POWER DC UPS HYBRID INVEREX INVEREX S INVEREX Z INVEREX HD STB - 01 STB - 03 STB - 05 STB - 07 ONL - 11 ACI - 01 ACI - 03 ACI - 05 ACI - 07 ACI - 09 HOSTA VANDA IBERIS AVR - 01 AVR - 03 AVR - 05 Accessory ONL - 15 NMC CARD ACC - 01 ONL - 17 AS400 CARD ACC - 01 Modular UPS Line-interactive UPS SPRING MT SPRING MTZ SPRING RT AURORA AURORA VISTA UNI UNI Z BLAZER VISTA AVR GRIPOWER PRO Solar Charger Controller MDL - 01 SOLAR MATE SCC - 01 LIN - 01 LIN - 03 LIN - 05 LIN - 09 LIN - 11 3-Phase UPS APUS APUS Z Solar Inverter 3PH - 01 3PH - 03 LIN - 13 LIN - 15 LIN - 17 GRID-TIED SINGLE-PHASE SUNVILLE SLI - 01 GRID-TIED THREE-PHASE SUNVILLE SLI - 03 CMC CARD ACC - 01 MINI NMC CARD ACC - 02 MINI AS400 CARD ACC - 02 MINI CMC CARD ACC - 02 RELAY CARD ACC - 03 USB/RS232CARD ACC - 03 Environmental Monitoring Probe (EMP) ACC - 03 EXTERNAL CHARGER ACC - 04 Automatic Transfer Switch (ATS) ACC - 04 COMPATIBILITY MATRIX ACC - 05 Product series marked with “Z” are designed for 100-120V system. Product specification and outlook are subject to change without prior notice. Online UPS INNOVA series KEY FEATURES • True double-conversion design with high adaptability to harsh mains conditions • DSP design enables precise and reliable control • High efficiency results in energy saving 2K / 3K • Automatic boost/buck voltage regulation (± 2%) • Supports energy-saving ECO mode • Intelligent communication slot enables remote monitoring • LCD display shows easy-to-understand operational status 1K TYPICAL APPLICATION ONL - 01 Online UPS SPECIFICATION MODEL INNOVA TOWER 1K CAPACITY INPUT OUTPUT EFFICIENCY BATTERY TRANSFER TIME DISPLAY AUDIBLE ALARM DIMENSION NET WEIGHT ENVIRONMENT INTERFACE Input Voltage Range Frequency Range Input Wiring Current Distortion (THDi) Output Power Factor Nominal Output Voltage Voltage Regulation Frequency Range ( Battery Mode ) Current Crest Ratio Voltage Distortion (THDv) Output Waveform Parallel Operation Inverter Mode Battery Mode ECO Mode Battery Type Number of Internal Battery Rated Battery Voltage Backup Time (@ Full Load) Recharge Time (to 90%) Charging Current Battery Mode ↔ Inverter Mode Inverter Mode ↔ Bypass Mode ECO Mode ↔ Battery Mode WxHxD Operating Temperature Noise Level RS232/USB External Slot Emergency Power Off INNOVA TOWER 1KS INNOVA TOWER 2K 1000VA/800W 2000VA/1600W 110 ~ 300 VAC 45 Hz– 55 Hz/54 Hz – 66 Hz Single Phase with Ground <5% @ full load 0.8 2001/2082/220/230/240VAC ±2 % 50 / 60 ± 0.2Hz 3:1 < 3% @ linear load, < 5%@ non-linear load Pure Sine Wave N/A 88% 85% 93% 94% 12V / 7Ah N/A 12V / 7Ah 3 N/A 8 36V 96V > 5min N/A > 9min 5 hour N/A 5 hour 1A 8A 1A 0ms 4ms <10ms LCD Yes 145 X 220 X 400 mm 192 X 347 X 460 mm 13 kg 7 kg 31 kg 13 kg 0~45 °C 50dB @1 meter Yes Yes Yes Note: 1. 200VAC will be subject to 80% output derating 2. 208VAC will be subject to 90% output derating ONL - 02 INNOVA TOWER 2KS INNOVA TOWER 3K INNOVA TOWER 3KS 3000VA/2400W N/A N/A N/A N/A 8A or 12A (optional) 31 kg 12V / 7Ah 8 96V > 5min 5 hour 1A N/A N/A N/A N/A 8A or 12A (optional) 13 kg Online UPS INNOVA series KEY FEATURES • True double-conversion design with high adaptability to harsh mains conditions • DSP design enables precise and reliable control • High output power factor (0.9) • High efficiency results in energy saving • Automatic boost/buck voltage regulation (±1%) • Supports energy-saving ECO mode • Intelligent communication slot enables remote monitoring 6K / 10K • LCD display shows easy-to-understand operational status • Supports up to 4-unit parallel operation TYPICAL APPLICATION ONL - 03 Online UPS SPECIFICATION MODEL CAPACITY INPUT OUTPUT EFFICIENCY BATTERY TRANSFER TIME DISPLAY AUDIBLE ALARM DIMENSION NET WEIGHT ENVIRONMENT INTERFACE Input Voltage Range Frequency Range Input Wiring Current Distortion (THDi) Output Power Factor Nominal Output Voltage Voltage Regulation Frequency Range ( Battery Mode ) Current Crest Ratio Voltage Distortion (THDv) Output Waveform Parallel Operation Inverter Mode Battery Mode ECO Mode Battery Type Number of Internal Battery Rated Battery Voltage Backup Time (@ full load) Recharge Time (to 90%) Charging Current Battery Mode ↔ Inverter Mode Inverter Mode ↔ Bypass Mode ECO Mode ↔ Battery Mode WxHxD Operating Temperature Noise Level RS232/USB External Slot Emergency Power Off INNOVA 6K INNOVA 6KS 6000VA/5400W 110~276VAC 45-55Hz / 54-66Hz Single phase with ground <5% @ full R load 0.9 2081/220/230/240VAC ±1% 50/60 ± 0.05 Hz 3:1 <2% @ Linear Load, <5% @ Non-Linear Load Pure Sine Wave Up to 4 units >92% >92% >96% 12V/7Ah N/A 20 N/A 240VDC > 5min N/A 5 hour N/A 1.4A 4A 0ms 0ms 10ms LCD Yes 260 x 708 x 550 mm 88 kg 25.5 kg 0-45° C ≤50dB @ 1 Meter RS23: optional, USB: standard Yes Yes Note: 1. 208VAC will be subject to 90% output derating ONL - 04 INNOVA 10K 10000VA/9000W INNOVA 10KS 12V/9Ah 20 N/A N/A > 4 min 5 hour 1.4A N/A N/A 4A 84 kg 29.5 kg Online UPS INNOVA+ KEY FEATURES series • True double-conversion design with high adaptability to harsh mains conditions • DSP design enables precise and reliable control • High efficiency results in energy saving 2K / 3K • Output power factor (0.9) • Automatic boost/buck voltage regulation (± 2%) • Supports energy-saving ECO mode • Intelligent communication slot enables remote monitoring 1K TYPICAL APPLICATION ONL - 05 Online UPS SPECIFICATION MODEL CAPACITY INPUT OUTPUT EFFICIENCY BATTERY TRANSFER TIME DISPLAY AUDIBLE ALARM DIMENSION NET WEIGHT ENVIRONMENT INTERFACE Input Voltage Range Frequency Range Input Wiring Current Distortion (THDi) Output Power Factor Nominal Output Voltage Voltage Regulation Frequency Range ( Battery Mode ) Current Crest Ratio Voltage Distortion (THDv) Output Waveform Parallel Operation Inverter Mode Battery Mode ECO Mode Battery Type Number of Internal Battery Rated Battery Voltage Backup Time (PF0.8 , full load) Recharge Time (to 90%) Charging Current Battery Mode ↔ Inverter Mode Inverter Mode ↔ Bypass Mode ECO Mode ↔ Battery Mode WxHxD Operating Temperature Noise Level USB External Slot Emergency Power Off INNOVA+ 1K INNOVA+ 1KS 1000VA/900W 110 ~ 300 Vac 45~55 Hz/54~66 Hz Single Phase with Ground <5% with full load 0.9 2001/2082/220/230/240VAC ±2 % 50/60Hz ±0.2 Hz 3:1 <3% @ linear load, <5% @non-linear load Pure Sine Wave N/A 87% 85% 93% 12V / 7Ah N/A 3 N/A 36V 36V 5 min N/A 5 hours N/A 1A 8A 0ms <4ms <10ms LCD Yes 145 X 220 X 400 mm 13 kg 7 kg 0~45 °C <50dB @1 meter Yes Yes Yes Note: 1. 200VAC will be subject to 80% output derating 2. 208VAC will be subject to 90% output derating LIN - 06 INNOVA+ 2K 2000VA/1800W INNOVA+ 2KS INNOVA+ 3K 3000VA/2700W INNOVA+ 3KS N/A N/A 96V N/A N/A 8A or 12A(optional) 12V / 7Ah 8 96V 5 min 5 hours 1A N/A N/A 96V N/A N/A 8A or 12A(optional) 31 kg 13 kg 88% 94% 12V / 7Ah 8 96V 9 min 5 hours 1A 192 X 347 X 460 mm 31 kg 13 kg Online UPS INNOVA+ Z series KEY FEATURES • High-frequency design and full-digital DSP control provide optimal performance • High output power factor (0.9) 2K / 3K • Wide input voltage range (55~150Vac) • Precise output voltage regulation ( 1%) • Graphic LCD display • Intelligent communication slot enables remote monitoring • Supports ECO mode and power segments • cTÜ Vus certified 1K TYPICAL APPLICATION ONL - 07 Online UPS SPECIFICATION MODEL CAPACITY INPUT OUTPUT EFFICIENCY BATTERY TRANSFER TIME DISPLAY AUDIBLE ALARM DIMENSION NET WEIGHT ENVIRONMENT INTERFACE Input Voltage Range Frequency Range Input Wiring Current Distortion (THDi) Output Power Factor Nominal Output Voltage Voltage Regulation Frequency Range ( Battery Mode ) Current Crest Ratio Voltage Distortion (THDv) Output Waveform Parallel Operation Inverter Mode Battery Mode ECO Mode Battery Type Number of Internal Battery Rated Battery Voltage Backup Time (@ Full Load) Recharge Time (to 90%) Charging Current Battery Mode ↔ Inverter Mode Inverter Mode ↔ Bypass Mode ECO Mode ↔ Battery Mode WxHxD Operating Temperature Noise Level RS232/USB External Slot Emergency Power Off INNOVA+ Z 1K INNOVA+ Z 2K 1000VA/900W 2000VA/1800W 55~150VAC 46-54Hz / 56-64Hz Single Phase with Ground <15% with full R load <10% with full R load 0.9 1001/1102/115/120VAC/127VAC ±1% 50/60Hz ±0.1 Hz 3:1 <4% @ linear load ; <8% @ non-linear load Pure Sine Wave N/A 89.0 % 90.0% 86.0% 85.9% 96.0% 96.0% 12V/7.2Ah 12V/7.2Ah 3 6 36V 96V >5 min >5 min 5 hours 1A 0ms <4ms <10ms LCD Yes 145 X 220 X 345 mm 190 X 318 X 383 mm 12.5 kg 25 kg 0~40 °C <45dB @ 1 meter Yes Yes Yes Note: 1. 100VAC will be subject to 90% output derating for 1K and 3K models, and 80% output derating for 2K model 2. 110VAC will be subject to 90% output derating for 2K model ONL - 08 INNOVA+ Z 3K 3000VA/2700W <15% with full R load 88.9% 84.8% 96.0% 12V/9Ah 6 96V >4 min 27.1 kg Online UPS INNOVA COMBO series KEY FEATURES • True double-conversion design to deal with harsh mains conditions • High output power factor (0.9) • Precise output voltage regulation ( 1%) • Wide AC input voltage range (110-276VAC) • LCD display shows easy-to-understand operational status • Supports energy-saving ECO mode • Two Intelligent communication slots and one RS232 port enable up to 3 channels remote monitoring 10K / 20K • Supports parallel connection for up to 4 units TYPICAL APPLICATION ONL - 09 Online UPS SPECIFICATION MODEL CAPACITY Input Voltage Range INPUT OUTPUT EFFICIENCY BATTERY TRANSFER TIME DISPLAY AUDIBLE ALARM DIMENSION NET WEIGHT ENVIRONMENT INTERFACE Frequency Range Input Wiring Current Distortion (THDi) Output Power Factor Nominal Output Voltage Voltage Regulation Frequency Range ( Battery Mode ) Current Crest Ratio Voltage Distortion (THDv) Output Waveform Parallel Operation Inverter Mode Battery Mode ECO Mode Battery Type Number of Internal Battery Rated Battery Voltage Backup Time (@ Full Load) Recharge Time (to 90%) Charging Current Battery Mode ↔ Inverter Mode Inverter Mode ↔ Bypass Mode ECO Mode ↔ Battery Mode WxHxD Operating Temperature Noise Level RS232/USB External Slot Emergency Power Off INNOVA COMBO 10K INNOVA COMBO 20K 10000 VA/ 9000W 20000VA/18000W 110VAC-276VAC (Single Phase Input) 190VAC-478VAC (Three Phase Input) 45Hz ~ 55Hz / 54Hz ~ 66Hz Single Phase with Ground (L-N-G) /Three Phase with Ground (R-S-T-N-G) < 5% @ full R load 0.9 2001/208/220/230/240VAC ±1% 50/60 ± 0.05 Hz 3:1 <2% @ Linear Load, <5% @ Non-Linear Load Pure Sine Wave Up to 4 units >93% >93% >97% 12V/9Ah 24x1 24x2 288VDC 288 VDC >5 minutes 3 hours 5 hours 2A 4A 0ms 0ms <10ms LCD Yes 350 x 890 x 650 115 kg 183 kg 0-45° C <55dB @ 1 Meter Yes Yes Yes Note: 1. 200VAC will be subject to 90% output derating ONL - 10 Online UPS INNOVA RT series KEY FEATURES • True double-conversion design with high adaptability to harsh mains conditions • Ideal to for high-end equipment which are sensitive to power quality • Supports energy-saving ECO mode • Wide input range (120-176VAC) 1K / 1.5K / 2K / 3K • Intelligent communication slot enables remote monitoring • Precise output voltage regulation (1%) • Rack/tower dual set-up with rotatable LCD panel TYPICAL APPLICATION ONL - 11 Online UPS SPECIFICATION MODEL INNOVA RT 1K CAPACITY 1000VA/900W 1500VA/1350W 120~176VAC 45~55Hz/54~66Hz Single Phase with ground <5% @ full load 0.9 208/220/230/240VAC ± 1% 50/60 ± 0.2 Hz 3:1 <2% @ Linear Load, <5% @ Non-Linear Load Pure Sine Wave N/A 88% 89% 83% 84% 95% 12V/7Ah N/A 12V/7Ah N/A 3 N/A 4 N/A 36VDC 48VDC > 5min N/A > 5min N/A 3 hour N/A 3 hour N/A 1.5A 6A 1.5A 6A 0 ms 4 ms <10 ms LCD Yes 438 x 86.5 x 435 mm 16.2 kg 8.4 kg 19.7 kg 9.3 kg 0-40° C <45dB @ 1 Meter <50dB @ 1 Meter Yes Yes Yes Input Voltage Range Frequency Range INPUT Input Wiring Current Distortion (THDi) Output Power Factor Nominal Output Voltage Voltage Regulation Frequency Range ( Battery Mode ) OUTPUT Current Crest Ratio Voltage Distortion (THDv) Output Waveform Parallel Operation Inverter Mode EFFICIENCY Battery Mode ECO Mode Battery Type Number of Internal Battery Rated Battery Voltage BATTERY Backup Time (@ Full Load) Recharge Time (to 90%) Charging Current (max) Battery Mode ↔ Inverter Mode TRANSFER TIME Inverter Mode ↔ Bypass Mode ECO Mode ↔ Battery Mode DISPLAY AUDIBLE ALARM DIMENSION WxHxD NET WEIGHT Operating Temperature ENVIRONMENT Noise Level RS232/USB INTERFACE External Slot Emergency Power Off INNOVA RT 1KS INNOVA RT 1.5K INNOVA RT 1.5KS ONL - 12 INNOVA RT 2K INNOVA RT 2KS INNOVA RT 3K 2000VA/1800W 3000VA/2700W INNOVA RT 3KS 92% 88% 12V/9Ah 4 48VDC > 5min 3 hour 1.5A N/A N/A 19.7 kg 9.3kg N/A N/A 6A 12V/9Ah 6 72VDC > 5min 3 hour 1.5A N/A N/A N/A N/A 6A 438 X 86.5X 604 mm 27.8 kg 13 kg Online UPS INNOVA RT series KEY FEATURES • True double-conversion design with high adaptability to harsh mains conditions • Ideal to for high-end equipment which are sensitive to power quality • Supports energy-saving ECO mode • Wide input range (120-276VAC) 6K • Intelligent communication slot enables remote monitoring • Precise output voltage regulation (1%) • Independent input for bypass operation 10K TYPICAL APPLICATION ONL - 13 Online UPS SPECIFICATION MODEL CAPACITY INPUT OUTPUT EFFICIENCY BATTERY TRANSFER TIME DISPLAY AUDIBLE ALARM DIMENSION NET WEIGHT ENVIRONMENT INTERFACE Input Voltage Range Frequency Range Input Wiring Current Distortion (THDi) Output Power Factor Nominal Output Voltage Voltage Regulation Frequency Range ( Battery Mode ) Current Crest Ratio Voltage Distortion (THDv) Output Waveform Parallel Operation Inverter Mode Battery Mode ECO Mode Battery Type Number of Internal Battery Rated Battery Voltage Backup Time (@ Full Load) Recharge Time (to 90%) Charging Current Battery Mode ↔ Inverter Mode Inverter Mode ↔ Bypass Mode ECO Mode ↔ Battery Mode WxHxD Operating Temperature Noise Level RS232/USB External Slot Emergency Power Off INNOVA RT 6K INNOVA RT 6KS 6000VA/5400W 120~276VAC 45-55Hz / 54-66Hz Single phase with ground <5% @ full load 0.9 208/220/230/240VAC ± 1% 50/60 ± 0.1 Hz 3:1 <2% @ Linear Load, <5% @Non-Linear Load Pure Sine Wave N/A 92% 89% 96% 12V/5Ah N/A 15 N/A 180VDC >2.5mins N/A 3 hours N/A 1A 8A 0 ms 0 ms <10 ms LCD Yes 438 x 129x 698 mm 438 x 129x 640 mm 46kg 19 kg 0-40° C <55dB @ 1 Meter Yes Yes Yes ONL - 14 INNOVA RT 10K 10000VA/9000W INNOVA RT 10KS 93% 90% 97% 12V/9Ah 20 240VDC > 3.5mins 3 hours 1.7A N/A N/A 8A 438 x 215.5x 704 mm 82.5kg 438 x 215.5x 640 mm 26kg N/A N/A Online UPS INNOVA HD series KEY FEATURES • True double-conversion design with high adaptability to harsh mains conditions • DSP design enables precise and reliable control • High efficiency results in energy saving • Output power factor 0.9 1K / 2K / 3K • Precise voltage regulation (± 2 %) • Intelligent communication slot enables remote monitoring • Standard rack design for installation in cabinet TYPICAL APPLICATION ONL - 15 Online UPS SPECIFICATION MODEL CAPACITY Input Voltage Range Frequency Range INPUT Input Wiring Current Distortion (THDi) Output Power Factor Nominal Output Voltage Voltage Regulation Frequency Range ( Battery Mode ) OUTPUT Current Crest Ratio Voltage Distortion (THDv) Output Waveform Parallel Operation Inverter Mode EFFICIENCY Battery Mode ECO Mode Battery Type Number of Internal Battery BATTERY Rated Battery Voltage Backup Time (@ full load) Recharge Time (to 90%) Battery Mode ↔ Inverter Mode TRANSFER TIME Inverter Mode ↔ Bypass Mode ECO Mode ↔ Inverter Mode DISPLAY AUDIBLE ALARM DIMENSION WxHxD NET WEIGHT Operating Temperature ENVIRONMENT Noise Level RS232/USB INTERFACE External Slot Emergency Power Off Note: 1. 100VAC will be subject to 80% output derating 2. 110VAC will be subject to 90% output derating INNOVA HD 1K INNOVA HD 2K 1000VA/900W 2000VA/1600W 80~144VAC 90~138VAC 50/60Hz Single phase with ground <8% 0.9 1001/1102/120/127VAC 2% 50/60Hz 0.1 Hz 3:1 < 3 % @ linear load, < 5 % @ non-linear load Pure sine wave N/A 87% 88% 82% 84% 93% 12V/9Ah 3 6 36V 72V 6 min 6 min 3 hours 0 ms 4 ms 10 ms LCD Yes 438 x 86.5 x 445 mm 438 x 86.5 x 610 mm 16 kg 29 kg 0 ~ 40 °C <50 dBA Yes Yes Yes ONL - 16 INNOVA HD 3K 3000VA/2700W 90% 3 min 29 kg Online UPS JAGA series KEY FEATURES 2K / 3K • True double-conversion design with high adaptability to harsh mains conditions • DSP design enables precise and reliable control • High efficiency results in energy saving • Output power factor 0.8 (up to 0.9 under 30℃) • Wide AC input range (110-300VAC) • Automatic switching between 50/60Hz system • Precise voltage regulation (± 1 %) • Supports AC generator • Supports DC start-up and auto restart • Intelligent communication slot enables remote monitoring 1K TYPICAL APPLICATION ONL - 17 Online UPS SPECIFICATION MODEL CAPACITY Input Voltage Range Frequency Range INPUT Input Wiring Current Distortion (THDi) Output Power Factor Nominal Output Voltage Voltage Regulation Frequency Range ( Battery Mode ) OUTPUT Current Crest Ratio Voltage Distortion (THDv) Output Waveform Parallel Operation Inverter Mode EFFICIENCY Battery Mode ECO Mode Battery Type Number of Internal Battery Rated Battery Voltage BATTERY Backup Time (@ Full Load) Recharge Time (to 90%) Charging Current (max) Battery Mode ↔ Inverter Mode TRANSFER TIME Inverter Mode ↔ Bypass Mode DISPLAY AUDIBLE ALARM DIMENSION WxHxD NET WEIGHT Operating Temperature ENVIRONMENT Noise Level RS232 INTERFACE External Slot Emergency Power Off Note: 1. 200VAC will be subject to 80% output derating 2. 208VAC will be subject to 80% output derating JAGA 1K JAGA 2K 1000VA/800W 2000VA/1600W 110~300VAC 40-70Hz Single phase with ground <10% 0.8 2001/2082/220/230/240VAC ±2% 50/60 ± 0.05 Hz 2.95:1 < 4% @ linear load, < 7% @ non-linear load Pure sine wave N/A >89% >90% >83% >83% N/A 12V/45W 2 4 24VDC 48VDC 4.5 min 4.5 min 7 hours 7 hours 1A 1A 0ms 4ms LCD Yes 144 x 229 x 345 mm 190 x 328 x 393 mm 9.2 kg 17.2 kg 0 ~ 40 °C <45dB <50dB Yes Yes No ONL - 18 JAGA 3K 3000VA/2400W >83% 6 72VDC 4.5 min 7 hours 1A 22.6 kg Line-interactive UPS SPRING MT series KEY FEATURES 1000 / 1500 • High performance supported by sinewave output and built-in voltage regulator • Compact foot print fits easily into small spaces such as kiosks, cash machines and ticket machines • HID Power Device-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS and Linux • High conversion efficiency (>95%) results in energy saving • LCD graphic display gives comprehensive information at a glance • Easy battery replacement TYPICAL APPLICATION 500 / 750 LIN - 01 Line-interactive UPS SPECIFICATION MODEL CAPACITY INPUT OUTPUT EFFICIENCY BATTERY SPRING MT 750 750VA/450W SPRING MT 1000 1000VA/700W SPRING MT 1500 1500VA/900W Input Voltage Range Frequency Range Input Wiring Output Power Factor Nominal Output Voltage Voltage Regulation (Line Mode) Voltage Regulation (Battery Mode) Frequency Range ( Battery Mode ) Output Waveform Parallel Operation Line Mode AVR Mode Battery Mode Battery Type Number of Internal Battery Rated Battery Voltage SPRING MT 500 500VA/350W 176-288VAC 45-55 Hz / 55-65 Hz Single phase with ground 0.7 220/230/240VAC -10% ~ +6% -10% ~ +6% 50/60 Hz ±0.1 Hz Pure sine wave N/A > 94% > 90% > 70% 12V/7Ah 1 12VDC 0.6 0.7 0.6 12V/9Ah 1 12V/7Ah 2 24VDC 12V/9Ah 2 Backup Time (@ Typical PC load) 17 min 20 min 35 min 40 min 6.8 kg 150x209x340 mm 10.8 kg 11.5 kg Recharge Time (to 90%) TRANSFER TIME Battery Mode ↔ Line Mode DISPLAY 3 hours <10ms LCD AUDIBLE ALARM Yes DIMENSION NET WEIGHT WxHxD Operating Temperature ENVIRONMENT Noise Level INTERFACE USB 150x209X240 mm 6.4 kg 0~40° C <40dBA @ 1 meter Yes <45 dBA@1 meter LIN - 02 Line-interactive UPS SPRING MTZ series KEY FEATURES 1000 / 1500 • Designed for 110/120VAC AC grid system • High performance supported by sinewave output and built-in voltage regulator • Compact foot print fits easily into small spaces such as kiosks, cash machines and ticket machines • HID Power Device-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS and Linux • High conversion efficiency (>95%) results in energy saving • LCD graphic display gives comprehensive information at a glance • Easy battery replacement TYPICAL APPLICATION 500 / 750 LIN - 03 Line-interactive UPS SPECIFICATION MODEL CAPACITY INPUT OUTPUT EFFICIENCY BATTERY SPRING MTZ 750 750VA/450W SPRING MTZ 1000 1000VA/700W SPRING MTZ 1500 1440VA/900W Input Voltage Range Frequency Range Input Wiring Output Power Factor Nominal Output Voltage Voltage Regulation (Line Mode) Voltage Regulation (Battery Mode) Frequency Range ( Battery Mode ) Output Waveform Parallel Operation Line Mode AVR Mode Battery Mode Battery Type Number of Internal Battery Rated Battery Voltage SPRING MTZ 500 500VA/350W 88-144VAC 45-55 Hz / 55-65 Hz Single phase with ground 0.7 100/110/120VAC -10% ~ +6% -10% ~ +6% 50/60 Hz ±0.1 Hz Pure sine wave N/A > 94% > 90% > 70% 12V/7Ah 1 12VDC 0.6 0.7 0.625 12V/9Ah 1 12V/7Ah 2 24VDC 12V/9Ah 2 Backup Time (@ Typical PC load) 17 min 20 min 35 min 40 min 6.8 kg 150x209x340 mm 10.8 kg 11.5 kg Recharge Time (to 90%) TRANSFER TIME Battery Mode ↔ Line Mode DISPLAY 3 hours <10ms LCD AUDIBLE ALARM Yes DIMENSION NET WEIGHT WxHxD Operating Temperature ENVIRONMENT Noise Level INTERFACE USB 150x209X240 mm 6.4 kg 0~40° C <40dBA @ 1 meter Yes <45 dBA@1 meter LIN - 04 Line-interactive UPS SPRING RT series KEY FEATURES • High output power factor (0.9) • Built-in voltage regulator stables unstable AC input power • Intelligent communication slot enables remote monitoring • HID Power Device-compliant USB interface enables integration with builtin power management and auto shutdown features of Windows and Mac OS and Linux 1K / 1.5K • Rack/tower dual set-up with rotatable LCD panel • Optional EBM (Extended Battery Module) available for battery expansion TYPICAL APPLICATION LIN - 05 Line-interactive UPS SPECIFICATION MODEL CAPACITY INPUT OUTPUT EFFICIENCY BATTERY Input Voltage Range Frequency Range Input Wiring Current Distortion (THDi) Output Power Factor Nominal Output Voltage Voltage Regulation (Line Mode) Voltage Regulation (Battery Mode) Frequency Range ( Battery Mode ) Voltage Distortion (THDv) Output Waveform Parallel Operation Line Mode AVR Mode Battery Mode Battery Type Number of Internal Battery Rated Battery Voltage Backup Time (@ full load) Recharge Time (to 90%) Charging Current Battery Mode ↔ Line Mode TRANSFER TIME DISPLAY AUDIBLE ALARM DIMENSION WxHxD NET WEIGHT Operating Temperature ENVIRONMENT Noise Level RS232/USB INTERFACE External Slot Dry Contact SPRING RT 1K SPRING RT 1KS 1000VA/900W 154~288VAC 45-55Hz / 55-65 Hz Single phase with ground 10% 0.9 220/230/240VAC -10% ~ +6% ±5% 50/60 Hz ± 0.1 Hz < 3% @ linear load, < 6% @ non-linear load Pure sine wave N/A 97% Boost mode: 92%, Buck mode: 95% >82% 12V/7Ah N/A 3 N/A 36VDC 4.5 min N/A 3 hours N/A 1.5A 7A 2-6 ms LCD Yes 438 X 86.5 x 435 mm 16kg 10kg 0~40°C <45dB Yes Yes Yes LIN - 06 SPRING RT 1KE SPRING RT 1.5K 1500VA/1350W SPRING RT 1.5KS < 10% @ linear load < 3% @ linear load, < 6% @ non-linear load >80% 12V/9Ah 2 24VDC 3min 8 hours 1.1A >82% 12V/9Ah 3 36VDC 3 min 4 hours 1.5A 13kg 17.9kg N/A N/A Yes Yes N/A N/A N/A N/A 7A 10kg Line-interactive UPS SPRING RT series KEY FEATURES • High output power factor (0.9) • Built-in voltage regulator stables unstable AC input power • Intelligent communication slot enables remote monitoring • HID Power Device-compliant USB interface enables integration with builtin power management and auto shutdown features of Windows and Mac OS and Linux 2K / 3K • Rack/tower dual set-up with rotatable LCD panel • Optional EBM (Extended Battery Module) available for battery expansion TYPICAL APPLICATION LIN - 07 Line-interactive UPS SPECIFICATION MODEL CAPACITY INPUT OUTPUT EFFICIENCY BATTERY TRANSFER TIME DISPLAY AUDIBLE ALARM DIMENSION NET WEIGHT ENVIRONMENT INTERFACE Input Voltage Range Frequency Range Input Wiring Current Distortion (THDi) Output Power Factor Nominal Output Voltage Voltage Regulation (Line Mode) Voltage Regulation (Battery Mode) Frequency Range ( Battery Mode ) Voltage Distortion (THDv) Output Waveform Parallel Operation Line Mode AVR Mode Battery Mode Battery Type Number of Internal Battery Rated Battery Voltage Backup Time (@ full load) Recharge Time (to 90%) Charging Current Battery Mode ↔ Line Mode WxHxD Operating Temperature Noise Level RS232/USB External Slot Dry Contact SPRING RT 2K SPRING RT 2KS 2000VA/1800W 154~288 VAC 45-55Hz / 55-65 Hz Single phase with ground 10% 0.9 220/230/240VAC -10% ~ +6% ±5% 50/60 Hz ± 0.1 Hz < 3% @ linear load, < 6% @ non-linear load Pure sine wave N/A 97% Boost mode: 92%, Buck mode: 95% 80% 12V/7Ah N/A 6 N/A 72VDC 4.5 min N/A 3 hours N/A 1.5A 7A 2-6 ms LCD Yes 438 X 86.5 x 604 mm 28kg 16kg 0~40°C <45dB Yes Yes Yes LIN - 08 SPRING RT 2KE SPRING RT 3K 3000VA/2700W SPRING RT 3KS 12V/9Ah 4 48VDC 3 min 4 hours 1.5A 12V/9Ah 6 72VDC 3 min 4 hours 1.5A N/A N/A 438 X 86.5 x 436 mm 21kg 438 X 86.5 x 604 mm 31kg N/A N/A 7A 16kg Line-interactive UPS AURORA series KEY FEATURES • Entry-level backup solution with excellent performance • Build-in voltage regulator for reliable power quality • DC start function enables UPS to be started up without AC power • Green Power Function for energy saving 1200 / 2200 • Auto restart while AC recovery • AC Overloading protection • Surge protection for phone / modem line • CE compliant 450 / 650 / 850 TYPICAL APPLICATION LIN - 09 Line-interactive UPS SPECIFICATION MODEL CAPACITY INPUT OUTPUT EFFICIENCY BATTERY TRANSFER TIME DISPLAY AUDIBLE ALARM DIMENSION NET WEIGHT ENVIRONMENT ARURORA 450 AURORA 650 450VA/240W 650VA/360W Input Voltage Range 162-290VAC Frequency Range 45~55Hz/55~65Hz Input Wiring Single phase with ground Output Power Factor 0.55 Nominal Output Voltage 110/120/220/230/240 Vac ±15% Voltage Regulation (Line Mode) Voltage Regulation (Battery Mode) ±10% Frequency Range ( Battery Mode ) 50/60Hz 1Hz Output Waveform Modified sine wave Parallel Operation N/A Line Mode 95% AVR Mode 88% Battery Mode 60% Battery Type 12V/4.5Ah 12V/7Ah Number of Internal Battery 1 1 Rated Battery Voltage 12VDC 12VDC Backup Time (@ Typical PC load) 8 min 16 min Recharge Time (to 90%) 6 hours Charging Current 1A Battery Mode ↔ Line Mode 2-6 ms LED YES WxHxD 100 x 143 x 300 3.5kg 4.5kg Operating Temperature 0~40°C Noise Level <40dB LIN - 10 AURORA 850 850VA/480W AURORA 1200 1200VA/600W AURORA 2200 2200VA/1100W 0.5 12V/9Ah 1 12VDC 20 min 12V/7Ah 2 24VDC 40 min 12V/9Ah 2 24VDC 50 min 4-8 ms 5.0kg 139 X 195 x 364 8.8kg 10.3kg <45dB Line-interactive UPS AURORA VISTA series KEY FEATURES • Entry-level backup solution with excellent performance • Build-in voltage regulator for reliable power quality • DC cold start function 1200 / 2200 • Auto restart while AC recovery • Front panel USB interface for easy installation(650/850) • Easy-to-understand graphic LCD display • AC Overloading protection • Surge protection for phone / modem line • CE compliant 650 / 850 TYPICAL APPLICATION LIN - 11 Line-interactive UPS SPECIFICATION MODEL CAPACITY INPUT OUTPUT Input Voltage Range Frequency Range Input Wiring Output Power Factor Nominal Output Voltage Voltage Regulation (Line Mode) AURORA VISTA 650 650VA/360W 162~290VAC 45~55/55~65 Hz Single phase with ground 0.55 220/230/240 VAC ±15% Voltage Regulation (Battery Mode) ±10% Frequency Range ( Battery Mode ) Output Waveform Parallel Operation Line Mode EFFICIENCY AVR Mode Battery Mode Battery Type Number of Internal Battery Rated Battery Voltage BATTERY Backup Time (@ Typical PC load) Recharge Time (to 90%) Charging Current TRANSFER TIME Battery Mode ↔ Line Mode DISPLAY AUDIBLE ALARM DIMENSION WxHxD NET WEIGHT Operating Temperature ENVIRONMENT Noise Level USB INTERFACE External Slot TVSS protection 50/60Hz 1 Hz Modified sine wave N/A 95% 88% 60% 12V/7Ah 1 12VDC 16 min 6 hours 1A 2-6 ms LCD Yes 100 x 143x 290 2.36 kg 0~40°C <40dB Yes No RJ11 Jack AURORA VISTA 850 850VA/480W AURORA VISTA 1200 1200VA/600W AURORA VISTA 2200 2200VA/1200W 0.56 0.5 0.55 12V/9Ah 1 12VDC 20 min 12V/ 7Ah 2 24VDC 30 min 12V/9Ah 2 24VDC 50 min 4-8 ms 2.7 kg 139 x 195 x 364 5.3 kg 5.93kg <45dB RJ45 Jack LIN - 12 Line-interactive UPS UNI KEY FEATURES series • Ideal backup power solution for home and office • Optimized design leads to cost-saving and space-saving • Boost and buck circuit to deal with challenging power conditions • Compact size which can be easily fit with PC-related equipment • Top access of outlet makes power core connection easier 600 TYPICAL APPLICATION LIN - 13 Line-interactive UPS SPECIFICATION MODEL CAPACITY INPUT OUTPUT EFFICIENCY BATTERY TRANSFER TIME DISPLAY AUDIBLE ALARM DIMENSION NET WEIGHT ENVIRONMENT INTERFACE Input Voltage Range Frequency Range Input Wiring Output Power Factor Nominal Output Voltage Voltage Regulation (Line Mode) UNI 600 600VA/360W 150~290VAC 47~53/57~63 Hz Single phase with ground 0.6 230VAC N/A Voltage Regulation (Battery Mode) ±10% Frequency Range ( Battery Mode ) Output Waveform Parallel Operation Line Mode AVR Mode Battery Mode Battery Type Number of Internal Battery Rated Battery Voltage Backup Time (@ 120W load) Recharge Time (to 90%) Charging Current Battery Mode ↔ Line Mode 50 1 Hz Modified sine wave N/A >95% N/A >60% 12V/4.5Ah 1 12VDC 7.9 min 6 hours N/A 4-6 ms LED Yes 100 x 143x 200 3.8kg 0~40°C <40dB No No No WxHxD Operating Temperature Noise Level USB External Slot TVSS protection LIN - 14 Line-interactive UPS UNI Z series KEY FEATURES • Ideal backup power solution for home and office • Optimized design leads to cost-saving and space-saving • Boost and buck circuit to deal with challenging power conditions • Compact size which can be easily fit with PC-related equipment • Top access of outlet makes power core connection easier 500 TYPICAL APPLICATION LIN - 15 Line-interactive UPS SPECIFICATION MODEL CAPACITY INPUT OUTPUT EFFICIENCY BATTERY TRANSFER TIME DISPLAY AUDIBLE ALARM DIMENSION NET WEIGHT ENVIRONMENT INTERFACE Input Voltage Range Frequency Range Input Wiring Output Power Factor Nominal Output Voltage Voltage Regulation (Line Mode) UNI Z 500 500VA/300W 92~142VAC 42~70 Hz Single phase with ground 0.6 120VAC N/A Voltage Regulation (Battery Mode) ±10% Frequency Range ( Battery Mode ) Output Waveform Parallel Operation Line Mode AVR Mode Battery Mode Battery Type Number of Internal Battery Rated Battery Voltage Backup Time (@ 120W load) Recharge Time (to 90%) Charging Current Battery Mode ↔ Line Mode 50±1Hz / 60±1Hz Modified sine wave N/A >95% N/A >60% 12V/4.5Ah 1 12VDC 7.9 min 6 hours N/A 4-6 ms LED Yes 100 x 143x 200 3.8kg 0~40°C <40dB No No No WxHxD Operating Temperature Noise Level USB External Slot TVSS protection LIN - 16 Line-interactive UPS BLAZER VISTA KEY FEATURES series 400 / 600 / 800 • Equipped with Boost and Buck AVR to stabilize output voltage • Built-in DC start function Easy-to-understand graphic LCD display • Smart RS232 port for remote monitoring • Easy battery replacement design • Auto self-charge under off status • Auto self-restart upon AC recovery • Surge protection for modem or phone lines • Protection against over-charge, over-discharge, over-loading 1000 / 1400 / 2000 TYPICAL APPLICATION LIN - 17 Line-interactive UPS SPECIFICATION MODEL CAPACITY INPUT OUTPUT EFFICIENCY BATTERY TRANSFER TIME DISPLAY AUDIBLE ALARM DIMENSION NET WEIGHT ENVIRONMENT INTERFACE BLAZER VISTA 800 800VA/480W Input Voltage Range Frequency Range Input Wiring Output Power Factor Nominal Output Voltage Voltage Regulation (Line Mode) Voltage Regulation (Battery Mode) Frequency Range ( Battery Mode ) Output Waveform Parallel Operation Line Mode AVR Mode Battery Mode Battery Type Number of Internal Battery Rated Battery Voltage BLAZER VISTA 400 BLAZER VISTA 600 400VA/240W 600VA/360W 162-290VAC 45~55/55~65 Hz Single phase with ground 0.6 220/230/240VAC ±15% ±10% 50/60Hz±1Hz Modified sine wave No >95% >88% >60% 12V/4.5Ah 12V/7Ah 1 1 12VDC 12V/9Ah 1 12V/7Ah 2 24VDC 12V/9Ah 2 Backup Time (@ typical PC load) 10 min 22 min 40 min 45 min Recharge Time (to 90%) Charging Current Battery Mode ↔ Line Mode 8 hours 1A 2-6 ms LCD YES 100X140X330 4.3 kg 0- 40°C <40dBA Yes/Optional Yes 10 hours 4-6 ms 6 hours 0.7A 4-8 ms 205X145X405 9.6 kg 9.7 kg WxHxD Operating Temperature Noise Level RS232/USB TVSS protection 18 min 4.97 kg BLAZER VISTA 1000 1000VA/600W 166~290VAC 45~55/55~65 Hz BLAZER VISTA 2000 2000VA/1200W ±5% 6.15 kg <45dBA LIN - 18 BLAZER VISTA 1400 1400VA/840W 9.8 kg Standby UPS APFC OFFICE KEY FEATURES series • Supports loads with APFC (Active Power Factor Correction) switch power supply with patented design 400 / 600 • Quick installation and easy to operate • Easy battery replacement • Surge protection for all receptacles • Jack for phone/model lines with surge protection • Easy-to-understand LED indicator • Protection against faults and overloading 800 TYPICAL APPLICATION APFC loads STB - 01 Standby UPS SPECIFICATION MODEL CAPACITY INPUT OUTPUT EFFICIENCY BATTERY TRANSFER TIME DISPLAY AUDIBLE ALARM DIMENSION NET WEIGHT ENVIRONMENT INTERFACE Input Voltage Range Frequency Range Input Wiring Output Power Factor Nominal Output Voltage Voltage Regulation (Battery Mode) Frequency Range ( Battery Mode ) Output Waveform Line Mode Battery Mode Battery Type Number of Internal Battery Rated Battery Voltage Backup Time (@ typical PC load) Recharge Time (to 90%) Charging Current Battery Mode ↔ Line Mode WxHxD Operating Temperature Noise Level TVSS Protection APFC OFFICE 400 400VA/200W 170~270VAC 45~55/55~65 Hz Single phase with ground 0.5 230VAC 10% 50Hz/60Hz 1Hz Modified sine wave >95% >70% 12V/4.5Ah 1 12V 9 min < 10 hours 0.5A 2-8 ms LED YES 320 x 125 x 86 mm 3.7 kg 0- 40°C <40dB Yes APFC OFFICE 600 600VA/300W APFC OFFICE 800 800VA/420W 0.525 12V/5Ah 12V/7Ah 17 min 20 min 1A 335 x 170 x 92.5 mm 5 kg STB - 02 Standby UPS MAXOFFICE Z KEY FEATURES series • UL and FCC Part 15 Class B compliant • High-frequency design and full-digital control provide optimal performance • Provides professional protections against lightning, surge, spike, brownout and blackout 425 / 625 • Battery-replaceable design enables easy maintenance • Easy-to-understand LED indicators • Pro-active audible alarms • Quick installation and easy to operate TYPICAL APPLICATION STB - 03 Standby UPS SPECIFICATION MODEL CAPACITY Input Voltage Range Nominal Frequency Input Wiring Output Power Factor Nominal Output Voltage OUTPUT Voltage Regulation (Battery Mode) Frequency Range ( Battery Mode ) Output Waveform Battery Type Number of Internal Battery BATTERY Rated Battery Voltage Backup Time (@ typical PC load) Recharge Time (to 90%) TRANSFER TIME Battery Mode ↔ Line Mode DISPLAY AUDIBLE ALARM DIMENSION WxHxD NET WEIGHT ENVIRONMENT Operating Temperature INTERFACE TVSS Protection INPUT MAXOFFICE Z 425 425VA/225W 120 VAC ± 15% 50/60Hz Single phase with ground 0.529 120VAC ± 10% 50/60 Hz ± 1Hz Modified Sine Wave 12V/2.9Ah 1 12V 5~7 min 10 hours 2-6 ms LED Yes 125X85X300 mm 2.8 kg 0- 40°C Yes MAXOFFICE Z 625 625VA/315W 0.5 12V/4.5Ah 1 7~12 min 3.5 kg STB - 04 Standby UPS MAXPOWER KEY FEATURES series 1000 • Microprocessor control guarantees high reliability • Built-in DC start function • Simple installation and easy to operate • Automatic detection of AC mains failure • Auto restart while AC recovery • Self diagnosis ensures longer battery life • Provides discharge, over-charge, and overload protection (MaxPower 1000 only) 400 / 600 TYPICAL APPLICATION STB - 05 Standby UPS SPECIFICATION MODEL CAPACITY Input Voltage Range Frequency Range Input Wiring Output Power Factor Nominal Output Voltage OUTPUT Voltage Regulation (Battery Mode) Frequency Range ( Battery Mode ) Output Waveform Line Mode EFFICIENCY Battery Mode Battery Type Number of Internal Battery BATTERY Rated Battery Voltage Backup Time (@ typical PC load) Recharge Time (to 90%) TRANSFER TIME Battery Mode ↔ Line Mode DISPLAY AUDIBLE ALARM DIMENSION WxHxD NET WEIGHT Operating Temperature ENVIRONMENT Noise Level INTERFACE TVSS Protection INPUT MAXPOWER 400 400VA/200W 90-145VAC / 170-270VAC 50Hz/60Hz Single phase with ground 0.5 110/120VAC or 220/230/240VAC 110/120VAC or 220/230/240VAC±10% 50Hz/60Hz 1Hz Modified Sinewave >95% >70% 12V/4.5Ah 1 12V 6~9 min 10 hours 2~6 ms LED Yes 80 x 230 x 176.5 mm 2.5 kg 0- 40°C <45dB Yes STB - 06 MAXPOWER 600 600VA/300W MAXPOWER 1000 1000VA/600W 0.6 12V/7Ah 1 12V/7.2Ah 2 13~20 min 30 min 3.1 kg 90.6 x 237.7 x 280 mm 6.5 kg Standby UPS DC UPS KEY FEATURES series • Ideal backup power solution for DC-powered equipment (e.g. network and telecom) • Integrated hot-swappable for battery replacement • Universal input range (80~260VAC) for global application • Microprocessor controlled for optimized performance and reliability • Supports cold-start function • Easy-to-understand LED indicators TYPICAL APPLICATION STB - 07 Standby UPS SPECIFICATION MODEL CAPACITY INPUT OUTPUT EFFICIENCY BATTERY DISPLAY AUDIBLE ALARM DIMENSION NET WEIGHT ENVIRONMENT INTERFACE Input Voltage Range Frequency Range Input Wiring Output Power Factor Nominal Output Voltage Output Voltage Range Output current Line Mode Battery Type Number of Internal Battery Rated Battery Voltage Backup Time (@ 1A discharging) Recharge Time (to 90%) Charging Current WxHxD Operating Temperature Output Terminal (7 pin) DC UPS 30W 80~260VAC 45Hz~65Hz Single phase with ground 1 12VDC 10.5~13.8VDC 2.2A max >80% 12V/7Ah 1 12VDC 340 min 4 hours 2.5A max LED Yes 120x348x80 mm 4 kg 0 – 40 ℃ 2 pin for DC output, 5 pin for dry contact STB - 08 Modular UPS GRIPOWER PRO series KEY FEATURES • Supports up to 10x15KVA UPS modules up to 150KVA output capacity • Hot-swappable UPS module with wireless design • N+X parallel redundant configuration which leaves no SPOF (Single Point of Failure) • 7” colorful touch-screen LCD • Easy installation and load expansion resulted from modular design • 3 multi-function intelligent ports which support USB, RS232, SNMP, AS400, NMC, and CMC cards • Optimized performance with >93% efficiency • Supports AC generator as AC input • Configurable battery quantity from 32 to 42 pieces per set TYPICAL APPLICATION power module MDL - 01 Modular UPS SPECIFICATION MODEL CAPACITY INPUT OUTPUT Each Module Max. Module in Parallel Input Voltage Range Frequency Range Input Wiring Current Distortion (THDi) Gripower Pro 15KVA/13.5kW 10 304-520 VAC 40-70 Hz 3-phase/4-wire + PE <5% @ 100% RCD load Output Power Factor 0.9 Nominal Output Voltage Voltage Regulation Frequency Range ( Battery & Converter Mode ) Current Crest Ratio Voltage Distortion (THDv) Output Waveform Cabinet Parallel Operation Inverter Mode Battery Mode Battery Connection Number of Battery Rated Battery Voltage Charging Current per Module Battery Mode ↔ Inverter Mode Inverter Mode ↔ Bypass Mode 353/380/400/415 VAC ±1% 50/60Hz ±0.05Hz DISPLAY AUDIBLE ALARM 2.5:1 <2% @ linear load, <4% @ non-linear load Pure sine wave N/A 93% 93% External 32~40 pcs ± Kx12 VDC (K = 16 to 20) 3.5A 0 ms 0 ms 7” touch panel LCD Yes CABINET DIMENSION WxHxD 600x2030x1000 NET WEIGHT 90KVA: 230kg / 120KVA: 265kg150KVA: 275kg 0 – 40 ℃ <62dBA Yes Supports SNMP/AS400/NMC/CMC card Yes EFFICIENCY BATTERY TRANSFER TIME ENVIRONMENT INTERFACE Operating Temperature Noise Level RS232/USB External Slot Emergency Power Off MDL - 02 3-Phase UPS 50K / 60K / 80K APUS series KEY FEATURES • 3-Phase, double-conversion online UPS • Up to 98% efficiency under High Efficiency mode results in significant energy saving 40K • Intelligent management of battery charging prolongs battery lifetime • Pre-wired for easy installation • Up to 35% smaller than similar competitive solutions • Allows dedication of more floor space to revenue producing equipment 30K 15K / 20K TYPICAL APPLICATION 3PH - 01 3-Phase UPS SPECIFICATION MODEL CAPACITY INPUT OUTPUT EFFICIENCY BATTERY Input Voltage Range Frequency Range Input Wiring Current Distortion (THDi) Output Power Factor Nominal Output Voltage Voltage Regulation Frequency Range ( Battery Mode ) Current Crest Ratio Voltage Distortion (THDv) Output Waveform Parallel Operation Inverter Mode ECO Mode Battery Type Number of Internal Battery Rated Battery Voltage Backup Time APUS 15K APUS 20K 15KVA/13.5KW 20KVA/18KW 190~478VAC 42~70Hz 3 phases + Neutral + PE <5% 0.9 380/400/415VAC 1% APUS 30K 30KVA/27KW APUS 40K 40KVA/36KW APUS 50K 50KVA/45KW 3:1 2% with linear load, <5% with non-linear load Pure sine wave Yes 94% 98% N/A N/A 384VDC / 408VDC / 432VDC N/A N/A Charging Current Battery Mode ↔ Inverter Mode Inverter Mode ↔ Bypass Mode ECO Mode ↔ Inverter Mode 5.3A 0ms 0ms 4ms Graphical LCD, 4x LEDs Yes 8A 10.6A 16A DIMENSION WxHxD (mm) 500 x 960 x 710 500 x 1230 x 710 500 x 1500 x 710 600 x 1880 x 800 NET WEIGHT (without battery) Operating Temperature Noise Level RS232/USB External Slot Emergency Power Off TBD 0-40C ≤55dB @ 75% Load Yes Yes Yes DISPLAY AUDIBLE ALARM ENVIRONMENT INTERFACE APUS 80K 80KVA/72KW 50/60 Hz 0.005Hz Recharge Time (to 90%) TRANSFER TIME APUS 60K 60KVA/54KW ≤62dB @ 75% Load 3PH - 02 ≤65dB @ 75% Load 24A 3-Phase UPS APUS Z KEY FEATURES series • Double-conversion online UPS • Up to 98% efficiency under High Efficiency mode results in significant energy saving 40K / 60K • Intelligent management of battery charging prolongs battery lifetime • Pre-wired for easy installation • Up to 35% smaller than similar competitive solutions • Delivers up to 21 minutes backup time • Allows dedication of more floor space to revenue producing equipment • UL compliant 20K / 30K TYPICAL APPLICATION 3PH - 03 3-Phase UPS SPECIFICATION MODEL CAPACITY Nominal Input Voltage Input Voltage Range Frequency Range Input Wiring Current Distortion (THDi) Output Power Factor Nominal Output Voltage Voltage Regulation OUTPUT Frequency Range ( Battery Mode ) Output Waveform Parallel Operation Inverter Mode EFFICIENCY HE Mode Battery Type BATTERY Backup Time (@ full load) Battery Mode ↔ Inverter Mode TRANSFER TIME Inverter Mode ↔ Bypass Mode ECO Mode ↔ Inverter Mode DISPLAY AUDIBLE ALARM DIMENSION WxHxD NET WEIGHT Operating Temperature ENVIRONMENT Noise Level RS232/USB INTERFACE External Slot Emergency Power Off INPUT APUS Z 20K 20KVA/16KW 208 / 220VAC APUS Z 30K 30KVA/24KW 176.8~250VAC 40~72Hz 3Ph+N+PE < 5% 0.8 208/220VAC (3-phase, 4-wire) ±1% 50Hz/60Hz Pure sine wave Up to 4 units 92% 98% 12V/9Ah 21 min 12 min 0ms 0ms TBD LCD Yes 530 x 800 x 1360 mm 476kg 0-30°C <64dB @ 1 meter Yes 2 mini-slots for SNMP/CMC/AS400 Card Yes 3PH - 04 APUS Z 40K 40KVA/32KW APUS Z 60K 60KVA/48KW 10 min 5 min 600 x 800 x 1880 mm 680kg AC Inverter HYBRID INVERTER series KEY FEATURES • • • • • • • • • Ideal energy saving solution for home/office applications Supports AC generator as input Reliable backup power supported by both PV (solar) system and battery bank Batteries can be charged by both PV system and AC input Automatically switches between 9 operation modes to optimize the energy consumption Built-in 20/35A battery charger Built-in 40A circuit breaker Built-in MPPT * for optimized PV energy harvest Compliance with CE TYPICAL APPLICATION ACI - 01 AC Inverter SPECIFICATION MODEL CAPACITY SOLAR INPUT No. of MPPT Max. Input Power Initial Feed-in Voltage Working Voltage Range Full-rating Voltage Range Input Voltage Waveform Input Voltage Range LINE MODE (AC mains are normal) Input Frequency Range Output Voltage Waveform Output Short-circuit Protection Efficiency (Line Mode) Transfer Time (AC↔DC) BATTERY MODE (AC mains are failed) BATTERY CHARGER DISPLAY PROTECTION DEGREE DIMENSION NET WEIGHT ENVIRONMENT Nominal Battery Input Voltage Min. Startup Voltage1 Output Voltage Waveform Nominal Output Voltage Output Voltage Regulation Output Frequency Efficiency Supported Battery Type Nominal Battery Voltage Min. Battery Startup Voltage1 Charger Current2 WxHxD Operating Temperature Noise Level Hybrid 5048E 5000VA/4200W 1 4500W 160VDC 130-300VDC 185-300VDC Sinewave (mains or generator) 170-280VAC (normal range) 90-280VAC (generator/wide range) 40-65Hz Same as input Built-in 40A circuit breaker >95% @R-load 10ms (normal range setting) 20ms (generator/wide range setting) 48VDC 40VDC Sinewave 230VAC 10% 50Hz / 60Hz 1Hz >95% flooded lead-acid or sealed GEL/AGM lead-acid battery 48VDC 35VDC 20/35A (user-configurable) 2 x LCD, 3 x LED indicators IP20 192x370x456 mm 17.2kg 0-45℃ 60dB Note: 1. Hybrid 5048E can only be started up with battery (>35V). 2. Total capacity of external batteries shall be no less than 100AH. ACI - 02 AC Inverter INVEREX KEY FEATURES series • Able to be configured to accept wider input voltage • Rack/Tower dual set-up design • Off-mode battery charging capability • Built-in 10 Amp super charger for up to 100Ah battery • Two-steps intelligent charging control to reduce the recharging time 500 / 1000 / 2000 TYPICAL APPLICATION ACI - 03 AC Inverter SPECIFICATION MODEL CAPACITY Input Voltage Range INPUT OUTPUT EFFICIENCY BATTERY Frequency Range Input Wiring Output Power Factor Nominal Output Voltage Voltage Regulation Frequency Range ( Battery Mode ) Output Waveform AC to AC DC to AC Battery Type Number of Internal Battery Rated Battery Voltage Charging Current Battery Mode ↔ Line Mode TRANSFER TIME DISPLAY AUDIBLE ALARM DIMENSION WxHxD NET WEIGHT Operating Temperature ENVIRONMENT Noise Level INVEREX 500 500VA/300W 170-280VAC (Normal Range) 90-280VAC (Wide Range) >40Hz Single phase with ground 0.6 220/230/240 VAC -18%~10% 50/60 Hz 0.01Hz Modified sine wave >95% >80% Lead-acid battery N/A 12V 10A 15ms typical, 40ms max LED Yes 255 X 80 X 224 mm 2 kg 0- 40°C <50dB INVEREX 1000-I 1000VA/600W INVEREX 1000-II 1000VA/600W INVEREX 2000-I 2000VA/1200W 24V 2.1 kg ACI - 04 2.3 kg 2.5 kg AC Inverter INVEREX S KEY FEATURES series • High-frequency switching technology for compact size and light weight • Pure sine wave output for wide range of applications and harsh environment 3024E • High efficient(>90%) DC-to-AC conversion minimizing energy loss • “Power Saving Mode” to conserve energy for less than 10W • Easy-to-understand graphic LCD display • Protections against Input low voltage / Overload / Short circuit / Low battery alarm/ Input over voltage / Over temperature TYPICAL APPLICATION 5048E ACI - 05 AC Inverter SPECIFICATION MODEL CAPACITY INPUT OUTPUT EFFICIENCY BATTERY TRANSFER TIME DISPLAY AUDIBLE ALARM DIMENSION NET WEIGHT ENVIRONMENT Input Voltage Range Frequency Range Input Wiring Output Power Factor Nominal Output Voltage Voltage Regulation Frequency Range ( Battery Mode ) Output Waveform Motor Load Capacity AC to AC DC to AC Battery Type Number of Internal Battery Rated Battery Voltage Charging Current Battery Mode ↔ Line Mode WxHxD Operating Temperature Noise Level INVEREX S 3024E 3000VA/2400W 90~280Vac 40~65Hz Single phase with ground 0.8 230Vac 10% 50/60 Hz 1Hz Pure sine wave 1.5HP >95% >90% Flooded/AGM/Gel lead-acid N/A 24VDC 20A 10 ms typical, 15 ms max LCD Yes 268X76X323 mm 4.9 kg 0- 45°C ≦60dB ACI - 06 INVEREX S 5048E 5000VA/4200W 170~280Vac 0.84 2.5HP VRLA/ Flooded/AGM/Gel lead acid 48VDC 20A / 35A (user configurable) 350X110X407 mm 9 kg AC Inverter INVEREX Z series KEY FEATURES • Designed for 110/120VAC AC grid system • Able to be configured to accept wider input voltage • Rack/Tower dual set-up design • Off-mode battery charging capability • Built-in 10 Amp super charger for up to 100Ah battery • Two-steps intelligent charging control to reduce the 500 / 1000 / 2000 recharging time TYPICAL APPLICATION ACI - 07 AC Inverter SPECIFICATION MODEL CAPACITY Input Voltage Range INPUT OUTPUT EFFICIENCY BATTERY Frequency Range Input Wiring Output Power Factor Nominal Output Voltage Voltage Regulation Frequency Range ( Battery Mode ) Output Waveform AC to AC DC to AC Battery Type Number of Internal Battery Rated Battery Voltage Charging Current Battery Mode ↔ Line Mode TRANSFER TIME DISPLAY AUDIBLE ALARM DIMENSION WxHxD NET WEIGHT Operating Temperature ENVIRONMENT Noise Level INVEREX Z 500 500VA/300W 90-145VAC (Normal Range) 50-145VAC (Wide Range) >40Hz Single phase with ground 0.6 220/230/240 VAC -18%~10% 50/60 Hz 0.01Hz Modified sine wave >95% >80% Lead-acid battery N/A 12V 10A 15ms typical, 40ms max LED Yes 255 X 80 X 224 mm 2 kg 0- 40°C <50dB INVEREX Z 1000-I 1000VA/600W INVEREX Z 1000-II 1000VA/600W INVEREX Z 2000-I 2000VA/1200W 24V 2.1 kg ACI - 08 2.3 kg 2.5 kg AC Inverter INVEREX HD KEY FEATURES series 1000 / 2000 • Ideal backup power solution for home / workplace • Ready for appliances such as TV, stereos and lights • High conversion efficiency (>95%) results in energy saving • High output power factor (0.72-0.8) • Easy-to-understand LCD and LED indicators • Design for both stand and wall-mounted setup • User-selectable charging current allows flexible battery configuration • Intelligent battery charging control • Protection against over-charging and over-loading TYPICAL APPLICATION ACI - 09 AC Inverter SPECIFICATION MODEL CAPACITY Input Voltage Range INPUT OUTPUT EFFICIENCY BATTERY TRANSFER TIME DISPLAY AUDIBLE ALARM DIMENSION NET WEIGHT ENVIRONMENT Frequency Range Input Wiring Output Power Factor Nominal Output Voltage Voltage Regulation Frequency Range ( Battery Mode ) Output Waveform AC to AC DC to AC Battery Type Number of Internal Battery Rated Battery Voltage Charging Current Battery Mode ↔ Line Mode WxHxD Operating Temperature Noise Level INVEREX HD 1000 1000VA/800W 170~280VAC (normal range) 90~280VAC (wide range) Single phase with ground 0.8 230Vac -18%~+10% 50/60 Hz 1% Modified sine wave >95% >80% Lead-acid battery N/A 12V 15A / 20A (user configurable) 15ms typical, 40ms max. LCD/LED Yes 220X87X252 mm 2.2 kg 0- 50°C <50dB ACI - 10 INVEREX HD 2000 2000VA/1440W 0.72 24V 10A Solar Charger Controller SOLAR MATE KEY FEATURES series 12 / 24V • High conversion efficiency • Able to supply power to DC loads for extensive applications • Built-in MPPT (Maximum Power Point Tracker) to optimize energy harvest • Supports various types of battery with tailor-made charging profiles • 3-stage battery charging control (bulk, absorption, and float charging) • Overload and lightning protection • Protection for reversed polarity of PV panel and batteries • Real-time charging status and fault events are shown by LED indicators 36 / 48V TYPICAL APPLICATION SCC - 01 Solar Battery Charger SPECIFICATION Model Battery Voltage Setting (user configurable) Input Voltage Range Rated Charging Current Load Current Max. PV Input Voltage Idle Current Consumption Over Load Protection (DC load) Bulk Charge Float Charge Over Charge Disconnection Over Charge Recovery Over Discharge Disconnection Over Discharge Reconnection Low Voltage Reconnect Low Voltage Disconnect Operating Temperature Cooling Method Protection Degree Terminal Wiring Size Dimension WxHxD Net Weight SolarMate 12/24V 12VDC 15-55VDC 40 A 15 A 55VDC <10mA 30 >5s 22.5A >20s 18.8A (de-rating) 14.6 VDC (default) 13.4 VDC (default) 14.8 VDC 13.6V 10.8V 12.3V 13± 1 VDC 11.5± 1 VDC 0-40℃ Natural cooling IP21 AWG # 8 140 x 66 X 192 mm 1.4 kg SolarMate 36/48V 36VDC 40-150VDC 24A 7A 150VDC 24VDC 29.2 VDC (default) 26.8 VDC (default) 29.6VDC 27.2V 21.6V 24.6V 26.0± 2VDC 23.0± 2VDC 14A>5s 10.5A >20s 8.8A (de-rating) 43.8 VDC (default) 40.2 VDC (default) 47.4 VDC 42.0 VDC 32.4 VDC 36.9 VDC 36.9 ± 0.3 VDC 32.4 ± 0.3 VDC 0-50℃ IP20 AWG # 20~6 220 X 311 X 124 mm 5.4 kg SCC - 02 48VDC 58.4 VDC (default) 53.6 VDC (default) 63.2VDC 56.0 VDC 43.2 VDC 49.2 VDC 49.2 ± 0.3 VDC 43.2 ± 0.3 VDC Solar Inverter GRID-TIED, SINGLE-PHASE SUNVILLE series KEY FEATURES SV1500 SV1500 SV2800 • • Transformer-less design Ideal for indoor residential installation • High conversion efficiency (up to 95%~96%) • Wide operational range for DC input voltage/current • IP43 sheet metal enclosure for SV1500~4000 • IP 65 sheet metal enclosure for SV4000A & SV6000 • Dot-matrix LCD display • Compliance with VDE0126-1-1 • Powerful communication interfaces (RS485) SV4000 TYPICAL APPLICATION SV6000 SV4000A SLI - 01 Solar Inverter SPECIFICATION MODEL CAPACITY INPUT (DC) OUTPUT (AC) EFFICIENCY GENERAL No. of MPPT 1 Max. PV Input Voltage Max. PV Input Current Initial Feed-in Voltage Working Voltage Range Full-rating Voltage Range MPPT Efficiency DC Insulation Resistance Nominal Output Voltage Nominal Output Frequency Output Wiring Max. AC Output Current Power Factor Operational Voltage Range Operational Frequency Range Current Harmonic (THDi) Maximum Weighted Average2 Topology Protection Degree Standby Consumption/night Operational Temperature Range Humidity GRID STANDARD INTERFACE DIMENSION WxDxH NET WEIGHT 1. MPPT: Maximum Power Point Tracker 2. European efficiency SV 1500 SV 2000 1500W 2000W 1 450V 500V 8.9A 10A 150V 150~405V 150~450V 200~405V 250~405V >99% >5M 230V 50/60Hz Single phase with ground 7.9A 10.5A >0.99 184~264.5V 47.5~50.2Hz <3% 95% 96% 94% 95% Transformerless IP43 < 7W / < 0.1W -20 ~ +55℃ 0 to 95%, non-condensing VDE0126-1-1 RS232 port / RS485 card slot 315X120X269mm 350X120X302mm 9.2 kg 11.5 kg SLI - 02 SV 2800 2800W SV 4000 4000W SV 4000A 4000W 13A 20A 20A SV 6000 6000W 3 750V 8.5A/tracker 125~700V 450~750V 14.3A 16.5A 20A 25.5A 94% IP65 < 8W / < 0.1W 350X136X302mm 12.8 kg 424X120X366mm 16.4 kg 434X135X386mm 19.5 kg 430X130X530mm 27 kg Solar Inverter GRID-TIED, Three-Phase SUNVILLE KEY FEATURES series SV10000 • Transformer-less design • Ideal for commercial installation • High conversion efficiency (up to 96.5%) • Wide operational range for DC input voltage/current • Sheet metal enclosure • Dot-matrix LCD display • Compliance with VDE0126-1-1 • Powerful communication interfaces (RS485) TYPICAL APPLICATION SV12500 SLI - 03 Solar Inverter SPECIFICATION MODEL CAPACITY INPUT (DC) OUTPUT (AC) EFFICIENCY GENERAL No. of MPPT1 Max. PV Input Voltage Max. PV Input Current Initial Feed-in Voltage Working Voltage Range Full-rating Voltage Range MPPT Efficiency DC Insulation Resistance Nominal Output Voltage Nominal Output Frequency Output Wiring Max. AC Output Current Power Factor Operational Voltage Range SV10000 10000W 3 800V 13A/per tracker 350V 245~720V 320~720V >99% >5M 400VAC (Line-to-Line) 50/60Hz 3-phase + N + G 17.5A >0.99 195.5~253VL-N SV12500 12500W 3 Operational Frequency Range 47.55~51.15Hz 50.15~47.55Hz Current Harmonic (THDi) Maximum Weighted Average2 Topology Protection Degree Standby Consumption/night Operational Temperature Range Humidity <3% 96.5% 95% Transformerless IP65 <30W/<3.5W -20 ~ +55℃ 0 to 95%, non-condensing VDE0126-1-1 RS232 port / RS485 card slot 585X152X454mm 34 kg GRID STANDARD INTERFACE DIMENSION WxHxD NET WEIGHT 1. MPPT: Maximum Power Point Tracker 2. European efficiency SLI - 04 245~720V 400~720V 20A 195.5~257.6VL-N 96.5% 95% 550X200X553mm 45 kg AVR HOSTA series KEY FEATURES • Provides high quality AC power to support sensitive equipment and loads • Automatically switches between buck and boost operation • Wide input voltage range • Auto-restart after AC mains’ recovery • Easy-to-read LCD and LED indicators • High efficiency design minimizes energy loss • Provides over-temperature, short-circuited protection 1000 TYPICAL APPLICATION AVR - 01 AVR SPECIFICATION MODEL CAPACITY Nominal Input Voltage Nominal Frequency Input Voltage Range Nominal Output Voltage Boost 1 Mode Voltage Boost 2 Mode Voltage Boost 3 Mode Voltage Boost 4 Mode Voltage Buck Mode Voltage Output Frequency HOSTA 1000 600VA/600W 220VAC 50Hz 120~260VAC 220 VAC Vin×1.1 Vin×1.2 Vin×1.3 Vin×1.42 Vin×0.9 Same as Input Voltage Regulation (Line Mode) +8% / -30% @330W loading Output Power Factor Line Mode 1 >98% EFFICIENCY Boost Mode Boost 1: 96%/ Boost 2: 94%/ Boost 3: 92%/ Boost 4: 84% ENVIRONMENT Buck Mode Operating Temperature Noise Level WxHxD >96% 0-50℃ <35dB 200x80x135 mm 1.95kg INPUT OUTPUT DIMENSION NET WEIGHT AVR - 02 AVR VANDA series KEY FEATURES • Provides high quality AC power to support sensitive equipment and loads • Automatically switches between buck and boost operation • Wide input voltage range • High efficiency design minimizes energy loss • Provides over-loading, over-temperature, over-voltage protection 1000 / 2000 TYPICAL APPLICATION AVR - 03 AVR SPECIFICATION MODEL CAPACITY INPUT OUTPUT EFFICIENCY ENVIRONMENT DIMENSION NET WEIGHT Nominal Input Voltage Nominal Frequency Input Voltage Range Nominal Output Voltage Boost2 Mode Voltage Boost1 Mode Voltage Buck Mode Voltage Output Frequency Voltage Regulation (Line Mode) Output Power Factor Line Mode Boost1/Boost2 Buck Operating Temperature Noise Level WxHxD VANDA 1000 1000VA/600W 220 VAC 50 Hz 165-253 VAC 220 VAC Vin×1.2 Vin×1.1 Vin×0.92 Same as Input -10%~+6% 0.6 >98% >95% >95% 0-40℃ < 50dB 111 x 135 x 215 mm 3.46 kg VANDA 2000 2000VA/1200W 4.18 kg AVR - 04 AVR IBERIS series KEY FEATURES • Provides high quality AC power to support sensitive equipment and loads 800 / 1000 / 1600 / 2000 • Automatically switches between buck and boost operation • Wide input voltage range • Easy-to-understand LED indicators • High efficiency design minimizes energy loss • Surge protection for phone/modem line TYPICAL APPLICATION AVR - 05 AVR SPECIFICATION MODEL CAPACITY INPUT OUTPUT EFFICIENCY ENVIRONMENT DIMENSION NET WEIGHT Nominal Input Voltage Nominal Frequency Input Voltage Range Nominal Output Voltage Boost Mode Voltage Buck Mode Voltage Output Frequency Voltage Regulation (Line Mode) Output Power Factor Line Mode Boost Buck Operating Temperature Noise Level WxHxD IBERIS 800 800VA/400W 120/220 VAC 50/60 Hz 80-138/180-288 VAC 120/220 VAC IBERIS 1000 1000VA/500W Same as Input 0.5 95% 92% 92% 0-40℃ < 40dB 281 mm X 90 mm X 120 mm 4.18 kg AVR - 06 IBERIS 1600 1600VA/800W IBERIS 2000 2000VA/1000W Accessory NMC Card • • • • KEY FEATURES Ideal monitoring solution enables user to monitor and control the status of UPS on web browser via internet Communicates with UPS and respond to Network Management System using SNMP (Simple Network Management Protocol) Supports RTC (Real-Time-Clock) Supports software to shutdown server or client operating system safely during the power failure NMC: Network Management Card AS400 Card • KEY FEATURES Provides voltage-free dry-contact signals for programmable controller and management system • Ideal to work with server, personal computer and workstation • Support external alarm, fault indicator, status indicator, bypass and remote shutdown CMC Card KEY FEATURES • Easy solution for remote monitoring and control • Converts the UPS RS232 signal new RS232 signal with specified address • Converts the UPS RS232 signal into RS485 signal (4-wire, full-duplex) • Provides a pair of RJ45 interface CMC: Central Monitoring Card ACC - 01 Accessory • Network Management Card Mini NMC Card • • • • KEY FEATURES Ideal monitoring solution enables user to monitor and control the status of UPS on web browser via internet Communicates with UPS and respond to Network Management System using SNMP (Simple Network Management Protocol) Supports RTC (Real-Time-Clock) Supports software to shutdown server or client operating system safely during the power failure NMC: Network Management Card Mini AS400 Card • KEY FEATURES Provides voltage-free dry-contact signals for programmable controller and management system • Ideal to work with server, personal computer and workstation • Support external alarm, fault indicator, status indicator, bypass and remote shutdown Mini CMC Card KEY FEATURES • Easy solution for remote monitoring and control • Converts the UPS RS232 signal new RS232 signal with specified address • Converts the UPS RS232 signal into RS485 signal (4-wire, full-duplex) • Provides a pair of RJ45 interface CMC: Central Monitoring Card ACC - 02 Accessory Relay Card • • • • • Provides voltage-free dry-contact signals for programmable controller and management system 5 output relay signals 1 input signal for remote on/off and UPS shutdown Configurable normal-open or normal-close signal Configurable delay time USB/RS232 Card • • • KEY FEATURES KEY FEATURES Adds USB and RS232 ports on compatible UPS Enables the remote monitoring and control of UPS via the USB and RS232 ports Compatible with monitoring software - Winpower KEY FEATURES EMP • • • Supports temperature and humidity sensors for remote environment monitoring Works with NMC card to monitor the readings using web browser and send notification when the reading exceeds pre-set limits Measures temperature from 0~70℃ and humidity from 10~90% EMP: Environmental Monitoring Probe ACC - 03 Accessory External Charger • • • • • Two models for different charging current: 8A and 20A 273V charging voltage 90% efficiency 3 LED indicators to show the charging modes and status Built-in fuse at AC input ATS • • • • • KEY FEATURES KEY FEATURES Serves as power source selector Back-feed protection Over-loading, short-circuit protection Supports RPO (Remote Power Off) Supports remote monitoring for input and output ATS: Automatic Transfer Switch ACC - 04 Accessory COMPATIBILITY MATRIX Name Part Number Titan (Vista) 1-3K Titan (Vista) 6-20K Innova 1-3K Innova 6-10K Innova Combo 10-20K Innova RT 1-6K Innova RT 10K JAGA 1-3K Gripower Pro Claire 750-3000 Spring RT 1000-3000 Name Part Number Titan (Vista) 1-3K Titan (Vista) 6-20K Innova 1-3K Innova 6-10K Innova Combo 10-20K Innova RT 1-6K Innova RT 10K JAGA 1-3K Gripower Pro Claire 750-3000 Spring RT 1000-3000 USB/RS232 Card 730-80208-00P AS400 Card (White) 730-50024-02P AS400 Card (Black) 730-80135-00P ● ● ● ● ● ● ● ● ● ● ● ● ● ● AS400SC Card 744-15568-00P Mini AS400 card 730-80141-00P Mini AS400 card 730-80197-00P Relay Card 730-80235-00 ○ ○ ● ● ● ● ● ● ● ● ● ● CMC Card 730-80118-00P Mini CMC Card 730-80100-00P ● ● ● ● ● ● ● NMC Card 730-80348-00P Mini NMC Card 730-80349-00P ● ● ● ● ● ● ● ● ● ● ● ● EMP for NMC Card 8A External Charger 12A External Charger 744-A2460-00P 730-80083-00P 730-80084-00P ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ○: not fully supported ACC - 05 • Address: No. 93 Shin Hu 3rd RD., Neihu, Taipei, 114 Taiwan •TEL: +886-2-2794-6363 • Fax: +886-2-6606-8711 • Website: www.centralion.com Copyright © 2014 Centralion Industrial Inc. All Rights Reserved.