1200 Series - Valves.Com Pte Ltd
Transcription
1200 Series - Valves.Com Pte Ltd
GLOCON GROUP Series 1200 Globe valve Pressure class ASME 150 - 600 Series 1200 Valves - Features Application The Severn Glocon Series 1200 is derived from the Series 5000 range of Globe valves. The Series 1200 benefits from more than three decades of experience in providing cost effective and easily maintained high valued quality valves in industries where consistently punishing environments have ensured a design to give rugged reliability. A wide range of construction materials offers a choice to suit the specific application, while the smooth body flow path reduces turbulence, minimising the effects of erosion and noise. Design Features u Smooth profile cast globe u Quick-change trims standard, screwed-in seat option u Wide choice of trim sizes available with low noise and anti-cavitation options u Robust parts for trouble free service and low cost of ownership u Inherently characterised trims available in linear, bi-linear, equal percentage or semi-throttle u Massive guiding u Wide choice of packing systems u Integral plug stem construction option is available u Both balanced and unbalanced trim designs available with soft seat insert options Benefits u Top-entry servicing with immediate access to plug and seat u Reduced inspection and maintenance costs u Trims compact and easy to install u Excellent flow capacity and control rangeability u Reduces potential erosion and noise problems u Reliable leakage performance, bubble tight shut off available u High interchangeability between sizes and other products u Low actuating forces required with balanced trim styles Quality Engineered u Rigorously proven on-site performance u Produced with Quality Systems certified to ISO 9001 u Compliance with PED requirements Page 3 Engineering Data Severn Glocon Series 1200 Valves General The Series 1200 range of valves were developed to provide a cost effective, reliable and easily maintained control valve capable of working in rigorous environments. The quick-change trim option provides for easily accessible seat and trim components to minimise fitting and parts replacement times. Stem guided contoured trim in both balanced and unbalanced configuration gives excellent rigidity and resistance to vibration and service wear. The valve is designed to accommodate other products within the Severn Glocon range e.g. C.C (concentric cages) low noise, and anti-cavitation trims. End connection Sizes/Types 1in (25mm) - 10in (250mm). Integral or Separable Flanges, Screwed Butt or Socket weld ends. For other consult factory. Design Standard ASME B16.34 Valve Body Ratings ASME 150 - ASME 600 Body Configurations: 2-way Globe straight Body Face to Face Dimensions ANSI/ISA 75.08 Bonnet Styles Standard, Normalising. For other styles consult factory. Standard Bonnet Packing Teflon/Chevrons and Graphite Trim Options “Quick change”, Concentric Cage(s), Multi-step, Micro Spline and Trickle Trim Inherent Trim Characteristics Equal %, Linear, Quick open. Others on request. Plug options Balanced, Unbalanced Cage/Top guided Contoured, Multi-Step Hard faced or solid hard plugs Soft seat option Plug/Seat Leakage Class ANSI/FCI 70.2. Class IV as standard, Class V with metal seat and Class VI with soft seat insert Materials of Construction A wide range of standard materials are available for both the valve pressure containing parts and trim. These include carbon and stainless steel, duplex/super duplex plus high nickel alloys. Stellite, and other hard facings/coatings are available. For full listing on materials consult factory. Paint A wide range of paint finishes are available including enamel, alkyd gloss and various epoxy finishes. Page 4 Fig.2. Series 1200 Globe Valve Direction of Flow Either direction - depending upon application. Preferred flow directions are… Contoured unbalanced (1” to 4”) : Flow under CC Trim unbalanced (upto 4”) : Flow under CC Trim balanced (6”,8”,10”) : Flow under Anti cavitation CC Trim : Flow over Flashing service : Flow over Noise abatement CC Trim (6”,8”,10”) : Flow under Actuator stability check shall be carried out as necessary. Clean Build Severn Glocon maintains high clean build standardsutilising clean build areas including Oxygen clean and a Ultra High Purity clean room. Inspection and Testing Inspection & Testing to Severn Glocon’s standard as well as to almost all international standards/ customer’s requirements. Actuation Various types of actuation are available including:Series P Linear spring pneumatic cylinder, Series N Numotor pneumatic piston, Series W Diaphragm-spring pneumatic actuator. In addition electric, hydraulic, electro hydraulic actuators and manually operated versions are available. Instruments A wide range of control instruments are available from Sever Glocon including:Positioners, Air-filter Regulators, Volume Boosters, Solenoid Valves, and Lock-up Valves. Valve Body Style Option The Severn Glocon Series 1200 valve is available in three basic body styles of either globe, angle or 3way. Many parts are interchangeable, with the exception of the valve bodies. The angles pattern has an optional venturi seat which may be specified in order to provide additional protection to the valve outlet. Fig.3. Globe Body Fig.4. Angle Body Fig.5. Three Way Body Bonnet Option Usually constructed in the same material as the valve body, selection of the bonnet design is undertaken on the basis of both the operating temperature range and the fluid media handled. A temperature range of - 190° C to 580° C is achievable. Balance Seal Fig.6. Standard Bonnet Fig.7. Normalising Bonnet Seal Retainer Fig.8. Balanced seal Installation Fig.9. Balanced Bonnet Standard Bonnet Balanced Bonnet The standard bonnet enables the forming of a deep The balanced bonnets are suitable for temperatures up to packing box together with a long guide housing, thereby 580° C when fitted with graphite packing and Graphite providing a robust and vibration resistant assembly. Teflon balancing rings and up to 232° C when fitted with PTFE rings are the standard packing up to 250° C. packing and PTFE balance seal. Normalising Bonnet Protects the packing from excessive heat or cold, which may adversely affect valve or packing performance. Application temperature range depends upon the valve and bonnet construction materials. Page 5 Standard Trim Options Available Fig.10. Unbalanced Trim Fig.11. Balanced Trim Fig.12. Hard facing options Standard duty - Normal Flows “Quick Change” balanced and unbalanced contoured trim are available. Suitable for modulating and on/off duty. u Valve Size Options Standard range up to 10ins. Large sizes consult factory. u Plug Options Balanced and unbalanced, contoured metal seated. Resilient/soft seat insert option available. Fig.13. Soft seat insert u Characteristics Available Equal %, Linear or Semi-throttle others on request. u Direction of Flow Either direction - dependent upon application. u Hard Trim Options Hard coatings/facings - Seat Area or Full Contour. Solid - Seat and/or Plug. Wide choice of materials dependent on service conditions. u Soft/Resilient Seating Soft seat insert fully supported and integral within the seat. Fig.14. Trickle Trim Standard Duty - Low Flows u The Trickle Trim/Micro Spline range provides for high rangeability and control of low flow rates. u Plug Options Unbalanced with metal to metal seating faces. u Direction of flow Either direction - dependant upon application. u Guiding Top-guided. Fig.15. CC Cage Trim Severe Service Duties Single/Multiple Concentric Cage (C.C) trims are available for higher pressure drop applications to prevent the onset of cavitation and to reduce noise levels. Page 6 Flow coefficients Cv The Cv values detailed in the tables are at the maximum rated travel and states in US units. The figures by definition are related to the flow of water (Specific gravity =1) in US Gallons per minute with a pressure drop 1 PSI. The Cv values mentioned below are nominal. Please consult with factory for process Cv over 80% of the rated Cv. Table 1: Trickle Trims Note: For valve and Trim sizes outside this range - Consult factory Page 7 Noise and Cavitation Control As a fluid passes through a restriction (normally the trim in a valve), a pressure reduction and subsequent velocity increase takes place. Immediately after the restriction, the point of lowest pressure and highest velocity is called the “vena contracta”. After which pressure recovery takes place together with a reduction in fluid velocity. The amount the fluid recovers has a great influence on the valve trim design. Fig.16. Explanation of Cavitation control using Multistage low recovery trim For liquids, if the pressure at the vena contracta goes below the liquid’s vapour pressure - bubbles are formed. If the subsequent pressure recovery to P2 (downstream pressure) exceeds the fluid’s vapour pressure - the vapour bubble collapse or implode - this is called “Cavitation”. This can occur within the valve or in the downstream pipe work. The energy dissipated can cause extensive damage to valve and pipe work. If the pressure recovery stays below the fluid’s vapour pressure then “Flashing” occurs. Multi-stage pressure let down / “Anti-cavitation” valve trim designs enable the required pressure drop across the valve to be achieved in a number of stages as illustrated in Fig.16. The velocity of the fluid through the valve has a major influence on the erosive effect of the fluid on the valve body and trim thus the control of fluid velocity and the appropriate selection of materials is critical to the valve performance and service life. Higher fluid velocities, particularly in gas service, can generate noise in the valve and pipe work - thus velocity control is major factor in containing noise emissions within acceptable limits (normally <85 dBA). Severn Glocon’s valve trim designs, engineered for a specific application, may include a combination of: u Multi-stage pressure reduction stages, u Tortuous paths - as the fluid changes direction energy is dissipated, u Flow impingement of one flow path onto another also causes energy loss, Severn Glocon can provide a trim solution having considered the process control conditions, preferred flow direction as well as initial and life cycle costs as well as application experience. Page 8 Standard dimensions and weights Fig.17. 1200 series valve fitted with W-series actuator without hand wheel Fig.18. 1200 series valve fitted with W-series actuator with side mounted hand wheel Table 4: Dimensions of Standard 1200 unbalanced valve with W-series actuator Page 9 Table 5: Dimensions of Standard 1200 balanced valve with W-series actuator Notes: 1. 2. 3. Page 10 For other sizes and rating consult factory For dimensions where unit is not indicated consider the unit as “mm”. Dimensions shown may vary depend upon options selected on actual product GLOCON GROUP Severn Glocon Ltd. Olympus Park, Quedgeley Gloucester, GL2 4NF, UK Telephone: +44(0) 845 223 2040 Fax: +44 (0) 845 223 2041 Severn Unival Ltd. Milford Buildings, Milford Street Huddersfield W Yorks, HD1 3DY, UK Telephone: +44(0) 148 451 8080 Fax: +44(0) 148 451 8087 Severn Glocon India Private Ltd. F-96/97, SIPCOT Industrial Park Irrungattukottai, Chennai 602 105 Telephone: +91 44 4710 4200 Fax: +91 44 4710 0073 Cat Ref SG 1200 rev 2009-0 Website: www.severnglocon.com The Severn Glocon policy is one of continuous improvement and the right is reserved to modify this specification bulletin without notice.
Similar documents
5000 Series - Valves.Com Pte Ltd
“Quick change”, Concentric Cage(s), Multi-labyrinth trim, Multi-step, Micro Spline and Trickle Trim Inherent Trim Characteristics Equal %, Linear, Semi-throttle. Others on request. Plug options Bal...
More informationSeries 5000 Globe Valves
– the vapour bubble collapses or implodes. This can occur within the valve, or in the downstream pipe work. The energy dissipated can cause extensive damage to both the valve and the pipe work. If ...
More informationSevern Leeds Butterfly Valves
Note: All valves are designed to meet international standards for face to face drilling and end connections. Bespoke dimensions available on request.
More information