Electric Drill Rigs Repower with 3500 Engines

Transcription

Electric Drill Rigs Repower with 3500 Engines
Electric Drill Rigs
Repower with
3500 Engines
Petroleum Division
Caterpillar Power Systems Marketing Division
Topics to Cover:
•
•
•
•
•
•
•
•
•
Electric Rig Advantages
Why DC motors
DC Drives
SCR Drives
Variable Frequency AC Drives
Oilfield Bases – old & new
Engine mounting
Ratings
Generators
Electric Drill Rig
Advantages
• Drilling area quieter with engines farther
away.
• Less danger of igniting flammable gases.
• Easier to move rig to new location.
• Electrical control of torque limits provides
better drilling control.
• However: Electrical devices may require
trained specialists.
DC Motor
Characteristics
• Variable RPM operation.
• Maximum torque at zero
RPM. Good for drawworks.
• Torque capability remains
constant over the operating
speed range.
• DC motors are 800 to 1000
HP, and 800 Volt DC.
Mudpump with
DC motors
Belt
Drive
Cooling
Fan
800 HP
DC motor
Mudpump
Drawworks with
DC Motors
1000 HP DC motors
Drawworks
DC Motor Starting
DC Drill Rig
Characteristics
• Oldest type of electric drill rig.
• DC motor speed varies with DC voltage.
• Requires a DC generator for each DC
motor.
• Non-current technology.
• Best to repower and also upgrade to SCR
technology.
DC Drill Rig Power
DC Generator
AC Generator
Replacement of engine may require moving all
generators.
DC Drill Rig
Power Flow
SCR Drill Rig
• AC Generator output changed to DC
with special Silicon Controlled
Rectifiers. (SCR)
• SCR contained in Switchgear house
– not supplied by Cat.
• 600 Volt AC rectifies to 800 volt DC.
• DC motors remain the same as on
DC rig.
DC Motor Effect on
AC Generator
• Generator Power
Factor varies with DC
motor speed. PF
varies from 0 PF to
1.0 PF
• Requires oversize
generators
• Effectively 0.6 PF
• We stamp 0.7 PF, but
generator still
oversized
D399 SCR Modules
Offshore
Land Rig
SCR Rig Power Flow
SCR Drive Advantages
• Advantages
• Less Engines/Generators Required
• Less Engines Running
• No Auxiliary Generators
• High Load on Engines
• Response on Hoisting
• Adjustable Torque Limits
• Disadvantages
• Cost
• Complexity
Variable Frequency
AC Drive
• Utilizes variable RPM AC Motors.
• Not as common yet.
• Eliminates brush maintenance of DC
motors and eliminates drawworks brake.
• AC generator does not have to be
oversize, (with “diode front-end” system).
Oilfield Bases
• Over design required to maintain
alignment and prevent vibrations.
• I-beam bases, by themselves, have not
proven successful.
• Cat history:
– 18 inch semi-boxed beams.
– 21 inch boxed beams.
– Tubular “base-within-a-base” design.
A Day in the Life of an
Oilfield Power Module
Rig transportation between jobs can cause misalignment.
So also can hull flexing on offshore drill rigs.
Original 18 inch Cat
base for DC drill rigs
Some versions
welded the
engine deep oil
pan into the base.
These cannot be
repowered with
3500 series.
(Some did have
3 point mounting.)
Special deep rails
18 inch Base
18-Inch Base
3500 Repower
easily accomplished
3500 Repower cannot
be accomplished
because of added
mounting blocks.
21-Inch Boxed
Beam Base
• Boxed beam provides alignment and
resistance to vibration.
• 3 point mounting isolates package from
offshore rig hull movement.
• 21 inch base was rarely used on land rigs
because it was large, heavy and hard to 3
point mount.
– Very easy to repower with 3500 series.
3-Point Mount Isolates
External Forces
3-Point Mount
4-Point Mount
21-Inch Cat
Oilfield Base
21-inch main beams.
Cross beams & boxing.
Engine supported on standard
10-inch rails.
Entire base 3-point mounted to offshore rig.
Caterpillar
21-Inch Base
Deep Oil Pan
Shallow Oil Pan
Easily accommodates either deep or shallow oil pans.
Works with 6.25 bore and 3500 series.
3500A on 21-Inch Base
Mounting
Blocks
3-Point
Mount
Replacing D399 only requires repositioning
mounting blocks.
Base-Within-A-Base
• Consists of an inner and an outer base.
• Inner base holds engine-to-generator
alignment.
• Built-in 3-point mount between inner and
outer bases.
• Two different outer bases used:
– Land:
• 25-, 30-, and 40-foot length
– Offshore:
• Lighter and lower than 21-inch base.
Base-Within-A-Base
Two Bases Included
Inner tubular base removes 10-inch mounting rails.
Inner
Tubular
Base
Walkways
3-Point
Mounts
Outer
Base
3500B Land Rig
Power Module
Walkways
Tubular inner base
3-point mount
(not visible)
30-foot outer base
3512B SCAC
Land Power Module
30-Foot Base
Dual Core Radiator
SR4B Generator
3500B Offshore
Power Module
Inner Base
Outer Base
Drip Pan
Built-in Spring Isolators
Oil Drain
Unique Application
Inner base only sold for
select applications.
Special trailer power units.
Repower
Considerations
D399 land rig has 7.12-inch
wider oil pan than 3500 series.
Base inserts would have to
be added between 3500 series
oil pan and existing inner base.
Has been done.
D398 repower with 3512 or
3508 would require drilling
matching holes into the old
inner base. Has been done.
Candidate For 3512
Land Rig Repower!
Additional
Considerations
Exhaust
Roof
Ladders
Lights
Power Cables
Land SCR HP Ratings
– 1200 RPM
•
•
•
•
•
•
•
•
•
•
•
•
•
D300
3516B
3516
3512B
3512
3512
D399
3512
3508B
D398 912
3508
D379
3412E
3500A
3500B
1855
1804
1476
1434
1321
1215
950
912
860
610
587
Offshore SCR HP
Ratings – 1200 RPM
•
•
•
•
•
•
•
D300
3516B HD
3516B
3512B
D399 (SCAC)
D399 (JWAC)
D398 (JWAC)
1325
1215
912
3500B
2150
1855
1476
Offshore Engine
Room Complexity
3516B Offshore
Package
JW Heat Exchanger
Aftercooler Heat Exchanger
Tilt Angle
Requirements
25 degree capability
for optional oil pan.
Most Jackups: 10 Degrees
Floaters: 15 Degrees
Emergency Gen Sets: 22.5 Degrees
Caterpillar Viscous
Dampened Coupling for
2 Bearing Generators
Driving
Element
Rubber
Boot and
Silicon
Lubricant
Driven
Element
SR4B Oilfield
Generators
• Oversize compared to EPG applications
• Two bearing, independently supported
• Form wound / VPI insulation
– Class H
– Resist electrical stresses
• No voltage regulator
• 10 OHM copper RTDs
• 800 units in operation
• SR4B spec sheet and EDS
Cat SR4B Oilfield
Generator
• Reduced winding
temperature rise rating
• Provides safety margin for
winding heating due to
electrical waveform distortion
• 80 C instead of 105 C rise
• Oversized for 0.7 or 0.6 PF
rating
• Protects generator rotor from
overheat at low PF
• Capable of operating at even
lower PF
Waveform Distortion
Recommended Oilfield
Generator kVA Sizing
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
HP
kVA
(1200 RPM)
860
1000
915
1200
1210
1500
1321
1500
1435
1750
1476
1750
1804
2150
1855
2150
2150
2500
(1500 RPM)
1180
1500
1381
1500
1749
1900
(oversize) PF
0.61
0.55
0.58
0.63
0.58
0.60
0.60
0.62
0.61
0.56
0.65
0.65
Drill Rig Performance
(Generator Sizing)
• Oversize generators for the engine capability
improves hoisting performance.
• Oversize generators allows operation of
mudpumps over a broader operating stroke
range.
• This can be verified with a rig power analysis
performed for deep drilling (low PF), shallow
drilling (high PF), and hoisting (variable PF).
• Analysis needs to consider local rig operating
customs.
SR4B Generator Form
Wound Stator – Class H
Insulation
SR4B Generator
Exciter & Space for PMG
SR4B Generator with
Generator Air Filter
Generator Special Items
• Custom Quotes Possible
• Quote Kato or Baylor as requested
• Factory packaging warrants
generator alignment.
• Note: Published TMI SR4B
generator exciter data is for 0.8 PF.
Lower power factor requires more
voltage regulator capacity.
ƒ
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Partial Consist:
3512B for Land SCR
Rig Service
3512 Diesel Engine
1476 BHP
3512B Diesel Oilfield Engine
Exhaust Elbow
Spark Arresting Muffler 12 “
Engine Governor Control – 0 to 200 ma
Generator SR4B, 1750 kVA
Cable Access Box, RH
Radiator Group – 46 CVS, 140 F
Radiator Mounting Group
Belt Guard
Blower Fan Group
Fan Drive Group
Pulley Group
Fumes Disposal
Alarm Relay Panel
3512B
HP01476
512DZ36
EXCEL08
MUFSA03
GOVPG08
OGNSEPD
CAACBX1
RAD4621
RADMNT1
BLTGD1
FANB006
FDV0037
FANPL10
FUMDIS4
CQR item
Alarm Relay Panel
Provides remote alarm & additional alarm interfaces
Partial Consist: 3516B
for Offshore SCR Rig
Service
ƒ
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
3516 Diesel Engine
1855 BHP
3516B Diesel Oilfield Engine
Marine Society Arrangement
Exhaust Elbow
Spark Arresting Muffler
Engine Governor Control – 0 to 200 ma
Generator SR4B, 2150 kVA
Cable Access Box, RH
ABS – Engine
ABS – Generator
Fuel Cooler
Alarm Relay Panel
Engine Wiring J-Box
Centrifugal Oil Filter
Grid Switch
3516B
HP01855
516DY11
ABSCONV
EXCEL09
MUFSA02
GOVPG08
OGNSEP1
CAACBX1
MSABS23
CQR item
CQR item
CQR item
CQR item
CENTOF0
CQR item
Grid Switch &
Centrifugal Oil Filter
Additional
Requirements
• Marine classification societies.
– ABS – per the above partial consists
– DNV, LR – certified coupling, Premium
Wiring Harness
• Computer system interfacing
Partial Consist: 3516B HD
for Offshore SCR Rig Service
ƒ
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
3516 Diesel Engine
2150 BHP
3516B HD Diesel Oilfield Engine
Oversize Mounting System – 3 point base
Heat Exchanger System
Marine Society Arrangement
Exhaust Elbow
Spark Arresting Muffler
Engine Governor Control – 0 to 200 ma
Kato Generator, 2500 kVA
Coupling Hub
High Tilt Oil Pan
ABS – Engine
ABS – Generator
Fuel Cooler
Alarm Relay Panel
Engine Wiring J-Box
Centrifugal Oil Filter
Grid Switch
3516B
HP02150
516DY07
CQR item
CQR item
ABSCONV
EXCEL13
MUFSA01
GOVPG08
CQR item
COUHUB1
CQR item
MSABS24
CQR item
CQR item
CQR item
CQR item
CENTOF0
CQR item
Oversize Mounting System
& Heat Exchangers, High
Tilt Oil Pan
Semi-submersibles
Require 15 Degree Tilt
Oil Pans
3516B HD Applications
2150 BHP
• Achieve 10,000 HP in 5 engines.
– Large land rigs and some jackups
• Repower large competitive engines
– Less expensive than 3600 series.
– Roots blown EMDs
• 16-645 is 2200 HP roots blown
– Alco, Fairbanks Morse, SACM
• Savings in weight, space, noise, emissions,
new cost and reduced operational cost.