Air Maintenance/ Compressor Assembly 30.22
Transcription
Air Maintenance/ Compressor Assembly 30.22
30.22 FIRE PROTECTION PRODUCTS – DEVICES Air Maintenance/ Compressor Assembly SERIES 7C7 For FireLock NXT™ Series 768 Dry Valves, Series 769 Deluge and Preaction Valves, Series 764 Alternate Valves. Note: The Series 7C7 Air Maintenance/Compressor Assembly is designed for systems that do not require an accelerator to achieve the required system pressure performance. If an accelerator is required, a tank-mounted compressor with a regulated air maintenance device should be used. SERIES 7C7 PRODUCT DESCRIPTION The Series 7C7 Air Maintenance/Compressor assembly consists of a riser-mounted compressor, Series 757P Air Maintenance Device and flexible hoses for installation. It is designed to ensure the valve system can achieve operational air pressure within 30 minutes of discharge, in accordance with NFPA 13 requirements (7.2.6.2.2). The Series 757P Air Maintenance Device is UL Listed and FM Approved. The Series 7C7 Assembly is available with 1/6, 1/3 and 1/2 horsepower compressors depending upon the system requirements. COMPRESSOR CAPACITIES The engineer/system designer is responsible for sizing the compressor so that the entire system is charged to the required air pressure within NFPA guidelines (30 minutes). DO NOT oversize the compressor to provide more airflow. An oversized compressor will slow down or possibly prevent valve operation. Hp Nominal AC Voltage/Hz (+/- 10%) 1/6 110/60 1/3 110/60 1/3 220/50 1/3 220/50 1/3 220/60 1/2 110/50 1/2 110/60 3/4 220/50 3/4 220/60 3/4 220/50 3/4 220/60 Pressure psi/Bar 18 1.2 18 1.2 18 1.2 18 1.2 18 1.2 18 1.2 18 1.2 18 1.2 18 1.2 18 1.2 18 1.2 Time Minutes 30 30 30 60 30 30 30 30 30 60 60 Capacity WITH AutoVent gallons/m3 Capacity WITHOUT AutoVent gallons/m3 175 0.7 375 1.4 160 0.6 450 1.7 370 1.4 660 2.5 780 3.0 600 2.3 700 2.7 1200 4.5 1375 5.2 275 1.1 525 2.0 235 0.9 660 2.5 400 1.5 670 2.5 830 3.1 675 2.5 775 2.9 1350 5.0 Amp Draw 2.1 Amps 4.4 Amps 6.6 Amps 3.8 Amps 1525 5.8 NOTE: Refer to the charts on the following pages for minimum required fill capacities to 13 psi/0.9 Bar. Low air alarms will clear at 13 psi/0.9 Bar. In addition, these charts contain higher capacities to 18 psi/1.2 Bar that are not shown in the table above. JOB/OWNER CONTRACTOR ENGINEER System No._______________________________ Submitted By_____________________________ Spec Sect________________Para____________ Location_________________________________ Date____________________________________ Approved________________________________ Date____________________________________ www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G 30.22_1 30.22 FIRE PROTECTION PRODUCTS – DEVICES Air Maintenance/ Compressor Assembly SERIES 7C7 ASSEMBLY DIMENSIONS A A A B B B C C C D D Series 7C7 - 1/2HP Compressor D Series 7C7 - 1/3HP Compressor Series 7C7 - 1/6HP Compressor Series 7C7 - 1/2HP Compressor Pipe Size A B C D 1 1/2” 2” 2 1/2” & 76.1 3” 4” 6” & 165.5 8” 14.5 14.77 15.03 15.36 15.94 16.98 18.01 4.8 4.8 4.8 4.8 4.8 4.8 4.8 6.55 6.55 6.55 6.55 6.55 6.55 6.55 15.54 15.54 15.54 15.54 15.54 15.54 15.54 Series 7C7 - 1/3HP Compressor Pipe Size A B C D 1 1/2” 2” 2 1/2” & 76.1 3” 4” 6” & 165.5 8” 14.53 14.78 15.04 15.36 15.88 16.98 18.02 5.00 5.00 5.00 5.00 5.00 5.00 5.00 6.55 6.55 6.55 6.55 6.55 6.55 6.55 15.38 15.38 15.38 15.38 15.38 15.38 15.38 Series 7C7 - 1/6HP Compressor Pipe Size A B C D 1 1/2” 2” 2 1/2” & 76.1 3” 4” 6” & 165.5 8” 14.53 14.78 15.04 15.36 15.88 16.98 18.02 4.60 4.60 4.60 4.60 4.60 4.60 4.60 6.55 6.55 6.55 6.55 6.55 6.55 6.55 15.38 15.38 15.38 15.38 15.38 15.38 15.38 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 30.22_2 REV_G 30.22 FIRE PROTECTION PRODUCTS – DEVICES Air Maintenance/ Compressor Assembly SERIES 7C7 ASSEMBLY PERFORMANCE (1/2 HP Compressor) - For use with FireLock NXT Series 768 Dry, Series 764 Alternate wet/dry and 769 Deluge and Preaction systems. Estimated Time to Reach Various Pressures Series 7C7 with 1/2-hp (110 VAC, 50 Hz) Compressor and No Auto Vent Estimated Time to Reach Various Pressures Series 7C7 with 1/2-hp (110 VAC, 50 Hz) Compressor and Auto Vent 50 50 40 40 35 13 psi 13 psi Time (minutes) Time (minutes) 18 psi 18 psi 45 30 25 20 30 20 15 10 10 5 0 50 100 150 200 250 300 350 400 450 500 550 600 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 650 700 750 800 850 900 950 1000 System Size (gallons) System Size (gallons) Estimated Time to Reach Various Pressures Series 7C7 with 1/2-hp (110 VAC, 60 Hz) Compressor and No Auto Vent Estimated Time to Reach Various Pressures Series 7C7 with 1/2-hp (110 VAC, 60-Hz) Compressor and Auto Vent 18 psi 40 50 18 psi 35 13 psi 40 25 Time (minutes) Time (minutes) 30 20 15 13 psi 30 20 10 10 5 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 0 25 75 125 175 225 275 325 375 425 475 525 575 625 675 725 775 825 875 925 975 1025 1075 1125 1175 1225 System Size (gallons) System Size (gallons) www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G 30.22_3 30.22 FIRE PROTECTION PRODUCTS – DEVICES Air Maintenance/ Compressor Assembly SERIES 7C7 ASSEMBLY PERFORMANCE (1/3 HP Compressor) - For use with FireLock NXT Series 768 Dry, Series 764 Alternate wet/dry and 769 Deluge and Preaction systems. Estimated Time to Reach Various Pressures Series 7C7 with 1/3-hp (110 VAC) Compressor and No Auto Vent Estimated Time to Reach Various Pressures Series 7C7 with 1/3-hp (110 VAC) Compressor and Auto Vent 60 13 psi 18 psi 30 18 psi 50 13 psi 20 Time (minutes) Time (Minutes) 40 30 10 20 10 0 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 System Size (gallons) 750 System Size (Gallons) Estimated Time to Reach Various Pressures - 220-volt Option Series 7C7 with 1/3-hp (220-240 VAC, 50-Hz) Compressor and Auto Vent 1.2 Bar 60 Estimated Time to Reach Various Pressures - 220-volt Option Series 7C7 with 1/3-hp (220 - 240 VAC, 50 Hz) Compressor and No AutoVent 0.9 Bar 70 1.2 Bar 60 50 50 0.9 Bar Time (minutes) Time (minutes) 40 30 40 30 20 20 10 0 10 0.2 0.6 1.0 1.4 1.8 2.2 2.6 0 3.0 0 0.5 1.0 System Size (cubic meters) 1.5 2.0 2.5 Estimated Time to Reach Various Pressures - 220-volt Option Series 7C7 with 1/3-hp (220-240 VAC, 60-Hz) Compressor and Auto Vent Estimated Time to Reach Various Pressures - 220-volt Option Series 7C7 with 1/3-hp (220 - 240 VAC, 60 Hz) Compressor and No Auto Vent 60 60 1.2 Bar 1.2 Bar 50 50 0.9 Bar 30 0.9 Bar 40 Time (minutes) 40 Time (minutes) 3.0 System Size/Volume (cubic meters) 30 20 20 10 10 0 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 0 0.5 2.8 1.0 1.5 2.0 2.5 3.0 System Size/Volume (cubic meters) System Size (cubic meters) NOTE: Refer to the following page for charts reflecting the 220-volt 1/3-hp option. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 30.22_4 REV_G 30.22 FIRE PROTECTION PRODUCTS – DEVICES Air Maintenance/ Compressor Assembly SERIES 7C7 ASSEMBLY PERFORMANCE (1/6 HP Compressor) - For use with FireLock NXT Series 768 Dry, Series 764 Alternate wet/dry and 769 Deluge and Preaction systems. Estimated Time to Reach Various Pressures Series 7C7 with 1/6-hp (110 VAC) Compressor and Auto Vent Estimated Time to Reach Various Pressures Series 7C7 with 1/6-hp (110 VAC) Compressor and No AutoVent 70 18 psi 30 18 psi 13 psi 60 13 psi 20 Time (minutes) Time (Minutes) 50 40 30 10 20 0 50 10 100 150 200 250 300 350 400 System Size (gallons) 0 50 100 150 200 250 300 350 400 System Size (Gallons) www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G 30.22_5 30.22 FIRE PROTECTION PRODUCTS – DEVICES Air Maintenance/ Compressor Assembly SERIES 7C7 exploded view drawing series 7c7 air maintenance compressor assembly with 1/2-hp compressor 15 24 14 1 25 19 To Actuator Trim 4 14 26 2 17 5 23 10 7 18 12 16 6 3 11 13 8 22 9 20 21 Bill of Materials Item Qty. Description 1 1 Compressor 2 1 Mounting Bracket 3 1 Series 757P Air Maintenance Trim Assembly with Pressure Switch 4 1 Stainless Steel Braided Flex Hose (½-inch NPT Male x Female) 5 2 Split Hanger for ½-inch Pipe 6 2 Hose Clamp 7 1 Close Nipple (¼-inch NPT) 8 3 Close Nipple (½-inch NPT) 9 3 90° Female Elbow (½-inch NPT) 10 2 Hex-Head Bolt (3⁄8 - 16 x 5⁄8-inch Long) 11 4 Lock Washer (5⁄16 inch) 12 2 Lock Washer (3⁄8 inch) 13 4 Hex Nut (¼ - 20 UNC) 14 2 Straight Conduit Connector (½-inch) 15 1 Liquid-Tight Conduit (½ inch x 9½ inches Long) 16 1 14 AWG, 3-Strand Cable (25 inches Long) 17 3 #8 U-Style Wire Connector 18 1 Identification Tag 19 1 Compressor Air Intake Filter 20 1 Nipple (½-inch NPT x 10 inches Long) 21 1 Nipple (½-inch NPT x 4½ inches Long) 22 1 Union (½-inch NPT) 23 1 Reducing Bell (½-inch NPT x ¼-inch NPT) 24 1 14 AWG Grounded Cord with Plug (5½ feet Long)* 25 1 Strain Relief Connector* 26 1 Identification Label* * NOTE: Items 24 - 26 apply only to the CSA version Exaggerated for Clarity www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 30.22_6 REV_G 30.22 FIRE PROTECTION PRODUCTS – DEVICES Air Maintenance/ Compressor Assembly SERIES 7C7 exploded view drawing series 7c7 air maintenance compressor assembly with 1/3-hp compressor 16 15 25 10 1 To Actuator Trim 26 4 18 7 19 27 2 5 17 20 21 11 13 6 24 3 8 12 14 22 23 9 Exaggerated for Clarity Bill of Materials Item Qty. Description 1 1 Compressor 2 1 Mounting Bracket 3 1 Series 757P Air Maintenance Trim Assembly with Pressure Switch 4 1 Stainless Steel Braided Flex Hose (½-inch NPT Male x Female) 5 2 Split Hanger for ½-inch Pipe 6 2 Hose Clamp 7 1 Close Nipple (¼-inch NPT) 8 2 Close Nipple (½-inch NPT) 9 3 90° Female Elbow (½-inch NPT) 10 4 Hex-Head Bolt (5⁄16 - 18 x ¾-inch Long) 11 2 Hex-Head Bolt (3⁄8 - 16 x 5⁄8-inch Long) 12 4 Lock Washer (5⁄16 inch) 13 2 Lock Washer (3⁄8 inch) 14 4 Hex Nut (5⁄16 - 18) 15 2 Straight Conduit Connector (½ inch) 16 1 Liquid-Tight Conduit (½ inch x 9½ inches Long) 17 2 14 AWG, 3-Strand Cable (25 inches Long) 18 3 #8 U-Style Wire Connector 19 1 Identification Tag 20 1 Reducing Bell (½-inch NPT x ¼-inch NPT) 21 1 Nipple (½-inch NPT x 1½ inches Long) 22 1 Nipple (½-inch NPT x 5½ inches Long) 23 1 Nipple (½-inch NPT x 9½ inches Long) 24 1 Union (½-inch NPT) 25 1 14 AWG Grounded Cord with Plug (5½ feet Long)* 26 1 Strain Relief Connector* 27 1 Identification Label* * NOTE: Items 25 - 27 apply only to the CSA version exploded view drawing series 7c7 air maintenance compressor assembly with 1/6-hp compressor 26 15 17 18 1 8 To Actuator Trim 25 24 16 4 19 2 5 12 10 7 20 6 22 14 3 13 9 11 23 21 5 Exaggerated for Clarity Bill of Materials Item Qty. Description 1 1 Compressor 2 1 Mounting Bracket 3 1 Series 757P Air Maintenance Trim Assembly with Pressure Switch 4 1 Stainless Steel Braided Flex Hose (½-inch NPT Male x Female) 5 2 Split Hanger for ½-inch Pipe 6 2 Hose Clamp 7 3 90° Female Elbow (½-inch NPT) 8 1 Close Nipple (¼-inch NPT) 9 2 Close Nipple (½-inch NPT) 10 2 Hex-Head Bolt (3⁄8 - 16 x 5⁄8-inch Long) 11 3 Hex-Head Bolt (#10 - 32 x ½-inch Long) 12 2 Lock Washer (3⁄8 inch) 13 3 Lock Washer (#10) 14 1 Identification Tag 15 1 Straight Connector, Flexible Cord 16 1 Connector, Flexible Cord 17 1 Liquid-Tight Conduit (½ inch x 11½ inches Long) 18 3 #8 U-Style Wire Connector 19 1 Reducing Bell (½-inch NPT x ¼-inch NPT) 20 1 Nipple (½-inch NPT x 1½ inches Long) 21 1 Nipple (½-inch NPT x 9 inches Long) 22 1 Union (½-inch NPT) 23 1 Nipple (½-inch NPT x 5 inches Long) 24 1 Identification Label* 25 1 Strain Relief Connector* 26 1 14 AWG Grounded Cord with Plug (5½ feet Long)* * NOTE: Items 24 - 26 apply only to the CSA version www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G 30.22_7 30.22 FIRE PROTECTION PRODUCTS – DEVICES Air Maintenance/ Compressor Assembly SERIES 7C7 electrical information INCOMING POWER SUPPLY (REFERENCE COMPRESSOR DATA PLATE) DANGER • Only qualified electricians should connect incoming power to the Series 7C7 Air Maintenance/Compressor Assembly. L1 L2 • To reduce the risk of electric shock, check the electrical source for proper grounding. Failure to follow these instructions could result in death or serious personal injury. LINE LOAD LOAD L1 T1 T2 LINE L2 T1 Ground Connection T2 MOTOR ELECTRICAL CONNECTION NOTE: NEMA 1 Enclosure - intended only for indoor use Only qualified electricians should make the connection to the incoming power supply. All wiring shall be completed in accordance with requirements of the local authority having jurisdiction and any applicable electrical codes. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. WARNING WARNING • This product must be installed by an experienced, trained installer, in accordance with the instructions provided with each valve. These instructions contain important information. Failure to follow these instructions may result in serious personal injury, property damage, or valve leakage. If you need additional copies of this product literature or the valve installation instructions, or if you have any questions about the safe installation and use of this device, contact Victaulic Company, P.O. Box 31, Easton, PA 18044-0031 USA, Telephone: 001-610-559-3300. For complete contact information, visit www.victaulic.com 30.22 4847 REV G UPDATED 02/2013 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 30.22