OlympiaTheatre–TechnicalSpecifications–RevisedJanuary2016
OlympiaTheatreTechnical
Specifications
UpdatedJanuary2016
PleasenotethattheStageisstillcurrentlyundergoing
worksandTechSpecwillbeupdatedonanongoing
basis.Emailtechnicaldirector@olympia.ieformost
currentchanges.
OlympiaTheatre–TechnicalSpecifications–RevisedJanuary2016
TechnicalDepartmentStaffDetails
MatthewCregan–TechnicalDirector–technicaldirector@olympia.ie
0864118412
FeargaO’Doherty–Stage/Productionmanager–fearga@olympia.ie
DillonKeane–ChiefLX–dillon@olympia.ie
LeoCooney–DepLX–leo@olympia.ie
LloydOosthuizen–DepStage–Lloyd@olympia.ie
NormanVerso–FOHSound–norman@olympia.ie
JohnChisholm–MonitorEngineer
Allstaffcanbecontactedviathebelownumber-
+35318972125
OlympiaTheatre–TechnicalSpecifications–RevisedJanuary2016
STAGEDETAILS
Stage/ProductionManager–FeargaO’Doherty–fearga@olympia.ieor+353
18972125
STAGEDIMMENSIONS
ProsceniumOpening10.50M
Pros.Height(BottomofIron)5.94M
SafetyCurtain1.17MUpstageoffrontedge
DepthofStage10.36M
HeightofStagefromAuditorium1.52M
WidthofPit1.52M
FlyingHeight6.70M
StageRake1:25
SUSPENSIONEQUIPTMENT
15XDoublePurchaseCounterweightBars12.2mlong.MaxUDLPerbar136kg.
4x12mLightingTruss(30cm)
***Pleasenoteatpresentthemaxoverallloadingofgridis1500KG,thisisfor
bothcounterweightbarsandalsotrussing***(DUETOBEUPGRADEDMID
2016)
DRAPESANDMASKING
1xRedHouseTabs,c/wcentreopening,suspendedfromsinglepurchase
counterweightbar.
2xBlacktabs12.2Mx6.67M
4xBlackBorder13Mx3M
6xBlackLegs7Mx3M
STAGING
6x8x4AluminumStageRisersc/w1foot,2footand3footlegsforeach.
ClampstojoinareavailableasareSkirtsandCarpet.
HEIGHTACCESS
1xTallescope
1xZargesLadder
2x2mA-FrameLadder
OlympiaTheatre–TechnicalSpecifications–RevisedJanuary2016
ARTISTACCOMMODATION
5Dressingroomsareavailabletoanyproduction.Theyarelockableand
alarmed.
DressingRoom1–ProductionOffice
DressingRoom2–Max4people
DressingRoom3–Max4peoplewithtoiletandshowers.
DressingRoom4–Max5people
DressingRoom5–Max5people
ShowerandToiletfacilitiesareavailableonboththe1stand2ndfloor.
Ourwardroberoomhasasink,WashingMachine,TumbleDryerandIroning
Facilities.
OlympiaTheatre–TechnicalSpecifications–RevisedJanuary2016
LIGHTINGSPECIFICATIONS
HouseLX–DillonKeane–Dillon@olympia.ieor+35318972125
3x72wayETCSensor3DimmingRacksc/wthrupowermodulesbrokendown
asfollows.
210x3kwCircuits–Thesecanbeeithersettodimmingorhotpowerandare
presentedonstagelevel,flyfloorandfrontofhouseinnewfacilitypanels,
terminatinginbothSocapexand16AmpCeeForm.
6x5kwCircuits–Thesecanbeeithersettodimmingorhotpowerandare
presentedonstagelevelandflyfloorinnewfacilitypanels,terminatinginboth
16AmpCeeFormand32AmpCeeForm.
EachFacilitypanelhas2xDMXtielinesand2datatielinesgoingbacktonew
Dimmerandpatchroom@flyfloorlevel.
Anextensivestagerewirehastakenplaceattheendof2015includingDMX
processing,ArtNetandConsoleupgrades,seebelow.
LIGHTINGCONSOLES
2xAvolitesArenaConsoles(1asBackupeitherStageorFrontofHouse)
1xETCIonc/wFaderwing.
***Controlfromfrontofhouseisvia8UniversesofDmxthroughaProplex
ArtNetNodeinDimmerRoom,and8xDMXBuffers***
GENERICLIGHTINGSTOCK
36xSource4Zoom15/30750Watt
12xSource426Degreec/wTopHatandIris(theseareafixedlightingposition
inFOHBOXES)
24xRobertJuliat310HF1200Watt(additionalavailablefromGaietyTheatre
subjecttoavailability)
24xThomasParCanCP62Lamp
8x8CellMolephay
MOVINGLIGHTS
12xRobe575Spot
8xChauvet560ZWash
6xChauvet419Wash
OlympiaTheatre–TechnicalSpecifications–RevisedJanuary2016
TYPICALHOUSELXRIGASOFJANUARY2016
AboveisanexampleofthestandardhouseLXhang.Duetoconservationlistings,
itisNOTpermittedtoerectanystructuresontheproscarchorontheadvance
auditoriumpillars.6x26DegreeSource4’shavebeenprovidedinthehouse
boxeseachside,c/wTopHatandIris.Theseareafixedpositionandcannotbe
reriggedorhavealternativefixturesriggedintheirplace.
FOLLOWSPOTS
2xLycianmediumthrowfollowspots
(Scheduledforupgradepostsummer2016)
EFFECTS
1xUnique2Hazer
1x10mx6mwhiteLEDstarclothavailablebypriorarrangementfromour
sistertheatretheGaiety.
OlympiaTheatre–TechnicalSpecifications–RevisedJanuary2016
TOURINGLXPOWER
NewtouringLXmainspanelislocatedMSR
2x32Amp3Phase
1x63Amp3Phase
1x125Amp3Phase
1x400Amp3Phase(terminatedinpowerlockinbottom)
MISC
1x12WayRackMountedMotorControlc/wPendantremote.
COMMUNICATIONS
1xCanfordTecProBaseSystem,terminatedinfacilitypanelsaroundthe
theatre,c/w8beltpacksandheadsets.
1x12waycuelightsystem,terminatedinfacilitypanelsaroundtheatreand
controlledvianewstagemanagersdesk.
OlympiaTheatre–TechnicalSpecifications–RevisedJanuary2016
RIGGING
ONSTAGERIGGINGPOINTS–Therearethreewoodenbeamsrunningupstageto
downstage,withonebeamoncentreandtheothers10feeteithersideofcentre.
MaxUDLperbeamis500kgwithamaxpointloadof300kg.Pleaseremember
thatatpresentmaxloadingofgridincludingflyingsystemis1500kg.
FRONTTRUSSPOINTS–Thefronttrussisinapresetpositionandis11mlong
ofLitecQX40,powdercoatedblack.Thereisamaxloadingof200kgperpoint.
Largertrussisavailableuponrequest.Minimum1weeknoticerequiredfor
changingoftruss.
OlympiaTheatre–TechnicalSpecifications–RevisedJanuary2016
SOUNDSPECIFICATIONS
FRONTOFHOUSESYSTEM
Console–AvidProfile
Control/Processing–
2xXTADP224x-overforMainSystem
1xXTADR226forFlownSystem
2xXTADR224x-overforDelays
SYSTEM
4XL-AcousticsSB218perside(8total)
ForSeatedshows–
3XL-AcousticsArcsperside(6total)
ForStandingshows–
6XL-AcousticsArcsperside(12total)
5xL-AcousticsArcsflownoncentre
6xL-AcousticsMTD115BforDelays
2xNexoPS8forinfills
AMPS
LabgruppenforL-AcousticsArcsandSB218’s
CrestforL-AcousticsMTD115B
MONITORSYSTEM
Console–YamahaM7
Wedges–
12xSSEMB4Active1’x15”,1’x2”
12xCrest7301’s
Drumfill–
2xWedgeasabove
1xEVMT2Bass(2x18)
1xCrest6001
Sidefills–
2x3wayactivesidefills
2xL-AcousticsArcsPerside
2xL-AcousticsdV–Subsperside
LabgruppenAmps
XTADP226x-over
OlympiaTheatre–TechnicalSpecifications–RevisedJanuary2016
Mics-
8xShureSM58
8xShureSM57
6xShureBeta57A
4xSennheiser504
4xShureSM81
4xShureSM98
2xShureKSM27
1xShureBeta52
1xShureSM91
1xBeyerM88
1xEVPL20
5xSCVD12MKDDIBoxes
6xBSSAR133DIBoxes
2xKlarkTeknikDIBoxes
3xCountrymanDIBoxes
20xTallBoomStands
15xShortBoomStands
Additional–
40xChannelsBSSActiveSplitters
TOURINGSOUNDPOWER
NewtouringsoundpowerislocatedMSL
6x16AmpSinglePhase
2x32AmpSinglePhase
1x63AmpSinglePhase
1x63AmpThreePhase
ForfurthersoundinfopleasecontactNormanVerso–norman@olympia.ieor
+35318972125