OrthoLAB - orthodyne
Transcription
OrthoLAB - orthodyne
www.orthodyne.be SPECIFICATIONS Temperature control indicators: Column oven: room temperature 8 °C — 400 °C Accuracy ± 0.1 °C Injector: room temperature 8 °C — 400 °C Accuracy ± 0.1 °C Detector: room temperature 8 °C — 400 °C Accuracy ± 0.1 °C The number of temperature settings 8 channels Temperature programming 8 commands Heating rate 1 °C — 40 °C Cooling speed: within 7 minutes (350 °C to 50 °C) Performance of workstation: Communication interface RS232 / USB interface High accuracy 24-bit high accuracy A/D Resolution ± 1uv Input level range -5 mv to + 1 v Sampling frequency Maximum 20 times per second Dynamic range 106 Integral sensitivity 1μv·sec Linearity <±0.1%. Reproducibility 0.06%. ORTHOLAB GAS ANALYSER The first LABORATORY GC With ORTHODYNE PHILOSOPHY Size (W) 655 mm x (H) 500 mm x (D) 480 mm deep Weight ± 48 kg Power supply 220 V ± 10 %, 50 Hz, Power ≥ 2kW Side Top 655 mm ORTHODYNE S.A. Rue des Technologies, 23 B-4432 ALLEUR - BELGIUM 480 mm Phone : +32-4-247 91 06 Fax : +32-4-263 09 79 E-Mail : sales@orthodyne.be 1501475 © www.ultrapetita.com • 0495 807 112 480 mm Front 500 mm Dimensions Other parameters: The ORTHOLAB Gas Chromatograph represents a true combination of analytical instrumentation and computer technology. This design and implementation make ORTHOLAB a unique instrument. DIAPHRAGM VALVES MULTI-OVENS DIAPHRAGM VALVES Orthodyne engineers have the expertise and experience to design a customer flow system for the ORTHOLAB GC using a choice of 4, 6 and 10 port diaphragm valves. All valves are manufactured with the highest quality to have a very reliable analytical circuit. The ORTHOLAB GC can virtually accommodate any configuration for optimum separation and precise quantification. Valves can be manual or pneumatical actuated. This diaphragm valve is designed for trouble-free use in applications requiring minimal maintenance and maximum lifetime, making it an ideal choice for the process industry, automated lab analysers, or continuous-monitoring analyses. OVENS AND COLUMNS The ovens can accept capillary columns or packed columns. Each oven can be adjusted to the correct temperature to optimise the chromatographic analysis. PDD DETECTOR DETECTORS Whether it is for Pharmaceutical, Petrochemical, Air Separation or Industrial fields, ORTHOLAB meets your stringent needs. The ORTHOLAB GC can accommodate different detectors. VALVES CUSTOMISED MANUFACTURING Orthodyne engineers work closely with the customer to design chromatographic system for their application. When it comes to specific applications, Orthodyne has also significant expertise in the development and design of gas sampling systems for conventional GC. OVEN The oven has a front door for easy access to columns. Overheat protection circuit. CUSTOMISED ANALYSIS N2O 5.96 CO2 5.39 N2 2.85 Ar 1.85 C2H2 7.09 H2 0.82 322.000 CH4 4.44 383.000 [mv] 261.000 200.000 139.000 4.80 5.60 6.40 7.20 8.00 [min] 337.000 257.000 177.000 97.000 17.000 0.00 1.10 2.20 3.30 4.40 5.50 6.60 7.70 8.80 9.90 11.00 [min] DATA ACQUISITION SYSTEM The powerful GC 9560 software, in conjunction with a Windows based PC system, allows the instrumentation technicians to create methods, design custom reports, view calibration curves and process data sequences. Data Management has never been easier. Choice of Detectors 4.00 co 8.98 3.20 CO2 5.95 2.40 N2 3.12 1.60 H2 0.84 0.80 CH4 5.10 417.000 [mv] 78.000 0.00 TCD Thermal Conductivity Detector – Selective for all gaseous and volatile compounds, non destructive. FID Flame Ionisation Detector – Selective for Organic Analysis. PDD Pulsed Discharge Detector – Selective for Universal response, non radioactive. FPD Flame Photometric Detector – Selective for Sulphur & Phosphorous compounds. Other detectors available on request Fast, reliable results for all your laboratory analyses. ORTHOLAB Gas Chromatograph is the first system that delivers the same reliability, high performance and quality results as our standard Process systems.