Airtècnics

Transcription

Airtècnics
AIRTECNICS: The Air Curtain Specialist
Founded in 1986 and placed in Castellar del Vallès (Barcelona),
Airtècnics has a large experience producing air curtains, air handling
units, fan boxes, fan filter units, axial fans, centrifugal fans and other
special and OEM equipment.
We export our products to more than 45 countries worldwide.
Besides our own production, Airtècnics distributes a wide range of
HVAC products, mostly produced by Rosenberg Group companies.
Loyal to our commitments regarding our customers, our products
fulfill the highest standards of quality criteria.
We are proud of our highly qualified team composed by master
engineers, designers, specialized technicians and skilled
professionals, ready to assist you in any questions you may have
in design, installation or service maintenance requirements.
Be sure that Airtècnics or our worldwide distributors network will give
you the right solution for any air curtains application.
• Air curtains market leading
• Producing +20 years
• Exporting +45 countries
• Catalogue +25 languages
www.airtecnics.com
Find more information and our distributors list in our specialized
air curtain websites:
Latvian
www.gaisaaizkari.com
Catalan www.cortinesaire.com
Lithuanian
www.orouzuolaidos.com
Czech
www.vzduchoveclony.com
Norwegian
www.luftporter.com
Danish
www.lufttaepper.com
Polish
www.kurtynapowietrzna.com
Dutch
www.luchtgordijnen.com
Portuguese www.cortinadear.com
English
www.dooraircurtain.com
Romanian
www.perdeledeaer.com
Finnish
www.ilmaverho.com
Russian
www.vozdushnyezavesy.com
French
www.rideauxdair.com
Serbian
www.vazdusnezavese.com
German www.luftschleieranlagen.net
Slovenian
www.zracnezavese.com
Greek
Bulgar
Airtècnics headquarters in Castellar del Vallès (Spain)
• Experimented R+D+i
• Continuous improving
• Complete range, all applications
• University knowledge collaboration
www.vazdushnizavesi.com
www.aerokourtines.com
Spanish
www.cortinasdeaire.es
Hungary www.legfuggonyok.com
Swedish
www.luftridaer.com
Italian
Turkish
www.havaperdeleri.eu
www.barrieradaria.com
The Rosenberg Group
Airtècnics is from 1993 fully integrated in the Rosenberg Group, an
organization specializing in the design, manufacturing and distribution
of equipments and components of ventilation and air conditioning with
factories, subsidiaries and agencies in more than 50 countries.
Founded in 1981, with a total of 1.400 employees, 14 production
sites on 4 continents, as well as 4 development centres.
Rosenberg develops, produces and distributes its products worldwide.
Through a combination of human know how and innovative production
technology Rosenberg products achieve a quality which meets the
highest requirements.
Rosenberg headquarters in Künzelsau (Germany)
2
AIR CURTAINS
The new and attractive generation of Airtècnics air curtains are the ideal
solution to maintain a comfortable interior climate in commercial outlets
and public buildings that need to keep their doors open.
The end result is more customers and an increase in sales. Airtècnics
air curtains are a protection from the cold and heat, repel gusts of wind
and minimize dust, fumes, pollution and insects entering the building.
Airtècnics air curtains create an air stream layer over the doorway
and act as an invisible barrier which efficiently divides the inside
environment from the outside one. Therefore, it substantially reduces
heating and cooling costs up to 80%, while increasing employees and
clients comfort.
In order to obtain these advantages it’s very important to choose the
appropriate air curtain. Factors such as interior drop, strong winds,
the door’s location, stairs between floors, opposite doors, and the
installation height have to be taken into consideration.
For shops, Airtècnics air curtains allow a clear view of the inside of the
shop, welcoming the client to enter easily and freely.
Decorative
Standard
Heat Pump
Revolving Doors
Air curtains
Air curtains
Air curtains
Recessed
Air curtains
Our expert consultants with their extensive experience are at your
disposal to help you choose.
Air curtains
Industrial
Air curtains
Advantages
MAINTAIN:
PROTECT FROM:
- Heating levels
- Refrigeration
- Air conditioning
- Comfort
- Clean atmosphere
- Cold winter temperatures
- Hot summer temperatures
- Car fumes
- Dust in the air
- Pollution
- Bad smells and odours
- Insects
Selection of an air curtain
To select an air curtain the following factors have to be kept in mind:
-
-
-
-
-
-
-
-
-
-
The height of the installation measured from the discharge diffuser to the floor
The width of the door
The location of the building to determine the level of protection needed against weather conditions
If the building has several doors in the same, different or opposite facade
If the building has several stores connected by escalators
Pressure differences between the inside and outside of the building
Door characteristics: if always open, if automatic door, manual door, revolving door, etc.
Characteristics of the ventilation and air conditioning installation
Voltage and electrical power availability
Type of business, style and decoration of the premises
www.dooraircurtain.com
3
WIDE RANGE
Applications
Model
Kind
Optima
Optima Wireless
Recessed Optima
Windbox
Recessed Windbox
Smart
M, ECM
Zen
Rund
Deco
Dam
G
Recessed Dam
Windbox DX
Invisair
Rotowind
ECG
Variwind
Recessed Compact (A)
Kool (A)
Triojet
Maxwell
Max
A
Heating
E P
Common Applications
• •
Kiosks, Fast Food and small sized shops. Restaurants and places with
usually closed door or automatic door when low pedestrian flow.
2,2 - 2,8 m
• • •
Small and medium sized premises. Restaurants, shops and places
with a medium and high pedestrian flow. Creation of different
environment zones. Protection against dust, fumes, pollutants and
insects. False ceiling installations. Isolation and sealing of smoking
areas.
2,5 - 3,5 m
• • •
Up to 1,8 m
Minibel
Windbox
Recommended
Installation
Height (*)
3,0 - 3,8 m
• • •
3,2 - 4,2 m
• • •
2-3m
L
4-5m
XL
5-7m
4-6m
•
• • •
• • •
•
•
• • •
Medium and large sized premises with a high pedestrian flow.
Protection against dust, fumes, pollutants and insects. Cold rooms.
False ceiling installations. Isolation and sealing of smoking areas.
Industrial doors for large cold rooms and freezers with very low
temperatures or problems with ice production.
Medium and large sized premises with a high pedestrian flow.
Industrial doors. Protection against dust, fumes, pollutants and
insects. Cold rooms. False ceiling installations.
Industrial doors. Loading dock. Vertical Installation to one side of the
door or at each side of the door. Horizontal Installation.
(*) The maximum height of installation depends on the conditions of the premises. Contact us to clear up your queries or doubts.
(A) Air Only, (E) Electrical Heating, (P) Water Coil Heating LPHW.
4
INDEX | Air Curtains Wide Range For All Applications
6
MINIBEL
WINDBOX L, XL
30-31
High pressure for commercial and
large industrial doors 4 - 7 m
Economical for openings up to 1,8 m
OPTIMA WIRELESS
7
INVISAIR
Recessed in column or bulkhead
For commercial doors 2,2 - 2,8 m
32-33
vertical or horizontal 2,5 - 4,2 m
8
OPTIMA
For commercial doors 2,2 - 2,8 m
ROTOWIND
34-35
VARIWIND
36-37
Tailor made for revolving doors
2,5 - 4,2 m
RECESSED OPTIMA
9
For commercial doors 2,2 - 2,8 m
recessed installation in false ceiling
WINDBOX M, ECM, G, ECG
10-11
Tailor made variable length
VP or VW construction 2,5 - 4,2 m
High pressure for commercial
and industrial doors 2,5 - 4,2 m
RECESSED WINDBOX
12-13
KOOL
38
TRIOJET SYSTEM
39
MAXWELL
40
High velocity for cold store
and freezer doors 2,5 - 4,2 m
High pressure for commercial doors
recessed installation in false ceiling 2,5 - 4,2 m
SMART
14-15
Combination system with multijets
for large cold stores 2 - 3 m
Decorative high pressure for commercial
and industrial doors 2,5 - 4,2 m
ZEN
Customizable design with bespoke
panels for commercial doors 2,5 - 4,2 m
16-17
Large industrial doors
vertical or horizontal 4 - 6 m
MAX
RUND
18-19
DECO
20-21
Decorative cylindrical for vertical or
horizontal installation 2,5 - 4,2 m
RECESSED COMPACT
Decorative with aluminium profiles
for commercial doors 2,5 - 4,2 m
DAM
22-23
High pressure for commercial doors
with front panel 2,5 - 4,2 m
RECESSED DAM
24-25
Compact recessed for commercial
and industrial doors 2,5 - 4,2 m
HEAT PUMP AIR CURTAINS
26-29
Energy saving and very low consumption
technology for commercial doors 2,5 - 4,2 m
41
Large industrial doors
vertical or horizontal 4 - 6 m
42
Air only compact recessed for commercial
and industrial doors 2,5 - 4 ,2m
ACCESSORIES
SPECIAL OPTIONS
43
Valves, sensors, etc.
REGULATION
44-47
SUPPORTS
48-49
Basic regulation: standard controls
Advanced regulation: Clever control
Controllers and regulation
Standard or Tailor made
5
MINIBEL | Air Curtains For Commercial Doors
• Self-supporting casing construction made of galvanized steel plate, finished in
structural epoxy-polyester painting white colour RAL9016 as standard. Other
colours are available on request.
• Anodized aluminium outlet vanes, airfoil shaped.
• Compact axial fans, low noise level.
• “E” type with electrical shielded element. “A” type without heating, air only.
• Integrated switch for ventilation and heating control.
• Cable connection 1,5m length, integrated.
• Wall support included.
Model
MINIBEL 600 A
MINIBEL 600 E
MINIBEL 900 A
MINIBEL 900 E
6
Airflow
m3/h
Power
1x230V
kW
Noise
Level
dB(A)
Weight
kg
Recommended
Height up to
m
Price
euros
420
420
630
630
2,5
3,2
46
46
47
47
9
10
12,5
13,5
1,8
1,8
1,8
1,8
315
384
414
498
OPTIMA WIRELESS | Air Curtains For Commercial Doors
• Self-supporting casing construction made of galvanized steel plate, finished in
structural epoxy-polyester painting white colour RAL9016 as standard. Other
colours are available on request.
• Micro-perforated inlet grille with filter functions and easy service. It does not need
prefilter.
• Anodized aluminium outlet vanes, airfoil shaped.
• Low noise twisted cross-flow fans driven by a 2-speed external rotor motor.
• “E” type with electrical shielded elements, two stages with integrated regulation.
“A” type without heating, air only.
• Included regulation with infrared remote control and inbuilt keypad with leds.
AIR ONLY
Model
OPT W 1000 A
OPT W 1500 A
OPT W 2000 A
Airflow
m3/h
1500
2150
2900
Noise
Level
(5 m)
dB(A)
35/50
36/51
38/53
Weight
kg
17,5
25,5
33
Recom.
Height
Instal.
m
2,8
2,8
2,8
Airflow
m3/h
1500
1500
2150
2150
2150
2900
2900
Electrical
Heating
Capacity (*)
kW
4/6
3,8/5,6
6/9
3,8/5,6
6/9
5,6/11,3
5,6/11,3
Electrical
Heating
Voltage
V
400Vx3
230Vx1
400Vx3
230Vx1
230Vx1
400Vx3
230Vx1
Electrical
Heating
Current
A
5,8/8,7
16,5/24,5
8,7/13
16,5/24,5
26/39,1
8,1/16,3
24,5/49,1
ELECTRICAL HEATED
Model
OPT W 1000 E
OPT W 1000 E230
OPT W 1500 E
OPT W 1500 E230-6
OPT W 1500 E230-9
OPT W 2000 E
OPT W 2000 E230
Price
euros
688
826
1.234
Noise
Level
(5 m)
dB(A)
35/50
35/50
36/51
36/51
36/51
38/53
38/53
Weight
kg
20,5
20,5
27,5
27,5
27,5
42
42
Recom.
Height
Up to
m
2,8
2,8
2,8
2,8
2,8
2,8
2,8
Price
euros
862
862
1.032
1.032
1.032
1.596
1.596
Accessories
IR CONTROL
SPT2
SPWR
SLB
SPCT
RNG 20/30
7
OPTIMA | Air Curtains For Commercial Doors
• Self-supporting casing construction made of galvanized steel plate, finished in
structural epoxy-polyester painting white colour RAL9016 as standard. Other
colours are available on request.
• Micro-perforated inlet grille with filter functions and easy service. It does not need
prefilter.
• Anodized aluminium outlet vanes, airfoil shaped.
• Low noise twisted cross-flow fans driven by a 2-speed external rotor motor.
• “P” type with water heated coil. “E” type with electrical shielded elements, two
stages with integrated regulation. “A” type without heating, air only.
• Includes Plug&Play control with 7m RJ45 cable and infrared remote control.
Optional: Clever control (programmable, automatic, intelligent, energy saving,
Modbus RTU for BMS…).
AIR ONLY
Model
OPT 1000 A
OPT 1500 A
OPT 2000 A
Airflow
m3/h
1500
2150
2900
Noise
Level
(5 m)
dB(A)
35/50
36/51
38/53
Weight
kg
17,5
25,5
33
WATER HEATED P86
Recom.
Height
Instal.
m
2,8
2,8
2,8
Price
euros
819
957
1.365
Model
OPT 1000 P
OPT 1500 P
OPT 2000 P
Airflow
m3/h
1400
2100
2750
Heating
Capacity
80/60ºC
kW
8,2
12,7
16,7
Noise
Level
(5 m)
dB(A)
37/51
38/52
40/54
Weight
kg
20,5
27,5
37,5
Recom.
Height
Up to.
m
2,8
2,8
2,8
Price
euros
1.116
1.350
1.878
Water heated: connection pipes 1/2’’ female. 2 rows coil.
ELECTRICAL HEATED
Model
OPT 1000 E
OPT 1000 E-9
OPT 1000 E230
OPT 1500 E
OPT 1500 E230-6
OPT 1500 E230-9
OPT 2000 E
OPT 2000 E230
Airflow
m3/h
1500
1500
1500
2150
2150
2150
2900
2900
Electrical
Heating
Capacity (*)
kW
4/6
6/9
3,8/5,6
6/9
3,8/5,6
6/9
5,6/11,3
5,6/11,3
Electrical
Heating
Voltage
V
400Vx3
400Vx3
230Vx1
400Vx3
230Vx1
230Vx1
400Vx3
230Vx1
Electrical
Heating
Current
A
5,8/8,7
8,7/13
16,5/24,5
8,7/13
16,5/24,5
26/39,1
8,1/16,3
24,5/49,1
Noise
Level
(5 m)
dB(A)
35/50
35/50
35/50
36/51
36/51
36/51
38/53
38/53
Weight
kg
20,5
21,5
20,5
27,5
27,5
27,5
42
42
Recom.
Height
Up to
m
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
Price
euros
1.133
1.212
1.198
1.328
1.388
1.417
2.010
2.184
SPCT
RNG 20/30
(*) Under request other electrical heating capacities may be supplied.
Special Finishes
Painting according RAL chart
or metallic
Accessories
IR CONTROL CLEVER
8
TD-NE
IN-NE-II
DC
V-S/M
V-T
SPT2
SPWR
SLB
RECESSED OPTIMA | Recessed Air Curtains For Commercial Doors
• Self-supporting casing construction made of galvanized steel plate, ready to be
installed recessed in a false ceiling.
• Inlet grille (free of maintenance) made with aluminium profiles and blow-out
nozzle, integrated in a single white frame colour RAL 9016. Other colours are
available on request.
• Anodized aluminium outlet vanes, airfoil shaped.
• Low noise twisted cross-flow fans driven by a 2-speed external rotor motor.
• “P” type with water heated coil. “E” type with electrical shielded elements, two
stages with integrated regulation. “A” type without heating, air only.
• Includes Plug&Play control with 7m RJ45 cable and infrared remote control.
Optional: Clever control (programmable, automatic, intelligent, energy saving,
Modbus RTU for BMS…).
AIR ONLY
Model
RO 1000 A
RO 1500 A
RO 2000 A
Airflow
m3/h
1700
2200
3200
Noise
Level
(5 m)
dB(A)
35/50
36/51
38/53
Weight
kg
24
34
44,5
Recom.
Height
Up to
m
2,8
2,8
2,8
WATER HEATED P86
Price/Unit
euros
1.080
1.254
1.782
Model
RO 1000 P
RO 1500 P
RO 2000 P
Airflow
m3/h
1450
2175
2850
Heating
Capacity
80/60ºC
kW
8,3
13
17,1
Noise
Level
(5 m)
dB(A)
37/51
38/52
40/54
Recom.
Height
Up to
m
2,8
2,8
2,8
Weight
kg
26,5
37,5
49
Price
euros
1.377
1.647
2.295
Water heated: connection pipes 1/2’’ female. 2 rows coil.
ELECTRICAL HEATED
Model
RO 1000 E
RO 1000 E-9
RO 1000 E230
RO 1500 E
RO 1500 E230-6
RO 1500 E230-9
RO 2000 E
RO 2000 E230
Airflow
m3/h
1700
1700
1700
2200
2200
2200
3200
3200
Electrical
Heating
Capacity (*)
kW
4/6
6/9
3,8/5,6
6/9
3,8/5,6
6/9
5,6/11,3
5,6/11,3
Electrical
Heating
Voltage
V
400Vx3
400Vx3
230Vx1
400Vx3
230Vx1
230Vx1
400Vx3
230Vx1
Electrical
Heating
Current
A
5,8/8,7
8,7/13
16,5/24,5
8,7/13
16,5/24,5
26/39,1
8,1/16,3
24,5/49,1
Noise
Level
(5 m)
dB(A)
35/50
35/50
35/50
36/51
36/51
36/51
38/53
38/53
Weight
kg
26
27
26
37,5
37,5
37,5
53,5
53,5
Recom.
Height
Up to
m
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
Price
euros
1.353
1.473
1.413
1.624
1.685
1.731
2.427
2.562
(*) Under request other electrical heating capacities may be supplied.
Special Finishes
Inlet and outlet grille painting according to
RAL chart or metallic
Accessories
IR CONTROL
CLEVER
TD-NE
IN-NE-II
DC
V-S/M
V-T
SPANG-SIL
SPWR
SLB
SPCT
9
WINDBOX M,ECM,G,ECG |
High Pressure Air Curtains
For Commercial And Industrial Doors
• Self-supporting casing construction made of galvanized steel plate, finished in
structural epoxy-polyester painting white colour RAL9016 as standard. Other
colours or stainless steel are available on request.
• Micro-perforated inlet grille with filter functions and easy service. It does not need
prefilter.
• Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side.
• Double-inlet centrifugal fans driven by an external rotor motor and low noise level.
5-speed selector. “EC” models assembled with very low consumption efficiency fans.
• “P” type with water heated coil. “E” type with electrical shielded elements, three
stages with integrated regulation. “A” type without heating, air only. Optional
expansion DX coil.
• Includes Plug&Play control with 7m RJ45 cable and infrared remote control.
Optional: Clever control (programmable, automatic, intelligent, energy saving,
Modbus RTU for BMS…).
AIR ONLY
Model
M 1000 A
M 1500 A
M 2000 A
M 2500 A
M 3000 A
ECM 1000 A
ECM 1500 A
ECM 2000 A
ECM 2500 A
ECM 3000 A
G 1000 A
G 1500 A
G 2000 A
G 2500 A
G 3000 A
ECG 1000 A
ECG 1500 A
ECG 2000 A
ECG 2500 A
ECG 3000 A
Airflow
m3/h
1800
2700
3600
4500
5400
1840
2760
3680
4600
5520
2400
3200
4800
5600
6400
2700
3600
5400
6300
7200
ELECTRICAL HEATED
Model
M 1000 E
M 1500 E
M 2000 E
M 2500 E
M 3000 E
ECM 1000 E
ECM 1500 E
ECM 2000 E
ECM 2500 E
ECM 3000 E
G 1000 E
G 1500 E
G 2000 E
G 2500 E
G 3000 E
ECG 1000 E
ECG 1500 E
ECG 2000 E
ECG 2500 E
ECG 3000 E
10
Airflow
m3/h
1800
2700
3600
4500
5400
1840
2760
3680
4600
5520
2400
3200
4800
5600
6400
2700
3600
5400
6300
7200
Power
Fans
230Vx1
kW
0,212
0,318
0,424
0,530
0,636
0,132
0,198
0,264
0,330
0,396
0,642
0,856
1,284
1,498
1,712
0,225
0,300
0,450
0,525
0,600
Electrical Heating
Capacity
400Vx3-50Hz
kW
3/6/9
4/8/12
6/12/18
6/12/18
8/16/24
3/6/9
4/8/12
6/12/18
6/12/18
8/16/24
5/10/15
7,5/15/22,5
10/20/30
10/20/30
10/20/30
5/10/15
7,5/15/22,5
10/20/30
10/20/30
10/20/30
Current
Fans
230Vx1
A
0,94
1,41
1,88
2,35
2,82
1,14
1,71
2,28
2,85
3,42
2,85
3,80
5,70
6,65
7,60
1,95
2,60
3,90
4,55
5,20
Power
Fans
230Vx1
kW
0,212
0,318
0,424
0,530
0,636
0,132
0,198
0,264
0,330
0,396
0,642
0,856
1,284
1,498
1,712
0,225
0,300
0,450
0,525
0,600
Noise Level
(5 m)
dB(A)
55
56
57
58
59
56
57
58
59
60
57
58
59
60
61
61
62
63
64
65
Current
Fans
230Vx1
A
0,94
1,41
1,88
2,35
2,82
1,14
1,71
2,28
2,85
3,42
2,85
3,80
5,70
6,65
7,60
1,95
2,60
3,90
4,55
5,20
Noise Level
(5 m)
dB(A)
55
56
57
58
59
56
57
58
59
60
57
58
59
60
61
61
62
63
64
65
Weight
kg
31
46
58
72
86
31
46
58
72
86
43
51
80
84
95
43
51
80
84
95
Weight
kg
37
57
75
94
112
37
57
75
94
112
52
63
100
106
120
52
63
100
106
120
Recommended
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
4,2
Recommended
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
4,2
Price
euros
1.317
1.635
1.983
2.472
3.501
1.536
1.944
2.415
3.018
4.071
1.548
1.884
2.451
2.940
3.972
1.848
2.268
3.066
3.658
4.980
Price
euros
2.148
2.556
3.015
3.807
5.328
2.358
2.865
3.447
4.359
5.934
2.415
2.868
3.828
4.728
5.943
2.703
3.235
4.440
5.448
6.918
WINDBOX M,ECM,G,ECG |
WATER HEATED
Model
Airflow
m3/h
1660
2490
3320
4150
4980
1720
2580
3440
4300
5160
2250
3000
4500
5250
6000
2550
3400
5100
5950
6800
M 1000 P
M 1500 P
M 2000 P
M 2500 P
M 3000 P
ECM 1000 P
ECM 1500 P
ECM 2000 P
ECM 2500 P
ECM 3000 P
G 1000 P
G 1500 P
G 2000 P
G 2500 P
G 3000 P
ECG 1000 P
ECG 1500 P
ECG 2000 P
ECG 2500 P
ECG 3000 P
P86
Heating
Capacity
80/60ºC
kW
9,17
14,26
20,65
26,92
33,24
9,38
14,58
21,12
27,53
40,00
11,04
16,02
24,92
31,16
37,35
11,89
17,29
26,86
33,63
40,34
P64
Heating
Capacity
60/40ºC
kW
8,56
13,69
18,26
22,12
28,37
8,77
14,02
18,70
23,33
29,05
10,42
15,47
22,29
26,61
32,10
11,27
16,77
24,14
28,84
34,81
High Pressure Air Curtains
For Commercial And Industrial Doors
P54
Heating
Capacity
50/40ºC
kW
8,52
14,34
18,65
24,32
29,77
8,74
14,71
19,13
24,95
30,54
10,56
16,37
23,15
28,76
34,03
11,50
17,86
25,24
31,38
37,16
Power
Fans
230Vx1
kW
0,428
0,642
0,856
1,070
1,280
0,132
0,198
0,264
0,330
0,396
0,642
0,856
1,284
1,498
1,712
0,225
0,300
0,450
0,525
0,600
Current
Fans
230Vx1
A
1,90
2,85
3,80
4,75
5,70
1,14
1,71
2,28
2,85
3,42
2,85
3,80
5,70
6,65
7,60
1,95
2,60
3,90
4,55
5,20
Noise
Level
(5 m)
dB(A)
56
57
58
59
60
56
57
58
59
60
57
58
59
60
61
61
62
63
64
65
Weight
kg
35
53
69
86
103
35
53
69
86
103
50
59
92
96
109
50
59
92
96
109
Recom.
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
4,2
P86
Price
euros
1.602
1.977
2.409
3.126
4.311
1.809
2.274
2.811
3.657
4.902
1.830
2.223
2.853
3.570
4.779
2.112
2.580
3.441
4.266
5.757
P64
Price
euros
1.686
2.070
2.565
3.345
4.614
1.890
2.367
2.967
3.873
5.175
1.911
2.310
3.000
3.774
5.061
2.196
2.670
3.579
4.482
6.048
P54
Price
euros
1.821
2.229
2.754
3.642
4.983
2.025
2.526
3.156
4.170
5.544
2.046
2.469
3.189
4.071
5.430
2.331
2.829
3.768
4.779
6.417
Water heated: connection pipes P86 and P64 are 2x3/4” female (male if lateral pipes), P54 2x1” male. P86 2 rows coil, P64 3 rows coil, P54 4 rows coil.
Installation Options
Telescopic
outlet kit
M, G
euros
175
210
250
277
644
Model
1000
1500
2000
2500
3000
Telescopic
inlet kit
M, G
euros
177
213
253
279
729
Telescopic false
ceiling kit
M, G
euros
352
423
503
556
1.373
Telescopic false ceiling
kit + plenum
M, G
euros
558
652
779
870
2.363
Plenum
surface mounting
M, G
euros
206
229
276
314
990
Special Finishes
Painting according RAL chart
or metallic
Stainless steel casing AISI 304
Accessories
IR CONTROL
CLEVER
CH-5HW-NE
TD-NE
IN-NE-II
DC
V-S/M
V-T
AFS-INS
SPWR
SLB/SPCT
SPF-MG
SPJ2-MG
11
RECESSED WINDBOX |
High Pressure Recessed Air Curtains
For Commercial And Industrial Doors
• Self-supporting casing construction made of galvanized steel plate, ready to be
installed recessed in a false ceiling.
• Inlet grille (free of maintenance) made with aluminium profiles and blow-out
nozzle, integrated in a single white frame colour RAL 9016. Other colours are
available on request.
• Anodized aluminium outlet vanes, airfoil shaped, adjustable in both directions.
• Double-inlet centrifugal fans driven by an external rotor motor and low noise level.
5-speed selector. “EC” models assembled with very low consumption efficiency
fans.
• “P” type with water heated coil. “E” type with electrical shielded elements, three
stages with integrated regulation. “A” type without heating, air only. Optional
expansion DX coil.
• Includes Plug&Play control with 7m RJ45 cable and infrared remote control.
Optional: Clever control (programmable, automatic, intelligent, energy saving,
Modbus RTU for BMS…).
AIR ONLY
Model
RM 1000 A
RM 1500 A
RM 2000 A
RM 2500 A
RECM 1000 A
RECM 1500 A
RECM 2000 A
RECM 2500 A
RG 1000 A
RG 1500 A
RG 2000 A
RG 2500 A
RECG 1000 A
RECG 1500 A
RECG 2000 A
RECG 2500 A
Airflow
m3/h
1800
2700
3600
4500
1840
2760
3680
4600
2400
3200
4800
5600
2700
3600
5400
6300
ELECTRICAL HEATED
Model
RM 1000 E
RM 1500 E
RM 2000 E
RM 2500 E
RECM 1000 E
RECM 1500 E
RECM 2000 E
RECM 2500 E
RG 1000 E
RG 1500 E
RG 2000 E
RG 2500 E
RECG 1000 E
RECG 1500 E
RECG 2000 E
RECG 2500 E
12
Airflow
m3/h
1800
2700
3600
4500
1840
2760
3680
4600
2400
3200
4800
5600
2700
3600
5400
6300
Power
Fans
230Vx1
kW
0,212
0,318
0,424
0,530
0,132
0,198
0,264
0,330
0,642
0,856
1,284
1,498
0,225
0,300
0,450
0,525
Electrical Heating
Capacity
400Vx3-50Hz
kW
3/6/9
4/8/12
6/12/18
6/12/18
3/6/9
4/8/12
6/12/18
6/12/18
5/10/15
7,5/15/22,5
10/20/30
10/20/30
5/10/15
7,5/15/22,5
10/20/30
10/20/30
Current
Fans
230Vx1
A
0,94
1,41
1,88
2,35
1,14
1,71
2,28
2,85
2,85
3,80
5,70
6,65
1,95
2,60
3,90
4,55
Power
Fans
230Vx1
kW
0,212
0,318
0,424
0,530
0,132
0,198
0,264
0,330
0,642
0,856
1,284
1,498
0,225
0,300
0,450
0,525
Noise Level
(5 m)
dB(A)
55
56
57
58
56
57
58
59
57
58
59
60
61
62
63
64
Current
Fans
230Vx1
A
0,94
1,41
1,88
2,35
1,14
1,71
2,28
2,85
2,85
3,80
5,70
6,65
1,95
2,60
3,90
4,55
Noise Level
(5 m)
dB(A)
55
56
57
58
56
57
58
59
57
58
59
60
61
62
63
64
Weight
kg
57
85
109
137
57
85
109
137
61
90
118
145
61
90
118
145
Weight
kg
65
98
130
162
65
98
130
162
70
104
140
172
70
104
140
172
Recommended
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
Recommended
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
Price
euros
1.998
2.394
2.817
3.288
2.205
2.721
3.183
3.750
2.235
2.643
3.288
3.753
2.575
3.103
4.008
4.584
Price
euros
2.820
3.318
3.852
4.617
3.027
3.645
4.215
5.091
3.084
3.627
4.596
5.460
3.378
4.050
5.211
6.180
RECESSED WINDBOX |
WATER HEATED
Model
RM 1000 P
RM 1500 P
RM 2000 P
RM 2500 P
RECM 1000 P
RECM 1500 P
RECM 2000 P
RECM 2500 P
RG 1000 P
RG 1500 P
RG 2000 P
RG 2500 P
RECG 1000 P
RECG 1500 P
RECG 2000 P
RECG 2500 P
Airflow
m3/h
1660
2490
3320
4150
1720
2580
3440
4300
2250
3000
4500
5250
2550
3400
5100
5950
P86
Heating
Capacity
80/60ºC
kW
9,17
14,26
20,65
26,92
9,38
14,58
21,12
27,53
11,04
16,02
24,92
31,16
11,89
17,29
26,86
33,63
High Pressure Recessed Air Curtains
For Commercial And Industrial Doors
P64
Heating
Capacity
60/40ºC
kW
8,56
13,69
18,26
22,12
8,77
14,02
18,70
23,33
10,42
15,47
22,29
26,61
11,27
16,77
24,14
28,84
P54
Heating
Capacity
50/40ºC
kW
8,52
14,34
18,65
24,32
8,74
14,71
19,13
24,95
10,56
16,37
23,15
28,76
11,50
17,86
25,24
31,38
Power
Fans
230Vx1
kW
0,428
0,642
0,856
1,070
0,132
0,198
0,264
0,330
0,642
0,856
1,284
1,498
0,225
0,300
0,450
0,525
Current
Fans
230Vx1
A
1,90
2,85
3,80
4,75
1,14
1,71
2,28
2,85
2,85
3,80
5,70
6,65
1,95
2,60
3,90
4,55
Noise
Level
(5 m)
dB(A)
56
57
58
59
56
57
58
59
57
58
59
60
61
62
63
64
Weight
kg
63
93
122
153
63
93
122
153
67
98
131
163
67
98
131
163
Recom.
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
P86
Price
euros
2.283
2.757
3.219
3.915
2.478
3.051
3.579
4.389
2.517
2.982
3.690
4.383
2.845
3.424
4.380
5.037
P64
Price
euros
2.361
2.850
3.366
4.119
2.562
3.144
3.735
4.605
2.598
3.069
3.834
4.584
2.922
3.501
4.516
5.367
P54
Price
euros
2.496
3.009
3.555
4.416
2.697
3.303
3.924
4.902
2.733
3.228
4.023
4.881
3.057
3.660
4.705
5.664
SLB
SPANG-SIL
Water heated: connection pipes P86 and P64 are 2x3/4” female (male if lateral pipes), P54 2x1” male. P86 2 rows coil, P64 3 rows coil, P54 4 rows coil.
Special Finishes
Inlet and outlet grille painting
according RAL chart or metallic
Accessories
IR CONTROL CLEVER
CH-5HW-NE
TD-NE
IN-NE-II
DC
V-S/M
V-T
AFS-INS
SPWR
SPCT
13
SMART |
Decorative High Pressure Air Curtains
For Commercial And Industrial Doors
• Stylish, discreet and contemporary design adaptive to any interior architecture.
• Smooth front panel can be customized with logotypes, lighting, lettering or safety
and informative signals, according to the client requirements.
• Self-supporting steel rounded casing with edgeless plastic side covers, finished
in structural epoxy-polyester painting white colour RAL9016 as standard. Other
colours are available on request.
• Hidden top air entrance, avoiding the inside view of the unit and the inlet grille.
• Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side.
• Double-inlet centrifugal fans driven by an external rotor motor and low noise level.
5-speed selector. “EC” models assembled with very low consumption efficiency
fans.
• Includes Plug&Play control with 7m RJ45 cable and infrared remote control.
Optional: Clever control (programmable, automatic, intelligent, energy saving,
Modbus RTU for BMS…).
AIR ONLY
Model
SMART M 1000 A
SMART M 1500 A
SMART M 2000 A
SMART M 2500 A
SMART M 3000 A
SMART ECM 1000 A
SMART ECM 1500 A
SMART ECM 2000 A
SMART ECM 2500 A
SMART ECM 3000 A
SMART G 1000 A
SMART G 1500 A
SMART G 2000 A
SMART G 2500 A
SMART G 3000 A
SMART ECG 1000 A
SMART ECG 1500 A
SMART ECG 2000 A
SMART ECG 2500 A
SMART ECG 3000 A
Airflow
m3/h
1800
2700
3600
4500
5400
1840
2760
3680
4600
5520
2400
3200
4800
5600
6400
2700
3600
5400
6300
7200
ELECTRICAL HEATED
Model
SMART M 1000 E
SMART M 1500 E
SMART M 2000 E
SMART M 2500 E
SMART M 3000 E
SMART ECM 1000 E
SMART ECM 1500 E
SMART ECM 2000 E
SMART ECM 2500 E
SMART ECM 3000 E
SMART G 1000 E
SMART G 1500 E
SMART G 2000 E
SMART G 2500 E
SMART G 3000 E
SMART ECG 1000 E
SMART ECG 1500 E
SMART ECG 2000 E
SMART ECG 2500 E
SMART ECG 3000 E
14
Airflow
m3/h
1800
2700
3600
4500
5400
1840
2760
3680
4600
5520
2400
3200
4800
5600
6400
2700
3600
5400
6300
7200
Power
Fans
230Vx1
kW
0,212
0,318
0,424
0,530
0,636
0,132
0,198
0,264
0,330
0,396
0,642
0,856
1,284
1,498
1,712
0,225
0,300
0,450
0,525
0,600
Electrical Heating
Capacity
400Vx3-50Hz
kW
3/6/9
4/8/12
6/12/18
6/12/18
8/16/24
3/6/9
4/8/12
6/12/18
6/12/18
8/16/24
5/10/15
7,5/15/22,5
10/20/30
10/20/30
10/20/30
5/10/15
7,5/15/22,5
10/20/30
10/20/30
10/20/30
Current
Fans
230Vx1
A
0,94
1,41
1,88
2,35
2,82
1,14
1,71
2,28
2,85
3,42
2,85
3,80
5,70
6,65
7,60
1,95
2,60
3,90
4,55
5,20
Power
Fans
230Vx1
kW
0,212
0,318
0,424
0,530
0,636
0,132
0,198
0,264
0,330
0,396
0,642
0,856
1,284
1,498
1,712
0,225
0,300
0,450
0,525
0,600
Noise Level
(5 m)
dB(A)
53
54
55
56
57
54
55
56
57
58
55
56
57
58
59
59
60
61
62
63
Current
Fans
230Vx1
A
0,94
1,41
1,88
2,35
2,82
1,14
1,71
2,28
2,85
3,42
2,85
3,80
5,70
6,65
7,60
1,95
2,60
3,90
4,55
5,20
Noise Level
(5 m)
dB(A)
53
54
55
56
57
54
55
56
57
58
55
56
57
58
59
59
60
61
62
63
Weight
kg
34
50
62
66
76
34
50
62
66
76
38
55
72
76
86
38
55
72
76
86
Weight
kg
41
62
80
86
99
41
62
80
86
99
46
68
90
96
109
46
68
90
96
109
Recommended
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
4,2
Recommended
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
4,2
Price
euros
1.383
1.716
2.082
2.595
3.675
1.614
2.040
2.535
3.168
4.275
1.626
1.977
2.574
3.087
4.170
1.941
2.382
3.219
3.840
5.229
Price
euros
2.256
2.685
3.165
3.996
5.595
2.475
3.009
3.618
4.578
6.231
2.535
3.012
4.020
4.965
6.240
2.838
3.396
4.662
5.721
7.263
SMART |
Decorative High Pressure Air Curtains
For Commercial And Industrial Doors
WATER HEATED
Model
SMART M 1000 P
SMART M 1500 P
SMART M 2000 P
SMART M 2500 P
SMART M 3000 P
SMART ECM 1000 P
SMART ECM 1500 P
SMART ECM 2000 P
SMART ECM 2500 P
SMART ECM 3000 P
SMART G 1000 P
SMART G 1500 P
SMART G 2000 P
SMART G 2500 P
SMART G 3000 P
SMART ECG 1000 P
SMART ECG 1500 P
SMART ECG 2000 P
SMART ECG 2500 P
SMART ECG 3000 P
Airflow
m3/h
1660
2490
3320
4150
4980
1720
2580
3440
4300
5160
2250
3000
4500
5250
6000
2550
3400
5100
5950
6800
P86
Heating
Capacity
80/60ºC
kW
9,17
14,26
20,65
26,92
33,24
9,38
14,58
21,12
27,53
40,00
11,04
16,02
24,92
31,16
37,35
11,89
17,29
26,86
33,63
40,34
P64
Heating
Capacity
60/40ºC
kW
8,56
13,69
18,26
22,12
28,37
8,77
14,02
18,70
23,33
29,05
10,42
15,47
22,29
26,61
32,10
11,27
16,77
24,14
28,84
34,81
P54
Heating
Capacity
50/40ºC
kW
8,52
14,34
18,65
24,32
29,77
8,74
14,71
19,13
24,95
30,54
10,56
16,37
23,15
28,76
34,03
11,50
17,86
25,24
31,38
37,16
Power
Fans
230Vx1
kW
0,428
0,642
0,856
1,070
1,280
0,132
0,198
0,264
0,330
0,396
0,642
0,856
1,284
1,498
1,712
0,225
0,300
0,450
0,525
0,600
Current
Fans
230Vx1
A
1,90
2,85
3,80
4,75
5,70
1,14
1,71
2,28
2,85
3,42
2,85
3,80
5,70
6,65
7,60
1,95
2,60
3,90
4,55
5,20
Noise
Level
(5 m)
dB(A)
54
55
56
57
58
54
55
56
57
58
55
56
57
58
59
59
60
61
62
63
Weight
kg
39
58
73
79
91
39
58
73
79
91
44
64
83
87
99
44
64
83
87
99
Recom.
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
4,2
P86
Price
euros
1.683
2.076
2.529
3.282
4.527
1.899
2.388
2.952
3.840
5.148
1.923
2.334
2.997
3.750
5.019
2.217
2.709
3.612
4.479
6.045
P64
Price
euros
1.770
2.175
2.694
3.513
4.845
1.986
2.484
3.114
4.068
5.433
2.007
2.427
3.150
3.963
5.313
2.307
2.805
3.759
4.707
6.351
P54
Price
euros
1.905
2.334
2.883
3.810
5.214
2.121
2.643
3.303
4.365
5.802
2.142
2.586
3.339
4.260
5.682
2.442
2.964
3.948
5.004
6.720
Water heated: connection pipes P86 and P64 are 2x3/4” female, P54 2x1” male. P86 2 rows coil, P64 3 rows coil, P54 4 rows coil.
Smooth or customizable
front panel with logos,
lighting or signage
Hidden top
air entrance
Special Finishes
Stainless steel casing AISI 304
Painting according RAL chart
or metallic
Accessories
IR CONTROL CLEVER
CH-5HW-NE
TD-NE
IN-NE-II
DC
V-S/M
V-T
AFS-INS
SPWR
SLB/SPCT
15
ZEN |
Decorative Air Curtains
For Commercial Doors
• Decorative air curtain in contemporary architectural style. Its minimalist and smart
design integrates in any environment and offers infinite options to customize.
• Can include personalized logotypes, signs or graphic designs. It can even
incorporate clocks or lighting.
• Front anodized aluminium panels. Optionally manufactured in brushed or mirror
polished stainless steel. Other materials are possible, such as wood, metal, etc.
• Central structure made of galvanized steel finished in black forge as standard.
Other colours are available on request.
• Anodized aluminium outlet vanes, airfoil shaped, adjustable in both directions.
• Double-inlet centrifugal fans driven by an external rotor motor and low noise level.
5-speed selector. “EC” models assembled with very low consumption efficiency
fans.
• “P” type with water heated coil. “E” type with electrical shielded elements, three
stages with integrated regulation. “A” type without heating, air only. Optional
expansion DX coil.
• Includes Plug&Play control with 7m RJ45 cable and infrared remote control.
Optional: Clever control (programmable, automatic, intelligent, energy saving,
Modbus RTU for BMS…).
AIR ONLY
Model
ZEN M 1000 A
ZEN M 1500 A
ZEN M 2000 A
ZEN M 2500 A
ZEN G 1000 A
ZEN G 1500 A
ZEN G 2000 A
ZEN G 2500 A
ZEN ECG 1000 A
ZEN ECG 1500 A
ZEN ECG 2000 A
ZEN ECG 2500 A
Airflow
m3/h
1980
2640
3960
4620
2400
3200
4800
5600
2700
3600
5400
6300
ELECTRICAL HEATED
Model
ZEN M 1000 E
ZEN M 1500 E
ZEN M 2000 E
ZEN M 2500 E
ZEN G 1000 E
ZEN G 1500 E
ZEN G 2000 E
ZEN G 2500 E
ZEN ECG 1000 E
ZEN ECG 1500 E
ZEN ECG 2000 E
ZEN ECG 2500 E
16
Airflow
m3/h
1980
2640
3960
4620
2400
3200
4800
5600
2700
3600
5400
6300
Power
Fans
230Vx1
kW
0,318
0,424
0,636
0,742
0,642
0,856
1,284
1,498
0,225
0,300
0,450
0,525
Electrical Heating
Capacity
400Vx3-50Hz
kW
3/6/9
4/8/12
6/12/18
6/12/18
5/10/15
7,5/15/22,5
10/20/30
10/20/30
5/10/15
7,5/15/22,5
10/20/30
10/20/30
Current
Fans
230Vx1
A
1,41
1,88
2,82
3,29
2,85
3,80
5,70
6,65
1,95
2,60
3,90
4,55
Power
Fans
230Vx1
kW
0,318
0,424
0,636
0,742
0,642
0,856
1,284
1,498
0,225
0,300
0,450
0,525
Noise Level
(5 m)
dB(A)
55
56
57
58
57
58
59
60
61
62
63
64
Current
Fans
230Vx1
A
1,41
1,88
2,82
3,29
2,85
3,80
5,70
6,65
1,95
2,60
3,90
4,55
Noise Level
(5 m)
dB(A)
55
56
57
58
57
58
59
60
61
62
63
64
Weight
kg
32
46
62
75
36
50
69
83
36
50
69
83
Weight
kg
40
58
77
94
43
62
85
103
43
62
85
103
Recommended
Height
Up to
m
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
Recommended
Height
Up to
m
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
Price
euros
2.025
2.436
3.273
3.666
2.055
2.478
3.297
3.728
2.361
2.889
3.936
4.461
Price
euros
2.865
3.378
4.326
5.025
3.001
3.577
4.719
5.660
3.234
3.876
5.352
6.282
ZEN |
Decorative Air Curtains
For Commercial Doors
WATER HEATED
Model
ZEN M 1000 P
ZEN M 1500 P
ZEN M 2000 P
ZEN M 2500 P
ZEN G 1000 P
ZEN G 1500 P
ZEN G 2000 P
ZEN G 2500 P
ZEN ECG 1000 P
ZEN ECG 1500 P
ZEN ECG 2000 P
ZEN ECG 2500 P
Airflow
m3/h
1860
2480
3720
4340
2250
3000
4500
5250
2550
3400
5100
5950
P86
Heating
Capacity
80/60ºC
kW
9,84
14,23
22,17
27,69
11,04
16,02
24,92
31,16
11,89
17,29
26,86
33,63
P64
Heating
Capacity
60/40ºC
kW
9,22
13,65
19,70
23,48
10,42
15,47
22,29
26,61
11,27
16,77
24,14
28,84
P54
Heating
Capacity
50/40ºC
kW
10,56
16,37
23,15
28,76
11,50
17,86
25,24
31,38
Power
Fans
230Vx1
kW
0,318
0,424
0,636
0,742
0,642
0,856
1,284
1,498
0,225
0,300
0,450
0,525
Current
Fans
230Vx1
A
1,41
1,88
2,82
3,29
2,85
3,80
5,70
6,65
1,95
2,60
3,90
4,55
Noise
Level
(5 m)
dB(A)
55
56
57
58
57
58
59
60
61
62
63
64
Weight
kg
37
53
71
86
40
57
78
95
40
57
78
95
Recom.
Height
Up to
m
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
P86
Price
euros
2.409
2.877
3.783
4.422
2.439
2.919
3.804
4.467
2.736
3.321
4.437
5.205
P64
Price
euros
2.616
3.120
4.137
4.944
2.646
3.162
4.158
4.989
2.943
3.564
4.791
5.727
P54
Price
euros
2.784
3.321
4.350
5.289
3.081
3.723
4.983
6.027
Water heated: connection pipes P86 and P64 are 2x3/4” female (male if lateral pipes), P54 2x1” male. P86 2 rows coil, P64 3 rows coil, P54 4 rows coil.
Customizing and finishes
Different materials, textures and colours
standard /
painted
floral
crocco /
leather
screen
vintage
wood
logos /
signage
Examples of customized front panels
Stainless steel AISI 304
brushed or polished
Painting according RAL chart
or metallic
Accessories
IR CONTROL CLEVER
CH-5HW-NE
TD-NE
IN-NE-II
DC
V-S/M
V-T
AFS-INS
SPWR
SPCT
SLB
17
RUND | Cylindrical Air Curtains
• Decorative rounded air curtain for vertical or horizontal installation.
• Faceted self-supporting casing construction made of galvanized plated steel, finished
in structural epoxy-polyester painting white RAL9016 or silver grey RAL9006 as
standard. Other colours or stainless steel are available on request.
• Large perforated inlet grille avoiding intensive maintenance.
• Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side.
• Double-inlet centrifugal fans driven by an external rotor motor and low noise level.
5-speed selector. “EC” models assembled with very low consumption efficiency fans.
• “P” type with water heated coil. “E” type with electrical shielded elements, three
stages with integrated regulation. “A” type without heating, air only.
Optional expansion DX coil.
• Includes Plug&Play control with 7m RJ45 cable and infrared remote control.
Optional: Clever control (programmable, automatic, intelligent, energy saving,
Modbus RTU for BMS…).
AIR ONLY
Model
RUND M 1000 A
RUND M 1500 A
RUND M 2000 A
RUND M 2500 A
RUND M 3000 A
RUND G 1000 A
RUND G 1500 A
RUND G 2000 A
RUND G 2500 A
RUND G 3000 A
RUND ECG 1000 A
RUND ECG 1500 A
RUND ECG 2000 A
RUND ECG 2500 A
RUND ECG 3000 A
Airflow
m3/h
1980
2640
3960
4620
5280
2400
3200
4800
5600
6400
2700
3600
5400
6300
7200
ELECTRICAL HEATED
Model
RUND M 1000 E
RUND M 1500 E
RUND M 2000 E
RUND M 2500 E
RUND M 3000 E
RUND G 1000 E
RUND G 1500 E
RUND G 2000 E
RUND G 2500 E
RUND G 3000 E
RUND ECG 1000 E
RUND ECG 1500 E
RUND ECG 2000 E
RUND ECG 2500 E
RUND ECG 3000 E
18
Airflow
m3/h
1980
2640
3960
4620
5280
2400
3200
4800
5600
6400
2700
3600
5400
6300
7200
Power
Fans
230Vx1
kW
0,318
0,424
0,636
0,742
0,848
0,642
0,856
1,284
1,498
1,712
0,225
0,300
0,450
0,525
0,600
Electrical Heating
Capacity
400Vx3-50Hz
kW
3/6/9
4/8/12
6/12/18
6/12/18
8/16/24
5/10/15
7,5/15/22,5
10/20/30
10/20/30
10/20/30
5/10/15
7,5/15/22,5
10/20/30
10/20/30
10/20/30
Current
Fans
230Vx1
A
1,41
1,88
2,82
3,29
3,76
2,85
3,80
5,70
6,65
7,60
1,95
2,60
3,90
4,55
5,20
Power
Fans
230V-50Hz
kW
0,318
0,424
0,636
0,742
0,848
0,642
0,856
1,284
1,498
1,712
0,225
0,300
0,450
0,525
0,600
Noise Level
(5 m)
dB(A)
55
56
57
58
59
57
58
59
60
61
61
62
63
64
65
Current
Fans
230V-50Hz
A
1,41
1,88
2,82
3,29
3,76
2,85
3,80
5,70
6,65
7,60
1,95
2,60
3,90
4,55
5,20
Noise Level
(5 m)
dB(A)
55
56
57
58
59
57
58
59
60
61
61
62
63
64
65
Weight
kg
42
63
79
88
99
46
68
89
98
108
46
68
89
98
108
Weight
kg
49
75
97
108
119
54
81
107
118
128
54
81
107
118
128
Recommended
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
4,2
Recommended
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
4,2
Price
euros
3.594
3.891
4.491
5.013
5.994
3.627
3.933
4.521
5.061
6.381
3.936
4.353
5.166
5.823
6.921
Price
euros
4.446
4.845
5.559
6.390
7.896
4.518
4.944
5.961
6.915
8.358
4.821
5.355
6.606
7.671
8.970
RUND | Cylindrical Air Curtains
WATER HEATED
Model
Airflow
m3/h
1860
2480
3720
4340
4960
2250
3000
4500
5250
6000
2550
3400
5100
5950
6800
RUND M 1000 P
RUND M 1500 P
RUND M 2000 P
RUND M 2500 P
RUND M 3000 P
RUND G 1000 P
RUND G 1500 P
RUND G 2000 P
RUND G 2500 P
RUND G 3000 P
RUND ECG 1000 P
RUND ECG 1500 P
RUND ECG 2000 P
RUND ECG 2500 P
RUND ECG 3000 P
P86
Heating
Capacity
80/60ºC
kW
9,84
14,23
22,17
27,69
33,15
11,04
16,02
24,92
31,16
37,35
11,89
17,29
26,86
33,63
40,34
P64
Heating
Capacity
60/40ºC
kW
9,22
13,65
19,70
23,48
28,29
10,42
15,47
22,29
26,61
32,10
11,27
16,77
24,14
28,84
34,81
P54
Heating
Capacity
50/40ºC
kW
10,56
16,37
23,15
28,76
34,03
11,50
17,86
25,24
31,38
37,16
Power
Fans
230Vx1
kW
0,318
0,424
0,636
0,742
0,848
0,642
0,856
1,284
1,498
1,712
0,225
0,300
0,450
0,525
0,600
Current
Fans
230Vx1
A
1,41
1,88
2,82
3,29
3,76
2,85
3,80
5,70
6,65
7,60
1,95
2,60
3,90
4,55
5,20
Noise
Level
(5 m)
dB(A)
55
56
57
58
59
57
58
59
60
61
61
62
63
64
65
Weight
kg
47
71
90
101
112
52
77
100
109
119
52
77
100
109
119
Recom.
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
4,2
P86
Price
euros
3.894
4.248
4.917
5.691
6.870
3.951
4.317
5.064
5.805
7.149
4.227
4.701
5.583
6.492
7.788
P64
Price
euros
4.104
4.494
5.277
6.222
7.551
4.155
4.551
5.406
6.306
7.695
4.437
4.947
5.943
7.023
8.469
P54
Price
euros
4.293
4.710
5.598
6.606
8.070
4.575
5.106
6.135
7.323
8.844
Water heated: connection pipes P86 and P64 are 2x3/4” male (female if rear pipes), P54 2x1” male. P86 2 rows coil, P64 3 rows coil, P54 4 rows coil.
Installation Options
Wall anchored with
lateral arms
Wall/ceiling anchored
with arms
Wall/ceiling anchored
with angle supports
Vertical installation with foot
Ceiling anchored
with threaded rods
Floor anchored (goalpost)
Special Finishes
Stainless steel AISI 304
Painting according RAL chart
or metallic
Accessories
IR CONTROL CLEVER
SPARM-180
CH-5HW-NE
SPARM-90
TD-NE
IN-NE-II
DC
V-S/M
V-T
AFS-INS
SPWR
SLB/SPCT SPF-RUND SPJ2-RUND
SPANG-RUND SPANG-INT-RUND
19
DECO | Decorative Air Curtains For Commercial Doors
• Structure made of aluminium profiles and galvanized plated steel panels, finished
in structural epoxy-polyester white RAL 9016 or silver grey RAL 9006 as standard.
Other colours are available on request.
• Micro-perforated inlet grille with filter functions and easy service. It does not need
prefilter.
• Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side.
• Double-inlet centrifugal fans driven by an external rotor motor and low noise level.
5-speed selector. “EC” models assembled with very low consumption efficiency
fans.
• “P” type with water heated coil. “E” type with electrical shielded elements, three
stages with integrated regulation. “A” type without heating, air only. Optional
expansion DX coil.
• Includes Plug&Play control with 7m RJ45 cable and infrared remote control.
Optional: Clever control (programmable, automatic, intelligent, energy saving,
Modbus RTU for BMS…).
AIR ONLY
Model
DM 1000 A
DM 1500 A
DM 2000 A
DM 2500 A
DECM 1000 A
DECM 1500 A
DECM 2000 A
DECM 2500 A
DG 1000 A
DG 1500 A
DG 2000 A
DG 2500 A
DECG 1000 A
DECG 1500 A
DECG 2000 A
DECG 2500 A
Airflow
m3/h
1800
2700
3600
4500
1840
2760
3680
4600
2400
3200
4800
5600
2700
3600
5400
6300
Power
Fans
230V-50Hz
kW
0,212
0,318
0,424
0,530
0,132
0,198
0,264
0,330
0,642
0,856
1,284
1,498
0,225
0,300
0,450
0,525
Airflow
m3/h
1800
2700
3600
4500
1840
2760
3680
4600
2400
3200
4800
5600
2700
3600
5400
6300
Electrical Heating
Capacity
400Vx3-50Hz
kW
3/6/9
4/8/12
6/12/18
6/12/18
3/6/9
4/8/12
6/12/18
6/12/18
5/10/15
7,5/15/22,5
10/20/30
10/20/30
5/10/15
7,5/15/22,5
10/20/30
10/20/30
ELECTRICAL HEATED
Model
DM 1000 E
DM 1500 E
DM 2000 E
DM 2500 E
DECM 1000 E
DECM 1500 E
DECM 2000 E
DECM 2500 E
DG 1000 E
DG 1500 E
DG 2000 E
DG 2500 E
DECG 1000 E
DECG 1500 E
DECG 2000 E
DECG 2500 E
20
Current
Fans
230V-50Hz
A
0,94
1,41
1,88
2,35
1,14
1,71
2,28
2,85
2,85
3,80
5,70
6,65
1,95
2,60
3,90
4,55
Power
Fans
230V-50Hz
kW
0,212
0,318
0,424
0,530
0,132
0,198
0,264
0,330
0,642
0,856
1,284
1,498
0,225
0,300
0,450
0,525
Noise Level
(5 m)
dB(A)
55
56
57
58
56
57
58
59
57
58
59
60
61
62
63
64
Current
Fans
230V-50Hz
A
0,94
1,41
1,88
2,35
1,14
1,71
2,28
2,85
2,85
3,80
5,70
6,65
1,95
2,60
3,90
4,55
Noise Level
(5 m)
dB(A)
55
56
57
58
56
57
58
59
57
58
59
60
61
62
63
64
Weight
kg
51
75
96
108
51
75
96
108
55
80
106
118
55
80
106
118
Weight
kg
58
87
114
128
58
87
114
128
63
93
124
138
63
93
124
138
Recommended
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
Recommended
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
Price
euros
2.028
2.469
2.919
3.528
2.247
2.778
3.351
4.029
2.259
2.718
3.387
3.993
2.559
3.102
4.002
4.668
Price
euros
2.859
3.435
3.996
5.115
3.069
3.699
4.383
5.370
3.127
3.763
4.817
5.957
3.414
4.068
5.376
6.459
DECO | Decorative Air Curtains For Commercial Doors
WATER HEATED
Model
DM 1000 P
DM 1500 P
DM 2000 P
DM 2500 P
DECM 1000 P
DECM 1500 P
DECM 2000 P
DECM 2500 P
DG 1000 P
DG 1500 P
DG 2000 P
DG 2500 P
DECG 1000 P
DECG 1500 P
DECG 2000 P
DECG 2500 P
Airflow
m3/h
1660
2490
3320
4150
1720
2580
3440
4300
2250
3000
4500
5250
2550
3400
5100
5950
P86
Heating
Capacity
80/60ºC
kW
9,17
14,26
20,65
26,92
9,38
14,58
21,12
27,53
11,04
16,02
24,92
31,16
11,89
17,29
26,86
33,63
P64
Heating
Capacity
60/40ºC
kW
8,56
13,69
18,26
22,12
8,77
14,02
18,70
23,33
10,42
15,47
22,29
26,61
11,27
16,77
24,14
28,84
P54
Heating
Capacity
50/40ºC
kW
8,52
14,34
18,65
24,32
8,74
14,71
19,13
24,95
10,56
16,37
23,15
28,76
11,50
17,86
25,24
31,38
Power
Fans
230Vx1
kW
0,428
0,642
0,856
1,070
0,132
0,198
0,264
0,330
0,642
0,856
1,284
1,498
0,225
0,300
0,450
0,525
Current
Fans
230Vx1
A
1,90
2,85
3,80
4,75
1,14
1,71
2,28
2,85
2,85
3,80
5,70
6,65
1,95
2,60
3,90
4,55
Noise
Level
(5 m)
dB(A)
56
57
58
59
56
57
58
59
57
58
59
60
61
62
63
64
Weight
kg
56
83
107
121
56
83
107
121
61
89
117
129
61
89
117
129
Recom.
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
P86
Price
euros
2.322
2.859
3.345
4.248
2.520
3.108
3.747
4.668
2.559
3.057
3.798
4.713
2.823
3.414
4.377
5.277
P64
Price
euros
2.400
2.946
3.501
4.449
2.601
3.201
3.903
4.884
2.637
3.192
3.948
4.914
2.907
3.504
4.515
5.493
SPCT
SLB
P54
Price
euros
2.535
3.105
3.690
4.746
2.736
3.360
4.092
5.181
2.772
3.351
4.137
5.211
3.042
3.663
4.704
5.790
Water heated: connection pipes P86 and P64 are 2x3/4” female, P54 2x1” male. P86 2 rows coil, P64 3 rows coil, P54 4 rows coil.
Installation Options
Joining 2 units
Adjustable fixing points through guide rails
Special Finishes
Painting according RAL chart
or metallic
Accessories
IR CONTROL CLEVER
CH-5HW-NE
TD-NE
IN-NE-II
DC
V-S/M
V-T
AFS-INS
SPWR
21
DAM |
High Pressure Air Curtains
For Commercial And Industrial Doors
• Self-supporting casing construction made of galvanized steel plate, finished in
structural epoxy-polyester painting white colour RAL9016 as standard. Other
colours or stainless steel are available on request.
• Front panel with option to customize and the possibility of including personalized
logos, signs, graphic designs, images, etc.
• The inlet areas are located behind the front panel. They do not need maintenance.
• Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side.
• Double-inlet centrifugal fans driven by an external rotor motor and low noise level.
5-speed selector. “EC” models assembled with very low consumption efficiency fans.
• “P” type with water heated coil. “E” type with electrical shielded elements, three
stages with integrated regulation. “A” type without heating, air only. Optional
expansion DX coil.
• Includes Plug&Play control with 7m RJ45 cable and infrared remote control.
Optional: Clever control (programmable, automatic, intelligent, energy saving,
Modbus RTU for BMS…).
AIR ONLY
Model
DAM M 1000 A
DAM M 1500 A
DAM M 2000 A
DAM M 2500 A
DAM M 3000 A
DAM ECM 1000 A
DAM ECM 1500 A
DAM ECM 2000 A
DAM ECM 2500 A
DAM ECM 3000 A
DAM G 1000 A
DAM G 1500 A
DAM G 2000 A
DAM G 2500 A
DAM G 3000 A
DAM ECG 1000 A
DAM ECG 1500 A
DAM ECG 2000 A
DAM ECG 2500 A
DAM ECG 3000 A
Airflow
m3/h
1800
2700
3600
4500
5400
1840
2760
3680
4600
5520
2400
3200
4800
5600
6400
2700
3600
5400
6300
7200
Power
Fans
230V-50Hz
kW
0,212
0,318
0,424
0,530
0,636
0,132
0,198
0,264
0,330
0,396
0,642
0,856
1,284
1,498
1,712
0,225
0,300
0,450
0,525
0,600
Airflow
m3/h
1800
2700
3600
4500
5400
1840
2760
3680
4600
5520
2400
3200
4800
5600
6400
2700
3600
5400
6300
7200
Electrical Heating
Capacity
400Vx3-50Hz
kW
3/6/9
4/8/12
6/12/18
6/12/18
8/16/24
3/6/9
4/8/12
6/12/18
6/12/18
8/16/24
5/10/15
7,5/15/22,5
10/20/30
10/20/30
10/20/30
5/10/15
7,5/15/22,5
10/20/30
10/20/30
10/20/30
ELECTRICAL HEATED
Model
DAM M 1000 E
DAM M 1500 E
DAM M 2000 E
DAM M 2500 E
DAM M 3000 E
DAM ECM 1000 E
DAM ECM 1500 E
DAM ECM 2000 E
DAM ECM 2500 E
DAM ECM 3000 E
DAM G 1000 E
DAM G 1500 E
DAM G 2000 E
DAM G 2500 E
DAM G 3000 E
DAM ECG 1000 E
DAM ECG 1500 E
DAM ECG 2000 E
DAM ECG 2500 E
DAM ECG 3000 E
22
Current
Fans
230V-50Hz
A
0,94
1,41
1,88
2,35
2,82
1,14
1,71
2,28
2,85
3,42
2,85
3,80
5,70
6,65
7,60
1,95
2,60
3,90
4,55
5,20
Power
Fans
230V-50Hz
kW
0,212
0,318
0,424
0,530
0,636
0,132
0,198
0,264
0,330
0,396
0,642
0,856
1,284
1,498
1,712
0,225
0,300
0,450
0,525
0,600
Noise Level
(5 m)
dB(A)
53
54
55
56
57
54
55
56
57
58
55
56
57
58
59
59
60
61
62
63
Current
Fans
230V-50Hz
A
0,94
1,41
1,88
2,35
2,82
1,14
1,71
2,28
2,85
3,42
2,85
3,80
5,70
6,65
7,60
1,95
2,60
3,90
4,55
5,20
Noise Level
(5 m)
dB(A)
55
56
57
58
59
56
57
58
59
60
57
58
59
60
61
61
62
63
64
65
Weight
kg
38
56
70
76
88
38
56
70
76
88
42
61
80
86
98
42
61
80
86
98
Weight
kg
45
68
88
96
111
45
68
88
96
111
50
74
98
106
121
50
74
98
106
121
Recommended
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
4,2
Recommended
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
4,2
Price
euros
1.455
1.872
2.310
2.745
3.801
1.674
2.205
2.760
3.243
4.476
1.686
2.157
2.751
3.213
4.272
1.980
2.556
3.372
3.852
5.079
Price
euros
2.286
2.799
3.348
4.071
5.667
2.496
3.126
3.795
4.584
6.339
2.553
3.141
4.173
4.953
6.258
2.841
3.531
4.788
5.676
7.098
DAM |
High Pressure Air Curtains
For Commercial And Industrial Doors
WATER HEATED
Model
DAM M 1000 P
DAM M 1500 P
DAM M 2000 P
DAM M 2500 P
DAM M 3000 P
DAM ECM 1000 P
DAM ECM 1500 P
DAM ECM 2000 P
DAM ECM 2500 P
DAM ECM 3000 P
DAM G 1000 P
DAM G 1500 P
DAM G 2000 P
DAM G 2500 P
DAM G 3000 P
DAM ECG 1000 P
DAM ECG 1500 P
DAM ECG 2000 P
DAM ECG 2500 P
DAM ECG 3000 P
Airflow
m3/h
1660
2490
3320
4150
4980
1720
2580
3440
4300
5160
2250
3000
4500
5250
6000
2550
3400
5100
5950
6800
P86
Heating
Capacity
80/60ºC
kW
9,17
14,26
20,65
26,92
33,24
9,38
14,58
21,12
27,53
40,00
11,04
16,02
24,92
31,16
37,35
11,89
17,29
26,86
33,63
40,34
P64
Heating
Capacity
60/40ºC
kW
8,56
13,69
18,26
22,12
28,37
8,77
14,02
18,70
23,33
29,05
10,42
15,47
22,29
26,61
32,10
11,27
16,77
24,14
28,84
34,81
P54
Heating
Capacity
50/40ºC
kW
8,52
14,34
18,65
24,32
29,77
8,74
14,71
19,13
24,95
30,54
10,56
16,37
23,15
28,76
34,03
11,50
17,86
25,24
31,38
37,16
Power
Fans
230Vx1
kW
0,428
0,642
0,856
1,070
1,280
0,132
0,198
0,264
0,330
0,396
0,642
0,856
1,284
1,498
1,712
0,225
0,300
0,450
0,525
0,600
Current
Fans
230Vx1
A
1,90
2,85
3,80
4,75
5,70
1,14
1,71
2,28
2,85
3,42
2,85
3,80
5,70
6,65
7,60
1,95
2,60
3,90
4,55
5,20
Noise
Level
(5 m)
dB(A)
56
57
58
59
60
56
57
58
59
60
57
58
59
60
61
61
62
63
64
65
Weight
kg
43
64
81
89
103
43
64
81
89
103
48
70
91
97
111
48
70
91
97
111
Recom.
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
4,2
P86
Price
euros
1.740
2.238
2.757
3.372
4.656
1.947
2.535
3.159
3.882
5.307
1.968
2.496
3.156
3.840
5.079
2.250
2.886
3.768
4.491
5.910
P64
Price
euros
1.824
2.331
2.913
3.576
4.932
2.031
2.628
3.315
4.098
5.580
2.049
2.589
3.312
4.044
5.343
2.334
2.979
3.924
4.707
6.183
P54
Price
euros
1.959
2.490
3.102
3.873
5.301
2.166
2.787
3.504
4.395
5.949
2.184
2.748
3.501
4.341
5.712
2.469
3.138
4.113
5.004
6.552
Water heated: connection pipes P86 and P64 are 2x3/4” female (male if lateral pipes), P54 2x1” male. P86 2 rows coil, P64 3 rows coil, P54 4 rows coil.
Customizing
Smooth or customizable
front panel with logos,
lighting or signage
Special Finishes
Stainless steel casing AISI 304
Painting according RAL chart
or metallic
Accessories
IR CONTROL CLEVER
CH-5HW-NE
TD-NE
IN-NE-II
DC
V-S/M
V-T
AFS-INS
SPWR
SLB/SPCT
SPF-MG
SPJ2-MG
23
RECESSED DAM |
Compact Recessed High Pressure Air Curtains
For Commercial And Industrial Doors
• Compact and low profile recessed air curtain with full grille view.
• Self-supporting casing construction made of galvanized steel plate, ready to be
installed recessed in a false ceiling.
• Inlet grille (free of maintenance) made with aluminium profiles and blow-out
nozzle, integrated in a single white frame colour RAL 9016. Other colours are
available on request.
• Double-inlet centrifugal fans driven by an external rotor motor and low noise level.
5-speed selector. “EC” models assembled with very low consumption efficiency fans.
• “P” type with water heated coil. “E” type with electrical shielded elements, three
stages with integrated regulation. “A” type without heating, air only. Optional
expansion DX coil.
• Includes Plug&Play control with 7m RJ45 cable and infrared remote control.
Optional: Clever control (programmable, automatic, intelligent, energy saving,
Modbus RTU for BMS…).
AIR ONLY
Model
RDAM M 1000 A
RDAM M 1500 A
RDAM M 2000 A
RDAM M 2500 A
RDAM ECM 1000 A
RDAM ECM 1000 A
RDAM ECM 2000 A
RDAM ECM 2500 A
RDAM G 1000 A
RDAM G 1500 A
RDAM G 2000 A
RDAM G 2500 A
RDAM ECG 1000 A
RDAM ECG 1500 A
RDAM ECG 2000 A
RDAM ECG 2500 A
Airflow
m3/h
1800
2700
3600
4500
1840
2760
3680
4600
2400
3200
4800
5600
2700
3600
5400
6300
Power
Fans
230V-50Hz
kW
0,212
0,318
0,424
0,530
0,132
0,198
0,264
0,330
0,642
0,856
1,284
1,498
0,225
0,300
0,450
0,525
Airflow
m3/h
1800
2700
3600
4500
1840
2760
3680
4600
2400
3200
4800
5600
2700
3600
5400
6300
Electrical Heating
Capacity
400Vx3-50Hz
kW
3/6/9
4/8/12
6/12/18
6/12/18
3/6/9
4/8/12
6/12/18
6/12/18
5/10/15
7,5/15/22,5
10/20/30
10/20/30
5/10/15
7,5/15/22,5
10/20/30
10/20/30
ELECTRICAL HEATED
Model
RDAM M 1000 E
RDAM M 1500 E
RDAM M 2000 E
RDAM M 2500 E
RDAM ECM 1000 E
RDAM ECM 1500 E
RDAM ECM 2000 E
RDAM ECM 2500 E
RDAM G 1000 E
RDAM G 1500 E
RDAM G 2000 E
RDAM G 2500 E
RDAM ECG 1000 E
RDAM ECG 1500 E
RDAM ECG 2000 E
RDAM ECG 2500 E
24
Current
Fans
230V-50Hz
A
0,94
1,41
1,88
2,35
1,14
1,71
2,28
2,85
2,85
3,80
5,70
6,65
1,95
2,60
3,90
4,55
Power
Fans
230V-50Hz
kW
0,212
0,318
0,424
0,530
0,132
0,198
0,264
0,330
0,642
0,856
1,284
1,498
0,225
0,300
0,450
0,525
Noise Level
(5 m)
dB(A)
55
56
57
58
56
57
58
59
57
58
59
60
61
62
63
64
Current
Fans
230V-50Hz
A
0,94
1,41
1,88
2,35
1,14
1,71
2,28
2,85
2,85
3,80
5,70
6,65
1,95
2,60
3,90
4,55
Noise Level
(5 m)
dB(A)
55
56
57
58
56
57
58
59
57
58
59
60
61
62
63
64
Weight
kg
45
66
84
93
45
66
84
93
49
71
94
103
49
71
94
103
Weight
kg
52
78
102
113
52
78
102
113
57
84
112
123
57
84
112
123
Recommended
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
Recommended
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
Price
euros
1.956
2.478
3.006
3.444
2.175
2.811
3.459
4.002
2.187
2.724
3.447
3.885
2.481
3.120
4.068
4.611
Price
euros
2.832
3.453
4.092
4.836
3.042
3.780
4.536
5.385
3.099
3.750
4.917
5.757
3.387
4.140
5.532
6.477
RECESSED DAM |
WATER HEATED
Model
RDAM M 1000 P
RDAM M 1500 P
RDAM M 2000 P
RDAM M 2500 P
RDAM ECM 1000 P
RDAM ECM 1500 P
RDAM ECM 2000 P
RDAM ECM 2500 P
RDAM G 1000 P
RDAM G 1500 P
RDAM G 2000 P
RDAM G 2500 P
RDAM ECG 1000 P
RDAM ECG 1500 P
RDAM ECG 2000 P
RDAM ECG 2500 P
Airflow
m3/h
1660
2490
3320
4150
1720
2580
3440
4300
2250
3000
4500
5250
2550
3400
5100
5950
Compact Recessed High Pressure Air Curtains
For Commercial And Industrial Doors
P86
Heating
Capacity
80/60ºC
kW
9,17
14,26
20,65
26,92
9,38
14,58
21,12
27,53
11,04
16,02
24,92
31,16
11,89
17,29
26,86
33,63
P64
Heating
Capacity
60/40ºC
kW
8,56
13,69
18,26
22,12
8,77
14,02
18,70
23,33
10,42
15,47
22,29
26,61
11,27
16,77
24,14
28,84
P54
Heating
Capacity
50/40ºC
kW
8,52
14,34
18,65
24,32
8,74
14,71
19,13
24,95
10,56
16,37
23,15
28,76
11,50
17,86
25,24
31,38
Power
Fans
230Vx1
kW
0,428
0,642
0,856
1,070
0,132
0,198
0,264
0,330
0,642
0,856
1,284
1,498
0,225
0,300
0,450
0,525
Current
Fans
230Vx1
A
1,90
2,85
3,80
4,75
1,14
1,71
2,28
2,85
2,85
3,80
5,70
6,65
1,95
2,60
3,90
4,55
Noise
Level
(5 m)
dB(A)
56
57
58
59
56
57
58
59
57
58
59
60
61
62
63
64
Weight
kg
50
74
95
106
50
74
95
106
55
80
105
114
55
80
105
114
Recom.
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
P86
Price
euros
2.241
2.847
3.453
4.110
2.448
3.141
3.855
4.638
2.469
3.063
3.852
4.530
2.751
3.450
4.464
5.250
P64
Price
euros
2.325
2.940
3.612
4.326
2.532
3.234
4.011
4.857
2.550
3.156
4.011
4.749
2.835
3.543
4.623
5.466
P54
Price
euros
2.460
3.099
3.801
4.623
2.667
3.393
4.200
5.154
2.685
3.315
4.200
5.046
2.970
3.702
4.812
5.763
SLB
SPANG-SIL
Water heated: connection pipes P86 and P64 are 2x3/4” female (male if lateral pipes), P54 2x1” male. P86 2 rows coil, P64 3 rows coil, P54 4 rows coil.
Special Finishes
Inlet and outlet grille painting
according RAL chart or metallic
Accessories
IR CONTROL CLEVER
CH-5HW-NE
TD-NE
IN-NE-II
DC
V-S/M
V-T
AFS-INS
SPWR
SPCT
25
HEAT PUMP AIR CURTAINS |
Heating and Cooling
Low Consumption Air Curtains
Heat Pump Technology
Heat pump is a device that uses a small amount of energy to move
heat from one location to another. This system is extremely efficient
because it simply transfers heat, rather than burn fuel to create it.
It consists of a closed circuit through which a special fluid (refrigerant)
flows. This fluid takes on a liquid or gaseous state according to
temperature and pressure conditions.
The circuit is composed by: compressor, condenser, expansion valve
and evaporator.
Advantages and Benefits
The new Airtecnics Heat Pump Air curtains are absolutely efficient reducing the heating cost and CO2 emissions up to 70%.
• Very high energy efficiency ratings to save big amounts of money on your energy bill
• Short Payback Period thanks to very high level of energy saving
• Heating and cooling included in the same system (reverse cycle)
• Environmentally Friendly as uses such low amounts of energy
Available Airtecnics Heat Pump Air Curtains:
• Heating/Cooling: Windbox M-ECM-G-ECG, Dam, Recessed Windbox, Smart, Recessed Dam, Variwind VW and Windbox L-XL.
• Only Heating: Deco, Rund, Zen, Rotowind, Variwind VP and Invisair.
Heat Pump vs Electrical Air Curtain - Energy Saving Example
How much money can I save using a Heat Pump Air curtain?
Example:
Door dimension: 2 m width by 3 m height
Running time: 12 hours/day, 6 days/week,
26 weeks (~ 1/2 year)
Energy cost:
0,17 €/kW/h (EU-27 average cost)
Selected unit: G 2000, 27kW
COP:
3,31 (Coefficient of Performance)
Electrical Air Curtain
Total Heating Power
27
kW
Air Curtain Price
3.828
Energy Consumption
50.544
Heat Pump Air Curtain
Difference
27
kW
0 kW
€/unit
10.987
€/unit
+ 7.159 €
kW/h
15.270
kW/h
- 35.274 kW/h
Energy Cost
8.592
€
2.596
€
- 5.996 €
CO2 Emissions
20.218
kg
6.108
kg
- 14.110 kg
Result: The payback periode is 1,2 years. We recover the price increase of Heat Pump air curtain in nearly 14 months and then we start saving money.
From the beginning we save energy and reduce CO2 emissions to the enviroment.
€
€
10000
9000
8000
7000
6000
5000
4000
3000
2000
1000
0
100000
80000
Electrical
Heated
70000
60000
50000
40000
30000
Heat
Pump
0
100000
60000
CO2
Electrical
Heated
80000
Savings
40000
1 2
3 4 5
6 7
8 9 10
Years
10 Years Energy Cost
25000
Electrical
Heated
20000
10000
Savings
Heat
Pump
5000
1 2 3 4 5 6 7 8 9 10
Payback Periode
26
Heat
Pump
15000
Heat
Pump
20000
0
Savings
20000
10000
1 Year Energy Cost
€
Electrical
Heated
Years
0
1 2 3 4 5 6 7 8 9 10
10 Years CO2 Emisions
Years
WINDBOX M,ECM,G,ECG DX |
Heat Pump Energy Saving Air Curtains
For TOSHIBA Outdoor Units
• Energy saving heat pump air curtains: Up to 70% reduction in costs and CO2
emissions (heating mode).
• Self-supporting casing construction made of galvanized steel plate, finished in
structural epoxy-polyester painting white colour RAL9016 as standard. Other
colours or stainless steel are available on request.
• Micro-perforated inlet grille with filter functions and easy service. Internal prefilter
included.
• Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side.
• Double-inlet centrifugal fans driven by an external rotor motor and low noise level.
5-speed selector. “EC” models assembled with very low consumption efficiency
fans.
• Includes direct expansion coil with sensors. Optional condensate water pump.
• Plug&Play control panel, infrared remote IR and 7m telephone cable included.
• TOSHIBA DX Interface KIT and programmable control included.
• Ready to connect to TOSHIBA Digital Inverter outdoor heat pump unit (R410A) with
expansion valve.
Model (*)
Airflow
Outdoor unit
Power Supply
M 1500 DX11-TO
M 2000 DX16-TO
M 2500 DX22-TO
M 3000 DX27-TO
ECM 1000 DX8-TO
ECM 1500 DX11-TO
ECM 2000 DX16-TO
ECM 2500 DX22-TO
ECM 3000 DX27-TO
G 1000 DX11-TO
G 1500 DX16-TO
G 2000 DX22-TO
G 2000 DX27-TO
G 2500 DX27-TO
G 3000 DX27-TO
G 3000 DX32/2-TO
ECG 1000 DX11-TO
ECG 1500 DX16-TO
ECG 2000 DX22-TO
ECG 2000 DX27-TO
ECG 2500 DX27-TO
ECG 3000 DX27-TO
ECG 3000 DX32/2-TO
m3/h
2160
2880
3600
4320
1640
2460
3280
4100
4920
2100
2800
4200
4200
4900
5600
5600
2190
2920
4380
4380
5110
5840
5840
230Vx1
RAV-SM1104ATP-E
RAV-SM1603AT-E
RAV-SM804ATP-E
RAV-SM1104ATP-E
RAV-SM1603AT-E
RAV-SM1104ATP-E
RAV-SM1603AT-E
2x RAV-SM1603AT-E
RAV-SM1104ATP-E
RAV-SM1603AT-E
2x RAV-SM1603AT-E
Outdoor unit
Power Supply
Power
Fans
230V-50Hz
Current
Fans
230V-50Hz
Noise Level
(5 m)
400Vx3 (**)
RAV-SP1104AT8-E
RAV-SP1604AT8-E
RAV-SM2244AT8-E
RAV-SM2804AT8-E
RAV-SP1104AT8-E
RAV-SP1604AT8-E
RAV-SM2244AT8-E
RAV-SM2804AT8-E
RAV-SP1104AT8-E
RAV-SP1604AT8-E
RAV-SM2244AT8-E
RAV-SM2804AT8-E
RAV-SM2804AT8-E
RAV-SM2804AT8-E
2x RAV-SP1604AT8-E
RAV-SP1104AT8-E
RAV-SP1604AT8-E
RAV-SM2244AT8-E
RAV-SM2804AT8-E
RAV-SM2804AT8-E
RAV-SM2804AT8-E
2x RAV-SP1604AT8-E
kW
0,642
0,856
1,070
1,280
0,132
0,198
0,264
0,330
0,396
0,642
0,856
1,284
1,284
1,498
1,712
1,712
0,225
0,300
0,450
0,450
0,525
0,600
0,600
A
2,85
3,80
4,75
5,70
1,14
1,71
2,28
2,85
3,42
2,85
3,80
5,70
5,70
6,65
7,60
7,60
1,95
2,60
3,90
3,90
4,55
5,20
5,20
dB(A)
57
58
59
60
56
57
58
59
60
57
58
59
59
60
61
61
61
62
63
63
64
65
65
Weight
Recom.
Height
Up to
Price
kg
53
69
86
103
35
53
69
86
103
50
59
92
92
96
99
109
50
59
92
92
96
109
109
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
4,2
4,2
4,2
euros
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
(*) DX is also applicable to the models: Recessed Windbox, Smart, Dam, Recessed Dam, Deco, Variwind, Rund, Zen, Rotowind, Invisair.
33/2 Coil with double circuit and two outdoor units of 16kW.
(**) Air curtains supply is always 230Vx1.
TOSHIBA
Digital Inverter
Outdoor Units
RAV-SM804ATP-E
RAV-SM1104ATP-E
RAV-SP1104AT8-E
RAV-SM1603AT-E
RAV-SP1604AT8-E
RAV-SM2244AT8-E
RAV-SM2804AT8-E
Heating
Capacity
Heating
Power
SCOP or
COP (*)
Cooling
Capacity
Cooling
Power
SEER or
EER (*)
Power
Supply
Pipes
Gas Liquid
Pipes
Minimum
Lenght
Pipes
Maximum
Lenght
Pipes
Maximum
Height
kW
8,0
11,2
11,2
16,0
16,0
22,4
27,0
kW
2,21
2,93
2,42
4,43
4,30
6,49
8,15
W/W
4,02
3,54
4,28
3,61
3,72
3,45
3,31
kW
6,7
10,0
10,0
14,0
14,0
20,0
23,0
kW
2,09
3,11
2,37
4,49
4,49
7,20
8,75
W/W
5,63
5,58
6,57
3,12
3,12
2,78
2,63
230Vx1
230Vx1
400Vx3
230Vx1
400Vx3
400Vx3
400Vx3
inch
5/8 3/8
5/8 3/8
5/8 3/8
5/8 3/8
5/8 3/8
1”1/8 1/2”
1”1/8 1/2”
m
5
5
3
5
3
7,5
7,5
m
30
50
75
50
75
70
70
m
30
30
30
30
30
30
30
(*) Energy efficiency: SCOP and SEER seasonal ratio under 12kW and COP and EER over 12kW.
27
WINDBOX M,ECM,G,ECG DX |
Heat Pump Energy Saving Air Curtains
For MITSUBISHI ELECTRIC Outdoor Units
• Energy saving heat pump air curtains: Up to 70% reduction in costs and CO2
emissions (heating mode).
• Self-supporting casing construction made of galvanized steel plate, finished in
structural epoxy-polyester painting white colour RAL9016 as standard. Other
colours or stainless steel are available on request.
• Micro-perforated inlet grille with filter functions and easy service. Internal prefilter
included.
• Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side.
• Double-inlet centrifugal fans driven by an external rotor motor and low noise level.
5-speed selector. “EC” models assembled with very low consumption efficiency
fans.
• Includes direct expansion coil with sensors. Optional condensate water pump.
• Plug&Play control panel, infrared remote IR and 7m telephone cable included.
• MITSUBISHI ELECTRIC DX Interface KIT and programmable control included.
• Ready to connect to MITSUBISHI ELECTRICAL Digital Inverter outdoor heat
pump unit (R410A) with expansion valve.
Model (*)
Airflow
Outdoor unit
Power Supply
M 1500 DX11-ME
M 2000 DX14-ME
M 2000 DX16-ME
M 2500 DX22-ME
M 3000 DX27-ME
ECM 1000 DX8-ME
ECM 1500 DX11-ME
ECM 1500 DX14-ME
ECM 2000 DX16-ME
ECM 2500 DX22-ME
ECM 3000 DX27-ME
G 1000 DX8-ME
G 1500 DX14-ME
G 2000 DX22-ME
G 2500 DX27-ME
G 3000 DX27-ME
G 3000 DX32/2-ME
ECG 1000 DX8-ME
ECG 1500 DX16-ME
ECG 2000 DX22-ME
ECG 2500 DX27-ME
ECG 3000 DX27-ME
ECG 3000 DX32/2-ME
m3/h
2160
2880
2880
3600
4320
1640
2460
2460
3280
4100
4920
2100
2800
4200
4900
5600
5600
2190
2920
4380
5110
5840
5840
230Vx1
PUHZ-ZRP100VKA
PUHZ-ZRP125VKA
PUHZ-ZRP140VKA
PUHZ-ZRP71VHA
PUHZ-ZRP100VKA
PUHZ-ZRP125VKA
PUHZ-ZRP140VKA
PUHZ-ZRP71VHA
PUHZ-ZRP125VKA
2x PUHZ-ZRP140VKA
PUHZ-ZRP71VHA
PUHZ-ZRP140VKA
2x PUHZ-ZRP140VKA
Outdoor unit
Power Supply
Power
Fans
230V-50Hz
Current
Fans
230V-50Hz
Noise Level
(5 m)
400Vx3 (**)
PUHZ-ZRP100YKA
PUHZ-ZRP125YKA
PUHZ-ZRP140YKA
PUHZ-ZRP200YKA
PUHZ-ZRP250YKA
PUHZ-ZRP100YKA
PUHZ-ZRP125YKA
PUHZ-ZRP140YKA
PUHZ-ZRP200YKA
PUHZ-ZRP250YKA
PUHZ-ZRP125YKA
PUHZ-ZRP200YKA
PUHZ-ZRP250YKA
PUHZ-ZRP250YKA
2x PUHZ-ZRP140YKA
PUHZ-ZRP140YKA
PUHZ-ZRP200YKA
PUHZ-ZRP250YKA
PUHZ-ZRP250YKA
2x PUHZ-ZRP140YKA
kW
0,642
0,856
0,856
1,070
1,280
0,132
0,198
0,198
0,264
0,330
0,396
0,642
0,856
1,284
1,498
1,712
1,712
0,225
0,300
0,450
0,525
0,600
0,600
A
2,85
3,80
3,80
4,75
5,70
1,14
1,71
1,71
2,28
2,85
3,42
2,85
3,80
5,70
6,65
7,60
7,60
1,95
2,60
3,90
4,55
5,20
5,20
dB(A)
57
58
58
59
60
56
57
57
58
59
60
57
58
59
60
61
61
61
62
63
64
65
65
Weight
Recom.
Height
Up to
Price
kg
53
69
69
86
103
35
53
53
69
86
103
50
59
92
96
109
109
50
59
92
96
109
109
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
4,2
4,2
euros
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
Pipes
Minimum
Lenght
Pipes
Maximum
Lenght
Pipes
Maximum
Height
m
-
m
50
75
75
75
75
75
75
100
100
m
30
30
30
30
30
30
30
30
30
(*) DX is also applicable to the models: Recessed Windbox, Smart, Dam, Recessed Dam, Deco, Variwind, Rund, Zen, Rotowind, Invisair.
33/2 Coil with double circuit and two outdoor units of 16kW.
(**) Air curtains supply is always 230Vx1.
MITSUBISHI
Digital Inverter
Outdoor Units
PUHZ-ZRP71VHA
PUHZ-ZRP100VKA
PUHZ-ZRP100YKA
PUHZ-ZRP125VKA
PUHZ-ZRP125YKA
PUHZ-ZRP140VKA
PUHZ-ZRP140YKA
PUHZ-ZRP200YKA
PUHZ-ZRP250YKA
Heating
Capacity
Heating
Power
SCOP or
COP (*)
Cooling
Capacity
Cooling
Power
SEER or
EER (*)
Power
Supply
Pipes
Gas Liquid
kW
8,0
11,2
11,2
14,0
14,0
16,0
16,0
22,4
27,0
kW
2,03
2,06
2,06
3,63
3,63
4,20
4,20
6,94
8,94
W/W
3,90
4,20
4,20
3,86
3,86
3,81
3,81
3,23
3,75
kW
7,1
10,0
10,0
12,5
12,5
13,4
13,4
19,0
22,0
kW
2,01
2,63
2,63
4,05
4,05
4,36
4,36
6,46
8,31
W/W
5,60
5,60
5,50
3,09
3,09
3,07
3,07
2,94
2,65
230Vx1
230Vx1
400Vx3
230Vx1
400Vx3
230Vx1
400Vx3
400Vx3
400Vx3
5/8
5/8
5/8
5/8
5/8
5/8
5/8
1
1
(*) Energy efficiency: SCOP and SEER seasonal ratio under 12kW and COP and EER over 12kW.
28
inch
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
1/2
WINDBOX M,ECM,G,ECG DX |
Heat Pump Energy Saving Air Curtains
For HITACHI Outdoor Units
• Energy saving heat pump air curtains: Up to 70% reduction in costs and CO2
emissions (heating mode).
• Self-supporting casing construction made of galvanized steel plate, finished in
structural epoxy-polyester painting white colour RAL9016 as standard. Other
colours or stainless steel are available on request.
• Micro-perforated inlet grille with filter functions and easy service. Internal prefilter
included.
• Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each
side.
• Double-inlet centrifugal fans driven by an external rotor motor and low noise level.
5-speed selector. “EC” models assembled with very low consumption efficiency fans.
• Includes direct expansion coil with sensors. Optional condensate water pump.
• Plug&Play control panel, infrared remote IR and 7m telephone cable included.
• HITACHI DX Interface KIT with expansion valve and programmable control included.
• Ready to connect to HITACHI Reversible DC Inverter outdoor heat pump unit
(R410A).
Model (*)
Airflow
m3/h
2160
3600
2460
4100
4920
2100
2800
4200
4900
4900
5600
2190
2190
2920
2920
4380
5110
5110
5840
M 1500 DX11-HI
M 2500 DX22-HI
ECM 1500 DX11-HI
ECM 2500 DX22-HI
ECM 3000 DX28-HI
G 1000 DX8-HI
G 1500 DX16-HI
G 2000 DX22-HI
G 2500 DX22-HI
G 2500 DX28-HI
G 3000 DX28-HI
ECG 1000 DX8-HI
ECG 1000 DX11-HI
ECG 1500 DX14-HI
ECG 1500 DX16-HI
ECG 2000 DX22-HI
ECG 2500 DX22-HI
ECG 2500 DX28-HI
ECG 3000 DX28-HI
Outdoor unit
Power Supply
230Vx1
RAS-4H(V)NCE
RAS-4H(V)NCE
RAS-3HVNC
RAS-6H(V)NCE
RAS-3HVNC
RAS-4H(V)NCE
RAS-5H(V)NCE
RAS-6H(V)NCE
-
Power
Fans
230V-50Hz
kW
0,642
1,070
0,198
0,330
0,396
0,642
0,856
1,284
1,498
1,498
1,712
0,225
0,225
0,300
0,300
0,450
0,525
0,525
0,600
Outdoor unit
Power Supply
400Vx3 (**)
RAS-4H(V)NCE
RAS-8HNCE
RAS-4H(V)NCE
RAS-8HNCE
RAS-10HNCE
RAS-6H(V)NCE
RAS-8HNCE
RAS-8HNCE
RAS-10HNCE
RAS-10HNCE
RAS-4H(V)NCE
RAS-5H(V)NCE
RAS-6H(V)NCE
RAS-8HNCE
RAS-8HNCE
RAS-10HNCE
RAS-10HNCE
Current
Fans
230V-50Hz
A
2,85
4,75
1,71
2,85
3,42
2,85
3,80
5,70
6,65
6,65
7,60
1,95
1,95
2,60
2,60
3,90
4,55
4,55
5,20
Noise Level
(5 m)
dB(A)
57
59
57
59
60
57
58
59
60
60
61
61
61
62
62
63
64
64
65
Weight
kg
53
86
53
86
103
50
59
92
96
96
109
50
50
59
59
92
96
96
109
Recom.
Height
Up to
m
3,5
3,5
3,8
3,8
3,8
3,8
3,8
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
4,2
4,2
4,2
4,2
Price
euros
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
consult
(*) DX is also applicable to the models: Recessed Windbox, Smart, Dam, Recessed Dam, Deco, Variwind, Rund, Zen, Rotowind, Invisair.
(**) Air curtains supply is always 230Vx1.
HITACHI
Reversible DC Inverter
Outdoor Units
RAS-3HVNC
RAS-4H(V)NCE
RAS-5H(V)NCE
RAS-6H(V)NCE
RAS-8HNCE
RAS-10HNCE
Heating
Capacity
Heating
Power
SCOP or
COP (*)
Cooling
Capacity
Cooling
Power
SEER or
EER (*)
Power
Supply
Pipes
Gas Liquid
kW
8,0
11,2
14,0
16,0
22,4
28,0
kW
1,90
2,54
3,39
4,23
5,28
7,12
W/W
4,21
4,41
4,12
3,78
4,24
3,93
kW
7,1
10,0
12,5
14,0
20,0
25,0
kW
1,94
2,44
3,53
4,25
5,95
7,81
W/W
3,66
4,10
3,54
3,29
3,36
3,20
230Vx1
230Vx1/400Vx3
230Vx1/400vX3
230Vx1/400vX3
400Vx3
400Vx3
5/8
5/8
5/8
5/8
1
1
inch
3/8
3/8
3/8
3/8
3/8
1/2
Pipes
Maximum
Lenght
Pipes
Maximum
Height
m
50
70
75
75
100
100
m
30
30
30
30
30
30
(*) Energy efficiency: SCOP and SEER seasonal ratio under 12kW and COP and EER over 12kW
Special Finishes
RAL chart
Stainless steel casing AISI 304
Accessories
IR CONTROL CLEVER
IN-NE-II
SPWR
SLB/SPCT
SPF-MG
SPJ2-MG
29
WINDBOX L,XL |
High Pressure Air Curtains
For Commercial And Industrial Doors
• Self-supporting casing construction made of galvanized steel plate, finished in
structural epoxy-polyester painting white colour RAL9016 as standard. Other
colours or stainless steel are available on request.
• Two frontal grille options. Industrial perforated by default.
• Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each
side.
• Double-inlet centrifugal fans driven by an external rotor motor and low noise level.
5-speed selector.
• “P” type with water heated coil. “E” type with electrical shielded elements, three
stages with integrated regulation. “A” type without heating, air only. Optional
expansion DX coil.
• Includes Plug&Play control with 10m RJ45 cable and infrared remote control.
Optional: Clever control (programmable, automatic, intelligent, energy saving,
Modbus RTU for BMS…).
AIR ONLY
Model
L 1000 A
L 1500 A
L 2000 A
L 2500 A
L 3000 A
XL 1000 A
XL 1500 A
XL 2000 A
XL 2500 A
XL 3000 A
Airflow
m3/h
4000
6000
8000
10000
12000
5300
7950
10600
13250
15900
Power
Fans
230V-50Hz
kW
1,04
1,56
2,08
2,60
3,12
1,40
2,10
2,80
3,50
4,20
Airflow
m3/h
4000
6000
8000
10000
12000
5300
7950
10600
13250
15900
Electrical Heating
Capacity
400Vx3-50Hz
kW
10/15/25
15/22,5/37,5
20/30/50
20/40/60
20/40/60
10/15/25
15/22,5/37,5
20/30/50
20/40/60
20/40/60
ELECTRICAL HEATED
Model
L 1000 E
L 1500 E
L 2000 E
L 2500 E
L 3000 E
XL 1000 E
XL 1500 E
XL 2000 E
XL 2500 E
XL 3000 E
30
Current
Fans
230V-50Hz
A
4,40
6,60
8,80
11,00
13,20
6,00
9,00
12,00
15,00
18,00
Power
Fans
230V-50Hz
kW
1,04
1,56
2,08
2,60
3,12
1,40
2,10
2,80
3,50
4,20
Noise Level
(5 m)
dB(A)
63
64
65
66
67
65
66
67
68
69
Current
Fans
230V-50Hz
A
4,40
6,60
8,80
11,00
13,20
6,00
9,00
12,00
15,00
18,00
Noise Level
(5 m)
dB(A)
63
64
65
66
67
65
66
67
68
69
Weight
kg
72
108
145
177
213
78
117
157
192
211
Weight
kg
90
135
180
225
270
95
144
192
240
288
Recommended
Height
Up to
m
5
5
5
5
5
7
7
7
7
7
Recommended
Height
Up to
m
5
5
5
5
5
7
7
7
7
7
Price
euros
3.273
4.116
5.259
6.333
7.557
3.543
4.521
5.799
7.008
8.367
Price
euros
5.019
6.618
8.310
10.050
11.805
5.289
7.023
8.850
10.725
12.615
WINDBOX L,XL |
WATER HEATED
Model
Airflow
m3/h
3800
5700
7600
9500
11400
4900
7350
9800
12250
14700
L 1000 P
L 1500 P
L 2000 P
L 2500 P
L 3000 P
XL 1000 P
XL 1500 P
XL 2000 P
XL 2500 P
XL 3000 P
High Pressure Air Curtains
For Commercial And Industrial Doors
P86
Heating
Capacity
80/60ºC
kW
19,68
29,64
43,01
56,01
69,27
22,68
34,52
50,10
65,29
80,79
P64
Heating
Capacity
60/40ºC
kW
16,18
25,92
35,58
45,55
56,78
18,98
30,45
41,83
53,56
66,78
P54
Heating
Capacity
50/40ºC
kW
17,18
29,04
38,93
49,36
59,96
20,43
34,55
46,36
58,81
71,47
Power
Fans
230Vx1
kW
1,04
1,56
2,08
2,60
3,12
1,40
2,10
2,80
3,50
4,20
Current
Fans
230Vx1
A
4,40
6,60
8,80
11,00
13,20
6,00
9,00
12,00
15,00
18,00
Noise
Level
(5 m)
dB(A)
62
63
64
65
66
64
65
66
67
68
Weight
kg
89
128
171
214
260
94
137
183
227
278
Recom.
Height
Up to
m
5
5
5
5
5
7
7
7
7
7
P86
Price
euros
3.858
4.830
6.138
7.593
9.120
4.128
5.235
6.678
8.268
9.930
P64
Price
euros
3.942
4.980
6.318
7.845
9.507
4.212
5.385
6.858
8.520
10.317
P54
Price
euros
4.077
5.139
6.507
8.142
9.876
4.347
5.544
7.047
8.817
10.686
Water heated: P86 2 rows coil, P64 3 rows coil, P54 4 rows coil.
2x1” for 1000 and 1500, 2x1¼” for 2000 and 2500, 2x1½” for 3000.
Connection pipes P86, P64 and P54 are female (male if lateral pipes).
Installation Options
Model
1000
1500
2000
2500
3000
Telescopic
outlet kit
euros
407
437
512
565
955
Telescopic
inlet kit
euros
408
442
516
571
965
Telescopic false
ceiling kit
euros
815
879
1.028
1.136
1.920
Telescopic false ceiling
kit + plenum
euros
1.267
1.378
1.598
1.774
3.000
Plenum
surface mounting
euros
452
499
570
638
1.080
Special Finishes
Painting according RAL chart
or metallic
Stainless steel casing AISI 304
Accessories
IR CONTROL CLEVER
CH-5HW-NE
TD-NE
IN-NE-II
DC
V-S/M
V-T
AFS-INS
SPWR
SLB/SPCT
SPF-LXL
SPJ2-LXL
31
INVISAIR | Recessed Air Curtains For Commercial and Industrial Doors
• Specially designed for applications where the body of the air curtain is to be
installed inside a column or bulkhead for architectural reasons. It can be vertically
or horizontally mounted.
• Self-supporting casing construction made of galvanized steel plate, finished in
structural epoxy-polyester painting white colour RAL9016 as standard. Other
colours or stainless steel are available on request.
• The air flow of Invisair follows a straight line from the air inlet grille to the to the
discharge. Inlet area inside a bulkhead or column should be designed with
suitable grille provided by others.
• Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side.
• Double-inlet centrifugal fans driven by an external rotor motor and low noise level.
5-speed selector. “EC” models assembled with very low consumption efficiency
fans.
• “P” type with water heated coil. “E” type with electrical shielded elements, three
stages with integrated regulation. “A” type without heating, air only. Optional
expansion DX coil.
• Includes Plug&Play control with 7m RJ45 cable and infrared remote control.
Optional: Clever control (programmable, automatic, intelligent, energy saving,
Modbus RTU for BMS…)
AIR ONLY
Model
IM 1500 A
IM 2000 A
IM 2500 A
IG 1500 A
IG 2000 A
IG 2500 A
IECG 1500 A
IECG 2000 A
IECG 2500 A
Airflow
m3/h
2640
3960
4620
3200
4800
5600
3600
5400
6300
Power
Fans
230V-50Hz
kW
0,424
0,636
0,742
0,856
1,284
1,498
0,300
0,450
0,525
Airflow
m3/h
2640
3960
4620
3200
4800
5600
3600
5400
6300
Electrical Heating
Capacity
400Vx3-50Hz
kW
4/8/12
6/12/18
6/12/18
7,5/15/22,5
10/20/30
10/20/30
7,5/15/22,5
10/20/30
10/20/30
ELECTRICAL HEATED
Model
IM 1500 E
IM 2000 E
IM 2500 E
IG 1500 E
IG 2000 E
IG 2500 E
IECG 1500 E
IECG 2000 E
IECG 2500 E
32
Current
Fans
230V-50Hz
A
1,88
2,82
3,29
3,80
5,70
6,65
2,60
3,90
4,55
Power
Fans
230V-50Hz
kW
0,424
0,636
0,742
0,856
1,284
1,498
0,300
0,450
0,525
Noise Level
(5 m)
dB(A)
56
57
58
58
59
60
62
63
64
Current
Fans
230V-50Hz
A
1,88
2,82
3,29
3,80
5,70
6,65
2,60
3,90
4,55
Noise Level
(5 m)
dB(A)
56
57
58
58
59
60
62
63
64
Weight
kg
55
68
73
60
78
83
60
78
83
Weight
kg
67
86
93
73
96
103
73
96
103
Recommended
Height
Up to
m
3,5
3,5
3,5
3,8
3,8
3,8
4,2
4,2
4,2
Recommended
Height
Up to
m
3,5
3,5
3,5
3,8
3,8
3,8
4,2
4,2
4,2
Price
euros
2.763
3.366
3.933
2.913
3.558
4.116
3.213
4.050
4.722
Price
euros
3.702
4.416
5.289
3.897
4.918
5.870
4.200
5.478
6.555
INVISAIR | Recessed Air Curtains For Commercial and Industrial Doors
WATER HEATED
Airflow
Model
IM 1500 P
IM 2000 P
IM 2500 P
IG 1500 P
IG 2000 P
IG 2500 P
IECG 1500 P
IECG 2000 P
IECG 2500 P
m3/h
2480
3720
4340
3000
4500
5250
3400
5100
5950
P86
Heating
Capacity
80/60ºC
kW
14,23
22,17
27,69
16,02
24,92
31,16
17,29
26,86
33,63
P64
Heating
Capacity
60/40ºC
kW
13,65
19,70
23,48
15,47
22,29
26,61
16,77
24,14
28,84
P54
Heating
Capacity
50/40ºC
kW
16,37
23,15
28,76
17,86
25,24
31,38
Power
Fans
230Vx1
kW
0,424
0,636
0,742
0,856
1,284
1,498
0,300
0,450
0,525
Current
Fans
230Vx1
A
1,88
2,82
3,29
3,80
5,70
6,65
2,60
3,90
4,55
Noise
Level
(5 m)
dB(A)
56
57
58
58
59
60
62
63
64
Weight
kg
63
78
86
69
89
94
69
89
94
Recom.
Height
Up to
m
3,5
3,5
3,5
3,8
3,8
3,8
4,2
4,2
4,2
P86
Price
euros
3.105
3.774
4.584
3.252
3.963
4.746
3.546
4.446
5.364
P64
Price
euros
3.198
3.933
4.803
3.339
4.110
4.950
3.639
4.608
5.583
P54
Price
euros
3.498
4.299
5.247
3.798
4.797
5.880
Water heated: connection pipes P86 and P64 are 2x3/4” female (male if lateral pipes), P54 2x1” male. P86 2 rows coil, P64 3 rows coil, P54 4 rows coil.
Installation Options
On top horizontal mounting
Vertical
left side
Installation
Vertical
right side
Installation
Special Finishes
Painting according RAL chart
or metallic
Accessories
IR CONTROL CLEVER
CH-5HW-NE
TD-NE
IN-NE-II
DC
V-S/M
V-T
AFS-INS
SPWR
SLB/SPCT
SPF-INV
SPJ2-INV
33
ROTOWIND | Air Curtains For Revolving Doors
• Specially designed to be installed in all type of revolving doors. Two possible
layouts, tailored dimensions.
• Self-supporting casing construction made of galvanized steel plate, finished in
structural epoxy-polyester painting white colour RAL9016 as standard. Other
colours or stainless steel are available on request.
• Large perforated inlet grille avoiding intensive maintenance.
• Circular anodized aluminium outlet vanes, airfoil shaped.
• Double-inlet centrifugal fans driven by an external rotor motor and low noise level.
5-speed selector. “EC” models assembled with very low consumption efficiency
fans.
• “P” type with water heated coil. “E” type with electrical shielded elements, three
stages with integrated regulation. “A” type without heating, air only. Optional
expansion DX coil.
• Includes Plug&Play control with 7m RJ45 cable and infrared remote control.
Optional: Clever control (programmable, automatic, intelligent, energy saving,
Modbus RTU for BMS…).
AIR ONLY
Model
ROTO M 1000 A
ROTO M 1500 A
ROTO M 2000 A
ROTO M 2500 A
ROTO G 1000 A
ROTO G 1500 A
ROTO G 2000 A
ROTO G 2500 A
ROTO ECG 1000 A
ROTO ECG 1500 A
ROTO ECG 2000 A
ROTO ECG 2500 A
Airflow
m3/h
1980
2640
3960
4620
2400
3200
4800
5600
2700
3600
5400
6300
Power
Fans
230V-50Hz
kW
0,318
0,424
0,636
0,742
0,642
0,856
1,284
1,498
0,225
0,300
0,450
0,525
Airflow
m3/h
1980
2640
3960
4620
2400
3200
4800
5600
2700
3600
5400
6300
Electrical Heating
Capacity
400Vx3-50Hz
kW
3/6/9
4/8/12
6/12/18
6/12/18
5/10/15
7,5/15/22,5
10/20/30
10/20/30
5/10/15
7,5/15/22,5
10/20/30
10/20/30
ELECTRICAL HEATED
Model
ROTO M 1000 E
ROTO M 1500 E
ROTO M 2000 E
ROTO M 2500 E
ROTO G 1000 E
ROTO G 1500 E
ROTO G 2000 E
ROTO G 2500 E
ROTO ECG 1000 E
ROTO ECG 1500 E
ROTO ECG 2000 E
ROTO ECG 2500 E
34
Current
Fans
230V-50Hz
A
1,41
1,88
2,82
3,29
2,85
3,80
5,70
6,65
1,95
2,60
3,90
4,55
Power
Fans
230V-50Hz
kW
0,318
0,424
0,636
0,742
0,642
0,856
1,284
1,498
0,225
0,300
0,450
0,525
Noise Level
(5 m)
dB(A)
55
56
57
58
57
58
59
60
61
62
63
64
Current
Fans
230V-50Hz
A
1,41
1,88
2,82
3,29
2,85
3,80
5,70
6,65
1,95
2,60
3,90
4,55
Noise Level
(5 m)
dB(A)
55
56
57
58
57
58
59
60
61
62
63
64
Weight
kg
-
Weight
kg
-
Recommended
Height
Up to
m
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
Recommended
Height
Up to
m
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
Price
euros
5.385
5.844
7.056
7.698
5.415
5.886
7.077
7.872
5.724
6.303
7.725
8.502
Price
euros
6.231
6.849
8.118
9.069
6.300
6.891
8.532
9.600
6.603
7.302
9.171
10.350
ROTOWIND | Air Curtains For Revolving Doors
WATER HEATED
Model
ROTO M 1000 P
ROTO M 1500 P
ROTO M 2000 P
ROTO M 2500 P
ROTO G 1000 P
ROTO G 1500 P
ROTO G 2000 P
ROTO G 2500 P
ROTO ECG 1000 P
ROTO ECG 1500 P
ROTO ECG 2000 P
ROTO ECG 2500 P
Airflow
m3/h
1860
2480
3720
4340
2250
3000
4500
5250
2550
3400
5100
5950
P86
Heating
Capacity
80/60ºC
kW
9,84
14,23
22,17
27,69
11,04
16,02
24,92
31,16
11,89
17,29
26,86
33,63
P64
Heating
Capacity
60/40ºC
kW
9,22
13,65
19,70
23,48
10,42
15,47
22,29
26,61
11,27
16,77
24,14
28,84
P54
Heating
Capacity
50/40ºC
kW
10,56
16,37
23,15
28,76
11,50
17,86
25,24
31,38
Power
Fans
230Vx1
kW
0,318
0,424
0,636
0,742
0,642
0,856
1,284
1,498
0,225
0,300
0,450
0,525
Current
Fans
230Vx1
A
1,41
1,88
2,82
3,29
2,85
3,80
5,70
6,65
1,95
2,60
3,90
4,55
Noise
Level
(5 m)
dB(A)
55
56
57
58
57
58
59
60
61
62
63
64
Weight
kg
-
Recom.
Height
Up to
m
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
P86
Price
euros
5.670
6.192
7.470
8.361
5.703
6.234
7.494
8.520
6.000
6.642
8.133
9.156
P64
Price
euros
5.757
6.288
7.632
8.586
5.787
6.330
7.656
8.730
6.087
6.738
8.295
9.381
P54
Price
euros
5.922
6.489
7.845
9.027
6.222
6.897
8.484
9.678
SLB
SPCT
Water heated: connection pipes P86 and P64 are 2x3/4” female (male if lateral pipes), P54 2x1” male. P86 2 rows coil, P64 3 rows coil, P54 4 rows coil.
Installation and Layouts
On top mounting
False ceiling mounting
Anchorage System
Anchored onto the door
Special Finishes
RAL chart
Stainless steel casing AISI 304
Hanging from the ceiling
Accessories
IR CONTROL CLEVER
IN-NE-II
DC
V-S/M
V-T
AFS-INS
35
VARIWIND | Modular, Variable Length Air Curtains
• Designed to be tailor-made, adaptable to any customer’s needs.
• Option VP: Structure made of aluminium profiles and galvanized steel panels,
finished white RAL 9016 as standard. Other colours are available on request. VP
construction allow the service from the top and the bottom. Large perforated inlet
grille avoiding intensive maintenance.
• Option VW: Same construction as Windbox M-ECM-G-ECG. Self-supporting
casing construction made of galvanized steel plate, finished in structural epoxypolyester painting white colour RAL9016 as standard. Other colours or stainless
steel are available on request. Micro-perforated inlet grille with filter functions and
easy service. It does not need prefilter.
• Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side
• Double-inlet centrifugal fans driven by an external rotor motor and low noise level.
5-speed selector. “EC” models assembled with very low consumption efficiency
fans.
• “P” type with water heated coil. “E” type with electrical shielded elements, three
stages with integrated regulation. “A” type without heating, air only. Optional
expansion DX coil.
• Includes Plug&Play control with 7m RJ45 cable and infrared remote control.
Optional: Clever control (programmable, automatic, intelligent, energy saving,
Modbus RTU for BMS…).
VP
(with profiles)
VW
(windbox construction)
AIR ONLY
Model
VARI M 1000 A
VARI M 1500 A
VARI M 2000 A
VARI M 2500 A
VARI ECM 1000 A
VARI ECM 1500 A
VARI ECM 2000 A
VARI ECM 2500 A
VARI G 1000 A
VARI G 1500 A
VARI G 2000 A
VARI G 2500 A
VARI ECG 1000 A
VARI ECG 1500 A
VARI ECG 2000 A
VARI ECG 2500 A
36
Airflow
m3/h
1800
2700
3600
4500
1840
2760
3680
4600
2400
3200
4800
5600
2700
3600
5400
6300
Power
Fans
230Vx1
kW
0,212
0,318
0,424
0.530
0,132
0,198
0,264
0,330
0,642
0,856
1,284
1,498
0,225
0,300
0,450
0,525
Current
Fans
230Vx1
A
0,94
1,41
1,88
2.35
1,14
1,71
2,28
2,85
2,85
3,80
5,70
6,65
1,95
2,60
3,90
4,55
Noise Level
(5 m)
dB(A)
55
56
57
58
56
57
58
59
57
58
59
60
61
62
63
64
Weight
kg
31
46
58
72
31
46
58
72
43
51
80
84
43
51
80
84
Recommended
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
Price
euros
2.874
3.384
3.909
4.557
3.093
3.693
4.341
5.103
3.105
3.633
4.377
5.025
3.405
4.017
4.992
5.742
VARIWIND | Modular, Variable Length Air Curtains
ELECTRICAL HEATED
Model
Airflow
m3/h
1800
2700
3600
4500
1840
2760
3680
4600
2400
3200
4800
5600
2700
3600
5400
6300
VARI M 1000 E
VARI M 1500 E
VARI M 2000 E
VARI M 2500 E
VARI ECM 1000 E
VARI ECM 1500 E
VARI ECM 2000 E
VARI ECM 2500 E
VARI G 1000 E
VARI G 1500 E
VARI G 2000 E
VARI G 2500 E
VARI ECG 1000 E
VARI ECG 1500 E
VARI ECG 2000 E
VARI ECG 2500 E
WATER HEATED
Model
VARI M 1000 P
VARI M 1500 P
VARI M 2000 P
VARI M 2500 P
VARI ECM 1000 P
VARI ECM 1500 P
VARI ECM 2000 P
VARI ECM 2500 P
VARI G 1000 P
VARI G 1500 P
VARI G 2000 P
VARI G 2500 P
VARI ECG 1000 P
VARI ECG 1500 P
VARI ECG 2000 P
VARI ECG 2500 P
Airflow
m3/h
1660
2490
3320
4150
1720
2580
3440
4300
2250
3000
4500
5250
2550
3400
5100
5950
P86
Heating
Capacity
80/60ºC
kW
9,17
14,26
20,65
26,92
9,38
14,58
21,12
27,53
11,04
16,02
24,92
31,16
11,89
17,29
26,86
33,63
Electrical Heating
Capacity
400Vx3-50Hz
kW
3/6/9
4/8/12
6/12/18
6/12/18
3/6/9
4/8/12
6/12/18
6/12/18
5/10/15
7,5/15/22,5
10/20/30
10/20/30
5/10/15
7,5/15/22,5
10/20/30
10/20/30
P64
Heating
Capacity
60/40ºC
kW
8,56
13,69
18,26
22,12
8,77
14,02
18,70
23,33
10,42
15,47
22,29
26,61
11,27
16,77
24,14
28,84
Power
Fans
230Vx1
kW
0,212
0,318
0,424
0,530
0,132
0,198
0,264
0,330
0,642
0,856
1,284
1,498
0,225
0,300
0,450
0,525
P54
Heatin
Capacity
50/40ºC
kW
8,52
14,34
18,65
24,32
8,74
14,71
19,13
24,95
10,56
16,37
23,15
28,76
11,50
17,86
25,24
31,38
Current
Fans
230Vx1
A
0,94
1,41
1,88
2,35
1,14
1,71
2,28
2,85
2,85
3,80
5,70
6,65
1,95
2,60
3,90
4,55
Power
Fans
230Vx1
kW
0,428
0,642
0,856
1,070
0,132
0,198
0,264
0,330
0,642
0,856
1,284
1,498
0,225
0,300
0,450
0,525
Current
Fans
230Vx1
A
1,90
2,85
3,80
4,75
1,14
1,71
2,28
2,85
2,85
3,80
5,70
6,65
1,95
2,60
3,90
4,55
Noise Level
(5 m)
dB(A)
55
56
57
58
56
57
58
59
57
58
59
60
61
62
63
64
Noise
Level
(5 m)
dB(A)
56
57
58
59
56
57
58
59
57
58
59
60
61
62
63
64
Weight
kg
37
57
75
94
37
57
75
94
52
63
100
106
52
63
100
106
Weight
kg
35
53
69
86
35
53
69
86
50
59
92
96
50
59
92
96
Recom.
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
Recommended
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
P86
Price
euros
3.159
3.726
4.335
5.211
3.366
4.023
4.737
5.742
3.387
3.972
4.779
5.655
3.669
4.329
5.367
6.351
Price
euros
3.705
4.305
4.941
5.892
3.915
4.614
5.373
6.444
3.972
4.617
5.754
6.813
4.260
4.983
6.366
7.533
P64
Price
euros
3.243
3.819
4.491
5.430
3.447
4.116
4.893
5.958
3.468
4.059
4.926
5.859
3.753
4.419
5.505
6.567
P54
Price
euros
3.378
3.978
4.680
5.727
3.582
4.275
5.082
6.255
3.603
4.218
5.115
6.156
3.888
4.578
5.694
6.864
Water heated: connection pipes P86 and P64 are 2x3/4” female (male if lateral pipes), P54 2x1” male. P86 2 rows coil, P64 3 rows coil, P54 4 rows coil.
Special Finishes
Painting according RAL chart
or metallic
Accessories
IR CONTROL CLEVER
CH-5HW-NE
TD-NE
IN-NE-II
DC
V-S/M
V-T
AFS-INS
SPWR
SLB
SPCT
37
KOOL | High Velocity Air Curtains For Cold Stores And Freezers
• Specially designed to be installed in doors of cold stores and freezers.
• Self-supporting casing construction made of galvanized steel plate, finished in
structural epoxy-polyester painting white colour RAL9016 as standard. Other
colours or stainless steel are available on request.
• Large perforated inlet grille avoiding intensive maintenance. Also available with
flat micro-perforated inlet grille, more elegant for commercial doors where heating
is not needed.
• Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side.
• Double-inlet centrifugal fans driven by an external rotor motor and low noise level.
5-speed selector. “EC” models assembled with very low consumption efficiency
fans.
• Includes Plug&Play control with 7m RJ45 cable and infrared remote control.
Optional: Clever control (programmable, automatic, intelligent, energy saving,
Modbus RTU for BMS…).
AIR ONLY
Model
Power
Fans
230V-50Hz
kW
0,212
0,318
0,424
0,530
0,636
0,132
0,198
0,264
0,330
0,396
0,642
0,856
1,284
1,498
1,712
0,225
0,300
0,450
0,525
0,600
Airflow
m3/h
1800
2700
3600
4500
5400
1840
2760
3680
4600
5520
2400
3200
4800
5600
6400
2700
3600
5400
6300
7200
KM 1000 A
KM 1500 A
KM 2000 A
KM 2500 A
KM 3000 A
KECM 1000 A
KECM 1500 A
KECM 2000 A
KECM 2500 A
KECM 3000 A
KG 1000 A
KG 1500 A
KG 2000 A
KG 2500 A
KG 3000 A
KECG 1000 A
KECG 1500 A
KECG 2000 A
KECG 2500 A
KECG 3000 A
Current
Fans
230V-50Hz
A
0,94
1,41
1,88
2,35
2,82
1,14
1,71
2,28
2,85
3,42
2,85
3,80
5,70
6,65
7,60
1,95
2,60
3,90
4,55
5,20
Noise Level
(5 m)
dB(A)
55
56
57
58
59
56
57
58
59
60
57
58
59
60
61
61
62
63
64
65
Weight
kg
29
44
53
58
76
33
50
61
68
76
37
55
71
78
86
37
56
71
78
86
Recommended
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
4,2
Special Finishes
Painting according RAL chart
or metallic
Stainless steel AISI 304
Accessories
IR CONTROL
38
CLEVER
IN-NE-II
DC
SPT3
SPWR
SLB
SPCT
SPF-KOOL
SPJ2-KOOL
Price
euros
1.383
1.692
2.061
2.583
3.573
1.614
2.040
2.535
3.168
4.275
1.626
1.944
2.523
3.045
4.050
1.935
2.364
3.174
3.807
4.908
TRIOJET SYSTEM |
Air Curtains Combination System with Multijets
For Large Cold Stores And Freezers
• Specially designed to be installed on doors of industrial cold stores and freezers with big temperature differences.
• Reduces mist, snow and ice decreasing risk of accidents.
• System composed by two air curtains: Special Duojet air curtain with plenum and Kool air curtain. The result is a combination system of 3 jets at
different temperatures and different speeds.
• High efficiency barrier against big amount of thermal losses due to a big temperature difference (shorter payback).
• Structure support with lateral walls to cover 100% of the opening with 3 jets should be provided by others.
• Self-supporting casing construction made of galvanized steel plate, finished in structural epoxy-polyester painting white colour RAL9016 as
standard. Other colours or stainless steel are available on request.
• Large perforated inlet grille avoiding intensive maintenance.
• Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side.
• Duojet with IP55 AC centrifugal fans and Kool with EC fans (both double inlet, external rotor motors and built-in thermal protection contact). All
provided with 5-speed selection, very low noise level.
• Includes electrical shielded element of 3 power stages with integrated regulation.
• Triojet is automatically fully controlled by Clever Control. Electronics and controller protected inside IP65 boxes. Plug & Play connections.
• Ready for BMS connection via Modbus RTU.
Model
TRIOJET 1000
TRIOJET 1500
TRIOJET 2000
TRIOJET 2500
TRIOJET 3000
Airflow
m3/h
5900
8400
11800
14300
16800
Fans
Power
230V-50Hz
kW
1,08
1,58
2,16
2,66
3,17
Fans
Current
230V-50Hz
A
5,75
8,30
11,50
14,05
16,60
Electrical Heating
Capacity
400Vx3-50Hz
kW
3/6/9
4/8/12
6/12/18
6/12/18
8/16/24
Noise Level
(5 m)
dB(A)
62
63
64
65
66
Weight
kg
125
182
234
275
314
Recommended
Height
Up to
m
3
3
3
3
3
Price
euros
consult
consult
consult
consult
consult
Special Finishes
Painting according RAL chart
or metallic
Stainless steel casing AISI 304
39
MAXWELL |
Air Curtains For Industrial Doors
• High performance industrial air curtains for vertical or horizontal installations for large
industrial doors. Available in 1.5, 2.0 and 2.5 meters length. Easy dockable modules
to reach large dimensions.
• Heavy self-supporting casing construction made of galvanized steel plate, finished in
structural epoxy-polyester painting white colour RAL9016 as standard. Other colours
are available on request.
• Double outlet with Coanda effect to achieve larger and efficient air jet. Anodized
aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side.
• High efficiency and low noise axial fans, driven with external rotor motor single phase
230V. Optionally three phase 400V. Provided with 5-speed selection. Maintenance free.
• “P” type with water heated coil. “A” type without heating, air only.
• Regulation not included. Optional:
Basic regulation with Plug&Play control panel, 10m RJ45 cable and remote control.
Advanced regulation with Clever (automatic, intelligent, energy saving, Modbus RTU
for BMS…).
AIR ONLY
Model
MXW 1500 A
MXW 2000 A
MXW 2500 A
Airflow
m3/h
7000
10500
14000
WATER HEATED
Model
MXW 1500 P
MXW 2000 P
MXW 2500 P
Power
Fans
230V-50Hz
kW
0,68
1,02
1,36
Airflow
m3/h
6800
10200
13600
P86
Heating
Capacity
80/60ºC
kW
41,39
61,25
80,05
Current
Fans
230V-50Hz
A
2,96
4,44
5,92
P64
Heating
Capacity
60/40ºC
kW
34,09
50,16
66,19
Power
Fans
230Vx1
kW
0,68
1,02
1,36
Noise Level
(5 m)
dB(A)
60
61
62
Current
Fans
230Vx1
A
2,96
4,44
5,92
Noise
Level
(5 m)
dB(A)
59
60
61
Weight
kg
79
103
126
Weight
kg
95
126
158
Recommended
Height
Up to
m
6
6
6
Recom.
Height
Up to
m
6
6
6
P86
Price
euros
2.520
3.342
4.185
Price
euros
2.130
2.829
3.543
P64
Price
euros
2.637
3.516
4.392
Water heated: P86 2 rows coil, P64 3 rows coil. Electrical heated models available on customer request. Let us know your needs.
Special Finishes
Painting according RAL chart
or metallic
Accessories
IR CONTROL CLEVER
40
CH-5HW-NE
IN-NE-II
DC
V-S/M
V-T
AFS-INS
SPWR
SLB/SPCT SPF-MXW
SPJ2-MXW
MAX |
Air Curtains For Industrial Doors
• High performance industrial air curtains for vertical or horizontal installations for large
industrial doors. Easy dockable modules to reach large dimensions.
• Heavy casing made of double chamber aluminium profiles and galvanized plated
steel panels, finished in structural epoxy-polyester painting white colour RAL9016
as standard. Other colours are available on request.
• Double outlet with Coanda effect to achieve larger and efficient air jet. Anodized
aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side.
• High efficiency and low noise axial fans, driven with external rotor motor single phase
230V. Optionally three phase 400V. Provided with 5-speed selection. Maintenance free.
• “P” type with water heated coil. “E” type with electrical shielded elements, three
stages with integrated regulation. “A” type without heating, air only.
• Includes Plug&Play control with 10m RJ45 cable and infrared remote control.
Optional: Clever control (programmable, automatic, intelligent, energy saving,
Modbus RTU for BMS…).
AIR ONLY
Model
MAX 2 A
MAX 3 A
MAX 4 A
MAX 5 A
MAX 6 A
Airflow
m3/h
6600
9900
13200
16500
19800
Power
Fans
230V-50Hz
kW
0,68
1,02
1,36
1,70
2,04
Airflow
m3/h
6600
9900
13200
16500
19800
Electrical Heating
Capacity
400Vx3-50Hz
kW
15/25/40
22,5/37,5/60
30/50/80
30/60/90
30/60/90
ELECTRICAL HEATED
Model
MAX 2 E
MAX 3 E
MAX 4 E
MAX 5 E
MAX 6 E
WATER HEATED
Model
MAX 2 P
MAX 3 P
MAX 4 P
MAX 5 P
MAX 6 P
Airflow
m3/h
6400
9600
12800
16000
19200
P86
Heating
Capacity
80/60ºC
kW
28,74
51,77
74,15
96,43
118,69
P64
Heating
Capacity
60/40ºC
kW
29,71
47,10
63,30
82,16
91,92
Current
Fans
230V-50Hz
A
2,96
4,44
5,92
7,40
8,88
Power
Fans
230V-50Hz
kW
0,68
1,02
1,36
1,70
2,04
Noise Level
(5 m)
dB(A)
62
63
64
65
66
Current
Fans
230V-50Hz
A
2,96
4,44
5,92
7,40
8,88
Power
Fans
230Vx1
kW
0,68
1,02
1,36
1,70
2,04
Current
Fans
230Vx1
A
2,96
4,44
5,92
7,40
8,88
Noise Level
(5 m)
dB(A)
62
63
64
65
66
Noise
Level
(5 m)
dB(A)
61
62
63
64
65
Weight
kg
59
79
103
124
151
Weight
kg
74
100
133
159
186
Weight
kg
75
102
135
162
189
Recommended
Height
Up to
m
6
6
6
6
6
Recommended
Height
Up to
m
6
6
6
6
6
Recom.
Height
Up to
m
6
6
6
6
6
P86
Price
euros
3.939
4.938
6.066
7.299
9.186
Price
euros
2.739
3.576
4.380
5.355
6.912
Price
euros
5.842
7.239
8.385
9.802
12.221
P64
Price
euros
4.296
5.475
6.738
8.079
10.074
Water heated: P86 2 rows coil, P64 3 rows coil.
Special Finishes
Painting according RAL chart
or metallic
Accessories
IR CONTROL CLEVER
CH-5HW-NE
TD-NE
IN-NE-II
DC
V-S/M
V-T
AFS-INS
SPWR
SLB/SPCT SPF-MAX
SPJ2-MAX
41
Compact Recessed High Velocity Air Curtains
RECESSED COMPACT | For Commercial and Industrial Doors
• Compact and low profile air only recessed air curtain, with full grille view, specially
designed for applications without heating.
• Self-supporting casing construction made of galvanized steel plate, ready to be
installed recessed in a false ceiling.
• Inlet grille (free of maintenance) made with aluminium profiles and blow-out
nozzle, integrated in a single white frame colour RAL 9016. Other colours are
available on request.
• Anodized aluminium outlet vanes, airfoil shaped, adjustable in both directions.
• Double-inlet centrifugal fans driven by an external rotor motor and low noise level.
5-speed selector. “EC” models assembled with very low consumption efficiency fans.
• Includes Plug&Play control with 7m RJ45 cable and infrared remote control.
Optional: Clever control (programmable, automatic, intelligent, energy saving,
Modbus RTU for BMS…).
AIR ONLY
Model
RC M 1000 A
RC M 1500 A
RC M 2000 A
RC M 2500 A
RC ECM 1000 A
RC ECM 1500 A
RC ECM 2000 A
RC ECM 2500 A
RC G 1000 A
RC G 1500 A
RC G 2000 A
RC G 2500 A
RC ECG 1000 A
RC ECG 1500 A
RC ECG 2000 A
RC ECG 2500 A
Airflow
m3/h
1800
2700
3600
4500
1840
2760
3680
4600
2400
3200
4800
5600
2700
3600
5400
6300
Power
Fans
230V-50Hz
kW
0,212
0,318
0,424
0,530
0,132
0,198
0,264
0,330
0,642
0,856
1,284
1,498
0,225
0,300
0,450
0,525
Current
Fans
230V-50Hz
A
0,94
1,41
1,88
2,35
1,14
1,71
2,28
2,85
2,85
3,80
5,70
6,65
1,95
2,60
3,90
4,55
Noise
Level
(5 m)
dB(A)
55
56
57
58
56
57
58
59
57
58
59
60
61
62
63
64
Recommended
Height
Up to
m
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,8
3,8
3,8
3,8
4,2
4,2
4,2
4,2
Weight
kg
33
50
61
68
33
50
61
68
37
55
71
78
37
56
71
78
Special Finishes
Inlet and outlet grille painting
according RAL chart or metallic
Accessories
IR CONTROL
42
CLEVER
IN-NE-II
DC
SPWR
SLB
SPCT
SPANG-SIL
Price
euros
1.683
2.121
2.547
2.976
1.905
2.457
2.961
3.501
1.914
2.379
3.015
3.456
2.211
2.766
3.579
4.119
ACCESSORIES
Feet, wall or celing supports, tailor made arms, vibration dampers…
Thermostatic valve, solenoid valve (ON/OFF), modulating valves...
Anti-freeze sensor, door contact, ambient thermostat, external temperature sensor…
Telephone cables: RJ45, RJ11, different lengths...
SPECIAL OPTIONS
Airtècnics, as an air curtains specialist, can produce units with special requirements under request.
Here there are some of the possibilities:
• External alarm signals as: unit working, heating ON, airflow switch, dirty grille, electronic overheating signal, fans overheating thermo contact TK,
electrical heating blocked, etc.
• Special water or steam coils for higher temperatures or different power than standard
• Tailor made electrical heating elements at desired power and power supply
• Electrical heated air curtains from 400Vx3 to 230Vx3 or 230Vx1
• Dummies (empty air curtains) to combine with working units
• Industrial air curtains at 400Vx3 with the same advantages of electronic regulation 5 speed range
• Industrial MAX with higher volume (MAX L)
• Industrial MAX with explosion proof EX fans
• Stainless steel AISI-316 or other materials under request
• Special RAL colour wiht gloss or other finishes. Special BS (British Standard), Tiger Drylac, etc.
• Complete tailor made air curtain or our standard range customized according to client needs
Please consult us for further information or other options.
43
BASIC REGULATION: Standard Controls
Two ranges of control panels, both designed for easy and quick Plug & Play connection, free of mistakes, by using a telephone cable with RJ45
connectors. The digital communication between the control panel and air curtain is a very reliable connection without information losses even at long
distances. All control panels can be turned ON/OFF externally and have internal memory (if the power supply is cut off, the unit goes back to the
selected state).
2-Speed Range Controls
Suitable for Optima and Recessed Optima air curtains. Infrared remote control included.
CW-2EV-IR
Water heated
2 fan speed and
electro-valve switch
CA-2AO-IR
Only air and
water heated
2 fan speed
CE-2AO-IR
Electrical heated
2 fan speed
2 heating stages
5-Speed Range Controls
Suitable for Windbox M,ECM,G,ECG,L,XL, Dam, Smart, Recessed Windbox, Recessed Dam, Recessed Compact, Kool, Zen, Rund, Deco, Rotowind,
Invisair, Variwind, Max and Maxwell air curtains. Infrared remote control included.
CA-5AW-IR
Only air
5 fan speed
CW-5AW-IR
Water heated, 5 fan speed
and electro-valve switch
CE-5AW-IR
Electrical heated, 5 fan speed
and 3 heating stages
CD-5AW-IR
Heat pump heated, 5 fan speed
and heating ON/OFF
Optional Controls
Hand Auto
Water heated: with manual and automatic operating.
Auxiliary functions: anti-freezing sensor, door contact
(with delay) and room thermostat.
CH-2HO-NE
CH-5HW-NE
Digital Thermostat
Only electrical heated: modifies heat
stages and fan speed depending on
temperature and selected program.
TD-NE
Interface
Allows the connection to a centralized
management system like BMS and
also to standard controllers.
IN-NE-II
Multiple connection
Easy to manage several units using only one control panel.
44
ADVANCED REGULATION: Clever Control
The future is here with the new generation Clever control. Maximum control with maximum energy saving.
Intelligent
PCB Box
Clever Control automatically adapts the functioning of the air
curtain to the entrance conditions, mantainig comfort while
saving energy. It optimizes the ventilation and heating to
make an efficient barrier for an optimal climate separation.
Air Curtain
Outdoor
Temperature
Indoor
Temperature
Door
State
Intelligent
Proactive
Regulation
Clever
Control
It includes manual or automatic functioning with many different
programs depending on heating type (water, electrical, heat
pump or unheated) and installed temperature sensors.
Clever kit includes:
PCB Power Supply
Clever Control
Outdoor Temperature
Sensor
- Color TFT screen 2.8 inch
- 114 (h) x 85 (w) x 14 (d) mm
- Prepared for flush-mount installation
- Input: 100-240Vx1 50/60Hz (AC)
- Output: 24V 2A (DC)
- EU 2 pins / BS 3 pin plugs
Intelligent PCB Box
RJ11 + RJ45 Cables
Door Contact
- Easy Plug & Play installation
- RJ11 (4 Pins), 7m length
- RJ45 (8 Pins), 3m length
- Monitoring Door Status
- Magnetic contact
- Electronic PCB Regulation
- 218 (w) x 140 (h) x 64 (d) mm
- Varnish Protection
SPECIAL CONNECTION
- Real-time temperature values
- IP65 Protection
SPECIAL CONNECTION
RJ45 CABLE
RJ11 CABLE
8 PINS CONNECTOR
4 PINS CONNECTOR
INTELLIGENT
PCB BOX
OUTDOOR
TEMPERATURE
SENSOR
DOOR
CONTACT
CLEVER
CONTROL
PCB POWER SUPPLY
100 - 240Vx1 50/60 Hz
AIR CURTAIN
SIMPLE INSTALLATION
Plug & Play
Factory adjusted
control to just
switch on and run
45
CONTROLLERS AND REGULATION
Hand/Auto Control
Digital Thermostat
For air curtains with water heating. Manual or
automatic operating. It permits to program the
equipment according to auxiliary sensors: ambient
thermostat, door contact, anti-freeze sensor, etc.
For air curtains with heating through electrical
resistances.
Modifies the heating stages and the ventilation
speed according to temperature and selected
program. It permits the operating with a door contact.
Price
Euros/Ut.
Model
CH-5HW-NE
CH-2HO-NE
180
180
Clever Control automatically adapts the
functioning of the air curtain to the entrance
conditions, maintaining comfort while saving
energy. It optimizes the ventilation and heating
to make an efficient barrier for an optimal climate
separation.
It allows the connection to a centralised
management system like BMS.
Price
Euros/Ut.
450
158
292
Price
Euros/Ut.
Model
IN-NE-II
89
IR Control
Ambient Thermostat
Infrared remote controller for all models.
(except Minibel)
To control the equipment according to the selected
temperature.
Price
Euros/Ut.
Model
IR CONTROL AIR
46
143
Interface connection BMS
CLEVER KIT
CLEVER TFT
CLEVER PCB + DC
TS
TD-NE
Clever Control
Model
Model
Price
Euros/Ut.
Model
30
Price
Euros/Ut.
Model
TA-1002
36
External sensor
Plug&Play Cable
It permits to measure the temperature in a different
room that the one that is controlled.It is compatible
with digital thermostat TD and Clever Control.
Connexion cable between the controller and the air
curtain. CB4/7/20/50 of 4, 7, 20 and 50 meters.
Price
Euros/Ut.
22
Model
Price
Euros/Ut.
CB4
CB7
CB20
CB50
16
20
30
68
CONTROLLERS AND REGULATION
Solenoid Valve
Modulating Valve
It turns ON/OFF the heating by opening or closing
the hot water inlet valve to the water coil.
The air curtain supplies 230Vx1 to open the valve.
It allows the opening of the valve from 0 to 100%
to modulate the heating. Regulating the heating
proportionally, you can adjust the temperature better
while achieving higher energy saving.
Price
Euros/Ut.
Model
V-S 3/4"
V-S 1"
V-S 1-1/4"
V-S 1-1/2"
144
223
741
507
Model
Price
Euros/Ut.
V-M
consult
3 ways thermostatic valve
Anti-freezing sensor
It allows a proportional control of the outlet air
temperature.
It protects the equipment in case of freezing of the
water coil. AFS model not mounted, AFS-INS model
mounted in the air curtain.
Price
Euros/Ut.
Model
V-T DN20 3/4” (and 1/2”)
V-T DN25 1"
V-T DN40 1-1/2”
334
374
588
Model
AFS-5-INS LONG<2000
AFS-1-INS LONG>=2000
AFS-5 (sensor 3m)
AFS-1 (sensor 6m)
Price
Euros/Ut.
206
209
146
146
Door contact
To operate the equipment according to the state of
the door (open/closed).
MAG model, magnetic contact, MEC model
mechanical contact.
Model
DC-MAG
DC-MEC
Price
Euros/Ut.
18
102
47
SUPPORTS
Wall Support
Vibration Dampers
To anchor the air curtains to the wall, for
following models: Kool (SPT3), Optima (SPT2)
and Minibel (SPT1).
It attenuates possible vibrations and avoids the
transmission of sound frequencies.
Model
Price
Euros/Ut.
SPT1
SPT2
SPT3
12
13
13
SLB-M8
SLB-M10
8
23
Tension Support
Angle Support
Stainless cable of easy installation with shackle.
Threaded end M8/10, of 1 or 5 meters (1M/5M).
Other lengths under request.
Angle support with silenblock to attenuate possible
vibrations and avoid the transmission of sound
frequencies. Ideal for recessed units.
Price
Euros/Ut.
Model
SPCT-M8 1M
SPCT-M8 5M
SPCT-M10 1M
SPCT-M10 5M
14
22
36
51
Price
Euros/Ut.
Model
SPANG-SIL
2
Universal Simple Support
Universal Wall Support VR
It allows the hanging installation for any type of air
curtains. Available in different lengths, for all models.
It allows the hanging installation for any type of
air curtains. It incorporates a vertical guide rail to
increase the anchor area.
Available in different lengths, for all models.
Price
Euros/Ut.
Model
SPWR-360
SPWR-400
SPWR-600
SPWR-720
32
31
50
61
SPWR-600 VR
SPWR-720 VR
SPWR-800 VR
SPWR-1040 VR
SPF-KOOL
SPF-M,ECM,G,ECG,DAM
SPF-L,XL
SPF-RUND
SPF-ZEN
SPF-MAX
SPF-INVISAIR
SPF-MXW
SPF-KOOL S/S
SPF-M,ECM,G,ECG,DAM S/S
SPF-L,XL S/S
SPF-RUND S/S
SPF-ZEN S/S
Price
Euros/Ut.
73
73
192
246
323
97
81
97
233
251
343
342
468
70
80
83
166
Installation Kit for 2 Air Curtains
pilled up in Vertical
To join two units and its anchor to the wall.
S/S Models in Stainless Steel.
For air curtain vertical mounting. Includes metal
pieces for floor anchor.
S/S Models in Stainless Steel.
Model
Price
Euros/Ut.
Model
Feet for Vertical Installation
48
Price
Euros/Ut.
Model
Model
SPJ2-KOOL
SPJ2-M,ECM,G,ECG,DAM
SPJ2-RUND
SPJ2-L,XL
SPJ2-MAX
SPJ2-INV
SPJ2-MXW
SPJ2-M,ECM,G,ECG,DAM S/S
Price
Euros/Ut.
62
62
100
178
86
86
86
283
SUPPORTS
Rund Angle Support Tailor-made
Joinning & Rund Support
Rund air curtain anchors for lateral wall or ceiling.
They are custom-made (the number indicates the
maximum distance between the center of the air
curtain and the wall or ceiling).
S/S Models in Stainless Steel.
To join and support 2 Rund air curtains. They are
custom-made (number indicates maximum distance
between center of air curtain and wall/ceiling). Thus,
it is possible to join several air curtains to obtain all
lengths.
S/S Models in Stainless Steel.
Price
Euros/Ut.
Model
SPANG-RUND-500
SPANG-RUND-1000
SPANG-RUND-1500
SPANG-RUND-500 S/S
SPANG-RUND-1000 S/S
SPANG-RUND-1500 S/S
531
663
773
754
919
1.079
Price
Euros/Ut.
Model
SPANG-INT-RUND-500
SPANG-INT-RUND-500 S/S
333
675
Arm/Goalpost Rund Tailored
Rund Straight Arm Tailor-made
Anchorage for the lateral of Rund air curtains to wall,
ceiling or floor (goalpost).
It is tailor-made (the number indicates the max.
length of the arm).
S/S Models in Stainless Steel.
Rund air curtain anchors for lateral walls. They are
tailor-manufactured (the number indicates the
maximum distance between the center of the air
curtain and the wall).
S/S Models in Stainless Steel.
Price
Euros/Ut.
Model
SPARM-90-1000
SPARM-90-1500
SPARM-90-2000
SPARM-90-2500
SPARM-90-3000
SPARM-90-3500
SPARM-90-1000 S/S
SPARM-90-1500 S/S
SPARM-90-2000 S/S
SPARM-90-2500 S/S
SPARM-90-3000 S/S
SPARM-90-3500 S/S
1.236
1.355
1.479
1.603
1.742
1.910
1.343
1.583
1.823
2.063
2.163
2.543
Model
SPARM-180-1000
SPARM-180-2000
SPARM-180-1000 S/S
SPARM-180-2000 S/S
Price
Euros/Ut.
699
1.025
849
1.049
Optima Joint
To join 2 or more optima air curtains making all
lengths possible.
Model
RNG 20/30
Price
Euros/Ut.
15
49