Airtècnics
Transcription
Airtècnics
AIRTECNICS: The Air Curtain Specialist Founded in 1986 and placed in Castellar del Vallès (Barcelona), Airtècnics has a large experience producing air curtains, air handling units, fan boxes, fan filter units, axial fans, centrifugal fans and other special and OEM equipment. We export our products to more than 45 countries worldwide. Besides our own production, Airtècnics distributes a wide range of HVAC products, mostly produced by Rosenberg Group companies. Loyal to our commitments regarding our customers, our products fulfill the highest standards of quality criteria. We are proud of our highly qualified team composed by master engineers, designers, specialized technicians and skilled professionals, ready to assist you in any questions you may have in design, installation or service maintenance requirements. Be sure that Airtècnics or our worldwide distributors network will give you the right solution for any air curtains application. • Air curtains market leading • Producing +20 years • Exporting +45 countries • Catalogue +25 languages www.airtecnics.com Find more information and our distributors list in our specialized air curtain websites: Latvian www.gaisaaizkari.com Catalan www.cortinesaire.com Lithuanian www.orouzuolaidos.com Czech www.vzduchoveclony.com Norwegian www.luftporter.com Danish www.lufttaepper.com Polish www.kurtynapowietrzna.com Dutch www.luchtgordijnen.com Portuguese www.cortinadear.com English www.dooraircurtain.com Romanian www.perdeledeaer.com Finnish www.ilmaverho.com Russian www.vozdushnyezavesy.com French www.rideauxdair.com Serbian www.vazdusnezavese.com German www.luftschleieranlagen.net Slovenian www.zracnezavese.com Greek Bulgar Airtècnics headquarters in Castellar del Vallès (Spain) • Experimented R+D+i • Continuous improving • Complete range, all applications • University knowledge collaboration www.vazdushnizavesi.com www.aerokourtines.com Spanish www.cortinasdeaire.es Hungary www.legfuggonyok.com Swedish www.luftridaer.com Italian Turkish www.havaperdeleri.eu www.barrieradaria.com The Rosenberg Group Airtècnics is from 1993 fully integrated in the Rosenberg Group, an organization specializing in the design, manufacturing and distribution of equipments and components of ventilation and air conditioning with factories, subsidiaries and agencies in more than 50 countries. Founded in 1981, with a total of 1.400 employees, 14 production sites on 4 continents, as well as 4 development centres. Rosenberg develops, produces and distributes its products worldwide. Through a combination of human know how and innovative production technology Rosenberg products achieve a quality which meets the highest requirements. Rosenberg headquarters in Künzelsau (Germany) 2 AIR CURTAINS The new and attractive generation of Airtècnics air curtains are the ideal solution to maintain a comfortable interior climate in commercial outlets and public buildings that need to keep their doors open. The end result is more customers and an increase in sales. Airtècnics air curtains are a protection from the cold and heat, repel gusts of wind and minimize dust, fumes, pollution and insects entering the building. Airtècnics air curtains create an air stream layer over the doorway and act as an invisible barrier which efficiently divides the inside environment from the outside one. Therefore, it substantially reduces heating and cooling costs up to 80%, while increasing employees and clients comfort. In order to obtain these advantages it’s very important to choose the appropriate air curtain. Factors such as interior drop, strong winds, the door’s location, stairs between floors, opposite doors, and the installation height have to be taken into consideration. For shops, Airtècnics air curtains allow a clear view of the inside of the shop, welcoming the client to enter easily and freely. Decorative Standard Heat Pump Revolving Doors Air curtains Air curtains Air curtains Recessed Air curtains Our expert consultants with their extensive experience are at your disposal to help you choose. Air curtains Industrial Air curtains Advantages MAINTAIN: PROTECT FROM: - Heating levels - Refrigeration - Air conditioning - Comfort - Clean atmosphere - Cold winter temperatures - Hot summer temperatures - Car fumes - Dust in the air - Pollution - Bad smells and odours - Insects Selection of an air curtain To select an air curtain the following factors have to be kept in mind: - - - - - - - - - - The height of the installation measured from the discharge diffuser to the floor The width of the door The location of the building to determine the level of protection needed against weather conditions If the building has several doors in the same, different or opposite facade If the building has several stores connected by escalators Pressure differences between the inside and outside of the building Door characteristics: if always open, if automatic door, manual door, revolving door, etc. Characteristics of the ventilation and air conditioning installation Voltage and electrical power availability Type of business, style and decoration of the premises www.dooraircurtain.com 3 WIDE RANGE Applications Model Kind Optima Optima Wireless Recessed Optima Windbox Recessed Windbox Smart M, ECM Zen Rund Deco Dam G Recessed Dam Windbox DX Invisair Rotowind ECG Variwind Recessed Compact (A) Kool (A) Triojet Maxwell Max A Heating E P Common Applications • • Kiosks, Fast Food and small sized shops. Restaurants and places with usually closed door or automatic door when low pedestrian flow. 2,2 - 2,8 m • • • Small and medium sized premises. Restaurants, shops and places with a medium and high pedestrian flow. Creation of different environment zones. Protection against dust, fumes, pollutants and insects. False ceiling installations. Isolation and sealing of smoking areas. 2,5 - 3,5 m • • • Up to 1,8 m Minibel Windbox Recommended Installation Height (*) 3,0 - 3,8 m • • • 3,2 - 4,2 m • • • 2-3m L 4-5m XL 5-7m 4-6m • • • • • • • • • • • • Medium and large sized premises with a high pedestrian flow. Protection against dust, fumes, pollutants and insects. Cold rooms. False ceiling installations. Isolation and sealing of smoking areas. Industrial doors for large cold rooms and freezers with very low temperatures or problems with ice production. Medium and large sized premises with a high pedestrian flow. Industrial doors. Protection against dust, fumes, pollutants and insects. Cold rooms. False ceiling installations. Industrial doors. Loading dock. Vertical Installation to one side of the door or at each side of the door. Horizontal Installation. (*) The maximum height of installation depends on the conditions of the premises. Contact us to clear up your queries or doubts. (A) Air Only, (E) Electrical Heating, (P) Water Coil Heating LPHW. 4 INDEX | Air Curtains Wide Range For All Applications 6 MINIBEL WINDBOX L, XL 30-31 High pressure for commercial and large industrial doors 4 - 7 m Economical for openings up to 1,8 m OPTIMA WIRELESS 7 INVISAIR Recessed in column or bulkhead For commercial doors 2,2 - 2,8 m 32-33 vertical or horizontal 2,5 - 4,2 m 8 OPTIMA For commercial doors 2,2 - 2,8 m ROTOWIND 34-35 VARIWIND 36-37 Tailor made for revolving doors 2,5 - 4,2 m RECESSED OPTIMA 9 For commercial doors 2,2 - 2,8 m recessed installation in false ceiling WINDBOX M, ECM, G, ECG 10-11 Tailor made variable length VP or VW construction 2,5 - 4,2 m High pressure for commercial and industrial doors 2,5 - 4,2 m RECESSED WINDBOX 12-13 KOOL 38 TRIOJET SYSTEM 39 MAXWELL 40 High velocity for cold store and freezer doors 2,5 - 4,2 m High pressure for commercial doors recessed installation in false ceiling 2,5 - 4,2 m SMART 14-15 Combination system with multijets for large cold stores 2 - 3 m Decorative high pressure for commercial and industrial doors 2,5 - 4,2 m ZEN Customizable design with bespoke panels for commercial doors 2,5 - 4,2 m 16-17 Large industrial doors vertical or horizontal 4 - 6 m MAX RUND 18-19 DECO 20-21 Decorative cylindrical for vertical or horizontal installation 2,5 - 4,2 m RECESSED COMPACT Decorative with aluminium profiles for commercial doors 2,5 - 4,2 m DAM 22-23 High pressure for commercial doors with front panel 2,5 - 4,2 m RECESSED DAM 24-25 Compact recessed for commercial and industrial doors 2,5 - 4,2 m HEAT PUMP AIR CURTAINS 26-29 Energy saving and very low consumption technology for commercial doors 2,5 - 4,2 m 41 Large industrial doors vertical or horizontal 4 - 6 m 42 Air only compact recessed for commercial and industrial doors 2,5 - 4 ,2m ACCESSORIES SPECIAL OPTIONS 43 Valves, sensors, etc. REGULATION 44-47 SUPPORTS 48-49 Basic regulation: standard controls Advanced regulation: Clever control Controllers and regulation Standard or Tailor made 5 MINIBEL | Air Curtains For Commercial Doors • Self-supporting casing construction made of galvanized steel plate, finished in structural epoxy-polyester painting white colour RAL9016 as standard. Other colours are available on request. • Anodized aluminium outlet vanes, airfoil shaped. • Compact axial fans, low noise level. • “E” type with electrical shielded element. “A” type without heating, air only. • Integrated switch for ventilation and heating control. • Cable connection 1,5m length, integrated. • Wall support included. Model MINIBEL 600 A MINIBEL 600 E MINIBEL 900 A MINIBEL 900 E 6 Airflow m3/h Power 1x230V kW Noise Level dB(A) Weight kg Recommended Height up to m Price euros 420 420 630 630 2,5 3,2 46 46 47 47 9 10 12,5 13,5 1,8 1,8 1,8 1,8 315 384 414 498 OPTIMA WIRELESS | Air Curtains For Commercial Doors • Self-supporting casing construction made of galvanized steel plate, finished in structural epoxy-polyester painting white colour RAL9016 as standard. Other colours are available on request. • Micro-perforated inlet grille with filter functions and easy service. It does not need prefilter. • Anodized aluminium outlet vanes, airfoil shaped. • Low noise twisted cross-flow fans driven by a 2-speed external rotor motor. • “E” type with electrical shielded elements, two stages with integrated regulation. “A” type without heating, air only. • Included regulation with infrared remote control and inbuilt keypad with leds. AIR ONLY Model OPT W 1000 A OPT W 1500 A OPT W 2000 A Airflow m3/h 1500 2150 2900 Noise Level (5 m) dB(A) 35/50 36/51 38/53 Weight kg 17,5 25,5 33 Recom. Height Instal. m 2,8 2,8 2,8 Airflow m3/h 1500 1500 2150 2150 2150 2900 2900 Electrical Heating Capacity (*) kW 4/6 3,8/5,6 6/9 3,8/5,6 6/9 5,6/11,3 5,6/11,3 Electrical Heating Voltage V 400Vx3 230Vx1 400Vx3 230Vx1 230Vx1 400Vx3 230Vx1 Electrical Heating Current A 5,8/8,7 16,5/24,5 8,7/13 16,5/24,5 26/39,1 8,1/16,3 24,5/49,1 ELECTRICAL HEATED Model OPT W 1000 E OPT W 1000 E230 OPT W 1500 E OPT W 1500 E230-6 OPT W 1500 E230-9 OPT W 2000 E OPT W 2000 E230 Price euros 688 826 1.234 Noise Level (5 m) dB(A) 35/50 35/50 36/51 36/51 36/51 38/53 38/53 Weight kg 20,5 20,5 27,5 27,5 27,5 42 42 Recom. Height Up to m 2,8 2,8 2,8 2,8 2,8 2,8 2,8 Price euros 862 862 1.032 1.032 1.032 1.596 1.596 Accessories IR CONTROL SPT2 SPWR SLB SPCT RNG 20/30 7 OPTIMA | Air Curtains For Commercial Doors • Self-supporting casing construction made of galvanized steel plate, finished in structural epoxy-polyester painting white colour RAL9016 as standard. Other colours are available on request. • Micro-perforated inlet grille with filter functions and easy service. It does not need prefilter. • Anodized aluminium outlet vanes, airfoil shaped. • Low noise twisted cross-flow fans driven by a 2-speed external rotor motor. • “P” type with water heated coil. “E” type with electrical shielded elements, two stages with integrated regulation. “A” type without heating, air only. • Includes Plug&Play control with 7m RJ45 cable and infrared remote control. Optional: Clever control (programmable, automatic, intelligent, energy saving, Modbus RTU for BMS…). AIR ONLY Model OPT 1000 A OPT 1500 A OPT 2000 A Airflow m3/h 1500 2150 2900 Noise Level (5 m) dB(A) 35/50 36/51 38/53 Weight kg 17,5 25,5 33 WATER HEATED P86 Recom. Height Instal. m 2,8 2,8 2,8 Price euros 819 957 1.365 Model OPT 1000 P OPT 1500 P OPT 2000 P Airflow m3/h 1400 2100 2750 Heating Capacity 80/60ºC kW 8,2 12,7 16,7 Noise Level (5 m) dB(A) 37/51 38/52 40/54 Weight kg 20,5 27,5 37,5 Recom. Height Up to. m 2,8 2,8 2,8 Price euros 1.116 1.350 1.878 Water heated: connection pipes 1/2’’ female. 2 rows coil. ELECTRICAL HEATED Model OPT 1000 E OPT 1000 E-9 OPT 1000 E230 OPT 1500 E OPT 1500 E230-6 OPT 1500 E230-9 OPT 2000 E OPT 2000 E230 Airflow m3/h 1500 1500 1500 2150 2150 2150 2900 2900 Electrical Heating Capacity (*) kW 4/6 6/9 3,8/5,6 6/9 3,8/5,6 6/9 5,6/11,3 5,6/11,3 Electrical Heating Voltage V 400Vx3 400Vx3 230Vx1 400Vx3 230Vx1 230Vx1 400Vx3 230Vx1 Electrical Heating Current A 5,8/8,7 8,7/13 16,5/24,5 8,7/13 16,5/24,5 26/39,1 8,1/16,3 24,5/49,1 Noise Level (5 m) dB(A) 35/50 35/50 35/50 36/51 36/51 36/51 38/53 38/53 Weight kg 20,5 21,5 20,5 27,5 27,5 27,5 42 42 Recom. Height Up to m 2,8 2,8 2,8 2,8 2,8 2,8 2,8 2,8 Price euros 1.133 1.212 1.198 1.328 1.388 1.417 2.010 2.184 SPCT RNG 20/30 (*) Under request other electrical heating capacities may be supplied. Special Finishes Painting according RAL chart or metallic Accessories IR CONTROL CLEVER 8 TD-NE IN-NE-II DC V-S/M V-T SPT2 SPWR SLB RECESSED OPTIMA | Recessed Air Curtains For Commercial Doors • Self-supporting casing construction made of galvanized steel plate, ready to be installed recessed in a false ceiling. • Inlet grille (free of maintenance) made with aluminium profiles and blow-out nozzle, integrated in a single white frame colour RAL 9016. Other colours are available on request. • Anodized aluminium outlet vanes, airfoil shaped. • Low noise twisted cross-flow fans driven by a 2-speed external rotor motor. • “P” type with water heated coil. “E” type with electrical shielded elements, two stages with integrated regulation. “A” type without heating, air only. • Includes Plug&Play control with 7m RJ45 cable and infrared remote control. Optional: Clever control (programmable, automatic, intelligent, energy saving, Modbus RTU for BMS…). AIR ONLY Model RO 1000 A RO 1500 A RO 2000 A Airflow m3/h 1700 2200 3200 Noise Level (5 m) dB(A) 35/50 36/51 38/53 Weight kg 24 34 44,5 Recom. Height Up to m 2,8 2,8 2,8 WATER HEATED P86 Price/Unit euros 1.080 1.254 1.782 Model RO 1000 P RO 1500 P RO 2000 P Airflow m3/h 1450 2175 2850 Heating Capacity 80/60ºC kW 8,3 13 17,1 Noise Level (5 m) dB(A) 37/51 38/52 40/54 Recom. Height Up to m 2,8 2,8 2,8 Weight kg 26,5 37,5 49 Price euros 1.377 1.647 2.295 Water heated: connection pipes 1/2’’ female. 2 rows coil. ELECTRICAL HEATED Model RO 1000 E RO 1000 E-9 RO 1000 E230 RO 1500 E RO 1500 E230-6 RO 1500 E230-9 RO 2000 E RO 2000 E230 Airflow m3/h 1700 1700 1700 2200 2200 2200 3200 3200 Electrical Heating Capacity (*) kW 4/6 6/9 3,8/5,6 6/9 3,8/5,6 6/9 5,6/11,3 5,6/11,3 Electrical Heating Voltage V 400Vx3 400Vx3 230Vx1 400Vx3 230Vx1 230Vx1 400Vx3 230Vx1 Electrical Heating Current A 5,8/8,7 8,7/13 16,5/24,5 8,7/13 16,5/24,5 26/39,1 8,1/16,3 24,5/49,1 Noise Level (5 m) dB(A) 35/50 35/50 35/50 36/51 36/51 36/51 38/53 38/53 Weight kg 26 27 26 37,5 37,5 37,5 53,5 53,5 Recom. Height Up to m 2,8 2,8 2,8 2,8 2,8 2,8 2,8 2,8 Price euros 1.353 1.473 1.413 1.624 1.685 1.731 2.427 2.562 (*) Under request other electrical heating capacities may be supplied. Special Finishes Inlet and outlet grille painting according to RAL chart or metallic Accessories IR CONTROL CLEVER TD-NE IN-NE-II DC V-S/M V-T SPANG-SIL SPWR SLB SPCT 9 WINDBOX M,ECM,G,ECG | High Pressure Air Curtains For Commercial And Industrial Doors • Self-supporting casing construction made of galvanized steel plate, finished in structural epoxy-polyester painting white colour RAL9016 as standard. Other colours or stainless steel are available on request. • Micro-perforated inlet grille with filter functions and easy service. It does not need prefilter. • Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side. • Double-inlet centrifugal fans driven by an external rotor motor and low noise level. 5-speed selector. “EC” models assembled with very low consumption efficiency fans. • “P” type with water heated coil. “E” type with electrical shielded elements, three stages with integrated regulation. “A” type without heating, air only. Optional expansion DX coil. • Includes Plug&Play control with 7m RJ45 cable and infrared remote control. Optional: Clever control (programmable, automatic, intelligent, energy saving, Modbus RTU for BMS…). AIR ONLY Model M 1000 A M 1500 A M 2000 A M 2500 A M 3000 A ECM 1000 A ECM 1500 A ECM 2000 A ECM 2500 A ECM 3000 A G 1000 A G 1500 A G 2000 A G 2500 A G 3000 A ECG 1000 A ECG 1500 A ECG 2000 A ECG 2500 A ECG 3000 A Airflow m3/h 1800 2700 3600 4500 5400 1840 2760 3680 4600 5520 2400 3200 4800 5600 6400 2700 3600 5400 6300 7200 ELECTRICAL HEATED Model M 1000 E M 1500 E M 2000 E M 2500 E M 3000 E ECM 1000 E ECM 1500 E ECM 2000 E ECM 2500 E ECM 3000 E G 1000 E G 1500 E G 2000 E G 2500 E G 3000 E ECG 1000 E ECG 1500 E ECG 2000 E ECG 2500 E ECG 3000 E 10 Airflow m3/h 1800 2700 3600 4500 5400 1840 2760 3680 4600 5520 2400 3200 4800 5600 6400 2700 3600 5400 6300 7200 Power Fans 230Vx1 kW 0,212 0,318 0,424 0,530 0,636 0,132 0,198 0,264 0,330 0,396 0,642 0,856 1,284 1,498 1,712 0,225 0,300 0,450 0,525 0,600 Electrical Heating Capacity 400Vx3-50Hz kW 3/6/9 4/8/12 6/12/18 6/12/18 8/16/24 3/6/9 4/8/12 6/12/18 6/12/18 8/16/24 5/10/15 7,5/15/22,5 10/20/30 10/20/30 10/20/30 5/10/15 7,5/15/22,5 10/20/30 10/20/30 10/20/30 Current Fans 230Vx1 A 0,94 1,41 1,88 2,35 2,82 1,14 1,71 2,28 2,85 3,42 2,85 3,80 5,70 6,65 7,60 1,95 2,60 3,90 4,55 5,20 Power Fans 230Vx1 kW 0,212 0,318 0,424 0,530 0,636 0,132 0,198 0,264 0,330 0,396 0,642 0,856 1,284 1,498 1,712 0,225 0,300 0,450 0,525 0,600 Noise Level (5 m) dB(A) 55 56 57 58 59 56 57 58 59 60 57 58 59 60 61 61 62 63 64 65 Current Fans 230Vx1 A 0,94 1,41 1,88 2,35 2,82 1,14 1,71 2,28 2,85 3,42 2,85 3,80 5,70 6,65 7,60 1,95 2,60 3,90 4,55 5,20 Noise Level (5 m) dB(A) 55 56 57 58 59 56 57 58 59 60 57 58 59 60 61 61 62 63 64 65 Weight kg 31 46 58 72 86 31 46 58 72 86 43 51 80 84 95 43 51 80 84 95 Weight kg 37 57 75 94 112 37 57 75 94 112 52 63 100 106 120 52 63 100 106 120 Recommended Height Up to m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 4,2 Recommended Height Up to m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 4,2 Price euros 1.317 1.635 1.983 2.472 3.501 1.536 1.944 2.415 3.018 4.071 1.548 1.884 2.451 2.940 3.972 1.848 2.268 3.066 3.658 4.980 Price euros 2.148 2.556 3.015 3.807 5.328 2.358 2.865 3.447 4.359 5.934 2.415 2.868 3.828 4.728 5.943 2.703 3.235 4.440 5.448 6.918 WINDBOX M,ECM,G,ECG | WATER HEATED Model Airflow m3/h 1660 2490 3320 4150 4980 1720 2580 3440 4300 5160 2250 3000 4500 5250 6000 2550 3400 5100 5950 6800 M 1000 P M 1500 P M 2000 P M 2500 P M 3000 P ECM 1000 P ECM 1500 P ECM 2000 P ECM 2500 P ECM 3000 P G 1000 P G 1500 P G 2000 P G 2500 P G 3000 P ECG 1000 P ECG 1500 P ECG 2000 P ECG 2500 P ECG 3000 P P86 Heating Capacity 80/60ºC kW 9,17 14,26 20,65 26,92 33,24 9,38 14,58 21,12 27,53 40,00 11,04 16,02 24,92 31,16 37,35 11,89 17,29 26,86 33,63 40,34 P64 Heating Capacity 60/40ºC kW 8,56 13,69 18,26 22,12 28,37 8,77 14,02 18,70 23,33 29,05 10,42 15,47 22,29 26,61 32,10 11,27 16,77 24,14 28,84 34,81 High Pressure Air Curtains For Commercial And Industrial Doors P54 Heating Capacity 50/40ºC kW 8,52 14,34 18,65 24,32 29,77 8,74 14,71 19,13 24,95 30,54 10,56 16,37 23,15 28,76 34,03 11,50 17,86 25,24 31,38 37,16 Power Fans 230Vx1 kW 0,428 0,642 0,856 1,070 1,280 0,132 0,198 0,264 0,330 0,396 0,642 0,856 1,284 1,498 1,712 0,225 0,300 0,450 0,525 0,600 Current Fans 230Vx1 A 1,90 2,85 3,80 4,75 5,70 1,14 1,71 2,28 2,85 3,42 2,85 3,80 5,70 6,65 7,60 1,95 2,60 3,90 4,55 5,20 Noise Level (5 m) dB(A) 56 57 58 59 60 56 57 58 59 60 57 58 59 60 61 61 62 63 64 65 Weight kg 35 53 69 86 103 35 53 69 86 103 50 59 92 96 109 50 59 92 96 109 Recom. Height Up to m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 4,2 P86 Price euros 1.602 1.977 2.409 3.126 4.311 1.809 2.274 2.811 3.657 4.902 1.830 2.223 2.853 3.570 4.779 2.112 2.580 3.441 4.266 5.757 P64 Price euros 1.686 2.070 2.565 3.345 4.614 1.890 2.367 2.967 3.873 5.175 1.911 2.310 3.000 3.774 5.061 2.196 2.670 3.579 4.482 6.048 P54 Price euros 1.821 2.229 2.754 3.642 4.983 2.025 2.526 3.156 4.170 5.544 2.046 2.469 3.189 4.071 5.430 2.331 2.829 3.768 4.779 6.417 Water heated: connection pipes P86 and P64 are 2x3/4” female (male if lateral pipes), P54 2x1” male. P86 2 rows coil, P64 3 rows coil, P54 4 rows coil. Installation Options Telescopic outlet kit M, G euros 175 210 250 277 644 Model 1000 1500 2000 2500 3000 Telescopic inlet kit M, G euros 177 213 253 279 729 Telescopic false ceiling kit M, G euros 352 423 503 556 1.373 Telescopic false ceiling kit + plenum M, G euros 558 652 779 870 2.363 Plenum surface mounting M, G euros 206 229 276 314 990 Special Finishes Painting according RAL chart or metallic Stainless steel casing AISI 304 Accessories IR CONTROL CLEVER CH-5HW-NE TD-NE IN-NE-II DC V-S/M V-T AFS-INS SPWR SLB/SPCT SPF-MG SPJ2-MG 11 RECESSED WINDBOX | High Pressure Recessed Air Curtains For Commercial And Industrial Doors • Self-supporting casing construction made of galvanized steel plate, ready to be installed recessed in a false ceiling. • Inlet grille (free of maintenance) made with aluminium profiles and blow-out nozzle, integrated in a single white frame colour RAL 9016. Other colours are available on request. • Anodized aluminium outlet vanes, airfoil shaped, adjustable in both directions. • Double-inlet centrifugal fans driven by an external rotor motor and low noise level. 5-speed selector. “EC” models assembled with very low consumption efficiency fans. • “P” type with water heated coil. “E” type with electrical shielded elements, three stages with integrated regulation. “A” type without heating, air only. Optional expansion DX coil. • Includes Plug&Play control with 7m RJ45 cable and infrared remote control. Optional: Clever control (programmable, automatic, intelligent, energy saving, Modbus RTU for BMS…). AIR ONLY Model RM 1000 A RM 1500 A RM 2000 A RM 2500 A RECM 1000 A RECM 1500 A RECM 2000 A RECM 2500 A RG 1000 A RG 1500 A RG 2000 A RG 2500 A RECG 1000 A RECG 1500 A RECG 2000 A RECG 2500 A Airflow m3/h 1800 2700 3600 4500 1840 2760 3680 4600 2400 3200 4800 5600 2700 3600 5400 6300 ELECTRICAL HEATED Model RM 1000 E RM 1500 E RM 2000 E RM 2500 E RECM 1000 E RECM 1500 E RECM 2000 E RECM 2500 E RG 1000 E RG 1500 E RG 2000 E RG 2500 E RECG 1000 E RECG 1500 E RECG 2000 E RECG 2500 E 12 Airflow m3/h 1800 2700 3600 4500 1840 2760 3680 4600 2400 3200 4800 5600 2700 3600 5400 6300 Power Fans 230Vx1 kW 0,212 0,318 0,424 0,530 0,132 0,198 0,264 0,330 0,642 0,856 1,284 1,498 0,225 0,300 0,450 0,525 Electrical Heating Capacity 400Vx3-50Hz kW 3/6/9 4/8/12 6/12/18 6/12/18 3/6/9 4/8/12 6/12/18 6/12/18 5/10/15 7,5/15/22,5 10/20/30 10/20/30 5/10/15 7,5/15/22,5 10/20/30 10/20/30 Current Fans 230Vx1 A 0,94 1,41 1,88 2,35 1,14 1,71 2,28 2,85 2,85 3,80 5,70 6,65 1,95 2,60 3,90 4,55 Power Fans 230Vx1 kW 0,212 0,318 0,424 0,530 0,132 0,198 0,264 0,330 0,642 0,856 1,284 1,498 0,225 0,300 0,450 0,525 Noise Level (5 m) dB(A) 55 56 57 58 56 57 58 59 57 58 59 60 61 62 63 64 Current Fans 230Vx1 A 0,94 1,41 1,88 2,35 1,14 1,71 2,28 2,85 2,85 3,80 5,70 6,65 1,95 2,60 3,90 4,55 Noise Level (5 m) dB(A) 55 56 57 58 56 57 58 59 57 58 59 60 61 62 63 64 Weight kg 57 85 109 137 57 85 109 137 61 90 118 145 61 90 118 145 Weight kg 65 98 130 162 65 98 130 162 70 104 140 172 70 104 140 172 Recommended Height Up to m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 Recommended Height Up to m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 Price euros 1.998 2.394 2.817 3.288 2.205 2.721 3.183 3.750 2.235 2.643 3.288 3.753 2.575 3.103 4.008 4.584 Price euros 2.820 3.318 3.852 4.617 3.027 3.645 4.215 5.091 3.084 3.627 4.596 5.460 3.378 4.050 5.211 6.180 RECESSED WINDBOX | WATER HEATED Model RM 1000 P RM 1500 P RM 2000 P RM 2500 P RECM 1000 P RECM 1500 P RECM 2000 P RECM 2500 P RG 1000 P RG 1500 P RG 2000 P RG 2500 P RECG 1000 P RECG 1500 P RECG 2000 P RECG 2500 P Airflow m3/h 1660 2490 3320 4150 1720 2580 3440 4300 2250 3000 4500 5250 2550 3400 5100 5950 P86 Heating Capacity 80/60ºC kW 9,17 14,26 20,65 26,92 9,38 14,58 21,12 27,53 11,04 16,02 24,92 31,16 11,89 17,29 26,86 33,63 High Pressure Recessed Air Curtains For Commercial And Industrial Doors P64 Heating Capacity 60/40ºC kW 8,56 13,69 18,26 22,12 8,77 14,02 18,70 23,33 10,42 15,47 22,29 26,61 11,27 16,77 24,14 28,84 P54 Heating Capacity 50/40ºC kW 8,52 14,34 18,65 24,32 8,74 14,71 19,13 24,95 10,56 16,37 23,15 28,76 11,50 17,86 25,24 31,38 Power Fans 230Vx1 kW 0,428 0,642 0,856 1,070 0,132 0,198 0,264 0,330 0,642 0,856 1,284 1,498 0,225 0,300 0,450 0,525 Current Fans 230Vx1 A 1,90 2,85 3,80 4,75 1,14 1,71 2,28 2,85 2,85 3,80 5,70 6,65 1,95 2,60 3,90 4,55 Noise Level (5 m) dB(A) 56 57 58 59 56 57 58 59 57 58 59 60 61 62 63 64 Weight kg 63 93 122 153 63 93 122 153 67 98 131 163 67 98 131 163 Recom. Height Up to m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 P86 Price euros 2.283 2.757 3.219 3.915 2.478 3.051 3.579 4.389 2.517 2.982 3.690 4.383 2.845 3.424 4.380 5.037 P64 Price euros 2.361 2.850 3.366 4.119 2.562 3.144 3.735 4.605 2.598 3.069 3.834 4.584 2.922 3.501 4.516 5.367 P54 Price euros 2.496 3.009 3.555 4.416 2.697 3.303 3.924 4.902 2.733 3.228 4.023 4.881 3.057 3.660 4.705 5.664 SLB SPANG-SIL Water heated: connection pipes P86 and P64 are 2x3/4” female (male if lateral pipes), P54 2x1” male. P86 2 rows coil, P64 3 rows coil, P54 4 rows coil. Special Finishes Inlet and outlet grille painting according RAL chart or metallic Accessories IR CONTROL CLEVER CH-5HW-NE TD-NE IN-NE-II DC V-S/M V-T AFS-INS SPWR SPCT 13 SMART | Decorative High Pressure Air Curtains For Commercial And Industrial Doors • Stylish, discreet and contemporary design adaptive to any interior architecture. • Smooth front panel can be customized with logotypes, lighting, lettering or safety and informative signals, according to the client requirements. • Self-supporting steel rounded casing with edgeless plastic side covers, finished in structural epoxy-polyester painting white colour RAL9016 as standard. Other colours are available on request. • Hidden top air entrance, avoiding the inside view of the unit and the inlet grille. • Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side. • Double-inlet centrifugal fans driven by an external rotor motor and low noise level. 5-speed selector. “EC” models assembled with very low consumption efficiency fans. • Includes Plug&Play control with 7m RJ45 cable and infrared remote control. Optional: Clever control (programmable, automatic, intelligent, energy saving, Modbus RTU for BMS…). AIR ONLY Model SMART M 1000 A SMART M 1500 A SMART M 2000 A SMART M 2500 A SMART M 3000 A SMART ECM 1000 A SMART ECM 1500 A SMART ECM 2000 A SMART ECM 2500 A SMART ECM 3000 A SMART G 1000 A SMART G 1500 A SMART G 2000 A SMART G 2500 A SMART G 3000 A SMART ECG 1000 A SMART ECG 1500 A SMART ECG 2000 A SMART ECG 2500 A SMART ECG 3000 A Airflow m3/h 1800 2700 3600 4500 5400 1840 2760 3680 4600 5520 2400 3200 4800 5600 6400 2700 3600 5400 6300 7200 ELECTRICAL HEATED Model SMART M 1000 E SMART M 1500 E SMART M 2000 E SMART M 2500 E SMART M 3000 E SMART ECM 1000 E SMART ECM 1500 E SMART ECM 2000 E SMART ECM 2500 E SMART ECM 3000 E SMART G 1000 E SMART G 1500 E SMART G 2000 E SMART G 2500 E SMART G 3000 E SMART ECG 1000 E SMART ECG 1500 E SMART ECG 2000 E SMART ECG 2500 E SMART ECG 3000 E 14 Airflow m3/h 1800 2700 3600 4500 5400 1840 2760 3680 4600 5520 2400 3200 4800 5600 6400 2700 3600 5400 6300 7200 Power Fans 230Vx1 kW 0,212 0,318 0,424 0,530 0,636 0,132 0,198 0,264 0,330 0,396 0,642 0,856 1,284 1,498 1,712 0,225 0,300 0,450 0,525 0,600 Electrical Heating Capacity 400Vx3-50Hz kW 3/6/9 4/8/12 6/12/18 6/12/18 8/16/24 3/6/9 4/8/12 6/12/18 6/12/18 8/16/24 5/10/15 7,5/15/22,5 10/20/30 10/20/30 10/20/30 5/10/15 7,5/15/22,5 10/20/30 10/20/30 10/20/30 Current Fans 230Vx1 A 0,94 1,41 1,88 2,35 2,82 1,14 1,71 2,28 2,85 3,42 2,85 3,80 5,70 6,65 7,60 1,95 2,60 3,90 4,55 5,20 Power Fans 230Vx1 kW 0,212 0,318 0,424 0,530 0,636 0,132 0,198 0,264 0,330 0,396 0,642 0,856 1,284 1,498 1,712 0,225 0,300 0,450 0,525 0,600 Noise Level (5 m) dB(A) 53 54 55 56 57 54 55 56 57 58 55 56 57 58 59 59 60 61 62 63 Current Fans 230Vx1 A 0,94 1,41 1,88 2,35 2,82 1,14 1,71 2,28 2,85 3,42 2,85 3,80 5,70 6,65 7,60 1,95 2,60 3,90 4,55 5,20 Noise Level (5 m) dB(A) 53 54 55 56 57 54 55 56 57 58 55 56 57 58 59 59 60 61 62 63 Weight kg 34 50 62 66 76 34 50 62 66 76 38 55 72 76 86 38 55 72 76 86 Weight kg 41 62 80 86 99 41 62 80 86 99 46 68 90 96 109 46 68 90 96 109 Recommended Height Up to m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 4,2 Recommended Height Up to m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 4,2 Price euros 1.383 1.716 2.082 2.595 3.675 1.614 2.040 2.535 3.168 4.275 1.626 1.977 2.574 3.087 4.170 1.941 2.382 3.219 3.840 5.229 Price euros 2.256 2.685 3.165 3.996 5.595 2.475 3.009 3.618 4.578 6.231 2.535 3.012 4.020 4.965 6.240 2.838 3.396 4.662 5.721 7.263 SMART | Decorative High Pressure Air Curtains For Commercial And Industrial Doors WATER HEATED Model SMART M 1000 P SMART M 1500 P SMART M 2000 P SMART M 2500 P SMART M 3000 P SMART ECM 1000 P SMART ECM 1500 P SMART ECM 2000 P SMART ECM 2500 P SMART ECM 3000 P SMART G 1000 P SMART G 1500 P SMART G 2000 P SMART G 2500 P SMART G 3000 P SMART ECG 1000 P SMART ECG 1500 P SMART ECG 2000 P SMART ECG 2500 P SMART ECG 3000 P Airflow m3/h 1660 2490 3320 4150 4980 1720 2580 3440 4300 5160 2250 3000 4500 5250 6000 2550 3400 5100 5950 6800 P86 Heating Capacity 80/60ºC kW 9,17 14,26 20,65 26,92 33,24 9,38 14,58 21,12 27,53 40,00 11,04 16,02 24,92 31,16 37,35 11,89 17,29 26,86 33,63 40,34 P64 Heating Capacity 60/40ºC kW 8,56 13,69 18,26 22,12 28,37 8,77 14,02 18,70 23,33 29,05 10,42 15,47 22,29 26,61 32,10 11,27 16,77 24,14 28,84 34,81 P54 Heating Capacity 50/40ºC kW 8,52 14,34 18,65 24,32 29,77 8,74 14,71 19,13 24,95 30,54 10,56 16,37 23,15 28,76 34,03 11,50 17,86 25,24 31,38 37,16 Power Fans 230Vx1 kW 0,428 0,642 0,856 1,070 1,280 0,132 0,198 0,264 0,330 0,396 0,642 0,856 1,284 1,498 1,712 0,225 0,300 0,450 0,525 0,600 Current Fans 230Vx1 A 1,90 2,85 3,80 4,75 5,70 1,14 1,71 2,28 2,85 3,42 2,85 3,80 5,70 6,65 7,60 1,95 2,60 3,90 4,55 5,20 Noise Level (5 m) dB(A) 54 55 56 57 58 54 55 56 57 58 55 56 57 58 59 59 60 61 62 63 Weight kg 39 58 73 79 91 39 58 73 79 91 44 64 83 87 99 44 64 83 87 99 Recom. Height Up to m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 4,2 P86 Price euros 1.683 2.076 2.529 3.282 4.527 1.899 2.388 2.952 3.840 5.148 1.923 2.334 2.997 3.750 5.019 2.217 2.709 3.612 4.479 6.045 P64 Price euros 1.770 2.175 2.694 3.513 4.845 1.986 2.484 3.114 4.068 5.433 2.007 2.427 3.150 3.963 5.313 2.307 2.805 3.759 4.707 6.351 P54 Price euros 1.905 2.334 2.883 3.810 5.214 2.121 2.643 3.303 4.365 5.802 2.142 2.586 3.339 4.260 5.682 2.442 2.964 3.948 5.004 6.720 Water heated: connection pipes P86 and P64 are 2x3/4” female, P54 2x1” male. P86 2 rows coil, P64 3 rows coil, P54 4 rows coil. Smooth or customizable front panel with logos, lighting or signage Hidden top air entrance Special Finishes Stainless steel casing AISI 304 Painting according RAL chart or metallic Accessories IR CONTROL CLEVER CH-5HW-NE TD-NE IN-NE-II DC V-S/M V-T AFS-INS SPWR SLB/SPCT 15 ZEN | Decorative Air Curtains For Commercial Doors • Decorative air curtain in contemporary architectural style. Its minimalist and smart design integrates in any environment and offers infinite options to customize. • Can include personalized logotypes, signs or graphic designs. It can even incorporate clocks or lighting. • Front anodized aluminium panels. Optionally manufactured in brushed or mirror polished stainless steel. Other materials are possible, such as wood, metal, etc. • Central structure made of galvanized steel finished in black forge as standard. Other colours are available on request. • Anodized aluminium outlet vanes, airfoil shaped, adjustable in both directions. • Double-inlet centrifugal fans driven by an external rotor motor and low noise level. 5-speed selector. “EC” models assembled with very low consumption efficiency fans. • “P” type with water heated coil. “E” type with electrical shielded elements, three stages with integrated regulation. “A” type without heating, air only. Optional expansion DX coil. • Includes Plug&Play control with 7m RJ45 cable and infrared remote control. Optional: Clever control (programmable, automatic, intelligent, energy saving, Modbus RTU for BMS…). AIR ONLY Model ZEN M 1000 A ZEN M 1500 A ZEN M 2000 A ZEN M 2500 A ZEN G 1000 A ZEN G 1500 A ZEN G 2000 A ZEN G 2500 A ZEN ECG 1000 A ZEN ECG 1500 A ZEN ECG 2000 A ZEN ECG 2500 A Airflow m3/h 1980 2640 3960 4620 2400 3200 4800 5600 2700 3600 5400 6300 ELECTRICAL HEATED Model ZEN M 1000 E ZEN M 1500 E ZEN M 2000 E ZEN M 2500 E ZEN G 1000 E ZEN G 1500 E ZEN G 2000 E ZEN G 2500 E ZEN ECG 1000 E ZEN ECG 1500 E ZEN ECG 2000 E ZEN ECG 2500 E 16 Airflow m3/h 1980 2640 3960 4620 2400 3200 4800 5600 2700 3600 5400 6300 Power Fans 230Vx1 kW 0,318 0,424 0,636 0,742 0,642 0,856 1,284 1,498 0,225 0,300 0,450 0,525 Electrical Heating Capacity 400Vx3-50Hz kW 3/6/9 4/8/12 6/12/18 6/12/18 5/10/15 7,5/15/22,5 10/20/30 10/20/30 5/10/15 7,5/15/22,5 10/20/30 10/20/30 Current Fans 230Vx1 A 1,41 1,88 2,82 3,29 2,85 3,80 5,70 6,65 1,95 2,60 3,90 4,55 Power Fans 230Vx1 kW 0,318 0,424 0,636 0,742 0,642 0,856 1,284 1,498 0,225 0,300 0,450 0,525 Noise Level (5 m) dB(A) 55 56 57 58 57 58 59 60 61 62 63 64 Current Fans 230Vx1 A 1,41 1,88 2,82 3,29 2,85 3,80 5,70 6,65 1,95 2,60 3,90 4,55 Noise Level (5 m) dB(A) 55 56 57 58 57 58 59 60 61 62 63 64 Weight kg 32 46 62 75 36 50 69 83 36 50 69 83 Weight kg 40 58 77 94 43 62 85 103 43 62 85 103 Recommended Height Up to m 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 Recommended Height Up to m 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 Price euros 2.025 2.436 3.273 3.666 2.055 2.478 3.297 3.728 2.361 2.889 3.936 4.461 Price euros 2.865 3.378 4.326 5.025 3.001 3.577 4.719 5.660 3.234 3.876 5.352 6.282 ZEN | Decorative Air Curtains For Commercial Doors WATER HEATED Model ZEN M 1000 P ZEN M 1500 P ZEN M 2000 P ZEN M 2500 P ZEN G 1000 P ZEN G 1500 P ZEN G 2000 P ZEN G 2500 P ZEN ECG 1000 P ZEN ECG 1500 P ZEN ECG 2000 P ZEN ECG 2500 P Airflow m3/h 1860 2480 3720 4340 2250 3000 4500 5250 2550 3400 5100 5950 P86 Heating Capacity 80/60ºC kW 9,84 14,23 22,17 27,69 11,04 16,02 24,92 31,16 11,89 17,29 26,86 33,63 P64 Heating Capacity 60/40ºC kW 9,22 13,65 19,70 23,48 10,42 15,47 22,29 26,61 11,27 16,77 24,14 28,84 P54 Heating Capacity 50/40ºC kW 10,56 16,37 23,15 28,76 11,50 17,86 25,24 31,38 Power Fans 230Vx1 kW 0,318 0,424 0,636 0,742 0,642 0,856 1,284 1,498 0,225 0,300 0,450 0,525 Current Fans 230Vx1 A 1,41 1,88 2,82 3,29 2,85 3,80 5,70 6,65 1,95 2,60 3,90 4,55 Noise Level (5 m) dB(A) 55 56 57 58 57 58 59 60 61 62 63 64 Weight kg 37 53 71 86 40 57 78 95 40 57 78 95 Recom. Height Up to m 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 P86 Price euros 2.409 2.877 3.783 4.422 2.439 2.919 3.804 4.467 2.736 3.321 4.437 5.205 P64 Price euros 2.616 3.120 4.137 4.944 2.646 3.162 4.158 4.989 2.943 3.564 4.791 5.727 P54 Price euros 2.784 3.321 4.350 5.289 3.081 3.723 4.983 6.027 Water heated: connection pipes P86 and P64 are 2x3/4” female (male if lateral pipes), P54 2x1” male. P86 2 rows coil, P64 3 rows coil, P54 4 rows coil. Customizing and finishes Different materials, textures and colours standard / painted floral crocco / leather screen vintage wood logos / signage Examples of customized front panels Stainless steel AISI 304 brushed or polished Painting according RAL chart or metallic Accessories IR CONTROL CLEVER CH-5HW-NE TD-NE IN-NE-II DC V-S/M V-T AFS-INS SPWR SPCT SLB 17 RUND | Cylindrical Air Curtains • Decorative rounded air curtain for vertical or horizontal installation. • Faceted self-supporting casing construction made of galvanized plated steel, finished in structural epoxy-polyester painting white RAL9016 or silver grey RAL9006 as standard. Other colours or stainless steel are available on request. • Large perforated inlet grille avoiding intensive maintenance. • Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side. • Double-inlet centrifugal fans driven by an external rotor motor and low noise level. 5-speed selector. “EC” models assembled with very low consumption efficiency fans. • “P” type with water heated coil. “E” type with electrical shielded elements, three stages with integrated regulation. “A” type without heating, air only. Optional expansion DX coil. • Includes Plug&Play control with 7m RJ45 cable and infrared remote control. Optional: Clever control (programmable, automatic, intelligent, energy saving, Modbus RTU for BMS…). AIR ONLY Model RUND M 1000 A RUND M 1500 A RUND M 2000 A RUND M 2500 A RUND M 3000 A RUND G 1000 A RUND G 1500 A RUND G 2000 A RUND G 2500 A RUND G 3000 A RUND ECG 1000 A RUND ECG 1500 A RUND ECG 2000 A RUND ECG 2500 A RUND ECG 3000 A Airflow m3/h 1980 2640 3960 4620 5280 2400 3200 4800 5600 6400 2700 3600 5400 6300 7200 ELECTRICAL HEATED Model RUND M 1000 E RUND M 1500 E RUND M 2000 E RUND M 2500 E RUND M 3000 E RUND G 1000 E RUND G 1500 E RUND G 2000 E RUND G 2500 E RUND G 3000 E RUND ECG 1000 E RUND ECG 1500 E RUND ECG 2000 E RUND ECG 2500 E RUND ECG 3000 E 18 Airflow m3/h 1980 2640 3960 4620 5280 2400 3200 4800 5600 6400 2700 3600 5400 6300 7200 Power Fans 230Vx1 kW 0,318 0,424 0,636 0,742 0,848 0,642 0,856 1,284 1,498 1,712 0,225 0,300 0,450 0,525 0,600 Electrical Heating Capacity 400Vx3-50Hz kW 3/6/9 4/8/12 6/12/18 6/12/18 8/16/24 5/10/15 7,5/15/22,5 10/20/30 10/20/30 10/20/30 5/10/15 7,5/15/22,5 10/20/30 10/20/30 10/20/30 Current Fans 230Vx1 A 1,41 1,88 2,82 3,29 3,76 2,85 3,80 5,70 6,65 7,60 1,95 2,60 3,90 4,55 5,20 Power Fans 230V-50Hz kW 0,318 0,424 0,636 0,742 0,848 0,642 0,856 1,284 1,498 1,712 0,225 0,300 0,450 0,525 0,600 Noise Level (5 m) dB(A) 55 56 57 58 59 57 58 59 60 61 61 62 63 64 65 Current Fans 230V-50Hz A 1,41 1,88 2,82 3,29 3,76 2,85 3,80 5,70 6,65 7,60 1,95 2,60 3,90 4,55 5,20 Noise Level (5 m) dB(A) 55 56 57 58 59 57 58 59 60 61 61 62 63 64 65 Weight kg 42 63 79 88 99 46 68 89 98 108 46 68 89 98 108 Weight kg 49 75 97 108 119 54 81 107 118 128 54 81 107 118 128 Recommended Height Up to m 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 4,2 Recommended Height Up to m 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 4,2 Price euros 3.594 3.891 4.491 5.013 5.994 3.627 3.933 4.521 5.061 6.381 3.936 4.353 5.166 5.823 6.921 Price euros 4.446 4.845 5.559 6.390 7.896 4.518 4.944 5.961 6.915 8.358 4.821 5.355 6.606 7.671 8.970 RUND | Cylindrical Air Curtains WATER HEATED Model Airflow m3/h 1860 2480 3720 4340 4960 2250 3000 4500 5250 6000 2550 3400 5100 5950 6800 RUND M 1000 P RUND M 1500 P RUND M 2000 P RUND M 2500 P RUND M 3000 P RUND G 1000 P RUND G 1500 P RUND G 2000 P RUND G 2500 P RUND G 3000 P RUND ECG 1000 P RUND ECG 1500 P RUND ECG 2000 P RUND ECG 2500 P RUND ECG 3000 P P86 Heating Capacity 80/60ºC kW 9,84 14,23 22,17 27,69 33,15 11,04 16,02 24,92 31,16 37,35 11,89 17,29 26,86 33,63 40,34 P64 Heating Capacity 60/40ºC kW 9,22 13,65 19,70 23,48 28,29 10,42 15,47 22,29 26,61 32,10 11,27 16,77 24,14 28,84 34,81 P54 Heating Capacity 50/40ºC kW 10,56 16,37 23,15 28,76 34,03 11,50 17,86 25,24 31,38 37,16 Power Fans 230Vx1 kW 0,318 0,424 0,636 0,742 0,848 0,642 0,856 1,284 1,498 1,712 0,225 0,300 0,450 0,525 0,600 Current Fans 230Vx1 A 1,41 1,88 2,82 3,29 3,76 2,85 3,80 5,70 6,65 7,60 1,95 2,60 3,90 4,55 5,20 Noise Level (5 m) dB(A) 55 56 57 58 59 57 58 59 60 61 61 62 63 64 65 Weight kg 47 71 90 101 112 52 77 100 109 119 52 77 100 109 119 Recom. Height Up to m 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 4,2 P86 Price euros 3.894 4.248 4.917 5.691 6.870 3.951 4.317 5.064 5.805 7.149 4.227 4.701 5.583 6.492 7.788 P64 Price euros 4.104 4.494 5.277 6.222 7.551 4.155 4.551 5.406 6.306 7.695 4.437 4.947 5.943 7.023 8.469 P54 Price euros 4.293 4.710 5.598 6.606 8.070 4.575 5.106 6.135 7.323 8.844 Water heated: connection pipes P86 and P64 are 2x3/4” male (female if rear pipes), P54 2x1” male. P86 2 rows coil, P64 3 rows coil, P54 4 rows coil. Installation Options Wall anchored with lateral arms Wall/ceiling anchored with arms Wall/ceiling anchored with angle supports Vertical installation with foot Ceiling anchored with threaded rods Floor anchored (goalpost) Special Finishes Stainless steel AISI 304 Painting according RAL chart or metallic Accessories IR CONTROL CLEVER SPARM-180 CH-5HW-NE SPARM-90 TD-NE IN-NE-II DC V-S/M V-T AFS-INS SPWR SLB/SPCT SPF-RUND SPJ2-RUND SPANG-RUND SPANG-INT-RUND 19 DECO | Decorative Air Curtains For Commercial Doors • Structure made of aluminium profiles and galvanized plated steel panels, finished in structural epoxy-polyester white RAL 9016 or silver grey RAL 9006 as standard. Other colours are available on request. • Micro-perforated inlet grille with filter functions and easy service. It does not need prefilter. • Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side. • Double-inlet centrifugal fans driven by an external rotor motor and low noise level. 5-speed selector. “EC” models assembled with very low consumption efficiency fans. • “P” type with water heated coil. “E” type with electrical shielded elements, three stages with integrated regulation. “A” type without heating, air only. Optional expansion DX coil. • Includes Plug&Play control with 7m RJ45 cable and infrared remote control. Optional: Clever control (programmable, automatic, intelligent, energy saving, Modbus RTU for BMS…). AIR ONLY Model DM 1000 A DM 1500 A DM 2000 A DM 2500 A DECM 1000 A DECM 1500 A DECM 2000 A DECM 2500 A DG 1000 A DG 1500 A DG 2000 A DG 2500 A DECG 1000 A DECG 1500 A DECG 2000 A DECG 2500 A Airflow m3/h 1800 2700 3600 4500 1840 2760 3680 4600 2400 3200 4800 5600 2700 3600 5400 6300 Power Fans 230V-50Hz kW 0,212 0,318 0,424 0,530 0,132 0,198 0,264 0,330 0,642 0,856 1,284 1,498 0,225 0,300 0,450 0,525 Airflow m3/h 1800 2700 3600 4500 1840 2760 3680 4600 2400 3200 4800 5600 2700 3600 5400 6300 Electrical Heating Capacity 400Vx3-50Hz kW 3/6/9 4/8/12 6/12/18 6/12/18 3/6/9 4/8/12 6/12/18 6/12/18 5/10/15 7,5/15/22,5 10/20/30 10/20/30 5/10/15 7,5/15/22,5 10/20/30 10/20/30 ELECTRICAL HEATED Model DM 1000 E DM 1500 E DM 2000 E DM 2500 E DECM 1000 E DECM 1500 E DECM 2000 E DECM 2500 E DG 1000 E DG 1500 E DG 2000 E DG 2500 E DECG 1000 E DECG 1500 E DECG 2000 E DECG 2500 E 20 Current Fans 230V-50Hz A 0,94 1,41 1,88 2,35 1,14 1,71 2,28 2,85 2,85 3,80 5,70 6,65 1,95 2,60 3,90 4,55 Power Fans 230V-50Hz kW 0,212 0,318 0,424 0,530 0,132 0,198 0,264 0,330 0,642 0,856 1,284 1,498 0,225 0,300 0,450 0,525 Noise Level (5 m) dB(A) 55 56 57 58 56 57 58 59 57 58 59 60 61 62 63 64 Current Fans 230V-50Hz A 0,94 1,41 1,88 2,35 1,14 1,71 2,28 2,85 2,85 3,80 5,70 6,65 1,95 2,60 3,90 4,55 Noise Level (5 m) dB(A) 55 56 57 58 56 57 58 59 57 58 59 60 61 62 63 64 Weight kg 51 75 96 108 51 75 96 108 55 80 106 118 55 80 106 118 Weight kg 58 87 114 128 58 87 114 128 63 93 124 138 63 93 124 138 Recommended Height Up to m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 Recommended Height Up to m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 Price euros 2.028 2.469 2.919 3.528 2.247 2.778 3.351 4.029 2.259 2.718 3.387 3.993 2.559 3.102 4.002 4.668 Price euros 2.859 3.435 3.996 5.115 3.069 3.699 4.383 5.370 3.127 3.763 4.817 5.957 3.414 4.068 5.376 6.459 DECO | Decorative Air Curtains For Commercial Doors WATER HEATED Model DM 1000 P DM 1500 P DM 2000 P DM 2500 P DECM 1000 P DECM 1500 P DECM 2000 P DECM 2500 P DG 1000 P DG 1500 P DG 2000 P DG 2500 P DECG 1000 P DECG 1500 P DECG 2000 P DECG 2500 P Airflow m3/h 1660 2490 3320 4150 1720 2580 3440 4300 2250 3000 4500 5250 2550 3400 5100 5950 P86 Heating Capacity 80/60ºC kW 9,17 14,26 20,65 26,92 9,38 14,58 21,12 27,53 11,04 16,02 24,92 31,16 11,89 17,29 26,86 33,63 P64 Heating Capacity 60/40ºC kW 8,56 13,69 18,26 22,12 8,77 14,02 18,70 23,33 10,42 15,47 22,29 26,61 11,27 16,77 24,14 28,84 P54 Heating Capacity 50/40ºC kW 8,52 14,34 18,65 24,32 8,74 14,71 19,13 24,95 10,56 16,37 23,15 28,76 11,50 17,86 25,24 31,38 Power Fans 230Vx1 kW 0,428 0,642 0,856 1,070 0,132 0,198 0,264 0,330 0,642 0,856 1,284 1,498 0,225 0,300 0,450 0,525 Current Fans 230Vx1 A 1,90 2,85 3,80 4,75 1,14 1,71 2,28 2,85 2,85 3,80 5,70 6,65 1,95 2,60 3,90 4,55 Noise Level (5 m) dB(A) 56 57 58 59 56 57 58 59 57 58 59 60 61 62 63 64 Weight kg 56 83 107 121 56 83 107 121 61 89 117 129 61 89 117 129 Recom. Height Up to m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 P86 Price euros 2.322 2.859 3.345 4.248 2.520 3.108 3.747 4.668 2.559 3.057 3.798 4.713 2.823 3.414 4.377 5.277 P64 Price euros 2.400 2.946 3.501 4.449 2.601 3.201 3.903 4.884 2.637 3.192 3.948 4.914 2.907 3.504 4.515 5.493 SPCT SLB P54 Price euros 2.535 3.105 3.690 4.746 2.736 3.360 4.092 5.181 2.772 3.351 4.137 5.211 3.042 3.663 4.704 5.790 Water heated: connection pipes P86 and P64 are 2x3/4” female, P54 2x1” male. P86 2 rows coil, P64 3 rows coil, P54 4 rows coil. Installation Options Joining 2 units Adjustable fixing points through guide rails Special Finishes Painting according RAL chart or metallic Accessories IR CONTROL CLEVER CH-5HW-NE TD-NE IN-NE-II DC V-S/M V-T AFS-INS SPWR 21 DAM | High Pressure Air Curtains For Commercial And Industrial Doors • Self-supporting casing construction made of galvanized steel plate, finished in structural epoxy-polyester painting white colour RAL9016 as standard. Other colours or stainless steel are available on request. • Front panel with option to customize and the possibility of including personalized logos, signs, graphic designs, images, etc. • The inlet areas are located behind the front panel. They do not need maintenance. • Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side. • Double-inlet centrifugal fans driven by an external rotor motor and low noise level. 5-speed selector. “EC” models assembled with very low consumption efficiency fans. • “P” type with water heated coil. “E” type with electrical shielded elements, three stages with integrated regulation. “A” type without heating, air only. Optional expansion DX coil. • Includes Plug&Play control with 7m RJ45 cable and infrared remote control. Optional: Clever control (programmable, automatic, intelligent, energy saving, Modbus RTU for BMS…). AIR ONLY Model DAM M 1000 A DAM M 1500 A DAM M 2000 A DAM M 2500 A DAM M 3000 A DAM ECM 1000 A DAM ECM 1500 A DAM ECM 2000 A DAM ECM 2500 A DAM ECM 3000 A DAM G 1000 A DAM G 1500 A DAM G 2000 A DAM G 2500 A DAM G 3000 A DAM ECG 1000 A DAM ECG 1500 A DAM ECG 2000 A DAM ECG 2500 A DAM ECG 3000 A Airflow m3/h 1800 2700 3600 4500 5400 1840 2760 3680 4600 5520 2400 3200 4800 5600 6400 2700 3600 5400 6300 7200 Power Fans 230V-50Hz kW 0,212 0,318 0,424 0,530 0,636 0,132 0,198 0,264 0,330 0,396 0,642 0,856 1,284 1,498 1,712 0,225 0,300 0,450 0,525 0,600 Airflow m3/h 1800 2700 3600 4500 5400 1840 2760 3680 4600 5520 2400 3200 4800 5600 6400 2700 3600 5400 6300 7200 Electrical Heating Capacity 400Vx3-50Hz kW 3/6/9 4/8/12 6/12/18 6/12/18 8/16/24 3/6/9 4/8/12 6/12/18 6/12/18 8/16/24 5/10/15 7,5/15/22,5 10/20/30 10/20/30 10/20/30 5/10/15 7,5/15/22,5 10/20/30 10/20/30 10/20/30 ELECTRICAL HEATED Model DAM M 1000 E DAM M 1500 E DAM M 2000 E DAM M 2500 E DAM M 3000 E DAM ECM 1000 E DAM ECM 1500 E DAM ECM 2000 E DAM ECM 2500 E DAM ECM 3000 E DAM G 1000 E DAM G 1500 E DAM G 2000 E DAM G 2500 E DAM G 3000 E DAM ECG 1000 E DAM ECG 1500 E DAM ECG 2000 E DAM ECG 2500 E DAM ECG 3000 E 22 Current Fans 230V-50Hz A 0,94 1,41 1,88 2,35 2,82 1,14 1,71 2,28 2,85 3,42 2,85 3,80 5,70 6,65 7,60 1,95 2,60 3,90 4,55 5,20 Power Fans 230V-50Hz kW 0,212 0,318 0,424 0,530 0,636 0,132 0,198 0,264 0,330 0,396 0,642 0,856 1,284 1,498 1,712 0,225 0,300 0,450 0,525 0,600 Noise Level (5 m) dB(A) 53 54 55 56 57 54 55 56 57 58 55 56 57 58 59 59 60 61 62 63 Current Fans 230V-50Hz A 0,94 1,41 1,88 2,35 2,82 1,14 1,71 2,28 2,85 3,42 2,85 3,80 5,70 6,65 7,60 1,95 2,60 3,90 4,55 5,20 Noise Level (5 m) dB(A) 55 56 57 58 59 56 57 58 59 60 57 58 59 60 61 61 62 63 64 65 Weight kg 38 56 70 76 88 38 56 70 76 88 42 61 80 86 98 42 61 80 86 98 Weight kg 45 68 88 96 111 45 68 88 96 111 50 74 98 106 121 50 74 98 106 121 Recommended Height Up to m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 4,2 Recommended Height Up to m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 4,2 Price euros 1.455 1.872 2.310 2.745 3.801 1.674 2.205 2.760 3.243 4.476 1.686 2.157 2.751 3.213 4.272 1.980 2.556 3.372 3.852 5.079 Price euros 2.286 2.799 3.348 4.071 5.667 2.496 3.126 3.795 4.584 6.339 2.553 3.141 4.173 4.953 6.258 2.841 3.531 4.788 5.676 7.098 DAM | High Pressure Air Curtains For Commercial And Industrial Doors WATER HEATED Model DAM M 1000 P DAM M 1500 P DAM M 2000 P DAM M 2500 P DAM M 3000 P DAM ECM 1000 P DAM ECM 1500 P DAM ECM 2000 P DAM ECM 2500 P DAM ECM 3000 P DAM G 1000 P DAM G 1500 P DAM G 2000 P DAM G 2500 P DAM G 3000 P DAM ECG 1000 P DAM ECG 1500 P DAM ECG 2000 P DAM ECG 2500 P DAM ECG 3000 P Airflow m3/h 1660 2490 3320 4150 4980 1720 2580 3440 4300 5160 2250 3000 4500 5250 6000 2550 3400 5100 5950 6800 P86 Heating Capacity 80/60ºC kW 9,17 14,26 20,65 26,92 33,24 9,38 14,58 21,12 27,53 40,00 11,04 16,02 24,92 31,16 37,35 11,89 17,29 26,86 33,63 40,34 P64 Heating Capacity 60/40ºC kW 8,56 13,69 18,26 22,12 28,37 8,77 14,02 18,70 23,33 29,05 10,42 15,47 22,29 26,61 32,10 11,27 16,77 24,14 28,84 34,81 P54 Heating Capacity 50/40ºC kW 8,52 14,34 18,65 24,32 29,77 8,74 14,71 19,13 24,95 30,54 10,56 16,37 23,15 28,76 34,03 11,50 17,86 25,24 31,38 37,16 Power Fans 230Vx1 kW 0,428 0,642 0,856 1,070 1,280 0,132 0,198 0,264 0,330 0,396 0,642 0,856 1,284 1,498 1,712 0,225 0,300 0,450 0,525 0,600 Current Fans 230Vx1 A 1,90 2,85 3,80 4,75 5,70 1,14 1,71 2,28 2,85 3,42 2,85 3,80 5,70 6,65 7,60 1,95 2,60 3,90 4,55 5,20 Noise Level (5 m) dB(A) 56 57 58 59 60 56 57 58 59 60 57 58 59 60 61 61 62 63 64 65 Weight kg 43 64 81 89 103 43 64 81 89 103 48 70 91 97 111 48 70 91 97 111 Recom. Height Up to m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 4,2 P86 Price euros 1.740 2.238 2.757 3.372 4.656 1.947 2.535 3.159 3.882 5.307 1.968 2.496 3.156 3.840 5.079 2.250 2.886 3.768 4.491 5.910 P64 Price euros 1.824 2.331 2.913 3.576 4.932 2.031 2.628 3.315 4.098 5.580 2.049 2.589 3.312 4.044 5.343 2.334 2.979 3.924 4.707 6.183 P54 Price euros 1.959 2.490 3.102 3.873 5.301 2.166 2.787 3.504 4.395 5.949 2.184 2.748 3.501 4.341 5.712 2.469 3.138 4.113 5.004 6.552 Water heated: connection pipes P86 and P64 are 2x3/4” female (male if lateral pipes), P54 2x1” male. P86 2 rows coil, P64 3 rows coil, P54 4 rows coil. Customizing Smooth or customizable front panel with logos, lighting or signage Special Finishes Stainless steel casing AISI 304 Painting according RAL chart or metallic Accessories IR CONTROL CLEVER CH-5HW-NE TD-NE IN-NE-II DC V-S/M V-T AFS-INS SPWR SLB/SPCT SPF-MG SPJ2-MG 23 RECESSED DAM | Compact Recessed High Pressure Air Curtains For Commercial And Industrial Doors • Compact and low profile recessed air curtain with full grille view. • Self-supporting casing construction made of galvanized steel plate, ready to be installed recessed in a false ceiling. • Inlet grille (free of maintenance) made with aluminium profiles and blow-out nozzle, integrated in a single white frame colour RAL 9016. Other colours are available on request. • Double-inlet centrifugal fans driven by an external rotor motor and low noise level. 5-speed selector. “EC” models assembled with very low consumption efficiency fans. • “P” type with water heated coil. “E” type with electrical shielded elements, three stages with integrated regulation. “A” type without heating, air only. Optional expansion DX coil. • Includes Plug&Play control with 7m RJ45 cable and infrared remote control. Optional: Clever control (programmable, automatic, intelligent, energy saving, Modbus RTU for BMS…). AIR ONLY Model RDAM M 1000 A RDAM M 1500 A RDAM M 2000 A RDAM M 2500 A RDAM ECM 1000 A RDAM ECM 1000 A RDAM ECM 2000 A RDAM ECM 2500 A RDAM G 1000 A RDAM G 1500 A RDAM G 2000 A RDAM G 2500 A RDAM ECG 1000 A RDAM ECG 1500 A RDAM ECG 2000 A RDAM ECG 2500 A Airflow m3/h 1800 2700 3600 4500 1840 2760 3680 4600 2400 3200 4800 5600 2700 3600 5400 6300 Power Fans 230V-50Hz kW 0,212 0,318 0,424 0,530 0,132 0,198 0,264 0,330 0,642 0,856 1,284 1,498 0,225 0,300 0,450 0,525 Airflow m3/h 1800 2700 3600 4500 1840 2760 3680 4600 2400 3200 4800 5600 2700 3600 5400 6300 Electrical Heating Capacity 400Vx3-50Hz kW 3/6/9 4/8/12 6/12/18 6/12/18 3/6/9 4/8/12 6/12/18 6/12/18 5/10/15 7,5/15/22,5 10/20/30 10/20/30 5/10/15 7,5/15/22,5 10/20/30 10/20/30 ELECTRICAL HEATED Model RDAM M 1000 E RDAM M 1500 E RDAM M 2000 E RDAM M 2500 E RDAM ECM 1000 E RDAM ECM 1500 E RDAM ECM 2000 E RDAM ECM 2500 E RDAM G 1000 E RDAM G 1500 E RDAM G 2000 E RDAM G 2500 E RDAM ECG 1000 E RDAM ECG 1500 E RDAM ECG 2000 E RDAM ECG 2500 E 24 Current Fans 230V-50Hz A 0,94 1,41 1,88 2,35 1,14 1,71 2,28 2,85 2,85 3,80 5,70 6,65 1,95 2,60 3,90 4,55 Power Fans 230V-50Hz kW 0,212 0,318 0,424 0,530 0,132 0,198 0,264 0,330 0,642 0,856 1,284 1,498 0,225 0,300 0,450 0,525 Noise Level (5 m) dB(A) 55 56 57 58 56 57 58 59 57 58 59 60 61 62 63 64 Current Fans 230V-50Hz A 0,94 1,41 1,88 2,35 1,14 1,71 2,28 2,85 2,85 3,80 5,70 6,65 1,95 2,60 3,90 4,55 Noise Level (5 m) dB(A) 55 56 57 58 56 57 58 59 57 58 59 60 61 62 63 64 Weight kg 45 66 84 93 45 66 84 93 49 71 94 103 49 71 94 103 Weight kg 52 78 102 113 52 78 102 113 57 84 112 123 57 84 112 123 Recommended Height Up to m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 Recommended Height Up to m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 Price euros 1.956 2.478 3.006 3.444 2.175 2.811 3.459 4.002 2.187 2.724 3.447 3.885 2.481 3.120 4.068 4.611 Price euros 2.832 3.453 4.092 4.836 3.042 3.780 4.536 5.385 3.099 3.750 4.917 5.757 3.387 4.140 5.532 6.477 RECESSED DAM | WATER HEATED Model RDAM M 1000 P RDAM M 1500 P RDAM M 2000 P RDAM M 2500 P RDAM ECM 1000 P RDAM ECM 1500 P RDAM ECM 2000 P RDAM ECM 2500 P RDAM G 1000 P RDAM G 1500 P RDAM G 2000 P RDAM G 2500 P RDAM ECG 1000 P RDAM ECG 1500 P RDAM ECG 2000 P RDAM ECG 2500 P Airflow m3/h 1660 2490 3320 4150 1720 2580 3440 4300 2250 3000 4500 5250 2550 3400 5100 5950 Compact Recessed High Pressure Air Curtains For Commercial And Industrial Doors P86 Heating Capacity 80/60ºC kW 9,17 14,26 20,65 26,92 9,38 14,58 21,12 27,53 11,04 16,02 24,92 31,16 11,89 17,29 26,86 33,63 P64 Heating Capacity 60/40ºC kW 8,56 13,69 18,26 22,12 8,77 14,02 18,70 23,33 10,42 15,47 22,29 26,61 11,27 16,77 24,14 28,84 P54 Heating Capacity 50/40ºC kW 8,52 14,34 18,65 24,32 8,74 14,71 19,13 24,95 10,56 16,37 23,15 28,76 11,50 17,86 25,24 31,38 Power Fans 230Vx1 kW 0,428 0,642 0,856 1,070 0,132 0,198 0,264 0,330 0,642 0,856 1,284 1,498 0,225 0,300 0,450 0,525 Current Fans 230Vx1 A 1,90 2,85 3,80 4,75 1,14 1,71 2,28 2,85 2,85 3,80 5,70 6,65 1,95 2,60 3,90 4,55 Noise Level (5 m) dB(A) 56 57 58 59 56 57 58 59 57 58 59 60 61 62 63 64 Weight kg 50 74 95 106 50 74 95 106 55 80 105 114 55 80 105 114 Recom. Height Up to m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 P86 Price euros 2.241 2.847 3.453 4.110 2.448 3.141 3.855 4.638 2.469 3.063 3.852 4.530 2.751 3.450 4.464 5.250 P64 Price euros 2.325 2.940 3.612 4.326 2.532 3.234 4.011 4.857 2.550 3.156 4.011 4.749 2.835 3.543 4.623 5.466 P54 Price euros 2.460 3.099 3.801 4.623 2.667 3.393 4.200 5.154 2.685 3.315 4.200 5.046 2.970 3.702 4.812 5.763 SLB SPANG-SIL Water heated: connection pipes P86 and P64 are 2x3/4” female (male if lateral pipes), P54 2x1” male. P86 2 rows coil, P64 3 rows coil, P54 4 rows coil. Special Finishes Inlet and outlet grille painting according RAL chart or metallic Accessories IR CONTROL CLEVER CH-5HW-NE TD-NE IN-NE-II DC V-S/M V-T AFS-INS SPWR SPCT 25 HEAT PUMP AIR CURTAINS | Heating and Cooling Low Consumption Air Curtains Heat Pump Technology Heat pump is a device that uses a small amount of energy to move heat from one location to another. This system is extremely efficient because it simply transfers heat, rather than burn fuel to create it. It consists of a closed circuit through which a special fluid (refrigerant) flows. This fluid takes on a liquid or gaseous state according to temperature and pressure conditions. The circuit is composed by: compressor, condenser, expansion valve and evaporator. Advantages and Benefits The new Airtecnics Heat Pump Air curtains are absolutely efficient reducing the heating cost and CO2 emissions up to 70%. • Very high energy efficiency ratings to save big amounts of money on your energy bill • Short Payback Period thanks to very high level of energy saving • Heating and cooling included in the same system (reverse cycle) • Environmentally Friendly as uses such low amounts of energy Available Airtecnics Heat Pump Air Curtains: • Heating/Cooling: Windbox M-ECM-G-ECG, Dam, Recessed Windbox, Smart, Recessed Dam, Variwind VW and Windbox L-XL. • Only Heating: Deco, Rund, Zen, Rotowind, Variwind VP and Invisair. Heat Pump vs Electrical Air Curtain - Energy Saving Example How much money can I save using a Heat Pump Air curtain? Example: Door dimension: 2 m width by 3 m height Running time: 12 hours/day, 6 days/week, 26 weeks (~ 1/2 year) Energy cost: 0,17 €/kW/h (EU-27 average cost) Selected unit: G 2000, 27kW COP: 3,31 (Coefficient of Performance) Electrical Air Curtain Total Heating Power 27 kW Air Curtain Price 3.828 Energy Consumption 50.544 Heat Pump Air Curtain Difference 27 kW 0 kW €/unit 10.987 €/unit + 7.159 € kW/h 15.270 kW/h - 35.274 kW/h Energy Cost 8.592 € 2.596 € - 5.996 € CO2 Emissions 20.218 kg 6.108 kg - 14.110 kg Result: The payback periode is 1,2 years. We recover the price increase of Heat Pump air curtain in nearly 14 months and then we start saving money. From the beginning we save energy and reduce CO2 emissions to the enviroment. € € 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 0 100000 80000 Electrical Heated 70000 60000 50000 40000 30000 Heat Pump 0 100000 60000 CO2 Electrical Heated 80000 Savings 40000 1 2 3 4 5 6 7 8 9 10 Years 10 Years Energy Cost 25000 Electrical Heated 20000 10000 Savings Heat Pump 5000 1 2 3 4 5 6 7 8 9 10 Payback Periode 26 Heat Pump 15000 Heat Pump 20000 0 Savings 20000 10000 1 Year Energy Cost € Electrical Heated Years 0 1 2 3 4 5 6 7 8 9 10 10 Years CO2 Emisions Years WINDBOX M,ECM,G,ECG DX | Heat Pump Energy Saving Air Curtains For TOSHIBA Outdoor Units • Energy saving heat pump air curtains: Up to 70% reduction in costs and CO2 emissions (heating mode). • Self-supporting casing construction made of galvanized steel plate, finished in structural epoxy-polyester painting white colour RAL9016 as standard. Other colours or stainless steel are available on request. • Micro-perforated inlet grille with filter functions and easy service. Internal prefilter included. • Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side. • Double-inlet centrifugal fans driven by an external rotor motor and low noise level. 5-speed selector. “EC” models assembled with very low consumption efficiency fans. • Includes direct expansion coil with sensors. Optional condensate water pump. • Plug&Play control panel, infrared remote IR and 7m telephone cable included. • TOSHIBA DX Interface KIT and programmable control included. • Ready to connect to TOSHIBA Digital Inverter outdoor heat pump unit (R410A) with expansion valve. Model (*) Airflow Outdoor unit Power Supply M 1500 DX11-TO M 2000 DX16-TO M 2500 DX22-TO M 3000 DX27-TO ECM 1000 DX8-TO ECM 1500 DX11-TO ECM 2000 DX16-TO ECM 2500 DX22-TO ECM 3000 DX27-TO G 1000 DX11-TO G 1500 DX16-TO G 2000 DX22-TO G 2000 DX27-TO G 2500 DX27-TO G 3000 DX27-TO G 3000 DX32/2-TO ECG 1000 DX11-TO ECG 1500 DX16-TO ECG 2000 DX22-TO ECG 2000 DX27-TO ECG 2500 DX27-TO ECG 3000 DX27-TO ECG 3000 DX32/2-TO m3/h 2160 2880 3600 4320 1640 2460 3280 4100 4920 2100 2800 4200 4200 4900 5600 5600 2190 2920 4380 4380 5110 5840 5840 230Vx1 RAV-SM1104ATP-E RAV-SM1603AT-E RAV-SM804ATP-E RAV-SM1104ATP-E RAV-SM1603AT-E RAV-SM1104ATP-E RAV-SM1603AT-E 2x RAV-SM1603AT-E RAV-SM1104ATP-E RAV-SM1603AT-E 2x RAV-SM1603AT-E Outdoor unit Power Supply Power Fans 230V-50Hz Current Fans 230V-50Hz Noise Level (5 m) 400Vx3 (**) RAV-SP1104AT8-E RAV-SP1604AT8-E RAV-SM2244AT8-E RAV-SM2804AT8-E RAV-SP1104AT8-E RAV-SP1604AT8-E RAV-SM2244AT8-E RAV-SM2804AT8-E RAV-SP1104AT8-E RAV-SP1604AT8-E RAV-SM2244AT8-E RAV-SM2804AT8-E RAV-SM2804AT8-E RAV-SM2804AT8-E 2x RAV-SP1604AT8-E RAV-SP1104AT8-E RAV-SP1604AT8-E RAV-SM2244AT8-E RAV-SM2804AT8-E RAV-SM2804AT8-E RAV-SM2804AT8-E 2x RAV-SP1604AT8-E kW 0,642 0,856 1,070 1,280 0,132 0,198 0,264 0,330 0,396 0,642 0,856 1,284 1,284 1,498 1,712 1,712 0,225 0,300 0,450 0,450 0,525 0,600 0,600 A 2,85 3,80 4,75 5,70 1,14 1,71 2,28 2,85 3,42 2,85 3,80 5,70 5,70 6,65 7,60 7,60 1,95 2,60 3,90 3,90 4,55 5,20 5,20 dB(A) 57 58 59 60 56 57 58 59 60 57 58 59 59 60 61 61 61 62 63 63 64 65 65 Weight Recom. Height Up to Price kg 53 69 86 103 35 53 69 86 103 50 59 92 92 96 99 109 50 59 92 92 96 109 109 m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 4,2 4,2 4,2 euros consult consult consult consult consult consult consult consult consult consult consult consult consult consult consult consult consult consult consult consult consult consult consult (*) DX is also applicable to the models: Recessed Windbox, Smart, Dam, Recessed Dam, Deco, Variwind, Rund, Zen, Rotowind, Invisair. 33/2 Coil with double circuit and two outdoor units of 16kW. (**) Air curtains supply is always 230Vx1. TOSHIBA Digital Inverter Outdoor Units RAV-SM804ATP-E RAV-SM1104ATP-E RAV-SP1104AT8-E RAV-SM1603AT-E RAV-SP1604AT8-E RAV-SM2244AT8-E RAV-SM2804AT8-E Heating Capacity Heating Power SCOP or COP (*) Cooling Capacity Cooling Power SEER or EER (*) Power Supply Pipes Gas Liquid Pipes Minimum Lenght Pipes Maximum Lenght Pipes Maximum Height kW 8,0 11,2 11,2 16,0 16,0 22,4 27,0 kW 2,21 2,93 2,42 4,43 4,30 6,49 8,15 W/W 4,02 3,54 4,28 3,61 3,72 3,45 3,31 kW 6,7 10,0 10,0 14,0 14,0 20,0 23,0 kW 2,09 3,11 2,37 4,49 4,49 7,20 8,75 W/W 5,63 5,58 6,57 3,12 3,12 2,78 2,63 230Vx1 230Vx1 400Vx3 230Vx1 400Vx3 400Vx3 400Vx3 inch 5/8 3/8 5/8 3/8 5/8 3/8 5/8 3/8 5/8 3/8 1”1/8 1/2” 1”1/8 1/2” m 5 5 3 5 3 7,5 7,5 m 30 50 75 50 75 70 70 m 30 30 30 30 30 30 30 (*) Energy efficiency: SCOP and SEER seasonal ratio under 12kW and COP and EER over 12kW. 27 WINDBOX M,ECM,G,ECG DX | Heat Pump Energy Saving Air Curtains For MITSUBISHI ELECTRIC Outdoor Units • Energy saving heat pump air curtains: Up to 70% reduction in costs and CO2 emissions (heating mode). • Self-supporting casing construction made of galvanized steel plate, finished in structural epoxy-polyester painting white colour RAL9016 as standard. Other colours or stainless steel are available on request. • Micro-perforated inlet grille with filter functions and easy service. Internal prefilter included. • Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side. • Double-inlet centrifugal fans driven by an external rotor motor and low noise level. 5-speed selector. “EC” models assembled with very low consumption efficiency fans. • Includes direct expansion coil with sensors. Optional condensate water pump. • Plug&Play control panel, infrared remote IR and 7m telephone cable included. • MITSUBISHI ELECTRIC DX Interface KIT and programmable control included. • Ready to connect to MITSUBISHI ELECTRICAL Digital Inverter outdoor heat pump unit (R410A) with expansion valve. Model (*) Airflow Outdoor unit Power Supply M 1500 DX11-ME M 2000 DX14-ME M 2000 DX16-ME M 2500 DX22-ME M 3000 DX27-ME ECM 1000 DX8-ME ECM 1500 DX11-ME ECM 1500 DX14-ME ECM 2000 DX16-ME ECM 2500 DX22-ME ECM 3000 DX27-ME G 1000 DX8-ME G 1500 DX14-ME G 2000 DX22-ME G 2500 DX27-ME G 3000 DX27-ME G 3000 DX32/2-ME ECG 1000 DX8-ME ECG 1500 DX16-ME ECG 2000 DX22-ME ECG 2500 DX27-ME ECG 3000 DX27-ME ECG 3000 DX32/2-ME m3/h 2160 2880 2880 3600 4320 1640 2460 2460 3280 4100 4920 2100 2800 4200 4900 5600 5600 2190 2920 4380 5110 5840 5840 230Vx1 PUHZ-ZRP100VKA PUHZ-ZRP125VKA PUHZ-ZRP140VKA PUHZ-ZRP71VHA PUHZ-ZRP100VKA PUHZ-ZRP125VKA PUHZ-ZRP140VKA PUHZ-ZRP71VHA PUHZ-ZRP125VKA 2x PUHZ-ZRP140VKA PUHZ-ZRP71VHA PUHZ-ZRP140VKA 2x PUHZ-ZRP140VKA Outdoor unit Power Supply Power Fans 230V-50Hz Current Fans 230V-50Hz Noise Level (5 m) 400Vx3 (**) PUHZ-ZRP100YKA PUHZ-ZRP125YKA PUHZ-ZRP140YKA PUHZ-ZRP200YKA PUHZ-ZRP250YKA PUHZ-ZRP100YKA PUHZ-ZRP125YKA PUHZ-ZRP140YKA PUHZ-ZRP200YKA PUHZ-ZRP250YKA PUHZ-ZRP125YKA PUHZ-ZRP200YKA PUHZ-ZRP250YKA PUHZ-ZRP250YKA 2x PUHZ-ZRP140YKA PUHZ-ZRP140YKA PUHZ-ZRP200YKA PUHZ-ZRP250YKA PUHZ-ZRP250YKA 2x PUHZ-ZRP140YKA kW 0,642 0,856 0,856 1,070 1,280 0,132 0,198 0,198 0,264 0,330 0,396 0,642 0,856 1,284 1,498 1,712 1,712 0,225 0,300 0,450 0,525 0,600 0,600 A 2,85 3,80 3,80 4,75 5,70 1,14 1,71 1,71 2,28 2,85 3,42 2,85 3,80 5,70 6,65 7,60 7,60 1,95 2,60 3,90 4,55 5,20 5,20 dB(A) 57 58 58 59 60 56 57 57 58 59 60 57 58 59 60 61 61 61 62 63 64 65 65 Weight Recom. Height Up to Price kg 53 69 69 86 103 35 53 53 69 86 103 50 59 92 96 109 109 50 59 92 96 109 109 m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 4,2 4,2 euros consult consult consult consult consult consult consult consult consult consult consult consult consult consult consult consult consult consult consult consult consult consult consult Pipes Minimum Lenght Pipes Maximum Lenght Pipes Maximum Height m - m 50 75 75 75 75 75 75 100 100 m 30 30 30 30 30 30 30 30 30 (*) DX is also applicable to the models: Recessed Windbox, Smart, Dam, Recessed Dam, Deco, Variwind, Rund, Zen, Rotowind, Invisair. 33/2 Coil with double circuit and two outdoor units of 16kW. (**) Air curtains supply is always 230Vx1. MITSUBISHI Digital Inverter Outdoor Units PUHZ-ZRP71VHA PUHZ-ZRP100VKA PUHZ-ZRP100YKA PUHZ-ZRP125VKA PUHZ-ZRP125YKA PUHZ-ZRP140VKA PUHZ-ZRP140YKA PUHZ-ZRP200YKA PUHZ-ZRP250YKA Heating Capacity Heating Power SCOP or COP (*) Cooling Capacity Cooling Power SEER or EER (*) Power Supply Pipes Gas Liquid kW 8,0 11,2 11,2 14,0 14,0 16,0 16,0 22,4 27,0 kW 2,03 2,06 2,06 3,63 3,63 4,20 4,20 6,94 8,94 W/W 3,90 4,20 4,20 3,86 3,86 3,81 3,81 3,23 3,75 kW 7,1 10,0 10,0 12,5 12,5 13,4 13,4 19,0 22,0 kW 2,01 2,63 2,63 4,05 4,05 4,36 4,36 6,46 8,31 W/W 5,60 5,60 5,50 3,09 3,09 3,07 3,07 2,94 2,65 230Vx1 230Vx1 400Vx3 230Vx1 400Vx3 230Vx1 400Vx3 400Vx3 400Vx3 5/8 5/8 5/8 5/8 5/8 5/8 5/8 1 1 (*) Energy efficiency: SCOP and SEER seasonal ratio under 12kW and COP and EER over 12kW. 28 inch 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 1/2 WINDBOX M,ECM,G,ECG DX | Heat Pump Energy Saving Air Curtains For HITACHI Outdoor Units • Energy saving heat pump air curtains: Up to 70% reduction in costs and CO2 emissions (heating mode). • Self-supporting casing construction made of galvanized steel plate, finished in structural epoxy-polyester painting white colour RAL9016 as standard. Other colours or stainless steel are available on request. • Micro-perforated inlet grille with filter functions and easy service. Internal prefilter included. • Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side. • Double-inlet centrifugal fans driven by an external rotor motor and low noise level. 5-speed selector. “EC” models assembled with very low consumption efficiency fans. • Includes direct expansion coil with sensors. Optional condensate water pump. • Plug&Play control panel, infrared remote IR and 7m telephone cable included. • HITACHI DX Interface KIT with expansion valve and programmable control included. • Ready to connect to HITACHI Reversible DC Inverter outdoor heat pump unit (R410A). Model (*) Airflow m3/h 2160 3600 2460 4100 4920 2100 2800 4200 4900 4900 5600 2190 2190 2920 2920 4380 5110 5110 5840 M 1500 DX11-HI M 2500 DX22-HI ECM 1500 DX11-HI ECM 2500 DX22-HI ECM 3000 DX28-HI G 1000 DX8-HI G 1500 DX16-HI G 2000 DX22-HI G 2500 DX22-HI G 2500 DX28-HI G 3000 DX28-HI ECG 1000 DX8-HI ECG 1000 DX11-HI ECG 1500 DX14-HI ECG 1500 DX16-HI ECG 2000 DX22-HI ECG 2500 DX22-HI ECG 2500 DX28-HI ECG 3000 DX28-HI Outdoor unit Power Supply 230Vx1 RAS-4H(V)NCE RAS-4H(V)NCE RAS-3HVNC RAS-6H(V)NCE RAS-3HVNC RAS-4H(V)NCE RAS-5H(V)NCE RAS-6H(V)NCE - Power Fans 230V-50Hz kW 0,642 1,070 0,198 0,330 0,396 0,642 0,856 1,284 1,498 1,498 1,712 0,225 0,225 0,300 0,300 0,450 0,525 0,525 0,600 Outdoor unit Power Supply 400Vx3 (**) RAS-4H(V)NCE RAS-8HNCE RAS-4H(V)NCE RAS-8HNCE RAS-10HNCE RAS-6H(V)NCE RAS-8HNCE RAS-8HNCE RAS-10HNCE RAS-10HNCE RAS-4H(V)NCE RAS-5H(V)NCE RAS-6H(V)NCE RAS-8HNCE RAS-8HNCE RAS-10HNCE RAS-10HNCE Current Fans 230V-50Hz A 2,85 4,75 1,71 2,85 3,42 2,85 3,80 5,70 6,65 6,65 7,60 1,95 1,95 2,60 2,60 3,90 4,55 4,55 5,20 Noise Level (5 m) dB(A) 57 59 57 59 60 57 58 59 60 60 61 61 61 62 62 63 64 64 65 Weight kg 53 86 53 86 103 50 59 92 96 96 109 50 50 59 59 92 96 96 109 Recom. Height Up to m 3,5 3,5 3,8 3,8 3,8 3,8 3,8 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 4,2 4,2 4,2 4,2 Price euros consult consult consult consult consult consult consult consult consult consult consult consult consult consult consult consult consult consult consult (*) DX is also applicable to the models: Recessed Windbox, Smart, Dam, Recessed Dam, Deco, Variwind, Rund, Zen, Rotowind, Invisair. (**) Air curtains supply is always 230Vx1. HITACHI Reversible DC Inverter Outdoor Units RAS-3HVNC RAS-4H(V)NCE RAS-5H(V)NCE RAS-6H(V)NCE RAS-8HNCE RAS-10HNCE Heating Capacity Heating Power SCOP or COP (*) Cooling Capacity Cooling Power SEER or EER (*) Power Supply Pipes Gas Liquid kW 8,0 11,2 14,0 16,0 22,4 28,0 kW 1,90 2,54 3,39 4,23 5,28 7,12 W/W 4,21 4,41 4,12 3,78 4,24 3,93 kW 7,1 10,0 12,5 14,0 20,0 25,0 kW 1,94 2,44 3,53 4,25 5,95 7,81 W/W 3,66 4,10 3,54 3,29 3,36 3,20 230Vx1 230Vx1/400Vx3 230Vx1/400vX3 230Vx1/400vX3 400Vx3 400Vx3 5/8 5/8 5/8 5/8 1 1 inch 3/8 3/8 3/8 3/8 3/8 1/2 Pipes Maximum Lenght Pipes Maximum Height m 50 70 75 75 100 100 m 30 30 30 30 30 30 (*) Energy efficiency: SCOP and SEER seasonal ratio under 12kW and COP and EER over 12kW Special Finishes RAL chart Stainless steel casing AISI 304 Accessories IR CONTROL CLEVER IN-NE-II SPWR SLB/SPCT SPF-MG SPJ2-MG 29 WINDBOX L,XL | High Pressure Air Curtains For Commercial And Industrial Doors • Self-supporting casing construction made of galvanized steel plate, finished in structural epoxy-polyester painting white colour RAL9016 as standard. Other colours or stainless steel are available on request. • Two frontal grille options. Industrial perforated by default. • Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side. • Double-inlet centrifugal fans driven by an external rotor motor and low noise level. 5-speed selector. • “P” type with water heated coil. “E” type with electrical shielded elements, three stages with integrated regulation. “A” type without heating, air only. Optional expansion DX coil. • Includes Plug&Play control with 10m RJ45 cable and infrared remote control. Optional: Clever control (programmable, automatic, intelligent, energy saving, Modbus RTU for BMS…). AIR ONLY Model L 1000 A L 1500 A L 2000 A L 2500 A L 3000 A XL 1000 A XL 1500 A XL 2000 A XL 2500 A XL 3000 A Airflow m3/h 4000 6000 8000 10000 12000 5300 7950 10600 13250 15900 Power Fans 230V-50Hz kW 1,04 1,56 2,08 2,60 3,12 1,40 2,10 2,80 3,50 4,20 Airflow m3/h 4000 6000 8000 10000 12000 5300 7950 10600 13250 15900 Electrical Heating Capacity 400Vx3-50Hz kW 10/15/25 15/22,5/37,5 20/30/50 20/40/60 20/40/60 10/15/25 15/22,5/37,5 20/30/50 20/40/60 20/40/60 ELECTRICAL HEATED Model L 1000 E L 1500 E L 2000 E L 2500 E L 3000 E XL 1000 E XL 1500 E XL 2000 E XL 2500 E XL 3000 E 30 Current Fans 230V-50Hz A 4,40 6,60 8,80 11,00 13,20 6,00 9,00 12,00 15,00 18,00 Power Fans 230V-50Hz kW 1,04 1,56 2,08 2,60 3,12 1,40 2,10 2,80 3,50 4,20 Noise Level (5 m) dB(A) 63 64 65 66 67 65 66 67 68 69 Current Fans 230V-50Hz A 4,40 6,60 8,80 11,00 13,20 6,00 9,00 12,00 15,00 18,00 Noise Level (5 m) dB(A) 63 64 65 66 67 65 66 67 68 69 Weight kg 72 108 145 177 213 78 117 157 192 211 Weight kg 90 135 180 225 270 95 144 192 240 288 Recommended Height Up to m 5 5 5 5 5 7 7 7 7 7 Recommended Height Up to m 5 5 5 5 5 7 7 7 7 7 Price euros 3.273 4.116 5.259 6.333 7.557 3.543 4.521 5.799 7.008 8.367 Price euros 5.019 6.618 8.310 10.050 11.805 5.289 7.023 8.850 10.725 12.615 WINDBOX L,XL | WATER HEATED Model Airflow m3/h 3800 5700 7600 9500 11400 4900 7350 9800 12250 14700 L 1000 P L 1500 P L 2000 P L 2500 P L 3000 P XL 1000 P XL 1500 P XL 2000 P XL 2500 P XL 3000 P High Pressure Air Curtains For Commercial And Industrial Doors P86 Heating Capacity 80/60ºC kW 19,68 29,64 43,01 56,01 69,27 22,68 34,52 50,10 65,29 80,79 P64 Heating Capacity 60/40ºC kW 16,18 25,92 35,58 45,55 56,78 18,98 30,45 41,83 53,56 66,78 P54 Heating Capacity 50/40ºC kW 17,18 29,04 38,93 49,36 59,96 20,43 34,55 46,36 58,81 71,47 Power Fans 230Vx1 kW 1,04 1,56 2,08 2,60 3,12 1,40 2,10 2,80 3,50 4,20 Current Fans 230Vx1 A 4,40 6,60 8,80 11,00 13,20 6,00 9,00 12,00 15,00 18,00 Noise Level (5 m) dB(A) 62 63 64 65 66 64 65 66 67 68 Weight kg 89 128 171 214 260 94 137 183 227 278 Recom. Height Up to m 5 5 5 5 5 7 7 7 7 7 P86 Price euros 3.858 4.830 6.138 7.593 9.120 4.128 5.235 6.678 8.268 9.930 P64 Price euros 3.942 4.980 6.318 7.845 9.507 4.212 5.385 6.858 8.520 10.317 P54 Price euros 4.077 5.139 6.507 8.142 9.876 4.347 5.544 7.047 8.817 10.686 Water heated: P86 2 rows coil, P64 3 rows coil, P54 4 rows coil. 2x1” for 1000 and 1500, 2x1¼” for 2000 and 2500, 2x1½” for 3000. Connection pipes P86, P64 and P54 are female (male if lateral pipes). Installation Options Model 1000 1500 2000 2500 3000 Telescopic outlet kit euros 407 437 512 565 955 Telescopic inlet kit euros 408 442 516 571 965 Telescopic false ceiling kit euros 815 879 1.028 1.136 1.920 Telescopic false ceiling kit + plenum euros 1.267 1.378 1.598 1.774 3.000 Plenum surface mounting euros 452 499 570 638 1.080 Special Finishes Painting according RAL chart or metallic Stainless steel casing AISI 304 Accessories IR CONTROL CLEVER CH-5HW-NE TD-NE IN-NE-II DC V-S/M V-T AFS-INS SPWR SLB/SPCT SPF-LXL SPJ2-LXL 31 INVISAIR | Recessed Air Curtains For Commercial and Industrial Doors • Specially designed for applications where the body of the air curtain is to be installed inside a column or bulkhead for architectural reasons. It can be vertically or horizontally mounted. • Self-supporting casing construction made of galvanized steel plate, finished in structural epoxy-polyester painting white colour RAL9016 as standard. Other colours or stainless steel are available on request. • The air flow of Invisair follows a straight line from the air inlet grille to the to the discharge. Inlet area inside a bulkhead or column should be designed with suitable grille provided by others. • Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side. • Double-inlet centrifugal fans driven by an external rotor motor and low noise level. 5-speed selector. “EC” models assembled with very low consumption efficiency fans. • “P” type with water heated coil. “E” type with electrical shielded elements, three stages with integrated regulation. “A” type without heating, air only. Optional expansion DX coil. • Includes Plug&Play control with 7m RJ45 cable and infrared remote control. Optional: Clever control (programmable, automatic, intelligent, energy saving, Modbus RTU for BMS…) AIR ONLY Model IM 1500 A IM 2000 A IM 2500 A IG 1500 A IG 2000 A IG 2500 A IECG 1500 A IECG 2000 A IECG 2500 A Airflow m3/h 2640 3960 4620 3200 4800 5600 3600 5400 6300 Power Fans 230V-50Hz kW 0,424 0,636 0,742 0,856 1,284 1,498 0,300 0,450 0,525 Airflow m3/h 2640 3960 4620 3200 4800 5600 3600 5400 6300 Electrical Heating Capacity 400Vx3-50Hz kW 4/8/12 6/12/18 6/12/18 7,5/15/22,5 10/20/30 10/20/30 7,5/15/22,5 10/20/30 10/20/30 ELECTRICAL HEATED Model IM 1500 E IM 2000 E IM 2500 E IG 1500 E IG 2000 E IG 2500 E IECG 1500 E IECG 2000 E IECG 2500 E 32 Current Fans 230V-50Hz A 1,88 2,82 3,29 3,80 5,70 6,65 2,60 3,90 4,55 Power Fans 230V-50Hz kW 0,424 0,636 0,742 0,856 1,284 1,498 0,300 0,450 0,525 Noise Level (5 m) dB(A) 56 57 58 58 59 60 62 63 64 Current Fans 230V-50Hz A 1,88 2,82 3,29 3,80 5,70 6,65 2,60 3,90 4,55 Noise Level (5 m) dB(A) 56 57 58 58 59 60 62 63 64 Weight kg 55 68 73 60 78 83 60 78 83 Weight kg 67 86 93 73 96 103 73 96 103 Recommended Height Up to m 3,5 3,5 3,5 3,8 3,8 3,8 4,2 4,2 4,2 Recommended Height Up to m 3,5 3,5 3,5 3,8 3,8 3,8 4,2 4,2 4,2 Price euros 2.763 3.366 3.933 2.913 3.558 4.116 3.213 4.050 4.722 Price euros 3.702 4.416 5.289 3.897 4.918 5.870 4.200 5.478 6.555 INVISAIR | Recessed Air Curtains For Commercial and Industrial Doors WATER HEATED Airflow Model IM 1500 P IM 2000 P IM 2500 P IG 1500 P IG 2000 P IG 2500 P IECG 1500 P IECG 2000 P IECG 2500 P m3/h 2480 3720 4340 3000 4500 5250 3400 5100 5950 P86 Heating Capacity 80/60ºC kW 14,23 22,17 27,69 16,02 24,92 31,16 17,29 26,86 33,63 P64 Heating Capacity 60/40ºC kW 13,65 19,70 23,48 15,47 22,29 26,61 16,77 24,14 28,84 P54 Heating Capacity 50/40ºC kW 16,37 23,15 28,76 17,86 25,24 31,38 Power Fans 230Vx1 kW 0,424 0,636 0,742 0,856 1,284 1,498 0,300 0,450 0,525 Current Fans 230Vx1 A 1,88 2,82 3,29 3,80 5,70 6,65 2,60 3,90 4,55 Noise Level (5 m) dB(A) 56 57 58 58 59 60 62 63 64 Weight kg 63 78 86 69 89 94 69 89 94 Recom. Height Up to m 3,5 3,5 3,5 3,8 3,8 3,8 4,2 4,2 4,2 P86 Price euros 3.105 3.774 4.584 3.252 3.963 4.746 3.546 4.446 5.364 P64 Price euros 3.198 3.933 4.803 3.339 4.110 4.950 3.639 4.608 5.583 P54 Price euros 3.498 4.299 5.247 3.798 4.797 5.880 Water heated: connection pipes P86 and P64 are 2x3/4” female (male if lateral pipes), P54 2x1” male. P86 2 rows coil, P64 3 rows coil, P54 4 rows coil. Installation Options On top horizontal mounting Vertical left side Installation Vertical right side Installation Special Finishes Painting according RAL chart or metallic Accessories IR CONTROL CLEVER CH-5HW-NE TD-NE IN-NE-II DC V-S/M V-T AFS-INS SPWR SLB/SPCT SPF-INV SPJ2-INV 33 ROTOWIND | Air Curtains For Revolving Doors • Specially designed to be installed in all type of revolving doors. Two possible layouts, tailored dimensions. • Self-supporting casing construction made of galvanized steel plate, finished in structural epoxy-polyester painting white colour RAL9016 as standard. Other colours or stainless steel are available on request. • Large perforated inlet grille avoiding intensive maintenance. • Circular anodized aluminium outlet vanes, airfoil shaped. • Double-inlet centrifugal fans driven by an external rotor motor and low noise level. 5-speed selector. “EC” models assembled with very low consumption efficiency fans. • “P” type with water heated coil. “E” type with electrical shielded elements, three stages with integrated regulation. “A” type without heating, air only. Optional expansion DX coil. • Includes Plug&Play control with 7m RJ45 cable and infrared remote control. Optional: Clever control (programmable, automatic, intelligent, energy saving, Modbus RTU for BMS…). AIR ONLY Model ROTO M 1000 A ROTO M 1500 A ROTO M 2000 A ROTO M 2500 A ROTO G 1000 A ROTO G 1500 A ROTO G 2000 A ROTO G 2500 A ROTO ECG 1000 A ROTO ECG 1500 A ROTO ECG 2000 A ROTO ECG 2500 A Airflow m3/h 1980 2640 3960 4620 2400 3200 4800 5600 2700 3600 5400 6300 Power Fans 230V-50Hz kW 0,318 0,424 0,636 0,742 0,642 0,856 1,284 1,498 0,225 0,300 0,450 0,525 Airflow m3/h 1980 2640 3960 4620 2400 3200 4800 5600 2700 3600 5400 6300 Electrical Heating Capacity 400Vx3-50Hz kW 3/6/9 4/8/12 6/12/18 6/12/18 5/10/15 7,5/15/22,5 10/20/30 10/20/30 5/10/15 7,5/15/22,5 10/20/30 10/20/30 ELECTRICAL HEATED Model ROTO M 1000 E ROTO M 1500 E ROTO M 2000 E ROTO M 2500 E ROTO G 1000 E ROTO G 1500 E ROTO G 2000 E ROTO G 2500 E ROTO ECG 1000 E ROTO ECG 1500 E ROTO ECG 2000 E ROTO ECG 2500 E 34 Current Fans 230V-50Hz A 1,41 1,88 2,82 3,29 2,85 3,80 5,70 6,65 1,95 2,60 3,90 4,55 Power Fans 230V-50Hz kW 0,318 0,424 0,636 0,742 0,642 0,856 1,284 1,498 0,225 0,300 0,450 0,525 Noise Level (5 m) dB(A) 55 56 57 58 57 58 59 60 61 62 63 64 Current Fans 230V-50Hz A 1,41 1,88 2,82 3,29 2,85 3,80 5,70 6,65 1,95 2,60 3,90 4,55 Noise Level (5 m) dB(A) 55 56 57 58 57 58 59 60 61 62 63 64 Weight kg - Weight kg - Recommended Height Up to m 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 Recommended Height Up to m 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 Price euros 5.385 5.844 7.056 7.698 5.415 5.886 7.077 7.872 5.724 6.303 7.725 8.502 Price euros 6.231 6.849 8.118 9.069 6.300 6.891 8.532 9.600 6.603 7.302 9.171 10.350 ROTOWIND | Air Curtains For Revolving Doors WATER HEATED Model ROTO M 1000 P ROTO M 1500 P ROTO M 2000 P ROTO M 2500 P ROTO G 1000 P ROTO G 1500 P ROTO G 2000 P ROTO G 2500 P ROTO ECG 1000 P ROTO ECG 1500 P ROTO ECG 2000 P ROTO ECG 2500 P Airflow m3/h 1860 2480 3720 4340 2250 3000 4500 5250 2550 3400 5100 5950 P86 Heating Capacity 80/60ºC kW 9,84 14,23 22,17 27,69 11,04 16,02 24,92 31,16 11,89 17,29 26,86 33,63 P64 Heating Capacity 60/40ºC kW 9,22 13,65 19,70 23,48 10,42 15,47 22,29 26,61 11,27 16,77 24,14 28,84 P54 Heating Capacity 50/40ºC kW 10,56 16,37 23,15 28,76 11,50 17,86 25,24 31,38 Power Fans 230Vx1 kW 0,318 0,424 0,636 0,742 0,642 0,856 1,284 1,498 0,225 0,300 0,450 0,525 Current Fans 230Vx1 A 1,41 1,88 2,82 3,29 2,85 3,80 5,70 6,65 1,95 2,60 3,90 4,55 Noise Level (5 m) dB(A) 55 56 57 58 57 58 59 60 61 62 63 64 Weight kg - Recom. Height Up to m 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 P86 Price euros 5.670 6.192 7.470 8.361 5.703 6.234 7.494 8.520 6.000 6.642 8.133 9.156 P64 Price euros 5.757 6.288 7.632 8.586 5.787 6.330 7.656 8.730 6.087 6.738 8.295 9.381 P54 Price euros 5.922 6.489 7.845 9.027 6.222 6.897 8.484 9.678 SLB SPCT Water heated: connection pipes P86 and P64 are 2x3/4” female (male if lateral pipes), P54 2x1” male. P86 2 rows coil, P64 3 rows coil, P54 4 rows coil. Installation and Layouts On top mounting False ceiling mounting Anchorage System Anchored onto the door Special Finishes RAL chart Stainless steel casing AISI 304 Hanging from the ceiling Accessories IR CONTROL CLEVER IN-NE-II DC V-S/M V-T AFS-INS 35 VARIWIND | Modular, Variable Length Air Curtains • Designed to be tailor-made, adaptable to any customer’s needs. • Option VP: Structure made of aluminium profiles and galvanized steel panels, finished white RAL 9016 as standard. Other colours are available on request. VP construction allow the service from the top and the bottom. Large perforated inlet grille avoiding intensive maintenance. • Option VW: Same construction as Windbox M-ECM-G-ECG. Self-supporting casing construction made of galvanized steel plate, finished in structural epoxypolyester painting white colour RAL9016 as standard. Other colours or stainless steel are available on request. Micro-perforated inlet grille with filter functions and easy service. It does not need prefilter. • Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side • Double-inlet centrifugal fans driven by an external rotor motor and low noise level. 5-speed selector. “EC” models assembled with very low consumption efficiency fans. • “P” type with water heated coil. “E” type with electrical shielded elements, three stages with integrated regulation. “A” type without heating, air only. Optional expansion DX coil. • Includes Plug&Play control with 7m RJ45 cable and infrared remote control. Optional: Clever control (programmable, automatic, intelligent, energy saving, Modbus RTU for BMS…). VP (with profiles) VW (windbox construction) AIR ONLY Model VARI M 1000 A VARI M 1500 A VARI M 2000 A VARI M 2500 A VARI ECM 1000 A VARI ECM 1500 A VARI ECM 2000 A VARI ECM 2500 A VARI G 1000 A VARI G 1500 A VARI G 2000 A VARI G 2500 A VARI ECG 1000 A VARI ECG 1500 A VARI ECG 2000 A VARI ECG 2500 A 36 Airflow m3/h 1800 2700 3600 4500 1840 2760 3680 4600 2400 3200 4800 5600 2700 3600 5400 6300 Power Fans 230Vx1 kW 0,212 0,318 0,424 0.530 0,132 0,198 0,264 0,330 0,642 0,856 1,284 1,498 0,225 0,300 0,450 0,525 Current Fans 230Vx1 A 0,94 1,41 1,88 2.35 1,14 1,71 2,28 2,85 2,85 3,80 5,70 6,65 1,95 2,60 3,90 4,55 Noise Level (5 m) dB(A) 55 56 57 58 56 57 58 59 57 58 59 60 61 62 63 64 Weight kg 31 46 58 72 31 46 58 72 43 51 80 84 43 51 80 84 Recommended Height Up to m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 Price euros 2.874 3.384 3.909 4.557 3.093 3.693 4.341 5.103 3.105 3.633 4.377 5.025 3.405 4.017 4.992 5.742 VARIWIND | Modular, Variable Length Air Curtains ELECTRICAL HEATED Model Airflow m3/h 1800 2700 3600 4500 1840 2760 3680 4600 2400 3200 4800 5600 2700 3600 5400 6300 VARI M 1000 E VARI M 1500 E VARI M 2000 E VARI M 2500 E VARI ECM 1000 E VARI ECM 1500 E VARI ECM 2000 E VARI ECM 2500 E VARI G 1000 E VARI G 1500 E VARI G 2000 E VARI G 2500 E VARI ECG 1000 E VARI ECG 1500 E VARI ECG 2000 E VARI ECG 2500 E WATER HEATED Model VARI M 1000 P VARI M 1500 P VARI M 2000 P VARI M 2500 P VARI ECM 1000 P VARI ECM 1500 P VARI ECM 2000 P VARI ECM 2500 P VARI G 1000 P VARI G 1500 P VARI G 2000 P VARI G 2500 P VARI ECG 1000 P VARI ECG 1500 P VARI ECG 2000 P VARI ECG 2500 P Airflow m3/h 1660 2490 3320 4150 1720 2580 3440 4300 2250 3000 4500 5250 2550 3400 5100 5950 P86 Heating Capacity 80/60ºC kW 9,17 14,26 20,65 26,92 9,38 14,58 21,12 27,53 11,04 16,02 24,92 31,16 11,89 17,29 26,86 33,63 Electrical Heating Capacity 400Vx3-50Hz kW 3/6/9 4/8/12 6/12/18 6/12/18 3/6/9 4/8/12 6/12/18 6/12/18 5/10/15 7,5/15/22,5 10/20/30 10/20/30 5/10/15 7,5/15/22,5 10/20/30 10/20/30 P64 Heating Capacity 60/40ºC kW 8,56 13,69 18,26 22,12 8,77 14,02 18,70 23,33 10,42 15,47 22,29 26,61 11,27 16,77 24,14 28,84 Power Fans 230Vx1 kW 0,212 0,318 0,424 0,530 0,132 0,198 0,264 0,330 0,642 0,856 1,284 1,498 0,225 0,300 0,450 0,525 P54 Heatin Capacity 50/40ºC kW 8,52 14,34 18,65 24,32 8,74 14,71 19,13 24,95 10,56 16,37 23,15 28,76 11,50 17,86 25,24 31,38 Current Fans 230Vx1 A 0,94 1,41 1,88 2,35 1,14 1,71 2,28 2,85 2,85 3,80 5,70 6,65 1,95 2,60 3,90 4,55 Power Fans 230Vx1 kW 0,428 0,642 0,856 1,070 0,132 0,198 0,264 0,330 0,642 0,856 1,284 1,498 0,225 0,300 0,450 0,525 Current Fans 230Vx1 A 1,90 2,85 3,80 4,75 1,14 1,71 2,28 2,85 2,85 3,80 5,70 6,65 1,95 2,60 3,90 4,55 Noise Level (5 m) dB(A) 55 56 57 58 56 57 58 59 57 58 59 60 61 62 63 64 Noise Level (5 m) dB(A) 56 57 58 59 56 57 58 59 57 58 59 60 61 62 63 64 Weight kg 37 57 75 94 37 57 75 94 52 63 100 106 52 63 100 106 Weight kg 35 53 69 86 35 53 69 86 50 59 92 96 50 59 92 96 Recom. Height Up to m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 Recommended Height Up to m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 P86 Price euros 3.159 3.726 4.335 5.211 3.366 4.023 4.737 5.742 3.387 3.972 4.779 5.655 3.669 4.329 5.367 6.351 Price euros 3.705 4.305 4.941 5.892 3.915 4.614 5.373 6.444 3.972 4.617 5.754 6.813 4.260 4.983 6.366 7.533 P64 Price euros 3.243 3.819 4.491 5.430 3.447 4.116 4.893 5.958 3.468 4.059 4.926 5.859 3.753 4.419 5.505 6.567 P54 Price euros 3.378 3.978 4.680 5.727 3.582 4.275 5.082 6.255 3.603 4.218 5.115 6.156 3.888 4.578 5.694 6.864 Water heated: connection pipes P86 and P64 are 2x3/4” female (male if lateral pipes), P54 2x1” male. P86 2 rows coil, P64 3 rows coil, P54 4 rows coil. Special Finishes Painting according RAL chart or metallic Accessories IR CONTROL CLEVER CH-5HW-NE TD-NE IN-NE-II DC V-S/M V-T AFS-INS SPWR SLB SPCT 37 KOOL | High Velocity Air Curtains For Cold Stores And Freezers • Specially designed to be installed in doors of cold stores and freezers. • Self-supporting casing construction made of galvanized steel plate, finished in structural epoxy-polyester painting white colour RAL9016 as standard. Other colours or stainless steel are available on request. • Large perforated inlet grille avoiding intensive maintenance. Also available with flat micro-perforated inlet grille, more elegant for commercial doors where heating is not needed. • Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side. • Double-inlet centrifugal fans driven by an external rotor motor and low noise level. 5-speed selector. “EC” models assembled with very low consumption efficiency fans. • Includes Plug&Play control with 7m RJ45 cable and infrared remote control. Optional: Clever control (programmable, automatic, intelligent, energy saving, Modbus RTU for BMS…). AIR ONLY Model Power Fans 230V-50Hz kW 0,212 0,318 0,424 0,530 0,636 0,132 0,198 0,264 0,330 0,396 0,642 0,856 1,284 1,498 1,712 0,225 0,300 0,450 0,525 0,600 Airflow m3/h 1800 2700 3600 4500 5400 1840 2760 3680 4600 5520 2400 3200 4800 5600 6400 2700 3600 5400 6300 7200 KM 1000 A KM 1500 A KM 2000 A KM 2500 A KM 3000 A KECM 1000 A KECM 1500 A KECM 2000 A KECM 2500 A KECM 3000 A KG 1000 A KG 1500 A KG 2000 A KG 2500 A KG 3000 A KECG 1000 A KECG 1500 A KECG 2000 A KECG 2500 A KECG 3000 A Current Fans 230V-50Hz A 0,94 1,41 1,88 2,35 2,82 1,14 1,71 2,28 2,85 3,42 2,85 3,80 5,70 6,65 7,60 1,95 2,60 3,90 4,55 5,20 Noise Level (5 m) dB(A) 55 56 57 58 59 56 57 58 59 60 57 58 59 60 61 61 62 63 64 65 Weight kg 29 44 53 58 76 33 50 61 68 76 37 55 71 78 86 37 56 71 78 86 Recommended Height Up to m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 4,2 Special Finishes Painting according RAL chart or metallic Stainless steel AISI 304 Accessories IR CONTROL 38 CLEVER IN-NE-II DC SPT3 SPWR SLB SPCT SPF-KOOL SPJ2-KOOL Price euros 1.383 1.692 2.061 2.583 3.573 1.614 2.040 2.535 3.168 4.275 1.626 1.944 2.523 3.045 4.050 1.935 2.364 3.174 3.807 4.908 TRIOJET SYSTEM | Air Curtains Combination System with Multijets For Large Cold Stores And Freezers • Specially designed to be installed on doors of industrial cold stores and freezers with big temperature differences. • Reduces mist, snow and ice decreasing risk of accidents. • System composed by two air curtains: Special Duojet air curtain with plenum and Kool air curtain. The result is a combination system of 3 jets at different temperatures and different speeds. • High efficiency barrier against big amount of thermal losses due to a big temperature difference (shorter payback). • Structure support with lateral walls to cover 100% of the opening with 3 jets should be provided by others. • Self-supporting casing construction made of galvanized steel plate, finished in structural epoxy-polyester painting white colour RAL9016 as standard. Other colours or stainless steel are available on request. • Large perforated inlet grille avoiding intensive maintenance. • Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side. • Duojet with IP55 AC centrifugal fans and Kool with EC fans (both double inlet, external rotor motors and built-in thermal protection contact). All provided with 5-speed selection, very low noise level. • Includes electrical shielded element of 3 power stages with integrated regulation. • Triojet is automatically fully controlled by Clever Control. Electronics and controller protected inside IP65 boxes. Plug & Play connections. • Ready for BMS connection via Modbus RTU. Model TRIOJET 1000 TRIOJET 1500 TRIOJET 2000 TRIOJET 2500 TRIOJET 3000 Airflow m3/h 5900 8400 11800 14300 16800 Fans Power 230V-50Hz kW 1,08 1,58 2,16 2,66 3,17 Fans Current 230V-50Hz A 5,75 8,30 11,50 14,05 16,60 Electrical Heating Capacity 400Vx3-50Hz kW 3/6/9 4/8/12 6/12/18 6/12/18 8/16/24 Noise Level (5 m) dB(A) 62 63 64 65 66 Weight kg 125 182 234 275 314 Recommended Height Up to m 3 3 3 3 3 Price euros consult consult consult consult consult Special Finishes Painting according RAL chart or metallic Stainless steel casing AISI 304 39 MAXWELL | Air Curtains For Industrial Doors • High performance industrial air curtains for vertical or horizontal installations for large industrial doors. Available in 1.5, 2.0 and 2.5 meters length. Easy dockable modules to reach large dimensions. • Heavy self-supporting casing construction made of galvanized steel plate, finished in structural epoxy-polyester painting white colour RAL9016 as standard. Other colours are available on request. • Double outlet with Coanda effect to achieve larger and efficient air jet. Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side. • High efficiency and low noise axial fans, driven with external rotor motor single phase 230V. Optionally three phase 400V. Provided with 5-speed selection. Maintenance free. • “P” type with water heated coil. “A” type without heating, air only. • Regulation not included. Optional: Basic regulation with Plug&Play control panel, 10m RJ45 cable and remote control. Advanced regulation with Clever (automatic, intelligent, energy saving, Modbus RTU for BMS…). AIR ONLY Model MXW 1500 A MXW 2000 A MXW 2500 A Airflow m3/h 7000 10500 14000 WATER HEATED Model MXW 1500 P MXW 2000 P MXW 2500 P Power Fans 230V-50Hz kW 0,68 1,02 1,36 Airflow m3/h 6800 10200 13600 P86 Heating Capacity 80/60ºC kW 41,39 61,25 80,05 Current Fans 230V-50Hz A 2,96 4,44 5,92 P64 Heating Capacity 60/40ºC kW 34,09 50,16 66,19 Power Fans 230Vx1 kW 0,68 1,02 1,36 Noise Level (5 m) dB(A) 60 61 62 Current Fans 230Vx1 A 2,96 4,44 5,92 Noise Level (5 m) dB(A) 59 60 61 Weight kg 79 103 126 Weight kg 95 126 158 Recommended Height Up to m 6 6 6 Recom. Height Up to m 6 6 6 P86 Price euros 2.520 3.342 4.185 Price euros 2.130 2.829 3.543 P64 Price euros 2.637 3.516 4.392 Water heated: P86 2 rows coil, P64 3 rows coil. Electrical heated models available on customer request. Let us know your needs. Special Finishes Painting according RAL chart or metallic Accessories IR CONTROL CLEVER 40 CH-5HW-NE IN-NE-II DC V-S/M V-T AFS-INS SPWR SLB/SPCT SPF-MXW SPJ2-MXW MAX | Air Curtains For Industrial Doors • High performance industrial air curtains for vertical or horizontal installations for large industrial doors. Easy dockable modules to reach large dimensions. • Heavy casing made of double chamber aluminium profiles and galvanized plated steel panels, finished in structural epoxy-polyester painting white colour RAL9016 as standard. Other colours are available on request. • Double outlet with Coanda effect to achieve larger and efficient air jet. Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side. • High efficiency and low noise axial fans, driven with external rotor motor single phase 230V. Optionally three phase 400V. Provided with 5-speed selection. Maintenance free. • “P” type with water heated coil. “E” type with electrical shielded elements, three stages with integrated regulation. “A” type without heating, air only. • Includes Plug&Play control with 10m RJ45 cable and infrared remote control. Optional: Clever control (programmable, automatic, intelligent, energy saving, Modbus RTU for BMS…). AIR ONLY Model MAX 2 A MAX 3 A MAX 4 A MAX 5 A MAX 6 A Airflow m3/h 6600 9900 13200 16500 19800 Power Fans 230V-50Hz kW 0,68 1,02 1,36 1,70 2,04 Airflow m3/h 6600 9900 13200 16500 19800 Electrical Heating Capacity 400Vx3-50Hz kW 15/25/40 22,5/37,5/60 30/50/80 30/60/90 30/60/90 ELECTRICAL HEATED Model MAX 2 E MAX 3 E MAX 4 E MAX 5 E MAX 6 E WATER HEATED Model MAX 2 P MAX 3 P MAX 4 P MAX 5 P MAX 6 P Airflow m3/h 6400 9600 12800 16000 19200 P86 Heating Capacity 80/60ºC kW 28,74 51,77 74,15 96,43 118,69 P64 Heating Capacity 60/40ºC kW 29,71 47,10 63,30 82,16 91,92 Current Fans 230V-50Hz A 2,96 4,44 5,92 7,40 8,88 Power Fans 230V-50Hz kW 0,68 1,02 1,36 1,70 2,04 Noise Level (5 m) dB(A) 62 63 64 65 66 Current Fans 230V-50Hz A 2,96 4,44 5,92 7,40 8,88 Power Fans 230Vx1 kW 0,68 1,02 1,36 1,70 2,04 Current Fans 230Vx1 A 2,96 4,44 5,92 7,40 8,88 Noise Level (5 m) dB(A) 62 63 64 65 66 Noise Level (5 m) dB(A) 61 62 63 64 65 Weight kg 59 79 103 124 151 Weight kg 74 100 133 159 186 Weight kg 75 102 135 162 189 Recommended Height Up to m 6 6 6 6 6 Recommended Height Up to m 6 6 6 6 6 Recom. Height Up to m 6 6 6 6 6 P86 Price euros 3.939 4.938 6.066 7.299 9.186 Price euros 2.739 3.576 4.380 5.355 6.912 Price euros 5.842 7.239 8.385 9.802 12.221 P64 Price euros 4.296 5.475 6.738 8.079 10.074 Water heated: P86 2 rows coil, P64 3 rows coil. Special Finishes Painting according RAL chart or metallic Accessories IR CONTROL CLEVER CH-5HW-NE TD-NE IN-NE-II DC V-S/M V-T AFS-INS SPWR SLB/SPCT SPF-MAX SPJ2-MAX 41 Compact Recessed High Velocity Air Curtains RECESSED COMPACT | For Commercial and Industrial Doors • Compact and low profile air only recessed air curtain, with full grille view, specially designed for applications without heating. • Self-supporting casing construction made of galvanized steel plate, ready to be installed recessed in a false ceiling. • Inlet grille (free of maintenance) made with aluminium profiles and blow-out nozzle, integrated in a single white frame colour RAL 9016. Other colours are available on request. • Anodized aluminium outlet vanes, airfoil shaped, adjustable in both directions. • Double-inlet centrifugal fans driven by an external rotor motor and low noise level. 5-speed selector. “EC” models assembled with very low consumption efficiency fans. • Includes Plug&Play control with 7m RJ45 cable and infrared remote control. Optional: Clever control (programmable, automatic, intelligent, energy saving, Modbus RTU for BMS…). AIR ONLY Model RC M 1000 A RC M 1500 A RC M 2000 A RC M 2500 A RC ECM 1000 A RC ECM 1500 A RC ECM 2000 A RC ECM 2500 A RC G 1000 A RC G 1500 A RC G 2000 A RC G 2500 A RC ECG 1000 A RC ECG 1500 A RC ECG 2000 A RC ECG 2500 A Airflow m3/h 1800 2700 3600 4500 1840 2760 3680 4600 2400 3200 4800 5600 2700 3600 5400 6300 Power Fans 230V-50Hz kW 0,212 0,318 0,424 0,530 0,132 0,198 0,264 0,330 0,642 0,856 1,284 1,498 0,225 0,300 0,450 0,525 Current Fans 230V-50Hz A 0,94 1,41 1,88 2,35 1,14 1,71 2,28 2,85 2,85 3,80 5,70 6,65 1,95 2,60 3,90 4,55 Noise Level (5 m) dB(A) 55 56 57 58 56 57 58 59 57 58 59 60 61 62 63 64 Recommended Height Up to m 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,8 3,8 3,8 3,8 4,2 4,2 4,2 4,2 Weight kg 33 50 61 68 33 50 61 68 37 55 71 78 37 56 71 78 Special Finishes Inlet and outlet grille painting according RAL chart or metallic Accessories IR CONTROL 42 CLEVER IN-NE-II DC SPWR SLB SPCT SPANG-SIL Price euros 1.683 2.121 2.547 2.976 1.905 2.457 2.961 3.501 1.914 2.379 3.015 3.456 2.211 2.766 3.579 4.119 ACCESSORIES Feet, wall or celing supports, tailor made arms, vibration dampers… Thermostatic valve, solenoid valve (ON/OFF), modulating valves... Anti-freeze sensor, door contact, ambient thermostat, external temperature sensor… Telephone cables: RJ45, RJ11, different lengths... SPECIAL OPTIONS Airtècnics, as an air curtains specialist, can produce units with special requirements under request. Here there are some of the possibilities: • External alarm signals as: unit working, heating ON, airflow switch, dirty grille, electronic overheating signal, fans overheating thermo contact TK, electrical heating blocked, etc. • Special water or steam coils for higher temperatures or different power than standard • Tailor made electrical heating elements at desired power and power supply • Electrical heated air curtains from 400Vx3 to 230Vx3 or 230Vx1 • Dummies (empty air curtains) to combine with working units • Industrial air curtains at 400Vx3 with the same advantages of electronic regulation 5 speed range • Industrial MAX with higher volume (MAX L) • Industrial MAX with explosion proof EX fans • Stainless steel AISI-316 or other materials under request • Special RAL colour wiht gloss or other finishes. Special BS (British Standard), Tiger Drylac, etc. • Complete tailor made air curtain or our standard range customized according to client needs Please consult us for further information or other options. 43 BASIC REGULATION: Standard Controls Two ranges of control panels, both designed for easy and quick Plug & Play connection, free of mistakes, by using a telephone cable with RJ45 connectors. The digital communication between the control panel and air curtain is a very reliable connection without information losses even at long distances. All control panels can be turned ON/OFF externally and have internal memory (if the power supply is cut off, the unit goes back to the selected state). 2-Speed Range Controls Suitable for Optima and Recessed Optima air curtains. Infrared remote control included. CW-2EV-IR Water heated 2 fan speed and electro-valve switch CA-2AO-IR Only air and water heated 2 fan speed CE-2AO-IR Electrical heated 2 fan speed 2 heating stages 5-Speed Range Controls Suitable for Windbox M,ECM,G,ECG,L,XL, Dam, Smart, Recessed Windbox, Recessed Dam, Recessed Compact, Kool, Zen, Rund, Deco, Rotowind, Invisair, Variwind, Max and Maxwell air curtains. Infrared remote control included. CA-5AW-IR Only air 5 fan speed CW-5AW-IR Water heated, 5 fan speed and electro-valve switch CE-5AW-IR Electrical heated, 5 fan speed and 3 heating stages CD-5AW-IR Heat pump heated, 5 fan speed and heating ON/OFF Optional Controls Hand Auto Water heated: with manual and automatic operating. Auxiliary functions: anti-freezing sensor, door contact (with delay) and room thermostat. CH-2HO-NE CH-5HW-NE Digital Thermostat Only electrical heated: modifies heat stages and fan speed depending on temperature and selected program. TD-NE Interface Allows the connection to a centralized management system like BMS and also to standard controllers. IN-NE-II Multiple connection Easy to manage several units using only one control panel. 44 ADVANCED REGULATION: Clever Control The future is here with the new generation Clever control. Maximum control with maximum energy saving. Intelligent PCB Box Clever Control automatically adapts the functioning of the air curtain to the entrance conditions, mantainig comfort while saving energy. It optimizes the ventilation and heating to make an efficient barrier for an optimal climate separation. Air Curtain Outdoor Temperature Indoor Temperature Door State Intelligent Proactive Regulation Clever Control It includes manual or automatic functioning with many different programs depending on heating type (water, electrical, heat pump or unheated) and installed temperature sensors. Clever kit includes: PCB Power Supply Clever Control Outdoor Temperature Sensor - Color TFT screen 2.8 inch - 114 (h) x 85 (w) x 14 (d) mm - Prepared for flush-mount installation - Input: 100-240Vx1 50/60Hz (AC) - Output: 24V 2A (DC) - EU 2 pins / BS 3 pin plugs Intelligent PCB Box RJ11 + RJ45 Cables Door Contact - Easy Plug & Play installation - RJ11 (4 Pins), 7m length - RJ45 (8 Pins), 3m length - Monitoring Door Status - Magnetic contact - Electronic PCB Regulation - 218 (w) x 140 (h) x 64 (d) mm - Varnish Protection SPECIAL CONNECTION - Real-time temperature values - IP65 Protection SPECIAL CONNECTION RJ45 CABLE RJ11 CABLE 8 PINS CONNECTOR 4 PINS CONNECTOR INTELLIGENT PCB BOX OUTDOOR TEMPERATURE SENSOR DOOR CONTACT CLEVER CONTROL PCB POWER SUPPLY 100 - 240Vx1 50/60 Hz AIR CURTAIN SIMPLE INSTALLATION Plug & Play Factory adjusted control to just switch on and run 45 CONTROLLERS AND REGULATION Hand/Auto Control Digital Thermostat For air curtains with water heating. Manual or automatic operating. It permits to program the equipment according to auxiliary sensors: ambient thermostat, door contact, anti-freeze sensor, etc. For air curtains with heating through electrical resistances. Modifies the heating stages and the ventilation speed according to temperature and selected program. It permits the operating with a door contact. Price Euros/Ut. Model CH-5HW-NE CH-2HO-NE 180 180 Clever Control automatically adapts the functioning of the air curtain to the entrance conditions, maintaining comfort while saving energy. It optimizes the ventilation and heating to make an efficient barrier for an optimal climate separation. It allows the connection to a centralised management system like BMS. Price Euros/Ut. 450 158 292 Price Euros/Ut. Model IN-NE-II 89 IR Control Ambient Thermostat Infrared remote controller for all models. (except Minibel) To control the equipment according to the selected temperature. Price Euros/Ut. Model IR CONTROL AIR 46 143 Interface connection BMS CLEVER KIT CLEVER TFT CLEVER PCB + DC TS TD-NE Clever Control Model Model Price Euros/Ut. Model 30 Price Euros/Ut. Model TA-1002 36 External sensor Plug&Play Cable It permits to measure the temperature in a different room that the one that is controlled.It is compatible with digital thermostat TD and Clever Control. Connexion cable between the controller and the air curtain. CB4/7/20/50 of 4, 7, 20 and 50 meters. Price Euros/Ut. 22 Model Price Euros/Ut. CB4 CB7 CB20 CB50 16 20 30 68 CONTROLLERS AND REGULATION Solenoid Valve Modulating Valve It turns ON/OFF the heating by opening or closing the hot water inlet valve to the water coil. The air curtain supplies 230Vx1 to open the valve. It allows the opening of the valve from 0 to 100% to modulate the heating. Regulating the heating proportionally, you can adjust the temperature better while achieving higher energy saving. Price Euros/Ut. Model V-S 3/4" V-S 1" V-S 1-1/4" V-S 1-1/2" 144 223 741 507 Model Price Euros/Ut. V-M consult 3 ways thermostatic valve Anti-freezing sensor It allows a proportional control of the outlet air temperature. It protects the equipment in case of freezing of the water coil. AFS model not mounted, AFS-INS model mounted in the air curtain. Price Euros/Ut. Model V-T DN20 3/4” (and 1/2”) V-T DN25 1" V-T DN40 1-1/2” 334 374 588 Model AFS-5-INS LONG<2000 AFS-1-INS LONG>=2000 AFS-5 (sensor 3m) AFS-1 (sensor 6m) Price Euros/Ut. 206 209 146 146 Door contact To operate the equipment according to the state of the door (open/closed). MAG model, magnetic contact, MEC model mechanical contact. Model DC-MAG DC-MEC Price Euros/Ut. 18 102 47 SUPPORTS Wall Support Vibration Dampers To anchor the air curtains to the wall, for following models: Kool (SPT3), Optima (SPT2) and Minibel (SPT1). It attenuates possible vibrations and avoids the transmission of sound frequencies. Model Price Euros/Ut. SPT1 SPT2 SPT3 12 13 13 SLB-M8 SLB-M10 8 23 Tension Support Angle Support Stainless cable of easy installation with shackle. Threaded end M8/10, of 1 or 5 meters (1M/5M). Other lengths under request. Angle support with silenblock to attenuate possible vibrations and avoid the transmission of sound frequencies. Ideal for recessed units. Price Euros/Ut. Model SPCT-M8 1M SPCT-M8 5M SPCT-M10 1M SPCT-M10 5M 14 22 36 51 Price Euros/Ut. Model SPANG-SIL 2 Universal Simple Support Universal Wall Support VR It allows the hanging installation for any type of air curtains. Available in different lengths, for all models. It allows the hanging installation for any type of air curtains. It incorporates a vertical guide rail to increase the anchor area. Available in different lengths, for all models. Price Euros/Ut. Model SPWR-360 SPWR-400 SPWR-600 SPWR-720 32 31 50 61 SPWR-600 VR SPWR-720 VR SPWR-800 VR SPWR-1040 VR SPF-KOOL SPF-M,ECM,G,ECG,DAM SPF-L,XL SPF-RUND SPF-ZEN SPF-MAX SPF-INVISAIR SPF-MXW SPF-KOOL S/S SPF-M,ECM,G,ECG,DAM S/S SPF-L,XL S/S SPF-RUND S/S SPF-ZEN S/S Price Euros/Ut. 73 73 192 246 323 97 81 97 233 251 343 342 468 70 80 83 166 Installation Kit for 2 Air Curtains pilled up in Vertical To join two units and its anchor to the wall. S/S Models in Stainless Steel. For air curtain vertical mounting. Includes metal pieces for floor anchor. S/S Models in Stainless Steel. Model Price Euros/Ut. Model Feet for Vertical Installation 48 Price Euros/Ut. Model Model SPJ2-KOOL SPJ2-M,ECM,G,ECG,DAM SPJ2-RUND SPJ2-L,XL SPJ2-MAX SPJ2-INV SPJ2-MXW SPJ2-M,ECM,G,ECG,DAM S/S Price Euros/Ut. 62 62 100 178 86 86 86 283 SUPPORTS Rund Angle Support Tailor-made Joinning & Rund Support Rund air curtain anchors for lateral wall or ceiling. They are custom-made (the number indicates the maximum distance between the center of the air curtain and the wall or ceiling). S/S Models in Stainless Steel. To join and support 2 Rund air curtains. They are custom-made (number indicates maximum distance between center of air curtain and wall/ceiling). Thus, it is possible to join several air curtains to obtain all lengths. S/S Models in Stainless Steel. Price Euros/Ut. Model SPANG-RUND-500 SPANG-RUND-1000 SPANG-RUND-1500 SPANG-RUND-500 S/S SPANG-RUND-1000 S/S SPANG-RUND-1500 S/S 531 663 773 754 919 1.079 Price Euros/Ut. Model SPANG-INT-RUND-500 SPANG-INT-RUND-500 S/S 333 675 Arm/Goalpost Rund Tailored Rund Straight Arm Tailor-made Anchorage for the lateral of Rund air curtains to wall, ceiling or floor (goalpost). It is tailor-made (the number indicates the max. length of the arm). S/S Models in Stainless Steel. Rund air curtain anchors for lateral walls. They are tailor-manufactured (the number indicates the maximum distance between the center of the air curtain and the wall). S/S Models in Stainless Steel. Price Euros/Ut. Model SPARM-90-1000 SPARM-90-1500 SPARM-90-2000 SPARM-90-2500 SPARM-90-3000 SPARM-90-3500 SPARM-90-1000 S/S SPARM-90-1500 S/S SPARM-90-2000 S/S SPARM-90-2500 S/S SPARM-90-3000 S/S SPARM-90-3500 S/S 1.236 1.355 1.479 1.603 1.742 1.910 1.343 1.583 1.823 2.063 2.163 2.543 Model SPARM-180-1000 SPARM-180-2000 SPARM-180-1000 S/S SPARM-180-2000 S/S Price Euros/Ut. 699 1.025 849 1.049 Optima Joint To join 2 or more optima air curtains making all lengths possible. Model RNG 20/30 Price Euros/Ut. 15 49