Hay Ansi Bifma X5.4
3480 Windquest Dr. Holland, MI 49424 PH 616-928-0791 FAX 616-928-0792 www.furnituretest.com Test Request Number: AFT-02811 Page 1 of 14 Requester: Orangebox US Inc. 3445 East Paris Ave SE Grand Rapids, MI 49512 Contact Name / Number: Russ Whitaker (616) 285-2545 x10 Dates Tested: 05/12/15 to 06/10/15 Date Submitted: 06/10/15 Technician: Ron Day, Matt Dekock, Dan Baron, Doug Behrendt Customer Request I.D. N/A Scope: To evaluate the Hay Chair, manufactured by Orangebox US Inc., by subjecting it to the following tests: Requested Tests: Test Name Requirement Backrest Strength Test – Horizontal – Static Backrest Strength Test – Vertical – Static Backrest Durability Test – Horizontal – Cyclic Backrest Durability Test – Vertical – Cyclic Arm Strength – Horizontal – Static Arm Strength – Vertical – Static Arm Durability for Single Units – Angular – Cyclic Seating Durability Test – Cyclic Drop Test – Dynamic Unit Drop Test - Dynamic Swivel Test - Cyclic Stability Tests ANSI/BIFMA X5.4-2012, Section 5 ANSI/BIFMA X5.4-2012, Section 6 ANSI/BIFMA X5.4-2012, Section 7 ANSI/BIFMA X5.4-2012, Section 8 ANSI/BIFMA X5.4-2012, Section 9 ANSI/BIFMA X5.4-2012, Section 10 ANSI/BIFMA X5.4-2012, Section 13 ANSI/BIFMA X5.4-2012, Section 14 ANSI/BIFMA X5.4-2012, Section 15 ANSI/BIFMA X5.4-2012, Section 17 ANSI/BIFMA X5.4-2012, Section 19 ANSI/BIFMA X5.4-2012, Section 21 Product Description: Specimen Description Supplier 1 Hay Chair Orangebox US Inc. This report shall not be reproduced, except in full, without written permission from Advanced Furniture Testing, Inc. Results contained within this report only apply to the actual product tested under the testing conditions documented in this report. Test Request Number: AFT-02811 3480 Windquest Dr. Holland, MI 49424 PH 616-928-0791 FAX 616-928-0792 www.furnituretest.com Page 2 of 14 Summary: Test Name Results Backrest Strength Test – Horizontal – Static Backrest Strength Test – Vertical – Static Backrest Durability Test – Horizontal – Cyclic Backrest Durability Test – Vertical – Cyclic Arm Strength – Horizontal – Static Arm Strength – Vertical – Static Arm Durability for Single Units – Angular – Cyclic Seating Durability Test – Cyclic Drop Test – Dynamic Unit Drop Test - Dynamic Swivel Test - Cyclic Stability Tests Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Test Request Number: AFT-02811 3480 Windquest Dr. Holland, MI 49424 PH 616-928-0791 FAX 616-928-0792 www.furnituretest.com Page 3 of 14 Test Results: 1. Backrest Strength Test – Horizontal – Static: Testing was performed per ANSI/BIFMA X5.4-2012, Section 5. Notes: Temperature / humidity 75° F / 56 RH% Load applied 16" up from the seat at the side to side center of the backrest. See Photo 1 for setup. Photo 1 Specimen Load (lbs.) Time (sec.) Observations 1 150 250 60 60 No loss of serviceability. No sudden and major change in structural integrity. Requirement: Functional Load: A functional load applied once shall cause no loss of serviceability to the unit. Proof Load: A proof load applied once shall cause no sudden and major change in the structural integrity of the unit. Loss of serviceability is acceptable. Equipment: Test machine (TM-001.1), CMD (TD-046), Tape measure (TD-094), Digital protractor (TD-059), Stopwatch (TD-010). Test Request Number: AFT-02811 3480 Windquest Dr. Holland, MI 49424 PH 616-928-0791 FAX 616-928-0792 www.furnituretest.com Page 4 of 14 2. Backrest Strength Test – Vertical – Static: Testing was performed per ANSI/BIFMA X5.4-2012, Section 6. Notes: Temperature / humidity 75° F / 56 RH% Load applied over a 16" area centered side to side at the top of the backrest. See Photos 2 (functional load) and 3 (proof load) for setups. Photo 2 Specimen 1 Photo 3 Load (lbs.) Time (sec.) Observations 200 300 60 60 No loss of serviceability. No sudden and major change in structural integrity. Requirement: Functional Load: A functional load applied once shall cause no loss of serviceability to the unit. Proof Load: A proof load applied once shall cause no sudden and major change in the structural integrity of the unit. Loss of serviceability is acceptable. Equipment: Tape measure (TD-094), Stopwatch (TD-010) Test Request Number: AFT-02811 3480 Windquest Dr. Holland, MI 49424 PH 616-928-0791 FAX 616-928-0792 www.furnituretest.com Page 5 of 14 3. Backrest Durability Test – Horizontal – Cyclic: Testing was performed per ANSI/BIFMA X5.4-2012, Section 7. Notes: Temperature / humidity 71 - 76° F / 45 - 59 RH% Load applied at the top of the backrest at the side to side center of the chair. Test rate: 22 cpm. See Photo 4 for setup. Photo 4 Specimen Cycles Observations 1 0 120,000 Test begun. No loss of serviceability. Requirement: There shall be no loss of serviceability. Equipment: Test machine (TM-001.3), CMD (TD-046), Tape measure (TD-094), Digital protractor (TD-059), Stopwatch (TD-010) Test Request Number: AFT-02811 3480 Windquest Dr. Holland, MI 49424 PH 616-928-0791 FAX 616-928-0792 www.furnituretest.com Page 6 of 14 4. Backrest Durability Test – Vertical – Cyclic: Testing was performed per ANSI/BIFMA X5.4-2012, Section 8. Notes: Temperature / humidity 73 - 74° F / 46 - 47 RH% Load applied over a 16" area at the top of the backrest centered side to side. Test rate: 17 cpm. See Photo 5 for setup. Photo 5 Specimen Cycles Observations 1 0 10,000 Test begun. No loss of serviceability. Requirement: There shall be no loss of serviceability. Equipment: Test machine (TM-009), Tape measure (TD-098), Stopwatch (TD-095) 3480 Windquest Dr. Holland, MI 49424 PH 616-928-0791 FAX 616-928-0792 www.furnituretest.com Test Request Number: AFT-02811 Page 7 of 14 5. Arm Strength Test – Horizontal – Static: Testing was performed per ANSI/BIFMA X5.4-2012, Section 9. Notes: Temperature / humidity 75° F / 56 RH% Functional load: 100 lbs. Proof load: 150 lbs. Each load applied in both the inward and outward directions. See Photos 6 and 7 for setups. Photo 6 Specimen 1 Photo 7 Load (lbs.) 100 100 150 150 Direction Time (sec.) Observations Outward Inward Outward Inward 60 60 60 60 No loss of serviceability. No loss of serviceability. No sudden and major change in structural integrity. No sudden and major change in structural integrity. Requirement: Functional Load: A functional load applied once shall cause no loss of serviceability to the unit. Proof Load: A proof load applied once shall cause no sudden and major change in the structural integrity of the unit. Loss of serviceability is acceptable. Equipment: Test machine (TM-001.1), Tape measure (TD-094), Stopwatch (TD-010) Test Request Number: AFT-02811 3480 Windquest Dr. Holland, MI 49424 PH 616-928-0791 FAX 616-928-0792 www.furnituretest.com Page 8 of 14 6. Arm Strength Test – Vertical – Static: Testing was performed per ANSI/BIFMA X5.4-2012, Section 10. Notes: Temperature / Humidity 74° F / 56 RH% Functional load: 169 lbs. Proof load: 253 lbs. Center of 5″ load adapter positioned at the weakest part of the arm. See Photo 8 for setup. Photo 8 Specimen Load (lbs.) Time (sec.) Observations 1 169 253 No loss of serviceability. No sudden and major change in structural integrity. 60 60 Requirement: Functional Load: A functional load applied once shall cause no loss of serviceability to the unit. Proof Load: A proof load applied once shall cause no sudden and major change in the structural integrity of the unit. Loss of serviceability is acceptable. Equipment: Test machine (TM-001.1), Tape measure (TD-094), Stopwatch (TD-010) Test Request Number: AFT-02811 3480 Windquest Dr. Holland, MI 49424 PH 616-928-0791 FAX 616-928-0792 www.furnituretest.com Page 9 of 14 7. Arm Durability for Single Units – Angular- Cyclic: Testing was performed per ANSI/BIFMA X5.4-2012, Section 13. Notes: Temperature / humidity 73 - 75° F / 53 - 60 RH% A 90 lb. load was applied at a 10° angle once per cycle to each arm. Test Rate: 23 cpm. See Photo 9 for setup. Photo 9 Specimen Cycles Observations 1 0 60,000 Test begun. No loss of serviceability. Requirement: There shall be no loss of serviceability to the unit. Equipment: Test machine (TM-022.1, TM-022.2), Tape measure (TD-098), Digital level (TD-073), Stopwatch (TD-095) Test Request Number: AFT-02811 3480 Windquest Dr. Holland, MI 49424 PH 616-928-0791 FAX 616-928-0792 www.furnituretest.com Page 10 of 14 8. Seating Durability Test – Cyclic: Testing was performed per ANSI/BIFMA X5.4-2012, Section 14. Notes: Temperature / humidity 70 - 72° F / 51 - 57 RH% 125 lb. load applied through a 16" bag dropped 1.2" above the seat surface. Impact test rate: 20 cpm. See Photo 10 for setup. Photo 10 Specimen Cycles Observations 1 0 100,000 Begin test. No loss of serviceability. Requirement: There shall be no loss of serviceability to the unit. Equipment: Test machine (TM-003), Tape measure (TD-102), Stopwatch (TD-096) Test Request Number: AFT-02811 3480 Windquest Dr. Holland, MI 49424 PH 616-928-0791 FAX 616-928-0792 www.furnituretest.com Page 11 of 14 9. Drop Test – Dynamic: Testing was performed per ANSI/BIFMA X5.4-2012, Section 15. Notes: Temperature / humidity 74° F / 55 RH% Functional load: 225 lbs. Proof load: 300 lbs. Load dropped from a height of 6" through a 16" diameter bag. See Photo 11 for setup. Photo 11 Specimen Load (lbs.) Observations 1 225 300 No loss of serviceability. No sudden and major change in structural integrity. Requirement: Functional Load: A functional load applied once to each seating position shall cause no loss of serviceability. Proof Load: A proof load applied once to each seating position shall cause no sudden and major change in the structural integrity of the unit. Loss of serviceability is acceptable. Equipment: Tape measure (TD-094), Scale (TD-008) Test Request Number: AFT-02811 3480 Windquest Dr. Holland, MI 49424 PH 616-928-0791 FAX 616-928-0792 www.furnituretest.com Page 12 of 14 10. Unit Drop Test – Dynamic: Testing was performed per ANSI/BIFMA X5.4-2012, Section 17. Notes: Temperature / humidity 73° F / 57 RH%. Unit weight: 31 lbs. Each end of the unit was raised 7.1" and allowed to free-fall to the floor. See Photo 12 for setup. Photo 12 Specimen End Observations 1 Left Side Right Side No loss of serviceability. No loss of serviceability. Requirement: There shall be no loss of serviceability. Equipment: Tape measure (TD-094), Scale (TD-008) Test Request Number: AFT-02811 3480 Windquest Dr. Holland, MI 49424 PH 616-928-0791 FAX 616-928-0792 www.furnituretest.com Page 13 of 14 11. Swivel Test – Cyclic: Testing was performed per ANSI/BIFMA X5.4-2012, Section 19. Notes: Temperature / humidity 70 -75° F / 45 - 58 RH% Seat load: 250 lbs. Seat load location: two inches in front of the centerline of the spindle and centered from left to right. Test rate: 14 cpm. See Photo 13 for setup. Photo 13 Specimen Cycles Observations 1 0 120,000 Test begun. No loss of serviceability. Requirement: There shall be no loss of serviceability. Equipment: Test machine (TM-012), Tape measure (TD-099), Stopwatch (TD-002) Test Request Number: AFT-02811 3480 Windquest Dr. Holland, MI 49424 PH 616-928-0791 FAX 616-928-0792 www.furnituretest.com Page 14 of 14 12. Stability Tests: Testing was performed per ANSI/BIFMA X5.4-2012, Section 21. Notes: Temperature / humidity 74° F / 50 RH% Unit weight: 31 lbs. Front stability load applied at a 45° downward angle at the front edge of the seat surface. Minimum rear stability force calculation: 1.1(47-18.5) = 31.35 lbs. Minimum front stability force calculation: 31 x .40 = 12.4 lbs. See Photo 14 for rear stability setup and Photo 15 for front stability setup. Photo 14 Photo 15 Specimen Stability Force Observations 1 Rear Front 42.6 lbs. 24.5 lbs. The unit did not tip over. The unit did not tip over. Requirement: Rear Stability: Application of the force shall not cause the unit to tip over. Front Stability: The force shall not be less than 40% of the total unit weight. Equipment: Digital level (TD-073), Tape measure (TD-098), Scale (TD-008), Force gage (TD-007) Reviewed by: Dan Baron Approved by: Dan Baron Version 1.0