Test Request Number: AFT-02811
Page 1 of 14
Requester:
Orangebox US Inc.
3445 East Paris Ave SE
Grand Rapids, MI 49512
Contact Name / Number: Russ Whitaker (616) 285-2545 x10
Dates Tested:
05/12/15 to 06/10/15
Date Submitted:
06/10/15
Technician:
Ron Day, Matt Dekock, Dan Baron, Doug Behrendt
Customer Request I.D.
N/A
Scope: To evaluate the Hay Chair, manufactured by Orangebox US Inc., by subjecting it to the
following tests:
Requested Tests:
Test Name
Requirement
Backrest Strength Test – Horizontal – Static
Backrest Strength Test – Vertical – Static
Backrest Durability Test – Horizontal – Cyclic
Backrest Durability Test – Vertical – Cyclic
Arm Strength – Horizontal – Static
Arm Strength – Vertical – Static
Arm Durability for Single Units – Angular – Cyclic
Seating Durability Test – Cyclic
Drop Test – Dynamic
Unit Drop Test - Dynamic
Swivel Test - Cyclic
Stability Tests
ANSI/BIFMA X5.4-2012, Section 5
ANSI/BIFMA X5.4-2012, Section 6
ANSI/BIFMA X5.4-2012, Section 7
ANSI/BIFMA X5.4-2012, Section 8
ANSI/BIFMA X5.4-2012, Section 9
ANSI/BIFMA X5.4-2012, Section 10
ANSI/BIFMA X5.4-2012, Section 13
ANSI/BIFMA X5.4-2012, Section 14
ANSI/BIFMA X5.4-2012, Section 15
ANSI/BIFMA X5.4-2012, Section 17
ANSI/BIFMA X5.4-2012, Section 19
ANSI/BIFMA X5.4-2012, Section 21
Product Description:
Specimen
Description
Supplier
1
Hay Chair
Orangebox US Inc.
This report shall not be reproduced, except in full, without written permission from Advanced
Furniture Testing, Inc. Results contained within this report only apply to the actual product tested
under the testing conditions documented in this report.
Test Request Number: AFT-02811
3480 Windquest Dr.
Holland, MI 49424
PH 616-928-0791
FAX 616-928-0792
www.furnituretest.com
Page 2 of 14
Summary:
Test Name
Results
Backrest Strength Test – Horizontal – Static
Backrest Strength Test – Vertical – Static
Backrest Durability Test – Horizontal – Cyclic
Backrest Durability Test – Vertical – Cyclic
Arm Strength – Horizontal – Static
Arm Strength – Vertical – Static
Arm Durability for Single Units – Angular – Cyclic
Seating Durability Test – Cyclic
Drop Test – Dynamic
Unit Drop Test - Dynamic
Swivel Test - Cyclic
Stability Tests
Passed
Passed
Passed
Passed
Passed
Passed
Passed
Passed
Passed
Passed
Passed
Passed
Test Request Number: AFT-02811
3480 Windquest Dr.
Holland, MI 49424
PH 616-928-0791
FAX 616-928-0792
www.furnituretest.com
Page 3 of 14
Test Results:
1. Backrest Strength Test – Horizontal – Static:
Testing was performed per ANSI/BIFMA X5.4-2012, Section 5.
Notes:



Temperature / humidity 75° F / 56 RH%
Load applied 16" up from the seat at the side to side center of the backrest.
See Photo 1 for setup.
Photo 1
Specimen
Load (lbs.)
Time (sec.)
Observations
1
150
250
60
60
No loss of serviceability.
No sudden and major change in structural integrity.
Requirement:
Functional Load: A functional load applied once shall cause no loss of serviceability to the
unit.
Proof Load: A proof load applied once shall cause no sudden and major change in the
structural integrity of the unit. Loss of serviceability is acceptable.
Equipment: Test machine (TM-001.1), CMD (TD-046), Tape measure (TD-094),
Digital protractor (TD-059), Stopwatch (TD-010).
Test Request Number: AFT-02811
3480 Windquest Dr.
Holland, MI 49424
PH 616-928-0791
FAX 616-928-0792
www.furnituretest.com
Page 4 of 14
2. Backrest Strength Test – Vertical – Static:
Testing was performed per ANSI/BIFMA X5.4-2012, Section 6.
Notes:



Temperature / humidity 75° F / 56 RH%
Load applied over a 16" area centered side to side at the top of the backrest.
See Photos 2 (functional load) and 3 (proof load) for setups.
Photo 2
Specimen
1
Photo 3
Load
(lbs.)
Time
(sec.)
Observations
200
300
60
60
No loss of serviceability.
No sudden and major change in structural integrity.
Requirement:
Functional Load: A functional load applied once shall cause no loss of serviceability to the
unit.
Proof Load: A proof load applied once shall cause no sudden and major change in the
structural integrity of the unit. Loss of serviceability is acceptable.
Equipment: Tape measure (TD-094), Stopwatch (TD-010)
Test Request Number: AFT-02811
3480 Windquest Dr.
Holland, MI 49424
PH 616-928-0791
FAX 616-928-0792
www.furnituretest.com
Page 5 of 14
3. Backrest Durability Test – Horizontal – Cyclic:
Testing was performed per ANSI/BIFMA X5.4-2012, Section 7.
Notes:




Temperature / humidity 71 - 76° F / 45 - 59 RH%
Load applied at the top of the backrest at the side to side center of the chair.
Test rate: 22 cpm.
See Photo 4 for setup.
Photo 4
Specimen
Cycles
Observations
1
0
120,000
Test begun.
No loss of serviceability.
Requirement: There shall be no loss of serviceability.
Equipment:
Test machine (TM-001.3), CMD (TD-046), Tape measure (TD-094),
Digital protractor (TD-059), Stopwatch (TD-010)
Test Request Number: AFT-02811
3480 Windquest Dr.
Holland, MI 49424
PH 616-928-0791
FAX 616-928-0792
www.furnituretest.com
Page 6 of 14
4. Backrest Durability Test – Vertical – Cyclic:
Testing was performed per ANSI/BIFMA X5.4-2012, Section 8.
Notes:




Temperature / humidity 73 - 74° F / 46 - 47 RH%
Load applied over a 16" area at the top of the backrest centered side to side.
Test rate: 17 cpm.
See Photo 5 for setup.
Photo 5
Specimen
Cycles
Observations
1
0
10,000
Test begun.
No loss of serviceability.
Requirement: There shall be no loss of serviceability.
Equipment: Test machine (TM-009), Tape measure (TD-098), Stopwatch (TD-095)
3480 Windquest Dr.
Holland, MI 49424
PH 616-928-0791
FAX 616-928-0792
www.furnituretest.com
Test Request Number: AFT-02811
Page 7 of 14
5. Arm Strength Test – Horizontal – Static:
Testing was performed per ANSI/BIFMA X5.4-2012, Section 9.
Notes:





Temperature / humidity 75° F / 56 RH%
Functional load: 100 lbs.
Proof load: 150 lbs.
Each load applied in both the inward and outward directions.
See Photos 6 and 7 for setups.
Photo 6
Specimen
1
Photo 7
Load
(lbs.)
100
100
150
150
Direction
Time
(sec.)
Observations
Outward
Inward
Outward
Inward
60
60
60
60
No loss of serviceability.
No loss of serviceability.
No sudden and major change in structural integrity.
No sudden and major change in structural integrity.
Requirement:
Functional Load: A functional load applied once shall cause no loss of serviceability to the
unit.
Proof Load: A proof load applied once shall cause no sudden and major change in the
structural integrity of the unit. Loss of serviceability is acceptable.
Equipment: Test machine (TM-001.1), Tape measure (TD-094), Stopwatch (TD-010)
Test Request Number: AFT-02811
3480 Windquest Dr.
Holland, MI 49424
PH 616-928-0791
FAX 616-928-0792
www.furnituretest.com
Page 8 of 14
6. Arm Strength Test – Vertical – Static:
Testing was performed per ANSI/BIFMA X5.4-2012, Section 10.
Notes:





Temperature / Humidity 74° F / 56 RH%
Functional load: 169 lbs.
Proof load: 253 lbs.
Center of 5″ load adapter positioned at the weakest part of the arm.
See Photo 8 for setup.
Photo 8
Specimen
Load (lbs.) Time (sec.)
Observations
1
169
253
No loss of serviceability.
No sudden and major change in structural integrity.
60
60
Requirement:
Functional Load: A functional load applied once shall cause no loss of serviceability to the
unit.
Proof Load: A proof load applied once shall cause no sudden and major change in the
structural integrity of the unit. Loss of serviceability is acceptable.
Equipment: Test machine (TM-001.1), Tape measure (TD-094), Stopwatch (TD-010)
Test Request Number: AFT-02811
3480 Windquest Dr.
Holland, MI 49424
PH 616-928-0791
FAX 616-928-0792
www.furnituretest.com
Page 9 of 14
7. Arm Durability for Single Units – Angular- Cyclic:
Testing was performed per ANSI/BIFMA X5.4-2012, Section 13.
Notes:




Temperature / humidity 73 - 75° F / 53 - 60 RH%
A 90 lb. load was applied at a 10° angle once per cycle to each arm.
Test Rate: 23 cpm.
See Photo 9 for setup.
Photo 9
Specimen
Cycles
Observations
1
0
60,000
Test begun.
No loss of serviceability.
Requirement: There shall be no loss of serviceability to the unit.
Equipment:
Test machine (TM-022.1, TM-022.2), Tape measure (TD-098),
Digital level (TD-073), Stopwatch (TD-095)
Test Request Number: AFT-02811
3480 Windquest Dr.
Holland, MI 49424
PH 616-928-0791
FAX 616-928-0792
www.furnituretest.com
Page 10 of 14
8. Seating Durability Test – Cyclic:
Testing was performed per ANSI/BIFMA X5.4-2012, Section 14.
Notes:




Temperature / humidity 70 - 72° F / 51 - 57 RH%
125 lb. load applied through a 16" bag dropped 1.2" above the seat surface.
Impact test rate: 20 cpm.
See Photo 10 for setup.
Photo 10
Specimen
Cycles
Observations
1
0
100,000
Begin test.
No loss of serviceability.
Requirement: There shall be no loss of serviceability to the unit.
Equipment: Test machine (TM-003), Tape measure (TD-102), Stopwatch (TD-096)
Test Request Number: AFT-02811
3480 Windquest Dr.
Holland, MI 49424
PH 616-928-0791
FAX 616-928-0792
www.furnituretest.com
Page 11 of 14
9. Drop Test – Dynamic:
Testing was performed per ANSI/BIFMA X5.4-2012, Section 15.
Notes:





Temperature / humidity 74° F / 55 RH%
Functional load: 225 lbs.
Proof load: 300 lbs.
Load dropped from a height of 6" through a 16" diameter bag.
See Photo 11 for setup.
Photo 11
Specimen
Load (lbs.)
Observations
1
225
300
No loss of serviceability.
No sudden and major change in structural integrity.
Requirement:
Functional Load: A functional load applied once to each seating position shall cause no loss of
serviceability.
Proof Load: A proof load applied once to each seating position shall cause no sudden and major
change in the structural integrity of the unit. Loss of serviceability is acceptable.
Equipment: Tape measure (TD-094), Scale (TD-008)
Test Request Number: AFT-02811
3480 Windquest Dr.
Holland, MI 49424
PH 616-928-0791
FAX 616-928-0792
www.furnituretest.com
Page 12 of 14
10. Unit Drop Test – Dynamic:
Testing was performed per ANSI/BIFMA X5.4-2012, Section 17.
Notes:




Temperature / humidity 73° F / 57 RH%.
Unit weight: 31 lbs.
Each end of the unit was raised 7.1" and allowed to free-fall to the floor.
See Photo 12 for setup.
Photo 12
Specimen
End
Observations
1
Left Side
Right Side
No loss of serviceability.
No loss of serviceability.
Requirement:
There shall be no loss of serviceability.
Equipment:
Tape measure (TD-094), Scale (TD-008)
Test Request Number: AFT-02811
3480 Windquest Dr.
Holland, MI 49424
PH 616-928-0791
FAX 616-928-0792
www.furnituretest.com
Page 13 of 14
11. Swivel Test – Cyclic:
Testing was performed per ANSI/BIFMA X5.4-2012, Section 19.
Notes:





Temperature / humidity 70 -75° F / 45 - 58 RH%
Seat load: 250 lbs.
Seat load location: two inches in front of the centerline of the spindle and centered from
left to right.
Test rate: 14 cpm.
See Photo 13 for setup.
Photo 13
Specimen
Cycles
Observations
1
0
120,000
Test begun.
No loss of serviceability.
Requirement: There shall be no loss of serviceability.
Equipment: Test machine (TM-012), Tape measure (TD-099), Stopwatch (TD-002)
Test Request Number: AFT-02811
3480 Windquest Dr.
Holland, MI 49424
PH 616-928-0791
FAX 616-928-0792
www.furnituretest.com
Page 14 of 14
12. Stability Tests:
Testing was performed per ANSI/BIFMA X5.4-2012, Section 21.
Notes:






Temperature / humidity 74° F / 50 RH%
Unit weight: 31 lbs.
Front stability load applied at a 45° downward angle at the front edge of the seat surface.
Minimum rear stability force calculation: 1.1(47-18.5) = 31.35 lbs.
Minimum front stability force calculation: 31 x .40 = 12.4 lbs.
See Photo 14 for rear stability setup and Photo 15 for front stability setup.
Photo 14
Photo 15
Specimen
Stability
Force
Observations
1
Rear
Front
42.6 lbs.
24.5 lbs.
The unit did not tip over.
The unit did not tip over.
Requirement:
Rear Stability: Application of the force shall not cause the unit to tip over.
Front Stability: The force shall not be less than 40% of the total unit weight.
Equipment: Digital level (TD-073), Tape measure (TD-098), Scale (TD-008),
Force gage (TD-007)
Reviewed by: Dan Baron
Approved by: Dan Baron
Version 1.0