85usp008 (Regency Park PUD) Page 1 of 9 Uniform Sign Plan (USP
Transcription
85usp008 (Regency Park PUD) Page 1 of 9 Uniform Sign Plan (USP
Uniform Sign Plan (USP) Regency Park Planned Unit Development (PUD) 85-USP-008 A sign permit application must be submitted and a permit issued prior to installation of a sign. USP Number: Location: USP established: Modified: 85-USP-008 Along Regency Pky. Ederlee Dr.; south of Tryon Rd. Oct. 10, 1985 Aug. 9, 2004 October 25, 2012 (To allow internally illuminated wall signs in addition to back-lit letters) August 25, 2013 (Criteria established for 12040 Regency Parkway) May 9, 2016 (Grammatical corrections & removed traffic markings and references to sign content) General Provisions This USP includes both the residential and non-residential portions of the Regency Park PDD. A sign may be erected, placed, established, painted, created or maintained in the Town of Cary only in conformance with standards, procedures, exemptions and other requirements of the Town's Sign Ordinance and/or any applicable Uniform Sign Plan (USP) for the property where the sign is located. In situations where the specifications of a previously approved USP conflict with the currently adopted Sign Ordinance provisions, then the specifications in the approved USP shall control. Where a previously approved USP does not contain specific specifications on signage attributes, including but not limited to height, colors, placement, etc., then provisions in the currently adopted Sign Ordinance shall control. Further, a previously approved USP which lacks specific signage attribute specifications, including but not limited to height, colors, placement, etc. may not be amended to include such specifications unless such amendment is in accord with the currently adopted Sign Ordinance. A USP may be amended by filing a new sign plan with the Planning Department. Any new or amended USP, including those for planned unit developments, shall include a schedule for bringing all signs not conforming to the proposed plan into conformance within 90 days. This shall apply to all properties governed by said plan. Residential Neighborhoods: Entry Monuments Quantity & Location Two (2) – At subdivision entrances Materials & Colors Brass or brass-colored letters on brick monument Size: Per LDO Illumination: External ground lights Photo(s): * 85usp008 (Regency Park PUD) Page 1 of 9 Residential: Quantity: Location: Materials: Size: Colors: Illumination Photos: Entry Monuments/Principal Ground Signs (Option) Per Land Development Ordinance At entrance to different major residential developments Metal plaque on brick sign structure or masonry sign panel within a brick framework Per LDO Dark bronze background with light bronze text or dark metal text External Non-residential Ground Signs - Project Identification Quantity: Two (2) Location: At entrances to the project Materials: Molded fiber reinforced polyester (F.R.P) with translucent integral graphics on both faces Size: 4 feet 2 inches (4’2”) high X 12 feet wide Total sign height – 6 feet 5 inches (6’5”) Colors: Background – dark bronze Letters and logo - white Illumination: External flood lights Other: none 85usp008 (Regency Park PUD) Page 2 of 9 Non-residential Ground Signs - Project Identification Photo(s): * Non-residential Ground Signs - Site/Parcel/Subdivision Identification Quantity: Not to exceed two (2) per site Location: At primary entrances to individual sites Materials: Molded fiber reinforced polyester (F.R.P) with translucent integral graphics on both faces Size: Maximum Height 4 feet 8 inches Maximum Width: 6 feet Colors: Background: Dark bronze Letters: White Illumination: External illumination Non-residential Ground Signs – Other (Secondary Site Identification) Quantity: Not specified Location: At non-primary entrance points to individual sites. Materials: Molded fiber reinforced polyester (F.R.P) with translucent integral graphics on both faces 85usp008 (Regency Park PUD) Page 3 of 9 Non-residential Ground Signs – Other (Secondary Site Identification) Size: 3 feet high X 5 feet wide Total sign height – 4 feet Colors: Background: dark bronze Letters: white Illumination: Exterior flood lights Photo(s): * Non-residential Ground Signs – Tenant Directory Quantity: One (1) per building Location: On the subject property – per LDO Materials: Metal with vinyl text Size: 24 inches high X 42 inches wide Total sign height – 30 inches Colors: Not specified Illumination: Exterior flood lights Other: Generally commercial uses only. Function is to identify the location of a specific use within the site for the purpose of directing vehicular traffic. 85usp008 (Regency Park PUD) Page 4 of 9 Non-residential Ground Signs – Tenant Directory . Photo(s): * Non-residential Ground Signs – Other (Major Directional) Quantity: Four (4) Location: At points of diverging vehicular traffic and multiple site access. Materials: Column-like structure (3 feet wide on 4 sides), with directional graphics on as many sides as required Material shall be molded fiber reinforced polyester (F.R.P) OR pre-cast architectural concrete Reflective graphics Size: 12 feet 6 inches (12’6”) high X 3 feet wide Letter height: 6 inches Colors: Background: dark bronze Letters: white reflective Illumination: Exterior flood lights Other: Regency Park name and logo appear on all 4 faces on the top 3 feet of the sign. Primary purpose is to provide direction for vehicular traffic to a specific site within the park. 85usp008 (Regency Park PUD) Page 5 of 9 Non-residential Ground Signs – Other (Major Directional) Photo(s): * Non-residential Ground Signs – Detailed Directory Signs for Site Identification Quantity: Not specified Location: Not specified Materials: Column-like sign structure (3 feet wide on 4 sides), with directional graphics on as many sides as required Similar to the “Major Directional Sign” – to match appearance of “molded fiber reinforced polyester (F.R.P) OR pre-cast architectural concrete” used for major directory signs. Reflective graphics Size: 9 feet 6 inches (9’6”) high X 3 feet wide Letter height – 6 inches Colors: Background: dark bronze Letters: white reflective Illumination: External flood lights Photo(s): * 85usp008 (Regency Park PUD) Page 6 of 9 Non-residential Wall Signs - Tenant Type 1 (Primary Building Signage) Quantity: Maximum 2 per building Location: To identify the building from significant access routes Materials: Fabricated aluminum logo and letters mounted to wall of building, with pigmented polyurethane face Size: Maximum Area: 1.5 sq. ft. per linear foot of building frontage Letter depth: 4 inches Colors: Face: White, dark or light bronze Registered Logos allowed at 20% of allowed sign area Illumination: Backlighting of building face or Internally illuminated channel letters Other: Shall be readable from the serving street and shall consist of numerals, logos, letters, or a combination thereof, that identify the building. Photo Examples Non-residential Wall Signs - Tenant Type 2 (For Ground-level commercial or retail tenants) Quantity: Two (2) per retail use Location: Affixed to building at ground-level floor. In instances where, due to topography or landscaping, visibility of the first floor signage would be prevented, such signage may be located at the second floor level. 85usp008 (Regency Park PUD) Page 7 of 9 Materials: Size: Colors: Illumination: Photo(s): * 3/8 inch thick aluminum plate letters attached to building wall or channel letters Maximum Area: 1.5 square feet per linear foot of storefront Face: white Returns: Dark Bronze or white Backlighting, internally illuminated channel letters, or non-illuminated Non-residential Wall Signs – For 12040 Regency Parkway ONLY Quantity: Maximum 2 per building Location: On front/eastern elevation; affixed in the upper left hand corner; on the rear/northern elevation sign to be fixed in upper right hand corner Materials: 4 inch thick aluminum channel letters Size: Not specified Colors: Face: white, bronze, cool gray PMS 11C, or orange PMS 166c Illumination: Reverse halo lit with internal LEDs Other: Use of cool gray PMS 11c & Orange 166c limited to this site ONLY Non-residential Wall Signs – Outparcels (excludes 12040 Regency Parkway) Quantity & Location Per LDO Materials/Illumination Internally illuminated Metal Channel Letters; Plexiglas faces Size: Per LDO Colors: White faces Bronze Returns 85usp008 (Regency Park PUD) Page 8 of 9 Non-residential Wall Signs – Outparcels (excludes 12040 Regency Parkway) Photo(s): * Non-residential Wall Signs – Other (Multi-tenant office building with multiple entrances) Quantity: Per LDO Location: On individual storefronts Materials: Metal or PVC Size: Maximum or 1.5 sq. ft. per linear foot of storefront area Colors: White or dark bronze Illumination: Subject to property management authorization Photos: * Note: photos and diagrams are for illustrative purpose, and do not represent every sign on the property. 85usp008 (Regency Park PUD) Page 9 of 9