CATALOG No. E4221-218 ® CONTRACER Contour Measuring Instruments That's digital! All models feature a Z-axis with integrated digital-scale detecting unit. Mitutoyo's Contracer CV Series is a high-accuracy contour measuring instrument with a digital scale on the X- and Z-axis. Digitization of the Z-axis gives you the following: • No need to calibrate the Z-axis according to measurement magnification • No need to change the Z-axis detection zone according to measurement magnification • High-accuracy measurement for large-displacement contours That's Mitutoyo! A wide selection of models designed to make measuring easier, more comfortable and more accurate! Outstanding measurement support, thanks to Windows OS-compatible "FORMPAK -1000" Contour Analysis ® ® Windows®95/Windows®98/Windows®NT4.0/Windows®2000 is used as the OS. Program commands can be accessed via icons and a powerful Help function, making it easy for anyone to use . . . even a novice! 2 CV-2000M4 CV-H628 X-axis/Z-axis measuring range: 200mm (8")/25mm (1") Vertical travel: 250mm (10") Base size (WxD): 600x450mm (24"x18") X-axis/Z-axis measuring range: 100mm (4")/40mm (1.5") Vertical travel: 320mm (13") Base size (WxD): 600x450mm (24"x18") CV-1000N2 X-axis/Z-axis measuring range: 50mm (2")/25mm (1") Vertical travel: — Base size (WxD): — CV-3000S4 /4000S4 X-axis/Z-axis measuring range: 100mm (4")/50mm (2") Vertical travel: 250mm (10") Base size (WxD): 610x450mm (24"x18") CV-3000W8 /4000W8 X-axis/Z-axis measur ing range: 200mm (8")/50mm (2") Vertical travel: 450mm (18") Base size (WxD): 1000x450mm (40"x18") CV-3000H4 /4000H4 X-axis/Z-axis measuring range: 100mm (4")/50mm (2") Vertical travel: 450mm (18") Base size (WxD): 610x450mm (24"x18") CV-3000H8 /4000H8 CV-3000W4 /4000W4 X-axis/Z-axis measuring range: 100mm (4")/50mm (2") Vertical travel: 450mm (18") Base size (WxD): 1000x450mm (40"x18") CV-3000S8 /4000S8 X-axis/Z-axis measuring range: 200mm (8")/50mm (2") Vertical travel: 250mm (10") Base size (WxD): 610x450mm (24"x18") X-axis/Z-axis measuring range: 200mm (8")/50mm (2") Vertical travel: 450mm (18") Base size (WxD): 610x450mm (24"x18") Mitutoyo offers a range of models for every requirement. There's sure to be one that fits your needs! Contracer CV Series 3 Contracer Equipped the X- and Z-axis with Laser Holoscale Small-footprint design . . . smart, simple operation! Mitutoyo's holographic scale, which is based on the interference phenomenon of diffracted light, is incorporated into the detector as a measuring unit for the X- and Z-axes. The Laser Holoscale offers the world's highest level of resolution along the X-axis 0.00625µm (.25µinch), Z-axis 0.0125µm (.5µinch) over the entire measurement range of the X-axis at 200 mm (8"), and the Z-axis 25 mm (1"). The electronic unit is housed within the measuring unit's vibration isolator, and the vertical side table is a standard configuration that houses the data analysis unit. Principale of Laser Holoscale Detector Laser beam Beam splitter [b] [a] Mirror Mirror Scale Mirror Mirror Beam splitter Laser diode Laser Holoscale 4 Interference fringe Glass plate 0.5µm (.02µinch) World-class resolution and accuracy (Z-axis) Photo: CV-H628 with personal computer system FORMPAK®-1000 software is easy to operate, and capable of powerful analysis, concurrently. Contracer CV Series 5 Contracer Featuring a digital scale unit installed in the Z-axis detection unit (CV-3000 Series) Ceramic guides have been employed for abrasion resistance. The CV-3000 Series, which uses a digital scale unit in its Z-axis detection unit, achieves a resolution of 0.0002 mm (.000008") at a full stroke of ±25 mm (±1"). And unlike conventional, differential transformer units, there is no change in resolution as the range of magnification changes. The result: a dramatic improvement in operation and performance! Photo: CV-3000S4 with personal computer system 6 Contracer A dedicated control box for ease of operation. • The control box, which is independent of the main unit, gives you remote control over positioning, measurement start/stop, returning, and other key operations. • The drive unit's up/down position and the X-axis traverse can be fine-tuned under manual control. Mitutoyo’s Holographic Scale delivers super-high accuracy (CV-4000 Series) • The new, top-of-the-line Holography Scale is based on the interference phenomenon of diffracted light, ensuring the absolute in accuracy. It allows dimensional measurement at a resolution of 0.00005mm (.000002") over the entire measurement range of 50mm (2"). Photo: CV-4000S4 with personal computer system FORMPAK®-1000 software is easy to operate, and capable of powerful analysis, concurrently. Contracer CV Series 7 Contracer Mitutoyo digitizes the X- and Z-axes over the full range, giving you a wider range of measurement with higher resolution. No more reliance on measurement magnifications! • CV-1000N2 can be attached to the optical stand. The CV-1000 is portable and can be carried to the machine-shop for measurement of large workpieces. Even at a site where a power source may not be nearby, the CV-1000 can work with the optional display unit (built-in rechargeable battery). Display unit and XY plotter Icons and graphics on the LCD and touch panel make it easy for anyone—even a novice—to perform key analysis operations. The contour profile can be confirmed with the display unit prior to output to an XY plotter. Contour measurement data can be stored on optional RAM cards and read into the personal computer. 8 Contracer Arc Scale on the Z-axis Light emission device Connected to a personal computer, the FORMPAK-1000 contour analysis program provides various modes of measurement and analysis. When connected to an XY plotter, the contour profile can be checked with the display unit prior to output. Arc scale Receiver IC *The following plotters are recommened •MP5100-51 (Graphtec) •Y-1x50 (DXY-1150, 1250, 1350) (Roland) Photo: CV-2000M4 with personal computer system FORMPAK®-1000 software is easy to operate, and capable of powerful analysis, concurrently. Contracer CV Series 9 FORMPAK-1000 is a powerful program that has an enhanced user interface, including mouse operation, a variety of graphic displays, and online help which is convenient if the user experiences a problem. In addition to being able to perform dimensional measurements such as angle, radius, and distance measurements, the contour tolerancing function for evaluating "form" and the report creation function for outputting measurement results in a specific format are provided as standard, ensuring both ease of operation and powerful analysis capabilities. Realtime Measurement window Analysis Result window Online help function The appropriate help window displaying operating procedures, the definition of icons, etc., can be opened as required. This function eliminates the need to find information in the manual. Report creation function Geometric measured data, measurement conditions, contour tolerancing results, and comments can be laid out as desired and printed out in a report. Once a layout has been saved, it can be reused as a glossary if the same measurement is made. A report can be printed in A3 size or from a color printer (option). Layout Edit window User customization function The size and position of operation buttons on a window can be modified as desired. This function allows the counter display, each window, the location of analysis command buttons, or the display color of measured data and auxiliary lines to be modified. External output function Calculation results and tolerancing results can be downloaded in a readable format to commercial spreadsheet software. This function increases processing capabilities including statistical calculation, saving, and management of measurement results. It also allows measured point group data to be output in the text format. 10 Printout examples Contour tolerancing function This function compares measured data as "form" with nominal data, displays the deviation, and then stores it, being different from dimensional measurement of angle, radius, etc. In addition to values obtained from an ideal contour in a CAD drawing, nominal values can be created by converting the measured data of a master. Contour tolerancing flow Measured data • Creation by the function • Conversion from the master measured data • Inputting from CAD Tolerancing Tolerancing Best-fit processing Developed Error Display window Tolerancing calculation Tolerancing Result window Tolerancing results display Specifications Operation commands 1. Point measurement: Point, peak, contact, intersection, bisector-point (between elements/ pieces of measured data) 2. Line measurement: Line, tangent line, perpendicular, parallel line, bisector 3. Circle measurement: Circle (multi-points, range, center and radius) 4. Position, difference: Coordinate difference, true position judgment 5. Distance, angle: Distance, groove length, step, pitch, distance reference, angle 6. Coordinate system setup: Origin setup, coordinate system rotation 7. Calculation, statistics: Arithmetic calculation, absolute value, square root, maximum value, minimum value, mean, sum, standard deviation, unbiased standard deviation, area 8. Editing of measured points: Deletion, translation, rotation, mirror image, positioning, combination, separation, projection Contour tolerancing 1. Nominal value data creation • Function specification (line/circle/aspheric surface, etc.), CAD input (IGES, DXF), measured data conversion, text file conversion • Tolerancing direction setup (normal direction/Xaxis direction/Z-axis direction) 2. Reference coordinate system translation/rotation 3. Best-fit • X-axis translation, Z-axis translation, rotating direction, several kinds in combination 4. Nominal value tolerancing 5. Results display • Result list display, graphic display Special functions a. Sub-part program: Calculation procedure can be registered as a Sub-part program. The Sub-part program can be integrated into a part program facilitating measurement of batch of workpieces. b. Measured data/conditions saving: Measured data and analysis procedure can be saved in the hard disk. c. Layout Edit function: A measured profile, measurement conditions, etc., can be arranged in a form and laid out as desired. This function allows an original result report to be created and printed out. d. External output of files: Analysis results can be output in the CSV format, and therefore, can be easily accessed by commercial spreadsheet software. Also, measured data (point group data) can be output in the ASCII code. e. Part program: Measurement procedures complete with measurement, analysis, contour tolerance judgment, print, and save as a file, can be registered as a part program. The part program can be executed for automatic measurements. f. Polar coordinate development display: Develops a circular form on to the polar coordinate system, where the range for circle calculation can be specified. Contracer CV Series 11 Rugged tables Rotary vises Rotary table Holder with clamp Cross-travel table Rotary vise Rotary table Holder with clamp • Table top: 280x180mm (11"x7") • XY travel: 100x50mm (4"x2") • Two-slide jaw type. • Max. workpiece size: ø60mm (2.4") • Minimum reading: 1° • Table top: ø146mm (5.7" DIA) • Minimum reading: 2' • Holder with clamp (176107) can be mounted. • Used with a cross-travel table or rugged table. • Max. workpiece height: 35mm (1.3") 176-107 218-001 (mm) 218-011 (inch) 218-003 Cross-travel table Rotary vise • Table top: 280x152mm (11"x6") • XY travel: 50x25mm (2"x1") • One-slide jaw type. • Max. workpiece size: ø60mm (2.4") • Minimum reading: 5° Center supports 172-196 Swivel center support Leveling tables XY leveling table with swivel • Table top: 130x100mm (5"x4") • Leveling range: ±1.5° • XY travel: ±12.5mm (±.5") 218-041 (mm) 218-051 (inch) 172-144 178-043-1 (mm) 178-053-1 (inch) Rugged table • Table top: 280x180mm (11"x7") • Provided with T-grooves for mounting workpiece fixtures. V-blocks • Max. workpiece diameter: 80mm (3.1")* *65mm (2.5") when swiveled 10° • Max. workpiece length: 140mm (5.5") 172-197 Center support • Max. workpiece diameter: 120mm (4.7") • 60mm (2.3") rizer is optional (172-143). V-block with clamp • Used with a cross-travel table or rugged table. • Max. workpiece diameter: 50mm (2") 218-002 Digimatic XY leveling table with swivel • Table top: 130x100mm (5"x4") • Leveling range: ±1.5° • XY travel: ±12.5mm (±.5") 172-142 Center support riser • Used with a center support. • Max. workpiece diameter: 240mm (9.4") 172-234 V-block with clamp Vibration isolator Vibration isolator • Dimensions (WxDxH): 750x550x59mm (30"x22"x2.3") • Stand is optional (178-024). • Used with a cross-travel table or rugged table. • Max. workpiece diameter: 25mm (1") 172-143 178-042-1 (mm) 178-052-1 (inch/mm) Leveling table • Table top: 130x100mm (5"x4") • Leveling range: ±1.5° • Height: 40mm (1.57") Vise Precision vise • Max. workpiece size: 36mm (1.42") • Can be mounted on a leveling table. 172-378 178-016 178-023 12 178-019 System diagram 172-196 218-003 172-144 176-107 172-234 172-378 172-142 172-197 172-143 Optional arms (See page 14) Optional styli (See page 15) 218-041 (mm) 218-051 (inch) 218-001 (mm) 218-011 (inch) 218-002 178-047 178-016 CV Series main unit and standard accessories CV-H628 CV-3000/4000 CV-1000/2000 218-010 218-008 178-043-1 178-053-1 178-042-1 178-052-1 218-007 178-023 218-024 (CV-1000 only) 211-016 997996 178-019 998291 V-block 166-215 Symmetry calibration gages V-block • Workpiece diameter: 1mm to 160mm (.04" to 6.3") • Can be mounted on a leveling table. Others CV-H628 Used to calibrate a slight circular error due to attachment errors of the stylus and arm. These gages are usually required to perform high-accuracy measurement of a lens, etc. Windshield cover Symmetry calibration gage (angle measurement type) Display unit Symmetry calibration gage (sphere measurement type) 12AAC168 CV-1000/2000 218-341■ ■ Suffix: A for 120V, D for 220V, E for 240V or non for 100V RAM card 12AAA841 997996 998291 Pin gage unit (CV-1000/2000) 211-016 Measuring stand (CV-1000) 218-024 998862 (mm) 998861 (inch) Contracer CV Series 13 — ARMS — For CV-3000/4000 Eccentric type Stylus 185 ") (7.28 15 (.59") 185 ") (7.28 Stylus (1. 996504 for 6mm (.24") high stylus 996505 for 12mm (.47") high stylus 996506* for 20mm (.79") high stylus 996507 for 30mm (1.18") high stylus 996508 for 42mm (1.65") high stylus Unit: mm (inch) 996509 996510 996511 996512 996513 40 57 ø3 (.12") ø8 (.31") ø8 (.31") Unit: mm (inch) For small hole stylus 15 (.59") Stylus 130 ") (5.12 15 (.59") ") for 6mm (.24") high stylus for 12mm (.47") high stylus for 20mm (.79") high stylus for 30mm (1.18") high stylus for 42mm (1.65") high stylus Unit: mm (inch) ø8 (.31") Straight type 15 (.59") 996514 *Standard accessory For CV-1000/2000 155 ") (6.10 15 (.59") 935111 for 6mm (.24") high stylus 935112 for 12mm (.47") high stylus 935113* for 20mm (.79") high stylus 935114 for 30mm (1.18") high stylus 935115 for 42mm (1.65") high stylus Stylus (1. 40 57 ") 935116 935117 935118 935119 935120 For small hole stylus Unit: mm (inch) ø8 (.31") Unit: mm (inch) ø8 (.31") Stylus Eccentric type ø8 (.31") Straight type 15 155 9") ") (.5 (6.10 Unit: mm (inch) 95 ") 25 Stylus (3.74 (.98") 145 ") (5.71 for 6mm (.24") high stylus for 12mm (.47") high stylus for 20mm (.79") high stylus for 30mm (1.18") high stylus for 42mm (1.65") high stylus 935110 *Standard accessory — ARM AND STYLUS SET — • Consists of three special arms and five special styli. For CV-3000/4000 Order No. Components in set 996660 14 996660 996504 Straight arm for 6mm high stylus 996511 Eccentric arm for 20mm high stylus 996514 Arm for small hole stylus 354882 6mm high one-sided cut stylus 354889 20mm high intersecting cut stylus 354894 20mm high cone stylus 996540 Small hole stylus 996542 Small hole stylus — STYLI — For CV-3000/4000 For CV-1000/2000 ( CV-H628) One-sided cut Intersecting cut H H H Tip angle: 12° Tungsten carbide H 6mm (.24") 12mm (.47") 20mm (.79") 30mm (1.18") 42mm (1.65") Cone Order No. 354882 354883 354884** 354885 354886 Tip angle: 30° Sapphire or Tungsten carbide Tip angle: 20° Tungsten carbide H 6mm (.24") 12mm (.47") 20mm (.79") 30mm (1.18") 42mm (1.65") Order No. 354887 354888 354889 354890 354891 H 6mm (.24") 12mm (.47") 20mm (.79") 30mm (1.18") 42mm (1.65") ** CV-1000/2000/3000/4000 Standard accessory Knife edge Sapphire tip Tungsten tip Diamond H H Tip angle: 20° Edge width: 3mm Tungsten carbide Order No. 354897 354898 354899 354900 354901 Order No. 12AAA566 12AAA567 12AAA568 12AAA569 12AAA570 Ball H H 6mm (.24") 12mm (.47") 20mm (.79") 30mm (1.18") 42mm (1.65") Order No. 354892 354893 354894 354895 354896 Ball dia.: 1mm Tungsten carbide H 6mm (.24") 12mm (.47") 20mm (.79") 30mm (1.18") 42mm (1.65") Order No. 354902 354903* 354904 354905 354906 Cone Tip angle: 50° High accuracy type Diamond H 6mm (.24") 12mm (.47") 20mm (.79") 30mm (1.18") 42mm (1.65") Order No. — — 355129 — — *CV-H628 Standard accessory For CV-3000/4000 20 (.79") 996540 Tip angle: 20° Tungsten carbide ø4 (.16") ø5 (.2) ø3 (.12") ø4 (.16) 55 ") (2.17 2.5 (.10") 13 (.51") Unit: mm (inch) 1 (.04") 0.4 (.02") ø1.6 (.06") SMALL HOLE 55 ) (2.17 55 ") (2.17 996541 Tip angle: 20° Tungsten carbide 996542 Tip angle: 20° Tungsten carbide For CV-1000/2000 932693 Tip angle: 20° (one-sided cut) Tungsten carbide 9") (.7 20 ø8 (.32") (ø4.5mm or larger) 50 ") 97 (1. 932694 Tip angle: 20° (one-sided cut) Tungsten carbide 2.5 (.10") 0 9") 5 7") (.4 9 .5 (1. 12 ø4 (.16") ø6 (.24") ø3 (.12") ø6 (.16") (ø2.5mm or larger) 1 (.04") 0.4 (.02") ø1.6 (.06") SMALL HOLE Unit: mm (inch) (ø7mm or larger) ") 58 (1. ") 40 1.97 ( 50 932695 Tip angle: 20° (one-sided cut) Tungsten carbide Contracer CV Series 15 TECHNICAL DATA Contracer CV-H628 Model Number Order Number Selection 100V 110V 120V 220/230V 240V Specifications Model Measuring range Resolution X-axis Z-axis X-axis Z-axis Measuring X-axis accuracy (20°C) Z-axis Straightness of drive unit Stylus tip orientation Traversing direction Measuring force Maximum traceable angle Measuring speed Moving speed X-axis Column Digital data output Operating temperature Power supply Power consumption Dimensions Main unit (WxDxH) Control unit Vibration isolation table Side desk Mass Main unit Control unit Vibration isolation table Side desk Standard accessories CV-H628 200mm (8") 25mm (1") 0.00625µm (.25µinch) 0.0125µm (.5µinch) (0.5+0.003L)µm, (20+3L)µinch ±(0.5+ | 0.02H |)µm, ±(20+ | 20H |)µinch (0.3+0.002L)µm, (11.8+2L)µinch Downward Forward/backward 30mN (3gf) 60 degrees for upward/downward slope*** 0.02mm/s (.0008"/s) to 2mm/s (.08"/s), Can be specified by 7 steps. 0.1mm/s (.004/s") to 5mm/s (0.2"/s), Can be adjusted manually with a joystick box. 0.1mm/s (.004"/s) to 5mm/s (.2"/s), Can be adjusted manually with a joystick box. Via GPIB interface 10°C to 30°C 100V AC - 240V AC 150VA (at maximum) 765x450x890mm (30.1"x17.7"x35") 250x380x300mm (9.8"x15"x11.8") 1130x630x760mm (44.5"x24.8"x30") 620x940x1200mm (24.4"x37"x47.2") 140kg (308 Ibs.) 7kg (15.4 Ibs.) 130kg (286 Ibs.) 997123 Pin gage and holder 12AAA567 Cone stylus 354903 Ball stylus 12AAC169 Reversal mounting arm 211-016 Reference hemisphere 546-113 Dial tension gage 537976 Carrying bolts 178-042-1 Digimatic XY leveling table with swivel* 178-052-1 Digimatic XY leveling table with swivel** 178-016 Leveling table 355130 Machine cover Gauge blocks 613615-016 (5mm)* 613192-221 (.2")** 613671-016 (10mm)* 613194-221 (.4")** 613635-016 (25mm)* 613201-221 (1")** User's manual (1set), Fuse, Wrenches, Screw driver, Power cord, GND wire Gage blocks are provided with Grade K of /ISO/JIS/DIN or Grade 1of Federal Standard * for metric ** for inch/mm Dimensions Unit: mm (inch) 940 (37.01") Order number suffix denotes the AC power cord type equipped. CV-H628 mm inch/mm — 218-797 218-787C — 218-787A 218-797A 218-787D 218-797D 218-787E 218-797E 630 (24.8") Model Type Order No. 40kg (88 Ibs.) 1430 (56.30") 840 (33.07") 760 (29.92") 1600 (63") * L = Traverse length (mm [inch]) ** H = Measuring height (within ±25mm [±1inch]) ***Depends on the workpiece surface condition. 1130 (44.49") 16 620 (24.41") TECHNICAL DATA Contracer CV-1000/2000 Model Number Order Number Selection Model Type Order No. Order number suffix denotes the AC power cord type equipped. CV-1000N2 mm inch/mm 218-611 — 218-611C — 218-611A 218-621A 218-611D 218-621D 218-611E 218-621E 100V 110V 120V 220/230V 240V CV-2000M4 mm inch/mm 218-631 — 218-631C — 218-631A 218-641A 218-631D 218-641D 218-631E 218-641E Specifications Model Measuring range Resolution Measuring accuracy X-axis Z-axis X-axis Z-axis X-axis Z-axis Straightness Stylus tip orientation Traversing direction Measuring force Stylus traceable angle Stylus speed Digital data output Operating temperature Power supply Power consumption Dimensions Main unit (WxDxH) Display unit Mass Main unit Display unit Standard accessories CV-1000N2 CV-2000M4 50mm (2") 100mm (4") 25mm (1") 40mm (1.5") 0.2µm (.008µinch) 0.4µm (.016µinch) 0.5µm (.02µinch) (3.5+0.02L)µm [(138+20L)µinch]* ±(3.5+| 4H |/25)µm [ ±(138+ |157H | )µinch]** 3.5µm/50mm 3.5µm/100mm (.14µinch/2") (.14µinch/4") Downward Forward 10 to 30mN (1 to 3gf) Ascent:77º (depends on the workpiece surface condition) Descent: 87º (depends on the workpiece surface condition) 0.2mm/s (.008"/s) or 0.5mm/s (.02"/s) for tracing 0.2mm/s (.008"/s) or 1mm/s (.04"/s) or manual feeding for retracing) Via RS-232C interface 0°C to 40°C 100V AC - 240V AC 150VA (at maximum) 490x178x138mm 600x450x740mm (19.30"x7.01"x5.43") (23.62"x17.71"x18.80") 306x165x79mm (12.05"x6.50"x3.11") 5kg(11 Ibs.) 115.8kg( 255 Ibs.) 5kg(11 Ibs.) 357651 AC adapter 354884 High one-side cut stylus 935113 Straight arm 546-113 Dial tension gage, 537392 Thread gage (p=1mm)* 538333 Thread gage (p=.5")** Gauge blocks (CV-1000) 611615-041 (5mm)* 611192-231 (.2")** 611671-041 (10mm)* 611194-231 (.4")** 611625-041 (15mm)* 611196-231 (.6")** 611635-041 (25mm)* 611201-231 (1")** 611673-041 (30mm)* 611673-041 (30mm)** (CV-2000) 611671-041 (10mm)* 611194-231 (.4")** 611672-041 (20mm)* 611198-231 (.8")** 611674-041 (40mm)* 611201-231 (1")** User's manual (1set), Wrenches, Screw driver, Power cord, Connecting cables Gage blocks are provided with Grade 2 of /ISO/JIS/DIN or Federal Standard * for metric ** for inch/mm * L = Measuring length (mm [inch]) ** H = Measuring height from the horizontal (within ±12.5mm [±.5inch]) 118 (4.65") [39 (1.54")] [18.5(.73")] 20 (.79") 220 (8.66") [18.5 (.73")] 205 (8.07") [X= 25 (1") position] CV-1000N2 224 (9.6") 260 (10.24") 127 (5") 21 (.83") [24.7 (.97")] 450 (17.72") 100 (3.94") 44 (1.73") 113 (4.45") 15 (.6") [24.7 (.97")] 3 (.12") 12 (.47") 739.8 (29.13") 127 (5") [12 (.47")] 32 19 32 (.75") (1.26") (1.26") 105 (4.34") 20 (.79") 3 (.12") 34 (1.34") (Z= 0 position) 34 (1.34") 46 (1.81") 20 (.79") 4 (.16") (Z= 0 position) 39 (1.54") 61 (2.4") Unit: mm (inch) 34 (1.34") Dimensions 255 (10.04") 310 (12.2") [X= 50 (2") position] 92 (3.62") CV-2000M4 63 (2.48") 600 (23.62") Contracer CV Series 17 TECHNICAL DATA Contracer CV-3000/4000 Model Number Order Number Selection Model Type Order No. Order number suffix denotes the AC power cord type equipped. Model Type Order No. Order number suffix denotes the AC power cord type equipped. Model Type Order No. Order number suffix denotes the AC power cord type equipped. 100V 110V 120V 220/230V 240V CV-3000S4 mm inch/mm 218-652 218-662 218-652C — 218-652A 218-662A 218-652D 218-662D 218-652E 218-662E CV-3000H4 mm inch/mm 218-653 218-663 218-653C — 218-653A 218-663A 218-653D 218-663D 218-653E 218-663E CV-3000W4 mm inch/mm 218-654 218-664 218-654C — 218-654A 218-664A 218-654D 218-664D 218-654E 218-664E CV-3000S8 mm inch/mm 218-657 218-667 218-657C — 218-657A 218-667A 218-657D 218-667D 218-657E 218-667E 100V 110V 120V 220/230V 240V CV-3000H8 mm inch/mm 218-658 218-668 218-658C — 218-658A 218-668A 218-658D 218-668D 218-658E 218-668E CV-3000W8 mm inch/mm 218-659 218-669 218-659C — 218-659A 218-669A 218-659D 218-669D 218-659E 218-669E CV-4000S4 mm inch/mm 218-672 218-682 218-672C — 218-672A 218-682A 218-672D 218-682D 218-672E 218-682E CV-4000H4 mm inch/mm 218-673 218-683 218-672C — 218-673A 218-683A 218-673D 218-683D 218-673E 218-683E 100V 110V 120V 220/230V 240V CV-4000W4 mm inch/mm 218-674 218-684 218-674C — 218-674A 218-684A 218-674D 218-684D 218-674E 218-684E CV-4000S8 mm inch/mm 218-677 218-687 218-677C — 218-677A 218-687A 218-677D 218-687D 218-677E 218-687E CV-4000H8 mm inch/mm 218-678 218-688 218-678C — 218-678A 218-688A 218-678D 218-688D 218-678E 218-688E CV-4000W4 mm inch/mm 218-679 218-689 218-679C — 218-679A 218-689A 218-679D 218-689D 218-679E 218-689E Spesifications Model Measuring range Resolution CV-3000S4/4000S4 X-axis Z-axis X-axis Z-axis X-axis CV-3000H4/4000H4 CV-3000W4/4000W4 CV3000S8/4000S8 100mm (4") 50mm (2") CV-3000H8/4000H8 CV-3000W8/4000W8 200mm (8") 50mm (2") 0.00005mm (.000002") CV-3000 models: 0.0002mm (.000008") CV-4000 models: 0.00005mm (.000002") Measuring CV-3000S4/H4/W4: ±(1+2L/100)µm [±(40+20L)µinch]* CV-3000S8/H8/W8: ±(1+4L/200)µm [±(40+20L)µinch]* accuracy (20°C) CV-4000S4/H4/W4: ±(0.8+2L/100)µm [±(31+20L)µinch]* CV-4000S8/H8/W8: ±(0.8+4L/200)µm [±(31+20L)µinch]* Z-axis CV-3000 models: ±(3+|2H|/25)µm [±(120+|40H|)µinch]** CV-4000 models: ±(0.8+|0.5H|/25)µm [ ±(31+|10H|)µinch]** Linearity of drive unit 0.8µm/100mm (32µinch4/4") 2µm/200mm (80µinch/8") Drive unit vertical travel 250mm (10") 450mm (18") 250mm (10") 450mm (18") Drive unit inclinating range ±45 degrees Stylus tip orientation Downward/upward Traversing direction Forward/backward Measuring force 30mN (3gf) Maximum traceable angle 77 degrees for upward slope*** 87 degrees for downward slope*** Stylus speed Tracing 0.02mm/s (.0008"/s) to 2mm/s (.08"/s), Can be specified by 7 steps. Retracting 5mm/s (.2"/s) Positioning 0.1mm/s (.004"/s) to 5mm/s (.2"/s), Can be adjusted manually with a operation box. Digital data output Via RS-232C interface Operating temperature 15°C to 25°C Power supply 100V AC – 240V AC Power consumption 150VA (at maximum) Dimensions Main unit 741x450x905mm 741x450x1105mm 1118x450x1105mm 767x450x905mm 767x450x1105mm 1144x450x1105mm (WxDxH) (29.17"x17.7"x35.63") (29.17"x17.7"x43.5") (44.02"x17.7"x43.5") (30.2"x17.7"x35.63") (30.2"x17.7"x43.5") (45.04"x17.7"x43.5") Control unit 180x380x300mm (7.1"x15"x11.8") Operation box 245x116x78mm (9.6"x4.6"x3.1") Mass Main unit 140kg (308 lbs.) 150kg (330 lbs.) 150kg (330 lbs.) 145kg (319 lbs.) 155kg (341 lbs.) 155kg (341 lbs.) Control unit 6.5kg (14.3 lbs.) Operation box 0.8kg (1.76 lbs.) * L = Traverse length (mm [inch]) ** H = Measuring height (within ±25mm [±1inch]) ***Depends on the workpiece surface condition. 18 Standard accessories 354884 High one-side cut stylus 996506 Straight arm 546-113 Dial tension gage 178-043-1 Leveling table (CV-4000 only, for metric) 178-053-1 Leveling table (CV-4000 only, for inch/mm) 211-016 Symmetry calibration gage (CV-4000 only) 537976 Carrying bolts 352637 Lubricant 998862 Pin gage (mm) and holder* 537392 Thread gage (p=1mm)* 998861 Pin gage (inch) and holder** 538333 Thread gage (p=.05")** Gauge blocks (CV-3000) 611671-021 (10mm)* 611672-021 (20mm)* 611675-021 (50mm)* 611194-231 (.4")** 611198-231 (.8")** 611202-231 (2")** (CV-4000) 611671-017 (10mm)* 611672-017 (20mm)* 611675-017 (50mm)* 611194-221 (.4")** 611198-221 (.8")** 611202-221 (2")** User's manual (1set), Fuse, Wrenches, Screw driver, Connecting cables, Power cord, GND wire, Machine cover, Driving cable assy, Column cable assy Gage blocks are provided with Grade 0 of ISO/JIS/DIN or Grade 2 of Federal Standard for CV-3000 and Grade K of ISO/JIS/DIN or Grade 1 of Federal Standard for CV-4000 * for metric ** for inch/mm Dimensions (Example: CV-3000S4/ CV-4000S4) Main unit 300 (11.81") 905 (35.63") Unit: mm (inch) 180 (7.09") 380 (15") 78 (3.07") Control unit 245 (9.65") 610 (24.02") 450 (17.72") 116 (4.57") Operation box 741 (29.17") Contracer CV Series 19 Specifications are subject to change without notice. Kyung-hwa Tools & Machinery Co., Ltd Pukun BLD, 642 Omgung-dong, Sasang-gu, PUSAN, KOREA Tel : 051- 313-9300 Fax : 051-316-9092 Homepage : http://www.gagemall.com E-Mail : sale@gagemall.co.kr Printed in Japan 88.330201 (1) CBU
Similar documents
contracer - Measure-All
1. Point measurement: Point, peak, contact, intersection, bisector-point (between elements/pieces of measured data) 2. Line measurement: Line, tangent line, perpendicular, parallel line, bisector 3...
More information