FCU(A,F) fancoil

Transcription

FCU(A,F) fancoil
Integreret Combi Cooler–system
Energieffektiv ventilation og køling
FCUA
Fancoil
Air Handling: FCUA
FCU(A,F) Fan Coil Unit
FCU(A,F) fancoil
Tekniske data
DESCRIPTION
N 3896
Page 2
A–912
DESCRIPTION
The FCU(A,F) fan coil unit is a high-performance,
cost-effective and compact solution for the cooling of
technical compartments on board vessels. The
FCU(A,F) is the right solution where limited installation space and a cooling load exists. The three
FCU(A,F) unit sizes cover an airflow range of
0.15–0.6 m3/s and a cooling capacity range of
3–53 kW in the DX-coil variant and 2–45 kW in the
chilled-water coil variant.
Design
The FCU(A,F) casing is of double-skin sheet steel
design with intervening 25 mm thick mineral wool
insulation. Galvanized sheet steel or stainless sheet steel
of AISI 304 (SIS 2333) or AISI 316 (SIS 2343) quality
can be selected. The large service covers are equipped
with robust, easy-to-use handles; the covers can be lifted
off the unit after they have been opened.
The main components of the FCU(A,F) are installed in
a common casing at the factory. This minimizes the
installation work in ventilation systems and provides a
compact design. The smooth surfaces inside the unit
make the FCU(A,F) hygienic and easy to clean.
Overall dimensions
The FCU(A,F) has relatively small overall dimensions in
terms of its capacity and the airflow that it generates.
The three sizes of unit are 400, 450 and 500 mm high
respectively; and 605, 705 and 805 mm wide
respectively. The unit casing is 1185 mm long and the
base frame is 1385 mm long in all three unit sizes.
Thanks to its compact dimensions, the FCU(A,F) can
easily be situated in all the relevant spaces.
Installation options
The FCU(A,F) should normally be installed suspended
from a deck head or secured by means of bolts to the
deck. The vertical variant of the FCUA is designed for
bulkhead-mounting.
Applications
The FCU(A,F) fan coil unit is well-suited for chilling
the surplus heat arising in technical compartments on
board vessels. The unit uses 100% recirculated air.
FW: 3896 GB 2002.01 CC
The FCU(A,F) fan coil unit is a highperformance, cost-effective and compact
solution for the cooling of technical
compartments on board vessels. The
FCU(A,F) is the right solution where
limited installation space and a cooling
load exists. The three FCU(A,F) unit sizes
cover an airflow range of 0.15–0.6 m3/s
and a cooling capacity range of 3–53 kW
in the DX-coil variant and 2–45 kW in
the chilled-water coil variant.
Fan
The fan in the FCU(A,F) is a direct-driven, centrifugal fan
with forward-curved impeller blades. This eliminates the
drawbacks of belt-drive operation, such as the need for
retensioning or replacing drive belts and capacity losses.
The fan is isolated from the unit casing by means of antivibration mountings and a flexible duct. Therefore, the fan
coil unit does not require any extra external insulation.
Filter
The FCU(A,F) is available with two types of filter. The
FCUA has a Class EU3 flat filter with replaceable filter
mat whereas the FCUF has a Class EU5 disposable bagtype filter. The filter and the droplet eliminator are split
into two sections which reduces the amount of space
beside the unit needed for servicing.
Air cooler
– The DX-Coil air cooler is available in versions for
type R22, R407C and R134A refrigerant as well as
for chilled water. The coolers can be selected with
copper tubes and aluminium or copper fins. All the
types of air cooler are available in 4 capacity variants
with 3, 4, 6 or 8 tube rows arranged in the direction
of air flow.
– The chilled water coil (air cooler) has nipples for the
installation of a purging valve and an anti-frosting
protection sensor.
– A thermometer located downstream of the coil is
included in the supply.
Equipment/Accessories
The following additional equipment/accessories for the
FCU(A,F) are available:
– EUAZ-08 water trap for connection to the drain
connection of the drip tray beneath the cooling coil
– EUAZ-21 expansion valves for the DX-cooler (R22,
R407C, R134A)
– FCUZ replacement filters (EU3, EU5)
2
Alle rettigheder forbeholdes
FCU(A,F) Fan Coil Unit
Air Handling: FCUA
Tekniske data
FCU(A,F) fancoil
N 3896
Page 3
SIZING
SIZING
A–912
Sound power level, dB(A) 60 Hz
95
90
700
85 To ducts
Size 4
600
500
Size 3
400
Size 2
80
300
200
100
0
0
100
200
Air volume, I/s
300
400
500
600
Size 4
3
2
75
LwA, dB(A)
Static pressure rise, Pa
50 Hz
70
3
65 To
surroundings 4
60
2
55
50
0
100
200
Airflow, I/s
300
400
500
600
700
Static pressure rise, Pa
60 Hz
900
Size 4
800
Size 3
700
600
Size 2
500
400
300
200
100
0
0
100 200
Sound to the ducting and to the surroundings
The total sound power level to the fan outlet, LwA, can
be read from the fan chart. The following expression is
used for breaking down the sound into octave bands.
Lwduct = LwA + Kok
300
400
500
600
700
800
900
where Kok can be obtained from tables below.
Air volume, I/s
Kok Outlet-Duct
Average value
Sound data
Size 2
Size 3
Size 4
Sound power level, dB(A) 50 Hz
85
80
Octave band according to ISO
250 500 1000 2000 4000 8000
0
–6
–6
–7
–9
–12
1
–6
–7
–8
–10
–13
–3
–4
–8
–7
–9
–11
Kok To surroundings
3
2
70
Average value
65
LwA, dB(A)
125
4
3
2
Size 4
To ducts
75
Size 2
Size 3
Size 4
3
60 To
4
surroundings
55
2
50
63
125
13
3
12
7
4
8
Octave band according to ISO
250 500 1000 2000 4000 8000
2
1
4
–11
–4
–10
–11
–6
–12
–9
–12
–10
–8
–12
–10
–10
–17
–14
Kok Inlet-Duct
45
40
0
63
9
6
7
50
100 150
Airflow, I/s
FW: 3896 GB 2002.01 CC
200
250
300
350
400
450
500
Average value
Size 2
Size 3
Size 4
3
63
125
8
5
6
7
6
5
Octave band according to ISO
250 500 1000 2000 4000 8000
2
3
–1
–4
–4
–2
–5
–6
–7
–9
–10
–9
–14
–15
–14
–20
–21
–19
Alle rettigheder forbeholdes
Air Handling: FCUA
Tekniske data
FCU(A,F) Fan Coil Unit
FCU(A,F) fancoil
SIZING
SIZING
Pressure drop, ∆Pa
Air flow, m3/s
Size 3
0.44
FCU(A,F)-a-b-c
Size 4
0.6
Pressure drop ∆p, Pa
EU 3
EU 5
3 row
80
100
105
80
105
105
100
130
105
4 row
6 row
8 row
140
210
280
140
210
280
140
210
280
5
10
30
Droplet eliminator
1) Design pressure drop
2) Applicable to dry cooling. For other cases, the pressure drop can be
obtained from Cooler Calculation Computer Program CP 03.
Expansion valve
Refrigerant
R22
R 407C
R 134a
Code suffix
bb-cc-d
A–912
Motor data
Size 2
0.28
Function
Filter 1)
Filter 1)
Cooler 2)
N 3896
Page 4
Typ
kW
A
r/min
-2-6-c
-2-7-c
M2AA-71A
M2AA-71B
0.5
0.6/0.12
1.1
1.4
3370
3450/1760
-2-8-c
-3-6-c
-3-7-c
MT-71B 14-2
M2AA-80A
M2AA-80A
0.55
1.0
1.0/0.18
3.3
2.0
2.2
3440
3420
3460/1770
-3-8-c
-4-6-c
-4-7-c
MT-80A 19-2
M2AA-80A
M2AA-80A
0.75
1.0
1.0/0.18
4.6
2.0
2.2
3500
3420
3460/1770
-4-8-c
-2-1-c
-2-2-c
MT-80C 19-2
M2AA-71B
M2AA-71B
1.0
0.55
0.55/0.11
5.6
1.4
1.5
3510
2830
2840/1450
-2-3-c
-3-1-c
-3-2-c
-3-3-c
-4-1-c
-4-2-c
-4-3-c
MT-71B 14-2
M2AA-80A
M2AA-80A
MT-80A 19-2
M2AA-80B
M2AA-80B
MT-80C 19-2
0.55
0.75
0.8/0.15
0.75
1.1
1.1/0.2
1.0
3.8
1.8
2.2
4.9
2.5
2.8
6.3
2850
2840
2870/1470
2870
2850
2880/1470
2910
EUAZ-21-bb-cc-d
Output range, kW 1)
at a condensation temperature
30°C
35°C
42°C
33-02-2
33-02-3
33-02-4
33-02-5
33-02-6
33-05-3
33-05-4
33-12-4
2–4
3.5–7.6
5.5–11
7–14
9–17
12–25
20–41
28–58
2.5–5
4.2–8.5
6–12.5
8–16
9–19
15–30
24–48
33–67
2.5–4.6
4.5–9
7–13
8–16.5
10–20
16–32
25–50
36–75
34-02-3
34-02-4
34-02-5
34-02-6
34-05-1
34-05-2
34-05-3
34-05-4
34-12-4
2.4–4.7
3.5–7
4.4–8.8
5.4–10.8
6.7–13.3
9.8–18.6
14–28
20–40
26–53
2.5–5.3
3.9–7.8
4.9–9.9
6.1–12.1
7.1–14.2
11–21.4
15–31
22–44
30–60
2.6–5.7
4.2–8.4
5.4–10.8
6.5–13
7.9–15.8
11–23.1
15–32
23–46
31–63
1) The table is applicable to a total pressure drop in the refrigerant
circuit (excluding the expansion valve) of 150 kPa and at an evaporation temperature of 5 – 8° C.
FW: 3896 GB 2002.01 CC
4
Alle rettigheder forbeholdes
FCU(A,F) Fan Coil Unit
Air Handling: FCUA
Tekniske data
DIMENSIONS AND WEIGHTS
FCU(A,F) fancoil
DIMENSIONS AND WEIGHTS
Left-hand version
H
N 3896
Page 5
A–912
Chilled water coil
B
60
150
1185
D
C
G
1
0
200
E
110
F
70
475
70
ø 8.2
A
30
80
ø 32
ø 12
J
25
100
DX-Coil
180
CC
100
1385
1185
CxE
405
475
70
475
Chilled water coil
DX-Coil
R 25
ø 32
120
AA
BB
Size
2
3
4
AA
120
140
170
Rows
3
4
6
8
BB
58
87
144
205
405
3/8"
CC
135
165
225
285
100
ø 28.6
Size
A
B
C
D
E
F
G
H
J
2
3
4
330
380
430
605
705
805
160
180
220
120
180
230
110
110
160
55
85
95
65
90
115
300
400
500
520
620
720
Weight,
kg
75
100
122
ABB Products and Contracting
FW: 3896 GB 2002.01 CC
5
Alle rettigheder forbeholdes
FCU(A,F) Fan Coil Unit
Air Handling: FCUA
Tekniske data
FCU(A,F) fancoil
N 3896
Page 6
DIMENSIONS AND WEIGHTS
A–912
DIMENSIONS AND WEIGHTS
Dimensions and weights
Right-hand version
Chilled water coil
B
C
60
1185
D
150
H
G
1
0
A
200
E
F
110
70
30
80
475
70
ø 32
ø 12
ø 8.2
J
25
100
DX-Coil
1185
405
475
100
1385
CxE
180
CC
70
475
Chilled water coil
DX-Coil
R 25
120
AA
405
BB
Size
2
3
4
AA
120
140
170
Rows
3
4
6
8
BB
58
87
144
205
100
CC
135
165
225
285
FW: 3896 GB 2002.01 CC
ø 28.6
3/8"
Size
A
B
C
D
E
F
G
H
J
2
3
4
330
380
430
605
705
805
160
180
220
120
180
230
110
110
160
55
85
95
65
90
115
300
400
500
520
620
720
6
Weight,
kg
78
100
122
Alle rettigheder forbeholdes
FCU(A,F) Fan Coil Unit
Air Handling: FCUA
Tekniske data
N 3896
Page 7
DIMENSIONS AND WEIGHTS
FCU(A,F) fancoil
A–912
DIMENSIONS AND WEIGHTS
Dimensions and weights
Left-hand version
Chilled water coil
A
K
70
85
Safety
switch
1275
1105
AA
390
R 25
B
75
85
ø 32
C
ø 8.2
H
G
50
F
E
D
M
120
DX-Coil
685
BB
L
Rows
3
4
6
8
AA
58
87
144
205
BB
560
530
475
415
FW: 3896 GB 2002.01 CC
Size
A
B
C
D
E
F
G
H
K
L
M
2
3
4
760
760
860
210
260
260
460
560
560
605
705
805
160
180
220
120
180
230
110
110
160
125
165
165
330
380
430
285
335
385
150
210
225
7
Weight,
kg
73
97
117
Alle rettigheder forbeholdes
Air Handling: FCUA
FCU(A,F) Fan Coil Unit
Tekniske data
N 3896
Page 8
FCU(A,F) fancoil
A–912
DIMENSIONS AND WEIGHTS
Dimensions and weights
Right-hand version
Chilled water coil
K
A
70
85
Safety
switch
1275
1105
R 25
AA
390
B
75
85
ø 32
50
ø 8.2
G
H
120
M
C
F
E
D
DX-Coil
685
BB
180
Size
A
B
C
D
E
F
G
H
K
M
Weight,
kg
2
3
4
760
760
860
210
260
260
460
560
560
605
705
805
160
180
220
120
180
230
110
110
160
125
165
165
330
380
430
150
210
225
73
97
117
FW: 3896 GB 2002.01 CC
8
Rows
AA
BB
3
4
6
58
87
144
560
530
475
8
205
415
Alle rettigheder forbeholdes
Air Handling: FCUA
Tekniske data
FCU(A,F) Fan Coil Unit
FCU(A,F) fancoil
SPECIFICATION
SPECIFICATIONS
Fan Coil Unit
FCUA-a-b-c-d-e-f-g-h
Fan Coil Unit
A–912
FCUF-a-b-c-d-e-f-g-h
Size (a)
2, 3, 4
Size (a)
2, 3, 4
Voltage, frequency (b)
0 = Separate Coil
1 = 220 V delta, 380 V star, 50 Hz,
single speed, 2 poles
2 = 220 V delta, 380 V star, 50 Hz,
two-speed 2/4 poles
3 = 220 V, single-phase, 50 Hz
6 = 440 V star, 60 Hz, single-speed, 2 poles
7 = 440 V star, 60 Hz, two-speed, 2/4 poles
8 = 240 V, single-phase, 60 Hz
Voltage, frequency (b)
0 = Separate Coil
1 = 220 V delta, 380 V star, 50 Hz,
single speed, 2 poles
2 = 220 V delta, 380 V star, 50 Hz,
two-speed 2/4 poles
3 = 220 V, single-phase, 50 Hz
6 = 440 V star, 60 Hz, single speed, 2 poles
7 = 440 V star, 60 Hz, two-speed, 2/4 poles
8 = 240 V, single-phase, 60 Hz
Classification Society (c)
0 = Separate Coil
2 = Bureau Veritas
3 = Lloyds Register of Shipping
4 = Det Norske Veritas
5 = Germanischer Lloyd
6 = American Bureau of Shipping
Classification Society (c)
0 = Separate Coil
2 = Bureau Veritas
3 = Lloyds Register of Shipping
4 = Det Norske Veritas
5 = Germanischer Lloyd
6 = American Bureau of Shipping
Coil type (d)
1 = Chilled water, Cu/Al
2 = Chilled water, Cu/Cu
3 = DX, HFC 134A Cu/Al
4 = DX, HFC 134A Cu/Cu
Coil type (d)
1 = Chilled water, Cu/Al
2 = Chilled water, Cu/Cu
3 = DX, HFC 134A Cu/Al
4 = DX, HFC 134A Cu/Cu
Capacity variant (e)
3, 4, 6, 8
Capacity variant (e)
3, 4, 6, 8
Droplet Eliminator (f )
0 = Without
1 = With (h = 1, 2, 3, 4)
Droplet Eliminator (f )
0 = Without
1 = With (h = 1, 2, 3, 4)
Casing material (g)
1 = Galvanized steel sheet
5 = Stainless steel sheet AISI, 304, SIS 2333
7 = Stainless steel sheet AISI, 316, SIS 2343
Casing material (g)
1 = Galvanized steel sheet
5 = Stainless steel sheet, AISI 304, SIS 2333
7 = Stainless steel sheet, AISI 316, SIS 2343
Inspection side (h)
1 = Right-hand, horizontal outlet
2 = Left-hand, horizontal outlet
3 = Right-hand, vertical outlet
4 = Left-hand, vertical outlet
5 = Vertical unit, access right side
6 = Vertical unit, access left side
Inspection side (h)
1 = Right-hand, horizontal outlet
2 = Left-hand, horizontal outlet
3 = Right-hand, vertical outlet
4 = Left-hand, vertical outlet
FW: 3896 GB 2002.01 CC
9
N 3896
Page 9
Alle rettigheder forbeholdes
Air Handling: FCUA
Tekniske data
FCU(A,F) Fan Coil Unit
FCU(A,F) fancoil
SPECIFICATIONS
SPECIFICATION
Fan and motor
FCUA-99-bb-c-d-e-f
Make (bb)
02 = ABB motor with fan part
N 3896
Page 10
A–912
Filter for FCUA, set, horizontal
(one set = 2 cassettes)
FCUZ-01-b-2
Size (b)
2, 3, 4
Size (c)
2, 3, 4
Filter mat for FCUA, set, horisontal
(one set = 2 cassettes)
Voltage, frequency (d)
0 = Separate coil
1 = 220 V delta, 380 V star, 50 Hz,
single speed, 2 poles
2 = 220 V delta, 380 V star, 50 Hz,
two speed, 2/4 poles
3 = 220 V, single-phase 50 Hz
6 = 440 V star, 60 Hz, single speed, 2 poles
7 = 440 V star, 60 Hz, two speed, 2/4 poles
8 = 240 V, single-phase 60 Hz
FCUZ-02-b-2
Size (b)
2, 3, 4
Filter for FCUA, vertical
FCUZ-03-b
Size (b)
2, 3, 4
Filter for FCUF, set, horizontal
(one set = 2 cassettes)
Classification Society (e)
2 = Bureau Veritas
3 = Lloyds Register of Shipping
4 = Det Norske Veritas
5 = Germanischer Lloyd
6 = American Bureau of Shipping
FCUZ-04-b-2
Size (b)
2, 3, 4
Inspection side (f )
1 = Right-hand, horizontal outlet
2 = Left-hand, horizontal outlet
3 = Right-hand, vertical outlet
4 = Left-hand, vertical outlet
5 = Vertical unit, access right side
6 = Vertical unit, access left side
Fläkt Woods AB
SE-551 84 Jönköping
Sweden
Phone:
Int +46 36-19 30 00
Telefax:
Int +46 36-19 31 88
www.fläktwoods.com
FW: 3896 GB 2002.01 CC
10
Alle rettigheder forbeholdes
VEST:  ClimateConsult A/S | Petersmindevej 1 | DK-8362 Hørning | Tel.: +45 7022 2622 | Fax: +45 7022 2612
ØST:  ClimateConsult A/S | Stensmosevej 24A | DK-2620 Albertslund | Tel.: +45 7022 2696 | Fax: +45 7022 2697
post@clco.dk | www.climateconsult.dk