pharr road apartments
Transcription
pharr road apartments
PROJECT NARRATIVE: The proposed Pharr Rd & Grandview Ave residential development will occupy the site bounded by Pharr Rd to the North, Grandview Ave to the West and Lookout Place to the East. The project contains +/- 244 residential units (Levels 1-5) over two levels of podium parking deck (Levels P1-P2). The parking deck will be mechanically ventilated structured off-street parking for approximately 350 vehicles to support residential occupants and their guest. The grade change along the Pharr Rd frontage drops roughly 12’-0” from the western property line (Grandview Ave and Pharr Rd intersection) to the eastern property line. This grade change results in Level P1 being partially underground along Grandview and ½ of Pharr Rd. The apartment entry lobby and public entry for the parking deck will be located at the daylighted portion of Level P1 on Pharr Rd. Level P2 will be underground on 3 sides and daylight at the eastern most property line fronting Lookout Place. Residents only vehicular access will be provided from Lookout Place at Level P2. Level 1, located above structured parking, will be the first full residential floor and will also provide a Club Room, Fitness Center, and a landscaped amenity plaza containing a pool and additional outdoor amenities for tenants (Levels 1-5). The total gross residential area is approximately 276,000 SF with the residential building’s highest occupied floor being 5 stories or 56’ feet above Grandview Ave. Variation #1: Reduce Off-Street Loading Requirement from (3) 12’x35’ Spaces to (2) 12’x35’ Spaces Per zoning we are required to provide (3) 12’x35’ Spaces Variation #2: Request to provide minimum of 350 parking spaces (1 per bedroom + 25 additional for guests) Per zoning section 16.18I.023 calculation for minimum number of spaces would be 75% of (Total # of Units x 2) + (1/3 Total # of Units) = 427 Spaces Variation #3: Reduction of Supplemental Furniture Zone on Pharr Rd from 5’-0” to 1’-0” Per zoning SPI-9 Graphic Appendix and Standards Map Attachment B / Figure 13: Type 3 Streets the Supplemental Furniture Zone shown as 5’-0” Variation #4: Allow electrical transformer (installed by Georgia Power) to occupy Transitional Yard Per zoning section 16.18I.011 - 2.A : Transitional yard to be kept in a natural state and does not allow for paving or servicing C 2015 THIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC. ARCHITECTURE + INTERIOR DESIGN AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT COMMISSION NO. 14-035.00 FEBRUARY 27, 2015 L:\14-035 TCR Pharr Road Apartments\PRESENTATION\2015-02-25_DRC Presentation P H A R R R O A D A PA RT M E N T S AT L A N TA , G E O RG I A LEVEL B1 FLOOR PLAN 0’ CURB CUT LOOKOUT PLACE PHARR ROAD C 2015 THIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC. ARCHITECTURE + INTERIOR DESIGN AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT COMMISSION NO. 14-035.00 FEBRUARY 27, 2015 L:\14-035 TCR Pharr Road Apartments\PRESENTATION\2015-02-25_DRC Presentation P H A R R R O A D A PA RT M E N T S AT L A N TA , G E O RG I A 0’ 10’ 20’ 20’ 10’ 40’ 40’ LEVEL B2 FLOOR PLAN 0’ PHARR ROAD CURB CUT CURB CUT LOOKOUT PLACE LOBBY/ LEASING OFFICE C 2015 THIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC. ARCHITECTURE + INTERIOR DESIGN AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT COMMISSION NO. 14-035.00 FEBRUARY 27, 2015 L:\14-035 TCR Pharr Road Apartments\PRESENTATION\2015-02-25_DRC Presentation P H A R R R O A D A PA RT M E N T S AT L A N TA , G E O RG I A 20’ 0’10’ 10’ 20’ 40’ 40’ LEVEL 1 FLOOR PLAN 0’ 0’ PHARR ROAD CURB CUT 1BR 1BR 1BR AMENITY 2BR 1BR LOOKOUT PLACE G R A N DV I E W AV E N U E 1BR AMENITY 2BR 2BR 1BR 2BR AMENITY 1BR POOL 2BR 1BR 2BR 2BR 2BR 2BR 1BR 1BR 1BR 1BR 1BR CURB CUT 2BR C 2015 THIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LOADING 1BR 1BR 1BR 1BR 2BR 1BR LLC. FEBRUARY 27, 2015 L:\14-035 TCR Pharr Road Apartments\PRESENTATION\2015-02-25_DRC Presentation 2BR 1BR 1BR ARCHITECTURE + INTERIOR DESIGN AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT COMMISSION NO. 14-035.00 MEP 1BR 1BR 1BR 1BR P H A R R R O A D A PA RT M E N T S AT L A N TA , G E O RG I A 1BR 1BR CURB CUT 1BR 1BR 20’ 100’’ 10’ 20’ 10 0’10’ 40’ 40’ T Y P. L E V E L F L O O R P L A N 0’ 1BR 1BR 1BR 2BR 1BR 1BR 1BR 1BR 1BR 1BR 1BR 1BR 2BR 1BR 1BR 2BR 2BR 2BR 1BR 1BR 2BR 1BR 2BR 2BR 2BR 2BR 1BR 1BR 1BR 1BR 1BR 1BR 1BR 2BR 1BR 1BR 1BR 2BR 1BR 1BR C 2015 THIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC. ARCHITECTURE + INTERIOR DESIGN AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT FEBRUARY 27, 2015 L:\14-035 TCR Pharr Road Apartments\PRESENTATION\2015-02-25_DRC Presentation 1BR 1BR 1BR 2BR 1BR 1BR COMMISSION NO. 14-035.00 1BR 1BR 1BR 1BR P H A R R R O A D A PA RT M E N T S AT L A N TA , G E O RG I A 1BR 1BR 20’ 0’10’ 10’ 20’ 40’ 40’ PARKING ENTRY MAIN RESIDENTIAL ENTRY PH A R R ROA D E L EVAT I O N S O U T H E L EVAT I O N 0’ C 2015 THIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC. ARCHITECTURE + INTERIOR DESIGN AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT COMMISSION NO. 14-035.00 FEBRUARY 27, 2015 L:\14-035 TCR Pharr Road Apartments\PRESENTATION\2015-02-25_DRC Presentation P H A R R R O A D A PA RT M E N T S AT L A N TA , G E O RG I A 8’ 16’ 32’ PARKING ENTRY LO O KO U T P L AC E E L EVAT I O N EGRESS DOOR EGRESS DOOR EGRESS DOOR SERVICE DOORS G R A N DV I E W AV E N U E E L E VAT I O N 0’ C 2015 THIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC. ARCHITECTURE + INTERIOR DESIGN AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT COMMISSION NO. 14-035.00 FEBRUARY 27, 2015 L:\14-035 TCR Pharr Road Apartments\PRESENTATION\2015-02-25_DRC Presentation P H A R R R O A D A PA RT M E N T S AT L A N TA , G E O RG I A 8’ 16’ 32’ NORTH EAST CORNER VIEW C 2015 THIS DRAWING IS THE PROPERTY OF RULE JOY TRAMMELL + RUBIO, LLC. ARCHITECTURE + INTERIOR DESIGN AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT COMMISSION NO. 14-035.00 FEBRUARY 27, 2015 L:\14-035 TCR Pharr Road Apartments\PRESENTATION\2015-02-25_DRC Presentation P H A R R R O A D A PA RT M E N T S AT L A N TA , G E O RG I A February 27, 2015 Dennis Starling Livable Buckhead, Inc 3340 Peachtree Rd, NE Suite 1640 Atlanta, GA 30326 Re: Pharr Rd & Grandview Ave: Narrative of proposed project and list of Administrative Variations to be requested Project Narrative: The proposed Pharr Rd & Grandview Ave residential development will occupy the site bounded by Pharr Rd to the North, Grandview Ave to the West and Lookout Place to the East. The project contains +/- 244 residential units (Levels 1-5) over two levels of podium parking deck (Levels P1P2). The parking deck will be mechanically ventilated structured off-street parking for approximately 350 vehicles to support residential occupants and their guest. The grade change along the Pharr Rd frontage drops roughly 12’-0” from the western property line (Grandview Ave and Pharr Rd intersection) to the eastern property line. This grade change results in Level P1 being partially underground along Grandview and ½ of Pharr Rd. The apartment entry lobby and public entry for the parking deck will be located at the daylighted portion of Level P1 on Pharr Rd. Level P2 will be underground on 3 sides and daylight at the eastern most property line fronting Lookout Place. Residents only vehicular access will be provided from Lookout Place at Level P2. Level 1, located above structured parking, will be the first full residential floor and will also provide a Club Room, Fitness Center, and a landscaped amenity plaza containing a pool and additional outdoor amenities for tenants (Levels 1-5). The total gross residential area is approximately 276,000 SF with the residential building’s highest occupied floor being 5 stories or 56’ feet above Grandview Ave. Variation #1: Reduce Off-Street Loading Requirement from (3) 12’x35’ Spaces to (2) 12’x35’ Spaces Per zoning we are required to provide (3) 12’x35’ Spaces Variation #2: Request to provide minimum of 350 parking spaces (1 per bedroom + 25 additional for guests) Per zoning section 16.18I.023 calculation for minimum number of spaces would be 75% of (Total # of Units x 2) + (1/3 Total # of Units) = 427 Spaces Variation #3: Reduction of Supplemental Furniture Zone on Pharr Rd from 5’-0” to 1’-0” Per zoning SPI-9 Graphic Appendix and Standards Map Attachment B / Figure 13: Type 3 Streets the Supplemental Furniture Zone shown as 5’-0” Variation #4: Allow electrical transformer (installed by Georgia Power) to occupy Transitional Yard Per zoning section 16.18I.011 - 2.A : Transitional yard to be kept in a natural state and does not allow for paving or servicing