1746-2.35, Discrete Input and Output Modules, Technical Data
Transcription
1746-2.35, Discrete Input and Output Modules, Technical Data
Over 100 years cumulative experience 24 hour rush turnaround / technical support service Established in 1993 The leading independent repairer of servo motors and drives in North America. Visit us on the web: www.servo-repair.com www.servorepair.ca www.ferrocontrol.com www.sandvikrepair.com www.accuelectric.com Scroll down to view your document! For 24/7 repair services : USA: 1 (888) 932 - 9183 Canada: 1 (905) 829 -2505 Emergency After hours: 1 (416) 624 0386 Servicing USA and Canada Technical Data Discrete Input and Output Modules (Catalog Numbers 1746-IA4, -IA8, -IA16, -IB8, -IB16, -IB32, -IC16, -IG16, -IH16, -IM4, -IM8, -IM16, -IN16, -ITB16, -ITV16, -IV8, -IV16, -IV32, -OA8, -OA16, -OAP12, -OB6EI, -OB8, -OB16, OB16E, -OB32, OB32E, -OBP8, -OBP16, -OG16, -OV8, -OV16, OV32, -OVP16, -OW4, -OW8, -OW16, -OX8, -IO4, -IO8, -IO12, -IO12DC) Inside ........................................... page Discrete I/O Module Summary .......... 2 Features and Benefits ........................ 3 I/O Module Operation ........................ 5 Enhanced Discrete I/O Modules ........ 7 Terms and Symbols Used in the Specification Tables and Wiring Diagrams ....................................... 12 Specifications, Wiring, and Circuit Diagrams ....................................... 15 Fixed I/O Chassis and Module Compatibility ................................. 47 Discrete I/O Power Dissipation ........ 49 Environmental Specifications .......... 50 Accessories ...................................... 50 Allen-Bradley Support ...................... 51 Our wide variety of input, output, and combination modules makes the SLC 500™ family the smart choice for all of your small PLC applications.,2 PRGXOHVDUHDYDLODEOHLQDZLGHYDULHW\RIGHQVLWLHVLQFOXGLQJDQG SRLQWDQGFDQLQWHUIDFHWR$&'&DQG77/YROWDJHOHYHOV2XWSXW PRGXOHVDUHDYDLODEOHZLWKVROLGVWDWH$&VROLGVWDWH'&DQGUHOD\FRQWDFWW\SH RXWSXWV)RUDGGHGIOH[LELOLW\FRPELQDWLRQPRGXOHVDUHDOVRDYDLODEOHLQ LQSXWRXWSXWLQSXWRXWSXWDQGLQSXWRXWSXWYHUVLRQV Designed and tested for industrial applications, our modules are of the highest quality.7KHPRGXOHVIHDWXUHLQSXWILOWHULQJRSWLFDOLVRODWLRQDQG EXLOWLQVXUJHSURWHFWLRQWRHQKDQFHWKHUHOLDELOLW\RIRSHUDWLRQLQQRLV\ LQGXVWULDOHQYLURQPHQWV Class 1, Division 2 certified by UL and CSA. CE compliant.$OOPRGXOHVDUH 8/OLVWHGDQG&6$DSSURYHGDQGPHHW&ODVV'LYLVLRQ KD]DUGRXVORFDWLRQUHTXLUHPHQWVRIERWK8QGHUZULWHU·V/DERUDWRU\DQGWKH &DQDGLDQ6WDQGDUGV$VVRFLDWLRQH[FHSWIRUWKRVHQRWHGLQWKHPRGXOH VXPPDU\RQSDJH)RUXVHZLWKLQWKH(XURSHDQ8QLRQRU(($UHJLRQV PRVWPRGXOHVKDYHEHHQWHVWHGWRPHHW&RXQFLO'LUHFWLYH (OHFWURPDJQHWLF&RPSDWLELOLW\H[FHSWLRQVDUHOLVWHGRQSDJH 2 Discrete Input and Output Modules AC/DC Modules DC Modules AC Modules Discrete I/O Module Summary ID Code 100 300 500 101 301 501 2703 2903 2803 Voltage Category 100/120V ac 100/120V ac 100/120V ac 200/240V ac 200/240V ac 200/240V ac 100/120V ac 100/120V ac 120/240V ac 306 506 706 24V dc 24V dc 24V dc 519 509 507 320 520 720 24V dc 48V dc 125V dc 24V dc 24V dc 24V dc 518 515 24V dc 5V dc/TTL 2619 2713 2913 2920 24V dc 24V dc 24V dc 24V dc 3113 Input/Output Input Input Input Input Input Input Output Output Output I/O Points 4 8 16 4 8 16 8 16 12 Module Description 120V ac Input 120V ac Input 120V ac Input 240V ac Input 240V ac Input 240V ac Input 120/240V ac Output 120/240V ac Output High Current 120/240V ac Output Page 15 15 15 15 15 15 17 17 17 Input Input Input 8 16 32 Current Sinking DC Input Current Sinking DC Input Current Sinking DC Input 19 19 19 Input Input Input Input Input Input 16 16 16 8 16 32 Fast Response DC Sinking Input Current Sinking DC Input Current Sinking DC Input Current Sourcing DC Input Current Sourcing DC Input Current Sourcing DC Input 19 22 22 22 22 22 Input Input 16 16 Fast Response DC Sourcing Input Current Sourcing TTL Input 22 27 1746-OB16E(1)(3) Output Output Output Output 6 8 16 16 Isolated Sourcing DC Output Current Sourcing DC Output Current Sourcing DC Output Current Sourcing DC Output 31 28 28 31 24V dc 1746-OB32(1) Output 32 Current Sourcing DC Output 28 3120 24V dc 1746-OB32E(1) Output 32 Current Sourcing DC Output 31 2721 24V dc 1746-OBP8(3) Output 8 High Current Sourcing DC Output 31 2921 24V dc Output 16 High Current Sourcing DC Output 35 2714 2914 3114 24V dc 24V dc 24V dc 1746-OBP16(1) 1746-OV8 1746-OV16 1746-OV32(1) Output Output Output 8 16 32 Current Sinking DC Output Current Sinking DC Output Current Sinking DC Output 37 37 37 2922 24V dc 1746-OVP16(1) Output 16 High Current Sinking DC Output 40 2915 5V dc/TTL 1746-OG16(2) Output 16 Current Sinking TTL Output 41 510 2500 24V ac/dc AC/DC Relay 1746-IN16 1746-OW4(1) Input Output 16 4 24V ac/dc Input Relay (Hard Contact) Output 42 43 2700 AC/DC Relay 1746-OW8(1) Output 8 Relay (Hard Contact) Output 43 2900 AC/DC Relay 1746-OW16(1) Output 16 Relay (Hard Contact) Output 43 2701 AC/DC Relay 1746-OX8(1) Output 8 Isolated Relay Output 43 800 In - 120V ac, Out - Relay 1746-IO4 In - 120V ac, Out - Relay 1746-IO8(1) Input/Output 2 In, 2 Out Combination Input/Output 45 Input/Output 4 In, 4 Out Combination Input/Output 45 In - 120V ac, Out - Relay 1746-IO12(1) In - 24V dc, Out - Relay 1746-IO12DC(3) Input/Output 6 In, 6 Out Combination Input/Output 45 Input/Output 6 In, 6 Out Combination Input/Output 45 1100 1500 1512 Catalog Number 1746-IA4 1746-IA8 1746-IA16 1746-IM4 1746-IM8 1746-IM16 1746-OA8 1746-OA16 1746-OAP12(1) 1746-IB8 1746-IB16 1746-IB32(1) 1746-ITB16 1746-IC16 1746-IH16 1746-IV8 1746-IV16 1746-IV32(1) 1746-ITV16 1746-IG16(2) 1746-OB6EI 1746-OB8 1746-OB16 (1) (1) Certified for Class 1, Division 2 hazardous location by CSA only. (2) Not CE marked. (3) These modules carry the C-UL mark and are certified by UL per CSA only. Publication 1746-2.35 Discrete Input and Output Modules Features and Benefits 3 Select I/O modules to exactly match your application.&RPELQDWLRQ PRGXOHVDOORZ\RXWRKDYHLQSXWVDQGRXWSXWVLQDVLQJOHVORWIRUHIILFLHQWXVH RI\RXUFKDVVLVVSDFH Expand the I/O capacity of your fixed controller system. 7ZRGLVFUHWH,2 PRGXOHVFDQEHDGGHGWRWKHIL[HGFRQWUROOHU·VVORWH[SDQVLRQFKDVVLV LQFUHDVLQJWKHIOH[LELOLW\RIWKHV\VWHP All relay contacts are Silver Cadmium with Gold overlay. *ROGSODWLQJ UHVLVWVR[LGDWLRQDQGWDUQLVKLQJUHVXOWLQJIURPQRQXVH6LOYHU&DGPLXPDFWVDV DQH[FHOOHQWFRQGXFWRU High-density 32-Point DC I/O and fast response DC inputs are available. 7KHVHPRGXOHVDOORZ\RXWRDSSO\WKH6/&SURFHVVRUVLQDEURDGHU VSHFWUXPRIFRQWURODSSOLFDWLRQV INPUT LEDs indicate the status of each I/O point. IN 0 IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 IN 7 IN 8 IN 9 IN 10 IN 11 IN 12 IN 13 IN 14 IN 15 AC COM AC COM Terminal identification diagrams on each module LEDs indicate the status of each I/O point./('VLOOXPLQDWHWRDVVLVW\RXLQ WURXEOHVKRRWLQJZKHQWKHSURSHUVLJQDOLVUHFHLYHGDWDQLQSXWWHUPLQDORU ZKHQWKHSURFHVVRUDSSOLHVSRZHUWRDQRXWSXWWHUPLQDO Terminal identification diagrams on each module. 7HUPLQDOLGHQWLILFDWLRQ GLDJUDPVDUHORFDWHGRQHDFKPRGXOHPDNLQJWHUPLQDOLGHQWLILFDWLRQHDVLHU Publication 1746-2.35 4 Discrete Input and Output Modules Digital and field circuits are optically isolated. Self-locking tabs secure the module in the chassis. Removable terminal blocks are color coded for quick identification. Self-lifting field-wire pressure plates help reduce installation time. Barrier-type terminal blocks are provided on all modules. Digital and field circuits are optically isolated. $OOPRGXOHVIHDWXUHLVRODWLRQ EHWZHHQGLJLWDODQGILHOGFLUFXLWVUHVXOWLQJLQLQFUHDVHGQRLVHLPPXQLW\DQG OLPLWHGGDPDJHWR\RXUV\VWHPGXHWRDQHOHFWULFDOPDOIXQFWLRQRIWKHILHOG ZLULQJ Self-lifting field-wire pressure plates cut installation time.:LULQJWHUPLQDOV KDYHVHOIOLIWLQJSUHVVXUHSODWHVWRVHFXUHWZR$:*ILHOGZLUHV Removable terminal blocks help ease the wiring task. 5HPRYDEOHWHUPLQDO EORFNVDOORZ\RXWRUHSODFHWKHPRGXOHZLWKRXWUHZLULQJLWQRWDYDLODEOHRQDOO PRGXOHV Removable terminal blocks are color coded for quick identification. $ PDWFKLQJFRORUEDQGLVDOVRSURYLGHGRQWKHIURQWRIWKHPRGXOHWRDVVLVWLQ PDWFKLQJWKHWHUPLQDOEORFNWRWKHPRGXOH Barrier-type terminal blocks provided on all modules.(DFKWHUPLQDOEORFN IHDWXUHVDEDUULHURQWKUHHVLGHVRIHDFKWHUPLQDOWRKHOSSUHYHQWDFFLGHQWDO VKRUWLQJRIILHOGZLULQJ Self-locking tabs secure the module in the chassis. 1RWRROVDUHQHFHVVDU\ WRLQVWDOORUUHPRYHDPRGXOHIURPWKHFKDVVLV7RLQVWDOODPRGXOH\RXVOLGHLW LQWRWKHFKDVVLVXQWLOLWODWFKHVLQSODFH Publication 1746-2.35 Discrete Input and Output Modules I/O Module Operation 5 Power Supply Requirements 'LVFUHWHPRGXOHVUHFHLYHSRZHUWKURXJKWKH,2FKDVVLVEDFNSODQHIURP WKHDVVRFLDWHGFKDVVLVSRZHUVXSSO\5HIHUWRWKHLQGLYLGXDOPRGXOH VSHFLILFDWLRQVIRUWKHFXUUHQWUHTXLUHGIURPWKHSRZHUVXSSO\LQP$WR RSHUDWHWKHPRGXOH<RXVKRXOGWRWDOWKHFXUUHQWUHTXLUHPHQWVIRUDOOWKH PRGXOHVLQWKHFKDVVLVWRDYRLGRYHUORDGLQJWKHSRZHUVXSSO\RUWKH,2 FKDVVLVEDFNSODQH Input Modules $QLQSXWPRGXOHUHVSRQGVWRDQLQSXWVLJQDOLQWKHIROORZLQJPDQQHU ,QSXWILOWHULQJOLPLWVWKHHIIHFWRIYROWDJHWUDQVLHQWVFDXVHGE\FRQWDFW ERXQFHDQGRUHOHFWULFDOQRLVH,IQRWILOWHUHGYROWDJHWUDQVLHQWVFRXOG SURGXFHIDOVHGDWD$OOLQSXWPRGXOHVXVHLQSXWILOWHULQJ 2SWLFDOLVRODWLRQVKLHOGVEDFNSODQHFLUFXLWVDQGPRGXOHORJLFFLUFXLWVIURP SRVVLEOHGDPDJHGXHWRHOHFWULFDOWUDQVLHQWV /RJLFFLUFXLWVSURFHVVWKHVLJQDO $QLQSXW/('WXUQVRQRURIILQGLFDWLQJWKHVWDWXVRIWKHFRUUHVSRQGLQJ LQSXWGHYLFH Input Input Filtering Optical Isolation Logic Circuits Backplane LED Output Modules $QRXWSXWPRGXOHFRQWUROVWKHRXWSXWVLJQDOLQWKHIROORZLQJPDQQHU /RJLFFLUFXLWVGHWHUPLQHWKHRXWSXWVWDWXV $QRXWSXW/('LQGLFDWHVWKHVWDWXVRIWKHRXWSXWVLJQDO 2SWLFDOLVRODWLRQVHSDUDWHVPRGXOHORJLFDQGEDFNSODQHFLUFXLWVIURPWKH ILHOGVLJQDO 7KHRXWSXWGULYHUWXUQVWKHFRUUHVSRQGLQJRXWSXWRQRURII Backplane Logic Circuits Optical Isolation Output Drivers Output LED Publication 1746-2.35 6 Discrete Input and Output Modules Surge Suppression 0RVWRXWSXWPRGXOHVKDYHEXLOWLQVXUJHVXSSUHVVLRQWRUHGXFHWKHHIIHFWVRI KLJKYROWDJHWUDQVLHQWV+RZHYHUZHUHFRPPHQGWKDW\RXXVHDQDGGLWLRQDO VXSSUHVVLRQGHYLFHLIDQRXWSXWPRGXOHLVEHLQJXVHGWRFRQWURODQLQGXFWLYH GHYLFHVXFKDV • • • • UHOD\V PRWRUVWDUWHUV VROHQRLGV PRWRUV $GGLWLRQDOVXSSUHVVLRQLVHVSHFLDOO\LPSRUWDQWLI\RXULQGXFWLYHGHYLFHLVLQ VHULHVZLWKRUSDUDOOHOWRDKDUGFRQWDFWVXFKDV • SXVKEXWWRQV • VHOHFWRUVZLWFKHV %\DGGLQJDVXSSUHVVLRQGHYLFHGLUHFWO\DFURVVWKHFRLORIDQLQGXFWLYHGHYLFH \RXZLOOUHGXFHWKHHIIHFWVRIYROWDJHWUDQVLHQWVFDXVHGE\LQWHUUXSWLQJWKH FXUUHQWWRWKDWLQGXFWLYHGHYLFHDQGSURORQJWKHOLIHRIWKHVZLWFKFRQWDFWV 7KHGLDJUDPEHORZVKRZVDQRXWSXWPRGXOHZLWKDVXSSUHVVLRQGHYLFH VAC/VDC OUT 0 +DC or L1 Surge Suppressor OUT 1 AC or DC Output Module OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 COM DC COM or L2 5HFRPPHQGHGVXUJHVXSSUHVVRUVDUHSURYLGHGLQWKHVSHFLILFDWLRQVWDEOHV Important: $GGLQJDVXSSUHVVLRQGHYLFHDFURVV\RXUORDGZLOOGHIHDWWKHIDVW WXUQRIIIHDWXUHRIWKH2%(,2%(6HULHV%DQGODWHU 2%(2%36HULHV%DQGODWHU2%3DQG293'& RXWSXWPRGXOHV5HIHUWRSDJHVDQGIRUPRUH LQIRUPDWLRQDERXWVXSSUHVVLRQZKHQXVLQJWKH2%(, 2%(2%(2%32%3DQG293UHVSHFWLYHO\ Publication 1746-2.35 Discrete Input and Output Modules Enhanced Discrete I/O Modules 7 32-Point Modules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xx Connects 32-point module to DIN rail mountable terminal block 32-Point I/O Module Male MIL-C-83503 Header 1492-IFM40xx DIN rail mountable terminal block Publication 1746-2.35 8 Discrete Input and Output Modules Fast Response Input Modules (1746-ITB16, -ITV16) 7KHIDVWUHVSRQVH'&LQSXWPRGXOHVSURYLGHLQSXWSRLQWVDQGDUHGHVLJQHG IRUKLJKVSHHGDSSOLFDWLRQVUHTXLULQJIDVWUHVSRQVHWRLQSXWVLJQDOVIURP'& VHQVLQJGHYLFHV:KHQXVHGZLWKDQ6/&RUKLJKHUSURFHVVRUDQGWKH 'LVFUHWH,QSXW,QWHUUXSW',,LQVWUXFWLRQVHFSROOLQJSXOVHVFDQEH UHDGXSWRDIUHTXHQF\RI.+],WLV.+]LIWKHLQSXWVLJQDOVDUHIURPD JUD\FRGHHQFRGHU5HFRPPHQGHGZLULQJWRDQ$OOHQ%UDGOH\'$EVROXWH *UD\&RGH(QFRGHULVSURYLGHGRQSDJH %RWKVLQNLQJDQGVRXUFLQJYHUVLRQVRIWKHIDVWUHVSRQVHLQSXWPRGXOHDUH DYDLODEOH High-Current Solid-State Output Modules (1746-OAP12, -OB6EI, -OBP8, -OBP16, -OVP16) +LJKFXUUHQWVROLGVWDWHRXWSXWPRGXOHVH[SDQGDSSOLFDWLRQFRYHUDJHIRUWKH 6/&E\SURYLGLQJWKHIROORZLQJHQKDQFHGIXQFWLRQDOLW\ • • • • LQFUHDVHGFXUUHQWUDWLQJ IXVHSURWHFWLRQDQGGLDJQRVWLFV KLJKVSHHGVZLWFKLQJ H[FHOOHQWUHOLDELOLW\ 7KHKLJKFXUUHQWVROLGVWDWHRXWSXWPRGXOHVH[SDQGDSSOLFDWLRQFRYHUDJHLQ DXWRPRWLYHSDFNDJLQJDQGPDWHULDOKDQGOLQJDSSOLFDWLRQVE\DOORZLQJWKH6/& SURFHVVRUWRGLUHFWO\FRQWUROVROHQRLGVFRQWDFWRUVPRWRUVDQGPRWRU VWDUWHUORDGVXSWRVL]HZLWKFRQWLQXRXVFXUUHQWUHTXLUHPHQWVRIXSWR$DW °&2$32%3293DQG$DW°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ublication 1746-2.35 Discrete Input and Output Modules Blown Fuse LED OUTPUT F U S E FAC OBP16 Replaceable Fuse (F1) 1 AMP TRIAC JP 1 OUTPUT VOLTAGE SA ® OBP16 and OVP16 20.4 - 26.4 -------- ® UL Jumper for CPU Notification SER 3 2 1 SLC 500 OUTPUT MODULE 12 13 14 15 CAT 8 9 10 11 SERIAL NO. 4 5 6 7 F1 0 1 2 3 9 Jumper Settings and Fuse Replacement Information: OUTPUT RATINGS 6.4 AMP/MODULE 1.5 AMP/OUTPUT @ 30C 1.0 AMP/OUTPUT @ 60C WHEN FUSE OPENS 2 1 <---- CPU CONTINUES 2 <------- 3 3 CPU FAULTS 2 1 CPU CONTINUES CPU FAULTS WHEN FUSE OPENS 2 F1 FUSE REPLACEMENT LITTLEFUSE 322010 A-B CAT. NO. 1746-F8 MADE IN U.S.A. FUSE REPLACEMENT LITTLEFUSE 322010 A-B CAT. NO. 1746-F8 OVP12 Replaceable Fuse (F1) Blown Fuse LED OUTPUT F U S E 1 AMP TRIAC SER JP 1 WHEN FUSE OPENS 2 3 3 WHEN FUSE OPENS CPU CONTINUES 2 2 FUSE REPLACEMENT SAN-O HQ 6.3A A-B CAT. NO. 1746-F9 MADE IN U.S.A. 1 CPU FAULTS F2 Jumper Settings and Fuse Replacement Information: OUTPUT RATINGS 2.0A MAX @ 30 5C 1.25A MAX @ 55 5C 1.0A MAX @ 60 5C 240V MAX / 480 VA MAX 4.5A MAX/COMMON (MAX V.A. PER MODULE) 1440 VA OAP12 OUTPUT VOLTAGE 85-265 V AC 50/60 HZ 3 2 1 ® UL SA ® Replaceable Fuse (F1) Jumper for CPU Notification FAC F1 SLC 500 OUTPUT MODULE 8 9 10 11 CAT 4 5 6 7 SERIAL NO. 0 1 2 3 1 <---- CPU CONTINUES 2 <------- CPU FAULTS FUSE REPLACEMENT SAN-O HQ 6.3A A-B CAT. NO. 1746-F9 Replaceable Fuse (F2) Publication 1746-2.35 10 Discrete Input and Output Modules Electronically Protected Output Modules (1746-OB6EI, -OB16E, and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°&2%(DQG$DW &$DW&2%(PDNLQJWKHPWKHSHUIHFWVROXWLRQIRU FRQWUROOLQJ9GFDQG9GFVROHQRLGDQGODPSORDGV7KHPRGXOHVDUHDOVR HTXLSSHGZLWKDQ/('LQGLFDWRUWKDWLOOXPLQDWHVZKHQWKHVKRUWFLUFXLWRU RYHUORDGFRQGLWLRQRFFXUVWRH[SHGLWHWKHWURXEOHVKRRWLQJSURFHVV ,QGXFWLYHORDGWXUQRIIWLPHIRU2%(,DQG2%(6HULHV%DQGODWHU RXWSXWPRGXOHVLVUHGXFHGE\RYHUVWDQGDUG'&RXWSXWPRGXOHV DOORZLQJIDVWDSSOLFDWLRQF\FOHWLPHV OUTPUT Front View E F U S E EFUSE LED NOTE: There is no jumper setting on this module. Important: 7KHPRGXOHVGRQRWSURYLGHSURWHFWLRQDJDLQVWUHYHUVHSRODULW\ ZLULQJRUZLULQJWR$&SRZHUVRXUFHV(OHFWURQLFSURWHFWLRQLVQRW LQWHQGHGWRUHSODFHIXVHVFLUFXLWEUHDNHUVRURWKHUFRGHUHTXLUHG ZLULQJSURWHFWLRQGHYLFHV Publication 1746-2.35 Discrete Input and Output Modules 11 Overload Protection (1746-OB6EI, -OB16E, and -OB32E) 7KHFKDUWDQGWDEOHEHORZGHVFULEHRYHUORDGSURWHFWLRQIRUWKH2%(, 2%(DQG2%(7KHHOHFWURQLFSURWHFWLRQLVEDVHGRQDWKHUPDOFXWRXW WHPSHUDWXUHZKLFKLVUHDFKHGPRUHTXLFNO\DWORZHURYHUORDGFXUUHQWZKHQ WZRWRIRXUDGMDFHQWFKDQQHOVDUHRSHUDWLQJ7KHDGMDFHQWFKDQQHOJURXSLQJV DUH • 2%(,7KHFKDQQHOVRQWKLVPRGXOHVDUHQRWJURXSHGLQVHWV +RZHYHUFKDQQHOVZKLFKDUHGLUHFWO\DGMDFHQWWRRQHDQRWKHUZLOODOVR DOORZWKHWKHUPDOFXWRXWWHPSHUDWXUHWREHUHDFKHGPRUHTXLFNO\ • 2%(DQG • 2%(DQG Output Current (Amps) Overload Protection (Single channel operating at maximum rated current.) C Overload Protection (Two to four adjacent channels operating at maximum rated current.) D Recommended Operating Current B A 0 0 10 20 30 40 50 60 Operating Temperature (°C) Catalog Number Recommended Operating Current Overload Protection at 0°C (32°F) at 60°C (140°F) at 0°C (32°F) at 60°C (140°F) 1746-OB6EI A = 2A B = 2A C = 5.5A D = 4.5A 1746-OB16E A = 1A B = 0.5A C = 4A D = 3.5A 1746-OB32E A = 0.5A B = 0.25A C = 2A D = 1A Important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ublication 1746-2.35 12 Terms and Symbols Used in the Specification Tables and Wiring Diagrams Discrete Input and Output Modules Terms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ublication 1746-2.35 Discrete Input and Output Modules 13 6XUJH&XUUHQW3HU3RLQWWKHPD[LPXPDPSOLWXGHDQGGXUDWLRQSXOVHRI FXUUHQWDQRXWSXWFDQSURYLGHWRDQLQGXFWLYHRXWSXWGHYLFH 9ROWDJH&DWHJRU\WKHQRPLQDOYROWDJHXVHGWRGHVFULEHWKHPRGXOH I/O Wiring Symbols Symbol Device Name 2-wire Input Device 3-wire Input Device Solenoid Output CR L Contact Relay Output TTL Logic Output 5HODWHG3XEOLFDWLRQV'HWDLOHGZLULQJGLDJUDPVIRULQSXWPRGXOHVDQG $OOHQ%UDGOH\6HULHV3KRWRHOHFWULF6HQVRUVDUHSURYLGHGLQSXEOLFDWLRQ *5 Important: 7KHZLULQJGLDJUDPVLQWKLVGRFXPHQWDUHH[DPSOHVRQO\,WLVQRW QHFHVVDU\WRFRQQHFWDQ,2GHYLFHWRHYHU\WHUPLQDORQDQ,2 PRGXOH·VWHUPLQDOEORFN Publication 1746-2.35 14 Discrete Input and Output Modules Wiring Diagrams 7KHSRLQW,2PRGXOHZLULQJGLDJUDPVLQFOXGHERWKGHFLPDODQGRFWDO QXPEHUVIRU,2DGGUHVVLQJDQGZLUHLGHQWLILFDWLRQ6HHILJXUHEHORZ8VH WKHGHFLPDOQXPEHUVLQWKHXSSHUOHIWSRUWLRQRIHDFKER[WRZLUH\RXU SRLQW,2PRGXOHWRDQ6/&V\VWHP8VHWKHRFWDOQXPEHUVLQWKHORZHU ULJKWSRUWLRQRIWKHER[IRUD3/&V\VWHP$VVKLSSHGIURPWKHIDFWRU\WKH ,2PRGXOHKDVDGHFLPDODGGUHVVODEHORQWKHLQVLGHRILWVGRRU$QRFWDO ODEHONLWLVLQFOXGHGZLWK\RXUSRLQW,2PRGXOHVRU\RXFDQRUGHUD VHSDUDWHRFWDOFRQYHUVLRQNLWWRDOORZ\RXWRFRQYHUW\RXUPRGXOHWRWKHRFWDO V\VWHP Important: 3/&V\VWHPVXVHWKHRFWDOODEHOV6HHILJXUHEHORZ 'LUHFWLRQVRQKRZWRLQVWDOOWKHODEHOVDUHLQFOXGHGLQSXEOLFDWLRQQXPEHU 'LVFUHWH,20RGXOHV,QVWDOODWLRQ,QVWUXFWLRQV7KHVHLQVWUXFWLRQVDUH SURYLGHGLQDNLWWKDWLVVKLSSHGZLWKHDFKGLVFUHWH,2PRGXOH 1746-IA16 100/120V ac L1 IN 0 0 IN 1 2 IN 3 4 IN 5 6 IN 7 10 IN 9 12 IN 11 1 IN 2 3 IN 4 5 IN 6 100/120V ac 7 IN 8 11 IN 10 13 IN 12 14 IN 13 IN 14 15 16 IN 15 17 AC COM L2 AC COM Commons connected internally. SLC PLC For SLC (decimal) IN 14 16 For PLC (octal) Publication 1746-2.35 Discrete Input and Output Modules 15 Specifications, Wiring, and Circuit Diagrams Specification AC Input Modules (1746-IA4, -IA8, -IA16, -IM4, -IM8, -IM16) Catalog Number 1746-IA4 1746-IA8 Voltage Category Operating Voltage Number of Inputs Points per Common Backplane 5V dc Current Draw 24V dc Signal Delay (max.) 1746-IA16 (RTB) 100/120V ac 85 to 132V ac at 47 to 63 Hz 4 8 4 8 0.035A 0.050A 0.0A 0.0A on = 35 ms off = 45 ms 30V ac 2 mA 12 mA at 120V ac 0.8A Off-State Voltage (max.) Off-State Current (max.) Nominal Input Current Inrush Current(1) (max.) Inrush Current Time Duration(1) (max.) 1746-IM4 1746-IM8 1746-IM16 (RTB) 200/240V ac 170 to 265V ac at 47 to 63 Hz 4 8 4 8 0.035A 0.050A 0.0A 0.0A on = 35 ms off = 45 ms 50V ac 2 mA 12 mA at 240V ac 1.6A 16 16 0.085A 0.0A 500 µsec. 16 16 0.085A 0.0A 500 µsec. (1) An ac input device must be compatible with SLC 500 input circuit inrush current. A current limiting resistor can be used to limit inrush current; however, the operating characteristics of the ac input circuit are affected. RTB = Removable Terminal Block. On/Off-State Voltage Range + IN ± 0V ac 30V ac IA4, IA8, IA16 85V ac 132V ac 0V ac 50V ac IM4, IM8, IM16 170V ac 265V ac Off State Input State Not Guaranteed On State COM (Measure voltage from common terminal to input terminal. Circuit Diagrams 1746-IA4, IA8, IA16 AC COM 1746-IM4, IM8, IM16 270 1870 AC COM 261 1µF 261 1M 0.3µF 0.15µF IN 270 270 1870 1µF 0.3µF 1870 1µF 261 261 1M 1M IN 1870 1µF 1M IN 270 0.15µF IN Publication 1746-2.35 16 Discrete Input and Output Modules Wiring Diagrams 1746-IA4 100/120V ac 1746-IM4 200/240V ac 1746-IA8 100/120V ac NOT USED 1746-IM8 200/240V ac L1 IN 0 NOT USED IN 1 NOT USED L1 100/120V ac (IA4) 200/240V ac (IM4) IN 2 NOT USED 100/120V ac (IA8) IN 3 IN 0 200/240V ac (IM8) IN 4 IN 1 IN 5 IN 2 IN 6 IN 3 IN 7 AC COM L2 AC COM L2 Commons connected internally. 1746-IA16 100/120V ac 1746-IM16 200/240V ac L1 IN 0 0 IN 1 2 IN 3 1 IN 2 100/120V ac (IA16) 200/240V ac (IM16) 3 IN 4 4 IN 5 6 IN 7 10 IN 9 12 IN 11 5 IN 6 7 IN 8 11 IN 10 13 IN 12 14 IN 13 IN 14 15 16 IN 15 17 L2 AC COM AC COM Commons connected internally. SLC PLC Publication 1746-2.35 AC COM Discrete Input and Output Modules 17 AC Output Modules (1746-OA8, -OA16, -OAP12) Specification Catalog Number 1746-OA8(1) Voltage Category Operating Voltage Number of Outputs Points per Common Backplane 5V dc Current Draw 24V dc Signal Delay (max.)(Resistive Load) Off-State Leakage(3) (max.) Load Current (min.) Continuous Per Point(4) Current (max.) Per Module On-State Voltage Drop (max.) Surge Current per Point(5) (max.) 1746-OA16(1) (RTB) 1746-OAP12(1)(2) (RTB) 16 8 0.370A 0.0A 12 6 0.370A 0.0A 10 mA 1.0A at 30°C 0.50A at 60°C 0.50A at 30°C 0.25A at 60°C 8.0A at 30°C 4.0A at 60°C 1.50V at 1A 10.0A for 25 ms 8.0A at 30°C 4.0A at 60°C 1.50V at 0.50A 10.0A for 25 ms 2.0A at 30°C 1.25A at 55°C 1.0A at 60°C 9.0A at 30°C 6.0A at 60°C 1.2V at 2.0A per point - 17.0A for 25 ms per common - 35.0A for 10 ms 120/240V ac 85 to 265V ac at 47 to 63 Hz 8 4 0.185A 0.0A on = 1 ms off =11 ms 2 mA (1) Triac outputs turn on at any point in the ac line cycle and turn off at ac line zero cross. (2) A fused common and blown fuse LED are provided on this module. (Fuses are designed to protect the module.) For replacement fuse, use catalog number 1746-F9 or SAN-O HQ 6.3A. (3) To limit the effects of leakage current through triac outputs, a loading resistor can be connected in parallel with your load. For typical 120V ac applications, use a 15k ohm, 2W resistor. For typical 240V ac applications, use a 15k ohm, 5W resistor. (4) Recommended surge suppression for triac outputs when switching 120V ac inductive loads is Harris MOV part number V220MA2A. See page 6 for more information on surge suppression. (5) Repeatability is once every 1 second at 30°C. repeatability is once every 2 seconds at 60°C. RTB = Removable Terminal Block. Operating Voltage Range 85V ac 0V ac Operation Not Guaranteed 265V ac Recommended Operating Range (Voltage is applied between L1 and L2.) Important: ,I\RXPHDVXUHWKHYROWDJHDWDQRXWSXWWHUPLQDOWKDWLVQRW FRQQHFWHGWRDORDGRULVFRQQHFWHGWRDKLJKLPSHGDQFHORDG \RXPD\PHDVXUHDVPXFKDV9DFHYHQWKRXJKWKHRXWSXWLV RII Publication 1746-2.35 18 Discrete Input and Output Modules Circuit Diagrams 1746-OA8, OA16 1746-OAP12 L1 VAC OUT OUT OUT OUT Wiring Diagrams 1746-OA8 100-240V ac TRIAC OUTPUT 1746-OA16 100-240V ac TRIAC OUTPUT L1 VAC 1 VAC 1 L1 OUT 3 2 OUT 3 3 OUT 4 100-240V ac CR CR CR L2 CR 4 OUT 5 CR OUT 1 OUT 2 0 1 OUT 2 100-240V ac OUT 0 OUT0 OUT 1 5 OUT 6 CR 6 OUT 7 7 L2 VAC 2 L1 VAC 2 OUT 9 13 OUT 10 100-240V ac OUT 5 OUT 6 OUT 7 10 OUT 11 OUT 4 CR CR CR CR L2 L1 11 OUT 8 100-240V ac 12 OUT 13 15 OUT 12 OUT 15 CR 14 17 OUT 14 CR 16 SLC L2 PLC 1746-OAP12 100-240V ac HIGH CURRENT TRIAC OUTPUT Commons connected internally. VAC 1 L1 VAC 1 OUT 1 1 CR 100-240V ac CR OUT 3 OUT 5 OUT 0 0 3 OUT 2 2 5 OUT 4 NOT USED 4 CR NOT USED L2 L2 OUT 7 CR CR SLC PLC Publication 1746-2.35 7 OUT 6 6 11 OUT 8 10 OUT 11 13 OUT 10 12 VAC 2 VAC 2 OUT 9 100-240V ac CR Commons connected internally. L1 Discrete Input and Output Modules 19 Sinking DC Input Modules (1746-IB8, -IB16, -ITB16, -IB32) Specification Catalog Number 1746-IB8 1746-IB16 (RTB) Voltage Category Operating Voltage 24V dc sink 10 to 30V dc sink Number of Inputs Points per Common Backplane 5V dc Current Draw 24V dc Signal Delay (max.) 8 8 0.050A 0.0A on = 8 ms off = 8 ms 16 16 0.085A 0.0A on = 8 ms off = 8 ms Off-State Voltage (max.) Off-State Current (max.) Nominal Input Current 5V dc 1 mA 8 mA at 24V dc 5V dc 1 mA 1746-ITB16 (RTB) (Fast Response) 1746-IB32(1) 15 to 30V dc at 50°C sink 15 to 26.4V dc at 60°C sink 32 8 0.050A 0.0A on = 3 ms off = 3 ms 16 16 0.085A 0.0A on = 0.3 ms(2) off = 0.5 ms 5V dc 1.5 mA 5V dc 1.6 mA (1) Series A, B, and C 32-point input modules are fused to protect external wiring, one fuse per common. These fuses are non-replaceable and are rated at 2.5A. Series D 32-point input modules are not fused. (2) Typical signal delay for these modules: on = 0.10 ms, off = 0.25 ms at 24V dc. RTB = Removable Terminal Block. On/Off-State Voltage Range + IN ± 0V dc 5V dc 10V dc IB8, IB16, ITB16 0V dc 0V dc 5V dc 5V dc 15V dc 15V dc IB32 30V dc 30V dc at 50°C 26.4V dc at 60°C On State Off State COM (Measure voltage from common terminal to input terminal.) Input State Not Guaranteed Publication 1746-2.35 20 Discrete Input and Output Modules Circuit Diagrams 1746-ITB16 1746-IB8, IB16 2.8K IN 560 0.1µF 2.8K IN 3K IN 560 DC COM 560 0.1µF 560 3K IN 0.1µF 0.1µF DC COM 1746-IB32 4.3K IN 0.1µF 560 0.1µF 560 4.3K IN COM Wiring Diagrams 1746-IB16, ITB16 24V dc SINKING 1746-IB8 24V dc SINKING +DC IN 0 IN 2 IN 4 +DC 1 IN 1 2 IN 3 3 IN 2 4 IN 5 5 IN 6 24V dc IN 3 6 IN 7 7 6 10 IN 9 11 IN 10 24V dc IN 8 12 IN 11 IN 12 IN 4 IN 5 13 IN 6 14 IN 13 IN 14 –DC IN 0 0 IN 1 15 IN 7 16 IN 15 17 DC COM DC COM –DC DC COM DC COM Commons connected internally. Publication 1746-2.35 SLC PLC Commons connected internally. Discrete Input and Output Modules 21 1746-IB32 24V dc SINKING DC Com1 Wire Group 3 Wire Group 1 DC Com1 COM 1 COM 3 COM 1 COM 3 IN0 +VDC 1 IN1 IN2 0 1 IN18 2 IN3 2 IN19 3 IN4 3 IN20 4 IN5 4 IN21 5 IN6 5 IN22 6 IN7 6 IN23 7 IN8 7 IN24 10 IN9 10 IN25 11 IN10 11 IN26 12 IN11 12 IN27 13 IN12 13 IN28 14 IN13 14 IN29 15 IN14 15 IN30 16 IN15 DC Com2 Wire Group 2 16 IN31 17 DC Com2 +VDC 3 IN17 1 +VDC 2 DC Com3 IN16 0 Connector Key DC Com3 +VDC 4 17 COM 2 COM 4 COM 2 COM 4 DC Com4 Wire Group 4 DC Com4 SLC PLC Important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·VV\VWHPFDQ WROHUDWH7KHXVHU·VV\VWHPVKRXOGWDNHLQWRDFFRXQWWKHPLQLPXP WXUQRQYROWDJHUHTXLUHGE\H[WHUQDOORDGVFRQQHFWHGWRWKH SRLQWRXWSXWPRGXOHVDQGDOORIWKHYROWDJHGURSVDVVRFLDWHG ZLWKZLULQJWRDQGIURPWKHORDGWHUPLQDOEORFNVSRZHUVRXUFHV DQGWKHPRGXOHLWVHOI Publication 1746-2.35 22 Discrete Input and Output Modules Sinking DC Input Modules (1746-IC16, -IH16) Specification Catalog Number 1746-IC16 (RTB) Catalog Number 1746-IH16(1) (RTB) Voltage Category 48V dc sink 125V dc sink Operating Voltage 30 to 60V dc at 55°C sink 30 to 55V dc at 60°C sink 90 to 146V dc sink Max. Points on Simultaneously: 16 at 146V dc and 30°C 12 at 146V dc and 50°C 14 at 132V dc and 55°C 16 at 125V dc and 60°C Number of Inputs 16 16 Points per Common 16 16 5V dc 0.085A 0.085A 24V dc 0.0A 0.0A Signal Delay (max.) on = 4 ms / off = 4 ms on = 9 ms / off = 9 ms Off-State Voltage (max.) 10V dc 20V dc Off-State Current (max.) 1.5 mA 0.8 mA Nominal Input Current 4.1 mA at 48V dc 2.15 mA at 125V dc / 2.25 mA at 132V dc Backplane Current Draw (1) If the input module is connected in parallel with an inductive load, use surge suppression across the load to protect the input module from damage caused by reverse voltage. RTB = Removable Terminal Block. On/Off-State Voltage Range + IN (Measure voltage from common terminal to input terminal.) 0V dc 0V dc 10V dc 10V dc 30V dc 30V dc IC16 0V dc 20V dc 90V dc IH16 Input State Not Guaranteed ± Off State COM 55V dc at 60°C 60V dc at 55°C 146V dc On State (See table for max. number of points allowed on simultaneously.) Circuit and Wiring Diagrams 110K IN 51K 0.22µF 4.7K 1746-IC16 48V dc SINKING 1746-IH16 1746-IH16 125V dc SINKING +DC ZD CRD IN 0 IN 2 IN 4 110K IN 48V dc (IC16) 51K 0.22µF 4.7K 125V dc (IH16) 0 IN 1 1 2 IN 3 3 4 IN 5 5 6 IN 7 7 6 10 IN 9 11 IN 10 IN 6 IN 8 12 IN 11 ZD IN 12 CRD 13 14 IN 13 15 16 IN 15 17 DC COM DC COM IN 14 DC COM –DC IN 1746-IC16 11.2K Commons connected internally. 0.1µF DC COM Publication 1746-2.35 560 SLC PLC Discrete Input and Output Modules 23 Sourcing DC Input Modules (1746-IV8, -IV16, -ITV16, -IV32) Specification Catalog Number 1746-IV8 1746-IV16 (RTB) 1746-ITV16 (Fast Response) (RTB) Voltage Category Operating Voltage 24V dc source 10 to 30V dc source Number of Inputs Points per Common Backplane 5V dc Current Draw 24V dc Signal Delay (max.) 8 8 0.050A 0.0A on = 8 ms / off = 8 ms 16 16 0.085A 0.0A 16 16 0.085A 0.0A Off-State Voltage (max.) Off-State Current (max.) Nominal Input Current 5.0V dc 1 mA 8 mA at 24V dc 5.0V dc 1 mA on = 0.3 ms / off = 0.5 ms(2) 5.0V dc 1.5 mA 1746-IV32(1) 15 to 30V dc at 50°C source 15 to 26.4V dc at 60°C source 32 8 0.050A 0.0A on = 3 ms / off = 3 ms 5.0V dc 1.6 mA (1) Series A, B, and C 32-point input modules are fused to protect external wiring, one fuse per common. These fuses are non-replaceable and are rated at 2.5A. Series D 32-point input modules are not fused. (2) Typical signal delay for these modules: on = 0.100 ms, off = 0.25 ms for 24V dc. RTB = Removable Terminal Block. On/Off-State Voltage Range + IN ± 0V dc 5V dc 10V dc 0V dc 0V dc 5V dc 5V dc 15V dc 15V dc Off State COM (Measure voltage from common terminal to input terminal.) IV8, IV16, ITV16 IV32 30V dc 30V dc at 50°C 26.4V dc at 60°C On State Input State Not Guaranteed Publication 1746-2.35 24 Discrete Input and Output Modules Circuit Diagrams 1746-IV8, IV16 1746-ITV16 VDC VDC 560 0.1µF 560 0.1µF 2.8K 3K IN IN 560 0.1µF 560 0.1µF 2.8K 3K IN IN 1746-IV32 VDC 0.1µF 560 0.1µF 560 4.3K IN 4.3K IN Wiring Diagrams 1746-IV8 24V dc SOURCING 1746-IV16, ITV16 24V dc SOURCING –DC –DC IN 0 IN 0 IN 3 IN 3 1 3 IN 6 6 IN 7 10 IN 9 24V dc IN 8 IN 10 IN 5 IN 12 IN 6 +DC 5 7 11 12 IN 11 13 14 IN 13 IN 14 IN 7 VDC 2 4 IN 5 IN 4 +DC IN 1 IN 4 IN 2 24V dc 0 IN 2 IN 1 15 16 IN 15 17 VDC VDC VDC connected internally. VDC VDC connected internally. SLC PLC Publication 1746-2.35 Discrete Input and Output Modules 25 1746-IV32 24V dc SOURCING +VDC 1 Wire Group 3 Wire Group 1 VDC 1 +VDC 1 VDC 1 IN16 0 1 1 IN18 IN2 2 2 IN19 IN3 3 3 IN20 IN4 4 4 IN21 IN5 5 5 IN22 IN6 6 6 IN23 IN7 7 7 IN24 IN8 10 10 IN25 IN9 11 11 IN26 IN10 12 12 IN27 IN11 13 13 IN28 IN12 14 14 IN29 IN13 15 15 IN30 IN14 16 IN15 DC Com2 16 IN31 17 +VDC 2 DC Com3 0 IN17 IN1 Connector Key +VDC 3 VDC 3 IN0 DC Com1 +VDC 3 VDC 3 DC Com4 17 VDC 2 VDC 4 VDC 2 VDC 4 +VDC 4 +VDC 2 +VDC 4 Wire Group 2 Wire Group 4 SLC PLC Important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·VV\VWHPFDQ WROHUDWH7KHXVHU·VV\VWHPVKRXOGWDNHLQWRDFFRXQWWKHPLQLPXP WXUQRQYROWDJHUHTXLUHGE\H[WHUQDOORDGVFRQQHFWHGWRWKH SRLQWRXWSXWPRGXOHVDQGDOORIWKHYROWDJHGURSVDVVRFLDWHG ZLWKZLULQJWRDQGIURPWKHORDGWHUPLQDOEORFNVSRZHUVRXUFHV DQGWKHPRGXOHLWVHOI Publication 1746-2.35 26 Discrete Input and Output Modules 845D Absolute Gray Code Encoder to 1746-ITV16 0 2 Function Connector Pin Catalog Number 845D-NXC7914-2 Absolute Gray Code Encoder 0-359 (excess 76) Open Collector Output, 24V dc OUTPUTS A B C D E F G H J MSB9 Not Used 24V dc Filtered B+ Return, Signal Common Not Used L U V T S 1RWH Publication 1746-2.35 XSG0 LSB XSG1 XSG2 XSG3 XSG4 XSG5 XSG6 XSG7 XSG8 MSB 4 6 8 1 3 5 7 9 10 11 12 13 14 15 VDC VDC 1746-ITV16 +VDC –DC COM External Power Supply 7HUPLQDOVDQGFDQEHLQWHUFKDQJHGWRVHOHFW&:YV&&: GLUHFWLRQ5HIHUWR\RXUHQFRGHULQVWDOODWLRQPDQXDOIRUUHFRPPHQGHG FDEOHW\SHDQGOHQJWK Discrete Input and Output Modules 27 Sourcing TTL Input Module (1746-IG16) Specification Voltage Category Operating Voltage Number of Inputs Points per Common Backplane Current Draw 5V dc 24V dc Signal Delay (max.) Catalog Number 1746-IG16 (RTB) 5V dc TTL source 4.5 to 5.5V dc source 50 mV peak-to-peak ripple max. 16 16 0.140A 0.0A on = 0.25 ms off = 0.50 ms Off-State Voltage (max.) 2.0V dc(1) 4.1 mA 3.7 mA at 5V dc Off-State Current (max.) Nominal Input Current (1) TTL inputs are inverted (-0.2 to +0.8 = low voltage = True = on). Use a NOT instruction in your program to convert to traditional True = High logic. RTB = Removable Terminal Block. On/Off-State Voltage Range + –0.2V dc IN On State – 2V dc 0.8V dc 5.5V dc Input State Not Guaranteed Off State TTL inputs are inverted (-0.2 to +0.8 = low voltage = True = On.) COM (Measure voltage from common terminal to input terminal.) Circuit and Wiring Diagrams +5DC 1746-IG16 TTL INPUT (Low = True) 1.5K 1K 74HCT14 IN 560 +DC +5 DC IN 0 0 IN 1 1 IN 2 2 IN 3 3 IN 4 5 IN 6 7 IN 8 IN 5 4 6 IN 7 +5V dc IN 9 11 IN 11 13 IN 13 1.5K 1K IN 74HCT14 15 IN 15 560 10 IN 10 12 IN 12 14 IN 14 16 17 DC COM ±DC DC COM SLC PLC Publication 1746-2.35 28 Discrete Input and Output Modules Sourcing DC Output Modules (1746-OB8, -OB16, -OB32) Specification Catalog Number 1746-OB8 Voltage Category Operating Voltage Number of Outputs Points per Common Backplane Current 5V dc Draw 24V dc Signal Delay (max.) (Resistive Load) Off-State Leakage(2) (max.) Load Current (min.) Continuous Current (max.) Per Point(3) Per Module On-State Voltage Drop (max.) (5) Surge Current (max.) 24V dc 10 to 50V dc source 8 8 0.135A 0.0A on = 0.1 ms off = 1.0 ms 1 mA 1746-OB16 (RTB) 1746-OB32 Series D(1) 16 16 0.280A 0.0A on = 0.1 ms off = 1.0 ms 5 to 50V dc source 32 16 0.190A 0.0A on = 0.1 ms off = 1.0 ms 1 mA 1A at 30°C 0.50A at 60°C 8A at 30°C 4A at 60°C 0.50A at 30°C 0.25A at 60°C 8A at 30°C 4A at 60°C 1.2V at 1.0A 3A for 10 ms 1.2V at 0.5A 3A for 10 ms 0.5A at 30°C 0.25A at 60°C 8A at 0 to 60°C 4A at 0 to 60°C per common(4) 2A at 0 to 60°C per common pin 1.2V at 0.5A 1A for 10 ms (1) Series A, B, and C 32-point output modules are fused to protect external wiring, one fuse per common. These fuses are non-replaceable and are rated at 2.5A. Series D modules are not fused and have a higher current rating than Series A, B, and C. (2) To limit the effects of leakage current, a loading resistor can be connected in parallel with your load. For 24V dc operation use a 5.6k ohm, ½W resistor. (3) Recommended surge suppression for switching 24V dc inductive loads is a 1N4004 diode that is reverse wired across the load. See page 6 for more information on surge suppression. (4) To attain the maximum Continuous Current per common rating of 4A for an OB32 Series D module, both V dc connections in a wire group must be connected to your DC source. (5) Repeatability is once every second at 30°C. Repeatability is once every 2 seconds at 60°C. RTB = Removable Terminal Block. Operating Voltage Range 0V dc 10V dc OB8, OB16 50V dc 0V dc 5V dc OB32 50V dc Operation Not Guaranteed (Voltage is applied between +VDC and DC common.) Publication 1746-2.35 Recommended Operating Range Discrete Input and Output Modules 29 Circuit Diagrams 1746-OB8, OB16 1746-OB32 VDC VDC 18K OUT OUT 8.2K 1K OUT 18K OUT DC COM 8.2K COM Wiring Diagrams 1746-OB8 10-50V dc TRANSISTOR OUTPUT SOURCING 1746-OB16 10-50V dc TRANSISTOR OUTPUT, SOURCING +DC VDC VDC +DC OUT 0 0 OUT 1 OUT 2 1 OUT 0 2 OUT 3 OUT 1 CR OUT 2 10–50V dc OUT 3 OUT 4 CR 10–50V dc 3 OUT 4 5 OUT 6 7 OUT 8 4 OUT 5 6 OUT 7 OUT 9 CR 10 11 OUT 10 CR 12 OUT 11 13 OUT 12 OUT 5 CR CR OUT 6 CR DC COM 14 OUT 13 15 OUT 14 16 OUT 15 CR OUT 7 CR CR CR CR 17 DC COM –DC –DC SLC PLC Publication 1746-2.35 30 Discrete Input and Output Modules 1746-OB32 5-50V dc TRANSISTOR OUTPUT, SOURCING Wire Group 2 Wire Group 1 +VDC 1 +VDC 1 VDC 1 VDC 2 VDC 1 VDC 2 OUT0 CR +VDC 2 OUT16 0 0 1 1 OUT18 OUT2 CR 2 2 3 3 4 4 5 OUT6 5 OUT22 6 OUT7 CR CR 6 OUT23 7 OUT8 7 OUT24 10 OUT9 10 OUT25 11 OUT10 11 OUT26 12 OUT11 CR 12 13 CR CR 13 CR OUT28 14 OUT13 14 OUT29 15 OUT14 15 OUT30 16 OUT15 16 OUT31 17 DC Com1 CR OUT27 OUT12 DC Com1 CR OUT21 OUT5 Connector Key CR OUT20 OUT4 CR CR OUT19 OUT3 CR CR OUT17 OUT1 CR +VDC 2 17 COM 1 COM 2 COM 1 COM 2 DC Com2 DC Com2 SLC PLC Important: 7KH9GFDQGGF&RPSLQVRQWKH2%RXWSXWPRGXOHDUHLVRODWHGEHWZHHQ WKHWZRJURXSVDQGWKHWZRGF&RPSLQVLQHDFKJURXSDUHFRQQHFWHGLQWHUQDOO\ %RWK9GFSLQVRQWKH2%PXVWEHFRQQHFWHGWRWKHGFSRZHUVRXUFHLI FXUUHQWIRUDFRPPRQJURXSLVH[SHFWHGWRH[FHHG$PSV8VHDWHUPLQDO EORFNWRPDLQWDLQJURXSLVRODWLRQSURYLGHGE\SRLQW,2PRGXOHV&RQVXOW GRFXPHQWDWLRQRU\RXU$OOHQ%UDGOH\6DOHV2IILFHIRUDGGLWLRQDOLQIRUPDWLRQ 7KHSRLQWPRGXOHVLQFOXGHDNH\HGSLQIHPDOHFRQQHFWRUDQG FULPSW\SHSLQVIRUFRQQHFWLRQWR,2ZLULQJ,QDGGLWLRQSUHZLUHGFDEOHV DQGLQWHUIDFHPRGXOHVFDQEHXVHGIRUFRQQHFWLQJH[WHUQDO,26HHSDJHVDQG 7KHPD[LPXPXVHUFDEOHOHQJWKLVGHSHQGHQWRQKRZPXFKYROWDJHGURS>FXUUHQW[ RKPVIW[IHHW@WKHXVHU·VV\VWHPFDQWROHUDWH7KHXVHU·VV\VWHPVKRXOGWDNHLQWR DFFRXQWWKHPLQLPXPWXUQRQYROWDJHUHTXLUHGE\H[WHUQDOORDGVFRQQHFWHGWRWKH SRLQWRXWSXWPRGXOHVDQGDOORIWKHYROWDJHGURSVDVVRFLDWHGZLWKZLULQJWRDQG IURPWKHORDGWHUPLQDOEORFNVSRZHUVRXUFHVDQGWKHPRGXOHLWVHOI Publication 1746-2.35 Discrete Input and Output Modules 31 Electronically Protected Sourcing DC Output Modules (1746-OB6EI, -OB16E, -OB32E) Specification Voltage Category Operating Voltage Number of Outputs Points per Common Backplane Current Draw 5V dc 24V dc Signal Delay (max.) (Resistive Load)(1) Off-State Leakage(2) (max.) Load Current (min.) Continuous Current (max.) Per Point Catalog Number 1746-OB6EI (RTB) 24V dc 10 to 30V dc source 6 Individually Isolated 0.046A 0.0A on = 1.0 ms off = 2.0 ms 1 mA 1 mA 2.0A at 0 to 60°C 1746-OB16E (RTB) 1746-OB32E 16 16 0.135A 0.0A on = 1.0 ms off = 1.0 ms 32 16 0.190A 0.0A on = 1.0 ms off = 2.0 ms 1.00A at 30°C 0.50A at 60°C 8A at 0 to 60°C 0.50A at 30°C 0.25A at 60°C Per Module 12.0A at 0 to 60°C 8A at 0 to 60°C 4A at 0 to 60°C per common(3) 2A at 0 to 60°C per common pin On-State Voltage Drop (max.) 1.0V at 2A 1.0V at 0.5A 1.2V at 0.5A (4) Per Point 4.0A for 10 ms 2A for 10 ms 1.0A for 10 ms Surge Current (max.) Per Module 24.0A for 10 ms 32A for 10 ms 32A for 10 ms Electronic Protection yes - See page 10 for more information on the electronically protected modules. (1) Fast turn-off modules (1746-OB6EI, -OBP8 Series B and later, -OB16E Series B and later, -OBP16, and -OVP16) provide fast OFF delay for inductive loads. Fast turn-off delay for inductive loads is accomplished with surge suppressors on this module. A suppressor at the load is not needed unless another contact is connected in series. If this is the case, a 1N4004 diode should be reverse wired across the load. This defeats the fast turn-off feature. Comparative OFF delay times for 1746-OB8/-OV8 and fast turn-off modules, when switching Bulletin 100-B110 (24W sealed) contactor, are: 1746-OB8/-OV8 OFF delay = 152 ms; fast turn-off modules OFF delay = 47 ms. (2) To limit the effects of leakage current, a loading resistor can be connected in parallel with your load. For 24V dc operation use a 5.6k ohm, ½W resistor. (3) To attain the maximum Continuous Current per common rating of 4A for an OB32 Series D module, both V dc connections in a wire group must be connected to your DC source. (4) Repeatability is once every second at 30°C. Repeatability in once every 2 seconds at 60°C. RTB = Removable Terminal Block. Operating Voltage Range (Voltage is applied between +VDC and DC common.) 0V dc 10V dc Operation Not Guaranteed 1746-OB6EI 1746-OB16E 1746-OB32E 30V dc Recommended Operating Range Publication 1746-2.35 32 Discrete Input and Output Modules Circuit Diagrams 1746-OB6EI VDC IN OUT OUT COM 1746-OB16E VDC 0.1µF 6.2KΩ 2.4KΩ 0.1µF 0.1µF 100PF 0.1µF Logic and Protection Circuit 2.4KΩ OUT IN1 100pF IN2 6.2KΩ ST 1/2 6.2KΩ OUT 150µF DC COM 0.22µF 1KΩ 2.4KΩ Publication 1746-2.35 0.1µF Discrete Input and Output Modules 33 1746-OB32E 4.3K VDC IN1 OUT1 OUT IN2 OUT2 OUT IN3 OUT3 OUT IN4 OUT4 OUT 4.7K 4.7K 4.7K 4.7K DC COM Wiring Diagrams 1746-OB6EI 10-30V dc TRANSISTOR OUTPUT-SOURCING CHANNEL-TO-CHANNEL ISOLATED 1746-OB16E 10-30V dc TRANSISTOR OUTPUT, SOURCING +DC 10-30V dc CR VDC 3 +DC CR DC COM 3 +DC VDC 5 10-30V dc -DC +DC OUT 0 10-30V dc DC COM 0 -DC VDC 2 +DC OUT 2 DC COM 2 VDC 4 CR OUT 5 DC COM 5 0 1 OUT 2 3 OUT 4 5 OUT 6 7 OUT 8 2 OUT 3 CR 10–30V dc CR 10-30V dc -DC CR CR CR 12 14 OUT 13 15 OUT 14 16 OUT 15 +DC 10-30V dc 10 11 OUT 10 13 OUT 12 CR DC COM 4 6 OUT 7 OUT 11 -DC OUT 4 4 OUT 5 OUT 9 OUT 3 -DC OUT 0 OUT 1 VDC 0 OUT 1 DC COM 1 -DC 10-30V dc VDC VDC 1 +DC CR CR 17 DC COM –DC SLC PLC Publication 1746-2.35 34 Discrete Input and Output Modules 1746-OB32E 10-30V dc ELECTRONICALLY PROTECTED, SOURCING Wire Group 2 Wire Group 1 +VDC 1 +VDC 1 VDC 1 VDC 2 VDC 1 VDC 2 OUT0 CR +VDC 2 OUT16 0 0 1 1 OUT18 OUT2 CR 2 2 3 3 4 4 5 OUT6 5 OUT22 6 OUT7 CR CR 6 OUT23 7 OUT8 7 OUT24 10 OUT9 10 OUT25 11 OUT10 11 OUT26 12 OUT11 CR 12 13 CR CR 13 CR OUT28 14 OUT13 14 OUT29 15 OUT14 15 OUT30 16 OUT15 16 OUT31 17 DC Com1 CR OUT27 OUT12 DC Com1 CR OUT21 OUT5 Connector Key CR OUT20 OUT4 CR CR OUT19 OUT3 CR CR OUT17 OUT1 CR +VDC 2 17 COM 1 COM 2 COM 1 COM 2 DC Com2 DC Com2 SLC PLC Important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·VV\VWHPFDQWROHUDWH7KHXVHU·VV\VWHPVKRXOGWDNHLQWR DFFRXQWWKHPLQLPXPWXUQRQYROWDJHUHTXLUHGE\H[WHUQDOORDGVFRQQHFWHGWRWKH SRLQWRXWSXWPRGXOHVDQGDOORIWKHYROWDJHGURSVDVVRFLDWHGZLWKZLULQJWRDQG IURPWKHORDGWHUPLQDOEORFNVSRZHUVRXUFHVDQGWKHPRGXOHLWVHOI Publication 1746-2.35 Discrete Input and Output Modules 35 High Current Sourcing DC Output Modules (1746-OBP8, -OBP16) Specification Voltage Category Operating Voltage Number of Outputs Points per Common Backplane Current Draw Catalog Number 1746-OBP8 (RTB) 5V dc 24V dc Signal Delay (max.) (Resistive Load)(2) 1746-OBP16 (RTB)(1) 24V dc 20.4 to 26.4V dc source 8 16 4 16 0.135A 0.250A 0.0A 0.0A on = 1.0 ms / off = 2.0 ms Off-State Leakage(3) (max.) Load Current (min.) Continuous Current (max.) Per Point 1 mA Per Module On-State Voltage Drop (max.) Per Point Surge Current(4) (max.) Per Module 8.0A at 0° to 60°C 1V at 2A 4A for 10 ms 32A for 10 ms 1 mA 2.0A at 60°C 1.5A at 30°C 1.0A at 60°C 6.4A at 0° to 60°C 1V at 2A 4A for 10 ms 32A for 10 ms (1) A fused common and blown fuse LED are provided on this module. For replacement fuse, use catalog number 1746-F8 of Littlefuse 322010. See page 8 for additional information. (2) Fast turn-off modules (1746-OB6EI, -OBP8 Series B and later, -OB16E Series B and later, -OBP16, and -OVP16) provide fast OFF delay for inductive loads. Fast turn-off delay for inductive loads is accomplished with surge suppressors on this module. A suppressor at the load is not needed unless another contact is connected in series. If this is the case, a 1N4004 diode should be reverse wired across the load. This defeats the fast turn-off feature. Comparative OFF delay times for 1746-OB8/ -OV8 and fast turn-off modules, when switching Bulletin 100-B110 (24W sealed) contactor, are: 1746-OB8/-OV8 OFF delay = 152 ms; fast turn-off modules OFF delay = 47 ms. (3) To limit the effects of leakage current, a loading resistor can be connected in parallel with your load. For 24V dc operation use a 5.6k ohm, ½W resistor. (4) Repeatability is once every second at 30°C. Repeatability in once every 2 seconds at 60°C. RTB = Removable Terminal Block. Operating Voltage Range 0V dc (Voltage is applied between +VDC and DC common.) 20.4V dc Operation Not Guaranteed OBP8, OBP16 26.4V dc Recommended Operating Range Publication 1746-2.35 36 Discrete Input and Output Modules Circuit and Wiring Diagrams VDC 1746-OBP8 20.4-26.4V dc TRANSISTOR OUTPUT, SOURCING 6.19K +DC VDC1 S 8.87K OUT 0 G CR OUT 1 CR OUT 3 OUT 2 OUT X D 20.4–26.4 V dc DC COM1 NC NC NC -DC NC NC S NC VDC2 +DC G OUT 4 OUT Y D 20.4–26.4 V dc CR OUT 5 CR OUT 7 OUT 6 DC COM2 –DC COM VDC 6.19K 1746-OBP16 20.4-26.4V dc TRANSISTOR OUTPUT, SOURCING S G OUT D 8.87K +DC VDC OUT 0 0 OUT 1 OUT 2 1 2 OUT 3 CR 20.4–26.4V dc CR OUT 4 5 OUT 6 7 OUT 8 4 6 OUT 7 OUT 9 6.19K 3 OUT 5 10 11 OUT 10 CR 12 OUT 11 S 13 OUT 12 G D CR OUT 14 OUT 13 15 OUT 14 16 OUT 15 8.87K CR CR CR CR 17 DC COM –DC SLC PLC FLASH Publication 1746-2.35 Discrete Input and Output Modules 37 Sinking DC Output Modules (1746-OV8, -OV16, -OV32) Specification Catalog Number 1746-OV8 Voltage Category Operating Voltage Number of Outputs Points per Common Backplane 5V dc Current Draw 24V dc Signal Delay (max.) (Resistive Load) 24V dc 10 to 50V dc sink 8 8 0.135A 0.0A on = 0.1 ms / off = 1.0 ms Off-State Leakage(2) (max.) Load Current (min.) Continuous Per Point(4) (3) (max.) Current Per Module 1 mA On-State Voltage Drop (max.) Surge Current Per Point (6) (max.) 1746-OV16 (RTB) 1746-OV32 Series D(1) 5 to 50V dc sink 32 16 0.190A 0.0A 16 16 0.270A 0.0A 1 mA 1A at 30°C 0.5A at 60°C 8A at 30°C 4A at 60°C 0.5A at 30°C 0.25A at 60°C 8A at 30°C 4A at 60°C 1.2V at 1A 3A for 10 ms 1.2V at 0.5A 3A for 10 ms 0.5A at 30°C 0.25A at 60°C 8.0A at 0°C to 60°C 4A at 0 to 60°C per common(5) 2A at 0 to 60°C per common pin 1.2V at 0.5A 1A for 10 ms (1) Series A, B, and C 32-point output modules are fused to protect external wiring, one fuse per common. These fuses are non-replaceable and are rated at 2.5A. Series D modules are not fused and have a higher current rating than Series A, B, and C. (2) To limit the effects of leakage current, a loading resistor can be connected in parallel with your load. For 24V dc operation use a 5.6k ohm, ½W resistor. (3) To attain the maximum Continuous Current per common of 4A for an OV32 Series D module, both dc com connections in a wire group must be connected to your DC source. (4) Recommended surge suppression for switching 24V dc inductive loads is a 1N4004 diode that is reverse wired across the load. See page 6 for more information on surge suppression. (5) To attain the maximum Continuous Current per common rating of 4A for an OV32 Series D module, both V dc connections in a wire group must be connected to your DC source. (6) Repeatability is once every 1 second at 30°C. Repeatability is once every 2 seconds at 60°C. RTB = Removable Terminal Block. Operating Voltage Range 0V dc 10V dc OV8, OV16 50V dc 0V dc 5V dc OV32 50V dc Operation Not Guaranteed Recommended Operating Range (Voltage is applied between +VDC and DC common.) Publication 1746-2.35 38 Discrete Input and Output Modules Circuit Diagrams 1746-OV8, OV16 1746-OV32 VDC VDC 8.2K OUT OUT 18K OUT DC COM 8.2K OUT COM 18K Wiring Diagrams 1746-OV8 10-50V dc TRANSISTOR OUTPUT SINKING VDC 1746-OV16 10-50V dc TRANSISTOR OUTPUT, SINKING +DC VDC +DC OUT 0 OUT 0 OUT 1 OUT 1 OUT 3 CR OUT 2 OUT 3 10–50V dc 10–50V dc OUT 4 CR OUT 5 CR OUT 6 OUT 7 DC COM 0 1 OUT 2 3 OUT 4 5 OUT 6 7 OUT 8 2 4 OUT 5 OUT 7 CR 6 CR 10 OUT 9 11 OUT 10 12 OUT 11 13 OUT 12 15 OUT 14 14 OUT 13 CR CR CR CR –DC –DC OUT 15 17 16 CR CR CR DC COM SLC PLC Publication 1746-2.35 Discrete Input and Output Modules 39 1746-OV32 5-50V dc TRANSISTOR OUTPUT, SINKING Wire Group 2 Wire Group 1 +VDC 1 VDC 1 VDC 1 +VDC 1 CR +VDC 2 VDC 2 OUT0 OUT16 0 0 OUT17 OUT1 CR 1 1 2 2 OUT19 OUT3 CR 3 OUT4 3 4 5 OUT22 6 6 OUT23 OUT7 7 7 OUT24 OUT8 10 OUT9 10 OUT25 11 CR CR OUT10 11 CR CR OUT26 12 OUT11 12 OUT27 13 13 CR CR OUT28 OUT12 14 OUT13 14 OUT29 15 OUT14 15 OUT30 16 OUT15 16 OUT31 17 DC Com1 CR 4 5 CR CR OUT21 OUT6 Connector Key CR OUT20 OUT5 CR CR OUT18 OUT2 CR +VDC 2 VDC 2 17 COM 1 COM 2 COM 1 COM 2 DC Com2 DC Com2 DC Com1 SLC PLC Important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·VV\VWHPFDQWROHUDWH7KHXVHU·VV\VWHP VKRXOGWDNHLQWRDFFRXQWWKHPLQLPXPWXUQRQYROWDJHUHTXLUHGE\H[WHUQDO ORDGVFRQQHFWHGWRWKHSRLQWRXWSXWPRGXOHVDQGDOORIWKHYROWDJHGURSV DVVRFLDWHGZLWKZLULQJWRDQGIURPWKHORDGWHUPLQDOEORFNVSRZHUVRXUFHV DQGWKHPRGXOHLWVHOI Publication 1746-2.35 40 Discrete Input and Output Modules High Current Sinking DC Output Module (1746-OVP16) Specification Catalog Number Voltage Category Operating Voltage Number of Outputs Points per Common Backplane Current Draw 1746-OVP16 (1) (2)(RTB) 24V dc 20.4 to 26.4V dc sink 16 16 0.25A 0.0A on = 0.1 ms / off = 1 ms 1 mA 5V dc 24V dc Signal Delay (max.) (Resistive Load) Off-State Leakage(3) (max.) Load Current (min.) 1 mA 1.5A at 30°C / 1A at 60°C 6.4A at 0°C to 60°C 1V at 1A 4A for 10 ms 32A for 10 ms Per Point Per Module Continuous Current (max.) On-State Voltage Drop (max.) Per Point Per Module Surge Current(4) (max.) (1) A fused common and blown fuse LED are provided on this module. (2) Fast turn-off modules (1746-OB6EI, -OBP8 Series B and later, -OB16E Series B and later, -OBP16, and -OVP16) provide fast OFF delay for inductive loads. Fast turn-off delay for inductive loads is accomplished with surge suppressors on this module. A suppressor at the load is not needed unless another contact is connected in series. If this is the case, a 1N4004 diode should be reverse wired across the load. This defeats the fast turn-off feature. Comparative OFF delay times for 1746-OB8/-OV8 and fast turn-off modules, when switching Bulletin 100-B110 (24W sealed) contactor, are: 1746-OB8/-OV8 OFF delay = 152 ms; fast turn-off modules OFF delay = 47 ms. (3) To limit the effects of leakage current, a loading resistor can be connected in parallel with your load. For 24V dc operation use a 5.6k ohm, ½W resistor. (4) Repeatability is once every 1 second at 30°C. Repeatability is once every 2 seconds at 60°C. RTB = Removable Terminal Block. Operating Voltage Range 0V dc (Voltage is applied between +VDC and DC common.) 20.4V dc Recommended 26.4V dc Operating Range Operation Not Guaranteed Circuit and Wiring Diagrams 1746-OVP16 20.4-26.4V dc TRANSISTOR OUTPUT, SINKING VDC +DC VDC OUT 0 8.87K D G 6.19K 0 OUT 1 OUT 1 OUT 2 3 OUT 4 5 OUT 6 7 OUT 8 2 OUT 3 S CR 20.4-26.4V dc 4 OUT 5 OUT 7 CR 6 CR 10 OUT 9 11 OUT 10 12 OUT 11 13 OUT 12 15 OUT 14 14 OUT 13 CR 8.87K D G OUT CR ±DC 6.19K S 17 16 CR CR DC COM SLC PLC DC COM Publication 1746-2.35 OUT 15 CR Discrete Input and Output Modules 41 Sinking TTL Output Module (1746-OG16) Specification Catalog Number 1746-OG16 (RTB) Voltage Category 5V dc TTL(1) Operating Voltage Range 4.5 to 5.5V dc 50 mV peak-to-peak ripple maximum 495 mA maximum at 5V dc Number of Outputs 16 Points per Common 16 Backplane Current 5V dc 0.180A Draw 24V dc 0.0A Signal Delay (max.) (Resistive Load) on = 0.25 ms / off = 0.5 ms Off-State Leakage (max.) 0.1 mA Load Current (min.) 0.15 mA 24 mA Continuous Current (max.) (1) TTL outputs are inverted (0-0.4V dc = low voltage = True = On). Use a NOT instruction in your ladder program to convert to traditional True = High logic. RTB = Removable Terminal Block. On/Off-State Voltage Range + (Measure voltage from common terminal to input terminal.) OUT 0V dc 4.5V dc 0.4V dc On State 5.5V dc Operation Not Guaranteed – Off State TTL inputs are inverted (0-0.4 V dc = low voltage = true = On). COM Circuit and Wiring Diagrams +5DC 1746-OG16 TTL OUTPUT (Low = True) 74AC14 +DC VDC OUT L OUT 0 +5V dc L OUT 1 L OUT 3 L OUT 5 L OUT 7 L OUT 9 L OUT 11 L OUT 13 74AC14 L OUT –DC 0 1 OUT 2 L 2 3 OUT 4 5 OUT 6 7 OUT 8 L 4 L 6 L 10 11 OUT 10 12 13 OUT 12 14 15 OUT 14 OUT 15 16 L L L 17 DC COM SLC PLC DC COM Publication 1746-2.35 42 Discrete Input and Output Modules AC/DC Input Module (1746-IN16) Specification Voltage Category Operating Voltage Number of Inputs Points per Common Backplane Current Draw 5V dc 24V dc Signal Delay (max.) Off-State Voltage (max.) Off-State Current (max.) Nominal Input Current Inrush Current (max.) Catalog Number 1746-IN16 (RTB) 24V ac/dc 10 to 30V dc sink 10 to 30V ac at 47 to 63 Hz 16 16 0.085A 0.0A dc: on = 15 ms / off = 15 ms ac: on = 25 ms / off = 25 ms 3V dc 3V ac 1 mA dc 1 mA ac 8 mA at 24V dc 8 mA at 24V ac 0.02A (ac only) RTB = Removable Terminal Block. On/Off-State Voltage Range 0V ac 0V dc (Measure voltage from common terminal to input terminal.) 3V ac 3V dc 10V ac 10V dc 30V ac 30V dc + IN Off State – Input State Not Guaranteed On State COM Circuit and Wiring Diagrams L1 or +DC AC/DC COM 1746-IN16 24V ac/dc SINKING IN 0 1µF IN 270 261 0 IN 1 2 IN 3 4 IN 5 1 IN 2 1870 3 IN 4 V ac/dc 5 IN 6 6 IN 7 7 IN 8 10 IN 9 11 IN 10 12 IN 11 13 IN 12 14 IN 13 1µF IN 270 1870 15 IN 14 261 16 IN 15 L2 or –DC AC/DC COM 17 AC/DC COM Commons connected internally. Publication 1746-2.35 SLC PLC Discrete Input and Output Modules 43 AC/DC Relay Output Modules (1746-OW4, -OW8, -OW16, -OX8) Specification Catalog Number 1746-OW4 Voltage Category Operating Voltage Number of Outputs Points per Common Backplane Current 5V dc Draw 24V dc Signal Delay (max.) (Resistive Load) Off-State Leakage (max.) Load Current (min.) Continuous Current per Point(1) (max.) Continuous Current per Module (max.) Current per Common (max.) 1746-OW8 1746-OW16 (RTB) ac/dc Relay 5 to 265V ac at 47 to 63 Hz / 5 to 125V dc 4 8 16 4 4 8 0.045A 0.085A 0.170A 0.045A 0.090A 0.180A on = 10 ms / off = 10 ms 0 mA 10 mA at 5V dc See the Relay Contact Ratings tables shown below. 8.0A ac 8.0A 16.0A ac 8.0A 16.0A ac 8.0A 1746-OX8 (RTB) 8 Individually Isolated 0.085A 0.090A (2) Relay Contact Ratings for 1746-OW4, OW8, and OW16 Maximum Volts ac dc 240V ac 120V ac 125V dc 24V dc Amperes(1) Make 7.5A 15A Break 0.75A 1.5A Amperes Continuous(2) Volt-Amperes 2.5A Make 1800 VA 0.22A(3) 1.0A 28 VA 1.2A(3) 2.0A Break 180 VA Relay Contact Ratings for 1746-OX8 Maximum Volts ac dc 240V ac 120V ac 125V dc 24V dc Amperes(1) Make 15A 30A Break 1.5A 3.0A Amperes Continuous(2) Volt-Amperes 5.0A Make 3600 VA 0.22A(3) 1.0A 28 VA 1.2A(3) 2.0A Break 360 VA (1) Connecting surge suppressors across your external load extends the life of SLC 500 relay contacts. For recommended surge suppressors when switching ac inductive loads, consult the SLC 500 Modular Hardware Style Installation and Operation User Manual (Publication 1746-6.2) or the SLC 500 Fixed Hardware Style Installation and Operation User Manual (Publication 1747-6.21). Recommended surge suppression for switching 24V dc inductive loads is 1N4004 diode reverse wired across the load. (2) The continuous current per module must be limited so the module power does not exceed 1440 VA. (3) For dc voltage applications, the make/break ampere rating for relay contacts can be determined by dividing the 28 VA by the applied dc voltage. For example, 28 VA/48V dc = 0.58A. For dc voltage applications less than 14V, the make/break ratings for relay contacts cannot exceed 2A. RTB = Removable Terminal Block. Publication 1746-2.35 44 Discrete Input and Output Modules Operating Voltage Range (For ac operation: voltage is applied between L1 and L2.) (For dc operation: voltage applied is between +VDC and DC common.) 0 V 5V ac 0 V 5V dc 265V ac 125V dc Recommended Operating Range Operation Not Guaranteed Circuit Diagram VAC/VDC VAC/VDC OUT OUT 1746-OW4, OW8, OW16 1746-OX8 VDC/VAC OUT OUT Wiring Diagrams 1746-OW4 RELAY OUTPUT 1746-OW8 RELAY OUTPUT L1 or VAC–VDC L1 or VAC–VDC 1 +DC OUT 0 +DC OUT 0 V ac/dc V ac/dc OUT 1 OUT 1 OUT 2 CR OUT 3 CR L2 or –DC V ac/dc CR CR VAC–VDC 1 OUT 1 1 OUT 3 3 OUT 5 5 OUT 7 7 OUT 4 NOT USED OUT 5 CR PLC Publication 1746-2.35 L2 or –DC L1 or +DC V ac/dc OUT 6 CR OUT 7 CR L2 or –DC 1746-OX8 ISOLATED RELAY OUTPUT OUT0 0 OUT 2 VS0 L1 VAC–VDC 0 VS1 L1 VAC–VDC 1 2 OUT 4 4 OUT 6 6 CR CR VAC–VDC 2 11 OUT 8 10 OUT 11 OUT 10 13 OUT 13 12 15 OUT 12 OUT 15 14 17 OUT 14 16 VS2 VDC VAC–VDC 2 VS3 VDC VAC–VDC 3 L1 or +DC OUT 9 SLC CR NOT USED L2 or –DC CR OUT 3 VAC–VDC 2 1746-OW16 RELAY OUTPUT L1 or CR NOT USED NOT USED OUT NOT7 USED +DC OUT 2 NOT USED VS4 L1 VAC–VDC 4 VS5 L1 VAC–VDC 5 OUT 0 CR CR L2 or –DC VS6 VDC VAC–VDC 6 VS7 VDC VAC–VDC 7 VS0 L2 OUT 1 VS1 L2 OUT 2 VS2 DC COM OUT 3 CR VS3 DC COM CR VS4 L2 NOT USED OUT 4 V ac/dc CR OUT 5 VS5 L2 OUT 6 VS6 DC COM OUT 7 CR VS7 DC COM Discrete Input and Output Modules 45 Combination Modules (1746-IO4, -IO8, -IO12, -IO12DC) Specification Catalog Number 1746-IO4 1746-IO8 inputs: 120V ac outputs: ac/dc Relay Operating Voltage inputs: 85 to 132V ac at 47 to 63 Hz outputs: 5 to 265V ac at 47 to 63 Hz / 5 to 125V dc Points per Common 2 4 Points per Module 2 inputs / 2 outputs 4 inputs / 4 outputs Backplane 5V dc 0.030A 0.060A Current Draw 24V dc 0.025A 0.045A Continuous Current per 4.0A 8.0A Module Specification input same as 1746-IA4 Reference output same as 1746-OW4 1746-IO12 (RTB) 1746-IO12DC (RTB) inputs: 24V dc outputs: ac/dc Relay inputs: 10 to 30V dc sinking 6 6 inputs / 6 outputs 0.090A 0.070A 8.0A 6 6 inputs / 6 outputs 0.080A 0.060A 8.0A Voltage Category input same as 1746-IA16 output same as 1746-OW16 RTB = Removable Terminal Block. On/Off-State Voltage Range (AC Inputs) 0V ac + IN 85V ac 30V ac Off State Input State Not Guaranteed 132V ac On State – COM (Measure voltage from common terminal to input terminal.) On/Off-State Voltage Range (DC Inputs) 5V dc 0V dc + IN Off State 30V dc On State Input State Not Guaranteed – COM 10V dc (Measure voltage from common terminal to input terminal.) Operating Voltage Range (AC/DC Relay Outputs) (For ac operation: voltage is applied between L1 and L2.) (For dc operation: voltage is applied between +VDC and DC common.) 0 V 5V ac 0 V 5V dc 265V ac 125V dc Recommended Operating Range Operation Not Guaranteed Publication 1746-2.35 46 Discrete Input and Output Modules Circuit and Wiring Diagrams 270 1870 VAC/VDC AC COM 261 1µF V ac Input 1M OUT Relay Output 0.3µF IN 270 1870 1µF OUT 261 1M 3K IN 0.3µF 0.1µF IN 560 V dc Input 3K IN 0.1µF 560 DC COM 1746-IO4 100/120V ac INPUT – RELAY OUTPUT L1 or +DC VAC–VDC OUT 0 OUT 1 1746-IO8 100/120V ac INPUT – RELAY OUTPUT L1 or V ac/dc OUT 0 V ac/dc L2 or –DC CR OUT 1 NOT USED NOT USED L1 L1 IN 0 NOT USED OUT 7 AC COM OUT 3 CR IN 3 OUT 7 AC COM L2 1746-IO12DC 24V dc INPUT – RELAY OUTPUT L1 or +DC VAC–VDC VAC–VDC OUT 0 OUT 0 OUT 1 OUT 1 OUT 2 V ac OUT 2 V ac/dc OUT 3 OUT 4 CR OUT 5 L2 or –DC NOT USED L1 OUT 3 OUT 4 CR CR OUT 5 L2 or –DC NOT USED IN 0 IN 1 IN 3 IN 4 IN 2 10–30V dc IN 5 NOT USED Publication 1746-2.35 IN 0 IN 1 IN 2 L2 NOT USED +DC NOT USED 100/120 V ac L2 or –DC IN 2 1746-IO12 100/120V ac INPUT – RELAY OUTPUT L1 or +DC CR IN 1 100/120 V ac NOT USED L2 OUT 2 IN 0 IN 1 100/120 V ac +DC VAC–VDC IN 3 IN 4 IN 5 NOT USED AC COM NOT USED –DC NOT USED DC COM CR Discrete Input and Output Modules 47 Fixed I/O Chassis and Module Compatibility 7KHIROORZLQJFKDUWGHSLFWVWKHUDQJHRIFXUUHQWFRPELQDWLRQVVXSSRUWHGE\ WKHIL[HG,2H[SDQVLRQFKDVVLV7RXVHLW\RXPXVWILUVWGHWHUPLQHWKH EDFNSODQHFXUUHQWGUDZDQGRSHUDWLQJYROWDJHIRUERWKRIWKHPRGXOHV\RX SODQWRXVHLQWKHFKDVVLV<RXFDQJHWWKHVHVSHFLILFDWLRQVIURPWKH3RZHU 6XSSO\/RDGLQJWDEOHRQSDJH 1H[WSORWHDFKRIWKHFXUUHQWVRQWKHFKDUWEHORZ,IWKHSRLQWRILQWHUVHFWLRQ IDOOVZLWKLQWKHRSHUDWLQJUHJLRQ\RXUFRPELQDWLRQLVYDOLG,IQRW\RXU FRPELQDWLRQFDQQRWEHXVHGLQDVORWIL[HG,2FKDVVLV Example: Plot IN16 and NIO4V IN16 = 0.085A at 5V dc and 0A at 24V dc. NIO4V = 0.055A at 5V dc and 0.115A at 24V dc OA16 and IA16 (0, 455) 450 400 350 Current (mA) at 5V dc 1. Add current draws of both modules at 5V dc to get 0.14A (140 mA). 2. Plot this point on the chart at the right. (140 mA at 5V dc). 3. Add current draws of both modules at 24V dc to get 0.115A (115 mA). 4. Plot current draw at 24V dc (115 mA at 24V dc). 5. Note the point of intersection on the chart (marked x). This combination falls within the valid operating region for your fixed I/O chassis. 300 OW16 and IA16 (180, 255) 250 200 150 Plotted from the Example shown at the left. x 100 50 50 100 150 200 Current (mA) at 24V dc Important: 7KH12,DQG129DQDORJRXWSXWPRGXOHVPD\ UHTXLUHDQH[WHUQDOSRZHUVXSSO\5HIHUWR\RXUDQDORJPRGXOH XVHU·VPDQXDO Important: 7KHUHDUHFHUWDLQFRQGLWLRQVWKDWDIIHFWWKHFRPSDWLELOLW\ FKDUDFWHULVWLFVRIWKH%$6,&PRGXOH%$6DQGWKH '+56&PRGXOH.( :KHQ\RXXVHWKH%$6PRGXOHRUWKH.(PRGXOHWRVXSSO\ SRZHUWRD$,&/LQN&RXSOHUWKH/LQN&RXSOHUGUDZVLWV SRZHUWKURXJKWKHPRGXOH7KHKLJKHUFXUUHQWGUDZQE\WKH$,& DW9GFLVFDOFXODWHGDQGUHFRUGHGLQWKHWDEOHVIRUWKHPRGXOHV LGHQWLILHGDV%$6Q%$6QHWZRUNHGRU.(Q.(QHWZRUNHG 0DNHVXUHWRFKHFNWKHFXUUHQWGUDZYDOXHVIRUWKHVHPRGXOHVLI \RXUDSSOLFDWLRQXVHVWKH%$6RU.(PRGXOHLQWKLVZD\ Publication 1746-2.35 48 Discrete Input and Output Modules Power Supply Loading Hardware Components Catalog Number Maximum Current at 5V dc (Amps) Discrete Input 1746-IA4 0.035 Modules 1746-IA8 0.050 1746-IA16 0.085 1746-IB8 0.050 1746-IB16 0.085 1746-IB32 0.050 1746-IC16 0.085 1746-IG16 0.140 1746-IH16 0.085 1746-IM4 0.035 1746-IM8 0.050 1746-IM16 0.085 1746-IN16 0.085 1746-ITB16 0.085 1746-ITV16 0.085 1746-IV8 0.050 1746-IV16 0.085 1746-IV32 0.050 Discrete Input and 1746-IO4 0.030 Output Modules 1746-IO8 0.060 1746-IO12 0.090 1746-IO12DC 0.080 Publication 1746-2.35 Maximum Current at 24V dc (Amps) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.025 0.045 0.070 0.060 Hardware Component Discrete Output Modules Catalog Number Maximum Current at 5V dc (Amps) 1746-OA8 0.185 1746-OA16 0.370 1746-OAP12 0.370 1746-OB6EI 0.046 1746-OB8 0.135 1746-OB16 0.280 1746-OB16E 0.135 1746-OB32 0.190 1746-OB32E 0.190 1746-OBP8 0.135 1746-OBP16 0.250 1746-OG16 0.180 1746-OV8 0.135 1746-OV16 0.270 1746-OV32 0.190 1746-OVP16 0.250 1746-OW4 0.045 1746-OW8 0.085 1746-OW16 0.170 1746-OX8 0.085 Maximum Current at 24V dc (Amps) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.045 0.090 0.180 0.090 Discrete Input and Output Modules 49 7KHWDEOHEHORZOLVWVWKHSRZHUGLVVLSDWLRQIRUWKHGLVFUHWH,2PRGXOHV RSHUDWLQJDWQRPLQDOYROWDJH7KHIROORZLQJWHUPVDUHXVHGLQWKH3RZHU 'LVVLSDWLRQWDEOH Discrete I/O Power Dissipation Watts per Point The heat dissipation that can occur in each field wiring point when energized at nominal voltage. Minimum Watts The amount of heat dissipation that can occur when there is no field power present. Total Watts The watts per point plus the minimum watts (with all points energized). )RUH[DPSOHVRQFDOFXODWLQJV\VWHPKHDWGLVVLSDWLRQUHIHUWRWKH6/& 0RGXODU+DUGZDUH6W\OH,QVWDOODWLRQDQG2SHUDWLRQ8VHU0DQXDO3XEOLFDWLRQ RUWKH6/&)L[HG+DUGZDUH6W\OH,QVWDOODWLRQDQG2SHUDWLRQ8VHU 0DQXDO3XEOLFDWLRQ Power Dissipation Catalog Number 1746-IA4 1746-IA8 1746-IA16 1746-IB8 1746-IB16 1746-IB32 1746-IC16 1746-IG16 1746-IH16 1746-IM4 1746-IM8 1746-IM16 1746-IN16 1746-ITB16 1746-ITV16 1746-IV8 1746-IV16 1746-IV32 Watts per Point 0.27 0.27 0.27 0.20 0.20 0.20 0.22 0.02 0.32 0.35 0.35 0.35 0.35 0.20 0.20 0.20 0.20 0.20 Minimum Watts 0.175 0.250 0.425 0.250 0.425 0.250 0.425 0.700 0.217 0.175 0.250 0.425 0.425 0.425 0.425 0.250 0.425 0.250 Total Watts Catalog Numbers 1.30 1746-OB6EI 2.40 1746-OB8 4.80 1746-OB16 1.90 1746-OB16E 3.60 1746-OB32 6.65 1746-OB32E 3.95 1746-OBP8 1.00 1746-OBP16 5.17 1746-OG16 1.60 1746-OV8 3.10 1746-OV16 6.00 1746-OV32 6.00 1746-OVP16 3.60 1746-OW4 3.60 1746-OW8 1.90 1746-OW16 3.60 1746-OX8 6.65 1746-IO4 1746-OA8 1.000 0.925 9.00 1746-IO8 1746-OA16 0.462 1.850 9.30 1746-IO12 1746-OAP12 1.000 1.850 10.85 1746-IO12DC Watts per Point 0.440 0.775 0.338 0.150 0.172 0.250 0.300 0.310 0.033 0.775 0.388 0.172 0.310 0.133 0.138 0.033 0.825 0.27 per input point 0.133 per output point 0.27 per input point 0.133 per output point 0.27 per input point 0.133 per output point 0.20 per input point 0.133 per output point Minimum Watts 0.230 0.675 1.40 0.675 0.950 0.95 0.675 1.250 0.900 0.675 1.400 0.950 1.250 1.310 2.590 5.170 2.590 0.75 Total Watts 2.90 6.90 7.60 3.07 6.45 8.95 3.08 6.26 1.50 6.90 7.60 6.45 6.26 1.90 3.70 5.70 8.60 1.60 1.38 3.00 2.13 4.60 1.84 3.90 Publication 1746-2.35 50 Environmental Specifications Discrete Input and Output Modules Operating Temperature 0°C to 60°C (32°F to 140°F)(1) Storage Temperature -40°C to 85°C (-40°F to 185°F) Operating Humidity 5% to 95% (non-condensing) Noise Immunity NEMA standard ICS 2-230 Vibration (Operating) Displacement 0.015 inch peak at 5 to 57 Hz. Acceleration 2.5Gs at 57 to 2000 Hz Shock (Operating) 30Gs (all modules except relay contact) 10Gs (relay contact modules, 1746-OW, -OX, I/O Combo) 1500 Volts Isolation(2) UL listed. CSA or C-UL approved as indicated by product markings. CE compliant for all applicable directives when product or packaging is marked. Hazardous Environment Class I, Division 2, Groups A, B, C, D Hazardous Environment Class(4) Certification(3)(4) (1) Exceptions are indicated with certain modules. (2) Electro-optical isolation between I/O terminals and control logic. (3) Some modules are not CE marked. See page 2. (4) All modules meet Class 1, Division 2 requirements for hazardous location. Some modules are rated Class 1, Division 2 by CSA only. See page 2. Accessories 7KHIROORZLQJDFFHVVRULHVDUHDYDLODEOHIRUXVHZLWKGLVFUHWH,2PRGXOHV Catalog Number Item 1746-N2 Modular chassis slot filler Publication 1746-2.35 1492-IFMxx Feed-through interface modules 1492-CABLExxxx • xxxx = 010H • xxxx = 025H • xxxx = 050H 1746-N3 Cables: • 1 m (3.3 ft.) • 2.5 m (8.2 ft.) • 5 m (16.4 ft.) Connector kit Description Helps prevent debris from entering the SLC enclosure that can cause shorts or improper operation. Connects electronic wiring (discrete I/O modules, particularly 16- and 32-point) to electric wiring (factory devices). Available with either 20 or 40 terminals. Connects directly to the 1492-IFMxx interface module and is available with a removable terminal block or a ready-to-wire free end. This kit allows you to create your own cable. It contains one female connector and 45 crimp contacts. Note: 32-point modules are shipped with one connector kit. Discrete Input and Output Modules Allen-Bradley Support 51 ,QWRGD\·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• • • • VDOHVDQGRUGHUVXSSRUW SURGXFWWHFKQLFDOWUDLQLQJ ZDUUDQW\VXSSRUW VXSSRUWVHUYLFHDJUHHPHQWV Publication 1746-2.35 3/&3/&3/&DQG3/&DUHUHJLVWHUHGWUDGHPDUNVRI5RFNZHOO$XWRPDWLRQ 6/&6/&6/&6/&6/&6/&'DWD+LJKZD\3OXV3DQHO9LHZDQG56/RJL[DUHDWUDGHPDUNVRI5RFNZHO Publication 1746-2.35 - July 1999 Supersedes Publication XXXX-X.X.X - Month Year O$XWRPDWLRQ PN XXXXXX-XX © 1999 Rockwell International Corporation. All rights reserved. Printed in the U.S.A.