Ubiquitous - Managing Diabetes Australia

Transcription

Ubiquitous - Managing Diabetes Australia
Ubiquitous
Insulin Pump
ANYDANA & ANYDANA Android
DANA Diabecare R
DANA
Remote System
Enables You to...
keep your privacy
You no longer have to take your insulin pump
out in order to deliver a bolus, since the DANA
Remote enables you to operate all of the pump
functions very discretely..
download data to your PC
have a moreÀH[LEOHOLIH
access via the internet
When required, your health-care provider can
adjust your pump settings using the Any DANA
software through a secure internet connection.
When enabled, your health-care professional
or guardian can adjust the pump settings for
children or disabled patients.
5 Colors
DANA Ubiquitous Insulin Pump System
Now, you can discretely deliver a bolus without
anyone noticing! You no longer need to hide out
of sight to administer a bolus in a public setting.
For instance, when in a meeting, in class or at
a restaurant - simply use the discrete DANA
remote control!
DANA Diabecare R
You can download all of the pump settings to
your PC and easily review the history in colorful
graphs and print reports. All data, including
access to pump history, glucose levels, daily total
dose, bolus and even glucose patterns can be
easily and quickly viewed.
New
ANYDANA
Android
Smart Phone
Smart Pump
Using a secure Bluetooth connection, the Any DANA Android application is now available for the DANA R remote system. If you
have an Android Smart phone, you can use your phone as a discrete remote control for your DANA R Insulin Pump.
ANYDANA
Any Where
Any Time
0RELOH0DQDJHUIRU$QGURLGLVQRZDYDLODEOH
Using a secure Bluetooth connection, the Any DANA Android application is now available for the
DANA R remote system.
If you have an Android Smart phone, you can use your phone as a discrete remote control for your
DANA R Insulin Pump.
ANYDANA Android
Intuitive User Interface
DANA Ubiquitous Insulin Pump System
ANYDANA
+
-
OK
Customized
Personal Treatment
Report System
+
OK
Features
ANYDANA Program is a simplified diabetes
Data Management System.
‡<RXQRZKDYHWKHSRZHUWRFRQWURODQGPDLQWDLQ\RXU
diabetes in the palm of your hand! With the use of your
Android smart phone, you can access your DANA insulin
pump, communicate results to your physician and keep
track of your pump settings.
‡)
LUVWO\GRZQORDG\RXU'$1$5LQVXOLQSXPSVHWWLQJVDQG
history to your PC. Log onto the Any DANA Application’s
secure web site and create your own personalized ID
and password. You can then upload your pump data to
the secure cyber database to share with your health-care
team!
‡7KH$Q\'$1$VRIWZDUHSURYLGHV\RXDQG\RXUSK\VLFLDQ
with an all-inclusive database to access all the insulin
pump’s settings, history, and data.
‡7KHRQOLQHVRIWZDUHRUJDQL]HVWKHGDWDLQWRHDVLO\
accessible reports consisting of charts, tables and graphs.
‡3K\VLFLDQVFDQHDVLO\LQVWDOOWKH$Q\'$1$VRIWZDUHRQWR
a PC or laptop to gain quick and convenient access to their
patient’s data through the web-based Any DANA program.
Detailed reports track all the pump settings and history
from a web-based remote location, helping to optimize
treatment.
DANA
Insulin
Pump
ANYDANA
DANA Ubiquitous Insulin Pump System
DANA
Manager
Smart
Phone
DANA
Android
DANA Diabecare IISG
Smart Hybrid Insulin Pump
DANA
Insulin Pump
DANA
Diabecare IISG
Blood Glucose
The only insulin pump with an Integrated glucose meter
,QDGGLWLRQWRWKH6PDUW(DV\IHDWXUHVRI'$1$LQVXOLQSXPSVWKH,,6*LQWHJUDWHVDJOXFRVHPRQLWRUZKLFKQRW
only makes it the smallest, but also the only hybrid insulin pump available. You can customize your meal bolus
according to your carbohydrate intake and your current glucose levels. You can have the peace of mind of being
DEOHWRDGGDFRUUHFWLRQDOEROXVWRKHOSFRUUHFWHOHYDWHGEORRGJOXFRVHOHYHOV7KLVK\EULGLQVXOLQSXPSKDVD
complete integrated record system which keeps track of the patients’ glucose levels, carbohydrate intake, and
insulin delivery.
All In One
Small, Lightweight, Easy to Use Devices!
One Step
Simplify your diabetes management
Measurement
Freedom
Recording
You no longer need to carry a
glucose meter, log book, insulin
vials or syringes
Calculation
Control
Dose Adjusting
Insulin Infusion
7KH,,6*DOORZV\RXWRWDLORU\RXU
insulin dose according to your
glucose measurements
BOLUS FEATURES
SUPPLEMENTARY FEATURES
‡%ROXV,QFUHPHQWVRUXQLWV
‡XQLW%ROXV'XUDWLRQVHFRQGV
‡$XGLEOH
‡([WHQGHG%ROXVPLQXWHVKRXUV
‡'XDO3DWWHUQ%ROXV
‡&DUER%ROXV&DOFXODWLRQ3URJUDP
‡'RVH$XWR&RQ¿JXUDWLRQ
‡%XWWRQ6FUROO
‡/DQJXDJHV6XSSRUWHG
$UDELF&KLQHVH&]HFK'DQLVK'XWFK(QJOLVK
)UHQFK*HUPDQ+HEUHZ+LQGL+XQJDULDQ,WDOLDQ
Korean, Latvian, Lithuanian, Norwegian, Polish,
Portuguese, Russian, Slovenian, Spanish, Swedish,
7XUNLVK
BASAL FEATURES
‡3URJUDP'RVDJHXQLWKU
‡5DWHV3HU3UR¿OH%DVDO5DWHV
‡7HPSRUDU\%DVDOKUKUV
‡1XPEHURI3UR¿OHV
‡,QVXOLQ&DSDFLW\XQLWVFF
‡0HPRU\5HFDOO%ROXV3ULPH'DLO\
7RWDOV&DUERK\GUDWHDQG%ORRG*OXFRVH
‡$YHUDJH%DWWHU\/LIH:HHNV'HSHQGVXSRQ
LQVXOLQGRVDJH
‡,3;UDWH
SAFETY FEATURES
CUSTOMIZABLE FEATURES FOR
INDIVIDUALS INCLUDING PROFESSIONAL
CARE GIVERS
‡$XGLEOHUHPLQGHUVIRUWHVWLQJEORRGVXJDU
levels after bolus
‡%ROXV)UHTXHQF\5HVWULFWLRQ
‡3UHVHWWLQJRIGHIDXOWEROXVHV
‡3,1SURJUDPPLQJIRUKHDOWKFDUHSURIHVVLRQDO
DQGRUFDUHJLYHUV
+\EULGWHFKQRORJ\RIWKH'$1$,,6*DOORZV\RXWRWDNHFRQWURORI\RXUEORRG
JOXFRVHDQGJLYHV\RXIUHHGRPWRHQMR\OLIH
DANA Ubiquitous Insulin Pump System
‡%XWWRQ/RFNPRGHWRSUHYHQWXQLQWHQGHGRSHUDWLRQ
‡$ODUP/RZ%DWWHU\/RZUHVHUYRLU2FFOXVLRQ
‡)DLOVDIH)XQFWLRQ
‡%ROXV)UHTXHQF\5HVWULFWLRQ
‡$FWLYH,QVXOLQ0RQLWRULQJ
‡6DPSOHື, Capillary Whole Blood
‡7LPHVHF
‡5DQJHWRPJG/WRPPRO/
‡&DOLEUDWLRQ3ODVPDHTXLYDOHQW
‡$VVD\0HWKRG(OHFWURFKHPLFDO
‡6WULS'$1$%ORRG*OXFRVH6WULS
DANA Diabecare IISG
MISCELLANEOUS FEATURES
BLOOD GLUCOSE MEASUREMENT
DANA Diabecare IIS
Smart Insulin Pump
When Considering Insulin Pump Therapy,
Ask This Question.
Is it REAL?
Reliable
33 years of
Insulin Pump Innovation
Used by patients in
more than
60 countries
Easy
Icon Based Interface,
Easy Access to
Smart Features
Multiple Languages
Supported
Affordable
Cost Effective
Light and Small
Only 65 grams
with a full 300unit
reservoir
and battery
'RFWRU¶VPRGH/LJKWZHLJKWDQG6PDOO/RZ0DLQWHQDQFH&RVW8VHU)ULHQGO\
:DWHUSURRI,3;6DIHW\6HWWLQJVDQG0HPRU\/RFNRXW0RGHIRU6DIHW\
&DUERK\GUDWH&RXQWLQJ3URJUDP*XLGHG0DQDJHPHQW6\VWHP6WURQJDQG'XUDEOH
DANA Diabecare IIS
‡%ROXV,QFUHPHQWVRUXQLWV
‡XQLW%ROXV'XUDWLRQVHFRQGV
‡$XGLEOH
‡([WHQGHG%ROXVPLQXWHVKRXUV
‡'XDO3DWWHUQ%ROXV
BASAL FEATURES
‡3URJUDP'RVDJHXQLWKU
‡5DWHV3HU3UR¿OH%DVDO5DWHV
‡7HPSRUDU\%DVDOKUKUV
‡1XPEHURI3UR¿OHV
MISCELLANEOUS FEATURES
‡,QVXOLQ&DSDFLW\XQLWVFF
‡0HPRU\5HFDOO%ROXV3ULPH'DLO\
7RWDOV&DUERK\GUDWHDQG%ORRG*OXFRVH
‡$YHUDJH%DWWHU\/LIH:HHNV'HSHQGVXSRQ
LQVXOLQGRVDJH
‡,3;UDWH:DWHUSURRI
SAFETY FEATURES
‡%XWWRQ/RFNPRGHWRSUHYHQWXQLQWHQGHGRSHUDWLRQ
‡$ODUP/RZ%DWWHU\/RZUHVHUYRLU2FFOXVLRQ
‡)DLOVDIH)XQFWLRQ
‡%ROXV)UHTXHQF\5HVWULFWLRQ
‡$FWLYH,QVXOLQ0RQLWRULQJ
SUPPLEMENTARY FEATURES
‡&DUER%ROXV&DOFXODWLRQ3URJUDP
‡'RVH$XWR&RQ¿JXUDWLRQ
‡%XWWRQ6FUROO
‡/DQJXDJHV6XSSRUWHG
$UDELF&KLQHVH&]HFK'DQLVK'XWFK(QJOLVK
)UHQFK*HUPDQ+HEUHZ+LQGL+XQJDULDQ,WDOLDQ
Korean, Latvian, Lithuanian, Norwegian, Polish,
Portuguese, Russian, Slovenian, Spanish, Swedish,
7XUNLVK
CUSTOMIZABLE FEATURES FOR
INDIVIDUALS INCLUDING PROFESSIONAL
CARE GIVERS
‡$XGLEOHUHPLQGHUVIRUWHVWLQJEORRGVXJDU
levels after bolus
‡%ROXV)UHTXHQF\5HVWULFWLRQ
‡3UHVHWWLQJRIGHIDXOWEROXVHV
‡3,1SURJUDPPLQJIRUKHDOWKFDUHSURIHVVLRQDO
DQGRUFDUHJLYHUV
DANA Ubiquitous Insulin Pump System
BOLUS FEATURES
%ORRG*OXFRVH0RQLWRULQJ6\VWHP
DANA Cheker
+LJKO\DFFXUDWHEORRGJOXFRVHPRQLWRULQJ
through advanced biosensor technology
DANA strip for DANA R pump is used.
Easy to use
‡Rapid test results in just 5 seconds
‡YDOXHPHPRU\ZLWKGDWHDQGWLPH
Convenient
‡6PDOOVDPSOHYROXPHXVLQJRQO\ື
‡$OWHQDWHVLWHWHVWLQJIURP¿QJHUWLSVSDOPVIRUHDUPVDQGWKLJKV
Reliable
‡3URYHQDFFXUDWHUHVXOWZLWKJOXFRVHVSHFL¿FPHWKRG
‡/RQJVKHOIOLIHRIPRQWKV
6SHFL¿FDWLRQV
7HVW
PJG/PPRO/
Sample Size
0LQLPXPື
7HVW7LPH
5 Seconds
7HVW6DPSOH
Fresh capillary whole blood
Calibration
Plasma-equivalent
Assay Method
Electrochemical
Battery Life
7HVWV
Memory
%ORRGJOXFRVHYDOXHV
Dimension
;;PP
Weight
J%DWWHU\LQFOXGHG
Operating Range
7HPSHUDWXUH
ଇ‫ٻ‬ദ
‫ڡ‬
5HODWLYH+XPLGLW\
+HPDWRFULW
Easy to use
Reliable
Accuracy
Pump Components
Infusion Sets
6RIW5HOHDVH2
Features
Catalog Number
Catalog Number
Soft cannula length
7RWDOWXELQJOHQJWK
6
PP
FP
6
PP
FP
6
PP
FP
6
PP
FP
6
PP
FP
6
PP
FP
6
PP
FP
6
PP
FP
6RIW5HOHDVH67
Features
Catalog Number
5LQJORFNPHFKDQLVP
$QJOHLQVHUWLRQ
1HHGOH7\SH
6HOIDGKHVLYHWDSH
Easy to connect and disconnect.
GHJUHH6WUDLJKWQHHGOH
7HIORQ*
$QFKRUVWKH6RIW5HOHDVH67WRWKHLQMHFWLRQVLWH
Catalog Number
Soft cannula length
7RWDOWXELQJOHQJWK
65
PP
FP
65
PP
PP
Catalog Number
Features
5LQJORFNPHFKDQLVP
$QJOHLQVHUWLRQ
1HHGOH7\SH
6HOIDGKHVLYHWDSH
Easy to connect and disconnect.
GHJUHH
6WDLQOHVVVWHHO*
Anchors the Easy Release to the injection site.
Catalog Number
Soft cannula length
7RWDOWXELQJOHQJWK
68 68 68 68
PP PP PP PP
FP FP FP FP
Easy Release II
Catalog Number
Features
5LQJORFNPHFKDQLVP
$QJOHLQVHUWLRQ
1HHGOH7\SH
6HOIDGKHVLYHWDSH
Easy to connect and disconnect.
GHJUHH
6WDLQOHVVVWHHO*
Anchors the Easy Release II to the injection site.
Catalog Number
Soft cannula length
7RWDOWXELQJOHQJWK
68 68 68 68
PP PP PP PP
FP FP FP FP
Superline ST
Catalog Number
Features
$QJOHLQVHUWLRQ
1HHGOH7\SH
6HOIDGKHVLYHWDSH
GHJUHH
6WDLQOHVVVWHHO*
$QFKRUVWKH6XSHUOLQH67WRWKHLQMHFWLRQVLWH
GGInserter R
Catalog Number
Soft cannula length
7RWDOWXELQJOHQJWK
GG,QVHUWHU67
68
PP
55cm
68
PP
55cm
68
PP
55cm
DANA Ubiquitous Insulin Pump System
Easy Release
'$1$&KHNHU,QIXVLRQ6HWV
7KH6HW7KDW6SLQV )UHHO\URWDWHVGHJUHHV(OLPLQDWHWKHQHHGWRORRNDWWKHVLWHWRFRQQHFWRUGLVFRQQHFW
increase site selection areas.
$QJOHLQVHUWLRQ
GHJUHH
1HHGOH7\SH
7HIORQ*
6HOI$GKHVLYHWDSH %
RG\KHDWDFWLYDWHGQHZWHFKQRORJ\WDSHUHDOO\VWLFNVZKHQZHW7UDQVOXFHQWWDSHPDWFKHV
natural skin tones and does not draw attention to site.
Smooth low profile dome shape won’t snag clothing.
/
RZGH[WHULW\RQHKDQGHG1HHGOH)UHHFRQQHFWRUHOLPLQDWHVQHHGOHVWLFNVDQGLVFRPIRUWDEOH
for big and little fingers.
33 Year-Ol
Since 1979
SOOIL History
1979
1983
1993
1995
1998
First Portable Insulin Pump
Portable Insulin Pump
Diabecare
Diabecare MINI
DANA Diabe
2011 EASD
1979 The first SOOIL insulin pump is clinically tested at Seoul National
University Hospital.
1980 SOOIL develops the first portable insulin pump suitable for
everyday use.
1981 SOOIL establishes Factory Registration for the manufacturing of
the SOOIL insulin pump.
2010 EASD
1981 SOOIL receives approval for the Diabecare 3 insulin pump from the
Korea Food and Drug Administration (KFDA).
3
1995 SOOIL obtains approval for the Diabecare MINI insulin pump
from the KFDA.
1995 SOOIL establishes a collaboration with the medical colleges of
Seoul National University and KonKuk University for Research and
Development.
2009 EASD
1998 SOOIL obtains approval for the DANA Diabecare 3 insulin pump
from the KFDA.
1999 SOOIL is certified by SGS ISO9001, EN46001, ISO13485, CE0120 for
worldwide sales.
2000 SOOIL receives FDA clearance for the DANA Diabecare 3 and
Superline insulin infusion set.
2008 EASD
2001 SOOIL develops the DANA Diabecare y II insulin pump.
2002
2007 EASD
SOOIL receives FDA clearance for the DANA Diabecare y II, SoftRelease-ST soft cannula set and Superline- Easy-Release
detachable Infusion set for marketing in the U.S.
d History
ecare
Only on Insulin Pump
2001
2006
2008
DANA Diabecare II
DANA Diabecare IIS DANA Diabecare R
2003 DANA Diabecare y II receives World-class Product Award from the
Korean Government.
2012 Any Dana Android Application
2012 6th Distributors Meeting
2005 SOOIL opens U.S. Subsidiary in San Diego, California.
2006 SOOIL obtains CE mark for the DANA Diabecare y IIS and the
product is launched in EU countries.
2006 SOOIL develops the IISG Smart-Hybrid Insulin pump which
combines the IIS technology with a glucose meter.
2007 US FDA clears DANA IIS insulin pump.
SOOIL obtains CE mark for DANA IISG insulin pump.
SOOIL hold 1st Distributors Meeting
2011 5th Distributors Meeting
2008 SOOIL obtains CE mark for DANA R insulin pump.
SOOIL hold 2nd Distributors Meeting
2009 SOOIL develops new user interface on DANA R insulin pump.
SOOIL hold 3rd Distributors Meeting
2010 4th Distributors Meeting
2010 SOOIL develops Any DANA.
SOOIL hold 4th Distributors Meeting
2011 SOOIL develops Any DANA for Windows Mobile.
SOOIL hold 5th Distributors Meeting
2012 SOOIL develops Any DANA for Android
2009 3rd Distributors Meeting
2008 2nd Distributors Meeting
iyTlzTXZG™Œ`
ANYDANA & ANYDANA Android
SOOIL Development Co., Ltd.
www.sooil.com
196-1, Dogok-dong Kangnam-gu, Seoul, KOREA 135-270
Tel:+82(2)3463-0041 Fax:+82(2)3463-7707 E-mail:sooil@sooil.com

Similar documents

Manual - Husqvarna Viking

Manual - Husqvarna Viking XVHUVHUYLFLQJDGMXVWPHQWVPHQWLRQHGLQWKHLQVWUXFWLRQPDQXDO ‡ 1HYHUGURSRULQVHUWDQ\REMHFWLQWRDQ\RSHQLQJ ‡ 'RQRWXVHRXWGRRUV ‡ 'RQRWRSHUDWHZKHUHDHURVRO VSUD\ SURGXFWVDUHEHL...

More information

600 series

600 series 0DOHDQG)HPDOH7UDQVLWLRQ'HYLFHV ) 0 DUHDYDLODEOH ZKHUHFKDQQHOUXQVDUHLQRSSRVLWHGLUHFWLRQVDQGWZRFKDQQHOV DUHVHWHLWKHUIHPDOHWRIHPDOHRUPDOHWRPDOH$IHPDOH WUDQVLWLRQ...

More information