BentoFix® X2 Brochure

Transcription

BentoFix® X2 Brochure
ADVANCED
SAFETY WITH
X
BENTOFIX®
The eXtra factor!
2n
p
frict roducti d Bento
o
ion
f
surf n line ix®
w
ace
coa ith
ting
Coated
BBA
cert
ifi
201
"Use cation
in w for Be
2
ater
2
ntof
also
0
p
ix
11
rest
NAU
ricti underg roofing ® X2 B
ng f
F
a
star E ASIA
low round c nd dam G 5300
ts
S
of m
onc
f
p
o
p
r
p
rodu with a dn. Bh
ro
etha rete
d.
ctio
B
ne g struc ofing
M
alay
n in entofi
t
as a
sia
Sela x®
nd r ures"
ngo
ado
r,
n.
201
IGS
1
2
0
Awa
10
rd
com in rec
1st
ogn
pan
B
y’s G ition
with entofi
CL i
of t
Engineers are always concerned with safety in design, and
add x® pr
nno
he
itio
vati
nal oductio
on
this
applies equally throughout all product sectors. Automocoa
ting n line
BBA
2
c
008
biles utilize air bags and advanced braking systems. Computer
500 ertific
200
0 fo
a
r "U tion fo
6
s
r
data can be backed up and saved by cloud servers. Food packDam e in W Bento
at
fi
p-pr
CE m
oofi erproo x® BFG
a
aging
utilizes multi-layer constructions to prevent contamination
rk
ng U fing
for
Ben ing imp
a
nde
rgro nd
tofi
l
and degradation.
x® ement
Stru
u
ctur nd
atio
es".
n
200
5
200
land Multip
The idea of safety and the final safety-improving element frequently
le e
3
fill
x
c
L
c
GCL
a
o
a
p
n
v
s
g
a
s an
seems simple, but the solution is always much more advanced. NAUE
t
time -term
d ex with Be ions o
s
f
tens
n
test of Ben ervice
Bentofix®
X coated geosynthetic clay liners (GCLs) represent the next stage
ive tofix®
li
ed u
t
test
p to ofix® G feing
CL
400
in GCL design and performance, and they offer a considerable increase in the
yea s
200
rs
BENTOFIX®X
gives you the
eXtra SAFETY
2
200
0
available factor of safety for GCLs. With the addition of a polyolefin polymer-
X
modifications to geosynthetic product design can be made to anticipate exactly
what the design engineer must anticipate: the challenges of a particular site.
From waterproofing in areas with radon gas present in the soil to applications with
low confining stress to situations with the threat of desiccation or root penetra-
8
er
rwat
nde mat
u
®
d
tofix ith san
Ben
w
First llation
a
inst st layer
a
ball
19
of
tion
ifica GCLs
t
r
e
®
ix
tC
DIB Bentof ill caps
ndf
a
l
an
erm
for G
tion, Bentofix® X coated enables the designer to specify a sustainability-
199
land
ours test
h
0
0
ep
40,0 cap cre ep nor
fill no cre tion
ed
riora
show re dete
b
i
f
97
increasing GCL barrier with a higher factor of safety and longer service life.
Geosynthetic clay liners are composite barrier materials, each component
of which plays an essential, easy-to-understand function.
6
199
®
How these components are selected and combined in the manufacturing
ix
ntof
n Be gth
o
n
n
e
io
r str
licat
Pub vs shea
l
pee lation
e
corr
5
199
process, however, truly determines the longevity and performance of the GCL.
Bentofix® X is a needle-punched GCL comprised of a uniform layer
4
uced
trod rket
n
i
s
a
L
® GC ralian m
t
tofix
Ben the Aus
to
199
of powder sodium bentonite that is encapsulated between a
s
GCL
fix® et
o
t
n
k
f Be
mar
ch o ican
Laun e Amer
h
in t
2
199
slit-film woven and a staple-fibre nonwoven geotextile. Powder
bentonite provides extraordinary swelling properties to immediately seal after contact with fresh water. The needle-punching
process - which NAUE invented in the 1980s and for which
1
f
on o
nati xtile
g
e
r
p
te
te im en geo erlaps
v
toni
Ben nonwo safe ov
for
fix®
ento
B
the
coating on the woven side of the GCL, Bentofix® X coated exemplifies how
Pub
l
on T ication
s
h
nee ermal of res
dleearc
pun Lock
h
che
d GC
Ls
199
it was awarded the International Geosynthetics Society’s
PE s
f HD
L
les o fix® GC
i
t
x
o
e
t
t
n
o
Ge in Be
used
highest honor, an IGS Award - firmly bonds the durable,
nonwoven layer to the bentonite core and greatly
0
increases the GCL’s frictional properties.
199
989
ix®
ntof
² Be airport
m
0
h
,00
750 n Munic
i
d
e
s
u
1
®
ix
ntof
f Be
o
e
us
First landfill
a
in
8
198
g
ntin
Inve edlee
of n GCLs
ched
u
p n
7
198
Every component is the architect of the success of Bentofix®
Slit-film
woven
Needle-punched
Secutex® nonwoven
Polyolefin
coating
Typical needle
for the needlepunching process
Sodium
bentonite
powder
Finally, the low-permeability polyolefin coating is firmly attached, without the need of bonding with an additional
adhesion, e.g. glue, to the slit-film woven on Bentofix® X GCL types. This side can actually be installed up or down, depending
on the application’s need. The coating increases the GCL’s gas barrier performance, reduces root penetration, prevents bentonite
pipe under high-water gradients, decreases desiccation risk, guards against ion exchange, etc.
IN SHORT: Design safety increases, and service lives are extended.
1.
3.
2.
4.
1. The slit-film woven is the base for
the bentonite core and the fibre
reinforcement.
3. The nonwoven geotextile provides the
bentonite encapsulation and the high
internal friction characteristics.
2. High-swelling powder sodium bentonite as
the barrier component is uniformly distributed
over the slit-film woven.
4. The needle-punching (over 2 million fibres/m²)
with the fibres firmly bond these layers for a
long, sustainable service life.
5.
5. The polyolefin polymer-coated woven
provides resistance and a durable barrier.
Bentofix® X is a polyolefin polymer-coated GCL and exemplifies how modifications to GCL product design can be made to anticipate the
special challenges of a particular site. The woven fabric is coated with a low-permeability polymeric polyolefin coating to achieve
an immediate barrier prior to hydration and give the GCL several add-on values. Bentofix® X is an advance for GCLs in some specific
applications, such as waterproofing, oil and gas tank farms, landfill capping and cover systems or where high hydraulic gradients are present.
NAUE GmbH & Co. KG
Gewerbestrasse 2
32339 Espelkamp-Fiestel
Germany
Phone
Fax
E-Mail
Internet
+49 5743 41-0
+49 5743 41-240
info@naue.com
www.naue.com
NAUE Asia Sdn. Bhd.
No. 18-M, Jalan SR 1/9 Seksyen 9,
Serdang Raya · 43300 Seri Kembangan
Selangor · Malaysia
®
and Bentofix® are registered trademarks of NAUE GmbH & Co. KG in various countries.
The information contained herein is the best to our knowledge, true and accurate. There is no implied or expressed warranty.
© 2012 by NAUE GmbH & Co. KG, Espelkamp-Fiestel, Germany · All rights reserved. · No. 238 · Status 21.08.2012
Phone
Fax
E-Mail
Internet
+60 3 89452927
+60 3 89489927
asia@naue.com
www.naue.com