losangeles-ca
Transcription
losangeles-ca
TECHNICAL SPECIFICATIONS Table of Contents Contact Information General Information Location Parking, Arrivals, Red Carpets Rental Rates and Labor Rates Fire Safety Telecommunications Front of House Information Ticket Capacities Seating Configurations Ushers, Ticket Takers, and Security Merchandising, Food, and Catering Back of House Information Physical Dimensions, Load Ratings/Construction Rigging Systems Dock/Access Production Offices/Dressing Rooms Electrical (Power) Feeds, Performance Lighting System Lighting Inventory Performance Sound System Headset (Clear-com) System Hearing Assistance Package House Drapery Package House Rigging Equipment Rear-stage Gantry System, Performance Haze, etc. Wardrobe/Hair and Makeup Other Technical Equipment Unions Contact Cheat Sheet Additional Attachments Stage Level Layout, GP 1.5 Bottom Level Room Layout, GP 1.0 Thumbnail Centerline Section Lineset schedule of House Drapery Plot Seating Chart, all levels Seating Chart, Orchestra Seating Chart, Parterre Seating Chart, Mezzanine 1 Seating Chart, Mezzanine 2 Seating Chart, Mezzanine 3 2 2 2 3 3 3 3 3 3 3 4 4 5 5 6 7 8 10 10 10 11 11 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 Technical Specifications for Incoming Shows Kodak THEATRE Rev. Date: 2/06 Contact Information: Main number (reception) (323) 308-6300 Main fax (323) 308-6381 Box Office (323) 308-6363 Box Office fax (323) 308-6364 web site http://www.kodaktheatre.com Jay Thomas, VP/General Manager (323) 308-6382 jthomas@ kodaktheatre.com Laura Patterson, Technical Director (323) 308-6355 lpatterson@kodaktheatre.com Mike Fairman, Asst Tech Director (323) 308-6384 mfairman@kodaktheatre.com Sergio Ruezga, Dir of Events (323) 308-6375 sruezga@kodaktheatre.com Miranda Garza, Box Office Treasurer (323) 308-6367 mgarza@kodaktheatre.com Joe Orenals, Asst Box Office Treasurer(323) 308-6387 mgarza@kodaktheatre.com Russell Malcomb, Operations Mgr (323) 308-6350 rmalcomb@kodaktheatre.com Robby Fiely, Finance Mgr (323) 308-6386 rfiely@kodaktheatre.com Rowena Adalid, Marketing Mgr (323) 308-6379 radalid@kodaktheatre.com Rachelle Granillo, Admin. Support (323) 308-6380 rgranillo@kodaktheatre.com Katie Hudson, Group Sales Manager (323) 308-6333 khudson@kodaktheatre.com Event Security (323) 308-6344 Marcie Morfin, Receptionist (323) 308-6389 mmorfin@kodaktheatre.com Jason Carey, WGP Bar Mgr (323) 491-1263 kodakbeverage@wolfgangpuck.com Wolfgang Puck Catering & Events (323) 491-1250 www.wolfgangpuck.com Hollywood & Highland (323) 817-0220 www.hollywoodandhighland.com General Information: Location The physical and shipping address of the theatre is: Kodak THEATRE 6801 Hollywood Blvd, Suite 180 Hollywood, CA 90028 The Kodak THEATRE is located in the Hollywood & Highland retail, dining, and entertainment complex. The loading dock, which loads directly into the back of the stage, is accessed off of Orange Street, between Hollywood and Franklin. Parking, Arrivals, Red Carpets The Kodak THEATRE does not own or control any parking for the audience or production personnel, nor does the theatre validate at any area parking lots. The parking garage of the Hollywood & Highland complex is the nearest parking to the theatre and can be entered off of Highland or Orange Street. The garage maximum is $10/day. The Highland entrance is open 24 hrs/day and the Orange Street entrance is only open during the complex’s operating hours. Contact Theatre Management for additional information regarding parking options in the area or for information regarding VIP arrivals and/or red carpet arrivals. Also be aware that the Kodak THEATRE loading dock and the red carpet entrance to the theatre is a shared space with the Hollywood & Highland retail complex, so those needs must be coordinated with Theatre Management. 2 Technical Specifications for Incoming Shows Kodak THEATRE Rev. Date: 2/06 Rental Rates and Labor Rates Please contact Kodak THEATRE management for information regarding rental rates for the facility or equipment use therein. Also, please contact theater management for the labor rates and policies of the facility. Fire Safety Kodak THEATRE complies with all applicable city, state, and federal regulations regarding fire safety. All on-stage softgoods must have a State of California Certificate of Flame Resistance indicating that it has been adequately treated. Please note that certificates from other states are not acceptable. Any plans to block or change exit pathways and aisles for the public must be approved by the theatre and the city as well as all alternate seating plans. Telecommunications Kodak THEATRE has a variety of phone options depending on the size and complexity of the production. Contact Theatre Management for details. Front of House Information Ticket Capacities Orchestra VIP Orchestra Parterre Mezzanine 1 Mezzanine 2 Mezzanine 3 Total Distance from stage 81 578 801 638 529 773 22' – 55' 68' – 111' 83' – 120' 96' – 124' 121' – 153' 3,400 Seating Configurations The Orchestra Pit/Stage Apron area can be re-configured in a variety of ways depending on the needs of the production. Coordinate with Theatre Management before putting Orchestra rows AA and BB on sale. See the attached pages of seating charts for more information. Ushers, Ticket Takers, and Security Please contact Theatre Management for information regarding ushers and ticket takers. The Kodak THEATRE uses in-house usher, ticket-taker, and security staffs. Merchandise, Food, and Catering Wolfgang Puck Catering and Events is the exclusive caterer for the Kodak THEATRE. No outside food, front of house or backstage, is allowed in the theatre without permission from Theatre Management. All catering orders, including backstage coffee, must be placed one week in advance. Please contact the Theatre Management for more information regarding merchandising and catering. 3 Technical Specifications for Incoming Shows Kodak THEATRE Back of House Information Physical Dimensions: Stage, Grids, and Orchestra Proscenium: Overall stage area: Stage deck: SR side stage: Trap room area: Rear stage: Throw distance from booth: Stage to house floor: Grid height: Forestage grid: Gallery height: Trap room height: Rev. Date: 2/06 35' h x 63' w (adjustable to 43'w) 113' w x 60' d 109' x 58' d 27' w x 60' d x 35' h 40' w x 29'-5" d (stage deck does not have traps) 78' w x 15' d x 35' h ≈110' to 10' above stage floor at PL (8° angle) 3'-5" 89'-6" above stage floor 16' deep channel grid, 80' above stage floor 35' clear below 14'-6" to finished stage floor Orchestra pit capacity: Orchestra pit area: Orchestra pit lift size: Orchestra pit lift/apron travel: Orchestra pit lift capacity: Media pit (house mix pos.): Über media pit, 4 rows removed: Media pit lift: A/V Booth (back of 1st Mezz): Load Ratings/Construction Stage floor loading: Stage floor construction: Grid(s) construction: Forestage rigging beams: Rigging Systems Counterweight sets: Arbor capacity: Flying heights: Fly rail: Pin rails: Motorized sets: Capstan winch: Motor control stations: Access to grid(s): 70 players 70' x varies (850 sq ft) 65'w x 1' - 9' d, (460 sq. ft) stage level to 10' below 28,000 lbs dynamic; 78,000 lbs static 28'-6" w x 7'-9" d 28'-6"' w x 20'-5" d 4'-7" d x 7'-7" w 43' w x 11' d 150 lbs./sf uniform load, 7,000 lb concentrated load capacity ¼" masonite over plywood on 2x4 sleepers. traditional 3" channel grid underhung loft blocks, 1 SR ups grid hatch W10x22 in a 8' o.c. x 6'-3" o.c. grid (76) manual sets, 86' wide (picks @ 12' o.c.) ladder (truss) battens, 1-1/2" sch. 10 pipe 2,150 lbs. above pipe weight 3'-3" from stage floor to 82'-6" SL Gallery or SL stage level SL and SR Galleries (4) UPS/DS tabsets, 500 lb capacity ea (1) at lower rail, 1,500 lb capacity (10) on stage grid; (12) on forestage grid stairs USR, ladder USL, elevator or stair off SL 4 Technical Specifications for Incoming Shows Kodak THEATRE Rev. Date: 2/06 Dock/Doors/Access All truck parking, bus parking, and shore power needs should be coordinated with the theater. Some parking may be available in Orange Court on a case by case basis. All dock needs must be discussed in advance so that both the production and H&H's delivery and parking needs are met. 4' ± 1" off of road, leads to stage right via rolling doors (3) useable truck bays, but use must be coordinated w/ H&H Main doors: 12'-3"w x 13'-7"h is the max opening of the rolling doors leading to the stage. Stage Elephant door: 19'w x 20'h door opens to a dock level ledge behind the stage SR Elephant door: 15'-11"w x 13'-9"h SR Scene dock (breezeway): 29' x 77' (clear height 11') Artist access: SL back stage drive-up access, SR dock access Private side entrance in Lobby 1 (from valet parking) Elevators from parking garage Main dock: Production Offices/Dressing Rooms All of the dressing rooms (DR 1, DR 2, DR 6, DR 7/8, etc.) have at least one bathroom with a sink, mirror, toilet, and shower. The bathrooms are in addition to the room sizes listed. Every dressing room also has one chair and one makeup mirror per occupant. Musician's rooms and Production offices are furnished with tables and chairs by request. Total dressing room capacity in the lower level is 74 people, not including the Production Offices or Musician's rooms. Stage Level (Star Dressing Rooms): DR 1 often used for headliners or as a band/green room ≈25' x 25', kitchenette area, 1 digital & 4 analog lines available DR 2 1 – 2 person, ≈10' x 11', 1 digital phone line available DR 3 1 – 2 person, ≈10' x 11', 1 digital phone line available DR 4 1 – 2 person, ≈10' x 12', 1 analog phone line available DR 5 1 – 2 person, ≈10' x 12', 1 analog phone line available Stage Manager's Office, ≈14' x 12', 3 analog and 1 digital phone line available See next page for Lower Level Dressing Rooms. 5 Technical Specifications for Incoming Shows Kodak THEATRE Rev. Date: 2/06 Lower Level Dressing Rooms listed by proximity to the stage: DR 6 15 person, ≈13' x 17', 1 analog line available DR 7/8 8 person, ≈13' x 15', 1 analog line available DR 16 8 person, ≈12' x 16', 1 analog line available DR 9 DR 10 DR 15 4 person, ≈11' x 12', no phones available 4 person, ≈11' x 12', no phones available 12 person, ≈9'' x 27', 1 analog line available DR 11/12 DR 13 DR 14 9 person, ≈18' x 14', no phones available 10 person, ≈21' x 12', no phones available 4 person, ≈10' x 12', no phones available Musician's B ≈12' x 18', bare room, no bathroom 1 digital and 1 analog line available Musician's C ≈12' x 18', bare room, no bathroom 1 digital and 1 analog line available Lower Level Production Spaces: Lounge, ≈35' x 30', + kitchen (usually used for crew/cast feeds) 2 digital and 2 analog lines available Rehearsal room, ≈40' x 30' 1 digital and 1 analog line available Wardrobe room Wardrobe use only, ≈22' x 39' Conference Room Not available for production use Electrical (Power) Feeds All company switches rated for 400A or less have female cam-type connectors, compatible w/ Cam-Lok E1016. Power feeds, Company Switches Stage: (2) 400A, 3∅, 5 wire, 120/208, DSR SR Gallery: (6) 400A, 3∅, 5 wire, 120/208 (1) 800A, 3∅, 5 wire, 120/208 Grid: (1) 100A, 3∅, 5 wire, 120/208 Forestage Grid: (3) 200A, 3∅, 5 wire, 120/208 Scene dock: (1) 800A, 3∅, 5 wire, 480/277 Rehearsal Hall: (1) 200A, 3∅, 5 wire, 120/208 6 Technical Specifications for Incoming Shows Kodak THEATRE Rev. Date: 2/06 Audio (isolated ground) power feeds, Company Switches Stage: (1) 200A, 3∅, 5 wire, 120/208, UP SR Trap Room: (2) 200A, 3∅, 5 wire, 120/208 Media sub-pit: (1) 200A, 3∅, 5 wire, 120/208 Rehearsal hall: (1) 100A, 3∅, 5 wire, 120/208 Throughout theater (17) 100A, 3∅, 5 wire, 120/208 buss ducts Performance Lighting System There are no permanent electrified battens on stage. The theater maintains a house plot (hung, not focused, no gel) on stage and on the FOH positions which must be restored at the production's expense if it is modified. Dimmers: (720) 2.4K, (48) 6K, ETC Dry circuits: (96) circuits w/ breakers for dimmer rack tie-in SR Gallery. Receptacles are on forestage grid. FOH hang positions: (3) balcony rail pipes Tiara catwalk (cove) & box positions Stage hang positions: 76 manual sets, light ladders are available to hang. All electrics are powered via Veam (Socapex) cables run from the SR Gallery. THERE ARE NO RACEWAYS. Cable networks: Lighting Inventory Follow spots: Lighting console: Lighting Inventory: Extensive network of cable tray on the lower level. Extensive network of cable penetrations throughout theater. Cable tunnels to media trailer locations (contact Kodak THEATRE management for details). Cable troughs along all three balcony positions. 4 cable risers on each side of house, lower level to catwalk (4) 2,000W Xenon Lycian 1290XLT (must stay in booth) Obsession II SPS 1500 (446) Source Four Ellipsoidals, varying angles (575W) (78) 8" – 10" Fresnels (1000 – 2000W) (120) Source Four Pars (575W) (80) Focusing Cyc lights ("palace" lights) w/ 12 hanging brackets (4 units each) For more details on the complete inventory, contact Kodak THEATRE management. Gel/gobo inventory: No gel or gobos available A and B Pattern holders 7 Technical Specifications for Incoming Shows Kodak THEATRE Rev. Date: 2/06 Performance Sound System The main PA consists of two powered Meyers speaker clusters hung SR and SL. In addition to the main clusters, the house is also equipped with a full set of front fills (Meyer M1Ds) and delay speakers for the balconies and boxes. There are Neutrik NL4 speaker dry lines throughout the house, all accessible via a patch bay in the Patch Room, located in the lower level. These NL4 dry lines include surround sound points on all levels of the seating chamber and at each point there is a section of Unistrut channel recessed in the wall for use as a speaker mount. There is a 4-speaker Portable PA system available, as well, for use in auxiliary spaces (see specs below). If the speaker clusters or FOH console must be removed for a production, the production must bear the labor cost of restoring them to their standard positions. The Kodak THEATRE does not own a monitor sound system (however, 4 UPJ speakers are available for foldback). The following lists show the major in-house components of the Kodak THEATRE sound system: House Tie-Lines In addition to the Neutrik NL4 dry lines, the theatre is equipped with patch points for XLR, BNC, Cat 5 and Fiber Optics. The patch points are in various locations throughout the building and all terminate in the patch room. All patch points are home runs (i.e., XLR ends in XLR, BNC in BNC, etc.). There are no TT or ¼” patch bays at the theatre. The individual patch runs do not share a common ground or common shield – each patch point has its own individual ground run from point to point. Significant locations of the patch boxes throughout the theater include: o (2) patch boxes in the FOH media pit include a total of (124) XLR tie-lines, (20) CAT 5 tie-lines, (4) BNC tie-lins, (4) fiber optic patch points. o (4) patch boxes on-stage in each corner. Each box consists of no less than (28) XLR tie-lines and a number of CAT 5 dry lines to the patch room. The DSL and DSR boxes also include (2) BNC video dry lines, (8) NL4 drylines, and (4) fiber-optic patch points. There are also (2) BNC dry lines UPS center. o Both of the 4th Floor loading galleries have (2) XLR dry-lines and (2) BNC dry lines. o A/V Booth has (2) patch boxes with a total (4) BNCs total, (40) XLR (4) CAT 5 o The center face of the Mezzanine 1 rail has (8) BNC dry lines, one of which is dedicated to the house video camera, as well as (10) XLRs. Each side of each Mezzanine rail has (1) XLR dry line. o The center face of Mezzanine 2 rail has (10) XLRs and (1) BNC dry line. o The center face of Mezzanine 3 rail has (1) XLR dry line. 8 Technical Specifications for Incoming Shows Kodak THEATRE Rev. Date: 2/06 FOH Console The AMEK Recall RN console has 56 channels, 50 mono channels and 6 stereo. It features Rupert Neve designed pre-amps and Eqs in each channel. It has Recall functions with a Showtime program option available. FOH Processing and Playback Equipment Pendulum OCL-2 Dual compressor/limiter DBX 1066 dual compressor/gates (4) DBX 160A compressor/limiters (2) Klark-Teknik DN3600 dual 31 band equalizer BSS DPR-901II dynamic equalizer (2) TC Electronics D-TWO Delay F/X TC Electronics M3000 Reverb F/X Lexicon PCM91 Reverb/Delay F/X Marantz 340Pro CD Player Fostex D-5, DAT Recorder Speaker clusters (per side): (SL and SR clusters are identical. There is no center cluster.) (2) Meyer 650P Powered Subwoofer (2) Meyer DS4 Mid-Bass Powered Loudspeaker (6) Meyer MSL4 2-way Powered Loudspeaker (3) Meyer UPA-2P 2-way Powered Loudspeaker (2) Meyer DF-4 Powered Loudspeaker (1) Meyer UPJ Powered Loudspeaker Groundstacks (per side): (3) Meyer CQ2 Powered Loudspeaker (2) Meyer 700 HP Powered Subwoofer Tie-ins to house equipment Power distribution is located DSL. 200A tie-in with cam-lock connectors. Edison courtesy plugs as well (6) 20A single-phase twistlock receptacles (HBL 2316) and (3) 20A , 3∅ 120/208V, twistlock receptacles (HBL 2516) are available. 56 input splitter (DSL), standard Whirlwind pin configuration, goes to: (1) transformerless main output, standard Whirlwind W-4, which is connected to the FOH Amek Recall (at media pit) via a 56 pair snake. (2) iso-transformed outputs, Whirlwind W-4 (56 pin) splitter with (1) 25’ (56 pair) fan-out (onstage). Wired microphone, stands, input boxes, and DI inventory: (2) Shure MX418SE podium/condenser microphone (6) Shure SM57-LC dynamic instrument/vocal microphone (6) Shure SM58-LC dynamic instrument/vocal microphone (1) Shure BETA 52 dynamic drum microphone (1) Audio-Technica ATM87R condenser boundary microphone 9 Technical Specifications for Incoming Shows Kodak THEATRE Rev. Date: 2/06 (2) Shure KSM32/CG condenser instrument microphone (2) Shure BETA 87A condenser vocal microphone (4) Audio-Technica AT4041 condenser instrument microphone (4) Audio-Technica ATM25 dynamic hypercartoid instrument microphone (12) tall and (6) short tripod microphone stands (12) round bases for microphone stands (2) 20 pair input boxes, 200' long (2) 20 pair input boxes, 250' long (12) Countryman DI boxes (Type 85 FET Direct Box) Wireless microphone inventory: *all wireless mics are UB, range is 692-716 MHz (8) Shure U124D wireless receivers (total of 8 handheld and lavalier mics can be used) (4) Shure BETA87 wireless handhelds (4) Shure 58 wireless handhelds (4) Shure MX184 Lavalier microphones w/ body packs Portable PA System: (1) Mackie 1642VLZPro Console (4) Meyer UPJ Powered Loudspeakers with stands (2) Meyer 650P Powered Subwoofers (4) Channels BSS Graphic Equalization (1) Denon combination CD/Cassette Recorder Headset (communication) System The house headset communications system is designed as a permanent 4-channel party line (analog) intercom system which can be interfaced with temporary wired and wireless communication systems. The headset and belt pack inventory includes: (16) Belt packs, single channel (wired) (7) Wireless receivers (single channel, cannot be on separate channels) (20) Headsets, single and double muff available (3) TW12B system interface (RTS interface) The analog dry wire system can be used to run any analog system, not only Clear-com, throughout the theater. In addition to the analog systems, the theatre also has a dry line system for digital intercom (CAT 5) using standard RJ45 connectors. Hearing Assistance Package The theater is equipped with a Sennheiser IR transmitter system for hearing assistance. In addition to the transmitter and radiators installed around the auditorium, the theater owns 146 bodyworn stethoscopic receivers and 18 induction neck loops with receivers to plug directly into hearing aids. 10 Technical Specifications for Incoming Shows Kodak THEATRE House Drapery Package Softgood Type Rev. Date: 2/06 (6) Masking Borders, small (2) Masking Borders, large (12) Masking Legs (12) Masking Tabs (4) Masking Legs (6) Masking Legs Size 12'h x 75'w 18'h x 75'w 32'h x 12'w 32'h x 17'w 32'h x 24'w 32'h x 32'w Color black black black black black black (1) Scrim, sharkstooth (1) Scrim, sharkstooth (1) Cyclorama, Leno 39'h x 63'w black 40'h x 63'w white 40'h x 66'w white Wht Full notes 26.5 oz 0% chain bottom, unlined 26.5 oz 0% chain bottom, unlined 26.5 oz 0% chain bottom, unlined 26.5 oz 0% chain bottom, unlined 26.5 oz 0% chain bottom, unlined 26.5 oz 0% chain bottom, unlined NA NA NA NA bottom pipe NA bottom pipe NA bottom pipe House Rigging Equipment The Grand Drape occupies lineset #1. In general, the linesets are spaced on 6" centers but skip some locations. In the 60' depth of fly tower, there is a total of 76 manual linesets and 4 motorized sets for the tabsets (upstage/downstage blacks). In addition to the fly house linesets and tabsets, the theatre is equipped with the standard auxiliary equipment needed to rig a show. This inventory includes batten extensions, sandbags, sidearms, light ladders, 8 boom bases, and 3 sets of unassembled traveler track sets. Note that the theatre does not supply consumables such as wire rope, tape, shackles, gel, etc., free of charge. The theatre also owns (4) 1-ton chain motors and other miscellaneous rigging equipment (such as spanning beams) which require an additional rental charge. Rear-stage Gantry System The rear-stage gantry system is a permanent chain hoist installation which allows heavy equipment and/or scenery to be moved anywhere within the Rear Stage area. It consists of four beams (approx. 7' long) which roll SL or SR and have a chain hoist at each end. There are a total of 8 one-ton hoists in the gantry system. Performance Haze, Confetti, etc. The theatre does not have any in-house fog or haze machines. Additionally, the use of such machines necessitates changes to the fire alarm system which require the presence of a fire marshal whenever the pubic is present in the theatre. The costs of said fire marshal are borne by the production. Any use of confetti, snow, water, etc. which will land in or on the audience must be approved by Theatre Management. Mylar confetti may not be used under any circumstances. Wardrobe/Hair and Makeup The Kodak THEATRE has a fully equipped wardrobe room including the following equipment: (1) Commercial washer and dryer (1) Domestic (top loading) washer and dryer (2) Industrial (Bernina) sewing machines 11 Technical Specifications for Incoming Shows Kodak THEATRE Rev. Date: 2/06 (2) Steamers, (2) ironing boards, (2) irons (6) Rolling clothes racks (2) standing full-length mirrors (6) rolling makeup stations Note that the theatre is not equipped with a full-length mirror in every dressing room and that director's chairs or stools must be provided for use with the make-up tables. The wardrobe equipment may not be used by the production without supervision from the Wardrobe House Head. Other Technical Equipment The theater is equipped with a variety of other equipment useful for touring productions. The following list includes items from Genie lifts to a stage manager's podium. Extension ladders (16', 32'), Step ladders (4' - 16') (1) 30' single person lift, battery powered, Genie AWP 30S (1) 40' single person lift, battery powered, Genie AWP 40S (1) Genie GS-1930 (scissors lift, 19' max platform height, 30" wide) (1) 5,000 lb capacity forklift, 4' and 6' forks, at dock/stage level various and sundry tech tables for the house (18) 6' & 8' folding tables with skirting (6) 5' diameter round tables some black folding chairs with padding black, stacking, padded orchestra chairs (two sets of approx. 60) limited amount of pipe and drape. (2) Speaker's podiums, mahogany wood finish (60) Manhassett music stands w/ clip lights (1) Conductor stand, Hamilton KB300A (1) Conductor podium, Manhasset P1154 (1) Upright rehearsal piano, Yamaha T116, 45", polished ebony (2) rehearsal step units, black, 3'w x 5'l x 33-7/8" tall (12" run, 6-7/8" rise) (2) rehearsal step units, black, 2'w x 5'l x 33-7/8" tall (12" run, 6-7/8" rise) (2) rehearsal step units, black, 18"w x 5'l x 33-7/8" tall (12" run, 6-7/8" rise) (1) video cameras on Mezz 1 (framed for the stage). (1) video camera in the orchestra pit (conductor camera) Riser package includes: (10) 4'x8' risers, 1' high (black), StageRight (3) 4'x8' risers, 2' high (black), StageRight (2) 24" Stair, StageRight 12 Technical Specifications for Incoming Shows Kodak THEATRE Rev. Date: 2/06 Unions The Kodak THEATRE is home to the following unions: Stagehands: IATSE Local 33 1720 W. Magnolia Blvd. Burbank, CA 91506 (818) 841-9233 Fax: (818) 567-1138 Business Agent: James Wright Wardrobe: IATSE Local 768 13245 Riverside Drive Suite 300 Sherman Oaks, 91423 (818) 789-8735 Fax: (818) 905-6297 Business Agent.: William Damron Treasurers & Ticket sellers: IATSE Local 857 13245 Riverside Drive Suite 300-C Sherman Oaks, CA 91423 (818) 990-7107 Fax: (818) 990-8287 Business Agent.: Dierdre Floyd Hair & Makeup: IATSE Local 706 828 N. Hollywood Way Burbank, 91505 (818) 295-3933 Fax: (818) 295-3930 Business Agent.: Leonard Engelman Musicians: AFM Local 47 817 N. Vine St. Hollywood, CA 90032-3779 (323) 993-3181 Fax: (323) 461-5260 President: Hal Espinosa 13 Technical Specifications for Incoming Shows Kodak THEATRE Rev. Date: 2/06 Contact Cheat Sheet: Jay Thomas, VP/General Manager Contact Jay re: booking a date(s), rental rates for the theater and/or equipment, contract and insurance issues. Administrative Assistant: Rachelle Granillo, x6380 Laura Patterson, Technical Director Contact Laura re: all stage related issues including labor, schedule, cost estimates, union contract questions, production space use, phones, special effects, pyro-technics, fire marshals, camera issues, facility maintenance, custodial, trucking, and dock usage. Assistant Technical Director: Mike Fairman x6384 Operations Manager: Russ Malcomb, x6350 Sergio Ruezga, Director Event Services Contact Sergio re: all FOH related issues including merchandise, FOH scheduling, catering, programs, Box Office issues, event security, EMS services, sign-language interpreter services, press, lobby events, and VIP/talent arrival and parking. Miranda Garza, Box Office Treasurer All ticket related issues including Ticketmaster. Assistant Box Office Treasurer: Joe Orenals x6387 Barbara Brass, Wolfgang Puck Ctrg & Evts, (323) 491-1258, barbara.brass@wolfgangpuck.com Contact Barbara regarding any front-of-house receptions, dinners, or lunches hosted within the theater. Barbara is also the contact for meals in Wolfgang Puck's Grand Ballroom or the Annex (junior ballroom). Olivia Sharratt, Wolfgang Puck Ctrg & Evts, (323) 491-1261, olivia.sharratt@wolfgangpuck.com Contact Olivia regarding any backstage catering. One week advance notice requested. Carl George, Director of Special Events, H&H, (323) 817-0201, cgeorge@cimgroup.com Contact George regarding issues within the Hollywood and Highland complex (outside of the Kodak THEATRE) including red carpets, sponsorship exhibits outside, and street closures. Marshal Moton, Transportation Manager, H&H, (323) 817-0226, mmoton@cimgroup.com Contact Marshal regarding the use of parking and dock areas such as Orange Court. Marshal can also help with truck parking and staging. Ivan Valle, Manager, 5 Star Parking, (323) 468-0720, ivalle@fivestarparking.com Contact Ivan re: parking structure issues such as pre-payment of crew parking. Chris Stampe, Director of Group Sales, Renaissance Hotel, (323) 491-1208 Contact Chris regarding hotel room bookings or hotel ballroom bookings. 14 15 16 17 Kodak Theatre 4/30/03 House Lineset Schedule PL is upstage edge of Fire Pocket LS # From PL Assignment 1 1' 2 3 4 5 6 2'-2" 2'-8" 3'-2" 3'-8" 4'-2" Border 1* Leg 1** 7 8 9 10 11 12 13 14 15 16 5'-8" 6'-2" 6'-8" 7'-2" 7'-8" 8'-2" 8'-8" 9'-2" 9'-8" 10'-2" Full stage Black Out 17 18 19 20 21 22 23 11'-8" 12'-2" 12'-8" 13'-2" 13'-8" 14'-2" 14'-8" 24 25 15'-8" 16'-2" 26 27 28 29 30 17'-8" 18'-2" 18'-8" 19'-2" 19'-8" 31 20'-8" 32 33 21'-8" 22'-2" 34 35 23'-8" 24'-2" 36 37 38 39 25'-2" 25'-8" 26'-2" 26'-8" Grand Drape Border 2 Legs 2 Border 3 Legs 3 Border 4 Legs 2 SL DS Tab set SL US Tab set * Dimensions All borders are 66' wide 18' h 12' w 3@32' 18' h 12' h 12' h 32'h x 24'w 32'h x 24'w LS # 40 41 From PL Assignment 27'-8" 28'-2" 42 43 44 29'-8" 30'-2" 30'-8" 45 46 47 48 49 32'-2" 32'-8" 33'-2" 33'-8" 34'-2" 50 51 52 35'-8" 36'-2" 36'-8" 53 37'-8" 54 55 56 39'-2" 39'-8" 40'-2" 57 58 59 60 61 41'-8" 42'-2" 42'-8" 43'-2" 43'-8" 62 63 45'-2" 45'-8" 64 65 66 67 68 69 70 71 72 73 47'-8" 48'-2" 48'-8" 49'-2" 49'-8" 50'-2" 50'-8" 51'-2" 51'-8" 52'-2" 74 53'-8" 75 76 55'-4-1/4" 55'-10-1/4" Dimensions Border 5 Legs 5 Full Stage BO SR DS Tab set SR US Tab set 32'h x 24'w 32'h x 24'w ** All legs are 32' high 18 19 20 21 22 23 24