Cold Cathode Ballast
Transcription
Cold Cathode Ballast
Generated by PDFKit.NET Evaluation Cold Cathode Ballast u u u u u u Complies with UL 935 Standard CAN be used with External Flashers and Dimmers Maximum 990 Volts to Ground Class P Thermally Protected Slotted Mounting Holes for Easy Retrofit Internal Wiring Compartments on Both Ends Eliminates External Wiring Boxes u High Power Factor Models Available www.franceformer.com 2268 Fairview Blvd Click here to unlock PDFKit.NET PO Box 300 Fairview, TN 37062 voice 800-753-2753 fax 615-799-3199 Generated by PDFKit.NET Evaluation Cold Cathode Ballast Cold Cathode Instant Start Lamp Ballasts Normal Power Factor One or Two Lamps CATALOG LAMP FOOTAGE PRIMARY NUMBER VOLTS HZ V.A. AMPS MIN MAX 2815 D 2820 D 2815 K 2820 K 8 8 8 8 16 16 16 16 120 120 277 277 60 60 60 60 3.0 3.7 1.5 1.7 360 450 415 470 SECONDARY VOLTS mA 990 990 990 990 LEAD LENGTH INCHES WEIGHT LBS. 150 200 150 200 10 10 10 10 20 21 20 21 200 200 10 10 21 21 High Power Factor Two 8 FT Lamps Only 2820 DH 2820 KH 16 16 16 16 120 277 2.1 1.0 60 240 60 249 990 990 16.724 1.250 TYP 1.753 TYP 17.600 .250 X .500 SLOT TYP 4 PLCS .438 TYP 16.724 .688 TYP 3.776 3.476 2.000 TYP .312 TYP .750 1.250 TYP TYP email: france@franceformer.com xs09029 07/02/09 Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation P 6 K A 2 N G Cold Cathode Transformer ndle a H y Carr y s a PE itch w S f f POn/O u UL 2161 Listed and NEC Compliant u Available in a variety of models Primary voltages of 120 or 277.Secondaries from 5000 to 9000 volts -120mA. u Secondary Circuit Ground Fault Protection Disables unit upon detection of arcs to ground and other conditions which may compromise transformer performance. Resists nuisance tripping. u Easy Wiring Methods Virtual Ground and Series Wiring Methods. u Self Enclosed u Auto Reset Doesnt require separate enclosure. After fault, automatically attempts to reset three (3) times within approximately ten (10) u Multiple Knockouts seconds reducing nuisance tripping. Manual Allows for a variety of mounting configurations reset possible at any time. u Easy Off Cover u Outdoor Non-weatherproof www.franceformer.com 2268 Fairview Blvd Click here to unlock PDFKit.NET PO Box 300 Fairview, TN 37062 voice 800-753-2753 fax 615-799-3199 Generated by PDFKit.NET Evaluation Cold Cathode Transformer P6KA2NG NORMAL POWER FACTOR Catalog Number 90120 P6KA2NG 75120 P6KA2NG 60120 P6KA2NG 50120 P6KA2NG 90120 P6KA2NG 75120 P6KA2NG 60120 P6KA2NG 50120 P6KA2NG VAC Hz 120 120 120 120 277 277 277 277 Secondary Volts mA 60 9000 120 60 7500 120 60 6000 120 60 5000 120 60 9000 120 60 7500 120 60 6000 120 60 5000 120 Primary Input Wt. Amp. Lbs. VA 9.0 7.5 6.0 5.0 4.0 3.3 2.6 2.3 1080 900 720 600 1080 900 720 600 45 42 30 29 45 42 30 29 Case Dimensions A H B L W 17.55 17.55 13.35 13.35 17.55 17.55 13.35 13.35 4.62 4.62 4.62 4.62 4.62 4.62 4.62 4.62 8.00 8.00 8.47 8.47 8.00 8.00 8.47 8.47 15.07 15.07 10.87 10.87 15.07 15.07 10.87 10.87 C 16.41 16.41 12.21 12.21 16.41 16.41 12.21 12.21 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 Contact FRANCE for information on Other Secondary Voltage and mA Requirements. What may cause the S.C.G.F.P. circuit in the P 6KA2NG to trip: u Reversing the hot (black) or neutral (white) input power wires. u Leaving the service ground unconnected. u Connecting or grounding the midpoint of a sign to Earth ground. u Excessive leakage currents caused from excessive moisture within or on the sign, tubing installed too close to metal, corroded insulators or standoffs, or conductive debris such as insects, dirt, etc. between live high voltage sign components and ground. u Electrical shorting or arcing from live high voltage sign components to ground. When will a S.C.G.F.P. circuit in the P 6KA2NG not trip: u Ground faults on the primary/line side of the transformer. u Series arcs in the sign system (arcs across sign tubing interconnections). u Breaks in the sign tubing, degassed tubing, or opens in the high voltage connections without a corresponding short or arc to ground. u Shorts to an ungrounded metal part within or near a sign. A W NO PCB .970 ON OFF 1.456 H 3.338 L B C .375 X .750 SLOT, 4 PLCS email: france@franceformer.com Copyright 2001 xs09014 05/18/2009 Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation Ser viceMaster - Open Core & Coil Universal Replacement Units 3020 SEG-U 6025 SEG-U u Designed for indoor use in small signs where space is at a premium u Utilizes a high quality Polyester impregnation to guard against moisture absorption u Primary leads and highly flexible GTO-10 Secondary leads are 6 long on 3020 and 14 long on 6025. u 3020 - One End Ground, self-adjusting 2000 to 3000 Volts u 6025 - Mid-Point Ground, self-adjusting 3500 to 6000 Volts www.franceformer.com 2268 Fairview Blvd Click here to unlock PDFKit.NET PO Box 300 Fairview, TN 37062 voice 800-753-2753 fax 615-799-3199 Generated by PDFKit.NET Evaluation SEG -U - Open Core & Coil Catalog Number VAC HZ Secondary Primary VA Volts mA Input Wt. Amp lbs. 6025 SEG-U 3020 SEG-U 120 120 60 60 6000 3000 1.60 0.70 25 20 190 85 7.7 3.4 Case Dimensions in Inches A W H B 3.250 3.062 5.688 2.562 6.250 3.687 2.812 3.062 3.125 2.125 L L 3020 SEG-U H A W B H L A W B 6025 SEG-U email: france@franceformer.com xs09018 06/02/09 Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation WINDOW FRAME 6000 FE1G 9000 FE1G u Self-Adjusting - 12000 FE1G u 6000V and 9000V available in Non- 6000 FE1G & 6000 FE1G-D 2000 - 6000V 9000 FE1G & 9000 FE1G-D 2000 - 9000V 12000 FE1G-D 2000 - 12000V u Secondary Circuit Ground Fault Protection Detects arcs to ground and disables unit. Power supply must be manually reset. Dimming & Dimming versions. 12000V Model Dimming Only. u UL 2161 Listed Type 7 u No Jelly-Beaning or Mercury Migration u Vacuum Encapsulated High Voltage Section Protects High Voltage circuitry and reduces heat. u Open Circuit Detection Detects opens in High Voltage circuit and disables unit. Power supply must be manually reset. u Lightweight u 10' Line Cord www.franceformer.com 2268 Fairview Blvd Click here to unlock PDFKit.NET PO Box 300 Fairview, TN 37062 voice 800-753-2753 fax 615-799-3199 Generated by PDFKit.NET Evaluation Window F rame Specifications - at 120 VAC, 60 Hz Secondary Voltage mA 6000 Series 2-6 kV* 36** 9000 Series 2-9 kV* 34** 12000 Series 2-12 kV* 40** Catalog Number Primary VA Input Amps 102 180 228 .85 1.3 1.9 Dimensions in Inches D E C A B 5.700 1.750 3.125 1.600 5.900 5.750 2.125 4.125 2.875 6.000 5.625 2.100 4.125 2.875 5.900 F 6.500 6.875 6.825 Weight in lbs. 1.6 2.2 2.9 E A C D B F *See notes regarding Dimming Models. ** Short circuit secondary current. All models actually operate tubing at a current that produces the same tubing brightness (comparable to core/coil transformers). Each power supply is complete with a 10 three-conductor line cord with 3-prong plug, a pull-chain On/Off switch, and 18 long secondary GTO leads. Frequency: 20 kHz Dimming Models: To dim models equipped with the dimming feature (-D models), use the rocker switch located on the end panel (9000 volt & 12000 volt models) or side (6000 volt models) of the power supplies. When dimmed, power supplies will provide light output comparable to a 20 mA unit. Reductions in tubing load may be required when dimming neon-filled tubing. email: france@franceformer.com xs09020 07/07/09 Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation P-ESE Ener g y Saver = Less Energy = More money in your pocket!! Uses 20-25% less energy than standard neon transformers. Same watts per foot as most LED systems on the market. Diagnostic Circuit - LED indicates the reason for service, allowing for quick, easy troubleshooting. Primary Wiring Requirements of a Non-SCGFP - with the added safety of Secondary Ground Fault Protection. Service Button - For easy troubleshooting of ground faults and primary wiring problems. Overrides the SCGFP for up to 30 minutes. Self-Adjusting - 2 Models 3000 - 15000 Auto Reset - After secondary ground fault, automatically attempts to reset three times within ten seconds. Manual reset possible at any time, by disconnecting primary power. Secondary Circuit Ground Fault Protection - (SCGFP) Disables unit upon detection of arcs to ground in compliance with UL2161 and NEC requirements. Ready to Mount. Step Plate eliminates double-nutting. Easy Wiring Methods - Virtual Ground and Series Wiring Methods User Friendly - Adapts to most grounding situations. *Can be used in flashing applications. * UL does not have listing requirements for transformers that are remotely dimmed or flashed. www.franceformer.com Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation P-ESE Ener g y Saver ENERGY SAVER ServiceMaster REPLACES Service Button LED Indicator Catalog Number VAC Hz 15000 P-ESE 9000 P-ESE 120 120 60 60 NORMAL POWER FACTOR Secondary Primary Input Wt. Amps Lbs. V.A. Volts mA L 15000 9000 20 20 170 190 1.40 1.60 27 13 9.20 8.37 W Case Dimensions A H 4.65 3.70 6.045 4.890 B C 10.13 11.25 3.00 9.00 10.00 2.00 Note: Only use with P-ESE Models. Do Not mix P5G-2E Models. 2268 Fairview Blvd PO Box 300 Fairview, TN 37062 voice 800-753-2753 fax 615-799-3199 xs09007 07/07/09 Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation P5K A2NG -2E Series NO Transformer Box Required for Interior Installations! LED Indicator ENFORMER Service Button ON/OFF Toggle Switch Diagnostic Circuit- LED indicates the reason for service, allowing for quick, easy troubleshooting. Primary Wiring Requirements of a Non-SCGFP - with the added safety of Secondary Ground Fault Protection. Service Switch - For easy troubleshooting of ground faults and primary wiring problems. Overrides the SCGFP for up to 30 minutes. Auto Reset - After secondary ground fault, automatically attempts to reset three times within ten seconds. Manual reset possible at any time by disconnecting primary power. *Can be used in flashing/dimming applications. Secondary Circuit Ground Fault Protection - (SCGFP) Disables unit upon detection of arcs to ground in compliance with UL2161 and NEC requirements. Easy Wiring Methods - Virtual Ground and Series Wiring Methods User Friendly - Adapts to most grounding situations. Easy to carry handle. On/Off Toggle Switch. *UL does not have listing requirements for transformers that are remotely dimmed or flashed. www.franceformer.com Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation P5K A2NG -2E Series NORMAL POWER FACTOR Catalog Number VAC Hz 15030 P5KA2NG-2E 12030 P5KA2NG-2E 10530 P5KA2NG-2E 9030 P5KA2NG-2E 7530 P5KA2NG-2E 6030 P5KA2NG-2E 5030 P5KA2NG-2E 4030 P5KA2NG-2E 15060 P5KA2NG-2E 12060 P5KA2NG-2E 9060 P5KA2NG-2E 7560 P5KA2NG-2E 15030 P5KA2NG-2E 12030 P5KA2NG-2E 10530 P5KA2NG-2E 9030 P5KA2NG-2E 7530 P5KA2NG-2E 6030 P5KA2NG-2E 5030 P5KA2NG-2E 4030 P5KA2NG-2E 120 120 120 120 120 120 120 120 120 120 120 120 277 277 277 277 277 277 277 277 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 Secondary Volts mA 15000 12000 10530 9000 7500 6000 5000 4000 15000 12000 9000 7500 15000 12000 10530 9000 7500 6000 5000 4000 30 30 30 30 30 30 30 30 60 60 60 60 30 30 30 30 30 30 30 30 Primary V.A. 435 380 310 285 250 200 170 140 900 720 565 460 425 385 310 275 235 190 160 130 Input Wt. Amp. Lbs. 3.60 3.15 2.55 2.35 2.10 1.65 1.40 1.15 7.50 6.00 4.70 3.85 1.55 1.40 1.15 1.00 .85 .70 .60 .50 25 23 23 19 17 16 16 15 30 29 27 25 25 23 23 19 17 16 16 15 Case Dimensions A H B L W 13.35 13.35 13.35 13.35 13.35 13.35 13.35 13.35 14.85 14.85 13.35 13.35 13.35 13.35 13.35 13.35 13.35 13.35 13.35 13.35 4.50 4.50 4.50 4.50 4.00 4.00 4.00 4.00 5.50 5.50 4.50 4.50 4.50 4.50 4.50 4.50 4.00 4.00 4.00 4.00 7.42 7.42 7.42 7.42 6.13 6.13 6.13 6.13 8.47 8.47 7.42 7.42 7.42 7.42 7.42 7.42 6.13 6.13 6.13 6.13 C 12.21 12.21 12.21 12.21 12.21 12.21 12.21 12.21 13.71 13.71 12.21 12.21 12.21 12.21 12.21 12.21 12.21 12.21 12.21 12.21 10.87 10.87 10.87 10.87 10.87 10.87 10.87 10.87 12.37 12.37 10.87 10.87 10.87 10.87 10.87 10.87 10.87 10.87 10.87 10.87 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 A W NO PCB LED" INDICATOR .940 ON OFF Toggle Switch 20 amp 120V Service Switch 1.49 H 3.35 Service Switch does not operate without proper grounding. L B (MTG) DIAGNOSTIC LED OPERATION Indicates LED Fault Code Steady ON Continuous Flashing 1 - Flash 2 - Flash 3 - Flash 4 - Flash 5 - Flash Operating normally In Service Mode 15 second Diagnostic & Auto Reset Mode Secondary Ground Fault with service ground connected Secondary Ground Fault when service ground not connected Input Voltage exceeds 120% of rated Line & Neutral reversed on input connections C .375 X .750 SLOT, 4 PLCS 2268 Fairview Blvd w PO Box 300 w Fairview, TN 37062 w voice 800-753-2753 w fax 615-799-3199 xs09005 04/29/09 Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation High Output 800mA Rapid S t art Lamp Ballast s Available in 120V DR & 277V KR u Thermally Protected u Extra Long Lead Wires u Slotted Mounting Holes Allow for Easy Retro-Fit www.franceformer.com 2268 Fairview Blvd Click here to unlock PDFKit.NET PO Box 300 Fairview, TN 37062 voice 800-753-2753 fax 615-799-3199 Generated by PDFKit.NET Evaluation High Output 800mA Rapid S t art Lamp Ballast s DR Models 120 VAC / 60 Hz Catalog Model No. (1) Min. Starting temperature - 20° F High Power Factor KR Models 277 VAC / 60 Hz Lamp Max. Open Footage Line Circuit Min. Max. Amp. Voltage** Length2 Net. In Inches Wt. Case Mount Lbs. Catalog Model No. Lamp Max. Open Net. Length2 In Inches Footage Line Circuit Wt. Min. Max. Amp. Voltage** Case Mount Lbs. ONE Lamp 168 DR 268 DR 2 4 6 8 0.66 1.20 390 500 10.50 10.50 11.3 11.3 10 11 ONE Lamp 268 KR 288 KR 4 4 8 8 0.55 0.77 500 550 10.50 10.50 11.3 11.3 11 11 TWO Lamps 268 DR 288 DR 2128 DR 388 DR 448DR 458DR 468DR 4 8 16 16 6 8 16 12 16 24 24 16 20 24 1.20 1.80 2.20 2.70 2.00 2.30 2.80 500 530 720 720 550 590 720 10.50 10.50 10.50 10.50 10.50 10.50 10.50 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11 11 12 12 11 12 12 TWO Lamps 268 KR 288 KR 2128 KR 388 KR 448 KR 458 KR 468 KR 4 8 16 16 6 8 16 12 16 24 24 16 18 24 0.55 0.77 0.9 1.1 0.8 0.95 1.1 500 550 720 720 550 590 720 10.50 10.50 10.50 10.50 10.50 10.50 10.50 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11 11 12 12 11 12 12 12 18 24 36 16 20 24 32 40* 1.40 2.00 2.70 3.60 2.00 2.30 2.80 3.20 4.00 500 590 720 1000 550 590 720 940 720 10.50 10.50 10.50 15.25 10.50 10.50 10.50 15.25 15.25 11.3 11.3 11.3 16.05 11.3 11.3 11.3 16.05 16.05 11 10 12 23 11 12 12 18 19 THREE Lamps 368 KR 8 18 388 KR 16 24 448 KR 6 16 458 KR 8 18 468 KR 16 24 488 KR 20 32 588 KR 16 40 0.86 1.1 0.8 0.95 1.1 1.4 1.7 590 720 550 590 720 940 720 10.50 10.50 10.50 10.50 10.50 15.25 15.25 11.3 11.3 11.3 11.3 11.3 16.05 16.05 10 12 11 12 12 18 19 FOUR Lamps 448 KR 6 458 KR 8 468 KR 16 488 KR 20 4128 KR 36* 568 KR 20 588 KR 16* 668 KR 24 688 KR 36* 16 18 24 32 48* 30 40* 36 48* 0.8 0.95 1.1 1.4 1.7 1.5 1.7 1.7 1.75 550 590 720 940 720 900 720 1000 720 10.50 10.50 10.50 15.25 15.25 15.25 15.25 15.25 15.25 11.3 11.3 11.3 16.05 16.05 16.05 16.05 16.05 16.05 11 12 12 18 25 17 19 18 20 FIVE Lamps 568 KR 588 KR 668 KR 688 KR 20 30 16* 40* 24 36 36* 48* 1.5 1.7 1.7 1.75 900 720 1000 720 15.25 15.25 15.25 15.25 16.05 16.05 16.05 16.05 17 19 18 20 SIX Lamps 668 KR 688 KR 24 36 36* 48* 1.7 1.75 1000 720 15.25 15.25 16.05 16.05 18 20 THREE Lamps 348 DR 6 368 DR 12 388 DR 16 3128 DR 26 448 DR 6 458 DR 8 468 DR 16 488 DR 20 588 DR 16* FOUR Lamps 448 DR 6 458 DR 8 468 DR 16 488 DR 20 4128 DR 36* 568 DR 20 588 DR 16* 668 DR 24 688 DR 36* FIVE Lamps 568 DR 588 DR 668 DR 688 DR 16 20 24 32 48* 30 40* 36 48* 20 30 16* 40* 24 36 36* 48* 2.00 2.30 2.80 3.20 3.90 3.20 4.00 4.05 5.00 3.20 4.00 4.05 5.00 550 590 720 940 720 900 720 1000 720 900 720 1000 720 10.50 10.50 10.50 15.25 15.25 15.25 15.25 15.25 15.25 15.25 15.25 15.25 15.25 11.3 11.3 11.3 16.05 16.05 16.05 16.05 16.05 16.05 16.05 16.05 16.05 16.05 11 12 12 18 25 17 19 18 20 17 19 18 20 SIX Lamps 668 DR 24 36 4.05 1000 15.25 16.05 18 688 DR 36* 48* 5.00 720 15.25 16.05 20 * For ballasts having multi-lamp capacity, consult wiring diagram for proper installation. ** All ballasts have a maximum 600 V to ground. NOTES: (1) Ballasts are not recommeded for use with external flashers or dimmers. (2) Cross-sectional dimensions are 3.174 wide and 2.79 high. Mouting holes are 2 apart. The SIGN MANS SIX are printed in RED. email: france@franceformer.com xs09026 06/25/09 Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation Space Savings Reliable Performance The P5G-2ELP Low Profile Neon Power Supply saves space and improves installation flexibility. Space Saving Shallow raceways are no longer a challenge with this innovative design. At only 3.4 inches in height, this new power supply will fit easily into tight spaces. Flexible Configuration Available in a 120v and a 277v primary version, and in a 9030 and 7530 configuration, the P5G-2ELP will meet many different sign configurations. Reliable Design UL2161 secondary ground fault protection, pre-wired primary leads, and last-fault diagnostics are standard in this power supply backed by France reliability. Click here to unlock PDFKit.NET Made in the USA Generated by PDFKit.NET Evaluation P5G-2ELP Electrical and Mechanical Data Catalog Number 9030 7530 9030 7530 P5G-2ELP P5G-2ELP P5G-2ELP P5G-2ELP 277 277 VAC Hz Secondary Primary Input Wt. VA Amps Lbs. Volts mA 120 120 277 277 60 60 60 60 9000 7500 9000 7500 30 30 30 30 285 250 280 235 2.35 2.10 1.00 0.85 15.5 15.5 15.5 15.5 Case Dimensions L W H A B C D E F 10.00 10.00 10.00 10.00 3.69 3.69 3.69 3.69 3.40 3.40 3.40 3.40 8.37 8.37 8.37 8.37 2.05 2.05 2.05 2.05 9.00 9.00 9.00 9.00 1.31 1.31 1.31 1.31 2.18 2.18 2.18 2.18 1.88 1.88 1.88 1.88 DIAGNOSTIC LED FAULT CODES LED Fault Code Indicates Steady ON Continuous Flashing 1 - Flash 2 - Flash 3 - Flash 4 - Flash 5 - Flash Operating normally In Service Mode 15 second Diagnostic & Auto Reset Mode Secondary Ground Fault with service ground connected Secondary Ground Fault when service ground not connected Input V olt age exceeds 120% of rated Line & Neutral reversed on input connections Click here to unlock PDFKit.NET xs09004 02/18/09 Generated by PDFKit.NET Evaluation Channel Letter 7500 OE1G 5000 OE1G 10000 OE1G Fits Inside Channel Letters Under 1 3/4 High Tubing. w UL2161 Listed Type 3 Neon Power Supply (Outdoor Non-Weatherproof) 2005 NEC Compliant Circuit Ground Fault w Secondary Protection with Auto-Restart = = = w Open Circuit Protection = = w Detects arcs to ground and disables unit. Unit will attempt 2 restarts before tripping off. Power Supply can be manually reset if unit trips off. Detects open circuits in high voltage circuit and disables unit. Power Supply can be manually reset if unit trips off. Operating Range -30 degrees F to 122 degrees F w Self Adjusting for Line & Load from 1 to 5, 7.5 & 10 kV. w w w 30mA Self Adjusting Output w No Jelly-Beaning w Grounded Mounting Foot w Built-in GTO Fittings for Sleeving w 1/2 Conduit Fitting for Primary Wiring High Power Factor No Mercury Migration www.franceformer.com 2268 Fairview Blvd. Click here to unlock PDFKit.NET P.O. Box 300 Fairview, TN 37062 voice 1- 800-753-2753 fax 615-799-3199 Generated by PDFKit.NET Evaluation Channel Letter CATALOG NUMBER EQUIVALENT SECONDARY PRIMARY VOLTAGE FREQUENCY CURRENT VOLTAGE CURRENT 5000 OE1G 7500 OE1G 120 V 10000 OE1G 120 120 VV 50/60 HZ 50/60 HZ 50/60 HZ (+-10%) 120 V (+-10%) (+(-+-10%) 10%) B NEON MERCURY 0.5 A 5000V 30mA 14 FT 16 FT 0.75 A 7500V 30mA 21 FT 25 FT 1.0 A 10,000V 30mA 29 FT 34 FT A E 32 OUTPUT LEADS 1WF8 12mm TUBE LOADING D 42 INPUT LEADS NEON TUBING F 1 3/4 C TUBE SUPPORT CATALOG NUMBER 5000 OE1G 7500 OE1G 10000 OE1G DIMENSIONS IN INCHES A B C D E F 6.88 1.95 1.45 1.38 6.65 6.65 3.13 3.54 1.55 1.55 2.25 2.25 6.50 6.13 6.13 6.00 5.65 5.65 WEIGHT LBS 1.4 2.1 2.5 email: france@franceformer.com xs09015 6/02/09 Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation P5G -2E P5CG -2E Series P5CG-2E High Power Factor P5G-2E Normal Power Factor LED Indicator u Primary Wiring Requirements of a u User Friendly - Adapts to any grounding situation. Standard Transformer - with the added safety of Secondary Ground Fault Protection. u Bypass Feature - For easy troubleshooting of ground faults and primary wiring problems. Overrides the SCGFP for up to 30 minutes. u Diagnostic Circuits - LED indicates u Secondary Circuit Ground Fault Protection - (SCGFP) Disables unit upon detection of arcs to ground in compliance with UL2161 and NEC requirements. u *Can be used in flashing/dimming applications. the reason for service, allowing for quick, easy troubleshooting. www.franceformer.com 2268 Fairview Blvd Click here to unlock PDFKit.NET PO Box 300 Fairview, TN 37062 voice 800-753-2753 fax 615-799-3199 Generated by PDFKit.NET Evaluation NORMAL POWER FACTOR Catalog Number VAC Hz 15030 P5G-2E 12030 P5G-2E 10530 P5G-2E 9030 P5G-2E 7530 P5G-2E 6030 P5G-2E 5030 P5G-2E 4030 P5G-2E 15060 P5G-2E 12060 P5G-2E 9060 P5G-2E 7560 P5G-2E 6060 P5G-2E 5060 P5G-2E 4060 P5G-2E 15030 P5G-2E 12030 P5G-2E 10530 P5G-2E 9030 P5G-2E 7530 P5G-2E 6030 P5G-2E 5030 P5G-2E 4030 P5G-2E 15060 P5G-2E 12060 P5G-2E 9060 P5G-2E 7560 P5G-2E 6060 P5G-2E 5060 P5G-2E 4060 P5G-2E 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 277 277 277 277 277 277 277 277 277 277 277 277 277 277 277 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 Catalog Number VAC Hz 120 120 120 120 120 60 60 60 60 60 Secondary Primary Input Wt. Amps Lbs. VA Volts mA 3.60 21 435 15000 30 3.15 18 12000 30 380 18 310 10500 30 2.55 13 2.35 9000 30 285 2.10 7500 30 250 12 200 1.65 6000 30 12 5000 30 1.40 170 12 4000 30 140 11 1.15 7.50 39 900 15000 60 6.00 37 720 12000 60 9000 60 24 565 4.70 3.85 7500 60 21 460 19 6000 60 3.10 370 5000 60 18 2.60 310 2.20 13 4000 60 265 15000 30 21 425 1.55 19 1.40 385 12000 30 310 19 10500 30 1.15 13 275 9000 30 1.00 12 7500 30 235 .85 190 12 6000 30 .70 .60 12 5000 30 160 11 130 .50 4000 30 940 3.40 15000 60 39 750 2.70 12000 60 37 9000 60 560 2.05 24 21 1.65 7500 60 460 1.41 6000 60 385 20 5000 60 330 1.20 19 4000 60 0.87 13 240 HIGH POWER FACTOR Secondary Primary Input Wt. Amps Lbs. VA Volts mA 26 240 2.00 15000 30 1.60 25 12000 30 190 21 1.40 10500 30 170 19 145 9000 30 1.20 1.00 19 7500 30 120 120 120 120 120 120 120 120 60 60 60 60 60 60 60 15000 12000 9000 7500 6000 5000 4000 15030 P5CG-2E 12030 P5CG-2E 10530 P5CG-2E 9030 P5CG-2E 7530 P5CG-2E 15060 P5CG-2E 12060 P5CG-2E 9060 P5CG-2E 7560 P5CG-2E 6060 P5CG-2E 5060 P5CG-2E 4060 P5CG-2E 60 60 60 60 60 60 60 495 400 300 240 190 170 145 4.15 3.35 2.50 2.00 1.60 1.40 1.20 39 37 26 26 26 21 21 Case Dimensions L W H 11.25 11.25 11.25 10.00 10.00 10.00 10.00 10.00 13.00 13.00 11.25 11.25 11.25 11.25 10.00 11.25 11.25 11.25 10.00 10.00 10.00 10.00 10.00 13.00 13.00 11.25 11.25 11.25 11.25 10.00 4.656 4.656 4.656 3.700 3.700 3.700 3.700 3.700 5.375 5.375 4.656 4.656 4.656 4.656 3.700 4.656 4.656 4.656 3.700 3.700 3.700 3.700 3.700 5.375 5.375 4.656 4.656 4.656 4.656 3.700 5.205 5.205 5.205 4.890 4.890 4.890 4.890 4.890 6.200 6.200 5.205 5.205 5.205 5.205 4.890 5.205 5.205 5.205 4.890 4.890 4.890 4.890 4.890 6.200 6.200 5.205 5.205 5.205 5.205 4.890 A 9.203 9.203 9.203 8.375 8.375 8.375 8.375 8.375 10.875 10.875 9.203 9.203 9.203 9.203 8.375 9.203 9.203 9.203 8.375 8.375 8.375 8.375 8.375 10.875 10.875 9.203 9.203 9.203 9.203 8.375 B 10.125 10.125 10.125 9.000 9.000 9.000 9.000 9.000 11.875 11.875 10.125 10.125 10.125 10.125 9.000 10.125 10.125 10.125 9.000 9.000 9.000 9.000 9.000 11.875 11.875 10.125 10.125 10.125 10.125 9.000 C 3.0 3.0 3.0 2.0 2.0 2.0 2.0 2.0 3.0 3.0 3.0 3.0 3.0 3.0 2.0 3.0 3.0 3.0 2.0 2.0 2.0 2.0 2.0 3.0 3.0 3.0 3.0 3.0 3.0 2.0 Case Dimensions L W H A B C 11.25 11.25 11.25 11.25 11.25 4.656 4.656 4.150 4.150 4.150 6.062 6.062 5.580 5.580 5.580 9.203 9.203 9.203 9.203 9.203 10.125 10.125 10.125 10.125 10.125 3.0 3.0 3.0 3.0 3.0 13.00 13.00 11.25 11.25 11.25 11.25 11.25 5.375 5.375 4.656 4.656 4.656 4.150 4.150 6.200 10.875 6.200 10.875 6.062 9.203 6.062 9.203 6.062 9.203 5.580 9.203 5.580 9.203 11.875 11.875 10.125 10.125 10.125 10.125 10.125 3.0 3.0 3.0 3.0 3.0 3.0 3.0 A H LED Indicator L B W C The 9030 P5G-2E & 7530 P5G-2E has horizontal mounting of primary bushing as shown in diagram above. .375 X .750 SLOTS, 4 PLCS This end view of primary bushing is applicable to all units except the 9030 P5G-2E & 7530 P5G-2E. * UL does not have listing requirements for transformers that are remotely dimmed or flashed. * High Power Factor Models may not be dimmed. xs09006 04/29/09 Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation P5G-2UE ServiceMaster Universal Replacement Service Units Ever wish you had 8 arms? With the ServiceMaster you only need 2! True 30mA & 60mA Output - The ServiceMaster can replace 8 ratings. Ready to Mount. Step Plate eliminates double-nutting. Auto Reset - After secondary ground fault, automatically attempts to reset three times within ten seconds. Manual reset possible at any time, by disconnecting primary power. Diagnostic Circuit - LED indicates the reason for service, allowing for quick, easy troubleshooting. Secondary Circuit Ground Fault Protection - (SCGFP) Disables unit upon detection of arcs to ground in compliance with UL2161 and NEC requirements. Primary Wiring Requirements of a Non-SCGFP - with the added safety of Secondary Ground Fault Protection. Easy Wiring Methods - Virtual Ground and Series Wiring Methods Service Button - For easy troubleshooting of ground faults and primary wiring problems. Overrides the SCGFP for up to 30 minutes. User Friendly - Adapts to most grounding situations. *Can be used in flashing/dimming applications. * UL does not have listing requirements for transformers that are remotely dimmed or flashed. www.franceformer.com Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation SERVICE MASTER REPLACES 15030 & 15060 P5G-2UE 9030 & 9060 P5G-2UE 15000, 12000 & 10500 Volt 9000, 7500, 6000, 5000, 4000, 3000 & 2000 Volt Service Button LED Indicator L H .500 B The 9030 P5G-2U has horizontal mounting of primary bushing as shown in diagram above. A This end view of primary bushing is applicable to the 9060,15030 & 15060 P5G-2U only. .375 X .750 SLOTS, 4 PLCS W C Catalog Number VAC Hz 15030 P5G-2UE 9030 P5G-2UE 15030 P5G-2UE 9030 P5G-2UE 15060 P5G-2UE 9060 P5G-2UE 15060 P5G-2UE 9060 P5G-2UE 120 120 277 277 120 120 277 277 60 60 60 60 60 60 60 60 2268 Fairview Blvd NORMAL POWER FACTOR Secondary Primary Input Wt. Amps Lbs. V.A. Volts mA L 15000 9000 15000 9000 15000 9000 15000 9000 PO Box 300 30 30 30 30 60 60 60 60 510 330 530 320 940 600 980 610 4.25 2.75 1.90 1.15 7.80 5.00 3.60 2.20 21 13 21 13 39 23 39 23 Fairview, TN 37062 9.20 8.37 9.20 8.37 10.87 9.20 10.87 9.20 W Case Dimensions A H 4.65 3.70 4.65 3.70 5.37 4.65 5.37 4.65 5.71 5.39 5.71 5.39 6.20 5.71 6.20 5.71 voice 800-753-2753 10.13 9.00 10.13 9.00 11.88 10.13 11.88 10.13 B C 11.25 10.00 11.25 10.00 13.00 11.25 13.00 11.25 3.00 2.00 3.00 2.00 3.00 3.00 3.00 3.00 fax 615-799-3199 xs09003 04/29/09 Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation P8G-2B Series Neon Transformers P8G-2B Features >Easy access terminals >Service switch >Top visible diagnostic LED >Pre-wired primary leads >Carry handle >UL compliant stepped base plate Ease of Installation - Patented angled bushings for greater visibility and ease of access to electrical connections, LED, and service button. Does not block mounting screws and the step plate eliminates double-nutting. Visible advanced diagnostic LED - Faster, easier troubleshooting is provided by an intelligent circuit that detects both primary and secondary faults and communicates the cause of the fault using the on -board LED. Built-in carrying handle Primary wiring requirements of a non-SGFI transformer - With the added safety of a Secondary Ground Fault Protection with simple wire nut connections. User friendly - Adapts to most grounding situations. Easy wiring methods - Virtual midpoint and series wiring methods. Secondary Circuit Ground Fault Protection (SGFP) Disables unit upon detection of arcs to ground in compliance with UL2161, C22.2 No. 255, and NEC requirements. Auto reset - After secondary ground fault, automatically attempts to reset three times within ten seconds. Manual reset possible any any time by disconnecting and reconnecting primary power. Last Fault Recall - Allows service technician to retrieve the last fault experienced, even after the fault condition has been cleard. Bypass feature - For easy troubleshooting of ground faults, overrides the SGFP feature for up to 30 minutes. Can be used in flashing/dimming applications* *UL does not have listing requirements for transformers remotely dimmed or flashed Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation Electrical and Mechanical Data Cat alog Number 15030 P8G-2E 12030 P8G-2E 10530 P8G-2E 9030 P8G-2E 7530 P8G-2E 6030 P8G-2E 5030 P8G-2E 4030 P8G-2E 9060 P8G-2E 7560 P8G-2E 6060 P8G-2E 5060 P8G-2E 4060 P8G-2E 15030 P8G-2E 12030 P8G-2E 10530 P8G-2E 9030 P8G-2E 7530 P8G-2E 6030 P8G-2E 5030 P8G-2E 4030 P8G-2E 9060 P8G-2E 7560 P8G-2E 6060 P8G-2E 5060 P8G-2E 4060 P8G-2E VAC 120 120 120 120 120 120 120 120 120 120 120 120 120 277 277 277 277 277 277 277 277 277 277 277 277 277 Hz 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 Secondary Volts mA 15000 12000 10500 9000 7500 6000 5000 4000 9000 7500 6000 5000 4000 15000 12000 10500 9000 7500 6000 5000 4000 9000 7500 6000 5000 4000 LED Fault Code S teady ON Continuous Flashing 1 - Flash 2 - Flash 3 - Flash 4 - Flash 5 - Flash 30 30 30 30 30 30 30 30 60 60 60 60 60 30 30 30 30 30 30 30 30 60 60 60 60 60 Primary Input Wt. Amp s Lbs. VA 435 3.60 21 380 3.15 18 310 2.55 18 285 2.35 13 250 2.10 12 200 1.65 12 170 1.40 12 140 1.15 11 24 4.70 565 21 3.85 460 19 3.10 370 2.60 18 310 265 2.20 13 425 1.55 21 385 1.40 19 310 1.15 19 275 1.00 13 235 .85 12 190 .70 12 160 .60 12 130 .50 11 560 2.05 24 460 1.65 21 385 1.41 20 330 1.20 19 HIGH 240 PO WER 0.87 F A CT 13 OR Case Dimensions L W H A 12.13 12.13 12.13 9.22 9.22 9.22 9.22 9.22 12.13 12.13 12.13 12.13 9.22 12.13 12.13 12.13 9.22 9.22 9.22 9.22 9.22 12.13 12.13 12.13 12.13 9.22 4.79 4.79 4.79 3.89 3.89 3.89 3.89 3.89 4.79 4.79 4.79 4.79 3.89 4.79 4.79 4.79 3.89 3.89 3.89 3.89 3.89 4.79 4.79 4.79 4.79 3.89 5.72 5.72 5.72 5.25 5.25 5.25 5.25 5.25 5.72 5.72 5.72 5.72 5.25 5.72 5.72 5.72 5.25 5.25 5.25 5.25 5.25 5.72 5.72 5.72 5.72 5.25 12.23 12.23 12.23 9.87 9.87 9.87 9.87 9.87 12.23 12.23 12.23 12.23 9.87 12.23 12.23 12.23 9.87 9.87 9.87 9.87 9.87 12.23 12.23 12.23 12.23 9.87 B 13.36 13.36 13.36 10.87 10.87 10.87 10.87 10.87 13.36 13.36 13.36 13.36 10.87 13.36 13.36 13.36 10.87 10.87 10.87 10.87 10.87 13.36 13.36 13.36 13.36 10.87 C D 3.0 3.0 3.0 2.0 2.0 2.0 2.0 2.0 3.0 3.0 3.0 3.0 2.0 3.0 3.0 3.0 2.0 2.0 2.0 2.0 2.0 3.0 3.0 3.0 3.0 2.0 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 DIAGNOSTIC LED FAULT CODES Indicates Operating normally In Service Mode 15 second Diagnostic & Auto Reset Mode Secondary Ground Fault with service ground connected Secondary Ground Fault when service ground not connected Input V oltage exceeds 120% of rated Line & Neutral reversed on input connections xs09001 12/22/2008 Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation PBKMA G -51 Indoor/Outdoor Non-weatherproof Internal Mount Electrode Housing Junction Box u UL 2161 Recognized Component u Primary Junction Box, Allows for Quick and Easy Wiring Without the Expense of Conduit Fittings and External Junction Box u Convenient Knock Outs Will Compliment Virtually Any Spacing Requirement u Available in 120 Volt - 30 & 60 mA u Heavy Duty Steel Construction www.franceformer.com 2268 Fairview Blvd Click here to unlock PDFKit.NET PO Box 300 Fairview, TN 37062 voice 800-753-2753 fax 615-799-3199 Generated by PDFKit.NET Evaluation PBKMA G -51 NORMAL POWER FACTOR Catalog Number VAC Hz 120/277 50/60 Secondary Volts mA Primary VA Input Wt Amp. lbs L Case Dimensions W H A B * 9030 PBKMAG-51 120 60 9000 30 281 2.34 12 12.28 3.77 3.1 10.78 11.4 v 7530 PBKMAG-51 120 60 7500 30 226 1.88 12 12.28 3.77 3.1 10.78 11.4 v 6030 PBKMAG-51 120 60 6000 30 180 1.5 11 12.28 3.77 3.1 10.78 11.4 v 5030 PBKMAG-51 120 60 5000 30 161 1.34 10 12.28 3.77 3.1 10.78 11.4 v 4030 PBKMAG-51 l 3030 PBKMAG-51 120 120 60 60 4000 3000 30 30 140 101 1.17 0.85 9 9 10.65 10.65 3.77 3.77 3.1 3.1 9.15 9.15 9.78 9.78 9060 PBKMAG-51 120 60 9000 60 540 4.5 22 17.28 3.77 3.48 15.78 16.4 7560 PBKMAG-51 120 60 7500 60 450 3.75 20 17.28 3.77 3.48 15.78 16.4 6060 PBKMAG-51 120 60 6000 60 360 3 16 14 3.77 3.1 12.53 13.15 5060 PBKMAG-51 120 60 5000 60 300 2.5 14 14 3.77 3.1 12.53 13.15 * * * * * Secondary - Balanced Mid-point Ground v Secondary - Unbalanced Mid-point Ground l Secondary - One End Ground email: france@franceformer.com xs09024 06/02/09 Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation PBKMG -34 Outdoor Non-weatherproof Internal Mount Electrode Housing u UL 2161 Recognized Component u Pre-Wired Primary u No Need for 90o Bends into the Transformer u Excellent for Self-Contained Letters; Hinged Mounting Simplifies Installation and Service and Angled Case Corners Allows Minimum Tube Heights u Available in 30 & 60 mA u Heavy Duty Steel Construction www.franceformer.com 2268 Fairview Blvd Click here to unlock PDFKit.NET PO Box 300 Fairview, TN 37062 voice 800-753-2753 fax 615-799-3199 Generated by PDFKit.NET Evaluation PBKMG -34 NORMAL POWER FACTOR Catalog Number * 9030 PBKMG-34 PBKMG-34 PBKMG-34 v 5030 PBKMG-34 v 4030 PBKMG-34 * 9060 PBKMG-34 * 7560 PBKMG-34 * 6060 PBKMG-34 * 5060 PBKMG-34 v 4060 PBKMG-34 v 7530 v 6030 Secondary Primary Input Wt Volts mA VA Amp lbs 9000 7500 6000 5000 4000 9000 7500 6000 5000 4000 270 225 180 160 140 540 450 360 300 240 30 30 30 30 30 60 60 60 60 60 2.34 1.88 1.50 1.34 1.17 4.50 3.75 3.00 2.50 2.00 13 13 12 12 12 25 20 17 16 12 L 12.75 12.75 12.75 12.75 12.75 15.375 17.375 14.125 14.125 12.75 Dimensions in Inches W H A B 3.625 3.625 3.625 3.625 3.625 4.375 3.625 3.625 3.625 3.625 3.25 3.25 3.25 3.25 3.25 3.91 3.25 3.25 3.25 3.25 11.125 11.125 11.125 11.125 11.125 13.375 15.750 12.625 12.625 11.125 12.188 12.188 12.188 12.188 12.188 14.688 16.812 13.562 13.562 12.188 C 1.188 1.188 1.188 1.188 1.188 1.250 1.188 1.188 1.188 1.188 D 2.062 2.062 2.062 2.062 2.062 2.688 2.062 2.062 2.062 2.062 * Secondary - Balanced Mid-point Ground v Secondary - Unbalanced Mid-point Ground D email: france@franceformer.com xs09022 06/02/09 Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation PBKMG Outdoor Non-weatherproof Back Mount Electrode Housing 4030 PBKMG & 5030 PBKMG u UL 2161 Recognized Component u Pre-wired Primary u Back Mount Footprint Solves Problems Unique to Your Needs u Heavy Duty Steel Construction u Available in 30 and 60 mA and 120 and 277 V www.franceformer.com 2268 Fairview Blvd Click here to unlock PDFKit.NET PO Box 300 Fairview, TN 37062 voice 800-753-2753 fax 615-799-3199 Generated by PDFKit.NET Evaluation PBKMG Catalog Number VAC Hz Outdoor Non-weatherproof Back Mount Electrode Housing Secondary Primary Input Wt 120/277 50/60 Volts mA VA Amp. lbs Case Dimensions L W H A B C D E F G 5.0625 * * * 15030 PBKMG 120 60 15000 30 450 3.75 23 12.25 6.5625 4.5 10.56 4.5 5.687 4.125 2.5 6 12030 PBKMG 120 60 12000 30 379 3.00 22 12.25 6.56 4.5 10.56 4.5 5.687 4.125 2.5 6 5.0625 9030 PBKMG 120 60 9000 30 281 2.34 22 12.25 6.56 4.5 10.56 4.5 5.687 4.125 2.5 6 5.0625 v 7530 PBKMG 120 60 7500 30 226 1.88 15 11.125 4.87 3.75 9.8125 4.5 5.687 4.125 2.4375 6 3.5625 v 6030 PBKMG 120 60 6000 30 180 1.5 14 11.125 4.87 3.75 9.8125 4.5 5.687 4.125 2.4375 6 3.5625 v 5030 PBKMG 120 60 5000 30 161 1.34 13 12 4.375 4.06 10.75 3.75 5.687 4.425 1.75 6 3.125 v 4030 PBKMG 120 60 4000 30 140 1.17 12 12 4.375 4.06 10.75 3.75 5.687 4.425 1.75 6 0 3.125 * * * * * * 15060 PBKMG 120 60 15000 60 890 7.42 42 14.25 7.87 5.298 12.56 5.5 7.125 5.125 2.5 6.687 6.125 12060 PBKMG 120 60 12000 60 720 6 40 14.25 7.87 5.298 12.56 5.5 7.125 5.125 2.5 6.687 6.125 9060 PBKMG 120 60 9000 60 540 4.5 29 12.25 6.56 4.5 10.56 4.5 5.687 4.125 2.5 6 5.0625 7560 PBKMG 120 60 7500 60 450 3.75 23 12.25 6.56 4.5 10.56 4.5 5.687 4.125 2.5 6 5.0625 6060 PBKMG 120 60 6000 60 360 3 23 12.25 6.56 4.5 10.56 4.5 5.687 4.125 2.5 6 5.0625 5060 PBKMG 120 60 5000 60 300 2.5 20 12.25 6.56 4.5 10.56 4.5 v 4060 PBKMG 120 60 4000 60 240 2 16 11.125 4.875 3.75 * * * 15030 PBKMG 277 60 15000 30 450 1.63 26 12.25 6.5625 12030 PBKMG 277 60 12000 30 379 1.30 25 12.25 6.56 9030 PBKMG 277 60 9000 30 281 1.01 25 12.25 6.56 * * * 15060 PBKMG 277 60 15000 60 890 3.22 45 14.25 12060 PBKMG 277 60 12000 60 720 2.60 43 14.25 9060 PBKMG 277 60 9000 60 540 1.95 32 12.25 6.56 * Secondary - Balanced Mid-point Ground v Secondary - Unbalanced Mid-point Ground 5.687 6 3.9375 6 5.0625 9.812 4.25 5.24 3.812 1.75 4.125 3.562 4.5 10.56 4.5 5.687 4.125 2.5 6 5.0625 4.5 10.56 4.5 5.687 4.125 2.5 6 5.0625 4.5 10.56 4.5 5.687 4.125 2.5 6 5.0625 7.87 5.298 12.56 5.5 7.125 5.125 2.5 6.687 6.125 7.87 5.298 12.56 5.5 7.125 5.125 2.5 6.687 6.125 4.5 5.687 4.125 2.5 6 5.0625 4.5 10.56 ALL DIMENSIONS IN INCHES. This drawing applies only to the 4030 and 5030 PBKMG. email: france@franceformer.com xs09021 06/02/09 Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation PBKMG -51 PBKMCG -51 Indoor/Outdoor Non-weatherproof Internal Mount Electrode Housing u UL 2161 Recognized Component u Pre-Wired Primary u Available in 30 and 60 mA, 120 and 277 V, Normal and High Power Factor (12000 and 15000 available only in 30 mA) u Heavy Duty Steel Construction www.franceformer.com 2268 Fairview Blvd Click here to unlock PDFKit.NET PO Box 300 Fairview, TN 37062 voice 800-753-2753 fax 615-799-3199 Generated by PDFKit.NET Evaluation NORMAL POWER FACTOR Catalog Number VAC 15030 PBKMG-51 12030 PBKMG-51 9030 PBKMG-51 7530 PBKMG-51 6030 PBKMG-51 5030 PBKMG-51 4130 PBKMG-51 3030 PBKMG-51 120 120 120 120 120 120 120 120 120 120 120 120 120 120 277 277 277 277 277 277 277 277 277 277 277 277 9060 PBKMG-51 7560 PBKMG-51 6060 PBKMG-51 5060 PBKMG-51 4060 PBKMG-51 3060 PBKMG-51 15030 PBKMG-51 12030 PBKMG-51 9030 PBKMG-51 7530 PBKMG-51 6030 PBKMG-51 5030 PBKMG-51 4130 PBKMG-51 9060 PBKMG-51 7560 PBKMG-51 6060 PBKMG-51 5060 PBKMG-51 4060 PBKMG-51 Catalog Number VAC 9030 PBKMCG-51 7530 PBKMCG-51 6030 PBKMCG-51 5030 PBKMCG-51 4030 PBKMCG-51 4130 PBKMCG-51 120 120 120 120 120 120 120 120 120 120 120 277 277 277 277 9060 PBKMCG-51 7560 PBKMCG-51 6060 PBKMCG-51 5060 PBKMCG-51 4060 PBKMCG-51 9060 PBKMCG-51 7560 PBKMCG-51 6060 PBKMCG-51 5060 PBKMCG-51 Secondary Volts mA 15000 30 12000 30 9000 30 7500 30 6000 30 5000 30 4000 30 3000 30 9000 60 7500 60 6000 60 5000 60 4000 60 3000 60 Pri Input SECONDARY Wt. Hz VA Volts GROUND Lbs. L W 450 3.75 BMPG 20 11.500 5.130 60 360 3.00 BMPG 20 11.500 5.130 60 280 2.34 BMPG 12 10.125 3.776 60 225 1.88 UMPG 12 10.125 3.776 60 180 1.50 UMPG 11 10.125 3.776 60 160 1.34 UMPG 11 10.125 3.776 60 140 1.17 UMPG 8.500 3.776 9 60 100 8.500 OEG 9 .85 60 3.776 540 4.50 BMPG 21 15.125 3.766 60 450 3.75 BMPG 21 15.125 3.766 60 60 360 3.00 BMPG 15 11.875 3.766 60 300 2.50 BMPG 15 11.875 3.766 60 240 2.00 UMPG 11 10.125 3.766 60 180 1.50 UMPG 11 10.125 3.766 60 15000 30 450 1.63 BMPG 20 11.500 5.130 60 12000 30 360 1.30 BMPG 20 11.500 5.130 60 9000 30 280 1.01 BMPG 12 10.125 3.766 .81 UMPG 12 10.125 3.766 60 7500 30 225 60 6000 30 190 .69 UMPG 11 10.125 3.766 .58 UMPG 10 10.125 3.766 60 5000 30 160 60 4000 30 140 8.500 3.766 .51 UMPG 9 60 9000 60 540 1.95 BMPG 21 15.125 3.766 60 7500 60 420 1.63 BMPG 21 15.125 3.766 60 6000 60 370 1.34 BMPG 15 11.875 3.766 60 5000 60 300 1.08 BMPG 15 11.875 3.766 .87 UMPG 11 10.125 3.766 60 4000 60 240 HIGH POWER FACTOR Secondary PRI Input SECONDARY Wt. Hz GROUND Lbs. L Volts mA VA Amps W 60 9000 30 150 1.25 BMPG 13 11.875 3.625 60 7500 30 125 1.05 UMPG 13 11.875 3.625 .84 UMPG 13 11.875 3.625 60 6000 30 100 60 5000 30 90 .75 UMPG 13 11.875 3.625 75 .63 UMPG 12 10.125 3.625 60 4000 30 75 60 4100 30 .63 OEG 10 10.125 3.625 60 9000 60 250 2.50 BMPG 23 16.750 3.625 60 7500 60 300 2.09 BMPG 22 16.750 3.625 60 6000 60 200 1.67 BMPG 20 13.500 3.625 60 5000 60 170 1.42 BMPG 20 13.500 3.625 60 4000 60 135 1.13 UMPG 13 11.875 3.625 60 9000 60 250 1.09 BMPG 23 16.750 3.625 60 7500 60 300 .91 BMPG 22 16.750 3.625 60 6000 60 200 .73 BMPG 20 13.500 3.625 60 5000 60 170 .62 BMPG 20 13.500 3.625 Case Dimensions H 4.178 4.178 3.080 3.080 3.080 3.080 3.080 3.080 3.447 3.447 3.080 3.080 3.080 3.080 4.178 4.178 3.080 3.080 3.080 3.080 3.080 3.447 3.447 3.080 3.080 3.080 A 10.000 10.000 8.625 8.625 8.625 8.625 7.000 7.000 13.625 13.625 10.375 10.375 8.625 8.625 10.000 10.000 8.625 8.625 8.625 8.625 7.000 13.625 13.625 10.375 10.375 8.625 B 10.625 10.625 9.250 9.250 9.250 9.250 7.620 7.620 14.250 14.250 11.000 11.000 9.250 9.250 10.625 10.625 9.250 9.250 9.250 9.250 7.620 14.250 14.250 11.000 11.000 9.250 C 2.5 2.5 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 D 2.5 2.5 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 E 1.5 1.5 1.3 1.3 C 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 D 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 E 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 Case Dimensions H 3.080 3.080 3.080 3.080 3.080 3.080 3.447 3.447 3.072 3.072 3.080 3.447 3.447 3.072 3.072 A 10.375 10.375 10.375 10.375 8.625 8.625 B 11.000 11.000 11.000 11.000 9.250 9.250 15.250 15.250 12.000 12.000 10.375 15.250 15.250 12.000 12.000 15.875 15.875 12.625 12.625 11.000 15.875 15.875 12.625 12.625 BMPG = Balance Mid-Point Ground UMPG = Unbalanced Mid-point Ground OEG = One End Ground H A FRANCEFORMER .50 x .25 SLOT 4 PLCS D W C E Mounting 2268 Fairview Blvd w PO Box 300 w Fairview, TN 37062 voice 800-753-2753 w fax 615-799-3199 B L xs09013 5/12/09 Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation PBKMG -751 PBKMG -734 Outdoor Non-weatherproof Mini Internal Mount Electrode Housing PBKMG -734 PBKMG -751 u UL 2161 Recognized Component u Pre-wired Primary u Ideal for Shallow Profile Individual Self-Contained Letters u Small Case Size Allows for Small Spaces u Available in 2 Styles - 751 & 734 u Heavy Duty Steel Construction www.franceformer.com 2268 Fairview Blvd Click here to unlock PDFKit.NET PO Box 300 Fairview, TN 37062 voice 800-753-2753 fax 615-799-3199 Generated by PDFKit.NET Evaluation Non-weatherproof PBKMG -751 Outdoor Mini Internal Mount Electrode Housing PBKMG -734 NORMAL POWER FACTOR Catalog Number v v l v v l Secondary Volts mA 5000 4000 3000 5000 4000 3000 5030 PBKMG-734 4030 PBKMG-734 3030 PBKMG-734 5030 PBKMG-751 4030 PBKMG-751 3030 PBKMG-751 30 30 30 30 30 30 Primary Input Wt VA Amp lbs 7 7 7 7 7 7 1.34 1.17 85 1.34 1.17 .85 160 140 100 160 140 100 Dimensions in Inches L W H A 7.75 7.75 7.75 7.00 7.00 7.00 2.937 2.937 2.937 2.828 2.828 2.828 2.875 2.875 2.875 3.000 3.000 3.000 6.750 6.750 6.750 5.800 5.800 5.800 B 7.250 7.250 7.250 6.314 6.314 6.314 v Secondary - Unbalanced Mid-point Ground l Secondary - One End Ground PBKMG -734 PBKMG -751 A 1.0 H H 2.0 1.0 L B MTG L B MTG 2.0 W 1 1/2 1 1/2 2.0 W 5/16 DIA 4 HOLES DIM TO CENTER OF ELECTRODES 5/16 X 1/2 4 SLOTS 1.0 A email: france@franceformer.com xs09023 06/02/09 Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation The Power and the Light Save Time Simplify Production Sign Bright from France is recognized by sign builders everywhere as the best solution for HID sign illumination. This outof-the-box solution is convenient and affordable and will save time and energy on the factory floor. Time Saving We’ve done the work for you by pre-assembling the ballast, lampholder and diffuser in one convenient kit. All components are pre-wired to an integrated wiring compartment. Production Ready The Sign Bright is ready when you are. No more coordinating multiple components to come together on the factory floor for production. One part number assures you have everything you need, when you need it. Sign Ready High performance output with both 250W and 400W units, your sign illuminate evenly and deliver the lumen output your customer wants. The build in diffuser assures you get even light distribution. Click here to unlock PDFKit.NET www.franceformer.com Generated by PDFKit.NET Evaluation Sign Bright Line Current (A) Catalog & Part Number SBIP-250 18264 SBIP-400 18265 Watts Imput Power Operating Voltage Factor 250 120 208 240 277 400 120 208 240 277 Output Output Open Circuit Output Short Circuit Open Circuit Voltage Short Circuit Current Capacitor (uF/V) Wt. Lbs. >.85 2.50 1.45 1.25 1.10 2.65 - 3.25 1.35 - 1.80 1.15 - 1.50 1.00 - 1.35 0.75 - 1.55 0.40 - 1.00 0.40 - 0.80 0.30 - 0.70 280 - 340 2.25 - 2.75 15/400 18 >.85 4.00 2.30 2.00 1.70 2.50 - 3.80 1.60 - 2.30 1.50 - 2.10 1.20 - 1.75 1.75 - 3.25 1.00 - 1.85 0.70 - 1.50 0.65 - 1.40 270 - 330 3.50 - 4.30 24/400 20 The minimum recommended sign cabinet depth is 30” for SBIP and 36” for SBIP-400. For optimum heat dissipation, the recommended mounting is with lamp vertical as shown below. The lamps supplied are universal mount, but orienting any other direction could reduce the life of the ballast. The recommended horizontal and vertical lamp spacing is 4'0" for the SB400 and 3'0" for the SB250. Actual spacing may vary depending on cabinet size, cabinet depth, face substrate, face decoration and light output requirements. The Sign Bright case must be mounted on a steel member capable of supporting 20 lb. dead load. The 120 & 277 Volt leads are supplied in the writing compartment. The 208 and 240 Volt leads are provided in the ballast compartment and must be routed to the wiring compartment by the end user. xs09030 07/08/09 2268 Fairview Blvd | Fairview, TN 37062 | 800-753-2753 | www.franceformer.com Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation Fluorescent Lampholders For T12 Lamps WP-LH30-1 WP-LH82 WP-LH83 WP-LH30-2 For T8 Lamps WP-LH30-1BP WP-LH82BP w Rated 1000V/660 Watt for T8 & T12 Lamps WP-LH82BP, WP-LH30-2, w WP-LH82, WP-LH30-2BP are Stationary Mount WP-LH83BP, WP-LH30-1, w WP-LH83, WP-LH30-1BP are Spring Loaded 12 leads - 18 Awg/Awm - 1000V w Standard Stranded, stripped and pre-tinned. w 90°C Maximum end use application WP-LH83BP WP-LH30-2BP material is Lexan w Housing (UV resistance & flame retardent) quality Stainless Steel w High Spring on WP-LH83, WP-LH83BP, WP-LH30-1 & WP-LH-301BP w High strength metal retaining clips w Packaged - 250 per box www.westrimproducts.com xs09034 10/22/09 2268 Fairview Blvd w PO Box 300 w Fairview, TN 37062 w voice 800-423-1369 w fax 615-799-3199 Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation P5KA2NG -2UE ServiceMaster Universal Replacement Service Units Ever wish you had 8 arms? With the ServiceMaster you only need 2! True 30mA Output- The ServiceMaster can replace 8 ratings. Diagnostic Circuit- LED indicates the reason for service, allowing for quick, easy troubleshooting. Primary Wiring Requirements of a Non-SCGFP - with the added safety of Secondary Ground Fault Protection. Service Button - For easy troubleshooting of ground faults and primary wiring problems. Overrides the SCGFP for up to 30 minutes. Auto Reset - After secondary ground fault, automatically attempts to reset three times within ten seconds. Manual reset possible at any time by disconnecting primary power. Secondary Circuit Ground Fault Protection - (SCGFP) Disables unit upon detection of arcs to ground in compliance with UL2161 and NEC requirements. Easy Wiring Methods - Virtual Ground and Series Wiring Methods User Friendly - Adapts to most grounding situations. Features Include- Easy to carry handle; On/Off Toggle Switch; No transformer box required for interior installations. *Can be used in flashing/dimming applications. *UL does not have listing requirements for transformers that are rdemotely dimmed or flashed. www.franceformer.com Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation P5KA2NG -2UE ServiceMaster SERVICE MASTER REPLACES 15000, 12000 & 10500 Volt 9000, 7500, 6000, 5000, 4000, 3000 & 2000 Volt 15030 P5KA2NG-2UE 9030 P5KA2NG-2UE Diagnostic LED Operation DIAGNOSTIC LED OPERATION Indicates LED Fault Code Steady ON Continuous Flashing 1 - Flash 2 - Flash 3 - Flash 4 - Flash 5 - Flash Operating normally In Service Mode 15 second Diagnostic & Auto Reset Mode Secondary Ground Fault with service ground connected Secondary Ground Fault when service ground not connected Input Voltage exceeds 120% of rated Line & Neutral reversed on input connections Service Switch does not operate without proper grounding. A W NO PCB LED" INDICATOR Toggle Switch 20 amp 120V .940 ON OFF 1.49 H Service Button 3.35 L B (MTG) C .375 X .750 SLOT, 4 PLCS Catalog Number VAC Hz 15030 P5KA2NG-2UE 9030 P5KA2NG-2UE 15030 P5KA2NG-2UE 9030 P5KA2NG-2UE 120 120 277 277 60 60 60 60 NORMAL POWER FACTOR NORMAL POWER FACTOR Secondary Primary Input Wt. Amps Lbs. V.A. Volts mA L 15000 9000 15000 9000 30 30 30 30 510 330 530 320 4.25 2.75 1.90 1.15 25 17 25 17 13.35 13.35 13.35 13.35 W Case Dimensions H A B C 7.47 7.47 7.47 7.47 12.21 12.21 12.21 12.21 3.00 3.00 3.00 3.00 4.50 4.50 4.50 4.50 10.87 10.87 10.87 10.87 2268 Fairview Blvd w PO Box 300 w Fairview, TN 37062 w voice 800-753-2753 w fax 615-799-3199 xs09002 04/29/09 Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation EB25-120/277V EB45-120V EB45-277V EB65-120V EB65-277V T8 BALLASTS S P E C I F I C A T I O N S INPUT PARAMETERS 2-LAMP 4 -LAMP 6-LAMP E B 2 5 - 12 0 V / 2 7 7 V E B45-120V EB45-277V EB65-120V EB65-277V Nominal line voltage rating 120 – 277 volts 120 volts 277 volts 120 volts 277 volts Line voltage operating range 90 – 132 volts 90 – 132 volts 208 – 305 volts 90 – 132 volts 208 – 305 volts Maximum input current .90 A 1.50 A .65 A 2.60 A 1.20 A Power factor >90% >90% >90% >90% >90% Total harmonic distortion <10% <10% <10% <10% <10% FCC CFR Part 18 for RF Lighting Device. Non-consumer equipment FCC CFR Part 18 for RF Lighting Device. Non-consumer equipment FCC CFR Part 18 for RF Lighting Device. Non-consumer equipment FCC CFR Part 18 for RF Lighting Device. Non-consumer equipment FCC CFR Part 18 for RF Lighting Device. Non-consumer equipment >90% >90% >90% >90% >90% EMI requirements Electrical efficiency (at full load) Click here to unlock PDFKit.NET 2268 Fairview Blvd | Fairview, TN 37062 | 800-753-2753 | www.franceformer.com Generated by PDFKit.NET Evaluation S P E C I F I C A T I O N S EB25-120/277V • EB45-120V • EB45-277V • EB65-120V 2- LAM P 4- LA MP E B 2 5 - 12 0 V / 2 7 7 V E B45-120V • EB45-277V RMS open circuit voltage Less than 1000 volts Less than 1000 volts Less than 1000 volts Minimum/Maximum lamp load 3–10 ft ( e.g. 1 or 2 lamps ) 6 – 20 ft ( e.g. 3 or 4 lamps ) 10 – 30 ft ( e.g. 5 or 6 lamps ) Parallel Parallel Parallel Min. lamp length on any one output 3 ft 2 ft 2 ft Max. lamp length on any one output 5 ft 5 ft 5 ft -20° F (-29 °C) -20° F (-29 °C) -20° F (-29 °C) No No No Height 1.2 inches 1.8 inches 1.8 inches Width 1.625 inches 2.625 inches 2.625 inches Length 9.438 inches 10.2 inches 14.25 inches Weight 1.50 lb 3.30 lb 5.05 lb Painted steel, white Painted steel, white Painted steel, white 1 Black, 1 White, each 2 feet long 1 Black, 1 White, each 2 feet long 1 Black, 1 White, each 2 feet long 1 red common, 2 corresponding blue, each AWG 18 solid, 8 feet out of case 2 blue, 2 red with two yellow commons, each AWG 18 solid, 10 feet out of case 3 blue with corresponding yellow common, 3 red with corresponding yellow/black common, each AWG 18 solid, 12 feet out of case cULus cULus cULus Operating temperature range -30° to 65°C -30° to 65°C -30° to 65°C Storage temperature -30° to 85°C -30° to 85°C -30° to 85°C OUTPUT PARAMETERS Lamps configuration Low temperature starting Externally dimmable Enclosure material Input leads Output leads Agency certifications Warranty 6-LA MP • EB65-277V COMM EN TS EB65-120V • EB65-277V Includes base plate. Reference only Outdoor Type 2 France warrants the Reliant ballasts to be free from defects in manufacturing and workmanship for a period of four years from the date of manufacture. When used with Westrim T8 lamp holders, France warrants the product for five (5) years. xs09011 05/01/06 Click here to unlock PDFKit.NET 2268 Fairview Blvd | Fairview, TN 37062 | 800-753-2753 | www.franceformer.com Generated by PDFKit.NET Evaluation INTRODUCING THE FRANCE T8 RELIANT FLUORESCENT LIGHTING SYSTEM 10 YEAR LIFE EXPECTANCY Up to 4 times longer life than standard T12 lamps, based on a normal-duty cycle usage of 12 hours per day. VIRTUALLY ELIMINATES SERVICE CALLS Save hundreds of dollars in service calls for lamp replacements. Three fewer service calls at $125 each for replacements equals a savings of $375 per sign. HEAVY-DUTY T8 LAMP SOCKETS Specially designed for the sign industry, the T8 Reliant lamp sockets are interchangeable with T12 standard sockets for easy retrofitting of existing signs. UNIQUE SIGN LENGTH LAMPS The T8 Reliant lamps come in the same length as standard T12 HO, making it easy to retrofit T12 applications. PATENTED LIGHT DIFFUSION The T8 Reliant lamp features light diffusion in the outer tube for closer spacing of lamps to the face without hot spots. Fewer T8 lamps required due to spacing on 18 centers compared to 12 centers for T12 lamps. Cabinet depth can be reduced by 2. COLD CLIMATE CHARACTERISTICS Patented Cold Climate CC products assure starting and superior light output at temperatures as low as -30L C (20L F). HIGH-ENERGY EFFICIENT T8 DESIGN Uses up to 30% less energy than T12 HO lamps, providing a payback on energy efficiency in about one year. ENVIRONMENTALLY FRIENDLY Up to 90% less mercury to depose of during product life cycle. Uses 1/3 less mercury per lamp with 4 times longer life using 1/3 fewer lamps. TRUE COLOR RENDERING Excellant color rendering index of 80-85 CRI. T8 Reliant Click here to unlock PDFKit.NET ® Generated by PDFKit.NET Evaluation F luor escent T8 Lamps T8 Reliant Fluorescent Lamps - 4500K White Plus CRI - 85 Catalog # * F24 T8 - LL / WP F36 T8 - LL / WP F48 T8 - LL / WP F60 T8 - LL / WP F72 T8 - LL / WP F84 T8 - LL / WP F96 T8 - LL / WP Description 24 T8 Fluorescent Lamp Long Life 36 T8 Fluorescent Lamp Long Life 48 T8 Fluorescent Lamp Long Life 60 T8 Fluorescent Lamp Long Life 72 T8 Fluorescent Lamp Long Life 84 T8 Fluorescent Lamp Long Life 96 T8 Fluorescent Lamp Long Life White Plus White Plus White Plus White Plus White Plus White Plus White Plus Watts 18 24 32 40 48 56 64 * F24 T8 Lamps are 1 3/8 longer than sign length T12 HO Lamps. All other Lamps use sign length spacings. T8 Reliant Fluorescent Lamps - 6500K Daylight CRI - 85 Catalog # * F24 T8 - LL / DL F36 T8 - LL / DL F48 T8 - LL / DL F60 T8 - LL / DL F72 T8 - LL / DL F84 T8 - LL / DL F96 T8 - LL / DL Description 24 T8 Fluorescent Lamp Long Life 36 T8 Fluorescent Lamp Long Life 48 T8 Fluorescent Lamp Long Life 60 T8 Fluorescent Lamp Long Life 72 T8 Fluorescent Lamp Long Life 84 T8 Fluorescent Lamp Long Life 96 T8 Fluorescent Lamp Long Life Daylight Daylight Daylight Daylight Daylight Daylight Daylight Watts 18 24 32 40 48 56 64 T8 Reliant Fluorescent Lamps - 4500K White Plus CRI - 85 Catalog # Description Watts * F24 T8 - CC / WP 24 T8 Fluorescent Lamp 36 T8 Fluorescent Lamp 48 T8 Fluorescent Lamp 60 T8 Fluorescent Lamp Cold Climate Cold Climate Cold Climate Cold Climate * F24 T8 - CC DA/WP 24 T8 Fluorescent Lamp 36 T8 Fluorescent Lamp 48 T8 Fluorescent Lamp 60 T8 Fluorescent Lamp Cold Climate Dual Diffusion Type A Cold Climate Dual Diffusion Type A Cold Climate Dual Diffusion Type A Cold Climate Dual Diffusion Type A White Plus White Plus White Plus White Plus 18 24 32 40 * F24 T8 - CC DB/WP 24 T8 Fluorescent Lamp 36 T8 Fluorescent Lamp 48 T8 Fluorescent Lamp 60 T8 Fluorescent Lamp Cold Climate Dual Diffusion Type B Cold Climate Dual Diffusion Type B Cold Climate Dual Diffusion Type B Cold Climate Dual Diffusion Type B White Plus White Plus White Plus White Plus 18 24 32 40 F36 T8 - CC / WP F48 T8 - CC / WP F60 T8 - CC / WP F36 T8 - CC DA/WP F48 T8 - CC DA/WP F60 T8 - CC DA/WP F36 T8 - CC DB/WP F48 T8 - CC DB/WP F60 T8 - CC DB/WP White Plus Non-Diffused White Plus Non-Diffused White Plus Non-Diffused White Plus Non-Diffused 18 24 32 40 *F24 T8 Lamps are 1 3/8 longer than sign length T12 HO Lamps. All other Lamps use sign length spacings. Catalog # T8 Reliant Fluorescent Lamps - 6500K Daylight CRI - 85 Description Watts * F24 T8 - CC / DL 24 T8 Fluorescent Lamp 36 T8 Fluorescent Lamp 48 T8 Fluorescent Lamp 60 T8 Fluorescent Lamp Cold Climate Cold Climate Cold Climate Cold Climate * F24 T8 - CC DA/DL 24 T8 Fluorescent Lamp 36 T8 Fluorescent Lamp 48 T8 Fluorescent Lamp 60 T8 Fluorescent Lamp Cold Climate Dual Diffusion Type A Cold Climate Dual Diffusion Type A Cold Climate Dual Diffusion Type A Cold Climate Dual Diffusion Type A Daylight Daylight Daylight Daylight 18 24 32 40 * F24 T8 - CC DB/DL 24 T8 Fluorescent Lamp 36 T8 Fluorescent Lamp 48 T8 Fluorescent Lamp 60 T8 Fluorescent Lamp Cold Climate Dual Diffusion Type B Cold Climate Dual Diffusion Type B Cold Climate Dual Diffusion Type B Cold Climate Dual Diffusion Type B Daylight Daylight Daylight Daylight 18 24 32 40 F36 T8 - CC / DL F48 T8 - CC / DL F60 T8 - CC / DL F36 T8 - CC DA/DL F48 T8 - CC DA/DL F60 T8 - CC DA/DL F36 T8 - CC DB/DL F48 T8 - CC DB/DL F60 T8 - CC DB/DL Daylight Non-Diffused Daylight Non-Diffused Daylight Non-Diffused Daylight Non-Diffused 18 24 32 40 The Power and the Light Click here to unlock PDFKit.NET Generated by PDFKit.NET Evaluation T12 EL ECT R O N I C S I G N EB1228-120V EB1228-277V EB1248-120V EB1248-277V EB1268-120V EB1268-277V B A LL A S T S P E C I F I C A T I O N S INPUT PARAMETERS 2-LAMP 4 -LAM P 6-LAMP 12 0 V 277V 120V 277V 120V 277V Nominal line voltage rating 120 volts, 50/60 Hz 277 volts, 50/60 Hz 120 volts, 50/60 Hz 277 volts, 50/60 Hz 120 volts, 50/60 Hz 277 volts, 50/60 Hz Line voltage operating range 90 to 132 volts 208 to 305 volts 90 to 132 volts 208 to 305 volts 90 to 132 volts 208 to 305 volts Nominal input current 1.2A .6A 2.2A 1.0A 4.0A 1.7 A Power factor >90% >90% >90% >90% >90% >90% Total harmonic distortion <10% <10% <10% <10% <10% <10% FCC 47 CFR Part 18 for RF Lighting Device, Nonconsumer equipment FCC 47 CFR Part 18 for RF Lighting Device, Nonconsumer equipment FCC 47 CFR Part 18 for RF Lighting Device, Nonconsumer equipment FCC 47 CFR Part 18 for RF Lighting Device, Nonconsumer equipment FCC 47 CFR Part 18 for RF Lighting Device, Nonconsumer equipment FCC 47 CFR Part 18 for RF Lighting Device, Nonconsumer equipment >90% >90% >90% >90% >90% >90% EMI requirements Electrical efficiency (at full load) Click here to unlock PDFKit.NET 2268 Fairview Blvd | Fairview, TN 37062 | 800-753-2753 | www.franceformer.com Generated by PDFKit.NET Evaluation S P E C I F I C A T I O N S EB1228-120V • EB1228-277V • EB1248-120V • EB1248-277V • EB1268-120V • EB1268-277V 2 -LAM P 4-LAMP 6-LAMP RMS open circuit voltage Less than 1000 volts Less than 1000 volts Less than 1000 volts Minimum/Maximum lamp load 2 –16 ft ( e.g. 1 or 2 lamps ) 6–32 ft ( e.g. 3 or 4 lamps ) 6–48 ft ( 3, 4, 5 or 6 lamps ) Parallel Parallel Parallel Min. lamp length on any one output 2 ft 2 ft 2 ft Max. lamp length on any one output 8 ft 8 ft 8 ft -20° F (-29 °C) -20° F (-29 °C) -20° F (-29 °C) No No No Height 1.8 inches 1.8 inches 1.8 inches Reference only Width 2.6 inches 2.6 inches 2.6 inches Reference only Length 10.25 inches 14.25 inches 14.25 inches Includes base plate. Reference only 1.5 lb 2.5 lb 2.5 lb Painted steel, white Painted steel, white Painted steel, white 1 Black, 1 White, each 2 feet long 1 Black, 1 White, each 2 feet long 1 Black, 1 White, each 2 feet long 1 red common, 2 corresponding blue, each AWG 18 solid, 8 feet out of case 2 blue with corresponding yellow common, 2 red with corresponding yellow/black common, each AWG 18 solid, 10 feet out of case 3 blue with corresponding yellow common, 3 red with corresponding yellow/black common, each AWG 18 solid, 12 feet out of case cULus cULus cULus Operating temperature range -30° to 65°C -30° to 65°C -30° to 65°C Storage temperature -30° to 85°C -30° to 85°C -30° to 85°C Lamps configuration Low temperature starting Externally dimmable Total weight Enclosure material Input leads Output leads Agency approvals Warranty C OMMENT S Less than 600 volts to ground – may use 600 volt ballast wire Outdoor Type 1 France warrants the Powerbrite ballasts to be free from defects in manufacturing and workmanship for a period of four years from the date of manufacture. When used with Westrim T12 lamp holders, France warrants the product for five (5) years. xs09012 02/01/06 Click here to unlock PDFKit.NET 2268 Fairview Blvd | Fairview, TN 37062 | 800-753-2753 | www.franceformer.com