Eye Doctor Datasheet
Transcription
Eye Doctor Datasheet
EYE DOCTOR™ Leading Features • Full signal integrity analysis of equalized receiver signal • Real time co-simulation of measured signals and measured or modeled network characteristics • Performance margin analysis in equalized systems • De-embedding of fixture and probe responses • High accuracy far-end channel measurements • Emulates any combination of DFE and FFE equalizers • Automatic equalizer coefficient optimization • Direct entry of FFE and DFE coefficients Virtual Probing™ and equalizer emulation enhance the capability of the SDA to allow the measurement of serial data signals in equalized systems have increased, the measurement Measuring Equalized Systems challenges have also and with the Imperfections such as through adoption of receiver equalization, holes, connectors, vias and package traditional jitter and noise measure- pins cause distortions in the high ments are becoming inadequate frequency content of high bit rate for determining interoperability. signals. The resulting eye is often Eye Doctor™ is a DSO-based closed or nearly closed. The tradi- instrumentation and simulation tional approach to interoperability system which addresses these testing involves measuring the measurement challenges and is channel response and the transmit- a dramatic leap in interoperability ter signal quality against compliance and compliance testing capability. masks designed so that the signal As the symbol rates of systems Eye Doctor provides the tools to undo or compensate many common forms of distortion thereby increasing signal to noise, opening eyes, increasing rise time, reducing jitter restoring lost bandwidth and improving waveform fidelity. eye and jitter will enable error-free operation. In an equalized system, the channel, transmitter and receiver are closely coupled and interoperability is determined by whether the signal can be equalized. What is needed is a method to quantitatively measure the interoperability of these systems. Tools for Next Generation Serial Data Analysis Current generation serial data systems ensure interoperability using compliance measurements. Next generation systems employing equalization require new methods for determining interoperability. With the signal eye closed, traditional compliance measurements are no longer sufficient. Eye Doctor Virtual Probing available, usually at the transmitter, Eye doctor consists of two Probes and fixtures are not perfect and the corrupted signal at the elements; Virtual Probing™ and and their presence in the circuit far-end of the channel (at the end equalized receiver emulation. impacts both the loading on the of the backplane) can be simulated Virtual Probing enhances the DUT as well as the waveform seen thus eliminating probe and instru- accuracy of measurements by the oscilloscope. Virtual Probing ment noise from the measurement. made on distorted waveforms is a powerful signal processing tool The derived filter takes into account while equalized receiver emulation which enables the user to measure all of the interactions among the allows measurements to be made a signal anywhere within a system elements of the system and trans- from a “receivers eye view.” and then project a response at any mitter signal including differential The ideal view of the signal within other desired point. This feature to common mode conversion, near- the receiver allows accurate total works by using S-parameter files end and far-end crosstalk. jitter and bit error rate measurements of the various components in the Virtual Probing can be used to that are representative of actual system to derive a filter which de-embed probe and fixture responses system performance. relates the desired measured signal from measurements thereby improv- to the acquired waveform. For ing the accuracy of signal integrity example, measurements can be measurements. made where the cleanest signal is 2 Equalizer Emulation Eye Doctor features equalized receiver emulation which includes both Feed Forward Equalization (FFE) and Decision Feedback Equalization (DFE) along with clock recovery and a variable decision Equalizer emulation simulates the signal as viewed within the receiver. The component can automatically determine the optimum weighting coefficients for both FFE and DFE with the number of taps for each selected by the user. Coefficients can also be entered directly. The full jitter analysis capability of the SDA is available on the equalized signal. threshold. This ideal receiver reveals the signal as seen within a real receiver at the detector where it is impossible to probe. The equalized signal can be measured using the powerful jitter and signal analysis software in the SDA allowing the bit error rate, total jitter, and eye opening to be measured thus giving a precise indication of the performance margin. Because the receiver emulation is ideal, the margins are measured independently of measurement system and receiver noise. Virtual Probing simulates signals from any point within the system using a single measured waveform. The virtual probe shown here is co-simulating a backplane which closes the eye. The equalizer corrects the distortion caused by the backplane which opens the eye. The Processing Web Editor is used to connect the equalizer and Virtual Probing elements in an intuitive signal flow diagram layout. 3 Specifications Equalizer Emulation Virtual Probing • Up to 20 tap linear tapped delay line equalizer (transversal filter). • Provides waveforms that compensate for probe loading effects within bandwidth limitations of the system. • PLL for clock recovery with variable loop bandwidth. • Produces linear filters that operate on up to 8 inputs and provides up to 8 outputs. • Up to 20 tap Decision Feedback Equalizer (DFE) including erasure DFE. • Simple text file system description similar to Spice. • Accepts Touchstone format S-parameter file network device descriptions. • Clock skew adjustment. • Outputs for equalized waveform (slicer input), data waveform (slicer output), and recovered clock. • Includes simple device descriptions such as ideal tees, power splitter, open, short, thru plus lumped elements such as resistors, capacitors and inductors. • Error waveform output for user defined equalizer optimizations. • Automatic blind adaptation using built-in LMS algorithms. • Multi-level detection threshold supports duobinary and multilevel signaling systems. Ordering Information Customer Service Eye Doctor is optional on the following SDA and WaveExpert models • Serial Data Analyzers SDA 6000A, SDA 6020, SDA 9000, SDA 11000, SDA 18000 • SDA 100G, NRO 9000 and WaveExpert 100H Product Description Eye Doctor (Virtual probe and equalizer emulation bundle) Virtual Probe Equalizer Emulation Retrofit Kit for Eye Doctor (Virtual probe and equalizer emulation bundle) Retrofit Kit for Virtual Probe Retrofit Kit for Equalizer Emulation Product Code EYEDR EYEDR-VP EYEDR-EQ LeCroy oscilloscopes are designed, built, and tested to ensure high reliability. In the unlikely event you experience difficulties, the WaveExpert Series oscilloscopes and modules are warranted for a period of one year, and our probes are warranted for one year. The SDA Series Serial Data Analyzers are fully warranted for three years. This warranty includes: • No charge for return shipping • Long-term 7-year support • Upgrade to latest software at no charge RK-EYEDR RK-EYEDR-VP RK-EYEDR-EQ 1-800-5-LeCroy www.lecroy.com Local sales offices are located throughout the world. To find the most convenient one visit www.lecroy.com © 2007 by LeCroy Corporation. All rights reserved. Specifications, prices, availability, and delivery subject to change without notice. Product or brand names are trademarks or requested trademarks of their respective holders. EyeDrDS_W2_10July07