Kewaunee Fume Hoods Lit. No. 11030
Transcription
Kewaunee Fume Hoods Lit. No. 11030
VWR Furniture Complete Dedicated Furniture Solutions Factory trained VWR Furniture Specialists work in coordination with VWR sales representatives to help you select the most functional and costeffective solutions for your lab. They will closely monitor inventory of top-quality furniture and components, as well as provide complete project supervision from proposal through installation. • VWR Furniture Project Estimators help you identify your lab furniture requirements and provide a comprehensive quote of your project’s cost • VWR Furniture Design Specialists create lab plans to suit your specifications using the latest computer aided design (CAD) software • VWR Project Coordinators manage every detail including ordering, shipping, and final installation • VWR Furniture Installers have extensive experience and knowledge of our product line, insuring a fast, trouble-free finish to your project To learn more about VWR Furniture Products, Services, and Customer Support visit vwr.com today! 0811 (10M) Lit. No. 11030 KEWAUNEE Supreme Air Series Fume Hoods Supreme Air Fume Hood Construction Supreme Air Fume Hood Technical Data The Supreme Air Fume Hood design is based on rigid frame construction that assures solid installation and low vibration and sound levels. Access panels are easily removable to access service lines and fittings. Radius corner posts and airfoils, plus fixed interior baffle settings assure a high level of comfort, safety and efficiency. Supreme Air Fume Hood Wiring Diagram With a variety of models available and selected option packages, this new generation of fume hoods can be tailored to the application needs of your modern laboratory. Aesthetically pleasing curved airfoils, contemporary controls and devices, and an eye-pleasing light neutral color, make this hard-working laboratory safety device an attractive part of the total laboratory environment. Excellent interior lighting • Single tube, low profile,T5 fluorescent light fixture • Tube replacement from outside of hood KMER modified epoxy resin liner • 1/4" thick, solid, light neutral colored liner • Class A fire rating • Low profile, self-gasketing, interior access panel — removable without tools • Stainless steel liner for Isotope and Perchloric Acid Hoods Customizable accessory offerings • A full array of service fittings • Monitoring safety alarm available Prewired light and receptacles • UL listed per UL 3101-1 1993 Low profile PVC sash tracks • Smooth sash operation • Reduced air turbulence • Seals the interior side panel Easy-to-operate full vision sash with: • Full length painted aluminum handle for neat, clean appearance and streamlined air features • Exclusive sash leveling and alignment features Independent frame construction • Rigid structural frame • Allows liner panel replacement • Stainless steel fasteners concealed with corrosionresistant caps Narrow-radiused corner posts • Enhances aerodynamic air flow • 4" width creates more interior work space Radiused air foil • Streamline air flow — low turbulence • Heavy gauge stainless steel for durability Exclusive Kemresin work tops • Dished black epoxy resin worksurface available • Integral stainless steel worksurface in Isotope and Perchloric Acid hoods Specialized base cabinets • UL listed solvent storage cabinets • One-piece polyethylene lined acid storage cabinets • Vacuum pump storage cabinets • Cabinets available in both wood and steel SQUARE D THERMAL UNIT SIZING The fan switch requires the installation of a Square D Thermal unit to function. The thermal unit is not supplied with the switch as it must be selected based on the full load amperage of the fan motor. Motor Full-load Current Amperes 0.41 - 0.44 0.45 - 0.49 0.50 - 0.53 0.54 - 0.58 0.59 - 0.65 0.66 - 0.71 0.72 - 0.78 0.79 - 0.85 0.86 - 0.96 0.97 - 1.04 1.05 - 1.16 Thermal Unit No. A .49 A .54 A .59 A .65 A .71 A .78 A .86 A .97 A 1.02 A 1.16 A 1.25 Motor Full-load Current Amperes 1.17 - 1.29 1.30 - 1.37 1.38 - 1.47 1.48 - 1.56 1.57 - 1.65 1.66 - 1.79 1.80 - 1.95 1.96 - 2.15 2.16 - 2.38 2.39 - 2.75 2.76 - 2.84 Thermal Unit No. A 1.39 A 1.54 A 1.63 A 1.75 A 1.86 A 1.99 A 2.15 A 2.31 A 2.57 A 2.81 A 3.61 Motor Full-load Current Amperes 2.85 - 3.06 3.07 - 3.45 3.46 - 3.70 3.71 - 4.07 4.08 - 4.32 4.33 - 4.90 4.91 - 5.35 5.36 - 5.85 5.86 - 6.41 6.42 - 6.79 6.80 - 7.57 Thermal Unit No. A 3.95 A 4.32 A 4.79 A 5.30 A 5.78 A 6.20 A 6.99 A 7.65 A 8.38 A 9.25 A 9.85 Motor Full-load Current Amperes 7.58 - 8.15 8.16 - 8.98 8.99 - 9.67 9.68 - 9.95 9.96 - 10.8 10.9 - 12.1 12.2 - 13.1 13.2 - 13.9 14.0 - 15.0 15.1 - 16.0 Thermal Unit No. A 11.0 A 11.9 A 13.2 A 14.1 A 14.8 A 16.2 A 17.9 A 19.8 A 21.3 A 25.2 How to Order a Fume Hood 1 Select Fume Hood Type and Size General Purpose Bench Hood 4ft 5ft 6ft 8ft page 2 4ft 5ft 6ft page 3 4ft 5ft 6ft page 5 4ft 5ft 6ft page 6 6ft page 4 High Performance Bench Hood Isotope Bench Hood Perchloric Acid Bench Hood General Purpose Walk-in Hood 2 Select Work Top and Cup Sink Standard Work Top page 11 4ft 5ft 6ft 8ft Work Top with Vent Hole page 11 4ft 5ft 6ft 8ft 3 Steel Cabinets Stack Head (required only if using Air Chamber) 4 Select Cabinet Trim Steel Cabinet Trim see page 16 4ft-6ft Hood Exhaust Fan see page 16 5 Isotope Hood Fittings see page 16 see page 16 1 page 10 page 10 Air Gas Vac CW DW CW Gooseneck Exhaust Duct see page 7 Select Service Fittings Air Gas Vac CW DW CW Gooseneck (required only if using Air Chamber) Auxiliary Air Chamber (optional) page 9 8ft hood Standard Fittings Auxiliary Air Duct 6 page 8 General Acid Storage Solvent Vac Pump see page 16 Auxiliary Air Fan Select Base Storage Cabinets Airflow Alarm 6 Other Options Auxiliary Air Chamber Restricted By-pass page 11 when required page 7 page 7 Fume Hood see page 2-6 5 Service Fittings see page 10 2 Work Top see page11 3 Base Cabinets see page 8-9 4 Cabinet Trim see page 9 1 Supreme Air Fume Hoods REDISHIP General Purpose Bench Hood Specifications Supreme Air General Purpose Bench Hoods are furnished with Kewaunee’s Modified Epoxy Resin (KMER) lining and baffles, with fixed open center, upper, and lower exhaust slots. Hoods are complete with a Type 304 stainless steel lower deflector vane; counterbalanced, frameless sash of 1/4” combination safety glass; a full length handle; interior plumbing access panels; and louvered top front panel. Hood exteriors are fabricated of cold rolled steel, phosphate coated with a baked chemical resistant, synthetic resin, light neutral color finish.. Polyethylene exhaust duct collar is 1115/16” O.D. Supreme Air Genearl Purpose Bench Hoods may be fitted with a Restricted By-pass panel for use with VAV exhaust systems or may be equipped with an Auxiliary Air Chamber. Accessories Include: Two 120 volt AC 20 amp GFI duplex receptacles,single-tube, T5, fluorescent light fixture (tube included) with 20 amp light switch, and a motor rated fan switch (thermal unit not provided). Devices are wired to junction boxes mounted at the top exterior of the hood. Additional Parts Required for Complete Fume Hood Assembly Work Top page 11 Base Cabinets page 8 Service Fittings page 10 DIMENSIONS HEIGHT Overall Dimensions 893/4" ** Sash Opening 28" * Work Top 37" ** Clearance (sash up) 97" ** page 11 page 16 Cupsink Fan/Blower LENGTH 48" 40" 40" ... 60" 52" 52" ... 72" 64" 64" ... 96" 88" 88" ... Optional Accessories: Each front post and interior end liner is punched for remote control service fittings (5 left side, 4 right side). The right hand post is punched for an Air Alert 300 Alarm and is furnished with a cover plate. Service fittings, alarm, fan, work top, cupsink, and base units must be ordered separately. DEPTH Overall Hood Length Sash Opening Sq. Ft. 80 FPM 36" ... 251/2" ... 4'-0"/48" 5'-0"/60" 6'-0"/72" 8'-0"/96" 8.1 10.5 12.9 17.7 650 840 1040 1420 *Sash opening height above airfoil. Add 1" to calculate sash opening area. Total CFM and Static Pressure 100 120 S.P. FPM S.P. FPM S.P. 0.15" 810 0.25" 980 0.20" 1050 0.30" 1260 0.25" 1290 0.40" 1550 0.15" 1770 0.25" 2130 0.35" 0.45" 0.60" 0.35" Static pressures shown are for the pressure drop through the hoods only. The total pressure drop through the hood and the duct system must be calculated to select the proper exhaust fan. General Purpose Bench Fume Hoods — Vertical Rising Sash 4'-0" KS-05K5448 Auxiliary Air 5'-0" 6'-0" 8'-0" KS-05K5460 KS-05K5472 KS-05K5496 End View General Purpose fume hoods can be converted to Auxiliary Air Hoods by adding an Auxiliary Air Chamber. See page 7. Restricted By-pass (for VAV exhaust systems) General Purpose fume hoods may be converted to a Restricted By-pass model for use with VAV exhaust systems. See page 7. 2 Supreme Air LV Fume Hoods REDISHIP High Performance Bench Hood Specifications Supreme Air LV High Performance Bench Hoods are furnished with Kewaunee’s Modified Epoxy Resin (KMER) lining and unique interstitial, vertical slot baffles. Each fume hood is complete with a Type 304 stainless steel lower deflector vane, counterbalanced, self-closing (to 18"), frameless sash of 1/4" combination safety glass and interior plumbing access panels. Hood exteriors are fabricated of cold rolled steel, phosphate coated with a baked chemical resistant, synthetic resin, light neutral color finish. The exhaust duct collar is polyethylene, 1115/16" O.D. Supreme Air LV High Performance Bench Hoods are not designed for use with auxiliary air chambers. Accessories Include: Two 120 volt AC 20 amp GFI duplex receptacles,single-tube, T5, fluorescent light fixture (tube included) with 20 amp light switch, and a motor rated fan switch (thermal unit not provided). Devices are wired to junction boxes mounted at the top exterior of the hood. Optional Accessories: Each front post and interior end liner is punched for up to five (5) remote control service fittings.Service fittings, fan, work top, cupsink, and base units must be ordered separately. Additional Parts Required for Complete Fume Hood Assembly Work Top page 11 Base Cabinets page 8 Service Fittings page 10 Cupsink Fan/Blower page 11 page 16 DIMENSIONS Overall Demension Work Top Clearance (sash up) Height Length Depth 893⁄4" 37" 103" 48" 60" 72" 39" 51" 63" ... 363⁄4" 24" Airflow Requirements Overall Hood Width Square Foot Opening at 28" Sash Opening * 4'-0"/48" 5'-0"/60" 6'-0"/72" 7.85 10.27 12.69 Square Foot Opening at 18" Sash Opening * 5.15 6.73 8.31 HIGH SETTING 100 FPM at 18" 66 FPM at 28" CFM SP MEDIUM SETTING 84 FPM at 18" 55 FPM at 28" CFM SP LOW SETTING 55 FPM at 18" 28" not recommended CFM SP 515 675 830 430 565 700 285 370 460 0.20 0.20 0.25 0.15 0.15 0.20 0.10 0.12 0.15 * Includes free area contributions from sash clearance spaces and bypass opening. Static pressures shown are for the pressure drop through the hoods only. The total pressure drop through the hood and the duct system must be calculated to select the proper exhaust fan. High Performance Low Velocity Bench Fume Hoods — Self-closing Vertical Rising Sash 4'-0" 5'-0" 36 3/4 " 6'-0" 54" 89 3/4 " 35 3/4 " 97005-998 97006-000 97006-002 End View 3 Supreme Air Fume Hoods General Purpose Walk-in Hood Specifications Designed to sit directly on the floor and use the laboratory floor as the bottom work surface. Complete with Kewaunee’s Modified Epoxy Resin (KMER) lining and baffles, with fixed open middle, upper, lower, and center exhaust slots. Each walk-in hood is furnished with two counterbalanced, frameless sashes of 1/4" thick combination safety glass; interior plumbing access panels; full length sash handles; and a louvered top front panel. Hood exterior made of cold rolled steel. Finish is light neutral color. Polyethylene exhaust duct collar is 1115/16” O.D. Accessories Include: Two 120 volt AC 20 amp GFI duplex receptacles, single-tube, T5, fluorescent light fixture (tube included) with 20 amp light switch, and motor rated fan switch (thermal unit not provided). Devices are wired to junction boxes mounted at the top exterior of the hood. Optional Accessories: Each front post and interior end liner is punched for remote control service fittings (5 left side, 4 right side). The right hand post is punched for an Air Alert 300 Alarm and is furnished with a cover plate. Service fittings, alarm, and fan must be ordered separately. Additional Parts Required for Complete Fume Hood Assembly Service Fittings page 10 Fan/Blower page 16 DIMENSIONS HEIGHT LENGTH DEPTH Overall Dimensions Sash Opening Work Floor Clearance (sash up) 893/4" 28"* ... 103" 72" 64" 64" ... 36" ... 241/2" ... * Upper sash opening height above lower sash. Add 1" in height to calculate sash opening area. Optional Kemresin Hood Floor is available by special request. Contact your VWR furniture specialist for more information. Overall Hood Length Sash Opening Sq. Ft. 6'-0"/72" 12.9* 80 FPM Total CFM and Static Pressure 100 120 S.P. FPM S.P. FPM S.P. 1040 0.25" 1290 0.40" 1550 0.60" * Includes Upper Sash Opening only and 1" opening below lower sash. Static pressures shown are for the pressure drop through the hoods only. The total pressure drop through the hood and the duct system must be calculated to select the proper exhaust fan. General Purpose Walk-in Fume Hoods — Vertical Rising Sash 6'-0" KS-30K9072 End View Auxiliary Air General Purpose fume hoods can be converted to Auxiliary Air Hoods by adding an Auxiliary Air Chamber. See page 7 Restricted By-pass (for VAV exhaust systems) General Purpose fume hoods may be converted to a Restricted By-pass model for use with VAV exhaust systems. See page 7. 4 Supreme Air Fume Hoods Isotope Bench Hood Specifications Designed primarily for use with radiochemicals. Features coved corner and seamless welded Type 304 stainless steel work top with intersecting rear and interior end panels for ease of cleaning and decontamination. Complete with a Type 304 stainless steel lining and baffle, with fixed center, upper, and lower exhaust slots. Furnished with a Type 304 stainless steel lower deflector vane; a counterbalanced, frameless sash of 1/4" laminated safety glass; a full length sash handle; and a louvered top front panel. Exterior fabricated of cold rolled steel. Finish is light neutral color. Type 316 stainless steel exhaust duct collar is 1115/16" O.D. Accessories Include: Two 120 volt AC 20 amp GFI duplex receptacles, single-tube, T5, fluorescent light fixture (tube included) with 20 amp light switch, and a motor rated fan switch (thermal unit not provided). Devices are wired to junction boxes mounted at the top exterior of the hood. Optional Accessories: Each front post and interior end liner is punched for front load remote control service fittings (5 left side, 4 right side). The right hand post is punched for an Air Alert 300 Alarm and is furnished with a cover plate. Service fittings, alarm, fan, and base units must be ordered separately. Additional Parts Required for Complete Fume Hood Assembly Base Cabinets page 8 Service Fittings page 10 DIMENSIONS HEIGHT Overall Dimensions 893/4" ** Sash Opening 28" * Work Top 37" ** Clearance (sash up) 97" ** page 16 Fan/Blower LENGTH 48" 40" 40" ... 60" 52" 52" ... DEPTH 72" 64" 64" ... 36" ... 251/2" ... *Sash opening height above airfoil. Add 1" to calculate sash opening area. **Subtract 1" in height if wood base cabinets are used. Type 304 Stainless Steel Linings: Interior fume hood lining and baffles are 16-gauge, Type 304 stainless steel. The seamless welded 14-gauge, Type 304 stainless steel work top is dished 1/2" to retain spillage, and has an integrally welded 5" diameter cupsink at the left rear. (Work tops are not available with vent holes for use with acid storage base cabinets.) Overall Hood Length Sash Opening Sq. Ft. 4'-0"/48" 5'-0"/60" 6'-0"/72" 8.1 10.5 12.9 Total CFM and Static Pressure 80 100 120 FPM S.P. FPM S.P. FPM S.P. not recommened 810 0.25" 980 0.35" not recommened 1050 0.30" 1260 0.45" not recommened 1290 0.40" 1550 0.60" Static pressures shown are for the pressure drop through the hoods only. The total pressure drop through the hood and the duct system must be calculated to select the proper exhaust fan. Isotope Bench Fume Hoods — Vertical Rising Sash 4'-0" KS-20S5448 Auxiliary Air 5'-0" 6'-0" KS-20S5460 KS-20S5472 End View Isotope fume hoods can be converted to Auxiliary Air Hoods by adding an Auxiliary Air Chamber. See page 7. Restricted By-pass (for VAV exhaust systems) General Purpose fume hoods may be converted to a Restricted By-pass model for use with VAV exhaust systems. See page 7. 5 Supreme Air Fume Hoods Perchloric Acid Bench Hood Specifications Designed primarily for use with perchloric acid. Features coved corner and seamless welded Type 316 stainless steel work top with intersecting rear and interior end panels for ease of cleaning and decontamination. Complete with a Type 316 stainless steel lining and baffle, with fixed center, upper, and lower exhaust slots. Furnished with a Type 304 stainless steel lower deflector vane; a counterbalanced, frameless sash of 1/4" laminated safety glass; a full length sash handle; and a louvered top front panel. A full length perforated spray pipe is located behind the top baffle to simplify periodic washdown procedures. Exterior fabricated of cold rolled steel. Finish is light neutral color. Type 316 stainless steel exhaust duct collar is 1115/16" O.D. Accessories Included: Two front loaded remote controlled service fittings (one cold water, one wash-down water), two 120 volt AC 20 amp GFI duplex receptacles, vaporproof light fixture(s) (bulbs not included) with 20 amp light switch, and a motor rated fan switch (thermal unit not provided). Devices are wired to junction boxes mounted at the top exterior of the hood. Optional Accessories: The right hand post is punched for an Air Alert 300 Alarm and is furnished with a cover plate. Alarm, fan, and base units must be ordered separately. Additional Parts Required for Complete Fume Hood Assembly Base Cabinets page 8 page 16 Fan/Blower Note: Only steel base cabinets are recommended for use under perchloric acid fume hoods. DIMENSIONS Overall Dimensions Sash Opening Work Top Clearance (sash up) HEIGHT 893/4" 28" * 37" 97" LENGTH 48" 40" 40" ... 60" 52" 52" ... DEPTH 72" 64" 64" ... 36" ... 251/2" ... *Sash opening height above airfoil. Add 1" to calculate sash opening area. Type 316 Stainless Steel Linings: Interior fume hood lining and baffle are 16-gauge, Type 316 stainless steel. The seamless welded 14-gauge, Type 316 work top is dished 1/2" to retain spillage and has an integrally welded trough sink at the rear. (Work tops are not available with vent holes for use with acid storage base cabinets). Overall Hood Length Sash Opening Sq. Ft. 4'-0"/48" 5'-0"/60" 6'-0"/72" 8.1 10.5 12.9 Total CFM and Static Pressure 80 100 120 FPM S.P. FPM S.P. FPM S.P. not recommened not recommened 980 0.35" not recommened not recommened 1260 0.45" not recommened not recommened 1550 0.60" Static pressures shown are for the pressure drop through the hoods only. The total pressure drop through the hood and the duct system must be calculated to select the proper exhaust fan. Perchloric Acid Bench Fume Hoods — Vertical Rising Sash 4'-0" KS-25L5448 Auxiliary Air 5'-0" 6'-0" KS-25L5460 KS-25L5472 End View Perchloric Acid fume hoods can be converted to Auxiliary Air Hoods by adding an Auxiliary Air Chamber. See page 7. Restricted By-pass (for VAV exhaust systems) General Purpose fume hoods may be converted to a Restricted By-pass model for use with VAV exhaust systems. See page 7. 6 Supreme Air Fume Hoods Auxiliary Air Chambers Specifications Auxiliary Air Chambers may be added to the top of any Supreme Air Fume Hood in this catalog to convert them to Auxiliary Air fume hoods. Adding the auxiliary air chamber makes it possible for the fume hood to operate on up to 70% auxiliary air, thus saving expensive conditioned room air from being exhausted. No modifications to the fume hood are required, and the chamber comes complete with all necessary parts to make the conversion, except fan and duct work. The chambers are fabricated of cold rolled steel. Finish is light neutral color. Bench and Walk-In Fume Hood Auxiliary Air Requirements (based on 70% of hood air requirements) Overall Hood Length 80 FPM 4'-0" / 48" 5'-0" / 60" 6'-0" / 72" 8'-0" / 96" 460 590 730 990 Total CFM and Static Pressure S.P. 100 FPM S.P. 120 FPM S.P. 0.15" 570 0.15" 740 0.15" 900 0.15" 1240 0.25" 690 0.25" 880 0.25" 1090 0.25" 1490 0.35" 0.30" 0.30" 0.30" Auxiliary Air Chambers for Bench and Walk-In Fume Hoods 4'-0" 5'-0" 6'-0" 8'-0" CF5-1348-03 CF5-1360-03 CF5-1372-03 CF5-1396-03 End View Restricted By-pass Fume Hoods Fume Hoods using a Variable Air Volume (VAV) exhaust system require a by-pass restrictor to obstruct the airflow through the upper by-pass. The By-pass Restrictor Kit include: a restricting panel, mounting angles, and all hardware required for mounting in the field. Contact your sales representative concerning special restriction requirements. Restrict By-pass Kit for VAV Exhaust Systems 4'-0" CF5-1348-03 5'-0" CF5-1360-03 6'-0" CF5-1372-03 8'-0" CF5-1396-03 7 Fume Hood Base Cabinets REDISHIP General Storage Fume Hood Base Cabinets Specifications Steel Fume Hood Base Cabinets are 353/4" high and 22" deep, lengths as shown below. They are available in two styles. Contour style features doors and drawer heads with a radiused full-width integral pull. Trademark style features doors and drawers with an aluminum bail-type pull. Both styles are furnished with removable backs and are finished in Light Neutral color. Contour Style Steel Cabinets CFG-2084-0F2 CFG-2085-0F2 CFG-2086-0F2 CFG-2088-0F2 CFG-2089-0F2 24"L 30"L 36"L 48"L 60"L Acid Storage Fume Hood Base Cabinets Specifications Acid Storage Fume Hood Base Cabinets are specifically designed for the storage of corrosive chemicals. They are available in either steel or wood. These cabinets are lined with a molded one piece linear low density polyethylene tub with coved corners and a 1" lip at the bottom front. The cabinet doors are lined with 1/8" sheet polyethylene and the doors are latched using a nylon roller catch. Each cabinet is furnished with a PVC vent pipe for venting to the fume hood above. (Requires a 2" hole in the hood worksurface). Vent Location: 30" Cabinet – 75/8" Right of Center 36" Cabinet – 5" Right of Center 48" Cabinet – 5" Right of Center Contour Style Steel Cabinets CFG-ACID-301 CFG-ACID-361 CFG-ACID-481 30"L 36"L 48"L Contour Style Vacuum Pump Storage Fume Hood Cabinets Specifications KSG35M3724L3 24"L Left Swing KSG35M372403 24"L Right Swing 8 Vacuum Pump Storage Fume Hood Cabinets are designed without a bottom to allow vacuum pumps and other equipment to be rolled in or out of the cabinets. The interior is lined with 1" thick neoprene foam for sound deadening and easy cleaning. Each cabinet is furnished with a 120 VAC, 20 amp, duplex receptacle mounted on the inside cabinet back and a pilot-lighted toggle switch mounted in the top front rail. (Wiring is not included). Cabinets are also furnished with a 2" diameter PVC vent pipe for venting or access to the hood above. (Requires a 2" hole in the hood worksurface to be bored at time of installation). The toespace rail is attached to the door to allow total access to the cabinet. Cabinet inside clearance at the floor is 161/2" frontto-back and 3" less than the overall cabinet length. Fume Hood Base Cabinets REDISHIP Solvent Storage Fume Hood Cabinets Specifications Solvent Storage Cabinets are specifically designed for the storage of flammable and combustible liquids. The cabinet is UL listed and meets UFC, OSHA and NFPA No. 30-1993 construction standards. It is all 18gauge steel, double panel construction with self-closing doors, synchronized so that both doors will always fully close. The right hand door is equipped with a three-point latching system that automatically engages the cabinet frame. Each door is equipped with a fusible-link hold-open feature that ensures the doors close should the temperature outside the cabinet exceed 165°F. A 2" deep liquid-tight pan covers the entire bottom to contain liquid leaks and spills. A full depth adjustable shelf, perforated to allow circulation within the cabinet, is also furnished. Two diametrically opposed vents with spark screens as well as a grounding screw are provided in the back of the cabinet. The cabinet is labeled: CAUTION FLAMMABLE – KEEP FIRE AWAY. Steel Solvent Storage Fume Hood Cabinets CFG-SOLV-301 CFG-SOLV-361 CFG-SOLV-481 30"L 36"L 48"L Vent outlets are 11/2" Male NPT 9 Fume Hood Service Fittings Specifications Standard Remote Control Fittings are for use on General Purpose fume hoods and may be used on either side of the hood. They include brass valve with replaceable seat, Nylon color-coded panel flange with angle serrated hose connector or gooseneck with sepia bronze finish, plastic color-coded four arm handle, and tank nipple, locknut, and washer. Standard fittings also include remote control rod assembly and black plastic angle flange. Front Load Remote Control Fittings are for use on Isotope hoods. They must be ordered for use on either the left or right side of the hood. Service Fitting Color Codes: Air . . . . . . . . . . . . . . . . . . . .Orange Cold Water . . . . . . . . . .Dark Green Distilled Water . . . . . . . . . . . .White Gas . . . . . . . . . . . . . . . . .Dark Blue They include brass valve with replaceable seat, Nylon color-coded Nitrogen . . . . . . . . . . . . . . . .Brown panel flange with angle serrated hose Vacuum . . . . . . . . . . . . . . . . .Yellow connector or gooseneck with sepia bronze finish, plastic color-coded four arm handle, and tank nipple, locknut, and washer. Standard Remote Control Fittings (for use on General Purpose Fume Hoods) Panel Flange with Angle Serrated Hose Connector VFT-0860-3A Air VFT-0860-3G Gas VFT-0860-3N Nitrogen VFT-0860-3V Vacuum VFT-0861-3W Cold Water VFT-0862-3D Distilled Water Cold Water Gooseneck with Vacuum Breaker VFT-0864-3WV 273/4" Long Handle 121/2" Long Handle Front Load Remote Control Fittings (for use on Isotope Fume Hoods) Nylon Panel Flange with Angle Serrated Hose Connector Nylon Panel Flange with Angle Serrated Hose Connector Left Hand Fittings VFT-0739-L-AIR VFT-0739-L-GAS VFT-0739-L-NIT VFT-0739-L-VAC VFT-0739-L-CW VFT-0739-L-FD Right Hand Fittings VFT-0739-R-AIR VFT-0739-R-GAS VFT-0739-R-NIT VFT-0739-R-VAC VFT-0739-R-CW VFT-0739-R-FD 10 Air Gas Nitrogen Vacuum Cold Water Distilled Water Air Gas Nitrogen Vacuum Cold Water Distilled Water Cold Water Gooseneck with Vacuum Breaker VFT-0740-L-VB Left Hand Fitting Fume Hood Work Tops & Accessories Kemresin Supreme Air Fume Hood Work Tops (color: Black) 4'-0" 5'-0" 6'-0" for VWR hood for VWR hood VF5-0204-A1 KS-05K5448 97005-992 97005-998 VF5-0205-A1 KS-05K5460 97005-994 97006-000 VF5-0206-A1 97005-996 8'-0" for VWR hood for VWR hood KS-05K5472 97006-002 VF5-0208-A1 KS-05K5496 for VWR hood for VWR hood VF5-0204-A8 KS-05K5448 VF5-0205-A8 KS-05K5460 VF5-0206-A8 for VWR hood for VWR hood KS-05K5472 VF5-0208-A8 KS-05K5496 with 2" dia. vent hole for use with 48" vented acid storage fume hood base cabinet. with 2" dia. vent hole for use with 30" vented acid storage fume hood base cabinet located on right side of hood. with 2" dia. vent hole for use with 36" vented acid storage fume hood base cabinet located on right side of hood. with 2" dia. vent hole for use with 48" vented acid storage fume hood base cabinet located on right side of hood. Cupsink Cutout Cover VFR-5405-CP Molded of black Kemresin. Designed to fill cupsink cutout in work top when a cupsink is not required. Included with all fume hood work tops shown above. Air Alert 300 Face Velocity Airflow Alarm VFX-0185-28 Consists of a thermistor sensor mounted through the end wall of the hood, and a control monitor that gives both a visual and audible alarm. The alarm monitors the fume hood face velocity and sounds an alarm when the airflow falls below safe levels. A glowing green light signals when conditions are again safe. The control monitor, which is mounted on the hood fascia, also contains a test/reset button that allows the hood user to verify alarm readiness. The Air Alert 300 operates on a 9 volt DC circuit and comes complete with an adapter that can be plugged into any 120 VAC receptacle. Air Alert 300 not recommended for use with Auxiliary Air Fume Hoods Air Alert 300 not for use with Supreme Air LV High Performance Fume Hoods 11 Fume Hood Wiring & Piping Specifications All Supreme Air Fume Hoods shown in this catalog are pre-wired at the factory. The light fixture, receptacles, and light switch are wired to a single junction box located at the top of the hood for a single point connection at the job site. An auxiliary receptacle is furnished on the top of the hood next to the junction box to provide power to the optional airflow alarm.The fan switch is wired to a seperate junction box on the top of the hood. All wiring uses flexible metallic conduit and is UL listed. All service fittings and plumbing ordered with the hood are shipped seperate for installation by the plumber (except on the Perchloric Acid fume hood). No service piping or drain lines are furnished. Typical Fume Hood with Plumbing & Wiring Connections Fan Junction Box Main Junction Box furnished and wired to fan switch furnished and wired to light, receptacles, and light switch Auxiliary Receptacle furnished and wired to main junction box Fan Switch furnished and wired to fan junction box Light Switch furnished and wired to main juction box GFI Duplex furnished and wired to main junction box (one each side) Service Fittings and Valves furnished seperately when ordered installed by others (typical for both sides of hood) Supply Lines with Shut-off Valves supplied and connected by others 12 Waste Line - Trap - Tailpiece supplied and connected by others Supreme Air Fume Hood Technical Data Bench Hood – Dimensional Information Vertical Section General Purpose Bench Hoods Rough-In for General Purpose Bench Hoods 36" 1 1/2 " 22" 20" 5 1/2" 9 1/2" EQ 2" 89 3/4 " 28" Sash Opening Pipe Space Below Work Top Plumbing Access (both sides) 1/2 Hood Length EQ 11" 97" Clearance – Sash Up 5" 54" 4" 4" 29 1/2 " 4" 4" 5" 25 1/2 " 84" 8" 1" 2 1/2 " 7" 35 3/4 " 36" 11 15/16 " O.D. Exhaust Collars 22" 96" – 120" – 144" 8" Supreme Air LV Fume Hood – Rough-In & Dimensional Information Rough-In for Supreme Air LV Bench Hoods Vertical Section Supreme Air LV Bench Hood 13 Supreme Air Fume Hood Technical Data Isotope Hood – Rough-In & Dimensional Information Rough-In for Isotope Bench Hood Vertical Section Isotope Bench Hood 36" 1 1/2 " 22" 20" 89 3/4 " 28" Sash Opening 97" Clearance – Sash Up 5" 54" 4" 4" 29 1/2 " 4" 4" 5" 25 1/2 " 84" 8" 2 1/2 " 35 3/4 " 22" 8" Perchloric Acid Hood – Rough-In & Dimensional Information Rough-In for Perchloric Acid Hood Vertical Section Perchloric Acid Bench Hood 36" 1" 4 3/4" 9 1/2" 1 1/2 " 7" 22" 20" 36" 89 3/4 " 28" Sash Opening 97" Clearance – Sash Up 5" 54" 16" 29 1/2 " 5" 25 1/2 " 84" 8" 2 1/2 " 35 3/4 " 22" 14 8" Supreme Air Fume Hood Technical Data Walk-In Hood – Dimensional Information Vertical Section General Purpose Walk-In Hoods Rough-In for General Purpose Walk-In Hoods 1 1/2 " 89 3/4 " 28" Upper Sash Opening 5" 60 3/4 " Total Sash Opening 103" Clearance – Sash Up 22" 20" 4" 4" 29 1/2 " 4" 4" 5" 25 1/2 " 84" 38 1/4 " 43 3/4 " 36" Auxiliary Air Chamber – Rough-In & Dimensional Information Rough-In for Auxiliary Air Chamber Vertical Section Auxiliary Air Chamber on Bench Hood 15 Fume Hood Exhaust Systems Determining Fume Hood Exhaust and Supply Requirements All fume hoods, regardless of type or use, require a fan/blower to exhaust the air from the hood to outside atmosphere. Typically mounted on the building roof, the fan/blower also requires a duct system to connect it to the hood, and a stack head to exhaust the contaminated air above the building’s fresh air intakes. In addition, if the fume hood uses an auxiliary air chamber, a second supply fan/blower is also required along with a seperate duct system. Your VWR Furniture Specialist can provide more information and help with the exhaust/supply system design. Because of the many factors involved with designing a fume hood exhaust/supply system, it is recommended that you contact an HVAC professional as well, who is experienced with laboratory fume hood exhaust requirements and is knowledgeable of local mechanical and electrical building codes. For more information contact you VWR Furniture Specialist — 1-888-624-2432 16 Supreme Air Fume Hood Construction Supreme Air Fume Hood Technical Data The Supreme Air Fume Hood design is based on rigid frame construction that assures solid installation and low vibration and sound levels. Access panels are easily removable to access service lines and fittings. Radius corner posts and airfoils, plus fixed interior baffle settings assure a high level of comfort, safety and efficiency. Supreme Air Fume Hood Wiring Diagram With a variety of models available and selected option packages, this new generation of fume hoods can be tailored to the application needs of your modern laboratory. Aesthetically pleasing curved airfoils, contemporary controls and devices, and an eye-pleasing light neutral color, make this hard-working laboratory safety device an attractive part of the total laboratory environment. Excellent interior lighting • Single tube, low profile,T5 fluorescent light fixture • Tube replacement from outside of hood KMER modified epoxy resin liner • 1/4" thick, solid, light neutral colored liner • Class A fire rating • Low profile, self-gasketing, interior access panel — removable without tools • Stainless steel liner for Isotope and Perchloric Acid Hoods Customizable accessory offerings • A full array of service fittings • Monitoring safety alarm available Prewired light and receptacles • UL listed per UL 3101-1 1993 Low profile PVC sash tracks • Smooth sash operation • Reduced air turbulence • Seals the interior side panel Easy-to-operate full vision sash with: • Full length painted aluminum handle for neat, clean appearance and streamlined air features • Exclusive sash leveling and alignment features Independent frame construction • Rigid structural frame • Allows liner panel replacement • Stainless steel fasteners concealed with corrosionresistant caps Narrow-radiused corner posts • Enhances aerodynamic air flow • 4" width creates more interior work space Radiused air foil • Streamline air flow — low turbulence • Heavy gauge stainless steel for durability Exclusive Kemresin work tops • Dished black epoxy resin worksurface available • Integral stainless steel worksurface in Isotope and Perchloric Acid hoods Specialized base cabinets • UL listed solvent storage cabinets • One-piece polyethylene lined acid storage cabinets • Vacuum pump storage cabinets • Cabinets available in both wood and steel SQUARE D THERMAL UNIT SIZING The fan switch requires the installation of a Square D Thermal unit to function. The thermal unit is not supplied with the switch as it must be selected based on the full load amperage of the fan motor. Motor Full-load Current Amperes 0.41 - 0.44 0.45 - 0.49 0.50 - 0.53 0.54 - 0.58 0.59 - 0.65 0.66 - 0.71 0.72 - 0.78 0.79 - 0.85 0.86 - 0.96 0.97 - 1.04 1.05 - 1.16 Thermal Unit No. A .49 A .54 A .59 A .65 A .71 A .78 A .86 A .97 A 1.02 A 1.16 A 1.25 Motor Full-load Current Amperes 1.17 - 1.29 1.30 - 1.37 1.38 - 1.47 1.48 - 1.56 1.57 - 1.65 1.66 - 1.79 1.80 - 1.95 1.96 - 2.15 2.16 - 2.38 2.39 - 2.75 2.76 - 2.84 Thermal Unit No. A 1.39 A 1.54 A 1.63 A 1.75 A 1.86 A 1.99 A 2.15 A 2.31 A 2.57 A 2.81 A 3.61 Motor Full-load Current Amperes 2.85 - 3.06 3.07 - 3.45 3.46 - 3.70 3.71 - 4.07 4.08 - 4.32 4.33 - 4.90 4.91 - 5.35 5.36 - 5.85 5.86 - 6.41 6.42 - 6.79 6.80 - 7.57 Thermal Unit No. A 3.95 A 4.32 A 4.79 A 5.30 A 5.78 A 6.20 A 6.99 A 7.65 A 8.38 A 9.25 A 9.85 Motor Full-load Current Amperes 7.58 - 8.15 8.16 - 8.98 8.99 - 9.67 9.68 - 9.95 9.96 - 10.8 10.9 - 12.1 12.2 - 13.1 13.2 - 13.9 14.0 - 15.0 15.1 - 16.0 Thermal Unit No. A 11.0 A 11.9 A 13.2 A 14.1 A 14.8 A 16.2 A 17.9 A 19.8 A 21.3 A 25.2 VWR Furniture Complete Dedicated Furniture Solutions Factory trained VWR Furniture Specialists work in coordination with VWR sales representatives to help you select the most functional and costeffective solutions for your lab. They will closely monitor inventory of top-quality furniture and components, as well as provide complete project supervision from proposal through installation. • VWR Furniture Project Estimators help you identify your lab furniture requirements and provide a comprehensive quote of your project’s cost • VWR Furniture Design Specialists create lab plans to suit your specifications using the latest computer aided design (CAD) software • VWR Project Coordinators manage every detail including ordering, shipping, and final installation • VWR Furniture Installers have extensive experience and knowledge of our product line, insuring a fast, trouble-free finish to your project To learn more about VWR Furniture Products, Services, and Customer Support visit vwr.com today! 0811 (10M) Lit. No. 11030 KEWAUNEE Supreme Air Series Fume Hoods