Conductivity/Resistivity Meter
Transcription
Conductivity/Resistivity Meter
■Sensor (Unit: mm) Our worldwide service network ensures speedy support, when and where you need it. ●2-electrode sanitary conductivity sensor ■Flow-through sensor FS-01 Series ■Connector cable CK- ■M ■Insertion type sensor ESH-01-C-S-SN-1.5S Maintenance space 50 or more Maintenance space 50 or more Cable length: L (ø6.5) 50 A B C øD A 2.5S (140) Model 82.5 (99.5) (103) (108.5) (114) (126.5) 55 85 110 65 75 Cable length +5% CK-Y10M 10 m 0 CK-Y20M 20 m +5% 0 CK-Y30M 30 m +5% 0 Japan China U.K. HORIBA INSTRUMENTS LIMITED HORIBA TRADING (SHANGHAI) CO., Ltd. HORIBA, Ltd. HORIBA Advanced Techno Co., Ltd. HORIBA STEC Co., Ltd. HORIBA TECHNO SERVICE Co., Ltd. Shanghai Office Beijing Office ø17 (ø50.5) ●4-electrode sanitary conductivity sensor 10m +5% 0 New Hampshire Office Santa Clara Office HORIBA Technology Center 10m Austin Office +5% 0 (105) HORIBA STEC Co., Ltd., Aso Factory 35 Depending on the coupling aperture of the sanitary ferrule Aperture 1.5S ø29 øB 2.0S 2.5S 3.0S 4.0S 4.5S øA 104 114 138 159 180 188 B (80.5) (86) (98) (109) (119.5) (123.5) 40 øA 73 (B) ) ( øA Portland Office (ø10) Maintenance space 100 or more Maintenance space 100 or more Clamp-on gasket (outside the scope of Horiba delivery) ■Insertion type sensor FES-210/220-L Series Cable-attached type (ø10) ■Flow-through sensor FES-310-L Series Cable-attached type Aperture 1.5S 2.0S øA 38.1 50.8 øB 50.5 64 (130) Germany France ■Flow-through sensor FES-310-C Series Connector type ■Connector cable SK- ■M HORIBA FRANCE SARL ■Insertion type sensor FES-210/220-C Series Connector type HORIBA EUROPE GmbH Singapore Taiwan HORIBA INSTRUMENTS PTE. Ltd. HORIBA, Ltd. TAIWAN Representative Office Korea HORIBA KOREA Ltd. U.S.A. HORIBA/STEC INCORPORATED Attach the SK series connector cable. Attach the SK series connector cable. 50 (ø10) Depending on the coupling aperture of the sanitary ferrule øA (91) 78 (B) ) ( øA Maintenance space 100 or more Maintenance space 100 or more Cable length: L Clamp-on gasket (outside the scope of Horiba delivery) Model 35 ø21 Cable length SK-Y10M ø29 øB +5% 10 m 0 +5% 0 SK-Y20M 20 m SK-Y30M 30 m +5% 0 40 (130) 2.5S 3.0S 4.0S 4.5S 104 114 138 159 180 188 B (80.5) (86) (98) (109) (119.5) (123.5) Maintenance space 100 or more ■Socket insertion type FES-240-L Cable-attached type (ø10) 10m +5% 0 FES-240-C Connector type ■VARIVENT® valve type FES-230-L Cable-attached type 10m (ø10) Attach the SK series connector cable. ø23.5 64 Please read the operation manual before using this product to assure safe and proper handling of the product. ● The contents of this catalog are subject to change without prior notice, and without any subsequent liability to this company. ● The color of the actual products may differ from the color pictured in this catalog due to printing limitations. ● It is strictly forbidden to copy the content of this catalog in part or in full. http://www.horiba-adt.jp/index_e.htm Head Office 31 Miyanonishicho, Kisshoin Minami-ku, Kyoto, Japan 601-8306 Phone: (81)75-321-7184 Fax: (81)75-321-7291 Attach the SK series connector cable. Tokyo Sales Office Arule-Bldg, Higashikanda. 4th Fl, 1-7-8 Higashi-Kanda Chiyoda-ku, Tokyo, Japan 101-0031 Phone: (81)3-3851-3150 Fax: (81)3-3851-3140 Nagoya Sales Office Sumitomoseimei Chigusa 2nd Bldg. 6th Fl, Aoi 3-15-31, Higashi-ku, Nagoya, Japan 461-0004 Phone: (81)52-937-0812 Fax: (81)52-937-0675 (ø84) (91) 78 32 (17) Socket (outside the scope of Horiba delivery) 50.5 ø38.1 (105) 78 32 (17) ø34.2 50.8 øB ø38.1 Keep at least 12 mm distance from the piping wall. ø23.5 Socket (outside the scope of Horiba delivery) 16 16 (106) 73.5 43.5 ø34.2 (86) 73.5 43.5 ø44.2 ø41.8 38.1 +5% 0 (ø84) ø44.2 ø41.8 2.0S øA FES-230-C Connector type ø29 Tuhenhagen DN40/50 plug Keep at least 12 mm distance from the piping wall. 2.0S øA Maintenance space 100 or more Aperture 1.5S Aperture 1.5S Service Stations ●Kyoto: (81)75-321-7972 ●Tokyo: (81)3-3851-3150 ●Nagoya: (81)52-937-0812 ø29 Bulletin:HAE-S0141C Tuhenhagen DN40/50 plug 13 Industrial Conductivity/Resistivity Meter Sanitary coupling ferrule 1.5S 85 B øD 1.0S 1.5S 2.0S (120) (120) (120) (120) 55.5 59 70 64.5 131 (175) C ø21 Aperture 15A Conductivity/Resistivity Meter Selection Guide & External Dimensions Attach the CK series connector cable. Attach the CK series connector cable. Clamp-on packing (outside the scope of Horiba delivery) Industrial 11 Printed in Japan 0902SK13 Industrial Resistivity Measurement principle Conductivity (SI unit) Resistivity The industrialtechnology and Conductivity Meter and Resistivity Meter Lineups 0.01 µS/cm 0.0548 (1 µS/m) 100 MΩ·cm 2-electrode conductivity 0.1 µS/cm 1 µS/cm 10 µS/cm (10 µS/m) (100 µS/m) (1000 µS/m) 1 MΩ·cm 10 MΩ·cm 18.24 Ultra pure water Pure water 100 KΩ·cm Distilled water Rain water Sample examples Water for Injection Resistivity y meter Conductivity meter (low concentration type) ■ 2-channel resistivity meter Pure water Ultra pure water Sterilized purified water, purified water HE-960RW ■ Resistivity meter HE-480R P4 ■ Conductivity meter (low concentration type) ■ Conductivity meter CE-200C P4 HE-480C P6 P6 (Rain-proof type) Industrial water Distilling plants Conductivity sensor ESH-001 Resistivity sensor ERF-001 Series Conductivity sensor ESH-01 Measurement range: 0-20 µS/cm Measurement range: 0-100.0 MΩ·cm Measurement range: 0-200 µS/cm * When used in conjunction with the CE-200C, measurement ranges expand to 10 µS/cm ■ Sanitary conductivity meter (low concentration type) HE-960CW Pharmaceutical processes P7 Food and beverage processes Flow-through sensor FS-01 Series Measurement range: 0-2000 µS/cm ■ Carbon sensor conductivity meter ■ Carbon sensor resistivity meter HE-960RW-GC Semiconductor cleaning processes P5 P5 Carbon sensor ERF-01-L-GC2 Measurement range: 0-100.0 MΩ·cm 2 HE-480C-GC HE-960R-GC P7 Carbon sensor ESH-01-L-GC5 Measurement range: 0-200 µS/cm Note: Measurement range listed in this document grade conductivity meters and resistivity meters made by Horiba Advanced Techno are highly reliable products that pledge the high accuracy and high stability of creative sensing a wealth of experience in diverse fields. Horiba Advanced Techno meets user needs with rich lineups for each and every type of application. 4-electrode conductivity 100 µS/cm 1000 µS/cm 10 mS/cm 100 mS/cm (10 mS/m) (100 mS/m) (1000 mS/m) (10 S/m) 10 KΩ·cm 1 KΩ·cm 100 Ω·cm 10 Ω·cm Tap water Boiler water Salt water solution Seawater Beer, juice and sports drinks Mineral water 1000 mS/cm (100 S/m) 1 Ω·cm Inorganic acids, strong electrolytes CIP: Cleaning-in-Place for chemicals Conductivity y meter (high ( g concentration type) yp ) ■ 2-channel conductivity meter HE-960CW ■ Conductivity meter ■ Conductivity meter (high concentration type) ■ Conductivity meter (wide range type) CEH-200 P7 HE-480H P8 HE-960HS P8 For details regarding this product, please contact us directly. (Rain-proof type) 4-electrode conductivity sensor FES-125F FES-126F Conductivity sensor ESH-1 Measurement range: 0-2000 µS/cm (ESH-001), 100 µS/cm (ESH-01) and 1000 µS/cm (ESH-1). Measurement range: 0-500 mS/cm * When used in conjunction with the CEH-200, measurement range expands to 20 mS/cm. ■ Sanitary conductivity meter (wide range type) HE-960HI P9 Insertion type sensor ESH-01-C-S-SN-1.5S Measurement range: 0-200 µS/cm (low concentration type) Flow-through sensor FES-300 Series Insertion type sensor FES-200 Series Measurement range: 0-500 mS/cm ■ Carbon sensor conductivity meter (wide range type) HE-960HC P9 Carbon sensor ESH-1-L-GC9 Measurement range: 0-2000 µS/cm Flow type carbon sensor FES-510 Series Measurement range: 0-1000 mS/cm is the maximum measurement possible and may vary depending on the combination used, environment conditions, and setting. 3 Resistivity Meter Resistivity meters 2-channel resistivity meter Resistivity meter HE-960RW HE-480R Panel mount DIN96 2 ch ● High-quality resistivity meter ● 2-channel simultaneous measurement ● Employs highly accurate, high-stability temperature measurement circuits ● Built-in RS-485 communications output ● Measures ultra pure water at a high degree of accuracy ● Implements advanced temperature compensation ● Allows for setting of the reference temperature to any value HE-960RW Model Panel mount SLIM48 1 ch HE-480R Model Measurement method Electrode type (2-electrode method) Measurement method Electrode type (2-electrode method) Sensor input Sensor input 2-channel (cell constant: 0.01/cm) Temperature sensor Resistance thermometer: 1000 Ω/0°C Resistivity: 0 to 2.00, 0 to 20.00 MΩ·cm Measurement Resistivity: 0 to 0.200, 0 to 2.00, 0 to 20.00 MΩ·cm Measurement 0 to 20.0, 0 to 200.0 kΩ·m range 1-channel (cell constant: 0.01/cm) Temperature sensor Resistance thermometer: 1000 Ω/0°C 0 to 2.00, 0 to 20.0, 0 to 200.0 kΩ·m range (Without temperature compensation, resistivity can be measured in 100.0 MΩ·cm and 1000 kΩ·m ranges.) (Without temperature compensation, resistivity can be measured in 100.0 MΩ·cm and 1000 kΩ·m ranges.) Temperature: 0 to 100°C (The number of decimals displayed can be selected between none, 1, and 2.) Temperature: 0 to 100°C (The number of decimals displayed can be selected between none, 1, and 2.) Reproducibility ±0.1% FS (equivalent input) Reproducibility ±0.5% FS (equivalent input) Linearity ±0.5% FS (equivalent input) Linearity ±0.5% FS (equivalent input) Transmission output No. of outputs: 2; 4 to 20 mA DC/0 to 20 mA DC; I/O insulation type; maximum load resistance 900 Ω Transmission No. of outputs: 1; 4 to 20 mA DC; I/O insulation type; maximum load resistance 900 Ω Contact output No. of outputs: 4 (R1, R2, R3, and R4) output Contact type: Relay contacts R1 to R3: SPST (1a); R4: SPDT (1c) Contact output No. of outputs: 2 (R1 and R2) Contact rating: 240 V AC 3 A, 30 V DC 3 A (resistance load) Contact type: Relay contact SPDT (1c) Contact function: Select between upper/lower limit operation (ON/OFF control), alarm, and Contact rating: 240 V AC 3 A, 30 V DC 3 A (resistance load) Contact function: Select between upper/lower limit operation (ON/OFF control), alarm, and maintenance. (R1 and R2, and R3 and R4 are for common use, respectively.) maintenance. Communication function RS-485 I/O Calibration function Resistivity: Based on the specified compensation coefficient for the cell constant (parameter input) Calibration Resistivity: Based on the specified compensation coefficient for the cell constant (parameter input) Temperature: Calibrated by comparing with the reference thermometer function Temperature: Calibrated by comparing with the reference thermometer Temperature Temperature compensation for impurities in ultra-pure water (Temperature characteristics of impurities are user-selectable.) Temperature Based on the temperature characteristics of ultra-pure water (reference temperature: 25°C) compensation Based on the temperature characteristics of NaCl (reference temperature: 5 to 95°C) compensation Based on the reference temperature and temperature coefficient user-defined (reference Based on the user-defined temperature coefficient (reference temperature: 5 to 95°C; temperature coefficient: ±5%/°C) temperature: 5 to 95°C; temperature coefficient: ±5%/°C) Power requirements 100 to 240 V AC ±10%, maximum 15 VA Power requirements 100 to 240 V AC ±10%, maximum 10 VA Conforming standards CE marking, FCC regulations Conforming standards CE marking, FCC regulations Compatible sensors ERF-001 series resistivity sensor (cell constant: 0.01/cm) Compatible sensors ERF-001 series resistivity sensor (cell constant: 0.01/cm) For ultra-pure water Resistivity sensor Responds to minute changes in the measurement water temperature Threaded type Model ERF-001 Series Cell constant Wetted material ERF-001 Approx. 0.01/cm Electrode Titanium Body PVDF Packing Pressure of fluid being measured FKM 0 to 0.5 MPa Temperature of fluid being measured ERF-001-L-T ERF-001-C-T (Cable-attached type) (Connector type) 0 to 80ºC Installation Threaded type; Thread diameter: R (PT) 3/4 Cable length Cable-attached type: 10 m, Y terminal (standard); limit cable extensions to a max. 50 m Connector type: 10 m (CK-10M), 20 m (CK-20M), 30 m (CK-30M) Holder to be combined Flow type holder EFA-30, EFA-30P, EFA-30S Compatible converter HE-480R, HE-960RW For ordering, refer to the model code chart on page 14. ■ Accessories Connector cable CK-10M/20M/30M Flow type holder EFA-30 Series Model EFA-30 EFA-30P Liquid end materials PVC PVDF SUS316 Liquid pressure range 0 to 0.1 MPa 0 to 0.1 MPa 0 to 0.5 MPa 0 to 100ºC 0 to 100ºC Liquid temperature range Liquid flow rate This cable is for connecting a connector type sensor to the indication converter. EFA-30 EFA-30P EFA-30S (PVC) (PVDF) (SUS-316) Connected pipe diameter 0 to 50ºC EFA-30S 0 to 10 L/min Inlet: Rc (PT) 1/2, Outlet: Rc (PT) 1/2 For ordering, refer to the model code chart on page 15. 4 Carbon sensor resistivity meters 2-channel resistivity meter Carbon sensor resistivity meter HE-960RW-GC 2 ch For semiconductor wet cleaning Panel mount DIN96 ● Carbon sensor compatible ● High speed response ● Allows for setting of the reference temperature to any value ● 24 V DC power supply RoHS RoHS COMPLIANT COMPLIANT HE-960RW-GC Measurement method Electrode type (2-electrode method) 2-channel (cell constant: 0.1/cm) Temperature sensor Resistance thermometer: 1000 Ω/0°C Resistivity: 0 to 2.00, 0 to 20.00 MΩ·cm Resistivity: 0 to 0.200, 0 to 2.00, 0 to 20.00 MΩ·cm Measurement 0 to 20.0, 0 to 200.0 kΩ·m range 1-channel (cell constant: 0.1/cm) Sensor input Temperature sensor Resistance thermometer: 1000 Ω/0°C Measurement HE-960R-GC Model Measurement method Electrode type (2-electrode method) Sensor input For semiconductor wet cleaning Panel mount DIN96 1 ch ● Carbon sensor compatible ● 2-channel simultaneous measurement ● High speed response ● Built-in array of temperature compensation functions ● 24 V DC power supply Model HE-960R-GC 0 to 2.00, 0 to 20.0, 0 to 200.0 kΩ·m range (Without temperature compensation, resistivity can be measured in 100.0 MΩ·cm and 1000 kΩ·m ranges.) (Without temperature compensation, resistivity can be measured in 100.0 MΩ·cm and 1000 kΩ·m ranges.) Temperature: 0 to 100°C (The number of decimals displayed can be selected between none, 1, and 2.) Temperature: 0 to 100°C (The number of decimals displayed can be selected between none, 1, and 2.) Reproducibility ±0.5% FS (equivalent input) Reproducibility ±0.5% FS (equivalent input) Linearity ±0.5% FS (equivalent input) Linearity ±0.5% FS (equivalent input) Transmission output No. of outputs: 2; 4 to 20 mA DC/0 to 20 mA DC; I/O insulation type; maximum load resistance 900 Ω Transmission No. of outputs: 1; 4 to 20 mA DC; I/O insulation type; maximum load resistance 900 Ω Contact output No. of outputs: 4 (R1, R2, R3, and R4) output Contact type: Relay contacts R1 to R3: SPST (1a); R4: SPDT (1c) Contact output No. of outputs: 2 (R1 and R2) Contact rating: 240 V AC 3 A, 30 V DC 3 A (resistance load) Contact type: Relay contact SPDT (1c) Contact function: Select between upper/lower limit operation (ON/OFF control), alarm, and Contact rating: 240 V AC 3 A, 30 V DC 3 A (resistance load) maintenance. (R1 and R2, and R3 and R4 are for common use, respectively.) Contact function: Select between upper/lower limit operation (ON/OFF control), alarm, and maintenance. Communication function RS-485 I/O Calibration function Resistivity: Based on the specified compensation coefficient for the cell constant (parameter input) Calibration Resistivity: Based on the specified compensation coefficient for the cell constant (parameter input) Temperature: Calibrated by comparing with the reference thermometer function Temperature: Calibrated by comparing with the reference thermometer Temperature Temperature compensation for impurities in ultra-pure water (Temperature characteristics of impurities are user-selectable.) Temperature Based on the temperature characteristics of ultra-pure water (reference temperature: 25°C) compensation Based on the temperature characteristics of NaCl (reference temperature: 5 to 95°C) compensation Based on the reference temperature and temperature coefficient user-defined (reference Based on the user-defined temperature coefficient (reference temperature: 5 to 95°C; temperature coefficient: ±5%/°C) temperature: 5 to 95°C; temperature coefficient: ±5%/°C) Power requirements 24 V DC, maximum 10 W Power requirements 24 V DC, maximum 5 W Conforming standards CE marking, FCC regulations Conforming standards CE marking, FCC regulations Compatible sensors ERF-01 carbon resistivity sensor (cell constant: 0.1/cm) Compatible sensors ERF-01 carbon resistivity sensor (cell constant: 0.1/cm) World’s first chemical-resistant glass carbon sensor! ●Excellent chemical resistance Leads are made of 100% carbon and therefore exhibit excellent chemical resistance against all types of cleaning fluids such as hydrogen fluoride and hydrogen peroxide. For semiconductor wet cleaning Carbon resistivity sensor Applicable to single-bach cleaning systems Glass carbon sensor offers superior resistance to chemicals Threaded type Model ERF-01-L-GC2 ERF-01-L-GC2 Cell constant Approx. 0.1/cm Wetted material ●Metallic contamination-free Electrode Glass carbon Body PFA Kalrez® Packing Pressure of fluid being measured There is no need to worry about the metallic contamination that was unavoidable with metal leads of the past. The carbon surface has been specially treated to minimize particle runoff. 0 to 0.05 MPa Temperature of fluid being measured Installation 0 to 80ºC Threaded type; Thread diameter: R (PT) 3/4 Cable length ●High speed response ERF-01-L-GC2 Cable-attached type Due to the special treatment of the carbon surface, response from chemicals and ultrapure water is the same as earlier models. 10 m, Y terminal (standard) Holder to be combined Flow type holder EFA-30P, EFA-30F Compatible converter HE-960R-GC, HE-960RW-GC For ordering, refer to the model code chart on page 14. ■ Accessories Flow type holder EFA-30 Series Model EFA-30P Liquid end materials Liquid pressure range Liquid temperature range Liquid flow rate EFA-30P (PVDF) Connected pipe diameter EFA-30F PVDF PFA 0 to 0.1 MPa 0 to 100ºC 0 to 10 L/min Inlet: Rc (PT) 1/2, Outlet: Rc (PT) 1/2 *For flow type holder, use EFA-30P(PVDF) or EFA-30F(PFA) respectively. For ordering, refer to the model code chart on page 15. 5 Conductivity Meter (low concentration type) Conductivity meters (2-electrode type) Conductivity meter (rain-proof type) Conductivity meter (low concentration type) CE-200C HE-480C 1 ch Low concentration type Rain-proof type Low concentration type Panel mount SLIM48 1 ch ● Perfect for continuous measurement of ultra-pure water. ● Automatic determination of sensor integrity ● Built-in temperature characteristics for each type of solution ● Large custom LCD ● Simultaneous display of measured values and parameter settings ● Ideal for continuous measurement of pure water and boiler water ● High precision temperature compensation ● Automatic determination of sensor integrity ● Supports a variety of temperature compensation Model Model CE-200C HE-480C Measurement method Electrode type (2-electrode method) Measurement method Electrode type (2-electrode method) Sensor input Sensor input 1-channel (cell constant: 0.01/cm, 0.1/cm, 1.0/cm) Temperature sensor Resistance thermometer: 1000 Ω/0°C 1-channel (cell constant: 0.01/cm, 0.1/cm, 1.0/cm) Temperature sensor Resistance thermometer: 1000 Ω/0°C Measurement Cell constant (/cm) 0.01 0.1 1.0 range Conductivity (µS/cm) 1.00 10.0 100.0 2.00 20.0 200 5.00 50.0 500 10.00 100.0 1000 Measurement Cell constant (/cm) range Conductivity 0.01 0.1 1.0 (µS/cm) 2.000/20.00 20.00/200.0 200.0/2000 (mS/m) 0.2000/2.000 2.000/20.00 20.00/200.0 2.00/20.0 20.0/200 200/2000 TDS conversion (mg/L) Temperature: 0 to 100°C (The number of decimals displayed can be selected between none, 1, and 2.) Temperature: 0 to 100°C (measurement only) Reproducibility Reproducibility ±0.5% FS Transmission output No. of outputs: 1; 4 to 20 mA DC; I/O insulation type; maximum load resistance 900 Ω Transmission No. of outputs: 1; 4 to 20 mA DC; I/O insulation type; (Transmission output of temperature is Contact output output not attached.) Maximum load resistance: 500 Ω Contact type: Relay contact SPDT (1c) Contact output No. of outputs: 2 Contact rating: 240 V AC 3 A, 30 V DC 3 A (resistance load) Contact type: Relay contact SPDT (1c) Contact function: Select between upper/lower limit operation (ON/OFF control), USP ±0.5% FS (TDS: ±1.5% FS) No. of outputs: 2 (R1 and R2) Contact rating: 250 V AC 3 A (resistance load) determination, error alarm, and maintenance. Contact function: Upper/lower limit operation (ON/OFF control) Calibration Conductivity: Based on the specified compensation coefficient for the cell constant (parameter input) Calibration Conductivity: Depends upon the cell constant setting function Temperature: Calibrated by comparing with the reference thermometer function Temperature: One-point calibration at a known temperature Temperature Ultra-pure water (limited to 1.00 µS/cm at a cell constant of 0.01) Temperature Based on the temperature characteristics of ultra-pure water (reference temperature: 25°C) compensation NaCl (when the cell constant is 0.01, 0.1, or 1.0) 0 to ±5%/°C (custom setting possible) compensation Based on the reference temperature and temperature coefficient user-defined (reference temperature: 5 to 95°C; temperature coefficient: ±5%/°C) TDS: Conversion using user-set coefficient (0.30 to 1.00) Temperature characteristics of NaCl Power requirements 100 to 115 V AC or 200 to 240 V AC (as ordered), 7 VA (max.) Structure Outdoor installation: JIS CO920; Protection level: 3 (rain-proof) Power requirements 100 to 240 V AC ±10%, maximum 10 VA Installation method: 50 A pole or wall attachment Conforming standards CE marking, FCC regulations Compatible sensors ESH series conductivity sensor (cell constant: 0.01/cm, 0.1/cm, 1.0/cm) General-purpose Compatible sensors ESH and FS series conductivity sensor (cell constant: 0.01/cm, 0.1/cm, 1.0/cm) 2-electrode method conductivity sensor Model Threaded type Cell constant ESH-001·01·1 Series Wetted material ESH-001 ESH-01 ESH-1 Approx. 0.01/cm Approx. 0.1/cm Approx. 1.0/cm Electrode SUS-316 or Titanium Body PVDF Packing Pressure of fluid being measured FKM 0 to 0.5 MPa Temperature of fluid being measured Flange mounting type ESH-01 ESH-01 ESH-01 (Cable-attached type) (Connector type) (Connector type) 0 to 100ºC Installation Threaded type; Thread diameter: R (PT) 3/4 Cable length Cable-attached type: 10 m, Y terminal (standard); limit cable extensions to a max. 100 m Connector type: 10 m (CK-10M), 20 m (CK-20M), 30 m (CK-30M) Holder to be combined Flow type holder EFA-30, EFA-30P, EFA-30S Compatible converter CE-200C, HE-480C, HE-960CW For ordering, refer to the model code chart on page 15. ■ Accessories Relay box CT-20EC Sensor extension cable C-5C Connector cable CK-10M/20M/30M Flow type holder EFA-30 Series Model Liquid end materials Liquid pressure range Liquid temperature range Liquid flow rate Used for connecting the converter and the relay box. This cable is for connecting a connector type sensor to the indication converter. EFA-30 EFA-30S (PVC) (SUS-316) Connected pipe diameter EFA-30 EFA-30P EFA-30S PVC PVDF SUS316 0 to 0.1 MPa 0 to 0.1 MPa 0 to 0.5 MPa 0 to 50ºC 0 to 100ºC 0 to 100ºC 0 to 10 L/min Inlet: Rc (PT) 1/2, Outlet: Rc (PT) 1/2 For ordering, refer to the model code chart on page 15. 6 Sanitary conductivity (2-electrode type) Carbon sensor conductivity meter (2-electrode type) 2-channel conductivity meter (low concentration type) Carbon sensor conductivity meter (low concentration type) HE-960CW HE-480C-GC Panel mount DIN96 2 ch Low concentration type Panel mount SLIM48 1 ch ● High grade type suited for monitoring of medical water quality ● 2-channel simultaenous measurement and simultaneous output ● Built-in USP<645> water quality evaluation function ● Built-in RS-485 communication output For semiconductor wet cleaning Low concentration type ● Carbon sensor compatible ● Wide measurement range ● Simultaneous display of measured values and parameter settings ● Built-in array of temperature compensation functions RoHS COMPLIANT HE-960CW Model Model Measurement method Electrode type (2-electrode method) 2-channel (cell constant: 0.01/cm, 0.1/cm, 1.0/cm) Sensor input Sensor input Temperature sensor Resistance thermometer: 1000 Ω/0°C Measurement Cell constant (/cm) range Conductivity HE-480C-GC Measurement method Electrode type (2-electrode method) 1-channel (cell constant: 0.01/cm, 0.1/cm, 1.0/cm) Temperature sensor Resistance thermometer: 1000 Ω/0°C 0.01 0.1 1.0 (µS/cm) 2.000/20.00 2.000/20.00/200.0/2000* 200.0/2000 (mS/m) 0.2000/2.000 0.2000/2.000/20.00/200.0* 20.00/200.0 Measurement Cell constant (/cm) range Conductivity *Only applicable for FS-01 series sanitary sensors. 1.0 20.00/200.0 200.0/2000 (mS/m) 0.2000/2.000 2.000/20.00 20.00/200.0 2.00/20.0 20.0/200 200/2000 When used in conjunction with the ESH-1-L-GC9, if the sensor is operated with temperature compensation unset or at a ±0.5% FS (TDS: ±1.5% FS) temperature of 30°C or below, measurement is possible over a range of up to a maximum of 9999 µS/cm and 999.9 mS/m. Transmission output No. of outputs: 4; 4 to 20 mA DC, 0 to 20 mA DC; I/O insulation type; maximum load resistance 900 Ω Contact output 0.1 2.000/20.00 TDS conversion (mg/L) Temperature: 0 to 100°C (1- or 2-digit selectable, whole numbers only) Reproducibility 0.01 (µS/cm) Reproducibility ±0.5% FS (TDS: ±1.5% FS) No. of outputs: 4 (R1, R2, R3, and R4) Transmission output No. of outputs: 1; 4 to 20 mA DC; I/O insulation type; maximum load resistance 900 Ω Contact type: Relay contacts R1 to R3: SPST (1a); R4: SPDT (1c) Contact output No. of outputs: 2 (R1 and R2) Contact rating: 240 V AC 3 A, 30 V DC 3 A (resistance load) Contact type: Relay contact SPST (1a) Contact function: Select between upper/lower limit operation (ON/OFF control), UPS determination, error Contact rating: 240 V AC 3 A, 30 V DC 3 A (resistance load) alarm, and maintenance. (R1 and R2, and R3 and R4 are for common use, respectively.) Communication function RS-485 I/O Contact function: Select between upper/lower limit operation (ON/OFF control), USP determination, error alarm, and maintenance. Calibration Conductivity: Based on the specified compensation coefficient for the cell constant (parameter input) function Temperature: Calibrated by comparing with the reference thermometer Calibration Conductivity: Based on the specified compensation coefficient for the cell constant (parameter input) function Temperature: Calibrated by comparing with the reference thermometer Temperature Based on the temperature characteristics of NaCl (reference temperature: 5 to 95°C) Temperature Based on the temperature characteristics of ultra-pure water (reference temperature: 25°C) compensation Based on the reference temperature and temperature coefficient user-defined (reference temperature: 5 to 95°C; temperature coefficient: ±5%/°C) compensation Based on the reference temperature and temperature coefficient user-defined (reference temperature: 5 to 95°C; temperature coefficient: ±5%/°C) TDS: Conversion using user-set coefficient (0.30 to 1.00) Temperature characteristics of NaCl (Temperature compensation for pure water automatically engages in the pure water range.) Power requirements 100 to 240 V AC ±10%, maximum 15 VA Power requirements 100 to 240 V AC ±10%, maximum 10 VA Conforming standards CE marking, FCC regulations Conforming standards CE marking, FCC regulations Compatible sensors ESH and FS series conductivity sensor (cell constant: 0.01/cm, 0.1/cm, 1.0/cm) Compatible sensors ESH carbon conductivity sensor (cell constant: 0.1/cm, 1.0/cm) For pharmaceutical / food processing Sanitary conductivity sensor Can also be used Pharmaceutical / food processing type conductivity sensor for applications that demand high sanitary levels with Steam-InPlace cleaning Flow-through sensor Insertion type sensor FS-01 Series ESH-01-C-S-SN Parts contacting fluids are straight and without projections. FS-01F-C-SL-2.5S For semiconductor wet cleaning Carbon conductivity sensor Electrodes made of highly chemical resistant glass carbon which allows for measurement in a wide range of chemicals used in semiconductor washing and other processes. Threaded type Threaded type ESH-01-L-GC5 ESH-1-L-GC9 ESH-01-C-S-SN-1.5S ESH-01-L-GC5-Y-10M FS-01 (flow-through type) Model Cell constant Wetted material Protective structure ESH-01-C-S-SN (insert type) Approx. 0.1/cm SUS316L*, PTFE, FKM Model ESH-01-L-GC5 ESH-1-L-GC9 Cell constant Approx. 0.1/cm Approx. 0.7/cm SUS316L*, PEEK, FKM (Compliant with MHLW Bulletin No. 20 and 85) IP67 equivalent Wetted material Electrode Body Pressure of fluid being measured 0 to 1 MPa Packing Pressure of fluid being measured Temperature of fluid being measured 0 to 100ºC Temperature of fluid being measured Steam sterilization Connection aperture (ferrule) Cable length Compatible converter 140°C/0.6 MPa within 60 minutes 15A, 1S, 1.5S, 2S, 2.5S 1.5S ESH-1-L-GC9-Y-10M Glass carbon PFA Kalrez® 0 to 0.5 MPa 0 to 80ºC Installation Threaded type; Thread diameter: R (PT) 3/4 Cable length 10 m, Y terminal (standard); limit cable extensions to a max. 100 m 10m (CK-10M), 20m (CK-20M), 30m (CK-30M) Holder to be combined Flow type holder EFA-30P, EFA-30F HE-960CW Compatible converter HE-480C-GC * Cannot be used with fluids (hydrochloric acid, diluted sulfuric acid, seawater, etc.) that chemically react with electrode (SUS316L). For ordering, refer to the model code chart on page 15. For ordering, refer to the model code chart on page 15. 7 Conductivity Meter (high concentration type) Conductivity meters (4-electrode type) Conductivity meter (rain-proof type) Conductivity meter (high concentration type) CEH-200 HE-480H 1 ch Rain-proof type Panel mount SLIM48 1 ch ● Employs five AC electrode sensors ● Automatic determination of sensor integrity ● Can continuously measure salinity and temperature of seawater ● Large custom LCD High concentration type ● Wide range measurement possible to 500 mS/cm*1 ● Equipped with a seawater salinity and NaCl salinity conversion function ● Supports a variety of temperature compensation ● Automatic determination of sensor integrity *1: For measurements over 200 mS/cm, wide range type HE-960HS model is recommended. Contact the sales for details. Model CEH-200 Sensor input Measurement method Electrode type (4-electrode method) 1-channel (cell constant: 1.0/cm) Temperature sensor Resistance thermometer: 1000 Ω/0°C Conductivity: 1.00/2.00/5.00/10.0/20.0 mS/cm Salinity: Conductivity Measurement 1000/2000/5000 µS/cm range 1-channel (cell constant: 1.0/cm) Sensor input Temperature sensor Resistance thermometer: 1000 Ω/0°C Measurement HE-480H Model Measurement method Electrode type (4-electrode method) range (mS/cm) 0.00 to 20.00 0.0 to 200.0 0.0 to 500.0 (S/m) 0.000 to 2.000 0.00 to 20.00 0.00 to 50.00 0 to 4.0% (operating temperature: 0 to 40°C) * Measurement in the 200.0 mS/cm and 20.00 S/m ranges is possible up to a custom temperature coefficient setting of ±3.5%/°C at a reference temperature of 25°C. (Selectable with function setting switch) * Measurement in the 500.0 mS/cm and 50.00 S/m ranges is possible without temperature compensation. *1 Temperature: 0 to 100°C (measurement only) Seawater salinity conversion: 0.00 to 4.00% Reproducibility ±0.5% FS (within ±1.0%FS at 1000 µS/cm) NaCl salinity conversion: 0.0 to 20.0% Transmission No. of outputs: 1; 4 to 20 mA DC; I/O insulation type (Transmission output of temperature is output not attached.); maximum load resistance 500 Ω Reproducibility Contact output No. of outputs: 2 Transmission output No. of outputs: 1; 4 to 20 mA DC; I/O insulation type; maximum load resistance 900 Ω Contact type: Relay contact SPDT (1c) Contact output Temperature: 0 to 100°C (The number of decimals displayed can be selected between none, 1, and 2.) ±0.5% FS (±1.0% for salinity conversion and the 500 mS/cm range) No. of outputs: 2 (R1 and R2) Contact rating: 250 V AC 3 A (resistance load) Contact type: Relay contact SPDT (1c) Contact function: Upper/lower limit operation (ON/OFF control) Contact rating: 240 V AC 3 A, 30 V DC 3 A (resistance load) Calibration Conductivity, salinity: Depends upon the cell constant setting function Temperature: One-point calibration at a known temperature Calibration Conductivity: Based on the specified compensation coefficient for the cell constant (parameter input) Temperature Based on the reference temperature and temperature coefficient user-defined (reference function Temperature: Calibrated by comparing with the reference thermometer Temperature Based on the reference temperature and temperature coefficient user-defined (reference compensation Contact function: Select between upper/lower limit operation (ON/OFF control), alarm, and maintenance. temperature: 5 to 95°C; temperature coefficient: ±5%/°C) Temperature characteristics of NaCl compensation Structure temperature: 5 to 95°C; temperature coefficient: ±5%/°C) Temperature characteristics of NaCl Power requirements 100 to 115 V AC or 200 to 240 V AC (as ordered), 7 VA (max.) Outdoor installation: JIS CO920; Protection level: 3 (rain-proof) Power requirements 100 to 240 V AC ±10%, maximum 10 VA Installation method: 50 A pole or wall attachment Conforming standards CE marking, FCC regulations Compatible sensors FES series conductivity sensor (cell constant: 1.0/cm) General-purpose Compatible sensors FES series conductivity sensor (cell constant: 1.0/cm) 4-electrode method conductivity sensor Model Cell constant Electrode Wetted Body material Packing Pressure of fluid being measured Temperature of fluid being measured Submersible type/Threaded type FES-100 Series Cable length Installation FES-126F FES-126FNi (Submersible type) (Threaded type) Holder to be combined Compatible converter FES-126FNi (for TMAH) FES-126F Approx. 0.1/cm Titanium Nickel Titanium PPS PPS PVC EPDM FKM FKM 0 to 0.5 MPa 0 to 0.5 MPa 0 to 0.5 MPa 0 to 120°C *1 0 to 120°C 0 to 50°C 10 m, Y terminal (standard); Use the CT-20EC relay box for further extension. Maximum extension length: 50 m 1. Submersible type 1. Submersible type Threaded type 2. Threaded type 2. Threaded type Thread diameter: R (PT) 3/4 Use the thread Use the thread adapter EA-20. adapter EA-40. Flow type holder: EF-20, EF-20P, EF-20S Flow type holder: EF-20P CEH-200, HE-480H, HE-960HS HE-960TM (for TMAH) FES-125F *1. Submersible types can only be used between 0 and 50°C For ordering, refer to the model code chart on page 15. ■ Accessories Relay box CT-20EC Sensor extension cable C-7E Connector cable SK-10M/20M/30M Flow type holder EF-20 Series Model Used for connecting the converter and the relay box. This cable is for connecting a connector type sensor to the indication converter. Liquid end materials Liquid pressure range Liquid temperature range Liquid flow rate Connected pipe diameter EF-20 EF-20P EF-20S PVC 0 to 50ºC 0 to 0.1 MPa PVDF 0 to 100ºC 0 to 0.1 MPa SUS 316 0 to 100ºC 0 to 0.5 MPa 0 to 10 L/min Inlet: Rc (PT) 1/2, Outlet: Rc (PT) 1/2 For ordering, refer to the model code chart on page 15. 8 Sanitary conductivity meter (4-electrode type) Carbon sensor conductivity meter (4-electrode type) Sanitary conductivity meter (wide range type) For pharmaceutical / food processing Carbon sensor conductivity meter (wide range type) HE-960HI HE-960HC Wide range type Panel mount DIN96 1 ch For Cleaning-in-Place (CIP) terminal management ● Measures the full range up to 500 mS/cm ● Automatic display range switching ● Equipped with nitric acid(HNO3), phosphoric acid(H3PO4), and sodium hydroxide (NaOH) concentration automatic conversion function ● Built-in RS-485 communications output Model Panel mount DIN96 1 ch For semiconductor wet cleaning Wide range type ● Carbon sensor compatible ● Measures the full range up to 1000 mS/cm ● Automatic display range switching ● Equipped with the chemical concentration conversion function ● Built-in RS-485 RoHS communications output COMPLIANT Model HE-960HI HE-960HC Measurement method Electrode type (4-electrode method) Measurement method Electrode type (4-electrode method) Sensor input Sensor input 1-channel (cell constant: 0.1/cm) 1-channel (cell constant: 0.1/cm) Temperature sensor Resistance thermometer: 1000 Ω/0°C Temperature sensor Resistance thermometer: 1000 Ω/0°C Measurement Conductivity: 0 to 200 mS/cm (Conductivity measurement range prior to temperature compensation: 0 to 500 mS/cm) Measurement Conductivity: 0 to 1000 mS/cm (Conductivity measurement range prior to temperature compensation) range Temperature: 0 to 100°C range Temperature: 20 to 150°C Concentration NaOH: 0 to 5%, HNO3: 0 to 5%, H3PO4: 0 to 5% (using internal program) Concentration conversion Custom 1: 0 to 100%, Custom 2: 0 to 100% (user-customizable conversion formula) conversion Custom 1: 0 to 100%, Custom 2: 0 to 100% (user-customizable conversion formula) Reproducibility Reproducibility ±0.5% FS (within ±1.0%FS at 500 mS/cm ranges) Transmission output No. of outputs: 4; 4 to 20 mA DC; I/O insulation type; maximum load resistance 900 Ω Contact output 0 to 20.00 mS/cm 20.0 to 200.0 mS/cm (equivalent input) 200 to 1000 mS/cm No. of outputs: 5 (R1, R2, R3, R4, and RF) Within ±1.0%FS Transmission output No. of outputs: 4; 4 to 20 mA DC/0 to 20 mA DC; I/O insulation type; maximum load resistance 900 Ω Contact type: Relay contacts R1 to R4: SPST (1a); RF: SPDT (1c) Contact output No. of outputs: 5 (R1, R2, R3, R4, and RF) Contact rating: 240 V AC 3 A, 30 V DC 3 A (resistance load) Contact type: Relay contacts R1 to R4: SPST (1a); RF: SPDT (1c) Contact function: Select between upper/lower limit operation (ON/OFF control), alarm, and Contact rating: 240 V AC 3 A, 30 V DC 3 A (resistance load) Contact function: Select between upper/lower limit operation (ON/OFF control), alarm, and maintenance. (R1 and R2·R3, and R4 and RF are for common use, maintenance. (R1 and R2·R3, and R4 and RF are for common use, respectively.) Contact Input Within ±0.5%FS respectively.) No. of inputs: 2 Contact function: Interchangeable transmission output range, External input for holding Contact Input Communications function RS-485 I/O No. of input: 1 Contact function: Transmission output for holding Calibration Conductivity: Based on the specified compensation coefficient for the cell constant (parameter input) Communications function RS-485 I/O function Temperature: Calibrated by comparing with the reference thermometer Calibration Conductivity: Based on the specified compensation coefficient for the cell constant (parameter input) Temperature Based on the reference temperature and temperature coefficient user-defined (reference temperature: 25°C; temperature coefficient: 0 to 5%/°C) function Temperature: Calibrated by comparing with the reference thermometer compensation Based on the temperature characteristics of NaCl (reference temperature: 25°C) Temperature compensation Based on the reference temperature and temperature coefficient user-defined (reference temperature: 25°C; temperature coefficient: 0 to 3%/°C) Power requirements 100 to 240 V AC ±10%, maximum 20 VA Power requirements 100 to 240 V AC ±10%, maximum 20 VA Conforming standards CE marking, FCC regulations Conforming standards CE marking, FCC regulations Compatible sensors FES-300 and FES-200 series conductivity sensor (cell constant: 0.1/cm) Compatible sensors FES-510 carbon conductivity sensor (cell constant: 1.0/cm) For pharmaceutical / food processing Sanitary conductivity sensor For semiconductor wet cleaning Carbon conductivity sensor Can also be used Pharmaceutical / food processing type conductivity sensor for applications that demand high sanitary levels with Steam-InPlace cleaning Electrodes made of highly chemical resistant glass carbon which allows for measurement in a wide range of chemicals used in semiconductor washing and other processes. Flow-through sensor Insertion type sensor Flow type carbon sensor FES-300 Series FES-200 Series FES-510 Series Parts contacting fluids are straight and without projections. FES-310-L-S-SN-3.0S FES-310 (flow-through type) Model Cell constant Wetted material Protective structure FES-510-3/4 FES-210-L-S-SN-2.0S FES-210, 220, 230, 240 (insert type) Approx. 0.1/cm SUS316L*, PPS, FKM (Compliant with MHLW Bulletin No. 20 and 85) IP67 equivalent Model FES-510 Cell constant Wetted material Electrode Body Pressure of fluid being measured 0 to 1 MPa Packing Pressure of fluid being measured Temperature of fluid being measured 0 to 110ºC Temperature of fluid being measured Steam sterilization Connection aperture (ferrule) Cable length Compatible converter 140°C/0.6 MPa within 60 minutes 1.5S, 2.0S, 2.5S, 3.0S, 4.0S, 4.5S 1.5S, 2.0S, VARIVENT® valve, Socket attachment type Cable-attached type: 10 m, Y terminal (standard); limit cable extensions to a max. 50 m Connector type: 10 m (SK-10M), 20 m (SK-20M), 30 m (SK-30M) Liquid flow rate Cable length HE-960HI * Cannot be used with fluids (hydrochloric acid, diluted sulfuric acid, seawater, etc.) that chemically react with electrode (SUS316L). For ordering, refer to the model code chart on page 15. Compatible converter Approx. 1.0/cm Glass carbon PFA Kalrez® 0 to 0.5 MPa (Within 5 to 50) 5 to 100ºC 0 to 2 L/min (1/4 in), 0 to 8 L/min (3/8 in) 0 to 10 L/min (1/2 in), 0 to 15 L/min (3/4 in) 0 to 25 L/min (1 in) Cable-attached type: 10 m, ring terminal (standard); limit cableextensions to a max. 50 m HE-960HC For ordering, refer to the model code chart on page 15. 9 External Dimensions ■Indication converter (Unit: mm) Resistivity meter / Conductivity meter ●Panel mount type 48 Series Panel cutting dimensions 115 48 92 +0.8 0 130 96 (Min.) 45 +0.6 0 70 (Min.) ●Panel mount type 96 Series 96 Panel cutting dimensions 115 92 0 +0.8 (Min.) 96 130 +0.8 92 0 118 (Min.) ●Rain-proof type 200 Series 230 50 180 100 70 220 180 40 20 260 155 35 35 35 60 35 ø60.5 210 222 (50A pole) *Sold separately Diagram shown here is an example of a pole attachment. Wall installation also available. ■Sensor ●Resistivity sensor ●Carbon resistivity sensor ERF-01-L-GC2 ERF-001 Series Cable-attached type ●Connector cable CK-■M (ø6.5) Connector type Cable length: L (ø6.5) Waterproof connector +5% 0 35 Required fluid level (ø13.8) 10 (ø13.8) (ø16) 50 ø26 ø32 10 R3/4 25 20 115.5 R 3/4 Across flats 29 55 (7) ø32 20 35.5 Required fluid level +5% 0 (ø6.5) 115.5 R 3/4 Across flats 29 25 Required fluid level 25 ø32 115.5 Across flats 29 20 35.5 ø26 10m ø26 50 10m ø21 Model Cable length +5% CK-Y10M 10 m 0 CK-Y20M 20 m +5% 0 CK-Y30M 30 m +5% 0 ■Sensor (Unit: mm) Our worldwide service network ensures speedy support, when and where you need it. ●2-electrode sanitary conductivity sensor ■Flow-through sensor FS-01 Series ■Connector cable CK- ■M ■Insertion type sensor ESH-01-C-S-SN-1.5S Maintenance space 50 or more Maintenance space 50 or more Cable length: L (ø6.5) 50 A B C øD A 2.5S (140) Model 82.5 (99.5) (103) (108.5) (114) (126.5) 55 85 110 65 75 Cable length +5% CK-Y10M 10 m 0 CK-Y20M 20 m +5% 0 CK-Y30M 30 m +5% 0 Japan China U.K. HORIBA INSTRUMENTS LIMITED HORIBA TRADING (SHANGHAI) CO., Ltd. HORIBA, Ltd. HORIBA Advanced Techno Co., Ltd. HORIBA STEC Co., Ltd. HORIBA TECHNO SERVICE Co., Ltd. Shanghai Office Beijing Office ø17 (ø50.5) ●4-electrode sanitary conductivity sensor 10m +5% 0 New Hampshire Office Santa Clara Office HORIBA Technology Center 10m Austin Office +5% 0 (105) HORIBA STEC Co., Ltd., Aso Factory 35 Depending on the coupling aperture of the sanitary ferrule Aperture 1.5S ø29 øB 2.0S 2.5S 3.0S 4.0S 4.5S øA 104 114 138 159 180 188 B (80.5) (86) (98) (109) (119.5) (123.5) 40 øA 73 (B) ) ( øA Portland Office (ø10) Maintenance space 100 or more Maintenance space 100 or more Clamp-on gasket (outside the scope of Horiba delivery) ■Insertion type sensor FES-210/220-L Series Cable-attached type (ø10) ■Flow-through sensor FES-310-L Series Cable-attached type Aperture 1.5S 2.0S øA 38.1 50.8 øB 50.5 64 (130) Germany France ■Flow-through sensor FES-310-C Series Connector type ■Connector cable SK- ■M HORIBA FRANCE SARL ■Insertion type sensor FES-210/220-C Series Connector type HORIBA EUROPE GmbH Singapore Taiwan HORIBA INSTRUMENTS PTE. Ltd. HORIBA, Ltd. TAIWAN Representative Office Korea HORIBA KOREA Ltd. U.S.A. HORIBA/STEC INCORPORATED Attach the SK series connector cable. Attach the SK series connector cable. 50 (ø10) Depending on the coupling aperture of the sanitary ferrule øA (91) 78 (B) ) ( øA Maintenance space 100 or more Maintenance space 100 or more Cable length: L Clamp-on gasket (outside the scope of Horiba delivery) Model 35 ø21 Cable length SK-Y10M ø29 øB +5% 10 m 0 +5% 0 SK-Y20M 20 m SK-Y30M 30 m +5% 0 40 (130) 2.5S 3.0S 4.0S 4.5S 104 114 138 159 180 188 B (80.5) (86) (98) (109) (119.5) (123.5) Maintenance space 100 or more ■Socket insertion type FES-240-L Cable-attached type (ø10) 10m +5% 0 FES-240-C Connector type ■VARIVENT® valve type FES-230-L Cable-attached type 10m (ø10) Attach the SK series connector cable. ø23.5 64 Please read the operation manual before using this product to assure safe and proper handling of the product. ● The contents of this catalog are subject to change without prior notice, and without any subsequent liability to this company. ● The color of the actual products may differ from the color pictured in this catalog due to printing limitations. ● It is strictly forbidden to copy the content of this catalog in part or in full. http://www.horiba-adt.jp/index_e.htm Head Office 31 Miyanonishicho, Kisshoin Minami-ku, Kyoto, Japan 601-8306 Phone: (81)75-321-7184 Fax: (81)75-321-7291 Attach the SK series connector cable. Tokyo Sales Office Arule-Bldg, Higashikanda. 4th Fl, 1-7-8 Higashi-Kanda Chiyoda-ku, Tokyo, Japan 101-0031 Phone: (81)3-3851-3150 Fax: (81)3-3851-3140 Nagoya Sales Office Sumitomoseimei Chigusa 2nd Bldg. 6th Fl, Aoi 3-15-31, Higashi-ku, Nagoya, Japan 461-0004 Phone: (81)52-937-0812 Fax: (81)52-937-0675 (ø84) (91) 78 32 (17) Socket (outside the scope of Horiba delivery) 50.5 ø38.1 (105) 78 32 (17) ø34.2 50.8 øB ø38.1 Keep at least 12 mm distance from the piping wall. ø23.5 Socket (outside the scope of Horiba delivery) 16 16 (106) 73.5 43.5 ø34.2 (86) 73.5 43.5 ø44.2 ø41.8 38.1 +5% 0 (ø84) ø44.2 ø41.8 2.0S øA FES-230-C Connector type ø29 Tuhenhagen DN40/50 plug Keep at least 12 mm distance from the piping wall. 2.0S øA Maintenance space 100 or more Aperture 1.5S Aperture 1.5S Service Stations ●Kyoto: (81)75-321-7972 ●Tokyo: (81)3-3851-3150 ●Nagoya: (81)52-937-0812 ø29 Bulletin:HAE-S0141C Tuhenhagen DN40/50 plug 13 Industrial Conductivity/Resistivity Meter Sanitary coupling ferrule 1.5S 85 B øD 1.0S 1.5S 2.0S (120) (120) (120) (120) 55.5 59 70 64.5 131 (175) C ø21 Aperture 15A Conductivity/Resistivity Meter Selection Guide & External Dimensions Attach the CK series connector cable. Attach the CK series connector cable. Clamp-on packing (outside the scope of Horiba delivery) Industrial 11 Printed in Japan 0902SK13 (Unit: mm) ●2-electrode conductivity sensor ERF-001 Series For flange mounting Cable-attached type Connector type Cable-attached type (ø6.5) Waterproof connector øA øA øA ESH-1 16 ESH-01 13.8 R 3/4 Required fluid level 165.5 ø22 ø32 75 20 35.5 R 3/4 Required fluid level Model Across flats 29 165.5 R 3/4 ø32 75 115.5 25 R 3/4 20 35.5 (7) Required fluid level ø26 Across flats 29 ø32 ø26 20 35.5 ø26 50 Across flats 29 115.5 ø32 25 Required fluid level 20 35.5 ø26 +5% 0 50 10m +5% 0 (7) Waterproof connector 10m Across flats 29 Connector type (ø6.5) ø22 ESH-001 13.8 øA ●2-electrode carbon conductivity sensor CK-■M ESH-1-L-GC9 (ø6.5) ø26 10m ø26 +5% 0 ●Flow type holder ●Connector cable EFA-30 Series Measurement fluid outlet Rc 3/4 Cable length: L (ø6.5) ESH-01-L-GC5 øA 10m +5% 0 ø34 (ø6.5) Required fluid level ø18 Measurement fluid inlet Rc 3/4 ø21 Across flats 29 ø32 Model ø18 ●4-electrode conductivity sensor Sensor attachment Rc 3/4 100 Cable length +5% 0 CK-Y10M 10 m CK-Y20M 20 m +5% 0 CK-Y30M 30 m +5% 0 ●Flow type holder FES-125F/FES-126F ●Relay box EF-20/EF-20S CT-20EC Measurement fluid outlet Rc 1/2 With threaded type adapter ø99.5 Cable length 10 m Cable length 10 m ø40 35 R3/4 15.5 50 43 Across flats 29 ø32 50 (78) Required fluid level 22.5 20 10 (25.5) 20 10 (26) R3/4 1 2 T T E 1 2 T T E (106) 25 ø34 35 Measurement fluid inlet Rc 1/2 ø28 238 Sensor attachment Rc 3/4 220 70 ■93 70 R(PT)3/4 98 ø20 Measurement fluid outlet Rc 1/2 EF-20P (193) 126.5 4-ø10 (50) ø35 Measurement fluid inlet Rc 1/2 ø50 ø20 71.5 35 50 (193) Required fluid level 98 161.5 Required fluid level For 25 A to 50 A pipes *Sold separately Sensor attachment Rc 3/4 220 122 ø36 50 (ø10) ø24 ø60 (ø10) ●4-electrode carbon conductivity sensor FES-510-1/2 13.5 (ø7) 70 2-ø7 (76.5) 50 4-Electrode Carbon Sensor FES-510 63 42 (142.5) 10 (76.5) 90 (20) 10 m +5% 0 (375) (142.5) (54.5) 2-ø7 10 4-Electrode Carbon Sensor FES-510 50 (142.5) 90 (20) (142.5) 63 42 10 m +5% 0 (375) (57.5) FES-510-3/4 13.5 (ø7) 70 12 ■Sensor (Unit: mm) Our worldwide service network ensures speedy support, when and where you need it. ●2-electrode sanitary conductivity sensor ■Flow-through sensor FS-01 Series ■Connector cable CK- ■M ■Insertion type sensor ESH-01-C-S-SN-1.5S Maintenance space 50 or more Maintenance space 50 or more Cable length: L (ø6.5) 50 A B C øD A 2.5S (140) Model 82.5 (99.5) (103) (108.5) (114) (126.5) 55 85 110 65 75 Cable length +5% CK-Y10M 10 m 0 CK-Y20M 20 m +5% 0 CK-Y30M 30 m +5% 0 Japan China U.K. HORIBA INSTRUMENTS LIMITED HORIBA TRADING (SHANGHAI) CO., Ltd. HORIBA, Ltd. HORIBA Advanced Techno Co., Ltd. HORIBA STEC Co., Ltd. HORIBA TECHNO SERVICE Co., Ltd. Shanghai Office Beijing Office ø17 (ø50.5) ●4-electrode sanitary conductivity sensor 10m +5% 0 New Hampshire Office Santa Clara Office HORIBA Technology Center 10m Austin Office +5% 0 (105) HORIBA STEC Co., Ltd., Aso Factory 35 Depending on the coupling aperture of the sanitary ferrule Aperture 1.5S ø29 øB 2.0S 2.5S 3.0S 4.0S 4.5S øA 104 114 138 159 180 188 B (80.5) (86) (98) (109) (119.5) (123.5) 40 øA 73 (B) ) ( øA Portland Office (ø10) Maintenance space 100 or more Maintenance space 100 or more Clamp-on gasket (outside the scope of Horiba delivery) ■Insertion type sensor FES-210/220-L Series Cable-attached type (ø10) ■Flow-through sensor FES-310-L Series Cable-attached type Aperture 1.5S 2.0S øA 38.1 50.8 øB 50.5 64 (130) Germany France ■Flow-through sensor FES-310-C Series Connector type ■Connector cable SK- ■M HORIBA FRANCE SARL ■Insertion type sensor FES-210/220-C Series Connector type HORIBA EUROPE GmbH Singapore Taiwan HORIBA INSTRUMENTS PTE. Ltd. HORIBA, Ltd. TAIWAN Representative Office Korea HORIBA KOREA Ltd. U.S.A. HORIBA/STEC INCORPORATED Attach the SK series connector cable. Attach the SK series connector cable. 50 (ø10) Depending on the coupling aperture of the sanitary ferrule øA (91) 78 (B) ) ( øA Maintenance space 100 or more Maintenance space 100 or more Cable length: L Clamp-on gasket (outside the scope of Horiba delivery) Model 35 ø21 Cable length SK-Y10M ø29 øB +5% 10 m 0 +5% 0 SK-Y20M 20 m SK-Y30M 30 m +5% 0 40 (130) 2.5S 3.0S 4.0S 4.5S 104 114 138 159 180 188 B (80.5) (86) (98) (109) (119.5) (123.5) Maintenance space 100 or more ■Socket insertion type FES-240-L Cable-attached type (ø10) 10m +5% 0 FES-240-C Connector type ■VARIVENT® valve type FES-230-L Cable-attached type 10m (ø10) Attach the SK series connector cable. ø23.5 64 Please read the operation manual before using this product to assure safe and proper handling of the product. ● The contents of this catalog are subject to change without prior notice, and without any subsequent liability to this company. ● The color of the actual products may differ from the color pictured in this catalog due to printing limitations. ● It is strictly forbidden to copy the content of this catalog in part or in full. http://www.horiba-adt.jp/index_e.htm Head Office 31 Miyanonishicho, Kisshoin Minami-ku, Kyoto, Japan 601-8306 Phone: (81)75-321-7184 Fax: (81)75-321-7291 Attach the SK series connector cable. Tokyo Sales Office Arule-Bldg, Higashikanda. 4th Fl, 1-7-8 Higashi-Kanda Chiyoda-ku, Tokyo, Japan 101-0031 Phone: (81)3-3851-3150 Fax: (81)3-3851-3140 Nagoya Sales Office Sumitomoseimei Chigusa 2nd Bldg. 6th Fl, Aoi 3-15-31, Higashi-ku, Nagoya, Japan 461-0004 Phone: (81)52-937-0812 Fax: (81)52-937-0675 (ø84) (91) 78 32 (17) Socket (outside the scope of Horiba delivery) 50.5 ø38.1 (105) 78 32 (17) ø34.2 50.8 øB ø38.1 Keep at least 12 mm distance from the piping wall. ø23.5 Socket (outside the scope of Horiba delivery) 16 16 (106) 73.5 43.5 ø34.2 (86) 73.5 43.5 ø44.2 ø41.8 38.1 +5% 0 (ø84) ø44.2 ø41.8 2.0S øA FES-230-C Connector type ø29 Tuhenhagen DN40/50 plug Keep at least 12 mm distance from the piping wall. 2.0S øA Maintenance space 100 or more Aperture 1.5S Aperture 1.5S Service Stations ●Kyoto: (81)75-321-7972 ●Tokyo: (81)3-3851-3150 ●Nagoya: (81)52-937-0812 ø29 Bulletin:HAE-S0141C Tuhenhagen DN40/50 plug 13 Industrial Conductivity/Resistivity Meter Sanitary coupling ferrule 1.5S 85 B øD 1.0S 1.5S 2.0S (120) (120) (120) (120) 55.5 59 70 64.5 131 (175) C ø21 Aperture 15A Conductivity/Resistivity Meter Selection Guide & External Dimensions Attach the CK series connector cable. Attach the CK series connector cable. Clamp-on packing (outside the scope of Horiba delivery) Industrial 11 Printed in Japan 0902SK13 (100 µS/m) (1000 µS/m) Cable-attached type Connector type Cable-attached type (ø6.5) Sterilized purified water, purified water R 3/4 R 3/4 Required fluid level Model Conductivity meter (low concentration type) CE-200C HE-480C ●2-electrode carbon conductivity sensor P6 P6 ø26 10m (Rain-proof type) 22.5 20 10 (25.5) Required fluid level 15.5 Across flats 29 ø32 R3/4 ø18 ■ Sanitary conductivity meter (low concentration type) Measurement fluid inlet Rc 3/4 Model CK-Y10M ø18 ●4-electrode conductivity sensor CK-Y20M 20 m CK-Y30M 30 m +5% 0 ●Relay box ø99.5 Measurement fluid inlet Rc 1/2 Conductivity meter (4-electrode method) Sensor attachment Rc 3/4 220 70 ø20 Measurement range: 0-100.0 MΩ·cm Carbon sensor ESH-01-L-GC5 Measurement range: 0-200 µS/cm Note: Measurement range listed in this document 2-channel resistivity meter 2 ch Ring terminal (option) N/A When the connector type sensor is selected Connector type*2 -C Electrode: SUS 316L, Electorde insulation: PEEK -S Sanitary type (Structure: compliant with IP67) -SN -1.5S Cell constant Connection Model Material Conductivity sensor (2-electrode method) Cell constant: 0.1/cm -01F Connector type*2 -C Electrode: SUS 316, Electorde insulation: PEEK -SL -15A IFD/ISO 15 ferrule -XX Designed cable length (option)*1 -1S IFD/ISO 1S ferrule N/A When the connector type sensor is selected -1.5S IFD/ISO 1.5S ferrule -2S IFD/ISO 2S ferrule -2.5S IFD/ISO 2.5S ferrule ø50 71.5 2-ø7 10 4-Electrode Carbon Sensor FES-510 (142.5) 50 90 (ø7) 63 42 (20) (142.5) Cell length Terminal type Cable length Panel mount 1 ch Rain-proof type RoHS -Y Y terminal (standard) -O Ring terminal (option) -10M 10 m (standard) -XX Designed cable length (option)*1 1 ch COMPLIANT -L Carbon sensor conductivity meter (low concentration type) 1 ch Panel mount Panel mount DIN96 ■ CEH-200 Conductivity meter (rain-proof type) ■ HE-480H Conductivity meter (high concentration type) Sanitary conductivity meter (wide range type) DIN96 DIN96 Resitivity sensor (ø7) 12 Model -L Cable-attached type -C Connector type*3 Cell constant Connection Material Temperature testing Terminal type Cable length RoHS -N -N No temperature testing (standard) -R -R With 0ºC temperature testing (option) -Y With pair calibration*1 -O With 0ºC temperature testing (option) -O Ring terminal (option) -XX Designated cable length (option) *2 When the connector type sensor is selected When the connector type sensor is selected *1 The sensor and converter are calibrated together before shipping. Contact your sales representative separately. Calibration accuracy (HE-960RW+ERF-001 sensor) Resistivity Within ±0.01 MΩ·cm Temperature Within ±0.02ºC Size In-line flow type -510 Piping size: 3/8 in. (substandard) Electrode: Nickel; Packing; EPDM (option) -1/2 Piping size: 1/2 in. (substandard) Threaded type adaptor required separately*4 -3/4 Piping size: 3/4 in. (standard) -1 Piping size: 1 in. (substandard) -6_4 Piping size: ø6/ø4 mm -10_8 Piping size: ø10/ø8 mm Specifications Connection Electrode material Structure Model -L -L Cable-attached type*1 -C -C Connector type*2 In-line flow-through type -310 Cable-attached type*1 Connector type*2 SUS316L, PPS, FKM -S SUS316L, PPS, FKM Connection Electrode material Structure Specifications 4-electrode conductivity sensor Insertion type (Ferrule attachment material: SUS) -S Size FES Sanitary type (Structure: IP67 equivalent) -SN Sanitary type (Structure: IP67 equivalent) -1.5S IFD/ISO 1.5S ferrule -1.5S IFD/ISO 1.5S ferrule -2.0S IFD/ISO 2.0S ferrule -2.0S IFD/ISO 2.0S ferrule -2.5S IFD/ISO 2.5S ferrule -3.0S IFD/ISO 3.0S ferrule -4.0S IFD/ISO 4.0S ferrule -4.5S IFD/ISO 4.5S ferrule Size Specifications 4-electrode conductivity sensor FES Insertion type (VARIVENT® valve attachment -230 -L Cable-attached type*1 -C Connector type*2 SS316L, PPS, FKM -DN50 VARIVENT® valve Accessories Flow type holder (For 4-electrode conductivity sensor) EF-20 Series (Compatible sensor: FES Series) Model -20 Insertion type (Socket attachment) -L Cable-attached type -C Connector type Cell constant Connection EF Socket attachment type Specifications Product name Model Flow type holder CT-20EC Relay box For 4-electrode method C-7E Exclusive-use extension cable (for 4-electrode conductivity sensors) SK-10M Connecter cable 10 m (for 4-electrode conductivity sensors) N/A PVC -P PVDF -S SUS-316 Threaded type adaptor Against reference device/ At same temperature *2 Limit cable extensions to a max. 50 m. (Relay boxes cannot be used.) *3 A connector cable (CK-10M/20M/30M, etc.) is separately required for connector type sensors. *4 Use a flow type holder (EFA-30/30P/30S) sold separately, if needed. *5 Use a flow type holder (EFA-31P/31F) sold separately, if needed. Size Made by order [Flow-through type] Insertion type (Ferrule attachment material: resin) -240 Specifications 4-electrode conductivity sensor -Ni -S N/A N/A Model FES -220 Ring terminal (option) 10 m (standard) Designated cable length (option) *2 FES-510 Series (Compatible converter: HE-960HC) [Flow type] -210 Y terminal (standard) -10 10 m (standard) Specifications 4-electrode conductivity sensor Model Y terminal (standard) -10 ■Carbon conductivity sensor (For semi-conductor and FPD manufacturing) [Custom insertion type] -Y -XX Connecter cable 30 m (for 2-electrode conductivity sensors) Piping size: 1/4 in. (standard) Specifications No temperature testing (standard) Titanium*4 CK-30M -3/8 -SN Electrode: Glass carbon; Body: PFA*5 -GC2 Connecter cable 20 m (for 2-electrode conductivity sensors) Made by order Electrode: Titanium; Packing: FKM (standard) Connection Electrode material Structure Model Cable-attached type -L CK-20M PFA N/A FES COMPLIANT Cell constant 0.1/cm -01 Connecter cable 10 m (for 2-electrode conductivity sensors) F -1/4 Resistivity sensor ERF Cell constant 0.01/cm (-S) 70 Specifications Designed cable length (option)*1 FES-200/300 Series (Compatible converter: HE-960HI) [Insertion type] ERF-01 Series (Compatible converters: HE-960RW-GC, HE-960R-GC) Temperature testing Terminal type Cable length Connecter cable 5 m (for 2-electrode conductivity sensors) CK-10M SUS-316 ■Sanitary conductivity sensor (For food and pharmaceutical manufacturing) ERF-001 Series (Compatible converters: HE-960RW, HE-480R) Electrode material CK-5M PVDF -S Cable-attached type*1 N/A Wide range type Panel mount 1 ch Carbon sensor conductivity meter (wide range type) Exclusive-use extension cable (for 2-electrode conductivity sensors) -P Submersible type (Body: PPS) N/A Wide range type Panel mount 1 ch 10 m (standard) Submersible type (Body: PVC) Wide range type DIN96 C-5C PVC *1 Limit cable extensions to max. 100 m. Relay box usage is recommended for cable extensions exceeding 30 m. *2 Separate connector cable (CK-10M/20M/30M etc.) required for connector type sensors. *3 Use a flow type holder (EFA-30/30P/30S) sold separately, if needed. *4 Use a flow type holder (EFA-31P/31F) sold separately, if needed. 4-electrode conductivity sensor High concentration type Panel mount -10M -XX Connection Electrode material Connection -125F SLIM48 1 ch Conductivity meter (wide range type) -T 13.5 Ring terminal (option) FES-100 Series (Compatible converter: CEH-200, HE-480H, HE-960HS) ■Carbon resistivity sensor (For semi-conductor and FPD manufacturing) Cell constant Connection Y terminal (standard) -O FES Panel mount 1 ch For 2-electrode method N/A *4 -Y ■4-electrode conductivity sensor (General-purpose) RoHS COMPLIANT Rain-proof type 1 ch Relay box 4-electrode conductivity sensor FES series Low concentration type SLIM48 Product name Model CT-20EC Electrode: glass carbon, Body: PFA N/A Low concentration type -30 Specifications Flow type holder Cable-attached type Low concentration type SLIM48 Cell constant Connection EFA Cell constant: 1/cm -1 Low concentration type Panel mount Model *4 COMPLIANT DIN96 Accessories Flow type holder (For resistivity sensors and 2-electrode conductivity sensors) EFA-30 Series (Compatible sensors: ERF, ESH Series) Electrode: glass carbon, Body: PP N/A DIN96 Specifications Electrode: glass carbon, Body: PFA RoHS Specifications Size FS 10 m (standard) -GC6 Panel mount IFD/ISO 1.5S ferrule -10 Cable-attached type SLIM48 ■Resistivity sensor (For ultra-pure water) Model (375) 13.5 Y terminal (standard) Cell constant 0.1/cm Panel mount 1 ch ■ HE-480C-GC -001 (76.5) 50 (20) 2-ø7 10 4-Electrode Carbon Sensor FES-510 70 2 1 ch 2 channel conductivity meter (low concentration type) ERF 63 42 (142.5) 90 10 m +5% 0 P7 For 25 A to 50 A pipes *Sold separately FES-510-1/2 (142.5) Carbon sensor ERF-01-L-GC2 Resistivity meter ■ HE-960CW ■ HE-960HC ●4-electrode carbon conductivity sensor (375) -Y -O -L DIN96 Resistivity sensor ERF series Sensor attachment Rc 3/4 220 FES-510-3/4 For flange mounting Conductivity sensor (2-electrode method) Panel mount 2 ch 2 ch ■ HE-960HI (50) 50 Measurement fluid inlet Rc 1/2 10 m +5% 0 HE-480C-GC -LG ESH Conductivity meter (low concentration type) ■ HE-960HS 4-ø10 35 ø20 For flow type holder*3 -126F ø35 (54.5) ■ Measurement fluid outlet Rc 1/2 EF-20P (193) 126.5 98 98 (193) 161.5 Required fluid level Cell constant: 0.1/cm -01 (Compatible converter: HE-480C-GC) Cell constant Connection Material Specifications Conductivity sensor (2-electrode method) [Flow-through type] (Compatible converters: HE-480C, HE-960CW) Titanium -ST EFA-30 Model 50 ø36 Measurement range: 0-2000 µS/cm ■ Carbon sensor conductivity meter + ø34 ø60 ø24 Required fluid level Flow-through sensor FS-01 Series ERF-001-C-T-S-Y-10M CT-20EC R(PT)3/4 P5 + HE-960RW Conductivity meter (rain-proof type) ■ HE-480C Measurement fluid outlet Rc 1/2 ø28 P5 EFA-30 Carbon sensor resistivity meter ■ CE-200C Conductivity meter (2-electrode method) +5% 0 ●Flow type holder P7 Semiconductor cleaning processes + •Material: PVC Size Structure SUS-316 -GC9 35 Pharmaceutical processes HE-960R-GC ■ HE-960R-GC +5% HE-960CW HE-960RW-GC CK-10M 2-channel resistivity meter ■ HE-480R 10 m 0 Cable length 10 m (ø10) Connector type*2 100 With threaded type adapter (ø10) -C -GC5 Sensor attachment Rc 3/4 Cable length EF-20/EF-20S Cable length 10 m Cable-attached type -01 ø34 ø21 Across flats 29 ø32 FES-125F/FES-126F ■ Carbon sensor resistivity meter •Cell constant 0.01/cm •Cable attached type •Electrode material: Titanium •Pair calibration •Cable: 10m, Y termial •Material: PVC Product name ■ HE-960RW-GC Measurement range: 0-200 µS/cm * When used in conjunction with the CE-200C, measurement ranges expand to 10 µS/cm Food and beverage processes + ■ HE-960RW Resistivity meter Measurement fluid outlet Rc 3/4 (ø6.5) Required fluid level -L Flow type holder Resistivity sensor Model (76.5) Measurement range: 0-20 µS/cm Measurement range: 0-100.0 MΩ·cm (78) (106) Conductivity sensor ESH-01 R3/4 50 43 Conductivity sensor ESH-001 Resistivity sensor ERF-001 Series +5% 0 1 2 T T E Distilling plants •10 m •Y terminal Model EFA-30 Series Cable length: L 10m Cell constant 0.01/cm -T 2-channel resistivity meter Flow type holder 25 1 2 T T E Industrial water ø26 +5% 0 -001 -S Conductivity/Resistivity indication converter øA CK-■M (ø6.5) (ø6.5) P4 ESH-01-C-T-ST ●Flow type holder ●Connector cable ESH-1-L-GC9 Cell constant 0.1/cm Cell constant Connection Material ■Carbon conductivity sensor (For semi-conductors and FPD manufacturing) øA ESH-01-L-GC5 P4 13.8 238 HE-480R ESH-01 + 122 HE-960RW ■ Conductivity meter ø22 Connector cable ESH Cell constant 1.0/cm Sensor (connector type) ESH-001 13.8 20 10 (26) Pure water Ultra pure water ■ Resistivity meter øA 16 2-electrode conductivity sensor •Cell constant 0.1/cm •Connector type •Electrode material: Titanium •For dedicated holder HE-480C ESH-1 Connector cable Relay box (option) Model Conductivity sensor (2-electrode method) -01 (Example 2) Conductivity (low concentration type) R 3/4 Required fluid level øA Extension cable (option) [Insertion type] (Compatible converters: HE-480C, HE-960CW) Specifications -1 Holder attachment (option) (Example 1) ø32 ■Sanitary conductivity sensor (For food and pharmaceutical manufacturing) Cell constant Connection Electrode material Cell length Terminal type Cable length ESH Sensor (cable-attached type) Relay box (option) Indication converter ø26 (57.5) ■ 2-channel resistivity meter ■ Conductivity meter (low concentration type) øA ø22 50 Resistivity y meter R 3/4 Extension cable (option) 70 ■93 Water for Injection Required fluid level Across flats 29 20 35.5 Required fluid level ø32 75 Rain water Across flats 29 ø32 +5% 0 ø26 115.5 Distilled water Across flats 29 25 Pure water 25 Ultra pure water Sample examples ø32 115.5 Across flats 29 ø26 (7) ø26 20 35.5 100 KΩ·cm 20 35.5 1 MΩ·cm 10 MΩ·cm 18.24 Communications output Waterproof connector 10m +5% 0 50 10m 100 MΩ·cm Transmission output Connector type (ø6.5) Waterproof connector Resistivity Model For flange mounting 165.5 (10 µS/m) ERF-001 Series 20 35.5 10 µS/cm 50 1 µS/cm 2-electrode conductivity sensor ESH, FS series ■2-electrode conductivity sensor (General-purpose) (Compatible converters: CE-200C, HE-480C, HE-960CW) [Standard assembly] (7) 0.0548 (1 µS/m) 0.1 µS/cm (Unit: mm) ●2-electrode conductivity sensor ø40 35 (SI unit) 0.01 µS/cm 2-electrode conductivity Industrial Selection Guide for Conductivity Meter/Resistivity Meter 75 Resistivity Measurement principle Conductivity The industrialtechnology and Conductivity Meter and Resistivity Meter Lineups 165.5 Industrial *1 For cable extensions, use relay box CT-20EC and limit extension to a max. of 50 m. *2 Separate connector cable (SK-10M etc.) required for connector type sensors. *3 Use a flow type holder (EFA-30/30P/30S) sold separately, if needed. *4 Separate threaded type adaptors EA-20 (for FES-125 sensors) and EA-40 (for FES-126 sensors) required. 14 Model Product name EA-20 Threaded type adaptor (for FES-125 sensor); Material: PVC EA-40 Threaded type adaptor (for FES-126 sensor); Material: PVDF The contents of this catalogue describe a standard specifications and codes. For custom specification according to your special needs, please contact our sales department. 15 (100 µS/m) (1000 µS/m) Cable-attached type Connector type Cable-attached type (ø6.5) Sterilized purified water, purified water R 3/4 R 3/4 Required fluid level Model Conductivity meter (low concentration type) CE-200C HE-480C ●2-electrode carbon conductivity sensor P6 P6 ø26 10m (Rain-proof type) 22.5 20 10 (25.5) Required fluid level 15.5 Across flats 29 ø32 R3/4 ø18 ■ Sanitary conductivity meter (low concentration type) Measurement fluid inlet Rc 3/4 Model CK-Y10M ø18 ●4-electrode conductivity sensor CK-Y20M 20 m CK-Y30M 30 m +5% 0 ●Relay box ø99.5 Measurement fluid inlet Rc 1/2 Conductivity meter (4-electrode method) Sensor attachment Rc 3/4 220 70 ø20 Measurement range: 0-100.0 MΩ·cm Carbon sensor ESH-01-L-GC5 Measurement range: 0-200 µS/cm Note: Measurement range listed in this document 2-channel resistivity meter 2 ch Ring terminal (option) N/A When the connector type sensor is selected Connector type*2 -C Electrode: SUS 316L, Electorde insulation: PEEK -S Sanitary type (Structure: compliant with IP67) -SN -1.5S Cell constant Connection Model Material Conductivity sensor (2-electrode method) Cell constant: 0.1/cm -01F Connector type*2 -C Electrode: SUS 316, Electorde insulation: PEEK -SL -15A IFD/ISO 15 ferrule -XX Designed cable length (option)*1 -1S IFD/ISO 1S ferrule N/A When the connector type sensor is selected -1.5S IFD/ISO 1.5S ferrule -2S IFD/ISO 2S ferrule -2.5S IFD/ISO 2.5S ferrule ø50 71.5 2-ø7 10 4-Electrode Carbon Sensor FES-510 (142.5) 50 90 (ø7) 63 42 (20) (142.5) Cell length Terminal type Cable length Panel mount 1 ch Rain-proof type RoHS -Y Y terminal (standard) -O Ring terminal (option) -10M 10 m (standard) -XX Designed cable length (option)*1 1 ch COMPLIANT -L Carbon sensor conductivity meter (low concentration type) 1 ch Panel mount Panel mount DIN96 ■ CEH-200 Conductivity meter (rain-proof type) ■ HE-480H Conductivity meter (high concentration type) Sanitary conductivity meter (wide range type) DIN96 DIN96 Resitivity sensor (ø7) 12 Model -L Cable-attached type -C Connector type*3 Cell constant Connection Material Temperature testing Terminal type Cable length RoHS -N -N No temperature testing (standard) -R -R With 0ºC temperature testing (option) -Y With pair calibration*1 -O With 0ºC temperature testing (option) -O Ring terminal (option) -XX Designated cable length (option) *2 When the connector type sensor is selected When the connector type sensor is selected *1 The sensor and converter are calibrated together before shipping. Contact your sales representative separately. Calibration accuracy (HE-960RW+ERF-001 sensor) Resistivity Within ±0.01 MΩ·cm Temperature Within ±0.02ºC Size In-line flow type -510 Piping size: 3/8 in. (substandard) Electrode: Nickel; Packing; EPDM (option) -1/2 Piping size: 1/2 in. (substandard) Threaded type adaptor required separately*4 -3/4 Piping size: 3/4 in. (standard) -1 Piping size: 1 in. (substandard) -6_4 Piping size: ø6/ø4 mm -10_8 Piping size: ø10/ø8 mm Specifications Connection Electrode material Structure Model -L -L Cable-attached type*1 -C -C Connector type*2 In-line flow-through type -310 Cable-attached type*1 Connector type*2 SUS316L, PPS, FKM -S SUS316L, PPS, FKM Connection Electrode material Structure Specifications 4-electrode conductivity sensor Insertion type (Ferrule attachment material: SUS) -S Size FES Sanitary type (Structure: IP67 equivalent) -SN Sanitary type (Structure: IP67 equivalent) -1.5S IFD/ISO 1.5S ferrule -1.5S IFD/ISO 1.5S ferrule -2.0S IFD/ISO 2.0S ferrule -2.0S IFD/ISO 2.0S ferrule -2.5S IFD/ISO 2.5S ferrule -3.0S IFD/ISO 3.0S ferrule -4.0S IFD/ISO 4.0S ferrule -4.5S IFD/ISO 4.5S ferrule Size Specifications 4-electrode conductivity sensor FES Insertion type (VARIVENT® valve attachment -230 -L Cable-attached type*1 -C Connector type*2 SS316L, PPS, FKM -DN50 VARIVENT® valve Accessories Flow type holder (For 4-electrode conductivity sensor) EF-20 Series (Compatible sensor: FES Series) Model -20 Insertion type (Socket attachment) -L Cable-attached type -C Connector type Cell constant Connection EF Socket attachment type Specifications Product name Model Flow type holder CT-20EC Relay box For 4-electrode method C-7E Exclusive-use extension cable (for 4-electrode conductivity sensors) SK-10M Connecter cable 10 m (for 4-electrode conductivity sensors) N/A PVC -P PVDF -S SUS-316 Threaded type adaptor Against reference device/ At same temperature *2 Limit cable extensions to a max. 50 m. (Relay boxes cannot be used.) *3 A connector cable (CK-10M/20M/30M, etc.) is separately required for connector type sensors. *4 Use a flow type holder (EFA-30/30P/30S) sold separately, if needed. *5 Use a flow type holder (EFA-31P/31F) sold separately, if needed. Size Made by order [Flow-through type] Insertion type (Ferrule attachment material: resin) -240 Specifications 4-electrode conductivity sensor -Ni -S N/A N/A Model FES -220 Ring terminal (option) 10 m (standard) Designated cable length (option) *2 FES-510 Series (Compatible converter: HE-960HC) [Flow type] -210 Y terminal (standard) -10 10 m (standard) Specifications 4-electrode conductivity sensor Model Y terminal (standard) -10 ■Carbon conductivity sensor (For semi-conductor and FPD manufacturing) [Custom insertion type] -Y -XX Connecter cable 30 m (for 2-electrode conductivity sensors) Piping size: 1/4 in. (standard) Specifications No temperature testing (standard) Titanium*4 CK-30M -3/8 -SN Electrode: Glass carbon; Body: PFA*5 -GC2 Connecter cable 20 m (for 2-electrode conductivity sensors) Made by order Electrode: Titanium; Packing: FKM (standard) Connection Electrode material Structure Model Cable-attached type -L CK-20M PFA N/A FES COMPLIANT Cell constant 0.1/cm -01 Connecter cable 10 m (for 2-electrode conductivity sensors) F -1/4 Resistivity sensor ERF Cell constant 0.01/cm (-S) 70 Specifications Designed cable length (option)*1 FES-200/300 Series (Compatible converter: HE-960HI) [Insertion type] ERF-01 Series (Compatible converters: HE-960RW-GC, HE-960R-GC) Temperature testing Terminal type Cable length Connecter cable 5 m (for 2-electrode conductivity sensors) CK-10M SUS-316 ■Sanitary conductivity sensor (For food and pharmaceutical manufacturing) ERF-001 Series (Compatible converters: HE-960RW, HE-480R) Electrode material CK-5M PVDF -S Cable-attached type*1 N/A Wide range type Panel mount 1 ch Carbon sensor conductivity meter (wide range type) Exclusive-use extension cable (for 2-electrode conductivity sensors) -P Submersible type (Body: PPS) N/A Wide range type Panel mount 1 ch 10 m (standard) Submersible type (Body: PVC) Wide range type DIN96 C-5C PVC *1 Limit cable extensions to max. 100 m. Relay box usage is recommended for cable extensions exceeding 30 m. *2 Separate connector cable (CK-10M/20M/30M etc.) required for connector type sensors. *3 Use a flow type holder (EFA-30/30P/30S) sold separately, if needed. *4 Use a flow type holder (EFA-31P/31F) sold separately, if needed. 4-electrode conductivity sensor High concentration type Panel mount -10M -XX Connection Electrode material Connection -125F SLIM48 1 ch Conductivity meter (wide range type) -T 13.5 Ring terminal (option) FES-100 Series (Compatible converter: CEH-200, HE-480H, HE-960HS) ■Carbon resistivity sensor (For semi-conductor and FPD manufacturing) Cell constant Connection Y terminal (standard) -O FES Panel mount 1 ch For 2-electrode method N/A *4 -Y ■4-electrode conductivity sensor (General-purpose) RoHS COMPLIANT Rain-proof type 1 ch Relay box 4-electrode conductivity sensor FES series Low concentration type SLIM48 Product name Model CT-20EC Electrode: glass carbon, Body: PFA N/A Low concentration type -30 Specifications Flow type holder Cable-attached type Low concentration type SLIM48 Cell constant Connection EFA Cell constant: 1/cm -1 Low concentration type Panel mount Model *4 COMPLIANT DIN96 Accessories Flow type holder (For resistivity sensors and 2-electrode conductivity sensors) EFA-30 Series (Compatible sensors: ERF, ESH Series) Electrode: glass carbon, Body: PP N/A DIN96 Specifications Electrode: glass carbon, Body: PFA RoHS Specifications Size FS 10 m (standard) -GC6 Panel mount IFD/ISO 1.5S ferrule -10 Cable-attached type SLIM48 ■Resistivity sensor (For ultra-pure water) Model (375) 13.5 Y terminal (standard) Cell constant 0.1/cm Panel mount 1 ch ■ HE-480C-GC -001 (76.5) 50 (20) 2-ø7 10 4-Electrode Carbon Sensor FES-510 70 2 1 ch 2 channel conductivity meter (low concentration type) ERF 63 42 (142.5) 90 10 m +5% 0 P7 For 25 A to 50 A pipes *Sold separately FES-510-1/2 (142.5) Carbon sensor ERF-01-L-GC2 Resistivity meter ■ HE-960CW ■ HE-960HC ●4-electrode carbon conductivity sensor (375) -Y -O -L DIN96 Resistivity sensor ERF series Sensor attachment Rc 3/4 220 FES-510-3/4 For flange mounting Conductivity sensor (2-electrode method) Panel mount 2 ch 2 ch ■ HE-960HI (50) 50 Measurement fluid inlet Rc 1/2 10 m +5% 0 HE-480C-GC -LG ESH Conductivity meter (low concentration type) ■ HE-960HS 4-ø10 35 ø20 For flow type holder*3 -126F ø35 (54.5) ■ Measurement fluid outlet Rc 1/2 EF-20P (193) 126.5 98 98 (193) 161.5 Required fluid level Cell constant: 0.1/cm -01 (Compatible converter: HE-480C-GC) Cell constant Connection Material Specifications Conductivity sensor (2-electrode method) [Flow-through type] (Compatible converters: HE-480C, HE-960CW) Titanium -ST EFA-30 Model 50 ø36 Measurement range: 0-2000 µS/cm ■ Carbon sensor conductivity meter + ø34 ø60 ø24 Required fluid level Flow-through sensor FS-01 Series ERF-001-C-T-S-Y-10M CT-20EC R(PT)3/4 P5 + HE-960RW Conductivity meter (rain-proof type) ■ HE-480C Measurement fluid outlet Rc 1/2 ø28 P5 EFA-30 Carbon sensor resistivity meter ■ CE-200C Conductivity meter (2-electrode method) +5% 0 ●Flow type holder P7 Semiconductor cleaning processes + •Material: PVC Size Structure SUS-316 -GC9 35 Pharmaceutical processes HE-960R-GC ■ HE-960R-GC +5% HE-960CW HE-960RW-GC CK-10M 2-channel resistivity meter ■ HE-480R 10 m 0 Cable length 10 m (ø10) Connector type*2 100 With threaded type adapter (ø10) -C -GC5 Sensor attachment Rc 3/4 Cable length EF-20/EF-20S Cable length 10 m Cable-attached type -01 ø34 ø21 Across flats 29 ø32 FES-125F/FES-126F ■ Carbon sensor resistivity meter •Cell constant 0.01/cm •Cable attached type •Electrode material: Titanium •Pair calibration •Cable: 10m, Y termial •Material: PVC Product name ■ HE-960RW-GC Measurement range: 0-200 µS/cm * When used in conjunction with the CE-200C, measurement ranges expand to 10 µS/cm Food and beverage processes + ■ HE-960RW Resistivity meter Measurement fluid outlet Rc 3/4 (ø6.5) Required fluid level -L Flow type holder Resistivity sensor Model (76.5) Measurement range: 0-20 µS/cm Measurement range: 0-100.0 MΩ·cm (78) (106) Conductivity sensor ESH-01 R3/4 50 43 Conductivity sensor ESH-001 Resistivity sensor ERF-001 Series +5% 0 1 2 T T E Distilling plants •10 m •Y terminal Model EFA-30 Series Cable length: L 10m Cell constant 0.01/cm -T 2-channel resistivity meter Flow type holder 25 1 2 T T E Industrial water ø26 +5% 0 -001 -S Conductivity/Resistivity indication converter øA CK-■M (ø6.5) (ø6.5) P4 ESH-01-C-T-ST ●Flow type holder ●Connector cable ESH-1-L-GC9 Cell constant 0.1/cm Cell constant Connection Material ■Carbon conductivity sensor (For semi-conductors and FPD manufacturing) øA ESH-01-L-GC5 P4 13.8 238 HE-480R ESH-01 + 122 HE-960RW ■ Conductivity meter ø22 Connector cable ESH Cell constant 1.0/cm Sensor (connector type) ESH-001 13.8 20 10 (26) Pure water Ultra pure water ■ Resistivity meter øA 16 2-electrode conductivity sensor •Cell constant 0.1/cm •Connector type •Electrode material: Titanium •For dedicated holder HE-480C ESH-1 Connector cable Relay box (option) Model Conductivity sensor (2-electrode method) -01 (Example 2) Conductivity (low concentration type) R 3/4 Required fluid level øA Extension cable (option) [Insertion type] (Compatible converters: HE-480C, HE-960CW) Specifications -1 Holder attachment (option) (Example 1) ø32 ■Sanitary conductivity sensor (For food and pharmaceutical manufacturing) Cell constant Connection Electrode material Cell length Terminal type Cable length ESH Sensor (cable-attached type) Relay box (option) Indication converter ø26 (57.5) ■ 2-channel resistivity meter ■ Conductivity meter (low concentration type) øA ø22 50 Resistivity y meter R 3/4 Extension cable (option) 70 ■93 Water for Injection Required fluid level Across flats 29 20 35.5 Required fluid level ø32 75 Rain water Across flats 29 ø32 +5% 0 ø26 115.5 Distilled water Across flats 29 25 Pure water 25 Ultra pure water Sample examples ø32 115.5 Across flats 29 ø26 (7) ø26 20 35.5 100 KΩ·cm 20 35.5 1 MΩ·cm 10 MΩ·cm 18.24 Communications output Waterproof connector 10m +5% 0 50 10m 100 MΩ·cm Transmission output Connector type (ø6.5) Waterproof connector Resistivity Model For flange mounting 165.5 (10 µS/m) ERF-001 Series 20 35.5 10 µS/cm 50 1 µS/cm 2-electrode conductivity sensor ESH, FS series ■2-electrode conductivity sensor (General-purpose) (Compatible converters: CE-200C, HE-480C, HE-960CW) [Standard assembly] (7) 0.0548 (1 µS/m) 0.1 µS/cm (Unit: mm) ●2-electrode conductivity sensor ø40 35 (SI unit) 0.01 µS/cm 2-electrode conductivity Industrial Selection Guide for Conductivity Meter/Resistivity Meter 75 Resistivity Measurement principle Conductivity The industrialtechnology and Conductivity Meter and Resistivity Meter Lineups 165.5 Industrial *1 For cable extensions, use relay box CT-20EC and limit extension to a max. of 50 m. *2 Separate connector cable (SK-10M etc.) required for connector type sensors. *3 Use a flow type holder (EFA-30/30P/30S) sold separately, if needed. *4 Separate threaded type adaptors EA-20 (for FES-125 sensors) and EA-40 (for FES-126 sensors) required. 14 Model Product name EA-20 Threaded type adaptor (for FES-125 sensor); Material: PVC EA-40 Threaded type adaptor (for FES-126 sensor); Material: PVDF The contents of this catalogue describe a standard specifications and codes. For custom specification according to your special needs, please contact our sales department. 15 ■Sensor (Unit: mm) Our worldwide service network ensures speedy support, when and where you need it. ●2-electrode sanitary conductivity sensor ■Flow-through sensor FS-01 Series ■Connector cable CK- ■M ■Insertion type sensor ESH-01-C-S-SN-1.5S Maintenance space 50 or more Maintenance space 50 or more Cable length: L (ø6.5) 50 A B C øD A 2.5S (140) Model 82.5 (99.5) (103) (108.5) (114) (126.5) 55 85 110 65 75 Cable length +5% CK-Y10M 10 m 0 CK-Y20M 20 m +5% 0 CK-Y30M 30 m +5% 0 Japan China U.K. HORIBA INSTRUMENTS LIMITED HORIBA TRADING (SHANGHAI) CO., Ltd. HORIBA, Ltd. HORIBA Advanced Techno Co., Ltd. HORIBA STEC Co., Ltd. HORIBA TECHNO SERVICE Co., Ltd. Shanghai Office Beijing Office ø17 (ø50.5) ●4-electrode sanitary conductivity sensor 10m +5% 0 New Hampshire Office Santa Clara Office HORIBA Technology Center 10m Austin Office +5% 0 (105) HORIBA STEC Co., Ltd., Aso Factory 35 Depending on the coupling aperture of the sanitary ferrule Aperture 1.5S ø29 øB 2.0S 2.5S 3.0S 4.0S 4.5S øA 104 114 138 159 180 188 B (80.5) (86) (98) (109) (119.5) (123.5) 40 øA 73 (B) ) ( øA Portland Office (ø10) Maintenance space 100 or more Maintenance space 100 or more Clamp-on gasket (outside the scope of Horiba delivery) ■Insertion type sensor FES-210/220-L Series Cable-attached type (ø10) ■Flow-through sensor FES-310-L Series Cable-attached type Aperture 1.5S 2.0S øA 38.1 50.8 øB 50.5 64 (130) Germany France ■Flow-through sensor FES-310-C Series Connector type ■Connector cable SK- ■M HORIBA FRANCE SARL ■Insertion type sensor FES-210/220-C Series Connector type HORIBA EUROPE GmbH Singapore Taiwan HORIBA INSTRUMENTS PTE. Ltd. HORIBA, Ltd. TAIWAN Representative Office Korea HORIBA KOREA Ltd. U.S.A. HORIBA/STEC INCORPORATED Attach the SK series connector cable. Attach the SK series connector cable. 50 (ø10) Depending on the coupling aperture of the sanitary ferrule øA (91) 78 (B) ) ( øA Maintenance space 100 or more Maintenance space 100 or more Cable length: L Clamp-on gasket (outside the scope of Horiba delivery) Model 35 ø21 Cable length SK-Y10M ø29 øB +5% 10 m 0 +5% 0 SK-Y20M 20 m SK-Y30M 30 m +5% 0 40 (130) 2.5S 3.0S 4.0S 4.5S 104 114 138 159 180 188 B (80.5) (86) (98) (109) (119.5) (123.5) Maintenance space 100 or more ■Socket insertion type FES-240-L Cable-attached type (ø10) 10m +5% 0 FES-240-C Connector type ■VARIVENT® valve type FES-230-L Cable-attached type 10m (ø10) Attach the SK series connector cable. ø23.5 64 Please read the operation manual before using this product to assure safe and proper handling of the product. ● The contents of this catalog are subject to change without prior notice, and without any subsequent liability to this company. ● The color of the actual products may differ from the color pictured in this catalog due to printing limitations. ● It is strictly forbidden to copy the content of this catalog in part or in full. http://www.horiba-adt.jp/index_e.htm Head Office 31 Miyanonishicho, Kisshoin Minami-ku, Kyoto, Japan 601-8306 Phone: (81)75-321-7184 Fax: (81)75-321-7291 Attach the SK series connector cable. Tokyo Sales Office Arule-Bldg, Higashikanda. 4th Fl, 1-7-8 Higashi-Kanda Chiyoda-ku, Tokyo, Japan 101-0031 Phone: (81)3-3851-3150 Fax: (81)3-3851-3140 Nagoya Sales Office Sumitomoseimei Chigusa 2nd Bldg. 6th Fl, Aoi 3-15-31, Higashi-ku, Nagoya, Japan 461-0004 Phone: (81)52-937-0812 Fax: (81)52-937-0675 (ø84) (91) 78 32 (17) Socket (outside the scope of Horiba delivery) 50.5 ø38.1 (105) 78 32 (17) ø34.2 50.8 øB ø38.1 Keep at least 12 mm distance from the piping wall. ø23.5 Socket (outside the scope of Horiba delivery) 16 16 (106) 73.5 43.5 ø34.2 (86) 73.5 43.5 ø44.2 ø41.8 38.1 +5% 0 (ø84) ø44.2 ø41.8 2.0S øA FES-230-C Connector type ø29 Tuhenhagen DN40/50 plug Keep at least 12 mm distance from the piping wall. 2.0S øA Maintenance space 100 or more Aperture 1.5S Aperture 1.5S Service Stations ●Kyoto: (81)75-321-7972 ●Tokyo: (81)3-3851-3150 ●Nagoya: (81)52-937-0812 ø29 Bulletin:HAE-S0141C Tuhenhagen DN40/50 plug 13 Industrial Conductivity/Resistivity Meter Sanitary coupling ferrule 1.5S 85 B øD 1.0S 1.5S 2.0S (120) (120) (120) (120) 55.5 59 70 64.5 131 (175) C ø21 Aperture 15A Conductivity/Resistivity Meter Selection Guide & External Dimensions Attach the CK series connector cable. Attach the CK series connector cable. Clamp-on packing (outside the scope of Horiba delivery) Industrial 11 Printed in Japan 0902SK13