dermaTOP - Breuckmann
Transcription
dermaTOP - Breuckmann
APPLICATION REPORT dermaTOP Reliable analysis of wrinkles in 3D Juvenile, wrinkle-free skin all the way into old age — these are properties many skincare products promise to deliver. The human skin as a natural barrier against environmental influences is expected to look fresh and healthy at all times. Whether an active agent, a treatment or a cream does indeed deliver these desired miracles can now be verified through three-dimensional skin assessments with the aid of a dermaTOP scanning system: the effectiveness of a product is being scientifically examined with wrinkles measurements in long-term studies. The in-vivo scanner dermaTOP Objective and advantages In order to conduct precise measurements and evaluations of the human skin, the 3D in-vivo scanning system dermaTOP of the Breuckmann GmbH has been specifically optimized for applications in the fields of dermatology and cosmetics. The system is being successfully employed in the context of verification of the effectiveness of antiwrinkle, skin tightening and skin smoothening products. The effectiveness is verified on the basis of analyzing the so-called crow’s feet, wrinkles developing at the left and right outside corner of the eye. In the past, effectiveness analysis often required time consuming skin replica which could then be assessed by means of 2D image evaluation methods. Thanks to the functionality extension into the third dimension, the dermaTOP makes it possible not only to evaluate the roughness profiles of a surface, but also to measure the alteration of the wrinkle volumes, thus allowing verified conclusions to be drawn with regard to the effectiveness of a skincare product. Typically, the system is used by cosmetic manufacturers for the purpose of scientifically substantiated wrinkle analysis in their quest for research and development of ingredients and end products. But also independent testing laboratories verifying the effectiveness of skincare products, are successfully applying the dermaTOP. The sensor of the dermaTOP system is equipped with a blue LED light source, allowing it to achieve a optimum representation of the skin structure. The extremely fast measurement value acquisition of the scanner allows for a direct in-vivo analysis. Measuring system and setup In order to analyze the effectiveness of the test products or their respective active ingredients, longterm assessment studies are necessary. To ensure the exact reproducibility of the test person’s positioning over the course of several measurements and over an extended period of time, the especially for this purpose developed visioTOP 500 Workbench is being used. Workflow The positioning of the scanner to the test person is easily and swiftly carried out by mechanically adjusting the exact location of the examination area through software-supported positioning aids in the live image. Following the image capture, the 3D data is evaluated and visualized. Using intelligent alignment options provided by the software, it is ensured that always the same area is relevant for the assessment is being scanned and evaluated. The visioTOP 500 Workbench allows for an easy positioning of the measuring system (left), the scanner‘s blue light allows for a representation of the skin structure at optimum contrast (right) Since the subsequent analysis is conducted only on the basis of the wrinkle profile, the software automatically prepares the data in such a way that the Result three-dimensional information of the wrinkle profile (macro structure) is provided as an extract of the 3D information of the micro skin profile (micro structure). The assessment regarding the effectiveness of a product is always based on the comparison of wrinkle information obtained at defined points in time. Actual subject of the examination is the condition of the wrinkle before the product has been applied for the first time (T0) as well as its state after a course of several applications (T1, T2, T3 …). The analysis of the vertical amplitude of the wrinkles is evaluated alongside the wrinkle flow by making use of the statistic roughness parameters Ra, Rz, and LR known from the 2D analysis. In addition, the 3D roughness parameters such as St, Sa or Sq are being calculated. This is then followed by the evaluation of further characteristic wrinkle features by calculation of their respective surface, volume, amplitude, average and maximum height as well as a final assessment of the product effectiveness for the given examination period. Conclusion The breuckmann dermaTOP allows for the easy, fast and precise analysis of crow’s feet, thereby helping to achieve a scientifically substantiated, objective assessment of the products used for wrinkle reduction. In particular in connection with agents used in skincare products, such as anti-ageing creams, but also in the context of cosmetic treatments, the respective effectiveness results can be reproducibly registered and verified in long term studies, for example by the Institute Dr. Schrader which regularly conducts product verifications for the Stiftung Warentest, a German independent consumer foundation for impartial tests of products and services. Evaluation of the wrinkle amplitude with aid of statistical roughness parameter Contact / Link Position control of the relevant analysis field (above) and extracted 3D mikro skin relief of the wrinkle / the analysis field shown above (below) EOTech SA, 91460 Marcoussis, France www.eotech.fr We would like to thank our sales partner EOTech SA for their kind contribution of the interesting information material and pictures used to compile this report. AICON 3D Systems GmbH Biberweg 30 C | D-38114 Braunschweig tel. +49 (0)531 58 000 58 www.aicon3d.de | info@aicon.de
Similar documents
DermaTOP-HE
The complete solution comes with our VisioTOP-300 bench designed for reproducible positioning and re-positioning of the panellists. The DermaTOP-HE system uses different sets of lenses to adapt the...
More information