FlowBar Catalog Section
Transcription
FlowBar Catalog Section
flowbar open ceiling C Redefine your comfort zone. ™ | www.titus-hvac.com woodgrains metric sizes Redefine your comfort zone™ | www.titus-hvac.com Table of Contents C flowbar flowbar products FlowBar Products.................................................................................................................................................................................. C2 overview Overview........................................................................................................................................................................................ C6 Application Icons Key.................................................................................................................................................................... C6 flowbar linear HighThrow..................................................................................................................................................................................... C9 JetThrow..................................................................................................................................................................................... C10 FlowBar Installations................................................................................................................................................................... C11 Hard Ceiling Applications............................................................................................................................................................ C12 Side Wall Applications................................................................................................................................................................ C14 Acoustical Ceiling Applications................................................................................................................................................... C15 Installation Methods................................................................................................................................................................... C16 Border Types................................................................................................................................................................................ C17 Two-Slot Options................................................................................................................................................................. C17 End Fabrication............................................................................................................................................................................ C18 FL-TZ............................................................................................................................................................................................ C19 flowbar accessories Optional Mitered Corner..................................................................................................................................................... C21 Optional Flow Cross............................................................................................................................................................ C22 Optional Field Cut Spacer Kit.............................................................................................................................................. C22 Optional Blank-Off............................................................................................................................................................... C23 Optional Return Hood/Light Shield..................................................................................................................................... C23 Model FBP or FBPI Plenum for Flowbar Linear Diffusers, Border Types 11, 14, 16, 22, 55, 66......................................... C24 Model FBP or FBPI Plenum for Flowbar Linear Diffusers, Border Type 77 Only................................................................. C24 mounting hardware, installation and details FLOWBAR UHC - Upper Hanger Clip.................................................................................................................................................... C26 USH - Upper Support Hanger.............................................................................................................................................. C26 H1 - Hard Ceiling Clip.......................................................................................................................................................... C26 H2 - Hard Ceiling Clip.......................................................................................................................................................... C27 H3 - Hard Ceiling Clip.......................................................................................................................................................... C27 H4 - Hard Ceiling Clip.......................................................................................................................................................... C27 H5 - Hard Ceiling Clip.......................................................................................................................................................... C27 WC2 - Wall Clip................................................................................................................................................................... C28 WC4 - Wall Clip................................................................................................................................................................... C28 Spline Support Clip (field formed)....................................................................................................................................... C29 Narrow Tee Support Clip..................................................................................................................................................... C29 C2 moduflow ModuFlow................................................................................................................................................................................... C30 Field Installation of Center Tile for Models MF-10, MFI-10, MFB-10, and MFBI-10.................................................................. C31 Center Panel Ceiling Tile Cutting Dimensions.................................................................................................................... C31 Discharge Patterns.............................................................................................................................................................. C31 Field Installation of Center Tile for Models MFR-10 and MFRB................................................................................................. C32 Center Panel Ceiling Tile Cutting Dimensions.................................................................................................................... C32 Return Airflow..................................................................................................................................................................... C32 ModuFlow Applications.............................................................................................................................................................. C33 Table of Contents (continued) flowbar FlowTee....................................................................................................................................................................................... C34 FlowTee Application for Standard Models.................................................................................................................................. C35 FlowTee Application for Bolt-slot Models................................................................................................................................... C35 Typical FlowTee Applications...................................................................................................................................................... C35 FlowTee Dimensional Data.......................................................................................................................................................... C35 performance data FL-10 / FL-15 / FL-20 / FL-25 / FL-30 with Continuous Slot Plenum & HighThrow Pattern Controller........................................ C36 FL-10 / FL-15 / FT-10 / FT-15 - 1-Slot, HighThrow with Titus Plenum......................................................................................... C37 FL-20 / FL-25 / FT-20 - 1 Slot, HighThrow with Titus Plenum..................................................................................................... C38 FL-30 - 1 Slot, HighThrow with Titus Plenum............................................................................................................................. C39 FL-10 / FL-15 / FT-10 / FT-15 - 2-Slot, HighThrow with Titus Plenum......................................................................................... C40 FL-20 / FL-25 / FT-20 - 2-Slot, HighThrow with Titus Plenum..................................................................................................... C41 FL-30 - 2 Slot, HighThrow with Titus Plenum............................................................................................................................. C42 ModuFlow 24 x 24 inches 1-Slot Data........................................................................................................................................ C43 FL-10 / FL-15 / FL-20 / FL-25 / FL-30 with Continuous Slot Plenum and JetThrow Pattern Controller....................................... C43 FL-10 / FL-15 / FT-10 / FT-15 1-Slot, JetThrow with Titus Plenum............................................................................................. C44 FL-15 / FL-20 / FT-15 / FT-20 1-Slot, JetThrow with Titus Plenum............................................................................................. C45 FL-20 / FL-25 / FT-30 / FT-20 1-Slot, JetThrow with Titus Plenum.............................................................................................. C46 FL-10 / FL-15 / FT-10 / FT-15 2-Slot, JetThrow with Titus Plenum............................................................................................. C47 FL-15 / FL-20 / FT-15 / FT-20 2-Slot, JetThrow with Titus Plenum............................................................................................. C48 FL-20 / FL-25 / FL-30 2-Slot, JetThrow with Titus Plenum......................................................................................................... C49 Redefine your comfort zone™ | www.titus-hvac.com flowtee C FLOWBAR C3 flowbar Redefine your comfort zone™ | www.titus-hvac.com FlowBar Products C flowbar pages: C9-C29 FL-10 / FL-15 / FL-20 / FL-25 / FL-30 / FL-TZ ARCHITECTURAL LINEAR DIFFUSER • • • • • • Single slot, large capacity linear diffuser offers an alternative to multi-slot diffusers 2-slot, NT-style and concealed border styles available Supports and fully integrates with various ceiling systems Available in 12-foot increments and five different slot widths Custom curving available to meet designer’s requirements Heavy wall extruded aluminum construction moduflow pages: C30-C33 MF-10 FLOWBAR ARCHITECTURAL LINEAR DIFFUSER C4 • • • • • • Modular design for interior spaces compliments FlowBar linear diffusers Handles large capacities of air using a single slot Designed so ceiling material can be field cut and inserted in face of diffuser Can be adjusted for horizontal or vertical directional air patterns Includes factory supplied plenum with round inlet connection Heavy wall extruded aluminum construction flowbar FlowBar Products (continued) FT-10 / FT-15 / FT-20 ARCHITECTURAL LINEAR DIFFUSER • • • • • Lay-in modular slot diffuser that compliments linear FlowBar models Designed to fit standard lay-in or narrow tee ceiling grid systems Can be adjusted for horizontal or vertical directional air patterns Includes factory supplied plenum with round inlet connection Heavy wall extruded aluminum construction Redefine your comfort zone™ | www.titus-hvac.com flowtee pages: C34-C35 C FLOWBAR C5 flowbar Redefine your comfort zone™ | www.titus-hvac.com Overview The FlowBarTM architectural linear diffuser system maximizes engineering performance without sacrificing aesthetic considerations for the designer. FlowBar’s outstanding performance allows higher air flows than conventional linear diffusers, with lower noise levels, making it ideal for high profile designs. FlowBar also offers an installation alternative to the conventional linear diffuser. Conventional linear diffusers are supported by the duct system and in most cases are installed after the ceiling system is in place. For complete ceiling integration, the FlowBar system is offered with a large selection of flange styles compatible with various ceiling applications. Our unique clip/hanger support system allows for quick and easy installations. C APPLICATION ICONS KEY Diffuser module sizes are hard metric & inlets are soft. Metric linear and grille products are converted to the nearest ¼” for ordering. Contact us for more information. metric sizes can be used in open ceiling environments mounted directly to the ductwork open ceiling additional finish options available for HVAC products that resemble realistic woodgrains, and adds high-end detail quality to any application FLOWBAR woodgrains C6 The FlowBar system actually supports and becomes an integral part of the ceiling system and is installed along with the ceiling suspension system. Titus FlowBar offers a new concept of air distribution that fully integrates with all ceiling systems. The FlowBar system is available in continuous linear, incremental linear and square configurations. This entire series of diffusers is available with two unique pattern controllers. flowbar Overview (continued) Redefine your comfort zone™ | www.titus-hvac.com FlowBar with T-Bar Ceiling Hanger Clip FlowBar Diffuser Pattern Controller Hanger Wire Unit Spacer Spline Clip Tee (by others) C Spline Clip For other applications, see pages C12 & C13 FLOWBAR C7 Redefine your comfort zone™ | www.titus-hvac.com FlowBar System Overview (continued) FLOWBAR C C8 The HighThrow pattern controller allows air to be directed to the left or right as well as downward when installed in a ceiling system. As air is directed in either direction horizontally, a surface effect is maintained, even at reduced volumes, to provide room air motion without drafts. This, along with its high induction characteristics, makes HighThrow an excellent choice for variable volume systems. The JetThrow pattern controller allows the airstream to be directed to meet required comfort conditions. JetThrow is an excellent choice for high bay applications, perimeter zones requiring vertical projection and for side wall applications requiring extended throw. Both HighThrow and JetThrow pattern controllers can be combined within a single FlowBar system. flowbar ADDITIONAL FEATURES OF THE TITUS FLOWBAR SYSTEM INCLUDE: • Single slot, large capacity linear diffuser offers the designer an alternative to other multi-slot linear diffusers • Supports and fully integrates with various ceiling systems • Reduces costs and installation difficulties associated with conventional linear diffusers • Manufactured entirely from heavy wall extruded aluminum • Available in 6-foot or 12-foot segments • Standard accessories ensure straight and true installations • All FlowBar models are available custom curved to meet designer’s requirements • QuickClip® Mounting option allows installation after hard ceiling is installed flowbar FlowBar Linear • The Titus FlowBar linear system is a continuous slot system which allows the air distribution to become inconspicuous, while fully integrating and complementing the ceiling system and other ceiling components • Several frame styles are available to complement various ceiling types. The FlowBar system supports and is directly connected to the ceiling support components, ensuring straight and true installations. • The FlowBar system is installed during the ceiling installation with unique clip and hanger support systems • Standard slot sizes are 1, 1½, 2, 2½ and 3 inches. Section lengths up to 12 feet are standard to minimize joints in long runs. • All FlowBar linear systems are available curved FLOWBAR - HIGHTHROW • Integral pattern controllers are on standard 24" centers, allowing the airstream to be directed left and right for horizontal and vertical airflow Redefine your comfort zone™ | www.titus-hvac.com FL - HighThrow / FL-TZ • Mitered corners, mitered tees and butt ends are available • Standard finish is flat black for interior surfaces exposed to view and white for exposed flanges, with optional anodized finishes and custom colors available open ceiling metric sizes See website for Specifications AVAILABLE MODELS: FL-10-HT / 1” Slot / HighThrow Option FL-15-HT / 1½” Slot / HighThrow Option FL-20-HT / 2” Slot / HighThrow Option FL-25-HT / 2½” Slot / HighThrow Option FL-30-HT / 3” Slot / HighThrow Option FL-TZ / 1" Slot woodgrains C HighThrow Series Adjustable Controller FINISHES Standard Finish - #26 White Border (Black pattern controllers) Optional Finish - Optional & anodized finishes available Note: Border 22 and 55 are finished in #84 Black Titus FlowBar architectural linear diffuser system maximizes engineering performance without sacrificing aesthetic considerations for the designer. FlowBar’s outstanding performance allows higher airflows than conventional linear diffusers. The wide array of slot widths allow for more CFM per linear foot while minimizing noise and pressure loss. The Flowbar system is available in continuous linear, incremental linear and square configurations. ADVANTAGES • Integral pattern controllers are on standard 24" centers, allowing the airstream to be directed left and right for horizontal and vertical airflow • FlowBar system allows supply, return and exhaust air all from one diffuser, reducing ceiling clutter • FlowBar systems satisfy both the architect's and engineer's requirements for designing an air distribution system that will maintain optimum room air conditions while being inconspicuous to the viewer FL - HIGHTHROW / FL-TZ OVERVIEW C9 flowbar Redefine your comfort zone™ | www.titus-hvac.com FlowBar Linear (continued) FL - JetThrow / FL-TZ • This series is identical to the HighThrow series except for the pattern controllers • JetThrow with nonadjustable pattern controllers is also available for curved FlowBar applications • JetThrow pattern controllers are manufactured using only heavy wall extruded aluminum • Standard finish is a white face with a flat black interior. Anodized finishes and custom colors are available. FLOWBAR - JETTHROW C woodgrains metric sizes See website for Specifications AVAILABLE MODELS: FL-10-JT / 1” Slot / JetThrow Option FL-15-JT / 1½” Slot / JetThrow Option FL-20-JT / 2” Slot / JetThrow Option FL-25-JT / 2½” Slot / JetThrow Option FL-30-JT / 3” Slot / JetThrow Option FL-TZ / 1" Slot open ceiling JetThrow Series Adjustable Controller FINISHES FL - JETTHROW / FL-TZ Standard Finish - #26 White Border (Black pattern controllers) Optional Finish - Optional & anodized finishes available Note: Border 22 and 55 are finished in #84 Black C10 OVERVIEW Titus FlowBar architectural linear diffuser system maximizes engineering performance without sacrificing aesthetic considerations for the designer. FlowBar’s outstanding performance allows higher airflows than conventional linear diffusers. The wide array of slot widths allow for more CFM per linear foot while minimizing noise and pressure loss. The Flowbar system is available in continuous linear, incremental linear and square configurations. ADVANTAGES • The optional JetThrow pattern controllers allow the airstream to be jetted in a vertical direction when installed in a ceiling and horizontal when installed in a side wall application. The pattern controllers also allow the airstream to be directed left or right when in a ceiling application, and up or down when in a side wall application. • JetThrow pattern controllers are an excellent choice where extended throw is required as in high bay applications for heated and/or cooled air. This product is also useful along perimeter walls where heated air can be directed downward, terminating at the floor at a comfortable velocity. • JetThrow pattern controllers can be alternated with the standard HighThrow pattern controllers. For cold climate applications, heated air can be directed to the floor while colled air is directed horizontally across the ceiling, all from the same FlowBar. FLOWBAR INSTALLATIONS The FlowBar system, with the exception of Border 77, is installed during the ceiling installation with unique mounting clips. Border 77 is installed after the drywall is in place. Available in up to 12-foot lengths, FlowBar is straighter and often less expensive to install than conventional linear diffusers. Redefine your comfort zone™ | www.titus-hvac.com FlowBar is designed to fully integrate into the ceiling system. flowbar C INSTALLATIONS C11 flowbar Redefine your comfort zone™ | www.titus-hvac.com HARD CEILING APPLICATIONS CEILING FRAMING SPLINE CLIP (SS1) GYP BOARD HARD CEILING (H2) CLIP GYP BOARD Ceiling / Ceiling - Border 66 Ceiling / Ceiling - Border 26 HARD CEILING (H2) CLIP CEILING FRAMING Ceiling/Ceiling - Border 26 CEILING FRAMING CEILING FRAMING Ceiling/Ceiling - Border 66 HARD CEILING (H2) CLIP GYP BOARD TRIM SPACKLE CEILING FRAMING HARD CEILING (H2) CLIP TRIM GYP BOARD GYP BOARD SPACKLE SPACKLE SPACKLE GYP BOARD Ceiling / Ceiling - Border 11 Ceiling/Ceiling Reveal - Border 11 CEILING FRAMING CEILING FRAMING 5/8" GYP BOARD CEILING FRAMING Ceiling/Ceiling Reveal - Border 11 HARD CEILING (H2) CLIP HARD CEILING (H5) CLIP HARD CEILING (H3) CLIP HARD CEILING APPLICATIONS CEILING FRAMING CEILING TILE TAPE AND SPACKLE Ceiling / Ceiling Reveal - Border 11 HARD CEILING (H3) CLIP 1/2" GYP BOARD TAPE AND SPACKLE TAPE AND SPACKLE Ceiling / Ceiling - Border 22 GYP BOARD SPACKLE SPACKLE Ceiling / Ceiling - Border 55 Ceiling/Ceiling - Border 55 Ceiling/Ceiling - Border 22 FASTENER BRACKET GYP BOARD QuickClip® Mounting Ceiling / Ceiling - Border 77 C12 HARD CEILING (H4) CLIP HARD CEILING (H4) CLIP CEILING FRAMING GYP BOARD CEILING FRAMING C TEE HARD CEILING (H3) CLIP Items in italics are supplied by Titus Items not italicized are supplied by others GYP BOARD flowbar Hard Ceiling Applications (continued) C C WALL FRAMING GYP BOARD CEILING FRAMING UPPER HANGER CLIP (UHC) CEILING FRAMING WALL CLIP (WC2) WALL FRAMING GYP BOARD POCKET (BY OTHERS) UPPER HANGER CLIP (UHC) GYP BOARD AVAILABLE RETURN AIR GYP BOARD Ceiling / Wall Reveal - Border 66 UPPER HANGER CLIP (UHC) Ceiling / Wall Reveal - Border 66 WALL FRAMING WALL FRAMING GYP BOARD POCKET (BY OTHERS) GYP BOARD CEILING FRAMING CEILING FRAMING GYP BOARD AVAILABLE RETURN AIR ROLLED SHADE HARD CEILING (H1) CLIP WALL CLIP (WC4) C GYP BOARD Ceiling / Wall Pocket - Border 66 Ceiling / Wall - Border 66 WALL FRAMING Ceiling/Ceiling Reveal - Border 66 HARD CEILING (H3) CLIP CEILING FRAMING HARD CEILING (H4) CLIP GYP BOARD CEILING FRAMING Redefine your comfort zone™ | www.titus-hvac.com C C WALL CEILING (WC2) CLIP CEILING FRAMING HARD CEILING (H3) CLIP TRIM GYP BOARD GYP BOARD Ceiling / Wall - Border 14 Ceiling / Offset - Border 14 Ceiling/Wall - Border 14 Ceiling/Ceiling Reveal - Border 14 Items in italics are supplied by Titus. Items not italicized are supplied by others. WALL FRAMING HARD CEILING APPLICATIONS GYP BOARD C13 flowbar Redefine your comfort zone™ | www.titus-hvac.com SIDE WALL APPLICATIONS GYP BOARD HARD CEILING (H3) CLIP TAPE AND SPACKLE GYP BOARD TAPE AND SPACKLE SIDE WALL APPLICATIONS C C14 HARD CEILING (H3) CLIP Side Wall - Exposed Flange - Border 66 Side Wall - Hidden Flange - Border 22 Side Wall - Hidden Flange - Border 22 Side Wall - Hidden Flange - Border 11 A A A ACOUSTICAL CEILING APPLICATIONS TEE SPLINE CLIP (SS1) TEE SPLINE CLIP(SS1) SPLINE TEE CLIP (SS1) GYP BOARD HANGER CLIP (UHC) Redefine your comfort zone™ | www.titus-hvac.com HANGER CLIP (UHC) flowbar A WALL FRAMING WALL CLIP (WC2) CEILING TILE AVAILABLE RETURN AIR CEILING TILE CEILING ATILEA Ceiling / Ceiling - Border 66 CeilingA / Wall - Border 66 A GYP BOARD SPLINE TEE CLIP (SS1) HANGER CLIP (UHC) WALL FRAMING WALL CLIP (WC4) TEE CEILING TILE CEILING TILE Ceiling / Wall Reveal - Border 66 HANGER CLIP (UHC) CEILING TILE Ceiling / Wall Pocket - Border 66 GYP BOARD WALL FRAMING POCKET (BY OTHERS) C AVAILABLE RETURN AIR Ceiling / Wall Pocket - Border 66 POCKET (BY OTHERS) GYP BOARD ROLLED SHADE WALL FRAMING SPLINE CLIP (SS1) TEE GYP BOARD HANGER CLIP (UHC) CEILING TILE Ceiling / Ceiling / Pocket - Border 66 Items in italics are supplied by Titus Items not italicized are supplied by others POCKET (BY OTHERS) CEILING TILE AVAILABLE RETURN AIR WALL FRAMING ACOUSTICAL CEILING APPLICATIONS TEE SPLINE CLIP (SS1) SPLINE CLIP (SS1) HANGER CLIP (UHC) C15 flowbar Redefine your comfort zone™ | www.titus-hvac.com INSTALLATION METHODS Frame Opening Width (W) From Table Plus 1/2” Frame Frame Hard Ceiling Clip HI, H2, H3 or H4 10" Maximum Centers C Spline Support Clip SS1 Mounting Screws HANGER WIRE Refer to Titus FlowBar IOM for additional installation details PATTERN CONTROLLER INSTALLATION METHODS FLOWBAR DIFFUSER C16 UPPER HANGER CLIP (UHC) TEE SPLINE CLIP (SS1) SPLINE CLIP (SS1) UNIT SPACER Refer to Titus FlowBar IOM for additional installation details Items in italics are supplied by Titus Items not italicized are supplied by others flowbar BORDER TYPES W W H H H H C Border Type 11 S D ½ A S A C S D C Border Type 22 S D Border Type 66 Border Type 26 Border Type 26 W 1 11/16 1 11/16 H 2 5/16 2 5/16 A A Border Type 77 S W W S D S A A A Border Type 14* Border Type 16 Border Type 77 (Concealed Fastening) uses Border Type 66 extrusions and adds a mounting bracket, a #10 x 2½" screw and a hole in the spreader Model Redefine your comfort zone™ | www.titus-hvac.com W W Border Type 55 S Slot W Width Width A Border Width C Border Width D Border Width H Height ⁄8 15⁄8 13⁄8 111⁄16 FL-10 1 2¾ FL-15 1½ 3¾ 11⁄8 17⁄8 15⁄8 111⁄16 FL-20 2 4¾ 13⁄8 21⁄8 17⁄8 111⁄16 FL-25 2½ 5¾ 5 1 ⁄8 1 2 ⁄8 1 2 ⁄8 25⁄16 FL-30 3 6¾ 17⁄8 23⁄8 23⁄8 25⁄16 7 C Dimensions are in inches * One-way blow only 2CRN 2CRB WN W S S S B 1-Slot FL-10 3 FL-15 2-Slot 2-Slot 2CRA & 2 CRB 2CRN 5½ 63⁄8 4 7½ 83⁄8 FL-20 5 9½ 103⁄8 FL-25 6 11½ 123⁄8 FL-30 7 13½ 143⁄8 2CRA Model W S S B S 9/16 Note: Not all border options are shown. For other border options, contact your Titus sales representative. For typical border applications see pages C12-C15. S Slot B Border W Width Width Width WN Width FL-10 1 17⁄16 53⁄16 61⁄16 FL-15 1½ 115⁄16 73⁄16 81⁄16 FL-20 2 27⁄16 93⁄16 101⁄16 FL-25 2½ 15 2 ⁄16 3 11 ⁄16 121⁄16 FL-30 3 37⁄16 133⁄16 141⁄16 BORDER TYPES TWO-SLOT OPTIONS Ceiling Opening Width for Border Type 77 FlowBar Model C17 flowbar Redefine your comfort zone™ | www.titus-hvac.com END FABRICATION C D O C D C D C D O O C D C D O SX Straight C Border Type 11 22/55 END FABRICATION 66/77 14 16 Slot Width 1 1½ 2 2½ 3 1 1½ 2 2½ 3 1 1½ 2 2½ 3 1 1½ 2 2½ 3 1 1½ 2 2½ 3 C D+3⁄8 D+3⁄8 D+3⁄8 D+3⁄8 D+3⁄8 NA NA NA NA NA D+3⁄8 D+3⁄8 D+3⁄8 D+3⁄8 D+3⁄8 NA NA NA NA NA D+3⁄8 D+3⁄8 D+3⁄8 D+3⁄8 D+3⁄8 Note: (NA) indicates not available Dimensions in inches D = ordered or specified length C18 O O ECX End Cap Y Open End SXX O D+21⁄8 D+21⁄8 D+21⁄8 D+21⁄8 D+21⁄8 NA NA NA NA NA D+21⁄8 D+21⁄8 D+21⁄8 D+21⁄8 D+21⁄8 NA NA NA NA NA D+21⁄8 D+21⁄8 D+21⁄8 D+21⁄8 D+21⁄8 C D+3⁄16 D+3⁄16 D+3⁄16 D+3⁄16 D+3⁄16 NA NA NA NA NA D+3⁄16 D+3⁄16 D+3⁄16 D+3⁄16 D+3⁄16 NA NA NA NA NA D+3⁄16 D+3⁄16 D+3⁄16 D+3⁄16 D+3⁄16 SXY O D+11⁄16 D+11⁄16 D+11⁄16 D+11⁄16 D+11⁄16 NA NA NA NA NA D+11⁄16 D+11⁄16 D+11⁄16 D+11⁄16 D+11⁄16 NA NA NA NA NA D+11⁄16 D+11⁄16 D+11⁄16 D+11⁄16 D+11⁄16 C D D D D D D D D D D D D D D D D D D D D D D D D D YY O D D D D D D D D D D D D D D D D D D D D D D D D D C D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 ECXX O D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 D+1⁄8 C D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 ECXY O D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 D+1⁄16 flowbar DIMENSIONS FL-TZ 4" WIDTH HT PATTERN CONTROLLER FL-TZ 4" WIDTH JT PATTERN CONTROLLER 3 7/8" 2 3/4" 3 7/8" 2 3/4" 5/16" 1 3/16" 1" 3 3/8" 1 3/16" 5/16" 1" 3 3/8" 1/4" 1/4" FL-TZ 6" WIDTH JT PATTERN CONTROLLER FL-TZ 6" WIDTH HT PATTERN CONTROLLER C 5 7/8" 5 7/8" 5 3/16" 5 3/16" 5/16" 31/32" 1" Redefine your comfort zone™ | www.titus-hvac.com FL-TZ UNIT DIMENSIONS 5/16" 31/32" 1 7/16" 5 3/8" 1" 1 7/16" 1/4" 5 3/8" 1/4" END FABRICATION AND LENGTH O D FL-TZ-DF / -NT D O D O 24 23¾ 237⁄8 23¼ 233⁄8 30 29¾ 29 ⁄8 29¼ 293⁄8 36 35¾ 357⁄8 35¼ 353⁄8 48 47¾ 477⁄8 47¼ 473⁄8 60 59¾ 59 ⁄8 59¼ 593⁄8 72 71¾ 717⁄8 71¼ 713⁄8 7 7 DIMENSIONS END CAP IS STANDARD FL-TZ-LT Nominal Module Length C19 flowbar Redefine your comfort zone™ | www.titus-hvac.com DIMENSIONS FL-TZ UNIT DIMENSIONS NOMINAL MODULE LENGTH O = OVERALL D END CAP BOTH SIDES FL-TZ-LT 15/16" STANDARD TEE 13/32" OVERLAP TYP NOMINAL MODULE LENGTH C D END CAP BOTH SIDES O = OVERALL FL-TZ-DF 9/16" NARROW TEE (DROP FACE REVEAL) 1/32" GAP TYP NOMINAL MODULE LENGTH END CAP BOTH SIDES DIMENSIONS FL-TZ-NT 9/16" NARROW TEE (BOLT SLOT) C20 D O = OVERALL 1/32" GAP TYP flowbar ACCESSORIES OPTIONAL MITERED CORNER FBMC-10 / 1” Slot FBMC-15 / 1½” Slot FBMC-20 / 2” Slot FBMC-25 / 2½” Slot FBMC-30 / 3” Slot • Optional Mitered Corners are rendered inactive with factory installed blank-offs • End Caps, End Borders, Mitered Corners and Blank-Offs are optional • FlowBar Diffusers can be joined together end-to-end to form long continuous runs • Spline Clips (SS1) maintain tight joints between sections • Optional End Borders and End Caps close off the ends of the diffusers and simplify installations ending at walls and other stopping points Border Type 11 Number Slot of Slots Width 1 2 Border Type 66 Border Type 22 Face View L W A L W A L W A 1 8¾ 2¾ 6 9¼ 3¾ 5½ 9½ 4¼ 5¼ 1½ 9¾ 3¾ 6 10¼ 4¾ 5½ 10½ 5¼ 5¼ 2 10¾ 4¾ 6 11¼ 5¾ 5½ 11½ 6¼ 5¼ 2½ 11¾ 5¾ 6 12¼ 6¾ 5½ 12¼ 6¾ 5½ 3 12¾ 6¾ 6 13¼ 7¾ 5½ 13¼ 7¾ 5½ 1 113⁄16 53⁄16 6 1111⁄16 63⁄16 5½ N/A N/A N/A 1½ 3 13 ⁄16 3 7 ⁄16 6 11 13 ⁄16 11 8 ⁄16 5½ N/A N/A N/A 2 153⁄16 93⁄16 6 1511⁄16 1011⁄16 5½ N/A N/A N/A 2½ 173⁄16 113⁄16 6 1711⁄16 1211⁄16 5½ N/A N/A N/A 3 19 ⁄16 13 ⁄16 6 19 ⁄16 14 ⁄16 5½ N/A N/A N/A 3 3 11 11 Redefine your comfort zone™ | www.titus-hvac.com FBMC L W A C Top View End Cap and Mitered Corner Installation Mitered Corner Spacer Pattern Controller Blank-off Straight End Border (Note) Spline Support Clip ACCESSORIES End Cap Note: Optional Straight End Borders not available for Border Types 22, 14 and 55 C21 flowbar Redefine your comfort zone™ | www.titus-hvac.com ACCESSORIES FBC OPTIONAL FLOW CROSS FBC-10 / 1” Slot FBC-15 / 1½” Slot FBC-20 / 2” Slot FBC-25 / 2½” Slot FBC-30 / 3” Slot Number of Slot Slots Width 1 L Border Type 11 Border Type 66 W A W A 1 14¾ 2¾ 6 3¾ 5½ 1½ 15¾ 3¾ 6 4¾ 5½ 2 16¾ 4¾ 6 5¾ 5½ 2½ 17¾ 5¾ 6 6¾ 5½ 3 18¾ 6¾ 6 7¾ 5½ All dimensions are in inches Not available in 2 slots C Face View L A Top View W HTSK / JTSK OPTIONAL FIELD CUT SPACER KIT ACCESSORIES C22 1.Determine the desired length and cut accordingly HTSK-10 / 1” Slot HTSK-15 / 1½” Slot HTSK-20 / 2” Slot HTSK-25 / 2½” Slot HTSK-30 / 3” Slot JTSK-10 / 1” Slot JTSK-15 / 1½” Slot JTSK-20 / 2” Slot JTSK-25 / 2½” Slot JTSK-30 / 3” Slot 2.Insert the optional field cut spacer kit 3.Place the spacer kit ¼ inch from the newly trimmed end Sometimes the exact length of a FlowBar diffuser is not known until the diffuser is being installed. Standard FlowBar diffusers can be field trimmed. Use the following information to trim FlowBar in the field. Note: The pattern controller must be cut 1¼ inches shorter than the borders to accommodate the Field Spacer Kit The following figures illustrate the trimming procedure. Step 1 Step STEP 2 2 STEP 1 FIELD CUT SPACER KIT CUT Step 3 STEP 3 1/4" flowbar ACCESSORIES FBBO Blank-Off Optional Blank-off (Painted Flat Black) OPTIONAL BLANK-OFF FBBO-10 / 1” Slot FBBO-15 / 1½” Slot FBBO-20 / 2” Slot FBBO-25 / 2½” Slot FBBO-30 / 3” Slot Note: Units ship in 6 foot increments. Field cut for shorter length. FBR Uninsulated Return Hood/Light Shield OPTIONAL RETURN HOOD/LIGHT SHIELD FBR-10 / 1” Slot FBR-15 / 1½” Slot FBR-20 / 2” Slot FBR-25 / 2½” Slot FBR-30 / 3” Slot H C Note: Return Hoods are 51 percent free area perforated galvanized steel, painted flat black FBRI Redefine your comfort zone™ | www.titus-hvac.com FBBO Insulated Return Hood/Light Shield FBRI-10 / 1” Slot FBRI-15 / 1½” Slot FBRI-20 / 2” Slot FBRI-25 / 2½” Slot FBRI-30 / 3” Slot Insulation Note: Return Hoods are 51 percent free area perforated galvanized steel, painted flat black 2½" Units ship in 4 foot increments. Field cut for shorter lengths. Return Hoods not available on curved FlowBar 1 2 1 33⁄8 11⁄2 33⁄8 2 33⁄8 21⁄2 71/16 3 71/16 1 21⁄8 11⁄2 31⁄8 2 41⁄8 21⁄2 51⁄8 3 61⁄8 ACCESSORIES Number of Slot H (Height) Slots Width All dimensions are in inches C23 flowbar Redefine your comfort zone™ | www.titus-hvac.com ACCESSORIES FBP/ FBPI MODEL FBP OR FBPI PLENUM FOR FLOWBAR LINEAR DIFFUSERS, BORDER TYPES 11, 14, 16, 22, 55, 66 Nominal Length W Plenum Length 1¼" FBP-10 / 1” Slot FBP-15 / 1½” Slot FBP-20 / 2” Slot FBP-25 / 2½” Slot FBP-30 / 3” Slot FBPI-10* / 1” Insulated FBPI-15* / 1½” Insulated FBPI-20* / 2” Insulated FBPI-25* / 2½” Insulated FBPI-30* / 3” Insulated A 10" B *Note: End Caps are not insulated Border 11, 14, 16, 22, 55, 66 W (Width) FlowBar Unit C FBP & FBPI-10 FBP & FBPI-15 FBP & FBPI-20 FBP & FBPI-25 FBP & FBPI-30 Nominal Length Slots 1 2 CRN 2¾ 3¾ 4¾ 5¾ 6¾ 6⅛ 8⅛ 10⅛ 12⅛ 14⅛ Standard Available Inlets 2CRA, 2CRB 5¼ 7¼ 9¼ 11¼ 13¼ MODEL FBP OR FBPI PLENUM FOR FLOWBAR LINEAR DIFFUSERS, BORDER TYPE 77 ONLY Plenum Length (inches) Oval 24, 36, 48, 60 24, 36, 48, 60 24, 36, 48, 60 24, 36, 48, 60 24, 36, 48, 60 6, 8, 10, 12 6, 8, 10, 12 6, 8, 10, 12 6, 8, 10, 12 6, 8, 10, 12 21¾, 33¾, 45¾, 57¾ 21¾, 33¾, 45¾, 57¾ 21¾, 33¾, 45¾, 57¾ 21¾, 33¾, 45¾, 57¾ 21¾, 33¾, 45¾, 57¾ Standard Inlet Size Dimensions A B 6 Oval 6¼ 5¼ 8 Oval 3 9 /8 5¼ 10 Oval 12½ 5¼ 12 Oval 14 /8 77/8 1 Nominal Length W Plenum Length 1¼" ACCESSORIES C24 FBP-10 / 1” Slot FBP-15 / 1½” Slot FBP-20 / 2” Slot FBP-25 / 2½” Slot FBP-30 / 3” Slot FBPI-10* / 1” Insulated FBPI-15* / 1½” Insulated FBPI-20* / 2” Insulated FBPI-25* / 2½” Insulated FBPI-30* / 3” Insulated A B 11" FlowBar Border 77 Installation Detail *Note: End Caps are not insulated Border 77 W (Width) FlowBar Unit FBP & FBPI-10 FBP & FBPI-15 FBP & FBPI-20 FBP & FBPI-25 FBP & FBPI-30 Nominal Length Slots 1 2 CRN 3¾ 4¾ 5¾ 6¾ 7¾ 71/16 91/16 111/16 131/16 151/16 2CRA, 2CRB 6 3/16 8 3/16 10 3/16 12 3/16 14 3/16 Standard Available Inlets Plenum Length (inches) Oval 24, 36, 48, 60 24, 36, 48, 60 24, 36, 48, 60 24, 36, 48, 60 24, 36, 48, 60 6, 8, 10, 12 6, 8, 10, 12 6, 8, 10, 12 6, 8, 10, 12 6, 8, 10, 12 All dimensions are in inches 24, 36, 48, 60 24, 36, 48, 60 24, 36, 48, 60 24, 36, 48, 60 24, 36, 48, 60 Standard Inlet Size Dimensions A B 6 Oval 6¼ 5¼ 8 Oval 93/8 5¼ 10 Oval 12½ 5¼ 12 Oval 141/8 77/8 flowbar MOUNTING HARDWARE INSTALLATION AND DETAILS USH H1 Upper Hanger Clip Upper Support Hanger Hard Ceiling Clip Redefine your comfort zone™ | www.titus-hvac.com UHC C H3 H4 Hard Ceiling Clip Hard Ceiling Clip Hard Ceiling Clip WC2 WC3 WC4 Wall Clip Wall Clip Wall Clip MOUNTING, INSTALLATION AND DETAILS H2 C25 flowbar Redefine your comfort zone™ | www.titus-hvac.com Mounting Hardware Installation and Details (continued) UHC - UPPER HANGER CLIP The UHC - Hanger Clip is used to suspend the FlowBar assembly from the structure. The clip is designed to utilize standard ceiling hanger wire. UHC is for 1-slot only and FL-10, 15, 20. 1" UHC 115/16" USH - UPPER SUPPORT HANGER C The USH - Support Hanger is used to suspend one side of the FlowBar assembly from the structure. The hanger is designed to utilize standard ceiling hanger wire. Use the USH clip for FL-25 and 30 and all 2-slot units. USH 111/16" MOUNTING, INSTALLATION & DETAILS 5/8" C26 ¼" 2" H1 - HARD CEILING CLIP The H1 - Hard Ceiling Clip is used to mount the FlowBar assembly with border type(s) 66 or 16, when a standard 5/8" gyp board ceiling is required. 5/8" ¼" 2" 1¼" H1 flowbar Mounting Hardware Installation and Details (continued) 5/8" 5/16" 2" 1¼" H2 H3 - HARD CEILING CLIP Redefine your comfort zone™ | www.titus-hvac.com H2 - HARD CEILING CLIP The H2 - Hard Ceiling Clip is used to mount the FlowBar assembly with border type(s) 11 or 16, when a standard 5/8" gyp board ceiling is required. The H3 - Hard Ceiling Clip can be used to mount the FlowBar assembly with border types 22 and 14 when a standard 5/8" gyp board ceiling is required. 5/8" 2" 17/16" C 15/16" H3 The H4 - Hard Ceiling Clip is used to mount the FlowBar assembly with border type(s) 66 or 16, when a standard 5/8" gyp board ceiling is required. 5/8" 2" 19/16" H4 17/16" H5 - HARD CEILING CLIP The H5 - Hard Ceiling Clip is used to mount FL10, 15 or 20 border 22 to ½" gyp board. 5/8" 2" 17/16" H5 MOUNTING, INSTALLATION AND DETAILS H4 - HARD CEILING CLIP 11/16" C27 flowbar Redefine your comfort zone™ | www.titus-hvac.com Mounting Hardware Installation and Details (continued) WC2 - WALL CLIP The WC2 - Wall Clip is used to mount the FlowBar assembly with border type(s) 11, 66 or 16 away from a wall when a reveal is required. The wall reveal can be used as a return air slot. WC2 111/16" 5/8" 2" 17/16" WC3 - WALL CLIP The WC3 - Wall Clip is used to flush mount the FlowBar assembly, with border type 11 to a wall. WC3 C 15/16" 1¼" 3/8" 2" 7/16" MOUNTING, INSTALLATION & DETAILS WC4 - WALL CLIP C28 The WC4 - Wall Clip is used to flush mount the FlowBar assembly, with border types 16 or 66 to a wall. WC4 9/16" 5/8" 111/16" 2" flowbar Mounting Hardware Installation and Details (continued) 5 /8" 3" 3" SS1 SPLINE SUPPORT CLIP (AS SHIPPED) The SS1 - Spline Clip is also used to adjoin multiple sections of FlowBar when continuous lengths are desired. 5 Redefine your comfort zone™ | www.titus-hvac.com SPLINE SUPPORT CLIP (FIELD FORMED) The SS1 - Spline Clip is used to attach drop ceiling “tees” to the FlowBar assembly. /8" C 6" SS1 NARROW TEE SUPPORT CLIP The SC1 - Support Clip is used to support the Narrow Tee assembly with border type 11 suspension systems. 2" 5 ¼" Border Type 1-Slot FlowBar 2-Slot FlowBar 11 H2, WC2, WC3, USH, UHC, SC1 H2, WC2, WC3, USH, SC1 14 H3, H4, USH, UHC N/A 22, 55 H3, H4, H5, USH, UHC H3, H4, H5 66, 77 H1, WC2, WC4, UHC H1, WC2, WC4, USH 16 H1, H2, WC2, WC4, UHC, USH, SC1 H1, WC2, WC4, USH 55 H3, H4, H5, USH, UHC N/A /8" MOUNTING, INSTALLATION AND DETAILS SC1 C29 Redefine your comfort zone™ | www.titus-hvac.com ModuFlow Series flowbar ModuFlow • The ModuFlow series is an excellent choice for interior spaces requiring a visually pleasing single slot, high performance diffuser. The ModuFlow diffusers are designed to complement the Titus FlowBar linear diffuser system. • One of the exciting features of the ModuFlow diffuser is that it is engineered to handle large capacities of air using a single slot • To fully integrate into the ceiling system, the ModuFlow diffuser is designed so the ceiling material can be field cut and inserted in the face of the diffuser. This allows the architect the opportunity to blend the air distribution system into the ceiling design. The ModuFlow diffuser can be field adjusted for one, two, three, or four-way directional air patterns. This adjustability gives the designer the flexibility to use the diffuser in a wide range of space sizes and configurations. • Material is heavy wall, extruded aluminum MODUFLOW • Standard finish is white face with a flat black interior C AVAILABLE MODELS: MF-10 / 1” Slot MFI-10 / 1” Slot / Insulated MFB-10 / 1” Slot / Bolt-slot MFBI-10 / 1” Slot / Bolt-slot / Insulated MFR-10 / 1” Slot / Return MFRB-10 / 1” Slot / Bolt-slot / Return FINISHES Standard Finish - #26 White Border (Black pattern controllers) Optional Finish - Optional & anodized finishes available OVERVIEW The Titus ModuFlow series is an excellent choice for interior spaces requiring a visually pleasing single slot, high performance diffuser. The ModuFlow diffusers are designed to complement the FlowBar linear diffuser system. MODUFLOW ADVANTAGES C30 • ModuFlow diffusers can be field adjusted for vertical or horizontal directional air patterns. Set for horizontal flow, the diffuser generates a tight air pattern along the ceiling. This air pattern maximizes space, comfort and makes the diffuser an excellent selection for variable volume air systems. • ModuFlow diffusers are designed for lay-in, concealed or hard ceilings. Standard module size is 24 x 24 inches. Standard slot width is 1". Units are shipped with integral plenums and hoods. See website for Specifications flowbar FIELD INSTALLATION OF CENTER TILE FOR MODELS Center Panel Ceiling Tile Cutting Dimensions 237/16" Back pan 237/16" Clips Redefine your comfort zone™ | www.titus-hvac.com MF-10, MFI-10, MFB-10, AND MFBI-10 Ceiling Tile by Others 1¼" Frame and Pattern Controller Assembly 7¼" 6" C Ceiling Tile Cutting Dimensions No. of Slots 1 Slot Width 1” 17 /16” x 17 15/16” 15 Discharge Patterns 2-Way 2-Way Opposite 3-Way 4-Way Note: To create adjustable discharge patterns, optional blank off strips (FBBO) must be used MODUFLOW 1-Way C31 flowbar Redefine your comfort zone™ | www.titus-hvac.com FIELD INSTALLATION OF CENTER TILE FOR MODELS MODELS MFR-10 AND MFRB Center Panel Ceiling Grid Cutting Dimensions 237/16" Light Shield Top View Upper Surface of Light Shield Clips 237/16" Grid by Others 1¼" C ModuFlow Grid Cutting Dimensions No. of Slots 1 Slot Width 1” 17 /16” x 17 15/16” 15 MODUFLOW Return Airflow C32 T-Bar (by others) 7¼" 6" flowbar MODUFLOW APPLICATIONS Plenum Clip Plenum Clip Tee Framing SC1 Clip Ceiling Tile Border Type 16 Narrow Tee Ceiling Tile Gyp Board Hard Ceiling Clip Gyp Board Redefine your comfort zone™ | www.titus-hvac.com ModuFlow Plenum ModuFlow Plenum Border Type 66 Hard Ceiling C MODUFLOW APPLICATIONS Items in italics are supplied by Titus Items not italicized are supplied by others C33 flowbar Redefine your comfort zone™ | www.titus-hvac.com FlowTee System FlowTee • The Titus FlowTee system is a series of lay-in type modular slot diffusers which complement linear FlowBar models. FlowTee diffusers utilize the HighThrow and/or JetThrow pattern controllers. • The FlowTee diffuser’s high induction characteristics make it an excellent choice for interior variable volume system applications where it is important to maintain room air motion when air volumes are reduced • FlowTee diffusers allow the designer to maintain a linear appearance with a lay-in diffuser • Standard module lengths are 24, 48 and 60 inches • Standard slot sizes are 1, 1½ and 2 inches • FlowTee diffusers are manufactured using only heavy wall extruded aluminum FLOWTEE • Standard finish is flat black for interior surfaces exposed to view and white for exposed flanges C AVAILABLE MODELS: FT-10 / 1” Slot FT-15/ 1½” Slot FT-20 / 2” Slot FTI-10 / 1” Slot / Insulated FTI-15 / 1½” Slot / Insulated FTI-20 / 2” Slot / Insulated FTB-10 / 1” Slot / Bolt-slot FTB-15 / 1½” Slot / Bolt-slot FTB-20 / 2” Slot / Bolt-slot FTBI-10 / 1” Slot / Bolt-slot, Insulated FTBI-15 / ½” Slot / Bolt-slot, Insulated FTBI-20 / 2” Slot / Bolt-slot, Insulated FINISHES Standard Finish - #26 White Border (Black pattern controllers) Optional Finish - Optional & anodized finishes available FLOWTEE OVERVIEW C34 The Titus FlowTee system is a series of lay-in type modular slot diffusers which complement linear FlowBar models. The FlowTee diffuser’s high induction characteristics make it an excellent choice for interior variable volume system applications where it is important to maintain room air motion when air volumes are reduced. ADVANTAGES • FlowTee diffusers are available with various frame styles to integrate with most ceiling systems. The FlowTee is designed for standard grid modules. FlowTee bolt-slot is designed to lay flush in the grid. Both are available insulated. See website for Specifications flowbar FLOWTEE APPLICATION FOR STANDARD MODELS W Plenum Length W 1¼" Redefine your comfort zone™ | www.titus-hvac.com Shown below in 1- and 2- slot applications utilizing Border Type 66 1¼" 111/16" Unit Length Nominal Length FLOWTEE APPLICATION FOR BOLT-SLOT MODELS Shown below in 1- and 2- slot applications utilizing Border Type 11 W W 1¼" Plenum Length 1¼" C 111/16" Unit Length Nominal Length Bolt-slot TYPICAL FLOWTEE APPLICATIONS W (Width) Slots FlowTee Model 1 2CRN 2CRA, 2CRB FT, FTB-10 23/4 61/16 53/16 FT, FTB-15 3 3 /4 8 /16 FT, FTB-20 43/4 FTI, FTBI-10 Nominal Length Available Inlets (inches) Plenum Length (inches) Oval Standard 24, 48, 60 6, 8, 10, 12 7 /16 24, 48, 60 101/16 93/16 23/4 61/16 FTI, FTBI-15 3 3 /4 FTI, FTBI-20 43/4 Unit Length (inches) Bolt-Slot Standard 213/4, 453/4, 573/4 213/8, 453/8 235/8, 475/8, 595/8 237/16, 477/16 6, 8, 10, 12 21 /4, 45 /4, 57 /4 21 /8, 45 /8 23 /8, 47 /8, 59 /8 237/16, 477/16 24, 48, 60 6, 8, 10, 12 213/4, 453/4, 573/4 213/8, 453/8 235/8, 475/8, 595/8 237/16, 477/16 53/16 24, 48, 60 6, 8, 10, 12 213/4, 453/4, 573/4 213/8, 453/8 235/8, 475/8, 595/8 237/16, 477/16 8 /16 7 /16 24, 48, 60 6, 8, 10, 12 21 /4, 45 /4, 57 /4 21 /8, 45 /8 23 /8, 47 /8, 59 /8 237/16, 477/16 101/16 93/16 24, 48, 60 6, 8, 10, 12 213/4, 453/4, 573/4 213/8, 453/8 235/8, 475/8, 595/8 237/16, 477/16 1 1 3 3 3 3 3 3 3 3 3 3 3 3 5 5 5 5 Bolt-Slot 5 5 FLOWTEE APPLICATIONS FLOWTEE DIMENSIONAL DATA C35 flowbar Redefine your comfort zone™ | www.titus-hvac.com PERFORMANCE DATA FL-10 / FL-15 / FL-20 / FL-25 / FL-30 WITH CONTINUOUS SLOT PLENUM & HIGHTHROW PATTERN CONTROLLER 1-Slot 1.0” Slot Width 2-Slot 1-Slot 1.5” Slot Width 2-Slot 1-Slot C 2.0” Slot Width 2-Slot 1-Slot 2.5” Slot Width 2-Slot 1-Slot 3.0” Slot Width PERFORMANCE DATA 2-Slot Airflow, cfm/ft. Static Pressure NC (Noise Criteria) Throw Airflow, cfm/ft. Static Pressure NC (Noise Criteria) Throw Airflow, cfm/ft. Static Pressure NC (Noise Criteria) Throw Airflow, cfm/ft. Static Pressure NC (Noise Criteria) Throw Airflow, cfm/ft. Static Pressure NC (Noise Criteria) Throw Airflow, cfm/ft. Static Pressure NC (Noise Criteria) Throw Airflow, cfm/ft. Static Pressure NC (Noise Criteria) Throw Airflow, cfm/ft. Static Pressure NC (Noise Criteria) Throw Airflow, cfm/ft. Static Pressure NC (Noise Criteria) Throw Airflow, cfm/ft. Static Pressure NC (Noise Criteria) Throw 25 0.028 <10 5-8-14 50 0.028 <10 7-11-20 30 0.032 <10 6-10-16 60 0.032 <10 9-14-22 30 0.020 <10 5-9-16 60 0.020 <10 7-12-22 30 0.012 <10 4-8-16 60 0.012 <10 6-11-22 30 0.011 <10 3-7-15 60 0.011 <10 5-10-21 • All pressures are in inches of water • Pressure loss data assumes a duct velocity less than 800 fpm in the inlet duct • Isothermal throw values given are for terminal velocities of 150, 100 and 50 fpm • Throw data based on active sections 4 feet long. For a 2-foot section, the throw values are 0.72 times those shown. For a 10-foot continuous length, the throw values are 1.7 times those shown, 1.8 for 12-foot units. • Each NC value represents the noise criteria that will not be exceeded by the sound pressure in any of the octave bands, 2 through 7, with a room absorption of 10dB, re 10-12 watts, for a 4-foot section. (See Table A for other lengths). For supply units used as a return, add 3 NC. Table A, NC Correction for length C36 40 0.072 16 9-13-18 75 0.063 17 11-17-25 45 0.073 14 10-14-19 85 0.065 16 13-19-27 50 0.057 11 9-14-20 95 0.051 12 13-19-28 55 0.041 11 10-15-21 105 0.038 13 13-20-29 60 0.044 <10 10-15-22 120 0.044 <10 14-21-32 Length, Feet Supply Return 2 -2 0 4 0 +3 6 +2 +5 8 +3 +6 55 0.136 26 12-15-21 100 0.113 26 15-20-29 60 0.130 24 13-16-22 110 0.109 24 17-21-30 70 0.111 22 13-17-24 130 0.096 22 17-23-33 80 0.088 23 14-18-26 150 0.077 24 19-25-35 90 0.100 18 15-19-27 180 0.100 21 21-27-39 70 0.221 33 14-17-24 125 0.176 33 19-23-32 75 0.203 31 14-18-25 135 0.164 31 19-24-33 90 0.184 30 16-19-27 165 0.154 30 21-26-37 105 0.151 31 17-21-29 195 0.130 32 23-28-40 120 0.177 27 18-22-32 240 0.177 30 26-32-45 85 0.325 39 15-19-27 150 0.253 39 20-25-35 90 0.292 37 16-19-27 160 0.231 36 21-26-36 110 0.274 36 17-21-30 200 0.227 36 23-29-41 130 0.232 38 19-23-33 240 0.197 38 26-32-45 150 0.277 34 20-25-35 300 0.277 37 29-35-50 100 0.450 44 17-20-29 175 0.345 44 22-27-38 105 0.398 42 17-21-29 185 0.309 41 23-28-39 130 0.383 41 19-23-33 235 0.313 41 25-31-44 155 0.329 43 21-25-36 285 0.278 44 28-34-49 180 0.399 40 22-27-39 360 0.399 43 32-39-55 115 0.596 49 18-22-31 200 0.450 48 23-29-41 120 0.520 48 18-22-32 210 0.398 45 24-29-42 150 0.510 46 20-25-35 270 0.413 46 27-33-47 180 0.444 48 22-27-39 330 0.373 48 30-37-52 210 0.543 45 24-29-42 420 0.543 48 34-42-59 • Data obtained from tests conducted in accordance with ASHRAE Standard 70-2006 “Method of Testing for Rating the Performance of Air Outlets and Inlets” • The tests were conducted with no plenum effect for pressure or sound • Throw values for HighThrow units are based on a one-way discharge from the slot • Throws listed are for one-way air pattern. For divided airflow, select the airflow in each direction according to the number of slots aimed in that direction, with the total airflow apportioned between slots. See section, Engineering Guidelines and the topic ‘Procedure to Obtain Catalog Throw Data’ in this catalog for throw information. • For continuous lengths it is recommended that maximum active lengths are no longer than 10 feet Table B, Throw Correction Multiplier for length 10 +5 +8 Length, Feet Throw Correction 2 0.72 4 0 8 1.5 10 1.7 12 1.8 flowbar PERFORMANCE DATA 1.0” Slot Width 1-Slot 6” Inlet 2 ft. 4 ft. 5 ft. 1.0” Slot Width 1-Slot 8” Inlet 2 ft. 4 ft. 5 ft. 1.5” Slot Width 1-Slot 6” Inlet 2 ft. 4 ft. 1.5” Slot Width 1-Slot 8” Inlet 2 ft. 4 ft. 5 ft. 25 0.008 0.007 <10 1-2-6 40 0.007 0.005 <10 1-2-6 50 0.009 0.005 <10 1-2-7 50 0.029 0.028 <10 3-6-10 70 0.016 0.014 <10 2-5-11 80 0.015 0.012 <10 2-5-12 40 0.017 0.014 <10 2-5-9 80 0.025 0.014 <10 3-6-13 90 0.025 0.012 <10 3-6-13 40 0.015 0.014 <10 2-5-9 80 0.018 0.014 <10 3-6-13 90 0.016 0.012 <10 3-6-13 50 0.032 0.028 <10 3-6-10 80 0.028 0.018 <10 3-6-13 100 0.034 0.018 <10 3-7-14 75 0.066 0.063 <10 6-9-12 110 0.040 0.034 <10 6-9-15 130 0.039 0.030 <10 6-9-16 70 0.052 0.044 <10 5-8-12 120 0.056 0.032 <10 6-10-16 140 0.060 0.028 <10 6-10-17 70 0.047 0.044 <10 5-8-12 130 0.047 0.038 <10 7-10-16 150 0.044 0.032 <10 7-11-18 75 0.072 0.063 <10 6-9-12 120 0.064 0.041 <10 6-10-16 150 0.077 0.041 <10 7-11-18 100 0.118 0.113 19 8-10-14 150 0.075 0.063 13 8-12-18 180 0.075 0.058 13 9-13-19 100 0.106 0.090 16 8-10-14 160 0.099 0.058 12 9-13-18 190 0.111 0.052 12 9-14-20 100 0.095 0.090 14 8-10-14 180 0.090 0.073 15 10-14-19 210 0.086 0.064 14 10-15-21 100 0.129 0.113 20 8-10-14 160 0.114 0.072 16 9-13-18 200 0.137 0.072 18 10-14-20 125 0.184 0.176 27 9-11-16 190 0.120 0.102 22 10-14-20 230 0.122 0.095 22 11-15-22 130 0.180 0.152 25 9-12-16 200 0.155 0.090 20 11-14-20 240 0.176 0.083 20 11-16-22 130 0.161 0.152 24 9-12-16 230 0.146 0.119 24 12-15-22 270 0.143 0.105 24 13-17-24 Performance notes appear at end of table 125 0.201 0.176 28 9-11-16 200 0.177 0.113 24 11-14-20 250 0.214 0.113 26 12-16-23 150 0.265 0.253 34 10-12-18 230 0.176 0.149 29 12-15-22 280 0.181 0.141 29 14-17-24 160 0.272 0.231 33 11-13-18 240 0.223 0.130 27 13-16-22 290 0.258 0.121 27 14-17-24 160 0.244 0.231 32 11-13-18 280 0.217 0.177 32 14-17-24 330 0.213 0.157 31 15-18-26 150 0.290 0.253 35 10-12-18 240 0.255 0.162 31 13-16-22 300 0.308 0.162 33 14-18-25 175 0.361 0.345 40 11-13-19 270 0.243 0.205 35 14-17-24 330 0.252 0.196 35 15-18-26 190 0.384 0.326 40 11-14-20 280 0.304 0.177 33 14-17-24 340 0.354 0.167 33 15-19-27 190 0.344 0.326 38 11-14-20 330 0.301 0.246 38 15-18-26 390 0.298 0.220 37 16-20-28 175 0.394 0.345 40 11-13-19 280 0.348 0.221 37 14-17-24 350 0.419 0.221 38 16-19-27 200 0.471 0.450 44 12-14-20 310 0.320 0.271 40 15-18-25 380 0.334 0.260 40 16-20-28 220 0.515 0.437 46 12-15-21 320 0.397 0.231 38 15-18-26 390 0.466 0.220 39 16-20-28 220 0.461 0.437 45 12-15-21 380 0.400 0.326 43 16-20-28 450 0.396 0.292 43 18-22-31 C PERFORMANCE DATA 5 ft. Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Redefine your comfort zone™ | www.titus-hvac.com FL-10 / FL-15 / FT-10 / FT-15 - 1-SLOT, HIGHTHROW WITH TITUS PLENUM C37 flowbar FL-20 / FL-25 / FT-20 - 1-SLOT, HIGHTHROW WITH TITUS PLENUM 2 ft. 2.0” Slot Width 1-Slot 8” Inlet Redefine your comfort zone™ | www.titus-hvac.com PERFORMANCE DATA 4 ft. 5 ft. C 2.0” Slot Width 1-Slot 12” Inlet 2 ft. 4 ft. 5 ft. 4 ft. 5 ft. 2 ft. 2.5” Slot Width 1-Slot 12” Inlet PERFORMANCE DATA 2.5” Slot Width 1-Slot 10” Inlet 2 ft. 4 ft. 5 ft. C38 Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, CFM Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw 50 0.015 0.014 <10 2-5-10 90 0.016 0.011 <10 3-6-13 100 0.014 0.009 <10 2-5-13 50 0.014 0.014 <10 2-5-10 90 0.012 0.011 <10 3-6-13 100 0.010 0.009 <10 2-5-13 100 0.036 0.034 <10 6-10-14 140 0.021 0.017 <10 5-9-17 150 0.017 0.012 <10 4-9-18 100 0.035 0.034 <10 6-10-14 140 0.019 0.017 <10 5-9-17 150 0.015 0.012 <10 4-9-18 85 0.045 0.041 <10 6-9-13 150 0.043 0.032 <10 7-11-18 165 0.039 0.025 <10 6-10-18 90 0.047 0.046 <10 6-9-14 165 0.041 0.039 <10 8-12-18 190 0.036 0.033 <10 8-12-20 145 0.076 0.072 <10 9-12-17 220 0.052 0.041 <10 10-15-21 240 0.044 0.032 <10 10-15-22 145 0.074 0.072 <10 9-12-17 225 0.049 0.043 <10 10-15-22 250 0.041 0.034 <10 10-15-23 120 0.089 0.082 12 8-11-16 210 0.085 0.063 20 10-15-21 230 0.075 0.048 19 10-15-22 130 0.098 0.096 <10 9-12-16 240 0.087 0.082 13 11-16-22 280 0.079 0.071 15 12-17-24 190 0.131 0.124 17 11-14-20 300 0.096 0.077 20 14-18-25 330 0.083 0.060 18 13-18-26 190 0.127 0.124 12 11-14-20 310 0.092 0.082 16 14-18-25 350 0.080 0.067 16 14-19-27 155 0.149 0.136 21 10-13-18 270 0.141 0.103 29 13-17-24 295 0.124 0.079 28 13-17-25 170 0.167 0.164 13 11-13-19 315 0.151 0.141 23 15-18-26 370 0.138 0.124 25 16-20-28 235 0.201 0.189 26 13-16-22 380 0.154 0.124 29 16-20-28 420 0.134 0.097 28 17-21-29 235 0.195 0.189 21 13-16-22 395 0.149 0.134 26 17-20-29 450 0.132 0.111 26 18-22-31 Performance notes appear at end of table 190 0.223 0.205 28 11-14-20 330 0.210 0.154 36 15-18-26 360 0.184 0.118 36 15-19-27 210 0.254 0.250 20 12-15-21 390 0.231 0.216 31 16-20-28 460 0.213 0.192 33 18-22-31 280 0.285 0.269 33 14-17-24 460 0.226 0.181 37 18-22-31 510 0.197 0.143 36 19-23-32 280 0.277 0.269 28 14-17-24 480 0.221 0.197 34 18-22-32 550 0.196 0.166 34 19-24-34 225 0.313 0.287 35 12-15-22 390 0.294 0.216 42 16-20-28 425 0.256 0.164 42 17-21-30 250 0.361 0.354 27 13-16-23 465 0.328 0.306 37 18-22-31 550 0.305 0.274 39 19-24-34 325 0.384 0.362 39 15-18-26 540 0.311 0.250 44 19-24-33 600 0.273 0.197 43 20-25-35 325 0.373 0.362 34 15-18-26 565 0.306 0.273 41 20-24-34 650 0.274 0.232 41 21-26-37 260 0.418 0.383 40 13-16-23 450 0.391 0.287 48 18-22-31 490 0.341 0.218 47 18-23-32 290 0.485 0.477 32 14-17-24 540 0.443 0.413 43 19-24-33 640 0.413 0.372 45 21-26-36 370 0.498 0.469 44 16-20-28 620 0.410 0.329 49 21-25-36 690 0.361 0.261 49 22-27-38 370 0.483 0.469 40 16-20-28 650 0.405 0.362 46 21-26-37 750 0.365 0.308 47 23-28-39 flowbar PERFORMANCE DATA 3.0” Slot Width 1-Slot 10” Inlet 2 ft. 4 ft. 5 ft. 3.0” Slot Width 1-Slot 12” Inlet 2 ft. 4 ft. 5 ft. Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw 125 0.051 0.048 <10 7-11-16 200 0.039 0.031 <10 8-13-20 220 0.034 0.024 <10 8-12-21 125 0.050 0.048 <10 7-11-16 200 0.035 0.031 <10 8-13-20 220 0.029 0.024 <10 8-12-21 170 0.095 0.089 <10 10-13-19 275 0.074 0.058 <10 12-17-24 310 0.068 0.047 <10 12-17-25 170 0.092 0.089 <10 10-13-19 290 0.073 0.065 <10 12-17-24 330 0.065 0.054 <10 12-18-26 260 0.222 0.208 23 13-16-23 425 0.177 0.139 25 17-21-30 490 0.169 0.118 25 18-23-32 260 0.215 0.208 19 13-16-23 470 0.192 0.170 26 18-22-31 550 0.180 0.149 26 19-24-34 305 0.306 0.286 30 15-18-25 500 0.245 0.192 32 19-23-32 580 0.236 0.166 33 20-24-35 305 0.296 0.286 26 15-18-25 560 0.273 0.241 33 20-24-34 660 0.259 0.215 34 21-26-37 350 0.403 0.377 36 16-19-27 575 0.324 0.254 39 20-24-34 670 0.315 0.221 40 21-26-37 350 0.389 0.377 32 16-19-27 650 0.368 0.325 40 21-26-37 770 0.352 0.292 41 23-28-40 395 0.513 0.480 41 17-20-29 650 0.414 0.325 44 21-26-37 760 0.406 0.284 46 23-28-40 395 0.496 0.480 37 17-20-29 740 0.477 0.421 45 23-28-39 880 0.460 0.381 47 25-30-43 • Plenums not provided by Titus may demonstrate performance variations from data published by Titus. If a factory-engineered plenum is not provided, Titus does not guarantee performance. • Throw values for HighThrow units are based on a one-way discharge from the slot • Throws listed are for one-way air pattern. For divided airflow, select the airflow in each direction according to the number of slots aimed in that direction, with the total airflow apportioned between slots. See section, Engineering Guidelines and the topic ‘Procedure to Obtain Catalog Throw Data’ in this catalog for throw information. • For continuous lengths it is recommended that maximum active lengths are no longer than 10 feet C PERFORMANCE DATA • All pressures are in inches of water • Isothermal throw values given are for terminal velocities of 150, 100 and 50 fpm • Each NC value represents the noise criteria that will not be exceeded by the sound pressure in any of the octave bands, 2 through 7, with a room absorption of 10dB, re 10-12 watts • Data obtained from tests conducted in accordance with ASHRAE Standard 70-2006 “Method of Testing for Rating the Performance of Air Outlets and Inlets” • Conducted tests with FlowBar and plenums as a composite assembly 215 0.152 0.142 15 12-15-21 350 0.120 0.094 17 15-19-27 400 0.112 0.079 17 15-20-29 215 0.147 0.142 11 12-15-21 380 0.126 0.111 16 16-20-28 440 0.115 0.095 17 16-21-30 Redefine your comfort zone™ | www.titus-hvac.com FL-30 - 1-SLOT, HIGHTHROW WITH TITUS PLENUM C39 flowbar FL-10 / FL-15 / FT-10 / FT-15 - 2-SLOT, HIGHTHROW WITH TITUS PLENUM 2 ft. 1.0” Slot Width 2-Slot 8” Inlet Redefine your comfort zone™ | www.titus-hvac.com PERFORMANCE DATA 4 ft. 5 ft. C 1.0” Slot Width 2-Slot 10” Inlet 2 ft. 4 ft. 5 ft. 4 ft. 5 ft. 2 ft. 1.5” Slot Width 2-Slot 12” Inlet PERFORMANCE DATA 1.5” Slot Width 2-Slot 8” Inlet 2 ft. 4 ft. 5 ft. C40 Airflow, CFM Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, CFM Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, CFM Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, CFM Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, CFM Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, CFM Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw 80 0.021 0.018 <10 3-6-13 160 0.031 0.018 <10 4-9-18 200 0.039 0.018 <10 5-10-20 80 0.019 0.018 <10 3-6-13 160 0.023 0.018 <10 4-9-18 200 0.026 0.018 <10 5-10-20 120 0.040 0.032 <10 6-10-16 240 0.062 0.032 <10 9-14-22 300 0.079 0.032 <10 10-15-25 120 0.034 0.032 <10 6-10-16 240 0.038 0.032 <10 9-14-22 300 0.042 0.032 <10 10-15-25 120 0.048 0.041 <10 6-10-16 230 0.064 0.037 <10 9-13-22 280 0.075 0.035 <10 9-14-24 130 0.051 0.048 <10 7-11-16 240 0.053 0.041 <10 9-14-22 295 0.057 0.039 <10 10-15-25 160 0.071 0.058 11 9-13-18 310 0.103 0.054 15 12-18-25 370 0.120 0.049 14 13-19-28 170 0.068 0.065 11 9-13-19 320 0.068 0.058 14 12-18-26 400 0.074 0.058 15 14-20-29 160 0.085 0.072 15 9-13-18 300 0.109 0.063 18 11-17-25 360 0.125 0.058 18 12-18-27 180 0.098 0.091 19 10-14-19 320 0.094 0.072 19 12-18-26 390 0.100 0.069 20 13-20-28 200 0.111 0.090 19 11-14-20 380 0.155 0.081 22 14-20-28 440 0.169 0.070 21 15-21-30 220 0.114 0.109 21 12-15-21 400 0.106 0.090 22 15-20-29 500 0.116 0.090 24 17-23-32 200 0.133 0.113 24 11-14-20 370 0.167 0.096 25 14-20-28 440 0.186 0.087 25 15-21-30 230 0.160 0.149 28 12-15-22 400 0.146 0.113 27 15-20-29 485 0.155 0.106 28 17-22-32 240 0.159 0.130 26 13-16-22 450 0.218 0.114 28 17-22-31 510 0.227 0.094 26 17-23-32 270 0.172 0.164 29 14-17-24 480 0.153 0.130 29 18-22-32 600 0.166 0.130 31 20-25-35 Performance notes appear at end of table 240 0.192 0.162 30 13-16-22 440 0.235 0.136 32 17-21-30 520 0.260 0.122 31 18-23-33 280 0.237 0.221 35 14-17-24 480 0.211 0.162 34 18-22-32 580 0.222 0.152 34 20-24-35 280 0.217 0.177 32 14-17-24 520 0.291 0.152 34 19-23-33 580 0.294 0.121 31 20-24-35 320 0.241 0.231 35 15-18-26 560 0.209 0.177 35 20-24-34 700 0.226 0.177 36 22-27-38 280 0.261 0.221 36 14-17-24 510 0.316 0.183 37 19-23-32 600 0.347 0.162 36 20-25-35 330 0.329 0.307 41 15-18-26 560 0.287 0.221 40 20-24-34 675 0.301 0.205 40 22-26-37 320 0.283 0.231 37 15-18-26 590 0.375 0.196 38 20-25-35 650 0.369 0.152 35 21-26-37 370 0.323 0.309 40 16-20-28 640 0.272 0.231 40 21-26-36 800 0.296 0.231 41 23-29-41 320 0.341 0.288 41 15-18-26 580 0.409 0.237 42 20-24-35 680 0.445 0.208 41 22-27-38 380 0.437 0.407 47 16-20-28 640 0.374 0.288 45 21-26-36 770 0.392 0.267 45 23-28-40 360 0.359 0.292 41 16-19-27 660 0.469 0.246 43 21-26-37 720 0.453 0.187 39 22-27-39 420 0.416 0.398 45 17-21-29 720 0.345 0.292 44 22-27-39 900 0.374 0.292 46 25-31-43 flowbar PERFORMANCE DATA 2.0” Slot Width 2-Slot 8” Inlet 2 ft. 4 ft. 5 ft. 2.0” Slot Width 2-Slot 12” Inlet 2 ft. 4 ft. 5 ft. 2.5” Slot Width 2-Slot 10” Inlet 2 ft. 4 ft. 2.5” Slot Width 2-Slot 12” Inlet 2 ft. 4 ft. 5 ft. 120 0.028 0.020 <10 5-9-16 240 0.050 0.020 12 7-12-22 260 0.050 0.015 11 6-12-23 120 0.022 0.020 <10 5-9-16 240 0.026 0.020 <10 7-12-22 280 0.026 0.018 <10 6-13-24 80 0.007 0.005 <10 2-4-11 160 0.011 0.005 <10 3-6-15 200 0.014 0.005 <10 3-6-17 80 0.006 0.005 <10 2-4-11 160 0.008 0.005 <10 3-6-15 200 0.010 0.005 <10 3-6-17 165 0.053 0.039 11 8-12-18 300 0.078 0.032 21 10-15-25 325 0.078 0.024 20 9-15-26 195 0.058 0.054 <10 9-14-20 330 0.050 0.039 12 11-17-26 380 0.047 0.033 14 11-17-28 160 0.027 0.022 <10 7-11-18 280 0.033 0.017 <10 8-13-24 335 0.039 0.015 <10 8-14-26 170 0.028 0.025 <10 8-11-19 295 0.027 0.019 <10 9-14-25 350 0.029 0.017 <10 9-15-27 210 0.085 0.063 20 10-15-21 360 0.112 0.046 27 12-18-27 390 0.112 0.034 26 12-18-28 270 0.111 0.103 17 13-17-24 420 0.080 0.063 21 14-21-29 480 0.076 0.052 22 14-22-32 240 0.061 0.049 11 11-16-22 400 0.068 0.034 15 13-19-29 470 0.077 0.030 17 13-20-31 260 0.065 0.058 <10 12-16-23 430 0.058 0.040 13 14-21-30 500 0.060 0.034 14 14-21-32 255 0.125 0.092 27 12-16-23 420 0.153 0.063 33 14-21-29 455 0.153 0.047 32 14-20-31 345 0.181 0.169 26 15-19-27 510 0.118 0.092 28 17-23-32 580 0.110 0.076 29 17-24-35 320 0.109 0.088 22 14-18-26 520 0.115 0.058 26 17-23-33 605 0.127 0.050 27 17-25-35 350 0.117 0.105 21 16-19-27 565 0.101 0.068 25 18-24-34 650 0.101 0.058 25 19-26-37 Performance notes appear at end of table 300 0.174 0.128 33 14-18-25 480 0.200 0.082 38 16-22-32 520 0.200 0.061 37 16-23-33 420 0.268 0.250 33 17-21-29 600 0.164 0.128 34 20-25-35 680 0.152 0.105 35 20-27-38 400 0.171 0.137 31 17-20-29 640 0.174 0.088 35 20-26-36 740 0.190 0.075 35 21-28-39 440 0.185 0.166 31 17-21-30 700 0.155 0.105 33 22-27-38 800 0.153 0.088 34 23-29-41 345 0.230 0.169 38 15-19-27 540 0.253 0.103 43 18-24-33 585 0.253 0.078 42 18-25-35 495 0.372 0.347 39 18-23-32 690 0.217 0.169 39 22-27-38 780 0.200 0.138 40 23-28-40 480 0.246 0.197 39 18-22-32 760 0.245 0.124 42 23-28-40 875 0.266 0.105 42 25-30-43 530 0.269 0.241 38 19-23-33 835 0.220 0.149 41 24-29-42 950 0.215 0.124 41 26-31-44 390 0.294 0.216 42 16-20-28 600 0.312 0.128 47 20-25-35 650 0.312 0.096 46 19-26-37 570 0.493 0.460 45 20-24-34 780 0.277 0.216 44 23-28-40 880 0.254 0.176 45 25-30-43 560 0.334 0.269 45 20-24-34 880 0.328 0.166 48 25-30-43 1010 0.354 0.140 48 26-32-46 620 0.368 0.329 45 21-25-36 970 0.297 0.202 47 26-32-45 1100 0.288 0.166 47 28-34-48 C PERFORMANCE DATA 5 ft. Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Redefine your comfort zone™ | www.titus-hvac.com FL-20 / FL-25 / FT-20 - 2-SLOT, HIGHTHROW WITH TITUS PLENUM C41 flowbar FL-30 - 2-SLOT, HIGHTHROW WITH TITUS PLENUM 2 ft. 3.0” Slot Width 2 Slot 10” Inlet Redefine your comfort zone™ | www.titus-hvac.com PERFORMANCE DATA 4 ft. 5 ft. C 3.0” Slot Width 2 Slot 12” Inlet 2 ft. 4 ft. 5 ft. Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw Airflow, cfm Total Pressure Static Pressure NC (Noise Criteria) Throw 80 0.006 0.005 <10 1-3-10 150 0.009 0.004 <10 2-4-13 180 0.011 0.004 <10 2-4-14 80 0.006 0.005 <10 1-3-10 150 0.007 0.004 <10 2-4-13 180 0.007 0.004 <10 2-4-14 180 0.032 0.025 <10 7-11-19 300 0.036 0.017 <10 7-13-25 350 0.041 0.015 <10 7-14-27 180 0.028 0.025 <10 7-11-19 310 0.028 0.018 <10 8-14-25 360 0.029 0.016 <10 7-14-27 PERFORMANCE DATA • All pressures are in inches of water • Isothermal throw values given are for terminal velocities of 150, 100 and 50 fpm • Each NC value represents the noise criteria that will not be exceeded by the sound pressure in any of the octave bands, 2 through 7, with a room absorption of 10dB, re 10-12 watts • The tests were conducted with the FlowBar and plenums as a composite assembly • Data obtained from tests conducted in accordance with ASHRAE Standard 70-2006 “Method of Testing for Rating the Performance of Air Outlets and Inlets” MODUFLOW 24 X 24 INCHES 1-SLOT DATA 380 0.141 0.111 20 16-20-28 600 0.145 0.069 22 18-25-35 690 0.159 0.059 23 18-27-38 380 0.126 0.111 16 16-20-28 630 0.117 0.076 19 19-26-36 720 0.116 0.064 20 19-27-39 480 0.226 0.177 31 18-22-32 750 0.226 0.108 32 22-28-39 860 0.246 0.091 33 23-30-42 480 0.201 0.177 26 18-22-32 790 0.183 0.120 30 23-29-40 900 0.182 0.100 30 24-31-43 580 0.329 0.259 39 20-24-35 900 0.326 0.156 41 25-31-43 1030 0.353 0.131 41 27-33-46 580 0.293 0.259 35 20-24-35 950 0.265 0.174 38 26-31-44 1080 0.262 0.144 38 27-33-47 680 0.453 0.356 46 22-27-38 1050 0.444 0.212 48 27-33-47 1200 0.480 0.177 48 29-35-50 680 0.403 0.356 42 22-27-38 1110 0.362 0.237 45 28-34-48 1260 0.356 0.195 45 29-36-51 • Plenums not provided by Titus may demonstrate performance variations from data published by Titus. Titus can not guarantee performance if a factory engineered plenum is not provided. • Throw values for HighThrow units are based on a one-way discharge from the slot • Throws listed are for one-way air pattern. For divided airflow, select the airflow in each direction according to the number of slots aimed in that direction, with the total airflow apportioned between slots. See section Engineering Guidelines and the topic ‘Procedure to Obtain Catalog Throw Data’ for throw information. • For continuous lengths it is recommended that maximum active lengths are no longer than 10 feet (BASED ON MF10 MODEL) 6” Dia Inlet 1” Slot Width 8” Dia Inlet 10” Dia Inlet C42 280 0.077 0.060 <10 12-17-24 450 0.081 0.039 <10 13-20-31 520 0.090 0.033 10 14-21-33 280 0.068 0.060 <10 12-17-24 470 0.065 0.043 <10 14-21-31 540 0.065 0.036 <10 14-21-33 Neck Velocity, (fpm) Velocity Pressure, (In. WG) Airflow, cfm Total Pressure, (In. WG) NC (Noise Criteria) Throw feet Airflow, cfm Total Pressure, (In. WG) NC (Noise Criteria) Throw feet Airflow, cfm Total Pressure, (In. WG) NC (Noise Criteria) Throw feet • All data based on tests conducted in accordance with ASHRAE Standard 70-2006 300 0.006 59 0.015 0-1-4 105 0.027 1-3-8 164 0.042 18 3-6-11 400 0.010 79 0.027 1-2-6 140 0.048 17 2-5-11 218 0.075 26 6-9-13 500 0.016 98 0.043 12 1-3-8 175 0.075 24 4-7-12 273 0.116 33 7-10-15 600 0.022 118 0.062 18 2-4-9 209 0.108 29 5-8-13 327 0.168 39 9-11-16 • Throw based on Isothermal air, at 150, 100 and 50 fpm terminal velocities 700 0.031 137 0.084 22 2-5-10 244 0.148 34 6-10-14 382 0.228 43 10-12-17 750 0.035 147 0.096 24 3-6-11 262 0.169 36 7-10-14 409 0.262 45 10-13-18 800 0.040 157 0.110 26 3-6-11 279 0.193 38 7-11-15 436 0.298 47 11-13-19 850 0.045 167 0.124 28 3-7-12 297 0.218 40 8-11-15 464 0.336 49 11-14-19 • NC based on a 10 dB reduction in discharge sound in all octave bands for room absorption 900 0.051 177 0.139 30 4-7-12 314 0.244 42 8-11-16 491 0.377 51 11-14-20 flowbar PERFORMANCE DATA 1.0” Slot Width 1Slot 2Slot 1.5” Slot Width 1Slot 2Slot 2.0” Slot Width 1Slot 2Slot 2.5” Slot Width 1Slot 2Slot 3.0” Slot Width 1Slot 2Slot Airflow, cfm/ft. Static Pressure NC (Noise Criteria) Throw Airflow, cfm/ft. Static Pressure NC (Noise Criteria) Throw Airflow, cfm/ft. Static Pressure NC (Noise Criteria) Throw Airflow, cfm/ft. Static Pressure NC (Noise Criteria) Throw Airflow, cfm/ft. Static Pressure NC (Noise Criteria) Throw Airflow, cfm/ft. Static Pressure NC (Noise Criteria) Throw Airflow, cfm/ft. Static Pressure NC (Noise Criteria) Throw Airflow, cfm/ft. Static Pressure NC (Noise Criteria) Throw Airflow, cfm/ft. Static Pressure NC (Noise Criteria) Throw Airflow, cfm/ft. Static Pressure NC (Noise Criteria) Throw 20 0.007 <10 2-3-7 40 0.007 <10 3-5-9 30 0.008 <10 2-4-7 60 0.008 <10 2-5-10 35 0.006 <10 1-3-7 70 0.006 <10 2-4-10 40 0.005 <10 1-3-7 80 0.005 <10 2-4-10 50 0.005 <10 1-3-8 100 0.005 <10 2-4-11 40 0.027 <10 4-7-13 85 0.031 11 7-10-20 60 0.031 <10 5-7-15 120 0.031 <10 7-10-21 75 0.026 <10 5-8-15 150 0.026 <10 7-11-21 95 0.027 <10 6-8-17 190 0.027 11 8-12-24 115 0.028 <10 6-9-18 230 0.028 <10 8-13-25 Table A, NC Correction for length 80 0.109 24 9-13-22 175 0.130 29 14-20-32 120 0.125 22 10-15-26 240 0.125 27 14-21-37 155 0.112 24 10-16-30 310 0.112 26 15-22-42 205 0.126 25 12-18-35 410 0.126 28 17-26-49 245 0.125 24 13-19-38 490 0.125 27 18-27-53 100 0.170 28 11-17-24 220 0.206 34 17-25-36 150 0.196 28 12-18-30 300 0.196 32 17-26-42 195 0.178 29 13-20-34 390 0.178 32 18-28-48 260 0.203 30 15-23-39 520 0.203 34 22-32-55 310 0.200 30 16-24-42 620 0.200 34 23-34-60 120 0.245 32 13-19-26 265 0.299 38 21-28-39 180 0.282 33 15-22-32 360 0.282 37 21-31-46 235 0.258 33 16-24-37 470 0.258 36 22-33-52 315 0.298 35 18-28-43 630 0.298 38 26-39-60 375 0.293 34 20-29-47 750 0.293 39 28-42-66 140 0.334 36 15-20-29 310 0.409 42 24-30-42 210 0.384 37 17-25-35 420 0.384 40 24-35-49 275 0.353 37 18-28-40 550 0.353 40 26-39-57 370 0.412 39 22-33-46 740 0.412 42 31-46-66 440 0.403 38 23-34-51 880 0.403 43 33-49-71 C • Data obtained from tests conducted in accordance with ASHRAE Standard 70-2006 “Method of Testing for Rating the Performance of Air Outlets and Inlets” • The tests were conducted with no plenum effect for pressure or sound • Throw values for JetThrow units are based on the pattern controller set at 0° discharge (vertical blow) • Throws listed are for one-way air pattern. For divided airflow, select the airflow in each direction according to the number of slots aimed in that direction, with the total airflow apportioned between slots. See section, Engineering Guidelines and the topic ‘Procedure to Obtain Catalog Throw Data’ in this catalog for throw information. • For continuous lengths it is recommended that maximum active lengths are no longer than 10 feet Table B, Throw Correction Multiplier for length Length, Feet 2 4 6 8 10 Length, Feet Supply -2 0 +2 +3 +5 Throw Correction Return 0 +3 +5 +6 +8 2 4 8 10 12 0.72 1 1.5 1.7 1.8 PERFORMANCE DATA • All pressures are in inches of water • Pressure loss data assumes a duct velocity less than 800 fpm in the inlet duct • Isothermal throw values given are for terminal velocities of 150, 100 and 50 fpm • Throw data based on active sections 4 feet long. For a 2-foot section, throw values are 0.72 times those shown. • For a 10-foot continuous length, the throw values are 1.7 times those shown, 1.8 for 12-foot units • Each NC value represents the noise criteria that will not be exceeded by the sound pressure in any of the octave bands, 2 through 7, with a room absorption of 10dB, re 10-12 watts for a 4-foot section (See Table A for other lengths). For supply units used as a return, add 3 NC. 60 0.061 17 7-10-19 130 0.072 22 10-15-27 90 0.070 17 7-11-22 180 0.070 19 10-15-31 115 0.062 17 8-12-23 230 0.062 19 11-16-33 150 0.068 18 9-13-26 300 0.068 22 12-19-37 180 0.067 17 9-14-28 360 0.067 21 13-20-40 Redefine your comfort zone™ | www.titus-hvac.com FL-10 / FL-15 / FL-20 / FL-25 / FL-30 WITH CONTINUOUS SLOT PLENUM AND JETTHROW PATTERN CONTROLLER C43 flowbar FL-10 / FL-15 / FT-10 / FT-15 - 1-SLOT, JETTHROW WITH TITUS PLENUM 2 ft. 1.0” Slot Width 1-Slot 8” Inlet Redefine your comfort zone™ | www.titus-hvac.com PERFORMANCE DATA 4 ft. 5 ft. C 1.0” Slot Width 1-Slot 10” Inlet 2 ft. 4 ft. 5 ft. 1.0” Slot Width 1-Slot 12” Inlet 2 ft. 4 ft. 2 ft. 1.5” Slot Width 1-Slot 8” Inlet PERFORMANCE DATA 5 ft. 4 ft. 5 ft. C44 Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw 50 0.012 0.011 <10 2-3-6 100 0.016 0.011 <10 3-4-8 110 0.014 0.008 <10 3-4-8 50 0.011 0.011 <10 2-3-6 100 0.013 0.011 <10 3-4-8 110 0.011 0.008 <10 3-4-8 50 0.011 0.011 <10 2-3-6 100 0.012 0.011 <10 3-4-8 110 0.009 0.008 <10 3-4-8 60 0.014 0.008 <10 1-3-5 120 0.031 0.008 <10 2-4-7 140 0.039 0.007 <10 2-4-8 95 0.043 0.038 <10 4-6-11 175 0.048 0.033 <10 5-7-14 195 0.045 0.026 <10 5-7-14 95 0.040 0.038 <10 4-6-11 180 0.041 0.034 <10 5-7-15 210 0.039 0.030 <10 5-8-16 95 0.039 0.038 <10 4-6-11 190 0.042 0.038 10 5-8-16 220 0.038 0.033 <10 5-8-16 110 0.046 0.026 <10 3-5-9 180 0.070 0.018 <10 4-5-11 200 0.079 0.014 <10 4-5-11 140 0.093 0.083 16 5-8-14 250 0.099 0.066 18 7-10-19 280 0.094 0.053 17 7-10-20 140 0.088 0.083 16 5-8-14 260 0.086 0.072 18 7-11-19 310 0.086 0.065 19 8-11-21 140 0.085 0.083 15 5-8-14 280 0.091 0.083 19 8-12-20 330 0.085 0.074 20 8-12-22 160 0.097 0.056 <10 5-7-14 240 0.125 0.031 <10 5-7-15 260 0.133 0.024 <10 5-7-14 185 0.163 0.146 23 7-11-16 325 0.166 0.112 25 9-13-22 365 0.159 0.091 24 9-13-23 185 0.153 0.146 22 7-11-16 340 0.147 0.123 25 9-14-22 410 0.150 0.114 26 10-15-24 185 0.149 0.146 22 7-11-16 370 0.159 0.146 26 10-15-23 440 0.151 0.132 27 11-16-25 210 0.167 0.096 16 6-9-17 300 0.195 0.049 <10 6-9-18 320 0.201 0.036 <10 6-9-17 Performance notes appear at end of table 230 0.252 0.225 29 9-13-18 400 0.252 0.170 30 11-17-24 450 0.242 0.138 29 11-17-26 230 0.236 0.225 28 9-13-18 420 0.225 0.188 30 12-17-25 510 0.232 0.177 31 13-19-27 230 0.230 0.225 27 9-13-18 460 0.247 0.225 32 13-18-26 550 0.237 0.206 32 14-20-28 260 0.257 0.147 24 7-11-19 360 0.280 0.070 16 7-11-22 380 0.284 0.050 12 7-10-21 275 0.361 0.322 34 11-14-20 475 0.356 0.240 34 13-19-26 535 0.342 0.195 33 13-20-28 275 0.338 0.322 33 11-14-20 500 0.318 0.266 35 14-19-27 610 0.331 0.253 35 15-21-30 275 0.329 0.322 32 11-14-20 550 0.352 0.322 37 15-20-28 660 0.341 0.297 37 16-22-31 310 0.365 0.209 31 9-13-21 420 0.382 0.096 22 8-13-25 440 0.381 0.067 17 8-12-24 320 0.488 0.436 39 12-15-22 550 0.477 0.322 38 15-20-28 620 0.459 0.262 37 15-21-30 320 0.457 0.436 38 12-15-22 580 0.428 0.358 39 16-21-29 710 0.449 0.343 40 18-23-32 320 0.446 0.436 38 12-15-22 640 0.477 0.436 42 18-22-30 770 0.464 0.404 42 19-24-33 360 0.492 0.282 37 10-15-23 480 0.498 0.125 27 10-15-26 500 0.492 0.087 22 9-14-27 flowbar PERFORMANCE DATA 1.5” Slot Width 1-Slot 10” Inlet 2 ft. 4 ft. 5 ft. 1.5” Slot Width 1-Slot 12” Inlet 2 ft. 4 ft. 5 ft. 2.0” Slot Width 1-Slot 8” Inlet 2 ft. 4 ft. 5 ft. 1-Slot 10” Inlet 2.0” Slot Width 4 ft. 5 ft. 60 0.009 0.008 <10 1-3-5 120 0.011 0.008 <10 2-4-7 140 0.011 0.007 <10 2-4-8 60 0.008 0.008 <10 1-3-5 120 0.009 0.008 <10 2-4-7 140 0.009 0.007 <10 2-4-8 70 0.008 0.006 <10 1-2-5 140 0.016 0.006 <10 1-3-7 150 0.016 0.004 <10 1-3-7 70 0.007 0.006 <10 1-2-5 140 0.010 0.006 <10 1-3-7 150 0.009 0.004 <10 1-3-7 125 0.037 0.034 <10 4-5-11 230 0.040 0.029 <10 5-7-14 265 0.039 0.024 <10 5-7-14 125 0.036 0.034 <10 4-5-11 240 0.037 0.031 <10 5-7-15 280 0.035 0.027 <10 5-8-15 140 0.033 0.023 <10 3-5-10 240 0.046 0.017 12 4-6-12 260 0.047 0.013 13 3-6-12 150 0.031 0.026 <10 4-5-11 265 0.035 0.021 10 4-7-13 300 0.036 0.017 11 4-7-13 190 0.086 0.079 <10 5-8-16 340 0.087 0.063 10 7-10-21 390 0.085 0.053 <10 7-11-21 190 0.082 0.079 <10 5-8-16 360 0.084 0.070 10 7-11-22 420 0.079 0.061 10 8-11-23 210 0.074 0.052 14 5-7-15 340 0.093 0.034 21 6-9-17 370 0.096 0.026 21 6-8-17 230 0.073 0.062 11 5-8-16 390 0.076 0.044 19 7-10-20 450 0.080 0.038 21 7-10-20 255 0.155 0.141 19 7-11-19 450 0.153 0.110 20 9-14-26 515 0.148 0.092 19 9-14-27 255 0.148 0.141 18 7-11-19 480 0.149 0.125 21 10-15-26 560 0.141 0.109 21 10-15-29 280 0.132 0.092 21 7-10-20 440 0.156 0.057 27 7-11-22 480 0.161 0.043 27 7-11-22 310 0.132 0.112 18 7-11-21 515 0.133 0.077 25 9-13-26 600 0.143 0.067 27 9-13-27 Performance notes appear at end of table 320 0.244 0.223 28 9-14-22 560 0.236 0.171 29 11-17-29 640 0.229 0.143 27 12-17-30 320 0.233 0.223 27 9-14-22 600 0.232 0.196 30 12-18-30 700 0.220 0.171 29 13-19-32 350 0.206 0.143 27 8-12-23 540 0.235 0.085 32 9-14-27 590 0.243 0.065 32 9-13-27 390 0.210 0.178 26 9-14-24 640 0.206 0.120 30 11-16-30 750 0.223 0.105 33 11-17-33 385 0.354 0.322 36 11-17-24 670 0.338 0.244 36 14-20-31 765 0.327 0.204 34 14-21-33 385 0.337 0.322 35 11-17-24 720 0.334 0.282 37 15-22-32 840 0.317 0.246 36 15-23-35 420 0.296 0.206 33 10-15-25 640 0.329 0.120 36 11-16-30 700 0.343 0.092 36 10-16-31 470 0.304 0.258 31 11-17-26 765 0.294 0.171 36 13-19-33 900 0.321 0.151 37 13-20-36 450 0.483 0.441 44 13-18-26 780 0.459 0.331 42 16-24-34 890 0.442 0.276 40 16-24-36 450 0.461 0.441 43 13-18-26 840 0.455 0.384 45 17-25-35 980 0.432 0.334 43 18-27-38 490 0.403 0.280 38 12-17-27 740 0.440 0.160 40 12-19-33 810 0.459 0.123 40 12-18-34 550 0.417 0.353 36 13-20-28 890 0.398 0.231 41 15-22-36 1050 0.437 0.206 42 16-24-39 C PERFORMANCE DATA 2 ft. Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Redefine your comfort zone™ | www.titus-hvac.com FL-15 / FL-20 / FT-15 / FT-20 - 1-SLOT, JETTHROW WITH TITUS PLENUM C45 flowbar C FL-20 / FL-25 / FT-20 - 1-SLOT, JETTHROW WITH TITUS PLENUM 2.0” Slot Width 1-Slot 12” Inlet 2 ft. 4 ft. 5 ft. 2 ft. 2.5” Slot Width 1-Slot 12” Inlet Redefine your comfort zone™ | www.titus-hvac.com PERFORMANCE DATA 4 ft. 5 ft. PERFORMANCE DATA 3.0” Slot Width C46 1-Slot 12” Inlet 2 ft. 4 ft. 5 ft. Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw 70 0.006 0.006 <10 1-2-5 140 0.008 0.006 <10 1-3-7 150 0.006 0.004 <10 1-3-7 80 0.005 0.005 <10 1-2-5 150 0.007 0.004 <10 1-2-7 160 0.006 0.003 <10 1-2-6 100 0.006 0.005 <10 1-2-6 200 0.009 0.005 <10 1-3-8 240 0.011 0.005 <10 1-3-8 160 0.032 0.030 <10 4-6-11 290 0.033 0.025 <10 5-7-15 330 0.031 0.020 <10 5-7-15 190 0.031 0.027 <10 4-6-12 335 0.032 0.021 <10 5-7-15 370 0.030 0.016 <10 5-7-15 225 0.031 0.026 <10 4-6-12 400 0.037 0.021 <10 5-8-16 460 0.039 0.018 <10 5-8-16 • All pressures are in inches of water. • Isothermal throw values given are for terminal velocities of 150, 100 and 50 fpm • Each NC value represents the noise criteria that will not be exceeded by the sound pressure in any of the octave bands, 2 through 7, with a room absorption of 10dB, re 10-12 watts. • Data obtained from tests conducted in accordance with ASHRAE Standard 70-2006 “Method of Testing for Rating the Performance of Air Outlets and Inlets.” • The tests were conducted with the FlowBar and plenums as a composite assembly. • Plenums not provided by Titus may demonstrate performance variations from data published by Titus. Titus can not guarantee performance if a factory engineered plenum is not provided. 250 0.079 0.073 <10 6-9-18 440 0.076 0.057 17 7-11-22 510 0.075 0.049 19 8-11-23 300 0.077 0.068 <10 6-9-19 520 0.078 0.051 <10 8-11-23 580 0.075 0.040 <10 8-11-23 350 0.076 0.064 <10 6-10-19 600 0.083 0.047 <10 8-12-24 680 0.085 0.039 <10 8-12-24 340 0.147 0.135 17 8-12-22 590 0.137 0.102 24 10-15-29 690 0.137 0.089 26 10-16-31 410 0.143 0.126 12 9-13-24 705 0.144 0.093 18 10-16-31 790 0.138 0.075 18 10-16-31 475 0.140 0.117 <10 9-13-26 800 0.148 0.083 <10 10-16-31 900 0.149 0.067 <10 11-16-32 430 0.235 0.216 25 10-15-25 740 0.215 0.160 31 12-19-33 870 0.218 0.141 32 13-20-36 520 0.231 0.203 20 11-16-27 890 0.229 0.149 26 13-20-36 1000 0.222 0.120 26 13-20-38 600 0.224 0.187 15 11-17-30 1000 0.231 0.130 17 13-20-38 1120 0.231 0.105 15 13-20-39 520 0.343 0.316 31 12-18-27 890 0.311 0.231 37 15-22-36 1050 0.318 0.206 38 16-24-39 630 0.339 0.298 26 13-20-30 1075 0.334 0.217 32 16-24-40 1210 0.324 0.176 32 16-24-42 725 0.327 0.274 24 13-20-32 1200 0.333 0.187 25 16-24-42 1340 0.331 0.150 24 16-23-44 610 0.472 0.435 36 14-21-30 1040 0.425 0.316 41 17-26-39 1230 0.436 0.283 43 18-28-42 740 0.467 0.412 33 15-23-33 1260 0.459 0.298 38 18-28-43 1420 0.447 0.243 38 19-28-45 850 0.449 0.376 31 16-24-35 1400 0.454 0.255 32 18-27-45 1560 0.449 0.203 30 18-27-48 • Throw values for JetThrow units are based on the pattern controller set at 0° discharge (vertical blow). • Throws listed are for one-way air pattern. For divided airflow, select the airflow in each direction according to the number of slots aimed in that direction, with the total airflow apportioned between slots. See section, Engineering Guidelines and the topic ‘Procedure to Obtain Catalog Throw Data’ in this catalog for throw information. • For continuous lengths it is recommended that maximum active lengths are no longer than 10 feet. flowbar PERFORMANCE DATA 1.0” Slot Width 2-Slot 8” Inlet 2 ft. 4 ft. 5 ft. 1.0” Slot Width 1-Slot 12” Inlet 2 ft. 4 ft. 5 ft. 1.0” Slot Width 2-Slot 12” Inlet 2 ft. 4 ft. 5 ft. 2-Slot 8” Inlet 1.5” Slot Width 4 ft. 5 ft. 80 0.010 0.007 <10 2-3-7 160 0.020 0.007 <10 3-5-9 200 0.027 0.007 <10 3-5-10 80 0.008 0.007 <10 2-3-7 160 0.012 0.007 <10 3-5-9 200 0.015 0.007 <10 3-5-10 80 0.007 0.007 <10 2-3-7 160 0.009 0.007 <10 3-5-9 200 0.011 0.007 <10 3-5-10 120 0.015 0.008 <10 2-4-7 240 0.037 0.008 <10 2-5-10 260 0.041 0.006 <10 2-5-10 155 0.038 0.026 <10 4-6-13 260 0.053 0.018 <10 5-8-15 300 0.061 0.015 <10 5-8-16 165 0.035 0.029 <10 5-7-14 300 0.043 0.024 <10 6-9-18 350 0.047 0.021 <10 6-9-18 170 0.034 0.031 <10 5-7-14 320 0.038 0.027 10 6-9-19 375 0.038 0.024 10 7-10-20 210 0.047 0.024 <10 4-6-13 340 0.075 0.016 <10 5-7-15 365 0.080 0.012 <10 4-7-14 230 0.083 0.056 16 6-10-18 360 0.101 0.034 15 7-11-21 400 0.109 0.027 13 7-10-21 250 0.080 0.066 17 7-10-19 440 0.092 0.051 19 9-13-25 500 0.095 0.043 18 9-13-26 260 0.079 0.072 18 7-11-19 480 0.085 0.061 20 9-14-26 550 0.082 0.051 20 10-14-28 300 0.095 0.049 <10 6-9-18 440 0.126 0.026 <10 6-9-19 470 0.132 0.019 <10 6-9-18 Performance notes appear at end of table 305 0.147 0.099 23 8-13-21 460 0.165 0.056 21 9-13-26 500 0.171 0.043 19 9-13-26 335 0.143 0.119 25 9-14-22 580 0.160 0.089 26 11-17-29 650 0.161 0.072 24 11-17-31 350 0.143 0.130 25 10-14-23 640 0.150 0.109 27 12-19-30 725 0.143 0.089 26 13-19-32 390 0.161 0.083 17 8-12-24 540 0.189 0.040 <10 8-12-23 575 0.198 0.029 <10 7-11-22 380 0.228 0.154 29 10-16-23 560 0.244 0.083 26 11-16-29 600 0.246 0.061 23 10-16-30 420 0.225 0.188 30 12-17-25 720 0.247 0.138 31 14-21-32 800 0.243 0.109 30 14-21-34 440 0.226 0.206 31 12-18-25 800 0.235 0.170 33 16-23-34 900 0.220 0.138 32 16-24-36 480 0.243 0.125 25 10-15-26 640 0.266 0.056 15 9-14-27 680 0.277 0.040 11 9-13-26 455 0.326 0.220 33 13-18-26 660 0.339 0.116 30 13-19-31 700 0.334 0.083 27 12-18-32 505 0.325 0.271 35 14-19-27 860 0.352 0.197 35 17-25-35 950 0.343 0.154 34 17-25-37 530 0.327 0.299 36 15-20-28 960 0.338 0.245 37 19-26-37 1075 0.314 0.197 36 19-28-40 570 0.343 0.177 31 12-17-29 740 0.355 0.074 21 11-16-32 785 0.369 0.054 17 10-15-30 530 0.443 0.299 37 15-20-28 760 0.450 0.154 33 15-22-33 800 0.437 0.109 30 14-21-34 590 0.443 0.370 40 16-21-29 1000 0.476 0.266 39 19-27-38 1100 0.460 0.206 37 19-28-40 620 0.448 0.409 41 17-21-30 1120 0.461 0.334 42 22-29-40 1250 0.424 0.266 40 22-30-43 660 0.460 0.237 37 13-20-31 840 0.458 0.096 26 12-18-35 890 0.475 0.069 21 11-17-34 C PERFORMANCE DATA 2 ft. Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Redefine your comfort zone™ | www.titus-hvac.com FL-10 / FL-15 / FT-10 / FT-15 - 2-SLOT, JETTHROW WITH TITUS PLENUM C47 flowbar C FL-15 / FL-20 / FT-15 / FT-20 - 2-SLOT, JETTHROW WITH TITUS PLENUM 1.5” Slot Width 2-Slot 10” Inlet 2 ft. 4 ft. 5 ft. 2 ft. 1.5” Slot Width 2-Slot 12” Inlet Redefine your comfort zone™ | www.titus-hvac.com PERFORMANCE DATA 4 ft. 5 ft. 4 ft. 5 ft. 2 ft. 2.0” Slot Width 2-Slot 10” Inlet PERFORMANCE DATA 2.0” Slot Width 2-Slot 8” Inlet 2 ft. 4 ft. 5 ft. C48 Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw 120 0.011 0.008 <10 2-4-7 240 0.020 0.008 <10 2-5-10 260 0.020 0.006 <10 2-5-10 120 0.009 0.008 <10 2-4-7 240 0.014 0.008 <10 2-5-10 260 0.013 0.006 <10 2-5-10 70 0.008 0.006 <10 1-3-7 250 0.037 0.005 <10 2-3-9 280 0.044 0.004 10 1-3-9 140 0.010 0.006 <10 1-3-7 250 0.018 0.005 <10 2-3-9 280 0.020 0.004 <10 1-3-9 230 0.040 0.029 <10 5-7-14 390 0.053 0.021 <10 6-8-17 425 0.054 0.016 <10 5-8-16 240 0.037 0.031 <10 5-7-15 415 0.041 0.023 <10 6-9-18 440 0.036 0.017 <10 6-8-17 140 0.033 0.017 12 4-6-12 355 0.074 0.009 17 3-6-13 390 0.085 0.007 18 3-6-12 275 0.038 0.022 10 5-7-14 425 0.051 0.013 16 4-8-15 460 0.054 0.010 16 4-7-15 340 0.087 0.063 10 7-10-21 540 0.101 0.040 <10 8-12-23 590 0.103 0.030 <10 8-11-23 360 0.084 0.070 10 7-11-22 590 0.083 0.047 <10 8-13-25 620 0.072 0.033 <10 8-12-24 210 0.074 0.034 21 6-9-17 460 0.124 0.015 23 5-8-16 500 0.140 0.012 24 4-8-16 410 0.084 0.049 20 7-10-21 600 0.102 0.026 24 7-11-21 640 0.105 0.019 24 7-10-20 450 0.153 0.110 20 9-14-26 690 0.165 0.065 16 10-15-30 755 0.169 0.050 13 10-14-29 480 0.149 0.125 21 10-15-26 765 0.139 0.080 19 11-16-33 800 0.120 0.056 14 10-15-31 280 0.132 0.057 27 7-11-22 565 0.187 0.023 28 7-10-20 610 0.208 0.017 28 6-10-19 545 0.149 0.087 27 9-14-27 775 0.170 0.044 30 9-14-28 820 0.173 0.031 30 9-13-26 Performance notes appear at end of table 560 0.236 0.171 29 11-17-29 840 0.244 0.096 24 12-18-35 920 0.251 0.074 21 12-18-35 600 0.232 0.196 30 12-18-30 940 0.210 0.120 27 13-20-37 980 0.181 0.084 22 13-19-38 350 0.206 0.085 32 9-14-27 670 0.263 0.033 32 8-12-24 720 0.290 0.024 32 8-11-23 680 0.232 0.135 32 11-17-31 950 0.255 0.066 35 11-17-34 1000 0.257 0.047 35 11-16-32 670 0.338 0.244 36 14-20-31 990 0.339 0.133 30 14-21-38 1085 0.350 0.102 27 14-21-40 720 0.334 0.282 37 15-22-32 1115 0.295 0.169 33 16-24-40 1160 0.253 0.117 28 15-22-41 420 0.296 0.120 36 11-16-30 775 0.352 0.044 35 9-14-28 830 0.385 0.032 36 9-13-26 815 0.333 0.194 38 14-20-34 1125 0.358 0.092 39 13-20-40 1180 0.357 0.065 39 12-19-37 780 0.459 0.331 42 16-24-34 1140 0.449 0.177 35 16-24-41 1250 0.464 0.136 32 16-24-43 840 0.455 0.384 45 17-25-35 1290 0.395 0.226 39 18-28-43 1340 0.338 0.156 34 17-26-44 490 0.403 0.160 40 12-19-33 880 0.453 0.057 38 10-16-31 940 0.494 0.041 38 10-15-30 950 0.453 0.263 43 16-24-37 1300 0.478 0.123 42 15-23-43 1360 0.475 0.086 42 14-22-43 flowbar PERFORMANCE DATA 2.0” Slot Width 2-Slot 12” Inlet 2 ft. 4 ft. 5 ft. 2.5” Slot Width 2-Slot 12” Inlet 2 ft. 4 ft. 5 ft. 3.0” Slot Width 2-Slot 12” Inlet 2 ft. 4 ft. 140 0.010 0.006 <10 1-3-7 250 0.080 0.005 <10 2-3-9 280 0.012 0.004 <10 1-3-9 150 0.010 0.004 <10 1-2-7 300 0.010 0.004 <10 1-3-9 350 0.020 0.004 <10 1-3-10 175 0.010 0.004 <10 1-3-7 320 0.080 0.003 <10 1-4-9 380 0.020 0.003 <10 1-4-9 280 0.031 0.023 <10 5-7-14 450 0.035 0.015 13 5-8-16 480 0.034 0.011 13 4-8-15 335 0.032 0.021 <10 5-7-15 540 0.043 0.014 <10 5-8-17 600 0.047 0.011 <10 4-8-17 385 0.034 0.019 <10 5-8-15 580 0.050 0.011 <10 4-9-16 645 0.051 0.009 <10 3-8-16 • All pressures are in inches of water. • Isothermal throw values given are for terminal velocities of 150, 100 and 50 fpm. • Each NC value represents the noise criteria that will not be exceeded by the sound pressure in any of the octave bands, 2 through 7, with a room absorption of 10dB, re 10-12 watts. • Data obtained from tests conducted in accordance with ASHRAE Standard 70-2006 “Method of Testing for Rating the Performance of Air Outlets and Inlets.” • The tests were conducted with the FlowBar and plenums as a composite assembly. • Plenums not provided by Titus may demonstrate performance variations from data published by Titus. Titus can not guarantee performance if a factory engineered plenum is not provided. 420 0.069 0.052 16 7-11-21 650 0.074 0.031 22 8-12-23 680 0.070 0.022 21 7-11-22 520 0.078 0.051 <10 8-11-23 780 0.090 0.029 <10 8-12-24 850 0.095 0.022 <10 8-12-24 595 0.082 0.046 <10 8-12-23 840 0.100 0.023 <10 8-13-23 910 0.101 0.017 <10 7-11-23 560 0.130 0.092 24 9-14-28 850 0.130 0.053 28 10-15-30 880 0.115 0.036 27 9-14-28 705 0.150 0.093 18 10-16-31 1020 0.160 0.049 18 11-16-32 1100 0.170 0.036 16 10-15-31 805 0.160 0.084 <12 11-17-32 1100 0.170 0.039 <10 10-17-30 1175 0.180 0.029 <10 10-16-29 700 0.193 0.143 29 12-18-32 1050 0.192 0.080 33 12-19-37 1080 0.173 0.054 32 11-17-34 890 0.229 0.149 26 13-20-36 1260 0.235 0.075 25 13-20-39 1350 0.239 0.055 24 13-19-38 1015 0.238 0.134 18 13-20-38 1360 0.270 0.060 16 13-21-38 1440 0.253 0.043 <10 12-18-36 840 0.277 0.206 35 14-21-35 1250 0.272 0.114 37 15-22-43 1280 0.242 0.077 36 14-20-41 1075 0.334 0.217 32 16-24-40 1500 0.334 0.106 31 16-23-47 1600 0.336 0.077 30 15-22-45 1225 0.347 0.195 26 16-24-42 1620 0.330 0.085 24 15-25-45 1705 0.355 0.061 13 14-21-42 980 0.378 0.280 40 16-25-38 1450 0.390 0.153 42 17-26-46 1480 0.324 0.102 40 16-24-46 1260 0.480 0.298 39 18-27-43 1740 0.449 0.142 36 18-27-50 1850 0.480 0.103 35 17-26-51 1435 0.477 0.268 33 19-28-46 1880 0.510 0.115 31 17-29-52 1970 0.510 0.081 26 16-27-49 • Throw values for JetThrow units are based on the pattern controller set at 0° discharge (vertical blow). • Throws listed are for one-way air pattern. For divided airflow, select the airflow in each direction according to the number of slots aimed in that direction, with the total airflow apportioned between slots. See section, Engineering Guidelines and the topic ‘Procedure to Obtain Catalog Throw Data’ in this catalog for throw information. • For continuous lengths it is recommended that maximum active lengths are no longer than 10 feet. C PERFORMANCE DATA 5 ft. Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Airflow, cfm Total Pressure Static Pressure NC Throw Redefine your comfort zone™ | www.titus-hvac.com FL-20 / FL-25 / FL-30 - 2-SLOT, JETTHROW WITH TITUS PLENUM C49 Notes flowbar
Similar documents
mini-Spot - Skil-Aire
2) The above unit electrical data is reflective of the standard performance data and standard options as shown on pages 4 & 5. 3) Due to a policy of continuous improvement, Skil-aire reserves the ri...
More information