POLYETHYLENE PUMP WELLS
MPPS���
SPECIFICATIONS
Depth:
700mm
Inner Diameter: 410 mm
Nominal Litres: 100
Access Cover:
450 x 450mm
Approximate Weight: 15kg
MPPS���
SPECIFICATIONS
Depth:
900mm
Outer Diameter: 730mm
Inner Diameter: 650mm
Nominal Litres: 250
Access Cover:
600 x 600mm
Approximate Weight: 25kg
MPPS���
SPECIFICATIONS
Depth:
1200mm
Outer Diameter: 1120mm
Inner Diameter: 1000mm
Nominal Litres: 900
Access Cover:
600 x 600mm
Approximate Weight: 45kg
���L - ���L
POLYETHYLENE PUMP WELLS ����L - ����L
CONSTRUCTION
• Polyethylene tank
• All in-tank fittings incorporated in the packaged pump station as follows:
PVC ball valve, non-return valve and barrel unions; PVC interconnecting
pipework
• Inlet Pipe to be installed by plumber unless otherwise specified
APPLICATIONS
Raw Sewage
Trade Waste
Effluent
Stormwater
PUMP OPTIONS
Single Pump with or without
Dual Pumps guide rails
}
MPPS����
SPECIFICATIONS
Depth:
1600mm
Outer Diameter: 1120mm
Inner Diameter: 1000mm
Nominal Litres: 1200
Access Cover:
600 x 600mm
Approximate Weight: 62kg
MPPS����
SPECIFICATIONS
Depth:
2125mm
Outer Diameter: 1730mm
Inner Diameter: 1600mm
Nominal Litres: 3000
Access Cover:
900 x 600mm
Approximate Weight: 165kg
TYPICAL SINGLE PUMP STATION
Poly Pedestrain Lid
Liquid Level Alarm
(OPTIONAL)
Outlet
PVC Ball Valve
PVC Check Valve / Union
Automatic Submersible Pump
High Level Alarm (OPTIONAL)
Pump Float Switch
TYPICAL DUAL PUMP STATION
Dual Pump Controller
access cover
Optional guiderailswith
auto-couplings for quick
removal and reinstallation
of pumps
Selection of PVC,
bronze or stainless steel
valves available.
Rotomoulded
polyethylene tank
with heavy duty ribbing
adds strength assists in
antifloatation.
PVC or polyethylene
pipework for a long,
maintenance free life.
Float switch and
level probe options
available for reliable
pump control
Dual heavy-duty
submersible sewage
or stormwater pumps.
wide rang of options available.
Moulded inlet stubs
ensure leak-free
installation
no damage to the
environment.
ACCESS COVERS
ACCESS COVER OPTIONS FOR KPPS���L PUMP STATION
MODEL NO.
DESCRIPTION
HAC44LD
HAC44HD
HAC44LDG
450x450 Light Duty Cast Iron Solid Top
450x450 Heavy Duty Cast Iron Solid Top
450x450 Light Duty Galvanised Grate
CLASS
B
D
B
ACCESS COVER OPTIONS FOR KPPS���, ��� & ����L PUMP STATION
MODEL NO.
DESCRIPTION
HAC66LD
HAC66HD
HAC66LDG
600x600 Light Duty Cast Iron Solid Top
600x600 Heavy Duty Cast Iron Solid Top
600x600 Light Duty Galvanised Grate
CLASS
B
D
B
ACCESS COVER OPTIONS FOR KPPS����L PUMP STATION
MODEL NO.
DESCRIPTION
HAC69LD
HAC69HD
HAC69LDG
600x900 Light Duty Cast Iron Solid Top
600x900 Heavy Duty Cast Iron Solid Top
600x900 Light Duty Galvanised Grate
Other options available on request including:
• Concrete infill covers
• Multipart covers
• Paver infill covers
• Tile infill covers
• Stainless steel or brass edged covers
• Round Covers
• Gas tight covers
• Bolt down covers
CLASS
B
D
B
DUAL & SINGLE PUMP CONTROLLERS
OUTER DOOR
CONTROLLER
OPTION
LOCKABLE
INNER DOOR
CONTROLLER
OPTION
Applications
• Submersible Sewage
• Submersible Storm Water
• Constant Pressure Systems
• Hot Water Circulation Systems
• Transfer Pumping Systems
Hardware Features
• IP 65 Weather Proof, Powder Coated Metal Enclosure c/w removable gland plate
• Lockable Main Isolator
• Individual Pump Isolation
• Circuit Breaker protected Control Circuit
• Low Voltage Control and input Circuitry
• Advanced Micro Processor Control Module
• Distinctive, Highly durable and aesthetically attractive Electronic Keypad
• Auto/Off/Manual Operation of Pumps
• Thermal Overload Protection of Pump Motors
• LED Indicator Lights for System Status indication
• Visual and Audible Alarms c/w Mute Switch
• User friendly, clearly labelled, Din Rail mounted, Input and Output Terminal Connection
Features
• Auto Alternation of Pump Duty (Dual Pump Applications)
• Provision for 4 digital + 1 Analogue inputs (typically Low Level, Stop/Start, Standby In and High Level)
• Lamp, Strobe and Buzzer Test feature
• Level Alarm Delay feature avoiding nuisance tripping
• Maximum Run Time and Auto Alternation Feature
• Anti Seize/Freeze feature, for Low Use and Seasonal Pumping applications
• Maximum Idle Time Feature, for “pump out ” of residual in Pump Well situations
• Smart “Auto Silencing” and “Chirp Mode” audible Alarm
• Delayed Start and Minimum Run Time Feature
• Delayed Stand by Pump Start, avoids two motors starting simultaneously
• Optional “Time Out” on Manual Pump Mode automatic reset to Auto
• No Flow/Pressure – Inbuilt Timer feature
• Interconnectable with Remote Status Indicator panel, via simple data connection
• Interconnectable with Building Monitoring System Module, via simple data connection
LIQUID LEVEL ALARMS
1265 Series Alarms
The Maxijet Liquid Level Alarms are designed to provide warning
indication when storage (Effluent, Grey Water or Rain Water etc) tank is
either empty or full.
Warning indication is determined by a float switch.
Warnings are;
Audio (buzzer)
Visual (LED Pilot Light and/or Strobe)
The Buzzer can be muted via a mute button. If not muted the Audible
buzzer will automatically silence after 5 minutes. If a continuously
sounding audible alarm is required, this can be done by changing the
Jumper position on the circuit board.
The visual alarms will continue to remain on, until the alarm condition is eradicated.
A standard feature of the Level Alarm is a ‘Voltage Free’ (5Amp rated) output for connection
to auxiliary devices.
Controller can be installed up to 50m from the tank being monitored. Float Switch cabling is ‘safe’,
low voltage circuitry.
FLOAT SWITCHES
9000 Series Float Switches
The 9000 Series Maxijet Float Switch, which utilises an innovative,
yet simple ‘fool proof’ switching concept, has greatly enhanced
Float Switch reliability. The positive micro–switching eliminates the
possibility of more than one circuit being in operation at any one time.
The design innovation of the Switch is the ‘sliding detent action’ which
obviates wave induced oscillation (common in mercury type switches)
while maintaining consistency in switching level accuracy.
The smooth robust ABS switch housing on the 9006 and 9010 models,
prevents adhesion of foreign materials.
Our extensive range of switches, cable types and cable lengths ensures we
have the ‘right’ product to suit the application.
Packaged Pump Stations
AUSTRALIA PTY LTD
FAX: (03) 9336 1099
EMAIL: sales@maxijet.com.au
REQUEST A QUOTATION
PIT SIZE
 MPPS100
(100 Ltr)
 MPPS200
(200
250 Ltr)
 MPPS900
(900 Ltr)
 MPPS1200
(1200 Ltr)
 MPPS3000
(3000 Ltr)
LID TYPE
 Class A poly Pedestrian
 Class B cast iron solid top (Light Duty)
 Class D cast iron solid top (Heavy Duty)
 Class B galvanised grate (Light Duty)
 Class D galvanised grate (Heavy Duty)
 Other __________________________________________
PUMP APPLICATION
 Single pump
 Dual pumps
 Stormwater
 Greywater
 Sewage
POWER SUPPLY
 1 Phase 240 volt
 3 Phase 415 volt
CONTROLLER TYPE
 Single pump controller  Dual pump controller
w/ high level alarm
w/ high level alarm
 High Level alarm only
FLOW REQUIREMENT
Litres / second @
metre lift
mm pipe size
metre head
metre run
COMMENTS