Contents English
Transcription
Contents English
KIMRAY Solutions Product Selection Guide Contents Pressure Regulators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Liquid Level Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Control Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Glycol Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Temperature Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 DE IN T U S A E ® H MA Relays, Pilots & Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . 6 NOTE: We reserve the right to modify or change, without prior notice, any statement or information contained herein. If exact dimensions or specifications are required by the customer certified prints will be furnished for a minimum charge upon request to KIMRAY, Inc. ® Copyright 2006, KIMRAY, Inc. ‡Configuration of Back Pressure Valve is a trademark of Kimray, Inc. KIMRAY Solutions Product Selection Guide NOTES: 1-1 ‡Configuration of Back Pressure Valve is a trademark of Kimray, Inc. Product Selection Guide Pressure Regulators Pressure Regulators Selection Guide 1-2 Contents Regulator Selection Guide Selection Guide...............................................................2 Regulators perform one of three functions: Back Pressure Regulators Up to 20 psi ....................................................................3 5 to 300 psi.....................................................................4 50 to 500 psi...................................................................5 5 to 1500 psi...................................................................6 Spring Operated 1 to 125 psi .........................................7 Back Pressure Regulator Maintains a constant upstream pressure. It limits upstream pressure by adjusting open to relieve excess pressure or conserves upstream pressure by adjusting closed to limit the flow to downstream. Pressure Reducing Regulators Max. Inlet Max. Outlet 175.............20 psi ......................................................8 300...........300 psi ......................................................9 500...........500 psi.....................................................10 4000.......1500 psi .....................................................11 Supply Gas Regulator 0 to 125 psi ..............................12 Differential Pressure Regulators 3 to 300 psi...................................................................13 High Pressure...............................................................14 Pressure Reducing Regulator Maintains a constant downstream pressure. It limits downstream pressure by adjusting closed to limit the flow to downstream or supports downstream pressure by adjusting open to allow additional flow from upstream. Differential Pressure Regulator Maintains a constant difference between upstream and downstream pressure. This difference in pressure may be maintained between the inlet and outlet of the regulator itself, or it may be maintained between the inlet and outlet of a separate device such as a flow meter. ‡® ‡® ‡® We start with Regulators because that’s where Kimray started. In 1948 Kimray introduced its first product - the 3” Pilot Operated Back Pressure Regulator. It was designed to provide a far superior alternative to the lever / weight operated and spring operated back pressure valves. IT TURNED OUT TO BE A VERY GOOD IDEA! ‡Configuration of Back Pressure Valve is a trademark of Kimray, Inc. Back Pressure Regulators Low Pressure and Vacuum Maintains constant upstream pressure. Limits upstream pressure by adjusting open to relieve excess pressure or conserves upstream pressure by adjusting closed to limit the flow to downstream. 1-3 Normal Service: Gaseous fluids Features: Intermittent-bleed pilot Soft seat for bubble tight shut-off High Capacity (full line size seat opening) Optional Spring Ranges: .5 oz. to 2.5 psig 1 oz. to 5 psig 1 psig to 20 psig Construction Materials: Ounces Back Pressure to Atmosphere OBPA Pressure Range: .5 oz. to 20 psig Maintains upstream pressure while flowing to positive downstream pressure. An outside source of instrument gas is required. The instrument gas pressure must be at least 60% of the maximum upstream pressure, or 10 psi; whichever is greater. Body Design Pressure Stem Plug Tubing Fittings Seat Diaphragms Cast Iron Scrd. 175 psi Flgd. 175 psi 303 Stainless Ductile Iron Copper Brass Nitrile Nitrile/Nylon Ductile Iron Scrd. 300 psi Flgd. 250 psi 303 Stainless Ductile Iron 304 Stainless Steel Polyurethane Nitrile/Nylon Steel Flgd. 285 psi 303 Stainless Steel 304 Stainless Steel Polyurethane Nitrile/Nylon Sizes available: Low Pressure Back Pressure BP Pressure Range: 3 to 20 psig Maintains upstream pressure while flowing to positive downstream pressure. An outside source of instrument gas is not required. Capacity will be somewhat diminished below 12 psi differential. 1” 2” 3” 4” 6” NPT NPT, Flanged, Grooved NPT, Flanged NPT, Flanged Flanged Normal Operating Temperature: -20o to 200o F Options: Ounces Back Pressure to Vacuum OBPV Pressure Range: .5 oz. to 20 psig Maintains upstream pressure while flowing to downstream vacuum. Plug Size: Reduced flow trim Elastomers: HSN, Viton®, Aflas® Trim Material: 316 Stainless Steel Tubing, Fittings, and internal exposed parts Installation: Normally horizontal Liquid Service: Vacuum Back Pressure to Vacuum VBPV Pressure Range: 1” TO 30” Hg Vacuum Maintains upstream vacuum while flowing to downstream vacuum. An outside source of instrument gas is required. The instrument gas pressure must be at least 60% of the maximum pressure differential, or 10 psi; whichever is greater. Most regulators can be modified for liquid service. An outside source of instrument gas is required. The instrument gas pressure must be at least 60% of the maximum upstream pressure or 10 psi; whichever is greater. Back Pressure Regulators 5 to 300 psig Controlled Pressure Maintains constant upstream pressure. Limits upstream pressure by adjusting open to relieve excess pressure or conserves upstream pressure by adjusting closed to limit the flow to downstream. ‡® 1-4 Normal Service: Gaseous fluids Features: Intermittent bleed pilot Soft seat for bubble tight shut-off High Capacity (full line size seat opening) Optional Springs: 125 psig Maximum 300 psig Maximum Construction Materials: Body Design Pressure Cast Iron Scrd. 175 psi Flgd. 175 psi Ductile Iron Scrd. 300 psi Flgd. 250 psi Steel Stem Plug Tubing Fittings Seat Diaphragms 303 Stainless Ductile Iron Copper Brass Nitrile Nitrile/Nylon 303 Stainless Ductile Iron 304 Stainless Steel Polyurethane Nitrile/Nylon 303 Stainless Steel 304 Stainless Steel Polyurethane Nitrile/Nylon Flgd. 285 psi Sizes available: 1” 2” 3” 4” 6” NPT NPT, Flanged, Grooved NPT, Flanged NPT, Flanged Flanged Normal Operating Temperature: -20o to 200o F Options: Plug Size: Reduced flow trim Elastomers: HSN, Viton®, Aflas® Trim Material: 316 Stainless Steel Tubing, Fittings, and internal exposed parts Installation: Normally horizontal Liquid Service: Most regulators can be modified for liquid service. An outside source of instrument gas is required. The instrument gas pressure must be at least 60% of the maximum upstream pressure or 10 psi; whichever is greater. Gas Back Pressure Regulator BP Pressure Range: 5 to 280 psig Maintains upstream pressure while flowing to positive downstream pressure. An outside source of instrument gas is not required. Capacity will be somewhat diminished below 12 psi differential. Non Venting Back Pressure Regulator BPNV Pressure Range: 5 to 280 psig Maintains upstream pressure while flowing to positive downstream pressure. An outside source of instrument gas is not required. No gas is vented to the atmosphere. Capacity will be somewhat diminished below 12 psi differential. Also known as a Self-contained Back Pressure Regulator. Liquid Back Pressure Regulator LBP Pressure Range: 5 to 280 psig Maintains upstream pressure while flowing to positive downstream pressure. Use for liquid back pressure control, or for installations where the media being regulated is not appropriate to be applied to the pilot. An outside source of instrument gas is required. The instrument gas pressure must be at least 60% of the maximum upstream pressure, or 10 psi; whichever is greater. ‡Configuration of Back Pressure Valve is a trademark of Kimray, Inc. Back Pressure Regulators 50 to 500 psig Controlled Pressure Normal Service: Gaseous fluids Features: Intermittent bleed pilot Soft seat for bubble tight shut-off High Capacity (full line size seat opening) 1-5 Spring Range: 50 to 500 psig Construction Materials: Body: Steel Stem: 303 Stainless Steel Plug: Steel Tubing: 304 Stainless Steel Fittings: Steel Seat: Nitrile Diaphragm: Nitrile Bellows: 3 ply Stainless Steel Sizes available: 2” NPT, Flanged Normal Operating Temperature: Gas Back Pressure Regulator BP -20o to 200o F Maintains constant upstream pressure. Options: Limits upstream pressure by adjusting open to relieve excess pressure or conserves upstream pressure by adjusting closed to limit the flow to downstream. Plug Size: Reduced flow trim Elastomers: HSN, Viton®, Aflas® Trim Material: 316 Stainless Steel Tubing, Fittings, and internal exposed parts The High Pressure Back Pressure Regulator is a versatile assembly of Kimray devices: 2” NPT or ANSI 300 RF Flanged Motor Valve Proportional pneumatic Pressure Pilot Instrument Gas Regulator Filter Drip Pot Steel tubing & fittings Installation: Horizontal WHY USE A PILOT OPERATED REGULATOR? Pressure regulators are commonly available in two types, the spring-operated regulator (sometimes called a direct-operated regulator) and a pilot-operated regulator. The spring operated regulator is very responsive, but it is not selected for its accuracy. As the flowing volume changes the set point changes, a pilot-operated regulator is selected because of its control accuracy. The pilot keeps the set point precisely constant with even large changes in flowing volume. Back Pressure Regulators 5 to1500 psig Controlled Pressure Maintains constant upstream pressure. Limits upstream pressure by adjusting open to relieve excess pressure or conserves upstream pressure by adjusting closed to limit the flow to downstream. 1-6 Pressure Pilot Supply Gas Regulator The High Pressure Back Pressure Regulator is a versatile assembly of Kimray devices: High Pressure Motor Valve 1”, 2”, 3”, 4”, 6” Proportional Pressure Pilot in three ranges: 5 to 280 psig 50 to 750 psig 125 to 1500 psig Instrument Gas Regulator Drip Pot Steel Tubing & Fittings Drip Pot Normal Operating Temperature: High Pressure Motor Valve -20o to 200o F Options: Plug Size: Reduced flow trim Elastomers: HSN, Viton®, Aflas® Trim Material: 316 Stainless Steel Tubing, Fittings, and internal exposed parts Construction Materials: Body Stem Cage Plug Tubing Standard Steel 303 Stainless Steel Carbide 304 Stainless Piston Balanced Steel 303 Stainless 316 Stainless D2 Tool Steel 304 Stainless Fittings Seat Steel D2 Tool Steel Steel D2 Tool Steel Plug Seal Metal-Metal Polyurethane Diaphragms Nitrile/Nylon Nitrile/Nylon High Pressure Back Pressure Regulator HPBP Standard Valve The “Standard Valve” is a smaller valve with reduced trim, ideal for pressure or flow control where a large valve is not required and would offer limited control for the volume being conducted. Trim Size: Connection: 1" NPT 1" 150-1500 4000 WP Flanged 1/4", 3/8",1/2" 2" NPT 1000 WP 2” NPT 2000 WP 2” NPT 4000 WP 2" 150-1500 Flanged 5/16", 5/8",7/8" Piston Balanced Valve VERSATILITY We have control valves with openings ranging from 1/4” to 6-3/4”. We have pressure pilots ranging from 1/2 oz. to 1500 psig controlled pressure. Put them together and you have an extremely wide selection of Regulators. The Piston Balanced Valve has a line- sized port for large capacity requirements. Its equal percentage trim makes it ideal for regulating pressure or flow rates. Connection: 2” NPT 1500 & 4000 WP 2" 150-1500 Flanged 3” 300 - 600 Flanged 4” 300 - 600 Flanged 6” 300 - 600 Flanged Trim Size: 1-1/2”, 2” 1-1/2”, 2” 2”, 3” 3”, 4” 6” Spring Loaded Back Pressure Regulators 1 to 125 psig Controlled Pressure Maintains constant upstream pressure. Control of the upstream pressure range of a liquid or gas system, such as treaters, free water knockouts, pressure vessels, vent lines on separators, flow treaters, compressor stations, metering runs, and gas gathering systems. Instrument gas is not required. Features: Single adjustment Single soft seat Removable valve seat 1-1/2” or 2” Inner Valve 6 Spring adjustment ranges: 1-1/2” Orifice 2” Orifice 0 to 10 psig 0 to 10 psig 10 to 25 psig 10 to 20 psig 20 to 40 psig 15 to 30 psig 40 to 65 psig 25 to 50 psig 65 to 90 psig 30 to 65 psig 80 to 125 psig 40 to 85 psig All internal parts can be removed with valve in line Body Materials Available: Cast Iron Ductile Iron Steel Size Available: 2” NPT, Flanged, Grooved Options: Plug Size: Reduced flow trim Elastomers: HSN, Viton®, Aflas® Six Spring Ranges Trim Material: 316 Stainless Steel Tubing, Fittings, and internal exposed parts Spring Loaded Back Pressure Regulator MT BP Need to control Back Pressure? but you have dirty, wet gas, or no instrument gas at all? Then this is the regulator for you! Spring operated-no gas required Minimal changes in setpoint High capacity Six spring ranges for precise control 1-7 Pressure Reducing Regulators Low Pressure and Vacuum Maintains constant downstream pressure. 1-8 Limits downstream pressure by adjusting closed to reduce the volume flowing to the outlet when downstream demand decreases, and opens to allow additional flow to downstream to maintain outlet pressure as downstream demand increases. Normal Service: Gaseous fluids Features: Intermittent bleed pilot Soft seat for bubble tight shut-off High Capacity (full line size seat opening) Optional Spring Ranges: .5 oz. to 2.5 psig 1 oz. to 5 psig 1 psig to 20 psig Construction Materials: Body Design Pressure Cast Iron Scrd. 175 psi Flgd. 175 psi Ductile Iron Scrd. 300 psi Flgd. 250 psi Steel Stem Plug Tubing Fittings Seat Diaphragms 303 Stainless Ductile Iron Copper Brass Nitrile Nitrile/Nylon 303 Stainless Ductile Iron 304 Stainless Steel Polyurethane Nitrile/Nylon 303 Stainless Steel 304 Stainless Steel Polyurethane Nitrile/Nylon Flgd. 285 psi Sizes available: 1” 2” 3” 4” 6” NPT NPT, Flanged, Grooved NPT, Flanged NPT, Flanged Flanged Normal Operating Temperature: Ounces Pressure Reducing OPR Pressure Range: .5 oz. to 20 psig Maintains positive downstream pressure. If upstream pressure is less than 10 psi an outside source of instrument gas is required. The instrument gas pressure must be at least 60% of the maximum upstream pressure, or 10 psi; whichever is greater. Ounces Pressure Reducing Vacuum OPRV Pressure Range: 1” to 30” Hg Vacuum Maintains downstream vacuum. If upstream pressure is less than 10 psi an outside source of instrument gas is required. The instrument gas pressure must be at least 60% of the maximum differential pressure, or 10 psi; whichever is greater. -20o to 200o F Options: Plug Size: Reduced flow trim Elastomers: HSN, Viton®, Aflas® Trim Material: 316 Stainless Steel Tubing, Fittings, and internal exposed parts Installation: Normally horizontal Liquid Service: Most regulators can be modified for liquid service. An outside source of instrument gas is required. The instrument gas pressure must be at least 60% of the maximum upstream pressure or 10 psi; whichever is greater. What size valve do I need. You can calculate valve flow rates and sizes online at our web site. www.kimray.com No downloading is necessary. Pressure Reducing Regulators 5 to 280 psig Controlled Pressure Maintains constant downstream pressure. ‡® Limits downstream pressure by adjusting closed to reduce the volume flowing to the outlet when downstream demand decreases, and opens to allow additional flow to downstream to maintain outlet pressure as downstream demand increases. Normal Service: Gaseous fluids Features: Intermittent bleed pilot Soft seat for bubble tight shut-off High Capacity (full line size seat opening) Optional Springs: 125 psig Maximum 300 psig Maximum Construction Materials: Pressure Reducing Regulator PR Pressure Range: 5 to 280 psig Maintains positive downstream pressure. An outside source of instrument gas is not required. Non Venting Pressure Reducing Regulator PR-NV Body Design Pressure Cast Iron Scrd. 175 psi Flgd. 175 psi Ductile Iron Scrd. 300 psi Flgd. 250 psi Steel Stem Plug Tubing Fittings Seat Diaphragms 303 Stainless Ductile Iron Copper Brass Nitrile Nitrile/Nylon 303 Stainless Ductile Iron 304 Stainless Steel Polyurethane Nitrile/Nylon 303 Stainless Steel 304 Stainless Steel Polyurethane Nitrile/Nylon Flgd. 285 psi Pressure Range: 5 to 280 psig Maintains positive downstream pressure. An outside source of instrument gas is not required. No gas is vented to the atmosphere. Capacity will be somewhat diminished below 12 psi differential. Also known as a Self-contained Pressure Reducing Regulator. Pressure Reducing Balanced Regulator PRB Pressure Range: 5 to 280 psig Maintains positive downstream pressure. An outside source of instrument gas is not required. Recommended where the pressure to the regulator varies more than 2:1, and regulated pressure must be kept to within 2 psi of the desired set point. Sizes available: 1” 2” 3” 4” 6” NPT NPT, Flanged, Grooved NPT, Flanged NPT, Flanged Flanged Normal Operating Temperature: -20o to 200o F Options: Plug Size: Reduced flow trim Elastomers: HSN, Viton®, Aflas® Trim Material: 316 Stainless Steel Tubing, Fittings, and internal exposed parts Installation: Normally horizontal DID YOU KNOW? The same parts and repair kits which are used in today’s regulators will fit in our 1948 models, too! ‡Configuration of Back Pressure Valve is a trademark of Kimray, Inc. Liquid Service: Most regulators can be modified for liquid service. An outside source of instrument gas is required. The instrument gas pressure must be at least 60% of the maximum upstream pressure or 10 psi; whichever is greater. 1-9 Pressure Reducing Regulators 50 to 500 psig Controlled Pressure Maintains constant downstream pressure. 1-10 Limits downstream pressure by adjusting closed to reduce the volume flowing to the outlet when downstream demand decreases, and opens to allow additional flow to downstream to maintain outlet pressure as downstream demand increases. Normal Service: Gaseous fluids Features: Intermittent bleed pilot Soft seat for bubble tight shut-off High Capacity (full line size seat opening) Spring Range: 50 to 500 psig Construction Materials: Body: Steel Stem: 303 Stainless Steel Plug: Steel Tubing: 304 Stainless Steel Fittings: Steel Seat: Nitrile Diaphragm: Nitrile Bellows: 3 ply Stainless Steel Pressure Reducing Regulator PR Sizes available: 2” NPT, Flanged Normal Operating Temperature: -20o to 200o F Options: Plug Size: Reduced flow trim Elastomers: HSN, Viton®, Aflas® Trim Material: 316 Stainless Steel Tubing, Fittings, and internal exposed parts Installation: Horizontal Maintains constant downstream pressure. Limits downstream pressure by adjusting closed to reduce the volume flowing to the outlet when downstream demand decreases, and opens to allow additional flow to downstream to maintain outlet pressure as downstream demand increases. The High Pressure Pressure Reducing Regulator is a versatile assembly of Kimray devices: 2” NPT or ANSI 300 RF Flanged Motor Valve Proportional pneumatic Pressure Pilot Instrument Gas Regulator Filter Drip Pot Steel tubing & fittings WHY USE A PILOT OPERATED REGULATOR? Pressure regulators are commonly available in two types, the spring-operated regulator (sometimes called a direct-operated regulator) and a pilot-operated regulator. The spring operated regulator is very responsive, but it is not selected for its accuracy. As the flowing volume changes the set point changes. A pilot-operated regulator is selected because of its control accuracy. The pilot keeps the set point precisely constant with even large changes in flowing volume. Pressure Reducing Regulators 5 to 1500 psig Controlled Pressure Pressure Pilot Supply Gas Regulator Maintains constant downstream pressure. Limits downstream pressure by adjusting closed to reduce the volume flowing to the outlet when downstream demand decreases, and opens to allow additional flow to downstream to maintain outlet pressure as downstream demand increases. 1-11 The High Pressure Pressure Reducing Regulator is a versatile assembly of Kimray devices: Drip Pot High Pressure Motor Valve 1”, 2”, 3”, 4”, 6” Proportional Pressure Pilot in three ranges: 5 to 280 psig 50 to 750 psig 125 to 1500 psig Instrument Gas Regulator Drip Pot Steel Tubing & Fittings Normal Operating Temperature: High Pressure Motor Valve -20o to 200o F Options: High Pressure Pressure Reducing Regulator Standard Valve The “Standard Valve” is a smaller valve with reduced trim, ideal for pressure or flow control where a large valve is not required and would offer limited control for the volume being conducted. Connection: 1" NPT 1" 150-1500 Construction Materials: Trim Size: 4000 WP Flanged 2" NPT 1000 WP 2” NPT 2000 WP 2” NPT 4000 WP 2" 150-1500 Flanged Plug Size: Reduced flow trim Elastomers: HSN, Viton®, Aflas® Trim Material: 316 Stainless Steel Tubing, Fittings, and internal exposed parts 1/4", 3/8",1/2" 5/16", 5/8",7/8" Body Stem Cage Plug Tubing Standard Steel 303 Stainless Steel Carbide 304 Stainless Piston Balanced Steel 303 Stainless 316 Stainless D2 Tool Steel 304 Stainless Fittings Seat Steel D2 Tool Steel Steel D2 Tool Steel Plug Seal Metal-Metal Polyurethane Diaphragms Nitrile/Nylon Nitrile/Nylon Piston Balanced Valve The Piston Balanced Valve has a line- sized port for large capacity requirements. Its equal percentage trim makes it ideal for regulating pressure or flow rates. Connection: 2” NPT 1500 & 4000 WP 2" 150-1500 Flanged 3” 300 - 600 Flanged 4” 300 - 600 Flanged 6” 300 - 600 Flanged They may look a bit complicated, but these regulators are extremely versatile. With the right combination of Pilot and Control Valve you can have a regulator for Trim Size: 1-1/2”, 2” 1-1/2”, 2” 2”, 3” 3”, 4” 6” JUST ABOUT ANY APPLICATION. Pressure Reducing Regulators 5 to 125 psig Controlled Pressure Maintains constant downstream pressure. Provides a supply of constant reduced pressure for pneumatic instruments and pilot operated controllers. Features: Easily adjusted Internally relieving Available in Aluminum and 316 Stainless Steel Connections: Inlet and Outlet - 1/4” NPT Operating Temperature: 0o to 200oF (-18oC to 93oC) Maximum Inlet Pressure: 4000 psi Outlet Pressure: 0 to 125 psi Construction Materials: Body: Aluminum or 316 Stainless Steel Diaphragm: Polyurethane Seat: Nylon Supply Gas Regulator SGR Performance Curves Output Pressure psig 1-12 30 28 1500 psig 26 100 psig 250 psig 100 200 300 400 500 600 700 500 psig 800 900 1000 1100 Standard Cubic Feet per Hour : Air* Initial set point at 30 psig at 120 SCFH. Inlet pressure indicated on each curve. *For capacities in SCFH of gas at .65 specific gravity multiply fow rate by 1.24 We didn’t want to make just another supply gas regulator. So how is it better than the others? But when our customers said we don't want another regulator; we want a better one, we made one. Well, one of the problems with supply gas regulators is that the output pressure "droops" with large changes in flow rate or large changes in upstream pressure. Kimray's is better because it has less "droop" than any of the other popular brands. Pressure Differential Regulators 5 to 300 psig Controlled Pressure ‡® Maintains constant differential pressure between upstream and downstream. Any change in downstream pressure will cause a repositioning of the stem assembly until a like change in upstream pressure ocurrs to maintain the set differential pressure. Normal Service: Gaseous fluids Features: Intermittent bleed pilot Soft seat for bubble tight shut-off High Capacity (full line size seat opening) Optional Springs: 125 psig Maximum 300 psig Maximum Construction Materials: Pressure Differential Regulator PD Pressure Range: 5 to 280 psig Maintains a constant pressure differential between its own upstream and downstream connections. If the difference between upstream and downstream pressures is too low, the valve will close slightly to increase the differential. Upstream Differential Pressure Regulator USDP Pressure Range: 5 to 280 psig Maintains a constant pressure differential across another device within the same flowing system. If the difference between the upstream and downstream pressures acting upon the meter or meter run being monitored is too low, the valve will open slightly, increasing the flow rate which results in an increase in the differential. Body Design Pressure Cast Iron Scrd. 175 psi Flgd. 175 psi Ductile Iron Scrd. 300 psi Flgd. 250 psi Steel Stem Plug Tubing Fittings Seat Diaphragms 303 Stainless Ductile Iron Copper Brass Nitrile Nitrile/Nylon 303 Stainless Ductile Iron 304 Stainless Steel Polyurethane Nitrile/Nylon 303 Stainless Steel 304 Stainless Steel Polyurethane Nitrile/Nylon Flgd. 285 psi Sizes available: 1” 2” 3” 4” 6” NPT NPT, Flanged, Grooved NPT, Flanged NPT, Flanged Flanged Normal Operating Temperature: -20o to 200o F Options: Plug Size: Reduced flow trim Elastomers: HSN, Viton®, Aflas® Trim Material: 316 Stainless Steel Tubing, Fittings, and internal exposed parts Installation: Normally horizontal ‡® ‡Configuration of Back Pressure Valve is a trademark of Kimray, Inc. Liquid Service: Most regulators can be modified for liquid service. An outside source of instrument gas is required. The instrument gas pressure must be at least 60% of the maximum upstream pressure or 10 psi; whichever is greater. 1-13 Pressure Differential Regulators Up to 4000 psig Static Pressure 1-14 Pressure Differential Controller PDC Controlled Pressure Differential Range: 1 to 260 inches H2O A Pressure Differential Regulator can be assembled using the following Kimray devices: High Pressure Motor Valve 1”-6” Pressure Differential Controller: 100 PDC for 1000 psi max. static pressure 200 PDC for 2000 psi max. static pressure 400 PDC for 4000 psi max. static pressure Instrument Gas Regulator Drip Pot Steel Tubing & Fittings Maintains a constant pressure differential across another device within the same flowing system. The “PDC” Series Pressure Differential Controller connects across the orifice plate of a meter run to maintain a constant stable pressure differential across the meter run. This relates to a constant flow rate when the upstream or downstream pressure is constant. The pilot adjusts the flow rate to maintain the pressure differential by positioning a pressure opening motor valve with equal percentage valve trim for precise flow control. Applications: Precise gas flow rate for gas lift. Better charts and measurement on meter runs. Stabilizes gas flow for better well production. Differential limiting for reducing “off chart” conditions. Features: Intermittent bleed construction Throttle operation 1 to 260 inches of water differential pressure Heavier spring available (425” H2O) Pilot may be used with many types of diaphragm motor valves SOMETIMES YOU JUST HAVE TO GIVE UP AND ADMIT SUCCESS! The PDC originially started life as an obscure liquid level control pilot before a very creative fellow at Kimray converted one into a Pressure Differential Control. It became one of our top 10 sellers before we had even put it in our catalog! 2-1 Product Selection Guide Liquid Level Controls Liquid Level Controls Selection Guide Contents Liquid Level Controls Selection Guide ...................2 Mechanical Float / Lever Operated ..........................................3 Trunnions ...............................................................4 Mechanical Pilots & Closures ................................5 Weight Operated ....................................................6 Liquid Level Controls Selection Guide Mechanical For control of liquid level. No instrument gas is required. 2-2 Pneumatic Float Operated Gen 2 Liquid Interface or Top Level Control...........7 Top Level Control....................................................8 Liquid Interface Control ..........................................8 Pneumatic Float Operated Snap or throttle action liquid level controller. Instrument gas required. Pneumatic Floatless Low Pressure .........................................................9 High Pressure.......................................................10 Pneumatic Floatless Differential pilots designed to signal on a set difference between separator gas pressure and separator fluid pressure. Electric Float Operated Electric..................................................................10 Electric Float Operated Electronically sense a specific liquid level in a vessel. Have you seen it? The new GEN II Liquid Level Controller See it on page 2-7 There is nothing else like it! Mechanical Control Valves Float / Lever Operated Normal Service: Liquids ‡® Features: Quick opening trim Balanced single seat Teflon packed rotary stuffing box Soft seat for bubble tight shut-off Available in Angle or Through Body Construction Materials: Diaphragm Balanced Mechanical Valves ‡® Balancing Diaphragm Allows the valve to shut against full rated upstream pressure.. Body Stem Plug Cage Disc Seat Cast Iron 303 Stainless Ductile Iron Ductile Iron Ductile Iron Nitrile Diaphragm Nitrile/Nylon Stuffing Box Brass Packing Nitrile Ductile Iron 303 Stainless Ductile Iron Ductile Iron Ductile Iron Polyurethane Nitrile/Nylon Brass Nitrile Steel 303 Stainless Steel Ductile Iron Ductile Iron Polyurethane Nitrile/Nylon Brass Nitrile Sizes available: 2” 3” 4” 6” Maximum Operating Pressure NPT Flanged 2” 3-4” 2” 3-4” 6” Cast Iron 125 125 125 125 Ductile Iron 250 125 250 125 125 Steel Normal Operating Temperature: -20o to 200o F 250 125 125 Options: Elastomers: HSN, Viton®, Aflas® Trim Material: 316 Stainless Steel internal parts Installation: Piston Balanced Mechanical Valves ‡® NPT, Flanged NPT, Flanged Flanged Flanged Any position Balancing Piston Same balancing action as with the Diaphragm Balanced Valve. Used for higher pressures. SPEAKING OF SIMPLICITY: Maximum Operating Pressure NPT Flanged 2” 3-4” 2” 3-4” Cast Iron 125 125 Ductile Iron 500 250 250 250 Steel 285 285 ‡Configuration of Mechanical Oil Valve is a trademark of Kimray, Inc. Our mechanical control valve may not look that special, but it sure has been copied a lot! A simple thing that works well-it’s no mystery that it has been imitated so much. 2-3 Mechanical Liquid Level Control Trunnion Assemblies Normal Service: Liquids Features: Teflon packed rotary stuffing box 303 Stainless steel shaft Stainless steel adjustable linkage 3/4” float arm hub TANK SHUT OFF INSTALLATION 8” Hammer Union Trunnion Assembly HUTA 2-4 Style Material Max. W.P. One Piece Single End Shaft Two Piece Single End Shaft Two Piece Double End Shaft Ductile Iron Ductile Iron Ductile Iron 250 psi 250 psi 500 psi Float Cover & Trunnion Assembly MECHANICAL DUMP INSTALLATION Material: Ductile Iron Opening Size: 6”, 8”, 10” Working Pressure: 250 psi Trunnion Assembly Style ‡Configuration of Mechanical Oil Valve is a trademark of Kimray, Inc. TO-D Material Max. W.P. TOB Bolt-On Single End Shaft Bolt-On Double End Shaft Ductile Iron 250 psi Ductile Iron 500 psi Weld-On Double End Shaft Steel 500 psi Mechanical Liquid Level Control Mechanical Pilots & Hammer Union Closures Application: For converting the mechanical input of a float operated trunnion into a pneumatic output for a diaphragm operated dump valve. Supply Pressure: 5 to 30 psi Material: Cast Iron 2-5 Mechanical Pilot 3 PM Hammer Union Closures HUC Application: Used as an access opening for pressure vessels Features: SA-106 Grade B/C pipe Heat specifications available for code purposes Standard ACME thread for easy access O-Ring seal (Nitrile) Features: Available Sizes: Direct float operated Snap or throttle action Field reversible Controls motor valve requiring up to 30 psi diaphragm pressure 4” 5” 6” 8” Bistable Mechanical Pilot - 500 psi, 1500 psi 1000 psi, 1500 psi 1000 psi, 1500 psi 600 psi, 1000 psi, 1500 psi 3 PMB What is a TRUNNION? The dictionary says it is “a pivot on which something can be rotated” What is a HUTA? Hammer Union Trunnion Assembly A trunnion connected to a vessel using a hammer union. Features: Direct float operated Snap action Direct or indirect Controls any motor valve requiring up to 30 psi diaphragm pressure Wide span adjustment What is a BISTABLE PILOT? A pilot or relay which stays OFF until it is turned ON, and stays ON until it is turned OFF. Mechanical Liquid Level Control Weight Operated Normal Service: As oil or water valve for treaters, water knockouts and gunbarrels. For pressure, atmospheric, or vacuum operation. For discharging salt water to disposal systems. ‡® Features: 2-6 Soft seat for tight shut-off Balanced against upstream pressure Balanced against downstream pressure or vacuum Standard weight and lever holds approx. 4’ head Weights may be added to increase liquid head Can be manually opened and closed Sample tap on inlet connnection Rotary stuffing box with Teflon packing All interior parts can be removed without taking valve out of line Prevents air from entering salt water disposal system piping Treater Valve WA Balancing Diaphragm Allows the valve to shut against full rated upstream pressure or vacuum. Construction Materials: Body Shaft Plug Cage Disc Seat Diaphragms StuffingBox Packing Cast Iron 303 Stainless Gray Iron Gray Iron Ductile Iron Nitrile Nitrile/Nylon Brass Nitrile Ductile Iron 303 Stainless Gray Iron Gray Iron Ductile Iron Nitrile Nitrile/Nylon Brass Nitrile Sizes available: 2” 3” 4” 6” ‡® Steel 303 Stainless Steel Gray Iron Ductile Iron Nitrile Nitrile/Nylon Brass Nitrile NPT, Flanged Flanged Flanged Flanged Normal Operating Temperature: -20o to 200o F Options: Maximum Operating Pressure NPT Flanged 2” 2” 3” 4” 6” Cast Iron Ductile Iron Steel 125 60 60 60 60 125 125 125 125 INSTALLATION Elastomers: HSN, Viton®, Aflas® Trim Material: 316 Stainless Steel internal parts Installation: Horizontal TREATER VALVE that’s what we call it. One of Kimray’s first products,the Treater Valve is still widely used today. We think that’s because our engineers keep saying, “Keep it SIMPLE Build it RUGGED Make it DEPENDABLE.” ‡Configuration of Water Valve is a trademark of Kimray, Inc. 125 GEN 2 Liquid Level Controller Float Operated Features: Low Friction Waggle Arm: no rotating stuffing box and related friction/stiction Snap or Throttle control in one pilot: simple adjustment to change from snap to throttle control with the turn of a knob. Intermittent-Bleed Pilots Built-in supply filter 2-7 Vented Case: 1/4” NPT tapped vent is easy to connect and pipe exhaust away if needed Side or Back Connections: Back and side NPT connections for instrument supply and output Installation: 4 SIMPLE STEPS √ Hook it up √ Select snap or throttle √ Set liquid level √ Go home! Specifications: Applications: Used on oilfield scrubbers and separators Supply Pressure: 0-35 psig maximum Vessel Operating Pressure: 50 to 4000 psig maximum Temperature Range: -20 to 200°F (optional elastomers provide higher maximum temperature) Float Travel: 3/4” maximum Liquid Level Controls Float Operated Pneumatic Level Control Universal Level Control Features: Direct acting Intermittent bleed pilot Simple installation Easy to use No adjustment required .65 specific gravity or higher 2-8 Bodies Available: 1” 1” 1” 2” 2” NPT Brass NPT Steel NPT Stainless Steel NPT Steel NPT Stainless Steel Maximum W.P.: 1500 psig Supply Pressure: 30 psig max. Maximum Temperature: 200oF Options: Low density, high temperature float Electric Level Switches ULC Horizontal Electronic Level Switch HELS Maximum Working Pressures: 5,000 psig polypropylene float 2,000 psig stainless steel float 2,000 psig manual override Features: 316 SS Wetted Parts Sealed Hermetic Reed Switch SPDT Reed Switch (50 Vdc, 2 A/120Vac, .83A) CSA Certificate #1662451, USA and Canada Expl. Proof – Class I, Groups A,B,C,D Class II, Groups E,F,G, Class III Class I, Zone 1, AExdIIC, ExdIIC (Stainless steel float only) Additonal seal not required NEMA4X Available with manual override for testing. Minimum Specific Gravity 0.4. Temperature Range: Temp: - 40F to 400F Vertical float adapter Connections: 1 1/2" NPT 2" NPT Body Material: Stainless Steel Vertical Electronic Level Switch Working Pressure: 300 psig maximum Contact Ratings: 3 Watts Maximum 0.25 Amps Maximum 120 VAC 5 VA 175 DC Maximum Connections: 1 1/2” NPT 2” NPT Body Material: Stainless Steel VELS Pneumatic Liquid Level Controls Floatless - Low Pressure Floatless Liquid Level Controller 12PL Control Range: Up to 4 feet max. liquid level height with standard spring Optional springs provide 8 ft. and 30 ft. maximums Use with: Indirect Differential Pilot 12PDS 2-9 Control Range: Kimray MT series valves or pressure closing valves which use full separator pressure on the valve diaphragm. Up to 36 in. max. liquid level height with standard spring Optional spring provides 100 in. maximum Features: Use with: Kimray Balanced series “PC“ valves or pressure closing valves which use 5 to 30 psig on the valve diaphragm. No float required Easily installed Intermittent bleed pilot Throttling or semi-snap control Only one adjustment for changing control Only one adjustment for changing liquid level Features: Body Materials Available: Cast iron, Ductile iron, Steel Working Pressure: 125 psig max. Supply Pressure: Pilot uses separator gas equalizing line for supply. Indirect acting for Pressure Closing Motor Valves Throttle control Floatless operation for liquid level control Uses separate adjustable supply gas pressure One adjustment for changing sensitivity One adjustment for changing liquid level Body Material: Cast iron Working Pressure: 125 psig max. Supply Pressure: 5 to 30 psig Maximum Temperature: 200oF Maximum Temperature: 200oF Direct Differential Pilot 12PDSS Control Range: Floatless Liquid Level Controllers: Max. Liq. Direct Use with Snap Supply Level Valve Source Height Throttle Indirect Action 4 ft. std. Snap Pressure 12 PL Separator Indirect Optional or Closing Throttle 8ft/30ft 36” std. Instrmnt 12 PDS Optional Indirect Pressure Throttle Closing Gas 100” Pilot 12 PDSS 36” std. Optional 100” Direct Pressure Opening Snap Instrmnt Gas Up to 36 in. max. liquid level height with standard spring Optional spring provides 100 in. maximum Use with: Kimray Balanced series “PO“ valves or pressure opening valves which use 5 to 30 psig on the valve diaphragm. Features: Direct acting for Pressure Opening Motor Valves Adjustable spread in liquid level of 6 to 12 inches Floatless operation for liquid level control Uses separate adjustable supply gas pressure One adjustment for changing sensitivity One adjustment for changing liquid level Body Material: Cast iron Working Pressure: 125 psig max. Supply Pressure: 5 to 30 psig Maximum Temperature: 200oF Liquid Level Controls GEN II Liquid Level Controller Floatless Liquid Level Controllers Control Range: 12 - 15 inches max. liquid level height with standard spring Optional springs provide 3 - 4 foot maximums Use with: Kimray “PO” High Pressure Motor Valves or pressure opening valves which use 5 to 30 psig on the valve diaphragm Specially designed for inlet gas scrubbers on compressors 2-10 Features: No float required Intermittent bleed pilot Snap control Low friction waggle arm Pilots are furnished with high pressure equalizer drip pot, low pressure supply drip pot, one gas supply regulator, tubing and fittings for normal installation Body Material: Steel Working Pressure: 1000, 2000 or 4000 psig Supply Pressure: 5 to 30 psig Floatless Liquid Level Controller S P E T S E L P M 4 SI PLC √ Hook it up √ Select snap or throttle √ Set liquid level Specially designed for inlet gas scrubbers on compressors Snap control Built-in snubber reduces effects of pressure pulsations One adjustment for changing liquid level 4 - 7 inch span with standard spring √ Go home! Reversable Floatless Liquid Level Controller RPLC Still don't know which level control is the best for your application? Well, don't make ulp your mind until you check out Kimray's newest, simplest, most versatile, most accurate, best priced GEN II Liquid Level Controller Snap or throttle operation May be used with Pressure Opening or Pressure Closing motor valves (see page 2-7 in this catalog) 3-1 Product Selection Guide Control Valves Control Valves Selection Guide Contents Valve SelectionGuide..............................................2 Valve Selection Guide Diaphragm Operated Diaphragm Operated On / Off Control Valves Up to 400 psi ............................................3 Up to 4000 psi..........................................4 Throttle Control Valves Low Pressure............................................5 Up to 400 psi ............................................6 Up to 4000 psi ..........................................7 Actuators ..................................................9 Three - Way..........................................................10 On / Off Control Valves Fully open or fully closed, the valve is designed to permit maximum flow or no flow at all. Almost any control valve can be used for On / Off service, but some valves are designed exclusively for such applications and are the ones listed in this section. The most common applications are as Dump Valves or Shut-Down Valves. Throttle Control Valves The plug in the valve is designed for proportional control of flow. The most common application is as a regulator of flow, pressure, liquid level, or temperature. Three-Way Control Valves Divert flow from inlet to either of two outlets, or mix the flow from two inlets to a common outlet. 3-2 Mechanical Mechanical Float / Lever Operated.........................................11 Trunnions..............................................................12 Weight Operated...................................................13 Electric..................................................................14 For control of liquid level. No instrument gas is required. Metering Metering Manually Operated Metering................................14 Manually operated, choke-type valve. Which one’s the dump v alve? Actually alm o st all of th em could be That’s why dump valves this is calle . d the “sele ction guide tried to pre ”. We have sent this se ction as sim can, so that ply and clea you can tell rly as we one valve fr have trouble om another call us. We . If you ’ll not only h right valve, e lp you find th we’ll even r e ewrite this catalog if w e need to! Diaphragm Operated Control Valves On / Off Service - Low Pressure Normal Service: Liquids Features: Quick opening trim Balanced single seat 10 psi minimum diaphragm pressure Soft seat for bubble tight shut-off Available in Pressure Opening or Pressure Closing Available in Angle or Through Body Special stem seal requires no lubrication Construction Materials: Pressure Opening Pressure Closing Diaphragm Balanced Motor Valves Actuator Diaphragm Balancing Diaphragm Allows the valve to shut against full rated upstream pressure, while being able to be actuated with as little as 10 psi Actuator Diaphragam pressure. Body Stem Plug Cage Disc Seat Diaphragms Cast Iron 303 Stainless Ductile Iron Ductile Iron Ductile Iron Nitrile Nitrile/Nylon Ductile Iron 303 Stainless Ductile Iron Ductile Iron Ductile Iron Polyurethane Nitrile/Nylon Steel 303 Stainless Steel Ductile Iron Ductile Iron Polyurethane Nitrile/Nylon 3-3 Sizes available: 2” 3” 4” 6” NPT, Flanged NPT, Flanged Flanged Flanged Normal Operating Temperature: -20o to 200o F Maximum Operating Pressure Cast Iron Ductile Iron Steel Options: NPT 2” 3-4” 125 125 125 125 Elastomers: HSN, Viton®, Aflas® Trim Material: 316 Stainless Steel internal parts Flanged 2” 3-4” 6” 125 125 125 125 125 Installation: 125 Any position Piston Balanced Motor Valves Actuator Diaphragm Balancing Piston Same balancing action as with the Diaphragm Balanced Valve. Used for higher pressures. Maximum Operating Pressure Cast Iron Ductile Iron NPT 2” 3-4” 125 125 400 250 Flanged 2” 3-4” 125 125 250 250 Steel 285 285 t! Yep! h g i r e re r ’ a u o y Y all e r se e h s! T e v l va p dum Diaphragm Operated Control Valves On / Off Service - High Pressure ‡® Normal Service: Liquids Features: Quick opening trim Single seat Travel indicator Available in Pressure Opening or Pressure Closing Field reversible actuator Teflon packed stuffing box requires no lubrication Open yoke design - accurate travel indication - complete isolation of actuator High Pressure Motor Valve HIGH CAPACITY - LOW DIFFERENTIAL PRESSURE SOFT SEAT TRIM For increased capacity Uses standard valve body Teflon seal 300 psi max. pressure differential On / Off service Construction Materials: 3-4 Valve High Pressure Motor Valve Non-Freeze High Pressure Dump Body Stem Plug Cage Actuator Seat Diaphragms Steel 303 Stainless 303 Stainless Steel Ductile Iron Steel Nitrile/Nylon Steel 303 Stainless Carbide Steel Ductile Iron D2 Steel or Carbide Nitrile/Nylon Valve Connection 1” Orifice 15/16” 2” 1-1/2” Cv 12.0 31.2 HIGH WEAR RESISTANCE - HIGH DIFFERENTIAL PRESSURE CARBIDE TRIM High Pressure Motor Valve Sizes available: For increased wear resistance Uses standard valve body Carbide trim Ideal for high pressure differential On / Off service 1” NPT, Flanged - Angle or Through Body 2” NPT, Flanged - Angle or Through Body Non-Freeze Motor Valve Size available: Valve Connection 1” NPT Inlet & Outlet 2” Vessel Mounting 1” Maximum Working Pressure: 4000 psi Normal Operating Temperature: -20o to 200o F 2” Available Orifice Sizes 1/8”, 3/16”, 1/4”, 3/8” 1/4”, 3/8”, 1/2”, 3/4”, 1” Non-Freeze High Pressure Dump Valve- Carbide Trim HIGH WEAR RESISTANCE - HIGH DIFFERENTIAL PRESSURE The Non-Freeze Dump Valve places the trim inside the vessel in direct contact with the process liquid, preventing freezing within the valve. Options: Elastomers: HSN, Viton®, Aflas® Trim Material: 316 Stainless Steel internal parts Carbide, 17-4 PH Stainless Valve Available Carbide Connection Orifice Sizes 1” Inlet & Outlet 1/4”, 3/8”, 1/2” 2” Vessel Mounting Installation: Any position SMS Standard actuator has an effective diaphragm area of 30 square inches. 65 Topworks has an effective area of 65 square inches, which allows a wider adjustable spring range. Uh hu h! dump valves ! Maximum Pressure Drop: SMS - 1/4” - 2000 psi 3/8” - 800 psi 1/2” - 450 psi 65 SMS - 1/4”, 3/8”, 1/2” - 4000 psi 65 SMS ‡ Configuration of High Pressure Motor Valve is a trademark of Kimray, Inc. Diaphragm Operated Control Valves Throttle Service - Low Pressure Low Pressure Motor Valves MT & DA Normal Service: Commonly used for liquid dump or burner valves Features: Equal Percentage trim Single seat Soft seat for bubble tight shut-off Available in Pressure Opening or Pressure Closing Construction Materials: Pressure Closing “MT” Pressure Opening “DA” Maximum Controlled Pressure: Actuation Pressure Closing Orifice Line Size Reduced Port Valve Size 1” - 6” 1” 2” - 6” Controlled Pressure 2 X Signal Pressure 8 X Signal Pressure 5 X Signal Pressure Line Size 1” 2” - 4” 6” 10 psi 22 psi 5 psi Reduced Port 1” 2” - 4” 6” 35 psi 44 psi 12 psi Pressure Opening Low Pressure Adjustable Motor Valves Body Design Pressure Cast Iron Scrd. 175 psi Flgd. 175 psi Ductile Iron Scrd. 300 psi Flgd. 250 psi Steel Stem Plug Seat Diaphragms 303 Stainless Ductile Iron Nitrile Nitrile/Nylon 303 Stainless Ductile Iron Polyurethane Nitrile/Nylon 303 Stainless Steel Polyurethane Nitrile/Nylon Flgd. 285 psi Sizes available: MT & DA: 1” NPT 2” NPT, Flanged 3” NPT, Flanged 4” Flanged 6” Flanged ADA: 1” NPT 2” NPT, Flanged ADA Normal Operating Temperature: -20o to 200o F Options: Elastomers: HSN, Viton®, Aflas® Trim Material: 316 Stainless Steel internal parts Orifice Size: LIne size or reduced Installation: Normally horizontal DOING THINGS WELL: Our sales and technical people often recommend competitor’s products! Maximum Controlled Pressure: Actuation Orifice Pressure Line Size Valve Size 1” 2” Reduced Port 1” Opening Controlled Pressure 40 psi 250 psi 80 psi Why? We realize that we can’t do everything, so we try to limit our efforts so that what we do -- we do well! 3-5 Diaphragm Operated Control Valves Balanced Throttle Service - Low Pressure Normal Service: Liquids or Gas Features: Equal Percentage trim for throttling service Can be used for on / off service Shut off at full rated upstream pressure Full line size port for high capacity Balanced single seat 30 psi maximum required diaphragm pressure Soft seat for bubble tight shut-off Available in Pressure Opening or Pressure Closing Available in Through Body Special stem seal requires no lubrication Construction Materials: 3-6 Body Stem Plug Piston Cylinder Seat Diaphragms Cast Iron 303 Stainless Ductile Iron 303 Stainless 303 Stainless Nitrile Nitrile/Nylon Ductile Iron 303 Stainless Ductile Iron 303 Stainless 303 Stainless Polyurethane Nitrile/Nylon Steel 303 Stainless Steel 303 Stainless 303 Stainless Polyurethane Nitrile/Nylon Sizes available: 2” NPT, Flanged 3” NPT, Flanged 4” Flanged Pressure Opening Pressure Closing Piston Balanced Throttling Motor Valves Cast Iron Ductile Iron NPT 2” 3-4” 125 125 400 250 Flanged 2” 3-4” 125 125 250 250 Normal Operating Temperature: -20o to 200o F Options: Elastomers: HSN, Viton®, Aflas® Trim Material: 316 Stainless Steel internal parts Installation: Normally horizontal ARE THESE DUMPVALVES? Although the Piston Balanced Throttling Valves were designed for throttling service, they have great capacity and work well for liquid dump service. Diaphragm Pressure Upstream Pressure Downstream Pressure PBT Steel 285 285 Diaphragm Operated Control Valves Throttle Service - High Pressure Normal Service: Liquids or Gas High Pressure Motor Valve Features: ‡® Equal Percentage trim for throttling service Nominal semi-linear trim for liquid throttling service Can be used for on / off service Single seat Travel indicator Available in Pressure Opening or Pressure Closing Field reversible actuator Teflon packed stuffing box requires no lubrication Open yoke design - accurate travel indication - complete isolation of actuator Construction Materials: Valve Valve Throttling Connection Service Trim Style Available Orifice Sizes 1” Liquid Gas Nominal linear 1/8”, 3/16”, 1/4”, 3/8”, 1/2” Equal percentage 1/4”, 3/8”, 12” 2” Liquid Gas Nominal linear Equal percentage 1/4”, 3/8”, 1/2”, 3/4”, 1” 7/16”, 5/8”, 7/8” Body Stem Plug Cage Actuator Seat Diaphragms High Pressure Motor Valve Steel 303 Stainless Carbide Steel Ductile Iron D2 Steel or Carbide Nitrile/Nylon Non-Freeze High Pressure Dump Steel 303 Stainless Carbide Steel Ductile Iron D2 Steel or Carbide Nitrile/Nylon High Pressure Motor ValveSizes available: 1” NPT, Flanged - Through or Angle Body 2” NPT, Flanged - Through or Angle Body Non-Freeze High Pressure Dump Valve- Carbide Trim HIGH WEAR RESISTANCE - HIGH DIFFERENTIAL PRESSURE SMS Non-Freeze Motor Valve Size available: 1” NPT Inlet & Outlet 2” Vessel Mounting The Non-Freeze Dump Valve places the trim inside the vessel in direct contact with the process liquid, preventing freezing within the valve. Maximum Working Pressure: 4000 psi Valve Available Carbide Connection Orifice Sizes 1” Inlet & Outlet 1/4”, 3/8”, 1/2” 2” Vessel Mounting -20o to 200o F Standard actuator has an effective diaphragm area of 30 square inches. 65 Topworks has an effective area of 65 square inches, which allows a wider adjustable spring range. Maximum Pressure Drop: SMS - 1/4” - 2000 psi 3/8” - 800 psi 1/2” - 450 psi 65 SMS - 1/4”, 3/8”, 1/2” - 4000 psi 65 SMS ‡ Configuration of High Pressure Motor Valve is a trademark of Kimray, Inc. Normal Operating Temperature: Options: Elastomers: HSN, Viton®, Aflas® Trim Material: 316 Stainless Steel internal parts Carbide, 17-4 PH Stainless Trim Configurations: Equal percentage, linear or quick opening Installation: Any position 3-7 Diaphragm Operated Control Valves Balanced Throttle Service - High Pressure Normal Service: Liquids or Gas Piston Balanced High Pressure Motor Valve Features: Piston balanced plug assembly Equal Percentage trim for throttling service Can be used for on / off service Single seat Travel indicator Available in Pressure Opening or Pressure Closing Field reversible actuator Teflon packed stuffing box requires no lubrication Open yoke design - accurate travel indication - complete isolation of actuator Construction Materials: 3-8 Body Stem Plug Piston Cylinder Cage Actuator Seat Diaphragm Steel 303 Stainless Tool Steel or 316 Stainless Tool Steel or 316 Stainless 316 Stainless Steel Ductile Iron Steel or Carbide Nitrile/Nylon High Pressure Motor Valve sizes available: 2” 3” 4” 6” Inner Valve Sizes: 2” 3” 4” 6” HPMV HPMV HPMV HPMV PB PB PB PB - 1 1/2” & 2” Equal Percentage 2” & 3” Equal Percentage 3 ” & 4 3/8” Equal Percentage 6 3/4” Equal Percentage NPT, Flanged ANSI 150, 300, 600, 1500 Flanged ANSI 300, 600 Flanged ANSI 300, 600 Flanged ANSI 300, 600 Maximum Working Pressure: 2” 3” 4” 6” 1500, 4000 psi 1500 psi 1500 psi 1500 psi Normal Operating Temperature: -20oF to 200oF Options: Elastomers: HSN, Viton®, Aflas® Trim Material: 316 Stainless Steel internal parts Installation: Any position Diaphragm Pressure Upstream Pressure Downstream Pressure Diaphragm Operated Control Valves Optional Actuators for High Pressure Valves 65 Topworks -65 Pneumatic Valve Positioner PVP Applications: Applications: Used on 1” & 2” HPMV & 1” SMS Allows a wider spring adjustment range for liquid dumps Allows finer control when used with a pressure controller Used as an operator on 1” and 2” Kimray HPMV’s where valve opening must be set independent of the pressure drop across the valve orifice. Used for linear positioning of Kimray HPMV’s Features: Features: All steel Valve travel inidicator Adjustable Linear stem movement in response to input pressure Maintains stem position through changes in force on stem Insensitive to changes in supply pressure Effective Area: 65 Square inches Stem Travel: 3/4” maximum Actuator Working Pressure: 45 psi maximum Actuator Working Pressure: 45 psi maximum Electropneumatic Valve Positioner Manual Valve Positioner 3-9 EPVP MVP Applications: Applications: Used on 2” HPMV For closing valves manually For opening valves manually For limiting valve stem travel in either direction Features: Sealed bearings Compact design Valve travel inidicator Adjustable Effective Area: 60 Square inches Stem Travel: 3/4” maximum Actuator Working Pressure: 45 psi maximum Used on 2” and 3” Kimray HPMV’s Used for field automation where electrical signals are used to position valve for on / off or precision flow control. Features: Low current consumption Valve travel indicator on open yoke design Easy field repair 1/2” electrical conduit connection designed to Class 1, Division 1 hazardous area specs. Open and Closed valve position contacts CSA Certification Supply Pressure: 30 psi maximum Electrical Control Signal: + 8 to 12 VDC at 200 ma 12 VDC power (optional) Diaphragm Operated Control Valves Three Way Control Valves Three Way Motor Valve - Low Pressure 3W Three Way Motor Valve - High Pressure Normal Service: Liquids Normal Service: Liquids Features: Features: Soft seats for tight shut-off Balanced design 10 psi minimum diaphragm pressure Available in lower port normally closed or open Special stem seal requires no lubrication Valve position indicator Removable seats Soft seats for tight shut-off 30 psi max. diaph. pressure Available in lower port normally closed or open Special stem seal requires no lubrication Valve position indicator Removable seats 3W Max. Operating Pressure: 3000 psi Connection: 1” NPT Construction Materials: 3-10 Steel Stem 303 Stainless Plug Steel Cage Steel Actuator Ductile Iron Seat Polyurethane / Steel Diaphragm Nitrile/Nylon Normal Operating Temperature: Maximum Operating Pressure Ductile Iron Ductile Iron Steel Diaph. Balanced Piston Balanced Piston Balanced NPT Body 2” 3” 125 400 400 400 Flanged 2” 3” 125 250 250 285 Grooved 2” 3” 125 400 400 400 -20o to 200o F Options: Adjustable - 65 Topworks Installation: Any position Three Way Motor Valve - High Pressure Splitter 3W Normal Service: Liquid or Gas Features: Construction Materials: Designed for Splitting or Mixing 30 psi max. diaph. pressure Available in lower port normally closed or open Special stem seal requires no lubrication Valve position indicator Body Stem Cage Disc Seat Diaph. Balanced Piston Balanced Ductile Iron 303 Stainless Ductile Iron Ductile Iron Steel 303 Stainless Ductile Iron Ductile Iron Nitrile Polyurethane Polyurethane 3000 psi Diaphragms Nitrile/Nylon Nitrile/Nylon Connection: Max. Operating Pressure: 2” NPT or Weld Sizes available: 2” NPT, Grooved, Flanged 3” NPT, Grooved, Flanged Ductile or Steel Ductile Normal Operating Temperature: -20o to 200o F Options: Elastomers: HSN, Viton , Aflas Trim Material: 316 Stainless Steel internal parts ® Installation: Any position ® Construction Materials: Body Steel Stem 303 Stainless Plug 303 StainlessSteel Cage 303 Stainless Actuator Ductile Iron Diaphragm Nitrile/Nylon Installation: Any position Normal Operating Temperature: -20o to 200o F Mechanical Control Valves Float / Lever Operated Normal Service: Liquids ‡® Features: Quick opening trim Balanced single seat Teflon packed rotary stuffing box Soft seat for bubble tight shut-off Available in Angle or Through Body Construction Materials: Diaphragm Balanced Mechanical Valves ‡® Balancing Diaphragm Allows the valve to shut against full rated upstream pressure.. Body Stem Plug Cage Disc Seat Cast Iron Ductile Iron 303 Stainless 303 Stainless Ductile Iron Ductile Iron Ductile Iron Ductile Iron Ductile Iron Ductile Iron Nitrile Polyurethane Diaphragm Nitrile/Nylon Nitrile/Nylon Stuffing Box Brass Brass Packing Nitrile Nitrile Steel 303 Stainless Steel Ductile Iron Ductile Iron Polyurethane Nitrile/Nylon Brass Nitrile 3-11 Sizes available: 2” 3” 4” 6” Maximum Operating Pressure NPT Flanged 2” 3-4” 2” 3-4” 6” Cast Iron 125 125 125 125 Ductile Iron 250 125 250 125 125 Steel 250 125 125 NPT, Flanged NPT, Flanged Flanged Flanged Normal Operating Temperature: -20o to 200o F Options: Elastomers: HSN, Viton®, Aflas® Trim Material: 316 Stainless Steel internal parts Installation: Any position Piston Balanced Mechanical Valves ‡® Balancing Piston Same balancing action as with the Diaphragm Balanced Valve. Used for higher pressures. Maximum Operating Pressure NPT Flanged 2” 3-4” 2” 3-4” Cast Iron 125 125 Ductile Iron 500 250 250 250 Steel 285 285 ‡Configuration of Mechanical Oil Valve is a trademark of Kimray, Inc. SPEAKING OF SIMPLICITY: Our mechanical control valve may not look that special, but it sure has been copied a lot! A simple thing that works well-it’s no mystery that it has been imitated so much. Mechanical Liquid Level Control Trunnion Assemblies Normal Service: Liquids Features: Teflon packed rotary stuffing box 303 Stainless steel shaft Stainless steel adjustable linkage 3/4” float arm hub TANK SHUT OFF INSTALLATION 8” Hammer Union Trunnion Assembly HUTA 3-12 Style Material Max. W.P. One Piece Single End Shaft Two Piece Single End Shaft Two Piece Double End Shaft Ductile Iron Ductile Iron Ductile Iron 250 psi 250 psi 500 psi Float Cover & Trunnion Assembly TO-D MECHANICAL DUMP INSTALLATION Material: Ductile Iron Opening Size: 6”, 8”, 10” Working Pressure: 250 psi Trunnion Assembly Style ‡Configuration of Mechanical Oil Valve is a trademark of Kimray, Inc. Material Max. W.P. TOB Bolt-On Single End Shaft Bolt-On Double End Shaft Weld-On Double End Shaft Ductile Iron 250 psi Ductile Iron 500 psi Steel 500 psi Mechanical Control Valves Weight Operated Normal Service: As oil or water valve for treaters, water knockouts and gunbarrels. For pressure, atmospheric, or vacuum operation. For discharging salt water to disposal systems. ‡® Features: Treater Valve WA Balancing Diaphragm Allows the valve to shut against full rated upstream pressure or vacuum. ‡® 2” 2” 3” 4” 6” Construction Materials: Body Shaft Plug Cage Disc Seat Diaphragms StuffingBox Packing Maximum Operating Pressure NPT Flanged Soft seat for tight shut-off Balanced against upstream pressure Balanced against downstream pressure or vacuum Standard weight and lever holds approx. 4’ head Weights may be added to increase liquid head Can be manually opened and closed Sample tap on inlet connnection Rotary stuffing box with Teflon packing All interior parts can be removed without taking valve out of line Prevents air from entering salt water disposal system piping Cast Iron Ductile Iron Steel 125 60 60 60 60 125 125 125 125 Cast Iron 303 Stainless Gray Iron Gray Iron Ductile Iron Nitrile Nitrile/Nylon Brass Nitrile Ductile Iron 303 Stainless Gray Iron Gray Iron Ductile Iron Nitrile Nitrile/Nylon Brass Nitrile Steel 303 Stainless Steel Gray Iron Gray Iron Nitrile Nitrile/Nylon Brass Nitrile Sizes available: 125 2” 3” 4” 6” NPT, Flanged Flanged Flanged Flanged Normal Operating Temperature: INSTALLATION -20o to 200o F Options: Elastomers: HSN, Viton®, Aflas® Trim Material: 316 Stainless Steel internal parts Installation: Horizontal TREATER VALVE that’s what we call it. ‡Configuration of Water Valve is a trademark of Kimray, Inc. One of Kimray’s first products,the Treater Valve is still widely used today. We think that’s because our engineers keep saying, “Keep it SIMPLE Build it RUGGED Make it DEPENDABLE.” 3-13 Electric & Manually Operated Control Valves 3-14 Features: Service: Modulating or On / Off Fail Closed with loss of power AC or DC Electric Acuator Multiple Input options, standard NEMA Class enclosures Permanently lubricated gear train Acuator Temp: -40° to 150°F Power Requirement Options: 115VAC 230VAC 24VDC Input: These connection types are included: 4-20 ma, 1-5V, 0-5V, 0-10V Options: Elastomers: HSN, Viton®, Aflas® Trim Material: 316 Stainless Steel internal parts Enclosure Options: NEMA 4 Weather Tight NEMA 7 Explosion Proof, CSA Applications: Used to meter or control flow of liquids and/or gases on meter runs, flow lines, or may be used as a choke under low pressure drop conditions where freezing is not a problem. Features: Electronically Actuated Valve EA Valve Connection Max. W.P. Orifice Size Material 4” ANSI 150FF 125 psi 3” Ductile 6” ANSI 150FF 125 psi 7/ ” 8 Ductile 4 Metering Valve MV Equal Percentage trim Position scale graduated in 64ths orifice increments Teflon packed stuffing box requires no lubrication O-Ring sealed seat Easily adjusted Construction Materials: Body Stem Plug Cage Manual Actuator Seat Steel 303 Stainless Steel, Carbide or 316 Stainless Steel Aluminum / Brass / Steel Steel or 316 Stainless Metering ValveSizes available: 1” NPT, Flanged 2” NPT, Flanged 3” Flanged Maximum Working Pressure: 4000 psi Normal Operating Temperature: Valve Connection Trim Style 1” Linear Equal Percentage Available Orifice Sizes 1/4”, 1/2” 1/4”, 1/2” Equal Percentage 7/16”, 5/8”, 7/8” Piston Balanced Equal Percentage 2” Piston Balanced Equal Percentage 3” -20o to 200o F Options: Elastomers: HSN, Viton®, Aflas® Trim Material: 316 Stainless Steel internal parts or 17-4 PH Stainless 2” Any position 3” Installation: 4-1 ‡ Configuration of Glycol Pump is a trademark of Kimray, Inc. Product Selection Guide Glycol Pumps Glycol Pumps Dehydrator Dry gas out Dry Glycol Reboiler Absorber (Contactor) Wet gas in Wet Glycol Pump Dry Glycol Wet Glycol Heat Exchanger Surge Tank 4-2 Natural Gas Glycol Pump Wet natural gas enters the bottom of the absorber. It flows upward through a packed bed or through a series of bubble cap or valve trays filled with glycol where thorough contact is made. The gas gives up water vapor to the glycol as it passes upward and leaves the absorber as dry gas ready to enter the sales line. The Glycol Pump takes glycol at absorber pressure, moves it into the reboiler at atmospheric pressure, and then returns it to pressure adequate to drive the glycol back into the abosrber. All this is accomplished by utilizing some of the gas at absorber pressure to drive the system without an additional source of outside energy. Glycol The Glycol Pump operates in various demanding conditions: high temperature, high pressure, varied chemical contaminates, and potential of a wide range of abrasive materials. The dry concentrated glycol is continuously pumped to the top tray of the absorber. As the glycol moves downward from tray to tray it absorbs the water vapor from the rising gas stream. The wet glycol is then removed at the bottom of the absorber and pumped through a large preheating coil in the surge tank. It then enters the still column at the top of the reboiler where the water vapor is stripped away as steam. The regenerated glycol spills down into the surge tank and is pumped to the top of the absorber to start another cycle. Nearly 50 years of demanding service have proven the ruggedness and dependability of the unique and robust design. Glycol Pumps ‡® Function: Circulates glycol in a dehydration system. Circulates amine in a desulphurizer system. Utilizes the energy of gas and glycol at absorber pressure as its source of power. Features: High Pressure Model Number 315 PV 1715 PV 4015 PV 9015 PV 21015 PV 45015 PV Capacity Gallons / Hour Minimum Maximum 3 13 8 40 12 40 27 90 66 210 166 450 PV Working Pressure Minimum Maximum 100 1500 300 1500 300 1500 300 1500 400 1500 400 1500 Low Pressure (Small Cylinder) Model Number 2015 SC 5015 SC 10015 SC 20015 SC Capacity Gallons / Hour Minimum Maximum 8 20 12 50 22 100 60 200 SC Working Pressure Minimum Maximum 100 500 100 500 100 500 100 500 No auxiliary power required Eliminates need for level control and dump valve at absorber Low gas consumption Completely sealed system prevents glycol loss Only two moving assemblies Hydraulic “cushioned” check valves with removable seats of hardened stainless steel Circulation Rates: SC Series 8 - 200 gph PV Series 3 - 450 gph Working Pressure: 1500 psig Options: Elastomers: HSN, Viton®, Aflas® Metal Materials: 316 Stainless Steel, 17-4 PH Stainless Steel Features: Sock type element In line filter removal 1/4” NPT Bleed Valve connection Hammer union cap Solid mount 3/4” NPT inlet and outlet connections Temperature Range: -20 to 650oF Working Pressure: 1500 psig Recommended Pumps: 315PV 4015PV 9015PV 2015SC 5015SC Glycol Filter Canister Used to filter particles of rust, sludge and debris from the glycol lines before the glycol reaches the pumping system. This allows the glycol pump to operate more freely and reduces pump wear. The filter itself is disposable and can easily be replaced. ‡ Configuration of Glycol Pump is a trademark of Kimray, Inc. 4-3 Dehydration Equipment Liquid Level Control Universal Level Control ULC GEN 2 Liquid Level Controller Features: Direct acting Intermittent bleed pilot Simple installation Easy to use No adjustment required .65 specific gravity or higher Bodies Available: 4-4 1” NPT Brass, Steel, or Stainless Steel 2” NPT Steel or Stainless Steel Supply Pressure: 0-35 psig maximum Vessel Operating Pressure: 50 to 4000 psig maximum Maximum W.P.: 1500 psig Supply Pressure: 30 psig max. Temperature Range: -20 to 200oF Optional elastomers provide higher maximum temperature Maximum Temperature: 200oF Options: Float Travel:3/4” maximum Low density, high temperature float Vertical float adapter Features: 2 inch NPT Vessel Connection Low Friction Waggle Arm: no rotating stuffing box and related friction/stiction Vibration resistant: utilizes inherent negative feed back for increased stability Adjustable Sensitivity: adjustable from 2.5 psig to 6 psig output/inch of level change in vessel Differential Specific Gravity: 1.0 to .33 Adjustable level control: one simple adjustment Direct or indirect output: simple single adjustment to change from direct to inidirect output Single spring: one spring for all liquid densities and interface control Lever switches between Throttle or Snap Control Other Kimray dehydration equipment: Liquid Level Controls Dump Valves Thermostats Burner Valves Pressure Regulators Large volume pilots: large three-way valve reduces sensitivity to fluids and trash in supply line, provides high volume output Built-in supply filter Durable: designed to operate in severe environments Vertical or Horizontal Displacer: field configurable Vented Case: 1/4” NPT tapped vent is easy to connect and pipe exhaust away if needed Low initial cost THERE’S A LOT MORE TO GAS DEHYDRATION THAN THE KIMRAY GLYCOL PUMP! Dehydration Equipment Dump Valves and Burner Valves High Pressure Motor Valve ‡® Angle or Thru valve body Carbide trim Ideal for high pressure differential On / Off service Valve Connection 1” 2” Available Orifice Sizes 1/8”, 3/16”, 1/4”, 3/8” 1/4”, 3/8”, 1/2”, 3/4”, 1” ‡ Configuration of High Pressure Motor Valve is a trademark of Kimray, Inc. Non-Freeze High Pressure Dump Valve The Non-Freeze Dump Valve places the trim inside the vessel in direct contact with the process liquid, preventing freezing within the valve. SMS Valve Available Carbide Connection Orifice Sizes 1/4”, 3/8”, 1/2” 1” Inlet & Outlet 2” Vessel Mounting Standard actuator has an effective diaphragm area of 30 square inches. 65 Topworks has an effective area of 65 square inches, which allows a wider adjustable spring range. Maximum Pressure Drop: 65 SMS Construction Materials: Valve Body Stem Plug Cage Actuator Seat Diaphragms High Pressure Motor Valve Steel 303 Stainless 303 Stainless Steel Ductile Iron Steel Nitrile/Nylon Non-Freeze High Pressure Dump Steel 303 Stainless Carbide Steel Ductile Iron D2 Steel or Carbide Nitrile/Nylon High Pressure Motor ValveSizes available: 1” NPT, Flanged - Angle or Through Body 2” NPT, Flanged - Angle or Through Body Non-Freeze Motor Valve Size available: 1” NPT Inlet & Outlet 2” Vessel Mounting Maximum Working Pressure: 4000 psi Temperature Range: -20o to 200o F 4-5 Elastomers: HSN, Viton®, Aflas® Trim Material: Stainless Steel, Carbide 65 SMS - 1/4”, 3/8”, 1/2” - 4000 psi SMT DAB Pressure opening Burner Valve used where a reduced inner valve is desired and manifold pressures do not exceed 25 psig. Adjustable Pressure Opening Quick opening trim Travel indicator Available in Pressure Opening or Pressure Closing Field reversible actuator Teflon packed stuffing box requires no lubrication Open yoke design - accurate travel indication - complete isolation of actuator Options: SMS - 1/4” - 2000 psi 3/8” - 800 psi 1/2” - 450 psi Spring Closing Pressure Opening Normal Service: Liquids Features: SMT ADA Normal Service: Liquids Features: Equal Percentage trim Soft seat for bubble tight shut-off Special stem seal requires no lubrication Construction Materials: Body Cast Iron Ductile Iron Steel Design Pressure Scrd. 175 psi Flgd. 175 psi Scrd. 300 psi Flgd. 250 psi Flgd. 285 psi Stem 303 Stainless 303 Stainless 303 Stainless Plug Ductile Iron Ductile Iron Steel Seat Nitrile Polyurethane Polyurethane Nitrile/Nylon Nitrile/Nylon Diaphragms Nitrile/Nylon Pressure opening Burner Valve for throttling or snap action service and where manifold pressures do not exceed 40 psig. Sizes available: 1” NPT 2” NPT, Flanged Temperature Range: -20o to 200o F Options: Elastomers: HSN, Viton®, Aflas® Trim Material: 316 Stainless Steel internal parts Orifice Size: LIne size or reduced THERE’S A LOT MORE TO GAS DEHYDRATION THAN THE KIMRAY GLYCOL PUMP! Dehydration Equipment Thermostats & Supply Gas Regulator Thermostat Features: Single adjustment High accuracy Intermittent-bleed construction Bi-metalic sensing element Indirect Throttle Thermostat T 12 Indirect control of burner valves, mixing valves, air shutters Supply Pressure: 5 to 30 psig Working Pressure (sensing element): 500 psig without Separable Socket 4000 psig with Separtable Socket 7000 psig with Special Separable Socket Separable socket is an extra price item and is ordered separately. Indirect High Temperature Shut-Down For temperature controlled system shutdown until manually reset Shuts off when system temperature exceeds setpoint Temperature Range: T 12, T 18 HT 12, HT 18 Pilot Guard -30o to 400o F -34o to 204o C -30o to 750o F -34o to 399o C -30o to 2100o F -34o to 1149o C Options: Elastomers: HSN, Viton®, Aflas® Metal Material: 316 Stainless Steel internal exposed parts 4-6 T 12M Pilot Guard HT12 PG Indirect action for system shut-down when pilot flame goes out. Also used in direct mode for high stack temperture shutdown Indirect Acting Thermostats: Output decreases with temperature rise. Supply Gas Regulator Features: Easily adjusted Internally relieving Available in Aluminum and 316 Stainless Steel Connections: Inlet and Outlet - 1/4” NPT Supply Gas Regulator SGR Maintains constant downstream pressure. Provides a supply of constant reduced pressure for pneumatic instruments and pilot operated controllers. Operating Temperature: 0o to 200oF (-18oC to 93oC) Maximum Inlet Pressure: 4000 psi Outlet Pressure: 0 to 125 psi Construction Materials: Body: Aluminum or 316 Stainless Steel Diaphragm: Polyurethane Seat: Nylon THERE’S A LOT MORE TO GAS DEHYDRATION THAN THE KIMRAY GLYCOL PUMP! 5-1 Product Selection Guide Temperature Controllers Temperature Controllers Selection Guide Contents Temperature Controllers Selection Guide Temperature Controllers Selection Guide...............2 Throttling Thermostats............................................3 Throttling Thermostats Provide a proportional pneumatic output for control of burner valves, mixing valves or air shutters. Snap Acting Thermostats ......................................4 Snap Acting Thermostats Provide an on / off pneumatic output for control of burner valves, mixing valves or air shutters. Shut-Downs............................................................5 Shut-Downs Provide an on / off pneumatic output for shutting down of burner valves or mixing valves. Burner Valves.........................................................6 Burner Valves Modulate burner flame or shut-in burner systems. Separable Sockets & Thermowells ........................6 Separable Sockets & Thermowells Protect Thermostats or Thermometers. Allows Thermostat or Thermometer removal without losing vessel pressure. 5-2 PROVEN DESIGN With 57 years of building experience, many of our original designs are still current technology, tried and tested in literally thousands of installations. Temperature Controllers Throttling Thermostats Indirect Throttle T 12 Features: Single adjustment High accuracy Intermittent-bleed construction Bi-metalic sensing element Supply Pressure: 5 to 30 psig Working Pressure (sensing element): Indirect control of burner valves, mixing valves, air shutters Indirect Throttle High Capacity T 12T 500 psig without Separable Socket 4000 psig with Separtable Socket 7000 psig with Special Separable Socket Separable socket is an extra price item and is ordered separately. Temperature Range: T 12, T 18 HT 12, HT 18 -30o to 400o F -34o to 204o C -30o to 750o F -34o to 399o C Options: Elastomers: HSN, Viton®, Aflas® Metal Material: 316 Stainless Steel internal exposed parts Indirect control of burner valves, mixing valves, air shutters where quick response or high volume of pneumatic output is required. Indirect Throttle with Burner Valve 1TC 12 Indirect Acting Thermostats: Output decreases with temperature rise. Direct Acting Thermostats: Output increases with temperature rise. NO “DEADBAND” Temperature controller includes T 12 Thermostat, Filter Pop Valve, and 1” Burner Valve. Direct Throttle T 12TDA The sensing element in the Kimray Thermostat is a bi-metalic probe. The outer tube is 304 stainless steel, and the inner rod is low expansion nickel. The expansion rates due to heat in both the metals are very consistent which provides smooth, proportional output -- throttling action. When the thermostat is installed with its probe completely surrounded by the liquid or gas it is monitoring, there is virtually no deadband. Other types of thermostats providing such control cost considerably more, and lack the simplicity. In describing the Kimray Thermostat folks have said, Direct control of burner valves, mixing valves, air shutters “IT’S LIKE A CADILLAC THERMOSTAT AT A CHEVY PRICE!” 5-3 Temperature Controllers Snap Acting (On / Off) Thermostats Features: Direct Snap T 12DA Single adjustment High accuracy Intermittent-bleed construction Bi-metalic sensing element Supply Pressure: 5 to 30 psig Working Pressure (sensing element): 500 psig without Separable Socket 4000 psig with Separtable Socket 7000 psig with Special Separable Socket Separable socket is an extra price item and is ordered separately. Direct on/off control of burner valves, mixing valves, air shutters Temperature Range: T 12, T 18 HT 12, HT 18 -30o to 400o F -34o to 204o C -30o to 750o F Direct Snap High Capacity T 12S -34o to 399o C Options: Elastomers: HSN, Viton®, Aflas® Metal Material: 316 Stainless Steel internal exposed parts Indirect Acting Thermostats: Output decreases with temperature rise. Direct Acting Thermostats: Output increases with temperature rise. 5-4 Direct on/of control of burner valves, mixing valves, air shutters where high volume of pneumatic output is required. Indirect Snap T12 DAS “WHAT’S A SEPERABLE SOCKET?” Some call it a Thermowell. We call the well for a thermometer a Thermowell. The Separable Socket is a protective well designed for the Kimray Thermostat. It protects the Thermostat probe from corrosion or physical forces which could bend it. It also increases the maximum working pressure of the Thermostat. Indirect on/off control of burner valves, mixing valves, air shutters Temperature Controllers Shut - Downs Indirect High Temperature Shut-Down T 12M Features: Single adjustment High accuracy Intermittent-bleed construction Bi-metalic sensing element Supply Pressure: 5 to 30 psig Working Pressure (sensing element): 500 psig without Separable Socket 4000 psig with Separtable Socket 7000 psig with Special Separable Socket Separable socket is an extra price item and is ordered separately. Temperature Range: T 12, T 18 For temperature controlled system shutdown until manually reset. Shuts off when system temperature exceeds setpoint HT 12, HT 18 -30o to 400o F -34o to 204o C -30o to 750o F -34o to 399o C Direct Low Temperature Shut-Down T 12DAM Options: Elastomers: HSN, Viton®, Aflas® Metal Material: 316 Stainless Steel internal exposed parts Indirect Acting Thermostats: Output decreases with temperature rise. Direct Acting Thermostats: Output increases with temperature rise. 5-5 For temperature controlled system shutdown until manually reset. Shuts off when system temperature drops below setpoint Pilot Guard HT12 PG “TURN IT OFF, QUICK!” Sometimes it’s too hotSometimes it’s too coolSometimes the fire just goes out. Whatever the reason, if the temperature gets out of control, you need to shut everything off right away! These shut-downs are just what you need, when you need to stop and start over. Indirect action for system shut-down when pilot flame goes out. Also used in direct mode for high stack temperture shutdown Temperature Controllers Burner Valves, Separable Sockets &Thermowells Features: Spring Closing Pressure Opening Equal Percentage trim Single seat Soft seat for bubble tight shut-off Pressure Opening / Fail Closing Special stem seal requires no lubrication SMT DAB Pressure opening Burner Valve where a reduced inner valve is desired and manifold pressures do not exceed 25 psig. Construction Materials: Body Cast Iron Ductile Iron Steel Design Pressure Scrd. 175 psi Flgd. 175 psi Scrd. 300 psi Flgd. 250 psi Flgd. 285 psi Stem 303 Stainless 303 Stainless 303 Stainless Plug Ductile Iron Ductile Iron Steel Seat Nitrile Polyurethane Polyurethane Nitrile/Nylon Nitrile/Nylon Diaphragms Nitrile/Nylon Adjustable Pressure Opening SMT ADA Pressure opening Burner Valve for throttling or snap action service and where manifold pressures do not exceed 40 psig. Sizes available: DAB & MT-T: 1” NPT 2” NPT, Flanged 3” NPT, Flanged 4” Flanged 6” Flanged ADA: 1” NPT 2” NPT, Flanged Fail Closed Pressure Opening Pressure opening Burner Valve for throttle action service, or shut in against pressures up to 300 psig. Uses upstream pressure to close valve when no open signal is present. Normal Operating Temperature: -20o to 200o F Options: Elastomers: HSN, Viton®, Aflas® Trim Material: 316 Stainless Steel internal parts Orifice Size: LIne size or reduced 5-6 Features: Increases working pressure of Thermostat Sensing Element. Allows Thermostat removal without losing vessel pressure. Filled with high temperature grease. Separable Sockets Separable Socket Materials: Steel & 316 Stainless Working Pressure: 1000, 4000, & 7000 psig Connections: External Thread: 3/4” and 1” NPT Internal Thread: 1/2” NPT Allows thermometer removal for maintanence without losing vessel pressure. Thermowell Materials: 304 SS & 316 SS Working Pressure: 1000 to 4000 psig W.P. Connections: External Thread: 1/2” and 3/4” NPT Internal Thread: 1/4” and 1/2” NPT SMT-T Thermometer Wells 6-1 Product Selection Guide Relays & Pilots Relays & Pilots Selection Guide Contents Relays & Pilots Selection Guide .............................2 Relays & Pilots Selection Guide Relays Relays Snap & Throttle .......................................................3 Manual Reset..........................................................4 Manual & ReverseThrottle ......................................4 Mechanical, Bistable, High Pressurre, Priority........5 Pressure Pilots Low Pressure ..........................................................6 High Pressure .........................................................8 Differential Pressure ...............................................9 Enhance a pneumatic or mechanical input signal Provide Reversed Output Multiplied Output Volume Boosted Output On / Off Snap Output Pilots Provide output signal for condition monitor Provide output signal to a remote valve for Back pressure control Pressure reduction Differential pressure control Vacuum control Accessories Supply Gas Regulator, Sense Line Protecto r.......11 Filter, Drip Pots, Air Motor.....................................12 Companion Flange Sets, Check Valves ...............13 The Tinker Toy approach to assembling control devices: 6-2 We have always felt that if you understand the way each of our Pilots, Relays, and Valves works, you can assemble a gizmo that will do about anything you need done in controlling temperature, liquid level, pressure or flow. And if you don’t quite understand call us, and TOGETHER WE’LL FIGURE IT OUT! Relays Indirect Snap Relay 3PS Throttle Relay 3 PG Function: Reverses and converts a varying pneumatic signal to an on / off signal. Function: Multiplies and volume boosts a pneumatic signal to a large motor valve or similar equipment. Features: Features: Pneumatic snap action Reverse action Supply Pressure: 30 psi maximum Pneumatic throttle action Direct action Field reversible Input signal: 0 - 10 psi minimum Supply Pressure: 30 psig maximum Input signal: 0 to 30 psig 0 - 30 psi maximum Output signal: 0 psig or supply pressure Output signal: 4 times input signal (up to supply pressure) Direct Snap Relay 3PS DA Throttle Relay 3 PGA Function: Volume boosts a pneumatic signal to a large motor valve or similar equipment. Function: Converts a varying pneumatic signal to an Features: on / off signal. Pneumatic throttle action Direct action Features: Pneumatic snap action Adjustable Supply Pressure: 30 psi maximum Input signal: 0 - 15 psi minimum 0 - 30 psi maximum Output signal: 0 psig or supply pressure Supply Pressure: 30 psi maximum Input signal: 2 - 30 psig Output signal: 2 - 30 psig 6-3 Relays Manual Reset Relay 3PGM Function: Shuts off supply pressure when input is lost, and requires manual reset before pressure is restored. Features: Features: Supply Pressure: 30 psig maximum Supply Pressure: 300 psig maximum Output signal: 0 psig or supply pressure Output signal: 0 psig or supply pressure 3PGRA Function: Reverses and multiplies a varying pneumtatic signal. Features: Reverse acting Throttle action Adjustable variable pressure Direct acting Mounting bolts for bracket mounting Controls up to 300 psig with minimal manual effort Pressurestat Reverse acting Throttle action Adjustable steam pressure Output signal: 0 to 20 psig Variable Pressure (Input signal): 0 to 12 psig 30 psig max. Pressure Ratio: (Out put to input) 1.5 : 1 3 PGP Function: Direct firing of small steam generators by controlling flow of gas through the pilot to the burner. Approximate capacity of pilot is 360 SCFH with 15 psig supply pressure. Pressure control of larger steam generators by regulating flow of gas through a motor valve. Features: Supply Pressure: 5 to 30 psig 3 PGMR Function: Manually sends a control signal to open or close a valve using a palm button. Supply is blocked and control signal bled to vent when released. Manual reset Provides visual indication when limit is exceeded Rapid venting action Direct acting Throttle-Reverse Relay 6-4 Manual Relay Supply Pressure: 30 psi maximum Output Pressure: 0 - 30 psig Steam Pressure: 15 psig max. Steam Pressure: 250o F max. Relays Bistable Relay 3PGB Function: Two temporary pressure signals are used, one to turn “ON” the relay and one to turn “OFF” the relay. Relay remains ON or OFF when control signal is removed. until the opposite signal is applied. Features: Bistable operation Temporary signal will turn “ON” or “OFF” Semi-snap action Mechanical Relay 3 PM Features: Direct float operated Snap or throttle action Field reversible Controls motor valve requiring up to 30 psi diaphragm pressure Supply Pressure: 20 to 30 psig Output signal: 0 psig or supply pressure ON / OFF Signal: 20 to 30 psig High Pressure Relay 30 PGR Priority Relay Function: A 0 to 300 psig signal is switched using a 20 to 30 psig signal Function: Allows a pneumatic signal to override an existing signal. Features: Max. Inlet Pressure Port 1: 1 - 40 psig Up to 300 psig supply 20 to 30 psig ON / OFF signal Direct acting Max. Inlet Pressure Port 2: 2 - 40 psig Supply Pressure: 0 to 300 psig Output signal: 0 psig or Supply Pressure Variable Pressure (Input signal): 20 to 30 psig 4 POR Pressure required at Port 2 to override the pressure at Port 1: 20 psig or 70% of the pressure at Port 1 (whichever is greater) 6-5 Pressure Pilots Low Pressure and Vacuum Features: Single adjustment Filtered gas supply High accuracy Intermittent-bleed construction Remote installation Supply Pressure: 20 to 30 psig to operate high pressure motor valves. May require higher supply pressure when installed with some low pressure motor valves. Call Kimray if in doubt. Optional Pressure Spring Ranges: .5 oz. to 2.5 psig 1 oz. to 5 psig 1 psig to 20 psig Ounces Pressure Reducing to Atmosphere Optional Vacuum Spring Ranges: OPRA Pressure Range: .5 oz. to 20 psig Produces a proportional pneumatic output signal when the monitored pressure falls below the set pressure. The pilot may be remotely installed to operate a motor valve and function as a pressure regulator. .065 to 5 inches Hg .13 to 10 inches Hg 2 to 30 inches Hg Normal Operating Temperature: -20o to 200o F Ounces Pressure Reducing - Direct Options: Elastomers: HSN, Viton®, Aflas® Metal Material: 316 Stainless Steel Tubing, Fittings, and internal exposed parts OPRA DA Pressure Range: .5 oz. to 20 psig Produces a proportional pneumatic output signal when the monitored pressure rises above the set pressure. The pilot may be remotely installed to operate a motor valve and function as a pressure regulator. Ounces Pressure Reducing Vacuum OPRV Pressure Range: 1” TO 30” Hg Vacuum Produces a proportional pneumatic output signal when the monitored vacuum becomes weaker than the set point. The pilot may be remotely installed to operate a motor valve and function as a pressure regulator. 6-6 PILOT? The PILOT of a ship or an airplane watches where he is going and makes slight corrections when he sees that he is not on course. A ‘PRESSURE PILOT’ is like that. It watches the pressure and makes slight corrections if the pressure starts to get ‘OFF COURSE.’ Ounces Pressure Reducing Vacuum Direct OPRV DA Pressure Range: 1” TO 30” Hg Vacuum Produces a proportional pneumatic output signal when the monitored vacuum becomes stronger than the set point. The pilot may be remotely installed to operate a motor valve and function as a pressure regulator. Pressure Pilots 300 psig Maximum Controlled Pressure Features: Single adjustment Filtered gas supply High accuracy Intermittent-bleed construction Remote installation Supply Pressure: 20 to 30 psig to operate high pressure motor valves. May require higher supply pressure when installed with some low pressure motor valves. Call Kimray if in doubt. Optional Pressure Spring Ranges: 5 to 125 psig up to 300 psig Normal Operating Temperature: -20o to 200o F Options: Pressure Reducing PG PR Pressure Range: 5 to 300 psig Elastomers: HSN, Viton®, Aflas® Metal Material: 316 Stainless Steel Tubing, Fittings, and internal exposed parts Produces a proportional pneumatic output signal when the monitored pressure falls below the set pressure. The pilot may be remotely installed to operate a motor valve and function as a pressure regulator. High Pressure Pressure Reducing HPG PR Pressure Range: 5 to 300 psig Produces a proportional pneumatic output signal when the monitored pressure falls below the set pressure. The pilot may be remotely installed to operate a motor valve and function as a pressure regulator. The pneumatic source is isolated from the monitored pressure by a vent chamber which allows the monitored pressure to vent away if it reaches a high enough pressure to cause diaphragm failure. Pressure Reducing - Direct Acting PG PRDA Pressure Range: 5 to 300 psig Produces a proportional pneumatic output signal when the monitored pressure rises above the set pressure. The pilot may be remotely installed to operate a motor valve and function as a pressure regulator. Direct or Indirect? A DIRECT acting pilot sends an increasing output pressure when it senses an increasing controlled pressure. An INDIRECT acting pilot sends a decreasing output pressure when it senses an increasing controlled pressure. The PG PR and HPG PR Pilots are INDIRECT acting pilots. 6-7 Pressure Pilots 500, 750, 1500 psig Max. Controlled Pressure Features: Single adjustment High accuracy Intermittent-bleed construction Remote installation Supply Pressure: 20 to 30 psig to operate high pressure motor valves. Normal Operating Temperature: -20o to 200o F Options: Elastomers: HSN, Viton®, Aflas® Metal Material: 316 Stainless Steel internal exposed parts 50 PG 75 / 150 PG Pressure Reducing 50 PG Pressure Range: 50 to 500 psig Produces a proportional pneumatic output signal when the monitored pressure falls below the set pressure. The pilot may be remotely installed to operate a motor valve and function as a pressure regulator. DOING THINGS WELL! 6-8 Our sales and technical people often recommend some of our competitor’s products! Why? We realize that we can’t do everything, so we try to limit our efforts to what we do well. Reversible High Pressure Reducing 75 / 150 PG Pressure Range: 50 to 1500 psig Produces a proportional pneumatic output signal when the monitored pressure deviates from the set pressure. The pilot may be remotely installed to operate a motor valve and function as a pressure regulator. Pilot is field convertible between Direct and Indirect acting. Bellows options: 50 to 750 psig 125 to 1500 psig Pressure Differential Controls 300 psig Maximum Working Pressure Features: Single adjustment Filtered gas supply High accuracy Intermittent-bleed construction Remote installation Supply Pressure: 20 to 30 psig to operate high pressure motor valves. May require higher supply pressure when installed with some low pressure motor valves. Call Kimray if in doubt. Optional Pressure Spring Ranges: 5 to 125 psig up to 300 psig Normal Operating Temperature: -20o to 200o F Options: Pressure Differential PG PD Pressure Range: 5 to 300 psig Elastomers: HSN, Viton®, Aflas® Metal Material: 316 Stainless Steel Tubing, Fittings, and internal exposed parts Produces a proportional pneumatic output signal when the monitored differential pressure falls below the set pressure. The pilot may be remotely installed to operate a motor valve and function as a pressure differential regulator. Uses the upstream pressure for supply pressure. Liquid Differential PG LDP Pressure Range: 5 to 300 psig Produces a proportional pneumatic output signal when the monitored differential pressure falls below the set pressure. The pilot may be remotely installed to operate a motor valve and function as a pressure differential regulator. Uses an outside source of instrument gas up to 300 psig. Differential Pressure - Direct Acting AVAILABILITY One of Kimray's greatest strengths is our inventory and our ability to build to order and ship promptly. PG PDDA Pressure Range: 5 to 300 psig Produces a proportional pneumatic output signal when the monitored differential pressure rises above the set pressure. The pilot may be remotely installed to operate a motor valve and function as a pressure regulator. Uses an outside source of instrument gas up to 30 psig. 6-9 Pressure Differential Regulator Up to 4000 psig Static Pressure Pressure Differential Controller A Pressure Differential Regulator can be assembled using the following Kimray devices: High Pressure Motor Valve 1”-6” Pressure Differential Controller: 100 PDC for 1000 psi max. static pressure 200 PDC for 2000 psi max. static pressure 400 PDC for 4000 psi max. static pressure Instrument Gas Regulator Drip Pot Steel Tubing & Fittings PDC Controlled Pressure Differential Range: 1 to 260 inches H2O Maintains a constant pressure differential across another device within the same flowing system. The “PDC” Series Pressure Differential Controller connects across the orifice plate of a meter run to maintain a constant stable pressure differential across the meter run. This relates to a constant flow rate when the upstream or downstream pressure is constant. The pilot adjusts the flow rate to maintain the pressure differential by positioning a pressure opening motor valve with equal percentage valve trim for precise flow control. Applications: Precise gas flow rate for gas lift. Better charts and measurement on meter runs. Stabilizes gas flow for better well production. Differential limiting for reducing “off chart” conditions. Features: 6-10 Intermittent bleed pilot Throttle operation 1 to 260 inches of water differential pressure Heavier spring available (425” H2O) Pilot may be used with many types of diaphragm motor valves SOMETIMES YOU JUST HAVE TO GIVE UP AND ADMIT SUCCESS! The PDC originially started life as an obscure liquid level control pilot before a very creative fellow at Kimray converted one into a Pressure Differential Control. It became one of our top 10 sellers before we had even put it in our catalog! Accessories Supply Gas Regulator SGR Maintains constant downstream pressure. Provides a supply of constant reduced pressure for pneumatic instruments and pilot operated controllers. Features: Easily adjusted Internally relieving Available in Aluminum and 316 Stainless Steel Connections: Sense Line Protector 30 PR Function: An adjustable, self-reseting pressure limiting device to protect instrumentation from over pressurization and subsequent damage. Note: This device is not a regulator. Features: Easily adjusted Internally relieving Inlet and Outlet - 1/4” NPT Connections: Operating Temperature: Inlet and Outlet - 1/4” NPT 0o to 200oF (-18oC to 93oC) Operating Temperature: Maximum Inlet Pressure: 0o to 200oF (-18oC to 93oC) 4000 psi Outlet Pressure: 0 to 125 psi Design Pressure: 1000 psig maximum Output Pressure: Construction Materials: Body: Aluminum or 316 Stainless Steel Diaphragm: Polyurethane Seat: Nylon 300 psig maximum 6-11 Instrument Gas Regulator Sense Line Protector Reduces upstream pressure to pressure appropriate for the valve actuator Protects the pilot from overpressure damage Accessories Drip Pots DP Filters F 30 Function: Removes particulates from gas line. Usually installed in supply line to pilots and regulators. Design Pressure: 300 psig Options: Steel or Stainless steel Drip Pots Available: Material Ductile Iron Steel Steel w/Filter 316 Stainless Max W. P. 300 psig 2000, 4000 psig 2000 psig 2000, 4000 psig Air Motor Bleed Valves: Available in Steel and 316 Stainless Steel as separate item Function: Used to operate shutters on air cooled heat exchangers. Can be used wherever a linear movement produced by a changing pneumatic signal is required. Features: Aluminum housing 5 1/2 inch stroke Operates in any position Stainless steel stem and pins 6-12 Working Pressure: 125 psig Diaphragm Pressure: (Against Spring Load) YOU’RE RIGHT! You are deep into the “Miscellaneous Section.” After 57 years of coming up with solutions we have collected quite an array of items which have repeatedly helped make things work. Call us if you haven’t found the one you are looking for. 1 1/2 psig to start movement 18 psig to fully stroke (Additional pressure required to overcome external load.) Accessories Companion Flange Sets Application: Provides for installation of flanged valves in a threaded piping system. Material: Cast Iron Connections: 2”, 3”, 4” & 6” ANSI 125 Flat Faced Flanges Maximum Operating Pressure: 175 psig Check Valves Sets Include: Material: Steel Flanges, Bolts, Nuts, Gaskets Max. W.P.: 1500 psig Connections: Inlet and Outlet - 1/4”, 3/8”, 1/2” and 1” NPT Springs: Available in 1/4” and 1/2” Standard in 1” 6-13 Here’s some more stuff! Okay, by the time you’ve come to the bottom of this page you may have given up on finding a solution Here’s an idea: CALL US, AND TOGETHER WE’LL FIGURE IT OUT! KIMRAY Solutions ‡® ‡® ‡® ‡® 6-14 TINKER TOYS? Kimray equipment is much more serious than toys, but the stuff is versatile and offers the potential for a broad array of speciallized solutions. CALL US, AND TOGETHER WE’LL FIGURE IT OUT!