MASTER`S THESIS
Transcription
MASTER`S THESIS
CZECH TECHNICAL UNIVERSITY IN PRAGUE FACULTY OF CIVIL ENGINEERING MASTER’S THESIS 2012 FILIP DVOŘÁČEK CZECH TECHNICAL UNIVERSITY IN PRAGUE Faculty of Civil Engineering Department of Special Geodesy Kalibrace elektronických dálkoměrů Diplomová práce Calibration of Electronic Distance Meters Master’s thesis Study program: Study field: Geodesy and Cartography Geodesy and Cartography Supervisors: Ing. Tomáš Jiřikovský, Ph.D. Prof. Martin Vermeer (CTU, Prague) (Aalto University, Helsinki) Filip Dvořáček Prague and Helsinki, 2012 CTU, Aalto, 2012 Abstract and keywords ABSTRACT The theoretical part of the paper is concerned with length measuring methods, especially with electronic distance measurement. Functional principles of electronic distance meters are introduced and velocity corrections to measured distances are described. Further topics deal with errors and calibrations of instruments, uncertainties of measurement and international instructions related to calibrations. The practical part of the paper is concentrated on philosophy, realization and interpretation of calibrations of two electronics distance meters at a calibration baseline called “the Nummela Standard Baseline” in Finland. Last parts compare calibrations at the Nummela standard baseline and at a similar baseline in Koštice in Czech Republic. KEYWORDS Geodesy, Metrology, Electronic distance measurement, Electronic distance meter, Reflecting prism, Accuracy, Calibration, Calibration baseline, The Nummela Standard Baseline, Czech state long distances measuring standard Koštice, Additive constant, Scale correction, Velocity corrections, Uncertainty of measurement, Leica TCA2003, Kern Mekometer ME5000 ABSTRAKT Teoretická část práce se zabývá metodami měření délek, zejména pomocí elektronických dálkoměrům. Uvádí principy elektronického měření vzdálenosti a popisuje fyzikální korekce měřené délky. Dále se věnuje chybám a kalibracím přístrojů, nejistotám měření a mezinárodním předpisům týkajících se kalibrací. Praktická část se pak soustředí na metodiku, provedení a vyhodnocení kalibrace dvou elektronických dálkoměrů na kalibrační základně Nummela ve Finsku. Závěrečná část pak srovnává proces kalibrace na základně Nummela a na státním etalonu velkých délek Koštice v České Republice. KLÍČOVÉ POJMY Geodézie, Metrologie, Elektronické měření délky, Elektronický dálkoměr, Odrazný hranol, Přesnost, Kalibrace, Kalibrační základna, Kalibrační základna Nummela, Státní etalon velkých délek Koštice, Součtová konstanta, Násobná konstanta, Fyzikální redukce, Nejistota měření, Leica TCA2003, Kern Mekometer ME5000 CTU, Aalto, 2012 Announcement ANNOUNCEMENT I declare that I processed this thesis autonomously and that I wrote down all used information sources in unity with the methodical instruction of CTU in Prague number 1/2009 [1]. This master’s thesis has direct relationship to my previous bachelor’s thesis. Therefore some parts of this paper are based on [2]. IN PRAGUE, May 2012 …………………………… Filip Dvořáček CTU, Aalto, 2012 Thanks and support THANKS: For help with the master’s thesis: Ing. Tomáš Jiřikovský, Ph.D. – supervisor, CTU in Prague Prof. Martin Vermeer – supervisor, Aalto University in Helsinki Lic. Sc. Jorma Jokela – Nummela administrator, the FGI Panu Salo – helping surveyor, Aalto University in Helsinki Bc. Petra Stolbenková – helping surveyor, CTU in Prague Mgr. Veronika Krausová – text corrections SUPPORT: This paper could be written thanks to financial support by the Erasmus fund for students going studying abroad. CTU, Aalto, 2012 Contents CONTENTS PREFACE................................................................................................................................. 10 1. 2. INTRODUCTION TO DISTANCE MEASUREMENT ................................................. 12 1.1 Metrology .........................................................................................................12 1.2 Meter as a length unit .......................................................................................13 1.3 Units of temperature, pressure and humidity ...................................................14 1.4 Mathematical reductions ..................................................................................15 1.5 Direct and indirect length measurement ..........................................................16 ELECTRONIC DISTANCE MEASUREMENT ............................................................ 18 2.1 History..............................................................................................................18 2.2 Propagation of electromagnetic waves ............................................................19 2.2.1 The velocity of light ..................................................................................19 2.2.2 The electromagnetic spectrum ..................................................................21 2.2.3 Propagation of different frequencies .........................................................22 2.3 Accuracy ..........................................................................................................23 2.4 Classification of EDM instruments ..................................................................24 2.4.1 Classification according to range ..............................................................24 2.4.3 Classification according to accuracy.........................................................25 2.4.4 Classification according to wavelength ....................................................25 2.5 Principles of the EDM .....................................................................................26 2.5.1 The pulse method ......................................................................................26 2.5.2 The phase difference method ....................................................................27 2.6 The refractive index of air................................................................................28 2.6.1 Barrell and Sears equations .......................................................................29 2.6.2 Error analysis ............................................................................................30 2.6.3 The partial water vapor pressure ...............................................................31 2.6.4 Ciddor and Hill equations .........................................................................32 2.6.5 The coefficient of refraction......................................................................33 2.7 Determination of the refractive index of air ....................................................36 6 CTU, Contents 2.7.1 Normal procedures ....................................................................................36 2.7.2 Limitations of normal procedures .............................................................36 2.7.3 Special procedures ....................................................................................37 2.8 3. Aalto, 2012 Velocity corrections to measured distances .....................................................39 2.8.1 The reference refractive index ..................................................................39 2.8.2 The first velocity correction ......................................................................40 2.8.3 The second velocity correction .................................................................41 CALIBRATION OF EDM INSTRUMENTS ................................................................. 42 3.1 Introduction to calibrations ..............................................................................42 3.2 Errors of instruments........................................................................................43 3.2.1 Overview of errors ....................................................................................43 3.2.2 The zero error and the additive constant ...................................................44 3.2.3 The scale error and the scale correction ....................................................45 3.2.4 Other errors ...............................................................................................45 3.3 EDM calibration baselines ...............................................................................46 3.4 Analysis of measurements ...............................................................................48 3.4.1 Simple linear regression ............................................................................48 3.4.2 Separate computation ................................................................................50 3.4.3 Comparison of methods ............................................................................51 3.5 Uncertainty of measurement ............................................................................52 3.5.1 Introduction ...............................................................................................52 3.5.2 Type A evaluation of standard uncertainty ...............................................54 3.5.3 Type B evaluation of standard uncertainty ...............................................55 3.5.4 Standard uncertainty of the output estimate ..............................................55 3.5.6 Expanded uncertainty of measurement .....................................................57 3.6 Instructions related to EDM calibrations .........................................................57 3.6.1 Standards ISO 17123.................................................................................58 3.6.2 Guide to the expression of uncertainty in measurement ...........................59 3.6.3 Document EA 4/02 ....................................................................................60 3.6.5 Document M3003 ......................................................................................61 3.6.6 Standard ISO/IEC 17025...........................................................................61 7 CTU, 4. Contents 3.6.8 Standard ISO 10012 ..................................................................................62 3.6.9 Standards ISO 9000...................................................................................62 CALIBRATION AT THE NUMMELA BASELINE ..................................................... 64 4.1 The Nummela Standard Baseline.....................................................................64 4.1.1 The Finnish Geodetic Institute ..................................................................64 4.1.2 Baseline description ..................................................................................65 4.1.3 Quartz gauge system .................................................................................67 4.1.4 Interference measurements........................................................................69 4.1.5 Projection measurements ..........................................................................72 4.1.6 Scale transfers to other baselines ..............................................................74 4.2 Instruments and equipment ..............................................................................74 4.2.1 The Leica TCA2003 ..................................................................................74 4.2.2 The Kern Mekometer ME5000 .................................................................76 4.2.3 Other used instruments and equipment .....................................................77 4.3 Measurement ....................................................................................................81 4.3.1 Measurement information .........................................................................81 4.3.2 Measurement procedure ............................................................................82 4.4 Evaluation process ...........................................................................................85 4.4.1 Software ....................................................................................................85 4.4.2 Data pre-processing in Excel ....................................................................86 4.4.4 Data processing in Matlab .........................................................................88 4.4.5 Uncertainties of measurement ...................................................................90 4.4.6 Combining results of calibrations .............................................................93 4.5 5. Aalto, 2012 Results of calibrations ......................................................................................94 4.5.1 The Leica TCA2003 ..................................................................................94 4.5.2 The Kern Mekometer ME5000 .................................................................98 4.5.3 Summary and final results .......................................................................102 4.5.4 Comparison with FGI results ..................................................................104 NUMMELA AND KOŠTICE BASELINES ................................................................. 106 5.1 The Koštice Baseline .....................................................................................106 5.2 Comparison of baselines, measurements and evaluations .............................108 8 CTU, 5.3 Aalto, 2012 Contents Research and development ............................................................................111 CONLUSIONS ....................................................................................................................... 113 BIBLIOGRAPHY .................................................................................................................. 115 LIST OF USED ABBREVIATIONS ..................................................................................... 118 LIST OF FIGURES ................................................................................................................ 119 LIST OF TABELS ................................................................................................................. 120 LIST OF APPENDIXES ........................................................................................................ 121 LIST OF ELECTRONIC ATTACHMENTS ......................................................................... 122 9 CTU, Aalto, 2012 Preface PREFACE The topic of this paper is calibration of electronic distance meters. The problematic of calibrations of EDM instruments is the essential part connecting terrestrial geodesy and length metrology. Since the days of first length measuring instruments, the aim was to calibrate these instruments on more accurate calibration standards and etalons to determine the accuracy traceable to a definition of a length measuring unit. This is the only purposeful way to achieve unification of measuring distances all over the earth. Today, electronic distance meters are the most accurate devices for measuring long distances under field conditions. Therefore calibration has become a real challenge demanding use of state-of-the-art technology, instruments and procedures available. Because EDM instruments are mostly used under field conditions and the measurement is strongly dependent on ambient atmospheric parameters, field calibration procedures offer a way of testing in similar unstable operating conditions. In this case, field calibration baselines are used to compare distances measured with an EDM instrument with more accurate true distances of a calibration baseline. Instrumental corrections can then be evaluated which is the main aim of every calibration. As the principle may seem simple to understand, the whole traceability chain reaching the definition of the meter is extremely scientific and laborious when sufficient accuracy is intended to be achieved. Only in several places in the world, calibrations of the most accurate EDM instruments can be performed with satisfactory low uncertainties. With new technologies entering this field of science in the near future, understanding of present best possible procedures is necessary. The author of this paper performed calibrations of several EDM instruments on the Czech measuring standard Koštice as a part of his bachelor’s thesis [2]. Considering the new baseline, measuring instruments, measuring process and limited amount of time, there was a space for more detailed exploration of problematic of calibrations and for reducing uncertainties. In this paper, calibrations performed at the Nummela Standard Baseline in Finland are described. Introductory chapters may seem sort of extensive, but in fact there are the minimum and the essential parts for understanding the calibration process which is then only an application of previous pieces of knowledge. 10 CTU, Aalto, 2012 Preface The Nummela Standard Baseline is considered to be extremely stable and the most accurate field calibration baseline in the world. It is the only baseline which is regularly measured with the Väisälä interference comparator with about 0.1 mm/km standard uncertainty. The accuracy is fully traceable to the definition of the meter through the quartz gauge system and interference and projection measurements. Two high precision electronic distance meters were calibrated on this baseline by the author. A Leica TCA2003 with accuracy 1 mm + 1 mm/km declared by the manufacturer and a Kern Mekometer ME5000 with accuracy 0.2 mm + 0.2 mm/km. Kern Mekometer ME5000 is known as the most accurate medium range electronic distance meter in the world and very often serves as the scale transfer standard to other geodetic baselines. 11 CTU, Aalto, 2012 1. Introduction to distance measurement 1. INTRODUCTION TO DISTANCE MEASUREMENT 1.1 Metrology A fundamental aim of surveying is the determination of relative positions between two points in space. To fulfill this aim, necessary measurements of important values must be held. In geodesy, there are measurements of lengths and angles. Other additional physical quantities have to be usually measured too (time, temperature, air pressure, humidity, etc.). Results of geodetic measurement should be generally understandable and useable so it is absolutely necessary that measurements have to be proceeded under unified processes, physical quantities must be defined and accuracies of measurements must be declared. Metrology is one of branches of science which deals with these questions. It performs research in fields like physical units and constants, measuring instruments and methods, calibration standards and etalons realisations. A main part of Europe (including the Czech Republic and Finland) is using a quantity system of physical units called Système international d'unités (SI system). In this place, the difference between expressions “accuracy” and “precision” should be explained to exclude any further misunderstandings. The accuracy of a measurement system is the degree of closeness of measurements of a quantity to that quantity's actual (true) value. The precision of a measurement system, also called reproducibility or repeatability, is the degree to which repeated measurements under unchanged conditions show the same results. A measurement system can be accurate but not precise, precise but not accurate, neither, or both. See (Fig. 1) and (Fig. 2) below. Fig. 1: Accuracy vs. precision - graph 12 CTU, Aalto, 2012 1. Introduction to distance measurement High accuracy but low precision Low accuracy but high precision Fig. 2: Accuracy vs. precision - targets Section 1.1 uses bibliography: [2], [3], [4], [5]. The source of used figures: [5]. 1.2 Meter as a length unit History of determining the length scale is very long. Originally it was related with ancient trade when there were no unified rules and every bigger city has its own length unit which was derived from a part of human body (feet), a human activity (step), a natural phenomenon or used measuring instrument. Wide variety in length units led to efforts to derive a length unit from the Earth proportions. Several measurements were held to define one degree of the Earth meridian and the Earth radius. A first step to international unification of length units came from members of Paris Science Academy Jean Charles Borda, Pierre Simon de Laplace and Gaspar Monge in the year 1791. The length unit called meter was accepted as: The ten-millionth part of the meridian quadrant of the Earth reduced to sea level. The result was transferred to a platinum rod with a diameter 25 x 4.05 mm as the final distance 1 m at 0 °C. The name of the length unit was derived from the Greek word metron. Using decimal multiplication and division there was created the metric system of length units. The larger unit is kilometer [km], the smaller unit is millimeter [mm]. Only 20 states of the world accepted this definition at that time but afterwards more of others have joined. Metrological Institute in Sévres in France provided length etalon of 1 meter in a form of ”prototype” for each country (Fig. 3). So there was another definition of meter: Meter is the length between two marks which are in the middle of the prototype in perpendicular position in plane of neutral fibers. 13 CTU, Aalto, 2012 1. Introduction to distance measurement With this method, accuracy of determination of 1 meter was increased from 1 10-5 to 1 10-7 m. Fig. 3: The prototype meter bar of the USA In the year 1960 meter was defined by the wave length of krypton atom: Meter is length equal to 165076373 of wave length of radiation in vacuum which corresponds to the transition between levels 2p10 and 5d5 of atom krypton 86. Today meter is defined by the velocity of light. This definition is valid since 1983. Meter is the length of path travelled by light in a vacuum during 1 / 299 792 458 of a second. Section 1.2 uses bibliography: [2], [3]. 1.3 Units of temperature, pressure and humidity For some length measuring methods it is required to measure also other physical quantities than just distances when high accuracy should be achieved. It is nearly necessary for the method of electronic distance measurement where velocity corrections must be determined. Kelvin [K] is the SI unit for temperature. The kelvin is defined as the fraction 1/273.16 of the thermodynamic temperature of the triple point of water. The scale of Celsius [°C] is more often used in practice. The magnitude of the scale line is the same but the relationship between them is: 0 K 273.15 C 0 C 273.15 K Temperature is measured by the instrument called thermometer. The fundamental SI derived unit of pressure is the Pascal [Pa]. 14 (1.1) CTU, Aalto, 2012 1. Introduction to distance measurement There is a pressure of 1 Pa in space if there is a force per unit area defined as newton per square meter. Other used units are bar [bar] and Torr [Torr]: 1 mbar 1 hPa 1 Torr 1.3332 mbar (1.2) Pressure is measured by the instrument called barometer. Humidity is an essential characteristic of air. We differentiate absolute and relative humidity. Relative humidity is important for determination of air refractive index. Relative humidity of an air-water mixture is defined as the ratio of the partial water vapor pressure in the mixture to the saturated water vapor pressure at a prescribed temperature. Relative humidity is non-dimensional quantity and it is given as a percentage [%]. It is measured by the instrument called hygrometer or it can be computed from psychrometer measurements. Section 1.3 uses bibliography: [2], [3], [6]. 1.4 Mathematical reductions The Earth is physical solid created and maintained in its shape by the gravity and eccentric force. Physical surface is non-homogenous and it is often approximated for geodesy purposes by mathematically defined surfaces such as a sphere and an ellipsoid. These objects are then substituted by surfaces, such as a cone and a cylinder, which can be transformed to a plain. By that approximation some differences in lengths, angles or areas appear. Length reductions from the shape of the Earth are called mathematical reductions. They provide a unified determining of distances on the Earth's surface. Among the mathematical reductions of lengths include sea level reduction and cartographic reduction. To reduce a length longer than about 10 kilometers is much more complicated because there are other reductions which cannot be ignored as for short lengths. In case of calibrations of electronic distance meters it is not necessary to use these reductions completely. A calibration baseline is situated on one certain place where the reductions are always the same values. In addition, we do not need to include these distances into maps. There is only one reduction which can be used when pillars of a baseline are not in a same 15 CTU, Aalto, 2012 1. Introduction to distance measurement height. It is the reduction to constant height, most often to a height of the first pillar. Following formula (1.3) can be used for this purpose to obtain horizontal distances in chosen level. This reduction is often called vertical geometrical correction. s 2 hT hS ds s hS hT 1 1 R R 2 where (1.3) ds … vertical geometrical correction [m] s … slope distance [m] hS … instrument station height above the reference point [m] hT … target height above the reference point [m] R … radius of the Earth [m] Section 1.4 uses bibliography: [2], [3], [7], [8], [9]. 1.5 Direct and indirect length measurement The direct length measurement uses such methods which allow measuring the length directly without need of other intermediate quantities. Very precise measuring rods were used in the past. They were 3.9 meters long, made by iron and zinc, and they were placed one after another to the racks which were holding them. Other direct measuring instruments are invar wires, chains (Fig. 4) and measuring tapes. Measuring tapes are still very often used today. The methods of direct length measurement could be very accurate if they are done with extreme precision and experience of the measurer. Atmospheric conditions must be measured to determine changes of measuring instrument. A disadvantage of these methods is the fact that they are very difficult and time-consuming. 16 CTU, Aalto, 2012 1. Introduction to distance measurement Fig. 4: A measuring metal chain By using indirect length measurement length is determined with help of other intermediate quantities. A most simple method is using a measuring wheel with known perimeter and counting number of its revolutions. In geodesy, there are also several examples of length measuring instruments using indirect measurement. There are mechanical, optical and physical instruments. Not many of them are still used today. But a method of the parallactic angles measurement can be still used for very accurate measurements of short distances. Electronic distance measurement could be covered up by both direct and indirect measurement but more often it is detached separately because of its advanced technology and great importance. Nowadays it is the most often used method of determining distances in geodesy. Electronic distance measurement (EDM for short) is described in following chapter 2. Section 1.5 uses bibliography: [2], [3]. 17 CTU, Aalto, 2012 2. Electronic distance measurement 2. ELECTRONIC DISTANCE MEASUREMENT 2.1 History Historically, the development of electro-optical distance meters evolved from techniques used for determination of the velocity of light described in subsection 2.2.1. According to Zetsche (1979), the first electro-optical distance meter was developed by Lebedew, Balakoff and Wafiadi at the Optical Institute of the USSR in 1936. The Swedish scientist E. Bergstrand designed the first “Geodimeter” (geodetic distance meter) for determination of the velocity of light in 1943. The first commercial instrument Geodimeter NASM-2A (Fig. 5) was produced by the Swedish company AGA and became available in 1950. Long distances could be only measured at night. Fig. 5: Geodimeter NASM-2A An important development was the introduction of the heterodyne technique to electrooptical distance meters by Bjerhammar in 1954, which enabled the execution of more accurate phase measurements at more convenient low frequencies. The first instrument to employ the heterodyne principle was the Geodimeter Model 6A. Subsequently the principle was employed in distance meters of all makes. The use of reflected radiowaves for distance measurements was suggested as early as 1889 by N. Tesla. The first radiowave distance meter (interference principle) was made in 1923. The phase measurement based distance meter (Tellurometer) was developed by T. L. Wadley at National Institute of Telecommunications Research of South Africa in 1954. HeNe lasers incorporating infrared emitting diodes were introduced in EDM in the late 1960’s (Wild Distomat DI10, Tellurometer MA 100, Zeiss SM 11). Further development led to smaller the- 18 CTU, Aalto, 2012 2. Electronic distance measurement odolite-mounted distance meters (Kern DM 500, AGA Geodimeter 12, Topcon DM-C2) and semi-electronic tachometers (Zeiss SM 4, Topcon GTS-1, Sokkisha SDM-3). The first precision EDM instrument, the Mekometer, was built by K.D. Froome and R. H. Bradsell in 1961 at the National Physical Laboratory in Tedington (U.K.) and became commercially available early in 1973 as the Kern Mekometer ME 3000. As a successor Kern Mekometer ME 5000 was released in 1986. The first electronic tachometer (total stations) the Zeiss Reg ELTA 14 was produced from 1970 and it enables electronic readout of distances, vertical and horizontal angles. In 1971 the AGA Geodimeter 700 followed. Smaller and lighter second generation instruments entered the market in 1977 and 1978 with the Hewlett Packard HP 3820A, the Wild TC 1, the Zeiss ELTA 2 and ELTA 4. In the early 1980’s infrared distance meters using the pulse measurement principle appeared on the market. The first instrument for surveying applications, the Geo-Fennel FEN 2000 was released in 1983. The Wild Distomat DI 3000 followed as a second type of pulsed infra-red distance meters in 1985. Section 2.1 uses bibliography: [10]. 2.2 Propagation of electromagnetic waves 2.2.1 The velocity of light The accuracy of an EDM instrument depends ultimately on the accuracy of the estimated velocity of light (or more correctly on the velocity of the electromagnetic wave) in vacuum resp. in the atmosphere. The first estimates of the velocity of light were derived from astronomical observations because very large distances were necessary to produce effects measureable at that time. By studying the times of the eclipses of the satellites of Jupiter, Romer first calculated the value to be 187 000 miles per second in the year 1676. Bradley, in 1727, improved the value by using observations made on the aberration of light received from stars. He obtained the value of 308 000 km/s by measuring the diameter of apparent circle of orbit. In 1849, A. H. L. Fizeau succeeded in making first direct terrestrial measurement. His method is shortly described here as a fundamental principle of determining the velocity of light. The description also demonstrates (Fig. 6). The light source is brought to a focus in the 19 CTU, Aalto, 2012 2. Electronic distance measurement plane of the toothed wheel using the lens and the semi-silvered mirror. Rotation of the toothed wheel causes the light beam to be chopped up into pulses which are then collimated into a parallel beam by another lens. At the distant station about 8.63 km away, the light is reflected back to the instrument by means of the mirror and the lens. The pulses of light, when not cut off by the wheel, could be seen. Now, if the rotation of the wheel is such that the pulse of light produced by the first gap travels the double light path in such a time that on arrival back at the wheel the first tooth is in front of aperture, then no light will be seen by the observer. Fizeau’s 720 teeth cogwheel was spin with angular velocity of 12.6 revolution per second and 313 000 km/s was the estimated velocity of light. Fig. 6: Fizeau’s experiment Later, Foucault employed a rotating mirror in 1862 and Michelson a rotating prism in 1927 for similar experiments. Michelson used a mile-long tube reduced to conditions of low vacuum in order to minimize errors due to atmospheric effects and achieve a value of 299 774 km/s. By 1940, a whole series of experiments had been carried out and Birge computed a weighted mean value for the velocity of light as 299 776 4 km/s. During the Second World War, radar devices using microwaves were introduced into range-finding techniques. Repeated use of these instruments over known distances shows significant difference between visible light and microwaves measurements. Further experiments using Kerr cell and Geodimeter and Tellurometer instruments were in close agreement to the value determined by microwave instruments and cavity resonators. In 1973, the Consultative Committee for Definition of the Meter recommended a value of 299 792 458 use in all practical applications. 20 1.2 m/s for CTU, Aalto, 2012 2. Electronic distance measurement So does the uncertainty of the velocity of light in vacuum effects geodetic measurements? The standard deviations of the velocity of light amounts only 0.004 ppm which is significantly smaller value then EDM instruments can achieve. Since 1983, meter is defined as the length of the path travelled by light in a vacuum in 1/299792458 of a second. As a result of this definition, the velocity of light in vacuum is exactly 299 792 458 m/s and has become a defined constant in the SI system of units. Subsection 2.2.1 uses bibliography: [10], [11], [12]. 2.2.2 The electromagnetic spectrum The electromagnetic spectrum (Fig. 7) is the range of all possible frequencies of electromagnetic radiation. There is an elementary equation (2.1) describing relationship between a frequency of a signal f and a wavelength in a medium in which light has a velocity v. v f Fig. 7: A diagram of the electromagnetic spectrum 21 (2.1) CTU, Aalto, 2012 2. Electronic distance measurement Electromagnetic radiation can be described by the following equation (2.2). where y y A sin t A sin (2.2) t 2 f (2.3) … instant strength of the wave A … amplitude … angular velocity (angular frequency) f … frequency of the signal t … time … phase angle Subsection 2.2.2 uses bibliography: [10], [11], [13]. 2.2.3 Propagation of different frequencies The mode and the velocity of propagation of an electromagnetic wave are dependent on the frequency of the signal and the nature of the Earth’s atmosphere. EDM instruments are capable of measuring path lengths to a very high degree of accuracy, but this information cannot be fully utilized unless the nature of that path is understood. Although EDM instruments use only part of the spectrum from long-waves to visible light, there are some significant differences between propagation of lower frequencies below about 30 MHz and higher frequencies above this value. A low-frequency signal has a direct wave, a ground wave capable of trans-horizon distances, and a reflected wave coming from the ionosphere. Long-range EDM instruments use the ground wave, the reflected wave can cause errors in the measurement. Higher frequency signal has a direct wave, a reflected wave from the ground surface and a scatter signal caused by the atmosphere. EDM instrument using the higher frequencies all use the direct wave, therefore they are limited in range to something less than 100 km. The ground reflection is a nuisance and it is possible source of errors in measurements. In vacuum, all electromagnetic waves propagate with the same velocity, which is the velocity of light. In the atmosphere, the velocity must be always something less than this value due to a density of the atmosphere. The velocity of a signal in a medium (the atmosphere) is 22 CTU, Aalto, 2012 2. Electronic distance measurement also a function of the frequency of the signal. A single electromagnetic wave propagates with a phase velocity. In a real EDM instrument, there is a bunch of near frequencies (also modulated) which are formed in a band propagating through the atmosphere. Each frequency travels with a different velocity and the interference between them occurs. The signal resulting from the sum of all frequencies will have the group velocity which is always smaller than the phase velocities of its individual frequencies. Subsection 2.2.3 uses bibliography: [10], [11]. 2.3 Accuracy In this place, it is necessary to introduce how the accuracy of EDM instruments is mostly often presented because it is important for understanding of following sections. An accuracy of each EDM instrument used for geodetic purposes should be originally declared by its manufacturer. The accuracy of a measured distance is set by the equation (2.4). md a b d where (2.4) md … standard deviation of a measured distance [mm] a … constant [mm] b … constant [mm] d … measured distance [km] It means that the accuracy of the measured distance contains the fixed part and the variable part which is dependent on the measured distance. Constants a and b have characters of standard deviations. Manufacturers should determine these constants according to valid international standards. The constant a is mostly a value between 0.1 and 10 mm, the constant b is mostly a value between 0.2 and 20 mm. More often, following expression (2.5) is used for describing the accuracy of an EDM instrument in general. m a mm b ppm (2.5) Ppm stands for Latin expression pars per milion, resp. English expression parts per million. For example the value 2 mm + 2 ppm means that the accuracy of the EDM instrument is 2 mm plus 2 mm for each kilometer of a measured distance. The accuracy of the distance of 2 km measured with such EDM instrument would be 6 mm. 23 CTU, Aalto, 2012 2. Electronic distance measurement Consider that the constant a includes resolution of the instrument, short periodic errors, non-linear distance-dependent errors, accuracy of initial additive constant and compatibility of reflectors. Constant b includes the drift of the main oscillator within the specified temperature range and the resolution of ppm settings (see section 3.2). This is a mix of random and quasirandom errors with systematic errors which are impossible to separate. The accuracy of an EDM instrument can differ significantly according to specific type and model of the instrument. That is why it is necessarily important for each measurer to know the accuracy of the instrument. Values of constants determined by the manufacturers are not always reliable enough and they are not durable in time. The instruments can achieve significantly better results than which the manufactures declare when they are proper calibrated. Parameters of the EDM instruments can change by reason of improper using, transportation, storage, and age of the instrument. Calibration process serves for checking and rectifying instruments. Section 2.3 uses bibliography: [3]. 2.4 Classification of EDM instruments 2.4.1 Classification according to range Three classes of instruments may be distinguished with respect to range: 1. short range EDM instruments (up to 2 km), 2. medium range EDM instruments (up to 10 km), 3. long range EDM instruments (up to 100 km). Short and medium range instruments are usually used for survey praxis. Long range instruments may have a larger minimum distance. Distances up to 70 km may be measured on clear days with great visibility only, distances up to 100 km and possibly above 100 km may be measured at clear nights. The range does not depend only on an EDM instrument but also on a reflector. Mini-prism, 360° prism, standard prism and several or many joined prism integration, they each reflect different amount of signal and thus affect the final range. 24 CTU, Aalto, 2012 2. Electronic distance measurement 2.4.3 Classification according to accuracy Four categories of instruments may be distinguished with respect to their accuracy. The accuracy is described by the standard deviation of one observation: 1. greater than (5 mm + 5 ppm), 2. equal or smaller than (5 mm + 5 ppm) and greater than (1 mm + 2 ppm), 3. equal or smaller than (1 mm + 2 ppm), and greater than (0.2 mm + 0.2 ppm), 4. equal or smaller than (0.2 mm + 0.2 ppm). Group 1 includes a number of old pulse distance meters and distance measurements to passive or moving targets. The second group of instruments includes most of distance meters found in general surveying practice. Group 3 instruments are often referred to as precision distance meters. Group 4 can be called high precision distance meters and includes the instrument Kern Mekometer ME5000. 2.4.4 Classification according to wavelength EDM instruments may use various frequencies resp. wavelengths of the carrier signal, but not the whole electromagnetic spectrum is suitable for accurate geodetic use. Instruments can be divided into following groups: 1. instruments using long radio waves, 2. instruments using microwaves, 3. instruments using visible light, 4. instruments using infra-red radiation. Long radio waves instruments use the ground wave and suffer from interference from an unwanted sky wave. All can operate over long ranges (hundreds of kilometers) and transhorizon distances, but are not capable of high accuracies (only several meters) because of the surface phase lag effect. The effect can predicted over a homogenous surface such as water, that is why these instruments are used for marine navigation purposes and oceanographic surveys. Group 2 instruments use wavelength from about several centimeters to about several millimeters. Disturbing ground reflection called ground swing is experienced with these instruments because of high divergence of the beam. The range is about 150 km and the accuracy 25 CTU, Aalto, 2012 2. Electronic distance measurement which can be achieved is about 1 cm. These instruments were used in geodesy in the past but now there are not used anymore. Instruments belonging to group 3 and 4 are instruments used in general geodesy nowadays. The direct wave is used for measuring and unwanted reflections are very uncommon as most surfaces found in nature do not produce a strong reflection at this wavelength. The beam is very well collimated. The range is limited by direct visibility, the power of the source and atmospheric conditions. The accuracy of these instruments may be less than 1 mm but the accuracy for longer distances is limited by determining atmospheric conditions. Section 2.4 uses bibliography: [3]. 2.5 Principles of the EDM There are several principles of electronic distance measurement but only some of them are related to terrestrial geodetic measurement. The pulse method and the phase difference method are the ones. The Doppler methods and interferometry are used only for special purposes. The meaning of this section is not to describe the functionality in details, but just provide quick overview of ideas which enable to perform electronic distance measurement. 2.5.1 The pulse method The pulse method is not easy to realize with sufficient accuracy but it is very simple method to understand the principle. A short, intensive signal is transmitted by an instrument. It travels to a target point and back and thus covers twice the distance. By measuring the so-called timeof-flight between transmission and reception of the same pulse, the distance may be calculated as (2.6). d where c v t´ t´ 2n 2 d … distance [m] c … velocity of light in vacuum [m/s] n … refractive index of ambient air t´ … time-of-flight [s] v … velocity of light in ambient air [m/s] 26 (2.6) CTU, Aalto, 2012 2. Electronic distance measurement The flight time is measured by the oscillator. Considering the velocity of light, an extreme accuracy of measuring the flight time is required. To obtain the precision of 3 mm in a measured distance, the precision of 20 picoseconds in time-of-flight is required. The pulse method is frequently used in passive reflecting systems when the pulse is reflected directly from the surface and no reflecting prism is necessary. Some disturbing reflections can be identified and filtered out while analyzing the received pulses. 2.5.2 The phase difference method Historically most important principle which enabled EDM instruments to measure with high accuracy is the phase difference method. Still a lot of today’s instruments use it, regardless of whether they use light waves, infrared waves or microwaves as carrier waves. The measuring signal, which is modulated on the carrier wave in the emitter, travels to the reflector and back to the EDM instrument, where it is picked up by the receiver. In the receiver, the phase of the emitted and the received signals are compared and the phase lead is measured. The emitted signal can be expressed as (2.7), the signal with a phase lead ( ) and corresponding time lead ( t ) can be expressed as equation (2.8). yE A sin t A sin (2.7) yR A sin A sin t t (2.8) Because a continuous signal is used, the values of y change with time, but the phase lead and time lead remain constant. Distance cannot be computed as simple as (2.6) because information about flight time is not obtained through phase comparison. Another equation (2.9) is employed to solve this problem. t´ mt1 t where t´ … flight time of a specific signal [s] m … number of full wavelengths over the path (ambiguity) t1 … elapsed time for one full cycle of the modulation signal (period) [s] t … time lead in phase measurement [s] 27 (2.9) CTU, Aalto, 2012 2. Electronic distance measurement Although the ambiguity is still unknown, other variables can be computed from (2.10). t ; t1 2 v v (2.10) The equation (2.6) can now be written in a new form (2.11) considering relations above. d v v mt1 t m m 2 2 v 2 v 2 2 2 (2.11) Usually, the term (2.11) is simplified by using substitutions as follows (2.12). d mU L where (2.12) U … unit length of a distance meter [m] L … fraction of the unit length U (determined by phase measurement) [m] The ambiguity is solved by the introduction of more than one unit length in an EDM instrument. The precision of an instrument depends on the choice of the main unit length, because of the limited resolution of the phase measurement. Section 2.5 uses bibliography: [3], [10]. 2.6 The refractive index of air The phase refractive index ( n ) of a medium is defined as (2.13). n c vm (2.13) So it is a ratio of the velocity of light in vacuum ( c ) and the phase velocity of the electromagnetic wave in a medium ( ). The variation of the refractive index with frequency causes the phenomenon of dispersion. In EDM equipment we are concerned almost exclusively with the refractive index of air. The refractive index of air is a function of: the gaseous composition of the atmosphere (which is very nearly a constant), the amount of water vapor in the atmosphere, the temperature of the gaseous mixture, the pressure of the gaseous mixture, the frequency of the radiated signal. 28 CTU, Aalto, 2012 2. Electronic distance measurement The refractive index in a single point in space can be determined by the process described in this section below. The most important is to realize that the refractive index is changing with a position on the earth’s surface. So it is also changing along the path of an electromagnetic wave resp. along a measured distance. In the section 2.7 it is described how to deal with this problem. 2.6.1 Barrell and Sears equations The group refractive index ( ng ) is determined rather experimentally than mathematically. Following formula (2.14) according to Barrell and Sears (1939) was derived from experiments at wavelengths ( ) between 436 and 644 nm and it was adopted by IUGG in Berkley in 1963. n g 1.6288 0.0136 1 106 287.604 3 5 2 4 (2.14) It is valid for visible light in standard conditions (dry air, temperature 0 °C, pressure 1013.25 hPa, 0.03 % CO2). is the “effective” wavelength in vacuum in micrometers. Equation (2.14) describes the group refractive index with an accuracy of 0.1 ppm or better. The for- mula can be used to calculate the group refractive index for wavelength to 900 nm (infra-red radiation) with the similar accuracy. The error of 5 nm in the wavelength causes an error of 0.3 ppm in the group refractive index. As we know the group refractive index for standard conditions, the group refractive index for ambient conditions has to be computed. Original formula (2.15) given by Barrell and Sears and simplified version (2.16) are displayed below. nL 1 ng 1 273.15 p 11.27 106 e 273.15 t 1013.25 273.15 t ng 1 p 4.125 108 nL 1 e 1 t 1013.25 1 t where nL … ambient group refractive index for atmospheric conditions t … temperature of air [°C] p … atmospheric pressure [hPa, mbar] … coefficient of expansion of air ( 1/ 273.15 per °C) e … partial water vapor pressure [hPa, mbar] 29 (2.15) (2.16) CTU, Aalto, 2012 2. Electronic distance measurement According to this formula, the group refractive index for standard constructional conditions (reference conditions) and for ambient conditions (conditions of measurement) can be computed. Edge (1960) stated a maximum error of the above equation (2.15) to be 0.2 ppm for temperature range ( 40; 50) °C and pressure range (533; 1067) Torr. Some systematic er- rors of these equations were discussed and more complicated processes were developed to eliminate small systematic errors when they are not tolerable in the most precise electronic distance measurement. Subsection 2.6.1 uses bibliography: [10], [11]. 2.6.2 Error analysis Error analysis of the formula above (2.15) is very important for understanding the importance of measuring atmospheric conditions. The errors of t , p, e may be analyzed by their partial differentials. For a temperature of 15 °C, a pressure of 1007 hPa, a partial water va- por pressure of 13 hPa and a group refractive index of 1.0003045 (a visible light EDM) differentiation of (2.15) looks like (2.17). dnL 106 1.00 dt 0.28 dp 0.04 de (2.17) Notice that an error of a refractive index affects a measured distance by the same value in ppm. The result can be summarized as follows: An error in t of 1.0 °C affects a distance by 1.0 ppm. An error in p of 1.0 hPa affects a distance by 0.3 ppm. An error in e of 1.0 hPa affects a distance by 0.04 ppm. In other words, to obtain an accuracy of 1 ppm of a measured distance, it is required to measure the three quantities with following accuracies (the other two quantities are considered errorless each time): t with accuracy of 1 °C, p with accuracy of 3 hPa, e with accuracy of 25 hPa. Very often, the effect of the partial water vapor pressure is omitted in formulas provided by EDM manufactures. Ignoring the last minuend of the expression (2.15) causes the following errors (Table 1) of a refractive index resp. a measured distance. 30 CTU, Aalto, 2012 2. Electronic distance measurement Table 1: Distance errors caused by omission of humidity Temperature [°C] 0 10 20 30 40 50 where h Errors [mm/km] h 50 % h 100 % 0.1 0.2 0.2 0.5 0.4 0.9 0.8 1.6 1.4 2.8 2.3 4.6 … relative humidity [%] Subsection 2.6.2 uses bibliography: [10], [11]. 2.6.3 The partial water vapor pressure The partial water vapor pressure can be computed from psychrometer measurements. Psychrometer consists of two thermometers, one of which is dry and one of which is kept wet with distilled water. Evaporation of water circulates around the bulb with help of the ventilator and lowers the temperature of “wet bulb” thermometer. The amount of evaporation depends on the humidity of air. From readings of these “wet bulb” and “dry bulb” temperatures, the partial water vapor pressure can be derived (2.18). This formula is accurate to 1 % for °C. e E´ A p t t´ where e (2.18) … partial water vapor pressure [hPa, mbar] E´ … saturation water vapor pressure for t´ [hPa, mbar] A … psychrometer constant [°C-1] (Assman psychrometer: A 0.000662 C1 ) p … atmospheric pressure [hPa, mbar] t … dry bulb temperature [°C] t´ … wet bulb temperature [°C] The values for E´ can be taken from some pre-filled table or can be computed according to Buck (1981) from equation (2.19). Maximum relative error of E´, computed according to (2.19), is less than 0.20 % for 20 °C and 50 °C. 17.502 t ´ E´ 1.0007 3.46 106 p 6.1121 e 240.97t´ 31 (2.19) CTU, where Aalto, 2012 2. Electronic distance measurement E´ … saturation water vapor pressure for t´ [hPa, mbar] t´ … wet bulb temperature [°C] p … atmospheric pressure [hPa, mbar] Another way to determine the partial water vapor pressure is to compute it from relative humidity (2.20). e where Eh 100 (2.20) E … saturation water vapor pressure [hPa, mbar] h … relative humidity [%] E is calculated similar to E´ (2.19) but using dry bulb temperature ( t ) instead of wet bulb temperature ( t´ ). Sufficient accuracy about 0.05 ppm can be achieved for nearly all visible light and infra-red frequency measurements if the relative humidity is measured with the accuracy of 3 % and there is the temperature about 10 °C, there is even lower error about 30 °C. When temperature is about 0.02 ppm. In case of microwave EDM instruments, the use of measured relative humidity causes a significant loss of accuracy in most cases. All calculations above assume that water vapor do not condensate in the air. If it is raining, there are no parts in refractive index formulas which can take it into account. According to experiments, light rain causes a minor error of several hundreds of ppm of a computed refractive index of air. But heavy rain causes a significant error of several tenth of ppm. Subsection 2.6.3 uses bibliography: [10], [11]. 2.6.4 Ciddor and Hill equations Although the Barrell and Sears equations are the best known and still very often used equations, there are newer and more accurate formulas for determining the refractive index of air, for example equations by Edlén, Owens, Peck and Reeder, Jones. Recent measurements proofed significant errors of Barrell and Sears formulas, for example underestimated influence of humidity. At 32nd IAG General Assembly in Birmingham in 1999, a resolution about new formulas according to Ciddor and Hill [14] was adopted because of following reasons: 32 CTU, Aalto, 2012 2. Electronic distance measurement improved accuracy of EDM instruments, new absolute and relative measurements of the refractive index of air, the international temperature scale was revised in 1990, a carbon dioxide content of air has changed since 1963. Following simplified formulas (2.21) and (2.22) are recommended for use in computations of group refractive index of visible light and near infrared EDM instruments. These closed formulas deviate less than 0.25 ppm from the accurate formulae between 30 °C and 45 °C, at 1013.25 hPa and 100 % humidity. N g ng 1 106 287.6155 4.88660 2 0.06800 4 273.15 N g p 11.27 e N L nL 1 106 T 1013.25 T where (2.21) (2.22) N g … group refractivity for standard air N L … group refractivity for ambient air T … thermo-dynamical temperature [K], T 273.15 t Other variables have the same meaning as noted in section 2.6.1. Standard air parameters are the same as for Barrell and Sears equations with the exception of CO2 concentration which is now 0.0375 %. Subsection 2.6.4 uses bibliography: [14], [15]. 2.6.5 The coefficient of refraction It is known from the physics theory that the refractive index of air not only affects the velocity of light but also the geometry of its path. When a wave passes through regions of differing refractive index, the wave path will differ slightly from a straight line. It is because an electromagnetic wave always propagates through a path which takes a minimum time to pass (Fermat’s principle). And it is such a path where the refractive index in each region is the lowest of all regions around. The effect is different for each wavelength because of its different group refractive index. The coefficient of refraction is defined as a ratio of a curvature of a wave path and a curvature of a spheroid along a line (the curvature of the earth’s surface). 33 CTU, Aalto, 2012 2. Electronic distance measurement k where 1/ r R 1/ R r k … coefficient of refraction r … radius of the curvature of the wave path [m, km] (2.23) R … radius of the curvature of the spheroid (radius of the Earth) [m, km] The coefficient of refraction is non-dimensional value. The curvature of the wave path itself can be defined as (2.24). 1 1 n 1 n sin z r n h n h where (2.24) n … vertical gradient of the refractive index of air h z … zenith angle between the direction of the gradient of the refractive index and the tangent to the wave path The change of the refractive index with height is caused by the vertical density gradient of air. Gauss experimentally enumerated the coefficient of refraction for visible light waves and for long-length lines high above ground to the value of 0.13 and this value is very often used for calculations with refraction. But this value may vary considerably under differing atmospheric conditions, for example during night, at sunrise, at sunset and even during the whole day. The variation of the coefficient of refraction increases when the line of sight becomes more close to the ground. For short range EDM instruments the value of 0.13 is worthless for most cases. Following figure (Fig. 8) illustrates the range of values of the coefficient of refraction during one day (Central Europe, summer, clear, calm wind) for different heights of lines above ground (according to Hübner, 1978). 34 CTU, Aalto, 2012 2. Electronic distance measurement Fig. 8: A model of the daily cycle of the coefficient of refraction The coefficient of refraction can be determined by measuring the vertical gradient of refractive index resp. at least vertical temperature gradient. One method of eliminating the influence of the refraction on the measurement is to perform the measurement when there is a minimum of detected refraction resp. when there is a minimal vertical temperature gradient. The value can be also obtained by simultaneous reciprocal zenith angle measurement. But all the techniques of determining the coefficient of refraction require a lot of technical equipment and considerable amount of time. The difference in path length between the theoretical path (line) and more real path (arc, curve) is very small and can be ignored in most cases. This statement is not true for microwave EDM instruments and long distances. The refraction is much bigger problem while measuring zenith angles. Section 2.6.5 uses bibliography: [10], [11]. 35 CTU, Aalto, 2012 2. Electronic distance measurement 2.7 Determination of the refractive index of air In principle, electronic distance measurements should be corrected for the integral refractive index over the entire wave path. This could involve the measurement of temperature, pressure and humidity along the wave path to calculate it. In practice, simplified methods of measurement are usually adopted. However these methods have their limitations. There are also some special methods how to eliminate the refractive index. 2.7.1 Normal procedures The normal procedure of determining the refractive index of air is based on calculations of the representative refractive index of a line computed from meteorological observations at one or both terminals of the line. Whenever high accuracy is required, atmospheric conditions should be measured at both endpoints of the line and the refractive indexes should be computed separately for both terminals. The mean refractive index is then used to correct the measured distance. This procedure provides the best results when only the metrological measurements at the endpoints are considered. There is a way to simplify both the calculation and the measurement. Calculations are simplified by taking the mean of the endpoint meteorological measurements before calculating the representative index of the line. Small errors are introduced in the process due to the non-linearity of the refractive index equations. Only when there are high differences between atmospheric conditions at both endpoints, the error could gain considerable value. Differences of about 7 °C and 100 hPa cause the error of 0.2 ppm. The measurement could be simplified by measuring the metrological data only at the instrument station. Sometimes also humidity is not taken into account. Only these meteorological measurements are then used to calculate the refractive index at the instrument station. As a result of this, temperature and pressure variations over the line are ignored. For example because of the change of pressure with height, systematic error approximately 1.6 ppm per each 100 m height difference between the instrument and the reflector stations is introduced. 2.7.2 Limitations of normal procedures Refractive indexes evaluated from temperature, pressure and humidity readings taken at endpoints represent the integral value over the wave path reasonably well as long as the wave path is parallel to the ground. If the average height of the line above ground exceeds the in- 36 CTU, Aalto, 2012 2. Electronic distance measurement strument and the reflector heights significantly, the mean refractive index no longer closely approaches the integral value over the wave path. The temperature and humidity measurements at the endpoints are strongly influenced by the closeness of the ground. This is called ground proximity effect. The ground proximity effect is the worst during clear sunny days and clear nights. During sunny days there is an unstable stratification of air when there is an upward heat flux. Reduced ground proximity effect is experienced during neutral stratification with no heat transfer between ground and air (zero heat flux) and zero temperature gradient. Near-neutral conditions can be typically observed 1.5 hour after sunrise and 1.5 hour before sunset. Neutral conditions also prevail in heavily overcast weather with moderate to strong wind. Generally speaking, the cloud cover over the wave path and wind significantly reduces the ground proximity effect. All discussed weather conditions above were conditions of homogenous weather along the wave path. Even when there is a linear drift of atmospheric conditions between endpoints of the line, the mean refractive index describes this change very well. However in some cases there are radically different conditions in some regions of the wave path. For example when the wave propagates through areas of direct sunlight and heavy shadows (e.g. wood and meadow) or when it propagates above surfaces with different temperatures (e.g. land and water), the computed mean refractive index is quite an unreliable value. 2.7.3 Special procedures Special procedures were developed to overcome limitations of normal procedures. Special procedures involve instrumental solutions, modeling of the atmosphere (rectification models) and modified field and computing procedures (operational models). Because these methods are not widely used, only short description will be given here. A simple solution for discovering, but much more complicated for realization, is to perform atmospheric measurements along the wave path. It means atmospheric data have to be collected in discrete points of suitable distances between each other along the path. When the line goes near to the ground, only additional measuring instruments and measurers are demanded. When the line goes far above the ground, suitably equipped planes, motor gliders or helicopters are required to carry the airborne instruments. That is why the method is extremely expensive. 37 CTU, Aalto, 2012 2. Electronic distance measurement Another method, which seems to be very effective and less demanding, is to use multiple wavelength EDM instrument. Simultaneous distance measurements with two or three different carrier waves take advantage of the dispersion effect and permit the determination of the difference between two differential refractive indexes. This method leads to a greatly reduced dependency on accurate determinations of atmospheric parameters. In the case of “twocolour” instrument, the distance is derived as following equation (2.25). D dred A dblue dred where (2.25) D … corrected distance [m] d red … distance measured with red laser (HeNe) [m] dblue … distance measured with blue laser (HeCd) [m] A … coefficient dependent on wavelength, pressure and water vapor pressure Due to the coefficient A 21 , the distance difference has to be measured 20 times higher resolution than required in the final distance. But surprisingly good result can be achieved. Experiments showed accuracy better than 0.12 ppm. Unfortunately none multi-color EDM instrument is nowadays commercially available. The endpoint measurements of temperature, pressure and humidity are representative for the atmospheric layer close to the ground. To make these measurements representative for the wave path high above the ground, they need to be transformed. Large number of atmospheric rectification models was developed to describe the low atmosphere. To apply these models, additional information such as height profile, wind speed, sun elevation angle, heat flux, evaporation etc. have to be known. Most models are determined to be used under certain conditions. A suitable atmospheric rectification model certainly determines the mean refraction index with better reliability than no atmospheric model, but the final accuracy is a big question in most cases. There is a direct way how to determine the ambient refractive index directly without measuring the atmospheric conditions. We can obtain refractive index by using instrument called refractometer, which is mostly dual-laser interferometer. The first beam is travelling in vacuum, the second beam in ambient air and the change of the optical length can be measured. Refractometers cannot overcome the limitations of atmospheric measurements and they are not a huge contribution to their accuracy either. However, they are ideally suited for indoor precision EDM instruments and interferometry where there is a uniform but non- 38 CTU, Aalto, 2012 2. Electronic distance measurement standard composition of air. Standard refractive index formulas do not reflect special composition of air. The length ratio method as an operational model solves the problem in a completely different way. When only relative changes are monitored in some geodetic networks and absolute scale is not critical, the measured lines are evaluated by ratio numbers according to their distances. Groups of distances are assigned a common unknown scale parameter. In the adjustment, scale is evaluated only by defining fixed coordinates of two points in network. This method really does not deal with the absolute scale problem but sometimes it can be the cheapest and most efficient solution. Section 2.7 uses bibliography: [10], [11]. 2.8 Velocity corrections to measured distances When it is clear how to compute and how to measure the refractive index of air, it is necessary to know how to apply the correction to a measured distance. Modern total stations can do it instead of us by computing it in an internal firmware. But a user should know how it is done and someone could go through this process manually because of various reasons. For example when humidity cannot be the input to the instrument’s software and you want to take it into account, it is necessary to adopt these computations. Higher accuracy and reliable comparison of results between several instruments can be achieved. 2.8.1 The reference refractive index The reference refractive index is the instrument-specific. It is the specific refractive index for which the EDM instrument provides a correct readout of a distance and it is defined by (2.26). nref where c0 mod f mod nref … reference refractive index c0 … velocity of light in vacuum [m/s] mod … constant modulation wavelength [m] f mod … constant modulation frequency [Hz] 39 (2.26) CTU, Aalto, 2012 2. Electronic distance measurement The reference refractive index is fixed by the manufacturer by adjusting the main oscillator to such a modulation frequency that then the fixed nref corresponds to an average refractive index encountered under field conditions. When field conditions are exactly same as reference conditions than n nref and no refractive index corrections have to be computed. If such details as the modulation wavelength and the modulation frequency are not available for the specific instrument, the reference temperature, pressure and humidity have to be available to compute reference refractive index. Reference conditions are such conditions which correspond to the reference refractive index. It can be computed according to (2.21) and (2.22). 2.8.2 The first velocity correction If field measurements are not performed under conditions which are the same as reference conditions, the first velocity correction must be considered. Different distances can be computed as follows (2.27). d´ where c0 t´ c t´ ; d 0 nref 2 n 2 (2.27) d ´ … distance corresponding to reference conditions [m] d … distance corresponding to ambient conditions [m] t´ … measured “flight” time of the signal [s] n … refractive index for ambient conditions And so the rigorous relationship between distances d and d ´ is the equation (2.28). n d ref n d´ (2.28) However, it is usually preferred to work with a differential equation. The first velocity correction ( K´ ) is then derived according to following process (2.29). K´ d d´ c0 t´ 1 1 c0 t´ nref n nref n d´ 2 n nref 2 nref n n (2.29) Sometimes the first velocity correction is formed as (2.30) when the denominator is set to be equal to 1. This simplification does not introduce error in excess of 0.02 ppm. 40 CTU, Aalto, 2012 2. Electronic distance measurement K´ d´ nref n (2.30) And then the corrected distance is computed as (2.31). d d´ K´ (2.31) 2.8.3 The second velocity correction As mentioned earlier, atmospheric observations are taken normally only at instrument and reflector stations and refractive indexes are computed for both terminals of the line. The mean refractive index is then used for correcting the distance. It would be correct if the wave path would have the same radius as the radius of the earth’s surface. If there is a geodetic refraction expressed with a coefficient of refraction (section 2.6.5) and second velocity correction is not used, a small error is introduced into the distance. Assuming linear vertical gradients of temperature and pressure, the mean refractive index must be corrected as (2.32). n1 n2 n1 n2 d´2 2 n n k k 2 2 12 R 2 where n (2.32) … corrected value of mean refractive index n … correction of the mean refractive index k … coefficient of refraction R … mean radius of curvature of the spheroid along the line [m] The second velocity correction ( K´´ ) may be written as (2.33). K´´ d´ n k k 2 d´3 12 R 2 (2.33) The second velocity correction is more important for microwaves than for light waves and more important on long distances than on short distances. The standard coefficient of refraction 0.13 is very often enumeration of the equation but it is unreliable value in most cases. Computed coefficient of refraction should be used if possible. The final corrected distance is obtained with equation (2.34). d1 d´ K´ K´´ Section 2.8 uses bibliography: [10], [11]. 41 (2.34) CTU, Aalto, 2012 3. Calibration of EDM instruments 3. CALIBRATION OF EDM INSTRUMENTS This chapter should introduced reasons for calibration and some parts of the calibration process itself. Information here is taken from referred bibliography as well as it is inspired by author’s experiences with calibrations of electronic distance meters. 3.1 Introduction to calibrations The calibration of a distance meter is defined as the determination of its instrumental correction and associated accuracy. The instrumental correction is added to a measured distance to obtain the true value of the distance. The instrumental correction is a function of a number of independent variables where the most important is the distance itself, atmospheric conditions and time. To determine instrumental correction, the set of instrument and reflector must be calibrated together. When using another type of reflector, a new calibration is required. Electronic distance meters may be calibrated for a number of reasons. The most important ones are: quality control (at time of purchase and periodically afterwards), improvement of accuracy (achieving more reliable results), legal metrology (required by state or international law). The quality control measurements at the time of purchase have to establish if an instrument fulfills the manufacturer’s specifications such as accuracy, temperature range and distance range. The specified temperature range for the operation of the instrument cannot be easily verified by users. When accurate measurement near the edge of the temperature range must be performed, the user should contact the manufacturer for more information. After the initial quality control, it is advisable to schedule periodic quality control measurements, typically at yearly intervals. The quality control measurements discussed above are a necessity rather than an option and are essential if the specified accuracy should be realized in everyday measurements. But when there is a need to measure with an instrument more accurately, than what is its accuracy specified by its manufacturer, there is the second reason why to calibrate the instrument. The 42 CTU, Aalto, 2012 3. Calibration of EDM instruments accuracy of the instrument can be improved through an extensive calibration and improved field procedures. Sometimes the proper calibration can be same efficient as buying a new instrument which has better accuracy given by the manufacturer. Section 3.1 uses bibliography: [10]. 3.2 Errors of instruments 3.2.1 Overview of errors All electronic distance meters suffer from a large number of errors, irrespective of use of the pulse measurement or the phase measurement principle. Errors are caused by electrical, optical and mechanical principles employed in instruments and by inaccurate manufacturing of them. Magnitudes of these errors are kept small by manufacturers and they are accounted for in the accuracy specifications of instruments. In view of the fact that errors occasionally exceed a specified accuracy and may change with time, users must be aware of unlimited trust in their instruments. Errors can be divided out to random and systematic, instrumental and non-instrumental, periodic and non-periodic, distance-dependent and non-distance-dependent, linear and nonlinear, etc. Lists below demonstrate a number of instrumental and non-instrumental errors. Instrumental errors are for example: additive constant, electrical and optical cross-talk, multipath error, resolution of pulse or phase measurement, phase inhomogeneity and phase drift, frequency errors, error in given carrier wavelength, effect of signal strength. Non-instrumental errors are for example: centering error of reflector, leveling error of reflector, 43 CTU, Aalto, 2012 3. Calibration of EDM instruments reflector pointing, measurement of temperature, pressure and humidity, unwanted reflections from objects other than reflector, atmospheric turbulences. The aim of this section is not to give examination of each error separately. The goal for a user is to understand consequences of errors which can be eliminated by calibration process. 3.2.2 The zero error and the additive constant Because the virtual electro-optical origin or the center of an EDM instrument is usually not located on the vertical axis of the instrument, a small correction has to be added to all distance measurements to refer the distance to the instrument’s vertical axis. This correction is usually called the additive constant and it compensates the dislocation between mechanical and electro-optical centers of the EDM instrument as well as changes of wavelength and velocity of a signal inside the instrument. Similar disproportion between mechanical and optical centers can be found on reflecting prisms. Therefore the additive constant usually summarises effects of all these errors together. Sometimes a term “the zero error” can be used to express similar value as the additive constant. In fact, the zero error is more general term and it is used not only in the EDM field. But there is an important difference. The zero error has an opposite mathematical sign than the additive constant, which means it is a negative value. The additive constant has to be added to a measured distance to obtain the corrected distance but the zero error has to be subtracted from it. The value of the additive constant is originally determined by manufacturers of EDM devices and reflectors and it can amount to several centimeters. The original additive constant is accurate enough for many applications. But the residual additive constant can change with time and it should be determined periodically and applied to all measured distances by either changing the original correction or by adding in postprocessing. Test measurements have shown that the additive constant may also be affected by a number of other parameters. The constant of most distance meters is temperature-dependent. Some instruments were found to show voltage-dependent and signal-strength-dependent additive constants. So it means sometimes dependency between additive constant and measured distance can be discovered, but it is not the main source of errors which should be deeply examined. 44 CTU, Aalto, 2012 3. Calibration of EDM instruments 3.2.3 The scale error and the scale correction Scale errors in EDM instruments are caused primarily by oscillators and by emitting and receiving diodes. Several other factors are contributing to final scale error. The main source of scale error outside the instrument is an incorrect first velocity correction. This problem was discussed in chapter 2. A relationship between the scale error and the scale correction is similar to relationship between the zero error and the additive constant. It means the difference is only an opposite mathematical sign. The most significant oscillator error is its dependency on temperature. Most short range distance meters feature temperature-compensated crystal oscillators as time bases. The frequency versus temperature characteristic of quartz crystal oscillators can be modeled by a third degree polynomial. Because of this phenomenon, short range distance meters are also affected by warm-up effect. It means that an oscillator frequency is dependent on how long the distance meter has been operating. During operation, the distance meter produce heat which warms up the oscillator and causes a change of frequency. The short-term stability of oscillators is usually very good but the long-term stability (ageing) may be up to 1 ppm per year. Diode errors may affect the scale of a distance in several ways. An actual carrier wavelength of the diode’s emission can be different from the nominal value. It causes error in computation of the first velocity correction. The actual carrier wavelength can be temperaturedependent and effect the scale similar way as temperature-dependent oscillator. At last, the linear component of the effect of phase inhomogeneity across the emitting and receiving diode cause scale error of the EDM instrument. Because of all these sources of errors, the scale correction should be periodically determined in calibrations. 3.2.4 Other errors The zero error and the scale error are the most important factors describing an accuracy of an EDM instrument. Monitoring these errors and computation of corrections is an essential purpose of calibrations. Unfortunately not all possible errors can be expressed these ways. There are so called short periodic errors and non-linear distance-dependence errors. Its magnitudes have decreased in modern EDM instruments. Testing of instruments to these errors mostly requires special equipment such as an uncommon design baseline, special conditions such as indoor laboratories and special instruments such as a laser interferometer. 45 CTU, Aalto, 2012 3. Calibration of EDM instruments Short periodic (cyclic) errors can be observed in EDM instruments based on the phase measuring principle. Error with wavelength equivalent to the measuring unit length (first order cyclic error) and its harmonics (higher-order cyclic errors) are mainly cause by electrical or optical cross-talks between the reference and measuring signals. Cyclic errors can be dependent on distance, signal strength, time and others. Some contributions to these errors can be physically explained but certainly not all of them. The final cyclic error is a mixture of a number of different errors. The manufacturers reduce the amplitude of these errors by rigorous electrical shielding, separation of optical channels and special anti-reflex coatings. When numerically determined, the errors can be partly eliminated with introducing corresponding corrections. Sine and cosine functions are used to analyze the pattern of errors. All distance-dependent systematic errors, which are repeatable and reproducible but do not fit above introduced error-classes, may be termed non-linear distance-dependent errors. It includes long-periodic errors as well as non-periodic errors. These errors are most likely caused by inhomogeneities in signals. The reflector moving further and further away from the EDM instrument will collect and return less and less of the signal causing loss of phase information and signal noise. Polynomial expressions of n-th degree are used to model the errors. Section 3.2 uses bibliography: [10], [11]. 3.3 EDM calibration baselines Ideally, an EDM instrument should be calibrated by mounting a reflector on a carriage and moving it on a long straight rail. With the distance meter mounted at the end of the rail, many distances should be measured all over the total working range and instantly compared with a working standard of length. This measurement should be performed in constant atmospheric conditions and it should be repeated at equally spaced temperatures all over the temperature range of the instrument. Whole test should be proceeded periodically to analyze changes of corrections in time. Since this ideal method is technically extremely difficult and would be extremely expensive and prohibitive, simpler and cheaper methods have been developed to obtain results of reasonable quality for corresponding amount of money and time. It is needless to say that the concept described above can be applied for close distances in laboratory conditions, at one temperature only and with laser interferometer as a length stand- 46 CTU, Aalto, 2012 3. Calibration of EDM instruments ard, but unfortunately this is not the complex test of all instrumental errors although it is very precise. As it is generally not practical to test instrumental corrections simultaneously against all variables, separate tests are used to determine one coefficient or group of coefficients. For obvious reasons, the ideal rail approach is usually replaced by a finite number of survey marks (mostly pillars) along a line in outdoor. Such the test-line is typically called the EDM calibration baseline. Calibrations on such test-lines are the main topic of this paper. Field calibration baselines are the most common tools for performing standard calibrations of EDM instruments. They enable to find out the additive constant, the scale correction and sometimes also the cyclic error of an EDM instrument. The additive constant can be determined without knowing baseline’s absolute distances but they have to be known when the scale correction is computed. Special baseline design (Heerbrugg, Aarau, Hobart, etc.) with regard to the instrument’s length unit is needed to analyze the cyclic error. Distances should be evenly spread over the whole measuring range if possible. Extremely stable bottom layer such se bedrock is required to ensure that the distances remain unaffected and stable. Ground marks proofs good stability in time but it is complicated and inaccurate to center instruments above them. On the other hand, pillars are suitable for accurate centering but they show shortterm movements (e.g. temperature, sun) as well as long term movements (e.g. season weather changes). Combination of ground marks and pillars is sometimes applied to take advantages of both stabilizations. Measurement process can differ slightly or significantly dependent on a baseline, an EDM instrument and required accuracy. But here are some notes which should be generally followed: all possible distances should be measured in both ways, the EDM instrument station and the reflector station must be shaded, temperature and air pressure are observed at both stations, wet temperature or relative humidity is measured, the EDM instrument should be tempered at least 15 minutes before measurement, the additive constant is set to zero or employed reflector is chosen, internal ppm correction (the first velocity correction) is set to zero, fine mode of distance measurement should be set, best resolution of distance reading should be chosen, all distances are measured with the same reflector, 47 CTU, Aalto, 2012 3. Calibration of EDM instruments extra precise leveling of instrument and reflector is required, at least four repetition of the measurement of each distance is demanded, determining of heights of instrument and reflector above the pillars is needed. Section 3.3 uses bibliography: [10]. 3.4 Analysis of measurements This section is not focus on pre-processing of measured data. After measurement, raw data have to be prepared for the evaluation. Mostly important, the first velocity correction and geometrical correction are necessary to be applied to means of measured distances. This is descried step by step in section 4.4. Following sub-sections describe possibilities how to evaluate the additive constant and the scale correction if there are true distances and preprocessed measured distances available. 3.4.1 Simple linear regression In statistics, linear regression is an approach to modeling the relationship between a scalar variable y and one or more explanatory variables denoted X. The case of one explanatory variable x is called simple regression and the case of more than one explanatory variable X is called multiple regression. In linear regression, data are modeled using linear functions and unknown model parameters are estimated from the measured data. Such models are called linear models. Most commonly, linear regression refers to a model in which the mean of y at the given value of x is an affine function of x. Simple linear regression, as well as regression analysis in general, focuses on the probability distribution of y at given x. Values x are considered to be true values without errors. Analysis of joint probability distribution of y and x is the domain of multivariate analysis. Linear regression models are often fitted using least squares approach (ordinary least squares). Summarized, simple linear regression is the least squares estimator of a linear regression model with a single explanatory variable. In other words, simple linear regression fits a straight line through the set of n points in such a way that makes the sum of squared residuals of the model as small as possible. Residuals are called vertical distances between points of the data set and the fitted line. The line can be expressed as follows (3.1). 48 CTU, Aalto, 2012 3. Calibration of EDM instruments y x where y … dependent variable x … explanatory variable … coefficient (intercept term) … coefficient (slope term) (3.1) The sum of squares of residuals is as (3.2). n S , xi yi 2 (3.2) i 1 Partial derivations are set to be equal to zero for finding the minimum (3.3). n S 2 xi yi 0 i 1 n S 2 xi yi xi 0 i 1 (3.3) By re-arranging equations, we can obtain (3.4). n n n xi xi2 xi yi i 1 i 1 i 1 n n i 1 i 1 n n (3.4) n xi yi And the final solution is as (3.5). n i 1 2 i i 1 i i 1 i i 1 2 n n n xi2 xi i 1 i 1 n n x y x x y n n n xi yi xi yi i 1 i 1 i i (3.5) i 1 2 n xi2 xi i 1 i 1 n n Implementation of this statistical tool to calibration of EDM instruments is obvious. Values x represent baseline true distances and values y measured distances. Even more suitable is to set y values as differences between true and measured distances (true - measured). Therefore α represents the additive constant and β represents the scale correction of calibrated EDM instrument. Standard deviations of coefficients may be computed. A correlation coefficient, 49 CTU, Aalto, 2012 3. Calibration of EDM instruments which can show amount of dependency between variables, is not very suitable for this application of simple linear regression. Much more interesting is calculation of the root mean square deviation (RMSD) which indicates how observations are distributed along the regress line. n RMSD where r … residuals n … number of residuals r 2 i i 1 n (3.6) The simple linear regression is very sensitive to outliers. Even the only one false value in the set of observations strongly affects the results. There are some advanced robust methods how to deal with this problem. Robust methods take into account the residuals to weigh the observations. But since there is a relatively small number of measurements in EDM calibrations, and outliers are not very frequented phenomena, it is not necessary to use robust methods. In addition, the results would be affected by some measurements more than others which is not the right thing in most cases. To use a regress line as a regression model is very advantageous. Coefficients of a line can be used as instrumental corrections. But also more complex curve can be used as a regression model to fit the observed data better. Quadratic, cubic and higher-level polynomial lines can be used for this purpose. RMSD error will slightly decrease, when higher polynomial is used, but it become much more complicated to apply computed corrections. This is used mostly in experimental applications. Methods, computing both instrumental corrections altogether, will be called “combined methods” later in this paper. 3.4.2 Separate computation There is also a different way how to deal with an evaluation of measurements. Beside simple linear regression, separate computation of the additive constant and the scale correction can be applied. Pros and cons of both methods are discussed in following subsection 3.4.3. Socalled separate computation determines the additive constant using measured distances and the least squares adjustment. The scale correction is then determined using corrected measured distances, baseline true distances and simple linear regression without the intercept term. 50 CTU, Aalto, 2012 3. Calibration of EDM instruments In the first step, the additive constant is calculated by the least squares adjustment (LSA). Input values for the adjustment are means of measured distances with applied corrections such as the first velocity correction and the geometrical correction. Unknown variables are distances between pillars and the additive constant. An initial standard deviation of one measured distance may be set according to accuracy specified by the manufacturer of the instrument. All observations are usually equally weighted. No observations are rejected. The standard LSA is then computed. As one of results, the additive constant is obtained. A standard deviation of the additive constant is then computed using a covariance matrix. In the second step, the scale correction is evaluated using modified simple linear regression. The modification consists in omission of the intercept term. Modified regression model looks like equation (3.7). yx (3.7) Derivation of the final solution (3.10) is similar to ordinary simple linear regression. n S xi yi 2 (3.8) i 1 n S 2 xi yi xi 0 i 1 (3.9) n x i 1 n yi i x i 1 (3.10) 2 i RMSD and other statements introduced in subsection 3.4.1 are equally valid for simple linear regression without the intercept term. 3.4.3 Comparison of methods Simple linear regression may seem as the best way to evaluate measurements. It is wellknown, easy and it solves all together. But even if the estimate of corrections for particular set of observations is the best possible with this method, there is a serious doubt if this computation is completely suitable for calibrations of EDM instruments. Employing simple linear regression in the evaluation process leads to calculating both corrections together without respecting their initial definitions. The computed constants can be hardly called the additive constant and the scale correction since each of them is a mixture of both. The contributions 51 CTU, Aalto, 2012 3. Calibration of EDM instruments cannot be recognized in results and they cannot be separated. That makes impossible to trace differences in corrections in time. On the other hand, separate computation respects geodetic meaning of corrections. The additive constant is computed separately using only measured distances. True baseline distances are not needed. Measured distances are corrected for computed additive constant and then the scale correction is computed as simple linear regression without the intercept term. That makes proper separation of constants which can be now called the additive constant and the scale correction in a geodetic meaning. But this separate calculation does not give the best possible results in a mathematic sense. There is always some small residual error which is not covered by this computation and the constants do not fit for the particular set of measurements as well as if they are evaluated using ordinary simple linear regression. The difference in these two methods is not very large but it is significant. The difference is not the same for a specific EDM instrument and it differs according to each set of measurements. The most interesting is the comparison of RMSD of both methods. RMSD of simple linear regression is always smaller than RMSD of separate computation but the difference is insignificant in most cases. That is why the differences in corrected distances (resp. residuals) are insignificant using both methods even if the differences in constants may be significant. The difference in the additive constant is always largely compensated in the scale correction. In spite of this small accuracy disadvantage, the separate computation has a big advantage which is the traceability of corrections in time. Section 3.4 uses bibliography: [2], [10], [16], [17], [18]. 3.5 Uncertainty of measurement 3.5.1 Introduction The term “uncertainty of measurement” was established to uniform the terminology. “The uncertainty of measurement is a parameter, associated with the result of a measurement, that characterizes the dispersion of the values that could reasonably be attributed to the measurand.” Quoted from [19]. The measurand is the particular quantity to be measured. The term “uncertainty of measurement” is sometimes used only as “uncertainty” but it may have also another meaning. In metrology, the term “error” does not mean the same thing as “uncertain- 52 CTU, Aalto, 2012 3. Calibration of EDM instruments ty”. Uncertainty is a quantification of the doubt about the measurement result while error is the difference between the measured value and the true value of the object being measured. The importance of determining uncertainties should be obvious. No result can be considered understandable without the associated uncertainty. Errors and uncertainties come from very different sources which all have to be examined and uncertainties estimated. In a measuring process, the sources may be such follows: the measuring instruments (EDM instrument, reflector, thermometer, barometer, …), the item being measured (calibration baseline), the measurement process (measurement procedure), imported uncertainties (projection correction, instrument calibrations), operator skill (measurer), the environment (atmospheric conditions), sampling issues (atmospheric conditions determined at a wrong place). Determining of uncertainties is very individual because it depends on many variables and sometimes also on personal experience or a subjective attitude of the evaluator. Some of the most important instructions related to uncertainty of measurement are presented in section 3.6. The most essential instruction in this field is the GUM [20] presented in subsection 3.6.2. The simplified document, desired to be used by calibration laboratories, is the document EA 4/02 [19] presented in subsection 3.6.3. Further explanations and notations respect rather the document EA 4/02 than the GUM if there are small variances between them. In calibration, one usually deals with only one measurand or output quantity Y (corrected distance) that depends upon a number of input quantities (distance, temperature, pres- sure, …) according to the function relationship (3.11). Y f X1 , X 2 , ..., X n The model function (3.11) represents the procedure of the measurement and the method of evalu- ation. It describes how values of the output quantity are obtained from values of the input quantities. The set of input quantities may be grouped into two categories according to the way in which the value of the quantity and its associated uncertainty have been determined: Quantities whose estimate and associated uncertainty are directly determined in the current measurement. 53 CTU, Aalto, 2012 3. Calibration of EDM instruments Quantities whose estimate and associated uncertainty are brought into the measurement from external sources. For a random variable, the variance of its distribution or the positive square root of the variance, called standard deviation, is used as a measure of the dispersion of values. “The standard uncertainty of measurement” associated with output estimate or measurement result , denoted by the estimates , is the standard deviation of the measurand . It is to be determined from of the input quantities and their associated standard uncertainties . 3.5.2 Type A evaluation of standard uncertainty The type A evaluation of standard uncertainty can be applied when several independent observations have been made for one of the input quantities under the same conditions of measurement. If there is a sufficient resolution in the measurement process, there will be an observable scatter or spread in the values obtained. Assume that the repeatedly measured input quantity the quantity is the arithmetic mean ̅ (3.12) of q is the quantity . The estimate of individual observed values 1 n qj n j 1 . (3.12) An estimate of the variance of the underlying probability distribution is the experimental variance that is given by (3.13). s2 q 2 1 n qj q n 1 j 1 (3.13) Its positive square root is termed “the experimental standard deviation”. The best estimate of the variance of the arithmetic mean ̅ is “the experimental variance of the mean” given by (3.14). s2 q s q n 2 (3.14) Its positive square root is termed “experimental standard deviation of the mean”. The standard uncertainty ̅ associated with the input estimate ̅ is the experimental standard deviation of the mean ̅ (3.15). u q s q 54 (3.15) CTU, Aalto, 2012 When a number of 3. Calibration of EDM instruments of repeated measurements is low, the reliability of a type A evalu- ation of standard uncertainty has to be considered. If the number of observations cannot be increased, other methods have to be taken into account. “Pooled estimate of variance” based on a long statistical control or experience may be available. This pool estimate of variance should characterize the dispersion better than the estimated standard deviation obtained from a limited number of observations. The variance of the mean may be estimated by (3.16) and the standard uncertainty of the mean is deduced from (3.15). s2 q s 2p (3.16) n 3.5.3 Type B evaluation of standard uncertainty The type B evaluation of standard uncertainty is the evaluation of the uncertainty associated with an estimate of an input quantity by means other than the statistical analysis of a series of observations. The standard uncertainty is evaluated by scientific judgment based on all available information on the possible variability of . Values belonging to this category may be derived from: previous measurement data, experience with or general knowledge of the behavior of instruments and materials, manufacturer’s specifications, data provided in calibration and other certificates, uncertainties assigned to reference data taken from handbooks. The proper use of the available information for a type B evaluation of standard uncertainty of measurement calls for insight based experience and general knowledge. It is a skill that can be learned with practice. 3.5.4 Standard uncertainty of the output estimate In the GUM [20], the standard uncertainty of the output estimate, obtained by combining type A and type B evaluation of standard uncertainty, is defined as “combined standard uncertainty”. In the EA 4/02 [19], there is no mention about combined standard uncertainty since both types of uncertainties are considered to be equally valid and more suitable one is always picked to be used for the particular input quantity 55 . CTU, Aalto, 2012 3. Calibration of EDM instruments For uncorrelated input quantities the square of the standard uncertainty associated with the output estimate resp. the measurement result is the sum of squares given by (3.17). N u 2 y ui2 y (3.17) i 1 The standard uncertainty the output estimate estimate is the contribution to the standard uncertainty associated with resulting from the standard uncertainty associated with the input according to (3.18). ui y ci u xi where ci (3.18) … sensitivity coefficient The sensitivity coefficient is the partial derivative of the model function evaluated at the input estimates with respect to (3.19). It describes the extent to which the output estimate is influenced by variations of the input estimate ci f f xi X i . (3.19) X1 x1 ... X N xN The uncertainty analysis for a measurement, sometimes called the uncertainty budget of the measurement, should include a list of all sources of uncertainty together with the associated standard uncertainties of measurement and the methods of evaluating them. It is recommended to present the data relevant to this analysis in the form of a table containing: quantity type of evaluation of standard uncertainty, associated standard uncertainty of measurement the sensitivity coefficient uncertainty contribution , referenced by a physical symbol, , , . The dimension of each of the quantities should be also stated with the numerical values in the table. In the bottom right corner of the table, the standard uncertainty associated with the measurement result is given. 56 CTU, Aalto, 2012 3. Calibration of EDM instruments 3.5.6 Expanded uncertainty of measurement Within EAL (Evaluation Uncertainty Assurance) it has been decided that calibration laboratories accredited by members of the EAL should state an “expanded uncertainty of measurement”, denoted by U. The expanded uncertainty is obtained by multiplying the standard uncertainty by a “coverage factor” k (3.20). U k u y (3.20) In cases where a normal (Gaussian) distribution can be attributed to the measurand and the standard uncertainty associated with the output estimate has sufficient reliability, the standard coverage factor 2 shall be used. The assigned expanded uncertainty corresponds to a cov- erage probability of approximately 95 %. If there is a reasonable doubt about reliability of the standard uncertainty associated with output estimate see the document EA 4/02 for more details [19]. In calibration certificates, the complete result of the measurement consisting of the estimate y of the measurand and the associated expanded uncertainty U should be given in the form ( y ± U ). To this an explanatory note must be added which in the general case should have the following content: The reported expanded uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by the coverage factor 2, which for a normal distribution corre- sponds to a coverage probability of approximately 95 %. The standard uncertainty of measurement has been determined in accordance with EAL Publication EAL-R2. Section 3.5 uses bibliography: [19], [20], [21]. 3.6 Instructions related to EDM calibrations This section is not meant to be a detailed description of legal instructions related to EDM calibrations. Such a topic is a very wide one and it is not the main focus of this paper. Reading of a specific instruction is always unavoidable for proper understanding. This overview is giving brief outlook in questions of legal background of calibrations of EDM instruments. 57 CTU, Aalto, 2012 3. Calibration of EDM instruments 3.6.1 Standards ISO 17123 Standards ISO 17123 bear common title “Optics and optical instruments – Field procedures for testing geodetic and surveying instruments.” There are eight parts of the ISO 17123 standards. Part 1: Theory Part 2: Levels Part 3: Theodolites Part 4: Electro-optical distance meters (EDM instruments) [22] Part 5: Electronic tachometers Part 6: Rotating lasers Part 7: Optical plumbing instruments Part 8: GNSS field measurement systems in real-time kinematic (RTK) “Standards ISO 17123 specify only field test procedures for geodetic instruments without ensuring traceability in accordance with ISO/IEC Guide 99. For the purpose of ensuring traceability, it is intended that the instrument be calibrated in the testing laboratory in advance.” Quoted from [23]. Standards are primarily intended to be used in engineering geodesy as the control tool for checking suitability of instruments for intended use. Test procedures are designed to be applied without special additional equipment and to minimize atmospheric influences. Statistical tests for evaluating significance of results are present. Part 1 and part 4 are those most related to the topic of calibrations of EDM instruments. “ISO 17123-1 gives guidance to provide general rules for evaluating and expressing uncertainty in measurement for use in the specifications of the test procedures described in following parts.” Quoted from [23]. The following part 4 is dealing with testing of electronic distance meters. Two different testing procedures are described – simplified test and full test. A fundamental limitation of both of these procedures is a fact that they do not allow to detect additional instrumental corrections. Accuracy and precision are tested as a complex feature of an instrument without the aim of determining the additive constant and the scale correction. Therefore the tests are not calibrations since no corrections can be obtained. Only additive constant can be determined using full test but the main aim is still to determine experimental standard deviation. 58 CTU, Aalto, 2012 3. Calibration of EDM instruments The simplified test works with reduced amount of measurements. The purpose is to find out if differences between true and measured distances are inside an accepted interval determined by according to a standard ISO 4463-1. Calibration field or another precise EDM instrument is required to run this test. From certain station, distances to other four points are measured three times. Points are distant from about 20 to about 200 meters and they do not have to be formed in a line. Mean distances and differences (true - measured) are computed. If differences do not fit into the interval , analyses of results must be performed. If there is systematic error, additional instrumental corrections should be checked in certified calibration laboratory. If there is not an obvious systematic error, full test procedure is recommended to be carried out. Full test should provide more accurate estimation of the experimental standard deviation of a tested instrument. Distances between all combinations of seven points in a line of 600 meters are measured in forward direction only. True distances are not needed and remain unknown in this test therefore no information about the scale can be derived. Seven points of a line are placed according to a carrier wavelength of the tested instrument. Calculation is based on a simple least squares adjustment with distances and an additive constant as unknown variables. Adjusted distances and corresponding standard deviations are not evaluated. The experimental standard deviation of the instrument is determined using residuals of all measured distances. s where r … residuals v … degrees of freedom r 2 v (3.21) 3.6.2 Guide to the expression of uncertainty in measurement The GUM (Guide to the expression of uncertainty in measurement) is an essential document dealing with uncertainties of measurement. Guide was written in 1995 with minor corrections in 1998 by the JCGM (Joint Committee for Guides in Metrology) member organizations (BIPM, IEC, IFCC, ILAC, ISO, IUPAC, IUPAP and OIML). Full name of the document is “Evaluation of measurement data – Guide to the expression of uncertainty in measurement.” In 2009, JCGM published related publication named “Evaluation of measurement data – An introduction to the Guide to the expression of uncertainty in measurement and related docu- 59 CTU, Aalto, 2012 3. Calibration of EDM instruments ments”. The GUM is freely available on the BIMP website [20]. Section 3.5 respects this guide. The aim was: “To develop a guidance document based upon the recommendation of the BIPM Working Group on the Statement of Uncertainties which provides rules on the expression of measurement uncertainty for use within standardization, calibration, laboratory accreditation, and metrology services. The purpose of such guidance is to promote full information on how uncertainty statements are arrived at and to provide a basis for the international comparison of measurement results.” Quoted from [20]. 3.6.3 Document EA 4/02 This document is a publication of the EA (European co-operation for Accreditation). Full name of the document is “Expression of the Uncertainty of Measurement in Calibration”. This document is freely available on websites of the EA [19]. Section 3.5 respects this document. “The purpose of this document is to harmonize evaluation of uncertainty of measurement within EA, to set up, in addition to the general requirements of EAL-R1, the specific demands in reporting uncertainty of measurement on calibration certificates issued by accredited laboratories and to assist accreditation bodies with a coherent assignment of best measurement capability to calibration laboratories accredited by them. As the rules laid down in this document are in compliance with the recommendations of the Guide to the Expression of Uncertainty in Measurement, published by seven international organizations concerned with standardization and metrology, the implementation of EA-4/02 will also foster the global acceptance of European results of measurement.” Quoted from [19]. In first parts of the document, terms such as standard uncertainties type A and B and expanded uncertainty are defined. These parts are very similar to GUM. In following appendixes, more terms are explained. In the most extensive part, there are supplements with examples of calibrations of several different instruments. Even if the document is very useful reading to familiarize the problematic of uncertainties of measurements, there is no suitable example of calibrating an EDM instrument. In spite of the document should be practical example of how to evaluate uncertainties of measurement, it cannot cover the whole range of instruments and calibration specifics. In these cases, contacting the EA organization is advised. 60 CTU, Aalto, 2012 3. Calibration of EDM instruments 3.6.5 Document M3003 Document M3003, named “The Expression of Uncertainty and Confidence in Measurement”, is published by the UKAS (United Kingdom Accreditation Service). Second edition is freely available since January 2007 on websites of the UKAS [24]. Same as the document EA 4/02, the M3003 is based on information in the GUM. “The purpose of these guidelines is to provide policy on the evaluation and reporting of measurement uncertainty for testing and calibration laboratories. Related topics, such as evaluation of compliance with specifications, are also included. A number of worked examples are included in order to illustrate how practical implementation of the principles involved can be achieved.” Quoted from [24]. 3.6.6 Standard ISO/IEC 17025 International standard ISO/IEC 17025:2005 named “General requirements for the competence of testing and calibration laboratories” was developed by organizations IAF, ILAC and ISO. Unless the instruction is not intended to be used as the basis for certification of laboratories, it is sometimes used as one of requirements. The certification process is very expensive and therefore it is adopted only by professional laboratories. The standard is not freely available and was not owned by the author while writing this paper. “ISO/IEC 17025:2005 specifies the general requirements for the competence to carry out tests and/or calibrations, including sampling. It covers testing and calibration performed using standard methods, non-standard methods, and laboratory-developed methods. It is applicable to all organizations performing tests and/or calibrations regardless of the number of personnel or the extent of the scope of testing and/or calibration activities. When a laboratory does not undertake one or more of the activities covered by ISO/IEC 17025:2005, such as sampling and the design/development of new methods, the requirements of those clauses do not apply. ISO/IEC 17025:2005 is for use by laboratories in developing their management system for quality, administrative and technical operations. Laboratory customers, regulatory authorities and accreditation bodies may also use it in confirming or recognizing the competence of laboratories.” Quoted from [25]. 61 CTU, Aalto, 2012 3. Calibration of EDM instruments 3.6.8 Standard ISO 10012 International standard ISO 10012:2003 named “Measurement management systems - Requirements for processes and measuring equipment” is the revised standard of ISO 100121:1992 and ISO 10012-2:1997. ISO 10012:2003 is not intended as a substitute for or as an addition to the requirements of ISO/IEC 17025. And it is not intended to be used as a requisite for demonstrating conformance with ISO 9001. Interested parties can agree to use ISO 10012:2003 as an input for satisfying measurement management system requirements in certification activities. It can be used to create a metrological confirmation system in a company. The standard is not freely available and was not owned by the author while writing this paper. “ISO 10012:2003 specifies generic requirements and provides guidance for the management of measurement processes and metrological confirmation of measuring equipment used to support and demonstrate compliance with metrological requirements. It specifies quality management requirements of a measurement management system that can be used by an organization performing measurements as part of the overall management system, and to ensure metrological requirements are met.” Quoted from [26]. 3.6.9 Standards ISO 9000 The ISO 9000 family of standards represents an international consensus on good quality management practices. It consists of standards and guidelines relating to quality management systems and related supporting standards. The ISO 9000 family of standards is named “Quality management systems” and there are three main parts. ISO 9000:2005 – Fundamentals and vocabulary ISO 9001:2008 – Requirements ISO 9004:2009 – A quality management approach ISO 9001:2008 is implemented by over a million organizations in 176 countries. All requirements are generic and are intended to be applicable to all organizations, regardless of type, size and product provided. Where any requirement(s) of ISO 9001:2008 cannot be applied due to the nature of an organization and its product, this can be considered for exclusion. 62 CTU, Aalto, 2012 3. Calibration of EDM instruments “ISO 9001:2008 specifies requirements for a quality management system where an organization: needs to demonstrate its ability to consistently provide product that meets customer and applicable statutory and regulatory requirements, aims to enhance customer satisfaction through the effective application of the system, including processes for continual improvement of the system and the assurance of conformity to customer and applicable statutory and regulatory requirements. Quoted from [27]. Quality management systems are also concern calibration laboratories as well as geodetic companies. Anyone who would like to proof that the quality management system of a company is in conformity with ISO 9000 family of standards has to pass through a certification process organized by an independent certification body. The certification is very expensive and following paid audits are necessary. Therefore every company must calculate pros and cons of ISO 9000 certification. The standards are not freely available and were not owned by the author while writing this paper. Section 3.6 uses bibliography: [2], [19], [20], [21], [22], [23], [24], [25], [26], [27]. 63 CTU, Aalto, 2012 4. Calibration at the Nummela baseline 4. CALIBRATION AT THE NUMMELA BASELINE 4.1 The Nummela Standard Baseline 4.1.1 The Finnish Geodetic Institute The Finnish Geodetic Institute, as the name predicates, is an organization dealing with geodesy. It is a research institute of the Ministry of Agriculture and Forestry of Finland specializing in geodesy and geospatial information, science and technology. It was founded in the year 1918, its residence is situated in Masala, twenty-five kilometers west of Helsinky. The FGI has personnel of about eighty people in five departments: Geodesy and Geodynamics, Geoinformatics and Cartography, Remote Sensing and Photogrammetry, Navigation and Positioning, Administration Services. Department of Geodesy and Geodynamics is concerned with reference frames, height systems, geoid models, crustal deformation and metrology. It operates the Metsähovi Fundamental Geodetic Station with advanced measuring methods such as: VLBI, SLR, GNSS, DORIS, AG, SCG. This department also includes National Standards Laboratory of Acceleration of Free Fall and National Standards Laboratory of Length. National Standards Laboratory of Length deals with calibration of geodetic instruments such as electronic distance meters and leveling rods. It operates calibration laboratory for precise-leveling and digital leveling systems, test field for leveling and Nummela baselines (the Nummela Standard Baseline, the Nummela Calibration Baseline). The Nummela Calibration Baseline is derived from the Nummela Standard Baseline using high-precision EDM instruments and it is opened to public. Subsection 4.1.1 uses bibliography: [28]. 64 CTU, Aalto, 2012 4. Calibration at the Nummela baseline 4.1.2 Baseline description The Nummela Standard Baseline of the FGI is a unique national and international measurement standard for length measurements in geodesy. In 1933 a new baseline was established in Nummela, 45 km NW of Helsinki, on a frost-resistant ridge of moraine and sand with glacial origin covered with pine forest. The design was fitted for comparison of invar wires (36 x 24 m = 864 m). Later, the baseline was equipped for the Väisälä interference comparator and since the first interference measurements in 1947 it has been called the Nummela Standard Baseline. All observation pillars are placed on the same line in space. The height difference from 0 m to 864 m is -4.1 m. Today it consists of 6 benchmark bolts in underground concrete blocks at 0, 24, 72, 216, 432 and 864 meters which are generally called underground markers (Fig. 9). 6 observation pillars (Fig. 10) with Kern-type forced-centering are situated alongside underground markers. Unique dismountable Kern centering plates completes the centering system (Fig. 11) for purpose of fixing standard geodetic equipment. Aboveground pillar constructions were recently reconditioned in 2007. Fig. 9: The underground marker at 24 m 65 CTU, Aalto, 2012 4. Calibration at the Nummela baseline Fig. 10: The observation pillars at 0 m (left) and 864 m (right) Fig. 11: The Kern-type forced-centering system 66 CTU, Aalto, 2012 4. Calibration at the Nummela baseline The traceability from the definition of the meter to a distance of the baseline is provided through the quartz gauge system and measurements with the Väisälä interference comparator. Importance of Väisälä standard baselines was acknowledged already in 1951 by the IAG General Assembly and in 1954 by the IUGG, which recommended such measurements in different countries all around the world. At the Nummela Standard Baseline, 15 interference measurements during 1947-2007 verified traceability and extreme stability of the baseline. For the length of 864 m, all results during 60 years are within 0.6 mm, latest total standard uncertainty for this distance is 0.08 mm. Results of interference measurements is preserved in length between underground markers, which can be accessed and utilized through regular theodolite-based projection measurements and observation pillars. Subsection 4.1.2 uses bibliography: [8], [29], [30], [31]. 4.1.3 Quartz gauge system A measurement of a baseline with the Väisälä interferometer is a high accuracy length measurement in geodesy. An accurate length up to 1 km is achievable by interferometrically multiplying the length of a 1 m quartz bar. Therefore, the absolute length of the bar should be known with small uncertainty. A measurement setup and procedure for absolute length calibration of a quartz bar by combined white and laser light gauge block interferometer has been developed. A standard uncertainty of 35 nm has been achieved with these methods by Tuorla Observatory. The system of tens of quartz meters (Fig. 12) has been maintained for more than 70 years. The lengths are determined through repeated comparisons and absolute calibrations. The most commonly used quartz gauges are 1 m long, 23 mm thick hollow quartz tubes sealed with 10 to 15 mm thick cylindrical ends. The bars have hollow core but monolithic ends. Quartz, as the material for the bars, was selected due to its low thermal expansion coefficient. On the other hand, relatively large pressure coefficient and modulus of elasticity have been found. Repeated measurements are necessary since the lengths of quartz gauges change slightly over time. Slow lengthening of most bars has been observed. The present principal normal of the quartz gauge system is the bar no. 29. Regular absolute calibration with white and laser light gauge block interferometer of this bar brings scale to relative comparisons (Fig. 12) with other quartz meters. 67 CTU, Aalto, 2012 4. Calibration at the Nummela baseline Fig. 12: Quartz gauges (left) and quartz gauge comparator (right) at Tuorla Observatory With the present constellation of observations pillars, the only quartz gauge that can be used in the Väisälä interference comparator at the Nummela Standard Baseline is the exceptionally long quartz gauge no. VIII. For example, a 100 μm shorter bar would produce an 86.4 mm shorter baseline, demanding modified positions of observation pillars. The length of quartz gauge no. VIII is always determined before and after interference measurements at Nummela (Fig. 13). Several corrections, especially from temperature, have to be applied to achieve the absolute length under standard conditions. The final length may be the result of latest comparisons as well as the result of calculations based on the long time series of observations. Usually, the final length is the average of both. During each interference measurement at the Nummela Standard Baseline, the actual length of quartz gauge no. VIII is computed by correcting the standard length with temperature and atmospheric pressure corrections. 68 CTU, Aalto, 2012 4. Calibration at the Nummela baseline Fig. 13: Comparisons of the length of quartz gauge no. VIII at Tuorla Observatory Note: The black spot at 2000 signifies the absolute calibration of this particular gauge at MIKES. Subsection 4.1.3 uses bibliography: [8], [32]. The source of used figures: [8]. 4.1.4 Interference measurements The Nummela Standard Baseline is calibrated every few years through interference measurements with the Väisälä interference comparator. The FGI is currently the only institute, which carries out these high-precision measurements, latest in 2005 and 2007. Next observation is scheduled to 2013. The measurements are based on multiplication of length of a 1-m-long quartz gauge. A longer length is always a multiple of a shorter length. At the Nummela Standard Baseline, 864 m length is realized by using several multiplications: 2 x 2 x 3 x 3 x 4 x 6 x 1 m = 864 m. The method is basically simple, but extremely laborious to put into practice. Installation of the Väisälä interference comparator at the Nummela Standard Baseline takes about two weeks. The main parts of the Väisälä interference comparator (Fig. 14, Fig. 15, Fig. 16), mostly iron and glass, must be measured and fixed at proper locations with ±1 mm 3D-accuracy. The rest is controlled with the numerous adjusting screws around the mirrors in the comparator. A quartz meter (currently the no. VIII) brings the scale to the system. White light from a pointlike source is used. The beam is made parallel with a collimator lens and divided into two beams. One part of the light travels between the front mirror and the middle mirror, the other part travels to and from the back mirror (Fig. 14). The distance between the front and back mirrors is an integer multiple n of the distance between the front and middle mirrors. The light beam travels n times between the first two mirrors and once to and from the back mirror. The mirrors are adjusted in such a way that the two beams, travelling different paths, but equal 69 CTU, Aalto, 2012 4. Calibration at the Nummela baseline distances, meet at the focal plane of the observing telescope. The light source and the telescope include numerous fine-mechanical and optical components to control the light beams. The final adjustment of the incoming beams with adequate accuracy is made with the screen and the compensator glasses by delaying one of the two beams in front of the telescope. Fig. 14: The principle of the Väisälä interference comparator (interference 0-6-24) Fig. 15: Instruments of the Väisälä interference comparator at the pillars 0 and 1 70 CTU, Aalto, 2012 4. Calibration at the Nummela baseline Fig. 16: The mirror equipment of the Väisälä interference comparator Interference observations require extremely stable temperature conditions for length of hundred meters and longer. Otherwise it is not possible to control the course of reflecting beams and to adjust the mirrors and compensators with the required 0.001 mm accuracy to find interference fringes. For a one successful set of measurements, small (≤ 1° C) temperature differences are needed not only along the baseline but also during a seven hour observation period. In Nummela, during a two-three months autumnal measurement period, only a few cloudy nights are usually suitable for observation. In stable conditions, modeling the refraction is not a problem, since only the refraction difference between the divided two beams is needed. 31 thermometers are placed along the baseline to monitor these differences. Two observers and two assistants are needed almost seven days and nights a week during a measurement period. When the quartz gauge is placed between mirrors at 0 and 1 m, 0-1-6 interference may be observed and the length 0-6 could be determined. The 6-m-interference is then multiplied to longer length. The positions of mirrors are registered with a special transferring device relative to permanent transferring bars on every pillar and projected later between underground markers for further use. Projection measurements are performed before and after the interference measurement. This repetition reduces the total uncertainty, in which the projection measurements are a major factor, together with the uncertainty of the quartz meter length. Reverse projection correction are needed for EDM calibrations at observation pillars. In the year 2007 projections caused from 0,016 to 0,033 mm standard uncertainty, random errors in interference observations and transfer readings caused from 0,010 to 0,054 mm standard un- 71 CTU, Aalto, 2012 4. Calibration at the Nummela baseline certainty. The length of the quartz bar caused from 0,001 to 0,030 mm uncertainty in baseline lengths. Other smaller type B uncertainties were evaluated on the basis of experience with previous measurements during 60 years. Lengths of full time series of observations with total standard uncertainties are listed in (Table 2). They are lengths between underground benchmarks, reduced to the height level of underground marker at 0 m. Data from the first three shortest lengths during the years 19471975 are missing due to the absence of underground markers and observation pillars at these distances. Data from the 864-m-length from 1983 and 2005 are missing due to unfavorable weather conditions in which the measurements cannot be done. Latest measurements in 2005 and 2007 are in congruence with previous results and once again they proofed the stability of the baseline, great repeatability of observations and small uncertainties of measurement. Table 2: The Nummela baseline lengths during the years 1947-2007 Epoch 1947.7 1952.8 1955.4 1958.8 1961.8 1966.8 1968.8 1975.9 1977.8 1983.8 1984.8 1991.8 1996.9 2005.8 2007.8 The Nummela baseline lengths and standard uncertainties 0 - 24 0 - 72 0 - 216 0 - 432 0 - 864 [mm + 24 m] [mm + 72 m] [mm + 216 m] [mm + 432 m] [mm + 864 m] ------95.46 ± 0.04 122.78 ± 0.07 ------95.39 ± 0.05 122.47 ± 0.08 ------95.31 ± 0.05 122.41 ± 0.09 ------95.19 ± 0.04 122.25 ± 0.08 ------95.21 ± 0.04 122.33 ± 0.08 ------95.16 ± 0.04 122.31 ± 0.06 ------95.18 ± 0.04 122.37 ± 0.07 ------94.94 ± 0.04 122.33 ± 0.07 33.28 ± 0.02 15.78 ± 0.02 54.31 ± 0.02 95.10 ± 0.05 122.70 ± 0.08 33.50 ± 0.02 15.16 ± 0.02 53.66 ± 0.04 95.03 ± 0.06 --33.29 ± 0.03 15.01 ± 0.03 53.58 ± 0.05 94.93 ± 0.06 122.40 ± 0.09 33.36 ± 0.04 14.88 ± 0.04 53.24 ± 0.06 95.02 ± 0.05 122.32 ± 0.08 33.41 ± 0.03 14.87 ± 0.04 53.21 ± 0.04 95.23 ± 0.04 122.75 ± 0.07 33.23 ± 0.04 14.98 ± 0.04 53.20 ± 0.04 95.36 ± 0.05 --33.22 ± 0.03 14.95 ± 0.02 53.13 ± 0.03 95.28 ± 0.04 122.86 ± 0.07 Subsection 4.1.4 uses bibliography: [8], [29], [31]. The source of used figures: [8]. 4.1.5 Projection measurements In projection measurements, the temporary locations of the mirrors on observation pillars are projected onto the line between underground markers. Projection measurements are theodo- 72 CTU, Aalto, 2012 4. Calibration at the Nummela baseline lite-based high-precision measurements which are needed before and after, and usually also during the long-lasting interference measurement period. Reverse projections are necessary for EDM calibrations at the Nummela Standard Baseline. The lengths preserved between the underground markers are restored to lengths between forced-centering plates on observation pillars with repeated projection measurements. Usual frequency is three or four times a year due to measureable pillar movements during seasons. Projection measurements are based on precise horizontal angle measurements. A theodolite is adjusted on an observation pillar, pointings are made and angles are read to distant targets on one or two other observation pillars in the baseline direction and to a plumbing rod that is adjusted above the corresponding underground marker perpendicular to the baseline direction. For one projection, four sets of horizontal angles are measured in two theodolite face positions. The distance between the observation pillar and the underground marker is measured with a calibrated steel tape. Due to optimal geometry, one millimeter uncertainty of the length is easily obtained and sufficiently accurate. The projection corrections are calculated with trigonometric formulas. Even if there is a systematic difference in projections obtained from two different theodolites, this variation is not corrected since it would not be valid for other instruments. The result is calculated as an average of both. Empirically, based on long experience, the standard uncertainty of projection corrections was estimated to be ±0.07 mm. Fig. 17: A plumbing rod above an underground marker (left), a set of adaptor bars (right) Subsection 4.1.5 uses bibliography: [8], [30]. The source of used figures: [8]. 73 CTU, Aalto, 2012 4. Calibration at the Nummela baseline 4.1.6 Scale transfers to other baselines The Väisälä-type Nummela Standard Baseline of the FGI is the state-of-the-art geodetic baseline in the world. The FGI participated in calibrations of baselines using the Väisälä interference comparator at several places all around the world. Considering shipping problems, the amount of time and number of specialists necessary for measurements, this cannot be done very often and regular measurements at each baseline is not possible. Therefore a simpler method was developed by the FGI. Current most accurate EDM instruments are used for scale transfers from the Nummela Standard Baseline to other baselines. Mostly often, the Kern Mekometer ME5000 of the FGI is used. It is calibrated at the Nummela Standard Baseline several times before and after the scale transfer to other baseline. Whereas a baseline, calibrated with the Väisälä interference comparator, has the standard uncertainty about 0.1 mm/km, a baseline, calibrated with Kern Mekometer ME5000, has the standard uncertainty about 0.3 mm/km. During the last 15 years the scale of the Nummela Standard Baseline has been transferred to nearly 20 baselines and test fields in more than 10 countries all around the world. Subsection 4.1.6 uses bibliography: [29], [31]. 4.2 Instruments and equipment 4.2.1 The Leica TCA2003 The first calibrated EDM instrument is an electronic distance meter integrated in Leica TCA2003 total station (Fig. 18). The instrument was calibrated together with a reflector Wild Leitz GPH1P. The instrument is owned by Aalto University, School of Engineering, Department of surveying. Lending was arranged by prof. Martin Vermeer. Leica TCA2003 is the high-performance total station intended to be used for precision measurement. This specific instrument was manufactured in the year 2000. It was last calibrated on the 6th March 2001 by the Institute of Geodesy (HUT). Although the model TCA2003 was produced since 1997 and so it is not the very modern instrument, it has become well known because of its exceptional precision and accuracy and it has been used for many calibrations of EDM baselines. Still nowadays it is one of the most precise electronic distance meters. 74 CTU, Aalto, 2012 4. Calibration at the Nummela baseline The manufacturer dedicates the accuracy of 1 mm + 1 ppm. The heard of the electronic distance meter inside Leica TCA2003 is a stable quartz oscillator with a guaranteed drift less than 1 ppm. It uses the phase measurement principle and the source of light is an invisible coaxial infrared laser with a wavelength of 805 nm. Measurement of an individual distance in the standard mode takes about 3 seconds. The distance range is about 5 kilometers. The reference refractive index is 1.000281800 which corresponds to reference conditions (temperature 12 °C, pressure 760 Torr, relative humidity 60 %). Working temperature range is from °C to 50 °C under maximum relative humidity 95 % (non-condensing). Fig. 18: Leica TCA2003 + Wild Leitz GPH1P Table 3: Constants used for calculations – Leica TCA2003 Constants - Leica TCA2003 Quantity Value EDM carrier wavelength: 850 Reference temperature: 12 Reference atm. pressure: 1013.25 Reference relative humidity: 60 Reference refractive index: 1.00028180 Initial additive constant: 0.00 Initial scale correction: 0.00 EDM instrument height: 0.240 Reflector height: 0.240 Assmann psychrometer constant: 0.000662 Radius of the Earth: 6370000 Subsection 4.2.1 uses bibliography: [33]. 75 Unit nm °C hPa % mm mm m m m 20 CTU, Aalto, 2012 4. Calibration at the Nummela baseline 4.2.2 The Kern Mekometer ME5000 The second calibrated instrument is an electronic distance meter Kern Mekometer ME5000 (Fig. 19). The instrument was calibrated together with a supplied reflector Kern RMO5035. The instrument is owned by Aalto University, School of Engineering, Department of surveying. Lending was arranged by prof. Martin Vermeer. Kern Mekometer ME5000 is the precision electronic distance meter. It is the older instrument considering that the calibrated instrument was manufactured in the year 1994. But still today, Mekometer ME5000 is known as the most precise medium range distance meter in the world with accuracy of 0.2 mm + 0.2 ppm declared by the manufacturer. This type of instrument has become very valuable with time since it is no more produced and since no other type of instrument with equivalent precision and accuracy is available on the market. The calibrated instrument is the only instrument of its kind in Finland. It is widely used by the FGI as the length transfer standard between calibration baselines. The instrument is periodically calibrated at the Nummela Standard Baseline several times a year. Distance measurement of Mekometer ME5000 is based on a modified phase measuring principle. Rather than using fixed modulation frequencies and measuring phase differences, the modulation frequency is adjusted within a certain range until the transmitted and received signals are in phase. This is done at four frequencies, namely at both ends of the tuning range and twice in the middle of it. All measured frequency differences are used to calculate a displayed distance. Known frequencies are obtained from a frequency synthesizer. The source of light is a HeNe infrared laser with a wavelength of 632.8 nm. Measurement of an individual distance in the standard mode takes about 2 minutes. The distance range is from 20 meters to about 8 kilometers. The reference refractive index is 1.000284514844 which corresponds to reference conditions (temperature 15 °C, pressure 760 Torr, relative humidity 0 %, CO2 concentration 0.03 %). Working temperature range is from 76 10 °C to 50 °C. CTU, Aalto, 2012 4. Calibration at the Nummela baseline Fig. 19: Kern Mekometer ME5000 + Kern RMO5035 Table 4: Constants used for calculations – Kern Mekometer ME5000 Constants - Kern ME5000 Quantity Value EDM carrier wavelength: 632.8 Reference temperature: 15 Reference atm. pressure: 1013.25 Reference relative humidity: 0 Reference refractive index: 1.000284514844 Initial additive constant: 0.00 Initial scale correction: 0.00 EDM instrument height: 0.330 Reflector height: 0.330 Assmann psychrometer constant: 0.000662 Radius of the Earth: 6370000 Unit nm °C hPa % mm mm m m m Subsection 4.2.2 uses bibliography: [34]. 4.2.3 Other used instruments and equipment The EDM instruments are not the only devices used in the calibration process. The same attention should be given to instruments used for measuring atmospheric conditions. Last but not least, the employed reflectors should be explored. The first used reflector was “Wild Leitz GPH1P” (Fig. 20) owned by Aalto University, School of Engineering, Department of Surveying. No serial number of the reflector was found. Unique identification should be established by an owner if several same type reflectors 77 CTU, Aalto, 2012 4. Calibration at the Nummela baseline are used in a company. There is a stick with a sign “TKK/M-OS” on used prism. It is a robust, high precision manufactured prism in a metal holder. Metal holders usually proof better durability than plastic ones. The eccentricity, which means the difference between the optical and the mechanical centers of the reflector, is presented by the manufacturer as 0.0 mm. The reflector was placed into a standard geodetic tribach manufactured by Wild. Fig. 20: The reflector “Wild Leitz GPH1P” The second used reflector was manufactured by Kern and denoted as “Kern RMO5035” (Fig. 21). It is owned by Aalto University, Shool of Enfineering, Department of Surveying. The serial number of the prism is 374414. There is a stick with a sign “HUT/GEODESY M023” on the metal holder. The reflector is specially designed to be used with Kern Mekometer ME5000. The target for optical pointing is below the prism. The height difference between prism and optical target reflects the height difference between the laser line and the line of sight of Kern Mekometer ME5000. The difference between the optical and mechanical centers of the reflector is presented by the manufacturer as 0.0 mm. The reflector was placed into a standard geodetic tribach manufactured by Leica. 78 CTU, Aalto, 2012 4. Calibration at the Nummela baseline Fig. 21: The reflector “Kern RMO5035” Two Assmann-type psychrometers “Thermometers Thies Clima“ (Fig. 22) were used to meausere dry and wet temperatures. Instruments are owned by the FGI and they are standardly used in calibrations. Destiled water is used to moisten the wet bulb. The smallest segment of the scale is 0.2 °C but readings can be easily performed with resolution of 0.1 °C. The temperature measuring range is from 35 °C to 40 °C. No corrections for temperatures were added since previous calibration of psychrometers produced corrections less than 0.1 °C with standard uncertainty 0.08 °C. Standard uncertainty of the measurement of temperatures with two psychrometers is estimated by the FGI as 0.11 °C. Fig. 22: Assmann-type psychrometer “Thermometer Thies Clima” 79 CTU, Aalto, 2012 4. Calibration at the Nummela baseline Two aneroid barometers „Thomen altimeters“ (Fig. 23) were used to observe air pressure. Instruments are owned by the FGI and they are standardly used in calibrations. The smallest segment of the scale is 1 hPa but finer resolution can be obtained by estimating segments of 0.1 hPa. The aneroids are periodically compared with a mercury barometer of the FGI and corrections are determined. A possible drift is monitored for a long period of time. Standard uncertainty of calibration of barometers is 0.1 hPa. Standard uncertainty of air pressure observations with two barometers according to the FGI is 0.2 hPa. Fig. 23: The aneroid barometers "Thomen altimeters" Relative humidity was determined using digital hand-held humidity and temperature meter “Vaisala HM 34“ (Fig. 24). The device was borrowed from Aalto University, School of Engineering, Departement of Surveying. Measurement range is from 0 % to 100 % relative humidity. Displayed resolution is 0.1 %. Manufacturer indicated value of accuracy is between 0 % and 90 % relative humidity and 2% 3 % between 90 % and 100 % relative humidity. For proper results, calibration of the instrument is required. Unfortunately no information about previous calibrations were obtained because most likely there were non calibrations of the device. Since this information is not available, the real accuracy of the instruments remains unknown. 80 CTU, Aalto, 2012 4. Calibration at the Nummela baseline Fig. 24: The relative humidity meter “Vaisala HM 34” 4.3 Measurement 4.3.1 Measurement information calibration baseline: Nummela Standard Baseline, Finland calibrated instruments: a) Leica TCA2003, S.No. 438743 + reflector Wild Leitz GPH1P, S.No. Unknown b) Kern Mekometer ME5000, S.No. 357094 + reflector Kern RMO5035, S.No. 374414 dates of measurement: weather: 2011-10-06 - Leica TCA2003 2011-10-07 - Leica TCA2003 2011-11-24 - Kern Mekometer ME5000 2011-11-25 - Kern Mekometer ME5000 2011-11-28 - Kern Mekometer ME5000 2011-10-06 - cloudy, rainy, light wind 2011-10-07 - partly cloudy, moderate wind 2011-11-24 - cloudy, rainy, moderate wind 2011-11-25 - cloudy, drizzly, calm 2011-11-28 - cloudy then clear, windy 81 CTU, Aalto, 2012 4. Calibration at the Nummela baseline temperature observation: Thermometer Thies Clima, S.No. 1101459 Thermometer Thies Clima, S.No. 1101460 pressure observation: Thomen altimetr, S.No. 126533 Thomen altimetr, S.No. 164610 humidity observation: Vaisala HM 34, S.No. 312338 measurer: Bc. Filip Dvořáček helping surveyors: Lic. Sc. Jorma Jokela Bc. Petra Stolbenková Panu Salo Table 5: Overview of measurements Overview of measurements Date of Calibrated measurement instrument 2011-10-06 2011-10-07 2011-11-24 2011-11-25 2011-11-28 Leica TCA2003 Kern ME5000 Calibration status Measured pillars Completed 1st 0, 24, 72, 216, 432, 864 nd 0, 24, 72, 216, 432, 864 Completed 2 Incomplete 1st st Completed 1 0, 24, 72, 216 nd Incomplete 2 432, 864 Completed 2nd 0, 24, 72 216, 432, 864 Table 6: Ranges of atmospheric conditions during calibrations Ranges of atmospheric conditions during calibrations Temperature [°C] Pressure [hPa] Rel. humidity [%] Calibrated Calibration instrument Min Max Min Max Min Max Leica TCA2003 Kern ME5000 1st 12.5 13.2 976.9 979.2 97 99 2nd 8.6 11.8 974.2 976.2 58 85 st 1 5.6 7.4 994.3 999.7 82 99 2nd 1.5 8.2 975.9 993.0 73 98 4.3.2 Measurement procedure The FGI measurement process was adopted in performed calibrations. It meets all requirements and principles for achieving the best possible results of calibrations in field conditions under reasonable amount of time. The measurement process was demonstrated by Lic. Sc. Jorma Jokela, the responsible person for length metrology of the FGI. When the FGI performs 82 CTU, Aalto, 2012 4. Calibration at the Nummela baseline calibrations for private subjects, similar measurement process is used. Observed data were recorded to small notebooks (Appendix 1, Appendix 2), no prearranged forms were used. Fig. 25: Calibrating the Leica TCA2003 + the Wild Leitz GPH1P Fig. 26: Calibrating the Kern Mekometer ME5000 + the Kern RMO5035 83 CTU, Aalto, 2012 4. Calibration at the Nummela baseline Distances between all combinations of two pillars were observed. It means 5 different distances from 6 different stations were measured. It is 30 distances together. The standard order of measurements was as shown in (Table 7). Exceptions were possible if there were reasons for them. Table 7: Order of measured distances EDM station order Reflector station order 0 24 72 216 432 864 24 864 432 216 72 0 72 0 24 216 432 864 216 864 432 72 24 0 432 0 24 72 216 864 864 432 216 72 24 0 The instrument and the reflector were centered on pillars by screwing tribrachs to Kern force-centering plates and they were leveled afterwards. The reflector was directed to the EDM instrument using mechanical collimator. Every specific distance was measured 5 times (Leica TCA2003) resp. 2 times (Kern Mekometer ME5000). Kern Mekometer ME5000 measures one distance about 2 minutes and the result itself is the mean of several partial results, therefore 2 times measurement is sufficient in most cases. New pointing to the target was carried out before each measurement to make measurements more independent and eliminate systematic error caused by wrong pointing. Pointing was done optically (Leica TCA2003) resp. electronically (Kern Mekometer ME5000). In this case, electronic pointing means manual adjusting of the laser-line to find the maximum reflection and the maximal strength of a returned signal. Displayed values were recorder with a resolution of 0.1 mm. Variations in measured distances were monitored, but no values were unused. When there was an obvious trend in 5 results, some more measurements were added to analyze what is happening. A big attention was paid to determining ambient atmospheric conditions. Two calibrated Assmann-type psychrometers were used to monitor dry and wet temperatures at both endpoints of measured distances. Fans of psychrometers were turned on immediately when stations were changed to provide satisfactory flow of air around the wet bulb. Psychrometers were placed in EDM instrument and reflector heights, horizontally by a maximum of a couple of meters from the instrument. Psychrometers were kept out of reach of direct sunlight. Dry and wet temperatures were read after the 1st and after the 4th measurement of a distance (Leica TCA2003) resp. during the 1st and during the 2nd measurement of a distance (Kern Mekometer 84 CTU, Aalto, 2012 4. Calibration at the Nummela baseline ME5000). By multiple temperature determinations, readings error could be eliminated and changes of temperatures in time could be detected. Walky-talkies were used to synchronize readings of temperatures at both endpoints. Readings were performed with a resolution of 0.1 °C. Air pressure was measured at the EDM instrument station only. Pressure variation along the baseline due to the height differences or weather changes was neglected, since there is only 4 meters maximum difference in height between the pillars. Maximal difference in pressure is therefore very small, about 0.5 hPa. In addition, this difference will be removed in evaluation process because all distances were measured in both directions. To measure atmospheric pressure, two mechanical aneroid barometers were used to eliminate errors and improve results. Readings of both barometers were performed after the 5th measurement of a distance (Leica TCA2003) resp. between the 1st and the 2nd measurement of a distance (Kern Mekometer ME5000). Before readings, pointers of barometers were arranged to zero. Readings were performed with a resolution of 0.1 hPa. The barometers were compared with the mercury barometer of the FGI before and after the calibration of the EDM instrument. Means of these two comparisons were used to obtain final corrections. Partial water vapor pressure must be determined for computation of the first velocity correction. It can be evaluated from measurements of dry and wet temperatures and air pressure which is the way how it is standardly done by the FGI. But because there was available also a digital instrument for measuring relative humidity, borrowed from Aalto University, it was used for comparison (Leica TCA2003 only). Measurements were done at EDM instrument stations. Reading resolution was 0.1 %. 4.4 Evaluation process 4.4.1 Software For computations, the combination of two mathematically orientated computer programs was used. Microsoft Excel 2010 (version 14.0.6112.5000) and Mathworks Matlab R2011b (version 7.13.0.564) were the main software tools used to perform calculations. Microsoft Excel was picked for its well-arranged and easily readable spreadsheet data structure. Observed data and pre-processed data, recorded in an Excel file with a table structure, are easily readable, understandable and accessible for everyone who has a computer with installed Microsoft Ex- 85 CTU, Aalto, 2012 4. Calibration at the Nummela baseline cel software. Mathworks Matlab was chosen for its advanced and scientific functions enabling to create a specific piece of program code or a script to perform requested operations. As a source of data for the script, the previously created Excel file was used. Graphical results were also generated from Matlab software. Advantageous connection of both of these software enabled that numerical results could be automatically written into the Excel file after all computations in Matlab software were finished. 4.4.2 Data pre-processing in Excel All observed data were originally recorded in an analogue written form in notebooks. They were retyped into Excel files. Each calibration has its own Excel file with several different sheets (Appendix 3). Files are named according to a date or dates of measurement. The first sheet “info” contains information about calibration (calibrated EDM instrument, used reflector, calibration baseline, date of measurement, weather conditions) and necessary constants needed for further computations (EDM carrier wavelength, reference conditions, reference refractive index, heights of instruments, initial instrumental corrections, psychrometer constant, radius of the Earth). The second sheet “observation” gathers all observed data and provides initial preprocessing. The first table shows all measured distances and computes arithmetic means of distances, differences (distance mean) and type A uncertainties of means according to the EA 4/02 [19] and the GUM [20]. The second table processes the temperature observations. Arithmetic means of two observations of dry and wet temperatures at both endpoints of distances are evaluated and consequently average temperatures along the lines are computed as arithmetic means of temperatures obtained at both endpoints. The third table records observations of air pressures, introduces corrections of used aneroid barometers and computes final pressures as arithmetic means of data obtained from two barometers. The third sheet “baseline” shows all baseline data (Appendix 6) which are used for further computations (pillar heights, projection corrections, true distances). These data are not obtained from measurements with EDM instrument, but they are known from previous calibration of the baseline. These data should be as up-to-date as possible to reach the best possible results of calibration. The fourth sheet “p.w.v.p.” computes and compares partial water vapor pressures and relative humidities. In the first table, source data are processed. When there are measurements of 86 CTU, Aalto, 2012 4. Calibration at the Nummela baseline relative humidity from relative humidity meter, the second table computes partial water vapor pressures from relative humidity, dry temperatures and air pressures. All calculations meet equations stated in subsection 2.6.3. The third table compares both calculated partial water vapor pressures and shows how differences could affect the distance. All the tables were used to compare two methods of obtaining the partial water vapor pressure. Since the differences were significant and the used relative humidity meter has no calibration certificate, measurements of relative humidity were not used in further computations. In fact, the Matlab script computes partial water vapor pressures itself, so tables in this sheet have only informative character. The fifth sheet “temperature” compares differences between average temperatures at both endpoints. Differences are computed as temperature at the EDM instrument minus temperature at the reflector station. Differences are intended to be used for analysis of uncertainties of measurement. Unfortunately, two psychromoters were not always placed in the same way. It means sometimes their positions were interchanged due to some inattention of people operating them. This makes no affection to the results of calibrations but it makes the analysis of uncertainties more complicated. Small systematic error, which is present in every measurement between both psychrometers, has now sometimes an opposite mathematical sign. Since the systematic error is very small and the interchanged positions were recorded, it makes the analysis possible. The sixth sheet “processed” gathers all previously computed data which are handled to Matlab for further computations. Data in this table are mean distances, dry and wet temperatures and air pressures. The seventh sheet “results” shows numerical results computed in Matlab. There is the additive constant, the scale correction and the root-mean-square deviation calculated separately and using simple linear regression. The root-mean-square deviation of the cubic regression is also present. Coefficients of cubic regressions are not recorded since they are not very interesting for practical purposes. The third table shows some partial results of computations from Matlab as velocity corrections, geometrical corrections, measured minus true distances and residuals. The eighth sheet “uncertainties” contains a table created according to the EA 4/02 [19] describing all identified uncertainties in the measurement process. Creation of this uncertainty budget of measurement is described in subsection 4.4.4. 87 CTU, Aalto, 2012 4. Calibration at the Nummela baseline 4.4.4 Data processing in Matlab The core of the script (Appendix 7), programmed in Mathworks Matlab R2011b, is the file “main”. It is the only runnable file, the other files are functions which are automatically called by the main program. The function “ac” computes the additive constant, the function “sc” computes the scale correction, the function “reg” computes simple linear regression and cubic regression, the function “graph” plots all graphical outputs. Every piece of program code has been written in a way to be valid for all calibrations on the Nummela Standard Baseline. The only thing, which has to be changed before running the script, is the name of the Excel data source file. After few corrections, the program code may be also usable to be applied for evaluations of measurements performed on other calibration baselines with different measurement procedures. The file “main” is divided into cells according to logical reasons. In the first cell, there are information about purpose and release of the script. Information about version of Matlab, in which the script was created, is also included. The second cell identifies the Excel data source file, from which all input data will be extracted. This name should be changed according to a calibration set which is desired to be evaluated. The third cell imports the data from the chosen Excel file into Matlab memory. Data from sheets “info”, “baseline” and “processed” are imported. The cells from fourth to ninth performed requested calculations. The last tenth cell writes numerical results back into the Excel source file in the sheet “results”, create graphs by calling the function “graph” and displays some information into the Matlab active terminal window. When this appears in the Matlab, the program has performed all requested operations and has been successfully terminated. The fourth cell deals with the first velocity correction. Partial water vapor pressures are computed from psychrometer and barometer observations according to subsection 2.6.3. First velocity corrections are evaluated according to Ciddor and Hill equations, described in subsection 2.6.4. If there is a reference refractive index given in the Excel source file (different from zero), priority is given to this value and computed reference refractive index from referent atmospheric conditions remains unused. If the initial reference refractive index is not known from Excel (zero value), computed value is used for evaluating first velocity corrections. Corrected distances are computed by applying these corrections to measured distances. The fifth cell introduces the vertical geometrical correction. Station and target pillar heights, EDM instrument and reflector heights above pillars are taken into account to calcu- 88 CTU, Aalto, 2012 4. Calibration at the Nummela baseline late heights above the reference point. Height reference point of the Nummela Standard Baseline is placed at the underground marker of the pillar at 0 m. Corrections are evaluated according to equation (1.3). Corrected distances, which are horizontal distances in reference level, are computed by applying these corrections to distances obtained in previous cell. The sixth cell calculates the additive constant using the least squares adjustment. Baseline true distances are not used. If there is an initial additive constant given in the Excel file (different from zero), the value is applied to all distances before calculations. Function “ac” is called to evaluate the additive constant and its standard deviation according to subsection 3.4.2. The additive constant is applied to all distances obtained in the previous cell. The second computation of the additive constant, using corrected distances, is performed for control reasons. The testing criterion 0.001 mm is used. If the second computed additive constant exceeds the criterion, an error message occurs in the Matlab terminal and the program is aborted. The seventh cell finds the scale correction. If there is an initial scale correction given in the Excel file (different from zero), the value is applied to all distances before calculations. Projection corrections are added to all distances (obtained in the previous cell) and differences between corrected measured distances and true baseline distances are computed. The scale correction is evaluated using modified simple linear regression. The modification consists in omission of the intercept term. Function “sc” is called to evaluate the scale correction and its standard deviation according to subsection 3.4.2. Residuals are computed. The scale correction is applied to all distances (obtained in previous cell and modified by projection corrections). The second computation of the scale correction, using corrected distances, is performed for control reasons. The testing criterion 0.001 mm is used. If the second computed scale correction exceeds the criterion, an error message occurs in the Matlab terminal and the program is aborted. The eighth cell figures out the root-mean-square deviation from residuals obtained in the previous cell. The ninth cell performs regression analysis. Function “reg” is called to evaluate coefficients of the regress line according to subsection 3.4.1. The coefficients may stand for the additive constant and the scale correction. Standard deviations of the coefficients and residuals are calculated. In addition, cubic regression model is employed to obtain the rootmean-square deviation of the cubic curve. As noted above, the tenth cell writes the numerical results into the Excel file and creates graphs which are saved to folder “Graphs”. Five different graphs are plotted. They are titled “Additive constant analysis”, “Scale correction analy- 89 CTU, Aalto, 2012 4. Calibration at the Nummela baseline sis”, “Residuals analysis”, “Simple linear regression” and “Cubic regression”. The first three graphs are connected with the separate method and the last two graphs are connected with the combined methods of computation of instrumental corrections. 4.4.5 Uncertainties of measurement Evaluation of uncertainties of measurement is an essential and necessary part of every calibration. The analysis of uncertainties is processed according to the EA 4/02 [19] with respect to the GUM [20]. The uncertainty budget of measurement was created for each calibration and it is included in Excel files in the sheet “uncertainties”. The purpose of this analysis is to determine uncertainties of the additive constant and the scale correction. The purpose is not to determine the uncertainty of a measured distance. In that case, more uncertainties have to be taken into account. This task is left for a user of an instrument. The only standard uncertainty, contributing to the standard deviation associated with the additive constant, is the standard deviation obtained from the least squares adjustment. All other uncertainties (centering, leveling, measuring atmospheric conditions) are considered to be already included in the uncertainty from the adjustment. On the other hand, to obtain standard uncertainty associated with the scale correction, there are some additional quantities which have to be included in the uncertainty budget of measurement. All quantities, which were considered to take part in the combined standard uncertainty (standard uncertainty associated with the output estimate), are listed in (Table 8). 90 CTU, Aalto, 2012 4. Calibration at the Nummela baseline Table 8: Description of quantities contributing to the standard uncertainty Quantity Description Xi s p ac sc Ti Nummela scale Projection measurements EDM additive constant EDM scale correction Temperature instruments To Temperature observations pi Pressure instruments po Pressure observations ec P.w.v.p. calculations eo P.w.v.p. observations u Combined std. uncertainty Nearly all values of standard uncertainties were taken from the FGI and inspired by their long experience with calibrating EDM instruments at the Nummela Standard Baseline. The uncertainty of the scale of the Nummela Standard Baseline is expressed as 0.10 mm/km. This value is an estimate which comes from uncertainties of true baseline distances measured with the Väisälä interferometer. An instability of underground markers since last interference measurements is considered negligible. The standard uncertainty of projection measurement (two corrections for each distance) is set to be 0.07 mm. This value is non-distant dependent for distances below 864 meters. Therefore a value of 0.081 mm/km is used by the FGI. This value may seem sort of controversial because of mixing fixed and proportional standard uncertainty. But there is no other simple way how to employ non-distance dependent standard uncertainty in the uncertainty associated with the scale correction. Experience has shown that this simplification is possible. Instability of pillars since last projection measurements is considered negligible. Standard deviations of longitudinal effective temperatures were analyzed from differ- ences between point temperatures at both endpoints of distances. Previous experience was also used. To compute sensitive coefficients for temperature, air pressure and partial water vapor pressure, partial differentials of Ciddor and Hill equation (2.22) were derived. Mean atmospheric conditions were used to obtain numerical values with sufficient accuracy. 91 CTU, Aalto, 2012 4. Calibration at the Nummela baseline N L 273.15 N g p 11.27 e T 1013.25 T 2 T2 (4.1) N L 273.15 N g p 1013.25 T (4.2) N L 11.27 e T (4.3) The Ciddor and Hill closed formulae, adopted by the IAG in 1999, has some uncertainty itself. It is noted, that the closed equation deviates less than 0.25 ppm from the accurate formulae between 30 °C and 45 °C, at 1013.25 hPa and 100 % humidity. Under temperatures at about a middle of the interval, it should be even less. But since the same equation should be used in calibrations as well as in applications, the uncertainty of computation the first velocity correction is not usually included in evaluation of uncertainty associated with the scale correction. All used uncertainties of measurements are type B uncertainties. Because there are multiple observations of each distance, it offers to use also the type A evaluation of standard uncertainty. The first reason against it is the number of observations. Two observations in case of Kern Mekometer ME5000 and even five observations in case of Leica TCA2003 are not sufficient numbers of repetition for reliable estimate of the type A uncertainty. Even if there are thirty different distances for separate analysis, combining them is not the pure attitude to it. The main reason against using the type A evaluation of standard uncertainty of a multiple measured distance in field conditions is that atmospheric conditions are very unstable. Therefore it is not possible to differentiate the influence of changing conditions and the influence of repeatability of measurement with specified instrument. In addition, most of the difference between measurements with precision EDM instruments is considered to be caused by unstable atmospheric conditions rather than by repeatability of devices. The repeatability of measurement may only be tested under laboratory conditions to achieve satisfactory results. Subsection 4.4.5 uses bibliography: [30]. 92 CTU, Aalto, 2012 4. Calibration at the Nummela baseline 4.4.7 Combining results of calibrations All analysis presented above concerns results of calibrations separately. Analyses of separate calibrations are unavoidable to be computed because they give the preliminary estimate of all values and may be used for deeper analysis of results. But when there are multiple calibrations available for processing, it is necessary to deal with it and combine partial results into one final output. The Excel file “Results” contains summary of results of calibrations and performs calculations combining the results. In most cases, final instrumental corrections are computed as equally weighted average of all partial calibrations (Table 19). In special cases, when weather conditions vary a lot and there are large differences between standard deviations from adjustments, weighted average may be used. Standard deviations from adjustment are used as weights. When there is only one calibration of an instrument, standard deviation from adjustment is the only accuracy information available. When there are multiple calibrations, new accuracy information occurs. Standard deviations from adjustments are a good tool to evaluate weights of calibrations but using them to evaluate final standard deviation is not the proper way to do it. Standard deviations from adjustments reflect fitting of instrumental corrections only relatively and do not give the absolute information. Two results may have huge difference between each other but still they will both have small standard deviations from adjustments. Therefore the experimental standard deviation is computed from results of partial calibrations (Table 19). The more calibrations are available, the more reliable estimate of experimental standard deviation is computed. Only two calibrations do not always give satisfactory result, therefore the experimental standard deviations have to be corrected according to previous experience with specified instrument (Table 20). In this case, values of Leica TCA2003 were not corrected because they give reasonable estimates, but values of Kern Mekometer ME5000 were corrected according to experience of the FGI. New uncertainty budgets of measurement have to be processed (Table 21, Table 22). Principles remain the same, but standard deviations from (Table 20) are employed. Standard deviations of observations of meteorological quantities are set to be zero because they are considered to be already included in standard deviations of instrumental corrections. It is not possible to separate different influences in field conditions. In addition, one value describing accuracy of temperature observations during multiple calibrations would be a doubtful num- 93 CTU, Aalto, 2012 4. Calibration at the Nummela baseline ber. Final instrumental corrections and extended (2σ) uncertainties are presented in (Table 23). 4.5 Results of calibrations This section presents results and uncertainties of computations performed as described in previous section 4.4. The same tables may be found in relevant Excel files. Presented graphs are saved in folder “Graphs”. Only two most interesting graphs are shown here, the other two graphs are introduced in (Appendix 8, Appendix 9, Appendix 10, Appendix 11), one graph is available in digital form only. Final results and comparison of results with FGI computations are presented in the last two subsections 4.5.3 and 4.5.4. It should be noted that all graphs, comparisons and final results in this section deal with separate computations of instrumental corrections. Results of computations of combined methods serve only for comparisons with separate computations. Please note, that not all decimal places of values are necessarily relevant to obtained accuracy. 4.5.1 The Leica TCA2003 Table 9: Results of computations – 2011-10-06, Leica TCA2003 Results of computations - Nummela, 2011-10-06, Leica TCA2003 (S.No. 438743) Computation Additive constant [mm] Scale correction [mm/km] RMS dev. method Value Std. dev. Value Std. dev. [mm] Separately 0.313 0.078 2.033 0.101 0.249 Simple lin. regress. 0.346 0.079 1.977 0.168 0.248 Cubic regression 0.217 Table 10: Results of computations – 2011-10-07, Leica TCA2003 Results of computations - Nummela, 2011-10-07, Leica TCA2003 (S.No. 438743) Computation Additive constant [mm] Scale correction [mm/km] RMS dev. method Value Std. dev. Value Std. dev. [mm] Separately 0.231 0.091 1.347 0.115 0.284 Simple lin. regress. 0.304 0.089 1.222 0.190 0.281 Cubic regression 0.203 94 CTU, Aalto, 2012 4. Calibration at the Nummela baseline Fig. 27: Graphs – 2011-10-06, Leica TCA2003 95 CTU, Aalto, 2012 4. Calibration at the Nummela baseline Fig. 28: Graphs – 2011-10-07, Leica TCA2003 96 CTU, Aalto, 2012 4. Calibration at the Nummela baseline Table 11: Uncertainty budget of measurement – 2011-10-06, Leica TCA2003 Uncertainty budget of measurement - 2011-10-06, Leica TCA2003 (S.No. 438743) Unc. contrubution u i (y ) Std. Sensitivity Quantity Unit Estimate x i Additive Scale uncert. coefficient constant correction Xi u (x i ) ci [mm] [mm/km] From To Unit s mm/km 0.10 1 ×L 0.100 p mm -1.627 1.627 0.07 1.157 0.081 0.313 ac mm 0.078 1 0.078 2.033 sc mm/km 0.101 1 ×L 0.101 -1 Ti K 0.11 0.947 × L [K ] 0.104 To K 285.7 286.3 pi hPa - po hPa 976.9 979.2 ec hPa 14.2 eo hPa 15.0 14.2 15.0 0.08 0.947 × L [K-1] 0.1 0.278 × L [hPa-1] -1 0.2 0.278 × L [hPa ] 0.1 0.039 × L [hPa-1] -1 0.4 0.039 × L [hPa ] u - 0.076 - 0.028 - 0.056 - 0.003 - 0.016 0.078 0.218 Table 12: Uncertainty budget of measurement – 2011-10-07, Leica TCA2003 Uncertainty budget of measurement - 2011-10-07, Leica TCA2003 (S.No. 438743) Unc. contrubution u i (y ) Std. Sensitivity Quantity Unit Estimate x i Additive Scale uncert. coefficient constant correction Xi u (x i ) ci [mm] [mm/km] From To Unit s mm/km 0.10 1 ×L 0.100 p mm -1.627 1.627 0.07 1.157 0.081 0.231 ac mm 0.091 1 0.091 1.347 sc mm/km 0.115 1 ×L 0.115 -1 Ti K 0.11 0.963 × L [K ] 0.106 To K 281.8 284.9 pi hPa - po hPa ec hPa eo hPa 974.2 976.2 8.0 8.0 9.5 9.5 0.36 0.963 × L [K-1] 0.1 0.280 × L [hPa-1] -1 0.2 0.280 × L [hPa ] 0.0 0.040 × L [hPa-1] -1 0.4 0.040 × L [hPa ] u - 0.347 - 0.028 - 0.056 - 0.002 - 0.016 0.091 0.407 Measurements with the Leica TCA2003 were held under very different weather conditions. During the first calibration on the 6th October 2011, there was cloudy and rainy whole day. On the other hand, during the second calibration on the 7th October 2011, there was clear and partly cloudy. Moderate wind helped to mix differently heated air layers, but still much 97 CTU, Aalto, 2012 4. Calibration at the Nummela baseline bigger differences up to 1 mm were obtained in five consecutive measurements of distances. Differences in dry temperatures at both endpoints also reached much bigger values, more than 1 °C. It causes not only minor increase of computed standard uncertainties but also significant difference in computed instrumental correction, especially in the scale correction. It may seem as a problem, but in fact it can be an advantage. Diverse weather conditions and diverse calibration results involve more possibilities of use of the instrument in praxis. The average of the results may has larger associated uncertainty, but it gives a more complex and reliable estimate of the true instrumental correction. 4.5.2 The Kern Mekometer ME5000 Table 13: Results of computations – 2011-11-24 and 25, Kern ME5000 Results of computations - Nummela, 2011-11-24 and 25, Kern ME5000 (S.No. 357094) Computation Additive constant [mm] Scale correction [mm/km] RMS dev. method Value Std. dev. Value Std. dev. [mm] Separately 0.023 0.050 0.209 0.068 0.168 Simple lin. regress. 0.115 0.051 0.051 0.108 0.159 Cubic regression 0.156 Table 14: Results of computations – 2011-11-25 and 28, Kern ME5000 Results of computations - Nummela, 2011-11-25 and 28, Kern ME5000 (S.No. 357094) Computation Additive constant [mm] Scale correction [mm/km] RMS dev. method Value Std. dev. Value Std. dev. [mm] Separately 0.025 0.042 0.268 0.066 0.163 Simple lin. regress. 0.105 0.050 0.131 0.106 0.156 Cubic regression 0.156 98 CTU, Aalto, 2012 4. Calibration at the Nummela baseline Fig. 29: Graphs – 2011-11-24 and 25, Kern Mekometer ME5000 99 CTU, Aalto, 2012 4. Calibration at the Nummela baseline Fig. 30: Graphs – 2011-11-25 and 28, Kern Mekometer ME5000 100 CTU, Aalto, 2012 4. Calibration at the Nummela baseline Table 15: Uncertainty budget of measurement – 2011-11-24 and 25, Kern ME5000 Uncertainty budget of measurement - 2011-11-24 and 25, Kern ME5000 (S.No. 357094) Unc. contrubution u i (y ) Std. Sensitivity Quantity Unit Estimate x i Additive Scale uncert. coefficient constant correction Xi u (x i ) ci [mm] [mm/km] From To Unit s mm/km 0.10 1 ×L 0.100 p mm -1.627 1.627 0.07 1.157 0.081 0.023 ac mm 0.050 1 0.050 0.209 sc mm/km 0.068 1 ×L 0.068 -1 Ti K 0.11 1.031 × L [K ] 0.113 To K 278.7 280.5 pi hPa - po hPa ec hPa eo hPa 994.3 999.7 8.4 10.2 8.4 10.2 0.10 1.031 × L [K-1] 0.1 0.289 × L [hPa-1] -1 0.2 0.289 × L [hPa ] 0.0 0.040 × L [hPa-1] -1 0.4 0.040 × L [hPa ] u - 0.103 - 0.029 - 0.058 - 0.002 - 0.016 0.050 0.222 Table 16: Uncertainty budget of measurement – 2011-11-25 and 28, Kern ME5000 Uncertainty budget of measurement - 2011-11-25 and 28, Kern ME5000 (S.No. 357094) Unc. contrubution u i (y ) Std. Sensitivity Quantity Unit Estimate x i Additive Scale uncert. coefficient constant correction Xi u (x i ) ci [mm] [mm/km] From To Unit s mm/km 0.10 1 ×L 0.100 p mm -1.627 1.627 0.07 1.157 0.081 0.025 ac mm 0.042 1 0.042 0.268 sc mm/km 0.066 1 ×L 0.066 -1 Ti K 0.11 1.030 × L [K ] 0.113 To K 274.6 281.3 pi hPa - po hPa ec hPa eo hPa 975.9 993.0 5.0 5.0 10.7 10.7 0.17 1.030 × L [K-1] 0.1 0.291 × L [hPa-1] -1 0.2 0.291 × L [hPa ] 0.0 0.041 × L [hPa-1] -1 0.4 0.041 × L [hPa ] u - 0.175 - 0.029 - 0.058 - 0.002 - 0.016 0.042 0.263 Two calibrations of the Kern Mekometer ME5000 were held in three days because of more complicated operation with the instrument and short November days in Finland. During the first two days there was quite similar weather, cloudy, rainy and drizzly. The third day it was cloudy and then clear, dry temperatures were lower than two days before. According to 101 CTU, Aalto, 2012 4. Calibration at the Nummela baseline experience of the FGI, Kern Mekometer ME5000 is less sensitive to weather changes (especially sunlight) than Leica TCA2003. One reason is its long time of single measurement which enables to mediate small changes of atmospheric conditions. Differences in dry temperatures were up to 0.6 °C in all three days. It all causes similar standard deviations from adjustment. The additive constant was practically the same at both calibrations, the scale correction differs slightly. 4.5.3 Summary and final results Following table gives well-arrange view of the most important results which were already presented in previous subsections 4.5.1 and 4.5.2. Table 17: Summary of results of calibrations EDM Leica TCA2003 Kern ME5000 Summary of results of calibrations Add. const. [mm] Scale corr. [mm/km] Calib. Value Std. dev. Value Std. dev. st 0.313 0.078 2.033 0.101 1 nd 0.231 0.091 1.347 0.115 2 st 0.023 0.050 0.209 0.068 1 nd 0.025 0.042 0.268 0.066 2 Table 18: Summary of uncertainties according to EA 4/02 EDM Leica TCA2003 Kern ME5000 Summary of uncertainties (EA 4/02) Standard uncertainty Calib. Add. const. [mm] Scale corr. [mm/km] st 0.078 0.218 1 nd 0.091 0.407 2 st 0.050 0.222 1 nd 0.042 0.263 2 102 CTU, Aalto, 2012 4. Calibration at the Nummela baseline Following tables deals with final instrumental corrections and associated uncertainties of measurement which come into existence by combining partial calibrations according to subsection 4.4.5. Table 19: Final instrumental corrections and experimental std. deviations Final instrumental corrections and exp. std. deviations Add. const. [mm] Scale corr. [mm/km] EDM instrument Value Std. dev. Value Std. dev. Leica TCA2003 0.272 0.041 1.690 0.343 Kern ME5000 0.024 0.001 0.238 0.030 Table 20: Final instrumental corrections and modified standard deviations Final instrumental corrections and mod. standard deviations Add. const. [mm] Scale corr. [mm/km] EDM instrument Value Std. dev. Value Std. dev. Leica TCA2003 0.272 0.041 1.690 0.343 Kern ME5000 0.024 0.020 0.238 0.080 Table 21: Uncertainty budget of measurement – Leica TCA2003 Uncertainty budget of measurement - Leica TCA2003 (S.No. 438743) Unc. contrubution u i (y ) Std. Sensitivity Quantity Unit Estimate x i Additive Scale uncert. coefficient constant correction Xi u (x i ) ci [mm] [mm/km] From To Unit s mm/km 0.10 1 ×L 0.100 p mm -1.627 1.627 0.07 1.157 0.081 0.272 ac mm 0.041 1 0.041 1.690 sc mm/km 0.343 1 ×L 0.343 -1 Ti K 0.11 0.959 × L [K ] 0.106 To K 281.8 286.3 pi hPa - po hPa ec hPa eo hPa 974.2 979.2 8.0 8.0 15.0 15.0 0.00 0.959 × L [K-1] 0.1 0.280 × L [hPa-1] -1 0.0 0.280 × L [hPa ] 0.1 0.040 × L [hPa-1] -1 0.0 0.040 × L [hPa ] u 103 - 0.000 - 0.028 - 0.000 - 0.004 - 0.000 0.041 0.382 CTU, Aalto, 2012 4. Calibration at the Nummela baseline Table 22: Uncertainty budget of measurement – Kern ME5000 Uncertainty budget of measurement - Kern ME5000 (S.No. 357094) Unc. contrubution u i (y ) Std. Sensitivity Quantity Unit Estimate x i Additive Scale uncert. coefficient constant correction Xi u (x i ) ci [mm] [mm/km] From To Unit s mm/km 0.10 1 ×L 0.100 p mm -1.627 1.476 0.07 1.157 0.081 0.024 ac mm 0.020 1 0.020 0.238 sc mm/km 0.080 1 ×L 0.080 Ti K 0.11 1.034 × L [K-1] 0.114 To K 274.6 281.3 pi hPa - 0.00 1.034 × L [K-1] 0.1 0.291 × L [hPa-1] -1 po hPa ec hPa 5.0 10.7 0.0 0.291 × L [hPa ] 0.1 0.041 × L [hPa-1] eo hPa 5.0 10.7 0.0 0.041 × L [hPa-1] 975.9 999.7 u - 0.000 - 0.029 - 0.000 - 0.004 - 0.000 0.020 0.192 Table 23: Final instrumental corrections and extended uncertainties Final instrumental corrections and extended uncertainties Add. const. [mm] Scale corr. [mm/km] EDM instrument Value ± (2σ) Value ± (2σ) Leica TCA2003 0.272 0.083 1.690 0.764 Kern ME5000 0.024 0.040 0.238 0.383 4.5.4 Comparison with FGI results Lic. Sc. Jorma Jokela from the FGI has provided results of calibrations evaluated in the official FGI fortran-programmed script. Also partial results of calibration were available. Comparison of results is presented in (Table 24). From analysis of partial results was discovered, that the only difference between both calculations is in the computation of the first velocity correction. Ciddor and Hill solution was used in both cases. But whereas in this paper the first velocity correction was computed according to closed IAG formulas (subsection 2.6.4), the FGI computes the first velocity correction according to a piece of Australian fortran program code which employs precise Ciddor and Hill solution. Anyways the results remain very close to each other. 104 CTU, Aalto, 2012 4. Calibration at the Nummela baseline Table 24: Comparison with FGI results Comparison with FGI results Additive constant [mm] Scale correction [mm/km] EDM Calib. Computed FGI results Computed FGI results Value Std. dev. Value Std. dev. Value Std. dev. Value Std. dev. st 0.313 0.078 0.314 0.080 2.033 0.101 2.001 0.098 Leica 1 nd TCA2003 2 0.231 0.091 0.230 0.092 1.347 0.115 1.304 0.112 Kern ME5000 1st 0.023 0.050 0.022 0.051 0.209 0.068 0.189 0.066 2nd 0.025 0.042 0.024 0.042 0.268 0.066 0.260 0.064 The calibrated Kern Mekometer ME5000 is being used as a scale transfer instrument by the FGI. Therefore its instrumental corrections are continuously monitored in time. Lic. Sc. Jorma Jokela from the FGI has provided results of previous calibrations of the instrument. Five calibrations were performed during a period of 16.5.-15.6.2011. Computed instrumental corrections in this paper are compared with previous results of calibrations in (Table 25). Table 25: Comparison with previous calibrations of Kern ME5000 Kern ME5000 calibrations (S.No. 357094) Additive constant [mm] Scale correction [mm/km] 16.5.-15.6.2011 24.-28.11.2011 16.5.-15.6.2011 24.-28.11.2011 0.039 0.024 0.181 0.238 105 CTU, Aalto, 2012 5. Nummela and Koštice baselines 5. NUMMELA AND KOŠTICE BASELINES In this chapter, it is intended to compare two calibration baselines and calibration procedures. The Nummela Standard Baseline in Finland is confronted with the Czech state long distances measuring standard Koštice. Even if the Czech state long distances measuring standard Koštice is the official name of the baseline, further in the text it will be called the Koštice Baseline for short. Provided data here are more or less informative and they are not official since a part of them comes from consultations with Lic. Sc. Jorma Jokela and Ing. Jiří Lechner, CSc. In case of the Nummela Standard Baseline the data are up to date, but in case of the Koštice baseline they were mostly collected during processing [2] in 2009/2010. 5.1 The Koštice Baseline The baseline was constructed between years 1979 and 1980 near a village Koštice in Louny region (Fig. 31). In 2006 VÚGTK was determined to provide research and development at the baseline with the view of declaration of a new Czech state measuring standard. Interlaboratory comparison was carried out by the Universität der Bundeswehr München. On 26th February 2008 the Koštice Baseline was announced as the new Czech state long distances etalon. Fig. 31: Schematic location and design of the Koštice Baseline 106 CTU, Aalto, 2012 5. Nummela and Koštice baselines The Koštice Baseline consists of 12 concrete-steel pillars with forced centering which are placed in a line along a road Koštice – Libčeves (Fig. 31). Stabilizations of pillars reach into depth from 5 to 9 meters. 66 distances between 25 and 1450 meters are realized by the pillars (Fig. 32). A set of fixing screws complements the baseline (Fig. 33). A vertical axis of a unique fixing screw, placed in a cylinder hole of forced centering, creates a geodetic point in place of intersection with metal plate of a pillar (Fig. 34). Standard geodetic tribachs may be mounted on the fixing screws to hold EDM instruments and reflectors. Fig. 32: Instruments on observation pillars at the Koštice Baseline Fig. 33: The set of fixing screws (left) and the detail of a fixing screw (right) 107 CTU, Aalto, 2012 5. Nummela and Koštice baselines Fig. 34: The section of forced centering of the Koštice Baseline Several methods were used to determine true baseline distances, including measuring with invar tapes and observing parallactic angles. Distances were measured in all combinations with Leica TCA2003 which is compared with etalon in München and with laser interferometer Hewlett Packard 5519A owned by VÚGTK. Least-square adjustment with observations weighted according to an accuracy of Leica TCA2003 was used to compute true distances. Inter-laboratory comparisons were made by Universität der Bundeswehr München using Leica TDA5005 and Kern Mekometer ME5000. Combined standard uncertainty of the Koštice baseline is determined to be as equation (5.1). u Q 0,5 mm ;1,5 mm /1000 m where u … combined standard uncertainty Q … quadratic sum of all partial uncertainties (5.1) Section 5.1 uses bibliography: [2], [35], [36], [37]. 5.2 Comparison of baselines, measurements and evaluations Both baselines serve as geodetic baselines for calibrating electronic distance meters. Even if the purpose of them is the same, their location, design, structure and accuracy is completely different. Considering the Nummela Standard Baseline as the most accurate baseline in the world and the Koštice Baseline as a new etalon established recently in 2008, it should be realized that the comparison of those two baselines is not a criticism of the Koštice Baseline. It is 108 CTU, Aalto, 2012 5. Nummela and Koštice baselines just a simple confrontation with a point of view of a student who had a chance to perform calibrations at both baselines. Tables seem to be the most suitable way of comparing the baselines, measurement procedures and evaluation processes since all specifications have been already described in this paper and in [2]. Table 26: Comparison of the Koštice Baseline and the Nummela Standard Baseline Comparison of Koštice Baseline and Nummela Standard Baseline Comparing The Koštice Baseline The Nummela Standard Baseline Location Czech Republic, Koštice Finland, Nummela Administrator VÚGTK The FGI Responsible person Ing. Jiří Lechner, CSc. Lic. Sc. Jorma Jokela Established 2008 (1979) 1947 (1933) Placing Along a road, open area Forest Subsurface Solid rock Sandy ridge with glacial origin Orientation North-West North-East Sunshine protection Temporal - umbrellas Pernament - shelters Weather sensors NO NO Points 12 6 Design For EDM instruments For invar wires, Väisälä comparator Stabilization Concrete-steel pillars Undergr. markers + concrete pillars Forced centering Fixing screws Fixed Kern plates Distances 66 30 Min. distance 25 24 Max. distance 1450 864 Calibration Leica TCA2003 Väisälä interference comparator Traceable scale Through laser interferometer Through quartz gauge system Accuracy (1-σ) 0.5 mm + 1.5 mm/km 0.1 mm/km Projection measur. 0.07 mm Stability Previous stability problems Max. difference 0.6 mm in 60 years 109 CTU, Aalto, 2012 5. Nummela and Koštice baselines Table 27: Comparison of measurement procedures at Koštice and Nummela baselines Comparison of measurement procedures at Koštice and Nummela baselines Comparing The Koštice Baseline The Nummela Std. Baseline 30 30 Measured distances From first 3 pillars forward All combinations Horizontal distances Slope distances Observations of a distance 3 5 Time of one calibration Approx. 2 hours 5-6 hours Number of calibrations 1 Min. 2, usually 3 or more Reflectors More than one allowed Always one Sunshine protection Uncommon Always Weather report NO YES Tepmerature instruments Unknown Calibrated psychrometers At EDM instrument only At both endpoints Temperature measurement Twice per calibration Twice per distance Pressure instruments Unknown Calibrated aneroids At EDM instrument only At EDM instrument only Pressure measurements Twice per calibration Once per distance Rel. humidity instruments None Calibrated psychrometers Nowhere At both endpoints Rel. humidity measurement Never Twice per distance Table 28: Comparison of evaluation processes at Koštice and Nummela baselines Comparison of evaluation processes at Koštice and Nummela baselines Comparing The Koštice Baseline The Nummela Standard Baseline First velocity correction Instrument-determined Ciddor and Hill formulas Reference refractive index Instrument-considered From manufacturer or computed Geometrical correction Unknown YES Computation of corrections Combined Separately Additive constant Simple linear regression Least squares adjustement Scale correction Simple linear regression Modified simple lin. regression Final results Result of single calibration Mean of multiple calibrations Type A uncertainty Included Not included Experience-modified uncert. Possible Possible Final uncertainties Extended 2-σ (95%) Extended 2-σ (95%) Both baselines serve as the most accurate calibration standards in their countries and fulfill functions of national etalons. It is not fully objective to compare measuring procedures and evaluation processes with each other because of the different accuracy of the baselines. Less difficult and less time-consuming methods may be used in case of the less accurate baseline to achieve satisfactory results which are in congruence with baseline accuracy. Both baselines are continuously progressing for purpose of delivering the most reliable results. At the Nummela Standard Baseline, development in the field of electronic measurement of atmos- 110 CTU, Aalto, 2012 5. Nummela and Koštice baselines pheric conditions is taking a part. The new Väisälä automatic weather station AWS330 has been bought by the FGI to monitor conditions at the EDM instrument station. More weather stations will be probably bought after testing period. At the Koštice Baseline, measurements with newly purchased Leica AT401 absolute tracker are in preparations towards reducing total uncertainties of true distances. 5.3 Research and development This section focuses on the research and development in the field of electronic distance measurement presented by EURAMET in a document called “Towards New Absolute Long Distance Measurement Systems In Air” [38]. Nine laboratories from eight different countries, including the FGI, MIKES and CMI, are participating in a project called “Absolute long distance measurement in air”. The new development already concerns the Nummela Standard Baseline and it will probably concern the Koštice Baseline as well in the future. Not all scientific terms presented below are fully explained since it is not possible to give a complex description of the new techniques in such a space-saving way. The project has the ambition to improve the current state-of-the-art in the long range distance measurements reaching a relative accuracy of 10-7. That accuracy is a challenge at present time. The FGI is the only metrological institute in the world which is currently maintaining and developing the technique of optical interferometry with the similar accuracy. But the realisation of such measurement is very time-consuming and requires very stable atmospheric parameters. In this project, EURAMET is trying to develop new generation of instruments making the measurement easier and basically with a higher resolution. Challenge in the field of long distance measurement is precise knowledge of effective refractive index over a large range. To measure a local refractive index, improved absolute refractometer will be developed. The idea is to employ helium as a standard of the refractive index in a gas refractometer to be able to monitor distortion of the cavity at different pressures and decrease final uncertainty. Spectroscopic methods of measuring effective humidity and temperature along the beam pass will be explored. The same beam path can be used in both spectroscopy and length measurement allowing perfect spatial and temporal overlap of all observations. Even though the uncertainty of the temperature measurement will be modest compared to traditional locally measuring thermometers, even 1°C accuracy for average tem- 111 CTU, Aalto, 2012 5. Nummela and Koštice baselines perature in the beam path would be significant improvement to the existing methods in the outdoor environment. For well-known reasons, the classical optical interferometry is not appropriate for long range absolute distance measurements. Ambiguity about the integer part and uncontrolled environment causing air index fluctuations and mechanical vibrations are some of those. In response, researchers have developed multi-wavelength interferometric measurement based on a synthetic wavelength (spatial frequency is obtained from an interferometer injected by two different wavelengths). Using the synthetic wavelength, which is much longer than the optical wavelength, the integer part ambiguity and the sensitivity to air index fluctuations and vibrations are greatly reduced. By using different synthetic wavelength, the ambiguity can be removed and absolute distance measurement can be performed. Within this work-package, a femtosecond frequency comb laser will be applied as a tool for distance measurements. Two different techniques will be implemented. The first is using the phase locking property between pulses emitted by the ultrafast laser. This allows for interference between different pulses. Frequency comb enables direct traceability from the practical realization of the meter to the definition of the second. Current frequency standards such as atomic clocks operate in the microwave region of the spectrum, and the frequency comb brings the accuracy of such clocks into the optical part of the electromagnetic spectrum. For these measurements, the repetition rate and the carrier-envelope offset frequency of the comb laser are phase locked to a reference value provided by a time standard. The main task is to extend the measurement range from centimeters up to 100 meter and to identify the limits of this technique. Secondly, a femtosecond laser is applied as an advanced frequency modulator which allows using higher modulation frequencies. Methods of deriving the refractive index of air from measurements performed with the femtosecond laser will be also explored. Section 5.3 uses bibliography: [38], [39]. 112 CTU, Aalto, 2012 Conclusions CONLUSIONS The aim of the paper was to explore and describe problematic of field calibrations of electronic distance meters. Provided information can be useful for academic purposes as well as for users of instruments who would like to meet this topic. Since distance is a fundamental physical unit and electronic distance meters are the most often used instruments for measuring distances in geodesy, learning about accuracy of these instruments should be one of the most important matters to care about. The author of the paper has got an opportunity to calibrate instruments at the Nummela Standard Baseline in Finland which is considered to be the most accurate field calibration standard worldwide. Thanks belong to the Finnish Geodetic Institute and especially to Lic. Sc. Jorma Jokela. The chance to measure with Kern Mekometer ME5000, the unique instrument widely known for its exceptional accuracy, is also very valuable experience. In addition, performed calibrations were not meaningless even if official calibration certificates were not executed. The Leica TCA2003 was calibrated for the first time in many years and computed corrections may be used by Aalto University for academic purposes. The Kern Mekometer ME5000, the important scale transfer instrument of the Finnish Geodetic Institute, is periodically calibrated to monitor the drift of instrumental corrections. Performed calibration was noted in the time line of observations with this instrument at the Nummela Standard Baseline. Because of previous calibrations on the Koštice Baseline in Czech Republic realized by the author, there was an opportunity to compare baselines, equipment, measuring procedures and evaluation processes, even if the same EDM instruments were not used in both cases. Considering the long history, stability and accuracy of the Nummela Standard Baseline, the reputation of the Finnish Geodetic Institute and deep experiences of Lic. Sc. Jorma Jokela, pieces of knowledge from Finland could inspire the Research Institute of Geodesy, Topography and Cartography in the Czech Republic. The valuable contact with the Finnish Geodetic Institute will enable further co-operation, for example the participation during interference measurements at the Nummela Standard Baseline in 2013. Current state-of-the-art technology of calibration of electronic distance meters will face important changes in near future as the new development in this field will continue to progress. Absolute distance measurements by synthetic wavelength interferometry and by femto- 113 CTU, Aalto, 2012 Conclusions second technology are developing as well as spectroscopic methods for measuring temperature and humidity along the signal path. Research is being developed by a group of European organizations dealing with geodesy and metrology. Both Finland (FGI) and the Czech Republic (CMI) are participating in the research. Comparison of new methods with classical ones will be held in order to verify the usability and reliability of new technologies. The Nummela Standard Baseline will be used for these purposes. 114 CTU, Aalto, 2012 Bibliography BIBLIOGRAPHY [1] ČVUT. Metodický pokyn č. 1/2009. ČVUT. [Online] July 1, 2009. [Cited: October 19, 2011.] http://www.cvut.cz/informace-prozamestnance/legislativa/resolveuid/f89c51cca3ec466e5c5141b9496fc779. [2] Dvořáček, Filip. Kalibrace elektronických dálkoměrů na státním etalonu velkých délek Koštice. Prague : CTU, 2010. [3] Ratiborský, Jan. Geodézie 10. Prague : CTU, 2005. ISBN 80-01-03332-5. [4] Wikipedia contributors. Metrology. Wikipedia. [Online] 5046876, Wikipedia The Free Encyclopedia, November 3, 2011. [Cited: November 5, 2011.] http://en.wikipedia.org/w/index.php?title=Metrology&oldid=464285816. [5] —. Accuracy and precision. Wikipedia. [Online] Wikipedia - The Free Encyclopedia, September 15, 2011. [Cited: September 26, 2011.] http://en.wikipedia.org/w/index.php?title=Accuracy_and_precision&oldid=4507 08642. [6] —. Relative humidity. Wikipedia. [Online] Wikipedia - The Free Encyclopedia, September 28, 2011. [Cited: October 2, 2011.] http://en.wikipedia.org/w/index.php?title=Relative_humidity&oldid=452872374. [7] Vobořilová, Pavla and Skořepa, Zdeněk. Geodézie 1, 2 Návody na cvičení. Prague : CTU, 2005. ISBN 80-01-02869-0. [8] Jokela, Jorma and Häkli, Pasi. Interference Measurements of the Nummela Standard Baseline in 2005 and 2007. Finnish Geodetic Institute. [Online] 2010. [Cited: October 19, 2011.] http://www.fgi.fi/julkaisut/pdf/FGI_Publ_144.pdf. ISBN-13:978-951-711-283-3. [9] Tesař, Pavel. Redukce délek. 152EMEG Elektronické metody v geodézii. [Online] 2010. [Cited: únor 24, 2010.] ftp://athena.fsv.cvut.cz/EMEG/Redukce.pdf. [10] Rüeger, J. M. Electronic Distance Measurement. Berlin : Springer-Verlag, 1990. ISBN 3-540-51523-2. [11] Burnside, C. D. Electromagnetic Distance Measurement. London : Collins Professional and Publication Books, 1982. ISBN 0-00-383212-0. [12] Wikipedia contributors. Speed of light. Wikipedia. [Online] Wikipedia - The Free Encyclopedia., September 26, 2011. [Cited: September 26, 2011.] http://en.wikipedia.org/w/index.php?title=Speed_of_light&oldid=452569814. [13] —. Electromagnetic spectrum. Wikipedia. [Online] Wikipedia - The Free Encyclopedia, September 24, 2011. [Cited: September 26, 2011.] 115 CTU, Aalto, 2012 Bibliography http://en.wikipedia.org/w/index.php?title=Electromagnetic_spectrum&oldid=452 145728. [14] Ciddor, Philip E. Refractive index of air: new equations for the visible and near infrared. Applied Optics. Australia : Optical Society of America, 1996. [15] IAG Resolutions. The Interantional Association of Geodesy. Birmingham : IAG, 1999. [16] Wikipedia contributors. Linear regression. Wikipedia. [Online] Wikipedia The Free Encyclopedia, December 5, 2011. [Cited: December 7, 2011.] http://en.wikipedia.org/w/index.php?title=Linear_regression&oldid=464227052. [17] —. Simple linear regression. Wikipedia. [Online] Wikipedia - The Free Encyclopedia, November 29, 2011. [Cited: December 7, 2011.] http://en.wikipedia.org/w/index.php?title=Simple_linear_regression&oldid=4631 81947. [18] Hampacher, Miroslav and Radouch, Vladimír. Teorie chyb a vyrovnávací počet 20. Praha : ČVUT, 2000. ISBN 80-01-01703-6. [19] European co-operation for Accreditation. EA 4/02. EA. [Online] December 1999. [Cited: December 1, 2011.] http://www.europeanaccreditation.org/n1/doc/EA-4-02.pdf. [20] Bureau International des Poids et Mesures. GUM. BIPM. [Online] 1995. [Cited: December 1, 2011.] http://www.bipm.org/utils/common/documents/jcgm/JCGM_100_2008_E.pdf. [21] Bell, Stephanie. A Beginner's Guide to Uncertainty of measurement. WMO. [Online] August 1999. [Cited: December 1, 2011.] http://www.wmo.int/pages/prog/gcos/documents/gruanmanuals/UK_NPL/mgpg1 1.pdf. ISSN 1368-6550. [22] Internation Organization for Standardization. ISO 17123-4:. Praha : ÚNMZ, 2005. [23] International Organization for Standardization. ISO 17123-1:2010. International Standards. [Online] ISO, 2010. [Cited: October 30, 2011.] http://www.iso.org/iso/iso_catalogue/catalogue_tc/catalogue_detail.htm?csnumb er=42215. [24] United Kingdom Accreditation Service. M3003. UKAS. [Online] January 2007. [Cited: December 1, 2011.] http://www.ukas.com/library/TechnicalInformation/Pubs-Technical-Articles/Pubs-List/M3003.pdf. [25] International Organization for Standardization. ISO/IEC 17025:2005. International Standards. [Online] ISO, 2005. [Cited: December 2, 2011.] http://www.iso.org/iso/catalogue_detail.htm?csnumber=39883. [26] —. ISO 10012:2003. International Standards. [Online] ISO, 2003. [Cited: December 2, 2011.] 116 CTU, Aalto, 2012 Bibliography http://www.iso.org/iso/iso_catalogue/catalogue_ics/catalogue_detail_ics.htm?csn umber=26033. [27] —. ISO 9001:2008. ISO. [Online] ISO, 2008. [Cited: December 8, 2011.] http://www.iso.org/iso/iso_catalogue/catalogue_tc/catalogue_detail.htm?csnumb er=46486. [28] The Finnish Geodetic Institute. Finnish Geodetic Institute. Finnish Geodetic Institute. [Online] The FGI, 2012. [Cited: January 20, 2012.] http://www.fgi.fi. [29] Jokela, Jorma and Häkli, Pasi. Current Research and Development at the Nummela Standard Baseline. Interational Federation of Surveyors. [Online] October 2006. [Cited: February 24, 2012.] http://www.fig.net/pub/fig2006/papers/ps05_02/ps05_02_02_jokela_hakli_0371. pdf. [30] —. Calibration of the BEV Geodetic Baseline. Interational Federation of Surveyors. [Online] April 2010. [Cited: February 24, 2012.] http://www.fig.net/pub/fig2010/papers/ts05c%5Cts05c_jokela_hakli_et_al_3873. pdf. [31] Jokela, Jorma and Pasi, Häkli. On Tracebility of Long Distances. International Measurement Confederation. [Online] September 2009. [Cited: February 14, 2012.] http://www.imeko2009.it.pt/Papers/FP_100.pdf. [32] Lassila, Antti and Jokela, Jorma. Absolute Calibration of Quartz Bars of Väisälä Interferometer by White Light Gauge Block Interferometer. International Measurement Confederation. [Online] June 2003. [Cited: February 14, 2012.] http://www.imeko.org/publications/wc-2003/PWC-2003-TC14-026.pdf. [33] Leica Geosystems. TPS2000. Leica Geosystems. [Online] 2011. [Cited: October 30, 2011.] http://www.leicageosystems.com/downloads123/zz/tps/tps2000/brochures/TPS20 00_brochure_en.pdf. [34] Kern. Operating Instructions Mekometer ME5000. Swiss : Kern, 1994. [35] Lechner, Jiří. Nový státní etalon velkých délek Koštice. VÚGTK. [Online] 2007. [Cited: January 26, 2012.] http://www.vugtk.cz/odd25/kostice/geos.pdf. [36] VÚGTK. Metrologie a inženýrská geodézie. VÚGTK. [Online] December 5, 2011. [Cited: January 26, 2012.] http://www.vugtk.cz/odd25/ind25.html. [37] —. Státní etalon velkých délek Koštice. VÚGTK. [Online] January 19, 2010. [Cited: January 26, 2012.] http://www.vugtk.cz/odd25/kostice/. [38] EURAMET. Towards Nes Absolute Long Distance Measurement Systems In Air. Long Distance Project. [Online] February 5, 2012. [Cited: February 5, 2012.] http://www.longdistanceproject.eu/files/towards_new_absolute.pdf. [39] Wikipedia contributors. Frequency comb. Wikipedia. [Online] Wikipedia The Free Encyclopedia, February 9, 2012. [Cited: February 9, 2012.] http://en.wikipedia.org/w/index.php?title=Frequency_comb&oldid=475955044. 117 CTU, Aalto, 2012 List of used abbreviations LIST OF USED ABBREVIATIONS AG BIPM CMI CTU DORIS EA EAL EDM EDM EURAMET FGI GNSS GUM IEC IFCC ILAC ISO IUGG IUPAC IUPAP JCGM LSA MIKES OIML RMSD SCG SI SLR VLBI VÚGTK WECC Absolute Gravimetry Bureau International des Poids et Mesures Czech Metrology Institute Czech Technical University in Prague Doppler Orbitography and Radiopositioning Integrated by Satellite European co-operation for Accreditation Evaluation Assurance Level Electronic Distance Measurement Electronic Distance Meter The European Association of National Metrology Institutes Finish Geodetic Institute Global Navigation Satellite System Guide to the expression of uncertainty in measurement International Electrotechnical Commission International Federation of Clinical Chemistry and Laboratory Medicine International Laboratory Accreditation Cooperation International Organization for Standardization International Union of Geodesy and Geophysics International Union of Pure and Applied Chemistry International Union of Pure and Applied Physics Joint Committee for Guides in Metrology Least squares adjustment Centre for metrology and accreditation (in Finland) International Organization of Legal Metrology Root-mean-square deviation Superconductivity Gravimetry Système international d'unités Satellite Laser Ranging Very Long Baseline Interferometry Research Institute of Geodesy, Topography and Cartography Western European Calibration Cooperation 118 CTU, Aalto, 2012 List of figures LIST OF FIGURES Fig. 1: Accuracy vs. precision - graph .................................................................................... 12 Fig. 2: Accuracy vs. precision - targets .................................................................................. 13 Fig. 3: The prototype meter bar of the USA ........................................................................... 14 Fig. 4: A measuring metal chain ............................................................................................. 17 Fig. 5: Geodimeter NASM-2A ............................................................................................... 18 Fig. 6: Fizeau’s experiment .................................................................................................... 20 Fig. 7: A diagram of the electromagnetic spectrum ............................................................... 21 Fig. 8: A model of the daily cycle of the coefficient of refraction ......................................... 35 Fig. 9: The underground marker at 24 m ................................................................................ 65 Fig. 10: The observation pillars at 0 m (left) and 864 m (right) ............................................... 66 Fig. 11: The Kern-type forced-centering system ...................................................................... 66 Fig. 12: Quartz gauges (left) and quartz gauge comparator (right) at Tuorla Observatory ...... 68 Fig. 13: Comparisons of the length of quartz gauge no. VIII at Tuorla Observatory .............. 69 Fig. 14: The principle of the Väisälä interference comparator (interference 0-6-24) .............. 70 Fig. 15: Instruments of the Väisälä interference comparator at the pillars 0 and 1 .................. 70 Fig. 16: The mirror equipment of the Väisälä interference comparator ................................... 71 Fig. 17: A plumbing rod above an underground marker (left), a set of adaptor bars (right) .... 73 Fig. 18: Leica TCA2003 + Wild Leitz GPH1P ........................................................................ 75 Fig. 19: Kern Mekometer ME5000 + Kern RMO5035 ............................................................ 77 Fig. 20: The reflector “Wild Leitz GPH1P” ............................................................................. 78 Fig. 21: The reflector “Kern RMO5035” ................................................................................. 79 Fig. 22: Assmann-type psychrometer “Thermometer Thies Clima” ........................................ 79 Fig. 23: The aneroid barometers "Thomen altimeters" ............................................................ 80 Fig. 24: The relative humidity meter “Vaisala HM 34” ........................................................... 81 Fig. 25: Calibrating the Leica TCA2003 + the Wild Leitz GPH1P ......................................... 83 Fig. 26: Calibrating the Kern Mekometer ME5000 + the Kern RMO5035 ............................. 83 Fig. 27: Graphs – 2011-10-06, Leica TCA2003 ....................................................................... 95 Fig. 28: Graphs – 2011-10-07, Leica TCA2003 ....................................................................... 96 Fig. 29: Graphs – 2011-11-24 and 25, Kern Mekometer ME5000 .......................................... 99 Fig. 30: Graphs – 2011-11-25 and 28, Kern Mekometer ME5000 ........................................ 100 Fig. 31: Schematic location and design of the Koštice Baseline ............................................ 106 Fig. 32: Instruments on observation pillars at the Koštice Baseline ...................................... 107 Fig. 33: The set of fixing screws (left) and the detail of a fixing screw (right)...................... 107 Fig. 34: The section of forced centering of the Koštice Baseline .......................................... 108 119 CTU, Aalto, 2012 List of tabels LIST OF TABELS Table 1: Distance errors caused by omission of humidity ..................................................... 31 Table 2: The Nummela baseline lengths during the years 1947-2007 ................................... 72 Table 3: Constants used for calculations – Leica TCA2003 .................................................. 75 Table 4: Constants used for calculations – Kern Mekometer ME5000 .................................. 77 Table 5: Overview of measurements ...................................................................................... 82 Table 6: Ranges of atmospheric conditions during calibrations ............................................ 82 Table 7: Order of measured distances .................................................................................... 84 Table 8: Description of quantities contributing to the standard uncertainty .......................... 91 Table 9: Results of computations – 2011-10-06, Leica TCA2003 ......................................... 94 Table 10: Results of computations – 2011-10-07, Leica TCA2003 ......................................... 94 Table 11: Uncertainty budget of measurement – 2011-10-06, Leica TCA2003 ...................... 97 Table 12: Uncertainty budget of measurement – 2011-10-07, Leica TCA2003 ...................... 97 Table 13: Results of computations – 2011-11-24 and 25, Kern ME5000 ................................ 98 Table 14: Results of computations – 2011-11-25 and 28, Kern ME5000 ................................ 98 Table 15: Uncertainty budget of measurement – 2011-11-24 and 25, Kern ME5000 ........... 101 Table 16: Uncertainty budget of measurement – 2011-11-25 and 28, Kern ME5000 ........... 101 Table 17: Summary of results of calibrations ......................................................................... 102 Table 18: Summary of uncertainties according to EA 4/02 ................................................... 102 Table 19: Final instrumental corrections and experimental std. deviations ........................... 103 Table 20: Final instrumental corrections and modified standard deviations .......................... 103 Table 21: Uncertainty budget of measurement – Leica TCA2003 ......................................... 103 Table 22: Uncertainty budget of measurement – Kern ME5000 ........................................... 104 Table 23: Final instrumental corrections and extended uncertainties .................................... 104 Table 24: Comparison with FGI results ................................................................................. 105 Table 25: Comparison with previous calibrations of Kern ME5000...................................... 105 Table 26: Comparison of the Koštice Baseline and the Nummela Standard Baseline ........... 109 Table 27: Comparison of measurement procedures at Koštice and Nummela baselines ....... 110 Table 28: Comparison of evaluation processes at Koštice and Nummela baselines .............. 110 120 CTU, Aalto, 2012 List of appendixes LIST OF APPENDIXES Appendix 1: An example of field records of observations – Leica TCA2003 ....................... 123 Appendix 2: An example of field records of observations – Kern Mekometer ME5000 ...... 124 Appendix 3: Examples of processing observations – 2011-10-06, Leica TCA2003 ............. 125 Appendix 4: Processed observations – Leica TCA2003 ........................................................ 127 Appendix 5: Processed observations – Kern Mekometer ME5000 ........................................ 129 Appendix 6: Data of the Nummela Standard Baseline ........................................................... 131 Appendix 7: The computation scripts for Matlab R2011b (7.13.0.564) ................................ 132 Appendix 8: Graphs – 2011-10-06, Leica TCA2003 ............................................................. 141 Appendix 9: Graphs – 2011-10-07, Leica TCA2003 ............................................................. 142 Appendix 10: Graphs – 2011-11-24 and 25, Kern Mekometer ME5000 ............................... 143 Appendix 11: Graphs – 2011-11-25 and 28, Kern Mekometer ME5000 ............................... 144 Appendix 12: Example calibration certificate issued by the FGI ........................................... 145 121 CTU, Aalto, 2012 List of attachments LIST OF ELECTRONIC ATTACHMENTS All electronic attachments are stored on the enclosed CD-ROM. Attachment 1: Computations Attachment 2: Materials Attachment 3: Figures Attachment 4: Photos Attachment 5: Others – Numerical computations and graphical outputs – Used and related materials – Used figures – Photographs from measurements – Other unspecified files 122 CTU, Aalto, 2012 Appendixes Appendix 1: An example of field records of observations – Leica TCA2003 a) At the EDM instrument station b) At the reflector station 123 CTU, Aalto, 2012 Appendixes Appendix 2: An example of field records of observations – Kern Mekometer ME5000 a) At the EDM instrument station b) At the reflector station 124 CTU, Aalto, 2012 Appendixes Appendix 3: Examples of processing observations – 2011-10-06, Leica TCA2003 Distance observations - Nummela, 2011-10-06, Leica TCA2003 (S.No. 438743) Pillar Slope distance Mean distance Difference Uncertainty type A Station Target [m] [m] [mm] [mm] 24.0349 -0.06 24.0350 0.04 0 24 24.0350 24.03496 0.04 0.02 24.0349 -0.06 24.0350 0.04 Temperature observations - Nummela, 2011-10-06, Leica TCA2003 (S.No. 438743) Pillar Dry (S) [°C] Dry (T) [°C] Means (S) [°C] Mean D (S-T) [°C] Station (S) Target (T) Wet (S) [°C] Wet (T) [°C] Means (T) [°C] Mean W (S-T) [°C] 12.5 12.6 12.45 12.53 12.2 12.4 12.20 0 24 --------------- --------------- ----------------------------12.4 12.6 12.60 12.30 12.2 12.4 12.40 Pressure observations - Nummela, 2011-10-06, Leica TCA2003 (S.No. 438743) Pillar Measured Correction Corrected Difference Mean Station Target [hPa] [hPa] [hPa] [hPa] [hPa] 988.9 0 24 -9.9 979.0 --------------- --------------- --------------991.4 -12.1 -0.3 979.15 979.3 Partial water vapour pressure from psychrometer - 2011-10-06, Leica TCA2003 Pillar Dry temp. Wet. temp. Pressure Sat. w.v.p. Part. w.v.p. Rel. hum. Station Target t [°C] t´ [°C] p [hPa] E´ [hPa] e [hPa] h [%] 24 12.53 12.30 979.15 14.4 14.2 98 72 12.65 12.38 979.10 14.4 14.3 97 0 216 12.60 12.45 979.05 14.5 14.4 98 432 12.75 12.50 979.05 14.5 14.4 97 864 12.68 12.45 979.00 14.5 14.4 98 125 CTU, Aalto, 2012 Appendixes Partial water vapour pressure from rel. hum. - 2011-10-06, Leica TCA2003 Pillar Dry temp. Pressure Rel. hum. Sat. w.v.p. Part. w.v.p. Station Target t [°C] p [hPa] h [%] E [hPa] e [hPa] 24 12.53 979.15 84.6 14.6 12.3 72 12.65 979.10 86.6 14.7 12.7 0 216 12.60 979.05 87.8 14.6 12.9 432 12.75 979.05 88.9 14.8 13.1 864 12.68 979.00 89.6 14.7 13.2 Differences of partial w.v.p. - 2011-10-06, Leica TCA2003 Pillar Partial w.v.p. [hPa] Difference Distance error Station Target psych. rel. hum. [hPa] [ppm] 24 14.2 12.3 1.9 0.08 72 14.3 12.7 1.5 0.06 0 216 14.4 12.9 1.5 0.06 432 14.4 13.1 1.2 0.05 864 14.4 13.2 1.2 0.05 Comparison of dry temperatures - 2011-10-06 Pillar Dry temperatures [°C] Station (S) Target (T) Station (S) Target (T) Diff (S-T) 24 12.45 12.60 -0.15 72 12.70 12.60 0.10 0 216 12.60 12.60 0.00 432 12.75 12.75 0.00 864 12.75 12.60 0.15 126 CTU, Aalto, 2012 Appendixes Appendix 4: Processed observations – Leica TCA2003 a) 2011-10-06 (1st calibration) Processed observations - Nummela, 2011-10-06, Leica TCA2003 Pillar Distance Dry temp. Wet temp. Pressure Station Target d´ [m] t [°C] t´ [°C] p [hPa] 24 24.03496 12.53 12.30 979.15 72 72.01490 12.65 12.38 979.10 0 216 216.05456 12.60 12.45 979.05 432 432.09458 12.75 12.50 979.05 864 864.12268 12.68 12.45 979.00 0 24.03496 13.05 12.83 978.50 72 47.97968 12.90 12.73 978.55 24 216 192.01920 12.85 12.70 978.45 432 408.05930 12.83 12.68 978.70 864 840.08764 12.68 12.53 978.75 0 72.01452 13.00 12.80 977.95 24 47.97944 13.08 12.88 978.00 72 216 144.03950 13.00 12.85 978.00 432 360.07944 13.05 12.90 978.00 864 792.10714 13.00 12.88 977.80 0 216.05418 13.10 12.93 977.70 24 192.01914 13.10 13.00 977.70 216 72 144.03950 13.10 12.95 977.75 432 216.03950 13.08 12.93 977.85 864 648.06716 13.00 12.80 977.75 0 432.09420 13.18 13.00 977.70 24 408.05924 13.15 12.98 977.75 432 72 360.07936 13.18 12.95 977.70 216 216.03944 13.05 12.93 977.50 864 432.02696 13.05 12.95 977.25 0 864.12118 13.05 12.88 976.85 24 840.08622 13.00 12.85 977.05 864 72 792.10636 13.05 12.88 977.20 216 648.06670 13.10 12.85 977.15 432 432.02706 13.08 12.95 977.15 127 CTU, Aalto, 2012 Appendixes b) 2011-10-07 (2nd calibration) Processed observations - Nummela, 2011-10-07, Leica TCA2003 Pillar Distance Dry temp. Wet temp. Pressure Station Target d´ [m] t [°C] t´ [°C] p [hPa] 24 24.03548 8.88 7.08 974.20 72 72.01516 8.98 7.18 974.15 0 216 216.05530 8.85 7.28 974.15 432 432.09590 8.63 7.38 974.25 864 864.12520 9.18 7.40 974.35 0 24.03512 10.08 7.78 974.70 72 47.97980 9.95 7.60 974.75 24 216 192.02000 9.58 7.60 974.70 432 408.06068 9.33 7.55 974.55 864 840.09024 9.25 7.43 974.55 0 72.01482 10.00 7.45 975.05 24 47.97972 10.20 7.60 975.00 72 216 144.04010 9.93 7.60 975.00 432 360.08048 10.13 7.50 975.00 864 792.10948 10.23 7.50 975.15 0 216.05478 9.98 7.48 975.65 24 192.01978 10.13 7.48 975.60 216 72 144.03998 10.08 7.43 975.55 432 216.04014 10.13 7.60 975.40 864 648.06940 10.18 7.53 975.45 0 432.09504 11.28 7.65 976.00 24 408.06006 11.38 7.58 976.10 432 72 360.08012 11.30 7.88 976.00 216 216.03982 11.25 8.00 976.00 864 432.02782 11.73 8.35 975.95 0 864.12326 11.70 7.78 976.15 24 840.08822 11.53 7.68 976.15 864 72 792.10822 11.75 7.78 976.15 216 648.06794 11.53 8.00 976.15 432 432.02800 11.60 8.05 976.20 128 CTU, Aalto, 2012 Appendixes Appendix 5: Processed observations – Kern Mekometer ME5000 a) 2011-11-24 and 25 (1st calibration) Processed observations - 2011-11-24 and 25, Kern ME5000 Pillar Distance Dry temp. Wet temp. Pressure Station Target d´ [m] t [°C] t´ [°C] p [hPa] 24 24.03530 7.25 5.88 999.70 72 72.01605 6.73 5.95 999.30 0 216 216.05860 6.55 6.08 998.95 432 432.10200 6.43 6.13 998.75 864 864.13675 6.50 6.23 998.65 0 24.03530 6.73 6.50 997.35 72 47.98035 6.75 6.50 997.85 24 216 192.02290 6.65 6.43 998.00 432 408.06615 6.68 6.45 998.05 864 840.10105 6.55 6.30 998.20 0 72.01560 6.98 6.73 996.90 24 47.98050 7.00 6.75 997.00 72 216 144.04255 6.95 6.73 997.00 432 360.08565 7.00 6.75 997.25 864 792.12035 6.83 6.58 997.50 0 216.05815 6.25 5.93 998.05 24 192.02300 6.20 5.90 998.00 216 72 144.04235 6.08 5.85 997.80 432 216.04340 6.15 5.98 997.65 864 648.07825 6.40 6.13 997.60 0 432.10195 5.68 5.53 996.35 24 408.06670 5.58 5.45 995.85 432 72 360.08600 5.70 5.58 995.75 216 216.04340 5.75 5.68 995.55 864 432.03460 6.00 5.95 995.20 0 864.13475 7.35 7.30 994.30 24 840.09990 6.95 6.88 994.45 864 72 792.11965 6.78 6.73 994.65 216 648.07740 6.58 6.48 994.50 432 432.03465 6.33 6.28 995.15 129 CTU, Aalto, 2012 Appendixes b) 2011-11-25 and 28 (2nd calibration) Processed observations - 2011-11-25 and 28, Kern ME5000 Pillar Distance Dry temp. Wet temp. Pressure Station Target d´ [m] t [°C] t´ [°C] p [hPa] 24 24.03525 7.73 7.58 993.00 72 72.01570 7.80 7.68 992.75 0 216 216.05785 7.93 7.80 992.60 432 432.10040 7.93 7.78 992.40 864 864.13385 8.00 7.85 992.30 0 24.03520 8.13 7.98 990.40 72 47.98015 8.18 7.95 990.20 24 216 192.02230 8.00 7.80 990.20 432 408.06475 8.00 7.75 990.15 864 840.09790 7.95 7.63 990.05 0 72.01540 7.63 6.95 989.25 24 47.98040 7.68 7.08 989.50 72 216 144.04210 7.65 7.25 989.80 432 360.08460 7.70 7.38 989.90 864 792.11770 7.88 7.55 990.05 0 216.05790 1.55 0.38 975.85 24 192.02270 1.93 0.40 975.85 216 72 144.04215 2.00 0.43 975.95 432 216.04315 1.88 0.28 976.45 864 648.07755 1.68 0.18 976.85 0 432.10150 1.75 0.10 978.85 24 408.06630 1.70 0.00 978.30 432 72 360.08560 1.68 0.00 978.10 216 216.04315 1.83 0.13 977.90 864 432.03440 1.48 0.13 977.60 0 864.13625 1.65 0.13 979.85 24 840.10110 1.63 0.18 980.10 864 72 792.12045 1.68 0.15 980.20 216 648.07805 1.78 0.30 980.35 432 432.03480 1.83 0.50 980.90 130 CTU, Aalto, 2012 Appendixes Appendix 6: Data of the Nummela Standard Baseline Data of the Nummela Standard Baseline - valid for 2011-10 Pillar Pillar height [m] Proj. corr. [mm] True distance Station Target Station Target Back Forward D [m] 24 1.637 1.523 -1.540 -0.461 24.033218 72 1.637 1.293 -1.540 1.627 72.014950 0 216 1.637 0.600 -1.540 -0.499 216.053128 432 1.637 -0.438 -1.540 1.476 432.095283 864 1.637 -2.486 -1.540 0.827 864.122864 0 1.523 1.637 -1.540 -0.461 24.033218 72 1.523 1.293 0.461 1.627 47.981732 24 216 1.523 0.600 0.461 -0.499 192.019910 432 1.523 -0.438 0.461 1.476 408.062065 864 1.523 -2.486 0.461 0.827 840.089646 0 1.293 1.637 -1.540 1.627 72.014950 24 1.293 1.523 0.461 1.627 47.981732 72 216 1.293 0.600 -1.627 -0.499 144.038178 432 1.293 -0.438 -1.627 1.476 360.080333 864 1.293 -2.486 -1.627 0.827 792.107914 0 0.600 1.637 -1.540 -0.499 216.053128 24 0.600 1.523 0.461 -0.499 192.019910 216 72 0.600 1.293 -1.627 -0.499 144.038178 432 0.600 -0.438 0.499 1.476 216.042155 864 0.600 -2.486 0.499 0.827 648.069736 0 -0.438 1.637 -1.540 1.476 432.095283 24 -0.438 1.523 0.461 1.476 408.062065 432 72 -0.438 1.293 -1.627 1.476 360.080333 216 -0.438 0.600 0.499 1.476 216.042155 864 -0.438 -2.486 -1.476 0.827 432.027581 0 -2.486 1.637 -1.540 0.827 864.122864 24 -2.486 1.523 0.461 0.827 840.089646 864 72 -2.486 1.293 -1.627 0.827 792.107914 216 -2.486 0.600 0.499 0.827 648.069736 432 -2.486 -0.438 -1.476 0.827 432.027581 131 CTU, Aalto, 2012 Appendixes Appendix 7: The computation scripts for Matlab R2011b (7.13.0.564) %% 1) Software information clc, clear all, format long g; title='Calibration of the EDM instrument'; release='2012-01-05'; soft='Matlab 7.13.0.564 (R2011b)'; % script purpose % YEAR-MONTH-DATE of release % software to run the script %% 2) Data source file identification (Microsoft Excel file) file='111125_28.xlsx'; % Data source file %% 3) Load input data from Microsoft Excel file (*.xls, *.xlsx file) % Load information [no,info] = xlsread(file,'info','B3:B7'); edm = info(1); % prism = info(2); % bsline = info(3); % date = info(4); % weather = info(5); % EDM instrument / Total station Reflecting prism Calibration baseline YEAR-MONTH-DATE of measurement Weather conditions % Load constants const = xlsread(file,'info','E4:E14'); lam = const(1); t_r = const(2); p_r = const(3); h_r = const(4); n_r = const(5); ac0 = const(6); sc0 = const(7); hi = const(8); hp = const(9); A = const(10); R = const(11); EDM carrier wavelength [nm] Reference temperature [°C] Reference atm. pressure [hPa] Reference rel. humidity [%] Reference refractive index Initial additive constant [mm] Initial scale correction [ppm] EDM instrument height [m] Reflecting prism height [m] Assman psychrometer constant Radius of the Earth [m] % % % % % % % % % % % % Load standard baseline data base = xlsread(file,'baseline','C5:G34'); h_s = base(:,1); % h_t = base(:,2); % c_b = base(:,3); % c_f = base(:,4); % D = base(:,5); % Station pillar heights Target pillar heights Proj. corrections back Proj. corrections forward True distances [m] [m] [mm] [mm] [m] % Load observations obs = xlsread(file,'processed','C5:F34'); d = obs(:,1); % t_d = obs(:,2); % t_w = obs(:,3); % p = obs(:,4); % Mean Mean Mean Mean [m] [°C] [°C] [hPa] of of of of all distances dry temperatures wet temperatures atm. pressures %% 4) The first velocity correction % Saturated water vapor pressures [hPa] Ew = (1.0007+3.46e-6.*p).*6.1121.*exp(17.502.*t_w./(240.97+t_w)); % For t_w Ed = (1.0007+3.46e-6.*p).*6.1121.*exp(17.502.*t_d./(240.97+t_d)); % For t_d e = Ew-A.*p.*(t_d-t_w); % Partial water vapor pressures [hPa] h = e./Ed.*100; % Relative humidity [%] 132 CTU, Aalto, 2012 Appendixes % Reference saturated water vapor pressure [hPa] Ed_r = (1.0007+3.46e-6*p_r)*6.1121*exp(17.502*t_r/(240.97+t_r)); e_r = Ed_r*h_r/100; % Reference partial water vapor pressure [hPa] T = 273.15+t_d; T_r = 273.15+t_r; lam = lam/1000; % Temperatures [K] % Reference temperature [K] % Instrument carrier wavelength [um] % Group refractivity N_g = 287.6155+4.88660/lam^2+0.06800/lam^4; N_r1 = ((273.15/1013.25)*N_g*p_r/T_r)-11.27*e_r/T_r; N_L = ((273.15/1013.25).*N_g.*p./T)-11.27.*e./T; % For standard cond. % For reference cond. % For ambient cond. % Group refractive index n_r1 = N_r1/1e6+1; % For reference conditions n_L = N_L/1e6+1; % For ambient conditions % Computed vs. given reference refractive index (check) n_diff = abs(n_r-n_r1); % First velocity corrections if n_r~=0 K_1 = d.*((n_r-n_L)./n_L); else K_1 = d.*((n_r1-n_L)./n_L); end d_1 = d+K_1; d_1=d.*(n_r./n_L); % From given n_r [m] % From computed n_r1 [m] % Corrected distances [m] % Direct computation of corr. distances (check) %% 5) The vertical geometrical correction h_s = h_s+hi; h_t = h_t+hp; % Station pillar height + instrument height [m] % Target pillar height + prism height [m] for i = 1:length(d_1) ds(i,1)=sqrt((d_1(i)^2-(h_t(i)-h_s(i))^2)/((1+h_s(i)/R)*(1+h_t(i)/R)))-d_1(i); end ds; d_2 = d_1+ds; % Vertical geometrical correction % Corrected distances [m] [m] %% 6) The additive constant (Least-squares adjustment) if ac0 ~= 0 d2 = d2+ac0/1e3; end [ac1,m_ac1] = ac(d_2); d_3 = d_2+ac1; [ac2,m_ac2] = ac(d_3); % Applying initial additive constant % Computation of additive constant [m] % Corrected distances [m] % Control computation of additive constant [m] if abs(ac2) > 1e-9 % Test if control additive constant is 0 error('Control computation of additive constant exceed the limit 1e-9.') end %% 7) The scale correction if sc0 ~= 0 d3 = d3+sc0/1e6.*d3; end % Applying initial scale correction 133 CTU, Aalto, 2012 d_4 = d_3+(c_b+c_f)/1e3; diff_d_4 = d_4-D; % Applying projection corrections % Differences in distances (measured-true) [m] [sc1,m_sc1,res1] = sc(d_4,D); d_5 = d_4+sc1.*d_4; [sc2,m_sc2] = sc(d_5,D); Appendixes % Computation of scale correction [m/m] % Corrected distances [m] % Control computation of scale correction [m/m] if abs(sc2) > 1e-9 % Test if control scale correction is 0 error('Control computation of scale correction exceed the limit 1e-9.') end %% 8) The root-mean-square deviation (RMSD) RMSD = sqrt((sum(res1.^2))/length(D)); % RMSD [m] %% 9) The regression analysis d_25 = d_2+(c_b+c_f)/1e3; diff_d_25 = d_25-D; % Applying projection corrections % Differences in distances (measured-true) [m] [alf,bet,m_alf,m_bet,RMSD_r,p,y,del,p3,y3,del3,RMSD_3] = reg(d_25,D); RMSD_r; % RMSD of simple linear regression RMSD_3; % RMSD of cubic regression %% 10) Program outputs % Write results to the source file sheet "results" xlswrite(file,ac1*1e3,'results','B5:B5') % Additive constant [mm] xlswrite(file,m_ac1*1e3,'results','C5:C5') % STD of additive constant [mm] xlswrite(file,sc1*1e6,'results','D5:D5') % Scale correction [ppm] xlswrite(file,m_sc1*1e6,'results','E5:E5') % STD of scale correction [ppm] xlswrite(file,RMSD*1e3,'results','F5:F5') % RMS deviation [mm] xlswrite(file,alf*1e3,'results','B6:B6') xlswrite(file,m_alf*1e3,'results','C6:C6') xlswrite(file,bet*1e6,'results','D6:D6') xlswrite(file,m_bet*1e6,'results','E6:E6') xlswrite(file,RMSD_r*1e3,'results','F6:F6') % % % % % Alfa coefficient STD of alfa Beta coefficient STD of beta RMS deviation xlswrite(file,K_1.*1e3,'results','J5:J34') xlswrite(file,ds.*1e3,'results','K5:K34') xlswrite(file,diff_d_25.*1e3,'results','L5:L34') xlswrite(file,-res1.*1e3,'results','M5:M34') xlswrite(file,RMSD_3.*1e3,'results','F7:F7') % % % % First velocity corr. Ver. geometrical corr. Distance differences Residuals % RMS deviation % Create and save graphs to folder "Graphs" graph(diff_d_25,diff_d_4,D,info,ac1,sc1,res1,p,y,del,p3,y3,del3) % Display to the Matlab screen T = datestr(now,31); disp ' ' disp(['Date and time: ',T]) disp ' ' disp(['Program version: ',release]) disp ' ' disp 'Program terminated. All computations finished.' disp ' ' disp 'Results have been written into the source file.' disp 'Graphs have been saved into the working folder.' 134 [mm] [mm] [ppm] [ppm] [mm] [mm] [mm] [mm] [mm] [mm] CTU, Aalto, 2012 Appendixes function [ac,m_ac]=ac(d) % FUNCTION: Computation of additive constant % INPUT: d - distances after velocity and geom. correction % OUTPUT: ac - additive constant % m_ac - standard deviation of ac % Vector of measurements L L=d; % Vector of unknowns X0 X0=[ L(1) %0-24 L(7) %24-72 L(13) %72-216 L(19) %216-432 L(25) %432-864 0]; %c % Vector L0 L0=[X0(1) X0(1)+X0(2) X0(1)+X0(2)+X0(3) X0(1)+X0(2)+X0(3)+ X0(4) X0(1)+X0(2)+X0(3)+ X0(4)+X0(5) X0(1) X0(2) X0(2)+X0(3) X0(2)+X0(3)+X0(4) X0(2)+X0(3)+X0(4)+X0(5) X0(1)+X0(2) X0(2) X0(3) X0(3)+X0(4) X0(3)+X0(4)+X0(5) X0(1)+X0(2)+X0(3) X0(2)+X0(3) X0(3) X0(4) X0(4)+X0(5) X0(1)+X0(2)+X0(3)+X0(4) X0(2)+X0(3)+X0(4) X0(3)+X0(4) X0(4) X0(5) X0(1)+X0(2)+X0(3)+X0(4)+X0(5) X0(2)+X0(3)+X0(4)+X0(5) X0(3)+X0(4)+X0(5) X0(4)+X0(5) X0(5)]; % % % % % % % % % % % % % % % % % % % % % % % % % % % % % % 0-24 0-72 0-216 0-432 0-864 24-0 24-72 24-216 24-432 24-864 72-0 72-24 72-216 72-432 72-864 216-0 216-24 216-72 216-432 216-864 432-0 432-24 432-72 432-216 432-864 864-0 864-24 864-72 864-216 864-432 % Vector l l=L-L0; % Plan A=[1 0 1 1 1 1 1 1 1 1 1 0 0 1 0 1 0 1 0 1 1 1 0 1 0 0 matrix 0 0 0 0 0 0 1 0 0 1 1 0 1 1 1 0 0 0 0 0 0 1 0 0 1 1 0 1 1 1 0 0 0 0 0 0 1 0 0 A -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 135 [m] [m] [m] CTU, 0 0 1 0 0 0 0 1 0 0 0 0 1 0 0 0 0 0 0 1 1 0 0 0 1 1 0 0 0 1 1 0 0 0 1 1 1 1 1 0 0 1 1 1 0 0 1 1 1 0 0 1 1 0 0 0 1 1 1 1 1 1 0 1 1 1 1 0 0 1 0 0 0 0 1 0 0 0 0 1 1 1 1 1 1 Aalto, 2012 Appendixes -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1]; % Weight matrix P m0_apr=1; % Apriori unit std md=0.001/sqrt(5); % Apriori std of measured distance P=m0_apr^2.*diag(ones(1,length(L)).*md^2)^-1; % Weight matrix % Least-squares adjustment N=A'*P*A; n=A'*P*l; x=N^(-1)*n; X=X0+x; ac=X(6,1); % Additive constant v1=A*x-l; % 1st corrections m0_apost=sqrt((v1'*P*v1)/(length(L)-5)); % Aposteriori unit std if (m0_apost < m0_apr) m0=m0_apost; else m0=m0_apr; end % Standard deviation of additive constant Qxx=m0^2.*N^(-1); Qx=sqrt(diag(Qxx)); m_ac=Qx(6,1); function [sc,m_sc,res]=sc(d,D) % FUNCTION: Computation of scale correction % INPUT: d - distances after all corrections % D - true distances % OUTPUT: sc - scale correction % m_sc - standard deviation of sc % res - residuals [m] [m] [m] [m] [m] x = D; y = D-d; beta = sum(x.*y)/sum(x.*x); % Manual computation [beta,m_B,res] = regress(y,x,0.311); % Matlab function sc=beta; % Scale correction m_sc=m_B(2)-sc; % Standard deviation of scale correction 136 CTU, Aalto, 2012 Appendixes function [alf,bet,m_alf,m_bet,RMSD_r,p,y,del,p3,y3,del3,RMSD_3]=reg(d,D) % FUNCTION: Computation regression analysis % INPUT: d - distances after all corrections [m] % D - true distances [m] % OUTPUT: a lot of staffs L = d; L0 = D; l = L0-L; n = length(L0); % % % % Measured distances True distances Differences l Number of distances %% 1) Matrix computation (control computation) A = [sum(L0.^2) sum(L0);sum(L0) 30]; b = [sum(l.*L0);sum(l)]; c = inv(A)*b; % Coefficents %% 2) Matlab fuctions (control computation) [p,s] = polyfit(L0, l, 1); % Lin. regression [y,del] = polyval(p,L0,s); % Statistics std = sqrt(diag(inv(s.R)*inv(s.R')).*s.normr.^2./s.df); % Std deviations %% 3) By elements D = n*sum(L0.^2)-(sum(L0))^2; % Denominator alf = (sum(L0.^2) * sum(l) - sum(L0)*sum(L0.*l))/D; % Coefficient alfa [m] bet = (n*sum(L0.*l)-sum(L0)*sum(l))/D; % Coefficient beta [m/m] for i = 1:n v_y(i,1) = alf+bet.*L0(i)-l(i); end v_y; % Residuals [m] sum(v_y); sum(L0.*v_y); pom = sum(l.^2)-sum(l)*alf-sum(L0.*l)*bet; sum(v_y.^2)-pom; m_y = sqrt((sum(v_y.^2))/(n-2)); RMSD_r = sqrt((sum(v_y.^2))/n); Q11 Q22 m_alf m_bet = = = = sum(L0.^2)/D; n/D; m_y*sqrt(Q11); m_y*sqrt(Q22); %Check - should be 0 %Check - should be 0 %Check - should be 0 % Empirical deviation [m] % Root-mean-square deviation (RMSD) [m] % Standard deviation of alfa [m] % Standard deviation of beta [m/m] %% 4) Cubic regression [p3,s3] = polyfit(L0, l, 3); % Cubic regression [y3,del3] = polyval(p3,L0,s3); % Statistics std3 = sqrt(diag(inv(s3.R)*inv(s3.R')).*s3.normr.^2./s3.df); % Std dev. for i = 1:n res3(i)=(p3(1).*L0(i)^3+p3(2).*L0(i)^2+p3(3).*L0(i)+p3(4))-l(i); end res3; % Residuals [m] RMSD_3 = sqrt((sum(res3.^2))/n); % RMSD [m] 137 CTU, Aalto, 2012 Appendixes function graph(diff_d_25,diff_d_4,D,info,ac,sc,res,p,y,del,p3,y3,del3) mkdir 'Graphs' cd './Graphs' %% The additive constant figure(1) %set(1,'Visible','off') hold on, grid on, box on title({['\bfAdditive constant analysis\rm'];[char(info(1)),' + ',char(info(2))];[char(info(3)),', ',char(info(4)),', ',char(info(5))]}) xlabel('\bfDistance [m]') ylabel('\bfDifference (measured-true) [mm]') scatter(D(1:5),diff_d_25(1:5).*1e3,'ob','filled') scatter(D(6:10),diff_d_25(6:10).*1e3,'og','filled') scatter(D(11:15),diff_d_25(11:15).*1e3,'or','filled') scatter(D(16:20),diff_d_25(16:20).*1e3,'oc','filled') scatter(D(21:25),diff_d_25(21:25).*1e3,'om','filled') scatter(D(26:30),diff_d_25(26:30).*1e3,'ok','filled') fplot(@(x) -ac*1e3,[0,900],'b') if sc>1e-6 axis([0,900,-2.5,+0.5]) %Axis for Leica TCA2003 else axis([0,900,-1.0,+1.0]) %Axis for Kern Mekometer ME5000 end set(gca,'xtick',[0 72 216 432 648 864]) legend('From 0','From 24','From 72','From 216','From 432', 'From 864','Location','NorthEast') print('-dpng','-r300',[char(info(4)),'_1_ac']); %% The scale correction figure(2) %set(2,'Visible','off') hold on, grid on, box on title({['\bfScale correction analysis\rm'];[char(info(1)),' + ',char(info(2))];[char(info(3)),', ',char(info(4)),', ',char(info(5))]}) xlabel('\bfDistance [m]') ylabel('\bfDifference (measured-true) [mm]') scatter(D(1:5),diff_d_4(1:5).*1e3,'ob','filled') scatter(D(6:10),diff_d_4(6:10).*1e3,'og','filled') scatter(D(11:15),diff_d_4(11:15).*1e3,'or','filled') scatter(D(16:20),diff_d_4(16:20).*1e3,'oc','filled') scatter(D(21:25),diff_d_4(21:25).*1e3,'om','filled') scatter(D(26:30),diff_d_4(26:30).*1e3,'ok','filled') fplot(@(x) -sc*1e3*x,[0,900],'b') if sc>1e-6 axis([0,900,-2.5,+0.5]) %Axis for Leica TCA2003 else axis([0,900,-1.0,+1.0]) %Axis for Kern Mekometer ME5000 end set(gca,'xtick',[0 72 216 432 648 864]) legend('From 0','From 24','From 72','From 216','From 432','From 864','Location','NorthEast') print('-dpng','-r300',[char(info(4)),'_2_sc']); 138 CTU, Aalto, 2012 Appendixes %% Residuals figure(3) %set(3,'Visible','off') hold on, grid on, box on title({['\bfResiduals analysis\rm'];[char(info(1)),' + ',char(info(2))];[char(info(3)),', ',char(info(4)),', ',char(info(5))]}) xlabel('\bfDistance [m]') ylabel('\bfResidual (corrected-true) [mm]') scatter(D(1:5),res(1:5).*1e3,'ob','filled') scatter(D(6:10),res(6:10).*1e3,'og','filled') scatter(D(11:15),res(11:15).*1e3,'or','filled') scatter(D(16:20),res(16:20).*1e3,'oc','filled') scatter(D(21:25),res(21:25).*1e3,'om','filled') scatter(D(26:30),res(26:30).*1e3,'ok','filled') if sc>1e-6 axis([0,900,-1.0,+1.0]) %Axis for Leica TCA2003 else axis([0,900,-1.0,+1.0]) %Axis for Kern Mekometer ME5000 end set(gca,'xtick',[0 72 216 432 648 864]) legend('From 0','From 24','From 72','From 216','From 432','From 864','Location','NorthEast') print('-dpng','-r300',[char(info(4)),'_3_res']); %% Simple linear regression figure(4) %set(4,'Visible','off') hold on, grid on, box on title({['\bfSimple linear regression\rm'];[char(info(1)),' + ',char(info(2))];[char(info(3)),', ',char(info(4)),', ',char(info(5))]}) xlabel('\bfDistance [m]') ylabel('\bfDifference (measured-true) [mm]') scatter(D(1:5),diff_d_25(1:5).*1e3,'ob','filled') scatter(D(6:10),diff_d_25(6:10).*1e3,'og','filled') scatter(D(11:15),diff_d_25(11:15).*1e3,'or','filled') scatter(D(16:20),diff_d_25(16:20).*1e3,'oc','filled') scatter(D(21:25),diff_d_25(21:25).*1e3,'om','filled') scatter(D(26:30),diff_d_25(26:30).*1e3,'ok','filled') plot(D,-(y+2.*del).*1e3,'r+') plot(D,-(y-2.*del).*1e3,'r+') refcurve(-p.*1e3) if sc>1e-6 axis([0,900,-2.5,+0.5]) %Axis for Leica TCA2003 else axis([0,900,-1.0,+1.0]) %Axis for Kern Mekometer ME5000 end set(gca,'xtick',[0 72 216 432 648 864]) legend('From 0','From 24','From 72','From 216','From 432','From 864','P=95% interval','Location','NorthEast') print('-dpng','-r300',[char(info(4)),'_4_sim']); 139 CTU, Aalto, 2012 Appendixes %% Cubic regression figure(5) %set(4,'Visible','off') hold on, grid on, box on title({['\bfCubic regression\rm'];[char(info(1)),' + ',char(info(2))];[char(info(3)),', ',char(info(4)),', ',char(info(5))]}) xlabel('\bfDistance [m]') ylabel('\bfDifference (measured-true) [mm]') scatter(D(1:5),diff_d_25(1:5).*1e3,'ob','filled') scatter(D(6:10),diff_d_25(6:10).*1e3,'og','filled') scatter(D(11:15),diff_d_25(11:15).*1e3,'or','filled') scatter(D(16:20),diff_d_25(16:20).*1e3,'oc','filled') scatter(D(21:25),diff_d_25(21:25).*1e3,'om','filled') scatter(D(26:30),diff_d_25(26:30).*1e3,'ok','filled') plot(D,-(y3+2.*del3).*1e3,'r+') plot(D,-(y3-2.*del3).*1e3,'r+') refcurve(-p3.*1e3) if sc>1e-6 axis([0,900,-2.5,+0.5]) %Axis for Leica TCA2003 else axis([0,900,-1.0,+1.0]) %Axis for Kern Mekometer ME5000 end set(gca,'xtick',[0 72 216 432 648 864]) legend('From 0','From 24','From 72','From 216','From 432','From 864','P=95% interval','Location','NorthEast') print('-dpng','-r300',[char(info(4)),'_5_pol']); cd '../' 140 CTU, Aalto, 2012 Appendixes Appendix 8: Graphs – 2011-10-06, Leica TCA2003 141 CTU, Aalto, 2012 Appendixes Appendix 9: Graphs – 2011-10-07, Leica TCA2003 142 CTU, Aalto, 2012 Appendixes Appendix 10: Graphs – 2011-11-24 and 25, Kern Mekometer ME5000 143 CTU, Aalto, 2012 Appendixes Appendix 11: Graphs – 2011-11-25 and 28, Kern Mekometer ME5000 144 CTU, Aalto, 2012 Appendixes Appendix 12: Example calibration certificate issued by the FGI GEODEETTINEN LAITOS KANSALLINEN MITTANORMAALILABORATORIO GEODETISKA INSTITUTET NATIONELLT MÄTNORMALLABORATORIUM FINNISH GEODETIC INSTITUTE NATIONAL STANDARDS LABORATORY PL 15 (Geodeetinrinne 2), FI-02431 MASALA, FINLAND KALIBROINTITODISTUS KALIBRERINGSBEVIS Certificate of Calibration Numero - Nummer: Number 20 / 2009 Sivu - Sida Page Tilaaja - Uppdragsgivare: Customer Zhengzhou Surveying and Mapping Institute. Kalibroitu laite - Kalibrerat instrument: Calibrated instrument Electronic distance meter. Valmistaja - Tillverkare: Manufactured by Wild. Tyyppi - Typ: Model DI2002. Sarjanumero - Serienummer: Serial number 180495. Kalibrointipäivä - Kalibreringsdatum: Date of calibration June 23–25, 2009. Päiväys - Datum: Date July 3, 2009. 1(2) Allekirjoitukset - Underskrifter: Signatures Director General Risto Kuittinen Specialist reseach scientist Jorma Jokela Liitteitä - Bilagor: Documents attached – A National Standards Laboratory is responsible for the maintaining of a national standard and its traceability to SI-units. The Laboratory is also responsible for the dissemination of the units to other reference standards. As prescribed in the Law no. 581/2000, the Finnish Geodetic Institute maintains standards for measurements in geodesy and photogrammetry, and acts as the National Standards Laboratory of Length and Acceleration of Free Fall. The Certificate may not be reproduced other than in full, except with the prior written approval of the Finnish Geodetic Institute. 145 CTU, Aalto, 2012 Appendixes GEODEETTINEN LAITOS Finnish Geodetic Institute PL 15 (Geodeetinrinne 2) FI-02431 MASALA FGI Certification of Calibration no. 20 / 2009, page 2(2) Calibration of electronic distance meter Wild DI2002 n:o 180495 at the Nummela Standard Baseline of the Finnish Geodetic Institute on June 23–25, 2009. Measured distances: Three calibrations in three days, in each of them all the 15 pillar intervals 24 m to 864 m have been measured from both ends. EDM instrument and prism reflectors fixed on observation pillars using permanently installed Kern forced-centring plates and adapter plates with 5/8” fixing screws. Measurements with two precise prism reflectors. Measurements were performed by Messrs. Xue Ying, Fu Ziao and Fan Gang, assisted and guided by Mr. Jorma Jokela. Other measurements: Temperature observations with psychrometers at the EDM instrument (dry, wet) and at the reflector (dry). Air pressure measurements with an aneroid barometer at the EDM instrument. W eather was during calibrations clear and sunny, temperature +18.7 °C – +23.6 °C, air pressure 101.32 kPa – 101.60 kPa, relative humidity 24 % – 62 %. True distances: Interference measurements of the Nummela Standard Baseline in autumn 2007. Projection measurements at the baseline between underground benchmarks and observation pillars on May 11 – 14, 2009, by Mr. Joel Ahola and Ms. Sonja Nyberg, and on June 29 – July 1, 2009, by Mr. Jorma Jokela and Ms. Sonja Nyberg. Computation: Weather corrections, vertical geometrical corrections, projection corrections. Additive constant is determined as an unknown in the first adjustment. Scale correction is determined in a least-squares adjustment by fitting the corrected observed values with the true distances. Results (additive constant and scale correction, 1-σ uncertainty) of the three calibrations were: June 23: –0.478 mm ±0.131 mm ja +0.424 mm/km ±0.146 mm/km, June 24: –0.430 mm ±0.085 mm ja +0.802 mm/km ±0.100 mm/km. June 25: –0.211 mm ±0.062 mm ja +0.245 mm/km ±0.078 mm/km. The result of calibration is unweighted average of these. Based on interference measurements and projection measurements, standard uncertainty of true values is estimated to ±0.15 mm/km, which is included in the total uncertainty of result of calibration. Previous experience is also used in estimation of total uncertainty. Result of calibration, with extended (2-σ) uncertainties: Additive constant: –0.37 mm ±0.16 mm. Scale correction: +0.49 mm/km ±0.44 mm/km. Used methods meet the requirements of ISO 9001 and ISO 17025 quality standards 146 CTU, Aalto, 2012 Appendixes 147