Rooflights Brochure - The rooflight Company
Transcription
Rooflights Brochure - The rooflight Company
The Lantern Rooflight, Wiltshire. For the full case study visit: www.therooflightcompany.co.uk/case-studies Rooflights Brochure For beautifully designed, naturally lit flat roof environments. Issue No. 1: July 2013 Contents The Walk on Rooflight 9 The Added Security Rooflight 25 The Lantern Rooflight 13 The Polyedge Rooflight 29 The Pyramid Rooflight 17 Accessories 30 Secured by Design 21 Project Portfolio 34 2 Walk on Rooflight. For case studies visit www.therooflightcompany.co.uk/case-studies Founded in 1993 by architect, Peter King RIBA, created the original conservation roof window (the Conservation Rooflight®), which continues to lead the marketplace as the best product in its class. Today, this award-winning organisation is developing in the field of contemporary architecture and interior design. This was underlined when the Rooflight Company commenced production of its innovation - neo™. Featuring a sleek design and flush edge-to-edge glazing, neo™ has unique properties and a frameless, minimalist appearance which complements modern architecture perfectly. Designed entirely from the specifier’s point of view, its clean lines merge unobtrusively with the roof and provide unobscured views from the interior. Underpinned by this ethos of innovative design, it is continuously evolving its product range and breaking new ground with its acclaimed, industry-leading concepts. Bespoke Lantern Rooflight, Twickenham. For the full case study visit: www.therooflightcompany.co.uk/case-studies 3 The Rooflight Experts Standards and Performance Kite Mark The BSI Kitemark scheme for insulating glass units is recognised as the best way to identify certified, quality safety glass for use in buildings. We are certified to BS EN 1279-2 and BS EN 1279-3. Secured by Design The Rooflight Company designed the first rooflight to be Secured by Design certified to Loss Prevention Standard 1175-6 Level 3. See pages 20-23. ISO 9001 The Rooflight Company is ISO 9001 certified, meaning that all our roof windows are manufactured to this Quality Management standard. Residential Property Oxford. Walk on Rooflights allow natural light ingress to spaces below whilst creating a usable space above. Pyramid and Lantern Rooflights were specified to provide light and ventilation to a large flat roof extension in this updated mansion house. 4 Robinsons Brewery Visitors Centre. A total of eighteen modular sections were joined together to create one large Lantern Rooflight. Two Pyramid 1200s were installed on this National Trust property in Surrey along with two special Lanterns. Design Focus Great design is at the heart of all of our rooflights. Each of our rooflights are aesthetically pleasing and features fine lines, a low-profile and a high quality finish both inside and out. That’s why we’ve been specified by many of the Top 100 architects practices such as Zaha Hadid, Purcell Miller Tritton and Will Alsop, to name but a few. Durability Made from mild steel, each of our rooflights is designed to last. We provide a glazing guarantee of 5 years and 12 years frame guarantee on every rooflight. Choice & Sizes The Rooflight Company offers the UK’s widest range of roof windows, rooflights and bespoke designs. Whatever shape your roof window project is, we’ll have the perfect fit. Neat & Easy to Install All of our rooflights are simple to install and technical advice is always on hand from our technically-trained team should you require it. Service As a company founded by an architect, we are unique in truly understanding the needs of architects. Our in-house sales and design teams have the capability to take your brief and translate it into a complete solution including technical drawings. Designed & Assembled in the UK The Rooflight Company is based in Oxfordshire and we are proud to be part of the British Manufacturing Industry. Employing over 60 staff, we design and assemble all of our rooflights here in the UK. 5 Specification details for all rooflights How the Thermoliner® works The unique and patented Thermoliner® thermally decoupled lining made from UPVC ensures condensation control. It is integral to the rooflight frame, inconspicuous and rebated for 12.5mm plasterboard or timber linings to aid internal finishing. The integral drainage slots ensure that any condensation that may occur is drained out of the building. The Thermoliner® is available in black, white, dark and light grey to match BS colours detailed below. All rooflights are constructed from a mild steel with protective coating, polyester-powder coated paint and condensation control from the patented Thermoliner®. Glazing The standard glazing specification for rooflights achieves a centre pane u-value (Ug) of 1.2Wm2K or 1.0 Wm2k for Walk on Rooflights in accordance with EN 673:2011. The u-value results are for the glazing orientated in the vertical pane. Rooflight colour to match any roof covering Black (RAL 9005) is our standard colour but white (RAL 9010), dark grey (BS00A13) and light grey (BS 00A09) are available and can be specified with matching silicone and Thermoliner®. However any colour of paint for the Flat Roof range can be specified according to project requirements. Please specify colour: WHITE (RAL 9010) 6 DARK GREY (BS 00A13) LIGHT GREY (BS 00A09) BLACK (RAL 9005) The Walk on Rooflight has a unique draining system. Any condensation which forms within the rooflight is channelled out through the drainage pipes and out of the casement. Jamb section showing Thermoliner® Thermally-decoupled lining and interior reveal 4. 1. 2. 12. 13. 15. 14. 5. 3. 6. 11. 16. 10. 9. 8. 7. Parts List 1. 2. 3. 4. 5. 6. 7. 8. Roof window casement Roof window baseplate Roof window thermoliner Roof window double glazing panel Roof window timber lining Timber reveal Plaster board and skim Ply packer 9. 10. 11. 12. 13. 14. 15. 16. Deck Structural supports Insulation Packer Structural boards Lead Roofing membrane Vapour barrier 7 the Walk on Rooflight the Walk on Rooflight Walk on Rooflight, Oxfordshire. For the full case study visit: www.therooflightcompany.co.uk/case-studies 8 A rooflight suitable for horizontal installation The Walk on Rooflight from the Rooflight Company is designed for domestic use of flat roof areas whilst affording the benefits of daylighting to the space beneath the roof. The Walk on Rooflight concept is fast growing in popularity alongside the increasing need for maximum space utilisation. A typical installation is where access to a flat roof space is required to enable the area to be used as a roof terrace or garden or simply to allow safe access across the roof area. The Rooflight Company Walk on Rooflight sits flush with the roofing material or decking surface and is available in a range of sizes, colours and glazing options, for example the installation may require an obscured inner leaf to the double glazed maximum unit to provide privacy to and from the space beneath. Discuss your requirements with the Customer Services team and we’ll be happy to provide a Walk on Rooflight to suit your needs. Features Include: • Flush fitting. • Stainless Steel construction for strength. • Range of colour choices. • Powder coated finish for durability. • ‘Fixed Shut’ providing safety and sleek lines. • Built to ISO 9001 in our UK factory. • Clear Float The Walk on Rooflight achieves a whole window u-value (Uw) of 1.3Wm2K in accordance with EN ISO 10077-2:2012. The u-value results are for the window orientated in the vertical pane. • Glazing Loads: 1.4kN concentrated loads and assumed uniform distributed load of 1.5kN/m². • Various surface finishes available(recommended slip resistance for external areas). Residential Property Oxford How to maximise living space is a common challenge for architects, especially in urban areas. The owner of this residential property in Oxford wanted to transform an unusable flat roof area with a domed skylight into an off-bedroom terrace, without reducing natural light ingress to the room below when removing the dome light. The design of the Walk on Rooflight allowed the client to maximise the whole of the roof area as desired. “The Walk on Rooflight was researched and specified by Tom Man from Perioli Man Architects. It was specified by the architect as being the perfect product for what the client was trying to achieve. Dot Matrix Sandblast The technical information and support from the Rooflight Company was a key factor to the success of this project, having never installed a Walk on Rooflight before. They were able to answer all of our questions and queries throughout the project from design to installation to ensure all went smoothly. The client is extremely happy as it has turned out exactly as she had imagined. We will definitely be working with you again on future projects.” Steve - Rayner Ltd (Contractor) The architect specified a Walk on Rooflight with structural measurements of 1148mm x 1148mm with clear glazing. 9 the Walk on Rooflight The Walk on Rooflight 10 Low modulus, neutral cure silicone weather seal - FACTORY FITTED Polyester powder coated stainless steel frame - FACTORY FITTED Packer - SUPPLIED BY OTHERS Decking support angle (use where required) - SUPPLIED BY OTHERS Low modulus, neutral cure silicone thick permieter seal (apply before fitting rooflight to kerb upstand) - SUPPLIED BY OTHERS Decking timber frame - SUPPLIED BY OTHERS Decking - SUPPLIED BY OTHERS External weathered surface - SUPPLIED BY OTHERS Adjustable decking support - SUPPLIED BY OTHERS Roofing boards - SUPPLIED BY OTHERS Plasterboard (12.5mm) - SUPPLIED BY OTHERS Plaster skim (3mm nominal) - SUPPLIED BY OTHERS Roof joists - SUPPLIED BY OTHERS Softwood packers - SUPPLIED BY OTHERS Kerb upstand - SUPPLIED BY OTHERS Coachscrews - FACTORY SUPPLIED Thermoliner - FACTORY FITTED Timber linings - FACTORY FITTED* 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 The Rooflight Company's POLICY IS TO CONTINUOUSLY DEVELOP AND IMPROVE OUR PRODUCTS AND THEREFORE RESERVE THE RIGHT TO MODIFY OR CHANGE PRODUCT DETAILS AT OUR DISCRETION AND WITHOUT PRIOR NOTICE. FOR DOMESTIC LOADING APPLICATIONS ONLY WHERE. > MAXIMUM CONCENTRATED LOAD = 1.4kN. > MAXIMUM UNIFORM DISTRIBUTED LOAD = 1.5kN/m2. THIS DRAWING DOES NOT CONSTITUTE A STRUCTURAL PROPOSAL. SIZING OF STRUCTURAL SUPPORT MEMBERS TO BE PROVIDED BY ROOFLIGHT PURCHASER'S STRUCTURAL ENGINEER. PLEASE NOTE: THE WALK-ON PLATEAU ROOFLIGHT SHOULD BE INSTALLED ONTO A FLAT ROOF CONSTRUCTION THAT HAS SUFFICIENT CONSIDERATION TO ALLOW FOR ADEQUATE DRAINAGE BOTH OFF THE ROOFING STRUCTURE AND THE ROOFLIGHT ITSELF. IF SUFFICIENT DRAINAGE IS NOT PRESENT, WATER POOLING MAY OCCUR, WHICH WILL REQUIRE MORE REGULAR CLEANING OF THE ROOFLIGHT. * THIS ITEM MUST BE PAINTED WITH A TIMBER FINISHING PAINT ONCE THE UNIT IS INSTALLED TO ENSURE LONGEVITY OF THIS COMPONENT UNDERTAKEN BY OTHERS. 33mm triple laminate outer panel, 16mm argon filled cavity, 8.8mm low emmisivity laminated IGU - FACTORY FITTED 1 Item Description 150mm Minimum Kerb Height 108mm 50mm Viewable to Structural CLEAR STRUCTURAL 14 15 16 17 18 19 1 115mm Maximum Kerb Width 57mm 2 3 4 5 6 7 8 13 12 11 10 9 Variable to Client Installation Detail the Walk on Rooflight The Walk on Rooflight Cross Section the Walk on Rooflight The Walk on Rooflight Sizes Walk On Sizes External Width (mm) 814 1114 1414 1514 1714 2214 Structural Kerb Width (mm) 700 1000 1300 1400 1600 2100 Internal Viewable Width (mm) 600 900 1200 1300 1500 2000 WO-01 814 1114 1414 700 1000 1300 WO-07 WO-08 WO-02 WO-09 WO-10 WO-03 WO-11 600 WO-12 900 1200 WO-04 1514 1400 1300 External Width (mm) Structural Kerb Width (mm) Internal Viewable Width (mm) rnal Exte W idth idth ble W a View For more information regarding sizes and installation, contact our technically-trained team on 01993 833108. 11 the Lantern Rooflight the Lantern Rooflight Bespoke Lantern Rooflight, Wiltshire. For the full case study visit: www.therooflightcompany.co.uk/case-studies 12 the Lantern Rooflight A rooflight suitable for horizontal installation. Interior view of a Lantern Rooflight 1200mm x 1500mm. the Lantern Rooflight Lantern Rooflights are used to great effect in many types of buildings particularly Victorian ones, where the shape and proportions fit well with the architecture. Their fine steel edges and traditional appearance ensure that the original lines of the building are not disrupted, and the increase in light they offer is extremely effective. A Lantern Rooflight measuring 1200mm x 1500mm for a residential property, Wiltshire. Residential property, Knightsbridge, London The impact of overhead natural light can turn a normal stairwell into a masterpiece of shadows and tones precisely the result of installing this Lantern (1200mm x 1500mm) into an early Victorian villa in central London. The narrow steel sections maximise light to the stairwell below. In order to blend with the pale yellow interior, the glazing bars and silicone are white, as is the Thermoliner® thermal lining, which ensures condensation control. The silicone and Thermoliner are white to blend with the pale interior on this Lantern Rooflight. ® The Lantern replaced a tired polycarbonate dome yellowed with age. Lantern Rooflight, Calne, Wiltshire Neville Hoyland of Watson Bertram and Fell, Bath, specified this Bespoke Lantern for a new extension to an early Victorian dairy. The client wanted a light and airy room, which is positioned at the south west corner, but did not want a conservatory. The solution was to specify a Lantern Rooflight measuring 1200mm x 2500mm which illuminates the room and enhances the building’s external appearance. A Lantern Rooflight measuring 1200mm x 1500mm for a residential property, Wiltshire. 13 14 External kerb width/length. Internal kerb width/length. Timber lining by contractor. 150m hand winder. (option A or J) shown here will open the rooflight approximately 150mm at the cill. Thermoliner. Thermally-decoupled lining subframe-factory fitted. 12.5 Insect mesh. 150 minimum kerb height recommended. 9mm marine/WBP ply packers on kerb top. 150mm maximum kerb width. This detail shows a ventilated roof cavity with a lead/sheet covering over. Lead roofing. Separating membrane. Ply substrateto lead roof deck. Structure ventilation air path. 25 DO NOT SCALE. IF IN DOUBT ASK. ALL DIMENSIONS IN MILLIMETERS UNLESS STATED OTHERWISE. the Lantern Rooflight The Lantern Rooflight Cross Section (mm) 150 150 150 150 150 150 150 150 150900 150 pl600Access pl900Access pl600x900Access 600 pl600x1200Access pl900x1200Access 150 150 150 150 150 (mm) (mm) (mm) 600 900 1200 1500 900 1200 1200 1500 1500 2000 600 900 1200 1500 600 600 900 900 1200 1500 900 1200 1500 1800 1200 1500 1500 1800 1800 2300 900 1200 1500 1800 900 900 1200 1200 1500 2000 1800 900 1200 1200 1500 1500 900 1200 900 900 1200 The Lantern Rooflight Sizes LT01 1200 1500 600 LT02 600 900 900 1200 1200 900 600 600 900 LT03 (Kg) 39 62 89 121 48 57 69 80 95 135 39 62 900 900 1200 the Lantern Rooflight pl600 pl900 pl1200 pl1500* pl600x900 pl600x1200 pl900x1200 pl900x1500 Internal Kerb pl1200x1500 Width (mm) pl1500x2000* (mm) LT04 *Note: pl1500 rooflights utilise 1 central glazing bar. Ironmongery can be found on p22-23. Note ironmongery required with escape. Plateaus to be installed on a 5º pitch. Open edge must be at lowest point for water drainage/run off. 900 The above dimensions are examples of models which can be achieved. Please contact our Customer Service Department to discuss your requirements on 01993 833143, 833117, 833136. LT05 the Added Security Rooflight 1200 Model pl600 pl900 pl1200 pl1200x600 pl1200x900 pl900x600 1500 Max.Kerb Thickness (mm) Internal Kerb Width (mm) Internal Kerb Length (mm) Max.Ext. Kerb Width (mm) Max.Ext. Kerb Length (mm) 150 150 150 150 150 150 600 900 1200 1200 1200 900 600 900 1200 600 900 600 900 1200 1500 1500 1500 1200 900 1200 1500 900 1200 900 Ke Pla La LT06 Please contact 01993 833143, 833117, 833136 to discuss specification details and options available. Internal Kerb Length (mm) the Walk On Rooflight Please contact 01993 833143, 833117, 833136 to discuss specification details and options available. the Pyramid Rooflight Model PY01 PY02 PY03 PY04 Max.Kerb Internal Kerb Max. Kerb Thickness Thickness (mm) Width (mm) 150 600 150 900 150 1200 Internal Kerb Length (mm) 1500 150 External Kerb Length (mm) Internal Kerb Length (mm) Max.Ext. Kerb Max.Ext. Kerb Rooflight Width (mm) Length (mm) Weight (Kg) 600 900 1200 1500 900 1200 1500 1800 900 1200 1500 1800 Glazing Pitch * (Degrees) 54 Internal Kerb Width 45 87 45 External 127 45Kerb Width 177 45 Kerb Height 150mm min. *Note: Standard pitch is 45º; A 10º - 45º glazing pitch can be specified on a non standard Rooflight. Please contact Customer Service on 01993 833143, 833117, 833136. the Lantern Rooflight Existing Flat Roof Model Max.Kerb Internal Kerb Thickness (mm) Width (mm) Internal Kerb Length (mm) Max.Ext.Kerb Width (mm) Max.Ext. Kerb Rooflight Length (mm) Weight (Kg) Glazing Pitch* (degrees) LT01 LT02 LT03 LT04 LT05 LT06 150 150 150 150 150 150 600 600 900 900 1200 1500 1200 1500 1500 1800 1800 2300 900 900 1200 1200 1500 1800 45 45 45 45 45 45 900 1200 1200 1500 1500 2000 *Note: Standard pitch is 45º. A 10º - 45º glazing pitch can be specified on a non standard Rooflight. Please contact Customer Service on 01993 833143, 833117, 833136. 75 86 112 127 162 226 15 the Pyramid Rooflight the Pyramid Rooflight The Pyramid Rooflight, East Sussex. For the full case study visit: www.therooflightcompany.co.uk/case-studies 16 The Pyramid Rooflight A rooflight suitable for horizontal installation. The Pyramid shape is incorporated in many project designs today for both traditional and modern buildings. The Pyramid Rooflight benefits from the same weathering and design characteristics featured in page 6. The finely detailed design along with the Pyramid’s weathering prospects are cited as reasons for specification. Commercial Premises, Tewkesbury Black Pyramid Rooflights provide light and ventilation in an extension to a Tudor building. Mansion House, Wiltshire Pyramid and Lantern Rooflights were specified to provide light and ventilation to a large flat roof extension to a mansion house in Wiltshire. The architect wanted to maximise light to the new accommodation and chose four Pyramid 1200mm and two Lanterns measuring 1200mm x 1500mm. The fine steel lines ensure maximum light penetration to the spaces below, while offering a pleasing visual appearance to the roof. A combination of Pyramids and Lanterns provide huge amounts of light while being aesthetically pleasing. Extension to church, Ringmer, East Sussex A Pyramid Rooflight measuring 1200mm x 1200mm placed deep in a leaded valley between clay-tiled pitched roof sections to an extension of a church. The Pyramid Rooflight cannot be seen externally, but floods a lobby between the old church and new community rooms below with light – introducing an element of surprise into an area with no apparent natural light source. The clear glass of the Pyramid Rooflight assists light penetration, where an obscured or polycarbonate unit would not let in sufficient light to give this surprise effect. A Conservation Rooflight® and a Pyramid Rooflight. 17 the Pyramid Rooflight Pyramid Rooflights were specified for an extension to commercial premises in the historic High Street of Tewkesbury. As a large number of the original Tudor buildings overlook the property, the architect wanted to achieve an appearance that was aesthetically pleasing, while introducing much-needed ventilation. 18 External kerb width/length. Internal kerb width/length. Timber lining by contractor. 150m hand winder. (option A or J) shown here will open the rooflight approximately 150mm at the cill. Thermoliner. Thermally-decoupled lining subframe-factory fitted. 12.5 Insect mesh. 150 minimum kerb height recommended. 9mm marine/WBP ply packers on kerb top. 150mm maximum kerb width. This detail shows a ventilated roof cavity with a lead/sheet covering over. Lead roofing. Separating membrane. Ply substrateto lead roof deck. Structure ventilation air path. 25 DO NOT SCALE. IF IN DOUBT ASK. ALL DIMENSIONS IN MILLIMETERS UNLESS STATED OTHERWISE. the Pyramid Rooflight The Pyramid Rooflight Cross Section The Pyramid Rooflight Sizes Internal Kerb Width (mm) 600 900 1200 1500 the Plateau Rooflight PY01 Model Max.Kerb Thickness (mm) 600 900 1200 pl600Access pl900Access pl600x900Access pl600x1200Access pl900x1200Access Internal Kerb Length (mm) 150 150 150 150 150 150 150 150 150 150 600 900 1200 1500 900 1200 1200 1500 1500 2000 900 1200 1500 600 600 900 900 1200 1500 150 150 150 150 150 600 900 900 1200 1200 PY02600 Max.Ext. Kerb Width (mm) 900 1200 1500 1800 1200 1500 1500 PY03 1800 1800 2300 900 1200 1200 1500 1500 600 900 600 600 900 Max.Ext. Kerb Length (mm) Rooflight Weight (Kg) 900 1200 1500 1800 900 900 1200 1200 1500 1800 39 62 89 121 48 57 69 80 95 135 900 1200 900 900 1200 39 62 900 900 1200 PY04 the Pyramid Rooflight pl600 pl900 pl1200 pl1500* pl600x900 pl600x1200 pl900x1200 pl900x1500 pl1200x1500 pl1500x2000* Internal Kerb Width (mm) *Note: pl1500 rooflights utilise 1 central glazing bar. Ironmongery can be found on p22-23. Note ironmongery required with escape. Plateaus to be installed on a 5º pitch. Open edge must be at lowest point for water drainage/run off. 1500 The above dimensions are examples of models which can be achieved. Please contact our Customer Service Department to discuss your requirements on 01993 833143, 833117, 833136. the Added Security Rooflight Internal Kerb Model Length (mm) pl600 pl900 pl1200 pl1200x600 pl1200x900 pl900x600 Max.Kerb Thickness (mm) Internal Kerb Width (mm) 150 600 150 900 150 1200 Max. 150 Kerb Thickness 1200 150 1200 150 900 Ke Pl La Standard glazing pitch is 45º Internal Kerb Length (mm) Max.Ext. Kerb Width (mm) Max.Ext. Kerb Length (mm) 600 900 1200 600 900 600 900 1200 1500 1500 1500 1200 900 1200 1500 900 1200 900 Internal Kerb Width External Kerb Width Please contact 01993 833143, Internal 833117, 833136 to discuss specification details and options available. Kerb Height 150mm min. Kerb Le Externa ngth (mm l Kerb L ) the Walk On Rooflight ength (m m) Existing Flat Roof Please contact 01993 833143, 833117, 833136 to discuss specification details and options available. the Pyramid Rooflight Model Max.Kerb Internal Kerb Thickness (mm) Width (mm) Internal Kerb Length (mm) Max.Ext. Kerb Max.Ext. Kerb Rooflight Width (mm) Length (mm) Weight (Kg) Glazing Pitch * (Degrees) PY01 PY02 PY03 PY04 150 150 150 150 600 900 1200 1500 900 1200 1500 1800 45 45 45 45 600 900 1200 1500 900 1200 1500 1800 54 87 127 177 *Note: Standard pitch is 45º; A 10º - 45º glazing pitch can be specified on a non standard Rooflight. Please contact Customer Service on 01993 833143, 833117, 833136. the Lantern Rooflight 19 The Secured by Design Rooflight the Secured by Design Rooflight The Secured by Design Rooflight. For more information visit: www.therooflightcompany.co.uk/case-studies 20 The Secured by Design Rooflight A rooflight suitable for roofs between 3° and 5°. For buildings where security is paramount, the Secured by Design Rooflight is the first rooflight to be Secured by Design accredited to Loss Prevention Standard 1175-6 Level 3. Features include: • • • • • • Standard Double glazing includes outer pane conforming to CAT P6B BSEN356 combined with a low u-value Glazing options include obscure glass Fixed shut stainless steel frame Maximum security and anti-glare glazing options Optional coated stainless intruder security bars Available in white, black, light and dark grey or any RAL colour. The Keep The architects wanted to design a modern building which combined latest technologies. As well as high security elements such as solar panels and solar heating, thick walls and a biomass boiler were used so the so that the final building would be certified as a BREEAM Excellent Building. Due to the nature of the content held within the building, the architect wanted to specify rooflights which would provide maximum security to the building. The Rooflight Company were the only manufacturer manufacturer that Atkins Architects could find which offers Secured by Design. “Kier worked with the rooflight company for over two years on this project as they were able to meet the specific brief of high security rooflights required. They offered a rooflight solution which matched the security levels needed for the building which no other manufacturer can supply.” the Secured by Design Rooflight The Keep is a new-build historical research centre in Falmer, Brighton. The building has been designed to be used by the general public or educational groups within the community. The project started in 2011 and opened in June 2013. Kier, Main Contractors A total of ten Secured by Design Rooflights were supplied to this scheme, measuring 1225mm x 1225mm and in jet black. 21 22 Plaster board ceiling Ceiling support battens Concrete roof deck Screed (If not cut to falls) Insulation Roof covering (30N/mm (C20/25) Concrete) 2 Reinforced, poured concrete kerb Vapour control layer (Dressed into Thermoliner®) Silicone bead (Low modulus neutral cure) A A SCALE 1 : 5 DETAIL B the Secured by Design Rooflight B Batten Plaster board Insulation Please Note: This is a diagrammatical representation. Some components have been increased in scale for clarity.This is the recommended installation into a concrete slab roof, the suitability for the specific application will need to be confirmed by the project engineer. Timber batten (securely fixed over rooflight fixing points) M10 10L Product Code: 44-105 (Install as per manufactures Details)Utilise all fixing points. Fixings supplied with Rooflight. Rawlbolt ® Shield Anchor Rooflight fixing point Factory fitted) Thermoliner ® (Thermal-decoupled lining. Secured by Design Plateau SCALE 1 : 20 SECTION A-A The Secured by Design Rooflight Cross Section The Added Secured bySizes Design Rooflight Sizes Security and Prices Internal Kerb Width (mm) 600 900 1400 1500 2000 Code SBD01 600 1200 Added SBD07 1 SBD08 2 3 SBD02 4 900 1 2 3 4 5 6 7 8 9 10 SBD09 SBD10 5 7 SBD11 SBD03 SBD07 SBD08 SBD02 SBD09 SBD03 SBD10 SBD11 Bespoke 1400 Bespoke 2000x14 8 6 1200 SBD01 Code Bespoke 1400 Added Security Features 9 1400 Glass Options P6B P7B P8B SBD01 600x600mm £1001 £1030 £1060 SBD07 900x600mm £1173 £1215 SBD08 1200x600mm £1466 SBD02 900x900mm SBD09 SBD03 SBD08 SBD02 SBD09 SBD03 SBD10 Se Bars £45 £212 £298 £1256 £45 £249 £298 SBD L2 PL0 £1520 £1575 £45 £292 £298 SBD L2 PL0 £1666 £1727 £1789 £45 £286 £327 SBD L2 PL0 1200x900mm £1900 £1981 £2061 £45 £324 £327 SBD L2 PL0 1200x1200mm £2409 £2514 £2621 £45 £362 £334 SBD L2 PL0 1500x900mm POA POA £45 POA POA SBD L2 PL1 SBD11 1500x1200mm POA POA £45 POA POA SBD L2 PL1 Bespoke 1400 1400x1400mm POA POA POA £45 POA POA L2 Bespoke Bespoke 2000x1400 2000x1400mm POA POA POA £45 POA POA L2 Bespoke 20 id W idt W b er lK na POA te r Le Existing Flat Roof SBD11L2 Kerb Height 150mm min. Bespoke 1400 Secured by Design Accredited Code Security Hinges Cover Bars SBD01 £47 £222 £313 SBD L2 01 £1318 SBD L3 01 SBD07 £47 £262 £298 SBD L2 07 £1660 L3 Not available in this size SBD08 £47 £307 £313 SBD L2 08 £2106 L3 Not available in this size SBD02 £47 £301 £343 SBD L2 02 £2460 L3 Not available in this size SBD09 £47 £340 £343 SBD L2 09 £2995 L3 Not available in this size SBD03 £47 £380 £351 SBD L2 03 £3970 L3 Not available in this size SBD10 £47 POA POA SBD L2 10 £3555 L3 Not available in this size SBD11 £47 POA POA SBD L2 11 £4880 L3 Not available in this size Bespoke 1400 £47 POA POA L2 Bespoke 1400 £5141 L3 Not available in this size Bespoke 2000x1400 £47 POA POA L2 Bespoke 2000x1400 £7124 L3 Not available in this size L2 Approved Ap SBD L2 PL0 Bespoke 2000x14 h rb Ke al th ng Le POA Ex rb Ke erb lK rn al ern Int na ter SBD10 te Max. Kerb Thickness Ex 1 2 3 4 5 6 7 8 9 10 SBD07 Cover th Size (w x l) SBD01 the Secured by Design Rooflight Code Additional Security Options oke 2000x1400 Additional Security Options 1 2 3 4 5 6 7 8 9 10 th ng Internal Kerb Length (mm) 1 2 3 4 5 6 7 8 9 10 10 10 In 2000 Bespoke 2000x1400 L3 Approved £1590 23 the Added Security Rooflight the Added Security Rooflight The Added Security Rooflight, St Peter’s School in Gloucestershire. For the full case study visit: www.therooflightcompany.co.uk/case-studies 24 The Added Security Rooflight A rooflight suitable for roofs between 3° and 5°. For buildings where security is paramount but where the Secured by Design accreditation is not necessary , the Added Security Rooflight is available with a choice of specification. Features include: • • • • • • • • A flexible menu of Added Security options to meet the specific needs of your project including openable rooflights, combining aesthetics and security Glazing options include CAT P6B BS EN 356 with bonded interlayer, reducing risk of intrusion Tamper proof hinges and security bars Optional protective glazing perimeter guard to increase security Bespoke design service readily available Linked sensors to fire alarm systems Low profile casement standing only 95mm above kerb height Available in white, black, light and dark grey or any RAL colour. St Peter’s Catholic Primary School is a newbuild project in Gloucester. The original school has been demolished to make way for a modern building that is light and airy with open spaces replacing cramped, dark corridors and internal classrooms being joined to outdoor learning areas. Each corridor space is flooded with natural light and ventilation through a total of 17 openable Plateau Rooflights. Two of these rooflights are linked together to create a large expanse of light, and one rooflight is a large bespoke array spanning 12m long by 1m wide. “We put a lot of investment into the roof as the client wanted to maximise commodities such as natural light and air, and by using large rooflights this is achieved. It is widely accepted that concentration levels are improved when light and fresh air is available and this is vital in a school environment. The Rooflight Company designed a rooflight that was the Added Security Rooflight St Peter’s Catholic Primary School 12m long and 1m wide – this is not something we could achieve elsewhere. We also wanted to open the rooflights as wide as possible and the system provided allowed us to do this. The Rooflight Company enabled us to have the added security features such as tamper proof hinges without having bars across the glazing which we felt would compromise aesthetics, light and shadow.” Architect: Rob Tadman – Fielden Clegg Bradley Studios Schools are vulnerable buildings and the local Crime Prevention Officer was involved in the project, wanting to ensure that added security methods were put in place to prevent unauthorised access via the roof. In addition, each rooflight has been fitted with tamper proof fittings. The rooflights are also connected to the building management system with rain sensors, ensuring that the rooflights automatically close in bad weather conditions. 25 26 9 12 6 10 7 3 12c 14 4 2c 2b 1e 4b Structural kerb length of 41.50 (from inside face able) structural kerb to view 6b 5 1b 2d 1d 9b Structural kerb length of 41.50 (from inside face able) structural kerb to view 6b 5 1c 1e 1d 2b 2c 3 14 150 Minimum kerb height 4 12c 12 6 10 7 9 6b 2c 4 14 12b 9b 3 11 6 10 7 9 Please Note: These sectional details are provided as an installation suggestion. Due to the differing nature of installations we strongly advise you to consult 'Rolled Lead Sheet - The Complete Manual' published by The Lead Sheet Association (www.leadsheet.co.uk) and your roof window installer to verify fitness for purpose. This drawing does not constitute a structural proposal. Sufficiency of structural supports to be checked by roof window purchaser's structural consultant. 2 Key: 1. The Plateau Rooflight, with Manual Opening Option 1b fixed to structural kerb 2c using coach bolts fixed through fixing lugs 1c around the perimeter of the roof window. 2. Structural rafter support at jamb and structural trimmer support at head and cill 2b. Structural kerb upstand 2c to be a minimum of 150mm high. Ironmongery supportive packer 2d at the cill, fitted around the fixing lugs. 0 100 200 300 3. WBP Plywood roof deck. 4. Insulation fitted above structural supports and around the perimeter of the kerb upstand 4b. Scale - mm 5. Timber reveal to align with the roof window linings 1d to provide 'frameless' internal appearance. If the roof window linings 1 15 4b 13 are not already factory painted, 1d MUST BE PAINTED with a timber finishing paint once the roof window is installed to ensure longevity of this component. 1d 6. Plasterboard lining with plasterboard stop 6b to protect the corner. Plasterboard fitted behind the thermoliner of the roof window 1e. 7. Plaster skim. 1e 12 8. Angled packer to deflect water around the head of the kerb upstand and prevent water pooling. 9. Structural boards installed above insulation and around the perimeter of the kerb upstand 9b. 5 10. Underlay. 11. Softwood roofing battens. 12. Lead sheet roofing. Rolls 12b to run with the angle of Roof pitch, and splay 12c at least 150mm from the 41.50 (From inside face of structural kerb to viewable) kerb upstand to allow water to flow freely around the perimeter and prevent water pooling. Run the main sheet up the kerb upstand. Viewable width 13. WBP plywood packers. Structural width 14. Vapour barrier 150 maximum 15. Perimeter silicone seal. 41.50 150 Maximum kerb width Viewable length Seal perimeter of roof kerb width Viewable length 41.50 window 1 JUST PRIOR TO 3 - 5 Minimum fall to installation, using a thick prevent water pooling 9b 13 15 8 continuous bead of low 13 15 modulus neutral cure 1 1 silicone sealant. 4b the Added Security Rooflight The Added Security Rooflight Cross Section The Added Security Rooflight Sizes Added Security Sizes and Prices Internal Kerb Width (mm) 600 900 SBD01 SBD07 1 600 1200 2 1500 2000 SBD08 1 2 3 4 5 6 7 8 9 10 3 SBD02 4 900 1400 Added Sec SBD09 SBD10 5 7 SBD11 SBD03 S SBD01 6 SBD07 9 SBD08 1 SBD02 9 SBD09 1 SBD03 1 SBD10 1 SBD11 1 Bespoke 1400 1 Bespoke 2000x1400 2 8 6 1200 Code Ad S H Code Bespoke 1400 Bespoke 2000x1400 10 Internal Kerb Length (mm) Max. Kerb Thickness SBD01 SBD07 SBD08 SBD02 the Added Security Rooflight 9 1400 1 2 3 4 5 6 7 8 9 10 SBD09 SBD03 SBD10 SBD11 Bespoke 1400 Bespoke 2000x1400 h rb idt Ke W al rn er b te In th erb ng lK Le na rb ter Ke W id al th ern Int Ex Ex te r th na ng lK Le Added Security Features Existing Flat Roof Kerb Height 150mm min. Glass Options 1 2 3 4 5 6 7 8 9 10 Additional Security Options Code Size (w x l) P6B P7B P8B SBD01 600x600mm £1001 £1030 £1060 SBD07 900x600mm £1173 £1215 SBD08 1200x600mm £1466 SBD02 900x900mm SBD09 Cover Bars £45 £212 £298 £1256 £45 £249 £298 £1520 £1575 £45 £292 £298 £1666 £1727 £1789 £45 £286 £327 1200x900mm £1900 £1981 £2061 £45 £324 £327 SBD03 1200x1200mm £2409 £2514 £2621 £45 £362 £334 SBD10 1500x900mm POA POA POA £45 POA POA SBD11 1500x1200mm POA POA POA £45 POA POA Bespoke 1400 1400x1400mm POA POA POA £45 POA POA Bespoke 2000x1400 2000x1400mm POA POA POA £45 POA 27 POA the Polyedge Rooflight the Polyedge Rooflight 28 The Polyedge Rooflight, Buckinghamshire. For more information visit: www.therooflightcompany.co.uk/case-studies Model Max.Kerb Thickness (mm) Internal Kerb Width (mm) Internal Kerb Length (mm) Max.Ext. Kerb Width (mm) Max.Ext. Kerb Length (mm) pl600 pl900 pl1200 pl1200x600 pl1200x900 pl900x600 150 150 150 150 150 150 600 900 1200 1200 1200 900 600 900 1200 600 900 600 900 1200 1500 1500 1500 1200 900 1200 1500 900 1200 900 The Polyedge Rooflight A rooflight suitable for horizontal installation. Plateau, Pyramid and Lantern Rooflights Ke 15 Please contact 01993 833143, 833117, 833136 to discuss specification details and options available. The Polyedge Rooflight is typically specified in classic and historic buildings but its sleek, steel lines are equally suited Internal Kerb Width tothe modern architecture. The Hexagonal and Octagonal Polyedge Rooflights have been used to great effect on the case Walk On Rooflight Please contact 01993 833143, 833117, 833136 to discuss specification details and options available. studies below. They benefit from the technical specification featured on page 6. the Pyramid Rooflight Maximum External Kerb Width Stowe House, Buckinghamshire, Purcell Glazing Miller Tritton Model Max.Kerb Internal Kerb Thickness (mm) Width (mm) Internal Kerb Length (mm) Max.Ext. Kerb Max.Ext. Kerb Rooflight Width (mm) Length (mm) Weight (Kg) PY01 PY02 PY03 PY04 150 150 150 150 600 900 1200 1500 900 1200 1500 1800 900 1200 1500 1800 Model Max.Kerb Internal Kerb Thickness (mm) Width (mm) Internal Kerb Length (mm) Max.Ext.Kerb Width (mm) Max.Ext. Kerb Rooflight Length (mm) Weight (Kg) Glazing Max. Ext. Kerb Pitch* Width:(degrees) 2300mm LT01 LT02 LT03 LT04 LT05 LT06 150 150 150 150 150 150 600 600 900 900 1200 1500 1200 1500 1500 1800 1800 2300 900 900 1200 1200 1500 1800 45 600 900 1200 1500 Existi Pitch * (Degrees) Hexagonal Minimum 54 Internal Width (mm) 45 Octagonal Minimum Internal Width (mm) The87 Rooflight Company provided twelve rooflights 45 oct900 hex900 127 45 including this Octagon Rooflight for the extensive 177 45 Maximum Internal Width (mm) renovation of hex2000 Stowe House in Buckinghamshire. *Note: Standard pitch is 45º; A 10º - 45º glazing pitch can be specified Maximum Internal Width (mm) Max. Ext. Kerb on a non standard Rooflight. Please contact Customer Service on 01993 833143, 833117, 833136. This 18th Century building, home toMax.aExt.boarding school, Kerb Width: 1200mm oct2000 Width: 1200mm is widely recognised as one of a hundred endangered Max. Kerb Thickness the Lantern Rooflight sites of significance worldwide. 900 1200 1200 1500 1500 2000 Owing to its unique nature, and because Stowe House is 75 45 Max. Ext. Kerb currently listed English 2300mm The above dimensions 86 are examples 45 on their buildings at risk register,Width: of models which can be achieved. 112 45 Heritage worked in close consultation on the project. 45 be specified *Note: A 10º 127 - 45º glazing pitch can Please contact our Bespoke Department on 01993 833143 / 833117 162 45 for information on prices for this product. Note: This framing is for hex. rooflights only al Ke rb Le Kerb Height 150mm min. gth en bL th er ng lK 1200 2300 1200 2300 rn 20 degrees 20 degrees 20 degrees 20 degrees 900 2000 900 2000 te 150 150 150 150 Max.Kerb Thickness na hex900 (min) hex2000 (max) oct900 (min) oct2000 (max) Max. Kerb Thickness In Glazing Pitch (degrees) ter Max.Kerb Internal Kerb Max.Ext.Kerb Thickness (mm) Width (mm) Width (mm) Ex Model Exi Internal Kerb Width the Polyedge Rooflight 226 Maximum External Kerb Width Ventilation is easily achieved by means of an electric *Note: Standard pitch is 45º. A 10º - 45º glazing pitch can be specified on a non standard Rooflight. actuator. Please contact Customer Service on 01993 833143, 833117, 833136. Note: The above dimensions are examples of models which can be achieved. Please contact Specials Dept on 01993 833143, 833117, 833136. Hexagonal Octagonal Minimum Internal Width (mm) Minimum Internal Width (mm) hex900 oct900 Max. Ext. Kerb Width: 1200mm hex2000 the Polyedge Rooflight Maximum Internal Width (mm) Maximum Internal Width (mm) Max. Ext. Kerb Width: 1200mm oct2000 Max. Ext. Kerb Width: 2300mm The above dimensions are examples of models which can be achieved. *Note: A 10º - 45º glazing pitch can be specified Please contact our Bespoke Department on 01993 833143 / 833117 for information on prices for this product. Max. Ext. Kerb Width: 2300mm 29 Accessories Accessories To view the accessories on our website visit www.therooflightcompany.co.uk/accessories 30 Ironmongery Option C Chrome pole winder with option F pole. Option W Anodised hand winder. Pole winders for rooflights out of reach Hand winders for rooflights within reach Option K: Option A: Brass telescopic Brass telescopic pole winder 150mm hand winder 150mm Option D: Option E: Brass telescopic Brass telescopic pole winder 300mm hand winder 300mm Option L: Option J: Chrome plated telescopic Chrome plated telescopic pole winder 150mm hand winder 150mm Option C: Option B: Chrome plated telescopic Chrome plated telescopic pole winder 300mm hand winder 300mm Option M: Option W: Anodised aluminium Anodised aluminium pole winder 300mm wheel on chrome plated hand winder 150mm Option T: Anodised aluminium Option Y: pole winder 500mm Black wheel on brass hand winder 150mm Accessories Option P: Cord operated gear 300mm Note: Option U and S from previous brochures are no longer available. 31 Motors Electric chain actuators Electric linear actuators Poles - required to operate pole winders Option F: Aluminium 1.0m length MAC MOTOR AU-Max Option MAC MOTOR : Option AU-Max Electric linear actuator 230v, 24v 150mm only 230v 300mm & 500mm Electric rack actuators SUPERMASTER MOTOR Option SUPERMASTER MOTOR: 230v, 24v 420 - 600mm Option Rack Electric linear actuator 230v, Aluminium 2.0m length Option I: Aluminium 1.75-3.0m telescopic actuator 230v, 24v 180mm Please discuss your specific 230v, 24v 180mm Service. Rain, Temperature and * Please note a coupling request. Please discuss your specific these motors Smoke sensors are available on Option H: Option Double Rack* Electric linear Option Dual Rack* requirements with Customer Aluminium 1.5m length 24v 180-750mm The selection of actuator depends on the rooflight size and application. Option G: Electric linear actuator rod is required to operate requirements with Customer Service. An on/off switch is required for these Accessories products. Please ask for details A Rack Motor on a triangular rooflight. 32 Option R with two Options M’s. A KA66 motor on a flat rooflight Motor Suitability The Lantern Rooflight Model MAC Supermaster Dual Rack Double Rack 230v/24v 230v/24v 230v/24v 150mm only 420/600mm 180mm 180mm • • 230v/24v LT01 LT02 • LT03 • LT04 • LT05 • LT06 • The Pyramid Rooflight Model KA34-350 24v 350mm MAX 230v 300mm PY01 PY02 PY03 PY04 Supermaster 230v/24v 420/600mm • Rack 230v/24v 180mm • • Double Rack 230v/24v 180mm • The Added Security Rooflight PL01 PL02 PL03 PY08 PL09 PL10 PL11 KA 34 -350 24v 350mm See KA Specific Chart Below. The Added Security Rooflight MAX 230v 300mm Rack 230v / 24v 180mm • • • • • • • • The Added Security Rooflight KA Specific Options The Added Security Rooflight PL01 PL02 PL03 PY08 PL09 PL10 PL11 KA 34 (350mm stroke 300N) (24V) KA 54 (350mm stroke 500N) (24V) • • • • • • • KA 34-K (350mm stroke 300N) (230V) • • • KA 54-K (350mm stroke 500N) (230V) • • • 33 The Rooflight Company’s Project Portfolio Our rooflights help architects create beautifully designed naturally lit environments. With nine aesthetically-pleasing rooflight ranges for both pitched and flat roof applications and an unrivalled bespoke design service, we are able to offer a solution to meet your requirements. 34 The Public, West Bromwich. Will Alsop Architects specified Bespoke Triangular Rooflights. The Roundhouse, Derby. Maber Architects specified Bespoke Rooflight, Type A-Linked. Week Farm, Devon. The Nicholas Dean Practice Specified a large Bespoke Conservation Rooflight®. Castle Drogo, Devon. The Harrison Sutton Partnership specified a series of 900mm x 900mm Rooflights. York Way, London. McDonnell Associates specified a Bespoke Plateau measuring 600mm x 1800mm. Yang Sing Hotel, Manchester. Roberta Fulford specified a series of Bespoke Conservation Rooflights® and Studio Rooflights. Our ranges cover both traditional and contemporary styles and suit all building types, from residential to commercial to public. This portfolio demonstrates just a few case studies worked on to date. For more information visit www.therooflightcompany.co.uk/case-studies. Broadclyst School, Devon. NPS South West specified neo™ Rooflights. East Meon, Hampshire. The Artists Studio specified this large Bespoke Rooflight. Residence, Kent. The client specified a series of neo™ Rooflights. Somerset House, London. TGB Consult specified forty Bespoke Conservation Rooflights®. Clay Field, Suffolk. Riches Hawley Mikhail Architects specified these Bespoke neo™ Steel Rooflights for this RIBA award-winning housing scheme. Residence, Calne, Wiltshire. Watson, Bertram & Fell Architects specified this Bespoke 1.25m x 1.25m Lantern. 35 Wychwood Business Centre Milton Road Shipton-under-Wychwood OX7 6XU Tel: 01993 833108 Fax: 01993 831066 email: info@therooflightcompany.co.uk www.therooflightcompany.co.uk Disclaimer Images used in this Rooflight brochure are used for illustrative purposes only. All prices are correct at time of going to press. Due to occasional changes in product specification and material prices always check with the Rooflight Company Customer Services Department on 01993 833108 or online at www.therooflightcompany.co.uk for current prices prior to placing your order. 36 Designed and assembled in the UK.
Similar documents
Roof Window Brochure - The rooflight Company
Featuring a sleek, contemporary design and flush edge-to-edge glazing, the neo™ specified by Jamie Falla offers a roof window that combines unique properties with a frameless, minimalist appearance...
More information