PRODUCT CATALOGUE 2014
SYSTEMS FOR LOCAL EXHAUST VENTILATION - FANS- ATEX - AUTOMATICS
HIGH VACUUM - EXTRACTION ARMS - FILTERS - WELDING BOOTHS - HOSES
CLEAN AIR - PURE SENSE
Geovent 2014
www.geovent.com
Clean air - Pure sense
GEOVENT A/S is a dynamic company specialising in
development and production of components and
systems for advanced industrial ventilation
Since 1968 we have earned our reputation as being
pioneers in this field.
GEOVENT manufacture local exhaust ventilation and
process extraction for industy, defence, power plants,
technical schools, laboratories, off-shore, fire- and
emergency departments and auto repair shops.
All our products live up to statutory requirements
for effective and environmentally safe extraction.
We focus on our customers’ demands for functional
and effective ventilation.
GEOVENT offer fast delivery of both smaller and
larger complete ventilation solutions.
To be able to do this we keep stock of a wide ranges
of pre produced components and have a versatile
and modern factory.
We take pride in a dedicated staff of competent and
experienced employees who know it is important to
satisfy our cumstomers and to meet the deadline.
Our poducts are sold via professional distributors in
many countries.
Table of Content
Exhaust Extraction
Hose reels
Channel Duct
Spring Balance
Garland Rail
Extraction for emergency vehicles
Nozzles
High Vacuum
2
7
13
14
15
16
Extraction Arms
High Vacuum Unit - HVU
HVU Lite / HVU
HVU Data and Pressure Drop Curves
HVU IT / HVU Solo
Filter Cyclone and controls for HVU
Accessories for High Vacuum
70
71
72
74
75
76
ATEX
ATEX Fans - LSX/MSX - LEX/MEX
ATEX Extraction Arms
ATEX Filters and High Vacuum
82
83
86
87
ATEX
WING arm
Compact arm
ASA arm
Flexi arm
Miniarm
23
24
25
26
30
About Geovent Industrial Filters
Oil Mist Filters
Filters for dust, welding and more
Geofilter GFB
Filter media
Multi Coupling Diagram for GFB Filter
34
35
36
39
41
42
Fans
LSFG/MSFG
LSKG/MSKG
LEF/MEF 250-630
Sound boxes for fans
Accessories for fans
ESV Energy saving fan
Plastic Fans
MSQ and MHF Fans
Portable Fans
44
46
46
48
53
54
56
58
60
61
Filters
Welding Booths
Fans
Welding Booths
Welding Tables / Rear Extraction panels
Smoking Cabin
Extraction Panels
Spray Booth
88
92
92
92
92
Air Handling Units - GRTU
Automatics
Automatics for fans
Frequency Inverters
Multibox II
Wiring Diagram
Galvanised Roof Top Unit
94
Hoses and accessories
Hoses
Ducts and Bends
Coonectors, Dampers and more
97
101
102
Sales- and delivery terms
62
64
65
66
Sales and delivery terms
Guide for point extraction.
103
104
H oHs eo se
R e eRl eel
L X /LFXB/ F B
Geovents hose reel systems are available with either
manual or remote controlled electrical winch.
On all models the outlet to duct is ø160mm.
Our hose reels are available with different accessories,
such as direct mounted fan, automatic start/stop of
fan and more.
2
Over the years Geovent has built a
considerable know-how in the field of
repair shop health and safety.
Shown in the photos are results of complete
extraction installations in auto repair shops.
Among other things Geovent has supplied
hose reels for exhaust extraction, general
ventilation and welding extraction.
The result is a safer working environment for
mechanics and leaves the customers with an
impression of a professional and well run
repair shop.
3
Hose Reel LX
Art. No.
Hose Reel electric winch and wireless
remote control. For ø160mm nipple
and 1x 230V.
With hose but without nozzle.
Description
04-590
Hose reel 750LX-05-080
04-591
Hose reel 750LX-07-080
04-592
Hose reel 750LX-10-080
04-593
Hose reel 750LX-05-100
04-594
Hose reel 750LX-07-100
04-595
Hose reel 950LX-10-100
04-596
Hose reel 750LX-05-125
04-597
Hose reel 950LX-07-125
04-598
Hose reel 950LX-10-125
04-599
Hose reel 750LX-05-150
04-600
Hose reel 950LX-07-150
04-601
Hose reel 950LX-10-150
04-602
Hose reel 950LX-05-200
04-603
Hose reel 950LX-07-200
LX-Hose Reel without hose
LX-750
Hose reel LX-750 without hose
LX-950
Hose reel LX-950 without hose
LX-1250
Hose reel LX-1250 without hose
To be combined with exhaust hose.
Hose Reel FB
Art. No.
Hose Reel with spring winch.
For ø160mm nipple. With hose.
Without nozzle.
Description
04-550
Hose reel 450FB-05-080
04-580
Hose reel 450FB-07-080
04-551
Hose reel 750FB-10-080
04-552
Hose reel 450FB-05-100
04-581
Hose reel 750FB-07-100
04-553
Hose reel 750FB-10-100
04-554
Hose reel 750FB-05-125
04-582
Hose reel 750FB-07-125
04-555
Hose reel 950FB-10-125
04-556
Hose reel 750FB-05-150
04-583
Hose reel 750FB-07-150
04-557
Hose reel 950FB-10-150
By default all FB Hose Reel have hose stop included.
For other combinations please enquire.
Hose Reel 750FB-10-080
4
Legend
Hose diameter
Hose length
Type-Description
Drum width
Note:
As the construction of the FB-Hose Reel requires a part of the hose to be
contained within the drum, the effective length of the hose will be
shortend by the with of the Hose Reel.
Example:
A 750FB-10-125 has an effective hose length of: 10m - 750mm = 9,25m.
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Accessories for Hose Reel type LX and FB
Art. No.
Description
04-293
Switch for automatic start/stop of the fan or damper activation.
Accessories for Hose Reel type LX
Art. No.
Description
04-621
Remote control for Hose reel type LX - please specify frequency.
Fan MSQ for direct mounting on the side of the Hose Reel.
See Fans section of this catalogue
Pressure
drop
[Pa]
7,5 m
10 m
5m
Ø80 mm
Ø80 mm
6.000
10 m 7,5 m
5m
Ø100 mm
Ø100 mm
5.000
10 m
Ø125 mm
4.000
7,5 m
Ø125 mm
5m
Ø125 mm
3.000
10 m
Ø150 mm
2.000
7,5 m
5m
Ø150 mm
1.000
Airflow
[m3/h]
200
400
600
800
1.000
1.200
1.400
1.600
1.800
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
5
Dimensions- Hose Reel
LX
FB
C
750
950
1250
450
750
950
A
860
1060
1360
621
921
1121
B*
532
532
532
280
280
280
* The depicted Hose Reel is an FB-Reel. Console and
mounting bracket differ from that of the LX-Reel.
Outer measurements are the same, however.
Installation examples- Hose Reels
Hose Reel LX
Hose Reel FB
A
B
C
D
E
F
G
H
I
6
A: Outlet with jet hood
B: Outlet flange
C: Fan MSFG
D: Wall mounting bracket
E: Start/stop control LWS
F: Fast Action Motor
Damper ø160
G: Hose Reel LX
H: Radio Remote Control
I: Rubber Nozzle
Optional:
Start/stop switch for fan and
open/close motor damper.
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
hannel
ChaC
nn
e l D u c t D uct
To the operator, the Channel duct ensures flexibility
within a large working area. The Channel duct is most
suitable in medium-sized and large garages, where
several working areas may share one or several trolleys
or in larger garages with a flow of cars, like
in car inspection garages.
A large selection of accessories is available for the
Channel duct system, facilitating the use of the system,
such as:
•
electric, remote controlled forward and return
movement,
•
compressed air nozzle for automatic uncoupling
from the exhaust pipe
•
automatic start/stop of the fan, etc.
7
The channel duct is a versatile system
with a number of applications.
Shown here is a channel duct
mounted on a 360° pivotable
column for wider range.
The channel duct can be combined
with a Hose Reel for even wider
range.
Recommended air flow:
Up to 2.000m³/h per trolley.
Pressure drop for Channel Duct type 25
55
50
Pressure drop [Pa/m]
45
40
35
30
25
20
15
10
5
250
500
750 1000 1250 1500 1750 2000 2250 2500 2750
Airflow [m³/h]
Hose Trolley pressure drop (without hose)
825
750
Pressure drop [Pa]
675
600
525
450
375
300
225
150
75
150 300 450 600 750 900 1050 1200 1350 1500 1650
Airflow [m³/h]
8
C hannel duct
Type 25 Installation examples
L
N
M
I
J
G
K
F
B
H
C
D
A
E
A:
End cover
B:
Ceiling bracket
C:Balancer
D:
Hose mount LWS
E:
Rubber Nozzle
F:
Suspension Bracket type 160
G:
Wall mount
H:
Extraction Arm
(WING/COMPACT)
I:Connection
J:
Outlet Flange, top
K:
Hose Reel with Nozzle
L:
End stop
M:
Channel reduction, end
N:
Pivotable arm 180° or 360°
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
9
Channel Duct
Art. No.
289
600
Description
07-400
Channel Duct type 25 extruded aluminium with neoprene rubber
lips. Lengths of 3 and 6 meter. Height: 291mm. Width: 156mm.
Channel = 256 cm² = ø180 duct. 9 kg/m Price per meter
07-400A
Reinforcement for Channel Duct. Should be used when the
pressure exceeds 1.600 Pa in the Channel Duct and should be
placed for every 2 meters. Per set:
07-401
Channel connection for connecting 2 lengths of Channel Duct.
Galvanized steel
07-402
Assembly kit, for assembling the Channel Duct.
(1 set per lenght of Channel Duct.)
07-477
End stop for trolley
07-478
Spring stop for trolley.
07-403
End cover for type 25 galvanized steel
07-406
End reduction nipple ø250 mm,
From the end of the Channel Ductens to round spiro duct
56-064
Reduction galvanized, sleeve ø250 /nipple ø160
56-065
Reduction galvanized, sleeve ø250 /nipple ø200
07-408
Top mounted poutlet, nipple ø160 mm,
From the top of the Channel Ductens to round spiro duct
07-409
Top mounted poutlet, nipple ø200 mm,
From the top of the Channel Ductens to round spiro duct
07-410
Top mounted poutlet, nipple ø250 mm,
From the top of the Channel Ductens to round spiro duct
07-411
Trolley type 25, powder coated steel. Complete with 6.
smooth-running nylon wheels. ø160 mm nipple connection.
For air flows up to 1.200m³/h.
07-450
Trolley 27 DX powder coated steel. Complete with smooth-running
ball bearing wheels and ø160mm nipple.
Trolley with minimum friction for effortless positioning.
07-430
Trolley 2000M. 8 wheels and ø250mm nipple. (L=1.000mm,
W=200mm, H=289mm).
For air flows up to 2.000m³/h.
07-460
Trolley for Hose Reel FB/LX750.
Price does not include Hose Reel
07-461
Trolley for Hose Reel FB/LX950.
Price does not include Hose Reel
56-042
Reduction MF160/NP80
56-043
Reduction MF160/NP100
56-044
Reduction MF160/NP125
56-045
Reduction MF160/NP150
04-460
Adapter for mounting WING/COMPACT arm on trolley 25
0
20
10
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Suspension of Channel Duct – bracket for every 2 - 4 meter channel duct
Art. No.
Description
07-656
Suspension bracket type 60 galvanized steel.
For mounting in ceiling and on wall (Price each.)
07-424
Spacer tube for suspension bracket 3/8” galvanized per meter
07-422
Set with 2 sleeve bracket for spacer tubes.
2 sets required for each point of fixation.
07-662
Ceiling bracket with tilt function
Suspension kit for Channel Duct
- Content: Supension brackettype 60 (07-656), spacer tube(07-424), sleeve and ceiling bracket.
1 kit required for each point of fixation.
07-620
07-621
07-622
1 meter suspension
2 meter suspension
3 meter suspension
07-150
Shelf bracket for wall mounting. 500x370 (set of 2)
07-151
Shelf bracket for wall mounting.550x400 (set of 2)
07-152
Shelf bracket for wall mounting. 600x440 (set of 2)
07-153
Shelf bracket for wall mounting. 650x475 (set of 2)
07-655
Suspension bracket type 160 galvanized. For mounting on side of
concrete beam.
Automatics for Channel Duct
Art. No.
07-490
Description
Return system for Channel Duct.
Trolley is returned to initial position with the help of small motor
controlled by PLC, frequency converter and sensor.
Wireless start/stop automatics.
Transmitter can be connected to start/stop switch on the Hose Reel eller Channel Duct.
Reciever connects to control board LWS for example.
13-241
13-240
Wireless transmitter - end function- 9V
Wireless reciever- end function- 220V
07-100
Wire Switch LWS for start/stop of fan when balancer is extended.
Max. 1x250V 5A.
Factory mounted on balancer of choice.
07-102
Cable festoon 2x0,75mm² for Wire Switch. L=6m
07-103
Cable festoon 2x0,75mm² for Wire Switch. L=12m
07-104
Cable festoon 2x0,75mm² for Wire Switch. L=15m
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
11
Channel Duct mounted on extension arm or floor column.
Art. No.
07-730
Description
180° extension arm 6m for wall
mounted Channel Duct.
La = 5m
Art. No.
07-750
Note: Channel Duct not included.
Description
360° extension arm 6m with floor
column
H=7,5 m for Channel Duct,
La=5m,L=6m
Custom fitting available upon request
Hose suspension parts / Detatchment systems
Art. No.
12
Description
07-712
Multi hose suspension LWS with balancer bracket.
Suitable for hose dimension ø76 – 152 mm
07-716
Multi hose suspension
Suitable for hose dimension ø76 – 152 mm
07-716A
Multi hose suspension
Suitable for hose dimension ø203 mm
06-600
Safety Coupling ø100
06-601
Safety Coupling ø125
06-602
Safety Coupling ø150
07-107
Automatic detachment system with pressurized air for festoon/
Channel Duct including mounting bracket and ø10mm push-in
fittings.
Including end stop for activating the release valve.
When the trolley reaches the end it will release pressure in the
SB-nozzle.
07-120
As above, but with sensor for bellow nozzle with hand pump.
07-770
Complete electromagnetic detachment system with control, car
nozzle, electromagnet and High Temperature hose.
07-105
Automatic detachment system for SA-Nozzle on Channel Duct.
Supplied with 10m Bowden Cable, activation arm and end stop.
When the trolley reaches the end the vice grip is opened and the
nozzle comes loose causing the damper to close.
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Spring Balance
Art. No.
Description
Lock
[m]
[kg]
Aluminium Spring balancer with steel wire. Progressive pulling force. Weight: 2 - 4 kg
07-220
DT-9336
No
2,5
2,0 - 4,0
07-221
DT-9337
No
2,5
4,0 - 6,0
07-221A
DT-9347D
Yes/No
4,5
4,0 - 6,0
07-223
DT-9338
No
2,5
6,0 - 8,0
07-223A
DT-9348D
Yes/No
4,5
6,0 - 8,0
07-224
DT-9339
No
2,5
8,0 - 10,0
07-224A
DT-9349D
Yes/No
4,5
8,0 - 10,0
07-225
DT-9340
No
2,5
10,0-14,0
07-225B
DT-9350D
Yes/No
4,5
10,0-14,0
07-225A
DT-9346
Yes
2,5
2,0 - 4,0
07-226
DT-9347
Yes
2,5
4,0 - 6,0
07-227
DT-9348D
Yes
2,5
6,0 - 8,0
07-228
DT-9349D
Yes
2,5
8,0 - 10,0
07-229
DT-9350
Yes
2,5
10,0-14,0
07-230
DT-9362
No
2
15,0-20,0
07-231
DT-9363
No
2
20,0-25,0
yes
8
0,0 - 15,0
Special balancer with return brake and linear pulling force.
Suitable for inspection garages and more.
Weight: 12 kg
07-235
SG-15
Progressive pulling force: When released the hose will return at increasing speed.
Linear pulling force: When released the hose will return at a steady speed.
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
13
Garland systems for exhausts.
Air pressure regulator
07-818 End Stop
07-828 Connection
07-817 Bracket 07-816 C-profile 07-82x Bend Trolley
07-8xx Master Trolley
Spring Balancer
Wire Switch
07-712 Hose Suspension
Pressurized Air
Nozzle.
Art. No.
All master and bend trolleys are fitted
with smooth running and low noise
rubber clad steel wheels with ball
bearings.
We recommend one bend trolley for
every 2 meters of profile. Between two
bend trolleys is 2,5m GeoFlex Exhaust
hose.
One bearing for every 3 meters of
C-profile
E.G. 10 m C-profile needs to be fitted
with two 07-818 and two 07-817
Description
07-821
Master Trolley ø100 – With bend 360° pivotable
07-820
Master Trolley ø125 – With bend 360° pivotable
07-819
Master Trolley ø150 – With bend 360° pivotable
07-824
Bend Trolley 100 – 360° pivotable
07-823
Bend Trolley 125 – 360° pivotable
07-822
Bend Trolley 150 – 360° pivotable
01-340
C-profile for festoon, Length= 7,0m
07-828
Connection for C-profile
07-818
Bracket for C-profile. M10 thread - end stop included
07-817
Bracket for C-profile. M10 thread
Tip: By tilting the C-profile 2-7° the hose will automatically return.
14
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Rail system - for vehicles with vertical exhaust pipes.
Art. No.
Description
07-990
Channel duct system for emergency vehicles L = 6.0 m
– complete set incl. 2 sliding, self-centering suspension
brackets for the ceiling, inlet guide and exhaust adapter.
The suspension bracket is height adjustable from 1.0 – 2.5
m. The Channel duct system is 500 mm slidable to both
sides. The exhaust adapter may be mounted on exhaust
pipes from approx. 95 – 120 mm. The Channel duct system
for emergency vehicles is connected to the channel system
via an ø250 mm reduction piece at the end.
07-991
Channel duct system for emergency vehicles L = 9.0 m
– complete set incl. 2 slidable, self-centering suspension
brackets for the ceiling, inlet guide and exhaust adapter.
The suspension bracket is height adjustable from 1.0 – 2.5
m. the Channel duct system is 500 mm slidable to both
sides. The exhaust adapter may be mounted on exhaust
pipes from approx. 95 – 120 mm. The Channel duct system
for emergency vehicles is connected to the channel system
via an ø250 mm adapter at the end.
Other models available on request.
Emergency Rail System- type FBER
Art. No.
Description
07-995
Emergency rail system L = 7,0 m - complete solution
including horisontally moveable profile, suspension bracket,
hose and inlet guide.
The extraction will follow the exhaust pipe all the way to
the end of the rail.
10 m ø160mm compressable hose is suspended for
every 0,7 m. Max. temp. 150°C.
07-996
As above but for vehicles with side mounted exhaust pipes.
Electromagnetic detachment system.
07-997
As above but for vehicles with side mounted exhaust pipes.
Pneumatic detachment system.
Automatics for emergency vehicles.
Art. No.
Description
19-111
Control panel for remote controlled transmitter.
Automatically starts the fan, when the car is started.
Range 50-100 m, subsequently the fan is turned off.
19-110
Wireless transmitter for start/stop of the fan.
To be connected to 24V battery on the vehicle.
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
15
Exhaust Nozzles.
Art. No.
Description
Exhaust
Hose
Conn.
Weight
SK - Nozzle - Powder coated steel with flap and opening for CO2- probe
06-008
06-009
06-029
06-028
SK-80
SK-100
SK-125
SK-150
ø70
ø90
ø115
ø140
ø80
ø100
ø125
ø150
1,30 kg
2,05 kg
3,05 kg
3,10 kg
ø100
ø125
ø150
ø200
1,6 kg
1,9 kg
2,15 kg
2,7 kg
HT - Nozzle - Powder coated steel w. vice grip. For very hot exhaust.
06-328
06-329
06-330
06-331
HT-100
HT-125
HT-150
HT-200
ø80
ø105
ø135
ø180
S - funnel shaped rubber nozzle. Available with opening for CO2-probe.
06-168
06-168A
S-65/90
S-65/90,
w. tight damper
ø90
ø90
ø80
ø80
0,65 kg
1,35 kg
06-167
06-167A
S-80/130
S-80/130,
w. tight damper
ø130
ø130
ø80
ø80
0,80 kg
1,50 kg
06-166
06-166A
S-100/150
S-100/150, w. tight damper
ø150
ø150
ø100
ø100
0,85 kg
1,40 kg
06-169
06-169A
S-100/150
S-100/150, w. tight damper
ø150
ø150
ø125
ø125
0,90 kg
1,45 kg
ø150
ø150
ø190
ø190
ø190
ø190
ø100
ø100
ø125
ø125
ø150
ø150
1,45 kg
2,00 kg
2,10 kg
3,35 kg
1,90 kg
3,15 kg
SA - funnel shaped rubber nozzle. With vice grip and net.
06-163
06-163A
06-164
06-164A
06-165
06-165A
SA ø100/150
SA ø100/150, w. tight damper
SA ø125/190
SA ø125/190, w. tight damper
SA ø150/190
SA ø150/190, w. tight damper
06-160
SA ø100/150mm
w. automatic damper
ø150
ø100
2,05 kg
06-161
SA ø125/190mm
w. automatic damper
ø190
ø125
3,05 kg
06-162
SA ø150/190mm
w. automatic damper
ø190
ø150
2,85 kg
Note: Standard automatic damper shuts off 90% of the airflow.
SE - Oval rubber nozzle with vice grip and a 60° bend.
16
06-170
FOR SALOON CARS
SE-75/150
150/75
ø80
1,75 kg
06-171
SE-100/150
150/75
ø100
1,70 kg
06-172
SE-125/150
150/75
ø125
1,75 kg
06-173
FOR LORRIES
SE-125/200
200/120
ø125
2,40 kg
06-174
SE-150/200
200/120
ø150
2,60 kg
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Rubber Nozzles for Exhaust
Art. No.
Description
Exhaust
Hose
Conn.
Weight
PO - Oval rubber nozzle with 60° bend
06-193
06-195
PO-80/130
PO-80/130, W. Tight Damper
125/65
125/65
ø80
ø80
0,85 kg
1,55 kg
06-194
06-196
PO-100/130
PO-100/130, W. Tight Damper
125/65
125/65
ø100
ø100
0,65 kg
1,20 kg
ø100
0,55 kg
GeoFlexgrip - Oval rubber nozzle, which will close when not in use.
06-140
GeoFlexGrip 140/25
ø75
06-139
GeoFlexGrip 180/30
ø100
ø100
0,90 kg
06-142
GeoFlexGrip 240/15
ø125
ø150
1,30 kg
SB - Round Rubber Nozzle with bellows for hand pump or pressurised air.
06-350
06-354
06-355
06-360
06-360A
SB 100/80
SB 100/100
SB 160/150
SB 200/150
SB 250/150
ø100
ø100
ø160
ø200
ø250
ø80
ø100
ø150
ø150
ø150
0,90 kg
0,90 kg
1,30 kg
1,60 kg
2,00 kg
SBM - Oval Rubber Nozzle with bellows for hand pump or pressurised air.
06-364A
06-364B
SBM 120/40 (mini cars)
SBM 120/40 (mini and
smaller cars)
120/40
ø80
0,85 kg
120/40
ø100
0,70 kg
06-368A
SBM 200/100 (smaller lorries with
stroke bore less than 3,0 l)
200/100
ø125
1,35 kg
06-368B
SBM 200/100 (lorries)
200/100
ø150
1,60 kg
SBM - Oval rubber nozzle with bellows for hand pump or pressurised air. With 45° bend.
06-365A
SBM 150/80 (small and medium sized cars)
150/80
ø100
1,00 kg
06-365B
SBM 150/80 (Medium and
larger cars less than 3,0 L)
150/80
ø125
1,10 kg
06-369
Hand pump for pressurised nozzle
06-369A
Quick release valve for pressurised nozzle
06-379
Slide valve for pressurised nozzle
12-006A
Turning damper, ø100, for nozzle
12-007A
Turning damper, ø150, for nozzle
06-363
Pressure regulator for nozzle SB with pressure gauge, ø10mm
push-in fittings and mounting bracket
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
17
Nozzles for Hose Reel, Channel Duct and hose lift
Art. No.
Description
06-356
Compressed air feeding set for Hose Reel L=max.10 m
06-357
06-358
06-359
Compressed air feeding set with
garland for Channel Duct included:
L = max 6 m
L = max 12 m
L = max 18 m
06-356A
Compressed air feeding set for hose garland, L=max.18 m
07-035
AU2 ø150 mm height adjustable holder.
Well suited for test stands
07-040
AU2 ø200 mm height adjustable holder.
Well suited for test stands
06-250
FBE hose cart ø100. height adjustable and easy to place.
06-251
FBE hose cart ø125. height adjustable and easy to place.
06-252
FBE hose cart ø150. height adjustable and easy to place.
Y-coupling set for cars with dual exhaust pipe
06-389
Y-piece 100/100/45° complete, 2 ø100 GeoFlex Exhaust 1,25m hoses
06-390
Y-piece 100/100/45° complete with click coupling VL,
2. ø100 GeoFlex Exhaust 1,0m hoses
06-390A
Y-piece 100/100/45° complete with click coupling VL,
2. ø100 GeoFlex Exhaust 1,0m High temperature hoses
Note: Nozzles not included
06-200
Extended nozzle ø125/250 – H = 2m. Well suited for construction
equipment with vertical exhaust pipe
06-200A
Extended nozzle ø125/250 – H = 2m. Well suited for construction
equipment with vertical exhaust pipe. With 300°C Hose
Hood for Hose Reel, ASA-/MINI- arms and more
Art. No.
18
Description
Weight
10-244
10-246
10-245
Ø160 Hood with magnet
Ø200 Hood with magnet
Ø160 Hood with magnet incl. adaptor ø150
1,7 kg
1,9 kg
1,9 kg
12-008
12-009
Tight damper ø160
Tight damper ø200
0,15 kg
0,20 kg
06-014
06-015
Welding hood ø80 with magnet
Welding hood ø80 with magnet and tight damper
1,0 kg
1,2 kg
06-020
06-021
Welding hood ø100 with magnet
Welding hood ø100 with magnet and tight damper
1,1 kg
1,3 kg
06-025
06-026
Welding hood ø125 with magnet
Welding hood ø125 with magnet and tight damper
1,3 kg
1,5 kg
06-051
06-052
MINI-hood ø80 with magnet
MINI-hood ø80 with magnet and tight damper
0,65 kg
0,65 kg
06-053
MINI-hood ø100 with magnet
06-054
MINI-hood ø80 with magnet and tight damper
06-240
Extraction screen f/emergency vehicles
10-265
Flange f/hood-ø125 hose
10-266
Flange f/hood-ø160 hose
10-267
Flange f/hood-ø200 hose
Custom hoods available on request. Please enquire.
0,65 kg
0,65 kg
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Examples of equipment for emergency vehicles
GARLAND RAIL W. AUT. DETATCHMENT
A: Spiro duct ø160 with reduction valve for compressed air
B: Fan MSFG-200-3, 1.1kW – capable of supplying up to 2,100 m³/h air.
C: Balancer Trolley. The trolley slides horizontally
in the direction of travel.
D: Connecting piece for rail system. The system
consists of 6 meter pieces to be assembled to
the required length.
E: Suspension bracket for the mounting of the
rail system in the ceiling.
F: Release device, transmitting a signal to reduce
the pressure in the nozzle, and then the nozzle
is detached from the exhaust pipe.
CHANNEL DUCT FOR EMERGENCY VEHICLES
A: Box fan – for the extraction from a vehicle,
MSFG-200-3, 1.1kW – Max 2,100 m³/h.
B: Fixed spiro duct connection.
C: Flexible hose, securing the regulation/movement
of the Channel duct.
D: Suspension bracket, which can slide the Channel
duct in the same direction as the vehicle.
E: The vertical exhaust pipe of the vehicle.
F: Inlet guide to catch the exhaust pipe in order
for it to be guided into the Channel duct. The
system is activated via excess pressure.
GARLAND RAIL SYSTEM / C-PROFILE SYSTEM
A: Spiro duct ø200, reduction valve for
compressed air.
B: Fan MSFG-200-3, 1.1 kW – capable of
supplying up to 2,100 m³/h air.
C: Spring balancer holder with wheels, capable of
sliding horizontally in the rail system.
D: Connecting piece for rail system. The system
consists of 6 meter pieces to be assembled to
the required length.
E: Suspension bracket for the mounting of the
rail system in the ceiling.
F: Release device, transmitting a signal to reduce
the pressure in the nozzle, and then the nozzle
is detatched from the exhaust pipe.
EXTRACTION SHIELD
A: Extraction shield 1000 x 1000 x 800 mm with
vertical outlet and suspension bracket.
B: Steel wire with turnbuckles.
C: Fan MSFG-200-3 – for the extraction from one
vehicle.
D: Silencer ø250 mm.
E: Spiro duct ø200 mm.
F: Ceiling
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
19
Examples of equipment for emergency vehicles
CHANNEL DUCT W. MECHANICAL REL. SYSTEM
A: Box fan - MSFG-200-3
B: Transition piece to round channel from the duct.
C: Mechanical release system; releases the nozzle
from the exhaust pipe at the end of the channel
duct. The mechanism works by means of a steel
wire releasing the vice grip on the nozzle.
D: Spring balancer to facilitate the operation of
the equipment and which ensures that the hose
is not in the way.
E: The suspension brackets must be fixed at intervals of 2500 to 4000 mm in order to secure the
stable installation.
F: Release station, activating the wire set in such
a way that the nozzle is released just before the
trolley reaches the end of the channel duct.
CONICAL NOZZLE, FIXED TO THE FLOOR
A: Silencer
B: Fan MSFG-200-3, 1.1 kW, max. 2,100m³/h.
C: ø200 mm spiro duct and bend.
D: GeoFlex exhaust hose with a temperature resistance of up to 150°C.
E: Wire, fixed to the floor, ensuring that the
nozzle detatches from the vehicle .
F: Rubber nozzle to be pushed over the exhaust
pipe. Suits several exhaust pipe dimensions.
CHANNEL DUCT W. PNEUMATIC detatchment
A: Box fan – MSFG-200-3 1.1 kW
B: Activation switch, sending a signal to the
control panel to start or stop the fan.
C: Spring balancer, securing easy operation of the
equipment and that the hose is not in the way.
D: GeoFlex exhaust pipe with a temperature
resistance of up to 150°C. The lower part of the
hose is a safety pull-out coupling, securing that
the nozzle is released in case of defects.
E: Wire switch LWS for the start/stop of the fan.
F: The suspension brackets must be fi xed at intervals of 2500 to 4000 mm in order to secure the
stable installation.
G: Bracket, which at the end station sends a signal
to reduce the compressed air in the nozzle so
that immediately hereafter it is released automatically from the vehicle.
HOSE REEL WITH AU2 FUNNEL
A: Hose reel with 10 meters of ø150 GeoFlex
exhaust (max 150°C).
B: Fan MSFG-200, 1.1kW – Max 2,100m³/h.
C: Spiro pipe ø200
D: AU2 funnel, placed immediately behind the
exhaust pipe
20
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Examples of equipment for emergency vehicles
Single duct with motor driven Hose
trolley for Channel duct
Channel duct system without return rail, but with
motor driven trolley. When the hose is pulled down
and the nozzle is connected to the car exhaust
pipe, the fan is switched on automatically. The
trolley is pulled forward by the hose connected to
the exhaust pipe. When the trolley reaches the end
of the duct, the nozzle is disconnected automatically, the fan turns off and the trolley returns to
the starting point.
Pneumatic release system
Pneumatic release system with automatic start/
stop of the fan and compressed air nozzle, which is
automatically released, when the trolley reaches
the end of the channel duct.
The system is available with standard brackets,
adjustable to any ceiling.
The compressed air nozzle fits perfectly on the exhaust pipe and is completely tight. The nozzle can
be used in combination with a motor driven trolley
for automatic return of the trolley.
Inlet guide
Channel duct system for fire engines with vertical
exhaust pipes. The fan automatically starts as a
function of excess pressure in the channel duct as
a result of the exhaust gas from the fire engine.
The fan stays on for up to 59 minutes (adjustable).
Horizontally sliding suspension makes driving to
and from the garage effortless. Even if the vehicle
is not completely parallel to the system, when
driving into the garage, the channel duct will slide
in the same direction as the vehicle.
The inlet guide is placed at the end of the channel
duct. When parking the vehicle, the exhaust pipe
of the vehicle must point in the direction of the
inlet guide, and subsequently the channel duct will
follow the exhaust pipe and remove the exhaust
gasses.
The Channel Duct Systems are highly customizable - Enquire for further possible solutions.
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
21
extensi o n A rms
4m. Extension arm
HVU Arm
HVU Arm
22
ASX ATEX arm
W ing arm
WING ARM
WING arm
The classic point extraction arm.
The WING-arm construction is more than 40 years old,
but with small improvements over the years, it
is still one of the best choices when selecting a new
extraction arm.
The latest improvements made to the arm have
improved manoeuvrability and positioning capability
considerably.
Available with aluminium pipe on request.
Lengths: 2, 3 and 4 m or up to 8 m, when using an extension arm.
Dimensions: ø160 and ø200 mm
Dimensions WING arm
Extension arms
All arms may be extended with an extension arm.
The 2.5 meter long extension arm shown above will
generate a pressure drop of 160 Pa at 1,000 m³/h.
The 4.0 meter extension arm shown below will
generate a pressure drop of 300 Pa at 1,000 m³/h.
23
C O M PCAoCmpact
T A R M arm
COMPACT arm
Dimensions COMPACT arm
This extraction arm is designed to fit into welding
booths or other places where space is sparse.
Because of it´s telescopic abilities, it can easily be
positioned, where it is needed –
simply the best solution, when there is no room for a
large arm.
24
1-2 and 1.5-3 m or up to 7 m
with an extension arm.
ø160 and ø200 mm
Typical height over table: 1 - 1.75 m
Lengths: Dimensions: ø160/200
A S A arm
ASA ARM
ASA-3 arm
Dimensions ASA arm
The ASA-3 arm is recognized for its easy manoeuverability,
ergonomics and efficiency.
The external arm ensures minimum pressure drop and
maximum flexibility.
The ASA-3 arm is also available with aluminium pipe = ASA-4.
Lengths: 2, 3 or 4m or up to 8 m when using an extension arm.
Dimensions: ø80, ø100, ø125, ø160 and ø200 mm
ASA-4 arm
The ASA-4 arm is similar to the ASA-3 arm but is fitted with
aluminium ducts in stead of hose.
Arm
A
B
D
E
F
Tragt
C
G
2,0 m
920
680
206
120
200
ø80
180
178
3,0 m
1420
1180
206
120
200
ø100
180
198
4,0 m
1870
1710
206
120
200
ø125
180
223
ø160
318
360
ø200
318
360
25
arm
F L E X I - AFRlexi
M
D
C
Dimension: ø100 eller ø125
A
Længde:
B
1,0 eller 1,5 meter
Montering: Væg, loft, bord eller skab
Slange:
GeoFlex White (140°C)
The unique design of the Geovent FLEXI-arm has been
developed especially for the purpose of removing
polluted air from laboratories, hospital environments,
cliniques, etc. By removing the polluted air direct at the
source, the exposure of the employees to air causing
local irritation and toxic vapours is minimized, resulting
in a better working environment.
Dimension: ø100 or ø125
Length: 1.0 or 1.5 meter
Installation: Wall, ceiling, table or cupboard
Hose: GeoFlex White (140°C)
Three friction actuated joints as well as a 360°
smooth-running swivel suspension secures that the arm
may be positioned in any required position within the
working area, thus resulting in easy and effortless use of
the FLEXI-arm every day.
26
E
A:
FLEXI-arm in the flange model FFK for table mounting with custom polycarbonate hood.
B:
The FLEXI-arm is available with several different types of hood, both in aluminium and in clear polycarbonate.
Here the arm is shown with an ø385mm clear polycarbonate dome-shaped hood.
C:
FLEXI-arm, model FVK for wall mounting.
D:
FLEXI-arm, model FLK for ceiling mounting with 360° swivel ceiling bracket.
The bracket is manufactured according to customer requirements.
E:
FLEXI-arm, model FFK mounted under laboratory cupboard.
WING arm with internal articulated support arm
Art. No.
Note: Wall bracket
not included
Description
01-008
WING-arm 2,0 m ø160 mm - rec. air flow 800-1.000m³/h
01-009
WING-arm 3,0 m ø160 mm - rec. air flow 800-1.000m³/h
01-007
WING-arm 4,0 m ø160 mm -rec. air flow 800-1.000m³/h
01-007A
WING-arm 2,0 m ø200 mm - rec. air flow 1.200-1.500m³/h
01-008A
WING-arm 3,0 m ø200 mm -rec. air flow 1.200-1.500m³/h
01-009A
WING-arm 4,0 m ø200 mm - rec. air flow 1.200-1.500m³/h
Also available with aluminium pipes instead of hose - additional price per arm
WING-arm with quick-coupling and ball swivel joint
Art. No.
1.30
0m
m
Description
01-202
Wing arm ø160mm, 2 m – with quick-coupling/ball joint - w/o hood
01-200
Wing arm ø160mm, 3 m – with quick-coupling/ball joint - w/o hood
12-243
Extraction hood for windscreen gluing 850x600 mm of
polycarbonate with quick-coupling ø160
12-243A
Extraction hood for windscreen gluing 850x600 mm of
polycarbonate with quick-coupling ø160
12-242
Panel fume extractor ø160x1300 mm of aluminium with
quick-coupling
10-247
Detachable welding hood ø160/385 for quick-coupling uncoupling
- with 25 mm suction edge
01-226
Counterpart for quick-coupling ø160 (for hoses)
91-289
Quick-coupling ø160
COMPACT arm, with internal, telescopic support arm
Art. No.
Tele
s
cop
ic
Note! wall console
not included
Description
01-700
COMPACT arm 1 – 2 m. telescopic, ø160 mm
01-706
COMPACT arm 1,4 – 3 m. telescopic, ø160 mm
01-701
COMPACT arm 1 – 2 m. telescopic, ø200 mm
01-707
COMPACT arm 1,4 – 3 m. telescopic, ø200 mm
Pressure drop curves - Wing arm
[Pa]
WING arm 2m
1400
ø160
1200
ø200
[Pa]
WING arm 3m
1400
ø160
1200
ø200
[Pa]
1000
1000
1000
800
800
800
600
600
600
400
400
400
200
200
200
200
400
600
800
1000 1200 1400 1600 1800 2000 2200
Air flow [m³/h]
200
400
600
800
1000 1200 1400 1600 1800 2000 2200
Air flow [m³/h]
WING arm 4m
1400
ø160
1200
200
400
600
800
ø200
1000 1200 1400 1600 1800 2000 2200
Air flow [m³/h]
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
27
Accessories for WING, COMPACT arm and Slot Nozzle Extraction
Art. No.
A
H
Description
01-540
Wall Console ø160 mm, 260 mm from wall
01-541
Wall Console ø200 mm, 280 mm from wall
01-550
Wall Console ø160 mm, 1.000 mm from wall
01-550A
Wall Console ø200 mm, 1.000 mm from wall
01-130
Extension arm arm 2,5 m ø160 mm
01-130A
Extension arm arm 2,5 m ø200 mm
01-138
Extension arm arm - 1-joint 4,0m ø160mm
01-139
Extension arm arm - 1-joint 4,0m ø200mm
01-131
Extension arm arm - 2-joint 4,0 m. ø160 mm
01-132
Extension arm arm - 2-joint 4,0 m, ø200 mm
01-160
Ceiling console ø160, length 0,4 - 1,2M
01-161
Ceiling console ø160, length 1,2 - 2,4M
01-162
Ceiling console ø200, length 0,4 - 1,2M
01-163
Ceiling console ø200, length 1,2 - 2,4M
12-008
Tight Damper for hood- ø160mm
12-009
Tight Damper for hood– ø200mm
01-173
Halogen set R2 incl. mesh– excl. trafo
01-173A
Halogen set R3 - excl. trafo
01-179
Trafo 70 W electronic, 12V
10-253
Hood WING/COMPACT ø160
10-256
Hood WING/COMPACT ø200
Fan (MSQ) for mounting on wall console - See fan section.
Polycarbonate hoods for WING/COMPACT-arm - See under accessories.
Pressure drop curves - Compact arm
[Pa]
COMPACT arm 1-2m
1400
ø160 ø200
1200
1000
800
600
600
400
400
200
200
600
800
1000 1200 1400 1600 1800 2000 2200
Airflow [m³/h]
ø160
1200
800
400
COMPACT arm 1,5-3m
1400
1000
200
28
[Pa]
200
400
600
800
ø200
1000 1200 1400 1600 1800 2000 2200
Airflow [m³/h]
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
ASA-3 arm, with external, articulated arm, hose and gas spring
Art. No.
Description
ASA-01
ASA-3 arm 2,0 m ø80 mm, Complete
ASA-05
ASA-3 arm 2,0 m ø80 mm, Complete, with tight damper
ASA-11
ASA-3 arm 3,0 m ø80 mm, Complete
ASA-15
ASA-3 arm 3,0 m ø80 mm, Complete, with tight damper
ASA-02
ASA-3 arm 2,0 m ø100 mm, Complete
ASA-06
ASA-3 arm 2,0 m ø100 mm, Complete, with tight damper
ASA-12
ASA-3 arm 3,0 m ø100 mm, Complete
ASA-16
ASA-3 arm 3,0 m ø100 mm, Complete, with tight damper
ASA-22
ASA-3 arm 4,0 m ø100 mm, Complete
ASA-26
ASA-3 arm 4,0 m ø100 mm, Complete, with tight damper
ASA-03
ASA-3 arm 2,0 m ø125 mm, Complete
ASA-07
ASA-3 arm 2,0 m ø125 mm, Complete, with tight damper
ASA-13
ASA-3 arm 3,0 m ø125 mm, Complete
ASA-17
ASA-3 arm 3,0 m ø125 mm, Complete, with tight damper
ASA-23
ASA-3 arm 4,0 m ø125 mm, Complete
ASA-27
ASA-3 arm 4,0 m ø125 mm, Complete, with tight damper
ASA-04
ASA-3 arm 2,0 m ø160 mm, Complete
ASA-08
ASA-3 arm 2,0 m ø160 mm, Complete, with tight damper
ASA-14
ASA-3 arm 3,0 m ø160 mm, Complete
ASA-18
ASA-3 arm 3,0 m ø160 mm, Complete, with tight damper
ASA-24
ASA-3 arm 4,0 m ø160 mm, Complete
ASA-28
ASA-3 arm 4,0 m ø160 mm, Complete, with tight damper
ASA-31
ASA-3 arm 2,0 m ø200 mm, Complete
ASA-32
ASA-3 arm 2,0 m ø200 mm, Complete, with tight damper
ASA-33
ASA-3 arm 3,0 m ø200 mm, Complete
ASA-34
ASA-3 arm 3,0 m ø200 mm, Complete, with tight damper
ASA-35
ASA-3 arm 4,0 m ø200 mm, Complete
ASA-36
ASA-3 arm 4,0 m ø200 mm, Complete, with tight damper
Pressure drop curves- ASA-3 arm
[Pa]
[Pa]
ASA-3 arm 2m
1400
1200
ø100
ø125
ø160
ø200
[Pa]
ASA-4 arm 3m
1400
ø160
1200
ø200
1000
1000
800
800
600
600
600
400
400
400
200
200
200
200
400
600
800
1000 1200 1400 1600 1800 2000 2200
Airflow [m³/h]
200
400
600
800
1000 1200 1400 1600 1800 2000 2200
Air Flow [m³/h]
ø125
1200
800
1000
ASA-3 arm 4m
1400
ø160
ø200
ø100
200
400
600
800
1000 1200 1400 1600 1800 2000 2200
Airflow [m³/h]
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
29
ASA-4 arm, with external, articulated arm, alu pipe and gas spring
Art. No.
Description
ASA4-2-160 ASA4 arm 2m with ø160mm alu-pipe, complete
ASA4-2-200 ASA4 arm 2m with ø200mm alu-pipe, complete
ASA4-3-160 ASA4 arm 3m with ø160mm alu-pipe, complete
ASA4-3-200 ASA4 arm 3m with ø200mm alu-pipe, complete
ASA4-4-160 ASA4 arm 4m with ø160mm alu-pipe, complete
ASA4-4-200 ASA4 arm 4m with ø200mm alu-pipe, complete
MINI arm, with external, articulated arm and hose
Art. No.
Description
MINI-01
MINI arm 1,0 m ø80, complete
MINI-04
MINI arm 1,0 m ø80, complete with tight damper
MINI-02
MINI arm 1,0 m ø100, complete
MINI-05
MINI arm 1,0 m ø100, complete with tight damper
MINI-03
MINI arm 1,0 m ø125, complete
MINI-06
MINI arm 1,0 m ø125, complete with tight damper
01-085
MINI arm 1,0 m with wall/table console.
Hose and hood not included.
See accessories and hoods on next page.
Dimensions MINI arm
Pressure drop curves- ASA-4 arm
[Pa]
ø160
1200
ø200
[Pa]
ASA-4 arm 2m
1400
ø160
1200
1000
1000
800
800
600
600
600
400
400
400
200
200
200
600
800
1000 1200 1400 1600 1800 2000 2200
Air Flow [m³/h]
200
400
600
800
1000 1200 1400 1600 1800 2000 2200
Air Flow [m³/h]
ø160
1200
800
400
ASA-4 arm 4m
1400
ø200
1000
200
30
[Pa]
ASA-4 arm 3m
1400
200
400
600
800
ø200
1000 1200 1400 1600 1800 2000 2200
Air Flow [m³/h]
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Accessories for MINI, ASA-3 and ASA-4 arm
Art. No.
Description
06-121
Hood ø80 mm for ASA-3 and MINI arm
06-122
Hood ø100 mm for ASA-3 and MINI arm
06-123
Hood ø125 mm for ASA-3 and MINI arm
10-251
Hood ø160 for ASA-3 arm
10-255
Hood ø200 for ASA-3 arm
10-260
Extension arm 1 m for ASA-3 arm
01-130B
Extension arm 2,5 m for ASA-3 arm - ø160 mm
01-130C
Extension arm 2,5 m for ASA-3 arm - ø200 mm
01-131D
Extension arm 4,0 m for ASA-3 arm, 1 joint – ø160 mm
01-131E
Extension arm 4,0 m for ASA-3 arm, 1 joint – ø200 mm
01-131B
Extension arm 4,0 m for ASA-3 arm, 2 joints – ø160 mm
01-131C
Extension arm 4,0 m for ASA-3 arm, 2 joints – ø200 mm
01-127
Floor column for mounting of extraction arm.
(ASA-3, ASA-4, WING and COMPACT).
H: 2500mm Floor plate: 330x330mm
Please state type of arm when ordering.
10-202
ASA-arm (W/ gas spring) and wall console. 2,0m w/o hood
10-203
Separate ASA-arm (W/ gas spring) and wall console. 3,0m w/o hood
10-204
Separate ASA-arm (W/ gas spring) and wall console. 4,0m w/o hood
Polycarbonate hoods for ASA-arm -see under accessories.
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
31
FLEXI arm, Internal, articulated arm and hose.
Art. No.
Description
Flange model for table or overhanging cupboard mounting.
01-572
FLEXI arm FFK ø100 mm 1,0m
01-573
FLEXI arm FFK ø100 mm 1,5m
01-502
FLEXI arm FFK ø125 mm 1,0m
01-503
FLEXI arm FFK ø125 mm 1,5m
Wall mounting
A
H
01-570
FLEXI arm FVK ø100 mm 1,0m
01-571
FLEXI arm FVK ø100 mm 1,5m
01-500
FLEXI arm FVK ø125 mm 1,0m
01-501
FLEXI arm FVK ø125 mm 1,5m
01-585
Extension arm 0,5 m for FLEXI arm
01-586
Extension arm 1,5 m for FLEXI arm
Ceiling mounting - console with custom measurements:
Length A = minimum 0,25 m – max 1,8 m
Length H = minimum 0,5 m – max 2,0 m
Prices including custom ceiling mounting console:
01-560
FLK-100 1,0 m
01-561
FLK-100 1,5 m
01-562
FLK-125 1,0 m
01-563
FLK-125 1,5 m
Pressure drop curve- FLEXI-arm
[Pa]
800
600
400
Flexi-arm ø100 1,5 m
Flexi-arm ø100 1,0 m
Flexi-arm ø125 1,5 m
Flexi-arm ø125 1,0 m
200
100
32
200
300
Air Flow [m3/h]
400
500
600
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
FLEXI arm – Accessories/spare parts
Art. No.
Description
06-136F
Standard hood ø100 (powder coated aluminium)
06-060F
Standard hood ø125 (powder coated aluminium)
12-006
Tight damper ø100 mm for use in hood
12-012
Tight damper ø125 mm for use in hood
FLEXI arm is by default powder coated white, RAL9016 gloss 60.
Other hoods by request.
Polycarbonate hood - For all Geovent arms
Art. No.
Description
Transparent PolyCarbonate hood ø500 mm:
01-568
Hood w/ Ø100 mm connection
01-569
Hood w/ Ø125 mm connection
01-548
Hood w/ Ø160 mm connection
01-549
Hood w/ Ø200 mm connection
Transparent PolyCarbonate hood ø385 mm:
01-566
Hood w/ Ø100 mm connection
01-567
Hood w/ Ø125 mm connection
01-546
Hood w/ Ø160 mm connection
01-547
Hood w/ Ø200 mmconnection
Transparent PolyCarbonate hood ø280 mm:
01-564
Hood w/ Ø100 mm connection
01-565
Hood w/ Ø125 mm connection
01-545
Hood w/ Ø160 mm connection
Transparent PolyCarbonate hood 265 x 168 mm:
01-558
Ø100 mm connection
01-559
Ø125 mm connection. Note: with reduction ø100
Transparent PolyCarbonate hood 330 x 245 mm:
01-556
Ø100 mm connection
01-557
Ø125 mm connection
For all polycarbonate hoods: please state which arm they are used for:
A: ASA (ex. 01-568A)
F: Flexi (ex. 01-568F)
W: Wing/Compact (ex. 01-568W)
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
33
FILTERS
GEOVENT filters are used in a number of different
processes such as filtering welding smoke and oil mists.
Our filters live up to increasingly strict requirements
and ensures a healthy working environment.
An effective filter facilitates heat recovery.
By recovering heat from extracted air, the energy use
is minimized and contribute to a reduction in CO2
emission.
FILTER STANDARDS
Geovent filter cartridges are manufatured in
compliance with the high standards of
BIA-classification.
34
OIL MIST FILTERS
GFO 315 Filter
The Geovent GFO filter is used for filtration of oil mists
from CNC lathes, cutting and drilling machinery, etc., and
has a capacity of up to 1,200 m³/h with a filtration
efficiency of 99.9% at 0.3μm.
The filter is easy to install and service and it has a tap for
recycling of collected oil.
GEOVENT oil mist filters are available in different
versions to suit different needs.
The smaller Geofilter Oil covers the need for cutting
machines up to 600 m³/h.
GFO XT has a capacity of up to 14.400 m³/h. per unit.
The filters can be connected in parallel to handle larger
air flows. The filter cartridge is a polypropylene filter
membrane, which tolerates both oil and water-based
mists and smoke.
Filtered liquids may be reused in the machinery, thus
saving money on liquid consumption.
35
DUST FILTERS
GEOVENT filters range from 200 m³/h til 7.200 m³/h.
Higher capacity can be reached by connecting several
filters in parrallel.
The filters are capable of removing up to 99,97 % of
hazardous particles.
GFB Filter
The GFB filter is an inexpensive, complete and modular
filter soltion for with an airflow capacity of up to
7,200 m³/h per unit.
The GFB filter is supplied complete with an easily
programmable and fully automatic compressed air
GEOVENT DustBox has been developed for smaller
cleaning system.
installations requiring a high degree of filtration.
The GFB filter is used in a number of industries, with
(99,9%),
different processes such as welding, grinding, plasma/
It can be used with existing installations or as a
laser cutting, powder coating and more.
stand alone module with a built-in fan.
36
The DustBox has a large filter area and thus a low
•
3 filter cartridges per shot valve.
pressure drop and less wear.
•
Collection bucket with a capacity of
25 litres of dust.
GeoFilter Oil – Oil mist filtration
Art. No.
Description
15-020
Geofilter Oil 100 400x400 – 95% Filtration at 0,3µm.
Max. air flow: 400 m³/h. Initial Pressure Drop: 100 Pa at 400 m³/h.
15-220
Geofilter Oil 160 400x600 – 95% filtration at 0,3µm.
Max. air flow: 600 m³/h. Initial Pressure Drop 150 Pa at 600 m³/h.
15-030
Seperate aluminium filter mat 400 x 400mm
15-031
Seperate aluminium filter mat 400 x 600mm
GFO 315 – 99,95% Oil mist filtration
Art. No.
Description
15-320
GFO-315 - 99,95% Oil mist filtration at 0,3µm.
Max air flow: 1.200 m³/h. inlet = ø200mm, outlet = ø315mm
15-335
Filter cartridge for GFO filter
GFO XT – for oil mist filtration at several work stations
GFO XT – 99.9% filtration of oil mists at 0.3μm. The filter is used as zone filter for large processing centres, for example, or as central filter for several lathes/cutters, etc.
The filter has a 6 m² polyproplylene filter cartridge. Recommended end pressure drop =
1,200 Pa. H:1500 mm, W: 300 mm, D: 300 mm, connection/outlet = ø250 mm nipple. 20 litres
reservoir with discharge tap and sight glass for oil level control.
Art. No.
Description
15-353
15-354
15-355
15-356
GFO XT-3
GFO XT-6
GFO XT-9
GFO XT-12
15-335
Replacement cartridge for GFO filter
Filter area
Max m³/h
30 m²
60 m²
90 m²
120 m²
2.500
5.000
7.500
10.000
GFO filter
Box Fan MSFG
200-3
1650
1500
Pressure drop [Pa]
1350
Spiro duct ø200
1200
1050
Geofilter Oil 100
900
750
600
Spiro duct ø100
450
300
Lower curve = clean filter
Upper curve = dirty filter
ASA-arm
w. hood ø100
150
200 400 600 800 1000 1200 1400 1600 1800 2000 2200
Airflow [m³/h]
Example of installation
Geofilter Oil
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
37
Geofilter Dust
Art. No.
Description
15-051
GeoFilter Dust with 500 x 500 mm EU3 surface filter
(85% filtration at 0.3μm)
Max. air flow: 1,500 m³/h. Connection ø315 mm NP
15-035
Replacement filter EU5 (95% filtration at 0.3μm) 500x500 mm
forGeoFilter Dust
15-036
Replacement filter EU3 (85% filtration at 0.3μm) 500x500 mm
forGeoFilter Dust
56-074
Reduction MF315/NP160 mm for GeoFilter Dust
56-075
Reduction MF315/NP200 mm for GeoFilter Dust
GeoFilter GF4
Art. No.
Description
The GF4 filter is designed for smaller concentrations of dust. Manual cleaning.
Filtration up to 99 %, dep. on filtertype. Max. airflow: 4.000 m³/h
15-504
GeoFilter GF4-1 EU3 86% filtration at 0,3 µm -ø400
1023
645
15-503
GeoFilter GF4-2 EU5 95% filtration at 0,3 µm –ø400
15-502
GeoFilter GF4-3 EU8 >99% filtration at 0,3 µm –ø400
15-516
Filter G35 1/1 EU3 595x595x330 – 86% filtration*
15-517
Filter G50 1/1 EU5 595x595x650 – 95% filtration*
15-518
Filter G95 1/1 EU8 595x595x650 - >99% filtration*
*According to DIN24185
645
Installation example
Geofilter Dust
Pressure drop - GF4
[Pa]
Box fan MSFG 200-3
EU8
Spiro duct ø200
1100
1000
EU5
All curves = clean filter
900
800
Reduction 315/200
Geofilter Dust
EU3
700
Reduction 315/160
600
500
Spiro duct ø160
400
Slide damper ø160
300
Platsic bag
200
100
Belt grinder
500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500
Air Flow [m³/h]
Bench grinder
Dustbox CFU-1000
Art. No.
Description
The Dustbox CFU-1000 is a compact filter unit, well suited for extraction of particles from
grinding processes and more. 10 m² polyester filter cartridge, filtration efficiency of 99,9 % at
0,3µm. H: 880, W: 500mm, D: 500mm, inlet/outlet: 160mm nipple
· Max. air flow: 1.500 m³/h, recommended 1.000 m³/h.
· Well suited for grinding dust, welding smoke and more.
· Recommended end pressure drop before cartridge replacement: Max 1.800 Pa
· The ideal filter for smaller filtration needs but high demands for filtration efficiency.
15-100
15-101
15-102
15-103
Dustbox with fan.
38
15-104
15-105
Dustbox CFU-1000
Fan for Dustbox CFU-1000
with turbine wheel, 1,1kW, 3x400V, 50Hz, 2800 rpm
Soundproofing for Dustbox CFU-1000 (internal)
Automatic control til Dustbox CFU-1000 (motor guard, pressure
guardand more.)
Manual compressed air cleaning
Automatic compressed air cleaning
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
GeoFilter GFB - description
FILTER CARTIDGES
GeoFilter GFB comes with filtercartidges of differently pleated textiles, with
and without coating. (minimum filtering of 99,90% according to BIA-test)
FILTER CLEANING
The cleaing of the filter is automatic and is carried out with a shot of
compressed air through the cartridges.
This will cause the particles caught in the textile to fall in to the collection
bucket below for disposal.
FILTER REPLACEMENT
Unfasten the front and twist the cartridges from the bayonet mount.
INSTALLATION
Generally the filter should be placed indoors to avoid condensation.
However, if needed, the filter can be placed outside on account of the fully
galvanized housing. The filter requires a power supply of 230VAC and
3,5-5 Bar clean and dry compressed air.
The filter should not be used with a differential pressure higher than 3000 Pa.
FILTER AUTOMATICS
The GFB filter comes whith a user friendly filter control panel with digital display. Adjust the shot length (0-9 sek.), shot interval (1-999 sec.) and
GeoFilter GFB-3-1-FT/11
Legend
Filtertype
No. of shot valves
No. of cartridges
Compressed Air Air Consumption
3,5 - 5 bar
clean and dry Air
3,0 liter/min
per valve
after-run cycle (1-9 cycle).
Connects to 230 VAC 50 Hz. For differential pressure control we suggest
using Geovent AirBox. ( Optional)
Power Supply
Temperature
Typical
pressure drop
Sound level
Sealing class
24VDC or 230 VAC
-12°C - +65°C
1000-1500 Pa
<68 dB(A)
Class C
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
39
GeoFilter GFB - Filtration of 99,9% at 0,3 µm
Art. No.
Description
Filter area
Max m³/h
15-420
GeoFilter GFB-3-1
30 m²
1800
15-421
GeoFilter GFB-6-2
60 m²
3600
15-422
GeoFilter GFB-9-3
90 m²
5400
15-423
GeoFilter GFB-12-4
120 m²
7200
All GFB-filter is by default fitted with cartridge FT/11.
Other cartridge types available depending on the type of polluted air being filtered.
Note, different prices.
Note: The GFB filter is front operated only.
NEW: New control with differential pressure option - Art. No. 92-214
GeoFilter GFB HD - Filtration of 99,9% at 0,3µm.
Art. No.
Description
Filter area
Max m³/h
15-400-HD
GeoFilter GFB-3-1 HD
30 m²
1.050
15-401-HD
GeoFilter GFB-6-2 HD
60 m²
2.100
15-402-HD
GeoFilter GFB-9-3 HD
90 m²
3.150
15-403-HD
GeoFilter GFB-12-4 HD
120 m²
4.400
By default supplied with 1,5” shot valves for improved cleaning by diffifcult filtering proceses.
Shot valves for improved cleaning in case of heavy use.
PTFE Coated filter cartridges available.
By default supplied with timer control. Pressure control available on request.
Art. No.
15-490
Description
Water seperator for GFB filter with regulator, manometer
and mounting bracket.
Data for GeoFilter GFB
Model/Dimension [mm]
40
A
B
øD
Outlet
Weight, kg
Cabinet
GFB-3-1
775
325
ø250np
1x250np
90
Hot galv.
GFB-6-2
808
625
ø315np
1x315np
135
Hot galv.
GFB-9-3
850
925
ø400np
2x315np
180
Hot galv.
GFB-12-4
900
1225
ø500np
3x315np
225
Hot galv.
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Replacement cartridges for GFB – Filter area per cartridge: 10m²
Filter cartridges are selected according to the kind of air that needs filtration.
All GFB-filter is by default fitted with cartridge FT/11, a filter media designed for dust filled air
without smoke or oil mists.
Art. No.
Description
15-480FL
15-480A
15-481FL
FT/11 – 99,9% v/0,3µm (grinding dust / no smoke or oil mist)
FT/11 - 99,9% v/0,3µm ALUTEC (dust and smoke)
FT/13 – 99,9% v/0,3µm (welding smoke)
Additional charge for alu-coating - per filter cartridge
15-479
Pre-coat - ensures longer life for cartridge. Per liter.
(approx. 5 grams per m2)
15-440
For large amouts of dust:
Collection bucket w. wheels (98 l) and extended legs on filter
(New height: 2432mm).
Note: when ordering replacement cartridges, please state wheter the filter is
front- or top operated. (Older models could be top operated.)
Accessories for GeoFilter GFB HD
Art. No.
15-482
Description
FT/18 – 99,9% v/0,3µm (laser/plasma) PTFE membrane
Oil Mist
X
15-481FL
15-480A
03-260
HVU-it
03-259
HVU
03-260
HVU
15-482
15-108
Dustbox
Art. No.
15-480 FL
Application
15-351
Geovent Filter media use
X
Dry welding smoke
X
Oil saturated welding smoke
P*
Foundry
X
Zink
Powder Coating
X
X
X
X
Plasma/laser cutting
Sand blasting / Sand
X
P*
X
Sand blasting/ Glas
F*
Sand blasting / enamel, steel, aluminium
Grinding
Unspecified dust without smoke
X
X
X
X
X
X
X
X
X
Milk powder
X
Spice
A*
Tobacco
X
Paper
X
Chalk
X
Cement
X
Saw dust
A*
*Notes: P = Prekote
F = Moisture resistent
A = ATEX approved
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
41
42
Adjusting frequency inverter:
See manual - important parameters to adjust:
Motordata: Typically parameter group 99
Ramp up/down: Typically parameter group 22
Frequency Max/Min: Typically parameter group 20 and11
If the frequency inverter is to give signal to CTS the jumper on the bottom (S1)
must be switched from “I” to “U” This will change output from current to voltage. Remember to bridge GND and COM.
J
Adjusting Multibox II::
Quickguide - also see manual
P0: Version selector - select 530 (most common)
P1: Adjustment set point [Pa]
P2: Min. Alarm limits [s] at too low pressure
P3: Max. Alarm limit [s] at too high pressure
P10: shows current pressure.
230 V
N
N
0
230 V
CTS
J
0
3
3
L1
L1
L1
COM
DI1
DI2
8
9
400 V
PE
GND
Fi
R-
R+
7
U + V + W +PE
Start/Stop signal
Connect one of the
following frequency
inverters
Start/Stop signal
9 10
6
8
Alarm
MOTOR
+24V
4
GND
AI
2
3
SRC
ABB ACS 150
1
5
in Multibox
T10 is only used
2
2
4
Terminals
F
GFD Damper
1
1
N
5
J
Sensing coil
F F
Machine/welder
F
L
230V
N
230 V
1
Start/Stop signal
T10 is only used
in Multibox
DI1
DCOM
GND
+24V
GND
GND
AI1
SRC
400 V
L1
L1
L1
PE
Fi
R-
R+
ABB ACS 355
U + V + W +PE
12
11
10
9
8
3
2
1
2
3
GFD Damper
T2 - 24V out
GND
24V
AGND
AI1
SRC
13
DI1
10 11
400 V
L1
L1
L1
PE
Fi
R-
R+
ABB ACH 550
12 DCOM
11
10
9
3
2
1
NO
U + V + W +PE
Start/Stop signal
T10 is only used
in Multibox
NC C
CTS relay activated when
the box is
activated.
Machine/welder
One phase from the
welding plant is looped
through the sensing coil
Power coil connects to
10 and 11
PowerBox II
GND +24V +24V
START/STOP SIGNAL FOR FAN/MULTIBOX - connected in parallel
N
380 V
Power Smart
Note: If error, switch terminal 2 and 3 on freqency converter. This will typically solve the problam as 0V is sent in to AI
When T4 (floating input) is
activated the Multibox is
activated and CTS and
relay motor in the bottom
is activated.
Multibox II
When the filter is idle 14 and 15
MUST be connected to make
the cleaning cycle run when
the fan is not running.
14 and 15 must still be bridged.
During operation 12 and 13 must be
connected for the cleaning cycle to run.
Operation Relay for GFB Filter
Timer control on GFB Filter
MULTI COUPLING DIAGRAM - TERMINALS, GFB-FILTER, MULTIBOX AND FREQUENCY INVERTERS
Adjusting Multibox II:
Quick guide - also see manual
P0: Version selector - select 53
P1: Adjustment set point [Pa]
P2: Min. Alarm limits [s] at too l
P3: Max. Alarm limit [s] at too h
P10: shows current pressure.
IMPORTANT
If the fremquency inverter is to
CTS the jumper on the bottom
switched from “I” to “U”
This will change output from c
Remember to bridge GND and
Motor data: Typically paramet
Ramp up/down: Typically para
Frequency Max/Min: Typically
Adjusting the frequency inverte
See manual - important param
MULTI COUPLING DIAGRAM - TERMINALS, GFB-FILTER, MULTIBOX AND FREQUENCY INVERTERS
ERP 2015
20/20/20
As part of efforts to reduce CO2 emissions while
optimizing the way we use our resources, the EU has
issued a directive to withdraw products from the market unless they meet new energy efficiency requirements.
For fans, the requirements means they have to have an
effect between 125W and 500kW.
The EU directive sets out certain minimum fan´s
efficiency.
The efficiency requirements apply to assembled fans,
ie. motor, impeller and housing.
The Directive entered into force on January 1st. 2013,
and the requirements for energy efficiency will be
increased on January 1st. 2015.
In order to stay ahead and ensure that our customers
receive products which meet current and future
requirements , we have invested in our own test station
and also regularly send fans for tests in unbiased
laboratories in Germany.
In popular terms, the requirements are 20/20/20
- Use of renewable energy sources should increase by
20%
- This must be achieved by the year 2020.
- This will be achieved by making products 20%
more energy efficient.
For more information on the directive please visit:
http://ec.europa.eu/energy/efficiency/ecodesign/eco_
design_en.htm
F VAENNST I L ATO R E R
GEOVENT offers a wide range of fans with air flow up
to 24.000 m³/h.
In terms of pressure Geovent fans ranges wide,
up to 4.200 Pa.
Our fans are available as:
•
•
•
•
•
•
•
•
•
Central and decentral fans
Mobile, portable fans
Energy saving fans
Two-speed motor,
Motor with 6 and 8 poles
With frequency inverter
High temperature fans
Stainless or plastic
ATEX version
If you have special requirements, please do not hesitate
to contact us. At Geovent we are ready to do our best
to help you with your ventilation project.
We produce the fans ourselves on the Geovent factory
in Løgstrup, where we also keep a stock of intermediate goods such as fan housings, motors and wheels.
This means we offer high flexibility and fast delivery.
Most of our fans are made of galvanized steel to make
for long life.
GEOVENT centrifugal fans LSFG/MSFG
(with forward curved blads) and LEF/MEF
(with backwards curved blades) are used for
process extraction in industry or for comfort
ventilation.
The fan is made of 100% galvanized steel for
maximum corrosion resistance and therefore
suitable for outdoor installation on a roof or
wall. Our fans can be installed in a sound box to
reduce noise emission.
•
•
•
•
•
Feet with vibration dampers
cumstomised for the individual fan.
Inlet flange with mesh included.
Direct drive B5 flange motorprotection class IP-55.
Our fans are available with different accessories: sound box for noise
reduction, pressure connecting piece, rain shield, flexible connection, circuit breaker and pressure switch.
3 of the fan´s sides can be used as mounting flange.
A scirocco impeller (forward curved blades) is low
noise,
low vibration, delivers a high output per kW and
provides a relatively high pressure.
Due to the relatively flat curve of the scirocco impeller
it is not recommended for pressure regulation.
Some of the advantages of backward curved blades:
- efficiency of up to 87%
- well suited for pressure control causing for
substantial savings on operation.
Note: Most models are available in ATEX versions.
45
Fans LSFG/MSFG 146 to 250
G M S F G-180-3
Legend
Number of phases
Wheel Diameter mm
Galvanized
Flange motor B3
Scirocco wheel
Motor speed
M=2800 L=1400 rpm
Spark proof - EEX-e
Art. No.
Description
[kW]
[A]
Max
[m³/h]
Max [Pa]
38-001
38-002
38-003
38-004
38-005
38-006
LSFG-146-3
MSFG-146-3
GLSFG-146-3
GMSFG-146-3
LSFG-146-1
MSFG-146-1
0,25
0,55
0,25
0,55
0,25
0,55
0,84
1,42
0,79
1,43
1,9
3,49
700
900
700
900
700
900
160
620
160
620
160
620
30-001
30-002
30-003
30-004
30-005
30-006
LSFG-180-3
MSFG-180-3
GLSFG-180-3
GMSFG-180-3
LSFG-180-1
MSFG-180-1
0,25
0,55
0,25
0,55
0,25
0,55
0,84
1,42
0,79
1,43
1,9
3,49
1175
1670
1175
1670
1175
1670
230
950
230
950
230
950
31-001
31-002
31-003
31-004
31-005
31-006
LSFG-200-3
MSFG-200-3
GLSFG-200-3
GMSFG-200-3
LSFG-200-1
MSFG-200-1
0,55
1,1
0,55
1,1
0,55
1,1
1,58
2,52
1,59
2,6
3,93
6,51
1750
2100
1750
2100
1750
2100
320
1450
320
1450
320
1450
32-001
32-002
32-003
32-004
32-005
32-006
LSFG-225-3
MSFG-225-3
GLSFG-225-3
GMSFG-225-3
LSFG-225-1
MSFG-225-1
1,5
2,2
1,35
1,85
1,5
2,2
3,31
4,54
3,1
3,85
9,12
12,7
2500
2950
2500
2450
2500
2950
450
1500
450
1500
450
1500
33-001
33-002
33-003
LSFG-250-3
MSFG-250-3
GLSFG-250-3
2,2
4
2
4,83
7,56
4,65
3150
4900
3150
470
1840
470
33-004
GMSFG-250-3
3,3
6,9
3160
1800
Art. No.
Description
[kW]
[A]
Max
[m³/h]
Max [Pa]
33-203
33-202
MSKG-280-3
MSKG-280-3
5,5
7,5
10,3
14
4600
5800
2500
2700
34-001
34-003
34-203
34-204
LSKG-315-3
GLSKG-315-3
MSKG-315-3
MSKG-315-3
4
3,6
11
15
8,23
8,1
19,7
26,3
6000
6000
7900
10000
950
950
3400
3450
34-501
34-502
34-505
34-506
LSKG-355-3
GLSKG-355-3
MSKG-355-3
MSKG-355-3
4
3,6
22
37
8,23
8,1
38,1
63,5
8000
8000
10000
15000
1100
1100
5000
4900
35-001
35-003
LSKG-400-3
GLSKG-400-3
7,5
6,8
14,5
13,6
11500
10800
1900
1900
35-501
35-503
LSKG-450-3
GLSKG-450-3
11
10
21,6
18
12750
12000
2500
2500
Fans LSKG/MSKG 280 to 450
G L S K G-315-3
Legend
Number of phases
Wheel Diameter mm
Galvanized
Base motor B3
Scirocco wheel
Motor speed
M=2800 L=1400 rpm
Spark proof - EEX-e
46
Other motors on request.
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Pressure drop and sound data for Fans LSFG/MSFG 146 - 250
Fan
Ventilator
MSFG 146 - 250
550
1650
500
1500
450
1350
400
1200
Tryktab
Pressure
drop [Pa]
Pressure drop [Pa]
Fan LSFG 146 - 250
225
200
1050
350
250
300
250
225
200
150
200
180
100
50
250
180
900
750
600
450
300
146
150
146
300 600 900 1200 1500 1800 2100 2400 2700 3000 3300
500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500
Volumenstrøm
Air flow [m³/h]
Airflow [m³/h]
Noise Emission
Type
125 250 500 1000 2000 4000 8000 Lp, Lp,
Hz Hz Hz Hz Hz Hz Hz dB(A) 1m
125 250 500 1000 2000 4000 8000 Lp, Lp,
Hz Hz Hz Hz Hz Hz Hz dB(A) 1m
Type
LSFG 146
46
47
48
46
45
41
35
51
45
MSFG 146
61
62
65
63
64
58
51
69
63
LSFG 180
54
57
53
50
47
42
36
56
50
MSFG 180
70
80
69
64
65
59
54
74
68
LSFG 200
61
62
58
57
50
45
40
61
55
MSFG 200
80
83
72
71
71
66
61
78
72
LSFG 225
62
63
59
58
54
51
45
63
57
MSFG 225
82
85
75
73
74
68
63
81
75
LSFG 250
66
67
64
63
60
54
46
67
61
MSFG 250
86
90
77
75
76
71
65
84
78
Pressure drop for fans LSKG/MSKG 280 - 450
5500
2750
2250
4500
2000
4000
1750
400
1500
1250
355
1000
3500
3000
355 - 37 kW
315 - 15kW
315 - 11kW
280 - 7,5kW
2500
2000
280 - 5,5kW
1500
750
500
355 - 22kW
5000
450
Pressure drop [Pa]
Pressure drop [Pa]
2500
315
1000
500
250
1250 2500 3750 5000 6250 7500 8750 10000 11250 12500 13750
Airflow [m³/h]
1500 3000 4500 6000 7500 9000 10500 12000 13500 15000 16500
Airflow [m³/h]
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
47
Energy saving fan LEF/MEF 250 to 630 – B-impeller - efficiency up to 87%
Incl. inlet with safety mesh and
beam set with vibration insulation
B-wheel with backward curved blades.
G L E F -315-3
Legend
Number of phases
Wheel Diameter mm
Galvanized
Flange motor B5
B-wheel
Motor speed
M=2 poles L= 4 poles
Spark proof - EEX-e
48
Art. No.
Description
[kW]
[A]
Max[m³/h]
Max [Pa]
33-701
33-702
33-703
33-704
33-705
33-706
33-708
LEF-250-3
MEF-250-3*
MEF-250-3*
LEF-250-1
MEF-250-1
GLEF-250-3
GMEF-250-3
0,25
0,37
0,55
0,25
0,37
0,25
0,37
0,84
0,97
1,42
1,9
2,53
0,79
0,97
700
1650
1900
700
1400
700
1650
230
1200
1575
230
825
230
1200
34-651
34-652
34-653
34-654
34-655
34-656
34-657
34-658
LEF-315-3*
MEF-315-3*
MEF-315-3
MEF-315-3*
LEF-315-1
MEF-315-1
GLEF-315-3*
GMEF-315-3
0,25
0,55
0,75
1,1
0,25
0,75
0,25
0,75
0,84
1,42
1,86
2,52
1,9
4,62
0,79
1,76
1450
2600
2850
3200
1450
2850
1450
2850
360
1070
1330
1640
360
1330
360
1330
34-700
34-701
34-702
34-703
34-704
34-705
34-706
34-707
34-708
34-709
GMEF-355-3
LEF-355-3
MEF-355-3*
MEF-355-3*
MEF-355-3
MEF-355-3*
MEF-355-3*
MEF-355-1
LEF-355-1
GLEF-355-3
1,3
0,25
0,75
1,1
1,5
2,2
3
1,5
0,25
0,25
2,75
0,84
1,86
2,52
3,17
4,54
5,75
8,76
1,9
0,79
4350
2250
3350
3800
4350
5000
5500
4350
2250
2250
1550
425
1000
1240
1550
2150
2550
1550
425
425
35-201
35-202
35-205
LEF-400-3
LEF-400-1
GLEF-400-3
0,55
0,55
0,55
1,58
3,93
1,59
2500
2500
2500
500
500
500
35-203
35-204
35-206
35-206A
35-207
MEF-400-3*
MEF-400-1
MEF-400-3
MEF-400-3*
GMEF-400-3
2,2
2,2
4
5,5
4,1
4,54
12,7
7,56
10,3
8,1
3600
3600
6300
7500
6300
2150
2150
2150
2810
2150
35-701
35-702
35-703
LEF-450-3
LEF-450-1
GLEF-450-3
0,75
0,75
0,75
1,79
5,05
2
4700
4700
4700
700
700
700
35-705
35-706
35-707
35-708
MEF-450-3*
MEF-450-3
GMEF-450-3
MEF-450-3*
4
5,5
5,5
7,5
7,56
10,3
10,4
14
6000
9000
9000
10500
2600
2600
2600
3100
36-500
36-501
36-502
MEF-500-3
MEF-500-3*
MEF-500-3*
7,5
11
5,5
14
19,7
10,3
11400
12500
10000
3350
3950
2900
35-750
35-750A
35-751
35-752
35-753
35-755
35-756
MEF-630-3*
MEF-630-3*
LEF-630-3
LEF-630-3*
LEF-630-3*
LEF-630-3*
GLEF-630-3
22
15
4
7,5
11
5,5
3,6
38,1
26,3
8,23
14,5
21,6
10,9
8,1
24100
21500
14000
17000
18200
16200
14000
4500
3300
1600
2400
2650
2030
1600
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Pressure drop curves for energy saving fans LEF/MEF 250 to 400
Fan LEF / MEF-250
Ventilator
[Pa]
1625
1500
1560
n=3480
(2p - 61Hz)
83%
600
800
d
89
900
1200 1500 1800 2100 2400 2700 3000 3300
Fan LEF / MEF-400
n=3538rpm
(2p - 61Hz)
75%
82%
85%
)
(A)
A
B(
)
68%
dB
d
88
n=2915rpm
(2p - 50Hz)
2000
80%
)
1400
(A)
dB
A
B(
1600
51%
86
1800
n=2675rpm
(2p - 46Hz)
)
)
(A
dB
0,75kW
150
0,25kW
1000 1500 2000 2500 3000 3500 4000 4500 5000 5500
Air Flow [m³/h]
Volumenstrøm
800
600
400
50%
5,5kW
)
(A
dB
69
1,5kW
1,1kW
n=2150rpm
(2p - 37Hz)
79
2,2kW
1000
68%
(A)
A
B(
46%
75%
dB
84
)
(A
1200
3,0kW
500
600
0,37kW
0,25kW
Volumenstrøm
Air Flow [m³/h]
2200
600
300
0,75kW
0,55kW
)
90
A
B(
78%
d
79
750
48%
1,1kW
2400
dB
82
n=2240
(2p - 39Hz)
(A
)
2600
d
85
n=2507
(2p - 44Hz)
n=1460
(4p - 50Hz)
(2p - 25Hz)
300
2800
82%
59%
0,12kW
[Pa]
75%
1350
450
B(
A
130
1000 1200 1400 1600 1800 2000 2200
n=2860
(2p - 50Hz)
1200
64
d
n=1460
(4p - 50Hz)
(2p - 25Hz)
Air Flow [m³/h]
Volumenstrøm
1800
900
260
0,25kW
0,18kW
n=3277
(2p - 57Hz)
1500
)
0,37kW
n=3540
(2p - 62Hz)
2100
1050
390
Ventilator
Fan LEF / MEF-355
2400
72
dB
520
48%
0,55kW
(A
)
n=2010
(2p - 35Hz)
0,09kW
400
[Pa]
)
(A
57
dB
n=1460
(4p - 50Hz)
(2p - 25Hz)
200
A
B(
(A
)
375
125
d
79
650
71%
A)
70
B
500
250
780
n=2280
(2p - 40Hz)
(
dB
73
64%
n=2560
(2p - 45Hz)
n=2560
(2p - 45Hz)
dB
77
)
(A
910
A)
B(
625
n=2860
(2p - 50Hz)
80%
73
750
1040
dB
76
875
1170
76%
1000
n=2860
(2p - 50Hz)
1300
A)
1125
84%
1430
(
dB
79
1250
74%
n=3200
(2p - 56Hz)
1690
n=3995
69%
(2p - 70Hz)
)
(A
dB
81
1375
Ventilator
Fan LEF / MEF-315
[Pa]
n=1375rpm
(4p - 50Hz)
200
70
dB
4,0kW
(A)
2,2kW
1,1kW
0,37kW
750
1500 2250 3000 3750 4500 5250 6000 6750 7500 8250
Flow
Air Air
flow
[m³/h]
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
49
Pressure drop curves for energy saving fans LEF/MEF 450 to 630
Fan LEF / MEF-450
Ventilator
[Pa]
3250
2750
3600
86%
(
dB
94
A)
A)
600
2,2kW
300
0,75kW
1,1kW
1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000
Ventilator
Fan LEF / MEF-630
79% n=2600rpm
86%
(2p - 46 Hz)
)
(A
dB
97
3250
n=2300rpm
(2p - 41 Hz)
82%
74%
dB
n=1830rpm
(4p - 63 Hz)
)
(A
2000
n=2030rpm
(4p - 70 Hz)
92
2250
)
B(A
2500
d
94
3000
2750
62%
89
(
dB
15kW
A)
250
A)
500
52%
21 kW
(
dB
750
84
1000
n=1440rpm
(4p - 50 Hz)
86
1250
n=1584rpm
(4p - 55 Hz)
A)
1500
(
dB
1750
2,2kW
Volumenstrøm
Air Flow [m³/h]
3750
3500
7,5kW
5,5kW
4,0kW
1200 2400 3600 4800 6000 7200 8400 9600 10800 12000 13200
Air Flow [m³/h]
Volumenstrøm
4000
51%
11kW
)
(A
dB
80
n=1585
(2p - 27Hz)
900
4,0kW
[Pa]
A)
n=2120
(2p - 36Hz)
1200
5,5kW
68%
)
(A
dB
87
49%
A)
250
1500
7,5kW
(
dB
73
500
n=1395
(4p - 50Hz)
1800
76%
(
dB
90
62%
1000
750
2100
)
(A
dB
83
1250
n=2120
(2p - 36Hz)
n=2430
(2p - 42Hz)
2400
(
dB
92
1500
2700
74%
)
(A
dB
87
1750
81%
87%
82%
n=2690
(2p - 46Hz)
3000
A)
2000
n=2552
(2p - 44Hz)
)
(A
dB
89
2250
83%
n=2900
(2p - 50Hz)
3300
(
dB
92
2500
3900
81%
n=2900
(2p - 50Hz)
n=3300 77%
(2p - 57Hz)
(A)
dB
97
3000
n=3306 74%
(2p - 57Hz)
Ventilator
Fan MEF-500
[Pa]
11kW
7,5kW
5,5kW
4,0kW
2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000 24000 26000
Volumenstrøm
Air Flow [m³/h]
50
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Dimensions, fans LEF/MEF
G
H
I
J
K
M
N
Weight
230
210
460
**
170
320
637
185
38 kg*
290
240
460
**
210
400
720
225
43 kg*
284
329
272
460
**
234
450
797
250
48 kg*
308
367
304
760
**
260
500
965
275
56 kg*
500
340
408
340
760
**
290
560
1045
305
71 kg*
500
345
421
362
760
**
295
510
1065
263
81 kg*
630
446
563
467
760
**
400
800
1340
425
135 kg*
Type
A
B
C
D
E
F
250
410
500
500
315
510
550
600
250
215
315
260
355
570
655
400
648
800
680
400
756
400
450
715
500
758
800
850
800
871
630
989
800
1175
*/** - Depending on motor
ød
G L E F-400-3
6 x M6
I
Legend
Number of phases
5 x M8
Wheel diameter mm
Backward curved blades
Motor speed
M=2 poles L=4 poles
Spark proof - EEX-e
F
ø9
A
øD
M
Flange motor B5
L
G
H
B
C
N
J
48
1
4
E
M8
K
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
51
Dimensions for fans LSFG/MSFG 146 - 250 and LSKG/MSKG 280 - 450
LSFG/MSFG
LSKG/MSKG
ød
ød
6 x M6
6 x M6
I
I
5 x M8
L
A
øD
F
F
ø9
A
øD
M
5 x M8
B
L
G
H
B
C
G
C
N
M
N
J
E
J
1
4
E
H
M8
48
K
K
Dimensions Fans LSFG/MSFG 146 - 250
Type
A
B
C
D
E
F
G
H
I
J
K
L
M
N
Weight
L-/MSFG 146
245
400
295
160
145
134
113
360
178
95
185
27
402
118
12 kg
L-/MSFG 180
300
400
350
160
168
165
135
360
178
120
225
27
527
138
14 kg
L-/MSFG 200
350
400
400
200
180
205
165
360
205
130
250
27
577
150
18 kg
L-/MSFG 225
370
500
450
250
195
210
190
460
219
145
280
27
597
165
24 kg
L-/MSFG 250
410
500
500
250
215
230
210
460
300
170
320
27
637
185
38 kg
G
H
I
J
K
L
M
N
Weight
Dimensions Fans LSKG/MSKG 280 - 450
Type
52
A
B
C
D
E
F
MSKG 280
455
515
545
315
235
260
215
235
374
185
325
680
303
9
87 kg
LSKG 315
510
550
600
315
260
290
240
190
335
210
400
472
269
11
63 kg
GLSKG 315
510
550
600
315
260
290
240
190
335
210
400
472
269
11
63 kg
MSKG 315 - 11,0kW
510
570
600
315
260
290
240
190
478
210
400
472
328
11
125 kg
MSKG 315 - 15,0kW
510
570
600
315
260
290
240
190
478
210
400
472
328
11
143 kg
LSKG 355
570
655
680
400
284
329
272
190
335
234
450
770
285
11
91 kg
LSKG 400
650
687
760
400
310
370
305
300
374
260
500
945
305
11
105 kg
LSKG 450
715
915
850
500
340
408
340
354
478
290
560
1045
369
15
111 kg
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Sound boxes for fans
Art. No.
Description
30-070
Sound box 146/180 (Suitable for both sizes.)
31-070
Sound box 200
32-070
Sound box 225
33-070
Sound box 250
34-070
Sound box 280/315 (not MSK 315, use: 35-570)
34-570
Sound box 355 (not MSK 355, use 35-070)
35-070
Sound box 400
35-570
Sound box 450
36-570
Sound box 500
35-870
Sound box 630
Protects against wind and weather - Noise reduction 8 - 10 dB
Dimensions, Sound boxes
Dimensions, Sound boxes - all measurements in mm
146/
180
200
B
470
H
405
L
720
øD
160
E
P
Type
280/
315
355
400
450
500
630
620
715
800
885
975
1000
1300
510
615
672
750
820
860
1095
915
1010
1160
1366
1470
1840
1845
1800
250
250
315
400
400
500
500
630
260
307
334
385
410
430
545
310
357
400
450
480
490
645
465
510
580
683
730
925
927
880
225
245
285
310
335
368
323
488
215
240
280
308
330
365
370
470
225
250
520
570
455
475
820
200
205
230
240
230
260
285
M
362
410
J
200
210
C
190
200
I
Weight
105
105
105
105
105
100
105
105
100
100
26kg
32kg
38kg
45kg
61kg
85kg
114kg
148kg
156kg
190kg
Tryktuts
Outlet
flange
H
I
C
J
E
P
øD
M
B
L
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
53
Accessories for fans
Art. No.
54
Description
38-009
Outlet flange 146/ø80
38-015
Outlet flange 146/ø125
38-021
Outlet flange 146/ø160
30-015
Outlet flange 180/ø160
30-019
Outlet flange 180/ø200
31-015
Outlet flange 200/ø200
31-015A
Outlet flange 200/ø250
31-015B
Outlet flange 200/ø315
31-019
Outlet flange 200/ø160
32-015
Outlet flange 225/ø250
32-019
Outlet flange 225/ø200
32-021
Outlet flange 225/ø315
33-015
Outlet flange 250/ø250
33-019
Outlet flange 250/ø200
33-021
Outlet flange 250/ø315
33-515
Outlet flange 280/ø315
33-519
Outlet flange 280/ø400
34-015
Outlet flange 315/ø315
34-023
Outlet flange 315/ø400
34-515
Outlet flange 355/ø400
34-519
Outlet flange 355/ø315
35-015
Outlet flange 400/ø400
35-019
Outlet flange 400/ø500
35-021
Outlet flange 400/ø630
35-519
Outlet flange 450/ø400
35-515
Outlet flange 450/ø500
35-521
Outlet flange 450/ø630
36-515
Outlet flange 500/ø500
36-519
Outlet flange 500/ø630
35-775
35-776
Outlet flange 630/ø630
Outlet flange 630/ø800
Other sizes on request.
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Accessories for fans
Art. No.
Description
38-060
Rain cover 146
30-060
Rain cover 180
31-060
Rain cover 200
32-060
Rain cover 225
33-060
Rain cover 250
33-260
Rain cover 280
34-060
Rain cover 315
34-560
Rain cover 355
35-060
Rain cover 400
35-560
Rain cover 450
36-560
Rain cover 500
35-780
Rain cover 630
07-150
Wall Bracket 146 til 200 (2-piece set.)
07-151
Wall Bracket 225 til 250 (2-piece set.)
07-152
Wall Bracket 280 til 355 (2-piece set.)
07-153
Wall Bracket 400 til 450 (2-piece set.)
07-154
Wall Bracket 500 til 630 (2-piece set.)
07-068
Roof console GB 15-45°
07-069
Roof console 0-5°
92-200
Manual circuit breaker - adjustment range: 0,4-0,63 A
92-201
Manual circuit breaker - adjustment range: 0,63-1,00 A
92-202
Manual circuit breaker - adjustment range: 1,00-1,60 A
92-203
Manual circuit breaker - adjustment range: 1,60-2,50 A
92-204
Manual circuit breaker - adjustment range: 2,50-4,00 A
92-205
Manual circuit breaker - adjustment range: 4,00-6,30 A
92-206
Manual circuit breaker - adjustment range: 6,00-10,0 A
92-207
Manual circuit breaker - adjustment range: 9,00-14,0 A
92-208
Manual circuit breaker - adjustment range: 13,0-18,0 A
92-209
Manual circuit breaker - adjustment range: 17,0-23,0 A
92-210
Additional charge for breaker switch for canceling
process monitor/pressure switch.
07-160
Flexible connection ø160
07-161
Flexible connection ø200
07-162
Flexible connection ø250
07-163
Flexible connection ø315
07-164
Flexible connection ø400
07-165
Flexible connection ø500
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
55
ESV
Energy saving fans with EC motors
ESV-energy saving fan with the newest EC-motors up to
10% more energy efficient than an IE1-motor.
This fan lives up to the EU requirements for IE3 efficiency class which enter into force in 2015.
The ESV-energy saving fan can be regulated stepless with
a pot-meter or be controlled by differential pressure
with GEOVENT Multibox without the use of frequency
inverter.
The fan is fitted with a plastic wheel with backward
curved blades.
It is supplied mounted in a galvanized soundbox with
50 mm insulation.
The ESV-energy saving fan is well suited for both comfort ventilation and process extraction
Air flow up to 7.650 m³/h and an available pressure of
up to 1.750 Pa.
Dimensions
A
øB
øA
D
B
56
C
A
B
C
D
øA
øB
Weight
ESV31/35
ESV40/45
734
758
738
455
400
400
89kg
825
848
828
545
400
400
95kg
Energy saving fans, ESV (box)
Art. No.
Description
[kW]
[A]
Max [m³/h]
Max [Pa]
39-270
39-271
39-272
39-273
39-278
39-274
39-275
39-276
39-276A
39-277
39-277A
ESV35-PLA-1
ESV45-PLA-1
ESV35-PLA-3
ESV45-PLA-3
ESV45-PLA-3
ESV31-ALU-1
ESV40-ALU-1
ESV31-PLA-3
ESV31-PLA-3
ESV40-ALU-3
ESV40-PLA-3
0,87
0,75
1,25
1,45
5,6
1,35
1,25
2,5
3,9
1,95
3,9
4,5-3,2
3,9-2,8
2,1-1,65
2,5-2,0
9,0-7,1
6,9-5,0
6,2-4,5
4,0-3,2
6,2-5,0
3,3-2,6
6,2-5,0
4400
5750
5200
7300
11000
4750
6500
6200
7100
7650
9800
800
550
1050
900
2200
1250
850
1800
2400
1200
1700
Pressure drop curves and dimensions for ESV Energy saving fans
ESV35-PLA-1 (Plastic wheel- 1x230V)
ESV35-PLA-3 (Plastic wheel - 3x400V)
ESV45-PLA-1 (Plastic wheel - 1x230V)
ESV45-PLA-3 (Plastic wheel - 3x400V)
Coupling diagram for energy saving fans
ESV31-PLA-3 (Plastic wheel - 3x400V)
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
57
Plastic fans.
GEOVENT plastic fans are suitable for extraction in corrosive environments e.g. laboratories, battery rooms, chemical cupboards and more.
Both fan house and wheel is constructed in heavy duty polypropylene (PP).
Air flows up to 6.700 m³/h and an available pressure of up to 1.700 Pa.
Art. No.
Description
[kW]
[A]
[rpm]
38-104x
38-106
LPX-125
MPV 202
0,09
0,18
0,85
0,49
1350
2750
Max [m³/h] Max [Pa]
100
80
1080
470
38-108
38-110
LPV 254
MPV 252
0,12
0,37
0,42
0,87
1370
2820
1080
2100
160
750
38-112
38-114
LPV 284
MPV 282
0,18
0,75
0,58
1,66
1370
2820
1500
3360
240
1100
38-116
38-118
LPV 314
MPV 312
0,25
1,5
0,8
3,15
1400
2850
2100
4260
290
1320
38-120
38-122
LPV 354
MPV 352
0,37
2,2
1,13
4,4
1400
2870
3000
6720
380
1700
38-124
38-126
RPV 406
LPV 404
0,25
0,55
1
1,75
920
1420
2.700
4.260
240
520
38-130
RPV 456
0,37
1,25
920
3780
290
38-132
LPV 454
1,1
2,6
1420
6000
650
Plastic fans are available in 1-phase versions and ATEX versions. Enquire for prices.
Fan
Fan
Air flow
Air flow
Fan
Air flow
58
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Dimensions Plastic fans
Type
Motor
Rpm
kW
A
B
C
E
G
H
I
D
D1
L
M
N
O
d
kg dB(A)
MPV 202
2750
0,18
398
370
140
340
218
250
75
160
160
195
245
100
150
10
10
62
MPV 252
2820
0,37
478
465
183
390
250
310
90
200
200
252
302
100
150
10
12
71
MPV 282
2820
0,75
555
520
208
422
300
350
95
225
225
277
327
120
170
10
22
75
MPV 312
2850
1,5
600
580
240
445
320
410
100
250
250
315
365
150
200
10
31
79
MPV 352
2870
2,2
552
640
260
490
340
445
110
280
280
345
395
150
200
10
38
80
LPV 254
1370
0,12
478
465
183
370
250
310
90
200
200
252
302
100
150
10
10
54
LPV 284
1370
0,16
555
520
208
380
300
350
95
225
225
277
327
120
170
10
17
55
LPV 314
1400
0,25
600
580
240
410
320
410
100
250
250
315
365
150
200
10
23
59
LPV 354
1400
0,37
652
640
260
430
340
445
110
280
280
345
395
150
200
10
28
61
LPV 404
1420
0,55
726
723
290
472
374
495
120
315
315
465
515
170
220
10
38
69
LPV 454
1420
1,1
792
810
324
510
400
550
133
355
355
510
560
170
220
10
48
70
RPV 316
930
0,18
600
580
240
410
320
410
100
250
250
315
365
150
200
10
20
50
RPV 356
930
0,18
652
640
260
430
340
445
110
280
280
345
395
150
200
10
22
53
RPV 406
920
0,25
726
723
290
450
374
495
120
315
315
465
515
170
220
10
34
56
RPV 456
920
0,37
792
810
324
497
400
550
133
365
355
510
560
170
220
10
37
59
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
59
Fan for direct mounting on hose reel type LX and FB and on WING and COMPACT arms
Art. No.
Description
31-209
Fan MSQ-200-3 0,75kW, 3x400V, 1.400 m³/h - 1,86A
31-208
Fan MSQ-200-1 0,75 kW, 1x230V, 1.400 m³/h - 4,62A
31-019
Connection piece 200/ø160 reduction. Fan outlet for MSQ-200
04-460A
Mounting bracket for hose reel FB and LX (factory mounted).
For mounting Fan MSQ directly on the side of a hose reel.
31-201
Adaptor for monting on wall console for ø160 arme
31-207
Adaptor for monting on wall console for ø200 arme
Fans MHF 400 to 500 - with closed wheel with backward curved blades
Centrifugal fan with closed wheel with backward curved blades and direct driven flange motor.
The MHF-fan is used for industrial process extraction.
The MHF fan delivers a high pressure and is therefore ideal for
PID/constant pressure regulation.
Art. No.
Description
[kW]
[A]
[m³/h]
Max [Pa]
35-450
MHF-400-3
1,1
2,52
1300
2500
36-550
MHF-500-3
4
8,23
2600
4000
Ventilator
MHF-400-3
Fan
2900 Rpm
[Pa]
4200
3900
MHF-500
3600
3300
3000
2700
2400
2100
1800
1500
1200
900
MHF-400
600
300
250
500
750
1000 1250 1500 1750 2000 2250 2500 2750 3000
Volumenstrøm
Air flow [m³/h]
60
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Portable, mobile fans
For several years GEOVENT has delivered portable and mobile ventilation and extraction solutions for use on board ships, off shore, in farming, for service engineers and industry.
Common to all the tasks is that it is difficult and some times impossible to establish a fixed
point of extraction as the tasks are where the operator is working.
E.G. welding jobs on building material, paint jobs, or repair work on board ships or oil rigs.
The outlet hose is placed outside so the operator is not exposed to hazardous fumes, smoke or
particles.
Note: Recirculation is not always in compliance with local regulation.
Therefore we recommend using a hose on the fan outlet and place it outside.
Art. No.
Description
PM-180-1
[kW]
[A]
Max
[m³/h]
Max [Pa]
0,55kW
3,93
1400
950
30-006A
Including 10 m ø125mm P2A1000 hose,nozzle with magnet, thermal
protection with breaker and 10 m cable 1x230V with plug.
Air flow up to 700m³/h, and less if the hose is bent.
30-006H
Including 10 m ø160 mm P2A1000 hose, nozzle with magnet, thermal protection with breaker and 10 m cable 1x230V with plug.
Air flow up to 1100m³/h, and less if the hose is bent.
30-007
Additional charge for transport cart.
09-310A
Extra 10 m hose with MF/NP quick coupling, ø125mm
09-313H
Extra 10 m hose with MF/NP quick coupling, ø160mm
Mobile extractor designed for various extraction tasks where filtering of the extracted air is
needed.: windscreen gluing, welding and extraction of exhaust gases.
The arm is selected according to the type of job for which it is going to be used.
The mobile filter unit is available with a quick coupling system which makes it more flexible
and suitable for various purposes.
Art. No.
15-200
Description
W3 Filter Unit 1,1kw 1x230V
01-008M
WING-arm ø160mm 2,0m Table version -suitable for mobile extractor
01-009M
WING-arm ø160mm 3,0m Table version -suitable for mobile extractor
Mobile extractor with fixed extraction arm
Very suitable for tasks like painting, gluing and other jobs involving organic solvents.
Highly portable and easy to lift from a van.
Complete set with 1m ø125 mm Flexi arm, with transparent polycarbonate hood, 1,1kw motor for 1x230V with 10m cable, spark safe inlet and10m outlet hose ø160.
Max airflow: 400-700m³/h.
Art. No.
01-590
Description
Mobile extractor MVF-125-1
Mobile extractor with fixed ASA3-extraction arm.
To be used in for example repair shops where a fixed arm is inconvenient.
Powdercoated black steel with wheels and low center of gravity.
Height (without arm): 1700mm
Complete set with MSFG-200-3 fan, 3x400V with 10m cable, ASA3-arm ø160 and 5m. outlet hose.
Art. No.
Description
10-270-2W
Mobile extractor with 2 m. ASA arm
10-270-3W
Mobile extractor with 3 m. ASA arm
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
61
AUTOMATICS
GEOVENT offers a wide range of options for ventilation
and extraction controls.
•
Air Box II - Statutory alarm device – lives up to the requirements of the Danish Working
Environment Authority and alerts the user if an error in the ventilation system should occur.
•
Powerbox II - Automatic start/stop of the fan
- Increases comfort for operator and energy efficiency.
•
Multibox II - Pressure-controlled airflow makes sure the extraction is always at the correct level and thus reducing
energy consumption significantly.
62
I ME IRZEETD UEDXSTURGANC ITNI O
OOP PT ITM
GN
%
Energy saving automatics
Example of power consumption
100
90
Save money on electricity and heating
80
Studies show that most point extraction installations
electricity and heating. Normally the investment pays
30
itself back in 1 - 3 years.
20
10
Conventional fan
40
Geovent offers several solutions helping you to save on
Energy
conserving
fan with
pressure &
start/stop
control
50
by optimizing use of the installation.
Energy conserving
fan with start/stop
control
Unregulated high efficiency fan
60
working day. As a result there are substantial savings
Conventional fan with start/stop
control
70
are only used efficiently 5 - 20 % of the time during a
Fast action motor damper - GFD
Normal motor dampers does not turn fast enough
for use with point extraction as the pollution starts
instantly.
Geovents GFD fast turning damper opens in just one
second and secures instant and efficient extraction.
24 V AC/DC On/off or modulating via 0-10V trafo or
Powersmart/Powerbox.
Control type
1 Point of extraction
Exhaust gas
Welding smoke
Grind dust
oil mist
Start/stop
Start/stop
Start/stop
Start/stop
2-4 Points of ext.
Start/stop
Pressure control
Start/stop
Start/stop
5-8 Points of ext.
Start/stop
Pressure control
Pressure control
Pressure control
9-12 Points of ext.
Start/stop
Pressure control
Pressure control
Pressure control
> 12 Points of ext.
Pressure control
Pressure control
Pressure control
Pressure control
63
F re
N FVOE R TMEERRSE
F RQ
E KUVE ENNCSYOIM
At Geovent we distribute high quality frequency
inverters from ABB. Due to their very user-friendly
installation and set-up process they are ideal for use
with our fans and MultiBox II.
We offer ABB frequency inverters at competitive prices
and at the same time we give you advice on use and
connection options.
We have 3 different models in our range.
ASC-150 is the budget model with fewer options than
larger models but still very capable.
Suitable for pressure regulation with Geovent Multibox II.
Built-in display and pot-meter in the front.
ACS355 is the middle range model, with a wide range
of connection options. Very suitable for pressure controlled regulation with Geovent MultiBox II.
A choice of programming panel in the front (standard
or Assistant). The Assistant panel is optional and guides
you through the adjustment of the different parameters.
ACH550- top model with Assistant panel by default.
Extensive programming and connection options.
The models are available in three different enclosure
classes from IP20 to IP54, and in 1 or 3 phase versions.
Please enquire for further information.
64
M U L T I BMOultib
X II ox II
PROVEN DESIGN
GEOVENT MultiBox II is a 4th generation control based on the latest
microprocessor technology.
SEVERAL OPTIONS IN ONE BOX
GEOVENT MultiBox II can be used for pressure gauging, control,
regulation and alarm surveillance in installations for process ventilation
in the pressure range 10-5000 Pa.
EASY TO USE
MultiBox II is particularily suitable for dynamic pressure regulation in
installations with regulation dampers and/or with fans with frequency
inverters.
The desired pressure or flow (differential pressure) is entered as
set-point, and the built-in regulator will adjust damper or frequency
inverter. If the regulation does not maintain pressure or flow within the
predefined limits, the alarm is activated.
Green cable:
Controls and supply power to energysaving damper via built-in power supply in
PowerBox.
MEF-450-3
Fan in sound box with ABB
frequency inverter.
Blue cable:
Shielded cable for sensing coil which
is built-in to power outlet - Senses if
welding plant is in use and gives signal
to PowerBox which opens the energy
saving damper.
PowerBox:
Starts and stops fan,
MultiBox II and motor
damper.
230V Supply Voltage
400V supply to til
CEE-outlet
MultiBox II:
Monitors pressure in duct
system.
Note: PowerBox and
CEE-plug can be
replaced by
PowerSmart (see this )
Red Cable:
Start/stop of fan as
function of sensing coil.
Yellow Cable:
Analogue 0-10V signal
stepless regulation of fan.
Opaque suction tube:
Measures low pressure
(10-5000 Pa) in duct system
via pressure transducer i
Multibox II
24V Fast Action Damper
0-90° in 1 second.
Wing-arm
ø160x3m with wall console
65
66
L
L1
2
1
3
3
4
3
Multibox II
START/STOP SIGNAL FOR
FAN/MULTIBOX
N
230 V
J
0
4
5
CTS
6
9 10
Start/Stop signal
8
Alarm
When T4 (floating input) is
activated the Multibox is
activated and CTS and
relay motor in the bottom
is activated.
Start/Stop signal
in Multibox
T10 is only used
Connect one of the
following frequency
inverters
Contact set.
2
1
LX Hose Reel
T1 T2 T3 T4 T5 T6 T7 T8 T9 T10
GFD Damper
2
1
GFD Power
N
Note: Bridge
L and L1
230 V 230 V
L
L1
Note: Bridge
L and L1
2
2
SRC
AI
GND
2
3
L1
L1
COM
DI1
DI2
7
8
U + V + W +PE
380 V
L1
GND
6
9
PE
+24V
5
Fi
R-
R+
ABB ACS 150
1
4
3
3
GFD Damper
1
1
GFD Power
N
230 V
Start/Stop signal
in Multibox
T10 is only used
GND
+24V
GND
GND
AI1
SRC
12 DI1
2
2
3
3
5
Start/Stop signal
in Multibox
T10 is only used
4
Terminals
F
N
J
380 V
F
Sensing coil
F
GND
24V
AGND
AI1
SRC
DI1
U + V + W +PE
13
380 V
L1
L1
L1
PE
Fi
R-
R+
ABB ACH 550
12 DCOM
11
10
9
3
2
1
Machine/welder
F
Power Smart
GFD Damper
1
1
N
380 V
L1
L1
L1
PE
Fi
R-
R+
ABB ACS 355
11 DCOM
10
9
8
3
2
1
U + V + W +PE
4
3
Contact set
2
1
FB Hose Reel
MULTI COUPLING DIAGRAM - TERMINALS , MULTIBOX AND FREQUENCY INVERTERS
L
L1
Note: Bridge
L and L1
2
2
3
3
Etc.
Functions:
Black/blue=Connect
Black/grey=break
Terminals: Max.
external connection
250V, 6 Ohms
NC - Grey
Adjusting Multibox II:
Quick guide - also see manual
P0: Version selector - select 530 (most common)
P1: Adjustment set point [Pa]
P2: Min. Alarm limits [s] at too low pressure
P3: Max. Alarm limit [s] at too high pressure
P10: shows current pressure.
IMPORTANT
If the fremquency inverter is to give signal to
CTS the jumper on the bottom (S1) must be
switched from “I” to “U”
This will change output from current to voltage.
Remember to bridge GND and COM.
,
Motor data: Typically parameter group 99
Ramp up/down: Typically parameter group 22.
Frequency Max/Min: Typically parameter group 20 & 11
Adjusting the frequency inverter:
See manual - important parameters to adjust:
GFD Damper
1
1
NO - Blue
Common
- (Black)
Micro Switch
GFD Power
N
230 V
Multi coupling diagram for terminals, MultiBox and frequeny inverters
Automatics
Art. No.
Description
13-700
The MultiBox II is suitable for pressure regulation (PID), measuring, control and monitoring (with alarm) of a system for process
ventilation.
Choose range: 10-1000 Pa or 10-5000 Pa. 3 outputs and three
inputs in sum box.
Capable of controling several fans and regulate after 3 set points.
13-710
AirBox II 10-5000 Pa ventilation monitor with built-in pressure
transmitter, monitoring and alarm for process extraction.
Complies with the requirements of the
Danish Working Environment Authority.
13-730
AirBox Lite 500-2000 Pa ventilation guard,
monitoring and alarm for process extraction.
Comply with the requirements of the Danish Working Environment
Authority. Red and green conrol light, no siren
13-728
AirBox Lite 20-300Pa.
13-729
AirBox Lite 100-1000Pa.
13-102
Suction tube with mounting kit. - 10 m ø6 mm
13-080
Red external alarm light1x230V
13-081
External siren1x230V – 100 dB(A)
To be used for multiple rooms
Power Smart II - for the connection of welding plant. Sends a signal to the damper, when
the arc is turned on.
Incl. self-adjusting, active flux sensor = immune to noise. Suitable for new installations.
2 x relay output and 24V transformer
13-059
13-058
13-058A
Power Smart II CEE 16A
Power Smart II CEE 32A
Power Smart II CEE 63A
PowerBox II - for start/stop of fan and GFD motor damper.
The PowerBoxe is supplied with 3 inputs which can be connected to sensing coils.
18W 24VDC power supply for GFD motor damper.
13-057
Powerbox II, Sensing coil not included
13-047
Sensing coil for PowerBox. Register if welding plant, angle grinder or
other equipment is in use and signals the PowerBox.
The connected equipment must have a power consumption in excess
of 700W.
13-047A
Flux sensor for Powerbox.
Must be used with equipment that does not comply with the EMC
Directive.
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
67
Automatics
Art. No.
Description
19-100
Control panel LWS 225 – 12 input terminals max 0,55-2,2kW
19-101
Control panel LWS 250 – 12 input terminals max 4,0-5,5kW
19-102
Control panel LWS 280 – 20 input terminals max 7,5kW
19-103
Control panel LWS 315 – 20 input terminals max 11,0kW
Fan starter incl. motor guard and 24V power supply are customizable.
External ABB Frequency inverters
Art. No.
Description
Affordable external frequency inverter incl. EMC radio noise filter.
Built-in display and pot meter in the front
19-160
ACS 150 1x230V 0,37kW IP20
19-161
ACS 150 1x230V 0,75kW IP20
19-162
ACS 150 1x230V 1,1kW IP20
19-163
ACS 150 1x230V 1,5kW IP20
19-164
ACS 150 1x230V 2,2kW IP20
19-165
ACS 150 3x380-480V 0,37kW IP20
19-166
ACS 150 3x380-480V 0,55kW IP20
19-167
ACS 150 3x380-480V 0,75kW IP20
19-168
ACS 150 3x380-480V 1,1kW IP20
19-169
ACS 150 3x380-480V 1,5kW IP20
19-170
ACS 150 3x380-480V 2,2kW IP20
19-171
ACS 150 3x380-480V 3,0kW IP20
19-172
ACS 150 3X380-480V 4,0kW IP20
Mid range external frequency inverter incl. EMC radio noise filter.
Note: Control panel not included
68
19-200
ACS 355 1x230V 0,37kW IP20
19-201
ACS 355 1x230V 0,75kW IP20
19-202
ACS 355 1x230V 1,1kW IP20
19-203
ACS 355 1x230V 1,5kW IP20
19-204
ACS 355 1x230V 2,2kW IP20
19-205
ACS 355 3X380-480V 0,37kW IP20
19-206
ACS 355 3X380-480V 0,55kW IP20
19-207
ACS 355 3X380-480V 0,75kW IP20
19-208
ACS 355 3X380-480V 1,1kW IP20
19-209
ACS 355 3X380-480V 1,5kW IP20
19-210
ACS 355 3X380-480V 2,2kW IP20
19-211
ACS 355 3X380-480V 3,0kW IP20
19-212
ACS 355 3X380-480V 4,0kW IP20
19-213
ACS 355 3X380-480V 5,5kW IP20
19-214
ACS 355 3X380-480V 7,5kW IP20
19-215
ACS 355 3X380-480V 11kW IP20
19-216
ACS 355 3X380-480V 15kW IP20
19-217
ACS 355 3X380-480V 18,5kW IP20
19-218
ACS 355 3X380-480V 22kW IP20
19-280
Assistant panel
19-281
Basic panel
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
External ABB Frequency inverter, continued.
Art. No.
Description
High End external frequency inverter incl. EMC radio noise filter, incl. Assistant control panel
19-242
19-243
ACH 550 3X380-480V 30kW IP21
ACH 550 3X380-480V 37kW IP21
19-250
ACH 550 3X380-480V 0,75kW IP54
19-251
ACH 550 3X380-480V 1,1kW IP54
19-252
ACH 550 3X380-480V 1,5kW IP54
19-253
ACH 550 3X380-480V 2,2kW IP54
19-254
ACH 550 3X380-480V 3,0kW IP54
19-255
ACH 550 3X380-480V 4,0kW IP54
19-256
ACH 550 3X380-480V 5,5kW IP54
19-257
ACH 550 3X380-480V 7,5kW IP54
19-258
ACH 550 3X380-480V 11kW IP54
19-259
ACH 550 3X380-480V 15kW IP54
19-260
ACH 550 3X380-480V 18,5kW IP54
19-261
ACH 550 3X380-480V 22kW IP54
19-262
19-263
ACH 550 3X380-480V 30kW IP54
ACH 550 3X380-480V 37kW IP54
Accessories for frequency inverter and EC-motors (ESV)
Art. No.
Description
19-284
Protection kit for frequency inverter ABB-ACS-150
The frequency inverter can now be placed indoors outside
control box.
97-001
External pot meter. Speed adjustment: 0-100%
19-285
Steel wall cupboard for ACS150 400x300x200 mm. (HxWxD)
With noise insulation for the frequency inverter.
Incl. cooling fan and mesh.
19-286
Steel wall cupboard for ACS355 500x400x250mm. (HxWxD)
Incl. cooling fan and mesh.
Other pot meters on request.
Motor Damper 24V (0 to 90° = 1 sec.)
Art. No.
Description
61-091
Motor Damper GFD-80
61-092
Motor Damper GFD-100
61-093
Motor Damper GFD-125
61-094
Motor Damper GFD-160
61-095
Motor Damper GFD-200
61-096
Motor Damper GFD-250
(Quick action: on/off or modulating)
61-046
Power supply 230V / 24V for GFD Motor Damper
Motor Damper ( 0 to 90° = 30 sec. )
Art. No.
61-082
61-083
61-081
61-084
61-085
61-104
61-105
61-088
Description
Motor Damper, 220V ø80 Tight
Motor Damper, 220V ø100 Tight
Motor Damper, 220V ø125 Tight
Motor Damper, 220V ø160 Tight
Motor Damper, 220Vø200 Tight
Motor Damper, 220V ø250 Tight
Motor Damper, 220V ø315 Tight
Motor Damper, 220V ø400 Tight
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
69
H igh
unit
H Ø Jvacuum
VAKUUMA
NLÆG
GEOVENT High Vacuum Unit can be supplied as a
complete unit or as seperate modules.
Geovent HVU is ideal when particles are to be removed
from the polluting process, for example at vacuuming
and grinding job in the industry, repairshops or hotels
where the separated particles must be collected and
disposed of.
GEOVENT High Vacuum Unit is produced with high
quality European components and is supplied complete with filter cartridge or filter cyclone, cleaning
system with compressed air and control by request.
HVU - Complete unit with
combined filter cyclone and
module with side channel blower.
Geovent´s modular High Vacuum system is
composed and designed specifically for the job at hand.
Typically a High Vacuum System consists of:
•
•
•
HVU Solo with side channel blower
Filter cyclone
Control panel.
A preseparator can be added to seperate the largest
particles prior to reaching the filter cartridge.
Geovent carry a wide range of accessories for our High
Vacuum Units including hoses, tubes, valves
and energy satellites.
HVU Solo.
Stand-alone module with
side channel blower.
70
HVU Lite - 99,9% w. manual(1-push) pneumatic filter cleaning
Complete High Vacuum Unit with filter cyclone for extraction of dust from
grinding processes, brake dust and work station cleaning. The unit is supplied
with 99,9% antistatic filter cartridge of 7,5 m², collection bucket of 25 litres
and bush-button filter cleaning. HVU Lite suitable for use in up to
6 hours a day from 1 – 4 outlets.
[m³/h]
v/ 0 Pa
[kPa]
Max
550
21 kPa
Art. No.
Description
03-802
HVU Lite 55
03-820
Additional charge for Fully automatic pneumatic cleaning.
03-821
Additional charge for automatic start/stop-control panel
03-810
Vacuum protection for side channel blower
(overload protection) •
•
•
•
[kW]
5,5
[Volt]
3 x 400
Dimensions: Height x Width x Depth = 1200 x 550 x 1000mm
Connection: ø80mm inlet on the front of the cyclone/ ø80mm outlet on the top.
Noise level: 74db(A)
Compressed air: 3,5 Bar clean and dry air.
HVU – w. fully sutomatic pneumatic filter cleaning, 99,9% at 0,3µm
Geovent High Vauum Unit HVU (over 20 kPa) Suitable for vacuuming at pre-sale
preparation of cars, grinder dust or in connection with energy arms.
The unit is supplied with a two-step filter cyclone with an efficiency of 99,9%
and fully automatic pneumatic filter cleaning.
Complete with control board for automatic start/stop, and vacuum protection.
The HVU is suitable for intensive use - up to 8-10 hours a day and can be connected to up to 12 outlets.
Art. No.
Description
[kW]
[Volt]
[m³/h]
at 0 Pa
[kPa]
Max
03-652
HVU-7 Complete unit
7,5
3x400V
680
33 kPa
03-653
HVU-11 Complete unit
11
3x400V
1.180
22 kPa
03-654
HVU-15 Complete unit
15
3x400V
1.180
35 kPa
Available with demand control upon request.
Note: All HVU-units are avaialbe with frequency inverter for increased performance.
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
71
Data for HVU
A
C
B
D
E
G
F
I
A
B
C
D
E
F
G
H
I
J
K
ø100/ø125mm Outlet
Removable top
Shield for side channel blower
Control panel with automatic
start/stop and filter cleaning
Pneumatic cleaning system
Safety valve
Filter cartridge - alu-coated
polyester tissue - antistatic
Shield for side channel blower
ø100/125 mm inlet
Collection bucket 25 litres
Frame with holes for forklift truck
H
J
K
Model
HVU-7
HVU-11 HVU-15
Power [kW]
Power consumption 100% load
Max. air flow
Max vacuum [kPa]
Filter surface area [m²]
Filtration level acc. to BIA-test [%]
7,5
15 A
680
33
12
99,9
74 dBA
4
25
11
22 A
1180
22
12
99,9
75 dBA
4
25
Sound pressure level acc. to ISO 3746-1979
Compressed air tank [litres]
Collection bucket [litres]
Cabinet + cyclone ø700 mm
Corrosion class (indoor)
Weight [kg]
øD
ød
HVU Dimensions
72
15
31 A
1180
35
12
99,9
76 dBA
4
25
Powder coatedPowder coatedPowder coated
II
261
102
102
II
307
127
127
II
328
127
127
HVU-Lite Dimensions
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Pressure drop for Geovent HVU
Pressure Drop for HVU 3, 5 and 7 kW
[Pa]
38.500
The values shown with dashed lines are
reached by using frequency inverter – 60 Hz
35.000
31.500
7,
5
28.000
kW
5,
24.500
8,
6
kW
5
5,
5
kW
21.000
3
6,
17.500
6,
3
kW
kW
4
kW
4,
6
4k
14.000
kW
W
10.500
kW
4,
6
7.000
kW
3.500
0
100
200
300
700
600
500
400
HVU 5
900
800
Air Flow [m³/h]
HVU 7
Pressure Drop for HVU 11 kW and 15 kW
[Pa]
25,2 kW
38.500
The values shown with dashed lines are
reached by using frequency inverter -60 Hz
20 kW
35.000
15 kW
31.500
28.000
17,3 kW
24.500
21.000
11 kW
17.500
12,6 kW
14.000
10.500
7.000
3.500
500
600
700
900
800
1000
1100
Air Flow [m³/h]
1200
1300
1400
1500
HVU 11
Pressure Drop for HVU 15P, 18P and
og 20P
[Pa]
38.500
The values shown with dashed lines are
reached by using frequency inverter -60 Hz
35.000
31.500
28.000
21,5 kW
18,5 kW
24.500
21.000
15 kW
12,5 kW
25,2 kW
14,5 kW
17.500
20 kW
14.000
17,3 kW
8,5 kW
10.500
9,8 kW
7.000
3.500
0
500
700
HVU-18P
900
1100
1300
1500
HVU-15P
1700
1900
2100
2300
2500
2700
2900
Air Flow[m³/h]
HVU-20P
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
73
HVU-IT - Integrated demand control and cleaning, 99,9% v/0,3µm
Geovent High Vacuum Unit HVU-IT is for example used for central vacuum
cleaning in hotels.
This version comes with a two step filter cyclone with a 7,5m² filter cartridgeand efficiency up to 99,9% and fully automatic pneumatic filter cleaning.
Complete with control board with built-in frequency inverter and PLC,
for automatic start/stop and demand control.
Blow-out to clean tube system and level indicator.
The side channel blower is equipped with vacuum protection and and
temperature protection.
Noise insulated cabinet for indoor placement. The HVU-IT is suitable for
intensive use and can be connected to up to 12 outlets.
Art. No. Description
[kW]
50Hz/60Hz
[m³/h]
v/ 0 Pa
[kPa]
Max
03-851
HVU-IT-5 Complete
unit 3x400V
5,5/6,3
590
22 kPa
03-852
HVU-IT-7 Complete
unit 3x400V
7,5/8,6
850
27 kPa
03-853
HVU-IT-11 Complete
unit 3x400V
11/12,6
1.475
19 kPa
03-854
HVU-IT-15 Complete
unit 3x400V
15/17,3
1.475
31 kPa
HVU Solo - stand alone module with side channel blower.
Geovent High Vacuum Unit for flexible placement.
The side channel blower is equipped with vacuum protection.
Art. No. Description
[kW]*
50Hz/60Hz
[m³/h]
v/ 0 Pa
[kPa]
Max
5,5/6,3
590
22 kPa
03-951
HVU Solo 5, 3x400V
03-952
HVU Solo 7, 3x400V
7,5/8,6
850
27 kPa
03-953
HVU Solo 11, 3x400V
11/12,6
1.475
19 kPa
03-954
HVU Solo 15, 3x400V
15/17,3
1.475
31 kPa
* 60Hz requires controlboard with frequency inverter.
HVU Solo is available in a version with increased performance - up to 2800m³/h.
Enquire at Geovent.
74
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
HVU Filter cyclone
Separate filter cyclone for HVU Solo. The Unit is equipped with a two-step
filtering through cyclone and filter cartridge. 99,9% efficient.
Shot valves for cleaning the filter cartridge.
Art. No. Description
03-955 Filter cyclone 5-7
03-956 Filter cyclone 11-15
03-956A Filter cyclone 11-15
Control not included.
Diameter
Connections
Filter
ø450
ø450
ø700
ø102
ø127
ø127
7,5m²
7,5m²
12m²
HVU Control boards
Available in 2 versions: STD and FRQ.
STD with automatic, pneumatic filter cleaning and automatic start/stop.
FRQ come with built-in frequency inverter (ABB ACS-355) for demand control,
automatic, pneumatic filter cleaning and automatic start/stop
Art. No. Description
19-133
HVU ST 5 STD
For HVU Solo 5 and 7, with direct start
19-131
HVU ST 11 STD
For HVU Solo 11 and 15, with soft start
19-120
HVU ST 5 FRQ
19-121
HVU ST 7 FRQ
19-122
HVU ST 11 FRQ
19-123
HVU ST 15 FRQ
HVU - Accessories for units
Art. No. Description
03-963
Sound insulation Solo cabinet
03-812
Police filter HVU 5
03-813
Police filter HVU 7
03-814
Police filter HVU 11-15
03-957
Pre-seperator HVU 5-7
03-958
Pre-seperator HVU 11-15
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
75
Accessories for High Vacuum Units
Art. No.
Description
03-259
Replacement cartridge ø315, HVU 12 m² - alu coated polyester
03-260
Replacement cartridge HVU-Lite 7,5m² alucoated polyester.
03-685
Energy satellite with ø80 mm High Vacuum outlets, ø150 mm
low vacuum outlet, 1 400V and 2 230V power outlet and
2 compressed air outlets. Customizable.
03-680
Energy arm 4 meters, two 2 tool hangers, 1 x ø50mm High
Vacuum outlet AD50 with flap, 2x230V and 1x400V 16 amp. power
outlet. On/Off button and 2 outlets for compressed air. Connection
on duct side is put together in a ø125mm flx hose. Equipped with
spring balancer. Customizable.
03-681
As above but 6 meters.
Hose reel for High Vacuum. When not in use the hose is reeled in to the reel.
The Hose Reel has an automatic damper which opens when the hose is pulled out and a micro
switch for start/stop of the High Vauum Unit. By default supplied with anti static hose and
pivotable mounting bracket.
Wall or ceiling mounting. Connection ø50mm.
Art. No.
Description
74-051
Hose Reel with 8m, ø38mm hose
74-052
Hose Reel with 7m, ø50mm hose
Art. No.
Description
74-480
ASA-HV50 Arm for High Vacuum 2 m. Ø50
74-481
ASA-HV50 Arm for High Vacuum 3 m. Ø50
74-482
ASA-HV50 Arm for High Vacuum 4 m. Ø50
74-483
Mini-HV50 Arm for High Vacuum 1 m. Ø50
74-484
Mini-HV50 Arm for High Vacuum 1,5 m. Ø50
74-485
Muffled HV hood with magnet
Art. No.
Description
74-058
Hose cart for High Vacuum hose. 2 connected hose reels, each with
6,5m ø38mm hose.
One outlet is connected to the outlet on the wall and the other to
a nozzle.
Total reach: approximately 13m.
Complete industrial vacuuming set ø32 for High Vacuum:
74-060
76
-Floor brush
-Telescopic tube and handle with 10,5m hose ø32
-Round brush
-Pointed mouth piece
-Furniture mouth piece
-Basket for accessories and hose holder
-Start/Stop button in handle.
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Accessories for High Vacuum, ø38
Art. No.
Description
74-502
Metal Mouth piece for industrial use, ø38
74-503
Floor Mouth Piece, plastic, ø38
74-504
Brush mouth piece, ø38
74-505
Slit mouth piece, ø38
Tube for mouth pieces. 1 set is one bend and a two-piece tube
74-500
Steel tube ø38, two-piece
74-501
Steel bend ø38
74-506
Hose connector ø38 for GeoFlex High ø38. Fits ø38 steel tube
Accessories for High Vacuum, ø50
Art. No.
Description
74-552
Floor Brush metal for industrial use, ø50
74-553
Brush mouth piece, ø50
Tube for Floor Brush. One set = 1 bend and a two-piece tube.
74-550
74-551
Steel tube ø50, two-piece
Steel bend- ø50
74-554
Hose connection ø50 for GeoFlex High ø50. Fits ø50 Steel tube
Accessories for High Vacuum
Art. No.
Description
74-077
Hose holder for wall.
74-078
Hose outlet w. hose holder and 45° angled AD50 valve.
For ø50mm tube.
74-079
Automatic hose outlet ø38 w. hose holder and bracket.
Damper included. Activates HVU Unit when hose is lifted off hose
holder. For ø50mm tube and 8 bar compressed air.
05-122
AD50 flap valve, glass reinforced nylon, without microswitch
74-081
AD50 flap valve, glass reinforced nylon, with microswitch
74-082
Outlet ø50mm w.AD50 flap valve. galvanized tube, wall bracket
and microswitch. For ø50mm tube.
74-100
Hose outlet with AD50 valve and wall bracket. Powder coated.
For ø63mm tube.
74-100A
As above but with microswitch.
74-101
Double outlet w. 2xAD50 Flap valve and wall bracket. Powder
coated. For ø100mm tube.
Additional charge for micro switch applies.
05-123
AKV universal adapter (male) for AD50 - Suits hose ø25-ø45
05-127
AKV adapter (male) for AD50 Suits hose ø50
05-128
AKV Hose reduction.
ø25 => ø32 => ø38 => ø45 => ø50
05-130
Bayonet Coupling ø32/ø32 For connecting 2 hoses
(With turning joint)
05-131
Bayonet Coupling ø38/ø38 for connecting 2 hoses
(With turning joint)
05-132
Y-coupling AKV/2 x ø32 mm hoses. For AD50 valve.
05-133
Y-coupling AKV/2 x ø38 mm hoses. For AD50 valve.
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
77
Flap valve
78
Couplings
Compressed air damper
Accessories for High Vacuum
Ducts and fittings for High Vacuum
Art. No.
Art. No.
Description
74-600
Metal Flap valve ø50-ø50
74-601
Metal Flap valve ø63-ø50
74-602
Metal Flap valve ø63-ø63
74-603
Metal Flap valve ø76-ø63
74-604
Metal Flap valve ø76-ø76
74-610
Metal Flap valve ø50-ø50 w/microswitch
74-611
Metal Flap valve ø63-ø50 w/microswitch
74-612
Metal Flap valve ø63-ø63 w/microswitch
74-613
Metal Flap valve ø76-ø63 w/microswitch
74-614
Metal Flap valve ø76-ø76 w/microswitch
Description
74-270
Galvanized duct ø50mm,
Length=3000mm
74-270L
Galvanized duct ø50mm,
Length=6000mm
74-271
Galvanized duct ø63mm,
Length=3000mm
74-271L
Galvanized duct ø63mm,
Length=6000mm
74-272
Galvanized duct ø76mm,
Length=3000mm
74-272L
Galvanized duct ø76mm,
Length=6000mm
74-620
Hose coupling ø50-ø38 for metal
flap valve ø50 and hose ø38
74-273
Galvanized duct ø102mm,
Length=3000mm
74-622
Hose coupling ø50-ø50 for metal
flap valve ø50 and hose ø50
74-273L
Galvanized duct ø102mm,
Length=6000mm
74-623
Hose coupling ø63-ø38 for metal
flap valve ø63 and hose ø38
74-274
Galvanized duct ø127mm,
Length=3000mm
74-624
Hose coupling ø63-ø63 for metal
flap valve ø63 and hose ø63
74-274L
Galvanized duct ø127mm,
Length=6000mm
74-625
Hose coupling ø76-ø50 for metal
flap valve ø76 and hose ø50
74-274A
Galvanized duct ø152mm,
Length=3000mm
74-640
Conn. piece ø50 for 2 hose couplings
74-274AL
74-641
Conn. piece ø63 for 2 hose couplings
Galvanized duct ø152mm,
Length=6000mm
74-642
Conn. piece ø76 for 2 hose couplings
74-660
Compressed air damper ø50
74-661
Compressed air damper ø63
74-662
Compressed air damperø76
74-663
Compressed air damper 102
74-664
Compressed air damper 127
74-665
Compressed air damper 152
74-670
Manual slide damper ø50
74-671
Manual slide damper ø63
74-672
Manual slide damper ø76
74-673
Manual slide damper ø102
74-674
Manual slide damper ø127
74-675
Manual slide damper ø152
74-680
Manual slide damper w/microswitch ø50
74-681
Manual slide damper w/microswitch ø63
74-682
Manual slide damper w/microswitch ø76
74-683
Manual slide damper w/microswitchø102
74-684
Manual slide damper w/microswitch ø127
74-685
Manual slide damper w/microswitch ø152
Ducts
74-275
Branch duct 50/50 mm 45°, galv.
Length=300mm
74-276
Branch duct 63/63 mm 45°, galv.
Length=300mm
74-277
Branch duct 63/50 mm 45°, galv.
Length=300mm
74-278
Branch duct 76/76 mm 45°, galv.
Length=300mm
74-279
Branch duct 76/63 mm 45°, galv.
Length=300mm
74-280
Branch duct 76/50 mm 45°, galv.
Length=300mm
74-284
Branch duct 102/102 mm 45°, galv.
Length=300mm
74-283
Branch duct 102/76 mm 45°, galv.
Length=300mm
74-282
Branch duct 102/63 mm 45°, galv.
Length=300mm
74-281
Branch duct 102/50 mm 45°, galv.
Length=300mm
74-450
Branch duct 127/127 mm 45°, galv.
Length=300mm
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Branch tube
Bends
Reductions
Connectors
Ducts and fittings for High Vacuum
Ducts and fittings for High Vacuum
Art. No.
Art. No.
Description
Description
74-451
Branch duct 127/102 mm 45°, galv.
Length=300mm
74-290
Bend ø76x45°, Centre radius=160mm
74-452
Branch duct 127/76 mm 45°, galv.
Length=300mm
74-290A
Bend ø102x45°,Centre radius=160mm
74-453
Branch duct 127/63 mm 45°, galv.
Length=300mm
74-290C
Bend ø127x45°, Centre radius=160mm
74-454
Branch duct 152/152 mm 45°, galv.
Length=300mm
74-290D
Bend ø152x45°, Centre radius=
160mm
74-455
Branch duct 152/127 mm 45°, galv.
Length=300mm
74-456
74-291
Reduction 63-50 Branch duct 152/102 mm 45°, galv.
Length=300mm
74-292
Reduction 76-63
74-293
Reduction 76-50 74-457
Branch duct 152/76 mm 45°, galv.
Length=300mm
74-294A
Reduction 102-76 74-458
Branch duct 152/63 mm 45°, galv.
Length=300mm
74-294
Reduction 102-63 74-460
Reduction 127-102 74-461
Reduction 127-76
74-264
Y duct ø50 for High Vacuum
74-462
Reduction 152-127 74-265
Y duct ø63 for High Vacuum
74-463
Reduction 152-102
74-266
Y duct ø76 for High Vacuum
74-267
Y duct ø102 for High Vacuum
74-295
74-268
Y duct ø127 for High Vacuum
Duct connection ø50mm with
antistatic seal
74-269
Y duct ø152 for High Vacuum
74-296
Duct connection ø63mm with
antistatic seal
74-297
Duct connection ø76mm with
antistatic seal
74-298
Duct connection ø102mm with
antistatic seal
74-299
Duct connection ø127mm with
antistatic seal
74-299A
Duct connection ø152mm with
antistatic seal
74-285
Bend ø50x90°, Centre radius=160mm
74-286
Bend ø63x90°, Centre radius=160mm
74-287
Bend ø76x90°, Centre radius=160mm
74-287A
Bend ø102x90°, Centre radius=160mm
74-287C
Bend ø127x90°, Centre radius=160mm
74-287D
Bend ø152x90°, Centre radius=160mm
74-288
Bend ø50x45°, Centre radius=160mm
74-289
Bend ø63x45°, Centre radius=160mm
74-310
74-311
74-312
74-313
74-314
End cap ø50
End cap ø63
End cap ø76
End cap ø102
End cap ø127
74-315
Suspension bracket for
Duct connection
All ducts and fittings are galvanized inside and outside.
Ducts and fittings are available in stainless steel - enquire.
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
79
High Vacuum application
Energy arm for HVU
A
B
E
D
C
F
H
J
I
Dimension the duct system so you have an air velocity of
at least 23 m/s to avoid dust accumulation.
Air velocity at the outlet must be minimum 8 m/s and 2
metres over the ridge of the roof.
Description
A.
Outlet - clean air
B.
High Vauum Unit
C.
Cyclone with collection bucket
D.
Control board with automatic start/stop
E.
ø100mm/ø125mm High Vacuum ducts
F.
Extension arms 4 or 6 m.
Energy console with 2 High Vacuum outlets.
1 400V and 1 230V power outlet
3 compressed air outlet with start/stop for
High Vacuum unit. Customisable on request.
2 ø50mm High Vacuum outlets w/microswitch for start/stop of
High Vacuum unit.
Tubes below floor
G.
H.
I.
J.
80
Energy satellite with ø80mm High Vacuum outlets, ø150mm
Low Vacuum outlet, 1 400V and 2 230V power outlet and 2
compressed air outlet.
G
By default the energy arm for HVU comes with:
4m arm (03 680) or 6m arm (03 681),
Retractable balancer and box with 2 tool hangers,
1xø50mm HVU outlet (AD50 valve with flap),
2 230V outlets,
1 3x400V 16A outlet,
1 ON/OFF button and 2 compressed air outlets.
All connections and hoses are consealed in a ø125mm
flex hose.
Application
•
•
•
Grinding dust extraction from
rotary and vibration sanders.
Extraction of metal shavings from milling,
turning and sawing processes.
Ordinary work station cleaning.
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
HVU details
Hose reel for HVU
Custom electronics to control the HVU.
The core of the High Vacuum System:
A heavy duty side channel blower.
Pressurised slide damper.
81
ATEX
Explosion proof products
All ATEX-products from Geovent are manufactured in
compliance with the directive 94/9/EC.
It is the responsibility of the individual employer to obtain
zone-classifications in the company concerned, and
often this is carried out in cooperation with local
authorities or qualified consultants.
For further information regarding ATEX, please refer to
local instructions for work in ATEX and explosive
atmospheres.
European companies are obliged to assess whether there is
a risk of explosion in connection with their
production as a result of ignition of an atmosphere
consisting of air mixed with flammable gases, vapours,
fluids, mist/aerosols or flammable dust mists.
If so, the risk must be assessed as the foundation of a
classification of the area(s) in danger of explosion.
In addition to this, the company must take precautions in
order to avoid explosions and to draw up documentation
The central principle is to divide the company into zones on
basis of the risk of explosion and its consequences.
In this connection, it is necessary both to consider the type
and the volume of leak, ventilation, safety systems and the
potential ignition sources, as for instance electrostatic
charge, electrical installations and mechanically generated
sparks. The assessment is to apply to existing equipment as
well as to new acquisitions of machinery and equipment.
A complete set of documentation is supplied with a
Geovent Atex product.
Zone
Equipment
Geovent Equipment
Category 1
G (gas)
--
Category 1 or 2
G (gas)
MSX/MEX fan
Area, where during normal operation an explosive atmosphere, consistingof a mixture of air with flammable gas, vapour or mist probably does
not occur. However, if it occurs, it will only be for a short period of time.
Area, where constantly, frequently or for a longer period of time there
may be an explosive atmosphere, consisting of a cloud of flammable
dust and air.
Category 1, 2 or 3
G (gas)
MSX/MEX fan
Category 1
D (dust)
GFX filter
21
Area, where occasionally during normal operation an explosive
atmosphere consisting of a cloud of flammable dust and air may occur.
Category 1 or 2
D (dust)
GFX filter
MSX/MEX fan
22
Area, where during normal operation an explosive atmosphere, consisting of a cloud of flammable dust and air may most probably not occur,
and should it occur anyhow, it will only be for a short period of time.
Category 1, 2 or 3
D (dust)
GFX filter
MSX/MEX fan
0
Area, where constantly, frequently or for a longer period of time there is
an explosive atmosphere, consisting of a mixture of air and flammable
gas, vapours or mist.
1
Area, where an explosive mixture of air and fl ammable gas, vapour or
mist may occasionally occur, during normal operation.
2
20
82
Description
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
LSX / MSX – ATEX fan with forward curved scirocco impeller
Zone 1, 2 and 22
Art. No.
Description
[kW]
[A]
Max [m³/h]
Max[Pa]
37-010
LSX-146-3
0,25
0,81
700
160
37-020
MSX-146-3
0,55
0,93
900
620
37-030
LSX-180-3
0,37
0,93
1.175
230
37-040
MSX-180-3
0,55
1,30
1.670
950
37-050
LSX-200-3
0,75
2,20
1.750
320
37-060
MSX-200-3
1,10
2,60
2.100
1.450
37-070
LSX-225-3
1,35
3,10
2.500
450
37-080
MSX-225-3
1,85
3,82
2.450
1.500
37-090
LSX-250-3
2,00
5,10
3.150
470
37-100
MSX-250-3
3,30
6,20
3.160
1.800
Please state required zone when ordering.
LEX / MEX – ATEX fan backward curved blades
Zone 1, 2, 21 and 22
Art. No.
Description
[kW]
[A]
Max [m³/h]
Max[Pa]
37-510
LEX-250-3
0,25
0,80
700
230
37-520
MEX-250-3
0,37
1,00
1.650
1.200
37-530
LEX-315-3
0,25
0,80
1.450
360
37-540
MEX-315-3
0,75
1,75
2.850
1.330
37-550
LEX-355-3
0,25
0,80
2.250
425
37-560
MEX-355-3
1,50
3,30
4.350
1.550
37-570
LEX-400-3
0,37
1,05
2.500
500
37-580
MEX-400-3
4,00
8,80
6.300
2.150
37-590
LEX-450-3
0,75
1,86
4.700
700
37-591
MEX-450-3
5,50
11,10
9.000
2.600
37-592
MEX-500-3
7,50
14,70
11.400
3.350
37-593
LEX-630-3
4,00
8,30
14.000
1.600
Please state required zone when ordering.
Pressure drop curves for ATEX fan LSX/MSX 146 to 250
Fan MSX 146 - 250
550
1750
500
1600
450
1450
400
250
225
1300
350
200
1050
250
300
250
225
200
150
180
100
50
Pressure drop [Pa]
Pressure drop [Pa]
LSX 146 - 250
Fan LSFG
200
900
180
750
600
450
300
146
150
300 600 900 1200 1500 1800 2100 2400 2700 3000 3300
Airflow [m³/h]
146
500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500
Airflow [m³/h]
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
83
Pressure drop curves for ATEX fan LEX/MEX 250 to 355
Dashed line = Requires specially adjustable motor.
Contact Geovent for further information.
[Pa]
Fan LEX-MEX-355
n=3540
(2p - 62Hz)
2400
82%
89
n=3277
(2p - 57Hz)
(
dB
2100
Efficiency
Sound level outlet
- no duct
75%
A)
78%
88
1800
(
dB
1500
68%
85
1350
A)
)
dB
79
(A
)
Revs. per minute
and frequency
Example: A pressure controlled fan with frequency inverter connected to
4 extraction arms. If all 4 arms are in use 4.200 m³/h at1.200 Pa.
If 2 arms are shut off simultaneously the air flow will be regulated to
2.000 m³/h thus halving the power consumption.
Fan LEX/MEX-315
(
dB
A)
(
dB
A)
68%
(
dB
A)
n=2507
(2p - 44Hz)
51%
dB
82
n=2240
(2p - 39Hz)
(A
)
(A
750
46%
)
1200 1500 1800 2100 2400 2700 3000 3300
78%
88
n=2860
(2p - 50Hz)
3,0kW
600
450
300
n=1460
(4p - 50Hz)
(2p - 25Hz)
2,2kW
1,5kW
1,1kW
)
0,37kW
0,25kW
Air Flow [m³/h]
82%
n=3277
(2p - 57Hz)
dB
79
900
75%
(A
dB
600
n=3540
(2p - 62Hz)
69
300
48%
1,1kW
0,75kW
0,55kW
0,12kW
1000 1200 1400 1600 1800 2000 2200
85
)
A)
A)
800
89
)
(A
(A
)
B(
600
Fan LEX/MEX-355
dB
dB
79
64
d
130
84
900
59%
(A
dB
72
dB
(
0,09kW
400
Air Flow [m³/h]
1050
A)
B(
260
n=1460
(4p - 50Hz)
(2p - 25Hz)
200
1200
d
77
n=2010
(2p - 35Hz)
520
390
125
1350
71%
73
650
n=2280
(2p - 40Hz)
0,37kW
0,25kW
0,18kW
n=1460
(4p - 50Hz)
(2p - 25Hz)
1500
80%
n=2560
(2p - 45Hz)
(A
)
1800
81
n=2860
(2p - 50Hz)
48%
0,55kW
250
2100
84%
1170
780
57
dB
375
2400
1430
64%
65
B(
A)
[Pa]
74%
n=3200
(2p - 56Hz)
1560
910
n=2560
(2p - 45Hz)
500
Air flow [m³/h]
[Pa]
n=2860
(2p - 50Hz)
A)
625
76%
B(
750
0,25kW
1040
1000
76
(A
dB
1,1kW
1000 1500 2000 2500 3000 3500 4000 4500 5000 5500
1300
83%
n=3480
(2p - 61Hz)
1125
875
0,75kW
1690
1250
1,5kW
150
500
1375
)
(A
2,2kW
69
n=1460
(4p - 50Hz)
(2p - 25Hz)
69%
dB
79
3,0kW
600
300
Power
Consumption
46%
)
750
450
n=3995
(2p - 70Hz)
(A
n=2240
(2p - 39Hz)
900
51%
dB
82
1050
Pressure drop at a
given air flow
(
dB
n=2507
(2p - 44Hz)
1200
1625
Fan LEX-MEX-250
1500
A)
n=2860
(2p - 50Hz)
[Pa]
0,75kW
150
0,25kW
500
1000 1500 2000 2500 3000 3500 4000 4500 5000 5500
Airflow [m³/h]
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Pressure drop curves for ATEX fan LEX/MEX 400 to 630
Dashed line = Requires specially adjustable motor.
Contact Geovent for further information.
Fan LEX/MEX-400
[Pa]
2800
3600
85%
2400
2000
1200
900
4,0kW
)
(A
50%
5,5kW
n=2120
(2p - 36Hz)
n=1585
(2p - 27Hz)
300
1200 2400 3600 4800 6000 7200 8400 9600 10800 12000 13200
Air Flow [m³/h]
1500 2250 3000 3750 4500 5250 6000 6750 7500 8250
86%
dB
(A
n=1830rpm
(4p - 63 Hz)
)
62%
)
15kW
(A
)
Air Flow [m³/h]
250
dB
1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000
500
(A
)
2,2kW
0,75kW
750
84
4,0kW
52%
21 kW
dB
1000
n=1440rpm
(4p - 50 Hz)
86
7,5kW
)
1250
n=1584rpm
(4p - 55 Hz)
)
(A
1500
dB
1750
49%
5,5kW
(A
dB
250
74%
89
)
(A
dB
n=1395
(4p - 50Hz)
n=2030rpm
(4p - 70 Hz)
92
)
62%
73
500
2000
)
(A
)
(A
dB
n=2120
(2p - 36Hz)
1000
750
2250
74%
83
1250
2500
(A
dB
1500
81%
87
1750
82%
dB
2750
(A
dB
n=2552
(2p - 44Hz)
n=2300rpm
(2p - 41 Hz)
3000
92
n=2900
(2p - 50Hz)
( A)
3250
dB
3500
81%
89
2000
79% n=2600rpm
86%
(2p - 46 Hz)
3750
2500
2250
Fan LEX / MEX-630
4000
94
2750
[Pa]
Fan LEX/MEX-450
74%
n=3306
(2p - 57Hz)
2,2kW
97
3000
51%
7,5kW
5,5kW
4,0kW
1,1kW
Air Flow [m³/h]
3250
68%
600
1,1kW
[Pa]
76%
A)
1500
82%
dB
1800
0,37kW
750
n=2430
(2p - 42Hz)
2100
2,2kW
200
)
(A
dB
87
75%
68%
70
dB
(A)
87%
(
dB
77
n=1375rpm
(4p - 50Hz)
n=2690
(2p - 46Hz)
)
(A
dB
73
600
400
2400
)
(A
dB
79
800
83%
2700
(A)
dB
84
n=2150rpm
(2p - 37Hz)
n=2900 77%
(2p - 50Hz)
81
)
(A
dB
86
n=2675rpm
(2p - 46Hz)
1200
1000
3000
80%
1800
1400
3300
(A)
dB
90
n=2915rpm
(2p - 50Hz)
2200
1600
3900
82%
2600
FanFan
LEX/MEX-500
MEX-500
[Pa]
75%
n=3538rpm
(2p - 61Hz)
11kW
7,5kW
5,5kW
4,0kW
2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000 24000 26000
Airflow [m³/h]
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
85
ASX extraction arm with external articulated arm and gas spring.
Extraction arm for use in explosive atmosphere (ATEX)
Extraction arm grounded twice (Resistance R<108Ω) ensures that the arm will
not function as ignition.
This allows these arms to be used in areas with both dust and gas classified as
explosive(ATEX).
The ASX arms are based on the construction of our ASA arm.
86
Art. No.
Description
ASX-01
ASX arm 2,0m ø80mm, complete
ASX-05
ASX arm 2,0m ø80mm complete w/damper
ASX-11
ASX arm 3,0m ø80mm, complete
ASX-15
ASX arm 3,0m ø80mm, complete w/damper
ASX-21
ASX arm 4,0m ø80mm, complete
ASX-25
ASX arm 4,0m ø80mm complete w/damper
ASX-02
ASX arm 2,0m ø100mm, complete
ASX-06
ASX arm 2,0m ø100mm complete w/damper
ASX-12
ASX arm 3,0m ø100mm, complete
ASX-16
ASX arm 3,0m ø100mm complete w/damper
ASX-22
ASX arm 4,0m ø100mm complete
ASX-26
ASX arm 4,0m ø100mm complete w/damper
ASX-03
ASX arm 2,0m ø125mm, complete
ASX-07
ASX arm 2,0m ø125mm, complete w/damper
ASX-13
ASX arm 3,0 m ø125mm, complete
ASX-17
ASX arm 3,0 m ø125mm, complete w/damper
ASX-23
ASX arm 4,0 m ø125mm, complete
ASX-27
ASX arm 4,0 m ø125mm, complete w/damper
ASX-04
ASX arm 2,0m ø160mm, complete
ASX-08
ASX arm 2,0m ø160mm, complete w/damper
ASX-14
ASX arm 3,0m ø160mm, complete
ASX-18
ASX arm 3,0m ø160mm, complete w/damper
ASX-24
ASX arm 4,0m ø160mm, complete
ASX-28
ASX arm 4,0m ø160mm, complete w/damper
ASX-31
ASX arm 2,0m, ø200mm, complete
ASX-32
ASX arm 2,0m ø200mm, complete w/damper
ASX-33
ASX arm 3,0m ø200mm, complete
ASX-34
ASX arm 3,0m ø200mm, complete w/damper
ASX-35
ASX arm 4,0m ø200mm, complete
ASX-36
ASX arm 4,0m ø200mm, complete w/damper
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
GeoFilter GFX – ATEX filter for zone 20, 21 and 22
Art. No.
16-400
16-401
16-402
16-403
Description
Filter area Max m³/h
GeoFilter GFX-3-1
GeoFilter GFX-6-2
GeoFilter GFX-9-3
GeoFilter GFX-12-4
30 m²
60 m²
90 m²
120 m²
1800
3600
5400
7200
Geovent GFX filter is used for category 1, 2, and 3 D (dust), making it suitable for dust
applications such as aluminium dust, magnesium, flour and more in
zone 20, 21 or 22.
The filter is 99,9 % efficient at 0,3 µm, and is cleaned automatically by using
shot valves with compressed air.
The filter is galvanised and is supplied with a 25 L collection bucket.
A GFX filter is supplied complete with ATEX control, explosion membrane, spark proof
filter cartridges, ATEX shot valves and full ATEX documentation.
Compressed air
Air consumption
Power supply
Temperature
Typical
pressure drop
Sound level
Protection
class
3,5-5 bar
clean and dry air
3,0 liter/min per
valve
24VDC eller 230 VAC
-12°C - +65°C
1000-1500 Pa
<68 dB(A)
Class C
HVUX - High Vacuum units for ATEX applications
GEOVENT high vacuum units (HVU and HVU Lite), are available in ATEX versions for
use with dust applications. HVUX and HVUX Lite are designed for a dust filled
atmosphere classified as zone 21 or 22.
HVUX or HVUX Lite can also be used in areas classified as explosive (zone 21 and 22).
HVUX and HVUX Lite are tailored to suit your needs.
They are available with for example ATEX side channel blower, explosion membrane.
eksplosionsmembran, police filter (extra protection in case of leak in the primary
filter) and customised control with several alarm options.
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
87
W elding
S V E J SbEoKoAths
BINER
GEOVENT supply welding booths, welding
walls/shielding and noise damping for work stations.
This can be done as single walls made of diffferent
types of sheets, with or without welding curtain or
more advanced solutions with roof and center column
for extraction, power and ventilation.
The welding booths are available as sandwich built
structures with a smooth or perforated panels.
For noise damping the panels are insulated with
mineral wool.
88
5x5m booths with 4 work stations.
Each station is equipped with seperate outlet for
extraction.
Contact Geovent for information on prices and options.
Shown on these pages are examples of welding booths
from GEOVENT.
89
Welding Booths - Description
Art. No.
Description
Panel Outside/Inside
Examples
01-303
Geo-Dan 30 Perf/Perf, 50mm, per m²
01-304
Geo-Dan 60 Perf/Perf, 100mm, per m²
01-305
Geo-Dan 30 PO/PO, 50mm, per m²
01-306
Geo-Dan 60 PO/PO, 100mm, per m²
01-307
Geo-Dan 30 PO/Perf, 50mm, per m²
01-308
Geo-D an 60 PO/Perf, 100mm, per m²
U-rail for panel assembly
01-309
U-rail, PO 50mm, per meter
01-310
U-rail, PO 100mm, per meter
Use one U-rail all the way around each wall(standard sizes)
PO=Powder coated - Perf.=perforated
Panels for welding booths and noise damping.
Geo-Dan sandwich built elements with 0,6 mm galvanised and powder coated steel
sheet metal on both sides. The panels have a mineral wool core.
Thicknesses: 50 and100mm with smooth powder coated (PO) or perforated,
powder coated sheet metal. (Perf).
Geo-Dan are assembled with snap lock and sealing.
The panels are approved for use as fire wall according to Danish standards.
Silver (RAL 9006) by default but available in other RAL colours.
Thickness
Heat loss
Width
Weight
Geo-Dan 30
50mm
0,67 W/m²
557mm
19,0 kg/m²
Geo-Dan 60
100mm
0,34 W/m²
557mm
26,1 kg/m²
Noise reduction dB ± 3
Panel outside/inside
Hz
63
125
250
500
1k
2k
4k
Geo-Dan 30 PO/PO
dB
21
25
29
32
36
38
42
Geo-Dan 60 PO/PO
dB
28
30
32
36
39
44
49
Geo-Dan 30 PO/Perf
dB
17
20
20
24
25
27
32
Geo-Dan 60 PO/Perf
dB
23
22
22
29
29
32
39
Accessories for welding booths
•
•
•
•
•
Extra insulation to avoid thermal bridges.
U-rails for combining several panels.
V-rails inside and outside for extra finish.
Windows and doors.
Curtain and rails and more.
Please enquire for more information on drawings, prices and special requests.
90
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Welding curtain (translucent)
By default the curtain is green. Other colours on request.
Standard sizes shown, special sizes on request.
Soft but tough quality.
Art. No.
Description
01-320
Welding curtain 180 x 130 cm
01-322
Welding curtain 180 x 180 cm
01-328
Velcro connection 180 cm
01-325
Other sizes – per m² - Min. 10m² per curtain +10% for folds
Brackets and suspension
Art. No.
Description
01-340
C-rail 42x50 mm Lengths of 7 m.
07-828
Connector w. grub screws for 2 lengths of C-profile 42x50 mm
01-342
Arch 600 mm 42x50 mm profile
01-343
Curtain roller with hook for C-profile 42x50 mm.
01-345
Rail stop
01-347
Wall bracket for 42x50 C-profile
01-350
Ceiling bracket for 25x25 C-profile
01-344
Ceiling bracket for 42x50 C-profile
07-817
Ceiling bracket w. adjustment tread.
Bolt M12x60mm. Use with 01-351
01-351
Wall bracket for wall mounting
01-335
01-335A
01-354
01-354A
Mounting on frame
S-hook, galvanised. 4,2x45mm
Curtain hook (drop). ø42mm, l=72mm
Welding curtain stand 200 x 180 cm., Curtain included
Welding curtain stand 200 x 360 cm., Curtain included
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
91
Welding table - down draft
Art. No.
02-001
02-002
H
02-003
02-005
B
D
02-006
Description
Welding table – 600x600x800 mm (WxDxH)
Air flow needed: ca. 1.500m³/h – connecting piece: ø160 mm
Welding table – 900x600x800 mm (WxDxH)
Air flow needed: ca. 2.000m³/h – connecting piece: ø200 mm
Welding table – 1.200x600x800 mm (WxDxH)
Air flow needed: ca. 2.500m³/h – connecting piece: ø250 mm
Welding table – 1.800x1.000x800 mm (WxDxH)
Air flow needed: ca. 6.000m³/h – connecting piece: ø400 mm
Welding table – 2.500x800x800 mm (WxDxH)
Air flow needed: ca. 5.000m³/h – connecting piece: 2xø315 mm
(in both ends of the table)
Rear Edge Extraction
Art. No.
Description
02-030
Rear edge extraction - 900x185x600mm (WxDxH) Air need: ca.
1.000 - 1.500 m³/h - connecting piece: ø200 mm w. collection
bucket
02-037
Corner console for Rear edge extraction
Smoking cabin
Smoking cabin specially designed for use off shore and on board ships.
Withstands vibrations.
With EC-fans and push/pull-system. The air is filtered 99,9% through EU5, active carbon and
Hepa-filters, and is the recirculated. Light and fan activated using sensor.
Capacity: 350m³/h, 1x230V 50Hz, Consupmtion 175W/1,3A, 45dB(A),
HxWxD: 2000x1200x1000mm
Art. No.
02-100
Description
Smoking cabin. Complete, partially assembled.
Accesories
15-499
Pre filter for smoking cabin
15-500
Hepa filter 610-305
15-501
Carbon filter H13 1500
Spray booth
Spray booth for smaller item. With light, Andreae-filter, wheels and drip tray. Galvanised.
Recommended air flow: 2.000m³/h, duct ø250mm. 230V.
H: 2035mm W: 1000mm D:1000mm
Art. No.
Description
01-800
Spray booth
Andreafilter for spray booth
92
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
W elding , grinding , paint and m o re
Welding/grinding table with
rear extraction panels
Spray booth for
paint shops
Energy arm for
High Vacuum
Preservation tub for preserving
metal parts
- with local extraction
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
93
G R T U R o o f t o p unit
GRTU Roof top mounted ventilation units with heat recovery
are designed for comfort ventilation in repair shops, warehouses
and production facilities.
GRTU uses energy efficient EC fans with B-wheels.
The fans comply with the latest requirements - IE3, 2015.
The fans are 100% steplessly adjustable so you can achieve the
desired air flow for the job at hand.
GRTU is a flexible and economically attractive solution as the
roof mounting eliminates the need for extensive duct work.
94
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Flexibility without the compromise.
The Geovent GRTU Roof Top Unit
ensures steady and stable operation as it
is designed using only selected quality
components.
The rotary heat exchanger has a
very large area for optimum performance.
The entire construction is galvanised
and sealed in all joints.
The GRTU is modular and with rails
making for easy inspection and service.
The mounting frame makes it easy to install the
unit on both a flat and a sloped roof.
The GRTU 3800 can also be mounted indoors if required.
(Must be specified when ordering.)
Extraction and air supply is in the bottom of the unit.
Choose between ducting or a diffusor solution
Normally we recommend the duct solution as it gives a better mixing of the air.
The GRTU units are fitted with high quality
controls and operated by hand terminal.
Top view
Side view
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
95
GRTU Roof Top Unit with heat recovery
Art. No.
Description
02-602
GRTU 3800 standard edition includes rotor. One speed Panel filter
F5 in extraction and supply. Digital control with operating panel.
Up to 3800 m3/h
02-602A
GRTU 3800 +
As above but with, 3000rpm alu wheel.
02-703
Shut-off damper without motor. Used in intake and outlet and as
recirculation damper
02-710
Motor for damper LMC 24 A
02-711
Heating coil 10 KW water 70/40
Use where only ventilation is needed.
02-713
Heating coil 25 KW vand 70/40
Use where heating and recirculation is needed.
Both heating coils measures 600 x 600 mm
and is suitable for duct mounting.
96
02-712
Two-way valve R210 + motor TR24 SR
Suitable for 10 KW heating coil
02-714
Two-way valve R212 + motor TR24SR
Suitable for 25 KW heating coil
02-705
Room sensor ( use when heating)
02-704
Temperature sensor / Freeze protection Use with heating coil. 10 and 25 kW
02-715
Diffusor set:
Reduction piece, Flex hose ø 500 with clamps
and diffusor mounted on 800 x 800 rectangular duct
02-761
Exetension duct 800 x 800 x 500
02-762
Exetension duct 800 x 800 x 1000
09-017
Flex hose ø 500, per meter
02-716
Panel filter EU 5
02-717
Cartridge filter F7
Set: 2 filters and adaptors for each airflow.
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
GeoFlex Exhaust (-40°C to +150°C )
Use: Extraction of exhaust
fumes and welding smoke.
Briefly 170° C - TPE w/nylon coil
Art. No.
Description
Weight
Bend
09-075A
GeoFlex Exhaust ø76 – 5 m pcs.
3,45 kg
105 mm
09-075B
GeoFlex Exhaust ø76 – 7,5 m pcs.
5,18 kg
105 mm
09-075C
GeoFlex Exhaust ø76 – 10 m pcs.
6,9 kg
105 mm
09-075D
GeoFlex Exhaust ø76 – 15 m pcs.
10,4 kg
105 mm
09-076A
GeoFlex Exhaust ø102 – 5 m pcs.
4,4 kg
190 mm
09-076B
GeoFlex Exhaust ø102 – 7,5 m pcs.
6,6 kg
190 mm
09-076C
GeoFlex Exhaust ø102 – 10 m pcs.
8,7 kg
190 mm
09-076D
GeoFlex Exhaust ø102 – 15 m pcs.
13,1 kg
190 mm
09-077A
GeoFlex Exhaust ø127 – 5 m pcs.
6,0 kg
250 mm
09-077B
GeoFlex Exhaust ø127 – 7,5 m pcs.
9,0 kg
250 mm
09-077C
GeoFlex Exhaust ø127 – 10 m pcs.
12,0 kg
250 mm
09-077D
GeoFlex Exhaust ø127 – 15 m pcs.
18,0 kg
250 mm
09-078A
GeoFlex Exhaust ø152 – 5 m pcs.
7,2 kg
300 mm
09-078B
GeoFlex Exhaust ø152 – 7,5 m pcs.
10,8 kg
300 mm
09-078C
GeoFlex Exhaust ø152 – 10 m pcs.
14,4 kg
300 mm
09-078D
GeoFlex Exhaust ø152 – 15 m pcs.
21,6 kg
300 mm
09-079A
GeoFlex Exhaust ø200 – 5 m pcs.
8,4 kg
350 mm
09-079B
GeoFlex Exhaust ø200 – 7,5 m pcs.
12,6 kg
350 mm
09-079C
GeoFlex Exhaust ø200 – 10 m pcs.
16,8 kg
350 mm
09-079D
GeoFlex Exhaust ø200 – 15 m pcs.
25,2 kg
350 mm
GeoFlex Silicone coated Kevlar HT (-60°C to +300°C)
Art. No.
Use:
Extraction of hot vapours,
exhaust or dust
Silikone coated Kevlar w/stainless coil
Description
Weight
Bend
09-190
GeoFlex Kevlar ø83, per meter
0,8 kg/m
48 mm
09-191
GeoFlex Kevlar ø102, per meter
0,9 kg/m
60 mm
09-192
GeoFlex Kevlar ø127, per meter
1,0 kg/m
75 mm
09-193
GeoFlex Kevlar ø152, per meter
1,25 kg/m
90 mm
09-194
GeoFlex Kevlar ø160, per meter
1,28 kg/m
96 mm
09-195
GeoFlex Kevlar ø203, per meter
1,65 kg/m
140 mm
09-196
GeoFlex Kevlar ø254, per meter
2,0 kg/m
175 mm
09-197
GeoFlex Kevlar ø305, per meter
2,25 kg/m
210 mm
(Kevlar-reinforced 300° C hose- lengths of 1 to10 m)
GeoFlex Exhaust HT-450 (-60°C to +450°C)
Art. No.
09-130
Use:
Extraction of hot vapours,
exhaust or dust
Silikone coated fibre glass w/stainless coil
Description
Weight
Bend
GeoFlex Exhaust HT-450 ø102, per m.
1,3 kg/m
60 mm
09-131
GeoFlex Exhaust HT-450 ø127, per m.
1,4 kg/m
75 mm
09-132
GeoFlex Exhaust HT-450 ø152, per m.
1,8 kg/m
90 mm
09-133
GeoFlex Exhaust HT-450 ø160, per m.
1,8 kg/m
96 mm
09-134
GeoFlex Exhaust HT-450 ø203, per m.
2,3 kg/m
120 mm
GeoFlex Exhaust HT-650 (-60°C to +650°C)
Art. No.
09-159
Use:
Extraction of hot vapours,
exhaust or dust
Special High temperatur-weave/stainless steel coil
Description
Weight
Bend
GeoFlex Exhaust HT-650 ø102, per m.
1,8 kg/m
60 mm
09-161
GeoFlex Exhaust HT-650 ø127, per m.
2,1 kg/m
75 mm
09-163
GeoFlex Exhaust HT-650 ø152, per m.
2,2 kg/m
90 mm
09-164
GeoFlex Exhaust HT-650 ø160, per m.
2,4 kg/m
96 mm
09-165
GeoFlex Exhaust HT-650 ø203, per m.
3,0 kg/m
120 mm
GeoFlex Exhaust HT-450 and 650 available in lenghts of 1 to10 m
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
97
GeoFlex Exhaust HT-1100 (-60°C to +1100°C)
Art. No.
3 ply Special High temp.-weave/stainless steel coil
Description
Weight
Bend
GeoFlex Exhaust HT-1100 ø102, Per m.
1,2 kg/m
60 mm
09-141
GeoFlex Exhaust HT-1100 ø127, Per m.
1,5 kg/m
75 mm
09-142
GeoFlex Exhaust HT-1100 ø152, Per m.
1,7kg/m
90 mm
09-140
09-143
GeoFlex Exhaust HT-1100 ø160, Per m.
1,7 kg/m
96 mm
09-144
GeoFlex Exhaust HT-1100 ø203, Per m.
2,2 kg/m
120 mm
available in lenghts of 1 to 10 m
Use:
Extraction of for ex. exhaust from
locomotives, tanks and more with
very high temperatures.
GeoFlex Standard (-40°C to +140°C)
Art. No.
PVC / ALU
Description
Weight
Bend
09-012
GeoFlex Standard ø50, 10 meters Pcs.
0,146 kg/m
28 mm
09-002
GeoFlex Standard ø82, 10 meters Pcs.
0,162 kg/m
46 mm
09-003
GeoFlex Standard ø102, 10 meters Pcs.
0,171 kg/m
57 mm
09-005
GeoFlex Standard ø127, 10 meters Pcs.
0,212 kg/m
71 mm
09-001
GeoFlex Standard ø152, 10 meters Pcs.
0,326 kg/m
85 mm
09-004
GeoFlex Standard ø160, 10 meters Pcs.
0,357 kg/m
90 mm
09-000
GeoFlex Standard ø203, 10 meters Pcs.
0,461 kg/m
114 mm
09-019
GeoFlex Standard ø254, 10 meters Pcs.
0,618 kg/m
142 mm
Use:
Extraction of air, welding smoke
and fumes.
GeoFlex P2A 1000 (-30°C to +80°C)
Art. No.
PVC / Polyester weave, steel coil
Weight
Bend
GeoFlex P2A 1000 ø80
0,24 kg/m
56 mm
09-307
GeoFlex P2A 1000 ø100
0,30 kg/m
70 mm
09-310
GeoFlex P2A 1000 ø125
0,38 kg/m
88 mm
09-312
GeoFlex P2A 1000 ø150
0,45 kg/m
105 mm
09-313
GeoFlex P2A 1000 ø160
0,54 kg/m
114 mm
09-306
Description
09-314
GeoFlex P2A 1000 ø200
0,72 kg/m
140 mm
09-315
GeoFlex P2A 1000 ø250
0,90 kg/m
175 mm
Lengths: 2, 3, 4, 5 or 10 m
Unless otherwise stated prices are per meter.
Hoses in other lengths and quality - please enquire.
98
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
GeoFlex P2 PU (-40°C to +100°C)
Use:
Extraction of wood dust, flour dust
oil and petrol fumes.
Suitable for wood- food- and
pharmaceutical industry.
PUR, antistatic
Art. No.
Description
09-403
09-407
09-408
09-410
09-412
09-412A
09-414
09-415
GeoFlex P2 PU ø50
GeoFlex P2 PU ø80
GeoFlex P2 PU ø100
GeoFlex P2 PU ø125
GeoFlex P2 PU ø150
GeoFlex P2 PU ø160
GeoFlex P2 PU ø200
GeoFlex P2 PU ø250
Weight
Bend
0,30 kg/m
0,46 kg/m
0,51 kg/m
0,65 kg/m
0,78 kg/m
0,84 kg/m
1,05 kg/m
1,25 kg/m
35 mm
56 mm
70 mm
88 mm
105 mm
114 mm
140 mm
175 mm
Weight
Bend
0,27 kg/m
0,32 kg/m
0,38 kg/m
0,44 kg/m
0,54 kg/m
0,65 kg/m
80 mm
100 mm
125 mm
150 mm
250 mm
300 mm
Lengths: 5, 10 or 15 m
GeoFlex High (-40°C to +60°C)
Art. No.
09-007
09-008
09-020
09-009
09-082
09-010
Description
GeoFlex High ø32
GeoFlex High ø38
GeoFlex High ø45
GeoFlex High ø51
GeoFlex High ø64
GeoFlex High ø76
Lengths: per meter, up to 20 m
Use:
Extraction of exhaust, dust, air
and welding smoke.
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
99
Connection pcs. for connecting 2 hoses
Art. No.
57-002
57-003
57-001
57-013
57-004
57-005
Description
Connection piece, ø80 mm
Connection piece, ø100 mm
Connection piece, ø125 mm
Connection piece, ø150 mm
Connection piece, ø160 mm
Connection piece, ø200 mm
Hose clamps
Art. No.
Description
09-033
09-034
09-035
09-036
09-037
Hose Clamps ø77 – 95 mm
Hose Clamps ø87 – 112 mm
Hose Clamps ø104 – 138 mm
Hose Clamps ø130 – 165 mm
Hose Clamps ø200 – 231 mm
01-499
Rubber band ø160-200 black
Quick coupling for medium pressure
Art. No.
100
Description
05-005
05-008
05-006
05-009
Quick coupling 80V for wall mounting
Quick coupling 80L hanging
Quick coupling 100V for wall mounting
Quick coupling 100L hanging
05-011
05-014
05-013
Hose piece for Quick coupling 80V/L
Hose piece for Quick coupling 100V/L
Hose piece 80/100 for Quick coupling 80V/L
06-400
06-401
06-402
06-403
06-404
06-405
Quick coupling 80 VL With end cover
Quick coupling 100 VL With end cover
Quick coupling 125 VL With end cover
Quick coupling 150 VL With end cover
Quick coupling 160 VL With end cover
Quick coupling 200 VL With end cover
06-409
Switch for Quick coupling
06-410
06-411
06-412
06-413
06-414
06-415
Hose piece, 80 VL
Hose piece, 100 VL
Hose piece, 125 VL
Hose piece, 150 VL
Hose piece, 160 VL
Hose piece, 200 VL
91-285
91-286
91-287
91-288
91-289
91-290
Snap lock ø80 VL
Snap lock ø100 VL
Snap lock ø125 VL
Snap lock ø150 VL
Snap lock ø160 VL
Snap lock ø200 VL
07-016A
Hose holder ø100/150 - wall mounted
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Spiro duct
Support Bracket
Ducts
Art. No.
50-002
50-003
50-001
50-004
50-005
50-006
50-007
50-008
07-002
07-003
07-001
07-004
07-005
07-006
07-007
07-008
Spiro duct ø80
Spiro duct ø100
Spiro duct ø125
Spiro duct ø160
Spiro duct ø200
Spiro duct ø250
Spiro duct ø315
Spiro duct ø400
Description
Support Bracket FA-80
Support Bracket FA-100
Support Bracket FA-125
Support Bracket FA-160
Support Bracket FA-200
Support Bracket FA-250
Support Bracket FA-315
Support Bracket FA-400
T-pieces
Art. No.
54-022
54-032
54-033
54-012
54-013
54-011
54-042
54-043
54-015
54-044
54-052
54-053
54-016
54-054
54-055
54-062
54-063
54-017
54-064
54-065
54-066
54-074
54-075
54-076
54-077
54-088
90° bend
45° bend
30° bend
RCL reduction
Bends
Description
Support Bracket
Art. No.
T-piece
Description
T-piece 80-80-80
T-piece 100-80-100
T-piece 100-100-100
T-piece 125-80-125
T-piece 125-100-125
T-piece 125-125-125
T-piece 160-80-160
T-piece 160-100-160
T-piece 160-125-160
T-piece 160-160-160
T-piece 200-80-200
T-piece 200-100-200
T-piece 200-125-200
T-piece 200-160-200
T-piece 200-200-200
T-piece 250-80-250
T-piece 250-100-250
T-piece 250-125-250
T-piece 250-160-250
T-piece 250-200-250
T-piece 250-250-250
T-piece 315-160-315
T-piece 315-200-315
T-piece 315-250-315
T-piece 315-315-315
T-piece 400-400-400
Art. No.
Description
51-002
51-003
51-001
51-004
51-005
51-006
51-007
51-008
90° bend ø80
90° bend ø100
90° bend ø125
90° bend ø160
90° bend ø200
90° bend ø250
90° bend ø315
90° bend ø400
52-002
52-003
52-001
52-004
52-005
52-006
52-007
52-008
45° bend Ø80
45° bend Ø100
45° bend Ø125
45° bend Ø160
45° bend Ø200
45° bend Ø250
45° bend Ø315
45° bend Ø400
53-002
53-003
53-001
53-004
53-005
53-006
53-007
53-008
30° bend ø80
30° bend ø100
30° bend ø125
30° bend ø160
30° bend ø200
30° bend ø250
30° bend ø315
30° bend ø400
Reductions
Art. No.
55-032
55-012
55-013
55-042
55-043
55-041
55-052
55-053
55-051
55-054
55-062
55-063
55-061
55-064
55-065
55-071
55-074
55-075
55-076
55-085
55-086
55-087
Description
RCL reduction 100-80
RCL reduction 125-80
RCL reduction 125-100
RCL reduction 160-80
RCL reduction 160-100
RCL reduction 160-125
RCL reduction 200-80
RCL reduction 200-100
RCL reduction 200-125
RCL reduction 200-160
RCL reduction 250-80
RCL reduction 250-100
RCL reduction 250-125
RCL reduction 250-160
RCL reduction 250-200
RCL reduction 315-125
RCL reduction 315-160
RCL reduction 315-200
RCL reduction 315-250
RCL reduction 400-200
RCL reduction 400-250
RCL reduction 400-315
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
101
Saddle
Conn. nipple
Conn. muff
62-022
62-032
62-033
62-012
62-013
62-011
62-042
62-043
62-041
62-044
62-052
62-053
62-051
62-054
62-055
62-062
62-063
62-061
62-064
62-065
62-066
62-073
62-071
62-074
62-075
62-076
62-077
62-081
62-084
62-085
62-086
62-087
Description
Saddle 80-80
Saddle 100-80
Saddle 100-100
Saddle 125-80
Saddle 125-100
Saddle 125-125
Saddle 160-80
Saddle 160-100
Saddle 160-125
Saddle 160-160
Saddle 200-80
Saddle 200-100
Saddle 200-125
Saddle 200-160
Saddle 200-200
Saddle 250-80
Saddle 250-100
Saddle 250-125
Saddle 250-160
Saddle 250-200
Saddle 250-250
Saddle 315-100
Saddle 315-125
Saddle 315-160
Saddle 315-200
Saddle 315-250
Saddle 315-315
Saddle 400-125
Saddle 400-160
Saddle 400-200
Saddle 400-250
Saddle 400-315
Nipples and muffs
Art. No.
102
End cap MF
Adjustment damper
Shut-off damper
Sliding damper
Nipples and connectors
Saddle
Art. No.
End cap NP
Description
57-002
57-003
57-001
57-004
57-005
57-006
57-007
57-008
Connecting nipple 80
Connecting nipple 100
Connecting nipple 125
Connecting nipple 160
Connecting nipple 200
Connecting nipple 250
Connecting nipple 315
Connecting nipple 400
58-002
58-003
58-001
58-004
58-005
58-006
58-007
58-008
Connecting muff 80
Connecting muff 100
Connecting muff 125
Connecting muff 160
Connecting muff 200
Connecting muff 250
Connecting muff 315
Connecting muff 400
Art. No.
Description
59-002
59-003
59-001
59-004
59-005
59-006
59-007
59-008
End cap nipple 80
End cap nipple 100
End cap nipple 125
End cap nipple 160
End cap nipple 200
End cap nipple 250
End cap nipple 315
End cap nipple 400
60-002
60-003
60-001
60-004
60-005
60-006
60-007
60-008
End cap muff 80
End cap muff 100
End cap muff 125
End cap muff 160
End cap muff 200
End cap muff 250
End cap muff 315
End cap muff 400
Damper
Art. No.
Description
61-002
61-003
61-001
61-004
61-005
61-006
61-007
61-008
Adjustment damper 80
Adjustment damper 100
Adjustment damper 125
Adjustment damper 160
Adjustment damper 200
Adjustment damper 250
Adjustment damper 315
Adjustment damper 400
61-022
61-023
61-021
61-024
61-025
61-026
61-027
61-028
Shut-off damper 80 Tight
Shut-off damper 100 Tight
Shut-off damper 125 Tight
Shut-off damper 160 Tight
Shut-off damper 200 Tight
Shut-off damper 250 Tight
Shut-off damper 315 Tight
Shut-off damper 400 Tight
61-102
61-103
61-101
61-086
61-087
61-106
61-107
Sliding damper 80
Sliding damper 100
Sliding damper 125
Sliding damper 160
Sliding damper 200
Sliding damper 250
Sliding damper 315
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
S ales
and delivery terms
Salgsog leveringsbetingelser
1. Application
These conditions of sale and delivery shall apply to all supplies from GEOVENT A/S, and thus all agreements and trade customs, which are contrary to the conditions, including such conditions as prepared and submitted by the purchaser, are set aside, unless otherwise appears from the order confirmation, as submitted by us.
The conditions are also regarded as accepted for all future business without explicit mentioning it.
2. Conclusion of Agreements
GEOVENT A/S is committed to the statements made by us, no matter how these are described, when we have submitted an order confirmation or effected delivery, at the earliest.
The purchasers are responsible for the correctness of the information and specifi cations of orders, including specifi cations on drawings and similar documents.
3. Power of attorney
No individual person/company, who is agent, representative or broker is empowered to commit GEOVENT A/S without prior written agreement.
4. Prices
All prices according to the price lists, prepared by us, are current prices, excluding VAT, other public duties and transport packaging. We reserve the right to change price lists and
catalogues at any time. In case price increases of more than 5% occur in manufacturing costs and delivery costs as well as in suppliers’ prices, after the conclusion of the agreement
but before delivery, we are entitled to adjust the price regarding such substantiated cost increases. Moreover, the price is based on the current exchange rates at the time of the
conclusion of the agreement. Changes of the exchange rate of more that 5% entitle us to adjust the price accordingly. GEOVENT A/S reserves the right to charge a handling fee of
DKK 100.00 for orders below DKK 500.00.
5. Terms of delivery
Deliveries are made EXW, DK-Løgstrup, in compliance with Incoterms 1990, which means that - when the product is completely finished and ready for delivery, - the purchaser bears
the risk and defrays all costs in connection with the delivery, including the transport costs. In due time, the purchaser is liable to inform GEOVENT A/S of the transport method, which
he intends to make use of. Otherwise, GEOVENT A/S is entitled to select transport method and transport route. In case of delayed delivery, GEOVENT A/S is liable immediately to inform
the purchaser thereof, and the purchaser is entitled to revoke the Agreement and claim compensation, if the delay is of the essence. A delay of the essence does not exist until at
least 30 days after agreed time of delivery. However, the purchaser may not assert the before mentioned rights, if the delay is caused by defaults on the part of the purchaser or on
the part of a sub-supplier. In all cases, the purchaser is not entitled to claim compensation for any indirect loss, including compensation for loss of use and loss of profi ts, and the
purchaser cannot assert any additional rights, either. In case the purchaser does not accept delivery at the time of delivery, including that he fails to perform his collection obligations, then GEOVENT A/S is entitled to revoke the Agreement and claim compensation. Furthermore, GEOVENT A/S is entitled to sell or stock the products for the purchaser’s account.
When storing the products, they are stored at the purchaser’s risk. The return of products and packaging may only take place in accordance with prior, written agreement, and in such
case, the return will be for the purchaser’s account. A return fee of 20% will be charged. Pallets, boxes or other packaging, which is debited separately, will not be credited.
6. Terms of payment
Payment must be made net cash on receipt of the product, where nothing else has been agreed to. For late payments, an interest rate of 1.5% will be calculated per month or fraction
of a month, calculated from date of payment, and until payment is made. The purchaser is not entitled to use the purchase price - or part hereof - for effecting a set-off, just like
the purchaser’s complaint in accordance with article 9 does not entitle the purchaser to retain the purchase price. Products are sold conditionally, which entitles GEOVENT A/S to take
repossession of the products sold, in case the purchaser, - completely or partly, fails to pay. In case the purchaser violates several of the stated obligations, including his obligation in
compliance with article 5, then GEOVENT A/S is entitled to revoke the agreement, sell the products to third party for the purchaser’s account and/or claim compensation.
7. Warranty
The warranty only covers such products, which are proven to be substantially defective or faulty, due to inadequate manufacturing or due to the use of faulty materials, supplied by
GEOVENT A/S. The warranty is only effective, if the products are stored safely, and have been used correctly and in a normal manner by the purchaser in accordance with our specifications. GEOVENT A/S cannot be made responsible for any defects or faults, which occur due to inadequate maintenance, incorrect installation, carried out by the purchaser, for changes
made without our written acceptance, or for repairs, which the purchaser has made in an imperfect way. If products or parts comprise non-GEOVENTmanufacture, then GEOVENT A/S
shall be responsible solely to the extent, that GEOVENT’s supplier has accepted the warranty, irrespective of the provisions stated in this article (article 7). If the product is essentially
defective or faulty, then we are liable to and entitled to - according to our own choice - repair the defect, to implement a replacement supply, to offer a proportional reduction of
the price, or to pay compensation. Transport costs, insurance costs, travelling expenses, installation costs and other costs in connection with the repair or with a replacement supply
are to be paid by the purchaser. Our liability to pay compensation is limited to the invoice price of the defective product, and under no circumstances can we be made liable to pay
compensation for indirect losses, such as compensation for loss of use and loss of profi ts. The warranty does not cover electric cables, hydraulic cables, pneumatic cables, or cables for
extraction, wearing parts or normal wear and tear. The warranty period is one year.
8. Force majeure
GEOVENT A/S is not liable to pay compensation for the failure to perform the obligations, if we can substantiate that this is due to events beyond our control, such as strike, lockout,
export ban or import ban, embargoes, delayed or incomplete deliveries of materials from sub-suppliers, production stop, lack of energy or transport possibilities or due to other types
of force majeure. In such case, we are entitled to prolong the delivery time accordingly or to revoke the Agreement. A hindrance, lasting longer than three months, entitles both parties
to cancel the Agreement.
9. Duty to give notice of defects and duty of inspection
The purchaser is liable to inspect the products, immediately on receipt, and at the latest within eight days after receipt to give notice of any defect. If the purchaser does not observe
these deadlines, then he loses the right to make claims on account of the effect.
10. Product liability
GEOVENT A/S is only liable for personal injury or material damage, caused by our products, in case it can be substantiated that the injury or damage was caused by a mistake or
negligence of a product, supplied by us, and if it is substantiated that the product is defective, that the injury or damage was caused by this defect, and that there is causal relation
between the injury or damage and the defect. Moreover, we are not liable for damage to real or personal property, caused while the product is in the purchaser’s possession, and we
are not liable for damage to any products, manufactured by the purchaser, and which our products are part of, just like we are not liable for any consequential loss, any time restricted
loss of profi ts, any loss of earnings or for other direct losses. In case GEOVENT A/S is imposed liabilities, which exceed the above mentioned, then the purchaser is liable to indemnify
us in this respect. The purchaser is liable to let legal proceedings institute against him at the same court/arbitration as the one dealing with the question about our product liability.
11. Product information
The technical specifi cations and other indicated measurements in catalogues are of guiding character, and GEOVENT A/S accepts no responsibility for errors in this kind of documentation. All information and data, stated in this documentation, including price lists, are only binding to the extent that the Agreement explicitly refers to such specifications.
12. Protection of rights
The purchaser does not obtain any right to the industrial rights of GEOVENT A/S via this present agreement, and the purchaser is unauthorised to using any information about the
product and/or the actual product in such a way that the rights of GEOVENT A/S are violated. The purchaser is responsible for not violating the rights of any third party via the products,
which have been manufactured in compliance with the purchaser’s directions.
13. Drawings and descriptions
All drawings and technical documents regarding the material or the preparation thereof, which previous to, or after the conclusion of the agreement have been left with the purchaser,
belong to GEOVENT A/S and may not be copied, reproduced or handed over to, or in any other way be communicated to any third party, without prior acceptance from GEOVENT A/S.
On request, such material must be returned.
14. Governing law and arbitration
Any disputes, arising in connection with this Agreement, must be settled in accordance with Danish rules of law. In case any dispute cannot be settled out of court, then proceedings
shall be commenced at the venue of GEOVENT A/S.
Geovent A/S assumes no liability for obvious mistakes or printing or spelling errors in this catalogue.
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
103
104
100
1000
Grinding dust rotary
grinder and more
Welding smoke
non-alloyed steel(TIG)
2000
600
200
200
Fumes from organic
solvents and glue
Oil mists, CNC milling machines
Oil mists, conventional
machines
Soldering fumes
Enquire
2000
Exhaust gases
Test stand
Laboratory/hospital
1000
Exhaust gases
Motor > 3000cm²
Depending on size of
cutting table [m2 ]
Laser/plasma cutting
400
-
1500
Welding smoke aluminium (MIG/MAG, TIG)
Exhaust gases motor < 3000 cm²
200
1500
Welding smoke alloyed
steel(MMA, FCA, MIG/
MAG)
Enquire
100
100
160
200
200
150
100
200
1000
200
160
160
28 – 32
80
Hose
dimension
[mm]
Welding smoke
alloyed steel (TIG)
(MMA, FCA, MIG/MAG)
1000
150
Grinding dust bench
grinder/belt grinder
Welding smoke
non-alloyed steel
Air flow per outlet
[m³/h]
Process
Enquire
0,3
0,3
0,3
0,5
-
-
10 - 12
10 – 12
10 – 15
10 – 15
10 – 12
10 – 12
10 – 12
10 – 12
15 – 20
1-2 m/s
at cutting place
-
10 – 15
10 – 15
10 – 15
10 – 15
10 – 15
20 – 25
20 - 25
Air velocity in duct on
unfiltered side [m/s]
0,5
0,5
0,5
0,5
0,5
-
-
Capture velocity
[m/s]
No
No
Yes
Yes
No
No
No
No
5–8
5–8
5–8
5–8
5–8
5–8
5–8
5-8
8 – 10
8 – 10
Yes, depending on
local regulation
Yes
8 – 10
8 – 10
8 – 10
8 – 10
8 – 10
8 - 10
Air velocity in outlet duct
[m/s]
Yes
Yes, depending on
local regulation
Yes, depending on
local regulation
No
Yes
Yes
Filter
necessary
1 m above roof ridge
1 m above roof ridge
1 m above roof ridge
1 m above roof ridge
1 m above roof ridge
2 m above roof ridge
2 m above roof ridge
2 m above roof ridge
2 m above roof ridge
2 m above roof ridge
2 m above roof ridge
2 m above roof ridge
2 m above roof ridge
2 m above roof ridge
2 m above roof ridge
2 m above roof ridge
Chimney height
[m]
Extraction
guide
Punktudsugningsguide
GEOVENT A/S · Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · e-mail: salg@geovent.dk
Application Examples
WWW.GEOVENT.COM
At Geovent we are committed to develop and manufacture components
and systems for process- and comfort ventilation. Our goal is to manufacture
high quality extraction systems with the highest possible efficiency.
The design and ergonomics of our products live up to
statutory market and governmental demands.
Cooperation is the keyword in our efforts to deliver
the best possible solution to satisfy our customers.
Hovedgaden 86 · DK-8831 Løgstrup · Tlf.: (+45) 8664 2211 · Fax: (+45) 8664 3075 · www.geovent.dk · salg@geovent.dk