INSPECTION REPORT For the Property at: 41 PD 161 MENDANALES, NM 87548 Prepared for: SAMPLE REPORT Inspection Date: Monday, May 13, 2013 Prepared by: Howard Stoneback Reality Check Home Inspections HC 65 Box 96 Ojo Sarco, NM 87521 505 689-2392 505 927-2375 howard stoneback hstoneback@hotmail.com Before you buy, before you sell, before you retire, when you need to know. It's time for a reality check. February 8, 2015 Dear Sample Report, RE: Report No. 1071 41 PD 161 Mendanales, NM 87548 Thanks very much for choosing me to perform your home inspection. The inspection itself and the attached report comply with the requirements of the Standards of Practice of our national Association. This document defines the scope of a home inspection. Clients sometimes assume that a home inspection will include many things that are beyond the scope. I encourage you to read the Standards of Practice so that you clearly understand what things are included in the home inspection and report. The report has been prepared for the exclusive use of our client. No use by third parties is intended. I will not be responsible to any parties for the contents of the report, other than the party named herein . The report is effectively a snapshot of the house, recording the conditions on a given date and time. Home inspectors cannot predict future behavior, and as such, I cannot be responsible for things that occur after the inspection. If conditions change, I are available to revisit the property and update our report. The report itself is copyrighted, and may not be used in whole or in part without my express written permission. Again, thanks very much for choosing us to perform your home inspection. I offer a full satisfaction guarantee, and will return your fee in full if you are not satisfied at any time. Sincerely, Howard Stoneback on behalf of Reality Check Home Inspections Reality Check Home Inspections HC 65 Box 96 Ojo Sarco, NM 87521 505 689-2392 505 927-2375 howard stoneback hstoneback@hotmail.com Report No. 1071 SUMMARY 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR This Summary outlines potentially significant issues from a cost or safety standpoint. This section is provided as a courtesy and cannot be considered a substitute for reading the entire report. Please read the complete document. Priority Maintenance Items Roofing FLAT ROOFING \ Modified bitumen Condition: Cracked There are some cracks in the roof membrane which are signs of age and sun damage, recommend maintenance to roof surface to improve condition and to help prolong life of roofing materials. Implication(s): Chance of water damage to contents, finishes and/or structure Location: Various Roof Task: Maintenance Time: Less than 1 year Condition: Loss of granules The granules and roof white coating on modified bitumen roof has deteriorated. This is the UV protection for roof membrane. Adding additional UV protection and maintenance will help prolong life of roof. The remaining life of is undetermined recommend having roof evaluated and budgeting for replacing in 5 to 10 years. Implication(s): Chance of water damage to contents, finishes and/or structure Location: Throughout Roof Task: Maintenance Time: Less than 1 year Exterior ROOF DRAINAGE \ Flat roof drains Condition: The canale drainage system on roof is minimal. recommend regular maintenance and monitoring to assure drains are clear of debris and functional. Location: Various Roof Task: Maintenance Time: Ongoing WALLS \ Trim Condition: Paint or stain needed Some exterior wood needs stain or sealer, recommend maintenance to help prolong life of wood trim and to help prevent moisture issues. Location: Various Exterior Wall Task: Maintenance Time: Less than 1 year WALLS \ Stucco and EIFS Condition: Minor cracks There are minor cracks in exterior plaster (this is common with stucco), recommend monitoring cracks to be sure they don't get too larger and cause water issues. Repairs and maintenance to seal these cracks will help prevent future issues, special attention need on tops of parapet walls. Providing great home inspections for every client every time Page 1 of 31 Report No. 1071 SUMMARY 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Implication(s): Cosmetic defects | Shortened life expectancy of material Location: Various Exterior Wall Task: Maintenance Time: Less than 1 year DOORS \ Doors and frames Condition: The wood exterior doors have deteriorated finish and have cracks in wood which need maintenance. These are interior doors which do not give adequate protection from weather or for security, recommend replacing with exterior doors (1 3/4" thick) Location: Various Exterior Wall Hall Task: Repair or replace Time: Discretionary DOORS \ Exterior trim Condition: Rot or insect damage Some exterior door trim has damage and needs to be replaced, also there is deteriorated finish on wood trim. Recommend repairs and maintenance to help prolong life of wood and to help prevent moisture issues. Implication(s): Chance of damage to finishes and structure | Material deterioration Location: Various Exterior Wall Task: Repair or replace Time: Discretionary PORCHES, DECKS, STEPS, PATIOS AND BALCONIES \ Floors Condition: Paint or stain needed The wood deck and railings have deteriorated finish, recommend periodic maintenance to help prolong life of wood. Also wood deck sits on top of roof membrane, recommend monitoring the contact points for wear to prevent moisture issues and leaks. Implication(s): Cosmetic defects | Shortened life expectancy of material Location: South Second Floor Deck Task: Maintenance Time: Discretionary PORCHES, DECKS, STEPS, PATIOS AND BALCONIES \ Roof structure Condition: The wooden shade cover on rear patio has deteriorated finish and some damaged wood, recommend maintenance to help prolong life of wood. Location: Rear Exterior Task: Maintenance Time: Discretionary GARAGE \ Vehicle door operators Condition: Garage door opener is operational, but to close one has to push and hold button or door will reverse. This may be caused by maladjustment of sensors or reverser. or switch in opener. Recommend having unit serviced or making adjustments. Location: Front Exterior Wall Garage Task: Repair or replace Time: Discretionary Providing great home inspections for every client every time Page 2 of 31 Report No. 1071 SUMMARY 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Structure FOUNDATIONS \ Performance opinion Condition: No defects noted No issues were visible. Location: Throughout Exterior Wall Task: Monitor Time: Discretionary WALLS \ Wood frame walls Condition: No framing issues noted. Location: Throughout Exterior Wall Task: Monitor Time: Discretionary ROOF FRAMING \ Rafters/trusses Condition: No roof frame issues noted. Location: Throughout Roof Task: Monitor Time: Discretionary Electrical DISTRIBUTION SYSTEM \ Outlets (receptacles) Condition: GFI test faulty Some GFCI were hard to reset from lack of use or sealing over with tile sealer. Recommend repairs or replacing GFCI receptacles as needed. Implication(s): Electric shock Location: Various Kitchen Task: Further evaluation Time: Discretionary DISTRIBUTION SYSTEM \ Smoke detectors Condition: Some smoke detectors are missing and some need batteries, recommend repairs and maintenance to assure proper use and safety function. Location: Throughout Task: Service Time: Less than 1 year DISTRIBUTION SYSTEM \ Carbon monoxide (CO) detectors Condition: None Recommend CO detectors where gas appliances and fireplaces are in use as safety precaution. Implication(s): Health hazard Location: First Floor Living Room Task: Upgrade Time: Discretionary Providing great home inspections for every client every time Page 3 of 31 Report No. 1071 SUMMARY 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Heating GAS FURNACE \ Life expectancy Condition: The water heater/boiler in garage used for heating in older part of house has seen many years of use and the boiler for addition appears serviceable. Recommend periodic maintenance to assure safe and efficient use and to help prolong life of units. Garage WH unit has undetermined life, recommend budgeting for replacing is necessary. Location: North Garage Task: Service Time: Discretionary CHIMNEY AND VENT \ Inspect/sweep chimney Condition: Inspect (and/sweep if needed) before using Recommend periodic inspection and cleaning of fireplaces and chimneys to assure safe and efficient use. Implication(s): Fire hazard Location: Various Living Room Task: Maintenance Time: Discretionary Cooling & Heat Pump AIR CONDITIONING \ Evaporative cooler Condition: Water supply line defective The water lines were removed and need replacing. The evaporative coolers need to be cleaned and serviced before seasonal use. Replacing the cooler pads periodically will improve interior air quality and help unit run more efficiently. While units were winterized and not operational at time of inspection they appeared used but functional, recommend seasonal maintenance to manufacturers specifications. Location: Various Roof Task: Repair or replace Time: Less than 1 year Insulation and Ventilation RECOMMENDATIONS \ Overview Condition: No insulation recommendations are offered as a result of this inspection. Insulation not visible, insulation appeared serviceable, if needed check with builder or plans for values. Location: Throughout Exterior Wall Task: Monitor Time: Discretionary ATTIC/ROOF \ Roof vents Condition: Inadequate The roof ventilation is minimal in addition and older roof doesn't have vents, this causes the roof materials to heat and can cause defect such as cracking. Recommend adding roof vents to help prolong life of roof and to prevent overheating and moisture issues in the roof framing. Implication(s): Chance of condensation damage to finishes and/or structure Providing great home inspections for every client every time Page 4 of 31 Report No. 1071 SUMMARY 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Location: Various Roof Task: Upgrade Time: Discretionary Plumbing RECOMMENDATIONS \ Overview Condition: Well equipment appeared serviceable and well house is in good condition. Location: Rear Exterior Task: Monitor Time: Discretionary WATER HEATER \ Life expectancy Condition: Water heater in garage for older part of house has unknown remaining life, this unit appears to be about 18 yrs. old. recommend budgeting for replacement. Location: Garage Task: Service Time: Discretionary WATER HEATER \ Tank Condition: The water heater to addition is a tank and separate zone combination with boiler. It appears the pump to tank or switch which controls pump is in need of repair or replacing, recommend having unit serviced so boiler will heat water in tank for domestic hot water in addition. Location: Furnace Room Task: Service Time: Less than 1 year FIXTURES AND FAUCETS \ Basin, sink and laundry tub Condition: Leak Sink drains in both bathrooms of addition are leaking recommend repairs to prevent moisture issues. Implication(s): Chance of water damage to contents, finishes and/or structure | Sewage entering the building Location: Various Bathroom Task: Maintenance Time: Less than 1 year FIXTURES AND FAUCETS \ Faucet Condition: There is no water in hall bathroom vanity, recommend maintenance to correct. Location: Center Bathroom Task: Correct Time: Less than 1 year FIXTURES AND FAUCETS \ Shower stall Condition: Leak Shower pan in bathroom in addition has leak, recommend caulking or repairing the pan to prevent further moisture issues. Water is leaking through wall and across hall, check for wood damage before sealing. Implication(s): Chance of water damage to contents, finishes and/or structure Location: Southwest First Floor Bathroom Providing great home inspections for every client every time Page 5 of 31 Report No. 1071 SUMMARY 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Task: Repair or replace Time: Immediate FIXTURES AND FAUCETS \ Shower stall enclosure Condition: Electrical problems at the enclosure There is an electric wire in upstairs shower for unknown reason (never installed appliance or tub. This wire is not connected in electric panel, recommend repairs for visual and potential safety issues. Implication(s): Electric shock Location: Second Floor Bathroom Task: Correct Time: Discretionary WATER TREATMENT \ System Condition: There is a sand trap in well house , recommend periodic servicing to clean and assure proper function. As a future upgrade recommend adding filter to help keep sand and minerals from well from getting into system. Location: Rear Task: Upgrade Time: Discretionary Interior FLOORS \ Ceramic tile, stone, marble, etc Condition: There are stains on the brick floor which are from previous water leak. Cleaning and sealing bricks should correct visible staining. Location: First Floor Laundry Area Task: Maintenance Time: Discretionary Condition: Tiles cracked There are minor cracks is tile that are cosmetic, repairs can be made if desired. By monitoring minor cracks one can determine of there is any movement or settling, slab appears stable. Implication(s): Cosmetic defects | Trip or fall hazard Location: Various Task: Monitor Time: Discretionary WALLS \ Plaster or drywall Condition: Typical flaws There are minor cracks and defects, maintenance to these areas would improve appearance of interior. There are cosmetic damage in many places and also some trim missing, recommend repairs and maintenance. Implication(s): Cosmetic defects Location: Various Hall Task: Maintenance Time: Discretionary WINDOWS \ Sashes Condition: Poor weatherstripping Providing great home inspections for every client every time Page 6 of 31 Report No. 1071 SUMMARY 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Weather-stripping on window is old and worn in some places, recommend replacing or repairs as needed. Manufacture has replacement weather stripping as general rule. Implication(s): Chance of damage to finishes and structure Location: Various Exterior Wall Task: Repair or replace Time: Discretionary WINDOWS \ Frames Condition: The interior wood on windows has limited finish on the wood on frames and sash, recommend cleaning and adding finish to help prolong life of wood and window units. Location: Various Exterior Wall Task: Maintenance Time: Discretionary DOORS \ Hardware Condition: Inoperable Some exterior dead bolts and hardware are not properly functioning, recommend repairs or replacing hardware. Implication(s): System inoperative or difficult to operate Location: Various Exterior Wall Task: Repair or replace Time: When necessary CARPENTRY \ Cabinets Condition: Doors or drawers missing or loose Some of the drawer slides are old and not functioning properly, recommend repairs as needed. Implication(s): Cosmetic defects Location: Various Kitchen Task: Repair or replace Time: Discretionary CARPENTRY \ Countertops Condition: Tiles loose, missing, cracked, stained or broken Some of the kitchen tile is loose with deteriorated grout, recommenced maintenance to help prevent moisture and health reasons. Implication(s): Cosmetic defects | Hygiene issue Location: Kitchen Task: Repair or replace Time: Discretionary GARAGE \ Vehicle door operators Condition: Adjustment needed to open or close limits Garage door opener not closing door properly, recommend repairs or replacing for normal use. Implication(s): Equipment not operating properly Location: Front Exterior Wall Garage Task: Repair or replace Time: Discretionary Providing great home inspections for every client every time Page 7 of 31 Report No. 1071 SUMMARY 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR APPLIANCES \ Range Condition: Inoperative The gas burners not operating, recommend servicing to assure proper function. Implication(s): System inoperative Location: Kitchen Task: Service Time: Discretionary APPLIANCES \ Microwave oven Condition: Inoperative Microwave oven not functioning properly, not plugged in. Recommend servicing for proper use. Implication(s): Equipment inoperative Location: Kitchen Task: Further evaluation Time: Discretionary This concludes the Summary section. The remainder of the report describes each of the home's systems and also details any recommendations we have for improvements. Limitations that restricted our inspection are included as well. The suggested time frames for completing recommendations are based on the limited information available during a pre-purchase home inspection. These may have to be adjusted based on the findings of specialists. Home Improvement - ballpark costs Providing great home inspections for every client every time Page 8 of 31 Report No. 1071 ROOFING 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Description Flat roofing material: Modified bitumen Polyurethane foam Limitations Inspection performed: By walking on roof Recommendations FLAT ROOFING \ Modified bitumen Condition: Cracked There are some cracks in the roof membrane which are signs of age and sun damage, recommend maintenance to roof surface to improve condition and to help prolong life of roofing materials. Implication(s): Chance of water damage to contents, finishes and/or structure Location: Various Roof Task: Maintenance Time: Less than 1 year 1. Cracked Condition: Loss of granules The granules and roof white coating on modified bitumen roof has deteriorated. This is the UV protection for roof membrane. Adding additional UV protection and maintenance will help prolong life of roof. The remaining life of is undetermined recommend having roof evaluated and budgeting for replacing in 5 to 10 years. Implication(s): Chance of water damage to contents, finishes and/or structure Location: Throughout Roof Task: Maintenance Time: Less than 1 year Providing great home inspections for every client every time Page 9 of 31 Report No. 1071 ROOFING 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL 2. Loss of granules HEATING COOLING INSULATION PLUMBING INTERIOR 3. Loss of granules 4. Loss of granules Providing great home inspections for every client every time Page 10 of 31 Report No. 1071 EXTERIOR 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Description Gutter & downspout material: Galvanized steel Gutters no downs Gutter & downspout discharge: Above grade Above grade Lot slope: Away from building Flat Gentle slope rear to front Wall surfaces: Stucco Soffit and fascia: Wood Driveway: Gravel Walkway: Concrete Deck: Wood Patio: Pavers Fence: Stucco Gravel Pavers Gravel Crushed stone Stucco covered masonry Garage: General Attached garage Recommendations ROOF DRAINAGE \ Flat roof drains Condition: The canale drainage system on roof is minimal. recommend regular maintenance and monitoring to assure drains are clear of debris and functional. Location: Various Roof Task: Maintenance Time: Ongoing Providing great home inspections for every client every time Page 11 of 31 Report No. 1071 EXTERIOR 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 5. WALLS \ Trim Condition: Paint or stain needed Some exterior wood needs stain or sealer, recommend maintenance to help prolong life of wood trim and to help prevent moisture issues. Location: Various Exterior Wall Task: Maintenance Time: Less than 1 year WALLS \ Stucco and EIFS Condition: Minor cracks There are minor cracks in exterior plaster (this is common with stucco), recommend monitoring cracks to be sure they don't get too larger and cause water issues. Repairs and maintenance to seal these cracks will help prevent future issues, special attention need on tops of parapet walls. Implication(s): Cosmetic defects | Shortened life expectancy of material Location: Various Exterior Wall Task: Maintenance Time: Less than 1 year Providing great home inspections for every client every time Page 12 of 31 Report No. 1071 EXTERIOR 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 6. Minor cracks DOORS \ Doors and frames Condition: The wood exterior doors have deteriorated finish and have cracks in wood which need maintenance. These are interior doors which do not give adequate protection from weather or for security, recommend replacing with exterior doors (1 3/4" thick) Location: Various Exterior Wall Hall Task: Repair or replace Time: Discretionary 7. DOORS \ Exterior trim Condition: Rot or insect damage Some exterior door trim has damage and needs to be replaced, also there is deteriorated finish on wood trim. Recommend repairs and maintenance to help prolong life of wood and to help prevent moisture issues. Implication(s): Chance of damage to finishes and structure | Material deterioration Location: Various Exterior Wall Task: Repair or replace Providing great home inspections for every client every time Page 13 of 31 Report No. 1071 EXTERIOR 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Time: Discretionary 8. Rot or insect damage PORCHES, DECKS, STEPS, PATIOS AND BALCONIES \ Floors Condition: Paint or stain needed The wood deck and railings have deteriorated finish, recommend periodic maintenance to help prolong life of wood. Also wood deck sits on top of roof membrane, recommend monitoring the contact points for wear to prevent moisture issues and leaks. Implication(s): Cosmetic defects | Shortened life expectancy of material Location: South Second Floor Deck Task: Maintenance Time: Discretionary 9. Paint or stain needed PORCHES, DECKS, STEPS, PATIOS AND BALCONIES \ Roof structure Condition: The wooden shade cover on rear patio has deteriorated finish and some damaged wood, recommend maintenance to help prolong life of wood. Location: Rear Exterior Task: Maintenance Providing great home inspections for every client every time Page 14 of 31 Report No. 1071 EXTERIOR 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Time: Discretionary 10. GARAGE \ Vehicle door operators Condition: Garage door opener is operational, but to close one has to push and hold button or door will reverse. This may be caused by maladjustment of sensors or reverser. or switch in opener. Recommend having unit serviced or making adjustments. Location: Front Exterior Wall Garage Task: Repair or replace Time: Discretionary 11. Providing great home inspections for every client every time Page 15 of 31 Report No. 1071 STRUCTURE 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Description Configuration: Slab-on-grade Foundation material: Floor construction: Poured concrete Insulating concrete forms Concrete Exterior wall construction: Roof and ceiling framing: Wood frame Rafters/roof joists Recommendations FOUNDATIONS \ Performance opinion Condition: No defects noted No issues were visible. Location: Throughout Exterior Wall Task: Monitor Time: Discretionary 12. No defects noted WALLS \ Wood frame walls Condition: No framing issues noted. Location: Throughout Exterior Wall Task: Monitor Time: Discretionary ROOF FRAMING \ Rafters/trusses Condition: No roof frame issues noted. Location: Throughout Roof Task: Monitor Time: Discretionary Providing great home inspections for every client every time Page 16 of 31 Report No. 1071 ELECTRICAL 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Description Service entrance cable and location: Service size: Underground aluminum 200 Amps (240 Volts) Main disconnect/service box rating: 200 Amps Main disconnect/service box type and location: Breakers -exterior wall At meter next to garage door. System grounding material and type: Distribution panel rating: Copper - ground rods Not visible 200 Amps Distribution panel type and location: Breakers - garage Auxiliary panel (subpanel) type and location: Breakers - first floor West end of addition on interior wall Auxiliary panel (subpanel) rating: Distribution wire material and type: 50 amp main breaker in sub panel Copper - non-metallic sheathed Circuit interrupters: Ground Fault (GFCI) & Arc Fault (AFCI): GFCI - kitchen Smoke detectors: GFCI - bathroom GFCI - outside GFCI - garage Present Carbon monoxide (CO) detectors: None noted Recommendations DISTRIBUTION SYSTEM \ Outlets (receptacles) Condition: GFI test faulty Some GFCI were hard to reset from lack of use or sealing over with tile sealer. Recommend repairs or replacing GFCI receptacles as needed. Implication(s): Electric shock Location: Various Kitchen Task: Further evaluation Time: Discretionary DISTRIBUTION SYSTEM \ Smoke detectors Condition: Some smoke detectors are missing and some need batteries, recommend repairs and maintenance to assure proper use and safety function. Location: Throughout Task: Service Time: Less than 1 year DISTRIBUTION SYSTEM \ Carbon monoxide (CO) detectors Condition: None Recommend CO detectors where gas appliances and fireplaces are in use as safety precaution. Implication(s): Health hazard Providing great home inspections for every client every time Page 17 of 31 Report No. 1071 ELECTRICAL 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Location: First Floor Living Room Task: Upgrade Time: Discretionary Providing great home inspections for every client every time Page 18 of 31 Report No. 1071 HEATING 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Description Fuel/energy source: Propane Boiler manufacturer: State Censible 5102 water heater is original boiler in older parts of the house. Boiler manufacturer: Laars Mini-Therm II boiler for addition/south wing Heat distribution: Hot water radiant piping Radiant floor heating Approximate capacity: Efficiency: 120,000 BTU/hr Conventional Approximate age: 12 years Main fuel shut off at: 19 years Propane tank Exhaust pipe (vent connector): Fireplace: Double wall Wood-burning fireplace Chimney/vent: Masonry Chimney liner: Clay Combustion air source: Interior of building Fire places use interior air for combustion Outside Boiler uses outside air, water heaters use air from garage (which is vented) Recommendations GAS FURNACE \ Life expectancy Condition: The water heater/boiler in garage used for heating in older part of house has seen many years of use and the boiler for addition appears serviceable. Recommend periodic maintenance to assure safe and efficient use and to help prolong life of units. Garage WH unit has undetermined life, recommend budgeting for replacing is necessary. Location: North Garage Task: Service Time: Discretionary Providing great home inspections for every client every time Page 19 of 31 Report No. 1071 HEATING 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 13. CHIMNEY AND VENT \ Inspect/sweep chimney Condition: Inspect (and/sweep if needed) before using Recommend periodic inspection and cleaning of fireplaces and chimneys to assure safe and efficient use. Implication(s): Fire hazard Location: Various Living Room Task: Maintenance Time: Discretionary 14. Unlined chimney flue Providing great home inspections for every client every time Page 20 of 31 Report No. 1071 COOLING & HEAT PUMP 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Description Air conditioning type: Evaporative cooler 2 roof mounted evaporative coolers Evaporative cooler motor: Evaporative coolers we're winterized and not operational. Recommendations AIR CONDITIONING \ Evaporative cooler Condition: Water supply line defective The water lines were removed and need replacing. The evaporative coolers need to be cleaned and serviced before seasonal use. Replacing the cooler pads periodically will improve interior air quality and help unit run more efficiently. While units were winterized and not operational at time of inspection they appeared used but functional, recommend seasonal maintenance to manufacturers specifications. Location: Various Roof Task: Repair or replace Time: Less than 1 year 15. Water supply line defective Providing great home inspections for every client every time Page 21 of 31 Report No. 1071 INSULATION AND VENTILATION 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Description Attic/roof insulation material: Glass fiber Insulation not visible, fiber glass is commonly used at time of construction. Attic/roof insulation amount/value: Not determined R-28 to R-38 is common practice Attic/roof ventilation: Roof vent Attic/roof air/vapor barrier: Wall insulation material: Not visible Glass fiber Wall insulation amount/value: R-20 Foundation wall insulation material: Foam forms visible in garage foundation Recommendations RECOMMENDATIONS \ Overview Condition: No insulation recommendations are offered as a result of this inspection. Insulation not visible, insulation appeared serviceable, if needed check with builder or plans for values. Location: Throughout Exterior Wall Task: Monitor Time: Discretionary ATTIC/ROOF \ Roof vents Condition: Inadequate The roof ventilation is minimal in addition and older roof doesn't have vents, this causes the roof materials to heat and can cause defect such as cracking. Recommend adding roof vents to help prolong life of roof and to prevent overheating and moisture issues in the roof framing. Implication(s): Chance of condensation damage to finishes and/or structure Location: Various Roof Task: Upgrade Time: Discretionary Providing great home inspections for every client every time Page 22 of 31 Report No. 1071 INSULATION AND VENTILATION SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Click on image to enlarge. 41 PD 161, Mendanales, NM Providing great home inspections for every client every time Page 23 of 31 Report No. 1071 PLUMBING 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Description Water supply source: Private Service piping into building: Plastic Supply piping in building: PEC piping Supply piping in building: Copper Main water shut off valve at the: Shut in well house. Main water shut off valve at the: Utility room Water flow and pressure: Above average Water heater fuel/energy source: Water heater type: Tank capacity: Conventional 40 gallons Water heater approximate age: Typical life expectancy: Waste piping in building: Gas piping: Propane 18 years 8 to 12 years PVC plastic Steel Recommendations RECOMMENDATIONS \ Overview Condition: Well equipment appeared serviceable and well house is in good condition. Location: Rear Exterior Task: Monitor Time: Discretionary 16. WATER HEATER \ Life expectancy Condition: Water heater in garage for older part of house has unknown remaining life, this unit appears to be about 18 Providing great home inspections for every client every time Page 24 of 31 Report No. 1071 PLUMBING 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR yrs. old. recommend budgeting for replacement. Location: Garage Task: Service Time: Discretionary WATER HEATER \ Tank Condition: The water heater to addition is a tank and separate zone combination with boiler. It appears the pump to tank or switch which controls pump is in need of repair or replacing, recommend having unit serviced so boiler will heat water in tank for domestic hot water in addition. Location: Furnace Room Task: Service Time: Less than 1 year 17. FIXTURES AND FAUCETS \ Basin, sink and laundry tub Condition: Leak Sink drains in both bathrooms of addition are leaking recommend repairs to prevent moisture issues. Implication(s): Chance of water damage to contents, finishes and/or structure | Sewage entering the building Location: Various Bathroom Task: Maintenance Time: Less than 1 year Providing great home inspections for every client every time Page 25 of 31 Report No. 1071 PLUMBING 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 18. Leak FIXTURES AND FAUCETS \ Faucet Condition: There is no water in hall bathroom vanity, recommend maintenance to correct. Location: Center Bathroom Task: Correct Time: Less than 1 year FIXTURES AND FAUCETS \ Shower stall Condition: Leak Shower pan in bathroom in addition has leak, recommend caulking or repairing the pan to prevent further moisture issues. Water is leaking through wall and across hall, check for wood damage before sealing. Implication(s): Chance of water damage to contents, finishes and/or structure Location: Southwest First Floor Bathroom Task: Repair or replace Time: Immediate FIXTURES AND FAUCETS \ Shower stall enclosure Condition: Electrical problems at the enclosure There is an electric wire in upstairs shower for unknown reason (never installed appliance or tub. This wire is not connected in electric panel, recommend repairs for visual and potential safety issues. Implication(s): Electric shock Location: Second Floor Bathroom Task: Correct Time: Discretionary Providing great home inspections for every client every time Page 26 of 31 Report No. 1071 PLUMBING 41 PD 161, Mendanales, NM ROOFING EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Click on image to enlarge. SUMMARY howard stoneback May 13, 2013 WATER TREATMENT \ System Condition: There is a sand trap in well house , recommend periodic servicing to clean and assure proper function. As a future upgrade recommend adding filter to help keep sand and minerals from well from getting into system. Location: Rear Task: Upgrade Time: Discretionary Providing great home inspections for every client every time Page 27 of 31 Report No. 1071 INTERIOR 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Description Major floor finishes: Red brick Major floor finishes: Tile Major wall finishes: Plaster/drywall Major ceiling finishes: Windows: Glazing: Fixed Wood Fixed Casement Skylight Vinyl-clad wood Double Exterior doors - type/material: Hinged French Vinyl clad wood Wood Metal Garage door - metal Garage Doors: Inspected Oven type: Conventional Range fuel: Propane Appliances: Range hood Laundry facilities: Convection Dishwasher Hot/cold water supply Microwave oven Vented to outside 120-Volt outlet 240-Volt outlet Waste standpipe Kitchen ventilation: Exhaust fan Down draft range Range hood Micro hood Bathroom ventilation: Stairs and railings: Exhaust fan Inspected Recommendations FLOORS \ Ceramic tile, stone, marble, etc Condition: There are stains on the brick floor which are from previous water leak. Cleaning and sealing bricks should correct visible staining. Location: First Floor Laundry Area Task: Maintenance Time: Discretionary Condition: Tiles cracked There are minor cracks is tile that are cosmetic, repairs can be made if desired. By monitoring minor cracks one can determine of there is any movement or settling, slab appears stable. Implication(s): Cosmetic defects | Trip or fall hazard Providing great home inspections for every client every time Page 28 of 31 Report No. 1071 INTERIOR 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Location: Various Task: Monitor Time: Discretionary WALLS \ Plaster or drywall Condition: Typical flaws There are minor cracks and defects, maintenance to these areas would improve appearance of interior. There are cosmetic damage in many places and also some trim missing, recommend repairs and maintenance. Implication(s): Cosmetic defects Location: Various Hall Task: Maintenance Time: Discretionary WINDOWS \ Sashes Condition: Poor weatherstripping Weather-stripping on window is old and worn in some places, recommend replacing or repairs as needed. Manufacture has replacement weather stripping as general rule. Implication(s): Chance of damage to finishes and structure Location: Various Exterior Wall Task: Repair or replace Time: Discretionary 19. Poor weatherstripping WINDOWS \ Frames Condition: The interior wood on windows has limited finish on the wood on frames and sash, recommend cleaning and adding finish to help prolong life of wood and window units. Location: Various Exterior Wall Task: Maintenance Time: Discretionary DOORS \ Hardware Condition: Inoperable Some exterior dead bolts and hardware are not properly functioning, recommend repairs or replacing hardware. Providing great home inspections for every client every time Page 29 of 31 Report No. 1071 INTERIOR 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Implication(s): System inoperative or difficult to operate Location: Various Exterior Wall Task: Repair or replace Time: When necessary CARPENTRY \ Cabinets Condition: Doors or drawers missing or loose Some of the drawer slides are old and not functioning properly, recommend repairs as needed. Implication(s): Cosmetic defects Location: Various Kitchen Task: Repair or replace Time: Discretionary CARPENTRY \ Countertops Condition: Tiles loose, missing, cracked, stained or broken Some of the kitchen tile is loose with deteriorated grout, recommenced maintenance to help prevent moisture and health reasons. Implication(s): Cosmetic defects | Hygiene issue Location: Kitchen Task: Repair or replace Time: Discretionary 20. Tiles loose, missing, cracked, stained or... GARAGE \ Vehicle door operators Condition: Adjustment needed to open or close limits Garage door opener not closing door properly, recommend repairs or replacing for normal use. Implication(s): Equipment not operating properly Location: Front Exterior Wall Garage Task: Repair or replace Time: Discretionary APPLIANCES \ Range Condition: Inoperative Providing great home inspections for every client every time Page 30 of 31 Report No. 1071 INTERIOR 41 PD 161, Mendanales, NM SUMMARY ROOFING howard stoneback May 13, 2013 EXTERIOR STRUCTURE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR The gas burners not operating, recommend servicing to assure proper function. Implication(s): System inoperative Location: Kitchen Task: Service Time: Discretionary 21. Inoperative APPLIANCES \ Microwave oven Condition: Inoperative Microwave oven not functioning properly, not plugged in. Recommend servicing for proper use. Implication(s): Equipment inoperative Location: Kitchen Task: Further evaluation Time: Discretionary END OF REPORT Providing great home inspections for every client every time Page 31 of 31