Test Report ------------------------------------------------------------------------------- 1/13 Report No. R2015060373 Specifications Test Method FCC Part 15.109(g), CISPR 22, Class A ANSI C63.4, ICES-003 Applicant Applicant address Edimax Technology Co., Ltd. No. 3, Wu-Chuan 3rd Road, Wu-Ku Industrial Park Taipei Hsien, Taiwan. Items tested Trade Name Model No. Sample No. Gigabit Ethernet Switch Edimax ES-516G+, ES-524G+ R20050153 Results Date Compliance (As detailed within this report) 02/22/2005 (month / day / year)(Sample received) 03/04/2005 (month / day / year)(Tested) Prepared by Project Engineer Authorized by V. General Manager (Jacob Lin) (month / day / year) Issue date Modifications Tested by Office at Open site at July 05, 2006 None Training Research Co., Ltd. (Accredited by NVLAP) 1F, No. 255, Nan Yang Street, Hsichih, Taipei Hsien 221, Taiwan No. 15, Lane 530, Pa-Lian RD., Sec. 1, Hsichih City, Taipei Hsien, Taiwan, R.O.C.. Conditions of issue : z This test report shall not be reproduced except in full, without written approval of TRC. And the test result contained within this report only relate to the sample submitted for testing. z The test data in this test report are following the procedures in accordance with the terms of accreditation. z This test report and measurements made by TRC are traceable to the NIST only Conducted and Radiated Method (TRC is accredited by NVLAP, code No.: 200174-0). z The device has been tested is fully complied with the requirements the Directive FCC Part 15. Report No.: R2015060373 Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778 Test Report ------------------------------------------------------------------------------- 2/13 Contents Chapter 1 Introduction Description of EUT ................................................................................................................... 3 Configuration of Test Setup ...................................................................................................... 4 List of Support Equipment ........................................................................................................ 5 Chapter 2 Conducted Emission Test Test Condition and Setup .......................................................................................................... 7 Conducted Test Placement ........................................................................................................ 8 Chapter 3 Radiated Emission Test Test Condition and Setup .......................................................................................................... 9 Radiated Test Placement .......................................................................................................... 10 Appendix A : Conducted test result ................................................................................................................ 11 Appendix B : Radiated test result ................................................................................................................... 13 Report No.: R2015060373 Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778 Test Report ------------------------------------------------------------------------------- 3/13 Chapter 1 Introduction Description of EUT: The EUT has two parts, and have two model numbers, they are ES-516G+ and ES-524G+, features as below: ES-524G+ : 24-Port Gigabit Ethernet Web-Smart Switch ES-516G+ : 16-Port Gigabit Ethernet Web-Smart Switch z z z z Transmission Mode: 10/100Mbps support full or half duplex, 1000Mbps support full duplex only. Transmission Speed: 10/100/1000Mbps for TP, 1000Mbps for Fiber MAC Address: 8K MAC address and 4K VLAN support Buffer Memory: 400KB on-chip frame buffer z Flow Control: IEEE802.3x compliant for full duplex, Backpressure flow control for half duplex 24-Port Gigabit Ethernet Switch and 16-Port Gigabit Ethernet Switch PCB design are the same, only with different amount of UTP plugs. There have been verified over each test item, and we only recorded the 24-Port Gigabit Ethernet Switch test results in the test report. Test method: Pretest was found that the emission of operating mode is worse than standby mode. So, The final test is made at the operating mode. During testing, the EUT was operated at “transmitting” and “receiving” mode simultaneously. During testing, there are four modes were tested: #1 24-Port Gigabit Ethernet Switch 1Gbps x 1Gbps #2 24-Port Gigabit Ethernet Switch 10Mbps x 100Mbps #3 16-Port Gigabit Ethernet Switch 1Gbps x 1Gbps #4 16-Port Gigabit Ethernet Switch 10Mbps x 100Mbps The radiation pretest was found out the testing mode: “#1 24-Port Gigabit Ethernet Switch 1Gbps x 1Gbps” was the worst case. We only recorded worse case in this report. The test voltage is 230Vac/ 50Hz. The test placement as the photographs showed is the worst emission placed. (If the emission is close to the ambient, the resolution BW and view resolution will be reduced and the data will be recorded by detection of maximum hold peak mode.) The testing configuration of test setup is showing in the next page. Report No.: R2015060373 Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778 Test Report ------------------------------------------------------------------------------- 4/13 Configuration of test setup Power Source Monitor Modem EUT Fiber LAN Card Printer PC To PC LAN Port Located Remotely Keyboard Mouse USB Mouse USB Joystick Located Remotely Connections: PC: *Serial Port --- via a 110cm shielded RS-232 cable to modem. *Monitor Port --- a monitor with 1.5m length data cable. *Keyboard port --- a keyboard with 1.50m length data cable. *Mouse port --- a mouse with 1.50m length data cable. *USB port A --- a USB joystick with 1.5m long, shielded, no ferrite bead data cable. *USB port B --- a USB mouse with 1.8m long, shielded, no ferrite bead data cable. *Printer port --- a printer with 1.80m length data cable. EUT(ES-524G+): *UTP port 1 --- via a 10m length RJ-45 cable to the PC LAN Port that located remotely. *UTP port 3~23 --- connect with a 3 m length RJ-45 cable that terminated with 200 ohm. * Fiber port 1 --- via a 5m length fiber cable to the fiber port of Fiber LAN Card installed in nearby PC. * Fiber port 2 --- not connected anything. * Power port --- via a 1.80m length power cable with a power adaptor to the power source. Report No.: R2015060373 Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778 Test Report ------------------------------------------------------------------------------- 5/13 List of support equipment Conducted (Radiated) test: PC Model No. Serial No. FCC ID Power type Power cord : : : : : : HP Pavilion t123d Doc Approved AC 100 –127 4.0A, 200-240 2.0A, 50 ~ 60Hz Non-shielded, 2.33m long, Plastic, No ferrite core Monitor Model No. Serial No. FCC ID Power type Power cord Data cable : : : : : : : HP pavilion mx70 P1283A THTBR00257 DOC Approved 100 ~ 240V AC 15A 50/60Hz Shielded, 1.83m long, No ferrite core Shielded, 1.46m (1.80m) long, with two ferrite cores (no ferrite core) Keyboard Model No. Serial No. FCC ID Power type Data cable : : : : : : HP SK-2501K MR80700789 GYUR38SK By PC Shielded, 1.73m long, with ferrite core Mouse Model No. Serial No. FCC ID Power type Power cord : : : : : : HP M-S34 LZB90714106 DZL211029 By PC Non-shielded, 1.88m long, No ferrite core USB Mouse Model No. Serial No. FCC ID Power type Power cord : : : : : : Logitech Wheel Mouse M-BJ-58 LN20901985 Doc Approved By PC Non-shielded, 1.88m long, No ferrite core DD281A-AB0 TW31720157 Report No.: R2015060373 Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778 Test Report ------------------------------------------------------------------------------- 6/13 Modem Model No. FCC ID Power type Power cord Data cable : : : : : : ACEEX XDM-9624 IFAXDM-9624 220VAC, 50Hz / 9VAC, 1A Non-shielded, 1.9m long, No ferrite cord RS232, Shielded, 1.2m long, No ferrite core RJ11C x 2, 7’ long non-shielded, No ferrite core Printer Model No. Serial No. FCC ID Power type Power cord Data cable : : : : : : : HP C2642A SG69A196GV B94C2642X 220 VAC, 50Hz Non-shielded, 2m long, no ferrite core Shielded, 1.84m (1.7m) long, no ferrite core USB Joystick Model No. Serial No. FCC ID Power type Power cable : : : : : : Rockfire QF-337uv 10600545 CE Approval Powered by PC Shielded, 1.8m!long, No ferrite bead data cable Fiber LAN Card Model No. Serial No. FCC ID Power type : : : : : RUBY TECH CORP. GE-1120xx N/A CE Approval Powered by PC Report No.: R2015060373 Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778 Test Report ------------------------------------------------------------------------------- 7/13 Chapter 2 Conducted Emission Test Test condition and setup: All the equipment is placed and setup according to the standard. The EUT is assembled on a wooden table that is 80 cm high, is placed 40 cm from the back-wall that is a vertical conducting plane. One LISN is for EUT, the other LISN is for support equipment. They are all placed on the conductive ground. The EUT’s LISN connect a line switch box for selecting L1 or L2, then connect to a preamplifier and spectrum for pretest. The spectrum measured from 150KHz to 30MHz. Conducted emission levels are detected at max. peak mode. But if the max. peak mode failed or over average limit, it will be measured by QP and average detection mode using the Receiver. While testing, there is the worst-emission plot printed at peak detection mode, and there are more than 6 highest emissions relative to limit recorded. The plot is kept as the original data, not included in test report. List of test Instrument : ! ! ! ! Calibration Date! Instrument Name! Model No.! Brand! Serial No.! Last time! Next time! Receiver LISN (EUT) LISN (Support E.) Line switch box FTB-1-6 Attenuator 20dB Attenuator Coaxial Cable Coaxial Cable 50ohm terminator 50ohm terminator 50ohm terminator 50ohm terminator SCHAFFNER EMCO EMCO TRC mini-circuits mini-circuits Jyebao Jyebao NARDA NARDA NARDA NARDA 012 9411-2284 9210-2007 98-04 9620 03 9620 13 CL-05 IF-01ca0069-036 PWR5W PWR5W PWR5W PWR5W 05/13/04 07/21/04 09/03/04 05/29/04 05/29/04 05/29/04 05/29/04 05/29/04 07/21/04 07/21/04 09/03/04 09/03/04 SCR3102 3825/2 3825/2 CB-01 15542 CAT-20 BNC3200B-0058 BNC31VB-0316 370BNM 370BNM 370BNM 370BNM 05/12/05 07/20/05 09/02/05 05/28/05 05/28/05 05/28/05 05/28/05 05/28/05 07/20/05 07/20/05 09/02/05 09/02/05 The level of confidence of 95% , the uncertainty of measurement of conducted emission is +3.1/-4.84 dB . Test Result : Pass (Appendix A) Report No.: R2015060373 Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778 Test Report ------------------------------------------------------------------------------- 8/13 Conducted Test Placement: (Photographs) Report No.: R2015060373 Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778 Test Report ------------------------------------------------------------------------------- 9/13 Chapter 3 Radiated emission test Test condition and setup : Prior to the final test (OATS test), the EUT is placed in a shielded enclosure, Pretest: and scan from 30MHz to 1GHz. This is done to ensure the radiation is exactly emitted from the EUT. Final test : Final radiation measurements is made on a 10 – meter, open-field test site. The EUT is placed on a nonconductive table, which is 0.8m height, the top surface is 1.0 x 1.5 meter. The placement is according to the standard. The M. E. whole range Antenna is used to measure frequency from 30 MHz to 1GHz. The final test is used the Receiver. Measure more than six top marked frequencies generated form pretest by computer step by step at each frequency. The EUT is rotated 360 degrees, and antenna is raised and lowered from 1 to 4 meters to find the maximum emission levels. The antenna is used with both horizontal and vertical polarization. Appropriated preamplifier that is made by TRC is used for improving sensitivity and precaution is taken to avoid overloading. The spectrum analyzer’s 6dB bandwidth is set to 120 K Hz, and the EUT is measured at quasi-peak mode. If the emission is close to the frequency band of ambient, the tester will recheck the data and the corrected data will be written in the test data sheet. If the emission is just within the ambient, the data from shielded room will be taken as the final data. List of test Instrument : ! ! ! ! Calibration Date! Instrument Name! Model No.! Brand! Serial No.! Last time!Next time Receiver Control Box Antenna Open test side Pre-amplifier Coaxial Cable (20meter) Coaxial Cable (50cm) Coaxial Cable (20cm) Coaxial Cable (55cm) Coaxial Cable (55cm) SCR3102 TWR95-4 CBL6141A SCHAFFNER TRC SCHAFFNER 012 C9001-2 4206 TRC-CB-2 RG-214/U BNC31VB-0316 BNC31VB-0318 BNC31VB-0316 BNC31VB-0316 TRC Jyebao Jyebao Jyebao Jyebao Jyebao CB-002 CL-002 CL-002 CL-007 CL-006 CL-005 05/13/04 N/A 05/27/04 05/29/04 05/29/04 05/29/04 05/29/04 05/29/04 05/29/04 05/29/04 05/12/05 N/A 05/26/05 05/28/05 05/28/05 05/28/05 05/28/05 05/28/05 05/28/05 05/28/05 The level of confidence of 95%, the uncertainty of measurement of radiated emission is +2.85/-2.77 dB. Test Result : Pass (Appendix B) Report No.: R2015060373 Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778 Test Report ------------------------------------------------------------------------------- 10/13 Radiated Test Placement: (Photographs) Report No.: R2015060373 Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778 Test Report ------------------------------------------------------------------------------- 11/13 Appendix A Conducted Emission Test Result: Test Mode: ES-524G+ Testing room : Temperature : 18 q C Humidity : 75 % RH Line 1 READING AMPLITUDE Frequency (KHz) LIMIT Peak Quasi-Peak Average Quasi-Peak Average (dBPV) (dBPV) (dBPV) (dBPV) (dBPV) Margin (dB) ˄ˉˌˁ˃˃ʳ ˇˉˁˌˌʳ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ˊˌˁ˃˃ ˉˉˁ˃˃ʳ ˀ˄ˌˁ˃˄ ˄ˌˉˁ˃˃ʳ ˅˅ˇˁ˃˃ʳ ˇˇˁ˄ˋʳ ˇˆˁˉ˄ʳ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ˊˌˁ˃˃ ˊˌˁ˃˃ ˉˉˁ˃˃ʳ ˉˉˁ˃˃ʳ ˀ˅˄ˁˋ˅ ˀ˅˅ˁˆˌ ˅ˈˉˁ˃˃ʳ ˇ˄ˁ˃ˈʳ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ˊˌˁ˃˃ ˉˉˁ˃˃ʳ ˀ˅ˇˁˌˈ ˆ˄˅ˁ˃˃ʳ ˇ˃˃ˁ˃˃ʳ ˇ˅ˋˁ˃˃ʳ ˆˊˁˉˉʳ ˆˋˁˈˋʳ ˆˌˁ˃ˌʳ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ˊˌˁ˃˃ ˊˌˁ˃˃ ˊˌˁ˃˃ ˉˉˁ˃˃ʳ ˉˉˁ˃˃ʳ ˉˉˁ˃˃ʳ ˀ˅ˋˁˆˇ ˀ˅ˊˁˇ˅ ˀ˅ˉˁˌ˄ ˄ˆ˃˅ˁ˃˃ʳ ˅ˉ˃˃ˁ˃˃ʳ ˇˋ˅˃ˁ˃˃ʳ ˇˊˁ˅ˋʳ ˆˈˁˋˈʳ ˇˊˁˉˋʳ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ˊˆˁ˃˃ ˊˆˁ˃˃ ˊˆˁ˃˃ ˉ˃ˁ˃˃ʳ ˉ˃ˁ˃˃ʳ ˉ˃ˁ˃˃ʳ ˀ˄˅ˁˊ˅ ˀ˅ˇˁ˄ˈ ˀ˄˅ˁˆ˅ Line 2 READING AMPLITUDE Frequency (KHz) LIMIT Peak Quasi-Peak Average Quasi-Peak Average (dBPV) (dBPV) (dBPV) (dBPV) (dBPV) Margin (dB) ˄ˊˆˁ˃˃ʳ ˇ˅ˁˉˇʳ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ˊˌˁ˃˃ ˉˉˁ˃˃ʳ ˀ˅ˆˁˆˉ ˅˃˄ˁ˃˃ʳ ˅ˈˉˁ˃˃ʳ ˉ˅˅ˁ˃˃ʳ ˆˋˁ˃ˇʳ ˆˇˁ˄˃ʳ ˆˇˁˋˆʳ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ˊˌˁ˃˃ ˊˌˁ˃˃ ˉˉˁ˃˃ʳ ˉˉˁ˃˃ʳ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ˊˆˁ˃˃ ˉ˃ˁ˃˃ʳ ˀ˅ˊˁˌˉ ˀˆ˄ˁˌ˃ ˀ˅ˈˁ˄ˊ ˄˅ˌ˅ˁ˃˃ʳ ˆˋˁˆˈʳ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ˊˆˁ˃˃ ˉ˃ˁ˃˃ʳ ˀ˅˄ˁˉˈ ˄ˉˆˌˁ˃˃ʳ ˆˉˁˇˉʳ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ˊˆˁ˃˃ ˉ˃ˁ˃˃ʳ ˀ˅ˆˁˈˇ ˅ˉˇ˃ˁ˃˃ʳ ˇ˅˃˃ˁ˃˃ʳ ˇ˅ˁ˅ˉʳ ˇˉˁ˄ˊʳ ˇˉˁˌ˄ʳ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ˊˆˁ˃˃ ˊˆˁ˃˃ ˊˆˁ˃˃ ˉ˃ˁ˃˃ʳ ˉ˃ˁ˃˃ʳ ˉ˃ˁ˃˃ʳ ˀ˄ˊˁˊˇ ˀ˄ˆˁˋˆ ˇˊˇ˃ˁ˃˃ʳ ʽʽʽˁʽʽ ʽʽʽˁʽʽ ʽʽʽˁʽʽ *The reading amplitudes are all under limit. Report No.: R2015060373 Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778 ˀ˄ˆˁ˃ˌ Test Report ------------------------------------------------------------------------------- 12/13 Appendix B Radiated Emission Test Result: Test Conditions: Testing site Frequency MHz : Temperature : Reading Ant. Amplitude Height dBPV/m m 15 q C Table degree Humidity : 89 % RH Correction Corrected Factors Amplitude dB dBPV/m Limit Margin dBPV/m dB (Horizontal) 125.0038 39.27 2.33 246 -6.55 32.72 40.00 -7.28 225.0251 37.74 3.96 83 -6.80 30.94 40.00 -9.06 275.0288 44.60 1.38 0 -4.30 40.30 47.00 -6.70 325.0351 47.58 2.26 0 -2.65 44.93 47.00 -2.07 375.0350 38.76 3.63 0 -0.80 37.96 47.00 -9.04 562.5088 34.14 1.19 56 4.40 38.54 47.00 -8.46 125.0138 36.31 1.19 0 -6.55 29.76 40.00 -10.24 175.0139 36.27 1.18 0 -5.90 30.37 40.00 -9.63 225.0218 40.67 1.06 168 -6.80 33.87 40.00 -6.13 275.0300 47.71 0.98 177 -4.30 43.41 47.00 -3.59 325.0301 46.66 1.00 0 -2.65 44.01 47.00 -2.99 875.0250 28.31 1.57 0 9.35 37.66 47.00 -9.34 *** (Vertical) *** Note: 1. Margin = Amplitude - limit, if margin is minus means under limit. 2. Corrected Amplitude = Reading Amplitude + Correction Factors 3. Correction factor = Antenna factor + ( Cable Loss - Amplitude gain ) (For example : 30MHz correction factor = 15.5 + (-15.26) = 0.24 dB/m) Report No.: R2015060373 Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778 Test Report ------------------------------------------------------------------------------- 13/13 Appendix C Photographs of EUT Report No.: R2015060373 Training Research Co., Ltd., TEL: 886-2-26461146, Fax: 886-2-26461778 ES-524G+ ES-524G+ ES-524G+ ES-524G+ ES-524G+ ES-524G+ ES-524G+ ES-524G+ ES-524G+ ES-524G+ ES516G+ ES516G+ ES516G+ ES516G+ ES516G+ ES516G+ ES516G+ ES516G+ ES516G+ ES516G+ LABEL Format: This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Trade Name: Edimax Model No.: ES-516G+, ES-524G+ Canadian ICES-003 LABEL Size: 40 X 15 mm LABEL Position: LABLE
Similar documents
Chapter 2 Conducted Emission Test
Chapter 9 Power Frequency Magnetic Field Immunity Test ............................ 21 EN 61000-4-8 Photo of Test Set-Up ...............................................................................
More information