Indola International Product Binder
Transcription
Indola International Product Binder
COMPANY PROFILE Indola International Philippines, Inc. is a leading distributor of ventilation products specializing in residential, commercial, industrial and agricultural applications; and consumer durable products such as bathroom accessories, water heater systems and hotel amenities. Established in 1997, Indola International addressed the problems of poor ventilations and unpleasant odors in the livestock and poultry environments as well as working areas by providing sustainable ventilation solutions through its heavy-duty exhaust fans. Diversifying its market, Indola International has expanded its product range to include bathroom ventilators and accessories and other consumer durable products to also serve the residential and commercial market. To ensure the quality of the products that it offers, Indola International represents only reputable global manufacturers who comply with internationally accepted product standards. The Indola International team is equipped with comprehensive product knowledge and application to consistently deliver a customized package to meet each customer’s requirements. Focused on providing utmost customer care, Indola International upholds quality in the products and services it delivers. VISION To be recognized as a leading reliable partner and supplier in the ventilation and consumer durable products industries in the Philippines. MISSION • To provide our valued customers with innovative solutions and top notch services. • To strengthen our reputation as a reliable source for high quality and competitively priced ventilation and consumer durable products. • To develop an extensive dealer network nationwide based on mutual cooperation and respect. FREE SERVICES OFFERED: • Site surveys and technical advice • Technical and product consultation • Installation for water heater systems (within Metro Manila) SOME NOTABLE PROJECTS: Century Park Hotel One Legaspi Place St. Peregrine Parish Plastimer Industrial Corp. Diamond Hotel Grand Quarter 2 Cardinal Santos Hospital Monterey Farms Manila Grand Opera Hotel Montgomery Place Ph. I - IV Megaworld Properties Jerby Foods Manila Hotel Newport City Federal Land Century Canning Manila Peninsula Presidio Bellini City Land Development SKK Steel Oriental Garden Hamilo Coast Italtel M.Y. San Biscuits The Pan Pacific Hotel DMCI Homes Globe Telecom Marulas Industrial Crown Tower Holy Spirit University EBC Fabricators Sta. Cruz Joy Enterprises The Grand Shang Tower International School Marikina Public Market Table of Contents Cassette Fans BROAN Deluxe Bathroom Fans BROAN Premium Bathroom Fan BROAN Kinglan Exhaust Fans BROAN Melan Exhaust Fan BROAN Exhaust Fan / Light Combination BROAN Recessed Exhaust Fan / Light Combination BROAN Room-to-Room Fan Utility Fan BROAN Losone Select Light Commercial Ventilators BROAN Multi-port Exhaust Fans MAXAIR G Series Exhaust Fans VENTS LD Series Kitchen & Bathroom Exhaust Fans 4 5 6 7 8 9 10 11 12 14 16 VORTICE CA Range In-line Centrifugal Extractor Fans VORTICE Lineo In-line Mixed Flow Extractor Fans VENTS VKM Series In-line Centrifugal Fans 18 20 24 INDOLA V Series Panel Fans (Metal Fan Blades w/ Metal Frame) INDOLA V Series Panel Fans (Stainless Steel Fan Blades w/ Metal Frame) INDOLA V Series Panel Fans (Stainless Steel Fan Blades w/ Polypropylene Frame) INDOLA Compact Panel Fans (Polypropylene Fan Blades w/ Polypropylene Frame) INDOLA Flanged Tube Series Compact Short Case Fans INDOLA EMI 130 Casing / Cone Fans INDOLA Recirculation Basket Fans INDOLA Low Pressure Nozzle System Misting Fans RIO Industrial Oscillating Fans RIO WV Series Industrial Exhaust Fans RIO WAB Series Tube Axial Flow Fans ROBOTECH Underground Parking Exhaust Jet Fans 28 30 32 36 38 40 42 44 46 48 50 51 INFINAIR ISQ Range In-line Square Centrifugal Fans INFINAIR CUS Range Centrifugal Utility Set INFINAIR ICC Range Low Noise Centrifugal Cabinet Fans INFINAIR RTC Range Rooftop Centrifugal Exhaust Fans INFINAIR IMX Range In-line Mixed-flow Exhaust / Supply Fans INFINAIR WEX / WSP Range Sidewall Axial Exhaust / Supply Fans 54 57 59 61 64 67 Mf-Net Mechanical Thermostats Mf-Net EW Series Electronic Variable Manual Speed Controllers Mf-Net Humidcon-s Humidity Regulator Mf-Net MBS Series Motor Protection Switches 72 75 76 78 VORTICE Premium Dry Range Manual & Automatic Hand Dryers VORTICE Optimal Dry Range Manual & Automatic Hand Dryers VORTICE Metal Dry Range Manual & Automatic Vandal-resistant Hand Dryers 80 81 82 In-Line Duct Fans Industrial Commercial Fans High Capacity Fans Fan Accessories and Controls Bathroom Accessories Cassette Fans EXHAUST FANS DELUXE BATHROOM FANS Versatile, High Quality Ventilators at Economy Prices. 688 / 671 EX FEATURES GrIlle • Mattewhitepolymericgrilleblendswellwithanydecor. • Torsionspringgrillemounting-notoolsrequired. Motor • Plug-in,permanentlylubricatedmotor. • PowerfulBroan-designedcentrifugalpolymericblowerwheel. • Snap in/out motor assembly for easy cleaning - no screws to drive or drop. hoUsInG • Compact,25-gaugegalvanizedsteelhousingfitseasilybetween ceiling joists or wall studs. • Double-strength steel mounting flanges with keyhole slots for DIMENSIONS fast installation. • Polymericductfittingwithtaperedsleeveforeasy,positiveduct connection. • Quietpolymericdamperpreventscoldbackdraftsandnometallic clatter. PERFORMANCE CURVE 688 / 671 EX STATIC PRESSURE (In. WG) 0.80 0.70 0.60 671 EX 0.50 0.40 688 0.30 EX 0.20 0.10 0.00 0 10 20 30 40 50 60 70 80 AIR FLOW RATE (CFM) U.L. Listed for use over bathtubs and showers when connectedtoaGFCI-protectedbranchcircuit. TECHNICAL SPECIFICATIONS 4 MODEL VOLTS AMPS SONES @ 0.1” Ps CFM (CMH) DUCT 688EX 220 0.7 3.0 50(85) 3” round 671EX 220 1.15 6.0 70 (119) 3” round BROAN Deluxe Bathroom Fans HVIcertifiedratingscomplywithtesting procedures prescribed by the Home Ventilating Institute and conducted at the Texas Engineering Experiment Station at Texas A & M University. Ratings are at 0.1 in. static pressure. Sones are a measure of loudness and are measured in HIV’s semi-reverberant sound test room. EXHAUST FANS PREMIUM BATHROOM FANS 676 EX Dependable, High Performance Bathroom Ventilation. FEATURES GrIlle • Whitepolymericgrillecomplementsvirtuallyanydecor. • Torsionspringgrillemounting-notoolsrequired. Motor • Plug-in,permanentlylubricatedmotor. • Centrifugalblowerwheeland4-polemotordeliverhighexhaust capacity at low levels. hoUsInG • Rugged steel housing finished with electrically-bonded epoxy paint. • Key-holedmountingbracketsoffersturdy,quickinstallation. • Polymeric duct connectors with tapered sleeves for easier, DIMENSIONS positive ducting and no metallic clatter. PERFORMANCE CURVE 676EX STATIC PRESSURE (In. WG) 0.50 0.40 0.30 0.20 0.10 0.00 0 20 40 60 80 100 120 AIR FLOW RATE (CFM) U.L. Listed for use over bathtubs and showers when connectedtoaGFCI-protectedbranchcircuit. TECHNICAL SPECIFICATIONS MODEL VOLTS AMPS SONES @ 0.1” Ps 676EX 220 1.30 4.0 CFM (CMH) DUCT 110 (187) 4”round BROAN Premium Bathroom Fan HVIcertifiedratingscomplywithtesting procedures prescribed by the Home Ventilating Institute and conducted at the Texas Engineering Experiment Station at Texas A & M University. Ratings are at 0.1 in. static pressure. Sones are a measure of loudness and are measured in HIV’s semi-reverberant sound test room. 5 EXHAUST FANS KINGLAN FAN FEATURES • Highefficiencycentrifugalfanblowerandoptimizedscrolldesign delivers29dB. • FleetlinewhitepolymericgrillebyAmericandesigners.Simplicity provides sophistication that will blend into any decor. • Fully enclosed compact metal galvanized rustproof housing design resists water and corrosion against salt spray test. Provides better resistance against fire for home safety. • Energysavingandlownoise,permanentlylubricatedballbearing motor. Designed for low-temperature rise, the motor is safe and engineered for continuous operation. • Built-in damper prevents air backdrafts or water backflow for better ventilation performance and energy efficiency. • Easy installation and maintenance to all kinds of installation environments. FA-A010PH / FA-A013PH FA-A016PH / FA-C020PH NOTE: 1. Air flow value is Broan laboratory test results with +/-10% tolerance range. 2. ThenoisevalueisA-weightedsoundpressurelevel,itisBroan DIMENSIONS laboratorytestresultswith+2-5tolerancerange. 3. The parameters below may be changed without prior notice. Pressure (Pa) PERFORMANCE CURVE Air Flow (m3/h) FA-A010 FA-A013 FA-A016 Φ 100 Duct Damping Curve FA-A fans FA-C fans TECHNICAL SPECIFICATIONS 6 WATTS NOISE (dB) CFM (CMH) STATIC PRESSURE (Pa) WT. (kg.) DUCT SIZE (mm) CUT SIZE (mm) 0.09 20 29 58(100) 95 2.2 100 ø 210x210 220/60 0.10 22 35 76 (130) 140 2.2 100 ø 210x210 FA-A016PH 220/60 0.12 26 39 94(160) 190 2.2 100 ø 210x210 FA-C020PH 220/60 0.18 39.6 42 117(200) 280 100 ø 210x210 MODEL VOLTS / Hz AMPS FA-A010PH 220/60 FA-A013PH BROAN Kinglan Exhaust Fans EXHAUST FAN MELAN FAN FC-A040PH FEATURES • Classic metal grille processed with high-tech white coating to satisfy your high end decoration. Simplicity provides sophistication that will blend into any decor in your home. • Fully enclosed compact metal galvanized rustproof housing design resists water and corrosion against salt spray test. Provides better resistance against fire for home safety. • Energysavingandlownoise,permanentlylubricatedballbearing motor. Designed for low-temperature rise, the motor is safe and engineered for continuous operation. • Built-in damper prevents air backdrafts or water backflow for better ventilation performance and energy efficiency. • Easy installation and maintenance to all kinds of installation environments. NOTE: 1. Air flow value is Broan laboratory test results with +/-10% tolerance range. 2. ThenoisevalueisA-weightedsoundpressurelevel,itisBroan DIMENSIONS laboratorytestresultswith+2-5tolerancerange. 3. The parameters below may be changed without prior notice. Pressure (Pa) PERFORMANCE CURVE Air Flow (m3/h) FC-A040 Φ 150 Duct Damping Curve TECHNICAL SPECIFICATIONS MODEL VOLTS / Hz AMPS FC-A040PH 220/60 0.23 NOISE WATTS (dB) 51 45 CFM (CMH) STATIC PRESSURE (Pa) WT. (kg.) DUCT SIZE (mm) CUT SIZE (mm) 237(400) 190 5.6 150ø 287x265 BROAN Melan Exhaust Fan 7 EXHAUST FAN / LIGHT FAN / LIGHT COMBINATION LA-C012PH FEATURES • Classic white polymeric grilles, streamline design eliminates squaringw/bathroomwallsandcomplementvirtuallyanydecor. • Anidealcombinationoffanandlightthatoperatesindependently or simultaneously. • Fully enclosed compact metal galvanized rustproof housing design resists water and corrosion against salt spray test. Provides better resistance against fire for home safety. • Energysavingandlownoise,permanentlylubricatedballbearing motor. Designed for low-temperature rise, the motor is safe and engineered for continuous operation. • Built-in damper prevents air backdrafts or water backflow for better ventilation performance and energy efficiency. • Easy installation and maintenance to all kinds of installation environments. NOTE: 1. Air flow value is Broan laboratory test results with +/-10% tolerance range. DIMENSIONS 2. ThenoisevalueisA-weightedsoundpressurelevel,itisBroan laboratorytestresultswith+2-5tolerancerange. 3. The parameters below may be changed without prior notice. Pressure (Pa) PERFORMANCE CURVE Air Flow (m3/h) Φ 100 Duct Damping Curve LA-C012 TECHNICAL SPECIFICATIONS 8 MODEL VOLTS / Hz AMPS LA-C012PH 220/60 0.08 WATTS NOISE (dB) CFM (CMH) STATIC PRESSURE (Pa) WT. (kg.) DUCT SIZE (mm) CUT SIZE (mm) 18 43 70(120) 110 3.0 100 ø 222x216 BROAN Exhaust Fan / Light Combination EXHAUST FAN / LIGHT RECESSED FAN / LIGHT COMBINATION RA-A012PH FEATURES • Beautifully designed recessed fan/lights disappear into the ceiling with other recessed lights. Trim matched to designs of major recessed light manufacturers. • Anidealcombinationoffanandlightthatoperatesindependently or simultaneously. • Highefficiencycentrifugalfanblowerandoptimizedscrolldesign delivers120CMHat35dB. • Fully enclosed compact metal galvanized rustproof housing design resists water and corrosion against salt spray test. Provides better resistance against fire for home safety. • Energysavingandlownoise,permanentlylubricatedballbearing motor. Designed for low-temperature rise, the motor is safe and engineered for continuous operation. • Built-in damper prevents air backdrafts or water backflow for better ventilation performance and energy efficiency. • Easy installation and maintenance to all kinds of installation environments. NOTE: DIMENSIONS 1. Air flow value is Broan laboratory test results with +/-10% tolerance range. 2. ThenoisevalueisA-weightedsoundpressurelevel,itisBroan laboratorytestresultswith+2-5tolerancerange. 3. The parameters below may be changed without prior notice. 01 310 mm 185 mm 2 m m PERFORMANCE CURVE mm Pressure (Pa) ø 160 ø 169 mm Air Flow (m3/h) Φ 100 Duct Damping Curve RA-A012 TECHNICAL SPECIFICATIONS MODEL VOLTS / Hz AMPS RA-A012PH 220/60 0.10 WATTS NOISE (dB) CFM (CMH) STATIC PRESSURE (Pa) WT. (kg.) DUCT SIZE (mm) 22 35 70(120) 150 3.4 100 ø BROAN Recessed Exhaust Fan / Light Combination 9 UTILITY FAN ROOM-TO -ROOM FAN 511 EX Powerful Solutions for Problem Rooms. Room-to-room ventilators provide quick solutions where more ventilation is needed - without installing new duct work. Easily installs in interior walls to move heated or cooled air from one room to another. Spreads heat from fireplaces, cool air conditioners to adjoining rooms. FEATURES GrIlle • Paintablewhitepolymericgrillestomatchanydecor. Motor • Permanentlylubricated,thermallyprotectedplug-inmotor. • Speciallydesignedpolymericbladeswillnotdistort. • Motorassemblyfeaturesfast,easy“twist-lock”installation. • Built-invariablespeedcontrol. hoUsInG • Requires11⅝”squareholethroughbothinteriorwalls. • Housing can be fastened to walls in several ways - allows flexibility; to meet almost any mounting situation. • Adjustablehousingfitswallsfrom3”to5½”thick. • Ruggedsteelhousing. • Housing finished with rugged black electrically-bonded epoxy paint. DIMENSIONS PERFORMANCE CURVE 511EX STATIC PRESSURE (In. WG) 0.15 0.12 0.09 0.06 0.03 0.00 0 50 100 150 200 250 AIR FLOW RATE (CFM) TECHNICAL SPECIFICATIONS 10 MODEL VOLTS AMPS SONES @ 0.1” Ps CFM (CMH) 511EX 220 1.5 3.5 180 (306) BROAN Room-to-Room Fan Utility Fan HVIcertifiedratingscomplywithtesting procedures prescribed by the Home Ventilating Institute and conducted at the Texas Engineering Experiment Station at Texas A & M University. Ratings are at 0.1 in. static pressure. Sones are a measure of loudness and are measured in HIV’s semi-reverberant sound test room. LIGHT COMMERCIAL VENTILATORS LOSONE SELECT L-100 / 150 EX Incredibly Reliable. Unbelievably Quiet. Broanhighcapacityfansareanexceptionallyquietsolutiontocontinuous ventilation.Withtheirheavy-dutymotors,highcapacityfansareanideal solution conference rooms, commercial kitchens and spaces that require ongoing ventilation. Low-vibration and low-profile, they work quietly without getting noticed. FEATURES GrIlle • Attractive low profile white polymeric grille blends with any decor. Motor • Low RPM motor mounted on resilient mounts for quiet, vibration-free operation. • Permanently lubricated motor designed for continuous operation. • Single, impact-resistant balanced centrifugal blower wheel for DIMENSIONS extremely low sound levels. hoUsInG • Heavy20gaugegalvanizedsteelhousing. • 6”roundductconnector. • ½”acousticinsulationinsidetoreducesoundlevels. • 8-wayadjustablemountingbracketspermitinstallationflexibility. • Quiet,automaticbackdraftdamperbuiltintotheductconnector. PERFORMANCE CURVE L100, L150 Series (Ceiling Mount) 1.00 L1 50 er S 0.80 s 0.70 ie L1 00 S er 0.60 ies STATIC PRESSURE (In. WG) 0.90 0.50 0.40 0.30 0.20 0.10 0.00 0 20 40 60 80 100 120 140 160 180 200 AIR FLOW RATE (CFM) Performance ratings include the effects of inlet grille and backdraft d a m p e r i n t h e a i r s t r e a m. T h e sound ratings shown are loudness valuesinfansonesat5’(1.5m)ina hemispherical free field calculated per AMCA Std. 301. Values shown areforInstallationTypeB:freeinlet fan sone levels. Performance shown isforInstallationB:Freeinlet,Ducted outlet. U.L. Listed for use over bathtubs and showers when connectedtoaGFCI-protectedbranchcircuit. TECHNICAL SPECIFICATIONS SONES MODEL VOLTS AMPS @ 0.2” TSP CFM (CMH) DUCT L100EX 220 0.5 0.5 100 (170) 6” round L150EX 220 0.7 1.3 150(255) 6” round SonesandCFMlistedforceilingmountmodelsare forhorizontalductingat.125”staticpressure. BROAN Losone Select Light Commercial Ventilators 11 MULTI-PORT EXHAUST FAN MULTI-PORT IN-LINE VENTILATOR MP100 EX FEATURES BloWer • High pressure, centrifugal blower accomodates many ducting configurations. • Motorsdesignedforcontinuousoperation. • Permanentlylubricatedmotorassuresworry-freeoperation. • PermanentSplitCapacitor(PSC)motorusedforquietoperation and low power consumption. • Plug-inmotorratedat220/240VAC,50/60Hzoperation. hoUsInG • Rugged20gaugesteelhousingfinishedwithelectrically-bonded epoxy paint. • Maybeinstalledinvirtuallyanyorientation-ceiling,wallorfloor. • In-lineinstallationassuresquietoperation. • Easilyremovablepanelpermitsquickaccestoblowerforcleaning and servicing without disturbing the ductwork. DIMENSIONS • Four10.16cm.(4”)roundinletsandasingle15.24cm.(6”)round outlet for easy ducting connections. 26.67 cm • Allwiringandductworkcanbeconnectedfromtheoutsideofthe (10.5”) housing - no need to remove access panel or blower. 27.94 cm (11”) PERFORMANCE CURVE 1.10 1.00 24.13 cm (9.5”) Static Pressure (IN. WG.) 0.90 0.80 0.70 0.60 31.75 cm (12.5”) 0.50 20.32 cm (8”) 0.40 0.30 0.20 0.10 0.00 Air Flow Rate (CFM) TECHNICAL SPECIFICATIONS 12 MODEL VOLTS / Hz AMPS WATTS MP100 EX 220/60 0.30 90 RPM CFM (CMH) STATIC PRESSURE (Pa) SHIPPING WT. (kg.) DUCT SIZE 2590 120(204) 120CFM@0Pa 7.26 6” round BROAN Multi-port Exhaust Fans MULTI-PORT EXHAUST FAN MULTI-PORT DUCT VENTILATOR The ventilator uses single inlet centrifugal ventilator, it has three inlets and one outlet which makes it a highly flexible duct ventilator suitable for many applications. MPU-A125-3X100 FEATURES • MPUissuitableforapplicationswherethereisnorequirements for condensation separation. • Theventilatorhousingismanufacturedfromcorrosionresistant high tensile pre-galvanized steel with an insulated bottom and side plate. • Forward curved impeller, external rotor motor and auto-reset automatic thermal overload protection. • Longlifetimeandeasyinstallation. • Veryeasytocleanwithitsswing-outdesign. DIMENSIONS Ø 125 364 254 PERFORMANCE CURVE Pressure (Pa) 600 Ø 100 500 Ø 100 400 Ø 100 300 200 100 0 182 0 100 200 300 400 500 600 Air Flow Rate (m3/h) 272 365 TECHNICAL SPECIFICATIONS MODEL VOLTS / Hz AMPS MPU-A125-3X100 220/60 0.58 WATTS CFM (CMH) STATIC PRESSURE (Pa) NOISE (dB) WT. (kg.) DUCT SIZE (mm) 128 224 (380) 400 41 4.7 Inlet 100 ø Outlet125ø 13 EXHAUST FANS G SERIES APPLICATIONS • Residential Homes • Kitchens • Bathrooms • Restaurants G690 FEATURES • High-speed for a large airflow • Dual speed option • Efficiently removes moisture, carbon dioxide and odors during the quiet operations • Contemporarydesignofgrilles • Built-indampertopreventairbackdraft • Metal housing with rust proof paint • Long-life motor • Easy installation and maintenance • Colorofgrille:white CERTIFICATIONS PERFORMANCE CURVE Static Pressure Watts DIMENSIONS Static Pressure Watts TECHNICAL SPECIFICATIONS 14 MODEL VOLTS (@ 60 Hz.) RATED POWER (Watts) NOISE (Sones) AIR VOLUME (CFM) DUCT DIA. (mm.) GRILL SIZE (mm.) MOUNTING SIZE (mm.) G690 220 25/20 1.5/0.5 90/60 100(4in.) 260x260 210x210 MAXAIR G Series Exhaust Fans EXHAUST FANS G SERIES APPLICATIONS • Residential Homes • Kitchens • Bathrooms • Restaurants G6120 FEATURES • High-speed for a large airflow • Dual speed option • Efficiently removes moisture, carbon dioxide and odors during the quiet operations • Contemporarydesignofgrilles • Built-indampertopreventairbackdraft • Metal housing with rust proof paint • Long-life motor • Easy installation and maintenance • Colorofgrille:white CERTIFICATIONS PERFORMANCE CURVE Static Pressure Watts DIMENSIONS Static Pressure Watts TECHNICAL SPECIFICATIONS MODEL VOLTS (@ 60 Hz.) RATED POWER (Watts) NOISE (Sones) AIR VOLUME (CFM) DUCT DIA. (mm.) GRILL SIZE (mm.) MOUNTING SIZE (mm.) G6120 220 40/35 1.5/0.9 120/90 100(4in.) 300 x 300 250x250 15 KITCHEN & BATHROOM FANS LD SERIES 100 / 150 LD Axial extract LD fans are the perfect ventilation solution for the modern kitchens, bathrooms or toilets. Flat square shaped front cover will match even the most refined interior. No additional mounting boxes or special niches are needed, just connect the fan to the air duct and fasten it with screws. FEATURES • MadeofhighqualityABSplastic. • 7-bladessilentimpeller. • Suitableforoperationinambienttemperatures40°Fto+100°F. • Integrated component design allows all parts to be dismantled for cleaning without the use of special tools. CERTIFICATIONS DIMENSIONS Pressure (Pa) PERFORMANCE CURVE 100 LD 150 LD MODEL a b c D e 100LD 150 108 126 100 30 150LD 205 165 153 150 36 Extract capacity (CMH) TECHNICAL SPECIFICATIONS 16 STATIC NOISE PRESSURE dB(A) @ (Pa) 3m MODEL VOLTS @ 60 Hz WATTS AMPS RPM CFM (CMH) LD 220-240 14 0.085 2300 52(88) 33 33 0.60 LD 220-240 24 0.130 2400 156(265) 78 37 0.96 LD TUBO 220-240 16 0.100 2300 68(115) 38 36 0.68 LD TUBO 220-240 30 0.130 2400 182(310) 87 39 1.10 VENTS LD Series Kitchen & Bathroom Exhaust Fans WT. (kg.) In-Line Duct Fans IN-LINE CENTRIFUGAL EXTRACTOR FANS CA R ANGE FEATURES CA 150 Q MD CA 200 / 315 • Ball-bearing-mountedmotorwithexternalrotormotorandhandoperated resettable thermal cut out. • IMQ information label certifies third party product data and performance. • ComplieswiththeCEIEN60335-2-80standard. • Turbine fan balanced directly on the motor. • Motor-holder made of steel and paint-finished with furnacehammered epoxy powder for perfect weather protection. • Galvanized steel motor mounting brackets and air flow deflectors. • Twospeeds(CA150QMD) • Speed can be adjusted using an optional controller. • ClassIIinsulation(CA150QMD) • Supplied with mounting brackets for easy installation; 1 pc. for CA150QMDand2pcs.forCA150andCA315. CA 150 Q MD DIMENSIONS (mm.) LONG LIFE: 30,000 hours ØE A ØD CA 200 CA 315 C F F B CA150 Q MD G A C CA D E B Code A B C ØD ØE F 30 G CA 150 Q MD 16152 30 239 295 147 255 CA 200 16040 25 270 390 197 340 25 386 CA 315 16061 40 308 450 312 400 44 416 CA 200 / 315 TECHNICAL SPECIFICATIONS Product CA 150 Q MD V 230 Hz 60 irflow mh irflow ls Pressure mmH2O Pressure Pa min ma min ma min ma min ma min ma min ma 60 85 0.30 0.40 300 500 83 139 21 35 206 343 PM min ma Lp dB m min ma 1430 2350 34.7 48.1 pprov. Ma Ins. Temp. Class C 44 cl.II 50 CA 200 220-240 50/60 180 0.75 950 263.9 55 539 2710 64 44 cl.I 50 CA 315 220-240 50/60 260 1.3 1700 486.1 75 735 2550 67 44 cl.I 60 * Sound level measured at 3m from inlet in free air condition with product ducted only in outlet according to EN ISO 3741:2009. 18 IP VORTICE CA Range In-line Centrifugal Extractor Fans F DIMENSIONS (mm.) E D 18 B 5 10 10 R 2,5 7,2 A C Galvanised sheet-metal bracket (CA 150 Q MD) - 1 piece 285 260 32 Galvanised sheet-metal brackets (CA 200 / 315) - 2 pieces 130 PERFORMANCE CURVE max min FREQUENCY BANDS IN OCTAVES AND SOUND OUTPUT (Maximum Speed) CA Code CA 150 Q MD 16152 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 55.9 68.4 66.1 62.6 62.6 56.9 48.9 CA 200 16040 48.5 57.5 68.0 71.0 72.3 71.0 67.1 64.2 CA 315 16060 54.0 60.0 67.0 72.4 71.2 70.5 67.5 69.1 ThemeasurementsofthesoundpowerhavebeencarriedoutaccordingtointernationalstandardISO3741:2009. 19 IN-LINE MIXED FLOW EXTRACTOR FANS VORTICE® LINEO FEATURES For duct mounting. Safety and acoustic performances certified. • Lineo series extractors have certified air flow, pressure (to UNI 10531:1995, corresponding to ISO 5801) and noise levels (UNI EN ISO 3741). Certification of these parameters guarantees that our products will always meet the your requirements and expectations. • Compact overall dimensions. The products have a very small overall size, making them ideal for installation in cramped areas. Slim yet powerful, the overall diameter is only slightly larger than the ventilation duct it connects to. • Protection rating IPX4. The products are protected against jets of water from all directions, making them ideal for installation in humid and wet areas. • Two speeds. All models feature two speed operation, including timer equipped models. • Adjustable Timer. Vortice Lineo products are also available with an adjustable, from 3 to 20 minutes, overrun timer. • Double insulation. No earth is required. • Self-extinguishing V0 plastic. All models are constructed in V0 grade plastic to guarantee the highest available selfextinguishing rating as well as excellent mechanical strength. • Eco-friendly. All Lineo components can be easily disassembled and are designed to be recyclable and to comply with the requirements of Article 4 of the “WEEE” directive (waste electrical and electronic equipment). The products are carefully designed to provide an extended life cycle and to provide a low environmental impact both in manufacture and use. • Speed adjustable. All models can be speed adjusted with the optionally available controllers. 20 • Intelligent. Vortice Lineo products are capable of advanced functionality in combination with optional sensor units for monitoring humidity, detecting persons, ambient temperature, pollutant levels and air quality. • The entire Lineo range is fitted with ball bearing motors for a minimum 30,000 hours operation without mechanical malfunction. • Safe. Safety, power rating, protection rating (IPX4 to EN 60529) and insulation are certified by the IMQ (Quality Mark Institute), the Italian national certifying agency. • Optimum energy efficiency. Our research programmes have enabled us to obtain the best possible ratio between running costs and performance. • Overload protection. The top of the range models feature a manual reset limiter on the motor. Other models are equipped with thermal cut-out switch. • Compliance to standards. The entire range of Vortice Lineo extractors has been constructed tocomplywithCEIEN60335-280-1997. Performance conforms toUNI10531(CategoryD).They beartheCEMarkforcompliance with the Low Voltage Directive (LVD) and Electromagnetic CompatibilityDirective(EMC). Lineo 200 / 250 / 315 LONG LIFE: 30,000 hours Quick, easy installation. The mounting brackets supplied with the unit make installation quick and easy. The junction box can be rotated to fit the mounting point for even simpler installation. Mounting bolts included. Simple maintenance. Lineo products are equipped with a unique double-lever closure which allows the fan unit to be removed in just a few seconds without affecting the installation as a whole. Instructions clearly show that screws should be reinstalled on installation. Refitting the unit is just as quick and easy. VORTICE Lineo In-line Mixed Flow Extractor Fans DIMENSIONS (mm.) Model Lineo 200 V0 Lineo 250 V0 Lineo 315 V0 Code 17007 17009 17010 A 300 385 448 ØB 196 247 312 C 125.5 152.5 188.5 D 260.5 317 392.5 E 234.5 300 361.5 F 140 176.5 220.5 L 235 292 359 Gr. 3700 7000 11300 TYPICAL INSTALLATIONS As a single unit at the duct inlet As a single unit within the duct As a single unit at the duct outlet In series (doubles the pressure) In parallel (doubles the air flow) In parallel for rectangular ducts Vortice Lineo extractors can be mounted in a wide range of options - at the beginning, middle or end of the air duct and horizontally, vertically, against walls, ceilings, false ceilings or any flat surface. One of the main features of the new Vortice Lineo range, in addition to ease of installation, is the fact that the fan unit can be removed from situ, for inspection and maintenance, in just a few seconds. Vortice Lineo units can be fitted to standard round section pipes and to rectangular air ducts (using unique special mounting accessories). The integrated IPX4 rated electrical junction box has an airtight cover. The product is supplied complete with a bag of accessories including anchor bolts and plugs, cable clamps and grommets. 21 SAFETY GUARANTEED AND CERTIFIED The IMQ mark certifies that the product is manufactured in compliance with the provisions of establishedsafetystandardsEN60335-1andEN60335-2-80.theLowVoltageDirective(LVD)andthe Electromagnetic Compatibility Directive (EMC). IMQ further guarantees regular, constant production quality monitoring. TheIMQmarkisequivalenttothefollowingEuropeanmarks: TECHNICAL SPECIFICATIONS PERFORMANCE AND SILENCE GUARANTEED AND CERTIFIED BY IMQ PERFORMANCE IMQPERFORMANCEisanindependentqualitymarkwhichcertifies,tointernationalstandards*,the performance (flow rate and pressure) and noise levels of the product. TECHNICAL SPECIFICATIONS 22 PERFORMANCE CURVE Pa 750 mmH 2O 75 32 600 60 24 450 45 400 mmH 2O 40 40 320 30 240 500 mmH 2O 50 400 300 Lineo 200 V0 - T V0 Pa Lineo 200 V0 - T V0 200 20 160 16 300 30 100 10 80 8 150 15 0 0 0 m 3/h l/s 0 0 250 500 750 1000 69 139 208 278 Single Pa qv 0 0 1250 m 3/h 0 500 1000 1500 2000 2500 347 l/s 0 140 280 420 560 700 In parallel Lineo 250 V0 mmH 2O Pa 75 600 60 600 60 480 450 45 360 m 3/h 0 l/s Lineo 250 V0 Pa 100 48 800 80 36 600 60 30 240 24 400 40 150 15 120 12 200 20 600 900 1200 1500 l/s 83 166 250 333 416 0 Single Pa qv mmH 2O 1000 100 800 600 0 0 m 3/h 0 600 1200 l/s 0 165 335 In parallel Pa Lineo 315 V0 150 80 1200 120 60 900 90 1800 500 2400 3000 670 835 400 40 600 60 200 20 300 30 0 0 0 500 1000 1500 2000 2500 l/s 0 139 278 416 555 694 Single qv 250 500 750 1000 1250 0 70 140 210 280 350 qv Lineo 250 V0 APPLICATION: Single - In parallel In series In series 0 Lineo 315 V0 350 700 97 194 qv 1050 1400 1750 292 389 486 LINEO 315 V0 (cod. 17010) SPEED max min APPLICATION: Single - In series 0 0 0 m 3/h l/s 0 0 0 m 3/h l/s LINEO 250 V0 (cod. 17009) SPEED max min In series p pt qv mmH 2O 1500 m 3/h 0 p 300 300 APPLICATION: Single - In parallel In series mmH 2O 1000 LINEO 200 V0 (cod. 17006) LINEO 200 T V0 (cod. 17026) SPEED max min In series p pt qv mmH 2O 750 0 0 m 3/h 0 Lineo 200 V0 - T V0 p p pt Pa 0 500 1000 1500 2000 2500 140 280 420 560 700 qv 23 IN-LINE CENTRIFUGAL FANS VKM SERIES FEATURES • Steel fan casing with zinc phosphate treatment and polymeric coating. • Equippedwitha1-phaseexternalrotormotor,ballbearingsand automatic reset thermal overload protection. • Speedcanbeadjustedusinganoptionalcontroller. • Wall or ceiling mounting at any angle with fastening brackets supplied with the unit. • IPX4protectionrating. • VKM...Qforlow-noisedesignoption VKM 150 / 200 / 250 / 400 VKM 355 Q VKM 150 / 200 / 250 VKM 355 / 400 DIMENSIONS (mm.) MODEL 24 ØD ØD1 B B1 L L1 L2 L3 VKM 150 149 304 349 309 220 25 25 30 VKM 200 198 344 390 350 240 25 29 40 VKM 250 248 344 390 350 249 25 31 40 VKM 355 Q 353 460 522 522 506 60 60 70 VKM 400 398 570 663 634 570 60 60 70 VENTS VKM Series In-line Centrifugal Fans TECHNICAL SPECIFICATIONS CFM CMH NOISE dB m 2705 326 555 47 -22+55 5.4 0.67 2375 559 950 48 -25+50 6.6 194 0.85 2790 771 1,310 52 -25+50 7.3 230 233 1.06 1375 1,300 2,210 58 -25+45 12.8 230 460 2.23 1370 1,795 3,050 61 -40+80 20.0 MODEL VOLTS Hz TTS MPS PM VKM 150 230 98 0.43 VKM 200 230 154 VKM 250 230 VKM 355 Q VKM 400 I VOLUME M. OPETING TEMP. C T. kg. Pressure, Pressure, P [Pa] P [Pa] PERFORMANCE CURVE Air capacity, [m 3/h] Pressure, Pressure, P [Pa] P [Pa] Air capacity, [m 3/h] Air capacity, [m 3/h] Air capacity, [m 3/h] 25 26 Industrial Commercial Fans PROPELLER FANS V SERIES PANEL FANS METAL FAN BLADES WITH METAL FRAME VWZ 200 / V4S2561 DESCRIPTION The fans consist of a motor and impeller fixed to a square fan casing (or wall-plate) by support arms and screws. The motor and impeller may be removed easily while leaving the wall-plate in place. The fans have five blades pressed from a single piece of sheet steel. Impeller, motor casing and wall plate have a scratch and chemical resistant epoxy coating. Dust accumulation is prevented by the smooth design of the motor casing. The special construction of the motor-impeller combination in the wall plate ensures a highly stable assembly and exact centering. The motor has an integral electrical supply cable. TECHNICAL DETAILS electrIcal sPecIFIcatIons VWZ200:220V/60Hz.,1Phase V4S2561:220V/60Hz.,1Phase APPLICATIONS Motors The fans are powered by a direct drive electrical motor with fully enclosed ball bearings. The motors have insulationClassBwindingsandareprotectedtoIP44 standard. The fans are aerodynamically designed to give maximum air volume and pressure with minimum electrical consumption. They can be used as extractors or inlet fans on their own, or fitted in or on ducts and other types of equipment. aMBIent teMPeratUre Suitableforuseinambienttemperaturebetween-20°C and+70°C. MaIntenance The fans require only cleaning. The motor bearings require no lubrication or maintenance. TECHNICAL SPECIFICATIONS 28 MODEL BLADE Ø mm. (in.) RPM WATTS AMP VWZ 200 200(8”) 1,570 38 V4S2561 250(10”) 1,660 40 AIR VOLUME CMH CFM 0.22 550 323 0.20 1,100 647 INDOLA V Series Panel Fans (Metal Fan Blades w/ Metal Frame) DIMENSIONS (mm.) E F A B C MODEL A B C E F VWZ 200 230 280 63 23 200 V4S2561 280 330 68 23 250 PERFORMANCE CURVE NOTE: AircapacityvaluesaredeterminedbytheuseoftheDIN24163/NEN1048-IItestingmethod.Thevaluesobtainedfollow closelythosewhentestingaccordingtoBS848part1.Theaircapacityvaluesaremeasuredovertheairflowtestrig.Air capacity values given in cubic meters per hour (m3h).StaticpressurevaluesaregiveninPascal:Pst(Pa). 29 PROPELLER FANS V SERIES PANEL FANS STAINLESS STEEL FAN BLADES METAL FRAME V4S3062 / V4S4061 V4S5061 / VDBZ 500 V8S9261 / V8T9261 WITH DESCRIPTION The fans are equipped with stainless steel blades. The motor and impeller may be removed without removing the wall plate. The extremely robust construction means that standard models can be used in harsh environments. Epoxy coating is provided as standard. Therangealsoincludes500mmmodel(VDBZ)witha six-bladed impeller for increased volume and pressure development. The unit has three motor support arms with four fixings. TECHNICAL DETAILS Motors The fans are powered by a direct drive electrical motor with maintenance-free fully enclosed ball bearings. AllmodelsconformtoClassFinsulation(resistantto temperaturesupto155°C)andareprotectedtoIP55. The motors have integral thermal protection: a ‘thermal cut-out’ protects the motor on the basis of the maximum permissible winding temperature so the motor is protected throughout the entire control range. The external contacts of the thermal cut-out could be used with a special motor protection switch. TECHNICAL SPECIFICATIONS 30 MODEL BLADE Ø mm. (in.) NO. OF BLADES V4S3062 300(12”) 4 V4S4061 400(16”) 4 V4S5061 500(20”) 4 VDBZ 500 500(20”) 6 V8S9261 920(36”) 3 V8T9261 920(36”) 3 VOLT (Phase) 240 (1 phase) 220-240/ 380-415 (1 phase) 240 (1 phase) 240/420 (3 phase) RPM WATTS AMP 1,600 120 1,600 AIR VOLUME CMH CFM 0.5 2,250 1,325 290 1.6 5,300 3,120 1,600 300 2.3 7,450 4,385 1,600 650 2.6 11,260 6,627 800 710 4.2 19,100 11,240 800 570 3.4/2.0 19,100 11,240 INDOLA V Series Panel Fans (Stainless Steel Fan Blades w/ Metal Frame) DIMENSIONS (mm.) A F B A B E D C MODEL A B C D E F V4S3062 350 395 292 186 106 330 V4S4061 444 495 292 186 106 430 V4S5061 565 635 292 176 116 535 VDBZ 500 565 635 360 232 133 500 V8S9261 1010 1070 403 215 188 973 V8T9261 1010 1070 403 215 188 973 PERFORMANCE CURVE 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 120 1 2 3 4 5 6 90 6 80 5 60 40 1 2 6 = = = = = = V4 S30 62 V4 S 4 0 61 V4 S5 0 61 V DB Z 5 0 0 V8S9261 V8T 9261 3 4 20 0 2000 4000 6000 8000 10000 12000 14000 16000 18000 NOTE: AircapacityvaluesaredeterminedbytheuseoftheDIN24163/NEN1048-IItestingmethod.Thevaluesobtainedfollow closelythosewhentestingaccordingtoBS848part1.Theaircapacityvaluesaremeasuredovertheairflowtestrig.Air capacity values given in cubic meters per hour (m3h).StaticpressurevaluesaregiveninPascal:Pst(Pa). 31 PROPELLER FANS V SERIES PANEL FANS STAINLESS STEEL FAN BLADES POLYPROPYLENE FRAME V4S3060 / V4S4060 V4S5060 / V6S7160 V4T5060 / V6T6360 / V6T7160 WITH DESCRIPTION A compact and modern looking fan with polypropylene frame, stainless steel blades, and aluminum parts for thehousingandsupport.Thebladescomein4and6 variations which are directly driven by an inside-rotor motor with fully enclosed greased for life ball bearings for continuous running. Steel parts of rotor and stator are multiwax coated for protection against corrosion. Motor windings are provided with three insulation films for maximum protection against humidity. AllmodelsconformtoIP55ratingandClassFinsulation (resistanttotemperaturesupto155°C).Allmaterials can be recycled. TECHNICAL SPECIFICATIONS 32 MODEL BLADE Ø mm. (in.) NO. OF BLADES V4S3060 300(12”) 4 V4S4060 400(16”) 4 V4S5060 500(20”) 4 V4T5060 500(20”) 4 V6T6360 630(25”) 6 V6S7160 710(28”) 6 V6T7160 710(28”) 6 VOLT (Phase) 240 (1 phase) 240 (1 phase) 240 (1 phase) 240/420 (3 phase) 240/420 (3 phase) 240 (1 phase) 240/420 (3 phase) RPM WATTS AMP 1,600 120 1,600 AIR VOLUME CMH CFM 0.5 2,250 1,325 290 1.3 5,300 3,119 1,600 300 2.3 7,450 4,384 1,600 310 1.6/0.9 7,450 4,384 1,000 470 2.1/1.2 11,800 6,945 1,000 720 3.5 16,000 9,416 1,000 700 2.7/1.6 16,050 9,446 INDOLA V Series Panel Fans (Stainless Steel Fan Blades w/ Polypropylene Frame) DIMENSIONS (mm.) F A E G D B C MODEL A B C D E F G V4S3060 350 395 173 67 106 314 20 V4S4060 444 495 186 80 106 430 20 V4S5060 565 635 176 60 116 535 20 V4T5060 565 635 213 80 133 527 10 V6T6360 750 835 220 100 120 660 30 V6S7160 810 885 230 90 140 740 30 V6T7160 810 885 230 90 140 740 30 (Pst - Pa) PERFORMANCE DATA (m3h) 120 1 2 3 4 5 6 7 100 7 80 6 40 4 2 60 5 3 = = = = = = = V4 S30 6 0 V4 S 4 0 6 0 V4 S5 0 6 0 V4T5 0 6 0 V6T636 0 V6S716 0 V6T 716 0 1 20 0 2000 4000 6000 8000 10000 12000 14000 16000 [m3/h] *Allaircapacitieswithoutwireguard. 33 PROPELLER FANS V SERIES PANEL FANS STAINLESS STEEL FAN BLADES POLYPROPYLENE FRAME VWZ 630 / 710 VDZ 630 / 710 WITH DESCRIPTION Plate mounted axial flow fans with high air-capacity and minimumpowerconsumption.Wallmountingplateis fabricated from reinforced polypropylene for horizontal or vertical mounting. TECHNICAL DETAILS electrIcal sPecIFIcatIons VWZ630/710:220-240V/60Hz,1Phase VDZ630/710:220-240V/380-415V/60Hz,3Phase ConformstoIEC/CEEElectricalSafetyStandards Motors Direct drive inside-rotor motors with fully enclosed and greased for life ball bearings according to IEC 34-1 standard. Motor windings are provided with a multiple impregnation for maximum protection against humidity. ThemotorshaveinsulationClassBwindingsandare protectedtoIP54. The integral overheat protector is fitted in the motor. Capacitors and wiring block are situated inside the motor housing directly under the cover. Fully speed controllable by electronic regulator, transformer or frequency controller. APPLICATIONS Perfectly suitable where higher air capacities in combination with elevated static pressures are required. Highlyrecommendedfor: •largerindustrialbuildings •largerwarehouses aMBIent teMPeratUre Suitableforuseinambienttemperaturebetween-20°C •indoorcarparks •variousindustrialapplications and+70°C. •airhandlingunits •livestockhouses TECHNICAL SPECIFICATIONS 34 MODEL BLADE Ø mm. (in.) RPM WATTS AMP VWZ 630 630(25”) 1,115 460 VWZ 710 710(28”) 1,115 VDZ 630 630(25”) VDZ 710 710(28”) AIR VOLUME CMH CFM 2.00 13,200 7,769 780 3.20 17,710 10,423 1,115 400 1.70 13,200 7,769 1,115 570 2.70 17,880 10,523 DIMENSIONS (mm.) A B F A B E D C MODEL A B C D E F VWZ 630 750 835 340 220 120 630 VWZ 710 810 885 355 215 140 710 VDZ 630 750 835 340 220 120 630 VDZ 710 810 885 355 215 140 710 PERFORMANCE CURVE NOTE: AircapacityvaluesaredeterminedbytheuseoftheDIN24163/NEN1048-IItestingmethod.Thevaluesobtainedfollow closelythosewhentestingaccordingtoBS848part1.Theaircapacityvaluesaremeasuredovertheairflowtestrig.Air capacity values given in cubic meters per hour (m3h).StaticpressurevaluesaregiveninPascal:Pst(Pa). 35 PROPELLER FANS COMPACT PANEL FANS POLYPROPYLENE FAN BLADES POLYPROPYLENE FRAME WIF 400 / V4S4960 WITH DESCRIPTION A very compact fan with non-protruding motors and equipped with polypropylene fan blades and rigid polypropylene wall mounting plate. Stainless steel motor supports. The fan is usable in both air directions byturningtheblades180°. TECHNICAL DETAILS electrIcal sPecIFIcatIons WIF400/V4S4960:220-240V/60Hz,1Phase ConformstotheIEC/CEEelectricalsafetystandards Motors Totally enclosed direct drive motor, greased for life, maintenance-freeballbearingsaccordingtoIEC34-1 standard, is designed for continuous running. The motors are fitted with internal over-heat protection. The leads in the terminal box allows the protector to be wired in series with the winding giving automatic restart or to a starter giving manual restart. Motor windings are provided with multiple impregnation for maximum protection against humidity. APPLICATIONS For use in any installation that requires standard airflow with or without variable speed control with easy and flexible installation. Axial types available with various mounting possibilities. Suitable for cooling, heating or ventilation and many other situations where a fan is The wiring box conforms to IP55 standard, with required. The fan may be used indoors and outdoors capacitors, is connected by a 7 core cable of (IP55). approximately 80 cm. length to motor. Insulation Class:F. aMBIent teMPeratUre Suitableforuseinambienttemperaturebetween-20°C and+70°C. TECHNICAL SPECIFICATIONS 36 MODEL BLADE Ø mm. (in.) RPM WATTS AMP WIF 400 400(16”) 1,600 250 V4S4960 500(20”) 1,640 420 AIR VOLUME CMH CFM 1.10 5,400 3,178 2.10 8,400 4,944 INDOLA Compact Panel Fans (Polypropylene Fan Blades w/ Polypropylene Frame) DIMENSIONS (mm.) A F B A B D E C MODEL A B C D E F WIF 400 444 495 150 30 113 400 V4S4960 565 635 150 30 143 500 PERFORMANCE CURVE 1 = WIF 400 2 = V4 S 4 9 6 0 1 2 NOTE: AircapacityvaluesaredeterminedbytheuseoftheDIN24163/NEN1048-IItestingmethod.Thevaluesobtainedfollow closelythosewhentestingaccordingtoBS848part1.Theaircapacityvaluesaremeasuredovertheairflowtestrig.Air capacity values given in cubic meters per hour (m3h).StaticpressurevaluesaregiveninPascal:Pst(Pa). 37 PROPELLER FANS FLANGED TUBE SERIES COMPACT SHORT CASE FANS TWIF 400 / T4S4961 DESCRIPTION The compact design of the motor and impeller assembly, mounted inside the slim outer casing, features a complete fan unit which is both shorter and lightweight. The casing is made of rolled steel plate and epoxy-powder coated (off-white) for full anti-corrosion resistance. The flange dimensions and hole positions of the drilled flanges at both ends of the casing are to ISO6580standards. The dynamically balanced stainless steel impellers are resistant to outside conditions and abrasive airstream. The impellers are factory set to the exact blade angle. The direction of airstream is indicated on the fan unit by an“arrow.”Theunitallowsinstallationatanyangle. TECHNICAL DETAILS electrIcal sPecIFIcatIons TWIF400/T4S4961:220-240V/60Hz,1Phase ConformstoIEC/CEEElectricalSafetyStandards AccordingtoRadioSuppressionGuideline82/499/EEC APPLICATIONS Forinstallationinallkindsofductsystems: •Workshops Motors Direct drive motors with fully enclosed, greased for •CommercialBuildings life ball bearings according to IEC 34-1 standard. •IndustrialBuildings ThemotorshaveinsulationClassFwindingsandare •Carparks •StationBuildings protectedtoIP55. The integral overheat protector is fitted in the motor. Excellent speed control by either two or three wire connection.Thewiringbox(IP55),withthecapacitors, is mounted on the fan casing outside the airstream. aMBIent teMPeratUre Suitableforuseinambienttemperaturebetween-20°C and+70°C. TECHNICAL SPECIFICATIONS 38 MODEL BLADE Ø mm. (in.) RPM WATTS AMP TWIF 400 400(16”) 1,550 230 T4S4961 500(20”) 1,600 440 AIR VOLUME CMH CFM 1.50 5,390 3,172 2.30 8,420 4,955 INDOLA Flanged Tube Series Compact Short Case Fans DIMENSIONS (mm.) E F C A B MODEL A B C E (N) F TWIF 400 450 486 160 12(8x) 400 T4S4961 560 596 170 12(12x) 500 PERFORMANCE CURVE 1 = TWIF 400 2 = T4 S 4 9 61 1 2 NOTE: AircapacityvaluesaredeterminedbytheuseoftheDIN24163/NEN1048-IItestingmethod.Thevaluesobtainedfollow closelythosewhentestingaccordingtoBS848part1.Theaircapacityvaluesaremeasuredovertheairflowtestrig.Air capacity values given in cubic meters per hour (m3h).StaticpressurevaluesaregiveninPascal:Pst(Pa). 39 RECIRCULATION FANS CASING / CONE FANS EMI 130 DESCRIPTION The aerodynamic design casing of EMI 130 fan with its 3-dimensionally shaped polypropylene blades provide maximum air performance ideal for poultry, piggery and greenhouse applications. The metal casing and the integrated, aerodynamic construction create a strong unit and makes it more stable through the smooth connection of the compact pulley and the diagonal supports. The non-corrosive attachments, aluminum pulley and the highly protected impellers make EMI 130 withstand the aggressive climates, thus providing consistent maximum performance for a long period of time. TECHNICAL DETAILS electrIcal sPecIFIcatIons EMI130 :240/420V/60Hz,3Phase :240V/60Hz.,1Phase Motor Maintenance in a jiffy. The wire guard of the EMI 130 Withits3-phasevariablespeedmotor(1-phase motor Casing Fan can be opened and hinged on either side also available), the fan provides an excellent ratio thus cleaning time can be finished more quickly and accurately. All the 4 corner covers open up together with of airflow to electricity consumption thus saving on the removal of the guard. The covers already prevent energy and installation costs. The fan motor is dust most dust collection and any remaining parts can be and moisture protected to IP55 standard. Insulation removed quickly. All other parts are within reach and ClassF(155°C). 40 rather easy to clean for optimal hygiene. The stretchable V-belt can be installed without belt tightener and does not need adjusting after installation. This belt provide a long lifetime for the pulley and hub construction of the fan. Logistic wise construction. The symmetric parts of the casing and internal construction, including the corner covers, allow easy installation. All the parts are easy to assemble and are partly exchangeable. The number of connections is absolutely reduced to a minimum. To prevent problems during installation, the EMI 130 Casing Fan is designed for a “one-way” construction: the motor, V-belt, pulley and impellers form one unit. Wide range of options. For standard applications, the 3-blade version of EMI 130 Casing Fan can be used, however; for higher pressures (from 0.25 - 0.4 SP) a 5-blade version is available. The EMI 130 Cone Fan, with shutters on the inside, provides further possibilities for increasing the airflow capacity. The cone is made of 4 easy to assemble parts. INDOLA EMI 130 Casing / Cone Fans TECHNICAL SPECIFICATIONS MODEL BLDE NO. OF mm. in. BLDES CT. V4D1422 | 21236 V4D1550 | 21236 (blue blades) PM TTS 1300 (51”) 3 240/420 (3 phase) I VOLUME MP 240 (1 phase) V4E1521 | 21236 EMI 130 VOLTS Phase CMH CFM 45,600 26,836 7.1 580 1,650 5.2/3.0 DIMENSIONS (mm.) MODEL A B C D E F G EMI 130 Casing Fan 1380 1380 271 360 96 – – EMI 130 Cone Fan 1380 1591 1276 782 275 133 85 PERFORMANCE CURVE 41 RECIRCULATION FANS BASKET FANS K4D130 / K4E5011 DESCRIPTION In factories, an optimal distribution of air is absolutely necessary. The temperature in factory halls can increase fairly quickly in the summer months. This has direct consequences for productivity and working conditions. Solutions for cooling the air in factory halls are often too expensive or technically not feasible. RecirculationBasketFansareanidealsolutioninsuch cases. A combination of air circulation and air extraction solves the problems described above. Constant air distribution also ensures a pleasant work environment and eliminates heat stress. The Recirculation Basket Fans provide a constant supply of cool air. In addition, the air is circulated throughout the building, which means that blind areas are avoided. This keeps the air supply in the building stable. Onthemarketitisadvisedtoinstallafanevery12-14 meters. However the number of rows and fans needed in the building depends on the density, construction and utilization, as well as on local climatic conditions. The low noise level of the fan enables a calm environment. For security reasons the 3-blade fan is provided with a basket on both sides. The unit is very easy to install at thetrussofthebuilding.Becauseofthespecialbelt (K4D130model),abelt-tightenerisnotnecessary. K4D130-3PP-55FC ADVANTAGES • Highlevelofairmovement(upto48,000m3h at 0 Pa) • High throw • Variable speed • Simple, user-friendly construction • High efficiency • Low noise level • IP55ingressprotection K4E5011 | 21100 TECHNICAL SPECIFICATIONS MODEL BLADE Ø mm. (in.) VOLTS (PHASE) RPM WATTS AMP K4E5011 | 21100 500(20”) 240(1PH) 1,600 310 515 1,240 K4D130-3PP-55FC 1300(51”) 240V/420V(3PH) 42 INDOLA Recirculation Basket Fans AIR VOLUME CMH CFM 1.4 7,850 4,620 4.0/2.3 48,000 28,248 DIMENSIONS (mm.) MODEL A B C D 1350 1635 364 1300 K4E5011 | 21100 K4D130-3PP-55FC PERFORMANCE CURVE Angle (º) Fan distance (m) Fan distance Angle (º) K4D130 Ex.: Ø Impeller = 90 cm Angle = 15 º Fan distance = 9 m 60 70 80 90 100 110 Impeller diameter (cm) 120 130 140 43 MISTING FANS LOW PRESSURE NOZZLE SYSTEM ADVANTAGES TB4E / TB4D / TB6E • Lowers the temperature in greenhouses • Reduces heat stress • Reliablesystem:3-yearwarrantyonthefanmotor • Optimal distribution of the mist • Flexible to adapt to local circumstances • Low maintenance system • Climatecontrolatlowcost • Easy to install coolInG During hot periods it becomes necessary to reduce the temperature in the barns. The highly productive animals, dairy, pork and poultry, suffer from heat stress and technical results (feed intake, lower fertility, etc.) are significantly reduced. The Indola Low Pressure Nozzle System Misting Fan evaporates very small water drops to reduce the temperature in the barns. The drops are distributed through the combination of an ultra fine nozzle system and a recirculation fan. By using up to 8 separate nozzle outlets, the water is constantly and immediately evaporated by the high output of air; thus, the temperature is reduced significantly. The heat stress for production animals is a critical parameter to observe. Too much heatstresscanreducemilkproductionupto25%orlimitweightgainfor finishingpigsupto40%.WiththeIndola Low Pressure Nozzle System Misting Fan, the farm manager is able to adapt the temperature at animal level to a more than satisfactory level. The recirculation fan enables the misted air to be distributed evenly throughout the house. relIaBle sYsteM All the components and parts of the system used are specifically designed for the aggressive climates in barns. The Indola Low Pressure Nozzle System Misting Fan is known for its reliability and resists 44 INDOLA Low Pressure Nozzle System Misting Fans high temperatures and severe climatic conditions in the dairy, pork or poultry houses. A 3-year warranty on the watertight motor (IP55)isoneofthewaystoexpress the high durability. The nozzles are made of chemical and acid-resistant material. The bridgeless design of the nozzles eliminates dripping. If the water pressure gets below 4 bar, the water output by the nozzles automatically stops. Evaporating at too low water pressure increases the chance of water drops. MIst dIstrIBUtIon The high throw of the fan assures an optimal spread of the water mist creates an equal climate throughout the barn. Since the nozzles are incorporated in the grill, air volume losses are hardly existing. At a relativelylowpressureof4bar,the nozzles distribute average drops of 100 micron or MMD (mass medium diameter). Under suitable conditions these drops evaporates instantly. Onaverage60%ofthedropssizes arebetween0-50microns. FleXIBIlItY The Indola Low Pressure Nozzle System Misting Fan offers the flexibility to install 1 - 8 nozzles. In the standard execution of the misting fan, 8 nozzles are used. Due to local circumstances (humidity, temperature, etc.), the number of nozzles can be lower. MaIntenance The nozzles can easily be changed and are, if necessary, replaced in seconds. The front grille can easily be replaced by a new grill with incorporated nozzles. The motor and fan can be cleaned with a high pressure system to optimize hygiene. Another unique feature of the system is the ability to flush the water line. To be able to clean the water tubes thoroughly and to avoid stagnant water, the tubes are installed in an open circle. clIMate control at loW cost The recirculation fan can be easily integrated in existing climate control systems. A water pump creating a waterpressureof4-5barisarelativelowinvestmentforacoolingsystem.Throughatimerand/orahygrostat/ thermostat, the manager can constantly influence the temperature and humidity in the house in a simple way. The Indola Low Pressure Nozzle System Misting Fan has the unique feature that it can be used as a cooling systemANDasarecirculationsystemtocreateanuniformdistributionoftheheat;reallya“2-in-1”system! easY to Install All the connections of the water line are easily fixed in a robust way. The complete water distribution set is integratedinthefangrillandthereforeeasytomount.Therecirculationfanissuppliedwith2suspensionholes andisinstalledinajiffy.Becauseofthelowpressuresystemstandardwaterdistributionlinescanbeusedfor thewatersupplyoftheindividualfans.Thenozzlesystemwillbedeliveredasaseparateset,whichcontains: -wireguardfor50cmgreenhousefan -8nozzleswithhosesandcanbeeasilymountedonthe50cmrecirculationfan. TECHNICAL SPECIFICATIONS MODEL BLADE Ø mm. RPM VOLT dB (a) 7m THROW (m) WATTS AMP TB4E50Q 518 1,400 230 55 58 390 TB4D50Q 518 1,400 230/400 55 58 TB6E50Q 518 900 230 51 53 AIR VOLUME CMH CFM WEIGHT (kg.) 1.8 7,760 4,567 17 400 1.9/1.1 7,760 4,567 17 300 1.4 7,060 4,155 17 WATER SUPPLY DATA NO. OF NOZZLES 1 to 8 nozzles SUPPLY PER NOZZLE 7.5 liter/hour (at 4.0 bar) SUPPLY PER FAN 60 liter/hour (at 4.0 bar) REQUESTED WATER PRESSURE 4 - 5 bar NO. OF FANS flexible amount per area/animal/local condition 45 VENTILATING FANS INDUSTRIAL OSCILLATING FANS • Over 30 years in fan manufacturing expertise • High attention to product quality • Materials from Japan WW 255 / WS 255 WSW 180 TECHNICAL DETAILS Motor : squirrel cage induction type with capacitor start and run Guard : highqualitychromium-platedordinaryormodified wire guard with easy locking clips Fanblade : 18”(457mm.)or25½”(648mm.)reinforceddiecast aluminum blade Speed : 3speedcontrol Adjustment : adjustable tilt angle from 15° downwards to 60° upwards Swivel : 90°,130°orfixed Voltage : 200-240V,60Hz,1-phase Pedestaltype : heightadjustabletubewithstablecastironbase and non scratch foot pads Wallmounted : robustbendtubewithsafetywallmountkit WS-255 Modified Guard WSW-180 WW-255 TECHNICAL SPECIFICATIONS MODEL WSW-180 BLADE SIZE SPEED in. (mm.) 18(457) WW-255 25.5(648) WS-255 46 AIR VOLUME RPM POWER (Watts) CURRENT (Amp) NOISE LEVEL dB(A) CMH CFM 1 1,100 83 0.38 40 144 85 2 1,250 98 0.47 44 186 110 3 1,400 124 0.60 48 229 135 1 1,100 130 0.50 48 9,089 5,349 2 1,250 150 0.70 52 9,881 5,815 3 1,400 180 0.80 57 10,980 6,462 RIO Industrial Oscillating Fans DIMENSIONS (mm.) MODEL WSW-180 WW-255 WS-255 B BLADE SIZE A 18” 20” 455 508 25½” 27” 84” 64¼” 14” 648 685 2135 1630 355 max. min. C D E F G WEIGHT (kg.) 13” 23” 18” 355 584 455 22” 32” 18” 5½” wall pedestal 560 810 455 140 13.43 21.56 PERFORMANCE CURVE (1,400 RPM) 47 VENTILATING FANS INDUSTRIAL EXHAUST FANS • Over 30 years in fan manufacturing expertise • High attention to product quality • Materials from Japan WV SERIES TECHNICAL DETAILS Motor : totally enclosed motor with ball bearings; the capacitorishousedinthemotorforfansof12”, 15”,18”and24” Fanblade : 4 pressed steel blades fitted for cast aluminum alloy hubs, fully balanced after assembly (9½” fans are of 6 blades) Mountingarms : withresilientcushiontoreducethetransmission of vibration to the fixing surface Voltage : 1-phase;100/110,110/115,200/230or230/250V 3-phase;200/220,220/250,346/380or380/440V other voltages are available upon request Finish : glossy grey enamel; other finishes are available upon request WV21 (9.5”) front WV21 (9.5”) 6-blades TECHNICAL SPECIFICATIONS 48 MODEL BLDE SIE in. mm. VOLTGE WV21 - 9.5 9½(241) 220 WV21 - 12 12(305) WV21 - 15 I VOLUME POE atts CUENT mp NOISE LEVEL dB CMH CFM 1,300 40 0.25 48 747 440 220 1,400 115 0.60 57 1,937 1,140 15(381) 220 1,400 180 0.90 63 3,908 2,300 WV21 - 18 18(458) 220 1,400 315 1.60 67 6,457 3,800 WV21 - 24 24(610) 220 1,400 990 5.00 73 16,142 9,500 PM RIO WV Series Industrial Exhaust Fans DIMENSIONS (mm.) MODEL BLADE SIZE A B C D WV21 - 9.5 241 294 244 273 157 WV21 - 12 305 388 325 312 244 WV21 - 15 381 473 400 370 267 WV21 - 18 458 559 476 440 334 WV21 - 24 610 725 632 570 370 PERFORMANCE DATA CFM MODEL at static pressure of WG at free air flow 0.05 0.10 0.15 0.20 0.30 0.40 WV21 - 9.5 440 370 — — — — — WV21 - 12 1,140 1,050 960 860 710 460 — WV21 - 15 2,300 2,200 2,100 2,020 1,900 1,600 1,300 WV21 - 18 3,800 3,750 3,650 3,600 3,500 3,200 2,800 WV21 - 24 9,500 9,400 9,150 8,900 8,600 8,000 7,000 49 TUBE AXIAL FLOW FANS BELT-DRIVEN SERIES • Over 30 years in fan manufacturing expertise • High attention to product quality • Materials from Japan WAB SERIES TECHNICAL DETAILS Motor Fanblade : totallyenclosedmotor : die-cast aluminum alloy, angle of the blade c an be adjuste d Casing : steel,hotdipgalvanized Accessories(optional) : rearfront-safetyguard companion flange TECHNICAL SPECIFICATIONS MODEL BLADE SIZE in. (mm.) VOLT (PHASE) WAB-1932 19 (490) 380 (3 PH) AIR VOLUME RPM POWER (HP) CURRENT (Amp) NOISE LEVEL dB(A) CMH CFM 2,800 4 6.4 82 13,423 7,900 DIMENSIONS (mm.) A B D F H E C MODEL WAB-1932 50 A B C D E 23⅛in. 21⅜in. 17 in. 15⅛in. 23½in. 588mm. 542mm. 432mm. 384mm. 598mm. RIO WAB Series Tube Axial Flow Fans F Nos. 12 G Dia. 1/2in. 13 mm. Nos. 8 H 31⅞in. 810 mm. ROBOTECH JET FANS UNDERGROUND PARKING EXHAUST FANS TIV 200D / 250D CBF 350S APPLICATIONS Ventilation of underground parking lots, shopping centers, factories and warehouses. FEATURES • Securesagoodspaceduetonon-installationofduct. • Goodinstallationandmaintenance. • IP52motor. • ClassEinsulation. TIV 200D / 250D CBF 350S (Round type, 1 nozzle outlet) LxWxH = 1340 x 410 x 410 mm DIMENSIONS (mm.) 250 Model No. TIV 200D TIV 250D 45 Ø 190 Ø 215 Ø 295 675 565 70 245 160 245 295 990 TECHNICAL SPECIFICATIONS MODEL BLDE SIE in. mm. PHSE VOLTS Hz PM TTS TIV 200D 8(200) 1/220 3120 TIV 250D 10(250) 1/220 3135 CBF 350S 1/220 I VOLUME MPS NOISE LEVEL dB CMH 185 0.90 59 220 1.07 600 CFM STTIC PESSUE mm T. kg. 1,800 1,059 30.0 18 60 2,400 1,412 40.0 18 63 3,500 2,059 5.0 40 ROBOTECH Underground Parking Exhaust Jet Fans 51 PERFORMANCE CURVE 1 = TIV 200D 2 = TIV 250D 40 Pressure (mmAq) 35 30 25 20 2 1 15 10 5 0 400 800 1200 1600 Air volume (m3/h) 52 2000 2400 2800 High Capacity Fans INLINE SQUARE CENTRIFUGAL FANS ISQ Range APPLICATIONS Ductsupply/exhaust,filtersupply/exhaust,lownoise cabinet, explosion resistant exhaust PERFORMANCE RANGE VolumeRange:upto49,000CMH StaticPressureRange:upto920Pa WheelDiameter:300-1000mm Available:3Phase,380V/440V PRODUCT FEATURE • AMCAcertifiedsoundandairperformance • WheelbalancinglevelG2.5 • Multi-discharge; motor can be multi-positioned • “Wind-surferII”designbackwardinclinedcentrifugal wheel, non-overloading • Precise hyperbola Venturi inlet; noise and energy loss caused by turbulence are reduced • Square plug fan structure, easily installed TECHNICAL SPECIFICATIONS • Fan Type - belt drive or direct drive; fan is inline cetrifugal type, with aluminum backward inclined centrifugal wheel. The fan wheel Venturi have round curved section to smoothly transit the air to the wheel cone. The wheel is balance tested statically anddynamicallytoG2.5levelasperISOstandard No.1940. • Motor-isIP54withinsulationclassFandiscarefully matched to the fan load. Motor bearings are ball type and need no lubrication. • Fan Housing Material - the fan housing is made of heavy gauge galvanized steel panel with thickness adequate to support drive and motor. The square housing has rectangular sleeve flanges to avoid round/square transducer duct. The housing has optional discharge directions and large access doors on both sides which can be used to replace the motor without removing the ready made duct. • Drive (belt drive model only) - Shaft: fan shaft is heat treated through soaking furnacetoHB370hardnesslevel,andthesurface hard film corrosion treated. The fan shaft is balanced together with the wheel. Shaft design speed at least exceeds 25% of the maximum fan operation speed. 54 - Pulleys: fan pulleys are sized for a minimum of 150% of driven horsepower. The pulleys made of cast iron type, keyed and securely attached to the wheel and motor shafts. For easy removal of the pulleys,conical(QD)typebushingsareutilized. - Bearings: are selected for a minimum (L-10) life in excess of 80,000 hours at maximum rated operating speed. Bearing type are permanently sealed, relubricable pillow block metal ball bearings. - Drive Support: drive assemblies are supported by heavy gauge powder coated steel. The belt tension are adjusted through the motor support plate; fan shaft and motor shaft is always parallel. - Protectioncover-ashaft/bearingcoverandabelt cover are provided as standard configuration for indoor application. If the fan is outdoor installed, the motor and other drive parts shall be covered by a weather hood (optional accessory) to assure lasting durability. INFINAIR ISQ Range In-line Square Centrifugal Fans TYPICAL INSTALLATION The ISQ is provided with universal mounting feet for installation in any horizontal or vertical position. These feet are shipped loose for field installation in the desired location. MOTOR WEIGHT TABLE The ISQ configuration allows air to exit from any one sides except the motor and motor opposite side of the unit at jobsite. Remove the side panel of the desired outlet direction, change it to flange, and seal the original flange, all the above can be easily finished by contractors at jobsite. MOTOR WEIGHT (Kg) POWER (kW) 2P 4P 6P 8P 0.18 14 13.5 14 16 0.25 14.5 14 14.5 17 0.37 15 14.5 16 24 0.55 15.5 15 17 28 0.75 15 16 22 30 1.1 16 21 24 32 1.5 21 23 32 40 2.2 24 33 41 64 3 33 35 63 78 4 41 41 72 105 5.5 63 65 81 115 7.5 70 76 118 145 11 110 118 145 160 15 122 137 180 235 18.5 142 170 231 290 55 OPTIONAL DISCHARGE Remark: the codes at the top left corner indicate the discharge and motor position MTDLRH Motor top, discharge is left, right and horizontal Letter explanation M : Motor T : Top D : Discharge L : Left R : Right H : Horizontal B : Bottom DDLR Direct drive, discharge is left and right Letter explanation D : Direct drive D : Discharge L : Left R : Right H : Horizontal B : Bottom 56 CENTRIFUGAL UTILITY SET CUS Range APPLICATIONS Process supply / exhaust, kitchen grease exhaust, explosionresistantexhaust,ductsupply/exhaust PERFORMANCE RANGE VolumeRange:upto55,000CMH StaticPressureRange:upto1,100Pa WheelDiameter:300-1000mm Available:3Phase,380V/440V PRODUCT FEATURE • AMCAcertifiedsoundandairperformance • WheelbalancinglevelG2.5 • “Wind-surfer II” type aluminum backward inclined centrifugal wheel, non-overloading • Continuously welded housing, non-leak, rigid structure, suitable for all outdoor weather condition • Compactspace-savinghousingdesign • Standard epoxy powder coating TECHNICAL SPECIFICATIONS • Fan Type - belt drive or direct drive. Fan wheels are • Drive (belt drive model only) - Shaft: fan shaft is heat treated through soaking centrifugal, backward inclined, and constructed of furnacetoHB370hardnesslevel,andthesurface aluminum. The fan wheel Venturi have round curved hard film corrosion treated. The fan shaft is section to smooth the air flowing to the wheel cone. balanced together with the wheel. Shaft design The wheel is balance tested statically and dynamically speed at least exceeds 25% of the maximum fan toG2.5levelasperISOstandardNo.1940. operation speed. • Motor-isIP54withinsulationclassFandiscarefully Pulleys:fanpulleysaresizedforaminimumof150% matched to the fan load. Motor bearings are reof driven horsepower. The pulleys made of cast iron lubricable ball type. Motor and drives are mounted on type, keyed and securely attached to the wheel and vibration isolators, and out of the air stream to avoid motor shafts. Motor pulleys are adjustable for final grease or dirt accumulation. system balancing. For easy removal of the pulleys, • Structure - AMCA standard Spark B resistant conical(QD)typebushingsareutilized. construction of the fan’s aluminum wheel and inlet. Bearings: are selected for a minimum (L-10) life in An access door is provided to remove possible debris excess of 80,000 hours at maximum rated operating inside the scroll. speed. Bearing type are permanently sealed, re• Fan Housing Material - the fan casing is made of lubricable pillow block metal ball bearings. steel with thickness adequate to support drive and - Drive Support: drive assemblies are supported by motor. The scroll is fully welded. The fan surface is heavy gauge powder coated steel, mounted on alkali cleaned and phosphated, with electrostatically vibration isolators. The belt tension are adjusted black epoxy powder applied. through the motor support plate; fan shaft and motor shaft is always parallel. - Protectioncover-ashaft/bearingcoverandabelt cover are provided as standard configuration for indoor application. If the fan is outdoor installed, the motor and other drive parts shall be covered by a weather hood (optional accessory) to assure lasting durability. Scroll is fixed by 8 housing bolts; housing can be rotated at jobsite within limited angle. INFINAIR CUS Range Centrifugal Utility Set 57 OPTIONAL DISCHARGE The rotation is identified from the view of motor side. The fan rotation must be specified before ordering; otherwise the fan is difficult to be installed if the discharge direction is inconsistent with the design. MOTOR WEIGHT TABLE POWER (kW) 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 58 2P 14 14.5 15 15.5 15 16 21 24 33 41 63 70 110 MOTOR WEIGHT (Kg) 4P 6P 13.5 14 14 14.5 14.5 16 15 17 16 22 21 24 23 32 33 41 35 63 41 72 65 81 76 118 118 145 8P 16 17 24 28 30 32 40 64 78 105 115 145 160 LOW NOISE CENTRIFUGAL CABINET FANS ICC Range APPLICATIONS Inlinesupply/exhaust,smokeremoval PERFORMANCE RANGE VolumeRange:upto120,000CMH StaticPressureRange:upto1,600Pa WheelDiameter:280-1000mm Available:3Phase,380V/440V PRODUCT FEATURE • Both forward and backward centrifugal wheels: application-oriented • WheelbalancinglevelG2.5 • AirinletspaceconformtoAMCArecommendedsize: turbulence reduced • Air-tight casing structure, low noise design, high efficiency • Certifiedforsmokeremoval • Flexible solutions for individual customer needs various outlet directions available; double-speed motor available; floor-mounted, over-hanging installation Common features for DWDI (Double Width Double Inlet) centrifugal fan inside ICC: • Mold fabricated venturi inlets make sure the one • High quality fabrication method of the DWDI fan housing piece outline are smooth; which assures stable - All scroll fan housing performance are “Pittsburgh” method • WheeldesignisbasedonadvancedGermanaerojoined, and the 2 pieces dynamic technology, and optimized via the most upof housing side panels to-dateCADhydro-fieldsimulatingsoftware are joined at the same • Thebladesarefabricatedwithadvancedtechnology, o ne t im e p r o c e dure, assuring the mass and stress are are evenly which results in almost distributed, which is suitable for long-term function “Pittsburgh” method joint panels zero air leakage • TheDWDIfaninsideICCbearsAMCAsound&air - The housing are highly performance seal stable, rigid for vibration, • Highqualitypartsselected and the low sizing tolerance makes sure the aero- Superior quality redynamic performance are precisely kept lubricapable ball bearings with cast iron pillow block, lifeexceeds(ABMA)L10: 80,000 hours - Precisely lathe turned, ground and heat treated through soaking furnace Bearing and shaft to the hardness level of HB370 - Power transmission drive featuring advanced taper bushingdesign,anddrivepowerselectionis120% of the maximum power under the specified RPM INFINAIR ICC Range Low Noise Centrifugal Cabinet Fans 59 OPTIONAL CONFIGURATIONS Motor is positioned on top of the unit away from the air flow DWDI inside: forward curved type Reinforcing threaded rod for forward curved wheel CONFIGURATION WHEEL TYPE USAGE HOUSING TYPE HOUSING MATERIAL 60 DWDI inside: backward inclined type Backward inclined wheel with reinforcing rod CLASSIFICATION Backward inclined wheel with V-type performance baffle DESCRIPTION Forward curved Lower noise when normal static pressure required Backward inclined Higher static pressure available for same air volume, and nonoverloading General ventilation Motor is positioned within airflow; not suitable for smoke removal Smoke removal Motor is located on the top of the unit and outside the air stream; for both smoke removal and general exhaust Single wall For general ventilation requirement Double wall with acoustical insulation For low noise application Galvanized steel Galvanized housing material is more economic Electrostatic epoxy powder coating More durable and corrosion resistant ROOFTOP CENTRIFUGAL EXHAUST FANS RTC Range APPLICATIONS Rooftop exhaust, explosion-proof exhaust, smoke removal PERFORMANCE RANGE VolumeRange:600to50,000CMH StaticPressureRange:100to1,000Pa WheelDiameter:300-1000mm Available:3Phase,380V/440V PRODUCT FEATURE • AMCAcertifiedsoundandairperformance • WheelbalancinglevelG2.5 • Active cooling • “Wind-surferII”designbackwardinclinedcentrifugal wheel • Aluminum construction • Explosive air exhaust for direct drive TECHNICAL SPECIFICATIONS • Fan Type - fan is rooftop centrifugal exhaust type, • Structure - the windband have a rigid internal support structure to protect the fan from heavy wind, with aluminum backward inclined centrifugal wheel. the internal structure is water-tight during heavy rain. The fan wheel Venturi have round curved section to Motor and drive support panels are anti-corrosion smoothly transit the air to the wheel cone. The wheel treated steel panel. isbalancetestedstaticallyanddynamicallytoG2.5 • Motor-isIP54withinsulationclassFandiscarefully levelasperISOstandardNo.1940. matched to the fan load. Motor bearings are ball type • Fan Housing Material - the fan housing, wheel and and need no lubrication. curb cap are made of heavy gauge aluminum alloy. • Drive (belt drive model only) - Shaft: fan shaft is heat treated through soaking furnacetoHB370hardnesslevel,andthesurface hard film corrosion treated. The fan shaft is balanced together with the wheel. Shaft design speed at least exceeds 25% of the maximum fan operation speed. - Pulleys: fan pulleys are sized for a minimum of 150% of driven horsepower. The pulleys made of cast iron type. For easy removal of the pulleys, conical(QD)typebushingsareutilized. - Bearings: are selected for a minimum (L-10) life in excess of 80,000 hours at maximum rated operating speed. Bearing type are permanently sealed, relubricable pillow block metal ball bearings. - Drive Support: drive assemblies are supported by heavy gauge powder coated steel, mounted on The service switch is to be installed inside the fan or on the vibration isolators. The belt tension are adjusted roof close to the fan, the usage is to make sure the power through the motor support plate; fan shaft and supply can be reliably shut off while repairing the fan, and it motor shaft is always parallel. is not supposed to start/stop the fan for daily operation. INFINAIR RTC Range Rooftop Centrifugal Exhaust Fans 61 Installation Instruction • • • • The roof curb height shall be defined by the design engineer.Suggestedheightshallbe400-600mm according to local rainfall level. Isolation pads, steel angles and screws in this drawing are not supplied by Infinair. The elasticity of the isolation pads shall remain good when the fan load is applied, and shall not become soft even at summer high temperature situation on the roof. The rubber isolation pads should be decided according to the weight of the fan. Typically the thicknessofthepadis5mm. Service switch Conduit of the fan Roof curb fabrication • • The contractor is the only party responsible for the fabrication and procedures to make a roof curb, the wall shall be different according to the material. The concrete wall shall be between 70 - 80mm, steel structureshallbebetween30-45mm. As to the metal where the fan contact the curb in the top, a linear rubber vibration isolation pad shall be applied, also acts as seal. The thickness of the pad shall be decided according to the fan weight, and the hardness shall make sure it still maintains proper elasticity after the fan is seated. The pad can be cut from typical carpet type isolation pads and are to be provided by contractors. How to mount the fan Pull the fan curb cap on the curb, and fix it at all four sides by self-tapping screw. The fan must be kept leveled. Fix the wire Deck Electric wire run through curb to fan Wiring Instruction • • • It is recommended to run the wire indoor below the roof on electric wiring shelves, and go up through the internal side of the curb, then penetrate the conduit of the fan to the motor chamber. It is prohibited to drill holes on any part of the fan body for wiring. The rotation of the wheel must be checked after the wiring is done, reverse the fan rotation by interchanginganyof2ofthe3phaselines. How to mount the back-draft damper Make sure the damper blades can be fully open to 90 degree when the fan starts, and shut down automatically by gravity after the fan is stopped. RTC (belt drive) 62 RTC-D (direct drive) explosion air exhaust optional Active cooling: long lasting motor and bearing MOTOR WEIGHT TABLE POWER (kW) 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 2P 14 14.5 15 15.5 15 16 21 24 33 41 63 70 110 MOTOR WEIGHT (Kg.) 4P 6P 13.5 14 14 14.5 14.5 16 15 17 16 22 21 24 23 32 33 41 35 63 41 72 65 81 76 118 118 145 8P 16 17 24 28 30 32 40 64 78 105 115 145 160 63 IN-LINE MIXED-FLOW FANS IMX Range APPLICATIONS Smoke removal; dual speed; large volume supply/ exhaust; underground garage, subway and tunnel exhaust PERFORMANCE RANGE VolumeRange:500to93,000CMH StaticPressureRange:100to2,200Pa WheelDiameter:300-1,300mm Available:3Phase,380V/440V PRODUCT FEATURE • Integral with silencer section, large volume, low noise • WheelbalancinglevelG2.5 • Standalone drive chamber structure to protect motor • Direct drive, few running parts, no maintenance needed • Certifiedforsmokeremoval TECHNICAL SPECIFICATIONS • Fan Type - the IMX fan uses steel mixed-flow wheel staticallyanddynamicallybalancedtoG2.5levelas perISOstandardNo.1940. • Fan Housing Material - made of steel panel with rigid internal support structure. The strong windband support structure protects the fan from wind load; internal structure is watertight during heavy rain. • Motor-isIP54withinsulationclassF.Themotoris readily accessible for maintenance. • Drive - assemblies supported by heavy gauge powder coated steel. Fan shaft is precisely turned, heat treated and balanced. The shaft design speed exceeds25%ofthemaximumfanoperationspeed. • Disconnect Switch - is factory installed and wired to the motor compartment. INSTALLATION DETAIL How to mount the fan • • • On the ground - fix holes on base of the fan, with helix or self-tapping screws. Hoisting - overturn the fan; make the base upstraight; fix the fan on the rooftop. Upright on the roof - seat the fan on the roof curb, and fixed by self-tapping screw or expansion screw fromall4sides. • As the part where the fan contact the curb in the top, a linear rubber vibration isolation pad shall be applied, also acts as seal. The thickness of the pad shall be decided according to the fan weight, and the hardness shall make sure it still maintains proper elasticity after the fan is seated. The pad can be cut from typical carpet type isolation pads and are to be provided by contractors. Wiring • • • • • It is recommended to run the wire indoor below the roof on electric wiring shelves. Whenthefansareusedforsmokeremoval,runthe wire out of the fan. When the fans are used for clean air exhaust, let the wire go up through the internal side of the curb, then penetrate the conduit of the fan to the motor chamber. It is prohibited to drill holes on any part of the fan body for wiring. The rotation of the wheel must be checked after the wiring is done, reverse the fan rotation by interchangingany2ofthe3wires. Roof curb fabrication • 64 The contractor is the only party responsible for the fabrication and procedures to make a roof curb, the attached drawing is for reference only. Generally, concrete wall shall be between 70 - 80mm, steel structureshallbebetween50mm. INFINAIR IMX Range In-line Mixed-flow Exhaust / Supply Fans TECHNICAL DETAILS Model D1 D2 D3 n-Ød1 H L2 2P 4P 6P 8P A B 2P 4P 6P 8P C D 2P 4P 6P 8P n-Ød1 IMX 250 IMX 300 IMX 350 IMX 400 IMX 450 IMX 500 IMX 550 IMX 600 IMX 650 IMX 700 IMX 750 IMX 800 IMX 850 IMX 900 IMX 950 IMX 1000 IMX 1050 IMX 1100 IMX 1150 IMX 1200 IMX 1250 IMX 1300 65 TECHNICAL DETAILS Dimension of Shape Model 66 A B C H D 2P 4P Dimension of Roof Curb 6P 8P H1 L H2 Opening Size IMX 250 330 500 60 282 800 984 400 490 150 440 IMX 300 490 550 60 338 1005 1077 400 540 150 490 IMX 350 650 600 60 394 1210 1170 605 590 150 540 IMX 400 810 650 60 450 1415 1263 628 640 150 590 IMX 450 910 700 60 506 1510 1373 668 690 150 640 IMX 500 1010 750 60 563 1709 1535 752 740 150 690 IMX 550 1100 800 60 619 1650 1600 1410 785 790 150 740 IMX 600 1210 850 80 675 1820 1740 1590 875 840 150 790 IMX 650 1300 900 80 732 1960 1860 1770 940 890 150 840 IMX 700 1400 1000 80 788 2120 2020 1950 1020 990 150 940 IMX 750 1520 1050 80 844 2280 2170 2130 1096 1040 150 990 IMX 800 1620 1150 80 900 2410 2270 2260 1155 1140 150 1090 IMX 850 1720 1200 80 957 2540 2420 2360 1219 1190 150 1140 IMX 900 1820 1250 80 1013 2710 2560 2520 1318 1240 150 1190 IMX 950 1920 1300 80 1070 2820 2580 2540 1424 1290 200 1240 IMX 1000 2020 1400 100 1125 2970 2800 2750 1218 1390 200 1340 IMX 1050 2120 1450 100 1180 3110 2950 2860 1289 1440 200 1390 IMX 1100 2220 1550 100 1237 3050 2990 1338 1540 200 1490 IMX 1150 2330 1600 100 1294 3200 3140 1423 1590 200 1540 IMX 1200 2430 1700 100 1350 3400 3250 1542 1690 200 1640 IMX 1250 2530 1800 100 1406 3600 3440 1638 1790 200 1740 IMX 1300 2630 1900 100 1462 3800 3630 1734 1890 200 1840 SIDEWALL AXIAL EXHAUST/SUPPLY FANS WEX / WSP Range APPLICATIONS Industrialplantsidewallexhaust/supplyfan PERFORMANCE RANGE VolumeRange:400to29,000CMH StaticPressureRange:40to300Pa WheelDiameter:250-550/600-900mm Available:3Phase,380V/440V PRODUCT FEATURE • Forward sweeping blades; cut into air progressively, high efficiency, low noise • WheelbalancinglevelG2.5 • Direct connection with square wall opening • Maintenance-free motor • Optional weatherhood, insect screen and damper 250-550mm diameter wheel 600-900mm diameter wheel TECHNICAL SPECIFICATIONS • Fan Type-sidewallaxialflowsupply/exhaustfanwith forward sweeping steel or aluminum blades, and the blades strengthened by slots to reduce partial stress. Under solid support, the vibration speed peak value islowerthan4.5mm/s,vibrationscopepeaktopeak value is lower than 0.9x105 mm/RPM. The blades and motor are statically and dynamically balanced to G2.5levelasperISOstandardNo.1940. • Fan Housing Material - is made of galvanized steel(option:blackepoxypowdercoating)insquare shape, motor supporting structure is solid to prevent resonance during operation. A safety mesh is installed in the indoor side to prevent foreign material to be sucked into the fan. • Motor-isIP54withinsulationclassF.Themotoris located in the airstream for effective cooling. Black epoxy powder coating option INFINAIR WEX / WSP Range Sidewall Axial Exhaust / Supply Fans 67 WEX (Exhaust Fan) WSP (Supply Fan) TECHNICAL DETAILS 68 Model Volt V Hertz Hz Current A Motor W Power W Speed RPM Noise dB(A) Capacitor μF WEX/WSP-250D4 380 50 0.15 60 50 1420 55 - WEX/WSP-250E4 220 50 0.25 60 50 1350 55 3 WEX/WSP-300D4 380 50 0.20 80 70 1400 58 - WEX/WSP-300E4 220 50 0.37 80 68 1380 58 3 WEX/WSP-350D4 380 50 0.35 150 115 1380 62 - WEX/WSP-350E4 220 50 0.70 150 105 1360 62 4 WEX/WSP-400D4 380 50 0.40 180 140 1400 68 - WEX/WSP-400E4 220 50 0.80 180 130 1400 68 6 WEX/WSP-450D4 380 50 0.52 250 220 1350 70 - WEX/WSP-450E4 220 50 1.15 250 200 1360 70 8 WEX/WSP-500D4 380 50 0.70 250 220 1350 70 - WEX/WSP-500E4 220 50 1.75 250 200 1200 69 10 WEX/WSP-550D4 380 50 1.20 550 480 1300 70 10 WEX/WSP-550E4 220 50 2.10 550 494 1180 68 WEX/WSP-600D4 380 50 3.00 1500 1400 1410 <80 WEX/WSP-650D4 380 50 4.50 3000 2450 1380 <81 WEX/WSP-700D6 380 50 2.32 1500 1100 940 <82 WEX/WSP-750D6 380 50 2.80 2200 1500 910 <78 WEX/WSP-800D6 380 50 5.40 2550 2530 940 <79 WEX/WSP-900D6 380 50 6.1 3000 2860 925 <79 INSTALLATION DETAIL WEX (Exhaust Fan) wall opening A wall opening Weather Hood Airstream Bird Screen Airstream A Steel Beam Model Wall Opening Size (mm) WSP-250D4/E4 340x340 WSP-300D4/E4 390 x 390 WSP-350D4/E4 440x440 WSP-400D4/E4 490x490 WSP-450D4/E4 540x540 WSP-500D4/E4 590x590 WSP-550D4/E4 640x640 WSP-600D4 790 x 790 WSP-650D4 835x835 WSP-700D6 880 x 880 WSP-750D6 945x945 WSP-800D6 1000 x 1000 WSP-900D6 1100 x 1100 Self tapping Screw Installation Angle Weather Hood How to mount the fan Concretewallandbrickwall • A wall opening shall be prepared according to the “WO” size of the catalog, and calked by foamed polyester to be watertight. Pre-fabricated color steel plate wall • Two horizontal beams and two vertical columns shall be equipped around the wall opening, and calked by foamed polyester to be watertight. According to jobsite situation, traingle support or threaded hanging rods are also acceptable. WSP (Supply Fan) B Weather Hood B Wall wall opening Expansion Screw Installation Angle Weather Hood Airstream Airstream Insect Screen Concrete / Brick Wall Detail 69 70 Fan Accessories and Controls THERMOSTATS MECHANICAL DESCRIPTION T15-WD The Mf-Net T15-WD mechanical thermostat has a single-pole switch-contact. When exceeding the set temperature, the thermostat switches to on or off. CONTROL DIAGRAM T15 WD On Off Set point Temperature TECHNICAL SPECIFICATIONS Temperature setting range (°C) Switch hystereis (°C) Maximum current (Ohms) Minimum load (VA) Switch Plastic housing (flame retardent) Protection class Safety approval; can be supplied with Weight, packed(kg) Dimensions of packing box (mm) w d h 72 0-40 1.5(±1)K 16A-230V 120VA(2A60V) 1 ABS IP55 CSA 0.3 100 65 155 Mf-Net Mechanical Thermostats THERMOSTATS MECHANICAL DESCRIPTION T15-2 The Mf-Net T15-2 mechanical thermostat is a combination of two single phase mechanical thermostats, which are separately adjustable. This enables the determination of the zone width, between minimum and maximum temperature. The T15-2 mechanical thermostat has two single-pole switch contacts and is extremely suitable with alarm equipment formonitoringthetemperature.TheT15-2mechanical thermostat is a preferred type for use with the MUltIFan SEAmultifunctionalstepcontroller/transformer,STW-S semi-automatic step controller/transformer (1-phase) andSTD-Ssemi-automaticstepcontroller/transformer (3-phase) or for connecting directly to a fan. CONTROL DIAGRAM T15-2 On Off Set point min. Set point max. Temperature TECHNICAL SPECIFICATIONS Temperature setting range (°C) Switch hystereis (°C) Maximum current (Ohms) Minimum load (VA) Switch Plastic housing (flame retardent) Protection class Safety approval; can be supplied with Weight, packed(kg) Dimensions of packing box (mm) w d h 0-40(2x) 1 15A-230V 120VA 2 ABS IP55 CSA 0.5 150 150 110 73 THERMOSTATS MECHANICAL DESCRIPTION T15-4 The Mf-Net T15- 4 is a mechanical multistep thermostatwithasingle-polecontactand5switching positions.Ateachriseof1°C,itswitchestothenext position. The T15-4 mechanical multistep thermostat can be used with Mf-Net SEA multifunctional step controller/transformer, STW-A fully automatic step controller/transformer (1-phase) and STD-A fully automaticstepcontroller/transformer(3-phase)orwith controls of other manufacturers. CONTROL DIAGRAM Step 5 Step 4 T15-4 Step 3 Step 2 Step 1 Set point +1 +2 +3 Temperature TECHNICAL SPECIFICATIONS Temperature setting range (°C) Switch hystereis (°C) Maximum current (Ohms) Minimum load (VA) Switch Plastic housing (flame retardent) Protection class Safety approval; can be supplied with Weight, packed (kg) Dimensions of packing box (mm) w d h 74 0-50 1 10A-250V 120VA 1 ABS IP55 CSA 0.6 150 150 110 SPEED CONTROLLER EW SERIES DESCRIPTION EW 3.15 / 6.3 The Mf-Net EW 3.15 and EW 6.3 are electronic manual fan motor speed controllers for continuously variable speed control. For the EW 6.3 the maximum output current 6.3 amps. Features •Manualspeedcontrolforcontinuouslyvariablespeed controller of single-phase fans CONTROL DIAGRAM Ventilation Output (%) 100 0 Min. Max. Manual Control TECHNICAL SPECIFICATIONS MIN. Controller type Fuse F1 (fan output) Mains supply (A) Mains frequency (Hz) Fan output voltage (V) Fan output current (A) Housing Weight, unpacked (kg.) 207 50 80 0 4or6.3 230 MAX 253 60 Vin-5 3.15or6.3 COMMENTS Manual triac FC,size5x20mm Single phase IP55plastic 0.5 120x130x90or 120x130x110 Dimensions, W x H x D (mm) Operating temperature (°C) Storage temperature (°C) Ambient relative humidity (%) TYPICAL 0 -15 Mf-Net EW Series Electronic Variable Manual Speed Controllers 40 50 95 75 REGULATOR HUMIDITY REGULATOR DESCRIPTION Humidcon-s The Mf-Net Humidcon-s can regulate the humidity in an area by activating a spray system and ventilators. The ‘on’ and cycle time of the valves in the spray system can be set accurately using the programmable timer. If no humidity sensor is connected, the ventilators contain to run and the valves in the spray system are activated continuously, in accordance with the preset ‘on’ and cycle time. If a humidity sensor has been fitted, the relative humiditycanbereadoffandset.Whenthereadingis too low, the Humidcon-s regulates the relative humidity by activating the spray valves in cycles, in accordance with the preset value. If the humidity climbs above the set value, the spray valves are disactivated and the ventilator continues to run for one hour. Characteristics •Simplehumidityregulationthankstoprogrammable timer fro spray activation •Whenusedwithhumiditysensor:automatic humidity control on the basis of preset values (relative humidity (RH), ‘on’ and cycle time •Ventilator(forrecirculation)isactivated automatically INPUTS Humidity sensor 76 SETTINGS Relative humidity set value (RH) Cycletimeforspray Mf-Net Humidcon-s Humidity Regulator OUTPUTS Ventilatoron/off Sprayvalveson/off OPERATING DIAGRAM Ventilator motor Spray valves Valve open 30 sec. t-open Switch on Humidcon-s Spray valves Time Valve closed Time t-cycle Hysteresis set at 2% Valve cycle on / off Relative humidity Valve closed Setting point TECHNICAL SPECIFICATIONS Supply voltage (V) Nominal current uptake (VA) Supply voltage frequency (Hz) Ventilator motor relay: max. flow (A) Spray valve relay: max. flow (A) Spray valve timer: Cycle time (t-cyclus) in sec. Valve open - ON time (t-open) in sec. Setting range relative humidity (%) Read-out relative humidity (%) Input signal input humidity sensor (V) Supply voltage humidity sensor (V) Housing Weight, unpacked (kg.) Dimensions, W x H x D (mm) Operating temperature (°C) Storage temperature (°C) MIN. 104 207 TYPICAL 115 230 50 0.1 0.1 MAX 126 253 10 60 5 1 0 0 5 5 120 120 98 99 0 - 10 24 155 0 -15 COMMENTS settingrange: 110V/230V at230V at230V DCat20KOhm DC,max.load200mA IP54plastic 1.4 240x200x160 40 50 77 MOTOR PROTECTION SWITCHES MBS SERIES DESCRIPTION MS4 / MS6.3 The Mf-Net MBS Series motor protection switches protect the fan motors against overloads and phase failures.Thecurrentrangeavailableis0.4-25amps. Features •Applicableason/offandlockableoperatingswitch •Testingpossibility •Modularsystem •Extendablewithmax.2auxillarycontacts,6Aeach •IP55housingavailable(MBSESMGE1) •VDE-testedandULapproved CONTROL DIAGRAM 1/L1 3/L2 5/L3 IP55 housing 2/T1 4/T2 6/T3 TECHNICAL SPECIFICATIONS ITEM CODE MBSESM4 MBSESM463 78 RATED CURRENT (A) 2.5 4 4 6.3 MAX. RATED OPERATING POWER (kW) 400/415V 500V 690V 1.5 2.2 3 2.2 3 4 Mf-Net MBS Series Motor Protection Switches OPERATING CURRENT SHORT CIRCUIT TRIP (A) 48 75.6 Bathroom Accessories STANDARD PREMIUM DRY R ANGE The Premium range offers a choice of automatic and manual hand dryers with high standards of safety. Lower working temperature makes them ideal for use in schools and nurseries, i.e. for use by children. 19224 / 19925 FEATURES • • • • • • • • • Coverwithanti-vandallock. Easier installation and maintenance. UVresistantABSplastic. ElectricallyinsulatedsplashproofIPX4. NewPrintedCircuitboard. Dust filter. Low noise. Maximum safety. Complies with EN 60335-2-23/ 1997 standards. • ApprovedbyIMQ. NEW DIMENSIONS (mm.) Premium Dry A Automatic Hand Dryer AUTOMATIC START-UP Premium Dry A Dry B C D 253 253 319 319 220 220 135 135 NEW NEW Premium Dry A automatic hand dryer Premium Dry Code 19224 19225 Hz 50/60 50/60 220-240 220-240 1,350 1,350 Voltage Watt manual hand dryer Watt (motor) 45 45 Rated current (A) 5.5 5.5 Air flow (m3h) 120 120 2.3 2.3 IPX4 IPX4 Approvals Weight (Kg) Insulation Protection IK Noise Level (at 1m) dB(A) 80 9 9 55.2 55.2 • Fitted with an infra-red sensor which starts the dryer automatically when hands enter the sensor detection field: this can be adjusted using a ”trimmer” inside the product. Premium Dry Manual Hand Dryer MANUAL START-UP • Push button protected against improper and violent use. Air delivery can be programmed to operate from 20 to 60 seconds. Supply and Install the Premium Dry or the Premium Dry A, for installation on walls, as manufactured exclusively by Vortice only for Vortice. For quick installation the unit should require only 3 screws which allow secure fixing even if wall surfaces are not even. The Premium Dry A is to be operated by an Infrared sensing device when hands are placedwithinrangeofthesensor-therangetobeadjustablebetween0and35cmby adjusting the internal trimmer. The Premium Dry to be manually operated by pressing the blackbutton.Theairdeliveryshouldbeprogrammabletooperatefrom20to60seconds. ItshouldbetestedandcertifiedasIPX4(splashproof)withallperformancedatathird party IMQ (BEAB recognized equivalent) verified. The product should comply with EN60335-2-23/1997partII“Specialregulationsforhairandskincareappliances”. Thedryershouldbemanufacturedfromanti-UVABSplastic,withalockablecover(key provided). The motor should be a thermally protected induction motor with an overheat safety thermostat and include a thermal cut out device. In addition, the heating element should automatically cut out when the button or infrared beam system is blocked, either voluntarilyininvoluntarily,orifthenozzleisblocked.Adustfiltershouldbeintegralto theunit.Thedryershouldhavea1.35kWheatingelementandairflowdeliveryinfree airof33.3l/s,thelowerworkingtemperaturemakingtheunitsidealforusebychildren. A system of flow feeders inside the delivery nozzles should distribute the air evenly. Thedecibelratingshouldbenomorethan55.2dB(A)at1meter. VORTICE Premium Dry Range Manual & Automatic Hand Dryers CLASSICS OPTIMAL DRY R ANGE The Optimal Dry range provides automatic and manual hand dryers with a hard-wearing and attractively designed plastic casing, which makes them suitable for use in prestigious buildings. The printed circuit boards have been specifically designed and tested to guarantee long-term operation. 19229 / 19926 FEATURES • • • • • • • • Easier installation and maintenance. UVresistantABSplastic. ElectricallyinsulatedsplashproofIPX4. NewPrintedCircuitboard. Dust filter. Low noise. Maximum safety. Complies with EN 60335-2-23/ 1997 standards. • ApprovedbyIMQ. NEW Optimal Dry A DIMENSIONS (mm.) Optimal Dry Automatic Hand Dryer Manual Hand Dryer AUTOMATIC START-UP • Fitted with an infra-red sensor which starts the dryer automatically when hands enter the sensor detection field: this can be adjusted using a ”trimmer” inside the product. Optimal Dry A Dry B C D 253 253 319 319 220 220 135 135 NEW NEW Optima Dry A automatic hand dryer Optimal Dry Code 19229 19226 Hz 50/60 50/60 220-240 220-240 Voltage Watt manual hand dryer 2,000 2,000 Watt (motor) 65 65 Rated current (A) 9 9 170 170 2.6 2.6 IPX4 IPX4 Air flow (m3h) Approvals Weight (Kg) Insulation Protection IK Noise Level (at 1m) dB(A) 9 9 61.4 61.4 MANUAL START-UP • This is activated by pressing the button, which is protected against improper and violent use. The air can be programmed tooperatefrom20to60seconds. Only 3 fixing screws. Clip arrangement allows simple installation and fixing of the motor assembly within the back plate. The front cover is locked by a single socket-head screw, allen-key included. Supply and Install the Optimal Dry or the Optimal Dry A, for installation on walls, as manufactured exclusively by Vortice only for Vortice. For quick installation the unit should require only 3 screws which allow secure fixing even if wall surfaces are not even. The Optimal Dry A to be operated by an Infrared sensing device when hands are placed withinrangeofthesensor-therangetobeadjustablebetween0and35cmbyadjusting the internal trimmer. The Optimal Dry to be manually operated by pressing the black button.Theairdeliveryshouldbeprogrammabletooperatefrom20to60seconds. ItshouldbetestedandcertifiedasIPX4(splashproof)withallperformancedatathird partyIMQ(BEABrecognizedequivalent)verified.Theproductshouldcomplywith EN60335-2-23/1997partII“Specialregulationsforhairandskincareappliances”. Thedryershouldbemanufacturedfromanti-UVABSplastic,withalockablecover(key provided). The motor should be a thermally protected induction motor with an overheat, safety thermostat and include a thermal cut out device. In addition, the heating element should automatically cutout when the button or infrared beam system is blocked, either voluntarilyininvoluntarily,orifthenozzleisblocked.Adustfiltershouldbeintegraltothe unit.Asystemofflowfeedersinsidethedeliverynozzlesshoulddistributetheairevenly. Thedryershouldhavea2kWheatingelement,andairflowdeliveryinfreeairof47.2l/s andadecibelratingofnomorethan61.4dB(A)at1meter. VORTICE Optimal Dry Range Manual & Automatic Hand Dryers 81 ANTI-VANDAL METAL DRY R ANGE Metal Dry range is particularly suitable to high usage. Installation in public premises such as shopping centers, motorway services and fast food outlets. The metal outer casing and air nozzle guarantees perfect long-term ef ficiency and aesthetics. The Metal Dry Range leaves tradition behind, offering a design that is both linear and unique. FEATURES • Die- cast aluminum cover with anti-vandal lock. • Easy installation and maintenance. • Nozzlecanbeturned360°. • ElectricallyinsulatedsplashproofIPX4. • NewPrintedCircuitboard. • Maximum safety. • Scratch-resistant paint. • Automatic switch-off. •Rapid dr ying with low power consumption. • Appliances manufactured in compliance withEN60335-2-23/1997. • ApprovedbyIMQ. Metal Dry A Dry B C D 280 280 355 355 202 202 139 139 Metal Dry A Metal Dry automatic manual vandal-resistant vandal-resistant hand dryer hand dryer Code 19220 Hz 50/60 50/60 220-240 220-240 Voltage Watt 19221 1,950 1,950 Watt (motor) 140 140 Rated current (A) 8.5 8.5 Air flow (m3h) 190 190 6.9 7.0 IPX4 IPX4 Approvals Weight (Kg) Insulation Protection IK Noise Level (at 1m) dB(A) 82 Metal Dry A 10 10 69.8 69.8 Metal Dry Automatic Vandal-resistant Hand Dryer AUTOMATIC START-UP • Fitted with an infra-red sensor which starts the dryer automatically when hands enter the sensor detection field: this can be adjusted using a ”trimmer” inside the product. DIMENSIONS (mm.) 19220 / 19921 Manual Vandal-resistant Hand Dryer MANUAL START-UP • This is activated by pressing the button, which is protected against improper and violent use. Air delivery can be programmed to operate from 20 to 60 seconds. Thanks to their solid aluminium frame and anti-graffiti paint, they are vandal-proof. The manual version (Metal Dry) can be started by pressing the button. The hot air flow can be adjusted within a range of 20 to 60 seconds by means of an internal setting. The automatic version (Metal Dry Automatic) has an infrared device that starts the hand-dryer automatically every time the hands of the user come within the operating range of the sensors. Nozzle can be turned 360°. The Vortice Metal Dry Automatic/Manual Hand Dryer is constructed with a solid steel frame, and die cast aluminium front cover painted in anti-graffiti paint, making it an extremely robust unit suitable for public areas. In addition the unit has a vandal resistant bolted lock. The unit incorporates a motor with ball bearings and thermal cut-out, and isIPX4rated.Themanualversionisstartedbypressingthebutton,andthehotairflow canbeadjustedwithinarangeof20to60seconds.Theautomaticunitincorporatesan infrared sensor, which activates the unit when hands are brought to within the operating range of the sensors. VORTICE Metal Dry Range Manual & Automatic Vandal-resistant Hand Dryers