SPORTS FLOORINGS

Transcription

SPORTS FLOORINGS
SPORTS FLOORINGS
2014-2015
www.kenncoat.com
“Success with experience, product with quality.”
3-4
ABOUT US
5-8
KENNCOAT POLYURETHANE - INDOOR
KENNCOAT POLYURETHANE - OUTDOOR
9-12
13-14
15-17
KENNCOAT BINDER
KENNCOAT ACRYLIC
18-20
KENNCOAT INSULATION
REFERENCES
21
ABOUT US
Pehlivan Kimya A.Ş. has been commercially active since 2003 in the
field of construction and sports industry. Turnkey floor projects required
for sports premises are designed and manufactured by our Company.
Our company successfully implements the manufacturing and
installation of any kind of sportive premises equipment including primer
to final coat, volleyball and tennis grounds for sports premises where
our children and youngsters might get a chance to improve themselves.
Our company has underlined a successful and quality manufacturing
and rendered itself exporting half of its production to international
market. Polyurethane and acrylic coating materials with various
applications are served to numerous companies in Anatolia in raw
material form. Our company has been gradually improving itself with
every single day on a professional level in the field of sport and
ındustrial coatings and dedicates itself to provide the best quality
production to its clients. Pehlivan Kimya has developed a remarkable
expertise on tartan tracks, jogging courses, synthetic pitches, acrylic
floor coating and furthermore, work on alternative manufacturing
methods like polyurethane materials of which no production yet exists
in Turkey. At present, our own product, dual component polyurethane
based synthetic pitch glue is used in Turkic Republics, Middle East and
throughout Turkey.
As a conclusion, we will have venture initiations in Europe and other countries for
the widened use of our products. Pehlivan Kimya is capable of manufacturing
shock-pad glue required for indoor sports halls, upper layer sealer and self-levelling
polyurethane materials and is in the aim of permanently sustaining its principles of
quality and honest service approach. We will be pleased to serve you with our
young and dynamic team.
www.kenncoat.com
3
ABOUT US
LABORATORY
Our research development and quality control studies contiue at our R&D laboratory.
www.kenncoat.com
4
KENNCOAT POLYURETHANE
TECHNICAL DATA
Colour : Natural, green, several colours
Mixing mass density : 1.52 kg/l
Mixing ratio(mass) : 5/1
Theoretical consumption rate : 1kg/m2 (for 0.90-1.10 kg / m2)
All curing period : 6-8 hours (25°C)
Heat Resistance : Approx. 100°C (for cured product)
Shore A : 85 ±5
Application time : 15-30 minutes (Depends on temperature and humidity)
ADHESIVE
Kenncoat Polyurethane Adhesive is two component, solvent free,
polyurethane adhesive. Use as an adhesive to fix rubber and joining the
synthetic grass carpet.
APPLICATION CONDITIONS
Surface must be clean, dry, free from grease and oil.
APPLICATION PROCEDURE
Mix 5 kgs of Component A and 1 kg Component B for two minutes with a low speed
electric
mixing paddle.
It is important that two components mixed homogeneously
Mix only that amount of material can be used in 15-30 minutes. (Depends on air
temperature)
Trowell should be used.
Application temperature is 10°C - 30°C
The surface must be protect from water for 8-10 hours.
SHELF LIFE
Shelf life is 12 months from the production date in appropiate conditions.
STORAGE
The product must be stored in sealed containers at 15-25°C
SAFETY DATA
Use protective goggles and gloves.
Avoid contact with skin and eyes.
Keep away from children.
In case of skin contact, wash skin thoroughly with soap and plenty of water.
All equipment should be cleaned after thinner, butyl acetate or ethyl acetate.
PACKAGING
Component A: 21 kg metal
Component B: 4 kg metal
www.kenncoat.com
5
KENNCOAT POLYURETHANE
SEALER
TECHNICAL DATA
Colour : Grey, white and multiple colors
Mixing mass density : 1.38 kg/l
Mixing ratio(mass) : 5/1
Theoretical consumption rate:
1)Rolled rubber pad : 1.Layer 760 gr/m2 2.level 200 gr/ m2
2)Cast rubber applications : 1.level 1460 gr/m2 2.level 160-200 gr/ m2
Note : Consumption rate depends on the roller rubber pad and the diameter
of the rubber granules.
Curing period : 6-8 hours (25°C)
Heat Resistance : Approx. 100°C (for cured product)
Shore A : 75 ±5
Application temperature : 10-25°C
Application time : 15-30 minutes (Depends on temperature and humidity)
Kenncoat Polyurethane Sealer is two component, solvent free,
polyurethane sealer. Use as a pore filler on rubber pad and casting
rubber appplications.
APPLICATION CONDITIONS
Surface must be clean, dry, free from grease and oil.
Surface should be free from moisture.
APPLICATION PROCEDURE
Mix 5 kgs of Component A and 1 kg Component B for two minutes with a low speed electric
mixing paddle. It is important that two components mixed thoroughly. This mixture should
be used in one application period(10-25 minutes). (Depends on air temperature). Metal or
plastic squeegee should be used. The surface must protect from water for 8-10 hours.
SHELF LIFE
Shelf life is 12 months from the production date in appropiate conditions.
STORAGE
The product must be stored in sealed containers at 15-25°C
Clean-up:All equipment should be cleaned with thinner, butyl acetate or ethyl acetate.
SAFETY DATA
Use protective goggles and gloves. Avoid contact with skin and eyes. Keep away from
children. In case of skin contact, wash skin thoroughly with soap and plenty of water.
PACKAGING
21 kgs tin Component A
4 kgs tin Component B
www.kenncoat.com
6
SELF-LEVELLING
KENNCOAT POLYURETHANE
TECHNICAL DATA
Colour : Several colours.
Mixing mass density : 1.34 kg/l
Mixing ratio(mass) : 4/1
Theoretical consumption rate : 1.2 kg/m2 ( for 1 mm)
All curing period : 6-8 hours (25°C)
Heat Resistance : Approx. 100°C (for cured product)
Shore A : 70 ±5
Application time : 5-15 minutes (Depends on temperature and humidity)
Kenncoat Polyurethane Sef-Levelling is two component self-levelling
coating material. Use as a coating to have the elastic effect of fitness and
sports areas.
APPLICATION PROCEDURE
Surface must be clean, dry, free from grease. Mix 4 kgs of Component A and
1 kg Component B for two minutes with a low speed electric mixing paddle. It
is important that two components mixed thoroughly. This mixture should be
used in one application period (5-15 minutes). (Depends on air temperature)
Squeegee or trowel should be used. Application temperature is 10°C - 30°C
SHELF LIFE
Shelf life is 12 months from the production date in appropiate conditions.
STORAGE
The product must be stored in sealed containers at 15-25°C.
Clean-up: All equipment should be cleaned after thinner, butyl acetate or ethyl
acetate.
SAFETY DATA
Use protective goggles and gloves. Avoid contact with skin and eyes. Keep
away from children. In case of skin contact, wash skin thoroughly with soap
and plenty of water.
PACKAGING
16 kgs tin Component A
4 kgs tin Component B
www.kenncoat.com
7
KENNCOAT POLYURETHANE
Kenncoat Topcoat is two component polyurethane resin based
elastic topcoat. Kenncoat Topcoat is used at sports/concerts
halls under great circulation by the help of resistance against to
chemicals and air conditions. Kenncoat Topcoat protects its
color and brightness perfectly.
TOP COAT
TECHNICAL DATA
Color : Several colors
Density : 1.20 kg/l (mix)
Solid matter by volume : 56 ± 1 (ASTM D 2697-3)
V.O.C : 352 g / L ( ASTM D 3960-05)
Dry film thickness : For one layer 40-80 μm
Theoretical Consumption Area : 11.60 m2 / kg (50 μm DFT)
Touch after dry : 5 hours (20 °C)
Full cure : After 7 days (20 °C)
Curing time depends on the air temperature, film thickness, air and environmental
conditions. When the temperature is low, curing time increases.
APPLICATION CONDITIONS
Surface must be clean, dry, free from grease. In a dirty environment for a long time, the
surface must be cleaned with water and allowed to dry and a second layer should be applied
after the surface has dried thoroughly. To prevent the moisture in the air condense, the
surface temperature should be 3°C greater than dew point.
APPLICATION PROCEDURE
Kenncoat Topcoat protection system mixing ratio by volume: 2,5 parts A and 1 part B. It is
recommended that the following rules should be followed during application. Equipment
should be cleaned with a suitable thinner before application. A component mixed separately
then the mixture of A and B components must be mixed for 5 minutes. Paint should not be
diluted more than %10. For homogenous of the paint, mix several times during application.
Indoor aplications, good ventilation should be ensured. After application, the equipment
should be clean with thinner.
SHELF LIFE
4-50°C, in its original packaging, shelf life is one year.
SAFETY DATA
Comply the regulations of flammable liquids. Take safety precautions on the product label.
Keep in a cool,dry and well ventilated area. Keep away from children. Do not breathe, avoid
contact with skin and eyes.
PACKAGE
A component 9 kgs
B component 3 kgs
www.kenncoat.com
8
KENNCOAT POLYURETHANE
SANDWICH SYSTEM
Primer : 150-160 gr/m2 1100 cp
Granular rubber : 1-3,5 mm 1250 gr/2 mm
Binder : 20% of total granule weight, 1,08 gr/cm3
Sealer : 1460 gr/m2 %10-30 thixotropic with EPDM powder
Self levelling : Two-component 1,20 gr/cm3
Brick red : 1-3,5 mm EPDM 3,2 kg/m2
Dust, oil and foreign substances must be removed from
surface. On this clean surface, primer must be applied.
Poliurethane binder and 1-3,5 mm granules are mixed in
mixer and then applied on surface with 10 mm thickness by
finischer. After this two-component thixotropic sealer is laid
on elastic layer. In this way, this system has become
waterproof. And finally, Polyurethane self levelling is applied.
At this stage, 1-3,5 mm Red EPDM granules are applied on
this layer by broadcasting system. Excess quantity of spread
granules are removed and lines are set.
www.kenncoat.com
9
KENNCOAT POLYURETHANE
FULL SYSTEM
Primer:150-160 gr/m2 1100 cp
1st layer: Self levelling 3000-3500 gr/m2 and 2500-3000 gr/m2 black granule
2nd layer: Self levelling 3000-3500 gr/m2 and 2500-3000 gr/m2 black granule
3nd layer: Self levelling 3000-3500 gr/m2 and 3000-3200 gr/m2 coloured EPDM
Dust, oil and foreign substances must be removed from surface.
On this clean surface primer must be applied, after primer,
polyurethane self levelling is applied and SBR or EPDM granules
spread on layer. After surface drying, excess quantity of granules
is removed from surface. Whole application is checked, In case of
any default, it is repaired and 2nd layer application is started.
First layer application is repeated at this step. Excess quantity of
granules is removed from surface. For last layer, polyurethane self
levelling is applied and then coloured EPDM granules are spread.
Excess quantity of EPDM granules is removed and running track
application is completed.
www.kenncoat.com
10
SPRAY SYSTEM
KENNCOAT POLYURETHANE
Primer: 150-160 gr/m2 1100 cp
SBR or EPDM: Black granule 6250 gr/m2 for 10 mm, (Approximate
consumption amount for smooth surface)
Primer application-repeat: 110-120 gr/m2
1100 cp 0,5-1,50 mm coloured EPDM 800-100 gr/m2
Two-component self-levelling: 1200-1400/ gr/m2 ; 1,20 gr/cm3
Dust, oil and foreign substances must be removed from
surface. On this clean surface primer must be applied. After
primer, 1-3,5 mm black SBR or EPDM granules mixed with
polyurethane binder are laid on 10 mm thickness with
finischer. On this elastic layer, primer application is repeated
and finally, 0,5-1,5 mm coloured EPDM granules mixed with
two-component polyurethane self levelling are sprayed on
surface.
www.kenncoat.com
11
KENNCOAT POLYURETHANE
STANDARD SYSTEM
Primer: 150-160 gr/m2 1100 cp
8 mm black granule coat:5 kg/m2 theoretically proper surface
primer 110-120 gr/m2 1100 cp
7 mm coloured EPDM coat: 1-3,00 mm 4kg/m2 theoratically
Dust, oil and foreign substances must be removed from
surface. On this clean surface, primer must be applied.
After primer 1-3,5 mm black SBR or black EPDM granules
mixed with polyurethane binder are laid on surface with 8
mm thickness by finischer. On this elastic layer, primer
pplication is repeated and standard system EPDM coating
is completed by laying 7 mm thickness of coloured EPDM
granules.
www.kenncoat.com
12
KENNCOAT POLYURETHANE
INSUTU BINDER
Kenncoat Binder is one-component, polyurethane based, isocyanate
prepolymer. Kenncoat Binder is used as insitu binder at sports fields and
children playgrounds.
TECHNICAL DATA
Colour: Light yellow
Density: 1,1 gr / cm3
Viskocity: 3000-3500 cps
NCO: 9,5-10,5%
APPLICATION PROCEDURE
Kenncoat Insıtu Binder is mixed with EPDM or SBR
granules as 20% ratio and
laid by finischer.
SHELF LIFE
Shelf life is 6 months from production date at 15-45 °C
temperature and appropriate
conditions.
PACKAGING
200 kg metal barrels.
www.kenncoat.com
13
KENNCOAT POLYURETHANE
PRESS BINDER
Kenncoat Binder is one-component, polyurethane based, isocyanate
prepolymer. Kenncoat Press Binder is used for sports fields and children
playgrounds projects, and in manufacturing rubber tiles.
TECHNICAL DATA
Colour : Yellow
Density : 1,1 gr/cm3
Viskocity : 4500-5500 cps
NCO : % 9,5-10,5
APPLICATION PROCEDURE
Kenncoat Press Binder is mixed with EPDM or SBR
granules with 5-6% ratio
and pouring into a mould.
SHELF LIFE
Shelf life is 6 months from production date at 15-45 °C
temperature and appropriate
conditions.
PACKAGING
200 kg metal barrels
www.kenncoat.com
14
RESURFACER
KENNCOAT ACRYLIC
Kenncoat Resurfacer is water-based acrylic binder, apply with
mixing the silica sand and its used for the concrete and asphalt
bases for adherence the upper layers, pores filling and make the
smooth surfaces.
TECHNICAL DATA
Product : Kenncoat Resurfacer
Binder : Acrylic
Drying time : 1 hour (25oC), 2-6 hours wait for apply the second layer,
it should be observed that the surface completely dry.
Color : Black
Theoretical consumption rate : Kenncoat Resurfacer theoretical consumption
rate is 400-750 gr/m2
SURFACE PREPARATION
Dust, oil, foreign substances must be removed from the surface. The
temperature of the surface must be between 10oC - 35oC. Kenncoat
Resurfacer is applied between the temperature 10oC and 35°C. Min. 14 days
for new asphalt surfaces and min. 22 days for new concrete sufaces should
be waited before an application. Repairing fine cracks and surface defects,
use a mixing of pure acrylic binder, cement and silica sand. One day after
repair, Kenncoat Resurfacer should be applied. It is recommended that
Kenncoat Resurfacer is applied after the epoxy or polyurethane primer coating
on concrete surfaces.
MIXING RATIO
Kenncoat Resurfacer, %50-%60 silica sand, %30-%40 water
*It changes depending on the asphalt surface and application temperature.
APPLICATION AND CLEANING EQUIPMENT
Kenncoat Resurfacer is applied with squeegee. Clean tools and equipment
with water, after use.
PACKAGING AND STORAGE
Kenncoat Resurfacer is available in 65 kg plastic drums, should be stored at
room temperature. Acrylic binder is deteriorated above 40oC and below 10oC.
Shelf life is 1 year from production date at room temperature and appropriate
conditions. Material must be protected from freezing.
SAFETY DATA
In case of contact with skin please wash the skin clearly.
www.kenncoat.com
15
CUSHION
KENNCOAT ACRYLIC
TECHNICAL DATA
Product : Kenncoat Cushion
Binder : % 100 Acrylic
Drying time : 1 hour at 25oC, 2-6 hours wait for apply the second layer
(It should be observed that the surface completely dry.)
Color : Grey
Theoretical consumption rate:
Kenncoat Cushion theoretical consumption rate is 350-500 gr/m2’dir.
Kenncoat Cushion is water-based acrylic binder, prepared with 0.5 mm1.0 mm or 1.0-2.0 mm of rubber granules. This material used for flexibility
of the surface.
SURFACE PREPARATION
Dust, oil, foreign substances must be removed from the surface. The
temperature of the surface must be between 10oC – 35oC.
APPLICATION AND CLEANING EQUIPMENT
Kenncoat Cushion is applied with squeegee.
Clean tools and equipment with water after use.
PACKAGING AND STORAGE
Kenncoat Cushion is available in 60 kgs plastic barrels, should be
stored at room temperature. Acrylic binder is deteriorated above 40oC
and below 10oC. Shelf life is 1 year from production date at room
temperature and appropriate conditions. Material must be protected
from freezing.
SAFETY DATA
In terms of skin contact, wash skin clearly.
www.kenncoat.com
16
TOP COAT
KENNCOAT ACRYLIC
TECHNICAL DATA
Product : Kenncoat Topcoat
Binder : Acrylic
Drying time : 1 hour at 25oC, 2-6 hours wait for apply the second layer it
should be observed that the surface completely dry.
Color : RAL colors
Kenncoat Topcoat theoretical consumption rate:
Kenncoat Topcoat 2nd layer (500-650 gr/m2) %50-%60 sand %30 water
Kenncoat Topcoat layer (250-350 gr/m2) %5-%10 sand %40 water
Kenncoat Topcoat is %100 acrylic binder, water-based, high UV resistance
tennis court paint.
MIXING RATIO
Kenncoat topcoat 1st layer: %50-%60 silica-sand, %20-%30 water
Kenncoat topcoat 2nd layer: %5-%10 silica-sand, %30-%40 water
For 3rd layer: only mix %10-%25 water
SURFACE PREPARATION
Dust, oil,foreign substances must be removed from the surface. The
temperature of the surface must be between 10oC – 35oC.
APPLICATION AND CLEANING EQUIPMENT
Kenncoat Topcoat is applied with squeegee.
Clean tools and equipment with water after use.
PACKAGING AND STORAGE
Kenncoat Topcoat is available in 70 kgs plastic barrels, should be stored at
room temperature. Acrylic binder is deteriorated above 40oC and below
10oC. Shelf life is 1 year from production date at room temperature and
appropriate conditions. Material must be protected from freezing.
SAFETY DATA
In terms of skin contact wash skin clearly.
www.kenncoat.com
17
ONE COMPONENT PRIMER
KENNCOAT INSULATION
Kenncoat One Component Primer is one component, solvent-free
polyurethane based primer. Kenncoat One Component Primer is used for
water insulation at roof, terrace, garage and balcony. Besides this it is
used as primer on concrete surfaces.
TECHNICAL DATA
Color : Light yellow, blue, green, grey
Density : 1.17 kg/l
Theoretical consumption rate : 100-150 gr/m2
Curing time : 3-6 hours (20oC)
SURFACE PREPARATION
Dust, oil, foreign substances must be removed from the surface. The
temperature of the surface must be between 15oC – 25oC.
APPLICATION AND CLEANING EQUIPMENT
Pot Life: 15-30 minutes (Depends on temperature and humidity)
Equipment: Roller should be used. Tools can be clean with ethyl acetate,
butyl acetate and thinner. Do not use below 10oC.
SAFETY DATA
Use protective goggles and gloves. Avoid contact with skin and eyes.
Keep away from children. In case of skin contact, wash skin thoroughly with
soap and plenty of water.
PACKAGING AND STORAGE
Kenncoat One Component Primer is available 20 kg tin drums, 200 kg metal
barrels at 15oC – 25oC for one year from the production date.
www.kenncoat.com
18
TWO COMPONENT PRIMER
KENNCOAT INSULATION
TECHNICAL DATA
Color : Light yellow, blue, green, grey
Density : 1.03 kg /l
Theoretical consumption rate : 100-150 gr/m2
Curing time : 3-6 hours (20oC)
Kenncoat Two Components Primer is double component, solvent
free, polyurethane based primer. Kenncoat Two Components
Primer is used for water insulation at roof, terrace, garage and
balconies. Behind this it is used as primer on concrete surface.
SURFACE PREPARATION
Dust, oil,foreign substances must be removed from the surface. The
temperature
of the surface must be between 15oC – 25oC.
APPLICATION AND CLEANING EQUIPMENT
Mixing ratio (mass): 12 kgs A + 4 kgs B
Pot Life: 15-30 minutes (Depends on temperature and humidity)
Equipment: Roller should be used.
Tools can be clean with ethyl acetate, butyl acetate and thinner.
Do not use below 10oC.
PACKAGING AND STORAGE
Kenncoat One Component Primer is available 20 kg tin drums, 200 kg metal
barrels at 15oC – 25oC for one year from the production date.
SAFETY DATA
Use protective goggles and gloves. Avoid contact with skin and eyes.
Keep away from children. In case of skin contact, wash skin thoroughly with
soap and plenty of water.
www.kenncoat.com
19
KENNCOAT INSULATION
INSULATION SYSTEM
Kencoat Insulation System is applied on concrete surface in order to provide water insulation. Before application; oil, dust and foreign
substances must be removed from surface. For first layer Kenncoat Polyurethane Primer is applied (100-150 gr/m2) After primer totally
dried (6 hours) Kenncoat Polyurethane Self Levelling is applied (1-2kg/m2). If required, silica sand spread over the layer in order to
provide durability. After self levelling completely dry, Kenncoat Top coat is applied (app.100-150g/m2). Kenncoat Insulation System
provides water insulation with the resistance against to UV, chemicals and erosion especially at car parks and terraces.
www.kenncoat.com
20
KENNCOAT
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
ADACAN İNŞAAT
AKDAĞMADENİ BELEDİYE BAŞKANLIĞI
AKDAM İNŞAAT
AKSA PEYZAJ
ALP İNŞAAT KÜTAHYA DUMLUPINAR ÜNİVERSİTESİ
ALTERNATİF A.Ş
ANADOLU MESLEK LİSESİ YENİMAHALLE
ANK. ATATÜRK LİSESİ BASKETBOL VE FUTBOL SAHALARI, ATAK TİC.
ANKARA BÜYÜKŞEHİR BELEDİYESİ, 14 ADET KÖY PARKI ÇEVRE ÇİTİ
ANKAS İNŞAAT
ATAK TİCARET K. IRAK SÜLEYMANİYE
ATAK TİCARET ZONGULDAK ÜNİVERSİTESİ
ATAPARK ŞEHİTLER PARKI FUTBOL SAHASI
AYGAZ A.Ş.
B.B ANKARA SPOR AKTEPE STADI
BADEMLİK MAH. BASKET VE FUTBOL
BATIKENT DEMİRYOLCULAR SİTESİ
BİLİM KOLEJİ 100. YIL
BUKE FIRAT ZEMİN KAPLAMALARIT
CEMRE SPOR
ÇALIŞMA BAKANLIĞI ATAK TİCARET
ÇANKAYA BELEDİYESİ YILDIZ MAH. FUTBOL SAHALARI
ÇAYYOLU Ç. EMEK SİTESİ TENİS KORTU
ÇELİK İNŞAAT RİZE
DEMİRSPOR BEHİÇBEY SAHALARI
DENİZ KUVVETLERİ KOMUTANLIĞI TENİS KORTU
DORE İNŞAAT ASYA FİNANS KIZIL CAHAMAM SPOR SAHALARI
DURMAZ İNŞAAT
EMİN KURT İNŞAAT İSTANBUL
ERDEM MÜHENDİSLİK
ERGİN SPOR SANAYİİ
ESKRİM FEDERASYONU
ETİMESGUT BELEDİYESİ
ETİMESGUT BELEDİYESİ PARKLARI 22 ADET
EYNEHAN İNŞAAT MSB SİLAHLI KUVVETLER SPOR OKULUSAHALARI
EY-TUR EĞİMİM PROJE LTD ŞTİ
FATİH STADI ÇEVRE FENS TELİ
FBK YAPI
FTŞ İNŞAAT MÜHENDİSLİK
GALATASARAY SPOR TES. FUTBOL, TENİS VE BASKETBOL SAHALARI
GAZİ ÜNİVERSİTESİ GÖLBAŞI TESİSLERİ
GENÇLERBİRLİĞİ VE ANKARAGÜCÜ ORTAK GİRİŞİMİ 19 MAYIS STADI
REFERENCES
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
GENÇLİK SPOR İL MÜDÜRLÜĞÜ ANKARA
GENÇLİK SPOR İL MÜDÜRLÜĞÜ ARTVİN
GENÇLİK SPOR İL MÜDÜRLÜĞÜ ŞANLIURFA
GENÇLİK SPOR İL MÜDÜRLÜĞÜ TRABZON
GİRESUN GENÇLİK SPOR İL MÜDÜRLÜĞÜ
GÖKTÜRK PARKI SAHASI
HATKO TEKSTİL TÜRKMENİSTAN HALI SAHA VE TENİS KORTU YAPIMI
HAYRETTİN ŞATIROĞLU RİZE
HEDEF ÇİM
HST TEKSTİL SANAYİİ
İMAY İNŞAAT
İNTERSEL İNŞ.
İNTERSEL LTD. ŞTİ
İSTANBUL BAĞCILAR BELEDİYESİ
K.H.O. PENTATLON SAHASI
KALE KAUÇUK
KAMİL OCAK BASKET SAHASI
KARA HARP OKULU
KAZAN BELEDİYE BAŞKANLIĞI
KAZANKAYA BELEDİYESİ YOZGAT PANEL ÇİT
KEÇİÖREN AKTEPE 2 ADET FUTBOL VE 1 ADET BASKETBOL
KEÇİÖREN BELEDİYESİ
KETU İNŞAAT
KONYA İL STADI SENTETİK ZEMİN KAPLAMASI
KUŞCAĞIZ FUTBOL SAHASI
MDA SPOR BATIKENT METRO SAHALARI
MEGA A.Ş. ANTALYA
MEGA A.Ş. PRENCES HOTEL BODRUM
MEGA PAZARLAMA İSTANBUL
MESCİOĞLU İNŞAAT
MİLTAŞ İNŞAAT
MUTA İNŞAAT
NORM İNŞAAT ANTALYA
OKYANUS GRUP YALITIM ÇÖZÜMLERİ, İSTANBUL
ORCAN SPOR ALANYA TENİS KORTU
OSMANİYE İL STADI
ÖNÇİT
ÖZDEKAN KAUÇUK SANAYİİ
ÖZERK İNŞAAT ANTALYA
ÖZGÜR MÜHENDİSLİK
ÖZKONAKLI İNŞAAT
PARK HOLDİNG SENTETİK GOLF PİSTİ
www.kenncoat.com
21
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
PEBA TEKSTİL
POLİN İNŞAAT BODRUM
POLİS AKADEMİSİ MALTEPE MDA
PURSAKLAR BELEDİYE BAŞKANLIĞI
PYS İNŞAAT LTD.
ROBİNSON CLUP ERKLER İNŞAAT
S.B.E. KOŞU PİSTİ
SAYGINLAR İNŞAAT
SEA GARDEN HOTEL BODRUM
SER İNŞAAT
SİLAHLI KUVVETLER SPOR OKULU
SÜLEYMAN KURT SİVAS
ŞEHİT KUBİLAY PARKI
TEKNİK GÜÇ BİRLİĞİ YAPI KOOPERATİFİ BALIKESİR
TEMPO TEL ÇİT
TEMPO TİCARET AHMET EKER
UĞURSEL LTD.
ULUSOY ELEKTRİK
WATERLAND TOURISM
YALOVA BELEDİYESİ
YARSH-HUMA İNŞ.
YENİMAHALLE BELEDİYESİ CEMRE PARKI BASKETBOL SAHASI
ZE-YE İNŞAAT
ZİRAAT BANKASI SOSYAL TESİSLERİ YENİMAHALLE
ZİYA-ÜL HAK FUTBOL SAHASI
REFORM SPOR SİSTEMLERİ LTD. ŞTİ.
İLKE YAPI MAKİNE MEHMET YILMAZ
ŞEREFLİKOÇHİSAR BELEDİYE BAŞKANLIĞI
TÜRKİYE FUTBOL FEDERASYONU
TÜRK TRAKTÖR VE ZİRAAT MAKİNELERİ A.Ş.
ÇANKAYA BELEDİYE BAŞKANLIĞI
ÇANKAYA İMAR PROJE İNŞ. MAD. SAN TİC. A.Ş.
KOZ-KENT SPOR ZEMİNLERİ
PRO-SPORT İNŞ. TAAH. SPOR MAL İTH. İHR. A.Ş.
SUSUZ BAHÇE SPORT PEYZAJ SAN. LTD. ŞTİ.
T.S.K. SPOR OKULU VE EĞİTİM MERK. KOM.
T.C. CUMHURBAŞKANLIĞI TEKNİK İŞLER MÜD.
TAVŞANLI BELEDİYESİ
SİNCAN BELEDİYE BAŞKANLIĞI
POLATLI BELEDİYE BAŞKANLIĞI
rgü
Ö
Tel ire
zli
W
ani ized
v
l
Ga alvan
G
Spor
Sahaları
Sports
Pitches
ı
has
s
l Sa
bo Pitche
t
e
ll
sk
Ba ketba
Bas
ı
has
l Sa ches
o
b
it
Fut tball P
Foo
Tel Örgü
Çeşitleri
Wire Mesh
Pvc
K
Pvc aplı T
e
Co
ate l Örg
dW
ü
ire
Vole
Volle ybol S
a
yba
ll Pit hası
che
s
Ten
i
Ten s Saha
nis P
s
itche ı
s
ça
Fır h
s
Bru
Saha Bakım
Ekipmanları
Maintanence
Equipments
Ball
Top
Yu
Roll ve T varla
Ramırmı ma
p, Dk
rag
ma
t
www.kenncoat.com
22
n
eta sı
e
ı
liür
Po ıştırıc hesiv
d
Yap ane A
th
ure
Poly
in
Zem
rilik c
Ak Acryli
cun
Ma ler
Sea
Poliüretan
Polyurethane
Self
Lev
ellin
g
Tart
a
Run n Pist
le
ning
Truc r
k
aro
k K ber
uçu ub
Ka ed R
uld
Mo
www.kenncoat.com
23
Hal
Yap ı Saha
ı
Pitc ştırıcıs
hes
ı
Glue
Kau
ç
Rub uk Rulo
ber
Mat
İvedik Organize Sanayi Bölgesi
Melih Gökçek Blv. 1485. Cd.
1363. Sk. No: 78-79-81
Yenimahalle/ANKARA-TÜRKİYE
T:+90 312 395 10 34 - 35
info@kenncoat.com
www.kenncoat.com

Similar documents

Resmî Gazete - Resmi Gazete

Resmî Gazete - Resmi Gazete 2. L'acte a remettre doit être rédigé soit dans l a langue de l a Partie requise, soit accompagné de deux copies de sa traduction dans cette langue. L a traduction doit être certifiée exacte par l'...

More information

TC Resmî Gazete

TC Resmî Gazete Recep Tayyip ERDOĞAN Başbakan T.C. CUMHURBAŞKANLIĞI

More information