ModelMCV - Goldberg Systems GmbH
Transcription
ModelMCV - Goldberg Systems GmbH
innovation in energy MCV Model innovation in energy EV/HEV Battery Cell Testing System FEATURES & BENEFITS • Drive simulations with standard Electric Vehicle tests: FUDS, SFUDS, GSFUDS, DST and ECE-15L • Drive Cycle Conversion utility automates test program development from acquired battery usage data • Constant Current, Power or Voltage Control • Bipolar capacity for discharging to below zero volts • Parallel circuit operation for greater flexibility in test specification • Assignable Data Channels • Test control and data management with Bitrode’s VisuaLCN Lab Client software suite System Options Bitrode Model MCV8-100-12 (shown with optional side box) GENERAL SPECIFICATIONS Voltage: Current: Accuracy: Resolution: Data Sampling Rate: 0-18V (other voltages optional) 1µA-300A ±0.1% of FS* 16 bit 100ms (other ranges optional) • Multiple current ranges per circuit • High impedance cell voltage monitoring • Temperature compensation - adjusts voltage per battery temperature • Pressure monitoring • Internal resistance • Programmable analog or digital inputs and outputs • Remote Input Output (RIO) box - reduces excessive cable lengths when connecting to remote test stations • Constant resistance discharge • Customer-specified alarms and faults • Custom-designed test leads • Custom-designed cell or battery handling fixtures *Accuracy values are conservative assuming operation will be through the standard temperature range of 0-40˚ C and RH from 10-90% (non-condensing). Units calibrated and maintained in a temperature and humidity controlled environment can expect an accuracy of 0.02-0.05%FS. Bitrode, Inc.©2012 www.bitrode.com innovation in energy innovation in energy MCV Model EV/HEV Battery Pack Testing System General Configurations - Contact bitrode for your custom specification requirements Model* MVC16-25-12 MCV24-50-12 MCV8-100-12 MCV32-10-12 Model* MVC16-25-12 MCV24-50-12 MCV8-100-12 MCV32-10-12 Constant Current Amp Range 0.00-25.00 0.00-50.00 0.00-100.00 0.000-10.000 Charge Voltage 0.000-18.000 0.000-18.000 0.000-18.000 0.000-18.000 Discharge Voltage 0.000-18.000 0.000-18.000 0.000-18.000 0.000-18.000 Circuits Cabinet Input Amps (50 or 60HZ) Dimensions† per Three Phase in/cm Cabinet 230V400V 480V W D H 16 39 22 19 23/59 34/87 78/199 24 107 61 51 67/171 34/87 78/199 8 69 40 33 45/115 34/87 78/199 32 38 22 18 35/89 44/112 78/199 Constant Wattage 450.00 900.0 1800 120.0 Weight† lb/kg 1200/540 3000/1350 3000/1350 1800/810 * If required specifications do not appear in this table, contact Bitrode Corporation; custom product engineering is one of our greatest strengths. Module names are interpreted as follows: MCVxx-yy-zz, where xx indicates number of circuits per cabinet, yy indicates amperage and zz indicates voltage. † Dimensions and Weight may vary according to design requirements. All specifications subject to change. BITRODE CORPORATION 9787 Green Park Industrial Drive St. Louis, Missouri 63123 USA Tel: (636) 343.6112 • Fax: (636) 343.7473 email: sales1@bitrode.com web: www.bitrode.com BITRODE EU/SOVEMA SPA via Spagna, 13 37069 Villafranca (Verona), Italy Tel: +39.045.6335711 • Fax: +39.045.6303911 Contact Person: Mr. Roberto Vecchia Tel: +39.045.6335725 • Mobile: +39.331.6338697 email: roberto.vecchia@bitrode.eu BITRODE UK OFFICE Tel: 44 1242 23111 Contact Person: Mr. Graham Peters email: sales@bitrode.co.uk