Configuration Questions

Transcription

Configuration Questions
Configuration Questions:
1.
What equipment will be protected?
–
2.
What do I want the UPS to do?
–
–
3.
Desk side or rack mount?
Power quality at the site
–
5.
Shutdown server(s) – interface?
Provide extended battery (autonomy)
runtime?
Where do I want the UPS installed?
–
4.
Calculate using Table 1
Office (series 5 – 9) or industrial (series
9) grade protection?
Determine power available on site
–
Voltage, is it 208 – 240V or 120V?
•
–
If 120V needs to be less than 1400 Watts
and desk side UPS
Limited amperage?
•
15A, 20A, 30A or 60A?
www.powerware.com/ibm
p5 Rack Flow Chart v14.ppt Page 1 of 10
May 22, 2007
p5 Support – North America
All devices and
UPS in One rack?
No
9910-UPS Rack Chart
Updated May ‘07
Go to Tower UPS Charts
or Contact Eaton (Powerware)
1 800 925 4426 Opt. 1 (U.S.)
Yes
One to Two*
or Two or Four** 91887188 PDUs?
One 9176 PDU?
(Figure 3)
No
If LPAR’s or Web/SNMP connectivity
(interface) required, select FC 2934. If no LPAR’s
ensure p5 has #5723 for serial communications.
Model
Watts
9110-510, 9110-51A
9910-51A 4-way
9111-520, 9111-285
9113-550, 55A
9115-505
475
625
750
1100
500
779
9117-570 2 core active mode
Calculate power draw, select UPS with
watt rating higher than power draw
#0231, 2-4core Base CEC
#0241, 9-12 core 3rd CEC
Select from P30, P33, P64 or P65 UPS
#0241 or 0242, 13-16core 4th CEC
The
Thefollowing
followingtexts
texts describes
describes various
various UPSs
UPSs and
andthe
the configuration
configuration (e.g.
(e.g.
“No
“NoPDU”)
PDU”)and
and features
features necessary
necessaryfor
for aa proper
proper configuration
configuration
P30 (No PDU) Fig. 5
P33 (No PDU) Fig. 5
Qty
TTL
Watts
9916-561 & 9117-570:
#0232 & 0260, 5-8core 2nd CEC
2,100W 2U
9910-6630 rail kit
9910-9010 rack factory install
9910-9830 IEC power cord kit
9910-9860/61 (L6-20) power cord
or: 9910-2975 (L6-30) power cord
P30 Options:
9910-6640 2U Battery module
9910-6630 rail kit
9910-9010 rack factory install
Table 1
No
Yes
Yes
p5
P30 (One*Fig. 2 or two** Fig. 4
9/7188 PDUs)
2,100W 2U
9910-6630 rail kit
9910-9010 rack factory install
9910-9830 IEC power cord kit
9910-9860/61 (L6-20) power cord
or: 9910-2975 (L6-30) power cord
9910-2974 PDU to UPS power cord
P30 Options:
9910-6640 2U Battery module
9910-6630 rail kit
9910-9010 rack factory install
9118-575 p5 575 Max.
9119-590 p5 590 Max.
9119-595 p5 595 Max.
7037-A50, 7047-185
7037-A50 2-way
1722-60U
1740-710
1742-90U
1750-511, EX1
2005-B16
2005-H08
2104-DS4
3494-L22
3580-L23, 3581-F28
3581-L28
3582-All
7031-D24
7210-025, 030
7212-102
7310-CR3
7311-D11, D20
7316-TF3
Other
1400
2800
4200
5600
41,600
22,700
22,700
530
750
390
390
200
800
75
50
330
750
100
168
200
700
250
42
185
300
20
2,700W 2U
P33 (One*Fig. 2 or two** Fig. 4
9910-6630 rail kit
9/7188 PDUs)
9910-9010 rack factory install
2,700W 2U
9910-9830 IEC power cord kit
9910-6630 rail kit; or,
9910-9860/61 (L6-20) power cord 9910-6632 (if S11 or S25 rack)
or: 9910-2975 (L6-30) power cord 9910-9010 rack factory install
P33 Options:
9910-9830 IEC power cord kit
9910-6607 2U Battery module
9910-2974 PDU to UPS
9910-6630 rail kit
power cord
9910-9010 rack factory install
9910-2975 (L6-30) UPS input P64 (One*Fig. 6 or two**
P65 (One* Fig. 6, two* Fig 7 or 8
power cord
Fig. 7 9/7188 PDUs)
or four** Fig. 9 or 10 9/7188 PDUs)
P33 Options:
4,200W 5U
4,500W 3U
9910-6607 2U Battery module
9910-6631 rail kit
9910-6632 rail kit
9910-6630 rail kit
9910-9010 rack factory install
9910-9010 rack factory install
9910-9010 rack factory install
9910-1420/21 (L6-30) power cord 9910-1420/21 (L6-30) power cord
9910-2972 or 2973
PDU to UPS power cord
P64 Options:
9910-6641 3U Battery module
9910-6631 rail kit
9910-9010 rack factory install
Figures on
Following Pages
*Non-redundant.
*Non-redundant. **
** Dual-Redundant
Dual-Redundant
9188 & 7188 PDU NOTES:
P30 & P33 – You will not use the 9/7188
PDU #66xx power cord, store for future use.
Toll-free IBM pre-sales support & application engineering @ (U.S.) 800 925 4426 option 1
www.powerware.com/ibm
p5 Rack Flow Chart v14.ppt Page 2 of 10
May 22, 2007
9910-2972 or 2973 PDU to UPS power cord
NOTE: The P65 can support one
(1) additional PDU. Select one 9910-2974
PDU to UPS power cord for second PDU.
P65 Options:
9910-6641 3U Battery module
9910-6631 rail kit
9910-9010 rack factory install
p5 Support – North America
Table 2
Attribute
P30
P33
P64
P65
Level of protection (Type/Series) 9 = Double
conversion, 5 = line interactive
9
5
9
5
Hot Swap Batteries
Y
Y
Y
Y
Hot Swap Electronics
-
Y
-
Y
Load Segments
Y
Y
-
Y
No. PDU supported, non-redundant
1
1
1
2
No. PDU supported, dual-redundant
2
2
2
4
Rack Height U
2
2
5
3
Output Watts
2,100
2,700
4,200
4,500
Watts per U
1,050
1,350
840
1,500
Optional Extended Battery Modules (EBM)
Y (#6640)
Max: 4
Y (#6607)
Max: 4
Y (#6641)
Max: 4
Y (#6641)
Max: 4
Optional X-Slot Web/SNMP Card for LPARs (#2934)
Y, Max: 1
Y, Max: 1
Y, Max: 1
Y, Max: 1
Optional Env. Monitoring Probe (1) (#2938)
Y, Max: 1
Y, Max: 1
Y, Max: 1
Y, Max: 1
Optional 120V Convenience PDU (#2916)
Y, Max: 1
Y, Max: 1
Y(2)
Y, Max: 1
(1) Requires FC 2934. (2) Requires 9188, 7188 or 9176 to power 120V Convenience PDU
Diagrams not to scale
www.powerware.com/ibm
p5 Rack Flow Chart v14.ppt Page 3 of 10
May 22, 2007
p5 Support – North America
Step
Step 1:
1: Determine
Determine your
your rack
rack model:
model: 7014-T42
7014-T42 == 42U.
42U. 7014-S25
7014-S25 == 25U.
25U.
7014-S11
7014-S11 == 11U.
11U. PDUs
PDUs can
can be
be installed
installed in
in side
side pockets
pockets (42U
(42U only)
only) or
or
EIA
space
(all).
The
25U
and
11U
racks
support
9910-P33
UPS.
A
EIA space (all). The 25U and 11U racks support 9910-P33 UPS. A
minimum
minimum of
of one
one PDU
PDU will
will be
be included
included with
with each
each rack.
rack.
Choose
Choose the
the figure
figure closest
closest to
to your
your application.
application.
42U Rack
(T42)
PDU (side pocket)
PDU (side pocket)
PDU (side pocket)
PDU (side pocket)
Device
PDU (EIA space)
Model
Model UPS
UPS Support
Support by
by racks:
racks:
T42
supports
P30,
P33,
P64
and
T42 supports P30, P33, P64 and P65
P65 (Figure
(Figure 1A)
1A)
S25
S25 supports
supports P33
P33 (Figure
(Figure 1B)
1B)
S11
S11 supports
supports P33
P33 (Figure
(Figure 1C)
1C)
25U Rack
(S25)
11U Rack (S11)
UPS (varies)
Figure 1A
Device
Device
PDU (EIA space)
PDU (EIA space)
UPS (P33)
UPS (P33)
Figure 1B
Figure 1C
Diagrams not to scale
www.powerware.com/ibm
p5 Rack Flow Chart v14.ppt Page 4 of 10
May 22, 2007
p5 Support – North America
Battery
Battery (autonomy)
(autonomy) runtimes
runtimes
Std
Internal
Batts
+1
EBM
+2
EBMs
+3
EBMs
+4
EBMs
16 min
57
90
150
200
1050 W
13
55
72
120
150
1750 W
7
28
48
68
88
2100 W
5
25
38
54
70
1350 W
15
61
103
146
190
2700 W
5
25
49
69
90
1400 W
38
108
186
271
362
2100 W
34
70
122
178
237
2800 W
19
49
86
125
168
3500 W
13
37
65
96
128
4200 W
10
30
52
76
102
900 W
59
169
303
452
612
1800 W
26
79
138
204
274
2700 W
15
49
85
125
168
3150 W
13
43
73
110
142
4050 W
8
27
52
76
89
4500 W
7
24
46
67
80
Battery (Autonomy) Runtimes @
Watt load
P30 (EBM #6640)
875 Watts
P33 (EBM #6607)
P64 (EBM #6641)
P65 (EBM #6641)
Sample
Power draw (load)
Watts
=
Runtime desired
Minutes
=
UPS and EBM configuration:
Sample
Power draw (load)
Watts
=
Runtime desired
Minutes
=
UPS and EBM configuration:
Diagrams not to scale
www.powerware.com/ibm
p5 Rack Flow Chart v14.ppt Page 5 of 10
May 22, 2007
p5 Support – North America
Each
Each Figure
Figure shows
shows aa rack
rack with
with aa different
different quantity
quantity of
of PDUs
PDUs (zero
(zero to
to four)
four) and
and with
with
various
input
power
cord
types
for
the
P30
&
P33.
The
Figures
showing
two
PDUs
various input power cord types for the P30 & P33. The Figures showing two PDUs
are
are show
show in
in *Non*Non- &
& **Dual-Redundant
**Dual-Redundant (two
(two separate
separate power
power sources)
sources) configurations.
configurations.
The
The figures
figures showing
showing four
four PDUs
PDUs are
are shown
shown in
in Dual-Redundant
Dual-Redundant configurations
configurations only.
only.
Choose
Choose the
the figure
figure closest
closest to
to your
your application.
application.
Figure 2
One 9188 PDU:
P30/P33
PDU
9188/
7188
Rack
with one PDU
Connector
Type: UTG
(Burndy)
*NON-REDUNDANT
POWER
(not to scale)
PDU to UPS power
cord 6’, #2974
Up to 12 Devices (power
connections) to 9188
...
C19/C20
Device #1
30A UPS input
power cord
#2975 L6-30P 8’
#2974
P30 or P33
Figure 3
20A UPS input
power cord
#9860 L6-20P 14’
#9861 L6-20P 6’
PDU
9176
One 9176 PDU:
P30/P33 with 9851
Rack
with one PDU
*NON-REDUNDANT
POWER
(not to scale)
Up to 6 Devices (power
connections) to 5160
...
P30
or P33
Or
NOTE: If you want a
30A power cord,
you must delete the
98xx from the UPS
configuration, then
select #9851.
Then you must
order #1420 (14ft)
or #1421 (6ft).
#9851 consists of two
parts and connects:
1) PDU to UPS
(PN 53P1966).
2) UPS input to PDU
line cord (PN 53P1967).
L6-30P
L6-30R
53P1966
53P1967
C19/C20
P30 or
P33
Device #1
L6-30R L6-30P
P30 or
P33
Diagrams not to scale
www.powerware.com/ibm
p5 Rack Flow Chart v14.ppt Page 6 of 10
May 22, 2007
p5 Support – North America
Figure 4
Figure 5
Two 9/7188 PDUs:
P30/P33
No PDU:
P30/P33
Rack
with two PDU
Rack
with No PDU
**DUAL-REDUNDANT
POWER
*NON-REDUNDANT
POWER
(not to scale)
(not to scale)
Up to 12 Devices (power
connections) to 9/7188
Up to 9 Devices (power
connections) to P33. Up to
4 power connections
to P30.
...
Device #1
PDU #2
line cord
#2
C13 to C14
power cord
...
Device #1
#2974
P30 or P33
Figure 6
UPS input line
cord types:
#1420 L6-30P
#1421 L6-30P
#1422 RS3750
#1423 RS3750
#1424 IEC309
P+N+G 32A
#1425 PDL
#1426 KP
#1427 PDL NZ
P30 or P33
One 9188 PDU:
P64 or P65
Figure 7
Two 9/7188 PDUs:
P64 or P65
Rack
with one PDU
Rack
with two PDUs
*NON-REDUNDANT
POWER
**DUAL-REDUNDANT
POWER
PDU #1 powered by
UPS. PDU #2 powered
from utility (mains)
Up to 12 Devices (power
connections) w/ 7188
Up to 12 Devices (power
connections) w/ 7188
..
See UPS
input line
cord types
Device #1
..
Device #1
#2972/3
cord
#2972/3
cord
P64 or P65
P64 or P65
#2
PDU #2
line cord
Diagrams not to scale
www.powerware.com/ibm
p5 Rack Flow Chart v14.ppt Page 7 of 10
May 22, 2007
p5 Support – North America
Figure 8
Figure 9
Two 9/7188 PDUs:
P65
Four 9/7188 PDUs:
P65
Rack
with two PDUs
Rack
with four PDUs
*NON-REDUNDANT
POWER
**DUAL-REDUNDANT
POWER
PDU #1 & #2 powered
by UPS.
PDUs #1 & #3 powered
by UPS. PDUs # 2 & 4
powered by utility (mains).
#2974
PDU #3 to
UPS cord
Up to 12 Devices (power
connections) to each 7188
See UPS
input line
cord types
..
Up to 12 Devices (power
connections) to each 7188
..
See UPS
input line
cord types
#2974
PDU to
UPS cord
#2
Device #1
Device #1
#2972/3
cord
See PDU
input line
cord types
#2
PDU #2
line cord
#2972/ 3
cord
P65
Figure 10
PDU #4
line cord
P65
Two Racks:
P65 (requires 1x #2972 or #6654 and 1x #2974)
Rack #1
with two PDUs
Rack #2
with two PDUs
*REDUNDANT
POWER
*REDUNDANT
POWER
PDU #2 powered
by UPS.
PDU #1 powered
by UPS.
Up to 12 Devices (power
connections) to each 7188
Up to 12 Devices (power
connections) to each 7188
..
Device #1
#2
See UPS
input line
cord types
..
Device #1
#2
PDU #2
line cord
#2974
cord
P65
#2972 or #6654 PDU to UPS cord
Diagrams not to scale
www.powerware.com/ibm
p5 Rack Flow Chart v14.ppt Page 8 of 10
May 22, 2007
p5 Support – North America
Figure 11
NEMA L6-30 (2P+G) 30A, 208V used with UPS
input power cord #2975, PDU to UPS power
cord #2972, #2973, P65 input power cable (1.5ft)
and P64/P65 outlet; and, 9188 or 7188 rack PDUs.
NEMA L6-20 (2P+G) 20A, 208V used with UPS
input power cord #9860 and #9861.
C13 connector- 10A rated (female)
Rack PDU, P30/P33/P65 UPS outlets
Mating connector to server
C14 connector- 10A rated (male)
The inlet on most servers & options
Rack jumper cords
C19 connector- 16A rated (female)
P30/P33/P65 UPS outlet and
UPS input power cord (2975, 2976)
C20 connector- 16A rated (male)
BladeCenter, some i5 devices
and P30/P33 inlets
Figure 12
Figure 13
FC 2975 UPS input
(mains) power cord 8ft.
L6-30P to IEC-320-C19
FC 2972, 2973 & 6654
PDU to UPS power cord
14ft/4m, 4ft/1.2m
Burndy to L6-30P
C19
Figure 15
Figure 14
FC 2974 PDU to UPS
power cord 6ft/1.8m.
Burndy to IEC-320-C20
FC 2976 UPS input
(mains) power cord
4m. IEC309 (P+N+G)
32A to IEC-320-C19
C20
C19
Table 4 Mains (input) Power Cord Plug & Receptacle Descriptions
Type 11
FC 9860, 9861
(NEMA L6-20)
Type 12
FC 1420, 1421, 1424,
1426, 2970, 2971, 2972
2975, 6654 (NEMA L6-30)
Type 40
FC 1422, 1423
6655, R&S 3750
Type 46 (16A)
FC 9871, 1421
IEC309 P+N+G
Type 46 (32A)
FC 1424, 1449, 2976
6656, IEC309 P+N+G
Type 64
FC 9875
iNMETRO
Diagrams not to scale
www.powerware.com/ibm
p5 Rack Flow Chart v14.ppt Page 9 of 10
May 22, 2007
p5 Support – North America
UPS Rear Panels
P30
Figure 16
P33
Figure 17
P64
Figure 18
P65
Figure 19
Diagrams not to scale
www.powerware.com/ibm
p5 Rack Flow Chart v14.ppt Page 10 of 10
May 22, 2007
p5 Support – North America