Configuration Questions
Transcription
Configuration Questions
Configuration Questions: 1. What equipment will be protected? – 2. What do I want the UPS to do? – – 3. Desk side or rack mount? Power quality at the site – 5. Shutdown server(s) – interface? Provide extended battery (autonomy) runtime? Where do I want the UPS installed? – 4. Calculate using Table 1 Office (series 5 – 9) or industrial (series 9) grade protection? Determine power available on site – Voltage, is it 208 – 240V or 120V? • – If 120V needs to be less than 1400 Watts and desk side UPS Limited amperage? • 15A, 20A, 30A or 60A? www.powerware.com/ibm p5 Rack Flow Chart v14.ppt Page 1 of 10 May 22, 2007 p5 Support – North America All devices and UPS in One rack? No 9910-UPS Rack Chart Updated May ‘07 Go to Tower UPS Charts or Contact Eaton (Powerware) 1 800 925 4426 Opt. 1 (U.S.) Yes One to Two* or Two or Four** 91887188 PDUs? One 9176 PDU? (Figure 3) No If LPAR’s or Web/SNMP connectivity (interface) required, select FC 2934. If no LPAR’s ensure p5 has #5723 for serial communications. Model Watts 9110-510, 9110-51A 9910-51A 4-way 9111-520, 9111-285 9113-550, 55A 9115-505 475 625 750 1100 500 779 9117-570 2 core active mode Calculate power draw, select UPS with watt rating higher than power draw #0231, 2-4core Base CEC #0241, 9-12 core 3rd CEC Select from P30, P33, P64 or P65 UPS #0241 or 0242, 13-16core 4th CEC The Thefollowing followingtexts texts describes describes various various UPSs UPSs and andthe the configuration configuration (e.g. (e.g. “No “NoPDU”) PDU”)and and features features necessary necessaryfor for aa proper proper configuration configuration P30 (No PDU) Fig. 5 P33 (No PDU) Fig. 5 Qty TTL Watts 9916-561 & 9117-570: #0232 & 0260, 5-8core 2nd CEC 2,100W 2U 9910-6630 rail kit 9910-9010 rack factory install 9910-9830 IEC power cord kit 9910-9860/61 (L6-20) power cord or: 9910-2975 (L6-30) power cord P30 Options: 9910-6640 2U Battery module 9910-6630 rail kit 9910-9010 rack factory install Table 1 No Yes Yes p5 P30 (One*Fig. 2 or two** Fig. 4 9/7188 PDUs) 2,100W 2U 9910-6630 rail kit 9910-9010 rack factory install 9910-9830 IEC power cord kit 9910-9860/61 (L6-20) power cord or: 9910-2975 (L6-30) power cord 9910-2974 PDU to UPS power cord P30 Options: 9910-6640 2U Battery module 9910-6630 rail kit 9910-9010 rack factory install 9118-575 p5 575 Max. 9119-590 p5 590 Max. 9119-595 p5 595 Max. 7037-A50, 7047-185 7037-A50 2-way 1722-60U 1740-710 1742-90U 1750-511, EX1 2005-B16 2005-H08 2104-DS4 3494-L22 3580-L23, 3581-F28 3581-L28 3582-All 7031-D24 7210-025, 030 7212-102 7310-CR3 7311-D11, D20 7316-TF3 Other 1400 2800 4200 5600 41,600 22,700 22,700 530 750 390 390 200 800 75 50 330 750 100 168 200 700 250 42 185 300 20 2,700W 2U P33 (One*Fig. 2 or two** Fig. 4 9910-6630 rail kit 9/7188 PDUs) 9910-9010 rack factory install 2,700W 2U 9910-9830 IEC power cord kit 9910-6630 rail kit; or, 9910-9860/61 (L6-20) power cord 9910-6632 (if S11 or S25 rack) or: 9910-2975 (L6-30) power cord 9910-9010 rack factory install P33 Options: 9910-9830 IEC power cord kit 9910-6607 2U Battery module 9910-2974 PDU to UPS 9910-6630 rail kit power cord 9910-9010 rack factory install 9910-2975 (L6-30) UPS input P64 (One*Fig. 6 or two** P65 (One* Fig. 6, two* Fig 7 or 8 power cord Fig. 7 9/7188 PDUs) or four** Fig. 9 or 10 9/7188 PDUs) P33 Options: 4,200W 5U 4,500W 3U 9910-6607 2U Battery module 9910-6631 rail kit 9910-6632 rail kit 9910-6630 rail kit 9910-9010 rack factory install 9910-9010 rack factory install 9910-9010 rack factory install 9910-1420/21 (L6-30) power cord 9910-1420/21 (L6-30) power cord 9910-2972 or 2973 PDU to UPS power cord P64 Options: 9910-6641 3U Battery module 9910-6631 rail kit 9910-9010 rack factory install Figures on Following Pages *Non-redundant. *Non-redundant. ** ** Dual-Redundant Dual-Redundant 9188 & 7188 PDU NOTES: P30 & P33 – You will not use the 9/7188 PDU #66xx power cord, store for future use. Toll-free IBM pre-sales support & application engineering @ (U.S.) 800 925 4426 option 1 www.powerware.com/ibm p5 Rack Flow Chart v14.ppt Page 2 of 10 May 22, 2007 9910-2972 or 2973 PDU to UPS power cord NOTE: The P65 can support one (1) additional PDU. Select one 9910-2974 PDU to UPS power cord for second PDU. P65 Options: 9910-6641 3U Battery module 9910-6631 rail kit 9910-9010 rack factory install p5 Support – North America Table 2 Attribute P30 P33 P64 P65 Level of protection (Type/Series) 9 = Double conversion, 5 = line interactive 9 5 9 5 Hot Swap Batteries Y Y Y Y Hot Swap Electronics - Y - Y Load Segments Y Y - Y No. PDU supported, non-redundant 1 1 1 2 No. PDU supported, dual-redundant 2 2 2 4 Rack Height U 2 2 5 3 Output Watts 2,100 2,700 4,200 4,500 Watts per U 1,050 1,350 840 1,500 Optional Extended Battery Modules (EBM) Y (#6640) Max: 4 Y (#6607) Max: 4 Y (#6641) Max: 4 Y (#6641) Max: 4 Optional X-Slot Web/SNMP Card for LPARs (#2934) Y, Max: 1 Y, Max: 1 Y, Max: 1 Y, Max: 1 Optional Env. Monitoring Probe (1) (#2938) Y, Max: 1 Y, Max: 1 Y, Max: 1 Y, Max: 1 Optional 120V Convenience PDU (#2916) Y, Max: 1 Y, Max: 1 Y(2) Y, Max: 1 (1) Requires FC 2934. (2) Requires 9188, 7188 or 9176 to power 120V Convenience PDU Diagrams not to scale www.powerware.com/ibm p5 Rack Flow Chart v14.ppt Page 3 of 10 May 22, 2007 p5 Support – North America Step Step 1: 1: Determine Determine your your rack rack model: model: 7014-T42 7014-T42 == 42U. 42U. 7014-S25 7014-S25 == 25U. 25U. 7014-S11 7014-S11 == 11U. 11U. PDUs PDUs can can be be installed installed in in side side pockets pockets (42U (42U only) only) or or EIA space (all). The 25U and 11U racks support 9910-P33 UPS. A EIA space (all). The 25U and 11U racks support 9910-P33 UPS. A minimum minimum of of one one PDU PDU will will be be included included with with each each rack. rack. Choose Choose the the figure figure closest closest to to your your application. application. 42U Rack (T42) PDU (side pocket) PDU (side pocket) PDU (side pocket) PDU (side pocket) Device PDU (EIA space) Model Model UPS UPS Support Support by by racks: racks: T42 supports P30, P33, P64 and T42 supports P30, P33, P64 and P65 P65 (Figure (Figure 1A) 1A) S25 S25 supports supports P33 P33 (Figure (Figure 1B) 1B) S11 S11 supports supports P33 P33 (Figure (Figure 1C) 1C) 25U Rack (S25) 11U Rack (S11) UPS (varies) Figure 1A Device Device PDU (EIA space) PDU (EIA space) UPS (P33) UPS (P33) Figure 1B Figure 1C Diagrams not to scale www.powerware.com/ibm p5 Rack Flow Chart v14.ppt Page 4 of 10 May 22, 2007 p5 Support – North America Battery Battery (autonomy) (autonomy) runtimes runtimes Std Internal Batts +1 EBM +2 EBMs +3 EBMs +4 EBMs 16 min 57 90 150 200 1050 W 13 55 72 120 150 1750 W 7 28 48 68 88 2100 W 5 25 38 54 70 1350 W 15 61 103 146 190 2700 W 5 25 49 69 90 1400 W 38 108 186 271 362 2100 W 34 70 122 178 237 2800 W 19 49 86 125 168 3500 W 13 37 65 96 128 4200 W 10 30 52 76 102 900 W 59 169 303 452 612 1800 W 26 79 138 204 274 2700 W 15 49 85 125 168 3150 W 13 43 73 110 142 4050 W 8 27 52 76 89 4500 W 7 24 46 67 80 Battery (Autonomy) Runtimes @ Watt load P30 (EBM #6640) 875 Watts P33 (EBM #6607) P64 (EBM #6641) P65 (EBM #6641) Sample Power draw (load) Watts = Runtime desired Minutes = UPS and EBM configuration: Sample Power draw (load) Watts = Runtime desired Minutes = UPS and EBM configuration: Diagrams not to scale www.powerware.com/ibm p5 Rack Flow Chart v14.ppt Page 5 of 10 May 22, 2007 p5 Support – North America Each Each Figure Figure shows shows aa rack rack with with aa different different quantity quantity of of PDUs PDUs (zero (zero to to four) four) and and with with various input power cord types for the P30 & P33. The Figures showing two PDUs various input power cord types for the P30 & P33. The Figures showing two PDUs are are show show in in *Non*Non- & & **Dual-Redundant **Dual-Redundant (two (two separate separate power power sources) sources) configurations. configurations. The The figures figures showing showing four four PDUs PDUs are are shown shown in in Dual-Redundant Dual-Redundant configurations configurations only. only. Choose Choose the the figure figure closest closest to to your your application. application. Figure 2 One 9188 PDU: P30/P33 PDU 9188/ 7188 Rack with one PDU Connector Type: UTG (Burndy) *NON-REDUNDANT POWER (not to scale) PDU to UPS power cord 6’, #2974 Up to 12 Devices (power connections) to 9188 ... C19/C20 Device #1 30A UPS input power cord #2975 L6-30P 8’ #2974 P30 or P33 Figure 3 20A UPS input power cord #9860 L6-20P 14’ #9861 L6-20P 6’ PDU 9176 One 9176 PDU: P30/P33 with 9851 Rack with one PDU *NON-REDUNDANT POWER (not to scale) Up to 6 Devices (power connections) to 5160 ... P30 or P33 Or NOTE: If you want a 30A power cord, you must delete the 98xx from the UPS configuration, then select #9851. Then you must order #1420 (14ft) or #1421 (6ft). #9851 consists of two parts and connects: 1) PDU to UPS (PN 53P1966). 2) UPS input to PDU line cord (PN 53P1967). L6-30P L6-30R 53P1966 53P1967 C19/C20 P30 or P33 Device #1 L6-30R L6-30P P30 or P33 Diagrams not to scale www.powerware.com/ibm p5 Rack Flow Chart v14.ppt Page 6 of 10 May 22, 2007 p5 Support – North America Figure 4 Figure 5 Two 9/7188 PDUs: P30/P33 No PDU: P30/P33 Rack with two PDU Rack with No PDU **DUAL-REDUNDANT POWER *NON-REDUNDANT POWER (not to scale) (not to scale) Up to 12 Devices (power connections) to 9/7188 Up to 9 Devices (power connections) to P33. Up to 4 power connections to P30. ... Device #1 PDU #2 line cord #2 C13 to C14 power cord ... Device #1 #2974 P30 or P33 Figure 6 UPS input line cord types: #1420 L6-30P #1421 L6-30P #1422 RS3750 #1423 RS3750 #1424 IEC309 P+N+G 32A #1425 PDL #1426 KP #1427 PDL NZ P30 or P33 One 9188 PDU: P64 or P65 Figure 7 Two 9/7188 PDUs: P64 or P65 Rack with one PDU Rack with two PDUs *NON-REDUNDANT POWER **DUAL-REDUNDANT POWER PDU #1 powered by UPS. PDU #2 powered from utility (mains) Up to 12 Devices (power connections) w/ 7188 Up to 12 Devices (power connections) w/ 7188 .. See UPS input line cord types Device #1 .. Device #1 #2972/3 cord #2972/3 cord P64 or P65 P64 or P65 #2 PDU #2 line cord Diagrams not to scale www.powerware.com/ibm p5 Rack Flow Chart v14.ppt Page 7 of 10 May 22, 2007 p5 Support – North America Figure 8 Figure 9 Two 9/7188 PDUs: P65 Four 9/7188 PDUs: P65 Rack with two PDUs Rack with four PDUs *NON-REDUNDANT POWER **DUAL-REDUNDANT POWER PDU #1 & #2 powered by UPS. PDUs #1 & #3 powered by UPS. PDUs # 2 & 4 powered by utility (mains). #2974 PDU #3 to UPS cord Up to 12 Devices (power connections) to each 7188 See UPS input line cord types .. Up to 12 Devices (power connections) to each 7188 .. See UPS input line cord types #2974 PDU to UPS cord #2 Device #1 Device #1 #2972/3 cord See PDU input line cord types #2 PDU #2 line cord #2972/ 3 cord P65 Figure 10 PDU #4 line cord P65 Two Racks: P65 (requires 1x #2972 or #6654 and 1x #2974) Rack #1 with two PDUs Rack #2 with two PDUs *REDUNDANT POWER *REDUNDANT POWER PDU #2 powered by UPS. PDU #1 powered by UPS. Up to 12 Devices (power connections) to each 7188 Up to 12 Devices (power connections) to each 7188 .. Device #1 #2 See UPS input line cord types .. Device #1 #2 PDU #2 line cord #2974 cord P65 #2972 or #6654 PDU to UPS cord Diagrams not to scale www.powerware.com/ibm p5 Rack Flow Chart v14.ppt Page 8 of 10 May 22, 2007 p5 Support – North America Figure 11 NEMA L6-30 (2P+G) 30A, 208V used with UPS input power cord #2975, PDU to UPS power cord #2972, #2973, P65 input power cable (1.5ft) and P64/P65 outlet; and, 9188 or 7188 rack PDUs. NEMA L6-20 (2P+G) 20A, 208V used with UPS input power cord #9860 and #9861. C13 connector- 10A rated (female) Rack PDU, P30/P33/P65 UPS outlets Mating connector to server C14 connector- 10A rated (male) The inlet on most servers & options Rack jumper cords C19 connector- 16A rated (female) P30/P33/P65 UPS outlet and UPS input power cord (2975, 2976) C20 connector- 16A rated (male) BladeCenter, some i5 devices and P30/P33 inlets Figure 12 Figure 13 FC 2975 UPS input (mains) power cord 8ft. L6-30P to IEC-320-C19 FC 2972, 2973 & 6654 PDU to UPS power cord 14ft/4m, 4ft/1.2m Burndy to L6-30P C19 Figure 15 Figure 14 FC 2974 PDU to UPS power cord 6ft/1.8m. Burndy to IEC-320-C20 FC 2976 UPS input (mains) power cord 4m. IEC309 (P+N+G) 32A to IEC-320-C19 C20 C19 Table 4 Mains (input) Power Cord Plug & Receptacle Descriptions Type 11 FC 9860, 9861 (NEMA L6-20) Type 12 FC 1420, 1421, 1424, 1426, 2970, 2971, 2972 2975, 6654 (NEMA L6-30) Type 40 FC 1422, 1423 6655, R&S 3750 Type 46 (16A) FC 9871, 1421 IEC309 P+N+G Type 46 (32A) FC 1424, 1449, 2976 6656, IEC309 P+N+G Type 64 FC 9875 iNMETRO Diagrams not to scale www.powerware.com/ibm p5 Rack Flow Chart v14.ppt Page 9 of 10 May 22, 2007 p5 Support – North America UPS Rear Panels P30 Figure 16 P33 Figure 17 P64 Figure 18 P65 Figure 19 Diagrams not to scale www.powerware.com/ibm p5 Rack Flow Chart v14.ppt Page 10 of 10 May 22, 2007 p5 Support – North America