Parallam (PSL) - Atlas Structural Systems
Transcription
#TJ-9000 SPECIFIER’S GUIDE BEAMS, HEADERS, AND COLUMNS Featuring Trus Joist® TimberStrand® LSL, Microllam® LVL, and Parallam® PSL • Uniform and Predictable • Minimal Bowing, Twisting, and Shrinking • Strong and Straight • Limited Product Warranty woodbywy.com 1.888.453.8358 Why Choose Trus Joist® Beams, Columns, and Headers? •Reliable performance •Consistent quality and dependable uniformity •Flexible solutions for your beam and header needs •Backed by a limited product warranty The products in this guide are readily available through our n ationwide network of distributors and dealers. For more information on other applications or other Trus Joist products, contact your Weyerhaeuser representative. Using advanced technology, Weyerhaeuser manufactures engineered lumber that is consistently straight and strong, and resists bowing, twisting, and shrinking. That means less waste, easier installation, and higher design values for starters; plus fewer callbacks, shorter cycle times, more design flexibility, and lower overall installed cost in the end. Trus Joist® TimberStrand® LSL, Microllam® LVL, and Parallam® PSL are structural solutions you can count on—guaranteed. TABLE OF CONTENTS Design Properties Sizing Tables Window and Door Headers Headers Supporting Roof Ridge Beams Headers Supporting Floor and Roof Floor Beams Floor Load Tables TimberStrand® LSL Microllam® LVL Parallam® PSL Snow Roof Load Tables TimberStrand® LSL Microllam® LVL Parallam® PSL Non-Snow Roof Load Tables TimberStrand® LSL Microllam® LVL Parallam® PSL Beam Details Window and Door Header Details Nailing on Narrow Face Allowable Holes Bearing Length Requirements Tapered End Cuts Multiple-Member Connections Framing Connectors Columns Product Warranty 4-5 6–7 8–9 10–11 This guide features Trus Joist® engineered lumber in the following widths and depths: • TimberStrand® LSL 12–13 14–15 1.55E TimberStrand® LSL sizes: Widths: 1¾" and 3½" Depths: 9¼", 9½", 11¼", 117⁄8", 14", and 16" 16–17 18–19 20–21 1.3E TimberStrand® LSL header sizes: Width: 3½" Depths: 43⁄8", 5½", 7¼", 85⁄8", 9¼", and 11¼" 22–23 24–25 26–27 1.3E TimberStrand® LSL column and post sizes: 3½" x 3½" 3½" x 43⁄8" 3½" x 5½" 31⁄2" x 7¼" 3½" x 85⁄8" • Microllam® LVL 28–29 30–31 32–33 34 1.9E Microllam® LVL header and beam sizes: Width: 1¾" Depths: 5 ½", 7¼", 9¼", 9½", 11¼", 117⁄8", 14", 16", 18", and 20" 34–35 35 36 36 37 • Parallam® PSL 38–39 40–41 42–43 44 1.8E Parallam® PSL column and post sizes: 31⁄2" x 31⁄2" 31⁄2" x 51⁄4" 31⁄2" x 7" 51⁄4" x 51⁄4" 2.0E Parallam® PSL header and beam sizes: Widths: 3½", 5¼", and 7" Depths: 9¼", 9½", 11¼", 117⁄8", 14", 16", and 18" 51⁄4" x 7" 7" x 7" For deeper depth Parallam® PSL beams, see the Trus Joist® 2.2E Parallam® PSL Deep Beam guide, # TJ-7001, or contact your Weyerhaeuser representative. Some sizes may not be available in your region. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 2 Structural Solutions Trus Joist® TimberStrand® Laminated Strand Lumber (LSL) •One-piece members reduce labor time •Every piece is straight and strong •Unique properties allow you to drill larger holes through 1.55E TimberStrand® LSL. See Allowable Holes on page 36. TimberStrand® LSL Grade Verification TimberStrand® LSL is available in more than one grade. The product is stamped with its grade information, as shown in the examples below. With 1.55E TimberStrand® LSL, larger holes can be drilled through the beam. Actual stamps shown. Code Evaluations: See ICC ES ESR-1387 and HUD MR 1265 Trus Joist® Microllam® Laminated Veneer Lumber (LVL) • Can easily be built up on site to reduce heavy lifting •Offers reliable and economical solutions for beam and header applications •Manufacturing process minimizes many of the natural inconsistencies found in wood •Available in some regions with a Watershed™ overlay for on-site weather protection Code Evaluations: See ICC ES ESR-1387 and HUD MR 925 Trus Joist® Parallam® Parallel Strand Lumber (PSL) •Allows long spans for open floor plans without intermediate posts or columns • Has warm, unique grain that is perfect for applications with exposed beams • Provides ideal solutions for cantilever and multi-span applications • Solid sections save time on site assembly •Available in some regions with preservative treatment for exterior applications Code Evaluations: See ICC ES ESR-1387 and HUD MR 1303 Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 3 dESIGN PROPERTIES Allowable Design Properties(1) (100% Load Duration) Depth Grade Width Design Property 4 3⁄ 8 " 51 ⁄ 2 " 51 ⁄ 2 " Plank Orientation 1,735 4,085 24 4.5 2,685 5,135 49 5.6 1,780 1,925 20 5.6 71⁄4" 85⁄ 8" 91⁄4" 9 1⁄ 2 " 111⁄4" 117⁄ 8" 14" 16" 18" 20" 7,240 8,635 231 9.4 4,950 3,345 115 5.1 9,905 6,690 231 10.1 5,210 3,435 125 5.2 10,420 6,870 250 10.4 10,520 10,500 415 11.5 7,195 4,070 208 6.2 14,390 8,140 415 12.3 7,975 4,295 244 6.5 15,955 8,590 488 13 10,920 5,065 400 7.7 21,840 10,125 800 15.3 14,090 5,785 597 8.8 28,180 11,575 1,195 17.5 5,600 3,075 115 4.7 5,885 3,160 125 4.8 8,070 3,740 208 5.7 8,925 3,950 244 6.1 12,130 4,655 400 7.1 15,555 5,320 597 8.2 19,375 5,985 851 9.2 23,580 6,650 1,167 10.2 12,415 6,260 231 10.1 18,625 9,390 346 15.2 24,830 12,520 462 20.2 13,055 6,430 250 10.4 19,585 9,645 375 15.6 26,115 12,855 500 20.8 17,970 7,615 415 12.3 26,955 11,420 623 18.5 35,940 15,225 831 24.6 19,900 8,035 488 13.0 29,855 12,055 733 19.5 39,805 16,070 977 26.0 27,160 9,475 800 15.3 40,740 14,210 1,201 23.0 54,325 18,945 1,601 30.6 34,955 10,825 1,195 17.5 52,430 16,240 1,792 26.3 69,905 21,655 2,389 35.0 43,665 12,180 1,701 19.7 65,495 18,270 2,552 29.5 87,325 24,360 3,402 39.4 TimberStrand ® LSL 1.3E 3 1⁄ 2 " 13 ⁄4" 1.55E 3 1⁄ 2 " Moment (ft-lbs) Shear (lbs) Moment of Inertia (in. 4) Weight (plf) Moment (ft-lbs) Shear (lbs) Moment of Inertia (in. 4) Weight (plf) Moment (ft-lbs) Shear (lbs) Moment of Inertia (in. 4) Weight (plf) 4,550 6,765 111 7.4 6,335 8,050 187 8.8 Microllam ® LVL 1.9E 13 ⁄4" Moment (ft-lbs) Shear (lbs) Moment of Inertia (in. 4) Weight (plf) 2,125 1,830 24 2.8 3,555 2,410 56 3.7 Parallam ® PSL 3 1⁄ 2 " 2.0E 51⁄4" 7" Moment (ft-lbs) Shear (lbs) Moment of Inertia (in. 4) Weight (plf) Moment (ft-lbs) Shear (lbs) Moment of Inertia (in. 4) Weight (plf) Moment (ft-lbs) Shear (lbs) Moment of Inertia (in. 4) Weight (plf) (1) For product in beam orientation, unless otherwise noted. Some sizes may not be available in your region. Product Storage Protect product from sun and water om oist.c 58 TrusJ 53.83 888.4 m t.co 8 Jois Trus.453.835 t.com8 Jois .835 Trus.453 888 888 CAUTION: Wrap is slippery when wet or icy .com Joist8358 Trus453. 888. m t.co 8 Jois.835 Trus.453 com ist. 58 sJo .83 Tru 53 888 8.4 88 Use support blocks at 10' on-center to keep bundles out of mud and water m ist.co58 sJo .83 Tru 53 8.4 88 Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 4 Design Properties Design Stresses(1) (100% Load Duration) Orientation G Shear Modulus of Elasticity (psi) E Modulus of Elasticity (psi) E min Adjusted Modulus of Elasticity (2) (psi) 1.55E Beam/Column Plank Beam 81,250 81,250 96,875 1.3 x 106 1.3 x 106 1.55 x 106 660,750 660,750 787,815 1.9E Beam 118,750 1.9 x 106 965,710 1.8E 2.0E Column Beam 112,500 125,000 1.8 x 106 2.0 x 106 914,880 1,016,535 Grade 1.3E Fb Flexural Stress (3) (psi) TimberStrand ® LSL 1,700 1,900(8) 2,325 Microllam ® LVL 2,600 Parallam ® PSL 2,400(10) 2,900 (1) Unless otherwise noted, adjustment to the design stresses for duration of load are permitted in accordance with the applicable code. (2) Reference modulus of elasticity for beam stability and column stability calculations, per NDS® 2005. (3) F or 12" depth. For other depths, multiply Fb by the appropriate factor as follows: – For [ ] LVL, multiply by [ ] PSL, multiply by [ ] 12 0.092 d 12 0.136 d 12 0.111 d – For Parallam® (4) Ft has been adjusted to reflect the volume effects for most standard applications. General Assumptions for Trus Joist® Beams ■ ■ 1,400 1,400 2,050 400 150 310(9) 0.50(7) 0.50(7) 0.50(7) 1,555 750 2,510 285 0.50 1,755 2,025 425(10) 750 2,500 2,900(11) 190(10) 290 0.50 0.50 Beam Orientation Bearing lengths are based on each product’s bearing stress for applicable grade and orientation. All members 71⁄4" and less in depth are restricted to a maximum deflection of 5⁄16". Beams that are 13⁄4" x 16" and deeper require multiple plies. ■ camber. No ■ 680 435 800 ■ SG Equivalent Specific Gravity (6) 1,075 1,075 1,070(9) Lateral support is required at bearing and along the span at 24" on-center, maximum. ■ ■ Fcll Fv Fc⊥ Horizontal Compression Compression Parallel Shear Parallel Perpendicular to Grain to Grain to Grain (5) (psi) (psi) (psi) (5) Fc⊥ may not be increased for duration of load. (6) F or lateral connection design only. (7) S pecific gravity of 0.58 may be used for bolts installed perpendicular to face and loaded perpendicular to grain. (8) V alues are for thickness up to 31⁄2". (9) Values account for large hole capabilities. See Allowable Holes on page 36. (10) Values are for plank orientation. (11) For column applications, use Fcll of 500 psi. – For TimberStrand® LSL, multiply by Microllam® Ft Tension Stress (4) (psi) Beams and columns must remain straight to within 5L2⁄4608 (in.) of true alignment. L is the unrestrained length of the member in feet. Column Orientation Tables on pages 8–15 include load reductions applied in accordance with code. For applications not covered in this brochure, contact your Weyerhaeuser representative. See pages 38 and 39 for multiple-member beam connections. TimberStrand ® LSL, Microllam ® LVL, and untreated Parallam ® PSL are intended for dry-use applications Plank Orientation Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 5 SIZING TABLES How to Use This Table 1.Determine Header Condition. 2.Locate Rough Opening. 3.Determine loading and House Depth. 4.Select TimberStrand® LSL header depth. Note: Bold italic indicates that a 31⁄2" x 51⁄2" TimberStrand® LSL header can be installed in plank orientation in a 2x6 wall. Also see General Notes on page 7. 1.3E TimberStrand LSL ® 31⁄2" Wide 1.3E TimberStrand® LSL Window and Door Headers Header Condition Roof Only House Depth Floor – One Story Roof Plus One Story (Bearing) Rough Opening 3'-2" 3'-8" 4'-2" 4'-8" 5'-2" 5'-8" 6'-2" 6'-8" 7'-2" 8'-2" 9'-2" 3'-2" 3'-8" 4'-2" 4'-8" 5'-2" 5'-8" 6'-2" 6'-8" 7'-2" 8'-2" 9'-2" 3'-2" 3'-8" 4'-2" 4'-8" 5'-2" 5'-8" 6'-2" 6'-8" 7'-2" 8'-2" 9'-2" Non-Snow Area 125% Roof Load = 20LL + 15DL Floor Load = 40LL + 12DL House Depth 24' 28' 32' 4 3⁄8" 4 3⁄8" 4 3⁄8" 4 3⁄8" 4 3⁄8" 4 3⁄8" 4 3⁄8" 4 3⁄8" 4 3⁄8" 4 3 ⁄ 8" 51⁄ 2" 4 3⁄8" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 85 ⁄ 8" 85 ⁄ 8" 85 ⁄ 8" 85 ⁄ 8" 85 ⁄ 8" 91 ⁄4" 4 3⁄8" 4 3⁄8" 4 3⁄8" 4 3 ⁄ 8" 51⁄ 2" 4 3⁄8" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 71 ⁄4" 51⁄ 2" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 85 ⁄ 8" 71 ⁄4" 85 ⁄ 8" 85 ⁄ 8" 71 ⁄4" 85 ⁄ 8" 91 ⁄4"(2) 85 ⁄ 8" 91 ⁄4" 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 4 3⁄8" 4 3⁄8" 4 3⁄8" 4 3 ⁄ 8" 4 3 ⁄ 8" 4 3⁄8" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 85 ⁄ 8" 85 ⁄ 8" 85 ⁄ 8" 85⁄8"(2) 85 ⁄ 8" 85⁄8"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) Roof Load = 30LL + 15DL Floor Load = 40LL + 12DL House Depth 24' 28' 32' 4 3⁄8" 4 3⁄8" 4 3⁄8" 4 3⁄8" 4 3⁄8" 4 3⁄8" 4 3⁄8" 4 3 ⁄ 8" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 85 ⁄ 8" 85 ⁄ 8" 85 ⁄ 8" 85 ⁄ 8" 85 ⁄ 8" 1 1 9 ⁄4" 9 ⁄4" 111 ⁄4"(2) 4 3⁄8" 4 3⁄8" 4 3⁄8" 4 3⁄8" 4 3 ⁄ 8" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 85 ⁄ 8" 71 ⁄4" 85 ⁄ 8" 85 ⁄ 8" 85 ⁄ 8" 85 ⁄ 8" 91 ⁄4"(2) 91 ⁄4" 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 4 3⁄8" 4 3⁄8" 4 3 ⁄ 8" 4 3 ⁄ 8" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄2" 51⁄ 2" 51⁄2" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 85⁄8"(2)` 71 ⁄4" 85⁄8"(2) 85⁄8"(2) 85 ⁄ 8" 85⁄8"(2) 91 ⁄4"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) Snow Area 115% Roof Load = 40LL + 15DL Floor Load = 40LL + 12DL House Depth 24' 28' 32' 4 3⁄8" 4 3⁄8" 4 3⁄8" 4 3⁄8" 4 3 ⁄ 8" 4 3 ⁄ 8" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 85 ⁄ 8" 85 ⁄ 8" 85 ⁄ 8" 85 ⁄ 8" 85⁄8"(2) 85 ⁄ 8" 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 4 3⁄8" 4 3⁄8" 4 3⁄8" 4 3⁄8" 4 3 ⁄ 8" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 85 ⁄ 8" 71 ⁄4" 85 ⁄ 8" 85 ⁄ 8" 85 ⁄ 8" 85 ⁄ 8" 91 ⁄4"(2) 91 ⁄4" 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 4 3⁄8" 4 3 ⁄ 8" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4"(2) 71 ⁄4" 71 ⁄4" 85⁄8"(2) 71 ⁄4" 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 91 ⁄4"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) Symbol represents location of TimberStrand® LSL header. Symbol represents supporting beam or structural bearing wall located at center of house, below floor. ( )Symbol represents minimum number of 2x_ trimmers required at end of header. ■ See Bearing Requirements on page 7 for bearing length requirements at continuous-span supports. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 6 Roof Load = 55LL + 15DL Floor Load = 40LL + 12DL House Depth 24' 28' 32' 4 3⁄8" 4 3⁄8" 4 3 ⁄ 8" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 85⁄8"(2) 85 ⁄ 8" 85⁄8"(2) 85⁄8"(2) 85 ⁄ 8" 85⁄8"(2) 91 ⁄4"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 4 3⁄8" 4 3⁄8" 4 3⁄8" 4 3⁄8" 4 3 ⁄ 8" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4" 85 ⁄ 8" 71 ⁄4" 85 ⁄ 8" 85 ⁄ 8" 85 ⁄ 8" 85 ⁄ 8" 91 ⁄4"(2) 91 ⁄4" 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 4 3 ⁄ 8" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4"(2) 71 ⁄4" 71 ⁄4"(2) 85⁄8"(2) 71 ⁄4"(2) 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 91 ⁄4"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) SIZING TABLES General Notes Bearing Requirements Tables are based on: – Uniform loads. –More restrictive of simple or continuous span. Ratio of short span to long span should be greater than 0.4 to prevent uplift. – Roof truss framing with 24" soffits. – Exterior wall weights of 80 plf, interior 60 plf. –Deflection criteria of L/360 live load and L/240 total load. ■ ■ Tables assume minimum header support to be one trimmer (11⁄2") at each end and 41⁄2" at continuous-span supports. In Sizing Tables on pages 6 and 7: (2)Indicates minimum header support to be two trimmers (3") at each end and 71⁄2" at continuous-span supports. (3)Indicates minimum header support to be three trimmers (41⁄2") at each end and 111⁄4" at continuous-span supports. Tables do not consider attic loads acting concurrently with roof or snow loads. Also see How to Use This Table on page 6 and General Assumptions on page 5. For additional bearing information, see pages 34 and 36. 31⁄2" Wide 1.3E TimberStrand® LSL Window and Door Headers continued Header Condition Roof Plus One Story (No bearing) House Depth Floor – Two Stories Roof Plus Two Stories (Bearing) Roof Plus Two Stories (No Bearing) Rough Opening 3'-2" 3'-8" 4'-2" 4'-8" 5'-2" 5'-8" 6'-2" 6'-8" 7'-2" 8'-2" 3'-2" 3'-8" 4'-2" 4'-8" 5'-2" 5'-8" 6'-2" 3'-2" 3'-8" 4'-2" 4'-8" 5'-2" 5'-8" 6'-2" 6'-8" 7'-2" 3'-2" 3'-8" 4'-2" 4'-8" 5'-2" 5'-8" 6'-2" Non-Snow Area 125% Roof Load = 20LL + 15DL Floor Load = 40LL + 12DL House Depth 24' 28' 32' 4 3⁄8" 4 3 ⁄ 8" 4 3 ⁄ 8" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4"(2) 71 ⁄4" 71 ⁄4"(2) 71 ⁄4"(2) 71 ⁄4" 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 91 ⁄4"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 51⁄ 2" 51⁄ 2" 71 ⁄4" 71 ⁄4"(2) 71 ⁄4"(2) 71 ⁄4" 71 ⁄4" 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 91 ⁄4"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 4 3⁄8" 4 3 ⁄ 8" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4"(2) 71 ⁄4" 71 ⁄4"(2) 85⁄8"(2) 71 ⁄4"(2) 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 91 ⁄4"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 51⁄ 2" 71 ⁄4"(2) 71 ⁄4"(2) 71 ⁄4"(2) 71 ⁄4"(2) 71 ⁄4"(2) 71 ⁄4"(2) 71 ⁄4"(2) 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 91 ⁄4"(2) 91 ⁄4"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(3) 111 ⁄4"(2) 111 ⁄4"(3) 111 ⁄4"(3) Roof Load = 30LL + 15DL Floor Load = 40LL + 12DL House Depth 24' 28' 32' 4 3 ⁄ 8" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 71 ⁄4" 51⁄ 2" 71 ⁄4" 71 ⁄4"(2) 71 ⁄4" 71 ⁄4"(2) 71 ⁄4"(2) 71 ⁄4" 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 91 ⁄4"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 51⁄ 2" 51⁄ 2" 71 ⁄4" 71 ⁄4" 71 ⁄4"(2) 71 ⁄4"(2) 71 ⁄4" 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 91 ⁄4"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 4 3 ⁄ 8" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 71 ⁄4" 71 ⁄4" 71 ⁄4" 71 ⁄4"(2) 71 ⁄4" 71 ⁄4"(2) 85⁄8"(2) 71 ⁄4"(2) 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 91 ⁄4"(2) 91 ⁄4"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 51⁄ 2" 71 ⁄4"(2) 71 ⁄4"(2) 71 ⁄4"(2) 71 ⁄4"(2) 71 ⁄4"(2) 71 ⁄4"(2) 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 91 ⁄4"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(3) 111 ⁄4"(2) 111 ⁄4"(3) 111 ⁄4"(3) 111 ⁄4"(2) Snow Area 115% Roof Load = 40LL + 15DL Floor Load = 40LL + 12DL House Depth 24' 28' 32' 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 51⁄ 2" 71 ⁄4"(2) 71 ⁄4" 71 ⁄4"(2) 71 ⁄4"(2) 71 ⁄4" 71 ⁄4"(2) 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 51⁄ 2" 71 ⁄4" 71 ⁄4" 85⁄8"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 51⁄ 2" 51⁄ 2" 71 ⁄4" 71 ⁄4"(2) 85⁄8"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 71 ⁄4"(2) 71 ⁄4"(2) 85⁄8"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(3) 51⁄ 2" 71 ⁄4"(2) 85⁄8"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 51⁄ 2" 71 ⁄4" 71 ⁄4"(2) 85⁄8"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 71 ⁄4" 71 ⁄4"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 71 ⁄4"(2) 71 ⁄4"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(3) 71 ⁄4"(2) 85⁄8"(2) 85⁄8"(2) 111 ⁄4"(3) 111 ⁄4"(3) 51⁄ 2" 71 ⁄4"(2) 71 ⁄4"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) Symbol represents location of TimberStrand® LSL header. Symbol represents supporting beam or structural bearing wall located at center of house, below floor. ( )Symbol represents minimum number of 2x_ trimmers required at end of header. ■ See Bearing Requirements above for bearing length requirements at continuous-span supports. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 7 Roof Load = 55LL + 15DL Floor Load = 40LL + 12DL House Depth 24' 28' 32' 51⁄ 2" 51⁄ 2" 71 ⁄4"(2) 51⁄ 2" 71 ⁄4"(2) 71 ⁄4"(2) 71 ⁄4"(2) 71 ⁄4"(2) 85⁄8"(2) 71 ⁄4"(2) 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 85⁄8"(2) 91 ⁄4"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(3) 111 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 51⁄ 2" 71 ⁄4" 71 ⁄4" 85⁄8"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 51⁄ 2" 71 ⁄4" 71 ⁄4"(2) 85⁄8"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 51⁄ 2" 71 ⁄4"(2) 85⁄8"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 51⁄ 2" 71 ⁄4"(2) 71 ⁄4"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 71 ⁄4" 71 ⁄4"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) 111 ⁄4"(2) 71 ⁄4"(2) 71 ⁄4"(2) 85⁄8"(2) 85⁄8"(2) 111 ⁄4"(2) 111 ⁄4"(3) 71 ⁄4"(2) 85⁄8"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(3) 71 ⁄4"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(3) 111 ⁄4"(3) 71 ⁄4"(2) 71 ⁄4"(2) 85⁄8"(2) 85⁄8"(2) 91 ⁄4"(2) 111 ⁄4"(2) SIZING TABLES How to Use This Table 1.Determine appropriate Roof Load and House Width. 2.Locate Rough Opening. 3.Select header size and material. Weyerhaeuser offers 1.55E TimberStrand® LSL pre-cut garage door headers in selected regions. Call 1-888-453-8358 to determine availability. ■ Also see General Notes on page 9. ew us Ho Rough g openin idt h Rough g openin Headers Supporting Roof Roof Load (PSF) House Width 30' 36' 13/4" x 14"(3) 31/2" x 91/4" 24' 20LL + 15DL 30' 36' Non-Snow Area 125% 24' 20LL + 20DL 30' 36' 24' 25LL + 15DL 30' 36' 24' Snow Area 115% 30LL + 15DL 30' 36' 24' 40LL + 15DL T 1.55E TimberStrand® LSL Rough Opening 8' 13/4" x 91/4" 31/2" x 71/4" 31/2" x 91/4" 13/4" x 91/4" 31/2" x 71/4" 31/2" x 91/4" 13/4" x 91/4" 31/2" x 91/4" 51/4" x 71/4" 13/4" x 91/4" 31/2" x 71/4" 31/2" x 91/4" 13/4" x 91/4" 31/2" x 91/4" 51/4" x 71/4" 13/4" x 91/4" 13/4" x 111/4" 31/2" x 91/4" 13/4" x 91/4" 31/2" x 71/4" 31/2" x 91/4" 13/4" x 91/2" 31/2" x 91/4" 51/4" x 71/4" 13/4" x 111/4" 31/2" x 91/4" 51/4" x 71/4" 13/4" x 91/4" 31/2" x 91/4" 51/4" x 71/4" 13/4" x 91/2" 13/4" x 111/4" 31/2" x 91/4" 13/4" x 111/4" 31/2" x 91/4" 51/4" x 71/4" 13/4" x 91/2" 13/4" x 111/4" 31/2" x 91/4" 13/4" x 111/4"(3) 31/2" x 91/4" T M M T M T M M T M T M T M M T M M T M T M T M M M T M T M T M M T M T M T M M T M T M M T M T M M M T M T M T M T M M M T M T M T M T M P P P P P P P P P P P P P P T M T M P M 1.9E Microllam® LVL 9'-3" 13/4" x 91/4" 31/2" x 91/4" 51/4" x 71/4" 13/4" x 91/4" 13/4" x 111/4" 31/2" x 91/4" 13/4" x 111/4" 31/2" x 91/4" T M T M P M M T M T M P T M T M P 13/4" x 91/4" 13/4" x 91/2" 31/2" x 91/4" 13/4" x 111/4" 31/2" x 91/4" T T T T 13/4" x 111/4" 13/4" x 117⁄ 8" 31/2" x 91/4" 13/4" x 91/4" 13/4" x 111/4" 31/2" x 91/4" 13/4" x 111/4" 31/2" x 91/4" M T M T M P M T M T M P T M T M P 13/4" x 111/4" 13/4" x 117⁄ 8" 31/2" x 91/4" 13/4" x 111/4" 31/2" x 91/4" T T T T M M M P M M P 13/4" x 111/4" 13/4" x 117⁄ 8" 31/2" x 91/4" 13/4" x 14"(3) 31/2" x 91/4" T T T T M M M P M M P 13/4" x 111/4" 13/4" x 117⁄ 8" 31/2" x 91/4" 13/4" x 14"(3) 31/2" x 91/4" T T T T M M M P M M P 31/2" x 91/4" 31/2" x 111/4" 51/4" x 91/4" M P T M P T M P M M M P M M P 10' 13/4" x 91/4" 13/4" x 111/4" 31/2" x 91/4" 13/4" x 111/4" 31/2" x 91/4" T T T T M M M P M M P 13/4" x 111/4" 13/4" x 117⁄ 8" 31/2" x 91/4" 13/4" x 111/4" 31/2" x 91/4" T T T T M M M P M M P 13/4" x 111/4" 13/4" x 117⁄ 8" 31/2" x 91/4" 13/4" x 117⁄ 8"(3) 13/4" x 14"(3) 31/2" x 91/4" 13/4" x 111/4" 31/2" x 91/4" M T M T M P M T M T M P T M T M P M T M T M P T M M P T M P T M M P T M P M T M T M P T M M P T M P T M P T M P T M T M P T M P M M P T M P T M P T M P 13/4" x 111/4" 13/4" x 117⁄ 8" 31/2" x 91/4" 13/4" x 14"(3) 31/2" x 91/4" T T T T M M M P M M P 13/4" x 14" 31/2" x 91/2" 51/4" x 91/4" 13/4" x 14"(3) 31/2" x 91/2" 31/2" x 111/4" 31/2" x 111/4" 51/4" x 91/4" 13/4" x 111/4" 13/4" x 117⁄ 8" 31/2" x 91/4" 13/4" x 14"(3) 31/2" x 91/4" T T T T M M M P M M P 13/4" x 14"(3) 31/2" x 91/4" 31/2" x 111/4" 31/2" x 111/4" 51/4" x 91/4" T M M T M T M T M P P P P 13/4" x 14"(3) 31/2" x 91/2" 51/4" x 91/4" 13/4" x 14"(3) 31/2" x 91/4" T T T T T M M P M P M M P 31/2" x 117⁄ 8" 51/4" x 91/4" 51/4" x 111/4" 31/2" x 111/4" 51/4" x 91/4" T M M T M T M T M P P P P P 13/4" x 14"(3) 31/2" x 91/4" 31/2" x 111/4" 31/2" x 91/2" 31/2" x 111/4" 51/4" x 91/4" M M P T M P P T M P T M P 31/2" x 117⁄ 8" 51/4" x 91/4" 51/4" x 111/4" 31/2" x 117⁄ 8" 31/2" x 14" 51/4" x 91/2" T M P M P T M P P T M P P P 2.0E Parallam® PSL Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 8 12' 13/4" x 111/4" 13/4" x 117⁄ 8" 31/2" x 91/4" 13/4" x 14" 31/2" x 91/4" 31/2" x 111/4" 13/4" x 14"(3) 31/2" x 91/2" 31/2" x 111/4" 13/4" x 117⁄ 8" 13/4" x 14" 31/2" x 91/2" 13/4" x 14"(3) 31/2" x 91/2" 31/2" x 111/4" 31/2" x 111/4" 51/4" x 91/4" SIZING TABLES General Notes Bearing Requirements Table is based on: – Uniform loads. –More restrictive of simple or continuous span. Ratio of short span to long span should be 0.4 or greater to prevent uplift. – Roof truss framing with 24" soffits. – Deflection criteria of L/240 live load and L/180 total load. ■ ■ Minimum header support to be two trimmers (3") at each end and 71⁄2" at continuous-span supports. In Sizing Tables on pages 8 and 9: (3) Indicates requirement of three trimmers (41⁄2") at each end and 111⁄4" at continuous-span supports. Tables do not consider attic loads acting concurrently with roof or snow loads. Also see How to Use This Table on page 8 and General Assumptions on page 5. Headers Supporting Roof continued Roof Load (PSF) House Width 24' 20LL + 15DL 30' 36' Non-Snow Area 125% 24' 20LL + 20DL 30' 36' 24' 25LL + 15DL 30' 36' 24' Snow Area 115% 30LL + 15DL 30' 36' 24' 40LL + 15DL 30' 36' T 1.55E TimberStrand® LSL 14' 13/4" x 14" 31/2" x 91/2" 31/2" x 111/4" 31/2" x 111/4" 51/4" x 91/4" T M P T M P T M P M P 31/2" x 117⁄ 8" 51/4" x 91/2" 51/4" x 111/4" 13/4" x 14"(3) 31/2" x 111/4" 51/4" x 91/2" 31/2" x 117⁄ 8" 51/4" x 91/2" 51/4" x 111/4" 31/2" x 117⁄ 8" 31/2" x 14" 51/4" x 111/4" 31/2" x 111/4" 51/4" x 91/4" 51/4" x 91/2" 31/2" x 117⁄ 8" 51/4" x 91/2" 51/4" x 111/4" 31/2" x 117⁄ 8" 31/2" x 14" 51/4" x 111/4" 31/2" x 117⁄ 8" 51/4" x 91/4" 51/4" x 111/4" 31/2" x 117⁄ 8" 31/2" x 14" 51/4" x 111/4" 31/2" x 14" 51/4" x 111/4" T M M T M M T M T M T M M T M M T M T M T M M T M T M M T M 31/2" x 117⁄ 8" 31/2" x 14" 51/4" x 111/4" 31/2" x 14" 51/4" x 111/4" 51/4" x 117⁄ 8" 31/2" x 14"(3) 31/2" x 16"(3) 51/4" x 117⁄ 8" M P T M P T M P T M P M P T M P P T M P M P T M T M T M M T M M T M T M T M T M P P P P P P P P P P P P P P P P P P P P P P P P P P P P M 1.9E Microllam® LVL Rough Opening 16'-3" 31/2" x 117⁄ 8" M 31/2" x 14" T M 51/4" x 111/4" T M 31/2" x 117⁄ 8" 31/2" x 14" T M 51/4" x 111/4" T M 31/2" x 14" T M 51/4" x 111/4" M 51/4" x 117⁄ 8" T M 31/2" x 117⁄ 8" M 31/2" x 14" T M 51/4" x 111/4" T M 31/2" x 14" T M 51/4" x 111/4" M 51/4" x 117⁄ 8" T M 31/2" x 14" M 31/2" x 16" T M 51/4" x 117⁄ 8" M 31/2" x 117⁄ 8" M 31/2" x 14" T M 51/4" x 111/4" T M 31/2" x 14" T M 51/4" x 111/4" M 51/4" x 117⁄ 8" T M 31/2" x 14" M 31/2" x 16" T M 51/4" x 117⁄ 8" M 31/2" x 14" T M 51/4" x 111/4" M 51/4" x 117⁄ 8" T M 31/2" x 14" M 31/2" x 16" T M 51/4" x 117⁄ 8" M 31/2" x 14" 31/2" x 16" T M 51/4" x 14" T M 31/2" x 14" M 31/2" x 16" T M 51/4" x 117⁄ 8" M 31/2" x 16"(3) M 51/4" x 14" T M 31/2" x 16"(3) 31/2" x 18"(3) 51/4" x 14" P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P M P M P 18'-3" 31/2" x 14" 51/4" x 111/4" 51/4" x 117⁄ 8" 31/2" x 14" 31/2" x 16" 51/4" x 117⁄ 8" 31/2" x 16" 51/4" x 14" T M M T M M T M M T M T M 31/2" x 14" 31/2" x 16" 51/4" x 117⁄ 8" 31/2" x 14" 31/2" x 16" 51/4" x 14" 31/2" x 16" 51/4" x 14" 51/4" x 16" 31/2" x 14" 31/2" x 16" 51/4" x 117⁄ 8" 31/2" x 14" 31/2" x 16" 51/4" x 14" 31/2" x 16" 51/4" x 14" 51/4" x 16" 31/2" x 14" 31/2" x 16" 51/4" x 117⁄ 8" 31/2" x 16" 51/4" x 14" M P T M P M P P T M P T M P M P M P T M P M P T M P M P P T M P T M P M P M P T M P M P T M P P M P T M P 31/2" x 16"(3) 31/2" x 18"(3) 51/4" x 14" 31/2" x 16" 51/4" x 14" M M M T M 31/2" x 18"(3) 51/4" x 14" 51/4" x 16" 31/2" x 18"(3) 31/2" x 20"(3) 51/4" x 16" M P M P T M P P M T M P P 2.0E Parallam® PSL Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 9 P P P P P P P P P P P P P SIZING TABLES How to Use This Table Colu spac mn ing 1.Determine appropriate Roof Load and House Width. 2.Locate Column Spacing. 3. Select beam size and material. Also see General Notes on page 11. House width Ridge Beams Roof Load (PSF) House Width Column Spacing 10' 31/2" x 91/4" T M P 12' 31/2" x 91/4" T M P 24' 20LL + 15DL 31/2" x 91/4" T M P 31/2" x 91/4" T M P 31/2" x 91/4" T M P 31/2" x 91/4" T M P 31/2" x 91/4" 31/2" x 111/4" 51/4" x 91/4" 31/2" x 91/4" M P T M P T M P T M P 31/2" x 91/4" T M P 31/2" x 91/4" T M P 31/2" x 91/4" T M P 31/2" x 91/4" 31/2" x 91/2" 51/4" x 91/4" 31/2" x 91/2" 31/2" x 111/4" 51/4" x 91/4" 31/2" x 91/4" M P T M P T M P M P T M P T M P T M P 31/2" x 91/4" T M P 31/2" x 91/4" T M P 31/2" x 91/4" T M P 31/2" x 91/4" 31/2" x 91/2" 51/4" x 91/4" 31/2" x 91/2" 31/2" x 111/4" 51/4" x 91/4" 31/2" x 91/4" M P T M P T M P M P T M P T M P T M P 31/2" x 91/4" T M P 31/2" x 91/4" 31/2" x 111/4" 51/4" x 91/4" 31/2" x 111/4" 51/4" x 91/4" T T T T M M M M M P P P P P 31/2" x 91/4" 31/2" x 111/4" 51/4" x 91/4" 31/2" x 111/4" 51/4" x 91/4" T T T T M M M M M P P P P P 31/2" x 117⁄ 8" 51/4" x 91/4" 51/4" x 111/4" T M P M P T M P 30' 36' Non-Snow Area 125% 24' 20LL + 20DL 30' 36' 24' 25LL + 15DL 30' 36' 24' Snow Area 115% 30LL + 15DL 30' 31/2" x 91/4" T M P 31/2" x 91/4" T M P 36' 24' 40LL + 15DL 36' T 1.55E TimberStrand® LSL 31/2" x 91/4" T M P 31/2" x 91/4" 31/2" x 111/4" 51/4" x 91/4" M P T M P T M P 30' M 1.9E Microllam® LVL 14' 31/2" x 91/4" 31/2" x 111/4" 51/4" x 91/4" 31/2" x 111/4" 51/4" x 91/4" T T T T 31/2" x 111/4" 51/4" x 91/4" T M P M P 31/2" x 91/2" 31/2" x 111/4" 51/4" x 91/4" 31/2" x 111/4" 51/4" x 91/4" P T M P T M P T M P M P 31/2" x 117⁄ 8" 51/4" x 91/2" 51/4" x 111/4" 31/2" x 91/2" 31/2" x 111/4" 51/4" x 91/4" 31/2" x 111/4" 51/4" x 91/4" T M P P T M P P T M P T M P T M P M P 31/2" x 117⁄ 8" 51/4" x 91/2" 51/4" x 111/4" 31/2" x 111/4" 51/4" x 91/4" 51/4" x 91/2" 31/2" x 117⁄ 8" 51/4" x 91/2" 51/4" x 111/4" 31/2" x 117⁄ 8" 31/2" x 14" 51/4" x 111/4" 31/2" x 117⁄ 8" 51/4" x 91/4" 51/4" x 111/4" 31/2" x 117⁄ 8" 31/2" x 14" 51/4" x 111/4" 31/2" x 14" 51/4" x 111/4" 51/4" x 117⁄ 8" T M P P T M P T M P M P T M P T M P M P T M P M P T M P T M P T M P M P T M P M P T M P T M P T M P M P T M P M M M M M P P P P P P 2.0E Parallam® PSL Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 10 16' 31/2" x 111/4" 51/4" x 91/4" T M P M P 31/2" x 111/4" 31/2" x 14" 51/4" x 111/4" 31/2" x 117⁄ 8" 31/2" x 14" 51/4" x 111/4" 31/2" x 117⁄ 8" 51/4" x 91/2" 51/4" x 111/4" 31/2" x 117⁄ 8" 31/2" x 14" 51/4" x 111/4" 31/2" x 14" 51/4" x 111/4" 51/4" x 117⁄ 8" 31/2" x 117⁄ 8" 51/4" x 91/2" 51/4" x 111/4" 31/2" x 117⁄ 8" 31/2" x 14" 51/4" x 111/4" 31/2" x 14" 51/4" x 111/4" 51/4" x 117⁄ 8" 31/2" x 117⁄ 8" 31/2" x 14" 51/4" x 111/4" 31/2" x 14" 51/4" x 111/4" 51/4" x 117⁄ 8" 31/2" x 14" 31/2" x 16" 51/4" x 117⁄ 8" 31/2" x 14" 51/4" x 111/4" 51/4" x 117⁄ 8" 31/2" x 14" 31/2" x 16" 51/4" x 117⁄ 8" 31/2" x 16"(3) 51/4" x 14" M P T M P T M P P T M P T M P T M P M P T M P M P T M P T M P T M P M P T M P T M P M P T M P M P T M P T M P T M P M P T M P M P T M P T M P T M P M P T M P M P T M P M P T M P M P T M P M P T M P M P T M P T M P SIZING TABLES General Notes Bearing Requirements Table is based on: – Uniform loads. –More restrictive of simple or continuous span. Ratio of short span to long span should be 0.4 or greater to prevent uplift. –Deflection criteria of L/240 live load and L/180 total load. ■ Minimum beam supports to be two trimmers (3") at each end and 71⁄2" at continuous-span supports. In Sizing Tables on pages 10 and 11: (3) Indicates requirement of three trimmers (41⁄2") at each end and 111⁄4" at continuous-span supports. Also see How to Use This Table on page 10 and General Assumptions on page 5. Ridge Beams continued Roof Load (PSF) House Width 24' 20LL + 15DL 30' 36' Non-Snow Area 125% 24' 20LL + 20DL 30' 36' 24' 25LL + 15DL 30' 36' 24' Snow Area 115% 30LL + 15DL 30' 36' 24' 40LL + 15DL 30' 36' T 1.55E TimberStrand® LSL Column Spacing 18' 31/2" x 117⁄ 8" 31/2" x 14" 51/4" x 111/4" 31/2" x 14" 51/4" x 111/4" 51/4" x 117⁄ 8" 31/2" x 14" 31/2" x 16" 51/4" x 117⁄ 8" 31/2" x 14" 51/4" x 111/4" 51/4" x 117⁄ 8" 31/2" x 14" 31/2" x 16" 51/4" x 117⁄ 8" 31/2" x 14" 31/2" x 16" 51/4" x 14" 31/2" x 14" 51/4" x 111/4" 51/4" x 117⁄ 8" 31/2" x 14" 31/2" x 16" 51/4" x 117⁄ 8" 31/2" x 14" 31/2" x 16" 51/4" x 14" 31/2" x 14" 51/4" x 111/4" 31/2" x 14" 31/2" x 16" 51/4" x 117⁄ 8" 31/2" x 16" 51/4" x 14" T T T T T T T T M M M M M M M M M M M M M M M T M T M T M M T M M T M M T M T M T M M P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P T M P P M P T M P 31/2" x 14" 31/2" x 16" 51/4" x 117⁄ 8" 31/2" x 16" 51/4" x 14" M P T M P P M P T M P 31/2" x 18"(3) 51/4" x 14" 51/4" x 16" M P M P T M P M 1.9E Microllam® LVL 20' 31/2" x 14" 51/4" x 111/4" 51/4" x 117⁄ 8" 31/2" x 14" 31/2" x 16" 51/4" x 14" 31/2" x 16" 51/4" x 14" T M P P M P P T M P T M P M P T M P 31/2" x 14" 31/2" x 16" 51/4" x 117⁄ 8" 31/2" x 16" 51/4" x 14" M P T M P P T M P T M P 31/2" x 16" 51/4" x 14" 51/4" x 16" 31/2" x 14" 31/2" x 16" 51/4" x 117⁄ 8" 31/2" x 16" 51/4" x 14" M M T M M T M P P P P P P T M P T M P 31/2" x 16" 31/2" x 18" 51/4" x 14" 31/2" x 14" 31/2" x 16" 51/4" x 14" 31/2" x 16" 51/4" x 14" 51/4" x 16" 31/2" x 18"(3) 51/4" x 14" 51/4" x 16" 31/2" x 16" 51/4" x 14" 51/4" x 16" 31/2" x 18"(3) 51/4" x 16" 7" x 14" 31/2" x 20"(3) 51/4" x 16" 7" x 14" P M P M P P M P M P M P M P M P M P P M P M P M P M P M P M P P M M P P T T T T T T 22' 31/2" x 16" 51/4" x 14" 31/2" x 16" 51/4" x 14" 51/4" x 16" 31/2" x 18" 51/4" x 16" 7" x 14" 31/2" x 16" 51/4" x 14" 51/4" x 16" 31/2" x 16" 31/2" x 18" 51/4" x 14" 31/2" x 18"(3) 51/4" x 16" 7" x 14" 31/2" x 16" 51/4" x 14" 51/4" x 16" 31/2" x 16" 31/2" x 18" 51/4" x 14" 31/2" x 18"(3) 31/2" x 20"(3) 51/4" x 16" 31/2" x 16" 51/4" x 14" 51/4" x 16" 31/2" x 18" 51/4" x 16" 7" x 14" 31/2" x 18"(3) 31/2" x 20"(3) 51/4" x 16" 31/2" x 18" 51/4" x 16" 7" x 14" 31/2" x 20"(3) 51/4" x 16" 51/4" x 18" 7" x 16" T M P T M P M M T M M T M M M T M M M M M M T M M M M M M T M M T M P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P M M P M P T M P P M M P M P P P 2.0E Parallam® PSL Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 11 24' 31/2" x 16" 51/4" x 14" 51/4" x 16" 31/2" x 18" 51/4" x 16" 7" x 14" 31/2" x 18" 51/4" x 16" 7" x 14" 31/2" x 18" 51/4" x 16" 7" x 14" 31/2" x 18" 51/4" x 16" 7" x 14" 31/2" x 20"(3) 51/4" x 18" 7" x 16" 31/2" x 18" 51/4" x 16" 7" x 14" 31/2" x 18" 51/4" x 16" 7" x 14" 31/2" x 20"(3) 51/4" x 18" 7" x 16" 31/2" x 18" 51/4" x 16" 7" x 14" 31/2" x 20"(3) 51/4" x 16" 51/4" x 18" 51/4" x 18" 7" x 16" M M T M M T M M M M T M M M P P P P P P P P P P P P P P P M M P P M P T M P P M P M P P M M P P M P T M P P M P M P M P P 31/2" x 18"(3) 31/2" x 20"(3) 51/4" x 16" 51/4" x 18" 7" x 16" P M M P M P P 51/4" x 18"(3) 51/4" x 20"(3) M P SIZING TABLES How to Use This Table 1.Verify that floor loading of 40 psf live load and 12 psf dead load is adequate. 2. Determine appropriate Load and House Width. 3.Locate Rough Opening. 4.Select header size and material. Also see General Notes on page 13. Rough opening 1⁄2 House width maximum House width Headers Supporting Floor and Roof Load (PSF) Roof Load 20LL + 15DL Floor Load 40LL + 12DL House Width 24' T M T M P 30' 13/4" x 117⁄ 8"(3) 31/2" x 91/4" T M T M P 24' 13/4" x 14"(3) 31/2" x 91/2" 51/4" x 91/4" 13/4" x 111/4"(3) 31/2" x 91/4" 30' 13/4" x 14"(3) 31/2" x 91/4" 36' Non-Snow Area 125% Roof Load 20LL + 20DL Floor Load 40LL + 12DL 24' 13/4" x 14"(3) 31/2" x 91/4" 31/2" x 111/4" 13/4" x 111/4"(3) 31/2" x 91/4" 30' 13/4" x 14"(3) 31/2" x 91/4" 36' Roof Load 25LL + 15DL Floor Load 40LL + 12DL 36' 24' Snow Area 115% Roof Load 30LL + 15DL Floor Load 40LL + 12DL 30' 36' 24' Roof Load 40LL + 15DL Floor Load 40LL + 12DL 30' 36' T 1.55E TimberStrand® LSL Rough Opening 8' 13/4" x 111/4" 31/2" x 91/4" 13/4" x 14"(3) 31/2" x 91/4" 31/2" x 111/4" 13/4" x 117⁄ 8"(3) 13/4" x 14"(3) 31/2" x 91/4" 13/4" x 14"(3) 31/2" x 91/4" T T T T T M M P M P M M P T M T M P T M P T M P T M T M P T M T M P T M P T M P T T M T M P T M T M P 31/2" x 91/4" 31/2" x 111/4" 51/4" x 91/4" 13/4" x 14"(3) 31/2" x 91/4" T T T T M M M M M P P P 31/2" x 91/4" 31/2" x 111/4" 51/4" x 91/4" 31/2" x 111/4" 51/4" x 91/4" T T T T M M M M M P P P P P P M 1.9E Microllam® LVL 9'-3" 13/4" x 117⁄ 8"(3) 13/4" x 14"(3) 31/2" x 91/2" 13/4" x 14"(3) 31/2" x 91/2" 31/2" x 111/4" 31/2" x 111/4" 51/4" x 91/4" T T T T T T M M M M M M M M P P P P P 13/4" x 14"(3) 31/2" x 91/4" 31/2" x 111/4" 13/4" x 14"(3) 31/2" x 91/2" 31/2" x 111/4" 31/2" x 111/4" 51/4" x 91/4" T M M P T M P T M P T M P T M P M P 13/4" x 14"(3) 31/2" x 91/4" 31/2" x 111/4" 31/2" x 91/2" 31/2" x 111/4" 51/4" x 91/4" 31/2" x 111/4" 51/4" x 91/4" T M M P T M P P T M P T M P T M P M P 13/4" x 14"(3) 31/2" x 91/4" 31/2" x 111/4" 31/2" x 111/4" 51/4" x 91/4" T M M T M T M T M P P P P 31/2" x 117⁄ 8" 51/4" x 91/4" 51/4" x 111/4" 31/2" x 111/4" 51/4" x 91/4" T M M T M T M T M P P P P P 31/2" x 117⁄ 8" 51/4" x 91/4" 51/4" x 111/4" 31/2" x 117⁄ 8"(3) 31/2" x 14" 51/4" x 91/2" T M M T M M T M P P P P P P 10' 13/4" x 14"(3) 31/2" x 91/2" 31/2" x 111/4" 31/2" x 111/4" 51/4" x 91/4" 51/4" x 91/2" 31/2" x 117⁄ 8" 51/4" x 91/2" 51/4" x 111/4" 13/4" x 14"(3) 31/2" x 111/4" 51/4" x 91/4" 31/2" x 111/4" 51/4" x 91/4" T M M T M T M M T M T M M T M T M T M T M T M M 31/2" x 117⁄ 8" 51/4" x 91/2" 51/4" x 111/4" 13/4" x 14"(3) 31/2" x 111/4" 51/4" x 91/4" 31/2" x 111/4" 51/4" x 91/4" T M P P T M P M T M P T M P T M P M P 31/2" x 117⁄ 8" 51/4" x 91/2" 51/4" x 111/4" 31/2" x 111/4" 51/4" x 91/4" 51/4" x 91/2" 31/2" x 117⁄ 8" 51/4" x 91/2" 51/4" x 111/4" 31/2" x 117⁄ 8" 31/2" x 14" 51/4" x 111/4" 31/2" x 117⁄ 8" 51/4" x 91/4" 51/4" x 111/4" 31/2" x 117⁄ 8" 31/2" x 14" 51/4" x 111/4" 31/2" x 14"(3) 51/4" x 111/4" T M P P T M P T M P M P T M P T M P M P T M P M P T M P T M P T M P M P T M P M P T M P T M P T M P T M P P P P P P P P P P P P P P P 2.0E Parallam® PSL Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 12 12' 31/2" x 117⁄ 8" 31/2" x 14" 51/4" x 111/4" 31/2" x 14" 51/4" x 111/4" 51/4" x 117⁄ 8" 31/2" x 14"(3) 51/4" x 111/4" M P T M P T M P T M P M P T M P T M P M P 31/2" x 117⁄ 8" 31/2" x 14" 51/4" x 111/4" 31/2" x 14" 51/4" x 111/4" 51/4" x 117⁄ 8" 31/2" x 14"(3) 31/2" x 16"(3) 51/4" x 117⁄ 8" 31/2" x 117⁄ 8" 31/2" x 14" 51/4" x 111/4" 31/2" x 14" 51/4" x 111/4" 51/4" x 117⁄ 8" 31/2" x 14"(3) 31/2" x 16"(3) 51/4" x 117⁄ 8" 31/2" x 117⁄ 8" 31/2" x 14" 51/4" x 111/4" 31/2" x 14" 51/4" x 111/4" M P T M P T M P T M P M P T M P M P T M P M P M P T M P T M P T M P M P T M P M P T M P M P P T M P T M P T M P M P 31/2" x 14"(3) 31/2" x 16"(3) 51/4" x 117⁄ 8" 31/2" x 14" 51/4" x 111/4" 51/4" x 117⁄ 8" 31/2" x 14"(3) 31/2" x 16"(3) 51/4" x 117⁄ 8" 31/2" x 16"(3) 51/4" x 14" T M M T M M T M M T M M T M T M P P P P P P P P P P P SIZING TABLES General Notes Bearing Requirements Table is based on: – Uniform loads. –More restrictive of simple or continuous span. Ratio of short span to long span should be greater than 0.4 to prevent uplift. – Roof truss framing with 24" soffits. – Exterior wall weights of 80 plf, interior 60 plf. –Deflection criteria of L/360 live load and L/240 total load at floor. ■ ■ Minimum header supports to be two trimmers (3") at each end and 71⁄2" at continuous-span supports. In Sizing Tables on pages 12 and 13: (3) Indicates requirement of three trimmers (41⁄2") at each end and 111⁄4" at continuous-span supports. Tables do not consider attic loads acting concurrently with roof or snow loads. Also see How to Use This Table on page 12 and General Assumptions on page 5. Headers Supporting Floor and Roof continued Roof Load (PSF) House Width 24' Roof Load 20LL + 15DL Floor Load 40LL + 12DL 30' 36' Non-Snow Area 125% 24' Roof Load 20LL + 20DL Floor Load 40LL + 12DL 30' 36' 24' Roof Load 25LL + 15DL Floor Load 40LL + 12DL 30' 36' 24' Snow Area 115% Roof Load 30LL + 15DL Floor Load 40LL + 12DL 30' 36' 24' Roof Load 40LL + 15DL Floor Load 40LL + 12DL 30' 36' T 1.55E TimberStrand® LSL 14' 31/2" x 14" 31/2" x 16" 51/4" x 117⁄ 8" 31/2" x 14" 31/2" x 16" 51/4" x 14" 31/2" x 16"(3) 51/4" x 14" M P T M P M P P T M P T M P M P T M P 31/2" x 14" 31/2" x 16" 51/4" x 117⁄ 8" 31/2" x 16"(3) 51/4" x 14" M T M M T M T M P P P P P 31/2" x 16"(3) 51/4" x 14" 51/4" x 16" 31/2" x 14" 31/2" x 16" 51/4" x 117⁄ 8" 31/2" x 16"(3) 51/4" x 14" M M M M M M M M P P P P P P P P 31/2" x 16"(3) 51/4" x 14" 51/4" x 16" 31/2" x 14" 31/2" x 16" 51/4" x 117⁄ 8" 31/2" x 16"(3) 51/4" x 14" T T T T M M T M M T M P P P P P P M P T M P 31/2" x 16"(3) 31/2" x 18"(3) 51/4" x 14" 31/2" x 16"(3) 51/4" x 14" M M T M T M P P P P P 31/2" x 16"(3) 31/2" x 18"(3) 51/4" x 14" 51/4" x 16"(3) 7" x 14" P M P M P T M P P M 1.9E Microllam® LVL Rough Opening 16'-3" 31/2" x 16" M 51/4" x 14" M 51/4" x 16" T M 31/2" x 18"(3) M 51/4" x 14" 51/4" x 16" T M 31/2" x 18"(3) M 51/4" x 16" M 7" x 14" 31/2" x 16"(3) M 51/4" x 14" M 51/4" x 16" T M 31/2" x 18"(3) M 51/4" x 16" T M 7" x 14" 31/2" x 18"(3) M 51/4" x 16" M 7" x 14" 31/2" x 16"(3) M 51/4" x 14" M 51/4" x 16" T M 31/2" x 18"(3) M 51/4" x 16" T M 7" x 14" 31/2" x 18"(3) 31/2" x 20"(3) M 51/4" x 16" M 31/2" x 16"(3) 31/2" x 18"(3) M 51/4" x 14" M 31/2" x 18"(3) M 51/4" x 16" M 7" x 14" 51/4" x 16"(3) M 7" x 16" P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P 18'-3" 31/2" x 18"(3) 51/4" x 16" 7" x 14" 31/2" x 20"(3) 51/4" x 16" M P M P P M M P 51/4" x 18"(3) 7" x 16" M P P 31/2" x 18"(3) 51/4" x 16" 7" x 14" 31/2" x 20"(3) 51/4" x 18" 7" x 16" 51/4" x 18"(3) 7" x 16" M P M P P M M P P M P P 31/2" x 18"(3) 51/4" x 16" 7" x 14" 31/2" x 20"(3) 51/4" x 18" 7" x 16" 51/4" x 18"(3) 7" x 16" M P M P P M M P P M P P 31/2" x 18"(3) 31/2" x 20"(3) 51/4" x 16" 51/4" x 18"(3) 7" x 16" P M M P M P P 51/4" x 18"(3) 7" x 16" M P P 31/2" x 18"(3) 51/4" x 16" 7" x 14" 51/4" x 16"(3) 7" x 14" M P T M P P M P P 31/2" x 20"(3) 51/4" x 18" 7" x 16" 51/4" x 18"(3) 7" x 16" M M P P M P P 51/4" x 18"(3) 7" x 16" M P P 51/4" x 20"(3) 7" x 18"(3) M P 2.0E Parallam® PSL Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 13 P SIZING TABLES How to Use This Table 1.Determine appropriate Floor Load. Floor framing length 2.Find the Floor Framing Length that meets or exceeds the sum of Spans 1 and 2 for the supported floor joists. When floor joists are continuous span, Span 1 or 2 cannot be less than 40% of the Floor Framing Length. If floor joists are simple span (not continuous over the beam), then the Floor Framing Length may be taken as 80% of Span 1 plus Span 2. Span 1 Span 2 3.Locate Column Spacing. 4. Select beam size and material. Also see General Notes on page 15. Column spacing Floor Beams Floor Load (PSF) Floor Framing Length 8' 31/2" x 91/4" T M P 24' 31/2" x 91/4" T M P 31/2" x 91/4" T M P 31/2" x 91/4" T M P 28' 30' 40LL + 12DL 32' 31/2" x 91/4" T M P 34' 31/2" x 91/4" T M P 31/2" x 91/4" 31/2" x 111/4" 51/4" x 91/4" 31/2" x 91/4" M T M T M T M 31/2" x 91/4" T M P 31/2" x 91/4" T M P 31/2" x 91/4" T M P 31/2" x 91/4" 31/2" x 91/2" 51/4" x 91/4" 31/2" x 91/4" 31/2" x 111/4" 51/4" x 91/4" 31/2" x 91/2" 31/2" x 111/4" 51/4" x 91/4" M P T M P T M P M P T M P T M P P T M P T M P 36' 40' P P P P 24' 28' 30' 40LL + 20DL 32' 34' 36' 40' T 1.55E TimberStrand® LSL 10' 31/2" x 91/2" 31/2" x 111/4" 51/4" x 91/4" 31/2" x 111/4" 51/4" x 91/4" T T T T M M M M M P P P P P 31/2" x 111/4" 51/4" x 91/4" 51/4" x 91/2" 31/2" x 111/4" 51/4" x 91/4" T M M T M T M M P P P P P 31/2" x 111/4" 51/4" x 91/4" T M P M P 31/2" x 117⁄ 8" 51/4" x 91/4" 51/4" x 111/4" 31/2" x 117⁄ 8" 51/4" x 91/2" 51/4" x 111/4" 31/2" x 91/2" 31/2" x 111/4" 51/4" x 91/4" 31/2" x 111/4" 51/4" x 91/4" T M M T M T M M T M M T M T M T M T M P P P P P P P P P P P 31/2" x 111/4" 51/4" x 91/4" 51/4" x 91/2" 31/2" x 117⁄ 8" 51/4" x 91/4" 51/4" x 111/4" 31/2" x 117⁄ 8" 51/4" x 91/4" 51/4" x 111/4" 31/2" x 117⁄ 8" 31/2" x 14" 51/4" x 91/2" 31/2" x 117⁄ 8" 31/2" x 14" 51/4" x 91/2" T M M T M T M M T M T M M T M M T M M P P P P P P P P P P P M 1.9E Microllam® LVL P T M P P Column Spacing 12' 31/2" x 111/4" M 31/2" x 14" T M 51/4" x 91/2" M 31/2" x 117⁄ 8" 31/2" x 14" T M 51/4" x 111/4" T M 31/2" x 117⁄ 8" 31/2" x 14" T M 51/4" x 111/4" T M 31/2" x 14" T M 51/4" x 111/4" M 51/4" x 117⁄ 8" T M 31/2" x 14" T M 51/4" x 111/4" M 51/4" x 117⁄ 8" T M 31/2" x 14" T M 51/4" x 111/4" M 51/4" x 117⁄ 8" T M 31/2" x 14" M 31/2" x 16" T M 51/4" x 117⁄ 8" M 31/2" x 117⁄ 8" M 31/2" x 14" T M 51/4" x 111/4" T M 31/2" x 117⁄ 8" 31/2" x 14" T M 51/4" x 111/4" T M 31/2" x 14" T M 51/4" x 111/4" T M 31/2" x 14" 51/4" x 111/4" 51/4" x 117⁄ 8" 31/2" x 14" 31/2" x 16" 51/4" x 117⁄ 8" 31/2" x 14"(3) 31/2" x 16" 51/4" x 117⁄ 8" 31/2" x 14"(3) 31/2" x 16"(3) 51/4" x 117⁄ 8" P P P P P P P P P P P P P P P P P P P P P P P P P P P P P T M M T M M T M T M M T M T M P P P P P P P P P P T M P M P 14' 31/2" x 14" 51/4" x 111/4" 31/2" x 14" 31/2" x 16" 51/4" x 117⁄ 8" 31/2" x 14" 31/2" x 16" 51/4" x 117⁄ 8" 31/2" x 14" 31/2" x 16" 51/4" x 14" 31/2" x 16" 51/4" x 14" M T M M M T M T T T T M M M M P P P P P P P P P P P 31/2" x 16" 51/4" x 14" T M P T M P 31/2" x 16"(3) 51/4" x 14" M P T M P 31/2" x 14" 31/2" x 16" 51/4" x 117⁄ 8" 31/2" x 14" 31/2" x 16" 51/4" x 117⁄ 8" 31/2" x 14" 31/2" x 16" 51/4" x 14" 31/2" x 16"(3) 51/4" x 14" M P T M P M P P T M P M P P T M P T M P M P T M P 31/2" x 16"(3) 51/4" x 14" M P T M P 31/2" x 16"(3) 31/2" x 18"(3) 51/4" x 14" 31/2" x 16"(3) 31/2" x 18"(3) 51/4" x 14" P M P T M P P M P M P P 2.0E Parallam® PSL Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 14 T M P M P 16' 31/2" x 16" 51/4" x 14" T M P T M P 31/2" x 16" 51/4" x 14" 51/4" x 16" 31/2" x 16" 51/4" x 14" 51/4" x 16" 31/2" x 16"(3) 31/2" x 18"(3) 51/4" x 14" 31/2" x 16"(3) 31/2" x 18"(3) 51/4" x 14" 31/2" x 18"(3) 51/4" x 14" 51/4" x 16" 31/2" x 18"(3) 51/4" x 16" 7" x 14" 31/2" x 16" 51/4" x 14" M M T M M M T M 31/2" x 16"(3) 31/2" x 18"(3) 51/4" x 14" 31/2" x 16"(3) 31/2" x 18"(3) 51/4" x 14" 31/2" x 18"(3) 51/4" x 14" 51/4" x 16" 31/2" x 18"(3) 51/4" x 16" 7" x 14" 31/2" x 18"(3) 31/2" x 20"(3) 51/4" x 16" 31/2" x 18"(3) 31/2" x 20"(3) 51/4" x 16" P M P M P P M P M P M P P T M P M P T M P P P M T M P P M M P M M M M M T M M T M M T M P P P P P P P P P P P P P P P P P P P P SIZING TABLES General Notes Bearing Requirements Table is based on: – Uniform loads. –More restrictive of simple or continuous beam span. Ratio of short span to long span should be greater than 0.4 to prevent uplift. –Deflection criteria of L/360 live load and L/240 total load. ■ Minimum beam supports to be two trimmers (3") at each end and 71⁄2" at continuous-span supports. In Sizing Tables on pages 14 and 15: (3) Indicates requirement of three trimmers (41⁄2") at each end and 111⁄4" at continuous-span supports. Also see How to Use This Table on page 14 and General Assumptions on page 5. Floor Beams continued Floor Load (PSF) Floor Framing Length 34' 36' 51/4" x 16" 51/4" x 18" P M P 40' 51/4" x 18"(3) 7" x 16" M P P 24' 28' 30' 40LL + 12DL 32' 34' 36' 40' 24' 28' 30' 40LL + 20DL Column Spacing 18' 31/2" x 18" 51/4" x 14" 51/4" x 16" 31/2" x 18" 51/4" x 16" 7" x 14" 31/2" x 18"(3) 51/4" x 16" 7" x 14" 31/2" x 18"(3) 31/2" x 20"(3) 51/4" x 16" 31/2" x 18"(3) 31/2" x 20"(3) 51/4" x 16" 31/2" x 18"(3) 31/2" x 20"(3) 51/4" x 16" 31/2" x 20"(3) 51/4" x 16" 51/4" x 18" 31/2" x 18"(3) 51/4" x 16" 7" x 14" 31/2" x 18"(3) 31/2" x 20"(3) 51/4" x 16" 31/2" x 18"(3) 31/2" x 20"(3) 51/4" x 16" 31/2" x 20"(3) 51/4" x 16" 7" x 14" 51/4" x 16" 51/4" x 18" 32' T 1.55E TimberStrand® LSL M P P T M P M P T M P P M P M P P P M M P P M M P P M M P M P M P M P T M P P P M M P P M M P M M P P P M P 20' 31/2" x 18" 31/2" x 20" 51/4" x 16" 31/2" x 20"(3) 51/4" x 16" 51/4" x 18" 31/2" x 20"(3) 51/4" x 18" 7" x 16" 31/2" x 20"(3) 51/4" x 18" 7" x 16" 51/4" x 18" 7" x 16" M M P M P M P M M P P M M P P M P P 51/4" x 18" 7" x 16" P 22' 31/2" x 20"(3) 51/4" x 18" 7" x 16" 51/4" x 18" 7" x 16" M M P P M P P 51/4" x 18" 7" x 16" 51/4" x 18" 51/4" x 20" M 24' 51/4" x 20" 7" x 18" M P 51/4" x 20" 7" x 18" M M P P 51/4" x 20" 7" x 18" M P 51/4" x 20" 7" x 18" M 51/4" x 20" 7" x 18" M P P P 51/4" x 20" 7" x 18" M M P P 51/4" x 20" 7" x 18" M 51/4" x 18" 7" x 16" M P P 51/4" x 20"(3) 7" x 18" M 31/2" x 20"(3) 51/4" x 16" M M P 51/4" x 18" 7" x 16" M P P 51/4" x 20" 7" x 18" M 51/4" x 18" 7" x 16" M P P 51/4" x 18" 51/4" x 20" P 51/4" x 20" 7" x 18" M M 51/4" x 18" 7" x 16" M P P 51/4" x 20" 7" x 18" M 51/4" x 18" 7" x 16" M P P 51/4" x 20"(3) 7" x 18" M 51/4" x 18" 7" x 16" M P P 51/4" x 20"(3) 7" x 18" M 51/4" x 18"(3) 51/4" x 20"(3) 7" x 16" 51/4" x 20"(3) 7" x 18" M 1.9E Microllam® LVL P P 7" x 18" P 7" x 18" P P P 7" x 18" P 7" x 18" P P P P 2.0E Parallam® PSL Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 15 P P M M P P P P Floor Load Tables How to Use This Table 1.Calculate total and live load (neglect beam weight) on the beam or header in pounds per linear foot (plf). 2.Select appropriate Span (center-to-center of bearing). 3.Scan horizontally to find the proper width, and a depth with a capacity that exceeds actual total and live loads. 4.Review bearing length requirements to ensure adequacy. Also see General Notes on page 17. TimberStrand® LSL: Floor—100% (PLF) Span 1.3E Grade Condition Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load 4' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 5' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 6' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 7' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 8' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 9'-6" Live Load L/360 Min. End/Int. Bearing (in.) Total Load 10' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 12' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 14' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 16'-6" Live Load L/360 Min. End/Int. Bearing (in.) Total Load 18'-6" Live Load L/360 Min. End/Int. Bearing (in.) Total Load 20' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 24' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 28' Live Load L/360 Min. End/Int. Bearing (in.) 3' 4 3⁄ 8" 1,538 1,420 1.5/3.5 863 652 1.5/3.5 517 348 1.5/3.5 305 206 1.5/3.5 172 132 1.5/3.5 100 89 1.5/3.5 51 ⁄ 2 " 2,382 * 1.5/3.8 1,337 1,215 1.5/3.5 854 662 1.5/3.5 590 397 1.5/3.5 337 256 1.5/3.5 198 174 1.5/3.5 98 * 1.5/3.5 79 * 1.5/3.5 31⁄2" Width 71⁄4" 85 ⁄ 8" 4,037 5,624 * * 2.5/6.4 3.6/8.9 2,268 3,160 * * 1.9/4.8 2.7/6.7 1,449 2,019 1,399 * 1.5/3.8 2.1/5.3 1,004 1,399 857 1,367 1.5/3.5 1.8/4.4 735 1,026 560 904 1.5/3.5 1.5/3.8 443 783 384 626 1.5/3.5 1.5/3.5 225 553 386 * 1.5/3.5 1.5/3.5 183 492 334 * 1.5/3.5 1.5/3.5 86 288 198 * 1.5/3.5 1.5/3.5 181 126 1.5/3.5 108 78 1.5/3.5 75 56 1.5/3.5 57 44 1.5/3.5 1.55E Grade 91⁄4" 111⁄4" 6,428 7,128 * * 4.1/10.1 4.5/11.3 3,611 5,249 * * 3.0/7.6 4.4/11.1 2,308 3,355 * * 2.4/6.1 3.5/8.8 1,599 2,326 * * 2.0/5.1 2.9/7.4 1,172 1,706 1,092 * 1.7/4.3 2.5/6.3 895 1,303 759 1,290 1.5/3.8 2.2/5.5 632 921 470 811 1.5/3.5 1.9/4.7 569 830 407 704 1.5/3.5 1.8/4.4 353 573 241 423 1.5/3.5 1.5/3.7 222 397 154 272 1.5/3.5 1.5/3.5 134 242 95 169 1.5/3.5 1.5/3.5 93 170 68 121 1.5/3.5 1.5/3.5 72 133 54 96 1.5/3.5 1.5/3.5 73 56 1.5/3.5 51⁄2" Plank Orientation 31 ⁄ 2 " 1,210 * 1.5/3.5 814 547 1.5/3.5 426 288 1.5/3.5 248 169 1.5/3.5 138 107 1.5/3.5 79 72 1.5/3.5 91⁄4" 3,024 * 3.3/8.2 1,929 * 2.8/7.0 1,416 * 2.6/6.4 1,095 978 2.4/5.9 803 651 2.1/5.1 613 453 1.8/4.5 416 280 1.5/3.6 359 242 1.5/3.5 211 144 1.5/3.5 133 92 1.5/3.5 80 57 1.5/3.5 56 40 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 16 13⁄4" Width 91⁄ 2 " 111⁄4" 117⁄ 8" 14" 3,166 4,192 4,192 4,192 * * * * 3.4/8.5 4.5/11.3 4.5/11.3 4.5/11.3 2,006 2,597 2,836 3,142 * * * * 2.9/7.2 3.8/9.3 4.1/10.2 4.5/11.3 1,467 1,853 2,004 2,512 * * * * 2.6/6.6 3.4/8.4 3.6/9.0 4.5/11.3 1,152 1,440 1,549 1,952 1,048 * * * 2.5/6.2 3.1/7.8 3.3/8.3 4.2/10.5 845 1,168 1,262 1,570 699 1,089 1,250 * 2.1/5.3 3.0/7.4 3.2/7.9 3.9/9.9 646 893 990 1,313 487 769 886 * 1.9/4.7 2.6/6.5 2.8/7.1 3.8/9.4 448 631 700 960 302 483 560 870 1.5/3.9 2.2/5.5 2.4/6.0 3.3/8.2 387 569 631 865 261 420 487 760 1.5/3.5 2.1/5.2 2.3/5.7 3.1/7.8 228 372 434 599 155 252 293 464 1.5/3.5 1.7/4.1 1.9/4.7 2.6/6.5 144 237 278 438 99 162 189 302 1.5/3.5 1.5/3.5 1.5/3.6 2.2/5.6 87 145 170 277 61 101 118 189 1.5/3.5 1.5/3.5 1.5/3.5 1.7/4.2 60 102 120 197 44 72 84 136 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 80 94 156 57 67 109 1.5/3.5 1.5/3.5 1.5/3.5 52 88 39 64 1.5/3.5 1.5/3.5 53 40 1.5/3.5 Floor Load Tables General Notes ■ ■ Table is based on: –Uniform loads (beam weight considered). –More restrictive of simple or continuous span. –Deflection criteria of L/240 total load (TL) and L/360 live load (LL). For live load deflection limits of L/240 or L/480, multiply Live Load L/360 values by 1.5 or 0.75, respectively. The resulting live load must not exceed the total load shown. Also see How to Use this Table on page 16 and General Assumptions on page 5. TimberStrand® LSL: Floor—100% (PLF) continued Span 1.55E Grade Condition Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load 4' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 5' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 6' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 7' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 8' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 9'-6" Live Load L/360 Min. End/Int. Bearing (in.) Total Load 10' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 12' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 14' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 16'-6" Live Load L/360 Min. End/Int. Bearing (in.) Total Load 18'-6" Live Load L/360 Min. End/Int. Bearing (in.) Total Load 20' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 24' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 28' Live Load L/360 Min. End/Int. Bearing (in.) 3' 91⁄4" 6,049 * 3.3/8.2 3,859 * 2.8/7.0 2,832 * 2.6/6.4 2,190 1,957 2.4/5.9 1,606 1,302 2.1/5.1 1,227 906 1.8/4.5 832 561 1.5/3.6 718 485 1.5/3.5 422 288 1.5/3.5 266 184 1.5/3.5 161 114 1.5/3.5 112 81 1.5/3.5 87 64 1.5/3.5 31⁄2" Width 91⁄ 2 " 111⁄4" 117⁄ 8" 14" 16" 91⁄4" 6,332 8,382 8,382 8,382 8,382 9,074 * * * * * * 3.4/8.5 4.5/11.3 4.5/11.3 4.5/11.3 4.5/11.3 3.3/8.2 4,012 5,195 5,673 6,282 6,282 5,788 * * * * * * 2.9/7.2 3.8/9.3 4.1/10.2 4.5/11.3 4.5/11.3 2.8/7.0 2,934 3,707 4,009 5,022 5,022 4,248 * * * * * * 2.6/6.6 3.4/8.4 3.6/9.0 4.5/11.3 4.5/11.3 2.6/6.4 2,305 2,881 3,098 3,904 4,182 3,286 2,097 2,936 * * * * 2.5/6.2 3.1/7.8 3.3/8.3 4.2/10.5 4.5/11.3 2.4/5.9 1,691 2,336 2,524 3,141 3,582 2,410 1,399 2,179 2,501 1,954 * * 2.1/5.3 3.0/7.4 3.2/7.9 3.9/9.9 4.5/11.3 2.1/5.1 1,292 1,786 1,981 2,626 3,132 1,841 974 1,538 1,773 1,359 * * 1.9/4.7 2.6/6.5 2.8/7.1 3.8/9.4 4.5/11.3 1.8/4.5 897 1,263 1,401 1,920 2,480 1,248 605 967 1,121 1,740 2,456 842 1.5/3.9 2.2/5.5 2.4/6.0 3.3/8.2 4.3/10.6 1.5/3.6 775 1,138 1,263 1,731 2,236 1,077 523 840 974 1,520 2,154 728 1.5/3.5 2.1/5.2 2.3/5.7 3.1/7.8 4.1/10.1 1.5/3.5 456 744 868 1,198 1,547 633 311 504 587 928 1,334 432 1.5/3.5 1.7/4.1 1.9/4.7 2.6/6.5 3.4/8.4 1.5/3.5 288 475 556 876 1,132 400 199 325 379 605 877 276 1.5/3.5 1.5/3.5 1.5/3.6 2.2/5.6 2.9/7.2 1.5/3.5 174 291 341 554 810 241 123 202 236 379 555 171 1.5/3.5 1.5/3.5 1.5/3.5 1.7/4.2 2.5/6.1 1.5/3.5 121 205 241 395 584 168 88 144 169 273 401 122 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 2.0/5.0 1.5/3.5 94 160 189 312 463 130 70 115 135 218 320 97 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 1.8/4.3 1.5/3.5 50 88 105 177 266 69 40 67 79 128 189 56 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 51 62 107 163 42 50 81 120 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 51⁄4" Width (2- or 3-ply) 91⁄ 2 " 111⁄4" 117⁄ 8" 14" 16" 9,499 12,573 12,573 12,573 12,573 * * * * * 3.4/8.5 4.5/11.3 4.5/11.3 4.5/11.3 4.5/11.3 6,018 7,793 8,510 9,423 9,423 * * * * * 2.9/7.2 3.8/9.3 4.1/10.2 4.5/11.3 4.5/11.3 4,401 5,561 6,014 7,533 7,533 * * * * * 2.6/6.6 3.4/8.4 3.6/9.0 4.5/11.3 4.5/11.3 3,458 4,321 4,648 5,857 6,273 3,146 * * * * 2.5/6.2 3.1/7.8 3.3/8.3 4.2/10.5 4.5/11.3 2,536 3,505 3,786 4,711 5,373 2,098 3,269 3,752 * * 2.1/5.3 3.0/7.4 3.2/7.9 3.9/9.9 4.5/11.3 1,938 2,679 2,971 3,939 4,698 1,462 2,307 2,660 * * 1.9/4.7 2.6/6.5 2.8/7.1 3.8/9.4 4.5/11.3 1,346 1,894 2,101 2,880 3,720 907 1,451 1,681 2,610 3,684 1.5/3.9 2.2/5.5 2.4/6.0 3.3/8.2 4.3/10.6 1,162 1,708 1,894 2,597 3,355 785 1,260 1,462 2,280 3,232 1.5/3.5 2.1/5.2 2.3/5.7 3.1/7.8 4.1/10.1 685 1,116 1,302 1,797 2,321 467 756 881 1,393 2,001 1.5/3.5 1.7/4.1 1.9/4.7 2.6/6.5 3.4/8.4 433 713 834 1,314 1,698 299 487 569 907 1,316 1.5/3.5 1.5/3.5 1.5/3.6 2.2/5.6 2.9/7.2 262 436 512 831 1,215 185 303 354 569 832 1.5/3.5 1.5/3.5 1.5/3.5 1.7/4.2 2.5/6.1 182 307 362 592 876 132 217 254 410 601 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 2.0/5.0 142 240 284 468 695 105 172 202 327 481 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 1.8/4.3 76 133 158 265 400 61 101 118 192 284 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 77 93 160 245 64 75 122 181 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 17 Floor Load Tables How to Use This Table 1.Calculate total and live load (neglect beam weight) on the beam or header in pounds per linear foot (plf). 2.Select appropriate Span (center-to-center of bearing). 3.Scan horizontally to find the proper width, and a depth with a capacity that exceeds actual total and live loads. 4.Review bearing length requirements to ensure adequacy. Also see General Notes on page 19. 1.9E Microllam® LVL: Floor—100% (PLF) Span Condition Total Load 6' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 8' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 9'-6" Live Load L/360 Min. End/Int. Bearing (in.) Total Load 10' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 12' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 14' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 16'-6" Live Load L/360 Min. End/Int. Bearing (in.) Total Load 18'-6" Live Load L/360 Min. End/Int. Bearing (in.) Total Load 20' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 22' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 24' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 26' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 28' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 30' Live Load L/360 Min. End/Int. Bearing (in.) 51 ⁄ 2 " 432 290 1.5/3.5 146 126 1.5/3.5 73 * 1.5/3.5 59 * 1.5/3.5 71⁄4" 762 626 1.8/4.4 326 280 1.5/3.5 166 * 1.5/3.5 135 * 1.5/3.5 64 * 1.5/3.5 91⁄4" 1,027 * 2.4/5.9 695 555 2.1/5.3 491 344 1.8/4.5 441 297 1.7/4.3 260 176 1.5/3.5 164 113 1.5/3.5 100 69 1.5/3.5 70 49 1.5/3.5 54 39 1.5/3.5 13 ⁄4" Width 91 ⁄ 2 " 1,062 * 2.4/6.1 731 597 2.2/5.6 517 370 1.9/4.7 466 321 1.8/4.5 281 190 1.5/3.5 178 122 1.5/3.5 108 75 1.5/3.5 76 54 1.5/3.5 59 42 1.5/3.5 111⁄4" 1,324 * 3.0/7.6 915 * 2.8/7.0 709 592 2.6/6.5 639 514 2.5/6.1 442 309 2.0/5.1 293 199 1.6/4.0 180 123 1.5/3.5 127 88 1.5/3.5 100 70 1.5/3.5 74 53 1.5/3.5 56 41 1.5/3.5 117⁄8" 14" 1,424 1,794 * * 3.3/8.2 4.1/10.3 978 1,207 * * 3.0/7.5 3.7/9.3 784 968 687 * 2.9/7.2 3.5/8.8 707 908 597 * 2.7/6.8 3.5/8.7 489 666 360 569 2.3/5.7 3.1/7.7 342 487 232 370 1.9/4.7 2.6/6.6 211 342 145 232 1.5/3.5 2.2/5.5 149 244 103 167 1.5/3.5 1.8/4.4 118 193 82 133 1.5/3.5 1.5/3.8 87 144 62 101 1.5/3.5 1.5/3.5 66 110 48 78 1.5/3.5 1.5/3.5 51 86 38 62 1.5/3.5 1.5/3.5 67 49 1.5/3.5 54 40 1.5/3.5 51 ⁄ 2 " 864 580 1.5/3.5 292 253 1.5/3.5 146 * 1.5/3.5 118 * 1.5/3.5 54 * 1.5/3.5 71⁄4" 1,525 1,253 1.8/4.4 652 561 1.5/3.5 332 * 1.5/3.5 270 * 1.5/3.5 128 * 1.5/3.5 66 * 1.5/3.5 31 ⁄ 2" Width (2-ply) 91⁄4" 91 ⁄ 2 " 2,055 2,125 * * 2.4/5.9 2.4/6.1 1,391 1,462 1,110 1,195 2.1/5.3 2.2/5.6 983 1,034 688 741 1.8/4.5 1.9/4.7 883 932 595 642 1.7/4.3 1.8/4.5 521 563 353 381 1.5/3.5 1.5/3.5 329 357 226 244 1.5/3.5 1.5/3.5 200 217 139 151 1.5/3.5 1.5/3.5 140 152 99 108 1.5/3.5 1.5/3.5 109 119 85 79 1.5/3.5 1.5/3.5 80 87 59 64 1.5/3.5 1.5/3.5 60 65 46 50 1.5/3.5 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 18 111⁄4" 2,648 * 3.0/7.6 1,830 * 2.8/7.0 1,418 1,185 2.6/6.5 1,279 1,029 2.5/6.1 885 618 2.0/5.1 586 398 1.6/4.0 360 247 1.5/3.5 254 177 1.5/3.5 200 141 1.5/3.5 148 106 1.5/3.5 112 82 1.5/3.5 86 65 1.5/3.5 67 52 1.5/3.5 52 42 1.5/3.5 117⁄8" 2,848 * 3.3/8.2 1,956 * 3.0/7.5 1,570 1,374 2.9/7.2 1,415 1,195 2.7/6.8 979 720 2.3/5.7 685 465 1.9/4.7 422 290 1.5/3.5 299 207 1.5/3.5 236 165 1.5/3.5 175 125 1.5/3.5 133 96 1.5/3.5 102 76 1.5/3.5 80 61 1.5/3.5 62 50 1.5/3.5 Floor Load Tables General Notes ■ ■ Table is based on: –Uniform loads (beam weight considered). – More restrictive of simple or continuous span. – Deflection criteria of L/240 total load (TL) and L/360 live load (LL). For live load deflection limits of L/240 or L/480, multiply Live Load L/360 values by 1.5 or 0.75, respectively. The resulting live load must not exceed the total load shown. Also see How to Use This Table on page 18 and General Assumptions on page 5. 1.9E Microllam® LVL: Floor—100% (PLF) continued Span Condition Total Load Live Load L/360 Min. End/Int. Bearing (in.) Total Load 8' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 9'-6" Live Load L/360 Min. End/Int. Bearing (in.) Total Load 10' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 12' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 14' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 16'-6" Live Load L/360 Min. End/Int. Bearing (in.) Total Load 18'-6" Live Load L/360 Min. End/Int. Bearing (in.) Total Load 20' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 22' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 24' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 26' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 28' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 30' Live Load L/360 Min. End/Int. Bearing (in.) 6' 14" 3,589 * 4.1/10.3 2,414 * 3.7/9.3 1,937 * 3.5/8.8 1,817 * 3.5/8.7 1,333 1,138 3.1/7.7 975 741 2.6/6.6 684 465 2.2/5.5 488 335 1.8/4.4 387 267 1.5/3.8 289 202 1.5/3.5 221 157 1.5/3.5 172 124 1.5/3.5 135 99 1.5/3.5 108 81 1.5/3.5 31 ⁄ 2" Width (2-ply) 16" 18" 3,917 3,917 * * 4.5/11.3 4.5/11.3 2,885 2,932 * * 4.4/11.1 4.5/11.3 2,294 2,466 * * 4.2/10.5 4.5/11.3 2,147 2,342 * * 4.1/10.3 4.5/11.3 1,709 1,948 1,635 * 3.9/9.9 4.5/11.3 1,253 1,563 1,075 1,483 3.4/8.5 4.2/10.5 897 1,120 680 945 2.9/7.2 3.6/8.9 710 887 491 686 2.6/6.4 3.2/8.0 573 756 393 550 2.2/5.6 3.0/7.4 432 611 298 419 1.9/4.7 2.6/6.6 332 471 232 326 1.6/4.0 2.2/5.6 259 370 183 259 1.5/3.5 1.9/4.8 205 294 148 208 1.5/3.5 1.7/4.2 164 120 1.5/3.5 237 170 1.5/3.7 20" 3,917 * 4.5/11.3 2,932 * 4.5/11.3 2,466 * 4.5/11.3 2,342 * 4.5/11.3 1,948 * 4.5/11.3 1,667 * 4.5/11.3 1,365 1,263 4.4/10.9 1,082 922 3.9/9.7 922 741 3.6/9.0 759 566 3.3/8.2 634 442 3.0/7.5 506 351 2.6/6.5 405 283 2.3/5.7 51 ⁄ 2 " 1,297 870 1.5/3.5 438 380 1.5/3.5 219 * 1.5/3.5 177 * 1.5/3.5 82 * 1.5/3.5 71⁄4" 2,287 1,879 1.8/4.4 978 842 1.5/3.5 498 * 1.5/3.5 406 * 1.5/3.5 193 * 1.5/3.5 100 * 1.5/3.5 327 232 2.0/5.0 91⁄4" 3,082 * 2.4/5.9 2,086 1,666 2.1/5.3 1,475 1,032 1.8/4.5 1,325 893 1.7/4.3 781 530 1.5/3.5 494 339 1.5/3.5 300 209 1.5/3.5 210 149 1.5/3.5 164 119 1.5/3.5 120 89 1.5/3.5 89 69 1.5/3.5 67 54 1.5/3.5 51 43 1.5/3.5 91 ⁄ 2 " 3,188 * 2.4/6.1 2,193 1,792 2.2/5.6 1,551 1,112 1.9/4.7 1,398 963 1.8/4.5 844 572 1.5/3.5 535 366 1.5/3.5 326 227 1.5/3.5 228 162 1.5/3.5 178 128 1.5/3.5 131 97 1.5/3.5 98 75 1.5/3.5 74 59 1.5/3.5 56 47 1.5/3.5 51⁄4" Width (3-ply) 111⁄4" 117⁄8" 14" 16" 18" 20" 3,972 4,272 5,384 5,875 5,875 5,875 * * * * * * 3.0/7.6 3.3/8.2 4.1/10.3 4.5/11.3 4.5/11.3 4.5/11.3 2,745 2,935 3,621 4,328 4,399 4,399 * * * * * * 2.8/7.0 3.0/7.5 3.7/9.3 4.4/11.1 4.5/11.3 4.5/11.3 2,128 2,354 2,905 3,441 3,699 3,699 1,778 2,061 * * * * 2.6/6.5 2.9/7.2 3.5/8.8 4.2/10.5 4.5/11.3 4.5/11.3 1,919 2,123 2,725 3,221 3,513 3,513 1,544 1,792 * * * * 2.5/6.1 2.7/6.8 3.5/8.7 4.1/10.3 4.5/11.2 4.5/11.2 1,327 1,469 2,000 2,563 2,922 2,922 927 1,080 1,707 2,453 * * 2.0/5.1 2.3/5.7 3.1/7.7 3.9/9.9 4.5/11.2 4.5/11.2 879 1,028 1,463 1,880 2,345 2,500 597 697 1,112 1,613 2,225 * 1.6/4.0 1.9/4.7 2.6/6.6 3.4/8.5 4.2/10.5 4.5/11.2 540 634 1,026 1,346 1,680 2,048 371 435 698 1,020 1,418 1,895 1.5/3.5 1.5/3.5 2.2/5.5 2.9/7.2 3.6/8.9 4.4/10.9 382 449 733 1,066 1,331 1,623 266 311 502 737 1,030 1,383 1.5/3.5 1.5/3.5 1.8/4.4 2.6/6.4 3.2/8.0 3.9/9.7 300 354 580 860 1,134 1,384 212 248 401 590 826 1,112 1.5/3.5 1.5/3.5 1.5/3.8 2.2/5.6 3.0/7.4 3.6/9.0 223 263 434 648 916 1,138 160 187 304 448 629 850 1.5/3.5 1.5/3.5 1.5/3.5 1.9/4.7 2.6/6.6 3.3/8.2 168 199 332 498 707 951 123 145 235 348 490 663 1.5/3.5 1.5/3.5 1.5/3.5 1.6/4.0 2.2/5.6 3.0/7.5 129 153 258 389 555 760 97 114 186 275 388 527 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 1.9/4.8 2.6/6.5 100 120 203 308 442 607 78 92 149 222 313 425 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 1.7/4.2 2.3/5.7 78 63 1.5/3.5 94 75 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 19 162 122 1.5/3.5 247 181 1.5/3.5 356 256 1.5/3.7 491 348 2.0/5.0 Floor Load Tables How to Use This Table 1.Calculate total and live load (neglect beam weight) on the beam or header in pounds per linear foot (plf). 2.Select appropriate Span (center-to-center of bearing). 3.Scan horizontally to find the proper width, and a depth with a capacity that exceeds actual total and live loads. 4.Review bearing length requirements to ensure adequacy. Also see General Notes on page 21. 2.0E Parallam® PSL: Floor—100% (PLF) Span Condition Total Load 8' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 9'-6" Live Load L/360 Min. End/Int. Bearing (in.) Total Load 10' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 12' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 14' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 16'-6" Live Load L/360 Min. End/Int. Bearing (in.) Total Load 18'-6" Live Load L/360 Min. End/Int. Bearing (in.) Total Load 20' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 22' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 24' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 26' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 28' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 30' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 32' Live Load L/360 Min. End/Int. Bearing (in.) 91 ⁄4" 1,469 1,169 2.3/5.6 1,076 724 2.0/4.9 930 626 1.8/4.5 548 372 1.5/3.5 347 238 1.5/3.5 210 147 1.5/3.5 147 105 1.5/3.5 115 83 1.5/3.5 84 63 1.5/3.5 62 48 1.5/3.5 91 ⁄ 2 " 1,517 1,257 2.3/5.8 1,147 780 2.1/5.2 1,003 675 1.9/4.8 592 401 1.5/3.5 375 257 1.5/3.5 228 159 1.5/3.5 160 113 1.5/3.5 125 90 1.5/3.5 91 68 1.5/3.5 68 52 1.5/3.5 51 41 1.5/3.5 111 ⁄4" 1,861 * 2.9/7.1 1,510 1,248 2.8/6.9 1,420 1,084 2.7/6.8 964 651 2.2/5.6 616 419 1.7/4.2 379 260 1.5/3.5 268 186 1.5/3.5 210 148 1.5/3.5 156 112 1.5/3.5 118 86 1.5/3.5 90 68 1.5/3.5 70 55 1.5/3.5 55 44 1.5/3.5 31 ⁄ 2" Width 117⁄ 8" 1,990 * 3.1/7.6 1,611 1,446 2.9/7.3 1,514 1,257 2.9/7.3 1,092 758 2.5/6.3 721 489 2.0/4.9 444 305 1.5/3.6 315 218 1.5/3.5 248 174 1.5/3.5 184 131 1.5/3.5 140 102 1.5/3.5 107 80 1.5/3.5 84 64 1.5/3.5 66 52 1.5/3.5 52 43 1.5/3.5 14" 2,456 * 3.8/9.4 1,970 * 3.6/9.0 1,848 * 3.5/8.9 1,480 1,198 3.4/8.5 1,093 780 3.0/7.4 720 490 2.3/5.8 514 352 1.9/4.7 407 281 1.6/4.0 304 213 1.5/3.5 232 165 1.5/3.5 180 130 1.5/3.5 142 105 1.5/3.5 113 85 1.5/3.5 91 70 1.5/3.5 16" 2,933 * 4.5/11.3 2,333 * 4.3/10.6 2,184 * 4.2/10.5 1,738 1,721 4.0/10.0 1,409 1,132 3.8/9.5 1,009 716 3.2/8.1 759 517 2.7/6.8 603 414 2.4/5.9 454 314 2.0/4.9 349 244 1.7/4.2 272 193 1.5/3.6 216 155 1.5/3.5 173 127 1.5/3.5 140 105 1.5/3.5 18" 2,933 * 4.5/11.3 2,467 * 4.5/11.3 2,342 * 4.5/11.3 1,949 * 4.5/11.3 1,660 1,561 4.5/11.3 1,263 995 4.0/10.1 1,000 722 3.6/9.0 850 579 3.3/8.3 642 441 2.8/6.9 496 343 2.4/5.9 389 272 2.0/5.1 310 219 1.8/4.4 249 179 1.5/3.9 203 148 1.5/3.5 91 ⁄4" 2,204 1,753 2.3/5.6 1,614 1,086 2.0/4.9 1,395 940 1.8/4.5 822 558 1.5/3.5 520 357 1.5/3.5 316 220 1.5/3.5 221 157 1.5/3.5 172 125 1.5/3.5 126 94 1.5/3.5 94 73 1.5/3.5 71 57 1.5/3.5 54 46 1.5/3.5 91 ⁄ 2 " 2,275 1,886 2.3/5.8 1,720 1,171 2.1/5.2 1,505 1,013 1.9/4.8 888 602 1.5/3.5 563 386 1.5/3.5 342 238 1.5/3.5 240 170 1.5/3.5 187 135 1.5/3.5 137 102 1.5/3.5 103 79 1.5/3.5 77 62 1.5/3.5 59 50 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 20 111 ⁄4" 2,792 * 2.9/7.1 2,265 1,872 2.8/6.9 2,130 1,626 2.7/6.8 1,446 976 2.2/5.6 925 629 1.7/4.2 568 391 1.5/3.5 402 280 1.5/3.5 316 223 1.5/3.5 234 168 1.5/3.5 177 130 1.5/3.5 135 102 1.5/3.5 105 82 1.5/3.5 82 67 1.5/3.5 64 55 1.5/3.5 51 ⁄4" Width 117⁄ 8" 2,985 * 3.1/7.6 2,416 2,170 2.9/7.3 2,271 1,886 2.9/7.3 1,639 1,137 2.5/6.3 1,082 734 2.0/4.9 667 457 1.5/3.6 473 328 1.5/3.5 372 261 1.5/3.5 277 197 1.5/3.5 210 153 1.5/3.5 161 120 1.5/3.5 126 97 1.5/3.5 99 79 1.5/3.5 78 65 1.5/3.5 14" 3,683 * 3.8/9.4 2,955 * 3.6/9.0 2,772 * 3.5/8.9 2,220 1,797 3.4/8.5 1,639 1,171 3.0/7.4 1,080 735 2.3/5.8 771 529 1.9/4.7 610 422 1.6/4.0 457 320 1.5/3.5 349 248 1.5/3.5 271 196 1.5/3.5 213 157 1.5/3.5 170 128 1.5/3.5 136 106 1.5/3.5 16" 4,400 * 4.5/11.3 3,500 * 4.3/10.6 3,276 * 4.2/10.5 2,607 2,582 4.0/10.0 2,113 1,698 3.8/9.5 1,514 1,074 3.2/8.1 1,138 776 2.7/6.8 905 621 2.4/5.9 681 472 2.0/4.9 523 366 1.7/4.2 409 290 1.5/3.6 324 233 1.5/3.5 260 190 1.5/3.5 210 157 1.5/3.5 18" 4,400 * 4.5/11.3 3,700 * 4.5/11.3 3,514 * 4.5/11.3 2,923 * 4.5/11.3 2,490 2,342 4.5/11.3 1,895 1,493 4.0/10.1 1,501 1,084 3.6/9.0 1,275 869 3.3/8.3 964 662 2.8/6.9 744 515 2.4/5.9 584 409 2.0/5.1 465 329 1.8/4.4 374 269 1.5/3.9 305 223 1.5/3.5 Floor Load Tables General Notes ■ ■ Table is based on: –Uniform loads (beam weight considered). – More restrictive of simple or continuous span. – Deflection criteria of L/240 total load (TL) and L/360 live load (LL). For live load deflection limits of L/240 or L/480, multiply Live Load L/360 values by 1.5 or 0.75, respectively. The resulting live load must not exceed the total load shown. Also see How to Use This Table on page 20 and General Assumptions on page 5. 2.0E Parallam® PSL: Floor—100% (PLF) continued Span Condition Total Load 8' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 9'-6" Live Load L/360 Min. End/Int. Bearing (in.) Total Load 10' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 12' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 14' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 16'-6" Live Load L/360 Min. End/Int. Bearing (in.) Total Load 18'-6" Live Load L/360 Min. End/Int. Bearing (in.) Total Load 20' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 22' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 24' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 26' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 28' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 30' Live Load L/360 Min. End/Int. Bearing (in.) Total Load 32' Live Load L/360 Min. End/Int. Bearing (in.) 91 ⁄4" 2,939 2,338 2.3/5.6 2,153 1,448 2.0/4.9 1,860 1,253 1.8/4.5 1,096 744 1.5/3.5 694 476 1.5/3.5 421 294 1.5/3.5 295 210 1.5/3.5 230 167 1.5/3.5 168 126 1.5/3.5 125 97 1.5/3.5 94 76 1.5/3.5 72 61 1.5/3.5 54 50 1.5/3.5 91 ⁄ 2 " 3,034 2,515 2.3/5.8 2,294 1,561 2.1/5.2 2,006 1,351 1.9/4.8 1,184 803 1.5/3.5 751 514 1.5/3.5 457 318 1.5/3.5 320 227 1.5/3.5 250 180 1.5/3.5 183 136 1.5/3.5 137 105 1.5/3.5 103 83 1.5/3.5 79 66 1.5/3.5 60 54 1.5/3.5 111 ⁄4" 3,723 * 2.9/7.1 3,020 2,496 2.8/6.9 2,841 2,168 2.7/6.8 1,928 1,302 2.2/5.6 1,233 839 1.7/4.2 758 521 1.5/3.5 536 373 1.5/3.5 421 297 1.5/3.5 312 224 1.5/3.5 236 173 1.5/3.5 181 137 1.5/3.5 140 110 1.5/3.5 110 89 1.5/3.5 86 74 1.5/3.5 7" Width 117⁄ 8" 3,981 * 3.1/7.6 3,222 2,893 2.9/7.3 3,029 2,515 2.9/7.3 2,185 1,516 2.5/6.3 1,443 979 2.0/4.9 889 610 1.5/3.6 630 437 1.5/3.5 497 348 1.5/3.5 369 263 1.5/3.5 280 204 1.5/3.5 215 161 1.5/3.5 168 129 1.5/3.5 132 105 1.5/3.5 104 87 1.5/3.5 14" 4,912 * 3.8/9.4 3,940 * 3.6/9.0 3,696 * 3.5/8.9 2,960 2,396 3.4/8.5 2,186 1,561 3.0/7.4 1,440 980 2.3/5.8 1,028 705 1.9/4.7 814 563 1.6/4.0 609 426 1.5/3.5 465 331 1.5/3.5 361 261 1.5/3.5 285 210 1.5/3.5 226 171 1.5/3.5 182 141 1.5/3.5 16" 5,866 * 4.5/11.3 4,667 * 4.3/10.6 4,369 * 4.2/10.5 3,476 3,443 4.0/10.0 2,818 2,264 3.8/9.5 2,019 1,432 3.2/8.1 1,518 1,035 2.7/6.8 1,207 828 2.4/5.9 909 629 2.0/4.9 698 488 1.7/4.2 545 387 1.5/3.6 432 311 1.5/3.5 346 254 1.5/3.5 280 210 1.5/3.5 18" 5,866 * 4.5/11.3 4,934 * 4.5/11.3 4,685 * 4.5/11.3 3,898 * 4.5/11.3 3,320 3,122 4.5/11.3 2,526 1,991 4.0/10.1 2,001 1,445 3.6/9.0 1,700 1,159 3.3/8.3 1,285 883 2.8/6.9 992 687 2.4/5.9 779 545 2.0/5.1 620 439 1.8/4.4 499 359 1.5/3.9 406 297 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 21 Snow Roof Load Tables How to Use This Table 1.Calculate total load (neglect beam weight) on the beam or header in pounds per linear foot (plf). 2.Select appropriate Span (center-to-center of bearing). 3.Scan horizontally to find the proper width, and a depth with a capacity that exceeds actual total load. 4.Review bearing length requirements to ensure adequacy. Also see General Notes on page 23. TimberStrand® LSL: Roof—Snow Load Area 115% (PLF) Span 1.3E Grade Condition Total Load 3' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 4' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 5' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 6' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 7' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 8' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 9'-6" Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 10' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 12' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 14' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 16'-6" Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 18'-6" Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 20' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 24' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 28' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) 4 3 ⁄8" 51 ⁄ 2 " 1,770 2,740 */1,420 */2,548 1.5/3.5 1.7/4.3 994 1,539 978/652 */1215 1.5/3.5 1.5/3.5 634 983 522/348 */662 1.5/3.5 1.5/3.5 318 615 309/206 596/397 1.5/3.5 1.5/3.5 172 337 */132 */256 1.5/3.5 1.5/3.5 100 198 */89 */174 1.5/3.5 1.5/3.5 98 */* 1.5/3.5 79 */* 1.5/3.5 31 ⁄ 2" Width 71 ⁄4" 8 5 ⁄8" 4,644 6,469 */* */* 2.9/7.3 4.1/10.2 2,609 3,635 */2477 */* 2.2/5.5 3.1/7.7 1,667 2,323 */1,399 */2,189 1.8/4.4 2.4/6.1 1,155 1,611 */857 */1,367 1.5/3.7 2.0/5.1 743 1,181 */560 */904 1.5/3.5 1.7/4.4 443 902 */384 */626 1.5/3.5 1.5/3.8 225 637 580/386 */* 1.5/3.5 1.5/3.5 183 574 501/334 */* 1.5/.3.5 1.5/3.5 86 387 297/198 */* 1.5/3.5 1.5/3.5 244 189/126 1.5/3.5 147 117/78 1.5/3.5 102 83/56 1.5/3.5 80 66/44 1.5/3.5 91 ⁄4" 7,128 */* 4.5/11.3 4,154 */* 3.5/8.7 2,655 */2,605 2.8/7.0 1,841 */1,641 2.3/5.8 1,350 */1,092 2.0/5.0 1,031 */759 1.7/4.4 728 706/470 1.5/3.7 656 611/407 1.5/3.5 453 362/241 1.5/3.5 300 232/154 1.5/3.5 182 143/95 1.5/3.5 127 102/68 1.5/3.5 99 81/54 1.5/3.5 53 47/31 1.5/3.5 1.55E Grade 51 ⁄ 2" Plank Orientation 111 ⁄4" 31 ⁄ 2 " 91⁄4" 7,128 1,393 3,479 */* */1,224 */* 4.5/11.3 1.5/3.5 3.8/9.4 5,343 997 2,219 820/547 */* */* 4.5/11.3 1.5/3.5 3.2/8.0 3,860 534 1,629 432/288 */* */1,553 4.1/10.2 1.5/3.5 3.0/7.3 2,677 259 1,260 254/169 */* */978 3.4/8.5 1.5/3.5 2.8/6.8 1,963 138 924 */1,828 */107 */651 2.9/7.3 1.5/3.5 2.4/5.9 1,500 79 706 679/453 */1,290 */72 2.5/6.4 1.5/3.5 2.1/5.1 1,061 499 421/280 */811 2.1/5.4 1.8/4.3 956 450 364/242 */704 2.0/5.1 1.7/4.1 660 283 634/423 216/144 1.7/4.2 1.5/3.5 482 179 409/272 138/92 1.5/3.6 1.5/3.5 327 109 254/169 85/57 1.5/3.5 1.5/3.5 231 76 182/121 61/40 1.5/3.5 1.5/3.5 181 59 145/96 48/32 1.5/3.5 1.5/3.5 101 84/56 1.5/3.5 60 53/35 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 22 91⁄ 2 " 3,642 */* 3.9/9.8 2,307 */* 3.3/8.3 1,688 */1,658 3.0/7.6 1,326 */1,048 2.9/7.1 973 */699 2.4/6.1 743 731/487 2.1/5.4 525 453/302 1.8/4.5 474 392/261 1.7/4.3 306 233/155 1.5/3.5 194 149/99 1.5/3.5 118 92/61 1.5/3.5 83 66/44 1.5/3.5 64 52/35 1.5/3.5 13⁄4" Width 111⁄4" 4,192 */* 4.5/11.3 2,988 */* 4.3/10.7 2,132 */* 3.9/9.6 1,657 */1,605 3.6/9.0 1,344 */1,089 3.4/8.5 1,028 */769 3.0/7.4 727 725/483 2.5/6.3 655 630/420 2.4/6.0 453 378/252 2.0/5.0 318 243/162 1.7/4.1 196 151/101 1.5/3.5 138 108/72 1.5/3.5 109 86/57 1.5/3.5 61 50/33 1.5/3.5 117⁄ 8" 4,192 */* 4.5/11.3 3,142 */* 4.5/11.3 2,306 */* 4.1/10.3 1,782 */* 3.8/9.6 1,452 */1,250 3.6/9.1 1,140 */886 3.3/8.2 806 */560 2.8/6.9 727 */487 2.6/6.6 503 440/293 2.2/5.5 367 284/189 1.9/4.7 230 177/118 1.5/3.5 163 127/84 1.5/3.5 128 101/67 1.5/3.5 72 59/39 1.5/3.5 14" 4,192 */* 4.5/11.3 3,142 */* 4.5/11.3 2,512 */* 4.5/11.3 2,092 */* 4.5/11.3 1,792 */* 4.5/11.3 1,511 */1352 4.3/10.9 1,105 */870 3.8/9.4 996 */760 3.6/9.0 690 */464 3.0/7.5 504 453/302 2.6/6.4 361 284/189 2.2/5.4 265 205/136 1.8/4.5 210 163/109 1.6/3.9 120 96/64 1.5/3.5 Snow Roof Load Tables General Notes ■ ■ Table is based on: –Uniform loads (beam weight considered). – More restrictive of simple or continuous span. –Deflection criteria of L/180 total load. For stiffer deflection criteria, use L/240 values for total load deflection. For door and window applications, Weyerhaeuser recommends using the L/360 value for a live load deflection limit and the L/240 value for a total load limit. Also see How to Use This Table on page 22 and General Assumptions on page 5. TimberStrand® LSL: Roof—Snow Load Area 115% (PLF) continued Span Condition Total Load 3' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 4' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 5' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 6' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 7' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 8' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 9'-6" Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 10' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 12' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 14' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 16'-6" Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 18'-6" Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 20' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 24' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 28' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) 1.55E Grade 31⁄2" Width 91⁄4" 91⁄ 2 " 111⁄4" 117⁄ 8" 6,958 7,284 8,382 8,382 */* */* */* */* 3.8/9.4 3.9/9.8 4.5/11.3 4.5/11.3 4,439 4,615 5,976 6,282 */* */* */* */* 3.2/8.0 3.3/8.3 4.3/10.7 4.5/11.3 3,258 3,376 4,265 4,612 */3,106 */3,316 */* */* 3.0/7.3 3.0/7.6 3.9/9.6 4.1/10.3 2,521 2,652 3,315 3,565 */1,957 */2097 */3,210 */* 2.8/6.8 2.9/7.1 3.6/9.0 3.8/9.6 1,849 1,946 2,689 2,904 */1,302 */1,399 */2,179 */2,501 2.4/5.9 2.4/6.1 3.4/8.5 3.6/9.1 1,413 1,487 2,056 2,280 1,359/906 1,462/974 */1,538 */1,773 2.1/5.1 2.1/5.4 3.0/7.4 3.3/8.2 999 1,051 1,454 1,613 842/561 907/605 1,451/967 */1,121 1.8/4.3 1.8/4.5 2.5/6.3 2.8/6.9 901 948 1,311 1,454 728/485 785/523 1,260/840 */974 1.7/4.1 1.7/4.3 2.4/6.0 2.6/6.6 566 612 907 1,006 432/288 467/311 756/504 881/587 1.5/3.5 1.5/3.5 2.0/5.0 2.2/5.5 359 388 637 735 276/184 299/199 487/325 569/379 1.5/3.5 1.5/3.5 1.7/4.1 1.9/4.7 218 236 392 460 171/114 185/123 303/202 354/236 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 152 166 277 326 122/81 132/88 217/144 254/169 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 119 129 218 257 97/64 105/70 172/115 202/135 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 65 71 122 145 56/37 61/40 101/67 118/79 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 73 87 64/42 75/50 1.5/3.5 1.5/3.5 14" 8,382 */* 4.5/11.3 6,282 */* 4.5/11.3 5,022 */* 4.5/11.3 4,182 */* 4.5/11.3 3,582 */* 4.5/11.3 3,022 */2,705 4.3/10.9 2,211 */1,740 3.8/9.4 1,993 */1,520 3.6/9.0 1,380 */928 3.0/7.5 1,009 907/605 2.6/6.4 722 569/379 2.2/5.4 531 410/273 1.8/4.5 421 327/218 1.6/3.9 241 192/128 1.5/3.5 147 122/81 1.5/3.5 51⁄4" Width (2- or 3-ply) 16" 91⁄4" 91⁄ 2 " 111⁄4" 117⁄ 8" 8,382 10,437 10,926 12,573 12,573 */* */* */* */* */* 4.5/11.3 3.8/9.4 3.9/9.8 4.5/11.3 4.5/11.3 6,282 6,659 6,923 8,965 9,423 */* */* */* */* */* 4.5/11.3 3.2/8.0 3.3/8.3 4.3/10.7 4.5/11.3 5,022 4,887 5,064 6,398 6,919 */* */4,659 */4,975 */* */* 4.5/11.3 3.0/7.3 3.0/7.6 3.9/9.6 4.1/10.3 4,182 3,781 3,979 4,972 5,348 */* */2,936 */3,146 */4,816 */* 4.5/11.3 2.8/6.8 2.9/7.1 3.6/9.0 3.8/9.6 3,582 2,774 2,919 4,034 4,357 */* */1,954 */2,098 */3,269 */3,752 4.5/11.3 2.4/5.9 2.4/6.1 3.4/8.5 3.6/9.1 3,132 2,120 2,231 3,084 3,420 2,038/1,359 2,193/1,462 */2,307 */* */2,660 4.5/11.3 2.1/5.1 2.1/5.4 3.0/7.4 3.3/8.2 2,635 1,499 1,577 2,181 2,419 */2,456 1,263/842 1,361/907 2,176/1,451 */1,681 4.5/11.3 1.8/4.3 1.8/4.5 2.5/6.3 2.8/6.9 2,502 1,351 1,422 1,967 2,182 */2,154 1,092/728 1,178/785 1,890/1,260 */1,462 4.5/11.3 1.7/4.1 1.7/4.3 2.4/6.0 2.6/6.6 1,782 850 918 1,360 1,509 649/432 700/467 1,135/756 1,322/881 */1,334 3.9/9.7 1.5/3.5 1.5/3.5 2.0/5.0 2.2/5.5 1,305 538 582 956 1,103 415/276 448/299 731/487 854/569 */877 3.4/8.3 1.5/3.5 1.5/3.5 1.7/4.1 1.9/4.7 934 327 354 588 690 832/555 256/171 277/185 455/303 532/354 2.9/7.1 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 739 229 249 416 489 601/401 183/122 198/132 326/217 381/254 2.6/6.3 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 624 179 194 327 385 481/320 145/97 157/105 259/172 304/202 2.3/5.8 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 361 98 106 183 217 284/189 84/56 91/61 151/101 177/118 1.7/4.1 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 224 56 61 109 130 181/120 53/35 58/38 96/64 112/75 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 23 14" 12,573 */* 4.5/11.3 9,423 */* 4.5/11.3 7,533 */* 4.5/11.3 6,273 */* 4.5/11.3 5,373 */* 4.5/11.3 4,534 */4,058 4.3/10.9 3,316 */2,610 3.8/9.4 2,990 */2,280 3.6/9.0 2,070 */1,393 3.0/7.5 1,514 1,361/907 2.6/6.4 1,084 854/569 2.2/5.4 797 615/410 1.8/4.5 631 491/327 1.6/3.9 361 288/192 1.5/3.5 221 183/122 1.5/3.5 16" 12,573 */* 4.5/11.3 9,423 */* 4.5/11.3 7,533 */* 4.5/11.3 6,273 */* 4.5/11.3 5,373 */* 4.5/11.3 4,698 */* 4.5/11.3 3,952 */3,684 4.5/11.3 3,753 */3,232 4.5/11.3 2,674 */2,001 3.9/9.7 1,957 */1,316 3.4/8.3 1,402 1,248/832 2.9/7.1 1,109 902/601 2.6/6.3 936 722/481 2.3/5.8 542 426/284 1.7/4.1 336 271/181 1.5/3.5 Snow Roof Load Tables How to Use This Table 1.Calculate total load (neglect beam weight) on the beam or header in pounds per linear foot (plf). 2. Select appropriate Span (center-to-center of bearing). 3.Scan horizontally to find the proper width, and a depth with a capacity that exceeds actual total load. 4.Review bearing length requirements to ensure adequacy. Also see General Notes on page 25. 1.9E Microllam® LVL: Roof—Snow Load Area 115% (PLF) Span Condition Total Load 6' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 8' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 9'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 10' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 12' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 14' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 16'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 18'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 20' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 22' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 24' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 26' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 28' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 30' Deflection L/240 Min. End/Int. Bearing (in.) 51 ⁄ 2 " 451 435 1.5/3.5 146 * 1.5/3.5 73 * 1.5/3.5 59 * 1.5/3.5 71 ⁄4" 877 * 2.0/5.0 326 * 1.5/3.5 166 * 1.5/3.5 135 * 1.5/3.5 64 * 1.5/3.5 91 ⁄4" 1,182 * 2.7/6.8 800 * 2.5/6.1 566 516 2.1/5.2 510 446 2.0/4.9 348 265 1.6/4.0 221 169 1.5/3.5 135 104 1.5/3.5 95 74 1.5/3.5 74 59 1.5/3.5 55 44 1.5/3.5 13 ⁄4" Width 91 ⁄ 2 " 1,223 * 2.8/7.0 841 * 2.6/6.4 595 556 2.2/5.4 536 481 2.1/5.2 371 286 1.7/4.3 239 183 1.5/3.5 146 113 1.5/3.5 103 81 1.5/3.5 81 64 1.5/3.5 59 48 1.5/3.5 111 ⁄4" 1,523 * 3.5/8.7 1,053 * 3.2/8.1 816 * 3.0/7.4 736 * 2.8/7.1 509 463 2.4/5.9 373 298 2.0/5.0 242 185 1.6/3.9 171 133 1.5/3.5 135 106 1.5/3.5 101 80 1.5/3.5 76 61 1.5/3.5 59 48 1.5/3.5 117⁄ 8" 1,638 * 3.8/9.4 1,126 * 3.5/8.6 903 * 3.3/8.2 814 * 3.1/7.8 564 540 2.6/6.5 412 348 2.2/5.6 283 217 1.8/4.6 201 155 1.5/3.7 159 124 1.5/3.5 119 93 1.5/3.5 90 72 1.5/3.5 70 57 1.5/3.5 55 46 1.5/3.5 14" 51 ⁄ 2 " 1,961 902 870 * 4.5/11.3 1.5/3.5 1,389 292 * * 4.3/10.6 1.5/3.5 1,114 146 * * 4.1/10.2 1.5/3.5 1,045 118 * * 4.0/10.0 1.5/3.5 767 54 * * 3.5/8.9 1.5/3.5 562 556 3.0/7.6 402 349 2.6/6.4 318 251 2.3/5.7 260 200 2.0/5.1 195 152 1.7/4.2 150 117 1.5/3.6 117 93 1.5/3.5 92 74 1.5/3.5 74 61 1.5/3.5 71 ⁄4" 1,755 * 2.0/5.0 652 * 1.5/3.5 332 * 1.5/3.5 270 * 1.5/3.5 128 * 1.5/3.5 66 * 1.5/3.5 31 ⁄ 2" Width (2-ply) 91 ⁄4" 91 ⁄ 2 " 2,365 2,446 * * 2.7/6.8 2.8/7.0 1,601 1,682 * * 2.5/6.1 2.6/6.4 1,132 1,190 1,032 1,112 2.1/5.2 2.2/5.4 1,021 1,073 893 963 2.0/4.9 2.1/5.2 697 742 530 572 1.6/4.0 1.7/4.3 443 479 339 366 1.5/3.5 1.5/3.5 270 292 209 227 1.5/3.5 1.5/3.5 190 206 149 162 1.5/3.5 1.5/3.5 149 162 128 119 1.5/3.5 1.5/3.5 110 119 89 97 1.5/3.5 1.5/3.5 83 90 69 75 1.5/3.5 1.5/3.5 63 69 54 59 1.5/3.5 1.5/3.5 53 47 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 24 111 ⁄4" 3,047 * 3.5/8.7 2,106 * 3.2/8.1 1,633 * 3.0/7.4 1,473 * 2.8/7.1 1,019 927 2.4/5.9 745 597 2.0/5.0 484 371 1.6/3.9 343 266 1.5/3.5 271 212 1.5/3.5 202 160 1.5/3.5 153 123 1.5/3.5 118 97 1.5/3.5 93 78 1.5/3.5 73 63 1.5/3.5 117⁄ 8" 3,277 * 3.8/9.4 2,252 * 3.5/8.6 1,807 * 3.3/8.2 1,629 * 3.1/7.8 1,128 1,080 2.6/6.5 825 697 2.2/5.6 567 435 1.8/4.6 403 311 1.5/3.7 319 248 1.5/3.5 238 187 1.5/3.5 181 145 1.5/3.5 140 114 1.5/3.5 110 92 1.5/3.5 88 75 1.5/3.5 Snow Roof Load Tables General Notes ■ Table is based on: –Uniform loads (beam weight considered). – More restrictive of simple or continuous span. –Deflection criteria of L/180 total load. For stiffer deflection criteria, use L/240 values for total load deflection. Also see How to Use This Table on page 24 and General Assumptions on page 5. 1.9E Microllam® LVL: Roof—Snow Load Area 115% (PLF) continued Span Condition Total Load 6' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 8' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 9'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 10' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 12' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 14' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 16'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 18'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 20' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 22' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 24' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 26' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 28' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 30' Deflection L/240 Min. End/Int. Bearing (in.) 14" 3,917 * 4.5/11.3 2,778 * 4.3/10.6 2,229 * 4.1/10.2 2,091 * 4.0/10.0 1,535 * 3.5/8.9 1,124 1,112 3.0/7.6 805 698 2.6/6.4 637 502 2.3/5.7 520 401 2.0/5.1 391 304 1.7/4.2 300 235 1.5/3.6 234 186 1.5/3.5 185 149 1.5/3.5 148 122 1.5/3.5 31 ⁄ 2" Width (2-ply) 16" 18" 3,917 3,917 * * 4.5/11.3 4.5/11.3 2,932 2,932 * * 4.5/11.3 4.5/11.3 2,466 2,466 * * 4.5/11.3 4.5/11.3 2,342 2,342 * * 4.5/11.3 4.5/11.3 1,948 1,948 * * 4.5/11.3 4.5/11.3 1,444 1,667 * * 3.9/9.7 4.5/11.3 1,035 1,291 1,020 * 3.3/8.3 4.1/10.3 820 1,023 737 * 2.9/7.4 3.7/9.2 699 872 590 826 2.7/6.8 3.4/8.5 575 718 448 629 2.5/6.2 3.1/7.7 448 600 348 490 2.1/5.3 2.8/7.1 351 499 275 388 1.8/4.6 2.6/6.4 279 399 222 313 1.6/3.9 2.2/5.6 225 323 181 256 1.5/3.5 2.0/4.9 20" 3,917 * 4.5/11.3 2,932 * 4.5/11.3 2,466 * 4.5/11.3 2,342 * 4.5/11.3 1,948 * 4.5/11.3 1,667 * 4.5/11.3 1,411 * 4.5/11.3 1,247 * 4.5/11.2 1,064 * 4.1/10.3 876 850 3.8/9.4 732 663 3.4/8.6 621 527 3.2/7.9 533 425 3.0/7.4 444 348 2.7/6.6 51 ⁄ 2 " 1,353 1,305 1.5/3.5 438 * 1.5/3.5 219 * 1.5/3.5 177 * 1.5/3.5 82 * 1.5/3.5 71 ⁄4" 2,632 * 2.0/5.0 978 * 1.5/3.5 498 * 1.5/3.5 406 * 1.5/3.5 193 * 1.5/3.5 100 * 1.5/3.5 91 ⁄4" 3,547 * 2.7/6.8 2,401 * 2.5/6.1 1,698 1,548 2.1/5.2 1,531 1,339 2.0/4.9 1,046 795 1.6/4.0 664 509 1.5/3.5 405 314 1.5/3.5 285 224 1.5/3.5 224 178 1.5/3.5 165 134 1.5/3.5 124 104 1.5/3.5 95 82 1.5/3.5 73 65 1.5/3.5 57 53 1.5/3.5 91 ⁄ 2 " 3,669 * 2.8/7.0 2,524 * 2.6/6.4 1,785 1,669 2.2/5.4 1,610 1,444 2.1/5.2 1,113 859 1.7/4.3 719 550 1.5/3.5 439 340 1.5/3.5 309 243 1.5/3.5 243 193 1.5/3.5 179 145 1.5/3.5 135 112 1.5/3.5 103 88 1.5/3.5 80 71 1.5/3.5 62 58 1.5/3.5 51 ⁄4" Width (3-ply) 111 ⁄4" 117⁄ 8" 4,571 4,916 * * 3.5/8.7 3.8/9.4 3,159 3,378 * * 3.2/8.1 3.5/8.6 2,450 2,710 * * 3.0/7.4 3.3/8.2 2,209 2,444 * * 2.8/7.1 3.1/7.8 1,529 1,692 1,391 1,620 2.4/5.9 2.6/6.5 1,118 1,238 896 1,046 2.0/5.0 2.2/5.6 726 851 557 652 1.6/3.9 1.8/4.6 515 605 399 467 1.5/3.5 1.5/3.7 406 478 318 372 1.5/3.5 1.5/3.5 303 357 240 281 1.5/3.5 1.5/3.5 230 272 185 218 1.5/3.5 1.5/3.5 178 211 146 172 1.5/3.5 1.5/3.5 139 166 117 138 1.5/3.5 1.5/3.5 110 132 95 112 1.5/3.5 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 25 14" 5,875 * 4.5/11.3 4,168 * 4.3/10.6 3,344 * 4.1/10.2 3,137 * 4.0/10.0 2,303 * 3.5/8.9 1,686 1,669 3.0/7.6 1,208 1,047 2.6/6.4 956 754 2.3/5.7 781 602 2.0/5.1 586 456 1.7/4.2 450 353 1.5/3.6 351 279 1.5/3.5 278 224 1.5/3.5 223 183 1.5/3.5 16" 5,875 * 4.5/11.3 4,399 * 4.5/11.3 3,699 * 4.5/11.3 3,513 * 4.5/11.2 2,922 * 4.5/11.2 2,166 * 3.9/9.7 1,552 1,530 3.3/8.3 1,230 1,106 2.9/7.4 1,048 885 2.7/6.8 862 672 2.5/6.2 672 522 2.1/5.3 527 413 1.8/4.6 419 333 1.6/3.9 338 271 1.5/3.5 18" 5,875 * 4.5/11.3 4,399 * 4.5/11.3 3,699 * 4.5/11.3 3,513 * 4.5/11.2 2,922 * 4.5/11.2 2,500 * 4.5/11.2 1,936 * 4.1/10.3 1,534 * 3.7/9.2 1,309 1,239 3.4/8.5 1,077 944 3.1/7.7 900 735 2.8/7.1 749 583 2.6/6.4 599 470 2.2/5.6 484 384 2.0/4.9 20" 5,875 * 4.5/11.3 4,399 * 4.5/11.3 3,699 * 4.5/11.3 3,513 * 4.5/11.2 2,922 * 4.5/11.2 2,500 * 4.5/11.2 2,117 * 4.5/11.2 1,871 * 4.5/11.2 1,596 * 4.1/10.3 1,314 1,275 3.8/9.4 1,099 995 3.4/8.6 932 790 3.2/7.9 799 638 3.0/7.4 666 522 2.7/6.6 Snow Roof Load Tables How to Use This Table 1.Calculate total load (neglect beam weight) on the beam or header in pounds per linear foot (plf). 2.Select appropriate Span (center-to-center of bearing). 3.Scan horizontally to find the proper width, and a depth with a capacity that exceeds actual total load. 4.Review bearing length requirements to ensure adequacy. Also see General Notes on page 27. 2.0E Parallam® PSL: Roof—Snow Load Area 115% (PLF) Span Condition Total Load 8' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 9'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 10' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 12' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 14' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 16'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 18'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 20' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 22' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 24' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 26' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 28' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 30' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 32' Deflection L/240 Min. End/Int. Bearing (in.) 91 ⁄4" 91 ⁄ 2 " 111 ⁄4" 1,691 * 2.6/6.5 1,255 1,086 2.3/5.7 1,132 940 2.2/5.4 734 558 1.7/4.3 466 357 1.5/3.5 284 220 1.5/3.5 200 157 1.5/3.5 157 125 1.5/3.5 115 94 1.5/3.5 87 73 1.5/3.5 66 57 1.5/3.5 51 46 1.5/3.5 1,746 * 2.7/6.7 1,320 1,171 2.4/6.0 1,190 1,013 2.3/5.7 793 602 1.8/4.6 504 386 1.5/3.5 308 238 1.5/3.5 217 170 1.5/3.5 170 135 1.5/3.5 126 102 1.5/3.5 95 79 1.5/3.5 72 62 1.5/3.5 56 50 1.5/3.5 2,142 * 3.3/8.2 1,738 * 3.2/7.9 1,635 1,626 3.1/7.8 1,135 976 2.6/6.6 826 629 2.2/5.6 509 391 1.6/4.1 361 280 1.5/3.5 285 223 1.5/3.5 212 168 1.5/3.5 161 130 1.5/3.5 124 102 1.5/3.5 97 82 1.5/3.5 77 67 1.5/3.5 61 55 1.5/3.5 31⁄ 2" Width 117⁄ 8" 14" 2,291 2,826 * * 3.5/8.8 4.3/10.8 1,854 2,268 * * 3.4/8.4 4.1/10.3 1,743 2,127 * * 3.3/8.4 4.1/10.2 1,258 1,704 1,137 * 2.9/7.3 3.9/9.8 921 1,259 734 1,171 2.5/6.2 3.4/8.5 597 902 457 735 1.9/4.8 2.9/7.2 424 690 328 529 1.5/3.9 2.5/6.2 335 548 261 422 1.5/3.5 2.1/5.4 250 411 197 320 1.5/3.5 1.8/4.5 191 315 153 248 1.5/3.5 1.5/3.8 148 246 120 196 1.5/3.5 1.5/3.5 116 195 97 157 1.5/3.5 1.5/3.5 92 156 79 128 1.5/3.5 1.5/3.5 74 126 65 106 1.5/3.5 1.5/3.5 16" 2,933 * 4.5/11.3 2,467 * 4.5/11.3 2,342 * 4.5/11.3 1,949 * 4.5/11.3 1,623 * 4.4/10.9 1,163 1,074 3.7/9.3 922 776 3.3/8.3 786 621 3.1/7.7 611 472 2.6/6.6 471 366 2.2/5.6 369 290 1.9/4.8 294 233 1.7/4.2 236 190 1.5/3.6 192 157 1.5/3.5 18" 2,933 * 4.5/11.3 2,467 * 4.5/11.3 2,342 * 4.5/11.3 1,949 * 4.5/11.3 1,667 * 4.5/11.3 1,412 * 4.5/11.3 1,154 1,084 4.1/10.3 984 869 3.8/9.6 810 662 3.5/8.7 668 515 3.1/7.9 525 409 2.7/6.8 420 329 2.3/5.9 339 269 2.1/5.1 277 223 1.8/4.5 91 ⁄4" 91⁄ 2 " 111 ⁄4" 2,537 * 2.6/6.5 1,883 1,630 2.3/5.7 1,698 1,410 2.2/5.4 1,101 837 1.7/4.3 699 535 1.5/3.5 426 331 1.5/3.5 300 236 1.5/3.5 235 188 1.5/3.5 173 141 1.5/3.5 130 109 1.5/3.5 100 86 1.5/3.5 77 69 1.5/3.5 60 56 1.5/3.5 2,619 * 2.7/6.7 1,980 1,757 2.4/6.0 1,786 1,520 2.3/5.7 1,190 904 1.8/4.6 756 579 1.5/3.5 462 358 1.5/3.5 325 256 1.5/3.5 255 203 1.5/3.5 189 153 1.5/3.5 142 118 1.5/3.5 109 93 1.5/3.5 84 75 1.5/3.5 65 61 1.5/3.5 51 50 1.5/3.5 3,213 * 3.3/8.2 2,607 * 3.2/7.9 2,453 2,439 3.1/7.8 1,703 1,464 2.6/6.6 1,240 943 2.2/5.6 764 587 1.6/4.1 542 420 1.5/3.5 427 334 1.5/3.5 318 252 1.5/3.5 242 195 1.5/3.5 187 154 1.5/3.5 146 123 1.5/3.5 116 101 1.5/3.5 92 83 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 26 51 ⁄4" Width 117⁄ 8" 14" 3,436 4,240 * * 3.5/8.8 4.3/10.8 2,781 3,402 * * 3.4/8.4 4.1/10.3 2,615 3,191 * * 3.3/8.4 4.1/10.2 1,887 2,557 1,706 * 2.9/7.3 3.9/9.8 1,381 1,889 1,102 1,757 2.5/6.2 3.4/8.5 896 1,353 686 1,103 1.9/4.8 2.9/7.2 637 1,035 492 794 1.5/3.9 2.5/6.2 503 822 392 633 1.5/3.5 2.1/5.4 375 617 296 480 1.5/3.5 1.8/4.5 286 473 229 372 1.5/3.5 1.5/3.8 222 369 181 294 1.5/3.5 1.5/3.5 174 292 145 236 1.5/3.5 1.5/3.5 138 234 118 193 1.5/3.5 1.5/3.5 111 189 97 159 1.5/3.5 1.5/3.5 16" 4,400 * 4.5/11.3 3,700 * 4.5/11.3 3,514 * 4.5/11.3 2,923 * 4.5/11.3 2,434 * 4.4/10.9 1,745 1,611 3.7/9.3 1,383 1,164 3.3/8.3 1,179 931 3.1/7.7 917 708 2.6/6.6 707 550 2.2/5.6 554 435 1.9/4.8 441 350 1.7/4.2 355 286 1.5/3.6 289 236 1.5/3.5 18" 4,400 * 4.5/11.3 3,700 * 4.5/11.3 3,514 * 4.5/11.3 2,923 * 4.5/11.3 2,501 * 4.5/11.3 2,118 * 4.5/11.2 1,731 1,626 4.1/10.3 1,476 1,304 3.8/9.6 1,215 994 3.5/8.7 1,002 773 3.1/7.9 788 613 2.7/6.8 630 494 2.3/5.9 509 404 2.1/5.1 416 334 1.8/4.5 Snow Roof Load Tables General Notes ■ Table is based on: –Uniform loads (beam weight considered). – More restrictive of simple or continuous span. –Deflection criteria of L/180 total load. For stiffer deflection criteria, use L/240 values for total load deflection. Also see How to Use This Table on page 26 and General Assumptions on page 5. 2.0E Parallam® PSL: Roof—Snow Load Area 115% (PLF) continued Span Condition Total Load 8' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 9'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 10' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 12' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 14' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 16'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 18'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 20' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 22' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 24' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 26' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 28' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 30' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 32' Deflection L/240 Min. End/Int. Bearing (in.) 91 ⁄4" 3,383 * 2.6/6.5 2,511 2,173 2.3/5.7 2,264 1,880 2.2/5.4 1,468 1,116 1.7/4.3 932 714 1.5/3.5 569 441 1.5/3.5 400 315 1.5/3.5 314 250 1.5/3.5 231 189 1.5/3.5 174 146 1.5/3.5 133 115 1.5/3.5 102 92 1.5/3.5 80 75 1.5/3.5 62 62 1.5/3.5 91⁄2" 3,492 * 2.7/6.7 2,641 2,342 2.4/6.0 2,381 2,027 2.3/5.7 1,586 1,205 1.8/4.6 1,008 772 1.5/3.5 616 477 1.5/3.5 434 341 1.5/3.5 340 271 1.5/3.5 252 204 1.5/3.5 190 158 1.5/3.5 145 124 1.5/3.5 112 100 1.5/3.5 87 81 1.5/3.5 68 67 1.5/3.5 111 ⁄4" 4,285 * 3.3/8.2 3,477 * 3.2/7.9 3,271 3,252 3.1/7.8 2,271 1,953 2.6/6.6 1,653 1,258 2.2/5.6 1,019 782 1.6/4.1 723 560 1.5/3.5 570 446 1.5/3.5 425 337 1.5/3.5 323 260 1.5/3.5 249 205 1.5/3.5 195 165 1.5/3.5 154 134 1.5/3.5 123 111 1.5/3.5 7" Width 117⁄ 8" 4,582 * 3.5/8.8 3,709 * 3.4/8.4 3,487 * 3.3/8.4 2,517 2,274 2.9/7.3 1,842 1,469 2.5/6.2 1,195 915 1.9/4.8 849 656 1.5/3.9 671 523 1.5/3.5 501 395 1.5/3.5 382 306 1.5/3.5 296 241 1.5/3.5 232 194 1.5/3.5 184 158 1.5/3.5 148 130 1.5/3.5 14" 5,653 * 4.3/10.8 4,536 * 4.1/10.3 4,255 * 4.1/10.2 3,409 * 3.9/9.8 2,519 2,342 3.4/8.5 1,805 1,470 2.9/7.2 1,381 1,058 2.5/6.2 1,096 845 2.1/5.4 823 640 1.8/4.5 631 496 1.5/3.8 492 392 1.5/3.5 390 315 1.5/3.5 312 257 1.5/3.5 253 212 1.5/3.5 16" 5,866 * 4.5/11.3 4,934 * 4.5/11.3 4,685 * 4.5/11.3 3,898 * 4.5/11.3 3,246 * 4.4/10.9 2,327 2,148 3.7/9.3 1,844 1,553 3.3/8.3 1,572 1,242 3.1/7.7 1,223 944 2.6/6.6 942 733 2.2/5.6 739 580 1.9/4.8 588 467 1.7/4.2 473 381 1.5/3.6 385 315 1.5/3.5 18" 5,866 * 4.5/11.3 4,934 * 4.5/11.3 4,685 * 4.5/11.3 3,898 * 4.5/11.3 3,335 * 4.5/11.3 2,824 * 4.5/11.3 2,308 2,168 4.1/10.3 1,969 1,739 3.8/9.6 1,620 1,325 3.5/8.7 1,336 1,031 3.1/7.9 1,051 818 2.7/6.8 840 659 2.3/5.9 679 539 2.1/5.1 555 446 1.8/4.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 27 NON-SNOW ROOF LOAD TABLES How to Use This Table 1.Calculate total load (neglect beam weight) on the beam or header in pounds per linear foot (plf). 2.Select appropriate Span (center-to-center of bearing). 3.Scan horizontally to find the proper width, and a depth with a capacity that exceeds actual total load. 4.Review bearing length requirements to ensure adequacy. Also see General Notes on page 29. TimberStrand® LSL: Roof—Non-Snow Load Area 125% (PLF) Span 1.3E Grade Condition Total Load 3' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 4' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 5' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 6' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 7' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 8' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 9'-6" Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 10' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 12' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 14' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 16'-6" Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 18'-6" Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 20' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 24' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 28' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) 31 ⁄ 2 " 51 ⁄ 2 " 4 3 ⁄8" 1,924 2,979 */1,420 */2,548 1.5/3.5 1.9/4.7 1,080 1,673 978/652 */1,215 1.5/3.5 1.5/3.5 648 1,069 522/348 993/662 1.5/3.5 1.5/3.5 318 615 309/206 596/397 1.5/3.5 1.5/3.5 172 337 */132 */256 1.5/3.5 1.5/3.5 100 198 */89 */174 1.5/3.5 1.5/3.5 98 */* 1.5/3.5 79 */* 1.5/3.5 71 ⁄4" 5,048 */4,885 3.2/8.0 2,836 */2,477 2.4/6.0 1,813 */1,399 1.9/4.8 1,256 */857 1.6/4.0 743 */560 1.5/3.5 443 */384 1.5/3.5 225 */* 1.5/3.5 183 */* 1.5/3.5 86 */* 1.5/3.5 Width 85 ⁄ 8" 7,033 */* 4.4/11.1 3,952 */3,765 3.3/8.3 2,526 */2,189 2.7/6.7 1,752 */1,367 2.2/5.5 1,285 */904 1.9/4.8 981 939/626 1.7/4.2 693 580/386 1.5/3.5 625 501/334 1.5/3.5 387 297/198 1.5/3.5 244 189/126 1.5/3.5 147 117/78 1.5/3.5 102 83/56 1.5/3.5 80 66/44 1.5/3.5 1.55E Grade 51 ⁄ 2 " 91 ⁄4" 7,128 */* 4.5/11.3 4,516 */4,423 3.8/9.5 2,887 */2,605 3.0/7.6 2,002 */1,641 2.5/6.3 1,468 */1,092 2.2/5.4 1,122 */759 1.9/4.8 793 706/470 1.6/4.0 714 611/407 1.5/3.8 474 362/241 1.5/3.5 300 232/154 1.5/3.5 182 143/95 1.5/3.5 127 102/68 1.5/3.5 99 81/54 1.5/3.5 53 47/31 1.5/3.5 111 ⁄4" 7,128 */* 4.5/11.3 5,343 */* 4.5/11.3 4,197 */4,154 4.4/11.1 2,911 */2,692 3.7/9.2 2,135 */1,828 3.2/7.9 1,632 */1,290 2.8/6.9 1,154 */811 2.3/5.8 1,040 */704 2.2/5.5 719 634/423 1.8/4.6 525 409/272 1.6/3.9 327 254/169 1.5/3.5 231 182/121 1.5/3.5 181 145/96 1.5/3.5 101 84/56 1.5/3.5 60 53/35 1.5/3.5 Plank Orientation 13 ⁄4" Width 31 ⁄ 2 " 91 ⁄4" 91 ⁄ 2 " 111 ⁄4" 1,514 3,782 3,959 4,192 */1,224 */* */* */* 1.5/3.5 4.1/10.2 4.2/10.6 4.5/11.3 1,084 2,413 2,508 3,142 820/547 */* */* */* 1.5/3.5 3.5/8.7 3.6/9.0 4.5/11.3 534 1,771 1,835 2,318 432/288 */1,553 */1,658 */* 1.5/3.5 3.2/8.0 3.3/8.2 4.2/10.4 259 1,370 1,442 1,802 254/169 */978 */1,048 */1,605 1.5/3.5 3.0/7.4 3.1/7.8 3.9/9.7 138 1,005 1,058 1,462 977/651 1,049/699 */1,089 */107 1.5/3.5 2.6/6.4 2.7/6.6 3.7/9.2 79 768 809 1,118 679/453 731/487 */769 */72 1.5/3.5 2.3/5.6 2.3/5.8 3.3/8.1 543 572 791 421/ 280 453/302 725/483 1.9/4.7 2.0/4.9 2.8/6.8 480 515 713 364/242 392/261 630/420 1.8/4.4 1.9/4.7 2.6/6.5 283 306 493 216/144 233/155 378/252 1.5/3.5 1.5/3.5 2.2/5.4 179 194 318 138/92 149/99 243/162 1.5/3.5 1.5/3.5 1.7/4.1 109 118 196 85/57 92/61 151/101 1.5/3.5 1.5/3.5 1.5/3.5 76 83 138 61/ 40 66/44 108/72 1.5/3.5 1.5/3.5 1.5/3.5 59 64 109 48/32 52/35 86/57 1.5/3.5 1.5/3.5 1.5/3.5 61 50/33 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 28 117⁄8" 4,192 */* 4.5/11.3 3,142 */* 4.5/11.3 2,507 */* 4.5/11.2 1,938 */1,831 4.2/10.4 1,579 */1,250 4.0/9.9 1,239 */886 3.6/8.9 877 840/560 3.0/7.5 791 731/487 2.8/7.1 547 440/293 2.4/5.9 373 284/189 1.9/4.7 230 177/118 1.5/3.5 163 127/84 1.5/3.5 128 101/67 1.5/3.5 72 59/39 1.5/3.5 14" 4,192 */* 4.5/11.3 3,142 */* 4.5/11.3 2,512 */* 4.5/11.3 2,092 */* 4.5/11.3 1,792 */* 4.5/11.3 1,567 */1,352 4.5/11.3 1,202 */870 4.1/10.3 1,084 */760 3.9/9.8 750 696/464 3.3/8.1 549 453/302 2.8/7.0 372 284/189 2.2/5.6 265 205/136 1.8/4.5 210 163/109 1.6/3.9 120 96/64 1.5/3.5 73 61/40 1.5/3.5 NON-SNOW ROOF LOAD TABLES General Notes ■ ■ Table is based on: –Uniform loads (beam weight considered). – More restrictive of simple or continuous span. –Deflection criteria of L/180 total load. For stiffer deflection criteria, use L/240 values for total load deflection. For door and window applications, Weyerhaeuser recommends using the L/360 value for a live load deflection limit and the L/240 value for a total load limit. Also see How to Use This Table on page 28 and General Assumptions on page 5. TimberStrand® LSL: Roof—Non-Snow Load Area 125% (PLF) continued Span 1.55E Grade Condition Total Load 3' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 4' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 5' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 6' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 7' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 8' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 9'-6" Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 10' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 12' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 14' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 16'-6" Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 18'-6" Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 20' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 24' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) Total Load 28' Deflection L/240 / L/360 Min. End/Int. Bearing (in.) 31 ⁄ 2 " 91 ⁄4" 91 ⁄ 2 " 7,564 7,918 */* */* 4.1/10.2 4.2/10.6 4,826 5,017 */* */* 3.5/8.7 3.6/9.0 3,542 3,670 */3,106 */3,316 3.2/8.0 3.3/8.2 2,741 2,884 */1,957 */2,097 3.0/7.4 3.1/7.8 2,011 2,116 1,954/1,302 2,098/1,399 2.6/6.4 2.7/6.6 1,537 1,618 1,359/906 1,462/974 2.3/5.6 2.3/5.8 1,087 1,144 842/561 907/605 1.9/4.7 2.0/4.9 961 1,031 728/485 785/523 1.8/4.4 1.9/4.7 566 612 432/288 467/311 1.5/3.5 1.5/3.5 359 388 276/184 299/199 1.5/3.5 1.5/3.5 218 236 171/114 185/123 1.5/3.5 1.5/3.5 152 166 122/81 132/88 1.5/3.5 1.5/3.5 119 129 97/64 105/70 1.5/3.5 1.5/3.5 65 71 56/37 61/40 1.5/3.5 1.5/3.5 111 ⁄4" 8,382 */* 4.5/11.3 6,282 */* 4.5/11.3 4,637 */* 4.2/10.4 3,604 */3,210 3.9/9.7 2,924 */2,179 3.7/9.2 2,236 */1,538 3.3/8.1 1,582 1,451/967 2.8/6.8 1,426 1,260/840 2.6/6.5 986 756/504 2.2/5.4 637 487/325 1.7/4.1 392 303/202 1.5/3.5 277 217/144 1.5/3.5 218 172/115 1.5/3.5 122 101/67 1.5/3.5 73 64/42 1.5/3.5 Width 117⁄8" 8,382 */* 4.5/11.3 6,282 */* 4.5/11.3 5,015 */* 4.5/11.2 3,876 */3,662 4.2/10.4 3,158 */2,501 4.0/9.9 2,479 */1,773 3.6/8.9 1,754 1,681/1,121 3.0/7.5 1,582 1,462/974 2.8/7.1 1,094 881/587 2.4/5.9 746 569/379 1.9/4.7 460 354/236 1.5/3.5 326 254/169 1.5/3.5 257 202/135 1.5/3.5 145 118/79 1.5/3.5 87 75/50 1.5/3.5 14" 8,382 */* 4.5/11.3 6,282 */* 4.5/11.3 5,022 */* 4.5/11.3 4,182 */* 4.5/11.3 3,582 */* 4.5/11.3 3,132 */2,705 4.5/11.3 2,404 */1,740 4.1/10.3 2,168 */1,520 3.9/9.8 1,501 1,393/928 3.3/8.1 1,098 907/605 2.8/7.0 744 569/379 2.2/5.6 531 410/273 1.8/4.5 421 327/218 1.6/3.9 241 192/128 1.5/3.5 147 122/81 1.5/3.5 16" 8,382 */* 4.5/11.3 6,282 */* 4.5/11.3 5,022 */* 4.5/11.3 4,182 */* 4.5/11.3 3,582 */* 4.5/11.3 3,132 */* 4.5/11.3 2,635 */2,456 4.5/11.3 2,502 */2,154 4.5/11.3 1,939 */1,334 4.2/10.5 1,420 1,316/877 3.6/9.0 1017 832/555 3.1/7.7 785 601/ 401 2.7/6.7 624 481/320 2.3/5.8 361 284/189 1.7/4.1 224 181/120 1.5/3.5 51 ⁄4" Width (2- or 3-ply) 91 ⁄4" 91 ⁄ 2 " 111 ⁄4" 117⁄8" 11,346 11,877 12,573 12,573 */* */* */* */* 4.1/10.2 4.2/10.6 4.5/11.3 4.5/11.3 7,239 7,526 9,423 9,423 */* */* */* */* 3.5/8.7 3.6/9.0 4.5/11.3 4.5/11.3 5,313 5,506 6,956 7,522 */4,659 */4,975 */* */* 3.2/8.0 3.3/8.2 4.2/10.4 4.5/11.2 4,111 4,326 5,406 5,814 */2,936 */3,146 */4,816 */5,493 3.0/7.4 3.1/7.8 3.9/9.7 4.2/10.4 3,016 3,174 4,386 4,737 2,931/1,954 3,148/2,098 */3,269 */3,752 2.6/6.4 2.7/6.6 3.7/9.2 4.0/9.9 2,306 2,427 3,354 3,719 2,038/1,359 2,193/1,462 */2307 */2,660 3.6/8.9 2.3/5.6 2.3/5.8 3.3/8.1 1,631 1,716 2,373 2,631 1,263/842 1,361/907 2,176/1,451 2,522/1,681 1.9/4.7 2.0/4.9 2.8/6.8 3.0/7.5 1,442 1,547 2,139 2,373 1,092/728 1,178/785 1,890/1,260 2,193/1,462 1.8/4.4 1.9/4.7 2.6/6.5 2.8/7.1 850 918 1,480 1,642 649/432 700/467 1,135/756 1,322/881 1.5/3.5 1.5/3.5 2.2/5.4 2.4/5.9 538 582 956 1,119 415/276 448/299 731/487 854/569 1.5/3.5 1.5/3.5 1.7/4.1 1.9/4.7 327 354 588 690 256/171 277/185 455/303 532/354 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 229 249 416 489 183/122 198/132 326/217 381/254 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 179 194 327 385 145/97 157/105 259/172 304/202 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 98 106 183 217 84/56 91/61 151/101 177/118 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 56 61 109 130 53/35 58/38 96/64 112/75 1.5/3.5 1.5/3.5 1.5/3.5 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 29 14" 16" 12,573 12,573 */* */* 4.5/11.3 4.5/11.3 9,423 9,423 */* */* 4.5/11.3 4.5/11.3 7,533 7,533 */* */* 4.5/11.3 4.5/11.3 6,273 6,273 */* */* 4.5/11.3 4.5/11.3 5,373 5,373 */* */* 4.5/11.3 4.5/11.3 4,698 4,698 */4,058 */* 4.5/11.3 4.5/11.3 3,606 3,952 */2,610 */3,684 4.1/10.3 4.5/11.3 3,253 3,753 */2,280 */3,232 3.9/9.8 4.5/11.3 2,252 2,908 2,089/1,393 */2,001 3.3/8.1 4.2/10.5 1,648 2,130 1,361/907 1,974/1,316 2.8/7.0 3.6/9.0 1,116 1,526 854/569 1,248/832 2.2/5.6 3.1/7.7 797 1,177 615/410 902/601 1.8/4.5 2.7/6.7 631 936 491/327 722/481 1.6/3.9 2.3/5.8 361 542 288/192 426/284 1.5/3.5 1.7/4.1 221 336 183/122 271/181 1.5/3.5 1.5/3.5 NON-SNOW ROOF LOAD TABLES How to Use This Table 1.Calculate total load (neglect beam weight) on the beam or header in pounds per linear foot (plf). 2.Select appropriate Span (center-to-center of bearing). 3.Scan horizontally to find the proper width, and a depth with a capacity that exceeds actual total load. 4.Review bearing length requirements to ensure adequacy. Also see General Notes on page 31. 1.9E Microllam® LVL: Roof—Non-Snow Load Area 125% (PLF) Span Condition Total Load 6' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 8' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 9'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 10' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 12' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 14' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 16'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 18'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 20' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 22' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 24' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 26' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 28' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 30' Deflection L/240 Min. End/Int. Bearing (in.) 51 ⁄ 2 " 451 435 1.5/3.5 146 * 1.5/3.5 73 * 1.5/3.5 59 * 1.5/3.5 71 ⁄4" 954 939 2.2/5.5 326 * 1.5/3.5 166 * 1.5/3.5 135 * 1.5/3.5 64 * 1.5/3.5 91 ⁄4" 1,285 * 2.9/7.4 870 833 2.7/6.7 616 516 2.2/5.6 555 446 2.1/5.3 348 265 1.6/4.0 221 169 1.5/3.5 135 104 1.5/3.5 95 74 1.5/3.5 74 59 1.5/3.5 55 44 1.5/3.5 13 ⁄4" Width 91 ⁄ 2 " 1,329 * 3.1/7.6 915 896 2.8/7.0 647 556 2.4/5.9 583 481 2.2/5.6 377 286 1.7/4.4 239 183 1.5/3.5 146 113 1.5/3.5 103 81 1.5/3.5 81 64 1.5/3.5 59 48 1.5/3.5 111 ⁄4" 1,656 * 3.8/9.5 1,145 * 3.5/8.8 888 * 3.2/8.1 801 772 3.1/7.7 554 463 2.6/6.4 392 298 2.1/5.3 242 185 1.6/3.9 171 133 1.5/3.5 135 106 1.5/3.5 101 80 1.5/3.5 76 61 1.5/3.5 59 48 1.5/3.5 117⁄8" 1,781 * 4.1/10.2 1,224 * 3.8/9.4 982 * 3.6/8.9 886 * 3.4/8.5 613 540 2.8/7.1 449 348 2.4/6.1 283 217 1.8/4.6 201 155 1.5/3.7 159 124 1.5/3.5 119 93 1.5/3.5 90 72 1.5/3.5 70 57 1.5/3.5 55 46 1.5/3.5 14" 1,961 * 4.5/11.3 1,469 * 4.5/11.3 1,212 * 4.4/11.0 1,137 * 4.4/10.9 835 * 3.9/9.6 611 556 3.3/8.3 438 349 2.8/7.0 328 251 2.4/5.9 260 200 2.0/5.1 195 152 1.7/4.2 150 117 1.5/3.6 117 93 1.5/3.5 92 74 1.5/3.5 74 61 1.5/3.5 51 ⁄ 2 " 902 870 1.5/3.5 292 * 1.5/3.5 146 * 1.5/3.5 118 * 1.5/3.5 54 * 1.5/3.5 71 ⁄4" 1,908 1,879 2.2/5.5 652 * 1.5/3.5 332 * 1.5/3.5 270 * 1.5/3.5 128 * 1.5/3.5 66 * 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 30 31 ⁄ 2" Width (2 ply) 91 ⁄4" 91 ⁄ 2 " 2,571 2,659 * * 2.9/7.4 3.1/7.6 1,741 1,830 1,666 1,792 2.7/6.7 2.8/7.0 1,232 1,294 1,032 1,112 2.2/5.6 2.4/5.9 1,110 1,167 893 963 2.1/5.3 2.2/5.6 697 753 530 572 1.6/4.0 1.7/4.4 443 479 339 366 1.5/3.5 1.5/3.5 270 292 209 227 1.5/3.5 1.5/3.5 190 206 149 162 1.5/3.5 1.5/3.5 149 162 119 128 1.5/3.5 1.5/3.5 110 119 89 97 1.5/3.5 1.5/3.5 83 90 69 75 1.5/3.5 1.5/3.5 63 69 54 59 1.5/3.5 1.5/3.5 53 47 1.5/3.5 111 ⁄4" 3,313 * 3.8/9.5 2,290 * 3.5/8.8 1,776 * 3.2/8.1 1,602 1,544 3.1/7.7 1,109 927 2.6/6.4 785 597 2.1/5.3 484 371 1.6/3.9 343 266 1.5/3.5 271 212 1.5/3.5 202 160 1.5/3.5 153 123 1.5/3.5 118 97 1.5/3.5 93 78 1.5/3.5 73 63 1.5/3.5 117⁄8" 3,563 * 4.1/10.2 2,449 * 3.8/9.4 1,965 * 3.6/8.9 1,772 * 3.4/8.5 1,227 1,080 2.8/7.1 898 697 2.4/6.1 567 435 1.8/4.6 403 311 1.5/3.7 319 248 1.5/3.5 238 187 1.5/3.5 181 145 1.5/3.5 140 114 1.5/3.5 110 92 1.5/3.5 88 75 1.5/3.5 NON-SNOW ROOF LOAD TABLES General Notes ■ Table is based on: –Uniform loads (beam weight considered). – More restrictive of simple or continuous span. –Deflection criteria of L/180 total load. For stiffer deflection criteria, use L/240 values for total load deflection. Also see How to Use This Table on page 30 and General Assumptions on page 5. 1.9E Microllam® LVL: Roof—Non-Snow Load Area 125% (PLF) continued Span Condition Total Load 6' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 8' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 9'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 10' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 12' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 14' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 16'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 18'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 20' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 22' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 24' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 26' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 28' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 30' Deflection L/240 Min. End/Int. Bearing (in.) 14" 3,917 * 4.5/11.3 2,932 * 4.5/11.3 2,425 * 4.4/11.0 2,275 * 4.4/10.9 1,670 * 3.9/9.6 1,223 1,112 3.3/8.3 876 698 2.8/7.0 656 502 2.4/5.9 520 401 2.0/5.1 391 304 1.7/4.2 300 235 1.5/3.6 234 186 1.5/3.5 185 149 1.5/3.5 148 122 1.5/3.5 31 ⁄ 2" Width (2-ply) 16" 18" 3,917 3,917 * * 4.5/11.3 4.5/11.3 2,932 2,932 * * 4.5/11.3 4.5/11.3 2,466 2,466 * * 4.5/11.3 4.5/11.3 2,342 2,342 * * 4.5/11.3 4.5/11.3 1,948 1,948 * * 4.5/11.3 4.5/11.3 1,571 1,667 * * 4.2/10.6 4.5/11.3 1,126 1,411 1,020 * 3.6/9.0 4.5/11.3 892 1,113 737 1,030 3.2/8.0 4.0/10.0 761 950 590 826 3.0/7.4 3.7/9.2 581 782 448 629 2.5/6.3 3.4/8.4 448 635 348 490 2.1/5.3 3.0/7.5 351 499 275 388 1.8/4.6 2.6/6.4 279 399 222 313 1.6/3.9 2.2/5.6 225 323 181 256 1.5/3.5 2.0/4.9 20" 51 ⁄ 2 " 3,917 1,353 1,305 * 4.5/11.3 1.5/3.5 2,932 438 * * 4.5/11.3 1.5/3.5 2,466 219 * * 4.5/11.3 1.5/3.5 2,342 177 * * 4.5/11.3 1.5/3.5 1,948 82 * * 4.5/11.3 1.5/3.5 1,667 * 4.5/11.3 1,411 * 4.5/11.3 1,256 * 4.5/11.3 1,158 1,112 4.5/11.2 954 850 4.1/10.2 798 663 3.7/9.4 677 527 3.5/8.6 547 425 3.0/7.6 444 348 2.7/6.6 71 ⁄4" 2,862 2,819 2.2/5.5 978 * 1.5/3.5 498 * 1.5/3.5 406 * 1.5/3.5 193 * 1.5/3.5 100 * 1.5/3.5 91 ⁄4" 3,857 * 2.9/7.4 2,611 2,499 2.7/6.7 1,847 1,548 2.2/5.6 1,666 1,339 2.1/5.3 1,046 795 1.6/4.0 664 509 1.5/3.5 405 314 1.5/3.5 285 224 1.5/3.5 224 178 1.5/3.5 165 134 1.5/3.5 124 104 1.5/3.5 95 82 1.5/3.5 73 65 1.5/3.5 57 53 1.5/3.5 91 ⁄ 2 " 3,989 * 3.1/7.6 2,745 2,688 2.8/7.0 1,942 1,669 2.4/5.9 1,751 1,444 2.2/5.6 1,130 859 1.7/4.4 719 550 1.5/3.5 439 340 1.5/3.5 309 243 1.5/3.5 243 193 1.5/3.5 179 145 1.5/3.5 135 112 1.5/3.5 103 88 1.5/3.5 80 71 1.5/3.5 62 58 1.5/3.5 51 ⁄4" Width (3-ply) 111 ⁄4" 117⁄8" 4,970 5,345 * * 3.8/9.5 4.1/10.2 3,435 3,673 * * 3.5/8.8 3.8/9.4 2,664 2,948 * * 3.2/8.1 3.6/8.9 2,403 2,659 2,317 * 3.1/7.7 3.4/8.5 1,663 1,840 1,391 1,620 2.6/6.4 2.8/7.1 1,178 1,347 896 1,046 2.1/5.3 2.4/6.1 726 851 557 652 1.6/3.9 1.8/4.6 515 605 399 467 1.5/3.5 1.5/3.7 406 478 318 372 1.5/3.5 1.5/3.5 303 357 240 281 1.5/3.5 1.5/3.5 230 272 185 218 1.5/3.5 1.5/3.5 178 211 146 172 1.5/3.5 1.5/3.5 139 166 117 138 1.5/3.5 1.5/3.5 110 132 95 112 1.5/3.5 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 31 14" 5,875 * 4.5/11.3 4,399 * 4.5/11.3 3,637 * 4.4/11.0 3,412 * 4.4/10.9 2,505 * 3.9/9.6 1,835 1,669 3.3/8.3 1,315 1,047 2.8/7.0 984 754 2.4/5.9 781 602 2.0/5.1 586 456 1.7/4.2 450 353 1.5/3.6 351 279 1.5/3.5 278 224 1.5/3.5 223 183 1.5/3.5 16" 5,875 * 4.5/11.3 4,399 * 4.5/11.3 3,699 * 4.5/11.3 3,513 * 4.5/11.2 2,922 * 4.5/11.2 2,356 * 4.2/10.6 1,689 1,530 3.6/9.0 1,339 1,106 3.2/8.0 1,142 885 3.0/7.4 872 672 2.5/6.3 672 522 2.1/5.3 527 413 1.8/4.6 419 333 1.6/3.9 338 271 1.5/3.5 18" 5,875 * 4.5/11.3 4,399 * 4.5/11.3 3,699 * 4.5/11.3 3,513 * 4.5/11.2 2,922 * 4.5/11.2 2,500 * 4.5/11.2 2,107 * 4.5/11.2 1,670 1,545 4.0/10.0 1,425 1,239 3.7/9.2 1,173 944 3.4/8.4 952 735 3.0/7.5 749 583 2.6/6.4 599 470 2.2/5.6 484 384 2.0/4.9 20" 5,875 * 4.5/11.3 4,399 * 4.5/11.3 3,699 * 4.5/11.3 3,513 * 4.5/11.2 2,922 * 4.5/11.2 2,500 * 4.5/11.2 2,117 * 4.5/11.2 1,884 * 4.5/11.2 1,737 1,669 4.5/11.2 1,431 1,275 4.1/10.2 1,197 995 3.7/9.4 1,015 790 3.5/8.6 820 638 3.0/7.6 666 522 2.7/6.6 NON-SNOW ROOF LOAD TABLES How to Use This Table 1.Calculate total load (neglect beam weight) on the beam or header in pounds per linear foot (plf). 2.Select appropriate Span (center-to-center of bearing). 3.Scan horizontally to find the proper width, and a depth with a capacity that exceeds actual total load. 4.Review bearing length requirements to ensure adequacy. Also see General Notes on page 33. 2.0E Parallam® PSL: Roof—Non-Snow Load Area 125% (PLF) Span Condition Total Load 8' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 9'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 10' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 12' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 14' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 16'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 18'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 20' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 22' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 24' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 26' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 28' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 30' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 32' Deflection L/240 Min. End/Int. Bearing (in.) 91 ⁄4" 1,839 1,753 2.8/7.0 1,365 1,086 2.5/6.2 1,231 940 2.4/5.9 734 558 1.7/4.3 466 357 1.5/3.5 284 220 1.5/3.5 200 157 1.5/3.5 157 125 1.5/3.5 115 94 1.5/3.5 87 73 1.5/3.5 66 57 1.5/3.5 51 46 1.5/3.5 91 ⁄ 2 " 1,899 1,886 2.9/7.3 1,436 1,171 2.6/6.5 1,295 1,013 2.5/6.2 793 602 1.8/4.6 504 386 1.5/3.5 308 238 1.5/3.5 217 170 1.5/3.5 170 135 1.5/3.5 126 102 1.5/3.5 95 79 1.5/3.5 72 62 1.5/3.5 56 50 1.5/3.5 111 ⁄4" 2,330 * 3.6/8.9 1,890 1,872 3.4/8.6 1,778 1,626 3.4/8.5 1,235 976 2.9/7.1 826 629 2.2/5.6 509 391 1.6/4.1 361 280 1.5/3.5 285 223 1.5/3.5 212 168 1.5/3.5 161 130 1.5/3.5 124 102 1.5/3.5 97 82 1.5/3.5 77 67 1.5/3.5 61 55 1.5/3.5 31 ⁄ 2" Width 117⁄ 8" 14" 2,491 2,933 * * 3.8/9.5 4.5/11.3 2,017 2,467 * * 3.7/9.2 4.5/11.3 1,896 2,314 1,886 * 3.6/9.1 4.4/11.1 1,369 1,854 1,137 1,797 3.2/7.9 4.3/10.7 966 1,370 734 1,171 2.6/6.5 3.7/9.2 597 965 457 735 1.9/4.8 3.1/7.7 424 690 328 529 1.5/3.9 2.5/6.2 335 548 422 261 1.5/3.5 2.1/5.4 250 411 197 320 1.5/3.5 1.8/4.5 191 315 153 248 1.5/3.5 1.5/3.8 148 246 120 196 1.5/3.5 1.5/3.5 116 195 97 157 1.5/3.5 1.5/3.5 92 156 79 128 1.5/3.5 1.5/3.5 74 126 65 106 1.5/3.5 1.5/3.5 16" 2,933 * 4.5/11.3 2,467 * 4.5/11.3 2,342 * 4.5/11.3 1,949 * 4.5/11.3 1,667 * 4.5/11.3 1,266 1,074 4.0/10.1 1,003 776 3.6/9.0 810 621 3.2/7.9 611 472 2.6/6.6 471 366 2.2/5.6 369 290 1.9/4.8 294 233 1.7/4.2 236 190 1.5/3.6 192 157 1.5/3.5 18" 2,933 * 4.5/11.3 2,467 * 4.5/11.3 2,342 * 4.5/11.3 1,949 * 4.5/11.3 1,667 * 4.5/11.3 1,412 * 4.5/11.3 1,256 1,084 4.5/11.3 1,071 869 4.2/10.4 863 662 3.7/9.3 668 515 3.1/7.9 525 409 2.7/6.8 420 329 2.3/5.9 339 269 2.1/5.1 277 223 1.8/4.5 91 ⁄4" 2,759 2,630 2.8/7.0 2,048 1,630 2.5/6.2 1,847 1,410 2.4/5.9 1,101 837 1.7/4.3 699 535 1.5/3.5 426 331 1.5/3.5 300 236 1.5/3.5 235 188 1.5/3.5 173 141 1.5/3.5 130 109 1.5/3.5 100 86 1.5/3.5 77 69 1.5/3.5 60 56 1.5/3.5 91 ⁄ 2 " 2,848 2,830 2.9/7.3 2,154 1,757 2.6/6.5 1,942 1,520 2.5/6.2 1,190 904 1.8/4.6 756 579 1.5/3.5 462 358 1.5/3.5 325 256 1.5/3.5 255 203 1.5/3.5 189 153 1.5/3.5 142 118 1.5/3.5 109 93 1.5/3.5 84 75 1.5/3.5 65 61 1.5/3.5 51 50 1.5/3.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 32 111 ⁄4" 3,494 * 3.6/8.9 2,836 2,808 3.4/8.6 2,668 2,439 3.4/8.5 1,853 1,464 2.9/7.1 1,240 943 2.2/5.6 764 587 1.6/4.1 542 420 1.5/3.5 427 334 1.5/3.5 318 252 1.5/3.5 242 195 1.5/3.5 187 154 1.5/3.5 146 123 1.5/3.5 116 101 1.5/3.5 92 83 1.5/3.5 51 ⁄4" Width 117⁄ 8" 3,737 * 3.8/9.5 3,025 * 3.7/9.2 2,844 2,830 3.6/9.1 2,053 1,706 3.2/7.9 1,449 1,102 2.6/6.5 896 686 1.9/4.8 637 492 1.5/3.9 503 392 1.5/3.5 375 296 1.5/3.5 286 229 1.5/3.5 222 181 1.5/3.5 174 145 1.5/3.5 138 118 1.5/3.5 111 97 1.5/3.5 14" 4,400 * 4.5/11.3 3,700 * 4.5/11.3 3,471 * 4.4/11.1 2,781 2,696 4.3/10.7 2,055 1,757 3.7/9.2 1,447 1,103 3.1/7.7 1,035 794 2.5/6.2 822 633 2.1/5.4 617 480 1.8/4.5 473 372 1.5/3.8 369 294 1.5/3.5 292 236 1.5/3.5 234 193 1.5/3.5 189 159 1.5/3.5 16" 4,400 * 4.5/11.3 3,700 * 4.5/11.3 3,514 * 4.5/11.3 2,923 * 4.5/11.3 2,501 * 4.5/11.3 1,899 1,611 4.0/10.1 1,505 1,164 3.6/9.0 1,216 931 3.2/7.9 917 708 2.6/6.6 707 550 2.2/5.6 554 435 1.9/4.8 441 350 1.7/4.2 355 286 1.5/3.6 289 236 1.5/3.5 18" 4,400 * 4.5/11.3 3,700 * 4.5/11.3 3,514 * 4.5/11.3 2,923 * 4.5/11.3 2,501 * 4.5/11.3 2,118 * 4.5/11.3 1,884 1,626 4.5/11.3 1,607 1,304 4.2/10.4 1,295 994 3.7/9.3 1,002 773 3.1/7.9 788 613 2.7/6.8 630 494 2.3/5.9 509 404 2.1/5.1 416 334 1.8/4.5 NON-SNOW ROOF LOAD TABLES General Notes ■ Table is based on: –Uniform loads (beam weight considered). – More restrictive of simple or continuous span. –Deflection criteria of L/180 total load. For stiffer deflection criteria, use L/240 values for total load deflection. Also see How to Use This Table on page 32 and General Assumptions on page 5. 2.0E Parallam® PSL: Roof—Non-Snow Load Area 125% (PLF) continued Span Condition Total Load 8' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 9'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 10' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 12' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 14' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 16'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 18'-6" Deflection L/240 Min. End/Int. Bearing (in.) Total Load 20' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 22' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 24' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 26' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 28' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 30' Deflection L/240 Min. End/Int. Bearing (in.) Total Load 32' Deflection L/240 Min. End/Int. Bearing (in.) 91 ⁄4" 3,679 3,507 2.8/7.0 2,731 2,173 2.5/6.2 2,462 1,880 2.4/5.9 1,468 1,116 1.7/4.3 932 714 1.5/3.5 569 441 1.5/3.5 400 315 1.5/3.5 314 250 1.5/3.5 231 189 1.5/3.5 174 146 1.5/3.5 133 115 1.5/3.5 102 92 1.5/3.5 80 75 1.5/3.5 62 62 1.5/3.5 91 ⁄ 2 " 3,798 3,773 2.9/7.3 2,872 2,342 2.6/6.5 2,590 2,027 2.5/6.2 1,586 1,205 1.8/4.6 1,008 772 1.5/3.5 616 477 1.5/3.5 434 341 1.5/3.5 340 271 1.5/3.5 252 204 1.5/3.5 190 158 1.5/3.5 145 124 1.5/3.5 112 100 1.5/3.5 87 81 1.5/3.5 68 67 1.5/3.5 111 ⁄4" 4,660 * 3.6/8.9 3,781 3,745 3.4/8.6 3,557 3,252 3.4/8.5 2,471 1,953 2.9/7.1 1,653 1,258 2.2/5.6 1,019 782 1.6/4.1 723 560 1.5/3.5 570 446 1.5/3.5 425 337 1.5/3.5 323 260 1.5/3.5 249 205 1.5/3.5 195 165 1.5/3.5 154 134 1.5/3.5 123 111 1.5/3.5 7" Width 117⁄ 8" 4,983 * 3.8/9.5 4,034 * 3.7/9.2 3,792 3,773 3.6/9.1 2,738 2,274 3.2/7.9 1,933 1,469 2.6/6.5 1,195 915 1.9/4.8 849 656 1.5/3.9 671 523 1.5/3.5 501 395 1.5/3.5 382 306 1.5/3.5 296 241 1.5/3.5 232 194 1.5/3.5 184 158 1.5/3.5 148 130 1.5/3.5 14" 5,866 * 4.5/11.3 4,934 * 4.5/11.3 4,628 * 4.4/11.1 3,708 3,595 4.3/10.7 2,741 2,342 3.7/9.2 1,930 1,470 3.1/7.7 1,381 1,058 2.5/6.2 1,096 845 2.1/5.4 823 640 1.8/4.5 631 496 1.5/3.8 492 392 1.5/3.5 390 315 1.5/3.5 312 257 1.5/3.5 253 212 1.5/3.5 16" 5,866 * 4.5/11.3 4,934 * 4.5/11.3 4,685 * 4.5/11.3 3,898 * 4.5/11.3 3,335 * 4.5/11.3 2,532 2,148 4.0/10.1 2,007 1,553 3.6/9.0 1,621 1,242 3.2/7.9 1,223 944 2.6/6.6 942 733 2.2/5.6 739 580 1.9/4.8 588 467 1.7/4.2 473 381 1.5/3.6 385 315 1.5/3.5 18" 5,866 * 4.5/11.3 4,934 * 4.5/11.3 4,685 * 4.5/11.3 3,898 * 4.5/11.3 3,335 * 4.5/11.3 2,824 * 4.5/11.3 2,512 2,168 4.5/11.3 2,143 1,739 4.2/10.4 1,727 1,325 3.7/9.3 1,336 1,031 3.1/7.9 1,051 818 2.7/6.8 840 659 2.3/5.9 679 539 2.1/5.1 555 446 1.8/4.5 * Indicates Total Load value controls. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 33 BEAM DETAILS Bearing at Wall Beam to Beam Connection Bearing for Door or Window Header 1¼" TimberStrand® LSL or 11⁄8" TJ® rim board or blocking for lateral support Strap per code if top plate is not continuous over header Top mount hanger L1 Column L2 Bearing at Concrete Wall L3 Bearing at Column Face mount hanger See Framing Connectors on pages 40 and 41 Beam to Column Lateral Brace TJI® joist Floor beam Strap Steel column L4 Protect untreated wood from direct contact with concrete L5 Verify beam bearing length on page 36 and column capacity on page 42 L14 Suggested lateral bracing detail for beams when required. Verify beam bearing length on page 36. WINDOW AND DOOR HEADER DETAILS 2x4 Wall Framing High Header Low Header Full Depth Header Header Header Header L8 L7 L9 2x_ nailer* *Double nailer may be required depending upon the opening size and window type 2x6 Wall Framing Headers not matching wall thickness may be installed flush to the inside or outside of the wall, depending upon sheathing and trim attachment requirements Plank Orientation Header Low Header High Header Double top plate 2x6 wall framing L10 31⁄2" x 51⁄2" TimberStrand® LSL in plank orientation 31⁄2"-wide header L11 31⁄2"-wide header 2x_ framing at opening L12 *Double nailer may be required depending upon the opening size and window type Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 34 2x_ nailer* Window and Door Header Details Dropped Header with Full Lateral Bracing Framing above must be sheathed to provide lateral stability to the top of the beam Main structural header. See pages 38 and 39 for connecting multiple plies. One 8d (0.113" x 21/2") nail each side of joist or blocking. Blocking is required if joist framing is parallel to beam. Joist spacing must be 24" on-center or less. Low header Nail continuous king studs to the end of the beam using: – F our 10d (0.131" x 3") nails for beams 117⁄8" deep or less – S ix 10d (0.131" x 3") nails for beams 18" deep or less – E ight 10d (0.131" x 3") nails for beams greater than 18" deep L15 Fasten 2x_ plate to low header with 10d (0.131" x 3") nails at 8" on-center, staggered Continuous king stud Dropped Header with Acceptable Lateral Bracing 4'-0" maximum height cripple wall. Wall studs at 24" on-center, maximum. One 8d (0.113" x 2½") nail each side of joist or blocking. Blocking is required if joist framing is parallel to beam. Joist spacing must be 24" on-center or less. Fasten 2x_ plate to header below with 10d (0.131" x 3") nails at 8" on-center, staggered Sheathing strength axis See pages 38 and 39 for connecting multiple plies Nail continuous king studs to the end of the beam using: – F our 10d (0.131" x 3") nails for beams 117⁄8" deep or less – Six 10d (0.131" x 3") nails for beams 16" deep or less L16 Rated wall sheathing (7⁄16" nominal) continuous from bottom of beam to top of wall. Fasten sheathing with 8d (0.113" x 21/2") nails at 6" on-center at panel edges and 12" on-center in panel field. Continuous king stud When framed as shown above, the following dropped headers are considered fully braced under uniform-load, simple-span conditions: Single-ply: – 1¾" wide headers, 117⁄8" deep or less – 3½" wide headers, 16" deep or less, with a maximum span of 18'-6" Multiple-ply: – Headers up to four 1¾" plies, 117⁄8" deep or less – Headers up to four 1¾" x 14" plies, with a maximum span of 8'-6" NAILING ON NARROW FACE Nails Installed on the Narrow Face Nail Size 8d (0.131" x 2½") or 10d (0.128" x 3") 10d (0.148" x 3") or 12d (0.148" x 3¼") 16d (0.162" x 3½") ■ Closest On-Center Spacing Per Row 3½" 1¾" Microllam ® LVL TimberStrand ® LSL TimberStrand ® LSL Parallam ® PSL 3" 3" 3" 3" 4" 3" 4" 4" 6" 3½" 8" 6" If more than one row of nails is used, the rows must be offset at least ½" and staggered. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 35 ALLOWABLE HOLES 1.55E TimberStrand® LSL Headers and Beams General Notes 2 x diameter of the largest hole (minimum) 1⁄ 3 ■ Allowed hole zone depth Allowed hole zone suitable for headers and beams with uniform and/or concentrated loads anywhere along the member. ■ Round holes only. ■ No holes in headers or beams in plank orientation. 1.55E TimberStrand® LSL 8" Header or Beam Depth 9¼"–9½" 11¼"–117⁄ 8" 14"–16" 8" ■ ■ 2 x diameter of the largest hole (minimum) 1⁄ 3 d 1.3E TimberStrand® LSL allowed hole zone depth Allowed hole zone suitable for headers and beams with uniform loads only. ■ Round holes only. ■ No holes in cantilevers. ■ No holes in headers or beams in plank orientation. Other Trus Joist® Beams Microllam® LVL and Parallam® PSL allowed hole zone middle 1⁄3 span d See illustration for allowed hole zone. General Notes Other Trus Joist® Headers and Beams Microllam® LVL and 1.3E TimberStrand® LSL Parallam® PSL hole zone hole zone Maximum Round Hole Size 3" 35 ⁄ 8 " 45 ⁄ 8" Header or Beam Depth 4 3⁄ 8" 5½" 7¼"–20" d ■ DO NOT cut, notch, or drill holes in headers or beams except as indicated in the illustrations and tables Maximum Round Hole Size 1" 1¾" 2" See illustration for allowed hole zone. WARNING: Drilling, sawing, sanding or machining wood products generates wood dust, a substance known to the State of California to cause cancer. For more information on Proposition 65, visit www.wy.com/inform. BEARING LENGTH REQUIREMENTS Reaction (lbs) 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 22,000 24,000 26,000 28,000 30,000 1.3E TimberStrand ® LSL Beam Orientation Plank Orientation Width Width 3½" 5½" 11 ⁄ 2" 11 ⁄ 2" 13 ⁄4" 13 ⁄4" 23 ⁄4" 23 ⁄4" 31 ⁄ 2" 31 ⁄ 2" 41 ⁄4" 41 ⁄4" 51 ⁄4" 51 ⁄4" 6" 6" 63 ⁄4" 63 ⁄4" 73 ⁄4" 73 ⁄4" 1.55E TimberStrand ® LSL Beam Orientation Width 1¾" 3½" 5¼" 11/2" 11/2" 11/2" 3" 11/2" 11/2" 41/2" 21/4" 11/2" 53/4" 3" 2" 71/4" 33/4" 21/2" 41/2" 3" 5" 31/2" 53/4" 4" 61/2" 41/2" 71/4" 5" 8" 51/4" 53/4" 61/4" 63/4" 71/4" 1.9E Microllam ® LVL Beam Orientation Width 1¾" 3½" 5¼" 13 ⁄4" 11 ⁄ 2" 11 ⁄ 2" 31 ⁄4" 13 ⁄4" 11 ⁄ 2" 43 ⁄4" 21 ⁄ 2" 13 ⁄4" 61 ⁄4" 31 ⁄4" 21 ⁄4" 73 ⁄4" 4" 23 ⁄4" 43 ⁄4" 31 ⁄4" 51 ⁄ 2" 33 ⁄4" 61 ⁄4" 41 ⁄4" 7" 43 ⁄4" 73 ⁄4" 51 ⁄4" 53 ⁄4" 61 ⁄4" 63 ⁄4" 71 ⁄4" 73 ⁄4" 2.0E Parallam ® PSL Beam Orientation Width 3½" 5¼" 7" 11 ⁄ 2" 11 ⁄ 2" 11 ⁄ 2" 13 ⁄4" 11 ⁄ 2" 11 ⁄ 2" 21 ⁄ 2" 13 ⁄4" 11 ⁄ 2" 31 ⁄4" 21 ⁄4" 13 ⁄4" 4" 23 ⁄4" 2" 43 ⁄4" 31 ⁄4" 21 ⁄ 2" 51 ⁄ 2" 33 ⁄4" 23 ⁄4" 61 ⁄4" 41 ⁄4" 31 ⁄4" 7" 43 ⁄4" 31 ⁄ 2" 73 ⁄4" 51 ⁄4" 4" 53 ⁄4" 41 ⁄4" 61 ⁄4" 43 ⁄4" 63 ⁄4" 5" 71⁄4" 51 ⁄ 2" 73 ⁄4" 53 ⁄4" General Notes ■ Minimum bearing length: 11⁄2" at ends, 31⁄2" at intermediate supports. ■ Bearing across full beam width required. ■ Interpolation between reaction loads is permitted for determining bearing lengths. ■ Bearing lengths based on the following bearing stresses: – 1.3E TimberStrand ® LSL: 680 psi; 435 psi for plank orientation. – 1.55E TimberStrand ® LSL: 800 psi. – 1.9E Microllam ® LVL: 750 psi. –2.0E Parallam ® PSL: 750 psi. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 36 Tapered End Cuts Allowable Reactions for 31⁄2"(1) TimberStrand® LSL Headers and Beams (lbs) Bearing 31⁄2" Wood Plate (2) 51⁄4" Wood Plate (2) 31⁄2" Column(3) Beam Depth 71/4"–91/4" 91/2" 111/4" 117⁄ 8" 14" 16" 71/4" 85 ⁄ 8" 91/4" 91/2" 111/4" 117⁄ 8"–14" 16" 71/4" 85 ⁄ 8" 91/4" 91/2" 111/4" 117⁄ 8" 14" 16" 41⁄2" 4,860 4,860 4,860 4,860 5" 5,205 5,205 5,205 5,205 5,205 51⁄2" 5,205 5,205 5,205 5,205 5,205 6,765 6,780 5,255 5,255 5,255 5,255 6,765 7,365 5,710 5,710 5,710 5,710 6,270 6,270 4,860 4,860 4,860 4,860 6,765 6,855 5,310 5,310 5,310 5,310 5,310 6,765 7,810 6,160 6,160 6,160 6,160 6,160 6,765 7,435 5,765 5,765 5,765 5,765 5,765 Outside Heel Height D1 6" 61⁄2" 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 7,810 6,610 6,610 6,610 6,610 6,610 6,765 8,020 6,215 6,215 6,215 6,215 6,215 6,215 7" 5,205 5,205 5,205 5,205 5,205 5,205 71⁄2" 5,205 5,205 5,205 5,205 5,205 5,205 8" 5,205 5,205 5,205 5,205 5,205 5,205 7,810 6,690 6,870 7,065 7,065 7,065 7,810 6,690 6,870 7,515 7,515 7,515 7,810 6,690 6,870 7,810 7,810 7,810 6,870 7,810 7,810 7,810 8,050 6,670 6,670 6,670 6,670 6,670 6,670 8,050 6,690 6,870 7,120 7,120 7,120 7,120 8,050 6,690 6,870 7,570 7,570 7,570 7,570 6,690 6,870 8,025 8,025 8,025 8,025 General Notes No increase for duration of load is permitted. ■ ■ ■ No holes or concentrated load within tapered cut. Table considers only downward loading. Contact your Weyerhaeuser representative for assistance with uplift loading or other conditions. Minimum 3:12 slope Sloped end cut D1 (1) For 13⁄4" and 51⁄4" beams, multiply by 0.5 and 1.5, respectively. (2) Bearing lengths, based on Fc⊥ of 425 psi. (3) Bearing lengths based on Fc⊥ of 680 psi for 1.3E TimberStrand® LSL and 800 psi for 1.55E TimberStrand® LSL. Tapered end cut detailed above is not allowed with TJI® joists Allowable Reactions for 31⁄2"(1) Microllam® LVL and Parallam® PSL Beams (lbs) Bearing 31 ⁄ 2 " Wood Plate (2) 51⁄4" Wood Plate (2) 31 ⁄ 2 " Column(3) Beam Depth 71⁄4" 91⁄4" 91 ⁄ 2 " 111⁄4" 117⁄ 8" 14" 16" 18" 20" 71⁄4" 91⁄4" 91 ⁄ 2 " 111⁄4" 117⁄ 8" 14" 16" 18" 20" 71⁄4" 91⁄4" 91 ⁄ 2 " 111⁄4" 117⁄ 8" 14" 16" 18" 20" 41 ⁄ 2" 4,470 4,470 4,470 4,470 4,470 5" 4,820 4,885 4,885 4,885 4,885 4,885 51 ⁄ 2 " 4,820 5,205 5,205 5,205 5,205 5,205 4,820 4,830 4,830 4,830 4,830 4,830 4,820 5,245 5,245 5,245 5,245 5,245 4,820 5,665 5,665 5,665 5,665 5,665 5,665 4,470 4,470 4,470 4,470 4,470 4,820 4,885 4,885 4,885 4,885 4,885 4,820 5,300 5,300 5,300 5,300 5,300 Outside Heel Height D1 6" 61 ⁄ 2 " 7" 4,820 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 6,080 6,080 6,080 6,080 6,080 6,080 6,080 4,820 5,715 5,715 5,715 5,715 5,715 5,715 Beam depth Wood Plate Connection 71 ⁄ 2 " 8" 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 5,205 10" Sloped end cut Beam depth D1 5,205 5,205 5,205 5,205 5,205 5,205 6,150 6,320 6,495 6,495 6,495 6,495 6,495 6,150 6,320 6,910 6,910 6,910 6,910 6,910 6,910 6,150 6,320 7,325 7,325 7,325 7,325 7,325 7,325 6,320 7,480 7,740 7,740 7,740 7,740 7,740 7,810 7,810 7,810 7,810 7,810 6,130 6,130 6,130 6,130 6,130 6,130 6,130 6,150 6,320 6,545 6,545 6,545 6,545 6,545 6,150 6,320 6,960 6,960 6,960 6,960 6,960 6,960 6,150 6,320 7,375 7,375 7,375 7,375 7,375 7,375 7,480 7,895 9,040 9,040 9,040 9,040 Wood plate Column Connection Sloped end cut (1) For 13⁄4", 51⁄4", and 7" beams, multiply by 0.5, 1.5, and 2.0, respectively. (2) Bearing lengths based on Fc⊥ of 425 psi. (3) Bearing lengths based on Fc⊥ of 750 psi. Beam depth D1 Column DO NOT overhang seat cuts on beams beyond inside face of support member Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 37 MULTIPLE-MEMBER CONNECTIONS FOR SIDE-LOADED BEAMS L17 Uniform Load—Maximum Uniform Load Applied to Either Outside Member (PLF) Assembly A Fastener Type Number of Rows Fastener On-Center Spacing 2 3 ½" A307 Through Bolts (2)(3) 2 SDS ¼" x 3½" (3) 2 SDS ¼" x 6" (3) 2 USP WS35 (3) 2 USP WS6 (3) 2 33 ⁄ 8" TrussLOK®(3) 2 5" TrussLOK®(3) 2 6¾" TrussLOK®(3) 2 33 ⁄ 8" SDW22(3) 2 5" SDW22 (3) 2 6 3 ⁄4" SDW22 (3) 2 12" 12" 24" 19.2" 16" 24" 19.2" 16" 24" 19.2" 16" 24" 19.2" 16" 24" 19.2" 16" 24" 19.2" 16" 24" 19.2" 16" 24" 19.2" 16" 24" 19.2" 16" 24" 19.2" 16" 24" 19.2" 16" Assembly C Fastener Pattern Assembly D Assembly E 2" 2" 2" 2" 13⁄4" 10d (0.128" x 3") Nail(1) Assembly B 13⁄4" 13⁄4" 31⁄2" 3½" wide, 2-ply 5¼" wide, 3-ply 5¼" wide, 2-ply 370 280 280 555 415 415 505 380 520 635 475 655 760 570 785 680 510 510 850 640 640 1,020 765 765 480 600 715 535 670 800 800 1,000 1,200 360 450 540 360 450 540 400 500 600 435 545 655 400 500 600 435 545 655 600 750 900 450 565 675 600 750 900 450 565 675 (1) Nailed connection values may be doubled for 6" on-center or tripled for 4" on-center nail spacing. (2) Washers required. Bolt holes to be 9⁄16" maximum. (3) 2 4" on-center bolted and screwed connection values may be doubled for 12" on-center spacing. 2" 2" 13⁄4" 31⁄2" 13⁄4" 7" wide, 3-ply 245 370 465 580 695 455 565 680 455 565 680 320 400 480 350 440 525 355 445 535 385 485 580 385 485 580 535 665 800 535 665 800 400 500 600 31⁄2" 7" wide, 2-ply 7" wide, 4-ply 860 1,075 1,290 340 425 505 465 580 695 455 565 680 525 660 790 350 440 525 580 725 870 385 485 580 800 1,000 1,200 400 500 600 300 PLF Connections are based on NDS® 2005 or manufacturer’s test or code reports. Use specific gravity of 0.5 when designing lateral connections. Values listed are for 100% stress level. Increase 15% for snow-loaded roof conditions or 25% for non-snow roof conditions, where code allows. Bold Italic cells indicate Fastener Pattern must be installed on both sides. Stagger fasteners on the second side so they fall halfway between fasteners on the first side. Verify adequacy of beam in allowable load tables on pages 16–33. 7" wide beams should be side-loaded only when loads are applied to both sides of the members (to minimize rotation). Minimum end distance for bolts and screws is 6". Beams wider than 7" require special consideration by the design professional of record. ■ ■ ■ ■ ■ ■ ■ 13⁄4" Uniform Load Design Example General Notes ■ Assembly F 415 PLF First, check the allowable load tables on pages 16–33 to verify that three pieces can carry the total load of 715 plf with proper live load deflection criteria. Maximum load applied to either outside member is 415 plf. For a 3-ply, 13⁄4" assembly, two rows of 10d (0.128" x 3") nails at 12" on-center is good for only 280 plf. Therefore, use three rows of 10d (0.128" x 3") nails at 12" on-center (good for 415 plf). Alternative: Two rows of 1⁄2" bolts or 1⁄4" x 31⁄2" SDS screws at 19.2" on-center. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 38 MULTIPLE-MEMBER CONNECTIONS FOR SIDE-LOADED BEAMS L18 Point Load—Maximum Point Load Applied to Either Outside Member (lbs) Assembly A Fastener Pattern Assembly C Assembly D Assembly B Assembly E 2" 2" 2" 2" Assembly F 2" Number of Fasteners Fastener Type 13⁄4" 3½" wide, 2-ply 1,110 2,225 3,335 4,450 1,915 2,870 3,825 2,135 3,205 4,270 3,200 4,800 6,400 6 12 18 24 4 6 8 4 6 8 4 6 8 10d (0.128" x 3") Nail ¼" x 3½" or ¼" x 6" SDS, USP WS35, or USP WS6 33 ⁄ 8", 5", or 6¾" TrussLOK® 33 ⁄ 8", 5", or 6¾" SDW22 13⁄4" 5¼" wide, 3-ply 835 1,670 2,505 3,335 1,435 2,155 2,870 1,600(1) 2,405(1) 3,205(1) 1,800(1) 2,700(1) 3,600(1) (1) 5" long screws screws may be installed from one side only. (2) 6¾" long screws screws may be installed from one side only. 13⁄4" 31⁄2" 13⁄4" 31⁄2" 13⁄4" 31⁄2" 5¼" wide, 2-ply 835 1,670 2,505 3,335 1,435 2,155 2,870 1,600 2,405 3,205 1,800 2,700 3,600 7" wide, 3-ply 740 1,485 2,225 2,965 1,275 1,915 2,550 1,425(2) 2,135(2) 2,850(2) 1,600(2) 2,400(2) 3,200(2) 7" wide, 2-ply 7" wide, 4-ply 1,860(3) 2,785(3) 3,715(3) 2,320(4) 3,480(4) 4,640(4) 3,200(4) 4,800(4) 6,400(4) 1,405(3) 2,110(3) 2,810(3) 1,425(4) 2,135(4) 2,850(4) 1,600(4) 2,400(4) 3,200(4) SDS or TrussLOK® screw, typical Point Load Design Example 8-Screw Connection Nail Connection 2" at top and bottom, typical 3,000 lbs 10d (0.128" x 3") nails, typical. Stagger to prevent splitting. SDS or TrussLOK® screw, typical 2" spacing, typical 14" 2" ½ beam depth L19 13⁄4" Bold italic cells indicate that fastener pattern must be installed from both sides. See General Notes on page 38. (3) 6" long screw required. (4) 6¾" long screw required. Point Load Connector Spacing 4- or 6-Screw Connection 2" 2" Equal spacing 2" 8"–10" 2" 11/2" minimum spacing, typical L21 There must be an equal number of nails on each side of the connection L20 First, verify that a 3-ply, 1¾" x 14" beam can support a 3,000 lb point load and all other loads applied. The 3,000 lb point load is being trans ferred to the beam with a face mount hanger. For a 3-ply, 1¾" assembly, eight 33⁄8" TrussLOK® screws are good for 3,205 lbs with a face mount hanger. Multiple-Member Connections for Top-Loaded Beams Connector Installation Requirements Piece Width # of Plies 2 1¾" 3 Type (1) 10d nails 12d–16d nails Screws 10d nails 12d–16d nails Screws 4 3½" 2 Screws Screws ½" bolts Min. Length 3" 3¼" 33∕8" or 3½" 3" 3¼" 33∕8" or 3½" 5" 5" or 6" 6¾" 5" or 6" 6¾" 8" Fastener # Rows 3(2) 2(2) 2 3(2) 2(2) O.C. Spacing 12" One side 24" 12" 2 24" 2 24" 2 24" 2 Location Both sides Both sides One side Both sides One side Both sides One side – 24" Load must be applied evenly across entire beam width. Otherwise, use connections for side-loaded beams L6 Multiple pieces can be nailed or bolted together to form a header or beam of the required size, up to a maximum width of 7" (1)10d nails are 0.128" diameter; 12d–16d nails are 0.148"–0.162" diameter; screws are SDS, SDW, WS, or TrussLOK™. (2)An additional row of nails is required with depths of 14" or greater. When fasteners are required on both sides, stagger fasteners on the second side so they fall halfway between fasteners on the first side. ■ Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 39 FRAMING CONNECTORS Top Mount Hangers—Simpson Strong-Tie® Supported Member Width Supported Member Depth 91 ⁄4" 9½" 13 ⁄4" 111 ⁄4" 117⁄ 8" 3½" 5¼" 7" 14" 9¼" 9½" 111 ⁄4" 117⁄ 8" 14" 16" 18" 20" 91 ⁄4" 91 ⁄ 2 " 111 ⁄4" 117⁄ 8" 14" 16" 18" 20" 117⁄ 8" 14" 16" 18" Hanger WPU1.81/9.25 LBV1.81/9.25 MIT9.5 LBV1.81/9.5 WPU1.81/11.25 LBV1.81/11.25 MIT11.88 BA1.81/11.88 B1.81/14 HB3.56/9.25 HB3.56/9.5 HB3.56/11.25 HB3.56/11.88 GLTV3.514 GLTV3.516 HGLTV3.518 HGLTV3.520 GLTV5.50/9.25 GLTV5.59 GLTV5.50/11.25 HGLTV5.511 EGQ5.50-SDS3 EGQ5.50-SDS3 EGQ5.50-SDS3 EGQ5.50-SDS3 EGQ7.25-SDS3 EGQ7.25-SDS3 EGQ7.25-SDS3 EGQ7.25-SDS3 Nail Type Header 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d SDS 1/4" x 3" SDS 1/4" x 3" SDS 1/4" x 3" SDS 1/4" x 3" SDS 1/4" x 3" SDS 1/4" x 3" SDS 1/4" x 3" SDS 1/4" x 3" Joist 10d x 11/2" 10d x 11/2" 10d x 11/2" 10d x 11/2" 10d x 11/2" 10d x 11/2" 10d x 11/2" 10d x 11/2" 10d x 11/2" 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d SDS 1/4" x 3" SDS 1/4" x 3" SDS 1/4" x 3" SDS 1/4" x 3" SDS 1/4" x 3" SDS 1/4" x 3" SDS 1/4" x 3" SDS 1/4" x 3" Allowable Load (lbs)—100% (1) Support Member Material LSL, LVL, PSL DF/SP SPF 4,165 4,165 3,650 2,885 2,590 2,060 2,305 1,665 2,115 2,885 2,590 2,060 3,650 4,165 4,165 2,885 2,590 2,060 2,115 2,305 1,665 3,435 2,665 3,705 3,640 2,650 3,355 5,640 5,650 3,820 5,640 5,650 3,820 5,640 5,650 3,820 5,640 5,650 3,820 5,750 7,000 5,145 5,750 7,000 5,145 9,000 8,665 6,770 9,000 8,665 6,770 5,750 7,000 5,145 5,750 7,000 5,145 5,750 7,000 5,145 9,000 8,665 6,770 18,680 – – 18,680 – – 18,680 – – 18,680 – – 18,680 – – 18,680 – – 18,680 – – 18,680 – – (1) Maximum load for top mount hangers may not be increased for duration of load. Face Mount Hangers—Simpson Strong-Tie® Supported Member Width Supported Member Depth 7¼"–9½" 13 ⁄4" 11¼"–14" 7¼"–11¼" 3½" 5¼" 9½"–18" 14"–20" 9¼"–117⁄ 8" 11¼"–14" 14"–20" 9¼"–117⁄ 8" 7" 11¼"–16" 14"–20" Hanger HU7 HU11 HUS1.81/10 HHUS48 HHUS410 HGUS410 HGUS414 HHUS5.50/10 HGUS5.50/12 HGUS5.50/14 HGU5.50 HGUS7.25/10 HGUS7.25/12 HGU7.25 HGUS7.25/14 HHGU7.25 Nail Type Header Joist 16d 10d x 11/2" 16d 10d x 11/2" 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d SDS ¼" x 2½" SDS ¼" x 2½" 16d 16d 16d 16d SDS ¼" x 2½" SDS ¼" x 2½" 16d 16d SDS ¼" x 2½" SDS ¼" x 2½" Allowable Load (lbs)—100% Support Member Material LSL, LVL, PSL DF/SP SPF 1,610(1) 1,610(1) 1,390(1) 2,950(1) 2,950(1) 2,550(1) 4,900 4,900 4,355 3,885 3,885 3,275 5,190 5,190 4,385 8,780 8,780 7,365 10,015 10,015 7,890 5,190 5,190 4,385 9,155 9,155 7,690 10,015 10,015 8,415 14,145 14,145 10,185 8,780 8,780 7,595 9,835 9,835 8,260 14,145 14,145 10,185 11,110 11,110 9,330 17,845 17,845 12,850 WPU MIT GLTV HGLTV HU HGUS 71⁄4" minimum depth support member required (HGLTV only) Hanger information on these two pages was provided by either Simpson Strong‑Tie® or USP Structural Connectors ®. For additional information, please refer to their literature. (1) Value may be increased for duration of load. General Notes ■ ■ Hanger capacity may be more or less than that of the supported member; therefore, check both the hanger and the beam capacities. 1⁄16" clearance (1⁄8" maximum) between the end of the beam or header and Leave its support member or hanger. Header Assumptions ■ ■ Hangers to be supported by headers of TimberStrand® LSL, Microllam® LVL, Parallam® PSL, Douglas fir, southern pine, or spruce-pine-fir. ■ Face mount hangers to be supported by 1¾" width headers, minimum. Nailing Requirements Fill all round and positive-angle nail holes with the proper nails. –10d x 1½" nails are 0.148" dia. by 1½" long. –10d nails are 0.148" dia. by 3" long. –16d nails are 0.162" dia. by 3½" long. –For USP: 16d R.S. nails are (9 gauge) 0.148" dia. by 3½" long ring-shank nails. ■ When using top mount hangers in back-to-back applications, ensure that the supporting beam width is adequate to prevent hanger interference. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 40 FRAMING CONNECTORS Top Mount Hangers—USP Structural Connectors® Supported Member Width Supported Member Depth 91 ⁄4" 9½" 13 ⁄4" 11¼" 117⁄ 8" 14" 31 ⁄ 2 " 9¼" 9½" 11¼" 117⁄ 8" 14" 16" 18" 20" 51 ⁄4" 9¼" 9½" 11¼" 117⁄ 8" 14" 16" 18" 20" 7" 117⁄ 8" 14" 16" 18" Hanger BPH17925 PHXU17925 BPH1795 PHXU1795 BPH17112 PHXU17112 BPH17118 PHXU17118 BPH1714 PHXU1714 PHXU35925 PHXU3595 PHXU35112 PHXU35118 HLBH3514 HLBH3516 HLBH3518 PHXU3520 HLBH3520 PHXU55925 PHXU5595 PHXU55112 PHXU55118 HLBH5514 HLBH5516 PHXU5518 HLBH5518 PHXU5520 HLBH5520 PHXU71118 HLBH7114 HLBH7116 HLBH7118 Nail Type Header 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d NA16D-RS NA16D-RS NA16D-RS 16d NA16D-RS 16d 16d 16d 16d NA16D-RS NA16D-RS 16d NA16D-RS 16d NA16D-RS 16d NA16D-RS NA16D-RS NA16D-RS Joist 10d x 11 ⁄ 2" 10d x 11 ⁄ 2" 10d x 11 ⁄ 2" 10d x 11 ⁄ 2" 10d x 11 ⁄ 2" 10d x 11 ⁄ 2" 10d x 11 ⁄ 2" 10d x 11 ⁄ 2" 10d x 11 ⁄ 2" 10d x 11 ⁄ 2" 10d 10d 10d 10d 16d 16d 16d 10d 16d 10d 10d 10d 10d 16d 16d 10d 16d 10d 16d 10d 16d 16d 16d Allowable Load (lbs)—100% (1) Support Member Material LSL, LVL, PSL DF/SP SPF 3,340 3,030 2,180 4,420 4,420 3,155 3,340 3,030 2,180 4,420 4,420 3,155 3,340 3,030 2,180 4,420 4,420 3,155 3,340 3,030 2,180 4,420 4,420 3,155 3,340 3,030 2,180 4,420 4,420 3,155 5,785 5,285 3,590 5,785 5,285 3,590 5,785 5,285 3,590 5,785 5,285 3,590 9,600 9,600 8,560 9,600 9,600 8,560 9,600 9,600 8,560 5,785 5,285 3,590 9,600 9,600 8,560 5,785 5,285 3,590 5,785 5,285 3,590 5,785 5,285 3,590 5,785 5,285 3,590 9,600 9,600 8,560 9,600 9,600 8,560 5,785 5,285 3,590 9,600 9,600 8,560 5,785 5,285 3,590 9,600 9,600 8,560 5,785 5,285 3,590 9,600 9,600 8,560 9,600 9,600 8,560 9,600 9,600 8,560 BPH PHXU HLBH HD THD THDH (1) Maximum load for top mount hangers may not be increased for duration of load. Face Mount Hangers—USP Structural Connectors® Supported Member Width Supported Member Depth 9¼"–14" 1¾" 11¼"–14" 14" 9¼"–14" 3½" 11¼"–18" 14"–20" 9¼"–117⁄ 8" 5¼" 11¼"–16" 11¼"–18" 14"–20" 9¼"–14" 7" 11¼"–16" 14"–18" Hanger HD17925 THD179 HD17112 HD1714 HD410 THD410 HD412 THD412 THDH412 HD414 THD414 THDH414 HD5210 THD610 THDH610 THDH612 THD612 THD614 THDH614 HD7100 THDH7210 HD7120 THDH7212 HD7140 THDH7214 Nail Type Header 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d 16d Joist 10d x 11 ⁄ 2" 10d x 11 ⁄ 2" 10d x 11 ⁄ 2" 10d x 11 ⁄ 2" 10d 10d 10d 10d 16d 10d 10d 16d 10d 10d 16d 16d 10d 10d 16d 10d 16d 10d 16d 10d 16d Allowable Load (lbs)—100% Support Member Material LSL, LVL, PSL DF/SP SPF 2,540(1) 2,540(1) 2,080(1) 5,360(1) 5,360(1) 4,210(1) 2,870(1) 2,870(1) 2,080(1) 3,100(1) 3,100(1) 2,280(1) 2,540(1) 2,540(1) 2,180(1) 5,360(1) 5,360(1) 4,600(1) 3,100(1) 3,100(1) 2,660(1) 6,770(1) 6,770(1) 5,810(1) 9,845 9,845 8,270 3,385(1) 3,385(1) 2,905(1) 7,045 7,045 5,920 9,845 9,845 8,270 2,540(1) 2,540(1) 2,180(1) 5,660(1) 5,660(1) 4,900(1) 8,725(1) 8,725(1) 7,520(1) 9,935 9,935 8,345 7,150(1) 7,150(1) 6,190(1) 8,415 8,415 7,070 11,645 11,645 9,780 1,690(1) 1,690(1) 1,450(1) 8,260(1) 8,260(1) 7,120(1) 2,255(1) 2,255(1) 1,935(1) 9,845 9,845 8,270 2,820(1) 2,820(1) 2,420(1) 9,845 9,845 8,270 See General Notes on page 40 (1) Value may be increased for duration of load. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 41 COLUMNS Allowable Axial Loads (lbs) for 1.3E TimberStrand® LSL Column Bearing Type On Column Base On Wood Plate (1) Effective Column Length 3' 4' 5' 6' 7' 8' 9' 10' 12' 14' 3'–7' 8' 9' 10' 12' 14' 100% 10,750 9,795 8,615 7,330 6,135 5,140 4,345 3,705 2,775 2,150 5,425 5,140 4,345 3,705 2,775 2,150 3½" x 3½" 115% 125% 12,155 13,055 10,895 11,575 9,375 9,820 7,810 8,085 6,450 6,625 5,355 5,480 4,500 4,590 3,825 3,890 2,845 2,885 2,195 2,220 5,425 5,425 5,355 5,425 4,500 4,590 3,825 3,890 2,845 2,885 2,195 2,220 100% 13,440 12,245 10,765 9,160 7,670 6,430 5,430 4,635 3,470 2,685 6,650 6,430 5,430 4,635 3,470 2,685 3½" x 4 3 ⁄ 8" 115% 125% 15,190 16,320 13,620 14,470 11,715 12,275 9,760 10,105 8,060 8,280 6,695 6,850 5,625 5,735 4,780 4,860 3,560 3,610 2,745 2,775 6,650 6,650 6,650 6,650 5,625 5,735 4,780 4,860 3,560 3,610 2,745 2,775 100% 16,895 15,395 13,535 11,515 9,645 8,080 6,825 5,825 4,360 3,380 8,225 8,080 6,825 5,825 4,360 3,380 Column Size 3½" x 5½" 115% 125% 19,095 20,515 17,120 18,190 14,730 15,430 12,270 12,700 10,130 10,410 8,420 8,610 7,070 7,210 6,005 6,110 4,475 4,535 3,450 3,490 8,225 8,225 8,225 8,225 7,070 7,210 6,005 6,110 4,475 4,535 3,450 3,490 100% 22,275 20,295 17,840 15,180 12,710 10,650 9,000 7,675 5,750 4,455 10,150 10,150 9,000 7,675 5,750 4,455 3½" x 7¼" 115% 125% 25,175 27,045 22,565 23,980 19,415 20,340 16,175 16,740 13,355 13,725 11,095 11,350 9,320 9,505 7,920 8,055 5,895 5,980 4,550 4,600 10,150 10,150 10,150 10,150 9,320 9,505 7,920 8,055 5,895 5,980 4,550 4,600 100% 26,495 24,140 21,225 18,060 15,120 12,670 10,705 9,135 6,840 5,300 12,075 12,075 10,705 9,135 6,840 5,300 3½" x 8 5⁄ 8" 115% 125% 29,945 32,170 26,845 28,525 23,095 24,195 19,245 19,920 15,890 16,325 13,200 13,505 11,090 11,310 9,420 9,585 7,015 7,115 5,410 5,475 12,075 12,075 12,075 12,075 11,090 11,310 9,420 9,585 7,015 7,115 5,410 5,475 (1) See connection details below. Allowable Axial Loads (lbs) for 1.8E Parallam® PSL Column Bearing Type On Column Base Effective Column 3½" x 3½" 3½" x 5¼" Length 100% 115% 125% 100% 115% 125% 100% 6' 10,595 11,200 11,545 15,890 16,800 17,320 21,190 7' 8,735 9,140 9,370 13,105 13,710 14,060 17,475 8' 7,265 7,550 7,715 10,900 11,325 11,570 14,535 9' 6,115 6,320 6,440 9,170 9,480 9,660 12,225 10' 5,200 5,355 5,445 7,800 8,035 8,170 10,400 12' 3,885 3,980 4,030 5,825 5,965 6,050 7,765 14' 3,000 3,065 3,100 4,500 4,595 4,645 6,005 16' 18' 20' Slenderness ratio exceeds 50 22' 24' Column Size 3½" x 7" 5¼" x 5¼" 115% 125% 100% 115% 125% 22,395 23,095 33,295 36,675 38,735 18,280 18,745 30,010 32,545 34,030 15,100 15,425 26,650 28,490 29,555 12,640 12,880 23,475 24,835 25,620 10,715 10,895 20,660 21,695 22,290 7,955 8,065 16,160 16,805 17,175 6,125 6,195 12,890 13,315 13,560 10,480 10,775 10,950 8,670 8,885 9,010 7,285 7,445 7,535 100% 40,000 40,000 35,530 31,300 27,545 21,545 17,185 13,970 11,560 9,710 5¼" x 7" 115% 125% 40,000 40,000 40,000 40,000 37,985 39,410 33,115 34,165 28,925 29,725 22,405 22,900 17,755 18,080 14,370 14,595 11,850 12,010 9,925 10,050 100% 40,000 40,000 40,000 40,000 40,000 40,000 34,155 28,485 24,020 20,475 17,630 15,325 Top or Bottom Plate Connection General Notes Tables are based on: – Solid, one-piece column members used in dry-service conditions. – Bracing in both directions at column ends. –NDS® 2005. –Compression perpendicular-to-grain stress of 400 psi adjusted per the NDS® 2005, 3.10.4. –Simple columns with axial loads only. For side loads or other combined bending and axial loads, see the NDS® 2005. ■ ■ ■ Two 16d (0.162" x 3½") nails for every 1¾" of column width, nailed through the plate into the column Allowable loads have been adjusted to accommodate the worst case of the following eccentric conditions: 1⁄6 of column thickness (first dimension) or 1⁄6 of column width. Beams and columns must remain straight to within L is the unrestrained length of the member in feet. 5L2⁄4608 (in.) of true alignment. For column allowable design stresses see page 5. Wide face of strands Wide face of strands 7" x 7" 115% 40,000 40,000 40,000 40,000 40,000 40,000 35,785 29,640 24,860 21,110 18,125 15,715 In order to use the manufacturer’s published capacities when designing column caps, bases, or holdowns for uplift, the bolts or self-drilling screws must be installed perpendicular to the wide face of strands as shown at left. DO NOT install bolts or screws into the narrow face of strands The column and connector values listed are for dry-service conditions only. When wet-service c onditions exist, contact your Weyerhaeuser representative for other p roduct solutions. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 42 125% 40,000 40,000 40,000 40,000 40,000 40,000 36,720 30,300 25,345 21,475 18,405 15,935 COLUMNS Column Caps for TimberStrand® LSL and Parallam® PSL Column Product Beam Width Column Size 3½" x 3½" 1.3E TimberStrand ® LSL 31 ⁄ 2 " 3½" x 5½" 3½" x 7¼" 3½" x 3½" 31 ⁄ 2 " 3½" x 5¼" 5¼" x 3½" 1.8E Parallam ® PSL 51 ⁄4" 5¼" x 5¼" 5¼" x 7" 7" x 3½" 7" 7" x 5¼" 7" x 7" Location on Beam End Intermediate End Intermediate End Intermediate End Intermediate End Intermediate End Intermediate End Intermediate End Intermediate End Intermediate End Intermediate End Intermediate Simpson Strong-Tie ® Connector Load (lbs) ECC44 7,655 CC44 15,310 ECC46 12,030 CC46 24,060 ECC48 16,405 CC48 24,060 ECC44 7,655 CC44 15,310 ECC46 12,030 CC46 24,060 ECC64 12,030 CC64 37,810 ECC66 18,905 CC66 37,810 24,060 ECC6-71 ⁄8 CC6-71 ⁄8 37,810 18,375 ECC71 ⁄8-4 CC71 ⁄8-4 68,250 28,875 ECC71 ⁄8-6 CC71 ⁄8-6 68,250 ECC71 ⁄8-71 ⁄8 36,750 CC71 ⁄8-71 ⁄8 68,250 Beam on Column Cap USP Structural Connectors ® Connector Load (lbs) KECC44 13,090 KCC44 16,660 KECC46 20,230 KCC46 24,065 KECC48 22,610 KCC48 26,180 KECC44 14,440 KCC44 18,375 KECC45 19,690 KCC45 28,875 KECC54 29,530 KCC54 43,315 KECC55 24,610 KCC55 43,315 KECC57 37,405 KCC57 43,315 KECC74 53,155 KCC74 65,815 KECC75X 55,125 KCC75X 68,250 KECC77X 55,125 KCC77X 68,250 P1 Column Base P2 Elevated Column Base Column Bases for TimberStrand® LSL and Parallam® PSL Column Product 1.3E TimberStrand ® LSL Column Size ABA44 6,000 CB44 Post or concrete control 31 ⁄ 2" x 5½" CB46 Post or concrete control 3½" x 7¼" CB48 LCB44 CB44 Post or concrete control 3½" x 3½" 3½" x 3½" 1.8E Parallam ® PSL Simpson Strong-Tie ® Connector Load (lbs) 3½" x 5¼" CB46 3½" x 7" CB71 ⁄8-4 5¼" x 5¼" CB66 5¼" x 7" 7" x 7" Post or concrete control CB6-7 CB71 ⁄8-6 CB71 ⁄8-7 USP Structural Connectors ® Connector Load (lbs) PA44 5,135 PAU44 6,775 CBS44 6,775 KCB44 Post or concrete control PA46 6,285 KCB46 Post or concrete control KCB48 Post or concrete control CBE44 KCB44 CBE46 KCB45 KCB47 Post or concrete control KCB74 CBE66 KCB55 KCB57 KCB76 KCB77 General Notes Capacities shown cannot be adjusted for duration of load. ■ Connector capacities assume a beam material with a minimum perpendicular-to-grain bearing of 625 psi. ■ P3 Beam on Column 1¼" TimberStrand® LSL or 11⁄8" TJ® rim board or blocking for lateral support L1 ■ ■ Optional non-shrink grout Connector capacities may be more than the c olumn capacity; therefore, check both the connector and the column capacity and use the lower capacity. Other connectors may be available. Capacities may vary depending on orientation of member. Contact the hanger manufacturer for more information. Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | May 2012 43 Column We Can Help You Build Smarter You want to build solid and durable structures—we want to help. Weyerhaeuser provides high-quality building products and unparalleled technical and field assistance to support you and your project from start to finish. Floors and Roofs: Start with the best framing components in the industry: our Trus Joist® TJI® joists; TimberStrand® LSL rim board; and TimberStrand® LSL, Microllam® LVL, and Parallam® PSL headers and beams. Pull them all together with our self-gapping and self-draining Weyerhaeuser Edge Gold™ floor panels and durable Weyerhaeuser roof sheathing. Walls: Get the best value out of your framing package—use TimberStrand® LSL studs for tall walls, kitchens, and bathrooms, and our traditional, solid-sawn lumber everywhere else. Cut down installation time by using TimberStrand® LSL headers for doors and windows, and Weyerhaeuser wall sheathing with its handy two-way nail lines. Use our TJ® Shear Brace for extra support in walls with large openings or in high wind or seismic areas. Software Solutions: Whether you are a design professional or lumber dealer, Weyerhaeuser offers an array of software packages to help you specify individual framing members, create cut lists, manage inventories—even help you design a complete structural frame. Contact your Weyerhaeuser representative to find out how to get the software you need. Technical Support: Need technical help? Weyerhaeuser has one of the largest networks of engineers and sales representatives in the business. Call us for help, and a skilled member from our team of experts will answer your questions and work with you to develop solutions that meet all your structural framing needs. CONTACT US 1.888.453.8358 • woodbywy.com/contact Contact your local representative or dealer at: Visit www.woodbywy.com/warranty for copies of this and other Trus Joist® Engineered Wood Product warranties. May 2012 • Reorder TJ-9000 This document supersedes all previous versions. If this is more than one year old, contact your dealer or Weyerhaeuser rep. ,Weyerhaeuser, Forte, Javelin, Microllam, Parallam, TimberStrand, TJ, TJI, and Trus Joist are registered trademarks and Edge, Edge Gold, and TJ-Pro are trademarks of W eyerhaeuser NR. © 2012 Weyerhaeuser NR Company. All rights reserved. Printed in the USA.
Similar documents
snow roof load tables - Standard Building Supplies Ltd.
Non-Snow Roof Load Tables TimberStrand® LSL Microllam® LVL Parallam® PSL Beam Details Window and Door Header Details Nailing on Narrow Face Allowable Holes Bearing Length Requirements Tapered End C...
More informationTimberStrand, Microllam, and Parallam Beams
• Uniform and Predictable • Minimal Bowing, Twisting, and Shrinking • Strong and Straight • Limited Product Warranty
More informationTimberStrand, Microllam, and Parallam Beams
Trus Joist® Beam, Header and Column Specifier's Guide TJ-9000 | July 2016
More informationTimberStrand, Microllam, and Parallam Beams
Technical Resource Sheet, #TJ-7501, or contact your Weyerhaeuser representative.
More informationBeam, Header, and Column Guide, 2015
• Lateral support is required at bearing and along the span at 24" on-center, maximum. • Bearing lengths are based on each product’s bearing stress for applicable grade and orientation. • All membe...
More information