STEEL DECK FASTENING SYSTEMS
Transcription
STEEL DECK FASTENING SYSTEMS
STEEL DECK FASTENING SYSTEMS 2014 Supplement to Hilti North American Product Technical Guide Hilti. Outperform. Outlast. Steel Deck Fastening Systems Why use Hilti steel deck fastening systems? Innovative Hilti deck fastening systems offer many advantages to the steel erector, contractor, structural engineer, architect, building official and owner. RELIABILITY • Ductileandtough,knurledshanksteelfasteningsimproveresistancetowindandseismicforces • Consistentperformanceinroughprojectsiteconditions,largelyindependentofoperatorskilllevel • CodecompliantandtestedtothelatestICC-ESAC43requirementsforIBCrecognition. • FMandULapprovedforwindandfireresistance;SDIandCSSBIlisted PRODUCTIVITY • Ergonomicstand-updeckfasteningtoolswithfasteningspeedssignificantlyfasterthanothermeans(e.g. welding,screwing,punching) • Quickset-uptimeforloading,re-loadingandtroubleshooting;lesserectiontimeinthecontrolleddeckingzone • TotalinstalledcostscanbesignificantlylessthanAWSarcspotpuddlewelding;nospecialtoolsrequiredfor proprietarydecktypes • UseOnDemandandToolFleetManagementtoolplacementoptionsforerectors TECHNICAL SUPPORT • Localfieldengineersandsteelandmetalprojectspecialistsavailabletoassistwithtrainingandguidanceon designandspecification • Professionaldeckingsubmittalsforsteelerectorscontractors • ProfisDFDiaphragmDesignSoftwarewithoptimizationfeaturesforstructuralengineers • Designloadtables,guidelinespecificationsandCADdetails SAFETY TRAINING • HiltiDeckFasteningTrainingManual • FreeANSIA10.3OperatorSafetyTrainingandmanufacturerlicensing • LocalHiltiAccountManagersandFieldEngineersavailableonthejobsite,everyday,toassistinmakingsure steelerectorsknowhowtodoitrightthefirsttime HEALTH, SAFETY AND WELFARE • Self-containedfasteningsystemdesignedtothehighestlevelofsafety • Noassociatedworkerhealthhazardssuchastoxicfumesfromwelding • Noburns,nofirehazards,noelectricalpowercordsortrippingandfallhazards • Reducedworkerbackstresswithergonomicstand-upfasteningtools APPEARANCE • Nounsightlyweldburnthrough;noneedfortouchuppaintorzinccoatingsaswhendamaged bywelding • Easyvisualidentificationofproperinstallation • Cleanfasteningappearancewithreducedneedforre-fastening Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 Steel Deck Fastening Systems Deck Fastening Technical Guide Table of Contents SectionDescription Page 1.1 1.1.1 1.1.2 1.1.3 1.1.4 1.1.5 1.1.6 1.1.7 1.1.8 1.1.9 1.2 Steel Deck Fastener Design and Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Terminology and Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Steel Deck Diaphragm Design and Theory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Fastener, Tool and Cartridge Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Submittal Information for Roof Deck . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Submittal Information for Floor Deck . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Fastener Quantity Estimation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Common Steel Deck Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Diaphragm Shear and Stiffness Calculations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 How to use Diaphragm Shear Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 X-HSN24 for Fastening Deck to Bar Joist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 1.3 X-ENP-19 for Fastening Deck to Structural Steel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 1.4 Racing Tip Screw Deck Fastening System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 1.5 SLC Sidelap Connectors for Fastening Deck to Deck . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 1.6 1.7 Optimized Diaphragm Shear Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 X-HVB Shear Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 X-HSN 24 fastener for attachment of many types of steel deck to bar joist from 1/8 inch to 3/8 inch thick X-ENP-19 fastener for attachment of many types of steel deck to structural steel greater than or equal to 1/4-inch thick Hilti S-MD 12-24x1-5/8 M HWH5 Racing Tip fastener for attachment of many types of steel deck to gauge purlin or thin bar joist S-SLC 01 and S-SLC 02 sidelap connectors and Hilti No. 10 HWH screws for many types and gauges of steel deck Mechanically attached X-HVB shear connector for use in composite beam construction with steel beams and concrete slabs X-HSN 24 Powder-Actuated and Racing Tip Screw Fastening Systems for Bar Joist or Gauge Purlin X-ENP-19 Fastening System for Structural Steel Hilti steel deck fastening systems have been extensively evaluated and hold all relevant building code approvals and evaluations including ICC-ES, COLA, FM and UL. SLC-01 and SLC-02 Sidelap Fastening Systems Please see the sections 1.2, 1.3, 1.4 and 1.5 for more information on specific product approvals, evaluations and application limits. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 1 Steel Deck Fastening Systems 1.1 Steel Deck Fastener Design and Selection 1.1. Terminology and Definitions 1.1.1.3 Steel Deck Definitions 1.1.1.1 Fastener Terminology Base Material - The existing part of the work that is a base for the fastening. The structural steel or bar joist framing members in steel deck applications. DX = Hilti terminology for direct fastening powder-actuated technology ENP = Hilti fastener type used for attaching steel deck to structural support steel with DX 76 and DX 860-ENP powder-actuated tools (X-ENP19 L15) F = diaphragm flexibility factor, micro-inch/lb (mm x 10-6/N) G' = diaphragm shear stiffness lb/in. (N/mm x 10-6) HSN = Hilti High Shear Nail fastener type for attaching steel deck to bar joist support steel used with DX 860-HSN and DX 460-SM powder-actuated tools (X-HSN 24) q = allowable diaphragm shear, plf (N/mm) Qf = structural connector strength, lb (kN) Qs = fastener strength, panel to panel, lb (kN) Sf = fastener flexibility factor, panel to frame, in./kip (mm/kN) Ss = fastener flexibility factor, panel to panel, in./kip (mm/kN) t f ( t || ) = flange thickness of beam or bar joist for steel deck applications, in. (mm) ICC-ES = International Code Council - Evaluation Service SDI = Steel Deck Institute CSSBI = Canadian Sheet Steel Building Institute 1.1.1.2 X -HVB Shear Connector Terminology hr = nominal rib height, in. (mm) Hs = connector height, in. (mm) Nr = number of connectors in one rib q = allowable shear strength, lb (kN) Qn = nominal shear strength, lb (kN) Rg = coefficient to account for group effect wr = average width of rib, in. (mm) Ycon = distance from top of steel beam to top of concrete slab, in. (mm) Beam - One of the principal horizontal supporting members of a building. Burn through - Unintended welding-related holes created in steel deck. Button punch - A mechanical means of connecting two pieces of sheet metal together by crimping with a special tool. This method is used on BI or interlocking deck panels. Direct fastening - A fastening method in which the fastenings are made without any preparation steps such as drilling a hole. Examples are powder-actuated fastening and self-drilling screws. Diaphragm deck - A decking system which is designed to carry lateral loads due to wind or seismic action in addition to gravity loads and wind uplift. Endlap - The overlap of adjacent steel deck panels at the ends of the panels (end edges perpendicular to the steel deck panel fluting). Typically specified as 2 or 4 inches. Butted deck with no endlap is used for some steel deck (e.g., cellular). Fastener pattern - The number and spacing of fasteners at each support for a steel deck panel. Fastened material - The component that must be attached to the base or supporting material. Fastening - The combination of fastener, fastened material and base material all in final position. Fastening system - The fastener, fastening tool and driving power source all taken together as a system with specific performance characteristics. Gauge - A measure of thickness for sheet metal. Reference Section 1.1.7 for common steel deck gauges. Interlocking sidelap (BI Connection) - Steel deck panels having male and female side edges. The adjacent deck panel male and female edges interlock into each other when the deck is installed. The interlocks are fastened together using button punches, proprietary punch systems, welds, or screws. Joist - A structural member in a building which is used to support a floor or roof. 2 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 Steel Deck Fastening Systems Steel Deck Fastener Design and Selection 1.1 Nestable sidelap - Steel deck type in which the side edge of a steel deck panel contains a partial valley profile and overlaps, or “nests" on top of the side edge of the adjacent steel deck panel, which contains a full valley profile. Often fastened together using self-drilling stitch screws. Non-diaphragm deck - A steel deck system which is designed to carry only gravity loads. Powder-actuated cartridge - A powder filled metal casing used as the source of driving energy in a powder-actuated tool. The ANSI A10.3 terminology is a “cased powder load." Powder-Actuated Fastener (PAF) - A nail or threaded stud fastener capable of being driven into steel, concrete or masonry. Fasteners may be equipped with washers suitable for clamping the fastened material to the base or supporting material. Also referred to as Hilti DX, powder-actuated fasteners (PAF), power-driven fasteners (PDF), drive pins or shot pins. Powder-actuated, Indirect-acting tool - A powder-actuated tool in which the expanding gas of the powder load acts on a captive piston, which in turn drives the fastener into the base material. If the test velocity of the lightest fastener when using the strongest powder load is less than 328 fps (100 m/s), the tool meets the ANSI A10.3 requirements and is classified as a low-velocity tool. All Hilti powder-actuated tools used in the construction industry are classified as low-velocity. Pullout - As related to fasteners, a failure mode that occurs when the fastener pulls out of the base steel support. Pullover - As related to fasteners, a failure mode that occurs when the steel deck panel pulls over the fastener head or washer(s). Punch systems - A mechanical means of connecting two pieces of sheet metal together by punching through the steel to create a flap of metal which is then crimped. This is done with a proprietary pneumatic tool on interlocking deck panels. Purlin - A secondary horizontal structural member attached to the primary frame and supporting the roof covering. Sidelap - The side edge overlap of adjacent steel deck panels (side edges parallel to the steel deck panel fluting). Stitch screws - Screws used to fasten the overlapping edges of two deck panels between joists or beams. Tack weld - A weld of no structural significance. Used for temporary attachment of steel to the supporting frame. A weld made to hold the parts in proper alignment until the final welds are made. Uplift - Vertical load on the steel deck panels due to wind forces. Wind tacking - Limited fastening of the steel deck panel at the edges to hold the panels in place until all specified fastenings have been made. Profis DF Diaphragm Software - Hilti developed, revolutionary design and submittal generator program. It incorporates a powerful design optimization feature to produce cost-effective and reliable steel deck solutions. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 3 Steel Deck Fastening Systems 1.1 Steel Deck Fastener Design and Selection 1.1.2 Steel Deck Diaphragm Design and Theory 1.1.2.1 General Discussion A steel deck diaphragm is a horizontal assembly that resists wind, seismic and other lateral forces. A diaphragm can be modeled as a horizontal beam with interconnected floor and roof deck units that act as the beam web. Intermediate joists or beams act as web stiffeners and perimeter beams or reinforcement on the diaphragm perimeter act as the beam flanges. Figure 1, based on graphics from the Steel Deck Institute (SDI) Diaphragm Design Manual, depicts a roof deck diaphragm model. Design of steel deck diaphragms has traditionally been done using the Steel Deck Institute (SDI) Diaphragm Design Manual or Technical Manual (TM) 5-809-10 Seismic Design for Buildings, Departments of the Army, Navy and Air Force (Tri-Services Design Manual). Both methods provide the basic equations for determining the strength and stiffness of the diaphragm considering the following parameters: 1. Steel Deck Profile Type and Thickness 2. Supporting Steel Frame Spacing or Deck Span 3. Frame Fastener Type and Spacing (connector for steel deck to steel frame) 4. Sidelap Fastener Type and Spacing (connector for steel deck panel edge to edge) 5. Safety Factors (ASD) or Resistance Factors (LRFD/LSD) based on load type (wind, seismic, other) and fastening type (mechanical, weld) ICC Evaluation Services recognizes both design methods as acceptable in AC43, Acceptance Criteria for Steel Deck Roof and Floor Systems. An ICC Evaluation Service Report (ESR) based on ICC-ES AC43 provides recognition for use with the IBC. Hilti deck fasteners are currently listed in the SDI DDM03 and Appendix VI, VII and VIII and were evaluated in ICC-ES ESR-3592, ESR-2776 and ESR-2197. Hilti deck fastener performance with proprietary sidelap clinching systems is also documented in ESR-1735P, ESR-1116, ESR-1169, ESR-1414 and ESR-2408. Additional industry research on quasi-static and seismic/cyclic load performance of diaphragms is ongoing. Other system approvals and evaluation reports are pending. Figure 1: Diaphragm Model 1.1.2.2 Fastener Test Programs Many small element and full scale test programs have been conducted using Hilti deck fasteners to evaluate their performance. 1. Small Element Connection Tests Small element connection tests are used to determine fastener pullout, pullover and lap-joint shear strength and stiffness with sheet steel and base steel representative of typical construction. The data is analyzed and used in a predictive model to calculate the performance of the larger steel deck diaphragm assembly or system. These tests are conducted in accordance with the following standards, and shown in Figure 2. • AISI S905 Test Methods for Mechanically Fastened ColdFormed Steel Connections • ASTM E1190 Standard Test Methods for Strength of Power-Actuated Fasteners Installed In Structural Members • ICC-ES AC70 Acceptance Criteria for Fasteners Power Driven Into Concrete, Steel and Masonry Elements • ICC-ES AC118 Acceptance Criteria for Tapping Screw Fasteners 4 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 Steel Deck Fastening Systems Steel Deck Fastener Design and Selection 1.1 Figure 2: Small Element Connection Tests 2. Full Scale Diaphragm System Tests Full scale diaphragm system tests are used to determine the strength and stiffness of a larger steel deck diaphragm assembly directly. The data is analyzed and fit in a predictive model to address varying configurations of base steel, steel deck, specific fastener combinations and spans. These tests are conducted in accordance with the following standards and shown in Figures 3, 4 and 5. • ICC-ES AC43 Acceptance Criteria for Steel Deck Roof and Floor Systems • AISI S907 Cantilever Test Method for Cold-Formed Steel Diaphragms • ASTM E455 Standard Test Method for Static Load Testing of Framed Floor or Roof Diaphragm Constructions for Buildings Figure 3: ICC-ES AC43 Diaphragm Test Frame Schematics 30 '-0 " " 24'-0 Figure 4: AC43 Diaphragm Test Frame Fastening Systems Research Laboratory (FSRL), Schaan, Liechtenstein Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 5 Steel Deck Fastening Systems 1.1 Steel Deck Fastener Design and Selection Load (kips) Hilti powder-actuated deck fasteners are recognized alternatives to arc spot puddle welds and self-drilling screws. The fasteners can be used on roof deck diaphragms as well as composite concrete filled floor diaphragms. Hilti provides training for powder-actuated tool operators in accordance with ANSI A10.3 Safety Requirements for Powder-Actuated Fastening Systems. Displacement [inch] Figure 5: AC43 Deck Diaphragm Load Displacement Curve Hilti Mechanical Fastening Systems Provide Superior Solutions for Attaching Steel Deck to Steel Support Members • Consistent Fastening Quality • High Production Rate • No Burn Throughs or Joist Damage from Welding • Superior Cyclic Load Performance 1.1.2.3 Proper Fastener Selection and Steel Deck Layout (Pre-Fastener Installation) Selection of the proper Hilti deck fastener depends on the supporting base steel thickness as shown in Section 1.1.3.1. The Hilti Deck Fastener Selection Gauge shown in Figure 6 should be used by the decking installer to confirm fastener selection. The cut-out slot on the gauge is fit against the bar joist top chord or steel beam flange. As the internal card slides in the gauge, the proper Hilti deck fastener is highlighted with a green box. A red box indicates that the corresponding Hilti deck fastener is outside the base material application limits and should not be used for steel deck fastening to the base material being gauged. Figure 6: Hilti Deck Fastener Selection Gauge Steel deck installers must layout deck properly and mark frame fastening lines in order to ensure that steel deck panels are connected to the supporting steel frame. Marking frame fastening lines is essential when attaching steel deck to thin base steels (tII < 1/4"), including open web steel joists. For all applications, the fasteners should be installed at least 3/8" (10 mm) from the edge or toe of the joist top chord or light steel beam flange. Additionally, when installing into a bar joist top chord (angle), the fasteners need to be installed at a distance from the angle, bx ≤ 8 x tII. Reference Figure 7 for edge distance and bx dimensions. Rolled beam or wide flange shape Angles or joist top chords bx t || ≥ 3/8" t || ≥ 3/8" bx ≤ 8 t || Figure 7: Edge Distance Recommendations Extra care must be taken at the endlap and corner lap conditions where multiple layers of steel deck nest or interlock on adjacent panels. It is particularly important that endlap and corner lap conditions of two and four deck layers must be snug and tight against one another and the supporting steel frame in order for the fastening to be made as shown in Figure 8. Tight endlap and corner lap requirements are independent of the fastening type and contribute directly to the performance of arc spot welds, screws, powder-actuated fasteners, punches and crimps/clinches. If the steel deck endlaps and corner laps are not tight, a proper fastening cannot be made. Figure 8: Tight Nesting of Steel Deck Sheets 6 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 Steel Deck Fastening Systems Steel Deck Fastener Design and Selection 1.1 1.1.2.4 Fastener Inspection (Post-Fastener Installation) Steel deck construction projects may present a challenge with respect to the quality control of connections between sheet steel and the supporting steel structure. Quality control for traditional fastening methods may present a challenge as they typically consist of visual checks and dimensional or size verifications, which may or may not confirm a proper fastening. Field verification of the adequacy of powderactuated mechanical steel deck fastenings can be conducted as described in this section. Section 1.1.2.3). The fastener point must penetrate into, but not necessarily through, the supporting steel (top chord or flange), depending on the fastener/deck/base steel configuration. The use of mechanical fasteners does not imply a need to inspect every fastening point unless specified by the Structural Engineer. No guideline standards are published by SDI, AWS, AISC or OSHA for percentages of steel deck connections that must be checked or that can be unsatisfactory. This determination must be made by the Structural Engineer and Authority Having Jurisdiction. 3. Washer placement and condition. In general, the fastener washer edges must be clamping the steel deck sheet to the base steel. The washers should not curl upwards away from the deck surface and must not be digging or cutting into the steel deck surface. For the X-HSN 24 fastener, the top hat washer must be compressed. For the X-ENP-19 fastener, the piston mark (indentation) should be clearly visible on the fastener washer as shown in Figure 10. Hilti has multiple services and aids in place that help ensure steel deck fastenings are done correctly the first time. Together with a commitment to field quality control by the steel deck installer, these systems may alleviate the need for postfastener installation inspection. Hilti has over one thousand Account Managers and Field Engineers available for training steel deck installers. This handson training includes the use of the Hilti Powder-Actuated Tools in accordance with ANSI Figure 9: A10.3 safety requirements, use Hilti Power of the Deck Fastener Selector Adjustment Guide Gauge, proper steel deck layout and end/corner lap nesting as discussed in Section 1.1.2.3. Proper powder-actuated fastener, tool and cartridge selection as discussed in Section 1.1.3, as well as the use of the Hilti Power Adjustment Guide, shown in Figure 9 and discussed in more detail in Section 1.1.3.3, are also key elements of the installer training. Furthermore, the Hilti DX 860-HSN tools come equipped with piston brakes, which virtually eliminate the possibility of overdriven fasteners. There are three main characteristics of proper fastenings that must be considered: 1. Fasteners installed in proper locations. The fasteners must be installed in the proper steel deck valleys or flutes in accordance with the structural roof and floor deck plans and design, and in the proper location in the base steel (Reference 2. Clamping of fastened part to base material. The fasteners must clamp the steel deck down to the base steel (top chord or flange). There should not be any visible gaps between the steel deck and the base steel or between steel deck laps. Piston Mark Figure 10: X-ENP-19 L15 Piston Mark (indentation) When the inspector is unclear about the compression of the top hat washer or the piston mark, the Hilti Power Adjustment Guide may be used to measure for optimal powder-actuated fastener nailhead stand-off, hNVS. Note that measuring nail head stand-off does not verify proper fastener embedment unless the steel deck and base material are tightly clamped, with the base steel not deformed or bent. Conversely, measuring nail head stand-off does not confirm an improper fastening. If slightly outside the range, further investigation into the three characteristics of proper fastenings given above should be completed. The following Figures 11 and 12 provide visual examples of proper and improper steel deck fastenings for Hilti powder-actuated bar joist (X-HSN 24) and structural steel (X-ENP-19 L15) fasteners, respectively. Inspection of the installed steel deck and installation of roof coverings, insulation and membrane should be done soon after steel deck installation to assist in alleviating corrosion or other issues that could arise due to long-term exposure. Fasteners must be completely protected from the weather within 180 days after installation. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 7 Steel Deck Fastening Systems 1.1 Steel Deck Fastener Design and Selection hNVS well above optimal range* Top Hat not collapsed, not snug against steel deck and not clamping deck sheet to base steel Figure 11a: Under Driven X-HSN 24 Fastener with Single Sheet to Base Steel hNVS within optimal range* Top Hat properly collapsed, snug against steel deck and clamping deck sheet to base steel Figure 11b: Properly Driven X-HSN 24 Fastener with Single Sheet to Base Steel hNVS well below optimal range* Washer cutting into deck sheet, deforming base steel and deck sheet Figure 11c: Over Driven X-HSN 24 Fastener with Single Sheet to Base Steel * Optimal stand-off (hNVS) range for the X-HSN 24 fastener is 5 mm ≤ hNVS ≤ 9 mm. 8 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 Steel Deck Fastening Systems Steel Deck Fastener Design and Selection 1.1 Piston mark (indentation) not visible on fastener Gap visible between washers hNVS well above optimal range* Washers not clamping deck sheet to base steel Figure 12a: Under Driven X-ENP-19 Fastener with Single Sheet to Base Steel. hNVS within optimal range* Piston mark (indentation) clearly visible on fastener Washers snug against one another and clamping deck sheet to base steel Figure 12b: Properly Driven X-ENP-19 Fastener with Single Sheet to Base Steel Washers cutting into deck sheet, deforming base steel and deck sheet hNVS well below optimal range* Figure 12c: Over Driven X-ENP-19 Fastener with Single Sheet to Base Steel * Optimal stand-off (hNVS) range for the X-ENP-19 fastener is 8.2 mm ≤ hNVS ≤ 9.8 mm. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 9 Steel Deck Fastening Systems 1.1 Steel Deck Fastener Design and Selection 1.1.3 Fastener, Tool and Cartridge Selection Solutions for bar joist (open web joists) applications (Reference Section 1.2 and 1.4) DX 460-SM SLC 01 SLC 02 #10 HWH DX 860-HSN X-HSN 24 or S-MD 12-24 x 1-5/8 M HWH5 (Racing Tip 5) Solutions for structural steel applications (Reference Section 1.3) SDT 5 DX 76 SLC 01 SLC 02 #10 HWH X-ENP-19 L15 DX 860-ENP-L SDT 5 10 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 Steel Deck Fastening Systems Steel Deck Fastener Design and Selection 1.1 1.1.3.1 Fastener Selection Table 1 - Bar joist and light structural steel frame fasteners (Reference Section 1.2 and 1.4) Base Material1 Fastener Type2 Recommended Installation Tool X-HSN 243 Bar Joist and Structural Steel 1/8" (3 mm) ≤ tf ≤ 3/8" (10 mm) DX 860-HSN S-MD 12-24x1-5/8 M HWH5 Gauge Purlin and Light Bar Joist 0.0598" (1.5 mm) ≤ tf ≤ 1/4" (6 mm) SDT 5 1 Steel base material strength (Fu ) shall be in the range of 58 to 91 ksi for base steel thicknesses (tf ) less than or equal to 5/16". For base steel thicknesses greater than 5/16", the tensile strength shall be in the range of 58 to 75 ksi. 2 The X-HSN 24 and Racing Tip Fastening Systems will fit in all deck types except A-deck. 3 This fastener can be used with structural steel within the thickness ranges shown. Table 2 - Structural steel frame fasteners (Reference Section 1.3) Base Material1 Fastener Type2 Structural Steel, Hardened Structural Steel and Heavy Bar Joist t f ≥ 1/4" (6 mm) X-ENP-19 L15 Recommended Installation Tool DX 860-ENP-L 1 Steel base material tensile strength (Fu ) shall be in a range of 58 to 91 ksi. 2 X-ENP-19 L15 fasteners fit in all types of deck except A and F. Table 3 - Deck-to-deck sidelap fasteners (Reference Section 1.5)2 Deck Gauges Fastener Type1 Recommended Installation Tool S-SLC 01 M HWH 18 to 26 SDT 5 3 S-SLC O2 MHWH 16 to 22 SDT 5 Hilti #10 HWH Screw 16 to 26 SDT 5 1 For use with all types of nestable deck or screwable interlocking deck. 2 Other sidelap connector types are possible with Hilti’s powder actuated frame fasteners. Please reference the Steel Deck Institute (SDI) Diaphragm Design Manual 3rd Edition (DDM03). 3 Use of S-SLC 01 M HWH with 18 gauge steel deck is recommended only for standard tensile strength (45 ≤ Fu≤ 65 ksi) steel deck. For high tensile strength (Fu > 65 ksi) 18 gauge steel deck, use S-SLC 02 M HWH. Sealing Caps The SDK2 is an SAE 316 stainless steel sealing cap with a neoprene seal. This is installed over the head of the X-ENP-19 fastener using the SDK2 hand setting tool. The SDK2 sealing cap provides added corrosion protection for exposed exterior steel deck applications in SDK2 Setting Tool accordance with IBC requirements. SDK2 Sealing Cap X-ENP-19 L15 hnvs = 8.2 mm- 9.8 mm Note: The sealing cap and fastener must be installed correctly to achieve a water-resistant seal. Contact Hilti for details. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 11 Steel Deck Fastening Systems 1.1 Steel Deck Fastener Design and Selection 1.1.3.2 Tool Selection Bar joist and light structural steel powder-actuated frame tools (Reference Section 1.2) DX 860-HSN The DX 860-HSN stand up decking tool is a fully automatic powderactuated tool designed for attaching steel deck to steel base materials. With a high fastening rate and 40-fastener magazine, the DX 860HSN can significantly help reduce the time it takes to attach deck. Fastenings can be made on very thin support structures without the need for weld washers. Suitable for base steels with a thickness of 1/8" to 3/8". Fastens X-HSN 24 collated fasteners. DX 460-SM The DX 460-SM decking tool is a medium duty powder-actuated tool with adjustable power regulation used for attaching steel deck to steel base materials. This system is best suited for deck with a flute width of 1/2" or greater and for base steels with a thickness of 3/16" to 3/8". Fastens X-HSN 24 collated fasteners. Structural steel powder-actuated frame tools (Reference Section 1.3) DX 860-ENP-L The DX 860-ENP-L is a fully automatic powder-actuated tool designed for attaching steel deck to structural steel beams. The tool has capacity of 1 strip of 40 cartridges and 4 flexible strips of 10 each X-ENP-19 fasteners in an MXR collated configuration. The DX 860-ENP-L is ergonomically designed to work in an upright position, and can be loaded without the operator bending over. The system is suitable for deck with a flute width of 3/4" or greater and base steels with a thickness of 1/4" or greater. DX 76 The DX 76 decking system is a heavy duty fastening system consisting of semi-automatic, low-velocity powder-actuated tool, fasteners and cartridges for attaching steel deck to steel base materials. Special features include cartridge power regulation which allows for high productivity. This system is suitable for deck with a flute width of 3/4” or greater and base steels with a thickness of 1/4” or greater. Use with X-ENP-19 fasteners in single, MX or MXR collated configurations. Gauge purlin and light bar joist screw frame tool and deck-to-deck sidelap fastening tool (Reference Section 1.4 or 1.5) SDT 5 The SDT 5 stand up decking tool is a steel deck sidelap and frame fastening tool. Combined with the DX 860-HSN or DX 860-ENP-L, these tools deliver a high speed, high productivity system for mechanical attachment of steel deck. The SDT 5 can consistently drive up to 50 S-MD 12-24x1-5/8 M HWH5 frame fasteners or SLC sidelap connectors before reloading. Its comfortable, durable design features an 18 position torque clutch to provide consistent fastening quality. In a competitive market, the SDT 5 represents a major gain in productivity essential to staying on time and on budget. 12 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 Steel Deck Fastening Systems Steel Deck Fastener Design and Selection 1.1 1.1.3.3 Powder-Actuated Cartridge and Power Regulation Selection When installing powder-actuated deck fasteners, it is important for the installed fasteners to have a nailhead stand-off, hNVS, within the specified range. The Hilti Power Adjustment Guide, shown in Figure 13, is a valuable quality assurance aid to the decking foreman. It is primarily intended for power adjustment of the powder-actuated tool. This is done by installing test fastenings into representative base steel and then checking the nailhead stand-off, hNVS, at the beginning of the work to achieve the optimal cartridge and tool power level. This is a critical step in the work because of variations in the structural steel strengths (Fy, Fu ) and member thicknesses. By investing time up front and properly correlating the fastening system to actual site materials, most fastening issues can be avoided. During installation, it is also advisable for the foreman to check the work periodically to spot deficiencies before large portions of the deck might be fastened incorrectly. Failure to properly set the tool, fastener and cartridge prior to starting work can decrease fastening quality consistency. Figures 14 and 15 provide the installer with a recommended cartridge color and power setting for Hilti bar joist and structural steel deck fasteners, respectively. These charts are guidelines that the installer can use to start the process of test fastenings discussed above. This also helps ensure the installer will have the proper color cartridges on the project site. Figure 13: Hilti Power Adjustment Guide Base material thickness tII [inches] Base material thickness tII [inches] Prior to starting work, the installer shall install a test fastening and check the hNVS using the Hilti Power Adjustment Guide. If necessary, the installer shall adjust the power or force that drives the fastener into the base steel. There are two ways to accomplish this power adjustment. One is by use of different cartridge colors and the other is by adjusting the power regulator on the tool itself. Cartridge colors available for Hilti decking tools are (in order of increasing power): yellow, blue, red and black. All Hilti decking tools come equipped with a power adjustment capability. The settings on the power regulation dials range from 1 to 4. X-HSN 24 Figure 14: Cartridge and Power Regulation Guidelines for Bar Joist Deck Fasteners installed with a DX 860-HSN1 X-ENP-19 Figure 15: Cartridge and Power Regulation Guidelines for Structural Steel Deck Fasteners1 1 Cartridge recommendations for the X-ENP-19 fastener are acceptable for all current Hilti Decking Tools for attachment to structural steel. Cartridge recommendations for the X-HSN 24 fasteners are for the DX 860-HSN. Cartridge recommendations for the DX 460-SM can be found in the tool operator manual. Recommendations are guidelines only and require verification on each site. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 13 Steel Deck Fastening Systems 1.1 Steel Deck Fastener Design and Selection 1.1.4 Submittal Information for Roof Deck Hilti Account Manager: Date: Phone: DDAATT: Decking Installer: Hilti Regional Field Engineer: Contact Name (Last, First): Phone: Installer Trained by Hilti: l Yes Fax/e-mail: l No, please schedule training Engineer of Record: Contact Name (Last, First): Phone: Fax/e-mail: Project Name: Project Zip Code: Total Area: Deck Manufacturer: Building Code: □ 2012 IBC □ 2009 IBC □ 2006 IBC □ Other Design Reference: □ SDI □ ICC-ES □ CSSBI □ Other Submittal Recipient: □ Account Manager □ Decking Installer Bar Str. Joist Steel Zone _______ Support Span (ft) _______ Support Steel □ □ □ Other: Design Diaphragm Shear Capacity (plf) ________ Subst. Frame:□ X-ENP-19 □ RT5 Subst. Sidelap: □ Hilti SLC □ # 10 Screw □ # 12 Screw □ X-HSN 24 □ Button Punch □ Proprietary Punch System Deck Type Deck Gauge Frame Type Frame Pattern □ B (1.5") □ 24 □ 1/2" PW □ 36 / □ 9 □ BI (1.5") □ 22 □ 5/8" PW □ 30 / □ 7 □ N (3") □ 20 □ 3/4" PW □ 24 / □ 5 □ Other □ 18 □ #12 or #14 Screw □ __ / □ 4 □ 16 □ Other □ 3 □ __ Sidelap Type Sidelap Pattern □ #10 Screw □ _____# Per Span □ #12 Screw □ _____(in.) On Center □ Button Punch □ _______(in.) Top Seam Weld Length □ Proprietary Punch System □ Other Bar Str. Joist Steel Zone _______ Support Span (ft) _______ Support Steel □ □ Bar Str. Base Thickness □ < 3/16" □ 3/16" □ 1/4" □ 5/16" □ 3/8" □ > 3/8" Design Diaphragm Shear Capacity (plf) ________ Subst. Frame:□ X-ENP-19 □ RT5 Subst. Sidelap: □ Hilti SLC □ # 10 Screw □ # 12 Screw □ X-HSN 24 □ Button Punch □ Proprietary Punch System Deck Type Deck Gauge Frame Type Frame Pattern □ B (1.5") □ 24 □ 1/2" PW □ 36 / □ 9 □ BI (1.5") □ 22 □ 5/8" PW □ 30 / □ 7 □ N (3") □ 20 □ 3/4" PW □ 24 / □ 5 □ Other □ 18 □ #12 or #14 Screw □ __ / □ 4 □ 16 □ Other □ 3 □ __ □ Exposed to Weather Sidelap Type Sidelap Pattern □ #10 Screw □ _____# Per Span □ #12 Screw □ _____(in.) On Center □ Button Punch □ _______(in.) Top Seam Weld Length □ Proprietary Punch System □ Other Joist Steel Zone _______ Support Span (ft) _______ Support Steel □ □ Base Thickness □ < 3/16" □ 3/16" □ 1/4" □ 5/16" □ 3/8" □ > 3/8" Design Diaphragm Shear Capacity (plf) ________ Subst. Frame:□ X-ENP-19 □ RT5 Subst. Sidelap: □ Hilti SLC □ # 10 Screw □ # 12 Screw □ X-HSN 24 □ Button Punch □ Proprietary Punch System Deck Type Deck Gauge Frame Type Frame Pattern □ B (1.5") □ 24 □ 1/2" PW □ 36 / □ 9 □ BI (1.5") □ 22 □ 5/8" PW □ 30 / □ 7 □ N (3") □ 20 □ 3/4" PW □ 24 / □ 5 □ Other □ 18 □ #12 or #14 Screw □ __ / □ 4 □ 16 □ Other □ 3 □ __ □ Exposed to Weather □ Exposed to Weather Sidelap Type Sidelap Pattern □ #10 Screw □ _____# Per Span □ #12 Screw □ _____(in.) On Center □ Button Punch □ _______(in.) Top Seam Weld Length □ Proprietary Punch System □ Other Base Thickness □ < 3/16" □ 3/16" □ 1/4" □ 5/16" □ 3/8" □ > 3/8" Notes Fax or email completed forms to Hilti Technical Support at (918) 459-3004 or deck@hilti.com. 14 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 Steel Deck Fastening Systems Steel Deck Fastener Design and Selection 1.1 1.1.5 Submittal Information for Floor Deck Hilti Account Manager: Date: Phone: DDAATT: Decking Installer: Hilti Regional Field Engineer: Contact Name (Last, First): Phone: Installer Trained by Hilti: □ Yes □ No, please schedule training Fax/e-mail: Engineer of Record: Contact Name (Last, First): Phone: Fax/e-mail: Project Name: Project Zip Code: Total Area: Deck Manufacturer: Building Code: □ 2012 IBC □ 2009 IBC □ 2006 IBC □ Other Design Reference: □ SDI □ ICC-ES □ CSSBI □ Other Submittal Recipient: □ Account Manager □ Decking Installer Bar Str. Joist Steel Zone _______ Support Span (ft) _______ Support Steel □ □ □ Other: Design Diaphragm Shear Capacity (plf) ________ Subst. Frame:□ X-ENP-19 □ RT5 Subst. Sidelap: □ Hilti SLC □ # 10 Screw □ # 12 Screw □ X-HSN 24 □ Button Punch □ Proprietary Punch System Deck Type Deck Gauge Frame Type Frame Pattern Sidelap Type Sidelap Pattern □ B (1.5") □ 28 □ 1/2" PW □ 36 / □ 9 □ #10 Screw □ _____ # Per Span □ BΙ (1.5") □ 26 □ 5/8" PW □ 30 / □ 7 □ #12 Screw □ _____ (in.) on Center □ N (3") □ 24 □ 3/4" PW □ 24 / □ 5 □ Button Punch □ 2" x 12" □ 22 □ #12 or #14 Screw □ __ / □ 4 □ ____ (in.) Top Seam Weld Length □ 3" x 12" □ 20 □ Other □ 3 □ Other □ 9/16" □ 18 □ __ □ Other □ 16 □ Normal Weight Concrete. . . □ 3000 psi □ Lightweight Concrete. . . . . □ 3500 psi □ 4000 psi Base Thickness □ < 3/16" □ 3/16" □ 1/4" □ 5/16" □ 3/8" □ > 3/8" _________(Inches) Concrete Depth Above Top of Flute □ Insulating Concrete. . . . . . . □ 130 psi □ Perform Calculations based on Shear Studs Present in Design Deck fastened at a 36/4 pattern with standing seam sidelaps fastened by button punches @ 36" O.C. maximum. Refer to ICC-ES ESR-2197, Tables 10-17, for more details. Minimum Concrete Shear Reinforcement □ .00075 bw s2 Minimum Average Spacing of Shear Studs □ 12" Minimum Welded Wire Fabric for Tabulated Shear Values □ 6 x 6 – W 1.4 x W 1.4 □ 6 x 6 – W 2.0 x W 2.0 □ 6 x 6 – W 2.9 x W 2.9 □ 6 x 6 – W 4.0 x W 4.0 □ 4 x 4 – W 4.0 x W 4.0 □ 6 x 6 – W 7.5 x W 7.5 □ 6 x 6 – W 8.3 x W 8.3 □ 18" □ .00025 bw s2 □ 24" □ 30" □ 36" Notes Fax or email completed forms to Hilti Technical Support at (918) 459-3004 or deck@hilti.com. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 15 Steel Deck Fastening Systems 1.1 Steel Deck Fastener Design and Selection 1.1.6 Fastener Quantity Estimation Table 4 - Frame fasteners per square of roof1,2,3 Fastener Pattern 36/11 36/9 36/7 36/5 36/4 36/3 30/6 30/4 30/3 24/5 24/3 24/4 Fastener spacing 4.0 6" 78 6" 61 6" 53 6-12-12-6 37 12" 29 18" 21 6" 53 6-18-6 34 12-18 24 6" 53 6" 29 8" 41 4.5 69 56 48 33 26 19 48 30 22 48 26 37 5.0 63 50 43 30 22 17 43 28 20 43 22 34 Support Spacing, ft 5.5 6.0 59 53 45 43 39 37 28 26 22 21 16 15 39 37 26 24 19 17 39 37 22 21 31 29 Sidelap fastener estimation 6.5 50 39 34 24 19 14 34 22 16 34 19 27 7.0 46 36 32 23 18 13 32 21 15 32 18 25 8.0 40 33 28 20 16 12 28 19 14 28 16 22 1 Hilti Profis DF Diaphragm software also estimates fastener quantities. 2 Estimated quantities are for one square of decking. A square of roof decking is an area of 100 ft 2. No provision is made for waste. Perimeter fastening spacing is based on 12" on-center assumption. 3 For interlocking sidelaps, add 15% to quantities in table. 1.1.7 Common Steel Deck Dimensions To estimate the number of sidelap screws on a steel roof or floor deck project, multiply the total deck area in square feet times the number of required stitch screws per span and then divide by the sheet width times the joist spacing (both in feet). A 5% contingency is also recommended for waste and loss. Example: Total area: . . . . . . . . . 50,000 square feet Sheet width:. . . . . . . . 36" = 3 ft Joist spacing:. . . . . . . 5 ft No. of sidelap fasteners per span: 5 # of screws needed = 50,000 ft2 x 5 x 1.05 = 17,500 3 ft x 5 ft Table 5 - Common steel deck types and dimensions1,3 Deck Type Common Thickness Table 6 - Steel deck gauge (GA) inch and millimeter equivalent2,3 Standard Dimensions 1.5" 6" 2.5" B 16-24 GA 1.75" 36" 6" 16-24 GA 1.5" BI 2.5" 3.5" 1.75" 36" 8" 16-22 GA 1.75" 24" 0.75" N 3" 2.75" 1.5" 6" 1.75" 18-22 GA 0.5" 36" 12" 1" Composite Deck 3" 7.25" Nominal Sheet Steel Thickness, t in. (mm) 16 0.0598 (1.52) 18 0.0474 (1.21) 20 0.0358 (0.91) 22 0.0295 (0.76) 24 0.0239 (0.61) 26 0.0179 (0.45) 28 0.0149 (0.38) 1 Dimensions shown are typical. However, the Structural Engineer should always consult with the steel deck manufacturer on the dimensions for the specific product as they can vary depending on the manufacturer. 2 Deck gauge inch equivalents taken from SDI Diaphragm Design Manual. Millimeter equivalents taken from CSSBI Design of Steel Deck Diaphragms. 3 Calculations to produce diaphragm shear tables with the deck profiles and gauges shown are possible with Hilti Profis DF Diaphragm software. 0.75" F Gauge (GA) 16-22 GA 36" 9/16" 4.75" Form Deck 24-28 GA 1.5" 1" 2.5" 30" 16 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 Steel Deck Fastening Systems Steel Deck Fastener Design and Selection 1.1 1.1.8 Diaphragm Shear and Stiffness Calculations Background: An extensive independent laboratory test program was conducted investigating the performance of steel deck diaphragms attached with Hilti fasteners. The program test scope consisted of full scale diaphragm system tests conducted in accordance with ICC-ES AC43, as well as comparative small element lap-joint shear tests conducted in accordance with AISI S905 Test Methods for Mechanically Fastened Cold-Formed Steel Connections. The resulting full scale and small element test data was analyzed and predictive equations were developed for the steel deck diaphragm system strength and stiffness using specific combinations of Hilti fasteners. For simplicity and familiarity, the Steel Deck Institute (SDI) Diaphragm Design Manual, 3rd Edition (DDM03) method equations are used as the basis for determining the steel deck diaphragm strength and stiffness. Specific Hilti fastener strength and stiffness values and test data correlation adjustment factors were developed to provide 95% or greater accuracy with test results per ICC-ES AC43 requirements. The resulting design information is documented in this section and in ICC-ES ESR-2776 (Hilti SLC), ESR-3592 and ESR-2197 (Hilti #10 HWH Screw). Design: Design equations for calculating steel deck diaphragm strength (S) and stiffness (G') or flexibility factor (F) with Hilti X-HSN 24, X-ENP-19 L15 or S-MD 12-24x1-5/8 M HWH5 frame fasteners and Hilti Sidelap Connectors (SLC) are provided. The equation numbers in parenthesis correspond to the equation numbers provided in the SDI DDM03. The design equation variables needed for common steel deck diaphragm applications are found in Tables 7 through 9. The conversion factors for Allowable Stress Design (ASD), Load Resistance Factor Design (LRFD) and Limit States Design (LSD) provided in Table 11 shall be applied to the values determined from the design equations in order to produce the final Allowable Diaphragm Shear, SASD or Factored Resistance Diaphragm Shear, SLRFD or SLSD, respectively. The calculated SASD, SLRFD or SLSD Diaphragm Shear values do not take into account steel deck buckling and must be checked against the appropriate buckling diaphragm shear value, Sbuckling, found in Table 12. Reference Sections 1.2, 1.3 and 1.4 for precalculated diaphragm shear and stiffness tables for the X-HSN 24, X-ENP-19 and S-MD 12-24x1-5/8 M HWH5 fasteners, respectively. The design equations and load values in this section are for 36" wide, 1-1/2" deep wide rib steel deck panels (B-Deck or BI-Deck types) and are limited to the fastener patterns shown in Figure 16 and sidelap connector spacings greater than 3" and in accordance with Table 10. For other steel deck diaphragm conditions (e.g. deck profile, deck gauge, concrete-filled, etc.) not represented in the tables found in this section, use Hilti Profis DF Diaphragm software or reference ICC-ES ESR-2197. Steel deck diaphragm strength design equations: S ne = Pn Qf , plf = (2 x α1 + 2 x α 2 + n e ) x < < S ni = {2 x A x (λ - 1) + B} x S = Q x nc f Qf , plf < N 2 x B2 , plf < x N2 + B2 2 (Eq. 2.2-2) (Eq. 2.2-4) (Eq. 2.2-5) Sn = least of Sne, Sni, and Snc, plf S = c x Sn , plf with: B = ns x α s + λ = 1- 1 x [ 2 x 2 x S ( xp2 ) + 4 S ( xe2 ) ] w2 1.5 x < v Q ≥ 0.7 α s = s 240 x t Qf where: t = nominal steel deck thickness, in. (Reference Table 6) w = deck width N = number of fasteners per unit length across the width, ft -1 xe = xp = distance from panel centerline to any fastener in a panel at the end (xe) or purlin (xp) supports S = nominal diaphragm shear strength, plf < v = span, ft < = panel length = 3 x < v, ft ne = ns = 3 x < v x 12 ÷ (sidelap connector spacing in inches) c = correlation factor for diaphragm system effect Reference Tables 7 and 8 for description and values of other variables for common conditions. Uplift and combined loading: Allowable loads to resist uplift forces are provided in the individual sections for each frame fastener. Reference SDI DDM03 Section 4.10 for combined tension uplift and diaphragm shear interaction. Uplift and combined loading calculations are shown in the Example Problem at the end of this section on pages 22 and 23. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 17 Steel Deck Fastening Systems 1.1 Steel Deck Fastener Design and Selection Steel deck diaphragm stiffness and flexibility factor design equations: Ext G' = 3.78 + 0.9 x Dn + C , kips/in. F= With: (Eq. 3.3-3) 1000 , micro-inches/lb G' ( 1 t C = 29,500 x x S x S f α1 + α 2 + ns x f w Ss D Dn = < x 12 ) x < x 12 (Eq. 3.3-1) (Eq. 3.3-2) Reference Tables 7 and 9 for description and values of other variables for common conditions. E = modulus of elasticity for steel = 29,500 ksi Table 7 – Diaphragm strength (S) and stiffness factor (G') equation variable values D-Warping constant, in. Deck type Fastener pattern α1 – end distribution factor α2 – purlin distribution factor Sxe2, in.2 Sxp2, in.2 A N, ft-1 22 GA 20 GA 18 GA 16 GA 1-1/2" Wide Rib BDeck or BIDeck 36/11 36/9 36/7 36/5 36/4 36/3 3.667 3.000 2.000 1.667 1.333 1.000 3.667 3.000 2.000 1.667 1.333 1.000 1944 1656 1008 936 720 648 1944 1656 1008 936 720 648 2 2 1 1 1 1 3.000 2.333 2.000 1.333 1.000 0.667 1548 1548 1548 9096 12864 26508 1164 1164 1164 6804 9624 19824 756 756 756 4464 6312 13008 540 540 540 3144 4452 9180 Table 8 – Diaphragm strength (S) equation variable values Configuration Min. deck Deck tensile (yield) type strength, ksi 45 (33) B 92 (80) BI B or BI 45 (33) 45 or 92 (33 or 80) Frame fastener base material thickness, in. Sidelap connector1,2 X-HSN 24 1/8 ≤ tf < 3/16 Hilti SLC X-HSN 24 3/16 ≤ tf ≤ 3/8 Hilti SLC X-ENP-19 tf ≥ 1/4 Hilti SLC S-MD 12-24x1-5/8 M HWH5 0.0598 ≤ tf ≤ 1/4 Hilti SLC X-HSN 24 1/8 ≤ tf < 3/16 Hilti SLC X-HSN 24 3/16 ≤ tf ≤ 3/8 Hilti SLC X-ENP-19 tf ≥ 1/4 Hilti SLC S-MD 12-24x1-5/8 M HWH5 0.0598 ≤ tf ≤ 1/4 Hilti SLC X-HSN 24 1/8 ≤ tf < 3/16 Hilti SLC X-HSN 24 3/16 ≤ tf ≤ 3/8 Hilti SLC S-MD 12-24x1-5/8 M HWH5 0.0598 ≤ tf ≤ 1/4 Hilti SLC X-HSN 24 1/8 ≤ tf ≤ 3/8 Hilti #10 HWH Screw X-ENP-19 tf ≥ 1/4 Hilti #10 HWH Screw S-MD 12-24x1-5/8 M HWH5 0.0598 ≤ tf ≤ 1/4 Hilti #10 HWH Screw 22 (0.0295) Qf, lb Qs, lb Correlation factor, c 1357 844 1.155 1590 844 1.121 1597 844 1.257 1193 717 1.000 1357 844 1.155 1941 954 1.052 1964 954 1.197 1193 717 1.000 1357 844 1.155 1516 882 1.284 1193 717 1.000 1489 633 1.000 1603 633 1.000 1193 633 1.000 Deck gauge (inches) 20 18 (0.0358) (0.0474) Qf, lb Qs, lb Qf, lb Qs, lb Correlation Correlation factor, c factor, c 1824 1260 1865 1701 1.172 1.203 2107 1260 2663 1701 1.102 1.066 2112 1260 2764 1701 1.205 1.106 1661 870 1860 1152 1.000 1.000 1824 1260 1865 1701 1.172 1.203 2208 1341 2698 1859 1.054 1.058 2165 1341 3022 1859 1.166 1.108 1661 870 1860 1152 1.000 1.000 1712 1111 1865 1591 1.172 1.203 1712 1111 2450 1591 1.233 1.140 1661 870 1860 1152 1.000 1.000 1795 769 2348 1018 1.000 1.000 1933 769 2529 1018 1.000 1.000 1661 769 1860 1018 1.000 1.000 16 (0.0598) Qf, lb Qs, lb Correlation factor, c – – – 3035 2024 1.028 3079 2024 1.000 1860 1453 1.000 – – – 3095 2343 1.062 3577 2343 1.046 1860 1453 1.000 – – – 2553 2051 1.040 1860 1453 1.000 2924 1284 1.000 3149 1284 1.000 1860 1284 1.000 1 Sidelap connector spacing must meet the requirements of Table 10. 2 Reference Table 3 and Section 1.5 for more information on the proper selection of Hilti Sidelap Connectors (SLC). 18 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 Steel Deck Fastening Systems Steel Deck Fastener Design and Selection 1.1 Table 9 – Diaphragm stiffness (G') and flexibility factor (F) equation variable values Deck gauge (inches) Configuration Deck type B or BI Min. deck tensile (yield) strength, ksi Frame fastener Sidelap connector1 X-HSN 24 Hilti SLC or Hilti #10 HWH Screw X-ENP-19 Hilti SLC or Hilti #10 HWH Screw S-MD 12-24x1-5/8 M HWH5 Hilti SLC or Hilti #10 HWH Screw 45 or 92 (33 or 80) 22 (0.0295) 20 (0.0358) 18 (0.0474) 16 (0.0598) Sf, in./kip Sf, in./kip Sf, in./kip Sf, in./kip Ss, in./kip Ss, in./kip Ss, in./kip Ss, in./kip 0.0073 0.0175 0.0044 0.0175 0.0076 0.0175 0.0066 0.0159 0.0040 0.0159 0.0069 0.0159 0.0057 0.0138 0.0034 0.0138 0.0060 0.0138 0.0051 0.0123 0.0030 0.0123 0.0053 0.0123 1 Reference Table 3 and Section 3.5.4 for more information on the proper selection of Hilti Sidelap Connectors (SLC). Table 10 – Minimum recommended sidelap connector spacing (Inches center-to-center) for X-HSN 24 and X-ENP-19 powder-actuated fasteners with B-Deck or BI-Deck type Frame fastener base material thickness, in. X-HSN 24 1/8 ≤ tf < 3/16 X-HSN 24 3/16 ≤ tf ≤ 3/8 X-ENP-19 tf ≥ 1/4 Deck gauge 22 20 18 16 22 20 18 16 22 20 18 16 Frame fastener pattern 36/3 36/4 SLC1 #10 – – ≥ 12 ≥3 – – ≥6 ≥3 36/7 SLC1 #10 36/92 SLC1 #10 36/112 SLC1 #10 SLC1 #10 36/5 SLC1 #10 ≥ 12 ≥6 ≥ 12 ≥6 ≥6 ≥3 ≥6 ≥3 ≥6 ≥3 – – – – – – – – – – ≥6 ≥3 ≥6 ≥3 ≥3 ≥3 ≥3 ≥3 ≥3 ≥3 ≥6 ≥3 ≥6 ≥3 ≥3 ≥3 ≥3 ≥3 ≥3 ≥3 1 Hilti SLC spacings less than those tabulated may be used. The tabulated spacing should be used in the calculation of diaphragm shear strength when using the Qf, Qs and c values from Table 8. Alternatively, only when the SLC spacings are less than those tabulated, the Qf, Qs and c values found in Table 8 can be replaced by the following values. X-HSN 24 – All deck types, strengths and base steel thicknesses listed in Table 8 22 Gauge (0.0295 in.)- Qf = 1489 lb, Qs = 716 lb, c = 1.000 20 Gauge (0.0358 in.)- Qf = 1795 lb, Qs = 869 lb, c = 1.000 18 Gauge (0.0474 in.)- Qf = 2348 lb, Qs = 1151 lb, c = 1.000 16 Gauge (0.0598 in.) - Qf = 2924 lb, Qs = 1452 lb, c = 1.000 2 For 36/9 and 36/11 patterns, when wind (or seismic) diaphragm shear capacities exceed the values shown below, the fastening pattern must be increased at the building perimeter, chords, collectors or other shear transfer elements to two fasteners per rib (i.e. 36/14 pattern). The wind (or seismic) diaphragm shear capacity must not be greater than that determined from the 36/9 and 36/11 patterns, as applicable. X-HSN 24 with steel support framing thicknesses 1/8" ≤ tf < 3/16" ASD wind (seismic) LRFD wind (seismic) 22 Gauge (0.0295 in.) - 1275 plf (1200 plf) 2100 plf (1950 plf) 20 Gauge (0.0358 in.) - 1600 plf (1500 plf) 2625 plf (2450 plf) 18 Gauge (0.0474 in.) - 1825 plf (1700 plf) 3000 plf (2675 plf) LSD wind (seismic) 28.5 N/mm (26.3 N/mm) 35.8 N/mm (32.8 N/mm) 39.0 N/mm (37.2 N/mm) X-HSN 24 with steel support framing thicknesses 3/16" ≤ tf ≤ 3/8" ASD wind (seismic) LRFD wind (seismic) 22 Gauge (0.0295 in.) - 1400 plf (1300 plf) 2300 plf (2125 plf) 20 Gauge (0.0358 in.) - 1700 plf (1600 plf) 2800 plf (2600 plf) 18 Gauge (0.0474 in.) - 2250 plf (2100 plf) 3700 plf (3425 plf) 16 Gauge (0.0598 in.) - 2775 plf (2600 plf) 4550 plf (4225 plf) LSD wind (seismic) 31.0 N/mm (28.8 N/mm) 37.9 N/mm (35.0 N/mm) 50.0 N/mm (46.3 N/mm) 61.7 N/mm (56.9 N/mm) Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 19 Steel Deck Fastening Systems 1.1 Steel Deck Fastener Design and Selection Table 11 – Conversion factors for Allowable Stress Design (ASD), Load Resistance Factor Design (LRFD) and Limit States Design (LSD) Design method ASD LRFD LSD For Multiply calculated diaphragm shear strength by1,2 Diaphragms mechanically connected to the structure subjected to earthquake loads or load combinations which include earthquake loads 0.400 Diaphragms mechanically connected to the structure subjected to wind loads or load combinations which include wind loads 0.426 Diaphragms mechanically connected to the structure subject to all other load combinations 0.400 Diaphragms mechanically connected to the structure subjected to earthquake loads or load combinations which include earthquake loads 0.650 Diaphragms mechanically connected to the structure subjected to wind loads or load combinations which include wind loads 0.700 Diaphragms mechanically connected to the structure subject to all other load combinations 0.650 Diaphragms mechanically connected to the structure subjected to earthquake loads or load combinations which include earthquake loads 0.600 Diaphragms mechanically connected to the structure subjected to wind loads or load combinations which include wind loads 0.650 Diaphragms mechanically connected to the structure subject to all other load combinations 0.600 1 Conversion factors determined from Table D5, of AISI S100. 2 Diaphragm capacities should be limited to the respective ASD, LRFD and LSD buckling diaphragm shear capacities found in Table 12. Table 12- ASD and LRFD diaphragm shears (plf) and LSD diaphragm shears (N/mm) for buckling, Sbuckling1,2 Steel Deck type Deck gauge Standard 1-1/2inch deep flutes, 6-inches centerto-center 22 20 18 16 Standard 1-1/2inch deep flutes, 6-inches centerto-center 22 20 18 16 Steel deck type Standard 1-1/2inch deep flutes, 6-inches centerto-center Moment of inertia, I mm4/mm 3'-0" 0.152 0.198 0.284 0.355 8444 11000 15778 19720 4750 6188 8875 11094 13511 17600 25244 31556 7600 9900 14200 17750 0.152 0.198 0.284 0.355 Moment of Deck inertia, I gauge mm4/mm 22 20 18 16 208 270 388 485 Span, <v (ft-in.) 4'-0" 5'-0" 6'-0" ASD (plf) 3040 2111 3960 2750 5680 3944 7100 4931 LRFD (plf) 4864 3378 6336 4400 9088 6311 11360 7889 7'-0" 8'-0" 9'-0" 10'-0" 11'-0" 12'-0" 1551 2020 2898 3622 1188 1547 2219 2773 938 1222 1753 2191 760 990 1420 1775 628 818 1174 1467 528 688 986 1233 2482 3233 4637 5796 1900 2475 3550 4438 1501 1956 2805 3506 1216 1584 2272 2840 1005 1309 1878 2347 844 1100 1578 1972 Span, <v (mm) 900 192.6 250.0 359.3 449.1 1200 1500 1800 2100 2400 2700 3000 3300 3600 108.3 140.6 202.1 252.6 LSD (N/mm) 69.3 48.1 90.0 62.5 129.3 89.8 161.7 112.3 35.4 45.9 66.0 82.5 27.1 35.2 50.5 63.2 21.4 27.8 39.9 49.9 17.3 22.5 32.3 40.4 14.3 18.6 26.7 33.4 12.0 15.6 22.5 28.1 1 Load values based upon a safety factor (Ω) of 2.00 for ASD, a phi factor (Φ) of 0.80 for LRFD or a phi factor (Φ) of 0.75 for LSD. 2 Diaphragm shears in this table are for steel deck buckling failure mode only and are to be used as prescribed in Section 1.1.8. If design condition is not tabulated, diaphragm shears for buckling may be calculated using the following equations: For ASD, Sbuckling = (I x 106/(< v)2) / 2.0 , plf For LRFD, Sbuckling = (I x 106/(< v)2) x 0.8 , plf For LSD, Sbuckling = (I x 106/(< v)2) x 0.75 , N/mm 20 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 Steel Deck Fastening Systems Steel Deck Fastener Design and Selection 1.1 Pattern 36/3 Pattern 36/4 Pattern 36/5 Pattern 36/7 Pattern 36/9 Pattern 36/11 Note 1: Nestable B-Deck shown. Interlocking BI-Deck with screwable sidelap is also covered by the equations discussed in Section 1.1.8. Note 2: Bar joist shown. Connection to structural steel members also covered by the equations discussed in Section 1.1.8. Figure 16: Common frame fastener patterns Refer to Note 2" min. Hilti Fastener Note: Some patterns may require two fasteners in one flute. Fasteners may be installed on either side of the structural steel beam or bar joist. 17a.Frame fastener attachment of steel deck to frame 17c. Sidelap connector with B-Deck 17b. Steel deck endlap condition 17d. Sidelap connector with screwable BI-Deck Figure 17: Typical frame, endlap and sidelap connections Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 21 Steel Deck Fastening Systems 1.1 Steel Deck Fastener Design and Selection Example problem Design parameters: Design problem: Load type: Wind Design method: ASD Span: 6'-0" Deck: 20 GA. 1-1/2" B-Deck (fu ≥ 45 ksi) Base steel: Bar joist with 1/4" top chord Frame fastener pattern: 36/7 Sidelap fastener spacing: 12" O.C. Frame fastener: X-HSN 24 Sidelap fastener: Hilti SLC Required diaphragm shear (Q): 650 plf Required uplift (T): 35 psf Determine allowable diaphragm shear strength (SASD), uplift (Tn (ASD)) and stiffness (G') for the given steel deck diaphragm and check against required loads. 6" 36" Hilti SLC 1-1/2" X-HSN 24 Calculation steps Step 1: Calculate nominal diaphragm shear strength limited by edge fasteners: This calculation is not required when the number of edge connectors (ne) equals the number of sidelap fasteners (ns). In these cases, Sne does not limit diaphragm shear strength. Step 2: Calculate nominal diaphragm shear strength limited by interior panel fasteners: Q 2107 S ni = {2 x A x (λ- 1) + B} x f = {2 x 1 x (0.802 - 1) + 16.99} x = 1,942 plf < 18 with: 1.5 x < v 1.5 x 6 λ = 1= 1 = 0.802 ≥ 0.7 240 x t 240 x 0.0358 1 [2 x 2 x 1008 + 4 x 1008] B = ns x α s + x [ 2 x 2 x S ( xp2 ) + 4 S ( xe2 ) ] = 18 x 0.598 + = 16.99 2 w 362 where: 3 x < v x 12 3 x 6 x 12 ns = ne = = = 18 Sidelap Spacing 12 αs = SDI DDM03 Ref. HNA Technical Guide Eq. 2.2-2 Sec. 1.1.8 Eq. 2.2.3 Sec. 1.1.8 and Tables 7 and 8 Eq. 2.2-5 Sec. 1.1.8 and Tables 7 and 8 Qs 1260 = = 0.598 2107 Qf Step 3: Calculate nominal diaphragm shear strength limited by corner fasteners: S nc = Q f x N xB = 2107 x <2 x N 2 + B 2 2 2 2.00 x 16.99 = 1,798 plf 182 x 2.002 + 16.992 2 2 Step 4: Apply correlation factor, c, to determine correlated nominal diaphragm shear strength S = c x Sn = 1.102 x 1,798 = 1,981 plf where: Sn = least of Sne, Sni and Snc = Snc = 1,798 plf Step 5: Apply appropriate conversion factor to determine allowable diaphragm strength SASD (wind) = S x Conversion Factor = 1,981 x 0.426 = 844 plf Step 6: Check to see if steel deck buckling controls Sbuckling (ASD) = 2,750 plf > SASD (wind) therefore, SASD (wind) = 844 plf ≥ 650 plf Sec. 1.1.8 and Table 8 Sec. 2.4 Table 11 Table 12 22 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 Steel Deck Fastening Systems Steel Deck Fastener Design and Selection 1.1 Calculation steps SDI DDM03 Ref. HNA Technical Guide Eq. 3.3-3 Sec. 1.1.8 and Tables 7 and 9 Roof Deck Const. Handbook Sec. 1.2.3 Step 7: Calculate diaphragm stiffness: Ext 29,500 x 0.0358 G' = = = 86 kips/in. 3.78 + 0.9 x Dn + C 3.78 + 0.9 x 5.39 + 3.65 1000 1000 = = 11.6 micro-inches/lb G' 85.99 where: D 1164 Dn = = = 5.39 < x 12 18 x 12 1 t x Sf C =Ex x α + α + n x Sf x < x 12 w 1 2 s Ss 1 0.0358 x 0.0066 C = 29,500 x x 2 + 2 + 18 x 0.0066 36 0.0159 F= ( ( ) ) x 18 x 12 = 3.65 Step 8: Calculate nominal uplift resistance: K x Tn,f 6.00 x 1,680 Tn = = = 560 psf 3x6 C x <v Where: K = Number of frame fasteners per deck sheet per joist/beam = 6.00 C = Width of deck sheet = 3 feet Tn,F = Controlling ultimate tension capacity of frame fastener = 560 lb x 3.0 = 1,680 lb Step 9: Apply uplift safety factor to determine allowable uplift resistance: Tn 560 Tn (ASD) = = = 187 psf ≥ 35 psf 3.00 Ω UP Step 10: Check combined loading: ΩxQ Ω xT 0.85 x ( ) + ( UP ) ≤ 1.0 S Tn 0.85 x ( Sec. 4.10 2.35 x 650 3.00 x 35 ) + ( ) ≤ 1.0 0.843 ≤ 1.0 1981 560 Note: The Hilti Profis DF Diaphragm software provides full calculations for diaphragm shear and stiffness when desired. Hilti is a leading manufacturer of direct fastening systems for steel and metal applications. As a member of the Steel Deck Institute (SDI), Hilti participates in and supports steel deck industry research at leading universities and test labs. Recent research projects with Hilti direct fastening systems have included inelastic seismic deck diaphragms and deep deck / cellular deck diaphragms. Diaphragm data is calculated in accordance with SDI Diaphragm Design equations using specific Hilti fastener strength and stiffness values with data correlation adjustment factors in accordance with ICC-ES AC43 requirements. Independent tests are the best guide to product performance and reliability, a philosophy to which Hilti and the SDI subscribe. The support for ongoing research programs is indicated by the number and scope of tests already performed and by the policy of sponsoring new tests when new products or applications are introduced. Hilti provides direct fastening system performance data, ICC-ES Evaluation Service Reports, design software, fire ratings and load test results for Hilti direct fastening systems used in steel deck applications. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 23 36/3 6'' Steel Deck Fastening Systems 914/3 36'' 152 mm 1-1/2'' 914 mm 38 mm 1.1 Steel Deck Fastener Design and Selection EDN IMPERIAL EDN 1.1.9 How to use Diaphragm Shear Tables 36/4 General: The following Product Technical Guide Sections 1.2 to 1.6 provide Hilti fastener product6''technical data sheets and 36'' 1-1/2''the pre-calculated diaphragm shear and stiffness tables using design equations provided in Section 1.1.8. Pre-calculated diaphragm shear and stiffness tables are provided in two formats. 36/5 Tables in Sections 1.2, 1.3 and 1.4 are in a traditional design format with diaphragm shear and stiffness values within 6'' 36'' 1-1/2'' the table. Tables in Section 1.6 are in a Hilti alternative format with cost optimized Hilti frame fastener patterns, Hilti sidelap connector (SLC) spacings and deck gauge for a given diaphragm shear 36/7 load demand. This alternative format provides a means for quick reference in order to determine cost optimized 6'' 36'' 1-1/2'' equivalent fastening solutions based on diaphragm shear load only. Steel Deck Fastening Systems 36/3 914/4 Traditional diaphragm shear tables: Sections 1.2, 1.3 and 1.4 provide tables in 152 a format similar to those published in 6'' mm 36'' 914 mm 38 mm the SDI DDM03, CSSBI and most1-1/2'' steel deck manufacturers' catalogs. As shown in Figure 18, these diaphragm shear tables are generally created with span across the heading and sidelap 36/4 spacing along the left margin or914/5 column. Along with other design variables asmm deck gauge and fastener pattern, the 6'' such 152 36'' 1-1/2'' 914 mm 38 mm tables are populated with the corresponding diaphragm shear and stiffness values. 152 mm 152 mm The Structural Engineer searches through the various combinations until a diaphragm shear and stiffness factor is 36/5 914/7 found that meet the design requirements. 6'' 152 mm Optimized diaphragm shear tables: 36'' 1-1/2'' 914 mmSection 1.6 38provides mm tables in an alternative format that helps a Structural Engineer to quickly select a cost optimized Hilti frame fastener pattern, Hilti In all cases, diaphragm shear values determined using either 1.2 Deck Fasteners for Attachment tosidelap Bar connector Joist (SLC) spacing and deck gauge combination to satisfy the diaphragm shear load requirement table format are consistent. 36/7 36/9 914/9 found in the left column of the table (Reference Figure 19). These tables do not take into account other design factors, 6'' based These tables are on diaphragm shear capacity only, 6'' 152 mm 36'' 1-1/2'' such as gravity or wind uplift loads. These requirements 36'' 1-1/2'' 914 mm 38 mm diaphragm stiffness must beG',verified Allowable Stress Design (ASD) - AllowableEngineer. Diaphragm Shears, SASD, (plf) and Stiffness Factors, (kips/in.)separately. for should be checked separately by the Structural 152 mm 152 mm Standard 1-1/2" Deep Flutes, 6" Center-to-Center Steel Deck (Fy ≥ 33 ksi; Fu ≥ 45 ksi) Installed with Hilti X-EDN19 or X-EDNK22 Fasteners with 36/9 or 36/7 End and Interior Support Fastener Patterns1,2,3,4 Gage Sidelap Spacing Hilti SLC5,6 36" o.c. 24" o.c. 22 18" o.c. 12" o.c. 6" o.c. 36" o.c. 24" o.c. 20 18" o.c. Span (ft - in.) 6'-0" 7'-0" 8'-0" 9'-0" 10'-0" Fasteners Per Sheet To Support 36/9 36/11 914/11 9 7 9 7 9 7 9 7 9 7 9 7 9 7 SASD 715 499 612 431 529 378 467 341 421 313 388 292 363 277 6'' 152 mm 6'' G' 51.9 48.5 56.4 52.0 59.2 54.1 60.9 55.4 62.1 62.5 56.5 62.9 56.5 36'' 56.2 1-1/2'' 714 mm 36'' 38 mm 1-1/2'' SASD 765 554 666 489 596 444 534 408 488 380 455 360 430 344 G' 52.9 50.2 58.1 54.5 61.6 57.5 64.1 59.6 65.8 61.0 67.1 62.1 68.0 62.9 SASD 813 607 719 545 651 501 601 469 555 445 522 426 497 410 G' 53.8 51.5 59.5 56.5 63.7 60.2 66.7 62.9 69.0 64.9 70.9 66.7 71.9 68.0 SASD 903 706 817 649 755 610 708 580 672 558 643 540 620 526 G' 55.2 53.5 61.7 59.6 66.7 64.3 70.7 68.1 74.1 70.9 76.3 73.5 78.7 75.8 SASD 1123 941 1060 902 1014 874 980 853 952 837 931 824 760 760 36/11 G' 57.9 57.0 65.8 64.8 72.3 71.2 77.7 76.5 82.6 81.3 86.2 84.7 90.1 88.5 SASD 948 668 815 581 715 517 635 468 575 432 528 403 495 383 G' 71.9 66.1 75.9 68.9 77.9 70.1 78.7 70.4 6'' 78.8 70.3 78.7 69.9 78.1 69.4 36'' 530 1-1/2'' 1021 749 894 665 804 607 734 564 673 627 502 593 481 SASD G' 73.7 68.8 78.7 72.9 81.7 75.3 83.5 76.7 84.5 77.5 84.7 78.1 85.5 78.1 Steel Deck Fastening Systems SASD 1090 825 970 745 883 690 819 649 769 618 725 594 692 574 G' 75.2 70.9 81.3 76.3 84.7 79.4 87.7 82.0 89.3 83.3 90.9 84.7 91.7 85.5 SASD 1218 964 1110 894 1032 844 973 808 927 779 891 757 861 739 G' 77.7 74.6 84.8 81.2 90.0 86.1 93.9 89.7 96.8 92.6 99.0 95.2 101.0 97.1 SASD 1522 1288 1447 1241 1392 1183 1317 1164 1222 1149 990 990 Span =1208 4'-0'' 1350 G' 82.5 80.9 91.9 90.2 99.4 97.5 105.4 103.4 110.4 108.4 114.9 112.4 117.6 116.3 Recommended Hilti Powder-Actuated Frame Fastener Pattern - Sidelap Spacing Hilti SLC (in. o.c.)* SASD 1171 831 1010 724 895 651 800 593 726 548 669 513 623 485 24* with 3/16" ≤107.3 tf ≤ 3/8" 93.8 X-HSN with 1/8"103.1 ≤ tf < 3/16" with G' 109.9 X-ENP-19 99.0 111.5tf ≥ 1/4" 98.7 110.9 97.4X-HSN 109.3 95.7 105.2 24* 91.7 90.1 SASD 1266 935 1112 833 1003 763 921 712 855 672 798 641 752 614 20 ga. 116.818 ga. 16 ga. 106.3 22 ga.117.5 20 ga. 18 ga.105.3 22115.5 ga. 20 ga. 114.9 18 103.1 ga. G' 22 ga. 113.6 104.2 105.9 117.7 106.0 116.6 104.4 Factor 4'-0" 5'-0" Figure 18: Excerpt of traditional diaphragm shear and stiffness factor table 12" o.c. 6" o.c. Allowable Diaphragm Design 36" o.c. Strength, plf* SASD 24" o.c. SASD (seismic) (wind) Optimized Diaphragm Shear Tables 1.5 SASD36/3 -48 1355 36/3 1033 937 1106 1028 36/4 821 968 754 289 -48 1210 36/3 -48 36/3 -48 870 36/3 -48 -48 36/4 -48784 36/4920 -48 36/4 -48 881 36/4 730 -48 18272 18" o.c. G'36/3 -48 117.6 36/3 108.7 112.4 36/3 123.5 125.0 36/4 114.9 114.9 36/4 125.0 114.9 291 309 -48 122.0 36/3 -48 -48 113.6 36/3 -30 -48 125.0 36/4 -48 -48 36/4 -48123.536/4114.9 -48 311 331 -48 1390 36/3 -48 -48 1068 36/3 -24 -48 1171 36/4 -48991 36/4 -36 36/4 -48109236/4 942 -48 SASD36/3 -42 1519 36/3 1211 1127 36/3 1296 1226 36/4 1024 1128 964 12" o.c. 333 354 -48 128.9 36/3 -48 -48 125.7 36/3 -18 -48 137.6 36/4 -48 -24 36/4 -48138.936/4133.3 -48 G'36/3 -30 122.0 36/3 116.3 121.7 36/3 133.1 135.8 36/4 128.3 130.2 36/4 138.8 131.6 356 379 36/3 -24 36/3 -48 36/3 -48 36/3 -48 36/4 -30 36/4 -48 36/4 -48 36/4 -20 36/4 -48 36/4 -48 SASD 1519 1211 1390 1145 1296 1106 1243 1077 1205 1054 1175 1037 1150 1022 6" o.c.406 381 36/3 -18 36/3 -48 36/3 -48 36/3 -48 36/4 -24 36/4 -48 36/4 -48 36/4 -18 36/4 -48 36/4 -48 G' 133.3 129.9 143.6 139.9 151.5 147.6 157.5 153.6 162.2 158.4 166.0 162.4 169.5 166.7 408 434 36/3 -14 36/3 -42 36/3 -48 36/3 -48 36/4 -18 36/4 -48 36/4 -48 36/4 -14 36/4 -48 36/4 -48 437 464 shear36/4 -20are for36/3 -30 36/3 -48deck to 36/3 -48 36/4 -14 ranging 36/4 -42 36/4to-48 36/4 -12 36/4 -36 36/4 -48 1 Tabulated diaphragm values attachment of steel base steel thicknesses from 3/16" 3/8". For attachment to base 467thicknesses 497 -18 36/3 shear -20 values 36/3for -48 36/3 -48 fasteners 36/4 should -12 36/4 -30 -48 36/5 -16 36/4 -24 36/4 -42 steel less than 36/4 3/16", diaphragm the X-EDNK22 be calculated in36/4 accordance with Section 1.1.8 of 500 532 36/4 -14 36/3 -18 36/3 -36 36/3 -42 36/5 -18 36/4 -24 36/4 -48 36/5 -14 36/4 -20 36/4 -36 this Product Technical Guide Supplement. 36/4 -18 36/4 -24 535 569 36/4 -12 36/4 -24 36/3 -24 36/3 -30 36/5 -14 36/4 -20 36/4 -42 36/9 -48 2 Tabulated ASD diaphragm shear loads are calculated with a safety factor (Ω) of 2.35 for wind loads. To calculate ASD values for load combinations 572 609 36/5 -16 36/4 -20 36/3 -20 36/3 -24 36/5 -12 36/4 -16 36/4 -30 36/9 -48 36/4 -14 36/4 -20 involving earthquake, multiply values in table by 2.35 and divide by a safety factor (Ω) of 2.50. Panel buckling has been checked. 612 651 36/5 -14 36/4 -18 36/3 -16 36/3 -18 36/9 -48 36/4 -14 36/4 -24 36/9 -30 36/4 -12 36/4 -18 3 At 655 diaphragm perimeter, Hilti frame fasteners should be spaced at identical spacing as sidelap connectors. 697 36/5 -10 36/4 -14 36/4 -24 36/3 -14 36/5 -8 36/5 -20 36/4 -20 36/9 -20 36/5 -18 36/4 -14 4 Interpolation of diaphragm shear strengths and stiffness factors between36/9 span dimensions, sidelap 36/4 spacings deck-16 gauge. 36/5 -14 701 746 36/5 -8 36/4 -12 36/4 -20 is allowed 36/4 -24 -24 36/5 -16 -18 and36/9 36/4 -12 750 798 36/5 36/5 36/4 -18 36/4 diaphragm -18 36/9 -18 strengths 36/5 -12 36/5 factors -24 36/9 -12 36/5 -12 36/5 -18 Alternatively, use calculations as -7 discussed in-16 Section 1.1.8 to determine shear and stiffness directly. 36/9 -24 36/5 -14per span 36/4(SPS), -14 use36/4 -16 36/9 -14 SPS=((span, 36/9 -48 ft) x 12)/(SS, 36/5 -20in.). Round 36/9 -10 36/9 -42 36/5 -14 5 To802 convert from854 sidelap spacing (SS) to sidelaps the following formula: up to the next 859 914 36/9 -18 36/5 -10 36/5 -20 36/4 -12 36/9 -10 36/9 -42 36/9 -48 36/9 -8 36/9 -30 36/5 -12 whole sidelap connector. 919 977 36/9 -12 36/5 -8 36/5 -16 36/5 -18 36/9 -8 36/9 -24 36/7 -20 36/9 -7 36/9 -20 36/7 -16 6 For 18 gauge deck use S-SLC 02 M HWH. More information on Hilti Sidelap Connectors (SLC) can be found in Section 1.4. 983 36/9 -10 -7 36/5 -14 36/5 -14 -7 36/9 -20 36/9 -48 36/11-8 36/9 -16 -24 24 Hilti, Inc. (US) 1-800-879-8000 |1046 www.us.hilti.com I 36/5 en español 1-800-879-5000 I Hilti36/9 (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG36/9 Decking Supplement 2014 1052 1119 36/9 -8 36/5 -6 36/5 -10 36/5 -12 36/9 -6 36/9 -16 36/9 -48 36/11-7 36/9 -12 36/9 -20 1126 1197 36/9 -7 36/9 -16 36/5 -8 36/5 -10 36/11-7 36/9 -12 36/9 -30 36/11-6 36/9 -10 36/7 -10 1204 1281 36/9 -5 36/9 -12 36/5 -7 36/5 -8 36/11-6 36/9 -10 36/9 -20 36/9 -8 36/9 -12 Figure 19: Excerpt of optimized diaphragm shear table 152 mm 9 152 mm Steel Deck Fastening Systems X-HSN 24 for Fastening Deck to Bar Joist 1.2 1.2.1 Product Description The Hilti bar joist deck fastening system consists of powder-actuated tools that are primarily used with the X-HSN 24 fasteners, which are available in a collated version. For many bar joist decking projects, the tool of choice is the DX 860-HSN tool. This self-contained stand up decking tool is powered by 0.27 caliber short cartridges, which are loaded into the tool in strips of 40. The cartridges drive the X-HSN 24 fasteners into almost any type of steel deck profile and base steel thicknesses of 1/8" to 3/8". These fasteners are available in collated strips of 10. Four of these strips are loaded into the DX 860-HSN tool, along with the cartridge strip, and enable the operator to fasten at a rate of up to 1,000 quality fastenings per hour. Additionally, this tool offers punch through resistance in cases where the base material is inadvertently missed. Fastener plating 5 µm Zinc1 Nominal fastener hardness 55.5 HRC 1.2.3 Technical Data Allowable pullout loads for attachments to steel base material lb (kN)1, 2, 3 X-HSN 24 Material Specifications 1.2.3 Technical Data 1.2.4 Ordering Information X-HSN 24 Approvals/Listings Fastener material Carbon Steel 1/8 435 (1.95) 1.2.2 Hilti X-HSN 24 steel deck fasteners comply with ANSI/SDI RD1.0, C1.0 and NC1.0 standards. 1 ASTM B633, SC 1, Type III. Reference Section 2.3.3.1 of Hilti North American Product Technical Guide Volume 1: Direct Fastening for more information. Fastener Product Description Other tools include the hand held DX 460-SM, a semi-automatic magazine tool for use on smaller jobs or in tandem with the DX 860-HSN. 1.2.2 Material Specifications Fastener designation X-HSN 24 1.2.1 Base material thickness (in.) 3/16 1/4 635 (2.82) 750 (3.34) ICC-ES (International Code Council) ESR-3592, ESR-2776, ESR-2197, ESR-1116, ESR-1735P, ESR-1414, ESR-2408 COLA (City of Los Angeles) RR 25974, RR 25877, RR 25296 FM (Factory Mutual) For attaching Class 1 Steel Roof Decks with 1-60 and 1-90 wind uplift ratings. Refer to FM RoofNav for specific assembly listings. UL (Underwriters Laboratories) Fasteners for attaching steel roof deck (uplift and fire classification) 3/8 750 (3.34) 1 These values represent testing performed in ASTM A36 plate steel. 2 The values must be compared with allowable tensile pullover values. 3 Allowable values based on safety factor of 5.0. Allowable pullover and shear bearing loads for attaching steel deck1,2,3 Fastener X-HSN 241 16 (0.0598) Tension Shear lb (kN) lb (kN) 18 (0.0474) Tension Shear lb (kN) lb (kN) Steel deck gauge (in.) 20 (0.0358) 22 (0.0295) Tension Shear Tension Shear lb (kN) lb (kN) lb (kN) lb (kN) 24 (0.0239) Tension Shear lb (kN) lb (kN) 26 (0.0179) Tension Shear lb (kN) lb (kN) 865 975 725 785 560 600 500 500 450 410 415 310 (3.85) (4.29) (3.22) (3.45) (2.49) (2.64) (2.22) (2.20) (2.00) (1.80) (1.85) (1.36) 1 For base steel thickness 1/8" (3 mm) to 3/8" (10 mm). 2 Allowable values are based on a safety factor of 3.0. 3 Loads based on ASTM A1008, or minimum ASTM A653 SQ33 steel deck. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 25 6'' 36'' 1-1/2'' 6'' 36'' 152 mm 1-1/2'' 914 mm 38 mm Steel Deck Fastening Systems 1.2 X-HSN 24 for Fastening Deck to Bar Joist 36/7 36/9 6'' 36'' 1-1/2'' 6'' 36'' 914/9 152 mm 1-1/2'' 914 mm 38 mm Allowable Stress Design (ASD) - Allowable diaphragm shears, SASD, (plf) and stiffness factors, G', (kips/in.) for standard 1-1/2" deep flutes, 6" center-to-center steel deck (Fy ≥ 33 ksi; Fu ≥ 45 ksi) installed with Hilti X-HSN 24 fasteners with 36/9 or 36/7 end and interior support fastener patterns1,2,3,4,5 Gauge Sidelap spacing Hilti SLC6,7,8 36" O.C. 24" O.C. 18" O.C. 22 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 20 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 18 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 16 12" O.C. 6" O.C. 3" O.C. 4'-0" Factor 36/11 SASD 6'' G' SASD G' SASD G' SASD G' SASD G' SASD G' SASD G' SASD G' SASD G' SASD G' SASD G' SASD G' SASD G' SASD G' SASD G' SASD G' SASD G' SASD G' SASD G' SASD G' SASD G' SASD G' SASD G' SASD G' 9 715 51.9 36'' 765 52.9 813 53.8 903 55.2 1123 57.9 1394 60.3 948 71.9 1021 73.7 1090 75.2 1218 77.7 1522 82.5 1873* 87.1 1171 110.2 1266 113.8 1355 117.1 1519 122.4 1902 133.0 2328* 143.6 1297 148.7 1405 154.8 1506 160.1 1692 169.1 2120 187.5 2585 206.5 7 499 48.5 554 50.2 607 51.5 706 53.5 941 57.0 1211 60.0 668 66.1 749 68.8 825 71.1 964 74.6 1288 80.9 1630 86.4 831 98.7 935 104.0 1033 108.5 1211 115.8 1616 129.5 2027 142.1 923 130.5 1042 138.9 1153 146.1 1355 158.0 1806 181.3 2251 203.7 5'-0" 9 7 612 431 56.4 52.0 666 1-1/2'' 489 58.1 54.5 719 545 59.5 56.5 817 649 61.7 59.6 1060 902 65.8 64.8 1362 1193 69.4 69.0 815 581 75.9 68.9 894 665 78.7 72.9 970 745 81.0 76.1 1110 894 84.8 81.2 1447 1241 91.9 90.2 1838* 1611 98.5 97.8 1010 724 111.6 98.8 1112 833 116.9 106.0 1210 937 121.5 112.1 1390 1127 129.0 121.8 1814 1562 143.7 139.9 2289* 2006 157.9 156.3 1120 807 146.3 127.0 1237 931 154.5 137.7 1348 1049 161.6 147.0 1552 1265 173.6 162.2 2027 1750 197.8 191.5 2544 2230 222.3 219.5 Span (ft- in.) 6'-0" 7'-0" 8'-0" Fasteners per sheet to support 36/9 9 7 9 7 9 7 529 378 467 341 421 313 6'' mm 59.2 54.1 60.9 55.4 62.0152 56.0 36'' 596 444 534 408 488 380 61.6 57.5 64.1 59.6 65.8 61.1 651 501 601 469 555 445 63.6 60.2 66.7 63.0 69.0 65.1 755 610 708 580 672 558 66.7 64.3 70.7 68.1 73.8 71.1 1014 874 980 853 952 837 36/11 72.3 71.2 77.7 76.5 82.4 81.1 1338 1180 1321 1170 1188 1163 6'' 77.1 76.7 83.8 83.3 89.5 89.1 36'' 715 517 635 468 575 432 77.9 70.1 78.7 70.4 78.8 70.3 804 607 734 564 673 530 81.7 75.3 83.5 76.7 84.5 77.5 883 690 819 649 769 618 84.9 79.5 87.5 81.8 89.3 83.5 1032 844 973 808 927 779 90.0 86.1 93.9 89.7 96.8 92.6 1392 1208 1350 1183 1317 1164 99.4 97.5 105.4 103.4 110.4 108.4 1812* 1597 1793* 1587 1547 1547 107.8 107.1 115.7 114.9 122.4 121.6 895 651 800 593 726 548 111.0 97.5 109.4 95.7 107.4 93.8 1003 763 921 712 855 672 117.8 106.4 117.5 106.0 116.7 105.3 1106 870 1028 821 968 784 123.6 113.8 124.5 114.7 124.7 115.0 1296 1068 1226 1024 1171 991 133.2 125.8 135.9 128.4 137.7 130.3 1750 1524 1702 1496 1664 1474 151.6 147.7 157.6 153.8 162.3 158.6 2260* 1991 2239 1980 2219 1971 169.1 167.5 178.1 176.5 185.5 183.9 995 726 897 667 816 617 142.3 122.9 137.9 118.9 133.7 115.3 1117 855 1028 798 960 755 152.3 135.6 149.6 133.2 146.7 130.8 1234 977 1150 923 1084 882 161.1 146.5 159.7 145.5 158.0 144.2 1451 1201 1374 1153 1315 1117 175.7 164.3 176.6 165.5 176.8 166.1 1959 1709 1908 1679 1867 1656 205.0 198.7 210.1 204.1 214.0 208.2 2515 2215 2493 2203 2476 2195 234.2 231.5 243.4 240.8 250.7 248.2 9'-0" 914/11 9 7 388 292 62.5 56.4 1-1/2'' mm 455 714 360 67.0 62.1 522 426 70.7 66.8 643 540 76.4 73.6 931 824 86.3 85.1 938 938 94.6 94.1 1-1/2'' 528 403 78.5 69.9 627 502 85.1 78.0 725 594 90.5 84.7 891 757 99.1 94.9 1222 1149 114.6 112.6 1222 1222 128.1 127.3 669 513 105.2 92.0 798 641 115.6 104.4 920 754 124.5 115.0 1128 964 138.9 131.7 1633 1456 166.2 162.5 1753 1753 191.6 190.1 753 579 129.7 112.0 901 721 143.9 128.7 1032 850 156.2 143.0 1268 1088 176.7 166.4 1835 1638 217.0 211.4 2191 2188 256.7 254.3 10'-0" 9 363 62.7 430 67.9 497 72.1 620 78.6 760 89.8 760 99.1 495 77.9 593 85.3 692 91.4 861 100.9 990 118.1 990 133.1 623 103.1 752 114.4 881 124.1 1092 139.7 1420 169.3 1420 196.8 703 126.0 851 141.2 989 154.5 1229 176.3 1775 219.4 1775 261.7 7 277 56.5 344 38 mm 62.9 410 68.1 526 75.7 760 88.5 760 98.6 383 69.3 481 78.2 574 85.5 739 96.7 990 116.1 990 132.3 485 90.2 614 103.6 730 114.8 942 132.7 1420 165.7 1420 195.4 548 109.1 694 126.7 824 141.8 1065 166.5 1623 214.1 1775 259.4 1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses 3/16" ≤ tf ≤ 3/8". For attachment to base steel with range 1/8" ≤ tf < 3/16", diaphragm shear values should be calculated in accordance with Section 1.1.8. 2 Tabulated LRFD diaphragm shear loads are calculated with a phi factor (Φ) of 0.70 for wind loads. 3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60. *For noted diaphragm shear values, please see footnote 2 of Table 10 (page 19). 26 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 6'' 36'' 1-1/2'' 6'' 152 mm 36'' 1-1/2'' 914 mm 38 mm Steel Deck Fastening Systems X-HSN 24 for Fastening Deck to Bar Joist 1.2 36/4 36/5 6'' 36'' 1-1/2'' 6'' 152 mm 36'' 914/5 1-1/2'' 914 mm 38 mm Allowable Stress Design (ASD) - Allowable diaphragm shears, SASD, (plf) and stiffness factors, G', (kips/in.) for standard 1-1/2" deep flutes, 6" center-to-center steel deck (Fy ≥ 33 ksi; Fu ≥ 45 ksi) installed with Hilti X-HSN 24 fasteners with 36/5 or 36/4 end and interior support fastener patterns1,2,3,4,5 Gauge Sidelap spacing Hilti SLC6,7,8 36" O.C. 24" O.C. 18" O.C. 22 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 20 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 18 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 16 12" O.C. 6" O.C. 3" O.C. 1 2 3 Factor 36/7 4'-0" 5 SASD 448 6'' G' 13.2 36'' SASD 495 G' 13.4 SASD 537 G' 13.5 SASD 612 G' 13.7 SASD 766 36/9 G' 13.9 SASD 766 6'' G' 14.1 36'' SASD 600 G' 20.4 SASD 666 G' 20.7 SASD 727 G' 20.9 SASD 830 36/11 G' 21.3 SASD 1032 6'' G' 21.8 36'' SASD 1032 G' 22.2 SASD 745 G' 36.7 SASD 830 G' 37.6 SASD 907 G' 38.3 SASD 1037 G' 39.4 SASD 1285 G' 41.0 SASD 1285 G' 42.3 SASD 827 G' 57.6 SASD 924 G' 59.6 SASD 1011 G' 61.2 SASD 1156 G' 63.6 SASD 1428 G' 67.5 SASD 1428 G' 70.6 4 365 9.7 407 9.8 445 9.8 508 9.9 623 10.1 623 10.2 490 15.0 550 15.2 603 15.4 688 15.6 834 16.0 834 16.2 609 27.6 687 28.3 753 28.8 859 29.5 1034 30.6 1034 31.3 678 44.2 765 45.7 840 46.9 957 48.6 1146 51.2 1146 53.1 5'-0" 5 4 393 325 15.8 11.6 1-1/2'' 444 372 16.1 11.8 491 414 16.3 12.0 573 484 16.6 12.1 744 611 17.0 12.4 744 611 17.3 12.6 1-1/2'' 530 439 23.9 17.8 602 506 24.4 18.2 668 564 24.9 18.5 783 659 25.5 18.9 1008 822 26.4 19.5 1-1/2'' 1008 822 27.1 19.9 660 549 41.7 31.9 753 634 43.3 33.1 838 708 44.5 33.9 982 826 46.2 35.1 1258 1021 48.8 36.8 1258 1021 50.8 38.0 735 612 63.4 49.6 841 708 66.6 52.2 936 791 69.2 54.0 1098 922 72.9 56.7 1400 1133 78.9 60.8 1400 1133 83.6 63.8 Span (ft- in.) 6'-0" 7'-0" 8'-0" Fasteners per sheet to support 36/5 5 4 5 4 5 4 354 296 325 275 299 257 6'' 152 mm 18.1 13.4 20.1 15.1 21.9 16.6 36'' 408 346 380 327 359 312 18.5 13.7 20.7 15.5 22.7 17.2 457 391 432 374 412 360 18.8 14.0 21.2 15.8 23.4 17.6 545 466 524 453 507 442 19.3 14.2 21.8 16.2 24.2 18.1 729 603 717 597 707 592 36/7 19.9 14.6 22.7 16.8 25.3 18.8 729 603 717 597 707 592 6'' 152 mm 20.3 14.9 23.3 17.1 26.1 19.3 36'' 479 403 442 376 413 355 26.9 20.3 29.4 22.5 31.6 24.5 556 474 522 450 495 431 27.8 21.0 30.7 23.4 33.3 25.7 626 536 595 515 570 499 28.4 21.4 31.6 24.1 34.5 26.5 748 638 722 622 702 610 36/9 29.3 22.0 32.9 24.9 36.1 27.6 990 813 977 806 967 801 6'' 152 mm 30.7 22.8 34.7 26.0 38.5 29.1 36'' 990 813 977 806 967 801 31.6 23.4 36.0 26.8 40.1 30.0 599 505 554 473 519 447 45.7 35.5 48.7 38.4 51.1 40.9 698 596 657 567 624 545 47.9 37.2 51.8 40.8 55.0 43.9 788 675 750 650 721 631 36/11 49.7 38.5 54.1 42.5 57.9 46.0 942 802 912 783 888 769 6'' 52.1 40.2 57.4 44.8 62.0 48.9 36'' 1238 1011 1223 1004 1211 998 55.9 42.6 62.4 48.0 68.3 53.1 1238 1011 1223 1004 1211 998 58.7 44.3 66.0 50.3 72.8 55.9 669 565 619 529 581 502 67.5 53.8 70.3 56.9 72.3 59.4 781 667 736 636 701 612 72.0 57.3 76.1 61.6 79.3 65.1 882 756 842 729 810 708 75.5 60.0 80.6 65.1 84.8 69.4 1055 897 1022 877 997 862 80.7 63.8 87.2 70.0 92.8 75.4 1380 1123 1364 1116 1352 1110 89.0 69.5 97.8 77.3 105.7 84.5 1380 1123 1364 1116 1352 1110 95.3 73.5 105.9 82.6 115.5 91.0 9'-0" 10'-0" 914/7 5 4 5 280 242 265 23.5 18.0 24.9 1-1/2'' 914 mm 343 300 329 24.6 18.8 26.3 397 350 384 25.4 19.3 27.2 494 434 483 26.4 20.0 28.5 700 588 694 914/9 27.8 20.8 30.3 700 588 694 28.8 21.4 31.4 1-1/2'' 914 mm 387 338 368 33.5 26.2 35.1 474 416 456 35.6 27.7 37.6 551 485 535 37.1 28.8 39.5 686 600 673 914/11 39.1 30.2 41.9 958 797 951 42.1 32.0 45.4 714 mm1-1/2'' 958 797 951 44.0 33.2 47.8 492 427 467 53.0 42.9 54.5 599 527 578 57.7 46.6 60.0 698 615 678 61.2 49.2 64.1 869 757 853 66.2 52.8 69.9 1-1/2'' 1202 994 1194 73.7 57.8 78.7 1202 994 1194 79.1 61.2 85.0 551 480 527 73.6 61.3 74.6 673 593 650 81.8 68.0 83.8 785 691 764 88.2 73.1 91.1 977 850 960 97.6 80.3 101.8 1342 1106 1334 112.7 91.1 119.0 1342 1106 1334 124.3 98.8 132.3 4 232 19.2 38 mm 290 20.2 341 20.9 427 21.7 585 22.8 585 23.4 38 mm 324 27.8 404 29.6 475 30.9 592 32.6 794 34.8 38 mm 794 36.2 411 44.7 512 49.0 602 52.1 748 56.3 990 62.3 990 66.3 462 62.8 577 70.5 678 76.3 840 84.6 1102 97.1 1102 106.1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses 3/16" ≤ tf ≤ 3/8". For attachment to base steel with range 1/8" ≤ tf < 3/16", diaphragm shear values should be calculated in accordance with Section 1.1.8. Tabulated LRFD diaphragm shear loads are calculated with a phi factor (Φ) of 0.70 for wind loads.. Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 27 6'' 36'' 1-1/2'' 6'' 36'' 152 mm 1-1/2'' 914 mm 38 mm Steel Deck Fastening Systems 1.2 X-HSN 24 for Fastening Deck to Bar Joist 36/7 36/9 6'' 36'' 1-1/2'' 6'' 36'' 914/9 152 mm 1-1/2'' 914 mm 38 mm Load Resistance Factor Design (LRFD) - Factored resistance diaphragm shears, SLRFD, (plf) and stiffness factors, G', (kips/in.) for standard 1-1/2" deep flutes, 6" center-to-center steel deck (Fy ≥ 33 ksi; Fu ≥ 45 ksi) installed with Hilti X-HSN 24 fasteners with 36/9 or 36/7 end and interior support fastener patterns1,2,3,4,5 Gauge Sidelap spacing Hilti SLC6,7,8 36" O.C. 24" O.C. 18" O.C. 22 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 20 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 18 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 16 12" O.C. 6" O.C. 3" O.C. Factor 36/11 4'-0" 9 SLRFD 1174 6'' G' 51.9 36'' SLRFD 1257 G' 52.9 SLRFD 1336 G' 53.8 SLRFD 1484 G' 55.2 SLRFD 1846 G' 57.9 SLRFD 2291 G' 60.3 SLRFD 1558 G' 71.9 SLRFD 1678 G' 73.7 SLRFD 1791 G' 75.2 SLRFD 2001 G' 77.7 SLRFD 2501 G' 82.5 SLRFD 3078* G' 87.1 SLRFD 1925 G' 110.2 SLRFD 2080 G' 113.8 SLRFD 2227 G' 117.1 SLRFD 2496 G' 122.4 SLRFD 3125 G' 133.0 SLRFD 3825* G' 143.6 SLRFD 2131 G' 148.7 SLRFD 2308 G' 154.8 SLRFD 2475 G' 160.1 SLRFD 2780 G' 169.1 SLRFD 3484 G' 187.5 SLRFD 4247 G' 206.5 7 820 48.5 911 50.2 998 51.5 1159 53.5 1547 57.0 1990 60.0 1098 66.1 1230 68.8 1355 71.1 1585 74.6 2116 80.9 2679 86.4 1365 98.7 1536 104.0 1697 108.5 1990 115.8 2655 129.5 3331 142.1 1517 130.5 1712 138.9 1895 146.1 2227 158.0 2968 181.3 3699 203.7 5'-0" 9 7 1005 708 56.4 52.0 1-1/2'' 1095 803 58.1 54.5 1181 895 59.5 56.5 1342 1067 61.7 59.6 1742 1482 65.8 64.8 2238 1960 69.4 69.0 1339 954 75.9 68.9 1469 1093 78.7 72.9 1593 1225 81.0 76.1 1823 1469 84.8 81.2 2377 2039 91.9 90.2 3020* 2647 98.5 97.8 1660 1190 111.6 98.8 1828 1370 116.9 106.0 1988 1540 121.5 112.1 2283 1852 129.0 121.8 2981 2567 143.7 139.9 3761* 3296 157.9 156.3 1841 1326 146.3 127.0 2033 1531 154.5 137.7 2215 1724 161.6 147.0 2550 2078 173.6 162.2 3331 2875 197.8 191.5 4181 3664 222.3 219.5 Span (ft- in.) 6'-0" 7'-0" 8'-0" Fasteners per sheet to support 36/9 9 7 9 7 9 7 869 622 768 560 692 514 6'' mm 59.2 54.1 60.9 55.4 62.0152 56.0 36'' 979 729 878 671 802 624 61.6 57.5 64.1 59.6 65.8 61.1 1070 824 987 771 912 731 63.6 60.2 66.7 63.0 69.0 65.1 1240 1002 1164 954 1104 917 66.7 64.3 70.7 68.1 73.8 71.1 1667 1436 1610 1402 1565 1375 36/11 72.3 71.2 77.7 76.5 82.4 81.1 2199 1939 2170 1923 1900 1900 6'' 77.1 76.7 83.8 83.3 89.5 89.1 36'' 1175 850 1044 770 945 710 77.9 70.1 78.7 70.4 78.8 70.3 1321 997 1206 927 1107 872 81.7 75.3 83.5 76.7 84.5 77.5 1451 1134 1346 1067 1264 1016 84.9 79.5 87.5 81.8 89.3 83.5 1695 1387 1599 1327 1524 1281 90.0 86.1 93.9 89.7 96.8 92.6 2287 1985 2218 1944 2165 1913 99.4 97.5 105.4 103.4 110.4 108.4 2978* 2625 2946* 2608 2475 2475 107.8 107.1 115.7 114.9 122.4 121.6 1471 1069 1314 974 1193 900 111.0 97.5 109.4 95.7 107.4 93.8 1648 1254 1514 1169 1405 1105 117.8 106.4 117.5 106.0 116.7 105.3 1817 1430 1689 1350 1590 1288 123.6 113.8 124.5 114.7 124.7 115.0 2130 1755 2014 1683 1925 1628 133.2 125.8 135.9 128.4 137.7 130.3 2876 2504 2796 2458 2734 2421 151.6 147.7 157.6 153.8 162.3 158.6 3714* 3272 3679 3254 3550 3240 169.1 167.5 178.1 176.5 185.5 183.9 1635 1193 1474 1095 1341 1014 142.3 122.9 137.9 118.9 133.7 115.3 1836 1404 1690 1312 1577 1241 152.3 135.6 149.6 133.2 146.7 130.8 2028 1605 1889 1517 1781 1450 161.1 146.5 159.7 145.5 158.0 144.2 2384 1973 2259 1895 2161 1835 175.7 164.3 176.6 165.5 176.8 166.1 3219 2809 3135 2760 3068 2721 205.0 198.7 210.1 204.1 214.0 208.2 4133 3639 4097 3621 4068 3606 234.2 231.5 243.4 240.8 250.7 248.2 9'-0" 914/11 9 7 638 481 62.5 56.4 1-1/2'' 714 mm 748 591 67.0 62.1 858 700 70.7 66.8 1057 888 76.4 73.6 1501 1354 86.3 85.1 1501 1501 94.6 94.1 1-1/2'' 868 663 78.5 69.9 1030 825 85.1 78.0 1192 975 90.5 84.7 1464 1244 99.1 94.9 1956 1888 114.6 112.6 1956 1956 128.1 127.3 1099 843 105.2 92.0 1311 1053 115.6 104.4 1511 1239 124.5 115.0 1853 1584 138.9 131.7 2684 2393 166.2 162.5 2805 2805 191.6 190.1 1238 952 129.7 112.0 1481 1185 143.9 128.7 1695 1397 156.2 143.0 2084 1788 176.7 166.4 3015 2691 217.0 211.4 3506 3506 256.7 254.3 10'-0" 9 596 62.7 706 67.9 817 72.1 1019 78.6 1216 89.8 1216 99.1 813 77.9 975 85.3 1137 91.4 1415 100.9 1584 118.1 1584 133.1 1024 103.1 1236 114.4 1447 124.1 1795 139.7 2272 169.3 2272 196.8 1155 126.0 1398 141.2 1626 154.5 2020 176.3 2840 219.4 2840 261.7 7 455 56.5 38 mm 565 62.9 674 68.1 864 75.7 1216 88.5 1216 98.6 629 69.3 791 78.2 943 85.5 1214 96.7 1584 116.1 1584 132.3 797 90.2 1009 103.6 1200 114.8 1549 132.7 2272 165.7 2272 195.4 901 109.1 1140 126.7 1354 141.8 1750 166.5 2666 214.1 2840 259.4 1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses 3/16" ≤ tf ≤ 3/8". For attachment to base steel with range 1/8" ≤ tf < 3/16", diaphragm shear values should be calculated in accordance with Section 1.1.8. 2 Tabulated LRFD diaphragm shear loads are calculated with a phi factor (Φ) of 0.70 for wind loads. To calculate LRFD values for load combinations involving earthquake, divide values in table by 0.70 and multiply by a phi factor (Φ) of 0.65. Panel buckling has been checked. 3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60. *For noted diaphragm shear values, please see footnote 2 of Table 10 (page 19) of this document 28 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 6'' 36'' 1-1/2'' 6'' 152 mm 36'' 1-1/2'' 914 mm 38 mm Steel Deck Fastening Systems X-HSN 24 for Fastening Deck to Bar Joist 1.2 36/4 36/5 6'' 36'' 1-1/2'' 6'' 152 mm 36'' 914/5 1-1/2'' 914 mm 38 mm Load Resistance Factor Design (LRFD) - Factored resistance diaphragm shears, SLRFD, (plf) and stiffness factors, G', (kips/in.) for standard 1-1/2" deep flutes, 6" center-to-center steel deck (Fy ≥ 33 ksi; Fu ≥ 45 ksi) installed with Hilti X-HSN 24 fasteners with 36/5 or 36/4 end and interior support fastener patterns1,2,3,4,5 Gauge Sidelap spacing Hilti SLC6,7,8 36" O.C. 24" O.C. 18" O.C. 22 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 20 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 18 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 16 12" O.C. 6" O.C. 3" O.C. Factor 36/7 4'-0" 5 SLRFD 737 6'' G' 13.2 36'' SLRFD 813 G' 13.4 SLRFD 883 G' 13.5 SLRFD 1006 G' 13.7 SLRFD 1259 36/9 G' 13.9 SLRFD 1259 6'' G' 14.1 36'' SLRFD 985 G' 20.4 SLRFD 1095 G' 20.7 SLRFD 1194 G' 20.9 SLRFD 1364 36/11 G' 21.3 SLRFD 1696 6'' G' 21.8 36'' SLRFD 1696 G' 22.2 SLRFD 1224 G' 36.7 SLRFD 1364 G' 37.6 SLRFD 1490 G' 38.3 SLRFD 1704 G' 39.4 SLRFD 2111 G' 41.0 SLRFD 2111 G' 42.3 SLRFD 1359 G' 57.6 SLRFD 1518 G' 59.6 SLRFD 1661 G' 61.2 SLRFD 1900 G' 63.6 SLRFD 2347 G' 67.5 SLRFD 2347 G' 70.6 4 599 9.7 669 9.8 732 9.8 835 9.9 1023 10.1 1023 10.2 805 15.0 904 15.2 991 15.4 1131 15.6 1370 16.0 1370 16.2 1001 27.6 1128 28.3 1238 28.8 1411 29.5 1699 30.6 1699 31.3 1114 44.2 1257 45.7 1380 46.9 1572 48.6 1884 51.2 1884 53.1 5'-0" 5 4 646 534 15.8 11.6 1-1/2'' 729 611 16.1 11.8 806 680 16.3 12.0 942 795 16.6 12.1 1223 1005 17.0 12.4 1223 1005 17.3 12.6 1-1/2'' 870 722 23.9 17.8 989 831 24.4 18.2 1098 928 24.9 18.5 1286 1083 25.5 18.9 1656 1350 26.4 19.5 1-1/2'' 1656 1350 27.1 19.9 1084 902 41.7 31.9 1238 1042 43.3 33.1 1377 1163 44.5 33.9 1614 1357 46.2 35.1 2067 1677 48.8 36.8 2067 1677 50.8 38.0 1207 1005 63.4 49.6 1382 1164 66.6 52.2 1538 1300 69.2 54.0 1804 1515 72.9 56.7 2301 1862 78.9 60.8 2301 1862 83.6 63.8 Span (ft- in.) 6'-0" 7'-0" 8'-0" Fasteners per sheet to support 36/5 5 4 5 4 5 4 582 487 534 452 491 422 6'' 152 mm 18.1 13.4 20.1 15.1 21.9 16.6 36'' 670 569 625 537 590 513 18.5 13.7 20.7 15.5 22.7 17.2 751 643 710 614 678 592 18.8 14.0 21.2 15.8 23.4 17.6 896 766 861 744 833 726 19.3 14.2 21.8 16.2 24.2 18.1 1197 991 1178 981 1162 973 36/7 19.9 14.6 22.7 16.8 25.3 18.8 1197 991 1178 981 1162 973 6'' 152 mm 20.3 14.9 23.3 17.1 26.1 19.3 36'' 788 662 727 618 679 583 26.9 20.3 29.4 22.5 31.6 24.5 914 779 857 739 813 708 27.8 21.0 30.7 23.4 33.3 25.7 1029 882 977 847 937 820 28.4 21.4 31.6 24.1 34.5 26.5 1230 1049 1187 1023 1154 1002 36/9 29.3 22.0 32.9 24.9 36.1 27.6 1628 1336 1606 1325 1588 1317 6'' 152 mm 30.7 22.8 34.7 26.0 38.5 29.1 36'' 1628 1336 1606 1325 1588 1317 31.6 23.4 36.0 26.8 40.1 30.0 985 830 911 777 853 735 45.7 35.5 48.7 38.4 51.1 40.9 1147 979 1079 932 1026 895 47.9 37.2 51.8 40.8 55.0 43.9 1295 1109 1233 1068 1185 1036 36/11 49.7 38.5 54.1 42.5 57.9 46.0 1548 1317 1498 1287 1459 1264 6'' 52.1 40.2 57.4 44.8 62.0 48.9 36'' 2034 1662 2010 1650 1991 1640 55.9 42.6 62.4 48.0 68.3 53.1 2034 1662 2010 1650 1991 1640 58.7 44.3 66.0 50.3 72.8 55.9 1099 928 1018 869 955 824 67.5 53.8 70.3 56.9 72.3 59.4 1283 1096 1209 1045 1152 1005 72.0 57.3 76.1 61.6 79.3 65.1 1450 1242 1383 1198 1331 1164 75.5 60.0 80.6 65.1 84.8 69.4 1733 1473 1680 1441 1638 1416 80.7 63.8 87.2 70.0 92.8 75.4 2267 1846 2242 1834 2222 1824 89.0 69.5 97.8 77.3 105.7 84.5 2267 1846 2242 1834 2222 1824 95.3 73.5 105.9 82.6 115.5 91.0 9'-0" 914/7 10'-0" 5 4 5 460 398 436 23.5 18.0 24.9 1-1/2'' 914 mm 563 493 540 24.6 18.8 26.3 652 574 631 25.4 19.3 27.2 811 712 793 26.4 20.0 28.5 1150 967 1140 914/9 27.8 20.8 30.3 1150 967 1140 28.8 21.4 31.4 1-1/2'' 914 mm 636 556 605 33.5 26.2 35.1 778 684 750 35.6 27.7 37.6 905 798 878 37.1 28.8 39.5 1127 986 1105 914/11 39.1 30.2 41.9 1574 1310 1563 42.1 32.0 45.4 714 mm1-1/2'' 1574 1310 1563 44.0 33.2 47.8 808 702 768 53.0 42.9 54.5 984 866 950 57.7 46.6 60.0 1146 1010 1115 61.2 49.2 64.1 1427 1245 1402 66.2 52.8 69.9 1-1/2'' 1975 1633 1962 73.7 57.8 78.7 1975 1633 1962 79.1 61.2 85.0 906 788 865 73.6 61.3 74.6 1106 974 1069 81.8 68.0 83.8 1290 1136 1256 88.2 73.1 91.1 1605 1396 1578 97.6 80.3 101.8 2206 1817 2193 112.7 91.1 119.0 2206 1817 2193 124.3 98.8 132.3 4 381 19.2 38 mm 477 20.2 560 20.9 701 21.7 962 22.8 962 23.4 38 mm 532 27.8 663 29.6 780 30.9 972 32.6 1304 34.8 38 mm 1304 36.2 675 44.7 842 49.0 989 52.1 1229 56.3 1627 62.3 1627 66.3 759 62.8 948 70.5 1114 76.3 1380 84.6 1810 97.1 1810 106.1 1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses 3/16" ≤ tf ≤ 3/8". For attachment to base steel with range 1/8" ≤ tf < 3/16", diaphragm shear values should be calculated in accordance with Section 1.1.8. 2 Tabulated LRFD diaphragm shear loads are calculated with a phi factor (Φ) of 0.70 for wind loads. To calculate LRFD values for load combinations involving earthquake, divide values in table by 0.70 and multiply by a phi factor (Φ) of 0.65. Panel buckling has been checked. 3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 29 6'' 914 mm 1-1/2'' 36'' 38 mm 152 mm 914 mm 38 mm Steel Deck Fastening Systems 1.2 X-HSN 24 for Fastening Deck to Bar Joist 36/7 914/9 (36/9) 914/9 6'' 152 mm 36'' c 914/7 (36/7) 914/7 914 mm 1-1/2'' 38 mm 152 mm 914 mm 38 mm Limit States Design (LSD) - Factored resistance diaphragm shears, SLSD, (N/mm) and stiffness factors, G', (103 N/mm) for standard 38 mm deep flutes, 152 mm center-to-center steel deck (Fy ≥ 230 MPa; Fu ≥ 310 MPa) installed with Hilti X-HSN 24 fasteners with 914/9 (36/9) or 914/7 (36/7) end and interior support fastener patterns1,2,3,4,5 Gauge Sidelap spacing Hilti36/9 SLC6,7,8 900 152O.C. mm 6''mm 36'' 600 mm O.C.. 450 mm O.C. 22 300 mm O.C. 150 36/11 mm O.C. 75 6''mm O.C. 36'' 900 mm O.C. 600 mm O.C. 450 mm O.C. 20 300 mm O.C. 150 mm O.C. 75 mm O.C. 900 mm O.C. 600 mm O.C. 450 mm O.C. 18 300 mm O.C. 150 mm O.C. 75 mm O.C. 900 mm O.C. 600 mm O.C. 450 mm O.C. 16 300 mm O.C. 150 mm O.C. 75 mm O.C. Factor 914/11 4'-0" 9 7 SLSD 16.1 11.3 G' 9.0 8.5 714 mm 1-1/2'' SLSD 17.3 12.5 G' 9.2 8.7 SLSD 18.3 13.7 G' 9.4 9.0 SLSD 20.3 15.9 G' 9.6 9.3 SLSD 25.3 21.2 G' 10.0 9.9 SLSD 31.2* 27.1 G' 10.5 10.4 1-1/2'' SLSD 21.4 15.1 G' 12.5 11.5 SLSD 23.0 16.9 G' 12.8 12.0 SLSD 24.6 18.6 G' 13.1 12.4 SLSD 27.4 21.7 G' 13.5 13.0 SLSD 34.2 28.9 G' 14.4 14.1 SLSD 41.9* 36.5 G' 15.1 15.0 SLSD 26.4 18.8 G' 19.3 17.3 SLSD 28.5 21.1 G' 19.9 18.2 SLSD 30.5 23.3 G' 20.5 19.0 SLSD 34.2 27.3 G' 21.4 20.3 SLSD 42.7 36.3 G' 23.2 22.6 SLSD 52.1* 45.4 G' 25.0 24.7 SLSD 29.3 20.8 G' 26.1 22.9 SLSD 31.7 23.5 G' 27.1 24.4 SLSD 33.9 26.0 G' 28.1 25.6 SLSD 38.1 30.5 G' 29.6 27.7 SLSD 47.6 40.6 G' 32.8 31.7 SLSD 57.8 50.4 G' 36.0 35.6 5'-0" 9 13.8 9.8 38 15.0 10.1 16.2 10.4 18.4 10.7 23.9 11.4 30.5 12.0 18.4 13.3 20.2 13.7 21.9 14.2 25.0 14.8 32.5 16.0 41.2* 17.1 22.8 19.6 25.1 20.5 27.3 21.3 31.3 22.6 40.8 25.1 51.2* 27.5 25.3 25.7 27.9 27.1 30.4 28.4 35.0 30.4 45.5 34.6 56.9 38.8 7 9.7 9.1 mm 11.0 9.5 12.3 9.9 14.6 10.4 20.3 11.3 26.7 12.0 13.1 12.1 15.0 12.7 16.8 13.3 20.2 14.2 27.9 15.7 36.1 17.0 16.4 17.3 18.8 18.6 21.2 19.7 25.4 21.3 35.1 24.5 44.9 27.3 18.2 22.4 21.0 24.2 23.7 25.8 28.5 28.5 39.3 33.5 49.9 38.4 Span (ft- in.) 6'-0" 7'-0" 8'-0" Fasteners per sheet to support 914/9 9 7 9 7 9 7 12.0 8.6 10.6 7.7 9.5 7.1 152 mm 10.3 9.5 10.7 9.7 10.9 9.8 914 mm 13.5 10.0 12.1 9.2 11.1 8.6 10.8 10.1 11.2 10.4 11.5 10.7 14.7 11.3 13.6 10.6 12.6 10.1 11.1 10.5 11.6 11.0 12.1 11.4 17.0 13.8 16.0 13.1 15.2 12.6 11.6 11.2 12.3 11.9 12.9 12.4 22.8 19.7 22.1 19.2 21.4 18.8 914/11 12.6 12.4 13.5 13.3 14.4 14.1 30.0 26.4 29.6 26.2 26.8 26.1 152 mm 13.4 13.3 14.6 14.5 15.6 15.5 714 mm 16.2 11.7 14.4 10.6 13.0 9.8 13.6 12.3 13.8 12.4 13.8 12.4 18.1 13.7 16.6 12.8 15.3 12.0 14.3 13.2 14.6 13.5 14.8 13.6 19.9 15.6 18.5 14.7 17.4 14.0 14.9 13.9 15.3 14.3 15.7 14.6 23.3 19.0 21.9 18.2 20.9 17.6 15.7 15.0 16.4 15.7 17.0 16.2 31.3 27.2 30.4 26.6 29.6 26.2 17.3 17.0 18.4 18.1 19.3 18.9 40.6* 35.8 40.2* 35.5 35.0 35.0 18.8 18.6 20.2 20.0 21.3 21.2 20.2 14.7 18.1 13.4 16.4 12.4 19.5 17.2 19.2 16.9 18.9 16.5 22.6 17.2 20.8 16.1 19.4 15.2 20.7 18.7 20.7 18.7 20.5 18.5 25.0 19.7 23.2 18.5 21.8 17.7 21.7 20.0 21.9 20.2 21.9 20.2 29.2 24.1 27.7 23.1 26.4 22.4 23.3 22.1 23.8 22.5 24.2 22.9 39.4 34.3 38.3 33.6 37.4 33.1 26.5 25.8 27.6 26.9 28.4 27.8 50.6* 44.6 50.1* 44.3 49.8 44.1 29.5 29.2 31.1 30.8 32.4 32.1 22.5 16.4 20.3 15.1 18.5 14.0 25.1 21.7 24.3 21.0 23.6 20.4 25.2 19.3 23.2 18.0 21.7 17.1 26.8 23.9 26.3 23.5 25.9 23.1 27.9 22.1 26.0 20.9 24.5 19.9 28.3 25.8 28.1 25.6 27.8 25.4 32.7 27.1 31.0 26.0 29.7 25.2 30.9 28.9 31.0 29.1 31.1 29.2 44.0 38.4 42.9 37.8 42.0 37.2 35.9 34.8 36.9 35.8 37.6 36.5 56.3 49.6 55.8 49.3 55.4 49.1 40.9 40.5 42.6 42.1 43.9 43.5 9'-0" 9 8.8 11.0 10.3 11.7 11.8 12.4 14.5 13.4 21.0 15.1 21.2 16.5 12.0 13.8 14.2 14.9 16.4 15.9 20.1 17.4 27.6 20.0 27.6 22.3 15.2 18.5 18.1 20.4 20.8 21.9 25.4 24.4 36.7 29.1 39.6 33.5 17.1 22.9 20.4 25.4 23.3 27.5 28.6 31.1 41.3 38.1 49.5 45.0 10'-0" 7 9 6.6 8.2 9.9 11.0 38 mm 8.1 9.7 10.9 11.9 9.6 11.2 11.7 12.6 12.2 14.0 12.9 13.8 18.6 17.2 14.8 15.7 21.2 17.2 16.4 17.3 38 mm 9.1 11.2 12.3 13.7 11.4 13.4 13.7 15.0 13.4 15.7 14.9 16.0 17.1 19.4 16.6 17.7 25.8 22.4 19.7 20.7 27.6 22.4 22.2 23.2 11.6 14.1 16.2 18.2 14.5 17.0 18.4 20.2 17.0 19.9 20.2 21.8 21.8 24.6 23.2 24.6 32.8 32.1 28.5 29.7 39.6 32.1 33.2 34.4 13.1 15.9 19.8 22.3 16.3 19.3 22.7 24.9 19.2 22.3 25.2 27.2 24.6 27.7 29.3 31.1 36.8 40.1 37.1 38.5 49.0 40.1 44.6 45.9 7 6.3 9.9 7.8 11.0 9.3 11.9 11.9 13.3 17.2 15.5 17.2 17.2 8.7 12.2 10.9 13.8 13.0 15.0 16.7 17.0 22.4 20.3 22.4 23.1 11.0 15.9 13.9 18.3 16.5 20.2 21.3 23.3 32.1 29.1 32.1 34.2 12.4 19.3 15.7 22.4 18.6 25.0 24.0 29.3 36.5 37.6 40.1 45.5 1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses 5 mm ≤ tf ≤ 10 mm. For attachment to base steel thickness with range 3 mm ≤ tf < 5 mm, diaphragm shear values should be calculated in accordance with Section 1.1.8. 2 Tabulated LRFD diaphragm shear loads are calculated with a phi factor (Φ) of 0.65 for wind loads. To calculate LRFD values for load combinations involving earthquake, divide values in table by 0.65 and multiply by a phi factor (Φ) of 0.60. Panel buckling has been checked. 3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60. *For noted diaphragm shear values, please see footnote 2 of Table 10 (page 19) of this document 30 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 6'' 914 mm 1-1/2'' 36'' 38 mm 152 mm 914 mm 38 mm Steel Deck Fastening Systems X-HSN 24 for Fastening Deck to Bar Joist 1.2 c 36/4 914/5 (36/5) 914/5 6'' 152 mm 36'' 914/4 (36/4) 914/4 914 mm 1-1/2'' 38 mm 152 mm 914 mm 38 mm Limit States Design (LSD) - Factored resistance diaphragm shears, SLSD, (N/mm) and stiffness factors, G', (103 N/mm) for standard 38 mm deep flutes, 152 mm center-to-center steel deck (Fy ≥ 230 MPa; Fu ≥ 310 MPa) installed with Hilti X-HSN 24 fasteners with 914/5 (36/5) or 914/4 (36/4) end and interior support fastener patterns1,2,3,4,5 Gauge Sidelap spacing Hilti 36/5 SLC6,7,8 900 152O.C. mm 6''mm 36'' 600 mm O.C.. 450 mm O.C. 22 300 mm O.C. 36/7 150 mm O.C. 756'' mm O.C. 152 mm 36'' 900 mm O.C. 600 mm O.C. 450 mm O.C. 20 36/9 300 mm O.C. 150 152O.C. mm 6''mm 36'' 75 mm O.C. 900 mm O.C. 600 mm O.C. 36/11 450 mm O.C. 18 300 6''mm O.C. 36'' 150 mm O.C. 75 mm O.C. 900 mm O.C. 600 mm O.C. 450 mm O.C. 16 300 mm O.C. 150 mm O.C. 75 mm O.C. Factor 914/7 4'-0" 5 4 SLSD 10.1 8.2 G' 2.3 1.7 914 mm 1-1/2'' SLSD 11.2 9.2 G' 2.3 1.7 SLSD 12.1 10.0 G' 2.3 1.7 SLSD 13.8 11.4 G' 2.4 1.7 SLSD 17.2 13.9 914/9 G' 2.4 1.7 SLSD 17.2 13.9 G' 2.4 1.8 914 mm 1-1/2'' SLSD 13.5 11.0 G' 3.5 2.6 SLSD 15.0 12.4 G' 3.6 2.6 SLSD 16.4 13.6 G' 3.6 2.7 SLSD 18.7 15.4 914/11 G' 3.7 2.7 SLSD 23.1 18.6 G' 3.8 2.8 714 mm 1-1/2'' SLSD 23.1 18.6 G' 3.8 2.8 SLSD 16.8 13.7 G' 6.4 4.8 SLSD 18.7 15.5 G' 6.5 4.9 SLSD 20.4 16.9 G' 6.6 5.0 SLSD 23.3 19.3 G' 6.8 5.1 1-1/2'' SLSD 28.8 23.1 G' 7.1 5.3 SLSD 28.8 23.1 G' 7.3 5.4 SLSD 18.6 15.3 G' 10.0 7.7 SLSD 20.8 17.2 G' 10.4 7.9 SLSD 22.8 18.9 G' 10.6 8.1 SLSD 26.0 21.5 G' 11.0 8.4 SLSD 32.0 25.6 G' 11.7 8.9 SLSD 32.0 25.6 G' 12.2 9.2 5'-0" 5 4 8.9 7.3 2.7 2.0 38 mm 10.0 8.4 2.8 2.0 11.1 9.3 2.8 2.1 12.9 10.9 2.9 2.1 16.7 13.7 2.9 2.1 16.7 13.7 3.0 2.2 38 mm 11.9 9.9 4.1 3.1 13.6 11.4 4.2 3.2 15.1 12.7 4.3 3.2 17.6 14.8 4.4 3.3 22.6 18.4 4.6 3.4 38 mm 22.6 18.4 4.7 3.4 14.9 12.4 7.3 5.5 17.0 14.3 7.5 5.7 18.9 15.9 7.7 5.9 22.1 18.5 8.0 6.1 28.2 22.8 8.5 6.4 28.2 22.8 8.8 6.6 16.6 13.8 11.1 8.6 19.0 16.0 11.6 9.1 21.1 17.8 12.0 9.4 24.7 20.7 12.7 9.8 31.4 25.3 13.7 10.5 31.4 25.3 14.5 11.0 Span (ft- in.) 6'-0" 7'-0" 8'-0" Fasteners per sheet to support 914/5 5 4 5 4 5 4 8.0 6.7 7.3 6.2 6.8 5.8 3.1 2.3 3.5152 mm 2.6 3.8 2.9 914 mm 9.2 7.8 8.6 7.4 8.1 7.0 3.2 2.4 3.6 2.7 3.9 3.0 10.3 8.8 9.7 8.4 9.3 8.1 3.3 2.4 3.7 2.7 4.0 3.1 12.3 10.5 11.8 10.2 11.4 9.9 3.3 2.5 3.8 2.8 4.2 3.1 16.3 13.5 16.1 13.4 15.9 13.3 914/7 3.4 2.5 3.9 2.9 4.4 3.3 16.3 13.5 16.1 13.4 15.9 13.3 3.5 2.6 4.0152 mm 3.0 4.5 3.3 914 mm 10.8 9.1 10.0 8.5 9.3 8.0 4.7 3.5 5.1 3.9 5.5 4.3 12.5 10.7 11.8 10.1 11.2 9.7 4.8 3.6 5.3 4.1 5.8 4.5 14.1 12.1 13.4 11.6 12.9 11.2 4.9 3.7 5.5 4.2 6.0 4.6 16.8 14.3 16.3 14.0 15.8 13.7 914/9 5.1 3.8 5.7 4.3 6.3 4.8 22.2 18.2 21.9 18.1 21.7 17.9 5.3 3.9 6.0152 mm 4.5 6.7 5.0 914 mm 22.2 18.2 21.9 18.1 21.7 17.9 5.5 4.0 6.2 4.6 6.9 5.2 13.5 11.4 12.5 10.7 11.7 10.1 8.0 6.2 8.5 6.7 8.9 7.1 15.7 13.4 14.8 12.8 14.1 12.3 8.3 6.5 9.0 7.1 9.6 7.6 17.8 15.2 16.9 14.6 16.3 14.2 914/11 8.6 6.7 9.4 7.4 10.1 8.0 21.2 18.0 20.5 17.6 20.0 17.3 152 mm 9.1 7.0 10.0 7.8 10.8 8.5 714 mm 27.7 22.6 27.4 22.5 27.2 22.3 9.7 7.4 10.8 8.3 11.9 9.2 27.7 22.6 27.4 22.5 27.2 22.3 10.2 7.7 11.4 8.7 12.6 9.7 15.1 12.7 14.0 11.9 13.1 11.3 11.8 9.4 12.3 9.9 12.7 10.4 17.6 15.0 16.6 14.3 15.8 13.8 12.6 10.0 13.3 10.7 13.9 11.4 19.9 17.0 19.0 16.4 18.3 16.0 13.2 10.4 14.1 11.3 14.8 12.1 23.7 20.1 23.0 19.7 22.4 19.4 14.0 11.1 15.2 12.2 16.2 13.1 30.9 25.1 30.6 25.0 30.3 24.8 15.5 12.0 17.0 13.4 18.4 14.7 30.9 25.1 30.6 25.0 30.3 24.8 16.5 12.7 18.4 14.3 20.1 15.8 9'-0" 5 6.3 4.1 7.7 4.3 9.0 4.4 11.1 4.6 15.7 4.8 15.7 5.0 8.8 5.8 10.7 6.2 12.4 6.4 15.5 6.8 21.5 7.3 21.5 7.6 11.1 9.3 13.5 10.1 15.7 10.7 19.6 11.5 27.0 12.8 27.0 13.7 12.4 12.9 15.2 14.3 17.7 15.4 22.0 17.0 30.1 19.6 30.1 21.6 10'-0" 4 5 5.5 6.0 3.1 4.3 38 mm 6.8 7.4 3.3 4.6 7.9 8.7 3.3 4.7 9.8 10.9 3.5 4.9 13.2 15.6 3.6 5.2 13.2 15.6 3.7 5.4 38 mm 7.6 8.3 4.6 6.1 9.4 10.3 4.8 6.6 10.9 12.1 5.0 6.9 13.5 15.2 5.2 7.3 17.8 21.3 5.5 7.9 38 mm 17.8 21.3 5.7 8.3 9.6 10.6 7.5 9.5 11.9 13.0 8.1 10.5 13.9 15.3 8.6 11.2 17.0 19.2 9.2 12.2 38 mm 22.2 26.8 10.0 13.7 22.2 26.8 10.6 14.8 10.8 11.9 10.7 13.1 13.4 14.7 11.9 14.7 15.6 17.2 12.8 16.0 19.1 21.6 14.0 17.8 24.7 29.9 15.8 20.7 24.7 29.9 17.1 23.0 4 5.2 3.3 6.5 3.5 7.7 3.6 9.6 3.8 13.1 3.9 13.1 4.0 7.3 4.8 9.1 5.1 10.7 5.4 13.3 5.6 17.8 6.0 17.8 6.3 9.3 7.8 11.6 8.5 13.6 9.1 16.8 9.8 22.2 10.8 22.2 11.5 10.4 11.0 13.0 12.3 15.3 13.3 18.9 14.8 24.7 16.9 24.7 18.4 1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses 5 mm ≤ tf ≤ 10 mm. For attachment to base steel thickness with range 3 mm ≤ tf < 5 mm, diaphragm shear values should be calculated in accordance with Section 1.1.8. 2 Tabulated LRFD diaphragm shear loads are calculated with a phi factor (Φ) of 0.65 for wind loads. To calculate LRFD values for load combinations involving earthquake, divide values in table by 0.65 and multiply by a phi factor (Φ) of 0.60. Panel buckling has been checked. 3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60.. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 31 Steel Deck Fastening Systems 1.2 X-HSN 24 for Fastening Deck to Bar Joist c Limit States Design-Factored resistance diaphragm tables for deck fasteners (Canada) Diaphragm Table 36-7 with X-HSN 24 Metric Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor, F, (mm x 10-6/N) for 38 mm deep steel nestable deck fastened w/Hilti X-HSN 24 w/screwed sidelaps (Canada only)1,2,3 No. of transverse nails per 900 mm wide deck units=7 (every flute) Span (mm) 1200 1500 1800 2100 2400 2700 3000 Sidelap Connection Deck gauge thickness Strength, SLSD #10 screw at 600 mm O.C. #10 screw at 450 mm O.C. #10 screw at 300 mm O.C. #10 screw at 150 mm O.C. 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16 6.5 7.9 10.2 12.8 6.5 7.9 10.2 12.8 8.3 10.1 13.3 16.7 11.6 14.0 18.4 23.1 Flexibility Factor, F Strength, SLSD 120 88 60 45 120 88 60 45 110 79 52 38 101 71 45 32 5.2 6.2 8.2 10.3 6.1 7.4 9.6 12.1 7.6 9.3 12.2 15.3 11.0 13.4 17.6 22.0 Flexibility Factor, F Strength, SLSD 115 88 62 49 108 81 56 43 99 73 49 37 89 64 42 30 5.1 6.1 8.1 10.1 5.8 7.1 9.3 11.6 7.2 8.7 11.4 14.3 10.7 12.9 17.0 21.3 Flexibility Factor, F Strength, SLSD 106 81 59 46 99 76 54 42 91 68 47 36 81 59 39 29 4.2 5.2 6.9 8.7 4.9 6.0 8.0 10.0 6.8 8.2 10.8 13.6 9.6 12.6 16.6 20.7 Flexibility Factor, F Strength, SLSD 106 83 62 50 99 77 56 45 86 66 46 36 75 56 38 28 4.2 5.2 6.9 8.7 4.8 5.9 7.9 9.9 6.6 7.9 10.5 13.0 7.4 9.8 15.0 20.3 Flexibility Factor, F Strength, SLSD 99 79 59 48 94 73 54 44 83 64 46 36 71 53 37 28 3.8 4.6 6.1 7.6 4.8 5.9 7.8 9.8 5.9 7.6 10.1 12.7 5.9 7.8 11.9 16.6 Flexibility Factor, F Strength, SLSD 101 82 62 51 90 71 53 43 80 62 45 36 68 51 36 27 3.9 4.7 6.2 7.8 4.3 5.3 6.9 8.7 4.7 6.2 9.6 12.3 4.7 6.2 9.6 13.5 Flexibility Factor, F 96 78 60 49 91 73 55 45 77 61 45 36 65 50 35 27 Diaphragm Table 36-4 with X-HSN 24 Metric Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor, F, (mm x 10-6/N) for 38 mm deep steel nestable deck fastened w/Hilti X-HSN 24 w/screwed sidelaps (Canada only)1,2,3 No. of transverse nails per 900 mm wide deck units=4 (every other flute) Span (mm) 1200 1500 1800 2100 2400 2700 3000 Sidelap Connection deck gauge thickness Strength, SLSD Flexibility Factor, F Strength, SLSD Flexibility Factor, F Strength, SLSD Flexibility Factor, F Strength, SLSD Flexibility Factor, F Strength, SLSD Flexibility Factor, F Strength, SLSD Flexibility Factor, F Strength, SLSD Flexibility Factor, F Diaphragm Table 36-7 with X-HSN 24 Metric #10 screw at 600 mm O.C. #10 screw at 450 mm O.C. #10 screw at 300 mm O.C. #10 screw at 150 mm O.C. 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16 4.7 5.6 7.4 9.3 4.7 5.6 7.4 9.3 6.2 7.4 9.8 12.2 8.1 9.8 12.8 16.0 595 384 210 132 595 384 210 132 578 369 197 120 567 359 188 113 3.9 4.7 6.1 7.6 4.6 5.5 7.3 9.2 5.9 7.1 9.3 11.6 7.9 9.5 12.6 15.7 500 328 186 122 487 317 176 113 474 305 166 103 462 294 156 95 4.0 4.7 6.2 7.8 4.6 5.5 7.2 9.2 5.6 6.8 8.9 11.2 7.8 9.4 12.3 15.5 425 281 161 106 415 272 154 100 405 262 145 92 392 251 135 83 3.4 4.1 5.4 6.8 4.0 4.8 6.3 7.9 5.4 6.6 8.6 10.8 7.6 9.3 12.2 15.3 383 257 152 103 372 247 143 96 355 232 130 84 342 220 120 75 3.5 4.2 5.6 7.1 4.0 4.8 6.3 8.0 5.3 6.3 8.5 10.6 7.6 9.2 12.1 15.2 340 230 137 94 332 222 130 88 318 209 119 78 304 197 108 68 3.1 3.8 4.9 6.2 4.0 4.9 6.5 8.1 5.2 6.2 8.2 10.3 7.5 9.2 12.0 15.0 318 218 133 93 301 203 120 82 289 192 110 73 275 179 99 63 3.2 3.9 5.2 6.6 3.6 4.5 5.9 7.4 5.1 6.2 8.1 10.2 7.5 9.0 12.0 14.9 290 365 123 86 283 193 117 81 266 177 103 69 252 165 92 59 Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor, F, (mm x 10-6/N) for 38 mm deep steel deck fastened w/Hilti X-HSN 24 w/button punch sidelaps (Canada only)1,2,3 No. of transverse nails per 900 mm wide deck units=7 (every flute) Span (mm) 1200 1500 1800 2100 2400 2700 3000 Sidelap Connection deck gauge thickness Strength, SLSD Flexibility Factor, F Strength, SLSD Flexibility Factor, F Strength, SLSD Flexibility Factor, F Strength, SLSD Flexibility Factor, F Strength, SLSD Flexibility Factor, F Strength, SLSD Flexibility Factor, F Strength, SLSD Flexibility Factor, F Button Punch 600 mm O.C. Button Punch 450 mm O.C. Button Punch 300 mm O.C. Button Punch 150 mm O.C. 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16 5.8 7.1 9.5 12.1 5.8 7.1 9.5 12.1 6.5 8.1 11.2 14.8 7.8 10.0 14.3 19.6 129 96 67 51 129 96 67 51 126 94 65 50 122 90 62 47 4.6 5.6 7.5 9.8 4.8 6.0 8.3 10.9 5.5 6.9 9.9 13.2 6.9 8.9 13.2 18.2 126 97 71 56 125 96 69 55 122 94 67 53 116 88 63 49 4.0 4.9 6.9 9.2 4.2 5.4 7.5 10.1 4.8 6.1 8.8 12.1 6.2 8.2 12.2 17.3 126 100 75 61 124 98 73 59 121 95 71 57 114 89 65 52 3.4 4.2 5.9 7.8 3.6 4.6 6.5 8.7 4.2 5.5 8.1 11.3 5.8 7.8 11.6 16.6 130 105 81 66 128 103 79 65 122 98 75 61 113 90 67 55 3.2 4.0 5.6 7.5 3.3 4.2 6.1 8.3 3.9 5.1 7.5 10.7 5.4 7.3 11.2 16.0 133 109 85 71 130 107 83 69 125 102 79 66 113 91 70 57 2.7 3.5 4.9 6.6 3.1 4.0 5.8 8.0 3.6 4.7 7.2 10.1 5.2 6.9 10.8 15.6 139 115 92 77 134 111 88 74 128 106 83 70 114 93 72 60 2.6 3.3 4.8 6.6 2.7 3.5 5.2 7.2 3.4 4.5 6.8 9.8 4.9 6.7 10.5 15.3 143 120 96 81 140 118 94 80 131 110 87 73 115 95 75 62 1 The ratio of span of deck unit to average length of sheet is taken to be 1/3. 2 Diaphragm loads are based on steel decks having an average ultimate tensile strength of 55 ksi. 3 Values shown calculated in accordance with SDI equations using a φ factor of 0.5 for LSD for all load conditions. 32 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 Steel Deck Fastening Systems X-HSN 24 for Fastening Deck to Bar Joist 1.2 c Limit States Design-Factored resistance diaphragm tables for deck fasteners (Canada) Diaphragm Table 36-4 with X-HSN 24 Metric Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor, F, (mm x 10-6/N) for 38 mm deep steel deck fastened w/Hilti X-HSN 24 w/button punch sidelaps (Canada only)1,2,3 No. of transverse nails per 900 mm wide deck units=4 (every other flute) Span (mm) 1200 1500 1800 2100 2400 2700 3000 Sidelap Connection Deck gauge thickness Strength, SLSD Button Punch 600 mm O.C. Button Punch 450 mm O.C. Button Punch 300 mm O.C. Button Punch 150 mm O.C. 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16 4.1 4.3 5.7 7.4 3.5 4.3 5.7 7.4 4.0 5.0 7.0 9.3 4.8 6.2 8.9 12.0 Flexibility Factor, F Strength, SLSD 612 399 224 144 612 399 224 144 607 395 220 141 599 388 214 135 3.3 4.0 5.5 7.2 3.5 4.5 6.2 8.1 4.1 5.2 7.4 10.0 5.3 6.8 9.9 13.6 Flexibility Factor, F Strength, SLSD 521 348 203 137 518 345 201 134 513 340 196 130 502 330 188 123 2.9 3.6 5.2 6.9 3.2 4.1 5.9 7.9 3.6 4.7 6.9 9.4 4.9 6.5 9.5 13.2 Flexibility Factor, F Strength, SLSD 462 315 190 132 459 311 188 130 452 306 183 125 438 293 172 116 2.5 3.2 4.5 6.0 2.7 3.8 4.9 6.8 3.3 4.5 6.5 8.9 4.7 6.1 9.2 12.9 Flexibility Factor, F Strength, SLSD 426 297 186 134 422 293 183 131 412 283 175 124 394 268 161 111 2.4 2.9 4.3 6.0 2.5 3.5 4.8 6.7 3.1 4.1 6.2 8.6 4.5 5.9 8.9 12.7 Flexibility Factor, F Strength, SLSD 398 282 182 134 394 278 179 131 383 268 170 123 362 249 154 109 2.0 2.6 3.8 5.3 2.4 3.4 4.7 6.6 2.9 3.9 6.0 8.3 4.2 5.8 8.8 12.5 Flexibility Factor, F Strength, SLSD 382 276 184 139 373 268 177 132 361 257 168 124 337 236 149 107 2.0 2.6 3.8 5.3 2.1 3.2 4.2 6.0 2.7 3.6 5.8 8.1 4.1 5.6 8.7 12.3 Flexibility Factor, F 367 393 183 140 362 265 180 137 346 250 166 125 318 225 145 106 Diaphragm Table 24-5 with X-HSN 24 Metric Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor, F, (mm x 10-6/N) for 75 mm deep steel deck fastened with Hilti X-HSN 24 w/button punch sidelaps (Canada only)1, 2, 3 No. of transverse nails per 600 mm wide deck units=5 (every flute) Span (mm) 2400 2700 1800 3300 3600 3900 4200 Sidelap Connection Deck gauge thickness Strength, SLSD Flexibility Factor, F Strength, SLSD Flexibility Factor, F Strength, SLSD Flexibility Factor, F Strength, SLSD Flexibility Factor, F Strength, SLSD Flexibility Factor, F Strength, SLSD Flexibility Factor, F Strength, SLSD Flexibility Factor, F Button Punch 600 mm O.C. Button Punch 450 mm O.C. Button Punch 300 mm O.C. Button Punch 150 mm O.C. 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16 2.0 2.6 3.7 5.2 2.1 2.8 4.2 5.8 2.6 3.5 5.4 7.8 3.9 5.4 8.8 12.9 281 227 173 143 275 222 169 139 262 209 158 130 235 185 137 111 1.7 2.2 3.3 4.5 2.0 2.6 4.0 5.7 2.4 3.3 5.1 7.5 3.7 5.2 8.5 12.6 290 238 185 154 279 227 176 146 264 214 165 136 233 186 140 115 1.6 2.1 3.2 4.5 1.7 2.3 3.5 5.1 2.3 3.1 4.9 7.2 3.6 5.0 8.2 12.4 295 244 192 161 289 238 187 157 268 220 171 143 233 188 143 118 1.4 1.9 2.9 4.1 1.7 2.2 3.5 5.0 2.1 2.9 4.7 7.0 3.4 4.8 8.0 12.2 307 257 205 173 293 245 194 164 272 225 177 149 233 189 146 121 1.4 1.9 2.9 4.1 1.6 2.2 3.4 5.0 2.0 2.8 4.5 6.8 3.3 4.7 7.9 12 312 263 211 180 299 251 201 170 277 231 183 155 233 191 149 124 1.2 1.7 2.6 3.8 1.4 2.0 3.1 4.6 1.9 2.7 4.4 6.6 3.2 4.6 7.8 11.9 325 276 224 191 311 263 212 181 282 237 189 160 234 193 152 127 1.2 1.6 2.6 3.8 1.4 1.9 3.1 4.6 1.9 2.6 4.3 6.5 3.2 4.5 7.6 11.8 331 282 230 197 316 269 218 186 287 242 195 166 235 195 154 129 1 The ratio of span of deck unit to average length of sheet is taken to be 1/3. 2 Diaphragm loads are based on steel decks having an average ultimate tensile strength of 55 ksi. 3 Values shown calculated in accordance with SDI equations using a φ factor of 0.5 for LSD for all load conditions. Note: Reference pages 30-31 for generally higher diaphragm capacities with Hilti Sidelap Connectors (SLC). Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 33 Steel Deck Fastening Systems 1.2 X-HSN 24 for Fastening Deck to Bar Joist 1.2.4 Ordering Information DX 860-HSN Decking System Tools Description DX 860-HSN Stand-Up Decking Tool Accessories Description HSN Piston and Brake Spares Pack Notes Qty Use-on-Demand service provides daily rental 1 pcs Notes Qty Replacement piston and brake for DX 860-HSN 1 pcs Fasteners (Combos with 40-strip Cartridges) Description Notes Qty X-HSN 24 bulk fastener/cartridge combo X-HSN 24 pallet fastener/cartridge combo 1/8" (3 mm) ≤ tf ≤ 3/8" (10 mm) 1/8" (3 mm) ≤ tf ≤ 3/8" (10 mm) 2,000 pcs 32,000 pcs Notes Qty DX 460-SM Decking System Tools Description DX 460-SM Hand Held Decking Tool 1 pcs Accessories Description Notes Qty Magazine X-SM Piston X-AP PSM Buffer (reinforced) X-460-B Replacement magazine for DX 460-SM Replacement piston for DX 460-SM Replacement buffer for DX-460-SM 1 pcs 1 pcs 1 pcs Fasteners (Combos with 10-strip cartridges for DX 460-SM) Description Notes Qty X-HSN 24 bulk fastener/cartridge combo X-HSN 24 pallet fastener/cartridge combo 1,000 pcs 32,000 pcs 3/16" (5 mm) ≤ tf ≤ 3/8" (10 mm) 3/16" (5 mm) ≤ tf ≤ 3/8" (10 mm) 34 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 Steel Deck Fastening Systems X-ENP-19 for Fastening Deck to Structural Steel 1.3 1.3.1 Product Description The Hilti structural steel deck fastening system consists of powder-actuated tools which are primarily used with one fastener: the X-ENP-19 L15, which is available either collated or non-collated. For most structural steel decking jobs, the tool of choice is the DX 860-ENP-L tool. This self-contained stand up decking tool is powered by 0.27 caliber long cartridges, which are loaded into the tool in strips of 40. The cartridges drive the X-ENP-19 L15 MXR fastener (collated version) into almost any type of steel deck and base steel thicknesses greater than or equal to 1/4". These fasteners are available in collated strips of 10. Four of these strips are loaded into the DX 860-ENP-L tool along with the cartridge strip, and enable the operator to fasten at a rate of up to 1,000 quality fastenings per hour. Fastener plating 5 µm Zinc1 Nominal fastener hardness 58 HRC 1.3.3 Technical Data Allowable pullout loads for attachments to steel base material lb (kN)1, 2, 3 X-ENP-19 L15 1 2 3 4 1/4 905 (4.03) Material Specifications 1.3.3 Technical Data 1.3.4 Ordering Information X-ENP-19 L15 MX and MXR X-ENP-19 L15 Approvals/Listings 1 ASTM B633, SC 1, Type III. Reference Section 2.3.3.1 of Hilti North American Product Technical Guide Volume 1: Direct Fastening for more information. Fastener 1.3.2 Hilti X-ENP-19 steel deck fasteners comply with ANSI/SDI RD1.0, C1.0 and NC1.0 standards. Fastener material Carbon Steel X-ENP-19 L15 Product Description Other tools include the hand held DX 76-MX, a semi-automatic magazine tool. Other configurations of the DX 76 include a single fastener guide variation of the tool for miscellaneous use. 1.3.2 Material Specifications Fastener 1.3.1 Base material thickness (in.) 3/8 1/2 4 1125 (5.00) 1010 (4.49) ≥ 5/8 4 965 (4.29) These values represent testing performed in ASTM A36 plate steel. The values must be compared with allowable tensile pullover values. Allowable values based on safety factor of 5.0. Allowable values are based on minimum 1/2" penetration depth through or into base steel. For 3/8" penetration depth into 1/2" and thicker steels, reduce the allowable load capacity to 635 lb (2.79 kN). ICC-ES (International Code Council) ESR-2776, ESR-2197, ESR-1116, ESR-1169, ESR-1414 COLA (City of Los Angeles) RR 25877, RR 25296 FM (Factory Mutual) For attaching Class 1 Steel Roof Decks with 1-60 and 1-90 wind uplift ratings. Listed for higher wind uplift ratings with FM Approved Lightweight Insulating Concrete Roof Deck Assemblies. Refer to FM RoofNav for specific assembly listings. UL (Underwriters Laboratories) Fasteners for attaching steel roof deck (uplift and fire classification) ABS (American Bureau of Shipping) Allowable pullover and shear bearing loads for attaching steel deck 1,2,3 Steel deck gauge (in.) Fastener X-ENP-19 L15 16 (0.0598) Tension lb (kN) Shear lb (kN) 18 (0.0474) Tension lb (kN) Shear lb (kN) 20 (0.0358) Tension lb (kN) Shear lb (kN) 22 (0.0295) Tension lb (kN) Shear lb (kN) 24 (0.0239) Tension lb (kN) Shear lb (kN) 26 (0.0179) Tension lb (kN) Shear lb (kN) 940 1050 875 840 755 640 665 535 400 440 185 335 (4.14) (4.62) (3.85) (3.70) (3.32) (2.82) (2.93) (2.35) (1.78) (1.94) (0.81) (1.47) 1 Minimum base steel thickness must be greater than or equal to 1/4" (6 mm). 2 Allowable values are based on a safety factor of 3.0. 3 Loads based on ASTM A1008, or minimum ASTM A653 SQ33 steel deck. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 35 6'' 1-1/2'' 36'' 152 mm 36'' 1-1/2'' 914 mm 38 mm Steel Deck Fastening Systems 1.3 X-ENP-19 for Fastening Deck to Structural Steel 36/9 6'' 36/7 1-1/2'' 36'' 6'' 152 mm 36'' 914/9 1-1/2'' 914 mm 38 mm Allowable Stress Design (ASD)-Allowable diaphragm shears, SASD, (plf) and stiffness factors, G', (kips/in.) for standard 1-1/2" deep flutes, 6" center-to-center steel deck (Fy ≥ 33 ksi; Fu ≥ 45 ksi) installed with Hilti X-ENP-19 L15 fasteners with 36/9 or 36/7 end and interior support fastener patterns1,2,3,4,5 Gauge Sidelap spacing Hilti SLC6,7,8 36" O.C. 24" O.C. 18" O.C. 22 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 20 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 18 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 16 12" O.C. 6" O.C. 3" O.C. Factor 36/11 4'-0" 9 SASD 804 6'' G' 55.7 36'' SASD 861 G' 56.2 SASD 915 G' 56.8 SASD 1016 G' 57.5 SASD 1263 G' 59.2 SASD 1568 G' 61.0 SASD 1038 G' 78.5 SASD 1117 G' 79.5 SASD 1193 G' 80.0 SASD 1333 G' 81.8 SASD 1666 G' 84.8 SASD 2050 G' 88.5 SASD 1254 G' 123.5 SASD 1352 G' 126.6 SASD 1446 G' 128.2 SASD 1617 G' 131.6 SASD 2023 G' 138.9 SASD 2484 G' 147.1 SASD 1277 G' 172.4 SASD 1382 G' 175.4 SASD 1481 G' 178.6 SASD 1662 G' 185.2 SASD 2082 G' 196.1 SASD 2542 G' 212.8 7 561 52.8 623 53.7 683 54.3 793 55.7 1058 58.1 1362 60.2 731 73.3 819 74.9 902 76.3 1055 78.5 1409 83.0 1784 87.0 886 113.6 994 116.3 1097 119.0 1285 123.5 1715 133.3 2163 144.9 908 153.8 1023 158.7 1132 163.9 1330 172.4 1773 188.7 2214 208.3 5'-0" 9 7 688 485 61.5 57.5 1-1/2'' 750 550 62.5 59.0 808 613 63.3 60.2 919 730 64.6 62.3 1192 1014 67.1 66.1 1532 1341 69.9 69.4 892 636 84.6 77.7 979 728 86.2 80.2 1061 815 87.7 82.6 1214 978 89.9 85.9 1583 1358 94.7 92.5 2012 1763 100.0 99.0 1079 771 128.4 115.0 1186 885 131.6 120.6 1288 993 135.1 123.5 1476 1193 139.3 131.0 1926 1655 149.5 144.7 2440 2138 161.3 158.7 1102 793 172.4 151.5 1216 914 178.6 158.7 1324 1029 181.8 166.7 1523 1239 192.3 175.4 1989 1716 208.3 200.0 2501 2192 227.3 222.2 Span (ft- in.) 6'-0" 7'-0" 8'-0" Fasteners per sheet to support 36/9 9 7 9 7 9 7 595 426 525 383 473 352 6'' 152 mm 65.6 60.5 68.3 62.4 69.9 63.7 36'' 670 499 601 459 549 427 67.0 62.7 70.2 65.3 72.5 67.1 732 564 675 528 624 500 68.0 64.5 71.9 67.6 74.6 69.9 849 685 796 652 755 627 70.2 67.4 74.5 71.4 78.1 74.6 1140 982 1101 958 1070 36/11 940 74.1 72.6 80.0 78.1 84.7 82.6 1505 1327 1485 1316 1188 1188 6'' 78.1 77.5 84.7 84.0 90.1 89.3 36'' 783 566 695 513 629 472 88.2 80.0 90.1 81.0 91.0 81.2 880 664 803 617 737 580 90.5 83.5 93.2 85.4 94.8 86.6 967 755 896 710 841 676 92.6 86.2 96.2 89.3 98.0 90.9 1129 923 1064 883 1014 852 95.8 91.2 100.2 95.1 103.5 98.1 1523 1321 1477 1294 1441 1273 102.5 100.0 108.7 106.1 113.8 111.0 1983 1748 1962 1737 1547 1547 108.7 107.5 117.6 116.3 123.5 122.0 956 692 851 628 772 580 129.6 114.7 129.1 113.2 127.5 111.2 1068 809 979 753 906 710 133.9 120.9 134.5 120.8 134.1 120.0 1175 921 1090 868 1025 827 137.0 126.6 138.9 128.2 140.8 128.2 1374 1128 1298 1080 1238 1044 144.3 135.2 147.4 138.0 149.4 139.8 1855 1612 1801 1581 1759 1556 157.7 152.6 163.9 158.7 168.7 163.4 2407 2121 2383 2108 2219 2099 172.4 169.5 181.8 178.6 188.7 185.2 978 713 881 654 801 605 170.3 147.8 166.5 143.5 162.2 139.1 1098 838 1010 782 942 740 177.0 157.2 174.7 154.4 171.7 151.4 1212 957 1128 904 1063 864 181.8 166.7 181.8 163.9 178.6 161.3 1423 1176 1347 1129 1289 1093 193.4 179.1 194.4 179.9 194.4 180.1 1922 1676 1870 1646 1830 1622 215.3 206.9 220.4 212.0 224.1 215.8 2472 2177 2450 2166 2432 2157 238.1 232.6 250.0 243.9 256.4 250.0 9'-0" 914/11 10'-0" 9 7 9 436 329 408 71.4 64.1 71.9 1-1/2'' 714 mm 512 404 483 74.1 68.5 75.2 587 478 558 76.9 71.9 78.1 723 607 697 80.6 77.5 83.3 938 926 760 88.5 87.0 91.7 938 938 760 95.2 94.3 100.0 1-1/2'' 578 441 541 90.9 81.3 90.9 686 549 649 96.2 87.0 96.2 793 649 757 100.0 92.6 101.0 975 828 942 106.4 100.0 107.5 1222 1222 990 117.6 114.9 122.0 1222 1222 990 129.9 128.2 135.1 710 542 661 125.5 109.1 123.5 844 676 795 133.0 118.9 131.6 973 795 928 138.9 126.6 138.9 1191 1015 1152 150.6 141.0 151.5 1725 1537 1420 172.4 167.2 175.4 1753 1753 1420 196.1 192.3 200.0 739 567 690 157.8 135.0 153.5 883 706 833 168.4 148.5 165.2 1011 832 969 178.6 161.3 175.4 1242 1064 1204 193.9 179.8 193.0 1797 1604 1771 226.8 218.8 228.9 2191 2150 1775 263.2 256.4 263.2 7 311 64.5 38 mm 386 69.4 461 73.5 591 79.4 760 90.1 760 99.0 418 80.6 526 87.7 627 93.5 808 102.0 990 119.0 990 133.3 512 106.4 646 117.6 769 126.6 991 140.8 1420 169.5 1420 196.1 537 131.1 679 145.7 806 158.7 1041 179.4 1589 221.1 1775 263.2 1 Tabulated diaphragm shear values are for attachment of steel deck to a base steel thickness, tf ≥ 1/4". 2 Tabulated ASD diaphragm shear loads are calculated with a safety factor (Ω) of 2.35 for wind loads. To calculate ASD values for load combinations involving earthquake, multiply values in table by 2.35 and divide by a safety factor (Ω) of 2.50. Panel buckling has been checked. 3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60. 36 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 1-1/2'' 36'' 152 mm 36'' 1-1/2'' 914 mm 38 mm Steel Deck Fastening Systems X-ENP-19 for Fastening Deck to Structural Steel 1.3 36/4 36/5 6'' 1-1/2'' 36'' 6'' 152 mm 36'' 914/5 1-1/2'' 914 mm 38 mm Allowable Stress Design (ASD)-Allowable diaphragm shears, SASD, (plf) and stiffness factors, G', (kips/in.) for standard 1-1/2" deep flutes, 6" center-to-center steel deck (Fy ≥ 33 ksi; Fu ≥ 45 ksi) installed with Hilti X-ENP-19 L15 fasteners with 36/5 or 36/4 end and interior support fastener patterns1,2,3,4,5 Gauge Sidelap spacing Hilti SLC6,7,8 36" O.C. 24" O.C. 18" O.C. 22 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 20 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 18 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 16 12" O.C. 6" O.C. 3" O.C. Factor 36/7 4'-0" 5 SASD 504 6'' G' 13.6 36'' SASD 557 G' 13.6 SASD 605 G' 13.7 SASD 688 G' 13.8 SASD 36/9 862 G' 14.0 SASD 862 6'' G' 14.1 36'' SASD 656 G' 21.1 SASD 729 G' 21.2 SASD 795 G' 21.4 SASD 36/11 908 G' 21.6 SASD 1130 6'' G' 22.0 36'' SASD 1130 G' 22.3 SASD 795 G' 38.8 SASD 884 G' 39.2 SASD 965 G' 39.7 SASD 1103 G' 40.3 SASD 1370 G' 41.5 SASD 1370 G' 42.4 SASD 813 G' 62.1 SASD 908 G' 63.3 SASD 993 G' 64.1 SASD 1136 G' 65.8 SASD 1404 G' 68.5 SASD 1404 G' 70.9 4 410 9.9 458 9.9 501 10.0 572 10.0 700 10.1 700 10.2 536 15.4 602 15.5 660 15.6 753 15.8 913 16.0 913 16.2 650 28.8 731 29.2 801 29.5 914 30.0 1105 30.8 1105 31.3 666 46.9 751 47.8 825 48.8 940 49.8 1128 51.8 1128 53.2 5'-0" 5 4 442 365 16.3 11.9 1-1/2'' 499 418 16.4 12.0 552 465 16.6 12.1 644 544 16.8 12.2 837 688 17.1 12.4 837 688 17.3 12.6 1-1/2'' 579 481 24.9 18.4 659 554 25.3 18.7 731 618 25.5 18.9 856 721 25.9 19.1 1103 899 26.6 19.6 1-1/2'' 1103 899 27.1 19.9 703 584 44.6 33.7 801 673 45.5 34.4 890 751 46.3 35.0 1042 877 47.4 35.8 1339 1089 49.3 37.1 1339 1089 51.0 38.2 722 601 69.4 53.5 825 695 71.4 55.2 919 776 73.0 56.5 1077 905 75.8 58.1 1376 1114 80.0 61.3 1376 1114 84.0 64.1 Span (ft- in.) 6'-0" 7'-0" 8'-0" Fasteners per sheet to support 36/5 5 4 5 4 5 4 398 333 365 309 336 288 6'' 152 mm 18.8 13.8 21.0 15.6 23.0 36''17.2 458 389 428 367 404 351 19.0 14.0 21.4 15.9 23.5 17.6 514 440 485 420 463 405 19.2 14.2 21.7 16.1 23.9 17.9 613 524 589 509 570 497 19.5 14.4 22.1 16.4 24.6 18.3 819 679 806 672 795 36/7 666 20.0 14.7 22.8 16.8 25.4 18.9 819 679 806 672 795 666 6'' 152 mm 20.4 14.9 23.3 17.1 26.1 19.3 36'' 525 441 484 411 452 388 28.3 21.2 31.3 23.6 33.7 25.7 608 519 571 492 541 472 28.8 21.6 32.1 24.2 34.8 26.6 685 587 651 564 624 546 29.2 21.9 32.7 24.6 35.7 27.2 819 698 790 681 768 36/9 667 29.9 22.3 33.6 25.2 36.9 28.0 1084 890 1069 883 1058 877 6'' 152 mm 30.9 22.9 35.0 26.2 38.8 29.2 36'' 1084 890 1069 883 1058 877 31.7 23.4 36.1 26.8 40.2 30.1 637 536 588 501 551 474 49.3 37.8 53.2 41.2 56.2 44.0 741 632 695 600 661 576 50.8 38.9 55.2 42.8 58.8 46.1 835 715 794 688 762 36/11 666 51.8 39.7 56.8 44.1 61.0 47.8 998 850 964 830 938 814 6'' 53.8 41.0 59.2 45.7 64.1 50.0 36'' 1317 1079 1300 1070 1287 1064 56.5 42.9 63.3 48.4 69.0 53.5 1317 1079 1300 1070 1287 1064 58.8 44.4 66.2 50.5 73.0 56.2 657 554 608 519 570 492 74.6 58.6 78.7 62.4 81.3 65.4 766 654 721 624 687 599 77.5 61.0 82.6 65.7 86.2 69.6 865 741 825 715 794 694 80.0 62.9 86.2 68.5 90.1 73.0 1035 880 1002 860 977 845 84.0 65.7 90.9 72.1 97.1 77.8 1355 1105 1340 1097 1328 1091 90.1 70.2 99.0 78.2 107.5 85.5 1355 1105 1340 1097 1328 1091 96.2 74.1 106.4 82.6 116.3 91.7 9'-0" 914/7 10'-0" 5 4 5 315 272 298 24.8 18.7 1-1/2'' 26.3 914 mm 385 337 370 25.5 19.3 27.3 446 393 431 26.0 19.6 28.0 555 487 542 26.8 20.2 29.0 787 760 914/9662 28.0 20.9 30.4 787 662 760 28.8 21.4 31.4 1-1/2'' 914 mm 423 370 402 35.8 27.7 37.7 518 455 499 37.3 28.7 39.5 602 531 585 38.5 29.5 41.0 750 736 914/11656 40.0 30.6 42.9 1048 872 990 42.4 32.2 1-1/2'' 45.9 714 mm 1048 872 990 44.1 33.2 47.8 521 452 493 58.5 46.4 60.2 633 556 610 61.7 49.1 64.5 736 649 715 64.5 51.0 67.6 917 801 900 68.5 54.0 71.9 1-1/2'' 1276 1059 1267 74.6 58.3 79.4 1276 1059 1267 79.4 61.3 85.5 540 470 516 83.3 67.7 84.0 659 580 637 89.3 72.9 91.7 768 677 748 94.3 76.9 97.1 957 833 940 102.0 82.8 106.4 1318 1087 1310 114.9 92.1 120.5 1318 1087 1310 125.0 99.0 133.3 4 260 20.1 38 mm 326 20.8 383 21.3 479 21.9 658 22.8 658 23.5 38 mm 354 29.4 442 30.8 519 31.7 647 33.0 868 35.0 38 mm 868 36.2 434 48.3 540 51.5 635 54.1 790 57.5 1054 62.9 1054 66.7 452 69.5 565 75.6 663 80.0 823 87.2 1083 98.2 1083 106.4 1 Tabulated diaphragm shear values are for attachment of steel deck to a base steel thickness, tf ≥ 1/4". 2 Tabulated ASD diaphragm shear loads are calculated with a safety factor (Ω) of 2.35 for wind loads. To calculate ASD values for load combinations involving earthquake, multiply values in table by 2.35 and divide by a safety factor (Ω) of 2.50. Panel buckling has been checked. 3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 37 6'' 1-1/2'' 36'' 152 mm 36'' 1-1/2'' 914 mm 38 mm Steel Deck Fastening Systems 1.3 X-ENP-19 for Fastening Deck to Structural Steel 36/7 36/9 6'' 1-1/2'' 36'' 6'' 152 mm 36'' 914/9 1-1/2'' 914 mm 38 mm Load Resistance Factor Design (LRFD) – Factored resistance diaphragm shears, SLRFD, (plf) and stiffness factors, G', (kips/in.) for standard 1-1/2" deep flutes, 6" center-to-center steel deck (Fy ≥ 33 ksi; Fu ≥ 45 ksi) installed with Hilti X-ENP-19 L15 fasteners with 36/9 or 36/7 end and interior support fastener patterns1,2,3,4,5 Gauge Sidelap spacing Hilti SLC6,7,8 36" O.C. 24" O.C. 18" O.C. 22 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 20 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 18 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 16 12" O.C. 6" O.C. 3" O.C. Factor 36/11 4'-0" 9 SLRFD 1322 6'' G' 55.7 36''1415 SLRFD G' 56.2 SLRFD 1504 G' 56.8 SLRFD 1669 G' 57.5 SLRFD 2076 G' 59.2 SLRFD 2577 G' 61.0 SLRFD 1705 G' 78.5 SLRFD 1836 G' 79.5 SLRFD 1961 G' 80.0 SLRFD 2190 G' 81.8 SLRFD 2737 G' 84.8 SLRFD 3369 G' 88.5 SLRFD 2060 G' 123.5 SLRFD 2222 G' 126.6 SLRFD 2375 G' 128.2 SLRFD 2658 G' 131.6 SLRFD 3325 G' 138.9 SLRFD 4082 G' 147.1 SLRFD 2098 G' 172.4 SLRFD 2270 G' 175.4 SLRFD 2433 G' 178.6 SLRFD 2731 G' 185.2 SLRFD 3422 G' 196.1 SLRFD 4177 G' 212.8 7 922 52.8 1024 53.7 1122 54.3 1303 55.7 1739 58.1 2238 60.2 1202 73.3 1346 74.9 1483 76.3 1734 78.5 2315 83.0 2932 87.0 1456 113.6 1634 116.3 1803 119.0 2111 123.5 2818 133.3 3554 144.9 1492 153.8 1681 158.7 1860 163.9 2185 172.4 2913 188.7 3638 208.3 5'-0" 9 7 1131 796 61.5 57.5 1-1/2'' 1232 904 62.5 59.0 1328 1006 63.3 60.2 1509 1199 64.6 62.3 1959 1666 67.1 66.1 2517 2204 69.9 69.4 1466 1044 84.6 77.7 1608 1196 86.2 80.2 1743 1340 87.7 82.6 1995 1607 89.9 85.9 2601 2231 94.7 92.5 3305 2897 100.0 99.0 1774 1267 128.4 115.0 1949 1454 131.6 120.6 2116 1632 135.1 123.5 2426 1960 139.3 131.0 3165 2719 149.5 144.7 4009 3514 161.3 158.7 1811 1302 172.4 151.5 1998 1502 178.6 158.7 2176 1691 181.8 166.7 2503 2037 192.3 175.4 3269 2820 208.3 200.0 4110 3603 227.3 222.2 Span (ft- in.) 6'-0" 7'-0" 8'-0" Fasteners per sheet to support 36/9 9 7 9 7 9 7 977 699 863 630 778 578 152 mm 65.6 60.5 68.3 62.4 6'' 69.9 63.7 36'' 1101 820 987 754 902 702 67.0 62.7 70.2 65.3 72.5 67.1 1203 926 1110 867 1025 822 68.0 64.5 71.9 67.6 74.6 69.9 1394 1126 1308 1071 1241 1030 70.2 67.4 74.5 71.4 78.1 74.6 1874 1614 1809 1575 1759 1545 36/11 74.1 72.6 80.0 78.1 84.7 82.6 2473 2181 2440 2163 1900 1900 78.1 77.5 84.7 84.0 6'' 90.1 89.3 36'' 1286 930 1142 842 1034 776 88.2 80.0 90.1 81.0 91.0 81.2 1445 1091 1319 1014 1211 953 90.5 83.5 93.2 85.4 94.8 86.6 1588 1240 1472 1167 1382 1111 92.6 86.2 96.2 89.3 98.0 90.9 1855 1517 1749 1451 1667 1401 95.8 91.2 100.2 95.1 103.5 98.1 2502 2171 2427 2126 2368 2092 102.5 100.0 108.7 106.1 113.8 111.0 3259 2873 3224 2854 2475 2475 108.7 107.5 117.6 116.3 123.5 122.0 1570 1136 1399 1032 1268 953 129.6 114.7 129.1 113.2 127.5 111.2 1754 1329 1609 1237 1488 1167 133.9 120.9 134.5 120.8 134.1 120.0 1930 1513 1792 1426 1684 1359 137.0 126.6 138.9 128.2 140.8 128.2 2258 1854 2133 1775 2035 1715 144.3 135.2 147.4 138.0 149.4 139.8 3048 2649 2960 2597 2891 2557 157.7 152.6 163.9 158.7 168.7 163.4 3955 3486 3915 3465 3550 3448 172.4 169.5 181.8 178.6 188.7 185.2 1607 1171 1448 1074 1317 994 170.3 147.8 166.5 143.5 162.2 139.1 1804 1377 1659 1286 1547 1216 177.0 157.2 174.7 154.4 171.7 151.4 1991 1573 1853 1486 1747 1419 181.8 166.7 181.8 163.9 178.6 161.3 2338 1932 2214 1855 2118 1796 193.4 179.1 194.4 179.9 194.4 180.1 3158 2753 3073 2704 3007 2666 215.3 206.9 220.4 212.0 224.1 215.8 4062 3577 4025 3559 3996 3544 238.1 232.6 250.0 243.9 256.4 250.0 9'-0" 914/11 10'-0" 9 7 9 717 540 670 71.4 64.1 71.9 1-1/2'' 714 mm 841 664 794 74.1 68.5 75.2 965 786 918 76.9 71.9 78.1 1188 997 1145 80.6 77.5 83.3 1501 1501 1216 88.5 87.0 91.7 1501 1501 1216 95.2 94.3 100.0 1-1/2'' 949 725 889 90.9 81.3 90.9 1126 902 1066 96.2 87.0 96.2 1303 1067 1243 100.0 92.6 101.0 1602 1360 1548 106.4 100.0 107.5 1956 1956 1584 117.6 114.9 122.0 1956 1956 1584 129.9 128.2 135.1 1167 891 1086 125.5 109.1 123.5 1387 1111 1306 133.0 118.9 131.6 1599 1306 1525 138.9 126.6 138.9 1957 1667 1893 150.6 141.0 151.5 2805 2525 2272 172.4 167.2 175.4 2805 2805 2272 196.1 192.3 200.0 1215 932 1133 157.8 135.0 153.5 1451 1161 1369 168.4 148.5 165.2 1662 1367 1593 178.6 161.3 175.4 2041 1749 1978 193.9 179.8 193.0 2954 2635 2840 226.8 218.8 228.9 3506 3506 2840 263.2 256.4 263.2 7 511 64.5 38 mm 635 69.4 757 73.5 970 79.4 1216 90.1 1216 99.0 688 80.6 865 87.7 1031 93.5 1328 102.0 1584 119.0 1584 133.3 842 106.4 1061 117.6 1263 126.6 1628 140.8 2272 169.5 2272 196.1 883 131.1 1116 145.7 1324 158.7 1711 179.4 2611 221.1 2840 263.2 1 Tabulated diaphragm shear values are for attachment of steel deck to a base steel thickness, tf ≥ 1/4". 2 Tabulated LRFD diaphragm shear loads are calculated with a phi factor (Φ) of 0.70 for wind loads. To calculate LRFD values for load combinations involving earthquake, divide values in table by 0.70 and multiply by a phi factor (Φ) of 0.65. Panel buckling has been checked. 3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60. 38 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 1-1/2'' 36'' 152 mm 36'' 1-1/2'' 914 mm 38 mm Steel Deck Fastening Systems X-ENP-19 for Fastening Deck to Structural Steel 1.3 36/4 36/5 6'' 1-1/2'' 36'' 6'' 152 mm 36'' 914/5 1-1/2'' 914 mm 38 mm Load Resistance Factor Design (LRFD) – Factored resistance diaphragm shears, SLRFD, (plf) and stiffness factors, G', (kips/in.) for standard 1-1/2" deep flutes, 6" center-to-center steel deck (Fy ≥ 33 ksi; Fu ≥ 45 ksi) installed with Hilti X-ENP-19 L15 fasteners with 36/5 or 36/4 end and interior support fastener patterns1,2,3,4,5 Gauge Sidelap spacing Hilti SLC6,7,8 36" O.C. 24" O.C. 18" O.C. 22 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 20 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 18 12" O.C. 6" O.C. 3" O.C. 36" O.C. 24" O.C. 18" O.C. 16 12" O.C. 6" O.C. 3" O.C. Factor 36/7 4'-0" 5 SLRFD 829 6'' G' 13.6 36'' 915 SLRFD G' 13.6 SLRFD 993 G' 13.7 SLRFD 1131 G' 13.8 SLRFD 1416 36/9 G' 14.0 SLRFD 1416 6'' G' 14.1 36'' SLRFD 1079 G' 21.1 SLRFD 1198 G' 21.2 SLRFD 1306 G' 21.4 SLRFD 1492 36/11 G' 21.6 SLRFD 1856 6'' G' 22.0 36'' 1856 SLRFD G' 22.3 SLRFD 1306 G' 38.8 SLRFD 1453 G' 39.2 SLRFD 1586 G' 39.7 SLRFD 1812 G' 40.3 SLRFD 2251 G' 41.5 SLRFD 2251 G' 42.4 SLRFD 1337 G' 62.1 SLRFD 1492 G' 63.3 SLRFD 1632 G' 64.1 SLRFD 1866 G' 65.8 SLRFD 2307 G' 68.5 SLRFD 2307 G' 70.9 4 674 9.9 753 9.9 823 10.0 939 10.0 1151 10.1 1151 10.2 881 15.4 989 15.5 1084 15.6 1237 15.8 1500 16.0 1500 16.2 1067 28.8 1201 29.2 1317 29.5 1502 30.0 1815 30.8 1815 31.3 1095 46.9 1235 47.8 1355 48.8 1545 49.8 1853 51.8 1853 53.2 5'-0" 5 4 727 600 16.3 11.9 1-1/2'' 820 687 16.4 12.0 907 765 16.6 12.1 1059 894 16.8 12.2 1376 1130 17.1 12.4 1376 1130 17.3 12.6 1-1/2'' 952 790 24.9 18.4 1083 910 25.3 18.7 1202 1015 25.5 18.9 1407 1186 25.9 19.1 1813 1478 26.6 19.6 1-1/2'' 1813 1478 27.1 19.9 1155 959 44.6 33.7 1316 1106 45.5 34.4 1462 1235 46.3 35.0 1712 1442 47.4 35.8 2200 1790 49.3 37.1 2200 1790 51.0 38.2 1186 987 69.4 53.5 1356 1142 71.4 55.2 1510 1276 73.0 56.5 1770 1487 75.8 58.1 2261 1831 80.0 61.3 2261 1831 84.0 64.1 Span (ft- in.) 6'-0" 7'-0" 8'-0" Fasteners per sheet to support 36/5 5 4 5 4 5 4 655 548 600 508 552 474 6'' 152 mm 18.8 13.8 21.0 15.6 23.0 17.2 36'' 753 640 703 604 664 576 19.0 14.0 21.4 15.9 23.5 17.6 845 722 798 690 761 665 19.2 14.2 21.7 16.1 23.9 17.9 1007 861 967 836 936 816 19.5 14.4 22.1 16.4 24.6 18.3 1346 1115 1324 1104 1307 1095 36/7 20.0 14.7 22.8 16.8 25.4 18.9 1346 1115 1324 1104 1307 1095 6'' 152 mm 20.4 14.9 23.3 17.1 26.1 19.3 36'' 862 725 795 676 743 638 28.3 21.2 31.3 23.6 33.7 25.7 1000 852 938 809 890 775 28.8 21.6 32.1 24.2 34.8 26.6 1126 964 1069 926 1025 896 29.2 21.9 32.7 24.6 35.7 27.2 1345 1148 1299 1119 1262 1096 36/9 29.9 22.3 33.6 25.2 36.9 28.0 1781 1462 1757 1450 1738 1441 6'' 152 mm 30.9 22.9 35.0 26.2 38.8 29.2 36'' 1781 1462 1757 1450 1738 1441 31.7 23.4 36.1 26.8 40.2 30.1 1047 881 967 823 905 778 49.3 37.8 53.2 41.2 56.2 44.0 1217 1038 1143 986 1085 946 50.8 38.9 55.2 42.8 58.8 46.1 1372 1175 1304 1130 1252 1095 36/11 51.8 39.7 56.8 44.1 61.0 47.8 1640 1397 1585 1364 1542 1337 6'' 53.8 41.0 59.2 45.7 64.1 50.0 36'' 2164 1772 2136 1759 2114 1748 56.5 42.9 63.3 48.4 69.0 53.5 2164 1772 2136 1759 2114 1748 58.8 44.4 66.2 50.5 73.0 56.2 1079 910 999 853 937 808 74.6 58.6 78.7 62.4 81.3 65.4 1259 1075 1185 1025 1129 985 77.5 61.0 82.6 65.7 86.2 69.6 1422 1218 1356 1174 1304 1140 80.0 62.9 86.2 68.5 90.1 73.0 1700 1446 1647 1414 1605 1389 84.0 65.7 90.9 72.1 97.1 77.8 2227 1815 2202 1803 2182 1793 90.1 70.2 99.0 78.2 107.5 85.5 2227 1815 2202 1803 2182 1793 96.2 74.1 106.4 82.6 116.3 91.7 9'-0" 914/7 10'-0" 5 4 5 517 448 490 24.8 18.7 26.3 1-1/2'' 914 mm 633 554 607 25.5 19.3 27.3 732 645 709 26.0 19.6 28.0 911 800 891 26.8 20.2 29.0 1293 1087 1216 914/9 28.0 20.9 30.4 1293 1087 1216 28.8 21.4 31.4 1-1/2'' 914 mm 696 608 661 35.8 27.7 37.7 851 748 820 37.3 28.7 39.5 990 872 961 38.5 29.5 41.0 1233 1078 1209 914/11 40.0 30.6 42.9 1723 1433 1584 42.4 32.2 45.9 1-1/2'' 714 mm 1723 1433 1584 44.1 33.2 47.8 856 742 810 58.5 46.4 60.2 1040 914 1002 61.7 49.1 64.5 1210 1067 1175 64.5 51.0 67.6 1507 1316 1479 68.5 54.0 71.9 1-1/2'' 2096 1739 2082 74.6 58.3 79.4 2096 1739 2082 79.4 61.3 85.5 888 772 848 83.3 67.7 84.0 1083 953 1046 89.3 72.9 91.7 1263 1113 1229 94.3 76.9 97.1 1572 1369 1545 102.0 82.8 106.4 2165 1786 2152 114.9 92.1 120.5 2165 1786 2152 125.0 99.0 133.3 4 428 20.1 38 mm 536 20.8 629 21.3 787 21.9 1081 22.8 1081 23.5 38 mm 582 29.4 726 30.8 853 31.7 1063 33.0 1427 35.0 38 mm 1427 36.2 713 48.3 888 51.5 1043 54.1 1299 57.5 1732 62.9 1732 66.7 743 69.5 928 75.6 1090 80.0 1352 87.2 1779 98.2 1779 106.4 1 Tabulated diaphragm shear values are for attachment of steel deck to a base steel thickness, tf ≥ 1/4". 2 Tabulated LRFD diaphragm shear loads are calculated with a phi factor (Φ) of 0.70 for wind loads. To calculate LRFD values for load combinations involving earthquake, divide values in table by 0.70 and multiply by a phi factor (Φ) of 0.65. Panel buckling has been checked. 3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 39 6'' 152 mm 36'' 1-1/2'' 914 mm 38 mm 152 mm 914 mm 38 mm Steel Deck Fastening Systems 1.3 X-ENP-19 for Fastening Deck to Structural Steel 36/7 6'' 152 mm 36'' 914/9 (36/9) 914/9 c 914/7 (36/7) 914/7 1-1/2'' 914 mm 38 mm 152 mm 914 mm 38 mm Limit States Design (LSD)- Factored resistance diaphragm shears, SLSD, (N/mm) and stiffness factors, G', (103 N/mm) for standard 38 mm deep flutes, 152 mm center-to-center steel deck (Fy ≥ 230 MPa; Fu ≥ 310 MPa) installed with Hilti X-ENP-19 L15 fasteners with 914/9 (36/9) or 914/7 (36/7) end and interior support fastener patterns1,2,3,4,5 Gauge Sidelap spacing Hilti SLC6,7,8 36/9 900 mm o.c. 6'' 152 mm 36'' 600 mm o.c. 450 mm o.c. 22 300 mm o.c. 150 mm o.c. 36/11 75 mm o.c. 6'' 36'' 900 mm o.c. 600 mm o.c. 450 mm o.c. 20 300 mm o.c. 150 mm o.c. 75 mm o.c. 900 mm o.c. 600 mm o.c. 450 mm o.c. 18 300 mm o.c. 150 mm o.c. 75 mm o.c. 900 mm o.c. 600 mm o.c. 450 mm o.c. 16 300 mm o.c. 150 mm o.c. 75 mm o.c. Factor 914/11 1200 9 7 SLSD 18.2 12.7 G' 9.7 9.2 1-1/2'' 714 mm SLSD 19.4 14.1 G' 9.8 9.3 SLSD 20.6 15.4 G' 9.8 9.4 SLSD 22.9 17.9 G' 10.0 9.7 SLSD 28.4 23.8 G' 10.3 10.1 SLSD 35.0 30.4 G' 10.5 10.5 1-1/2''16.5 SLSD 23.4 G' 13.7 12.8 SLSD 25.2 18.5 G' 13.8 13.1 SLSD 26.9 20.4 G' 13.9 13.3 SLSD 30.0 23.8 G' 14.2 13.7 SLSD 37.4 31.7 G' 14.7 14.4 SLSD 45.7 39.8 G' 15.4 15.2 SLSD 28.3 20.0 G' 21.7 19.6 SLSD 30.5 22.4 G' 22.2 20.4 SLSD 32.6 24.7 G' 22.2 20.8 SLSD 36.4 28.9 G' 22.7 21.7 SLSD 45.5 38.5 G' 23.8 23.3 SLSD 55.4 48.2 G' 25.6 25.0 SLSD 28.8 20.5 G' 30.3 27.0 SLSD 31.2 23.1 G' 30.3 27.8 SLSD 33.4 25.6 G' 31.3 28.6 SLSD 37.5 30.0 G' 32.3 30.3 SLSD 46.8 39.9 G' 34.5 33.3 SLSD 56.7 49.4 G' 37.0 35.7 1500 9 15.5 10.7 38 16.9 10.9 18.2 11.0 20.7 11.2 26.8 11.7 34.2 12.2 20.1 14.8 22.1 15.0 23.9 15.2 27.4 15.7 35.6 16.5 44.9 17.2 24.4 22.5 26.8 23.0 29.1 23.3 33.3 24.4 43.3 26.1 54.4 27.8 24.9 30.3 27.5 31.3 29.9 32.3 34.4 33.3 44.8 37.0 55.8 40.0 7 11.0 10.0 mm 12.4 10.3 13.8 10.5 16.5 10.8 22.8 11.5 29.9 12.0 14.4 13.6 16.4 14.0 18.4 14.3 22.0 15.0 30.5 16.1 39.3 17.2 17.4 20.2 20.0 21.0 22.4 21.7 26.9 22.9 37.2 25.3 47.7 27.8 17.9 26.3 20.7 27.8 23.3 29.4 28.0 31.3 38.6 34.5 48.9 38.5 Span (mm) 1800 2100 2400 Fasteners per sheet to support 914/9 9 7 9 7 9 7 13.5 9.6 11.9 8.7 10.7 8.0 152 mm 11.4 10.6 11.9 10.9 12.2 11.1 15.1 11.3 13.6 10.4 12.4914 mm 9.7 11.7 10.9 12.3 11.4 12.7 11.8 16.5 12.7 15.2 11.9 14.1 11.3 11.9 11.2 12.5 11.8 13.0 12.2 19.1 15.5 18.0 14.7 17.1 14.1 12.2 11.7 13.0 12.5 13.7 13.0 25.7 22.1 24.8 21.6 24.1 21.2 914/11 12.9 12.6 13.9 13.6 14.7 14.5 33.6 29.6 33.1 29.3 26.8 26.8 152 mm 13.5 13.5 14.7 14.5 15.6 15.6 714 mm 17.7 12.8 15.7 11.6 14.2 10.7 15.4 14.0 15.8 14.2 15.9 14.3 19.9 15.0 18.2 13.9 16.7 13.1 15.8 14.6 16.3 15.0 16.6 15.2 21.8 17.0 20.2 16.0 19.0 15.3 16.1 15.2 16.7 15.6 17.2 15.9 25.5 20.8 24.0 19.9 22.9 19.2 16.7 15.9 17.5 16.6 18.1 17.2 34.2 29.7 33.2 29.1 32.4 28.6 17.9 17.4 19.0 18.5 19.9 19.4 44.2 39.0 43.7 38.9 35.0 35.0 18.9 18.9 20.4 20.0 21.7 21.3 21.6 15.6 19.3 14.2 17.5 13.1 22.7 20.2 22.7 19.9 22.4 19.6 24.1 18.3 22.1 17.0 20.5 16.1 23.5 21.3 23.6 21.2 23.6 21.1 26.5 20.8 24.6 19.6 23.1 18.7 24.4 22.2 24.4 22.2 24.4 22.2 31.0 25.4 29.3 24.4 27.9 23.6 25.3 23.7 25.8 24.2 26.2 24.6 41.7 36.3 40.5 35.5 39.6 35.0 27.6 26.7 28.7 27.8 29.5 28.6 53.7 47.3 53.1 47.0 50.1 46.8 30.3 29.4 31.3 31.3 33.3 32.3 22.1 16.1 20.0 14.8 18.1 13.7 29.9 26.0 29.3 25.3 28.6 24.5 24.8 19.0 22.8 17.7 21.3 16.7 31.1 27.6 30.7 27.2 30.2 26.7 27.4 21.6 25.5 20.4 24.0 19.5 32.3 29.4 32.3 28.6 31.3 28.6 32.1 26.5 30.4 25.5 29.1 24.7 33.9 31.4 34.1 31.6 34.2 31.7 43.2 37.7 42.1 37.0 41.2 36.5 37.7 36.2 38.6 37.2 39.3 37.9 55.2 48.6 54.7 48.3 54.3 48.1 41.7 41.7 43.5 43.5 45.5 43.5 2700 9 9.9 12.5 11.6 13.0 13.3 13.3 16.3 14.1 21.2 15.4 21.2 16.7 13.1 15.9 15.5 16.7 18.0 17.5 22.0 18.5 27.6 20.8 27.6 22.7 16.1 22.1 19.1 23.4 22.0 24.4 26.9 26.4 38.8 30.2 39.6 34.5 16.7 27.8 20.0 29.7 22.9 31.3 28.1 34.1 40.5 39.8 49.5 45.5 3000 7 9 7.4 9.2 11.2 12.7 9.138 mm 10.9 12.0 13.2 10.8 12.6 12.7 13.7 13.7 15.7 13.5 14.5 20.8 17.2 15.2 16.1 21.2 17.2 16.4 17.5 38 mm 10.0 12.2 14.3 15.9 12.4 14.7 15.4 16.9 14.7 17.1 16.1 17.5 18.7 21.3 17.5 18.9 27.6 22.4 20.0 21.3 27.6 22.4 22.2 23.3 12.3 15.0 19.2 21.7 15.3 18.0 20.8 23.3 18.0 21.0 22.2 24.4 22.9 26.0 25.0 26.3 34.6 32.1 29.4 30.3 39.6 32.1 33.3 34.5 12.8 15.6 23.8 27.1 16.0 18.9 26.2 29.1 18.8 21.9 28.6 31.3 24.0 27.2 31.6 34.0 36.1 39.9 38.4 40.2 47.9 40.1 45.5 47.6 7 7.0 11.4 8.7 12.2 10.4 12.8 13.3 13.9 17.2 15.6 17.2 17.2 9.5 14.1 11.9 15.4 14.2 16.4 18.2 17.9 22.4 20.8 22.4 23.3 11.6 18.9 14.6 20.8 17.4 22.2 22.4 25.0 32.1 30.3 32.1 34.5 12.2 23.2 15.4 25.7 18.2 27.8 23.5 31.6 35.8 38.8 40.1 45.5 1 Tabulated diaphragm shear values are for attachment of steel deck to a base steel thickness, tf ≥ 6 mm. 2 Tabulated LSD diaphragm shear loads are calculated with a phi factor (Φ) of 0.65 for wind loads. To calculate LSD values for load combinations involving earthquake, divide values in table by 0.65 and multiply by a phi factor (Φ) of 0.60. Panel buckling has been checked. 3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60. 40 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 6''152 mm 36'' 914 mm1-1/2'' 38 mm 152 mm 914 mm 38 mm Steel Deck Fastening Systems X-ENP-19 for Fastening Deck to Structural Steel 1.3 c 36/4 6''152 mm 36'' 914/5 (36/5) 914/5 914/4 (36/4) 914/4 914 mm1-1/2'' 38 mm 152 mm 914 mm 38 mm Limit States Design (LSD)- Factored resistance diaphragm shears, SLSD, (N/mm) and stiffness factors, G', (103 N/mm) for standard 38 mm deep flutes, 152 mm center-to-center steel deck (Fy ≥ 230 MPa; Fu ≥ 310 MPa) installed with Hilti X-ENP-19 L15 fasteners with 914/5 (36/5) or 914/4 (36/4) end and interior support fastener patterns1,2,3,4,5 Gauge Sidelap spacing Hilti 36/5 SLC6,7,8 900 6''mm 152 o.c. mm 36'' 600 mm o.c. 450 mm o.c. 22 300 mm o.c. 36/7o.c. 150 mm 75 6''mm o.c. 152 mm 36'' 900 mm o.c. 600 mm o.c. 450 mm o.c. 20 36/9o.c. 300 mm 150 6''mm 152 o.c. mm 36'' 75 mm o.c. 900 mm o.c. 600 mm o.c. 450 36/11 mm o.c. 18 300 6''mm o.c. 36'' 150 mm o.c. 75 mm o.c. 900 mm o.c. 600 mm o.c. 450 mm o.c. 16 300 mm o.c. 150 mm o.c. 75 mm o.c. Factor 914/7 1200 5 4 SLSD 11.4 9.2 G' 2.3 1.7 914 mm1-1/2'' SLSD 12.5 10.3 G' 2.4 1.7 SLSD 13.6 11.3 G' 2.4 1.7 SLSD 15.5 12.8 G' 2.4 1.7 SLSD 19.2 15.6 914/9 G' 2.4 1.7 SLSD 19.2 15.6 G' 2.4 1.8 914 mm1-1/2'' SLSD 14.8 12.1 G' 3.6 2.7 SLSD 16.4 13.6 G' 3.7 2.7 SLSD 17.9 14.8 G' 3.7 2.7 SLSD 20.4 16.9 914/11 G' 3.7 2.7 SLSD 25.2 20.3 G' 3.8 2.8 714 mm1-1/2'' SLSD 25.2 20.3 G' 3.8 2.8 SLSD 17.9 14.6 G' 6.7 5.0 SLSD 19.9 16.5 G' 6.8 5.1 SLSD 21.7 18.0 G' 6.8 5.1 SLSD 24.8 20.5 G' 7.0 5.2 1-1/2'' SLSD 30.6 24.6 G' 7.2 5.3 SLSD 30.6 24.6 G' 7.4 5.4 SLSD 18.4 15.0 G' 10.8 8.1 SLSD 20.5 16.9 G' 11.0 8.3 SLSD 22.4 18.6 G' 11.1 8.4 SLSD 25.5 21.1 G' 11.4 8.6 SLSD 31.3 25.2 G' 11.9 8.9 SLSD 31.3 25.2 G' 12.3 9.3 1500 5 4 10.0 8.2 2.8 2.1 38 mm 11.3 9.4 2.8 2.1 12.4 10.5 2.9 2.1 14.5 12.2 2.9 2.1 18.7 15.3 2.9 2.1 18.7 15.3 3.0 2.2 38 mm 13.1 10.8 4.3 3.2 14.9 12.5 4.4 3.2 16.5 13.9 4.4 3.3 19.3 16.2 4.5 3.3 24.6 20.0 4.6 3.4 38 mm 24.6 20.0 4.7 3.4 15.9 13.2 7.8 5.8 18.1 15.2 7.9 6.0 20.0 16.9 8.0 6.1 23.4 19.7 8.2 6.2 29.9 24.3 8.5 6.4 29.9 24.3 8.8 6.6 16.3 13.6 12.0 9.3 18.6 15.7 12.5 9.6 20.7 17.5 12.7 9.8 24.2 20.3 13.2 10.1 30.7 24.9 13.9 10.6 30.7 24.9 14.5 11.1 Span (mm) 1800 2100 2400 Fasteners per sheet to support 914/5 5 4 5 4 5 4 9.0 7.5 8.3 7.0 7.6 6.5 3.2 2.4 3.6152 mm 2.7 4.0 3.0 914 mm 10.3 8.8 9.7 8.3 9.1 7.9 3.3 2.4 3.7 2.8 4.1 3.1 11.6 9.9 11.0 9.5 10.5 9.1 3.3 2.5 3.8 2.8 4.1 3.1 13.8 11.8 13.3 11.4 12.8 11.2 3.4 2.5 3.8 2.8 4.3 3.2 18.3 15.1 18.0 15.0 17.7 14.8 914/7 3.5 2.5 3.9 2.9 4.4 3.3 18.3 15.1 18.0 15.0 17.7 14.8 3.5 2.6 4.0152 mm 3.0 4.5 3.3 914 mm 11.8 10.0 10.9 9.3 10.2 8.8 4.9 3.7 5.4 4.1 5.8 4.5 13.7 11.7 12.9 11.1 12.2 10.6 5.0 3.7 5.6 4.2 6.1 4.6 15.4 13.2 14.7 12.7 14.1 12.3 5.1 3.8 5.6 4.3 6.2 4.7 18.4 15.7 17.8 15.3 17.3 15.0 914/9 5.2 3.9 5.8 4.4 6.4 4.8 24.2 19.8 23.8 19.7 23.6 19.5 5.3 4.0 6.1152 mm 4.5 6.7 5.1 914 mm 24.2 19.8 23.8 19.7 23.6 19.5 5.5 4.0 6.3 4.6 6.9 5.2 14.4 12.1 13.3 11.3 12.4 10.7 8.5 6.6 9.3 7.2 9.8 7.7 16.7 14.2 15.7 13.5 14.9 13.0 8.8 6.7 9.6 7.4 10.2 8.0 18.8 16.1 17.9 15.5 17.2 15.0 914/11 9.0 6.9 9.9 7.6 10.6 8.3 22.5 19.1 21.7 18.7 21.1 18.3 152 mm 9.3 7.1 10.3 7.9 11.1 8.7 714 mm 29.4 24.0 29.0 23.9 28.7 23.7 9.8 7.4 11.0 8.4 12.0 9.3 29.4 24.0 29.0 23.9 28.7 23.7 10.2 7.7 11.5 8.7 12.7 9.7 14.8 12.5 13.7 11.7 12.9 11.1 13.0 10.2 13.7 10.9 14.3 11.4 17.3 14.8 16.3 14.1 15.5 13.5 13.5 10.6 14.5 11.5 15.2 12.1 19.5 16.7 18.6 16.1 17.9 15.6 13.9 11.0 14.9 11.9 15.9 12.7 23.3 19.8 22.6 19.4 22.0 19.0 14.5 11.4 15.9 12.5 16.9 13.5 30.2 24.6 29.9 24.5 29.6 24.3 15.6 12.2 17.2 13.6 18.5 14.8 30.2 24.6 29.9 24.5 29.6 24.3 16.7 12.8 18.5 14.3 20.0 15.9 2700 5 7.1 4.3 8.7 4.4 10.1 4.5 12.5 4.7 17.5 4.9 17.5 5.0 9.6 6.3 11.7 6.5 13.6 6.7 16.9 6.9 23.4 7.4 23.4 7.6 11.8 10.2 14.3 10.8 16.6 11.2 20.7 11.9 28.4 13.0 28.4 13.7 12.2 14.5 14.9 15.6 17.3 16.4 21.6 17.9 29.4 20.0 29.4 21.7 3000 4 5 6.2 6.7 3.2 4.6 38 mm 7.6 8.3 3.3 4.7 8.9 9.7 3.4 4.9 11.0 12.2 3.5 5.0 14.7 17.2 3.6 5.3 14.7 17.2 3.7 5.4 38 mm 8.4 9.1 4.8 6.6 10.3 11.3 5.0 6.9 12.0 13.2 5.1 7.1 14.8 16.6 5.3 7.5 19.4 22.4 5.6 7.9 38 mm 19.4 22.4 5.7 8.3 10.2 11.2 8.1 10.5 12.5 13.8 8.5 11.2 14.6 16.1 8.9 11.8 18.0 20.3 9.4 12.5 38 mm 23.6 28.2 10.1 13.9 23.6 28.2 10.6 14.7 10.6 11.7 11.8 14.7 13.1 14.4 12.7 16.1 15.3 16.9 13.3 16.9 18.7 21.2 14.4 18.5 24.2 29.2 16.0 21.3 24.2 29.2 17.2 23.3 4 5.9 3.5 7.4 3.6 8.6 3.7 10.8 3.8 14.7 4.0 14.7 4.0 8.0 5.1 10.0 5.3 11.7 5.5 14.6 5.7 19.4 6.1 19.4 6.3 9.8 8.5 12.2 9.0 14.3 9.4 17.8 10.0 23.5 10.9 23.5 11.5 10.2 12.2 12.7 13.2 15.0 14.1 18.5 15.2 24.1 17.1 24.1 18.5 1 Tabulated diaphragm shear values are for attachment of steel deck to a base steel thickness, tf ≥ 6 mm. 2 Tabulated LSD diaphragm shear loads are calculated with a phi factor (Φ) of 0.65 for wind loads. To calculate LSD values for load combinations involving earthquake, divide values in table by 0.65 and multiply by a phi factor (Φ) of 0.60. Panel buckling has been checked. 3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 41 Steel Deck Fastening Systems 1.3 X-ENP-19 for Fastening Deck to Structural Steel c Limit States Design-Factored resistance diaphragm tables for deck fasteners (Canada) Diaphragm Table 36-7 w/X-ENP-19 L15 Metric Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor, F, (mm x 10-6/N) for 38 mm deep steel nestable deck fastened with Hilti X-ENP-19 L15 with screwed sidelaps (Canada only)1, 2, 3 No. of transverse nails per 900 mm wide deck units=7 (every flute) Sidelap Connection #12 screw at 600 mm O.C. #12 screw at 450 mm O.C. #12 screw at 300 mm O.C. #12 screw at 150 mm O.C. Span (mm) 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16 Deck gauge thickness Strength, SLSD 7.1 8.5 11.2 13.9 7.1 8.5 11.2 13.9 9.2 11.0 14.6 18.2 12.8 15.4 20.3 25.4 1200 Flexibility Factor, F 109 78 51 38 109 78 51 38 104 74 47 34 99 69 43 30 Strength, SLSD 5.6 8.5 8.9 11.3 6.7 8.0 10.6 13.2 8.5 10.2 13.4 16.8 12.2 14.7 19.4 24.3 1500 Flexibility Factor, F 102 75 52 39 98 72 49 37 93 68 45 33 87 62 40 29 Strength, SLSD 5.5 6.7 8.8 11.0 6.3 7.8 10.2 12.7 7.9 9.5 12.6 15.7 11.8 14.2 18.8 23.5 1800 Flexibility Factor, F 94 71 50 38 91 68 47 36 86 64 44 33 79 57 38 28 Strength, SLSD 4.7 5.6 7.5 9.4 5.4 6.6 8.7 10.9 7.5 9.2 12.0 15.0 11.5 13.9 18.3 22.9 2100 Flexibility Factor, F 93 72 52 41 89 68 49 38 82 61 43 33 74 54 37 27 Strength, SLSD 4.7 5.8 7.6 9.5 5.4 6.5 8.6 10.8 7.3 8.7 11.5 14.5 11.3 13.6 18.0 22.6 2400 Flexibility Factor, F 89 69 50 40 85 66 48 38 78 60 42 33 70 52 35 27 Strength, SLSD 4.2 5.1 6.7 8.5 5.3 6.5 8.6 10.8 7.1 8.5 11.2 14.0 11.0 13.4 17.6 22.2 2700 Flexibility Factor, F 89 70 52 42 82 64 47 37 76 58 42 33 66 50 35 26 Strength, SLSD 4.2 5.2 6.8 8.6 4.8 5.8 7.6 9.6 6.8 8.2 10.9 13.6 10.9 13.3 17.4 21.9 3000 Flexibility Factor, F 86 68 51 42 82 65 49 39 73 57 41 33 64 48 34 26 Diaphragm Table 36-4 w/X-ENP-19 L15 Metric Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor, F, (mm x 10-6/N) for 38 mm deep steel nestable deck fastened with Hilti X-ENP-19 L15 with screwed sidelaps (Canada only)1, 2, 3 No. of transverse nails per 900 mm wide deck units=4 (every flute) Sidelap Connection #12 screw at 600 mm O.C. #12 screw at 450 mm O.C. #12 screw at 300 mm O.C. #12 screw at 150 mm O.C. Span (mm) 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16 Deck gauge thickness Strength, SLSD 5.1 6.1 8.0 10.0 5.1 6.1 8.0 10.0 6.7 8.1 10.7 13.4 8.8 10.7 14.0 17.5 1200 Flexibility Factor, F 582 372 200 123 582 372 200 123 573 364 193 117 565 357 187 111 Strength, SLSD 4.2 5.1 6.7 8.3 5.1 6.1 8.0 10.0 6.3 7.8 10.2 12.7 8.7 10.5 13.7 17.2 1500 Flexibility Factor, F 483 313 173 110 477 307 168 105 469 300 162 100 460 292 155 94 Strength, SLSD 4.3 5.2 6.8 8.6 4.9 6.0 7.9 9.9 6.1 7.4 9.8 12.2 8.6 10.3 13.5 16.9 1800 Flexibility Factor, F 413 270 151 98 407 265 147 94 400 258 141 89 390 249 134 82 Strength, SLSD 3.6 4.5 6.0 7.5 4.3 5.3 6.9 8.7 6.0 7.3 9.5 11.9 8.5 10.2 13.4 16.8 2100 Flexibility Factor, F 368 244 141 93 362 238 136 89 351 228 127 81 340 219 119 74 Strength, SLSD 3.9 4.7 6.2 7.8 4.5 5.4 7.1 8.8 5.9 7.1 9.3 11.6 8.3 10.1 13.3 16.7 2400 Flexibility Factor, F 329 220 128 86 324 215 124 82 314 206 116 75 303 196 107 67 Strength, SLSD 3.4 4.1 5.5 6.9 4.5 5.4 7.2 8.9 5.8 6.9 9.2 11.4 8.3 10.1 13.2 16.6 2700 Flexibility Factor, F 305 206 123 84 294 196 115 77 285 188 107 70 274 178 99 62 Strength, SLSD 3.6 4.3 5.8 7.3 4.1 4.9 6.5 8.1 5.6 6.8 8.9 11.3 8.2 10.0 13.2 16.5 3000 Flexibility Factor, F 280 190 115 79 275 186 111 76 262 174 101 67 251 164 92 59 Diaphragm Table 36-7 w/X-ENP-19 L15 Metric Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor, F, (mm x 10-6/N) for 38 mm deep steel deck fastened with Hilti X-ENP-19 L15 w/button punch sidelaps (Canada only)1, 2, 3 No. of transverse nails per 900 mm wide deck units=7 (every flute) Sidelap Connection Button Punch 600 mm O.C. Button Punch 450 mm O.C. Button Punch 300 mm O.C. Button Punch 150 mm O.C. Span (mm) 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16 Deck gauge thickness Strength, SLSD 6.1 7.5 10.1 12.9 6.1 7.5 10.1 12.9 6.9 8.6 11.9 15.6 8.2 10.5 15.0 20.4 1200 Flexibility Factor, F 113 82 54 40 113 82 54 40 112 81 53 40 110 79 52 38 Strength, SLSD 4.8 6.0 8.1 10.3 5.2 6.5 8.9 11.6 5.8 7.3 10.3 13.9 7.2 9.3 13.6 18.9 1500 Flexibility Factor, F 106 79 55 42 106 79 55 42 105 78 54 41 102 76 52 40 Strength, SLSD 4.2 5.3 7.3 9.6 4.6 5.6 8.0 10.7 5.1 6.5 9.3 12.7 6.6 8.6 12.8 17.9 1800 Flexibility Factor, F 103 79 57 45 103 79 56 44 101 77 55 43 98 75 53 41 Strength, SLSD 3.6 4.5 6.2 8.2 3.9 4.8 6.8 9.2 4.5 5.8 8.5 11.8 6.0 8.0 12.1 17.2 2100 Flexibility Factor, F 103 81 60 48 102 80 59 47 100 78 57 46 96 74 54 43 Strength, SLSD 3.3 4.2 5.9 7.9 3.5 4.5 6.3 8.7 4.1 5.3 7.9 11.0 5.6 7.5 11.5 16.6 2400 Flexibility Factor, F 104 83 62 51 103 82 62 50 101 80 60 49 95 75 56 45 Strength, SLSD 2.9 3.6 5.2 7.1 3.3 4.2 6.1 8.3 3.8 4.9 7.4 10.5 5.3 7.2 11.2 16.1 2700 Flexibility Factor, F 106 86 66 54 104 84 64 53 102 82 63 51 96 76 58 47 Strength, SLSD 2.8 3.5 5.1 6.9 2.9 3.8 5.4 7.5 3.5 4.7 7.1 10.0 5.1 6.9 10.8 15.6 3000 Flexibility Factor, F 108 89 69 57 107 88 68 57 104 84 65 54 96 78 59 49 1 The ratio of span of deck unit to average length of sheet is taken to be 1/3. 2 Diaphragm loads are based on steel decks having an average ultimate tensile strength of 55 ksi. 3 Values shown calculated in accordance with SDI equations using a φ factor of 0.5 for LSD for all load conditions. Note: Reference pages 40-41 for generally higher diaphragm capacities with Hilti Sidelap Connectors (SLC). 42 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 Steel Deck Fastening Systems X-ENP-19 for Fastening Deck to Structural Steel 1.3 c Limit States Design-Factored resistance diaphragm tables for deck fasteners (Canada) Diaphragm Table 36-4 w/X-ENP-19 L15 Metric Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor, F, (mm x 10-6/N) for 38 mm deep steel deck fastened with Hilti X-ENP-19 L15 w/button punch sidelaps (Canada only)1,2,3 No. of transverse nails per 900 mm wide deck units=4 (every other flute) Sidelap Connection Button Punch 600 mm O.C. Button Punch 450 mm O.C. Button Punch 300 mm O.C. Button Punch 150 mm O.C. Span (mm) 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16 Deck gauge thickness Strength, SLSD 4.3 5.4 7.2 9.3 4.3 5.4 7.2 9.3 4.9 6.2 8.7 11.5 6.0 7.6 11.0 14.8 1200 Flexibility Factor, F 589 378 205 128 589 378 205 128 587 377 204 127 584 374 201 124 Strength, SLSD 3.5 4.3 5.9 7.6 3.8 4.8 6.6 8.6 4.3 5.5 7.8 10.5 5.5 7.1 10.3 14.2 1500 Flexibility Factor, F 492 322 180 116 491 321 179 115 489 318 177 114 484 314 174 111 Strength, SLSD 3.2 3.9 5.5 7.4 3.4 4.2 6.1 8.2 3.9 5.1 7.2 9.9 5.2 6.7 10.0 13.7 1800 Flexibility Factor, F 430 285 165 110 428 284 164 109 426 282 162 107 419 276 157 102 Strength, SLSD 2.6 3.3 4.7 6.2 2.8 3.6 5.3 7.2 3.4 4.6 6.8 9.4 4.8 6.3 9.6 13.4 2100 Flexibility Factor, F 388 262 156 107 387 261 155 106 382 257 152 103 374 250 145 97 Strength, SLSD 2.5 3.2 4.6 6.2 2.6 3.4 5.1 7.1 3.2 4.2 6.5 8.9 4.6 6.1 9.3 13.2 2400 Flexibility Factor, F 358 246 150 106 356 244 149 105 351 240 145 101 341 231 138 94 Strength, SLSD 2.2 2.8 4.0 5.5 2.5 3.3 4.8 6.9 3.1 4.0 6.1 8.7 4.5 6.0 9.2 12.9 2700 Flexibility Factor, F 337 235 148 107 333 232 145 104 328 227 141 101 316 216 132 92 Strength, SLSD 2.1 2.7 4.0 5.5 2.2 2.9 4.3 6.1 2.8 3.9 5.9 8.5 4.3 5.8 8.9 12.7 3000 Flexibility Factor, F 320 227 146 107 318 225 145 106 311 218 139 101 297 206 128 91 Diaphragm Table 24-5 w/X-ENP-19 L15 Metric Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor, F, (mm x 10-6/N) for 75 mm deep steel nestable deck fastened with Hilti X-ENP-19 L15 with screwed sidelaps (Canada only)1,2,3 No. of transverse nails per 600 mm wide deck units=5 (every flute) Sidelap Connection #12 screw at 600 mm O.C. #12 screw at 450 mm O.C. #12 screw at 300 mm O.C. #12 screw at 150 mm O.C. Span (mm) 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16 Deck gauge thickness Strength, SLSD 4.1 4.9 6.6 8.2 4.7 5.8 7.6 9.5 6.7 8.1 10.7 13.4 10.8 13.2 17.3 21.7 2400 Flexibility Factor, F 190 144 102 79 183 138 96 74 169 125 85 65 154 112 73 54 Strength, SLSD 3.6 4.5 5.8 7.3 4.8 5.9 7.6 9.6 6.6 7.9 10.5 13.2 10.7 12.9 17.0 21.5 2700 Flexibility Factor, F 188 145 105 83 174 132 93 73 161 121 84 64 145 106 71 53 Strength, SLSD 3.8 4.6 6.1 7.6 4.3 5.3 6.9 8.7 6.3 7.8 10.2 12.8 10.6 12.8 16.9 21.3 3000 Flexibility Factor, F 179 139 101 80 172 133 96 75 155 117 82 63 138 102 69 52 Strength, SLSD 3.4 4.2 5.5 6.9 4.5 5.3 7.1 8.8 6.2 7.6 10.0 12.6 10.5 12.7 16.8 21.0 3300 Flexibility Factor, F 179 141 104 84 165 129 93 74 150 114 81 63 132 99 67 51 Strength, SLSD 3.6 4.3 5.8 7.2 4.5 5.4 7.2 8.9 6.2 7.5 9.9 12.5 10.5 12.6 16.7 20.9 3600 Flexibility Factor, F 172 136 101 81 160 125 91 73 146 112 80 63 128 96 66 50 Strength, SLSD 3.3 4.0 5.3 6.7 4.1 5.1 6.6 8.3 6.1 7.4 9.8 12.2 10.3 12.6 16.6 20.8 3900 Flexibility Factor, F 173 138 104 84 160 127 94 75 142 110 79 62 124 93 65 49 Strength, SLSD 3.4 4.2 5.5 6.9 4.2 5.2 6.7 8.5 6.0 7.3 9.6 12.1 10.3 12.5 16.5 20.7 4200 Flexibility Factor, F 168 134 101 82 156 124 92 74 139 108 79 62 120 91 64 49 Diaphragm Table 24-5 w/X-ENP-19 L15 Metric Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor, F, (mm x 10-6/N) for 75 mm deep steel deck fastened with Hilti X-ENP-19 L15 w/button punch sidelaps (Canada only)1,2,3 No. of transverse nails per 600 mm wide deck units=5 (every flute) Sidelap Connection Button Punch 600 mm O.C. Button Punch 450 mm O.C. Button Punch 300 mm O.C. Button Punch 150 mm O.C. Span (mm) 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16 Deck gauge thickness Strength, SLSD 2.7 3.4 4.8 6.6 2.9 3.8 5.4 7.3 3.5 4.6 6.8 9.6 5.1 6.8 10.7 15.5 2400 Flexibility Factor, F 226 177 130 104 224 175 128 103 218 170 124 99 206 158 114 90 Strength, SLSD 2.5 3.1 4.3 5.9 2.8 3.5 5.2 7.2 3.3 4.2 6.5 9.3 4.8 6.6 10.5 15.2 2700 Flexibility Factor, F 228 182 136 111 224 177 133 108 217 172 128 103 203 158 116 93 Strength, SLSD 2.4 2.9 4.2 5.9 2.5 3.2 4.7 6.5 3.1 4.1 6.2 9.0 4.6 6.3 10.1 14.9 3000 Flexibility Factor, F 230 185 141 116 227 183 139 114 218 175 132 108 201 159 118 96 Strength, SLSD 2.1 2.7 3.9 5.3 2.4 3.1 4.6 6.5 2.9 3.9 6.0 8.8 4.5 6.2 10.0 14.7 3300 Flexibility Factor, F 235 192 148 123 230 187 144 119 220 178 137 112 201 160 121 99 Strength, SLSD 2.1 2.7 3.9 5.4 2.4 3.1 4.6 6.5 2.8 3.8 5.9 8.6 4.3 6.0 9.8 14.5 3600 Flexibility Factor, F 239 196 153 128 233 191 149 124 223 182 141 117 201 162 123 101 Strength, SLSD 1.9 2.5 3.6 5.1 2.1 2.8 4.2 6.0 2.7 3.6 5.8 8.3 4.2 5.9 9.6 14.2 3900 Flexibility Factor, F 246 204 161 135 239 198 156 131 226 186 146 121 201 164 126 104 Strength, SLSD 1.9 2.5 3.6 5.1 2.1 2.8 4.2 6.0 2.6 3.5 5.6 8.2 4.1 5.8 9.5 14.1 4200 Flexibility Factor, F 250 209 166 140 243 203 161 135 230 191 150 126 202 166 128 106 1 The ratio of span of deck unit to average length of sheet is taken to be 1/3. 2 Diaphragm loads are based on steel decks having an average ultimate tensile strength of 55 ksi. 3 Values shown calculated in accordance with SDI equations using a φ factor of 0.5 for LSD for all load conditions. Note: Reference pages 40-41 for generally higher diaphragm capacities with Hilti Sidelap Connectors (SLC). Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 43 Steel Deck Fastening Systems 1.3 X-ENP-19 for Fastening Deck to Structural Steel 1.3.4 Ordering Information DX 860-ENP-L Decking System Tools Description DX 860-ENP-L Stand-Up Decking Tool Accessories Description Notes Qty Use-on-Demand service provides daily rental 1 pcs Notes Qty Replacement piston and brake for DX 860-ENP-L 1 pcs Fasteners (Combos with 40-strip Cartridges) Description Notes Qty X-ENP-19 MXR bulk fastener/cartridge combo X-ENP-19 MXR pallet fastener/cartridge combo tf ≥ 1/4" (6 mm) tf ≥ 1/4" (6 mm) 2,000 pcs 32,000 pcs Notes Qty Includes 10 fastener magazine 1 pcs X 860-ENP Piston and Brake Spares Pack DX 76 Decking System Tools Description DX 76 Hand Held Decking Tool with MX76 Magazine Accessories Description Notes Qty 1 pcs X-76-PS Piston Stopper Replacement magazine for DX 76-MX Single fastener baseplate for DX 76 Replacement piston and stopper for DX 76 Replacement stopper for DX 76 Fasteners (Combos with 10-strip cartridges) Description Base Steel Thickness Qty X-ENP-19 MX bulk fastener/cartridge combo X-ENP-19 MX pallet fastener/cartridge combo tf ≥ 1/4" (6 mm) tf ≥ 1/4" (6 mm) 1,000 pcs 32,000 pcs Fasteners (Non-Combo) Description Base Steel Thickness Qty X-ENP-19 L15 Fastener (singles) tf ≥ 1/4" (6 mm) 100 pcs MX 76 Magazine X-76-FN-15 X-76-P-ENP Piston with stopper 1 pcs 1 pcs 1 pcs 44 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 Steel Deck Fastening Systems Racing Tip Screw Deck Fastening System 1.4 1.4.1 Product Description The Hilti Racing Tip fastening system consists of the Hilti SDT 5 stand-up screw fastening system and the S-MD 12-24 x 1-5/8 M HWH5 Racing Tip fasteners, which are available in a collated version. Torque Screwdriver. Loaded with up to 50 frame fasteners or sidelap connectors this system can perform frame attachment and sidelap connections. Contact Hilti for specific tool recommendations. The SDT 5 Decking system can be powered with either the ST 1800 Adjustable Torque Screwdriver or the ST 1800-A18 Cordless Adjustable Hilti S-MD 12-24 x 1-5/8 M HWH5 Racing Tip steel deck fasteners comply with ANSI/SDI RD1.0, C1.0 and NC1.0 standards. 1.4.1 Product Description 1.4.2 Material Specifications 1.4.3 Technical Data 1.4.4 Ordering Information 1.4.2 Material Specifications Fastener designation S-MD 12-24 x 1-5/8 M HWH5 Fastener material Carbon Steel Fastener plating 5 µm Zinc1 1 ASTM B633, SC 1, Type III. Reference Section 2.3.3.1 of Hilti North American Product Technical Guide Volume 1: Direct Fastening for more information. S-MD 12-24 x 1-5/8 M HWH5 Approvals/Listings 1.4.3 Technical Data Allowable pullout loads for attachments to steel base material lb (kN)1,3,4 Base material thickness in. (Gauge) 1/42 1/82 0.0598 (16) 0.0747 (14) 0.1046 (12) S-MD 12-24 x 1-5/8 M HWH5 215 (0.96) 265 (1.18) 370 (1.65) 505 (2.25) 505 (2.25) Fastener 1 Unless otherwise noted, allowable load values based upon calculations done in accordance with Section E4 of AISI S100 with Fu = 58 ksi. 2 Allowable load values based upon testing performed in ASTM A36 (Fu ≥ 58 ksi) plate steel. 3 Allowable tension pullout load values must be compared with allowable tension pullover load values. Use lesser value. 4 Allowable load values based on safety factor of 3.0 per AISI S100. FM (Factory Mutual) For attaching Class 1 Steel Roof Decks with 1-60, 1-75 and 1-90 wind uplift ratings UL (Underwriters Laboratories) Fasteners for attaching steel roof deck (uplift and fire classification) Allowable tension pullover and shear bearing loads for attaching steel deck 1,2,3,4 Steel deck gauge (in.) Fastener S-MD 12-24 x 1-5/8 M HWH5 1 2 3 4 5 16 (0.0598) Tension lb (kN) 18 (0.0474) Shear lb (kN) 5 Tension lb (kN) 20 (0.0358) Shear lb (kN) 5 Tension lb (kN) Shear lb (kN) 22 (0.0295) Tension lb (kN) Shear lb (kN) 24 (0.0239) Tension lb (kN) Shear lb (kN) 560 620 445 620 335 555 275 400 225 260 (2.49) (2.76) (1.98) (2.76) (1.49) (2.47) (1.22) (1.78) (1.00) (1.16) Allowable load values are based upon a safety factor of 3.0 per AISI S100. Allowable load values based upon ASTM A1008, or minimum ASTM A653 SQ33 steel deck. Allowable tension pullover load values based upon calculations done in accordance with Section E4 of AISI S100 with Fu = 45 ksi. Allowable tension pullover load values must be compared with allowable tension pullout load values. Use lesser value. Allowable load value limited by screw fastener shear strength. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 45 6'' 36'' 6'' 1-1/2'' 36'' 152 mm 914 mm 1-1/2'' 38 mm Steel Deck Fastening Systems 1.4 Racing Tip Screw Deck Fastening System 36/7 6'' 914/7 36/5 36'' 6'' 1-1/2'' 36'' 152 mm 914 mm 1-1/2'' 38 mm Allowable Stress Design (ASD) - Allowable diaphragm shears, SASD, (plf) and stiffness factors, G', (kips/in.) for standard 1-1/2" deep flutes, 6" center-to-center steel deck (Fy ≥ 33 ksi; Fu ≥ 45 ksi) installed with Hilti S-MD 12-24 x 1-5/8 M HWH5 fasteners with 36/7 or 36/5 end and interior support fastener patterns1,2,3,4,5 Gauge Sidelap spacing Hilti SLC6,7,8 36" O.C. 24" O.C. 22 18" O.C. 12" O.C. 6" O.C. 36" O.C. 24" O.C. 20 18" O.C. 12" O.C. 6" O.C. 36" O.C. 24" O.C. 18 18" O.C. 12" O.C. 6" O.C. Span (ft- in.) 4'-0" Factor 36/9 S6'' ASD G' 36'' 5'-0" 6'-0" 7'-0" 8'-0" 9'-0" 7 5 7 5 7 5 7 5 344 308 299 272 265 247 240 6'' 228 48.2 13.2 51.6 15.8 53.7 18.0 54.9 20.0 1-1/2'' 7 10'-0" 914/9 36/7 Fasteners per sheet to support 7 5 7 5 221152 mm 212 208 199 197 189 55.5 55.8 23.4 55.9 24.8 36'' 5 21.8 1-1/2'' 914 mm SASD 385 343 342 310 312 286 291 269 272 255 259 244 248 235 G' 49.9 13.4 54.2 16.0 57.1 18.5 59.2 20.7 60.7 22.7 61.7 24.5 62.5 26.2 SASD 424 374 384 344 355 322 334 306 318 294 306 284 296 275 G' 51.2 13.5 56.2 16.3 59.9 18.8 62.7 21.1 64.8 23.3 66.4 25.3 67.7 27.2 SASD 496 372 402 390 353 G'36/11 53.3 SASD 6'' G' SASD 36'' 427 460 403 435 385 416 13.7 59.4 16.5 64.1 19.2 67.8 362 21.836/970.9 24.1 914/11 73.4 26.4 381 346 75.5 28.5 663 531 639 519 622 510 609 503 600 498 592 493 585 490 56.9 13.9 64.7 17.0 71.1 19.9 76.4 6'' 22.7 mm 81.0152 25.3 85.0 27.8 88.4 30.3 463 416 400 365 353 329 318 302 291 278 271 259 256 246 34.9 1-1/2'' 36'' 714 mm 1-1/2'' G' 65.5 20.3 68.2 23.8 69.4 26.8 69.7 29.3 69.5 31.5 69.1 33.3 68.6 SASD 514 459 454 412 411 378 379 352 353 333 333 317 318 304 G' 68.3 20.6 72.3 24.4 74.7 27.7 76.1 30.6 76.9 33.2 77.4 35.5 77.6 37.5 SASD 563 499 505 455 464 424 435 400 412 382 394 367 379 355 G' 70.7 20.9 75.7 24.8 79.0 28.4 81.3 31.5 83.0 34.4 84.2 37.0 85.0 39.4 SASD 654 568 601 531 564 505 537 48536/11516 469 499 457 486 446 G' 74.3 21.2 80.9 25.5 85.7 29.3 89.4 32.8 36.1 94.5 39.1 96.4 41.9 655 762 648 112.4 1-1/2'' 42.0 SASD 872 711 835 691 809 676 789 664 6'' G' 80.8 21.8 90.0 26.4 97.3 30.7 103.3 34.7 92.2 774 36'' 108.2 38.5 752 642 115.9 45.4 SASD 540 484 470 428 422 389 383 359 354 336 331 318 313 301 G' 97.6 36.5 97.6 41.5 96.3 45.4 94.5 48.4 92.7 50.8 90.8 52.6 89.1 54.2 SASD 606 539 540 488 493 452 459 424 434 403 413 386 395 372 G' 103.1 37.5 105.0 43.1 105.4 47.7 105.0 51.5 104.3 54.7 103.5 57.4 102.6 59.7 SASD 669 588 606 543 562 509 530 484 505 465 485 449 469 437 G' 107.7 38.2 111.2 44.3 113.0 49.5 113.8 53.9 114.1 57.7 114.2 61.0 114.0 63.9 SASD 784 673 728 636 689 609 660 588 637 573 620 560 605 549 G' 115.2 39.3 121.2 46.1 125.1 52.0 127.8 57.3 129.7 61.9 131.1 66.0 132.1 69.7 SASD 1046 835 1010 816 984 803 965 793 950 785 938 778 928 773 G' 129.2 41.0 139.6 48.8 147.4 55.9 153.4 62.3 158.2 68.2 162.2 73.6 165.4 78.6 38 mm 38 mm 1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses, tf , with the range 16 gauge (0.0598") ≤ tf ≤ 1/4". 2 Tabulated ASD diaphragm shear loads are calculated with a safety factor (Ω) of 2.35 for wind loads. To calculate ASD values for load combinations involving earthquake, multiply values in table by 2.35 and divide by a safety factor (Ω) of 2.50. Panel buckling has been checked. 3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60. 46 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 6'' 36'' 152 mm 1-1/2'' EDN IMPERIAL 914 mm 38 mm Steel Deck Fastening Systems Racing Tip Screw Deck Fastening System 1.4 36/3 36/4 6'' 36'' 914/4 6'' 152 mm 36'' 1-1/2'' 914 mm 1-1/2'' 38 mm Allowable Stress Design (ASD) - Allowable diaphragm shears, SASD, (plf) and stiffness factors, G', (kips/in.) for standard 1-1/2" deep flutes, 6" center-to-center steel deck (Fy ≥ 33 ksi; Fu ≥ 45 ksi) installed with Hilti S-MD 12-24 x 1-5/8 M HWH5 fasteners with 36/4 or 36/3 end and interior support fastener patterns1,2,3,4,5 Gauge Sidelap spacing Hilti SLC6,7,8 36" O.C. 24" O.C. 22 18" O.C. 12" O.C. 6" O.C. 36" O.C. 24" O.C. 20 18" O.C. 12" O.C. 6" O.C. 36" O.C. 24" O.C. 18 18" O.C. 12" O.C. 6" O.C. Span (ft- in.) 4'-0" Factor 36/5 5'-0" 6'-0" 7'-0" 8'-0" 4 3 4 3 4 3 4 3 252 212 226 194 207 181 194 171 9.7 4.9 11.6 6.0 13.4 7.1 15.1 8.1 SASD 283 233 260 220 244 209 232 G' 9.8 5.0 11.8 6.1 13.7 7.2 15.5 SASD 310 251 291 240 276 231 265 G' 9.8 5.0 12.0 6.1 13.9 7.3 15.8 SASD 354 276 339 269 329 263 320 259 9.9 5.0 12.1 6.2 14.2 7.4 16.2 8.5 6'' S ASD G' 36'' G'36/7 SASD 6'' G' SASD 36'' 9'-0" 36/4 Fasteners per sheet to support 1-1/2'' 10'-0" 914/5 4 3 6'' 183152 mm 163 36'' 4 3 4 3 174 157 167 152 10.0 19.2 10.8 9.0 201 222 194 214 189 208 185 8.2 17.2 9.3 18.7 10.2 20.2 11.2 225 257 220 250 215 244 212 8.4 17.6 9.4 19.3 10.4 20.8 11.4 314 256 309 253 36/5 9.6 18.1 17.9 1-1/2'' 914 mm 16.6 914/710.6 19.9 305 251 21.7 11.7 429 311 423 309 418 307 415 306 412 305 410 304 408 303 10.1 5.1 12.4 6.3 14.6 7.5 16.8 8.6 6'' 152 mm 18.8 9.8 20.8 10.9 22.8 12.0 339 286 301 260 275 241 255 227 239 215 224 206 214 198 16.3 1-1/2'' 36'' 914 mm 1-1/2'' G' 15.0 7.8 17.8 9.5 20.3 11.0 22.4 12.5 24.4 13.8 26.1 15.1 27.6 SASD 378 314 345 293 321 277 303 265 289 255 278 247 268 241 G' 15.2 7.9 18.2 9.6 20.9 11.3 23.4 12.8 25.6 14.3 27.7 15.7 29.5 17.1 SASD 413 338 384 320 362 307 346 297 333 289 323 282 315 277 G' 15.4 7.9 18.5 9.7 21.4 11.4 24.0 13.1 26.5 14.6 16.1 30.8 17.6 372 449 361 432 352 419 345 40936/7 339 28.7 395 331 G' 15.6 8.0 18.9 9.9 22.0 11.6 24.9 13.3 27.6 15.0 30.1 16.6 32.5 18.2 578 425 568 421 8.1 19.5 36/9 472 SASD S 6'' ASD G' 36'' 16.0 1-1/2'' 10.0 560 418 554 415 22.8 11.9 26.0 13.7 6'' 549152 mm 414 36'' 15.5 29.1 914/9335 401 546 412 543 1-1/2'' mm 32.0 914 17.2 34.8 396 332 356 306 327 286 306 270 289 258 276 248 265 240 G' 27.5 14.9 31.8 17.7 35.3 20.3 38.2 22.6 40.7 24.7 42.7 26.6 44.4 28.3 SASD 446 367 411 346 385 329 366 317 351 307 340 299 330 292 G' 28.2 15.1 33.0 18.2 37.1 21.0 40.6 23.6 43.7 26.0 46.4 28.3 48.8 30.3 SASD 489 394 458 377 436 364 420 355 407 347 396 340 388 335 G'36/11 28.7 15.3 33.9 18.5 38.4 21.5 42.4 24.3 36/9 26.9 45.9 914/11 49.1 29.4 51.9 31.7 SASD 557 433 535 422 519 414 506 408 497 403 489 399 482 396 G' 6'' 29.5 15.6 35.0 19.0 40.1 22.2 44.7 25.2 48.9 28.1 6'' 152 mm 30.8 56.2 33.4 657 481 652 479 648 36''477 52.7 42.6 23.0 48.0 26.3 53.1 57.8 32.6 62.2 35.6 G' 30.5 487 664 1-1/2'' 483 15.9 36.8 19.5 29.5 mm1-1/2'' 645 714 476 643 38 mm 411 18.9 38 mm SASD SASD 36'' 673 38 mm 475 38 mm 1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses, tf , with the range 16 gauge (0.0598") ≤ tf ≤ 1/4". 2 Tabulated ASD diaphragm shear loads are calculated with a safety factor (Ω) of 2.35 for wind loads. To calculate ASD values for load combinations involving earthquake, multiply values in table by 2.35 and divide by a safety factor (Ω) of 2.50. Panel buckling has been checked. 3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60. 36/11 6'' 36'' 1-1/2'' Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 47 6'' 36'' 6'' 1-1/2'' 36'' 152 mm 914 mm 1-1/2'' 38 mm Steel Deck Fastening Systems 1.4 Racing Tip Screw Deck Fastening System 36/7 6'' 914/7 36/5 36'' 6'' 1-1/2'' 36'' 152 mm 914 mm 1-1/2'' 38 mm Load Resistance Factor Design (LRFD) - Factored resistance diaphragm shears, SLRFD, (plf) and stiffness factors, G', (kips/in.) for standard 1-1/2" deep flutes, 6" center-to-center steel deck (Fy ≥ 33 ksi; Fu ≥ 45 ksi) installed with Hilti S-MD 12-24 x 1-5/8 M HWH5 fasteners with 36/7 or 36/5 end and interior support fastener patterns1,2,3,4,5 Gauge Sidelap spacing Hilti SLC6,7,8 36" O.C. 24" O.C. 22 18" O.C. 12" O.C. 6" O.C. 36" O.C. 24" O.C. 20 18" O.C. 12" O.C. 6" O.C. 36" O.C. 24" O.C. 18 18" O.C. 12" O.C. 6" O.C. Span (ft- in.) 4'-0" Factor 36/9 S6'' LRFD G' 36'' 5'-0" 6'-0" 7'-0" 8'-0" 9'-0" 7 5 7 5 7 5 7 5 565 507 491 448 436 405 394 6'' 374 48.2 13.2 51.6 15.8 53.7 18.0 54.9 20.0 1-1/2'' 7 10'-0" 914/9 Fasteners per sheet to36/7 support 7 5 7 5 363152 mm 348 341 327 324 311 55.5 55.8 23.4 55.9 24.8 36'' 5 21.8 914 mm 1-1/2'' SLRFD 633 563 562 509 513 470 477 441 447 419 425 401 407 386 G' 49.9 13.4 54.2 16.0 57.1 18.5 59.2 20.7 60.7 22.7 61.7 24.5 62.5 26.2 SLRFD 697 614 631 565 584 530 550 503 523 483 503 466 486 453 G' 51.2 13.5 56.2 16.3 59.9 18.8 62.7 21.1 64.8 23.3 66.4 25.3 67.7 27.2 SLRFD 816 611 660 641 581 702 756 662 714 633 684 13.7 59.4 16.5 64.1 19.2 67.8 1089 873 1050 852 1022 838 56.9 13.9 64.7 17.0 71.1 19.9 761 684 657 600 579 G'36/11 53.3 SLRFD 6'' G' SLRFD 36'' 1-1/2'' 594 914/11 73.4 26.4 626 569 75.5 28.5 21.8 36/970.9 24.1 1001 826 985 817 972 810 962 805 76.4 22.7 6'' mm 81.0152 25.3 27.8 88.4 30.3 540 522 495 36'' 479 85.0 457 445 714 mm 1-1/2'' 426 421 404 G' 65.5 20.3 68.2 23.8 69.4 26.8 69.7 29.3 69.5 31.5 69.1 33.3 68.6 SLRFD 845 755 745 677 676 621 623 579 580 547 547 521 522 500 G' 68.3 20.6 72.3 24.4 74.7 27.7 76.1 30.6 76.9 33.2 77.4 35.5 77.6 37.5 925 820 830 748 763 696 714 657 677 627 647 603 623 584 G' 70.7 20.9 75.7 24.8 79.0 28.4 81.3 31.5 83.0 34.4 84.2 37.0 85.0 39.4 SLRFD 1075 933 988 873 927 830 882 79736/11 848 771 820 750 798 734 G' 74.3 21.2 80.9 25.5 85.7 29.3 89.4 32.8 92.2 36.1 94.5 39.1 96.4 41.9 SLRFD 1434 1168 1372 1135 1329 1110 1297 1092 6'' 1272 1077 80.8 21.8 90.0 26.4 97.3 30.7 103.3 34.7 1252 1065 1236 112.4 1-1/2'' 42.0 115.9 1056 G' SLRFD 887 796 772 704 693 639 630 590 581 552 544 522 514 495 G' 97.6 36.5 97.6 41.5 96.3 45.4 94.5 48.4 92.7 50.8 90.8 52.6 89.1 54.2 38.5 38 mm 34.9 SLRFD 36'' 108.2 38 mm 45.4 SLRFD 996 886 887 802 811 742 755 697 712 662 678 635 648 612 G' 103.1 37.5 105.0 43.1 105.4 47.7 105.0 51.5 104.3 54.7 103.5 57.4 102.6 59.7 SLRFD 1099 967 996 891 923 837 870 796 829 764 797 739 771 718 G' 107.7 38.2 111.2 44.3 113.0 49.5 113.8 53.9 114.1 57.7 114.2 61.0 114.0 63.9 SLRFD 1288 1105 1196 1044 1132 1000 1084 967 1047 941 1018 920 995 903 G' 115.2 39.3 121.2 46.1 125.1 52.0 127.8 57.3 129.7 61.9 131.1 66.0 132.1 69.7 SLRFD 1719 1372 1659 1341 1617 1319 1585 1302 1561 1289 1541 1279 1526 1270 G' 129.2 41.0 139.6 48.8 147.4 55.9 153.4 62.3 158.2 68.2 162.2 73.6 165.4 78.6 1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses, tf , with the range 16 gauge (0.0598") ≤ tf ≤ 1/4". 2 Tabulated LRFD diaphragm shear loads are calculated with a phi factor (Φ) of 0.70 for wind loads. To calculate LRFD values for load combinations involving earthquake, divide values in table by 0.70 and multiply by a phi factor (Φ) of 0.65. Panel buckling has been checked. 3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60. 48 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 6'' 36'' 152 mm 1-1/2'' EDN IMPERIAL 914 mm 38 mm Steel Deck Fastening Systems Racing Tip Screw Deck Fastening System 1.4 36/3 36/4 6'' 36'' 914/4 6'' 152 mm 36'' 1-1/2'' 914 mm 1-1/2'' 38 mm Load Resistance Factor Design (LRFD) - Factored resistance diaphragm shears, SLRFD, (plf) and stiffness factors, G', (kips/in.) for standard 1-1/2" deep flutes, 6" center-to-center steel deck (Fy ≥ 33 ksi; Fu ≥ 45 ksi) installed with Hilti S-MD 12-24 x 1-5/8 M HWH5 fasteners with 36/4 or 36/3 end and interior support fastener patterns1,2,3,4,5 Gauge Sidelap spacing Hilti SLC6,7,8 36" O.C. 24" O.C. 22 18" O.C. 12" O.C. 6" O.C. 36" O.C. 24" O.C. 20 18" O.C. 12" O.C. 6" O.C. 36" O.C. 24" O.C. 18 18" O.C. 12" O.C. 6" O.C. Span (ft- in.) 4'-0" Factor 36/5 5'-0" 6'-0" 7'-0" 8'-0" 4 3 4 3 4 3 4 3 414 348 371 319 341 298 318 282 9.7 4.9 11.6 6.0 13.4 7.1 15.1 8.1 SLRFD 465 384 428 361 401 344 381 G' 9.8 5.0 11.8 6.1 13.7 7.2 15.5 SLRFD 510 412 477 394 454 380 436 G' 9.8 5.0 12.0 6.1 13.9 7.3 15.8 SLRFD 582 453 558 442 540 433 527 426 9.9 5.0 12.1 6.2 14.2 7.4 16.2 8.5 S6'' LRFD G' 36'' G'36/7 SLRFD 6'' G' SLRFD 36'' 9'-0" 36/4 Fasteners per sheet to support 1-1/2'' 10'-0" 914/5 4 3 6'' 300152 mm 268 36'' 4 3 4 3 286 258 274 249 10.0 19.2 10.8 9.0 330 365 319 352 311 342 304 8.2 17.2 9.3 18.7 10.2 20.2 11.2 369 422 361 411 354 402 348 8.4 17.6 9.4 19.3 10.4 20.8 11.4 516 420 508 416 36/5 9.6 18.1 17.9 1-1/2'' 914 mm 16.6 914/710.6 19.9 501 412 21.7 11.7 705 511 695 507 687 504 682 502 677 501 674 499 671 498 10.1 5.1 12.4 6.3 14.6 7.5 16.8 8.6 6'' 152 mm 18.8 9.8 20.8 10.9 22.8 12.0 556 470 495 428 452 396 419 372 393 353 369 338 352 325 16.3 1-1/2'' 36'' 914 mm 1-1/2'' G' 15.0 7.8 17.8 9.5 20.3 11.0 22.4 12.5 24.4 13.8 26.1 15.1 27.6 SLRFD 621 516 567 482 527 456 498 435 475 419 456 406 441 395 G' 15.2 7.9 18.2 9.6 20.9 11.3 23.4 12.8 25.6 14.3 27.7 15.7 29.5 17.1 SLRFD 679 555 631 526 595 505 569 488 548 474 531 464 518 455 G' 15.4 7.9 18.5 9.7 21.4 11.4 24.0 13.1 26.5 14.6 16.1 30.8 17.6 612 737 593 710 578 689 567 67236/7 558 28.7 648 544 G' 15.6 8.0 18.9 9.9 22.0 11.6 24.9 13.3 27.6 15.0 30.1 16.6 32.5 18.2 950 698 933 692 8.1 19.5 36/9 775 SLRFD S6'' LRFD G' 36'' 16.0 1-1/2'' 10.0 920 687 910 683 22.8 11.9 26.0 13.7 6'' 903152 mm 680 36'' 15.5 29.1 914/9550 659 897 677 892 1-1/2'' mm 32.0 914 17.2 34.8 651 546 585 502 538 470 502 444 475 424 453 408 435 394 G' 27.5 14.9 31.8 17.7 35.3 20.3 38.2 22.6 40.7 24.7 42.7 26.6 44.4 28.3 SLRFD 732 603 675 568 633 541 602 521 577 505 558 491 542 480 G' 28.2 15.1 33.0 18.2 37.1 21.0 40.6 23.6 43.7 26.0 46.4 28.3 48.8 30.3 SLRFD 803 647 753 620 717 599 690 583 668 570 651 559 637 550 G'36/11 28.7 15.3 33.9 18.5 38.4 21.5 42.4 24.3 36/9 26.9 45.9 914/11 49.1 29.4 51.9 31.7 SLRFD 916 711 879 694 852 681 832 670 816 662 803 655 793 650 G' 6'' 29.5 15.6 35.0 19.0 40.1 22.2 44.7 25.2 48.9 28.1 6'' 152 mm 52.7 30.8 56.2 33.4 32.6 62.2 35.6 G' 30.5 799 10911-1/2'' 794 1080 790 1072 787 1065 36''785 mm1-1/2'' 1060 714 783 1056 15.9 36.8 42.6 23.0 48.0 26.3 53.1 57.8 19.5 29.5 38 mm 675 18.9 38 mm SLRFD SLRFD 36'' 1106 38 mm 781 38 mm 1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses, tf , with the range 16 gauge (0.0598") ≤ tf ≤ 1/4". 2 Tabulated LRFD diaphragm shear loads are calculated with a phi factor (Φ) of 0.70 for wind loads. To calculate LRFD values for load combinations involving earthquake, divide values in table by 0.70 and multiply by a phi factor (Φ) of 0.65. Panel buckling has been checked. 3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60. 36/11 6'' 36'' 1-1/2'' Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 49 6'' 152 mm 36'' 1-1/2'' 914 mm 914 mm 38 mm 38 mm Steel Deck Fastening Systems 1.4 Racing Tip Screw Deck Fastening System 36/5 914/7 (36/7) 914/7 6'' 152 mm 36'' c 914/5 (36/5) 914/5 1-1/2'' 914 mm 152 mm 38 mm 914 mm 38 mm Limit States Design (LSD) - Factored resistance diaphragm shears, SLSD, (N/mm) and stiffness factors, G', (103 N/mm) for standard 38 mm deep flutes, 152 mm center-to-center steel deck (Fy ≥ 230 MPa; Fu ≥ 310 MPa) installed with Hilti S-MD 12-24 x 1-5/8 M HWH5 fasteners with 914/7 (36/7) or 914/5 (36/5) end and interior support fastener patterns1,2,3,4,5 Gauge Sidelap spacing 36/7 Hilti SLC6,7,8 6'' 152 mm 900 mm O.C. 36'' 600 mm O.C. 22 450 mm O.C. 300 mm 36/9O.C. 150 mm O.C. 6'' 152 mm 36'' 900 mm O.C. 600 mm O.C. 20 450 mm O.C. 36/11 300 mm O.C. 6'' 150 mm O.C. 36'' 900 mm O.C. 600 mm O.C. 18 450 mm O.C. 300 mm O.C. 150 mm O.C. Span (mm) 1200 Factor 914/9 SLSD G' SLSD 1500 1800 2100 2400 2700 914/7 Fasteners per sheet to support 3000 7 5 7 5 7 5 5 7 5 7 5 7.0 6.8 6.1 6.0 5.6 7 5 152 mm 5.4 5.1 7 7.8 5.0 4.8 4.7 4.5 4.5 4.3 8.4 2.3 9.0 2.7 9.4 3.1 9.6 3.5 9.7 3.8 9.8 4.1 9.8 4.3 8.7 7.7 7.7 7.0 7.1 6.5 6.6 6.1 6.2 5.8 5.8 5.5 5.6 5.3 1-1/2'' 914 mm 38 mm 914 mm 38 mm G' 8.7 2.3 9.5 2.8 10.0 3.2 10.4 3.6 10.6 3.9 10.8 4.3 11.0 4.6 SLSD 9.6 8.4 8.7 7.8 8.0 7.3 7.6 6.9 7.2 6.6 6.9 6.4 6.7 6.2 G' 8.9 2.3 9.8 2.8 10.5 3.3 11.0 3.7 11.3 4.0 11.6 4.4 11.9 4.7 SLSD 11.2 9.6 10.4 9.1 9.8 8.7 9.4 8.4 9.1 8.1 8.0 8.6 7.8 2.4 10.3 2.9 11.2 3.3 11.8 3.8 914/9 4.2 12.4 8.8 12.8 4.6 13.2 4.9 SLSD 14.9 11.9 14.4 11.6 14.0 11.4 13.7 11.3 13.5 11.2 13.3 11.1 13.2 11.0 9.9 2.4 11.2 2.9 12.4 3.4 152 mm 13.3 3.9 14.1 10.5 9.4 9.0 8.2 8.0 7.4 7.2 6.8 6.6 914/11 9.3 G' G' SLSD 1-1/2'' 714 mm 38 mm 4.4 14.8 4.8 6.3 6.1 5.9 914 mm 15.4 5.2 5.8 5.6 38 mm G' 11.4 3.5 11.9 4.1 12.2 4.6 12.2 5.1 12.2 5.5 12.2 5.8 12.1 6.1 SLSD 11.6 10.4 10.2 9.3 9.3 8.5 8.6 8.0 8.0 7.5 7.5 7.2 7.2 6.9 G' 11.9 3.6 12.7 4.2 13.1 4.8 13.4 5.3 13.5 5.8 13.6 6.2 13.7 6.5 SLSD 12.7 11.2 11.4 10.3 10.5 9.6 9.8 9.0 9.3 8.6 8.9 8.3 8.6 8.0 14.6 6.0 G' 12.3 3.6 13.2 4.3 13.8 4.9 14.3 5.5 SLSD 14.7 12.8 13.6 12.0 12.7 11.4 12.1 10.9 914/1110.6 11.6 14.8 6.4 14.9 6.8 11.3 10.3 11.0 10.1 G' 13.0 3.7 14.1 4.4 15.0 5.1 15.6 5.7 16.2 6.3 16.6 6.8 16.9 7.3 SLSD 19.6 15.9 18.8 15.5 18.2 15.2 152 mm 17.8 14.9 17.4 14.7 17.2 14.6 16.9 14.4 G' 14.1 3.8 15.7 4.6 17.0 5.3 18.0 6.0 18.9 6.7 19.7 7.3 20.3 7.9 SLSD 12.2 10.9 10.6 9.7 9.5 8.8 8.7 8.1 8.0 7.6 7.5 7.2 7.1 6.8 1-1/2'' 714 mm 38 mm G' 17.1 6.3 17.1 7.2 16.9 7.9 16.7 8.4 16.3 8.9 16.0 9.2 15.7 9.5 SLSD 13.7 12.1 12.2 11.0 11.1 10.2 10.4 9.6 9.8 9.1 9.3 8.7 8.9 8.4 10.4 G' 18.1 6.5 18.4 7.5 18.5 8.3 18.5 9.0 18.4 9.5 18.2 10.0 18.1 SLSD 15.1 13.2 13.7 12.2 12.7 11.5 12.0 10.9 11.4 10.5 11.0 10.1 10.6 9.9 G' 18.9 6.6 19.5 7.7 19.8 8.6 20.0 9.4 20.1 10.1 20.1 10.6 20.1 11.1 SLSD 17.7 15.1 16.4 14.3 15.5 13.7 14.9 13.2 14.4 12.9 14.0 12.6 13.7 12.4 G' 20.1 6.8 21.2 8.0 21.9 9.0 22.4 10.0 22.8 10.8 23.0 11.5 23.2 12.2 SLSD 23.5 18.7 22.7 18.3 22.1 18.0 21.7 17.8 21.4 17.6 21.1 17.5 20.9 17.3 G' 22.5 7.1 24.4 8.5 25.8 9.7 26.9 10.8 27.7 11.8 28.4 12.8 29.0 13.7 1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses, tf , with the range 16 gauge (1.5 mm) ≤ tf ≤ 6 mm. 2 Tabulated LSD diaphragm shear loads are calculated with a phi factor (Φ) of 0.65 for wind loads. To calculate LSD values for load combinations involving earthquake, divide values in table by 0.65 and multiply by a phi factor (Φ) of 0.60. Panel buckling has been checked. 3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60. 50 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 152 mm 914 mm 38 mm EDN METRIC EDN IMPERIAL Steel Deck Fastening Systems Racing Tip Screw Deck Fastening System 1.4 c 36/3 914/4 (36/4) 914/4 6'' 152 mm 36'' 914/3 (36/3) 914/3 1-1/2'' 914 mm 152 mm 38 mm 914 mm 38 mm Limit States Design (LSD) - Factored resistance diaphragm shears, SLSD, (N/mm) and stiffness factors, G', (103 N/mm) for standard 38 mm deep flutes, 152 mm center-to-center steel deck (Fy ≥ 230 MPa; Fu ≥ 310 MPa) installed with Hilti S-MD 12-24 x 1-5/8 M HWH5 fasteners with 914/4 (36/4) or 914/3 (36/3) end and interior support fastener patterns1,2,3,4,5 Gauge Sidelap spacing 36/4 Hilti SLC6,7,8 6'' 152 mm 900 mm 36''O.C. 600 mm O.C. 22 450 mm O.C. 30036/5 mm O.C. 150 mm O.C. 6'' 152 mm 36'' 900 mm O.C. 600 mm O.C. 20 450 mm O.C. 36/7 300 mm O.C. 6'' 152 mm 150 mm O.C. 36'' 900 mm O.C. 600 mm O.C. 18 450 mm O.C. 36/9 300 mm O.C. 6'' 152 mm 36'' 150 mm O.C. Span (mm) 1200 Factor 914/5 SLSD G' SLSD 1500 1800 2100 2400 2700 914/4 Fasteners per sheet to support 3000 4 3 4 3 4 3 3 4 3 4 3 4.8 5.1 4.4 4.7 4.1 4 3 152 mm 4.4 3.9 4 5.7 4.1 3.7 3.9 3.5 3.8 3.4 1.7 0.9 2.0 1.0 2.3 1.2 2.6 1.4 2.9 1.6 3.1 1.7 3.3 1.9 6.4 5.2 5.9 4.9 5.5 4.7 5.2 4.5 5.0 4.4 4.8 4.3 4.7 4.2 1-1/2'' 914 mm 38 mm 914 mm 38 mm G' 1.7 0.9 2.0 1.1 2.4 1.2 2.7 1.4 3.0 1.6 3.2 1.8 3.5 1.9 SLSD 7.0 5.6 6.5 5.4 6.2 5.2 6.0 5.1 5.8 4.9 5.6 4.8 5.5 4.8 G' 1.7 0.9 2.1 1.1 2.4 1.3 2.7 1.4 3.0 1.6 3.3 1.8 3.6 2.0 SLSD 7.9 6.2 7.6 6.0 7.4 5.9 7.2 5.8 7.1 5.7 5.7 6.9 5.6 0.9 2.1 1.1 2.5 1.3 2.8 1.5 914/5 1.7 3.1 6.9 3.5 1.8 3.8 2.0 SLSD 9.6 6.9 9.5 6.9 9.4 6.9 9.3 6.8 9.2 6.8 9.2 6.8 9.1 6.8 G'914/7 1.7 G' SLSD 1.7 0.9 2.1 1.1 2.5 1.3 152 mm 2.9 1.5 3.3 7.6 6.4 6.8 5.9 6.2 5.4 5.8 5.4 1-1/2'' 914 mm 38 mm 5.1 1.7 3.6 1.9 3.9 2.1 4.8 5.1 4.6 4.8 4.5 914 mm 38 mm G' 2.6 1.3 3.1 1.6 3.5 1.9 3.9 2.2 4.2 2.4 4.5 2.6 4.8 2.8 SLSD 8.5 7.1 7.8 6.6 7.2 6.2 6.8 6.0 6.5 5.7 6.3 5.6 6.1 5.4 G' 2.6 1.4 3.1 1.7 3.6 1.9 4.1 2.2 4.4 2.5 4.8 2.7 5.1 3.0 SLSD 9.3 7.6 8.6 7.2 8.2 6.9 7.8 6.7 7.5 6.5 7.3 6.3 7.1 6.2 G' 2.7 1.4 3.2 1.7 3.7 2.0 4.2 2.3 4.6 2.5 914/9 10.6 SLSD 8.3 10.1 8.1 9.7 7.9 9.4 7.7 914/7 7.6 9.2 5.0 2.8 5.4 3.0 9.0 7.5 8.9 7.4 G' 2.7 1.4 3.3 1.7 3.8 2.0 4.3 2.3 4.8 2.6 5.2 2.9 5.6 3.1 SLSD 12.9 9.5 12.7 9.4 12.5 9.3 152 mm 12.4 9.3 12.3 9.2 12.2 9.2 12.2 9.2 3.9 2.1 4.5 2.4 5.0 2.7 5.5 3.0 6.0 3.3 7.4 6.4 6.9 6.1 6.5 5.8 6.2 5.6 6.0 5.4 G' SLSD 1-1/2'' 914 2.8 mm 1.4 8.9 7.5 3.438 mm 1.7 8.0 6.9 914 mm 38 mm G' 4.8 2.6 5.5 3.1 6.1 3.5 6.7 3.9 7.1 4.3 7.5 4.6 7.8 4.9 SLSD 10.0 8.2 9.3 7.8 8.7 7.4 8.3 7.1 7.9 6.9 7.7 6.7 7.4 6.6 G' 4.9 2.6 5.7 3.2 6.4 3.6 7.1 4.1 7.6 4.5 8.1 4.9 8.5 5.3 SLSD 11.0 8.8 10.3 8.5 9.8 8.2 9.5 8.0 9.2 7.8 8.9 7.6 8.7 7.5 SLSD 12.5 914/11 5.0 G' 2.7 5.9 3.2 6.7 3.7 7.4 4.2 914/9 4.7 8.0 8.5 5.1 9.0 5.5 9.7 12.0 9.5 11.7 9.3 11.4 9.1 11.2 9.0 11.0 8.9 10.8 8.9 6.1 3.3 14.938 mm 10.8 7.0 3.8 7.8 4.4 152 mm 8.5 4.9 10.7 14.6 10.7 mm 14.591410.7 9.2 14.7 14.4 5.3 9.8 10.638 mm 14.4 10.6 6.4 7.4 4.0 8.3 4.5 9.2 10.0 5.6 6.2 G' 5.1 2.7 1-1/2'' mm SLSD 71415.1 10.9 G' 5.3 2.8 3.4 5.1 10.8 5.8 1 Tabulated diaphragm shear values are for attachment of steel deck to base steel thicknesses, tf , with the range 16 gauge (1.5 mm) ≤ tf ≤ 6 mm. 2 Tabulated LSD diaphragm shear loads are calculated with a phi factor (Φ) of 0.65 for wind loads. To calculate LSD values for load combinations involving earthquake, divide values in table by 0.65 and multiply by a phi factor (Φ) of 0.60. Panel buckling has been checked. 3 Please refer to footnotes 4 through 8 at the end of Section 1.6 on page 60. 914/11 36/11 6'' 36'' 1-1/2'' 152 mm 714 mm 38 mm Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 51 Steel Deck Fastening Systems 1.4 Racing Tip Screw Deck Fastening System 1.4.4 Ordering Information Racing Tip Screw Fastening System SDT 5 Stand Up Decking System* Description Package contents ST 1800 Metal Construction Screwdriver Includes tool with depth gauge, 13 ft supply cord and operating instructions in a cardboard box SDT 5 Stand Up Decking Tool Includes stand up tool, 2 grips, magazine, 5/16" nutsetter, supply cord strain relief clasp and operating instructions * Additional tool and fastener packages available. Contact Hilti for more information. Accessories Description Notes Qty SDT 5 Magazine For use with the SDT 5 Stand Up Decking Tool 1 SDT Integrated Driver and Setter - 5/16" For use with the SDT 5 or SDT 30 Stand Up Decking Tools 1 For attachment of metal deck to bar joist Description Max. drill capacity Qty S-MD 12-24 x 1 5/8" M HWH5 0.500" 250 52 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 Steel Deck Fastening Systems SLC Sidelap Connectors for Fastening Deck-to-Deck 1.5 1.5.1 Product Description The Hilti sidelap fastening system consists of a stand up tool (SDT 5), an electric screwdriver (ST 1800) and collated sidelap connectors. For nestable steel deck profiles, the tool of choice is the SDT 5. It uses the ST 1800 electric or ST 1800-A18 battery screwdriver to drive sidelap connectors through sidelaps ranging from 16 to 26 gauge in thickness. Featuring an adjustable torque clutch, the ST 1800 or ST 1800-A18 helps ensure proper fastening while minimizing overdrive. 1.5.1 Product Description screw driver provides for a completely stand-up and cordless deck attachment. 1.5.2 Material Specifications 1.5.3 Technical Data When compared with fastening individual, non-collated, screws, the SDT 5 offers the installer the capability to work upright. By improving the comfort and health of the installer, productivity remains high all day, helping keep the project on time and on budget. 1.5.4 Ordering Information S-SLC 01 M HWH Collated Sidelap Connectors Hilti steel deck sidelap fasteners comply with ANSI/SDI RD1.0, C1.0 and NC1.0 standards. When used with the SDT 5 and Hilti's DX 860 tools, the ST 1800-A18 cordless S-SLC 01 M HWH Sidelap Connector 1.5.2 Material Specifications Fastener material Carbon Steel Carbon Steel Carbon Steel Fastener S-SLC 01 M HWH S-SLC 02 M HWH Hilti #10 HWH Screw S-SLC 02 M HWH Collated Sidelap Connectors Fastener plating 5 µm Zinc1 5 µm Zinc2 5 µm Zinc2 1 EN/ISO 4042 A/3/E. Reference Hilti North American Product Technical Guide Volume 1: Direct Fastening Section 2.3.3.1 for more information. 2 Minimum requirements of ASTM F1941. Reference Hilti North American Product Technical Guide Volume 1: Direct Fastening Section 2.3.3.1 for more information. 1.5.3 Technical Data Allowable tension (pullout or pullover) and shear bearing loads for Hilti SLC Sidelap Connectors1,2,3 Sheet Steel Gauge Fastener S-SLC 01 M HWH4,5 S-SLC 02 M HWH5 Hilti #10 HWH Screw6 22 to 22 20 to 20 18 to 18 16 to 16 Tension Shear Tension Shear Tension Shear Tension Shear lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 105 240 120 290 150 385 (0.47) (1.07) (0.53) (1.29) (0.67) (1.71) – – 85 240 100 290 130 385 165 485 (0.38) (1.07) (0.44) (1.29) (0.58) (1.71) (0.73) (2.16) 70 210 85 255 115 340 145 430 (0.31) (0.93) (0.38) (1.13) (0.51) (1.51) (0.64) (1.91) 1 Based upon attachment of two-same thickness layers of ASTM A1008 or minimum ASTM A653 SQ33 steel deck. 2 Allowable capacities based on a safety factor of 3.0. 3 Allowable tension capacities based upon the controlling capacity of pullout, pullover or fastener tension strength. 4 Use of S-SLC 01 M HWH with 18 gauge steel deck is recommended only for standard tensile strength (45 ≤ Fu ≤ 65 ksi) steel deck. For high tensile strength (Fu > 65 ksi) 18 gauge steel deck, use S-SLC 02 M HWH. 5 Allowable shear capacities calculated according to Section 4.5 of SDI DDM03 for standard No. 12 screw. For shear capacities when used in diaphragm applications in combination with Hilti deck frame fasteners, reference Qs values in Table 8 in Section 1.1.8. 6 Allowable shear capacities calculated according to Section 4.5 of SDI DDM03 for standard No. 10 screw. S-SLC 02 M HWH Sidelap Connectors Approvals/Listings ICC-ES (International Code Council) ESR-2776 (AC43 for S-SLC 01 and S-SLC 02) ESR-2197 (AC43 for #10 HWH Screws) ESR-2196 (AC118 for S-SLC 02 and #10 HWH Screws) COLA (City of Los Angeles) RR 25877, RR 25678, RR 25296 FM (Factory Mutual) S-SLC 01 M HWH and S-SLC 02 M HWH fasteners for securing Class 1 Steel Roof Deck sidelaps with 1-60 and 1-90 wind uplift ratings. S-SLC 02 M HWH listed for higher wind uplift ratings with FM Approved Lightweight Insulating Concrete Roof Deck Assemblies. Refer to FM RoofNav for specific assembly listings. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 53 Steel Deck Fastening Systems 1.5 SLC Sidelap Connectors for Fastening Deck-to-Deck 1.5.4 Ordering Information SDT Stand-Up Decking Tool System Tools Description Notes Qty SDT 5 Stand Up Tool (for use with the ST 1800 or ST 1800-A18) Includes tool with depth gauge, 13 ft 1 pcs supply Cord and operating instructions Includes tool, (2) B 18 Li-Ion 3.3-Ah CPC batteries, (1) C 4/36-ACS LI TPS charger and operating 1 pcs instructions in a Hilti soft tool bag Includes stand up tool, 2 grips, magazine, bit holder, 1 pcs nut setter, supply cord strain relief Accessories Description Notes Qty SDT 5 Magazine SDT Integrated Driver and Setter Replacement magazine for SDT 5 Single piece design for SDT 5 1 pcs 1 pcs ST 1800 Adjustable Torque Screwdriver ST 1800-A18 Adjustable Torque Cordless Screwdriver Sidelap Connectors (Combos including ST 1800 or ST 1800-A18 and SDT 30) Description Notes SDT 5, ST 1800 and 10,000 Sidelap Connectors SDT 5, ST 1800 and 25,000 Sidelap Connectors SDT 5, ST 1800 and 50,000 Sidelap Connectors SDT 5, ST 1800 and 100,000 Sidelap Connectors ST 1800-A18, SDT 5 and 15,000 Sidelap Connectors Can include collated connector choices below Can include collated connector choices below Can include collated fastener connector choices below Qty 10,000 pcs 25,000 pcs 50,000 pcs Can include collated connector choices below 100,000 pcs Can include collated connector choices below 15,000 pcs Sidelap Connectors (Collated)* Description Deck Thickness (GA) Qty S-SLC 01 M HWH S-SLC 02 M HWH #10 HWH Screw 181, 20, 22, 24, 26 16, 18, 20, 22 18, 20, 22, 24,26 250 250 250 1 Use of S-SLC 01 M HWH with 18 gauge steel deck is recommended only for standard tensile strength (45 ≤ Fu ≤ 65 ksi) steel deck. For high tensile strength (Fu > 65 ksi) 18 gauge steel deck, use S-SLC 02 M HWH. 54 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 Steel Deck Fastening Systems Optimized Diaphragm Shear Tables 1.6 Allowable diaphragm design strength, plf* SASD SASD (wind) (seismic) 272 289 291 309 311 331 333 354 356 379 381 406 408 434 437 464 467 497 500 532 535 569 572 609 612 651 655 697 701 746 750 798 802 854 859 914 919 977 983 1046 1052 1119 1126 1197 1204 1281 1289 1371 1379 1467 1475 1570 1689 1797 1934 2057 2214 2355 2535 2697 Span = 4'-0'' Recommended Hilti powder-actuated frame fastener pattern-sidelap spacing Hilti SLC (in. o.c.)* X-ENP-19 with tf ≥ 1/4" X-HSN 24 with 3/16" ≤ tf ≤ 3/8" X-HSN 24 with 1/8" ≤ tf < 3/16" 22 ga. 20 ga. 18 ga. 16 ga. 22 ga. 20 ga. 18 ga. 22 ga. 20 ga. 18 ga. 36/3-48 36/3-48 36/3-42 36/3-30 36/3-24 36/3-18 36/3-14 36/4-20 36/4-18 36/4-14 36/4-12 36/5-16 36/5-14 36/5-10 36/5-8 36/5-7 36/9-24 36/9-18 36/9-12 36/9-10 36/9-8 36/9-7 36/9-5 36/11-7 36/11-5 36/11-4 36/11-3 36/3-48 36/3-48 36/3-48 36/3-48 36/3-48 36/3-48 36/3-42 36/3-30 36/3-20 36/3-18 36/4-24 36/4-20 36/4-18 36/4-14 36/4-12 36/5-16 36/5-14 36/5-10 36/5-8 36/5-7 36/5-6 36/9-16 36/9-12 36/9-10 36/9-8 36/9-7 36/11-7 36/11-4 36/11-3 36/3-48 36/3-48 36/3-48 36/3-48 36/3-48 36/3-48 36/3-48 36/3-48 36/3-48 36/3-36 36/3-24 36/3-20 36/3-16 36/4-24 36/4-20 36/4-18 36/4-14 36/5-20 36/5-16 36/5-14 36/5-10 36/5-8 36/5-7 36/9-20 36/9-16 36/9-12 36/9-8 36/9-5 36/11-5 36/11-3 36/3-48 36/3-48 36/3-48 36/3-48 36/3-48 36/3-48 36/3-48 36/3-48 36/3-48 36/3-42 36/3-30 36/3-24 36/3-18 36/3-14 36/4-24 36/4-18 36/4-16 36/4-12 36/5-18 36/5-14 36/5-12 36/5-10 36/5-8 36/9-24 36/9-18 36/9-14 36/9-8 36/9-6 36/11-6 36/11-4 36/3-48 36/3-33 36/3-24 36/3-18 36/3-15 36/4-24 36/4-18 36/4-15 36/4-12 36/5-18 36/5-14 36/5-12 36/5-9 36/5-8 36/5-6 36/9-18 36/9-14 36/9-10 36/9-9 36/9-7 36/9-6 36/11-7 36/11-6 36/9-3 36/11-4 36/11-3 36/3-48 36/3-48 36/3-48 36/3-48 36/3-48 36/3-36 36/3-27 36/3-21 36/3-15 36/3-12 36/4-21 36/4-16 36/4-14 36/5-20 36/4-9 36/5-12 36/5-9 36/9-42 36/5-6 36/9-20 36/9-16 36/9-12 36/9-10 36/9-8 36/9-6 36/11-8 36/9-3 36/11-3 36/4-48 36/4-48 36/4-48 36/4-48 36/4-48 36/4-48 36/4-48 36/4-48 36/4-48 36/4-48 36/4-45 36/4-33 36/4-27 36/4-21 36/4-18 36/4-15 36/4-12 36/4-9 36/5-12 36/5-11 36/5-9 36/5-7 36/5-6 36/9-15 36/9-12 36/9-9 36/9-7 36/11-7 36/11-4 36/11-3 36/4-48 36/4-48 36/4-36 36/4-24 36/4-20 36/4-18 36/4-14 36/4-12 36/5-16 36/5-14 36/9-48 36/9-48 36/9-30 36/9-20 36/9-16 36/9-12 36/9-10 36/9-8 36/9-7 36/11-8 36/11-7 36/11-6 36/4-48 36/4-48 36/4-48 36/4-48 36/4-48 36/4-48 36/4-48 36/4-36 36/4-24 36/4-20 36/4-18 36/4-14 36/4-12 36/5-18 36/5-14 36/5-12 36/9-42 36/9-30 36/9-20 36/9-16 36/9-12 36/9-10 36/9-8 36/9-7 36/9-6 36/11-7 36/4-48 36/4-48 36/4-48 36/4-48 36/4-48 36/4-48 36/4-48 36/4-48 36/4-42 36/4-36 36/4-24 36/4-20 36/4-18 36/4-14 36/4-12 36/5-18 36/5-14 36/5-12 36/7-16 36/9-24 36/9-20 36/7-10 36/9-12 36/9-10 36/9-8 36/9-7 36/11-7 * Please refer to footnotes listed at the end of this section on page 60. Allowable diaphragm design strength, plf* SASD SASD (wind) (seismic) 254 270 272 289 291 309 311 331 333 354 356 379 381 406 408 434 437 464 467 497 500 532 535 569 572 609 612 651 655 697 701 746 750 798 802 854 859 914 919 977 983 1046 1052 1119 1126 1197 1204 1281 1289 1371 1379 1467 1579 1679 1807 1923 2069 2201 2369 2520 Span = 4'-6'' Recommended Hilti powder-actuated frame fastener pattern-sidelap spacing Hilti SLC (in. o.c.)* X-ENP-19 with tf ≥ 1/4" X-HSN 24 with 3/16" ≤ tf ≤ 3/8" X-HSN 24 with 1/8" ≤ tf < 3/16" 22 ga. 20 ga. 18 ga. 16 ga. 22 ga. 20 ga. 18 ga. 22 ga. 20 ga. 18 ga. 36/3-54 36/3-54 36/3-42 36/3-30 36/3-24 36/3-20 36/3-16 36/4-24 36/4-18 36/4-16 36/4-12 36/5-18 36/5-14 36/5-12 36/5-10 36/5-8 36/5-7 36/9-18 36/9-14 36/9-10 36/9-8 36/9-7 36/9-6 36/9-5 36/11-6 36/11-5 36/11-3 36/3-54 36/3-54 36/3-54 36/3-54 36/3-54 36/3-54 36/3-42 36/3-30 36/3-24 36/3-20 36/3-16 36/4-24 36/4-20 36/4-16 36/4-12 36/5-18 36/5-14 36/5-12 36/5-10 36/5-8 36/5-7 36/9-18 36/9-14 36/9-10 36/9-8 36/9-7 36/9-5 36/11-5 36/11-3 36/3-54 36/3-54 36/3-54 36/3-54 36/3-54 36/3-54 36/3-54 36/3-54 36/3-54 36/3-42 36/3-30 36/3-24 36/3-20 36/3-14 36/4-24 36/4-18 36/4-16 36/4-12 36/5-18 36/5-14 36/5-12 36/5-10 36/5-8 36/5-7 36/9-16 36/9-12 36/9-8 36/9-6 36/11-6 36/11-4 36/3-54 36/3-54 36/3-54 36/3-54 36/3-54 36/3-54 36/3-54 36/3-54 36/3-54 36/3-42 36/3-36 36/3-24 36/3-20 36/3-16 36/4-24 36/4-20 36/4-18 36/4-14 36/4-12 36/5-16 36/5-12 36/5-10 36/5-8 36/5-7 36/9-18 36/9-14 36/9-10 36/9-6 36/11-6 36/11-4 36/3-51 36/3-36 36/3-27 36/3-21 36/3-16 36/3-12 36/4-20 36/4-16 36/4-14 36/5-18 36/5-16 36/5-12 36/5-10 36/5-9 36/5-7 36/5-6 36/9-15 36/9-12 36/9-9 36/9-8 36/9-6 36/9-5 36/11-6 36/9-3 36/9-3 36/11-3 36/3-54 36/3-54 36/3-54 36/3-54 36/3-54 36/3-39 36/3-30 36/3-24 36/3-18 36/3-15 36/4-21 36/4-18 36/4-15 36/4-12 36/5-16 36/5-14 36/5-12 36/5-10 36/5-7 36/9-19 36/9-16 36/9-12 36/9-10 36/9-8 36/9-7 36/9-6 36/11-6 36/11-4 36/4-54 36/4-54 36/4-54 36/4-54 36/4-54 36/4-54 36/4-54 36/4-54 36/4-54 36/4-54 36/4-45 36/4-36 36/4-30 36/4-24 36/4-20 36/4-15 36/4-12 36/5-18 36/5-15 36/5-12 36/5-10 36/5-8 36/5-6 36/9-15 36/9-12 36/9-9 36/9-7 36/11-7 36/11-5 36/11-3 36/4-54 36/4-48 36/4-36 36/4-30 36/4-24 36/4-20 36/4-16 36/4-14 36/5-18 36/5-14 36/5-12 36/9-42 36/9-30 36/9-20 36/9-18 36/9-14 36/9-10 36/9-8 36/9-7 36/9-6 36/11-7 36/11-6 36/4-54 36/4-54 36/4-54 36/4-54 36/4-54 36/4-54 36/4-48 36/4-36 36/4-30 36/4-24 36/4-20 36/4-16 36/4-14 36/5-18 36/5-16 36/5-12 36/9-42 36/9-30 36/9-20 36/9-18 36/9-14 36/9-12 36/9-8 36/9-8 36/9-6 36/11-8 36/4-54 36/4-54 36/4-54 36/4-54 36/4-54 36/4-54 36/4-54 36/4-54 36/4-48 36/4-36 36/4-30 36/4-24 36/4-20 36/4-18 36/4-14 36/5-20 36/5-16 36/5-14 36/9-36 36/7-14 36/7-12 36/9-18 36/9-14 36/9-12 36/9-10 36/9-8 36/11-8 * Please refer to footnotes listed at the end of this section on page 60. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 55 Steel Deck Fastening Systems 1.6 Optimized Diaphragm Shear Tables Allowable diaphragm design strength, plf* SASD SASD (wind) (seismic) 237 253 254 270 272 289 291 309 311 331 333 354 356 379 381 406 408 434 437 464 467 497 500 532 535 569 572 609 612 651 655 697 701 746 750 798 802 854 859 914 919 977 983 1046 1052 1119 1126 1197 1204 1281 1289 1371 1475 1570 1689 1797 1934 2057 2214 2355 Span = 5'-0'' Recommended Hilti powder-actuated frame fastener pattern-sidelap spacing Hilti SLC (in. o.c.)* X-ENP-19 with tf ≥ 1/4" X-HSN 24 with 3/16" ≤ tf ≤ 3/8" X-HSN 24 with 1/8" ≤ tf < 3/16" 22 ga. 20 ga. 18 ga. 16 ga. 22 ga. 20 ga. 18 ga. 22 ga. 20 ga. 18 ga. 36/3-60 36/3-60 36/3-48 36/3-36 36/3-30 36/3-24 36/3-18 36/3-14 36/3-12 36/4-18 36/4-14 36/4-12 36/5-16 36/5-12 36/5-10 36/5-8 36/5-8 36/9-18 36/9-14 36/9-12 36/9-10 36/9-8 36/9-7 36/11-8 36/11-6 36/9-4 36/11-4 36/3-60 36/3-60 36/3-60 36/3-60 36/3-60 36/3-60 36/3-48 36/3-36 36/3-30 36/3-24 36/3-18 36/3-14 36/3-12 36/4-18 36/4-14 36/4-12 36/5-16 36/5-14 36/5-12 36/5-10 36/5-8 36/5-7 36/9-14 36/9-12 36/9-10 36/9-8 36/9-6 36/9-4 36/11-4 36/11-3 36/3-60 36/3-60 36/3-60 36/3-60 36/3-60 36/3-60 36/3-60 36/3-60 36/3-60 36/3-42 36/3-36 36/3-24 36/3-20 36/3-18 36/3-14 36/4-20 36/4-18 36/4-14 36/4-12 36/5-16 36/5-14 36/5-10 36/5-8 36/5-8 36/9-18 36/9-14 36/9-10 36/9-7 36/9-5 36/11-5 36/3-60 36/3-60 36/3-60 36/3-60 36/3-60 36/3-60 36/3-60 36/3-60 36/3-60 36/3-48 36/3-36 36/3-30 36/3-24 36/3-20 36/3-16 36/3-12 36/4-18 36/4-16 36/4-14 36/5-18 36/5-14 36/5-12 36/5-10 36/5-8 36/5-7 36/9-16 36/9-10 36/9-7 36/9-5 36/11-5 36/3-51 36/3-39 36/3-30 36/3-24 36/3-20 36/3-16 36/3-12 36/4-18 36/4-15 36/4-12 36/4-11 36/4-9 36/5-12 36/5-10 36/5-8 36/5-6 36/9-15 36/9-12 36/9-10 36/9-8 36/9-7 36/9-6 36/11-7 36/11-6 36/9-3 36/11-4 36/11-3 36/3-60 36/3-60 36/3-60 36/3-60 36/3-57 36/3-45 36/3-35 36/3-27 36/3-21 36/3-18 36/3-14 36/4-20 36/4-16 36/4-14 36/4-12 36/5-16 36/5-12 36/5-11 36/5-9 36/5-7 36/5-6 36/9-14 36/9-10 36/9-9 36/9-8 36/9-6 36/11-6 36/11-4 36/11-3 36/4-60 36/4-60 36/4-60 36/4-60 36/4-60 36/4-60 36/4-60 36/4-60 36/4-60 36/4-60 36/4-48 36/4-39 36/4-30 36/4-24 36/4-21 36/4-18 36/4-15 36/4-12 36/5-15 36/5-14 36/5-12 36/5-9 36/7-12 36/7-10 36/9-15 36/9-12 36/9-8 36/9-6 36/11-6 36/11-4 36/4-60 36/4-48 36/4-36 36/4-30 36/4-24 36/4-20 36/4-18 36/5-24 36/5-20 36/5-16 36/5-14 36/5-12 36/9-30 36/9-24 36/9-18 36/9-14 36/9-12 36/9-10 36/9-8 36/9-7 36/9-6 36/11-7 36/11-6 36/4-60 36/4-60 36/4-60 36/4-60 36/4-60 36/4-60 36/4-48 36/4-36 36/4-30 36/4-24 36/4-20 36/4-18 36/4-16 36/5-20 36/5-16 36/5-14 36/5-12 36/9-30 36/9-24 36/9-18 36/9-14 36/9-12 36/9-10 36/9-8 36/9-7 36/9-6 36/11-6 36/4-60 36/4-60 36/4-60 36/4-60 36/4-60 36/4-60 36/4-60 36/4-60 36/4-48 36/4-36 36/4-30 36/4-24 36/4-24 36/4-20 36/4-16 36/4-14 36/5-18 36/5-14 36/5-12 36/7-16 36/7-14 36/7-12 36/9-16 36/9-12 36/9-10 36/9-8 36/9-6 36/11-6 * Please refer to footnotes listed at the end of this section on page 60. Allowable diaphragm design strength, plf* SASD SASD (wind) (seismic) 222 236 237 253 254 270 272 289 291 309 311 331 333 354 356 379 381 406 408 434 437 464 467 497 500 532 535 569 572 609 612 651 655 697 701 746 750 798 802 854 859 914 919 977 983 1046 1052 1119 1126 1197 1204 1281 1379 1467 1579 1679 1807 1923 2069 2201 Span = 5'-6'' Recommended Hilti powder-actuated frame fastener pattern-sidelap spacing Hilti SLC (in. o.c.)* X-ENP-19 with tf ≥ 1/4" X-HSN 24 with 3/16" ≤ tf ≤ 3/8" X-HSN 24 with 1/8" ≤ tf < 3/16" 22 ga. 20 ga. 18 ga. 16 ga. 22 ga. 20 ga. 18 ga. 22 ga. 20 ga. 18 ga. 36/3-66 36/3-66 36/3-48 36/3-42 36/3-30 36/3-24 36/3-20 36/3-18 36/3-14 36/4-18 36/4-16 36/4-14 36/4-12 36/4-10 36/5-12 36/5-10 36/5-8 36/5-7 36/9-14 36/9-12 36/9-10 36/9-8 36/9-7 36/9-6 36/9-5 36/11-6 36/11-4 36/11-3Z 36/3-66 36/3-66 36/3-66 36/3-66 36/3-66 36/3-60 36/3-48 36/3-42 36/3-30 36/3-24 36/3-20 36/3-18 36/4-24 36/4-20 36/4-16 36/4-14 36/4-12 36/4-10 36/5-12 36/5-10 36/5-8 36/5-8 36/9-16 36/9-12 36/9-10 36/9-8 36/9-6 36/11-6 36/11-4 36/11-3 36/3-66 36/3-66 36/3-66 36/3-66 36/3-66 36/3-66 36/3-66 36/3-66 36/3-60 36/3-48 36/3-36 36/3-30 36/3-24 36/3-20 36/3-16 36/3-14 36/4-20 36/4-16 36/4-14 36/4-12 36/4-10 36/5-12 36/5-10 36/5-8 36/5-8 36/9-14 36/9-10 36/9-7 36/9-5 36/9-4 36/3-66 36/3-66 36/3-66 36/3-66 36/3-66 36/3-66 36/3-66 36/3-66 36/3-66 36/3-48 36/3-42 36/3-36 36/3-24 36/3-20 36/3-18 36/4-24 36/4-20 36/4-18 36/4-14 36/4-12 36/5-16 36/5-14 36/5-12 36/5-10 36/5-8 36/5-7 36/9-12 36/9-8 36/9-6 36/11-6 36/3-57 36/3-42 36/3-33 36/3-27 36/3-21 36/3-18 36/3-15 36/3-12 36/4-16 36/4-14 36/4-12 36/5-15 36/5-12 36/5-10 36/5-9 36/5-8 36/5-6 36/9-12 36/9-10 36/9-9 36/9-8 36/9-6 36/11-7 36/11-6 36/9-4 36/9-3 36/11-3 36/3-66 36/3-66 36/3-66 36/3-66 36/3-63 36/3-48 36/3-39 36/3-30 36/3-24 36/3-21 36/3-15 36/4-21 36/4-18 36/4-16 36/4-12 36/4-11 36/4-9 36/5-12 36/5-10 36/5-9 36/5-7 36/5-6 36/9-12 36/9-10 36/9-8 36/9-7 36/11-7 36/11-5 36/11-3 36/4-66 36/4-66 36/4-66 36/4-66 36/4-66 36/4-66 36/4-66 36/4-66 36/4-66 36/4-66 36/4-51 36/4-42 36/4-33 36/4-27 36/4-24 36/4-18 36/4-15 36/5-21 36/4-12 36/5-15 36/5-12 36/5-11 36/5-9 36/9-18 36/5-6 36/9-12 36/9-9 36/9-6 36/11-6 36/11-4 36/4-60 36/4-48 36/4-42 36/4-30 36/4-24 36/4-24 36/4-20 36/4-16 36/4-14 36/5-18 36/5-16 36/5-12 36/9-30 36/9-24 36/9-20 36/9-16 36/9-12 36/9-10 36/9-8 36/9-8 36/9-6 36/11-7 36/11-6 36/4-66 36/4-66 36/4-66 36/4-66 36/4-66 36/4-60 36/4-48 36/4-42 36/4-36 36/4-30 36/4-24 36/4-20 36/4-18 36/4-14 36/5-18 36/5-16 36/5-14 36/5-12 36/9-24 36/9-20 36/9-16 36/9-14 36/7-8 36/9-10 36/9-8 36/9-7 36/11-6 36/4-66 36/4-66 36/4-66 36/4-66 36/4-66 36/4-66 36/4-66 36/4-60 36/4-48 36/4-42 36/4-36 36/4-30 36/4-24 36/4-20 36/4-18 36/4-16 36/5-20 36/5-16 36/5-14 36/5-12 36/9-24 36/9-20 36/9-16 36/9-14 36/9-12 36/9-10 36/9-7 36/11-7 * Please refer to footnotes listed at the end of this section on page 60. 56 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 Steel Deck Fastening Systems Optimized Diaphragm Shear Tables 1.6 Allowable diaphragm design strength, plf* SASD SASD (wind) (seismic) 207 221 222 236 237 253 254 270 272 289 291 309 311 331 333 354 356 379 381 406 408 434 437 464 467 497 500 532 535 569 572 609 612 651 655 697 701 746 750 798 802 854 859 914 919 977 983 1046 1052 1119 1126 1197 1289 1371 1475 1570 1689 1797 1934 2057 Span = 6'-0'' Recommended Hilti powder-actuated frame fastener pattern-sidelap spacing Hilti SLC (in. o.c.)* X-ENP-19 with tf ≥ 1/4" X-HSN 24 with 3/16" ≤ tf ≤ 3/8" X-HSN 24 with 1/8" ≤ tf < 3/16" 22 ga. 20 ga. 18 ga. 16 ga. 22 ga. 20 ga. 18 ga. 22 ga. 20 ga. 18 ga. 36/3-72 36/3-72 36/3-48 36/3-42 36/3-36 36/3-30 36/3-24 36/3-20 36/3-16 36/4-20 36/4-18 36/4-14 36/4-12 36/5-16 36/5-14 36/5-12 36/5-10 36/5-8 36/5-7 36/9-14 36/9-10 36/9-8 36/9-8 36/9-7 36/9-6 36/9-5 36/11-5 36/11-3 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-48 36/3-42 36/3-36 36/3-30 36/3-24 36/3-20 36/3-16 36/3-14 36/4-18 36/4-16 36/4-14 36/4-12 36/4-10 36/5-12 36/5-10 36/5-8 36/5-7 36/9-14 36/9-12 36/9-10 36/9-7 36/11-7 36/11-5 36/11-3 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-48 36/3-42 36/3-36 36/3-30 36/3-24 36/3-20 36/3-16 36/4-20 36/4-18 36/4-16 36/4-12 36/5-16 36/5-14 36/5-12 36/5-10 36/5-8 36/5-7 36/9-12 36/9-8 36/9-6 36/11-6 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-60 36/3-48 36/3-36 36/3-30 36/3-24 36/3-20 36/3-18 36/4-24 36/4-20 36/4-16 36/4-14 36/4-12 36/4-10 36/5-12 36/5-10 36/5-8 36/5-8 36/9-12 36/9-8 36/9-7 36/9-5 36/3-60 36/3-48 36/3-39 36/3-30 36/3-24 36/3-21 36/3-16 36/3-14 36/4-18 36/4-16 36/4-14 36/4-12 36/4-10 36/5-12 36/5-10 36/5-9 36/5-7 36/5-6 36/9-12 36/9-10 36/9-8 36/9-7 36/9-6 36/11-7 36/11-6 36/11-5 36/11-3 36/3-72 36/3-72 36/3-72 36/3-72 36/3-69 36/3-54 36/3-42 36/3-33 36/3-29 36/3-21 36/3-19 36/3-18 36/4-21 36/4-18 36/4-15 36/4-12 36/4-11 36/4-9 36/5-12 36/5-9 36/9-18 36/9-16 36/9-12 36/9-10 36/9-9 36/9-8 36/9-6 36/9-4 36/11-4 36/11-3 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-69 36/4-55 36/4-45 36/4-36 36/4-30 36/4-24 36/4-21 36/4-18 36/4-16 36/4-14 36/4-12 36/4-9 36/5-12 36/5-11 36/5-9 36/9-16 36/9-13 36/9-10 36/9-7 36/9-5 36/11-5 36/4-60 36/4-48 36/4-42 36/4-36 36/4-30 36/4-24 36/4-20 36/4-18 36/4-16 36/4-14 36/4-12 36/5-14 36/5-12 36/9-24 36/9-20 36/9-16 36/9-14 36/9-12 36/9-10 36/9-8 36/9-7 36/9-6 36/11-7 36/11-6 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-60 36/4-48 36/4-42 36/4-36 36/4-30 36/4-24 36/4-20 36/4-20 36/4-16 36/4-14 36/5-18 36/5-14 36/5-12 36/9-24 36/9-20 36/9-18 36/9-14 36/9-12 36/9-10 36/9-8 36/9-8 36/11-7 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-60 36/4-48 36/4-48 36/4-36 36/4-30 36/4-30 36/4-24 36/4-20 36/4-18 36/4-14 36/5-18 36/5-16 36/5-14 36/5-12 36/7-14 36/9-18 36/9-16 36/9-12 36/7-8 36/9-8 36/9-6 36/11-6 * Please refer to footnotes listed at the end of this section on page 60. Allowable diaphragm design strength, plf* SASD SASD (wind) (seismic) 194 206 207 221 222 236 237 253 254 270 272 289 291 309 311 331 333 354 356 379 381 406 408 434 437 464 467 497 500 532 535 569 572 609 612 651 655 697 701 746 750 798 802 854 859 914 919 977 983 1046 1052 1119 1204 1281 1379 1467 1579 1679 1807 1923 Span = 6'-6'' Recommended Hilti powder-actuated frame fastener pattern-sidelap spacing Hilti SLC (in. o.c.)* X-ENP-19 with tf ≥ 1/4" X-HSN 24 with 3/16" ≤ tf ≤ 3/8" X-HSN 24 with 1/8" ≤ tf < 3/16" 22 ga. 20 ga. 18 ga. 16 ga. 22 ga. 20 ga. 18 ga. 22 ga. 20 ga. 18 ga. 36/3-72 36/3-72 36/3-60 36/3-48 36/3-36 36/3-30 36/3-24 36/3-20 36/3-18 36/3-16 36/4-20 36/4-16 36/4-14 36/5-18 36/5-14 36/5-12 36/4-8 36/5-10 36/5-8 36/5-7 36/9-12 36/9-10 36/9-8 36/9-8 36/9-6 36/11-7 36/9-4 36/11-4 36/11-3 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-60 36/3-48 36/3-36 36/3-30 36/3-24 36/3-24 36/3-20 36/3-16 36/4-20 36/4-18 36/4-14 36/5-18 36/5-16 36/5-14 36/5-12 36/5-10 36/5-8 36/5-7 36/9-12 36/7-8 36/9-8 36/9-6 36/9-4 36/11-4 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-60 36/3-48 36/3-36 36/3-30 36/3-24 36/3-20 36/3-18 36/3-16 36/4-20 36/4-18 36/4-14 36/5-18 36/5-16 36/5-12 36/5-12 36/5-10 36/5-8 36/9-12 36/7-7 36/9-7 36/9-5 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-60 36/3-48 36/3-42 36/3-36 36/3-30 36/3-24 36/3-20 36/3-16 36/3-14 36/4-18 36/4-16 36/4-14 36/4-12 36/5-14 36/5-12 36/5-10 36/9-20 36/9-14 36/9-10 36/9-7 36/11-7 36/3-69 36/3-51 36/3-42 36/3-33 36/3-27 36/3-24 36/3-18 36/3-16 36/4-21 36/4-18 36/4-15 36/4-12 36/4-11 36/4-9 36/5-12 36/5-9 36/5-8 36/5-7 36/5-6 36/9-10 36/9-9 36/9-8 36/9-7 36/9-6 36/9-5 36/9-4 36/9-3 36/11-3 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-57 36/3-48 36/3-39 36/3-30 36/3-27 36/3-21 36/3-18 36/3-15 36/3-12 36/4-16 36/4-15 36/4-12 36/5-15 36/5-12 36/5-11 36/5-9 36/9-16 36/5-7 36/5-6 36/9-10 36/9-8 36/9-6 36/9-5 36/11-4 36/11-3 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-57 36/4-48 36/4-39 36/4-33 36/4-27 36/4-24 36/4-21 36/4-18 36/4-15 36/4-12 36/5-15 36/4-9 36/5-12 36/5-9 36/5-9 36/9-15 36/9-9 36/9-8 36/9-6 36/11-6 36/4-60 36/4-48 36/4-48 36/4-36 36/4-30 36/4-24 36/4-24 36/4-20 36/4-18 36/4-16 36/5-18 36/5-16 36/5-14 36/5-12 36/9-20 36/9-18 36/9-14 36/9-12 36/9-10 36/7-7 36/9-8 36/9-7 36/9-6 36/11-7 36/11-6 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-60 36/4-48 36/4-42 36/4-30 36/4-30 36/4-24 36/4-20 36/4-18 36/4-16 36/4-14 36/4-12 36/5-14 36/5-12 36/7-14 36/9-18 36/9-16 36/9-14 36/9-12 36/9-10 36/9-8 36/9-6 36/11-6 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-60 36/4-48 36/4-42 36/4-36 36/4-30 36/4-24 36/4-24 36/4-20 36/4-18 36/4-14 36/5-18 36/5-16 36/5-14 36/5-12 36/7-14 36/7-12 36/9-14 36/9-12 36/7-7 36/9-7 36/11-7 * Please refer to footnotes listed at the end of this section on page 60. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 57 Steel Deck Fastening Systems 1.6 Optimized Diaphragm Shear Tables Allowable diaphragm design strength, plf* SASD SASD (wind) (seismic) 194 206 207 221 222 236 237 253 254 270 272 289 291 309 311 331 333 354 356 379 381 406 408 434 437 464 467 497 500 532 535 569 572 609 612 651 655 697 701 746 750 798 802 854 859 914 919 977 983 1046 1052 1119 1204 1281 1379 1467 1579 1679 1807 1923 Span = 7'-0'' Recommended Hilti powder-actuated frame fastener pattern-sidelap spacing Hilti SLC (in. o.c.)* X-ENP-19 with tf ≥ 1/4" X-HSN 24 with 3/16" ≤ tf ≤ 3/8" X-HSN 24 with 1/8" ≤ tf < 3/16" 22 ga. 20 ga. 18 ga. 16 ga. 22 ga. 20 ga. 18 ga. 22 ga. 20 ga. 18 ga. 36/3-72 36/3-60 36/3-48 36/3-42 36/3-36 36/3-30 36/3-24 36/3-20 36/3-18 36/3-14 36/4-18 36/4-16 36/4-14 36/4-12 36/5-14 36/5-12 36/5-10 36/9-18 36/5-8 36/5-7 36/5-6 36/9-10 36/9-8 36/9-7 36/9-6 36/11-7 36/11-5 36/11-4 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-60 36/3-48 36/3-42 36/3-36 36/3-30 36/3-24 36/3-20 36/3-18 36/3-16 36/4-20 36/4-16 36/4-14 36/4-12 36/5-14 36/5-12 36/4-8 36/5-10 36/5-8 36/9-14 36/9-12 36/9-10 36/9-8 36/9-6 36/11-5 36/11-4 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-60 36/3-48 36/3-42 36/3-36 36/3-30 36/3-24 36/3-20 36/3-18 36/3-14 36/4-20 36/4-16 36/4-14 36/4-12 36/5-14 36/5-12 36/5-10 36/5-10 36/5-8 36/9-12 36/9-8 36/9-6 36/9-5 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-60 36/3-48 36/3-36 36/3-30 36/3-24 36/3-24 36/3-20 36/3-16 36/3-14 36/4-18 36/4-16 36/4-14 36/4-12 36/5-14 36/5-12 36/5-10 36/9-18 36/9-12 36/9-10 36/9-7 36/11-7 36/3-57 36/3-47 36/3-36 36/3-30 36/3-27 36/3-21 36/3-18 36/3-16 36/3-12 36/4-16 36/4-15 36/4-12 36/5-15 36/5-12 36/5-11 36/5-10 36/5-8 36/5-7 36/5-6 36/9-10 36/9-9 36/9-7 36/9-6 36/9-6 36/11-6 36/7-3 36/9-3 36/11-3 36/3-72 36/3-72 36/3-72 36/3-72 36/3-63 36/3-51 36/3-42 36/3-36 36/3-30 36/3-24 36/3-21 36/3-18 36/3-15 36/4-18 36/4-16 36/4-14 36/4-12 36/5-14 36/5-12 36/5-11 36/5-9 36/9-16 36/9-12 36/9-10 36/9-10 36/7-6 36/9-6 36/11-6 36/11-4 36/11-3 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-63 36/4-51 36/4-42 36/4-36 36/4-30 36/4-27 36/4-21 36/4-20 36/4-17 36/4-15 36/5-18 36/5-15 36/5-12 36/5-11 36/5-10 36/9-15 36/9-12 36/9-9 36/9-8 36/9-6 36/9-4 36/4-60 36/4-48 36/4-42 36/4-36 36/4-30 36/4-24 36/4-20 36/4-20 36/4-16 36/4-14 36/5-18 36/5-14 36/5-12 36/9-24 36/9-20 36/9-16 36/9-14 36/9-12 36/9-10 36/7-7 36/9-8 36/9-7 36/9-6 36/11-6 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-60 36/4-48 36/4-42 36/4-36 36/4-30 36/4-24 36/4-24 36/4-20 36/4-18 36/4-16 36/4-14 36/4-12 36/5-14 36/5-12 36/9-20 36/9-18 36/9-14 36/9-12 36/9-10 36/7-7 36/9-8 36/11-8 36/11-6 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-60 36/4-48 36/4-48 36/4-42 36/4-36 36/4-30 36/4-24 36/4-20 36/4-20 36/4-16 36/4-14 36/5-18 36/5-14 36/5-12 36/7-14 36/9-18 36/7-12 36/9-14 36/9-12 36/7-7 36/9-7 36/11-6 * Please refer to footnotes listed at the end of this section on page 60. Allowable diaphragm design strength, plf* SASD SASD (wind) (seismic) 181 193 194 206 207 221 222 236 237 253 254 270 272 289 291 309 311 331 333 354 356 379 381 406 408 434 437 464 467 497 500 532 535 569 572 609 612 651 655 697 701 746 750 798 802 854 859 914 919 977 983 1046 1126 1197 1289 1371 1475 1570 1689 1797 Span = 7'-6'' Recommended Hilti powder-actuated frame fastener pattern-sidelap spacing Hilti SLC (in. o.c.)* X-ENP-19 with tf ≥ 1/4" X-HSN 24 with 3/16" ≤ tf ≤ 3/8" X-HSN 24 with 1/8" ≤ tf < 3/16" 22 ga. 20 ga. 18 ga. 16 ga. 22 ga. 20 ga. 18 ga. 22 ga. 20 ga. 18 ga. 36/3-72 36/3-72 36/3-60 36/3-48 36/3-36 36/3-30 36/3-24 36/3-24 36/3-20 36/3-18 36/3-14 36/4-18 36/4-16 36/4-14 36/5-16 36/5-14 36/5-12 36/5-10 36/5-8 36/5-8 36/5-7 36/5-6 36/7-7 36/9-8 36/9-7 36/9-6 36/11-6 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-60 36/3-48 36/3-42 36/3-36 36/3-30 36/3-24 36/3-20 36/3-18 36/3-14 36/4-18 36/4-16 36/4-14 36/5-16 36/5-14 36/5-12 36/5-10 36/9-18 36/5-8 36/5-7 36/5-6 36/9-8 36/11-8 36/9-5 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-60 36/3-48 36/3-42 36/3-30 36/3-30 36/3-24 36/3-20 36/3-18 36/3-14 36/4-18 36/4-16 36/4-14 36/5-16 36/5-14 36/5-12 36/5-10 36/9-18 36/5-7 36/9-10 36/9-7 36/11-7 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-60 36/3-48 36/3-42 36/3-36 36/3-30 36/3-24 36/3-20 36/3-20 36/3-16 36/4-20 36/4-18 36/5-20 36/5-18 36/5-16 36/5-14 36/5-12 36/5-10 36/9-14 36/7-8 36/9-8 36/9-6 36/3-63 36/3-51 36/3-42 36/3-36 36/3-30 36/3-24 36/3-21 36/3-18 36/3-15 36/4-18 36/4-16 36/4-14 36/5-16 36/5-14 36/5-12 36/5-10 36/5-9 36/5-8 36/5-7 36/9-12 36/9-10 36/7-6 36/9-7 36/9-6 36/11-7 36/9-5 36/9-3 36/3-72 36/3-72 36/3-72 36/3-72 36/3-69 36/3-57 36/3-45 36/3-39 36/3-33 36/3-27 36/3-24 36/3-18 36/3-15 36/4-21 36/4-18 36/4-16 36/4-14 36/5-16 36/5-14 36/5-12 36/5-10 36/5-9 36/9-15 36/9-12 36/9-10 36/7-7 36/9-7 36/7-4 36/9-4 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-66 36/4-54 36/4-48 36/4-39 36/4-33 36/4-30 36/4-24 36/4-21 36/4-18 36/5-22 36/5-20 36/4-12 36/5-15 36/5-12 36/5-11 36/5-9 36/9-15 36/5-6 36/9-9 36/9-6 36/9-5 36/4-60 36/4-48 36/4-42 36/4-36 36/4-30 36/4-30 36/4-24 36/4-20 36/4-18 36/4-16 36/5-20 36/5-16 36/5-14 36/5-12 36/7-14 36/9-18 36/9-16 36/9-12 36/9-12 36/9-10 36/9-8 36/9-7 36/11-8 36/9-6 36/11-6 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-60 36/4-48 36/4-48 36/4-42 36/4-36 36/4-30 36/4-24 36/4-20 36/4-20 36/4-18 36/5-20 36/5-18 36/5-16 36/5-12 36/5-12 36/9-18 36/9-16 36/9-14 36/9-12 36/9-10 36/7-7 36/9-7 36/11-6 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-60 36/4-48 36/4-42 36/4-36 36/4-30 36/4-30 36/4-24 36/4-20 36/4-20 36/4-16 36/5-20 36/5-16 36/5-14 36/5-12 36/7-14 36/9-18 36/9-14 36/7-10 36/9-10 36/9-7 36/11-7 * Please refer to footnotes listed at the end of this section on page 60. 58 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 Steel Deck Fastening Systems Optimized Diaphragm Shear Tables 1.6 Allowable diaphragm design strength, plf* SASD SASD (wind) (seismic) 181 193 194 206 207 221 222 236 237 253 254 270 272 289 291 309 311 331 333 354 356 379 381 406 408 434 437 464 467 497 500 532 535 569 572 609 612 651 655 697 701 746 750 798 802 854 859 914 919 977 983 1046 1126 1197 1289 1371 1475 1570 1689 1797 Span = 8'-0'' Recommended Hilti powder-actuated frame fastener pattern-sidelap spacing Hilti SLC (in. o.c.)* X-ENP-19 with tf ≥ 1/4" X-HSN 24 with 3/16" ≤ tf ≤ 3/8" X-HSN 24 with 1/8" ≤ tf < 3/16" 22 ga. 20 ga. 18 ga. 16 ga. 22 ga. 20 ga. 18 ga. 22 ga. 20 ga. 18 ga. 36/3-72 36/3-60 36/3-48 36/3-42 36/3-36 36/3-30 36/3-24 36/3-20 36/3-20 36/3-16 36/4-20 36/4-16 36/5-20 36/5-16 36/5-14 36/4-10 36/5-12 36/5-10 36/5-8 36/5-8 36/9-12 36/9-10 36/7-7 36/9-8 36/9-7 36/9-6 36/11-5 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-60 36/3-48 36/3-42 36/3-36 36/3-30 36/3-24 36/3-24 36/3-20 36/3-18 36/4-20 36/4-18 36/4-16 36/4-14 36/5-16 36/5-14 36/5-12 36/5-10 36/5-8 36/5-8 36/5-7 36/7-8 36/9-8 36/9-6 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-60 36/3-48 36/3-42 36/3-36 36/3-30 36/3-24 36/3-24 36/3-20 36/4-24 36/4-20 36/4-18 36/4-16 36/4-14 36/5-16 36/5-14 36/5-12 36/5-10 36/5-8 36/5-7 36/7-7 36/9-7 36/9-5 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-60 36/3-48 36/3-42 36/3-36 36/3-30 36/3-24 36/3-20 36/3-18 36/3-16 36/4-20 36/4-16 36/5-20 36/5-16 36/5-14 36/4-10 36/5-10 36/5-10 36/7-10 36/7-8 36/9-8 36/9-6 36/3-54 36/3-48 36/3-39 36/3-33 36/3-27 36/3-24 36/3-21 36/3-18 36/3-15 36/4-18 36/4-16 36/4-14 36/4-12 36/5-14 36/5-12 36/5-10 36/5-9 36/5-8 36/5-7 36/5-6 36/7-7 36/7-6 36/9-7 36/9-6 36/9-5 36/11-6 36/3-72 36/3-72 36/3-72 36/3-72 36/3-63 36/3-51 36/3-45 36/3-36 36/3-30 36/3-27 36/3-21 36/3-18 36/3-15 36/4-20 36/4-18 36/4-15 36/4-13 36/4-12 36/4-10 36/5-12 36/5-10 36/5-9 36/9-14 36/9-12 36/9-10 36/7-7 36/9-7 36/9-5 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-69 36/4-60 36/4-51 36/4-42 36/4-36 36/4-33 36/4-27 36/4-24 36/4-21 36/4-18 36/4-15 36/4-14 36/4-12 36/5-14 36/5-12 36/5-11 36/5-9 36/5-8 36/5-6 36/9-8 36/9-6 36/9-5 36/4-48 36/4-48 36/4-42 36/4-36 36/4-30 36/4-24 36/4-24 36/4-20 36/4-18 36/4-16 36/4-14 36/5-16 36/5-14 36/5-12 36/9-20 36/7-12 36/9-14 36/9-12 36/9-10 36/9-10 36/9-8 36/9-7 36/11-8 36/11-7 36/11-6 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-60 36/4-48 36/4-42 36/4-36 36/4-30 36/4-30 36/4-24 36/4-20 36/4-20 36/4-16 36/5-20 36/5-16 36/5-14 36/5-12 36/7-14 36/9-18 36/9-14 36/7-10 36/9-12 36/9-10 36/7-7 36/9-7 36/11-6 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-60 36/4-48 36/4-48 36/4-42 36/4-36 36/4-30 36/4-24 36/4-24 36/4-20 36/4-18 36/4-16 36/4-14 36/5-16 36/5-14 36/5-12 36/7-14 36/7-12 36/9-14 36/7-10 36/9-10 36/9-7 36/11-7 * Please refer to footnotes listed at the end of this section on page 60. Allowable diaphragm design strength, plf* SASD SASD (wind) (seismic) 169 180 181 193 194 206 207 221 222 236 237 253 254 270 272 289 291 309 311 331 333 354 356 379 381 406 434 408 437 464 467 497 500 532 535 569 572 609 612 651 655 697 701 746 750 798 802 854 859 914 919 977 1052 1119 1204 1281 1379 1467 1579 1679 Span = 9'-0'' Recommended Hilti powder-actuated frame fastener pattern-sidelap spacing Hilti SLC (in. o.c.)* X-ENP-19 with tf ≥ 1/4" X-HSN 24 with 3/16" ≤ tf ≤ 3/8" X-HSN 24 with 1/8" ≤ tf < 3/16" 22 ga. 20 ga. 18 ga. 16 ga. 22 ga. 20 ga. 18 ga. 22 ga. 20 ga. 18 ga. 36/3-72 36/3-60 36/3-48 36/3-42 36/3-36 36/3-30 36/3-30 36/3-24 36/3-20 36/3-18 36/3-16 36/4-18 36/4-16 36/4-14 36/5-16 36/5-14 36/4-10 36/5-10 36/5-10 36/5-8 36/9-12 36/9-10 36/7-7 36/9-8 36/9-7 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-60 36/3-48 36/3-48 36/3-42 36/3-36 36/3-30 36/3-24 36/3-20 36/3-20 36/3-16 36/4-20 36/4-16 36/4-14 36/5-16 36/4-12 36/4-10 36/5-12 36/5-10 36/5-8 36/5-8 36/5-7 36/7-7 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-60 36/3-48 36/3-48 36/3-36 36/3-36 36/3-30 36/3-24 36/3-20 36/3-18 36/3-16 36/4-20 36/4-16 36/4-14 36/5-16 36/4-12 36/4-10 36/5-12 36/5-10 36/5-8 36/9-10 36/9-8 36/9-6 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-60 36/3-48 36/3-42 36/3-36 36/3-30 36/3-24 36/3-24 36/3-20 36/3-18 36/4-20 36/4-18 36/4-16 36/4-14 36/5-16 36/5-14 36/5-12 36/5-10 36/5-8 36/9-10 36/7-7 36/11-8 36/3-57 36/3-48 36/3-42 36/3-36 36/3-30 36/3-24 36/3-21 36/3-20 36/3-16 36/3-14 36/3-12 36/4-15 36/4-12 36/5-15 36/5-12 36/4-9 36/5-10 36/5-9 36/5-8 36/5-7 36/5-6 36/9-9 36/9-7 36/9-7 36/9-6 36/3-72 36/3-72 36/3-72 36/3-72 36/3-63 36/3-54 36/3-45 36/3-39 36/3-33 36/3-27 36/3-24 36/3-21 36/3-18 36/3-15 36/4-18 36/4-16 36/4-15 36/4-12 36/5-14 36/5-12 36/5-11 36/5-9 36/5-8 36/5-7 36/5-6 36/9-10 36/7-6 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-69 36/4-57 36/4-51 36/4-45 36/4-39 36/4-33 36/4-30 36/4-24 36/4-21 36/4-20 36/4-18 36/4-15 36/4-14 36/4-12 36/5-14 36/5-12 36/5-10 36/5-9 36/9-12 36/9-9 36/9-7 36/9-5 36/4-48 36/4-48 36/4-42 36/4-36 36/4-30 36/4-30 36/4-24 36/4-20 36/4-20 36/4-18 36/4-16 36/4-14 36/4-12 36/5-14 36/5-12 36/9-18 36/9-14 36/7-10 36/9-12 36/9-10 36/9-8 36/9-8 36/9-7 36/9-6 36/11-6 36/4-72 36/4-72 36/4-72 36/4-72 36/4-60 36/4-60 36/4-48 36/4-42 36/4-36 36/4-36 36/4-30 36/4-24 36/4-24 36/4-20 36/4-18 36/4-16 36/4-14 36/5-16 36/5-14 36/5-12 36/9-18 36/9-16 36/9-14 36/9-12 36/9-10 36/9-8 36/9-7 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-60 36/4-60 36/4-48 36/4-42 36/4-36 36/4-30 36/4-30 36/4-24 36/4-24 36/4-20 36/4-18 36/4-16 36/4-14 36/5-16 36/5-14 36/5-12 36/7-14 36/9-16 36/9-14 36/9-10 36/9-8 36/11-8 36/11-6 * Please refer to footnotes listed at the end of this section on page 60. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 59 Steel Deck Fastening Systems 1.6 Optimized Diaphragm Shear Tables Allowable diaphragm design strength, plf* SASD SASD (wind) (seismic) 138 147 148 157 158 168 169 180 181 193 194 206 207 221 222 236 237 253 254 270 272 289 291 309 311 331 333 354 356 379 381 406 408 434 437 464 467 497 500 532 535 569 572 609 612 651 655 697 701 746 750 798 859 914 983 1046 1126 1197 1289 1371 Span = 10'-0'' Recommended Hilti powder-actuated frame fastener pattern-sidelap spacing Hilti SLC (in. o.c.)* X-ENP-19 with tf ≥ 1/4" X-HSN 24 with 3/16" ≤ tf ≤ 3/8" X-HSN 24 with 1/8" ≤ tf < 3/16" 22 ga. 20 ga. 18 ga. 16 ga. 22 ga. 20 ga. 18 ga. 22 ga. 20 ga. 18 ga. 36/3-72 36/3-72 36/3-72 36/3-60 36/3-48 36/3-48 36/3-42 36/3-36 36/3-30 36/3-24 36/3-24 36/3-20 36/3-18 36/3-16 36/4-18 36/4-16 36/4-14 36/4-12 36/4-10 36/5-12 36/5-10 36/9-14 36/5-8 36/5-7 36/9-10 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-60 36/3-48 36/3-48 36/3-42 36/3-36 36/3-30 36/3-24 36/3-24 36/3-20 36/3-18 36/3-16 36/4-18 36/4-16 36/4-14 36/5-16 36/5-14 36/4-10 36/5-10 36/5-10 36/9-12 36/3-120 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-60 36/3-48 36/3-48 36/3-42 36/3-36 36/3-30 36/3-24 36/3-24 36/3-20 36/3-18 36/3-16 36/4-18 36/4-16 36/4-14 36/5-16 36/5-14 36/5-10 36/9-14 36/9-10 36/7-7 36/3-120 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-60 36/3-48 36/3-48 36/3-42 36/3-36 36/3-30 36/3-24 36/3-24 36/3-20 36/3-16 36/4-20 36/4-18 36/4-16 36/4-14 36/5-16 36/5-12 36/9-14 36/9-12 36/7-7 36/3-72 36/3-66 36/3-57 36/3-51 36/3-42 36/3-36 36/3-33 36/3-27 36/3-24 36/3-21 36/3-18 36/3-16 36/3-14 36/3-12 36/4-14 36/4-12 36/5-14 36/4-10 36/5-11 36/5-10 36/5-8 36/5-7 36/5-6 36/9-9 36/7-6 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-72 36/3-63 36/3-57 36/3-48 36/3-42 36/3-36 36/3-30 36/3-27 36/3-24 36/3-21 36/3-18 36/4-21 36/4-18 36/4-16 36/4-14 36/4-12 36/5-14 36/5-12 36/5-11 36/5-9 36/7-10 36/5-6 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-69 36/4-60 36/4-51 36/4-45 36/4-39 36/4-36 36/4-30 36/4-27 36/4-24 36/4-21 36/4-18 36/4-17 36/4-15 36/4-13 36/4-12 36/5-12 36/5-9 36/5-8 36/9-10 36/9-7 36/4-72 36/4-60 36/4-60 36/4-48 36/4-42 36/4-36 36/4-36 36/4-30 36/4-24 36/4-24 36/4-20 36/4-18 36/4-16 36/4-14 36/5-16 36/4-12 36/5-12 36/9-18 36/9-16 36/9-14 36/7-10 36/9-10 36/9-10 36/9-8 36/9-7 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-60 36/4-48 36/4-48 36/4-42 36/4-36 36/4-30 36/4-30 36/4-24 36/4-20 36/4-20 36/4-18 36/4-16 36/4-14 36/5-16 36/5-14 36/5-12 36/9-16 36/9-14 36/7-10 36/9-10 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-72 36/4-60 36/4-60 36/4-48 36/4-48 36/4-42 36/4-36 36/4-30 36/4-30 36/4-24 36/4-20 36/4-20 36/4-18 36/4-16 36/5-18 36/5-16 36/5-14 36/5-12 36/7-12 36/9-12 36/9-8 36/9-7 *Please refer to footnotes listed below. 1SASD (seismic) values calculated by using a safety factor (Ω) of 2.50 for seismic loads. For SLRFD (seismic), multiply SASD (seismic) by 2.50 and then by a resistance factor (Φ) of 0.65. For SLSD (seismic), multiply SASD (seismic) by 2.50 and then by a resistance factor (Φ) of 0.60. Diaphragm shear stiffness should be calculated separately per Section 1.1.8. 2SASD (wind) values calculated by using a safety factor (Ω) of 2.35 for seismic loads. For SLRFD (wind), multiply SASD (wind) by 2.35 and then by a resistance factor (Φ) of 0.70. For SLSD (wind), multiply SASD (wind) by 2.35 and then by a resistance factor (Φ) of 0.65. Diaphragm shear stiffness should be calculated separately per Section 1.1.8. 3 Tabulated fastening patterns apply to standard (Fy ≥ 33 ksi; Fu ≥ 45 ksi) or high strength (Fy ≥ 80 ksi; Fu ≥ 92 ksi) 1-1/2" deep, 6" center-to-center types B and BI steel deck. Panel buckling has been checked. 4 At diaphragm perimeter, Hilti powder-actuated frame fasteners should be spaced at identical spacing as sidelap connectors. 5 Interpolation of diaphragm shear strength values is allowed between span dimensions, sidelap spacings and deck gauge. Alternatively, use calculations as discussed in Section 1.1.8 to determine diaphragm shear capacities directly. 6 To convert from sidelap spacing (SS) to sidelaps per span (SPS), use the following formula: SPS=((span,ft) x 12)/(SS, in.). Round up to the next whole sidelap connector. 7 For 16 gauge steel deck or for high tensile strength (Fu > 65 ksi) 18 gauge steel deck, use S-SLC 02 M HWH. For more information on Hilti Sidelap Connectors refer to Section 1.5. 8 For diaphragm shear load values using Hilti #10 HWH screws, use the Hilti Profis DF Diaphragm software or contact Hilti at 877-749-6337 or deck@hilti.com. 9 Additional diaphragm fastening patterns and optimized attachment options can be developed from Hilti Profis DF Diaphragm Software. Contact Hilti Technical Services or find more information at www.us.hilti.com/decking (USA) or www.hilti.ca/decking (Canada). 10 For 36/9 or 36/11 patterns, please see footnote 2 of Table 10 (page 19). 60 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 Steel Deck Fastening Systems X-HVB Shear Connector 1.7 1.7.1 Product Description Guide specification The Hilti X-HVB Shear Connector is a mechanically attached shear transfer device for use in composite beam construction with steel beams and concrete slabs as an alternate to welded studs. Shear connector: Shear connectors shall be one piece formed steel with zinc plating in accordance with ASTM B633 SC 1 Type III. Connectors shall be Hilti X-HVB as supplied by Hilti Inc. Product features • Ductile connections • Minimal damage to coatings • Fast and simple installation • Install in virtually any weather • No electrical power source required 1.7.1 Product Description 1.7.2 Material Specifications 1.7.3 Technical Data 1.7.4 Connector Positioning 1.7.5 Ordering Information Installation: Shear connectors shall be installed using Hilti X-ENP-21 HVB powder-actuated fasteners in accordance with manufacturer’s recommendation. (Note: Do not use X-ENP-19 L15.) 1.7.2 Material Specification X-HVB: Carbon Steel with Fu = 39,000 psi Zinc plated for corrosion resistance in accordance with ASTM B633, SC 1, Type III. Reference Section 2.3.3.1 of Hilti North American Product Technical Guide Volume 1: Direct Fastening for more information. 1.7.3 Technical Data Product selection and performance in concrete over metal deck composite floor slabs3 X-HVB connector X-HVB80 X-HVB95 X-HVB110 X-HVB125 X-HVB140 Connector height, Hs in. (mm) Minimum slab thickness, Ycon in. (mm) Maximum rib height, hr in. (mm) wr /hr ≥ 1.8 wr /hr < 1.8 3-1/8 3-11/16 1-3/4 1-3/4 6294 3147 (80) (93) (45) (45) (28.0) (14.0) 3-3/4 4-1/4 2-3/8 2-1/4 (95) (108) (60) (57) 4-5/16 4-13/16 2-15/16 2-5/8 (110) (123) (75) (66) 7868 3934 4-15/16 5-7/16 3-1/8 2-15/16 (35.0) (17.5) (125) (138) (80) (75) 5-1/2 6 3-1/8 3-1/8 (140) (152) (80) (80) Nominal shear strength1, Qn lb (kN) Allowable shear strength2, q lb (kN) 1 Nominal shear strength to be used for designs per AISC-LRFD and unfactored shear resistance per AISC design formulas. 2 Allowable shear strength to be used for designs per AISC-ASD. 3 Tabulated load values based upon installation in base steel greater than or equal to 5/16". Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 61 Steel Deck Fastening Systems 1.7 X-HVB Shear Connector Strength reduction factors for concrete over metal deck composite floor slabs Ribs perpendicular to the beam Ribs parallel to the beam Number of X-HVB's in One Rib Rg 1 1.00 wr 2 0.85 hr ≥3 0.70 wr hr Condition Rg ≥ 1.5 1.00 < 1.5 0.851 1 For a single shear connector. Connector placement along the beams Deflections The ductile performance of the Hilti X-HVB Shear Connector allows distribution of the calculated required number of X-HVB’s uniformly between the points of zero and maximum moment. Beam deflections are computed by conventional elastic formulas. For beams with partial shear connection, deflections may be estimated by using the following formula for the effective moment of inertia: Point loads I eff = l s = n = l tr = Application of large point loads causes abrupt changes in shear. To avoid excessive slip, additional X-HVB connectors may be necessary between the point load and the support. Partial shear connection AISC-LRFD and AISC-ASD both require that the capacity of the installed shear connectors must be no less than 25% of the calculated shear load for full composite design. This requirement is applicable, independent of whether welded studs or X-HVB’s are used for the shear connection. Is + n x ( l t r – ls ) moment of inertia of steel section connection fraction moment of inertia with 100% connection Continuous beams Hilti X-HVB Shear Connectors are also suitable for use in continuous composite beams. The connectors are distributed uniformly between the point of zero moment and the point of maximum moment. To obtain access to Hilti’s BDES Composite Design Software, which designs and analyzes composite and non-composite beams using Hilti X-HVB Shear Connectors under distributed and point loads in accordance with AISC LRFD, contact Hilti Technical Support at 1-877-749-6337. 62 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 Steel Deck Fastening Systems X-HVB Shear Connector 1.7 1.7.4 Connector Positioning Connector positioning (metal decking ribs transverse to beam) 1.One to three X-HVB’s per rib. = = 2.X-HVB’s transverse or parallel to beam. ≥ 1-9/16" 40 ≥ 1-9/16" 40 = Wr ≥1-9/16" Wr ≥1-9/16" 3.With one X-HVB per rib, the leg may be either centered in the rib or positioned to give a 1-9/16" (40 mm) clearance to the side of the rib. ≥ 2" 50 = ≥ 50 2" ≥ 100 4" ≤ 2" 5b. S pacings along the ribs (other decking profiles) ≥ 100 4" Minimum spacing ≥ 2" (50 mm), however for decking profiles with: wr /m < 0.7 and wr /hr < 1.8, the minimum spacing is increased from 2" to 4" (50 to 100 mm). >> 4" 100 51 4.With two or three X-HVB’s per rib, the legs may be either centered in the rib or alternated about the center. m = spacing of ribs 5a. Spacing along the ribs (2" and 3" U.S. composite floor deck profiles) 6.If the decking has a stiffener in the rib bottom, position the X-HVB’s against the stiffener. Connector positioning (ribs parallel to beam and solid slabs) X-HVB’s may be placed with zero clearance to edge of flange. 50 ≥ 2" d Ycon ≤ 4Y or 24" conor 600 4d ≥100 4" 1.7.5 Ordering Information X-HVB Shear Connectors* Description Qty/Pkg X-HVB80 X-HVB95 X-HVB110 X-HVB125 250 250 250 200 Setting Equipment for X-HVB Shear Connectors Description DX-76 X-76-F-HVB Baseplate X-76-P-HVB Piston X-76-PS Stop Ring * X-HVB shear connectors must be fastened with the X-76-F-HVB fastener guide, the X-76-P-HVB piston and the X-ENP-21 HVB fastener. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 63 PTG Decking Supplement 2013 Notes 64 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Direct Fastening Technical Guide 2014 Steel Deck Fastening Systems BAR JOIST FASTENING SYSTEMS DX 860-HSN • Powderactuatedtoolwithahighfasteningratewhichcanhelpsignificantly reducethetimeittakestoattachdeck • Notouch-upworkrequired—perfectforfasteningpaintedorgalvanizeddeck surfaces • Magazinefor40continuousfastenings—upto1000fasteningsperhour • Uniquepiston/brakesystemhelpspreventthefastenerfrompunchingthrough thedeck • Fasteningscanbemadeevenonverythinsupportingstructureswithoutthe needforweldwashers DX 460-SM • Fullyautomatedhand-heldtoolformiscellaneousfasteningsonsteelthicknesses of3/16"andthicker,suchasprofilemetalsheetsonbarjoists. STRUCTURAL STEEL FASTENING SYSTEMS DX 860-ENP-L • Fullyautomatictoolfastensupto1000fasteningsperhour • 40-cartridgeand40-fastenercapacityminimizesloadingtimeandincreases productivity • Built-in,adjustablepowerregulatorforoptimalcontrolinachievingreliable fastenings • Cartridgeandfastenermagazinecanbeloadedfromthetopwithouthavingto bendover • UseOnDemandprogramtomeetyourprojectneeds DX 76 • Powerregulatorforoptimalcontroltoachievereliablefasteningsacrossabroad applicationrange • Magazinefastenersandboostershelpincreaseoperatingspeedandreducethe numberofwastedfasteners • Fastenerguideoptionsallowforcustomizingthetooltothejob DECK SIDELAPS FASTENING SYSTEMS ST 1800 and SDT 5 • SDT5magazineholds50collatedsidelapconnectorsfordecksidelap applicationswhereproductivityisessential • Twohandledesignandlowvibrationgripprovidegreateroperatorcomfortand lessfatigue • Arangeoffastenersforsidelapsandfordecktothinbarjoist • Adjustabletorquecontrolforimprovedsidelapconnectorperformance • Heavydutydesignhelpsensurelongertoollife • RotatablenosepieceofSDT5allowsforeasyaccessintomostdeckprofiles fromavarietyofpositions • Electronicallycontrolled,variablespeedscrewdriverwithclawclutchforeasier fastenerstarts • Quickandeasyjamreleasemechanism Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 Hilti. Outperform. Outlast. P.O.Box21148,Tulsa,OK74121•Hilti,Inc.(US)1-800-879-8000www.us.hilti.com•ServicioalClienteenespañol 1-800-879-5000•Hilti(Canada)Corporation1-800-363-4458www.hilti.ca•Hiltiisanequalopportunityemployer HiltiisaregisteredtrademarkofHilti,Corp.©Copyright2014byHilti,Inc.•H268•3445389•10/14BB Thedatacontainedinthisliteraturewascurrentasofthedateofpublication.Updatesandchangesmaybemadebasedonlatertesting.Ifverificationisneededthatthe dataisstillcurrent,pleasecontacttheHiltiTechnicalSupportSpecialistsat1-800-879-8000.Allpublishedloadvaluescontainedinthisliteraturerepresenttheresults oftestingbyHiltiortestorganizations.Localbasematerialswereused.Becauseofvariationsinmaterials,on-sitetestingisnecessarytodetermineperformanceatany specificsite.Laserbeamsrepresentedbyredlinesinthispublication.PrintedintheUnitedStates *ISO14001USOnly