Kupferle Foundry Product Catalog

Transcription

Kupferle Foundry Product Catalog
April 2011
Water Main Flushing Hydrants
Automatics • Post • Blow‐Off
Water Quality Stations
Bacteriological Sampling Stations
Dedicated Site • Meter Box • Valve Box
Street Washers
1‐800‐231‐3990 • www.hydrants.com • info@hydrants.com The year was 1857 and James Buchanan was President of the United States when John C. Kupferle founded The Kupferle Foundry Company in St Louis, Missouri. For over 150 years, The Kupferle Foundry Company has been making quality products for the waterworks industry ki li d
f h k i d
and continues to be the leader in innovation. Their Eclipse line of products have been an industry standard since the 19th century and along with their MainGuard, g
Truflo, Total Eclipse , Corn King and new Eclipse i‐
Series product lines The Kupferle Foundry Company d
l
h
f l
d
continues to deliver the best in quality and performance with ease of maintenance. Manufacturer of Automatic Flushing ‐ Sampling Stations ‐ Manual Blow‐offs Yard Hydrants ‐ Washdown Hydrants
Table of Contents
Table of Contents
Automatic & Continuous Flushing
Yard Hydrants
Eclipse
• Model #9400 Total Eclipse
• Model #1
• Model #7
• Model #36 Street Washer
• Model #3400 Companion
page 34
page 35
page 36
page 37
Corn King
• Model #903
• Model #909
page 38
page 39
• Model #9400WC
M d l #9400WC
• Model #9700
• Model #9700 Accessories
• Model #9800
• Model #9800WC
Eclipse i‐Series
• Model #9800i
• Model #9700i
Model #9700i
page 4
page 5
5
page 6
page 7
page 8
page 9
page 10
page 11
page
11
NEW
Additional Information
MainGuard
• Model #5100
• Model #5200
• Kupferle Overview
• Kupferle’s Green Initiative
• Water Saving Calculator
• Flushing versus Fire Hydrants
• Flushing Flow Rate Chart
• Novelty Items
• Ordering Info/Quality Assurance
page 12
page 13
Water Quality Stations
Eclipse
• Model #9900
M d l #9900
• Model #9900WC‐2
page 14
14
page 15
NEW
Manual Flushing
Eclipse
• Model #2 Post Hydrant
• Model #85/#85B
• Model #8 Post Hydrant
Model #8 Post Hydrant
• Ratcheting Valve Wrench (RVW)
MainGuard
• Model #77 Blow‐Off
• Model #78 Blow‐Off
• Model #7500 Blow‐Off
• Model #7600 Blow‐Off
page 16
page 17
page 18
page 18
page 26
page 20
page 21
page 22
page 23 Truflo
• Model #TF500
• Model #TF550
• Model #TF800
page 27
page 28
page 29
Water Sampling Stations
Eclipse
• Model #88
• Model #88WC
MainGuard
• Model #94WM
• Model 92 & 92VB
page 30
page 31
page 32
page 33
NEW
inside front cover page 2
page 3
page 24‐25
page 19
page 40
inside back cover
Kupferle’ss Green Initiative
Kupferle
Green Initiative
Automatic Flushing Helps Conserve Our Water Resources
Kupferle’s full line of automatic flushing devices help the environment by conserving water (up to 50% less water usage than manual flushing) when flushing to raise chlorine residual levels and remove disinfectant byproducts (DBPs). Better water for consumers, less water wasted…now that’s a good thing for all of us! Read the Cost‐
Benefit Calculator on the next page and be sure to look for the EnviroGreen™ label on water‐saving Kupferle products to start saving water, time and money!
Kupferle Automatic Flushing Products
Eclipse #9400 Eclipse #9400WC Eclipse #9700 Eclipse #9800 Eclipse #9800WC Eclipse #9800i page 4
page 5
page 6
page 8
page 9
page 10
Eclipse #9400A Eclipse #9400WC‐A Eclipse #9700A Eclipse #9800A Eclipse #9800WC‐A Eclipse #9700i page 4
page 5
page 6
page 8
page 9
page 11
Now EPA Approved!
In 2010, the EPA categorically approved portable and permanent automatic flushing devices (Attachment 2—2010 Clean Water and Drinking Water State Revolving Fund, Part B‐DWSRF 2.2‐11) for GPR funding. Public Water Systems (PWS) can now apply for funding in the form of grants or low‐
g
y
(
)
pp y
g
g
interest and long‐term loans to install automatic flushing devices in order to start saving water, time and money (see water‐saving calculator on the next page)!
Green Project Reserve (GPR) funding is a program designated by the EPA to promote green infrastructure by funding projects and products that provide water and energy efficiency improvements. The EPA requires that a minimum of 20% of the funds made available to each state’s Drinking Water State Revolving Fund (DWSRF) capitalization grants be used by the state for projects
Drinking Water State Revolving Fund (DWSRF) capitalization grants be used by the state for projects to address green infrastructure, water or energy efficiency improvements, or other environmentally innovative activities. For more information, go to www.hydrants.com /envirogreen
2
To download our cost-benefitt calculator that s
shows
dollar saving
gs go to www.hyd
drants.com/enviro
ogreen
Kupferle’ss Green Initiative
Kupferle
Green Initiative
3
A t
Automatic & Continuous Flushing
ti & C ti
Fl hi
Automatic & Continuous Flus
shing
Eclipse #9400
Permanent Automatic Flushing Device for All Climates
The Eclipse #9400 Automatic Flushing Device is designed and
The Eclipse #9400 Automatic Flushing Device is designed and engineered specifically for automatic flushing to the ground in all climates. The permanently installed #9400 provides excellent flow rates of up to 200 gallons per minute to improve and maintain chlorine residual levels and flush disinfectant byproducts (DBPs) to keep water “fresh” and “safe”. The #9400 can be easily installed on a main waterline A one‐inch option is also available with flow rates waterline.
A one inch option is also available with flow rates
up to 65 gallons per minute.
The Eclipse #9400 comes standard with a UV resistant locking cover. Each unit contains a double valve, all brass sampling point, UV resistant ground plate, solenoid valve and self contained digital controller. The #9400 allows for 9 flushing cycles per day at up to four hours of flush time per cycle (for a total max of 24 hours). Operates on a 9‐Volt battery up to one year or 500 flushes! As with all Kupferle products, the Eclipse #9400 is fully serviceable from above ground – no digging!
Standard Features
•3’ Bury
•2” FIP Inlet
•Self Draining, Non‐Freezing
• 2”Automatic Valve, Controller, Battery
•Above‐Grade Flow Adjustment
•UV Resistant Cover and Base
Additional Options
Additional
Options
•Any Depths of Bury Over 3’
•Optional 1” Model #9400‐A •Dechlorination Option
•2” Debris Flushing Pipe
•1” Debris Flushing Pipe 1” Model = Approx. shipping weight 55 lbs. for 3ft. Bury
2” Model = Approx. shipping weight 65 lbs. for 3ft. Bury
4
See Page 2
2” Debris Flushing Pipe
Spec sheets, installation details and additional resources are available at www.hydrants.com/product‐support
A t
Automatic & Continuous Flushing
ti & C ti
Fl hi
Eclipse #9400WC Autom
matic & Continuous Flushing
Permanent Automatic Flushing Device for Warm Climates
The Eclipse #9400WC Automatic Flushing Device is designed The
Eclipse #9400WC Automatic Flushing Device is designed
and engineered specifically for automatic flushing to the ground in warm climates. The permanently installed #9400WC provides excellent flow rates of up to 200 gallons per minute to improve and maintain chlorine residual levels and flush disinfectant byproducts (DBPs) to keep water “fresh” and “safe”. The #9400WC can be easily installed on a main waterline A one‐inch option is also available with a main waterline.
A one inch option is also available with
flow rates up to 65 gallons per minute.
The Eclipse #9400WC comes standard with a UV resistant locking cover. Each unit contains a double‐valve, all brass sampling point, UV resistant ground plate, solenoid valve and self contained digital controller. The #9400WC allows for 9 flushing cycles per day at up to four hours of flush time per cycle (for a total max of 24 hours). Operates on a 9‐Volt battery that last up to one year or 500 flushes! As with all Kupferle products, the Eclipse #9400WC is fully serviceable from above ground – no digging!
Standard Features •1’ Bury
•2” MIP Inlet
•Non‐Draining
•2” Automatic Valve, Controller, Battery
•Above‐Grade Flow Adjustment
•UV Resistant Cover and Base
Additional Options
Additional
Options
•Any depths of Bury over 1’ •Optional 1” Model #9400WC‐A
•Dechlorination Option
1” Model = Approx. shipping weight 55 lbs. for 1 ft. Bury
2” Model = Approx. shipping weight 65 lbs. for 1 ft. Bury
Spec sheets, installation details and additional resources are available at www.hydrants.com/product‐support
See Page 2
5
A t
Automatic & Continuous Flushing
ti & C ti
Fl hi
Automatic & Continuous Flus
shing
Eclipse #9700 Portable Automatic Hydrant Flushing Device
y
Designed and engineered specifically for portable automatic flushing, the #9700 provides excellent flow rates of up to 200 gallons per minute to improve and maintain chlorine residual levels and flush disinfectant byproducts (DBPs) to keep water “fresh” and “safe”. The #9700 can be easily attached to any existing fire hydrant, is portable and can easily be moved between hydrants throughout the system. A one‐inch valve option is also available with flow rates up to 65 gallons per minute.
The Eclipse #9700 comes standard with an aluminum lockable enclosure and a 2 ½” NST swivel outlet connection. Each unit contains a solenoid valve and self contained digital controller. The #9700 allows for 9 flushing cycles per day at up to four hours of flush time per cycle (for a total max of 24 hours).
) Each unit comes with a perforated floor to diffuse p
flushed water. The perforated floor can be removed to redirect flushing water through a hose. Operates on a 9‐Volt battery up to one year or 500 flushes! Collar lock, directional diverter and other optional accessories are available.
y
Standard Features •2‐1/2” NST Inlet
2 Automatic Valve
Automatic Valve
•2”
•Aluminum Lockable Box w/ Key
(powder coated in red or yellow)
•Controller & Battery
Additional Options and Accessories
•Multi‐Directional Diverter •Sampling Point Bibb
•Collar Lock (specify color, red or yellow standard)
•Dechlorination Option
•Meter Stand
•1” Model #9700‐A • Special Threads Available
Non‐Standard colors will be standard enamel paint
(Set‐up charge applies if ’powder coating’ of non‐
standard colors is desired)
standard colors is desired)
1” Model = Approx. shipping weight 15 lbs.
2” Model = Approx. shipping weight 25 lbs.
6
1” Model #9700‐A See Page 2
Easy‐to‐program handheld controller
handheld
controller
Spec sheets, installation details and additional resources are available at www.hydrants.com/product‐support
A t
Automatic & Continuous Flushing
ti & C ti
Fl hi
Eclipse #9700 Accessories Multi‐Directional Diverter
Autom
matic & Continuous Flushing
Accessories that Protect and Offer Solutions for your Flushing Unit
Kupferle Foundry offers several accessories to go with its best‐selling Eclipse #9700 and #9700‐A portable automatic flushing devices. From multi‐
directional diffusers, meter stands, dechlorination option sampling bibbs to
dechlorination option, sampling bibbs to security collar locks, Kupferle provides numerous quality accessories to choose from!
Water Meter Stand
Sampling Bibb
Security Collar Lock
Dechlorination Basket
Serving the Waterworks Industry for over 150 years!
7
A t
Automatic & Continuous Flushing
ti & C ti
Fl hi
Automatic & Continuous Flus
shing
Eclipse #9800 Permanent Automatic Flushing Device for All Climates
Designed and engineered specifically for year‐round
Designed and engineered specifically for year
round permanent automatic flushing, the #9800 provides excellent flow rates of up to 200 gallons per minute to improve and maintain chlorine residual levels and flush disinfectant byproducts (DBPs) to keep water safe. The Eclipse #9800 Automatic Flushing Device is easily installed on a water main and discharges the flushed water directly to a separate
the flushed water directly to a separate underground location, such as a drainage ditch, sanitary or storm sewer. A one‐inch valve option is also available with flow rates up to 65 gallons per minute.
The Eclipse #9800 comes standard with a UV resistant locking cover. Each unit contains a double‐
valve, all brass sampling point, solenoid valve and self contained digital controller. The #9800 allows for 9 flushing cycles per day at up to four hours of flush time per cycle (for a total max of 24 hours). Operates on a 9‐Volt battery for up to one year or 500 flushes! As with all Kupferle products, the Eclipse #9800 is fully serviceable from above p
y
ground – no digging!
See Page 2
Standard Features
•3’ Bury
2 FIP Inlet
FIP Inlet
•2”
•Self Draining, Non‐Freezing
•2”Automatic Valve, Controller, Battery
•Above Grade Flow Adjustment
•UV Resistant Lockable Cover and Key
Additional Options and Accessories
•Any depths of Bury over 3’
• 1” Model #9800‐A
• Dechlorination Option
• 2” Debris Flushing Pipe • 1” Debris Flushing Pipe
•Spare keys #9812 2” Debris Flushing Pipe
1 Model 1”
Model = Approx. shipping weight 55 lbs. for 3ft. Bury
Approx. shipping weight 55 lbs. for 3ft. Bury
2” Model = Approx. shipping weight 65 lbs. for 3ft. Bury
8
Spec sheets, installation details and additional resources are available at www.hydrants.com/product‐support
A t
Automatic & Continuous Flushing
ti & C ti
Fl hi
Eclipse #9800WC Designed and engineered specifically for year
Designed
and engineered specifically for year‐
round permanent automatic flushing, the #9800WC provides excellent flow rates of up to 200 gallons per minute to improve and maintain chlorine residual levels and flush disinfectant byproducts (DBPs) to keep water safe. The Eclipse #9800 Automatic Flushing Device is easily installed on a water main and discharges the
installed on a water main and discharges the flushed water directly to a separate underground location, such as a drainage ditch, sanitary or storm sewer. A one‐inch valve option is also available with flow rates up to 65 gallons per minute.
The Eclipse #9800WC comes standard with a UV resistant locking cover. Each unit contains a double valve, all brass sampling point, solenoid valve and self‐contained digital controller. The #9800WC allows for 9 flushing cycles per day at up to four hours of flush time per cycle (for a total max of 24 hours). Operates on a 9‐Volt battery for up to one year or 500 flushes!
y
p
y
As with all Kupferle products, the Eclipse #9800WC is fully serviceable from above ground – no digging!
See Page 2
Autom
matic & Continuous Flushing
Permanent Automatic Flushing Device for Warm Climates
Standard Features •1’ Bury
•2” MIP Inlet
•Non ‐ Draining •2” Automatic Valve, Controller, Battery
•Above Grade Flow Adjustment
•UV Resistant Lockable Cover and Key
Additional Options and Accessories
•1” Model #9800WC‐A
•Dechlorination Option
•Spare Key, #9812
Approx. shipping weight 65 lbs. for 1 ft. Bury
Spec sheets, installation details and additional resources are available at www.hydrants.com/product‐support
9
A t
Automatic & Continuous Flushing
ti & C ti
Fl hi
Automatic & Continuous Flus
shing
Eclipse i‐Series #9800i
Intelligent Automatic Flushing Device for All Climates
The Eclipse i
The
Eclipse i‐Series
Series model #9800i
model #9800i is one of many new is one of many new
intelligent devices Kupferle is developing to keep water safe for consumers by keeping chlorine residual levels constant and remove disinfectant by‐products (DPBs). The Eclipse i‐
Series #9800i integrates a built‐in chlorine analyzer that measures disinfectant residual levels and directs the valve to flush, if needed, until the desired residuals are attained. It is fully custom programmable allowing the user to set
fully custom programmable allowing the user to set minimum and desired residual levels as well as a maximum flushing times. With the ability to set residual parameters to monitor disinfectant levels, only the precise amount of water is flushed! This not only saves water, but time and money as well!
The Eclipse i‐Series #9800i comes standard with a UV‐
Resistant locking cover. Each unit contains a double‐valve, all brass sampling point and solenoid valve. The Eclipse i‐
Series #9800i operates on 110 supply or solar for power. SCADA/radio compatible. As with all Kupferle products, the Eclipse model #9800i is fully serviceable from above ground – no digging!
S I id F
See Inside Front Cover
C
NEW
Standard Features •2” Inlet
•Built‐in Chlorine Analyzer
•Built‐in Sampling Point
•120 VAC or Solar Powered
•Non‐Draining for Warm Climates
•Locking UV Resistant Cover and Base
•Built‐in Programmable Logic Controller (PLC)
•Automatic Fail‐Safe Solenoid Operated Valve
•Above Grade Flow Adjustment (up to 200 gpm)
Approx. shipping weight 65 lbs.
10
A t
Automatic & Continuous Flushing
ti & C ti
Fl hi
Eclipse i‐Series #9700i
The Eclipse i
The
Eclipse i‐Series
Series model #9700i
model #9700i is one of the many is one of the many
new intelligent devices Kupferle is developing to keep water safe for consumers by keeping chlorine residual levels constant and removing disinfectant byproducts (DBPs). It easily attaches to any fire hydrant (2½” NST) and provides a built‐in chlorine analyzer that measures and records disinfectant residual levels and directs the valve to flush if needed until the desired residuals are
valve to flush, if needed, until the desired residuals are attained. It is fully custom programmable allowing the user to set minimum and desired residual levels as well as an overall maximum flushing times. It’s portability allows users to measure and analyze all of their dead‐
ends and calibrate the programming on existing or new automatic flushing devices to operate at their maximum efficiency.
i
ffi i
Autom
matic & Continuous Flushing
Intelligent Portable Automatic Hydrant Flushing Device
Coming Soon!
Standard Features •2‐1/2” NST Inlet
•Built‐in Chlorine Analyzer
•120 VAC or Battery Powered
•Flow Adjustment (up to 200 gpm)
g
g
( )
•Built‐in Programmable Logic Controller (PLC)
•2” Automatic Fail‐Safe Solenoid Operated Valve
•Aluminum Lockable Box w/Key (red or yellow standard)
Additional Options and Accessories
•Sampling Point Bibb
•Multi‐Directional Diverter •Security Collar Lock (red or yellow standard) Approx. shipping weight TBD
Specification sheets and additional resources are available at www.hydrants.com/product‐support
11
A t
Automatic & Continuous Flushing
ti & C ti
Fl hi
Automatic & Continuous Flus
shing
MainGuard #5100
Permanent Continuous Flusher for Warm Climates (in ground)
The MainGuard #5100 Continuous Flushing Device
The MainGuard #5100 Continuous Flushing Device provides a continuous flow of water on stagnant dead ends! The #5100 is permanently installed on a water main line and provides an adjustable constant flow to keep chlorine residual levels steady and prevent the formation of disinfectant byproducts (DBPs) to keep water safe.
Th M i G d #5100
The MainGuard #5100 comes standard with a 3/8” d d i h 3/8”
male threaded inlet connection, all brass waterway, orifice to control flow of water and provide constant flow, catch basin to discharge water underground ,and a lockable UV protected plastic cover. The standard #5100 maintains a constant flow of .1 to 6 GPM. As with all Kupferle products, the Eclipse #5100 is fully serviceable from above ground – no digging!
Standard Features
•Buries Direct in Ground with no Flange
Water Inlet Enters from Underneath Flusher
Inlet Enters from Underneath Flusher
•Water
•3’ Below Grade Piping Standard
Approx. shipping weight 25 lbs.
12
Spec sheets, installation details and additional resources are available at www.hydrants.com/product‐support
A t
Automatic & Continuous Flushing
ti & C ti
Fl hi
MainGuard #5200
Autom
matic & Continuous Flushing
Portable Continuous Flusher for Warm Climates (bolts to meter box lid)
The MainGuard #5200 Continuous Flushing Device
The MainGuard #5200 Continuous Flushing Device provides a continuous flow of water on stagnant dead ends! The #5200 is temporarily installed by bolting to a meter box lid and provides an adjustable constant flow to keep chlorine residual levels steady and prevent the formation of disinfectant byproducts (DBPs) to keep water safe.
Th M i G d #5200
The MainGuard #5200 comes standard with a 3/8” d d i h 3/8”
male threaded inlet connection, all brass waterway, orifice to control flow of water and provide constant flow, catch basin to discharge water underground and a lockable UV protected plastic cover. The standard #5200 maintains a constant flow of .1 to 6 GPM. As with all Kupferle products, the Eclipse #5200 is fully serviceable from above ground – no digging!
Standard Features •Furnished with Four‐bolt Flange 6” High
•Water Connection enters From Underneath Flusher
•Discharge Pipe Exits HORIZONTALLY through Pedestal
Flange has four 1/2” bolt holes at 5‐9/16” centers
Approx shipping weight 25 lbs.
Spec sheets, installation details and additional resources are available at www.hydrants.com/product‐support
13
W t Q lit St ti
Water Quality Stations
Eclipse #9900 Water Quality Station
Water Qualitty Stations
Permanent All‐In‐One Station for All Climates
The Eclipse model #9900 allows a water system to install a reliable blow‐off today, which can be converted into an automatic flushing device tomorrow. Years after installing the #9900, if water quality issues develop, the automatic flushing feature can be added and water samples can be easily and safely drawn from the #9900 at any time using the prescribed sampling rod. Continuous flushing is also an option.
p g
g
p
Each station comes with a lockable, UV resistant enclosure. As with all Kupferle products, the Eclipse #9900 is fully serviceable from above ground – no digging!
Manual Flushing (2”and 4”)
Sampling Station
Automatic Flushing
Standard Features
•3’ Bury or Less
•4” MJ Inlet
•4” FIP Outlet
• Self Draining, Non‐Freezing
Auto Flushing Flushing “Ready”
Ready
•Auto
•Bac‐T Sampling Point
•Manual Drain On/Off
•Locking Enclosure
Lockable Enclosure
Additional Options and Accessories
•Any Depths of Bury over 3’
•6” MJ Inlet
•1” Automatic Option
•Potable Sampling Rod and Case
•Continuous Flushing Rod
•2” Model #9900 also available
•4” and 2” Risers
•Optional Outlet Sizes
•Dechlorination Option Continuous Flushing
See Page 2
4” Model = Approx. shipping weight 200 lbs. for 3ft. Bury
2” Model = Approx. shipping weight 120 lbs. for 3ft. Bury
14
Spec sheets, installation details and additional resources are available at www.hydrants.com/product‐support
W t Q lit St ti
Water Quality Stations
Eclipse #9900WC‐2 Water Quality Station
Permanent All‐In‐One Station for Warm Climates
See Page 2
Water Qua
ality Stations
The Eclipse model #9900WC
The
Eclipse model #9900WC‐2
2 allows a water system to allows a water system to
install a reliable blow‐off today, which can be converted into an automatic flushing device tomorrow. Years after installing the #9900WC‐2, if water quality issues develop, the automatic flushing feature can be added and water samples can easily and safely be drawn from the #9900WC‐2 at any time using the prescribed sampling rod Continuous flushing is also an option
sampling rod. Continuous flushing is also an option.
Each station comes with a lockable, UV resistant enclosure. As with all Kupferle products, the Eclipse #9900WC‐2 is fully serviceable from above ground – no digging!
Lockable Enclosure
Standard Features
•1’ Bury
•2” FIP Inlet
•2” MIP Outlet
•Non‐Draining
•Auto Flushing Ready
•Bac‐T Sampling Point
•Locking Enclosure with Key
Additional Options and Accessories
Additional
Options and Accessories
•Any Depths of Bury over 1’
•1” Automatic Option
•Potable Sampling Rod and Case
•Continuous Flushing Rod
•2” Riser
•Dechlorination Option 2” Model = Approx. shipping weight 120 lbs. for 1ft. Bury
Spec sheets, installation details and additional resources are available at www.hydrants.com/product‐support
15
M
Manual Flushing
l Fl hi
Eclipse #2 Post Flushing Hydrant
Permanent Flushing Hydrant for all Climates
Man
nual Flushing
The Eclipse #2 Post Hydrant is one of the best selling flushing hydrants for water main dead ends. Designed for performance and durability, the Eclipse #2 provides excellent flow rates for improving chlorine residual levels and flushing byproducts to keep water “fresh”, as well as, scouring for biofilm removal on pipe inner walls.
The Eclipse #2 comes standard with all brass working
The Eclipse #2 comes standard with all brass working parts, nozzle sizes up to 2½” NST, self draining, non‐
freezing, 3’ bury or less, 2‐3/16” valve opening and 1½” pentagon operating nut. Multiple inlets available (see below). As with all Kupferle products, the Eclipse #2 is fully serviceable from above ground – no digging!
* See flushing flow rate chart on page 19
Standard Features
•3’ Bury or Less
Any size nozzle up to 2
size nozzle up to 2‐1/2”
1/2 NST
NST
•Any
•2‐3/16” Valve Opening •Self Draining, Non‐Freezing
•1‐1/2” Pentagon Nut
Additional Options and Accessories
•Any Depths of Bury over 3’
•2” , 2‐1/2” or 3” FIP Inlet
•2”, 3” or 4” MJ Inlet
•Two Nozzles of any size up to 2‐1/2” NST
•Tamper‐Proof Option
•Bolted Flange Top‐Stock
•10” Hand Wheel
•Multiple Wrenches
•Call for Additional Custom Options Eclipse #2A
1¼” 1½”
1¼” or 1½”
also available
Approx. shipping weight 130 lbs. for 3ft. Bury
16
Spec sheets, installation details and additional resources are available at www.hydrants.com/product‐support
M
Manual Flushing
l Fl hi
Eclipse #85 Blow‐Off Hydrant
Permanent Flushing Hydrant for All Climates
The Eclipse #85 Blow‐Off Hydrant is designed and engineered specifically for flushing and provides excellent flow rates . The #85 Eclipse Blow‐Off Hydrant is designed with a heavy wall cast‐iron box. The box sits at ground level and is not traffic rated.
The Eclipse #85 comes standard with all brass and aluminum working parts, numerous outlet sizes 2½” gp
NST or smaller, self draining non‐freezing drain, and numerous inlet sizes also available. As with all Kupferle products, the Eclipse #85 is fully serviceable from above ground – no digging!
Wrench Sold Separately
* See flushing flow rate chart on page 19
Manual Flushing
Standard Features
•3’ Bury or Less
Any Size Nozzle up to 2
Size Nozzle up to 2‐1/2”
1/2 NST
NST
•Any
•2‐3/16” Valve Opening
•Self Draining, Non‐Freezing
•Cast‐Iron Box with Locking Lid
Eclipse #85B
Warm Climate Version
Also Available
Also Available
Additional Options and Accessories
•Any Depths of Bury over 3’
•1‐1/4”, 1‐1/2”, 2”, 2‐1/2”, 3” IP Inlet
•3” or 4” MJ Inlet
•Nozzle Cap
•Long and Short Handle Wrenches Approx. shipping weight 100 lbs. for 3ft. Bury
Spec sheets, installation details and additional resources are available at www.hydrants.com/product‐support
17
M
Manual Flushing
l Fl hi
Eclipse #8 Post Flushing Hydrant
Permanent Flushing Hydrant for all Climates
Man
nual Flushing
The new Eclipse #8 Post Hydrant is designed to deliver performance and durability at flushing water main dead‐ends at a value price. The Eclipse #8 provides excellent flow rates for improving chlorine residual levels and flushing byproducts to keep water safe.
The Eclipse #8 comes standard with all brass working parts, nozzle size up to 2½” NST, self draining, non‐
freezing, 3’ bury or less, 2
freezing, 3
bury or less, 2‐3/16”
3/16 valve opening and valve opening and
1½” pentagon operating nut. Multiple inlets available. As with all Kupferle products, the Eclipse #8 is fully serviceable from above ground – no digging!
COMING SOON!
Standard Features
•3’ Bury or Less
Any size nozzle up to 2
size nozzle up to 2‐1/2”
1/2 NST
NST
•Any
•2‐3/16” Valve Opening •Self Draining, Non‐Freezing
•1‐1/2” Pentagon Nut
Additional Options and Accessories
•Any Depths of Bury over 3’
•2” , 2‐1/2” or 3” FIP Inlet
•2”, 3” or 4” MJ Inlet
•Tamper‐Proof Option
•Bolted Flange Top‐Stock
•10” Hand Wheel
•Multiple Wrenches
•Call for Additional Custom Options Approx. shipping weight 130 lbs. for 3ft. Bury
Approx. shipping weight 130 lbs. for 3ft. Bury
18
Spec sheets, installation details and additional resources are available at www.hydrants.com/product‐support
5,280 feeet = 1 mile
Ideal Scouringg Velocity (5.0 fps))
4” = 195.72 gp
pm
6” = 440.40 gp
pm
8” = 782.90 gp
pm
10” = 1223.30
0 gpm
Manual Flushing
1000 ftt. of pipe equals:
4” = 652.42 gallons
6” = 1,4
468.00 gallons
8” = 2,6
609.70 gallons
10” = 4,078.00 gallons
EPA disin
nfectant guideliness Chlorinee/Chloramines
Minimum
m: 0.5mg/L
Maximum
m: 4.0 mg/L
K f l M
Kupferle Manual Flushing Guidelines
l Fl hi G id li
19
M
Manual Flushing
l Fl hi
MainGuard #77 Post Flushing Hydrant
Man
nual Flushing
Permanent Flushing Hydrant for All Climates
The MainGuard #77 Blow‐Off provides the best in performance and value! Designed and engineered specifically for flushing, the #77 provides excellent flow rates for improving chlorine residual levels and flushing byproducts to keep water “fresh” and “safe”. The unique valve design allows for a full “clear‐
channel” flow (see illustrations) that is superior to other blow‐offs for moving water and passing debris g
p
g
easily. The #77 plunger is also designed to allow for throttling the flow of water while at the same time covering the drain hole to avoid unnecessary erosion.
The MainGuard #77 comes standard with all brass and aluminum working parts, nozzle sizes 2 ½” NST or smaller, traffic break‐away, self draining non‐freezing, 2” FIP vertical (straight) inlet and locking security cover 2
FIP vertical (straight) inlet and locking security cover
standard. As with all Kupferle products, the MainGuard #77 is fully serviceable from above ground – no digging!
* See flushing flow rate chart on page 19
Standard Features
•3’ Bury or Less
•2” FIP Vertical (straight) Inlet
•2‐1/2” NST Nozzle (or any size smaller)
•Self Draining, Non‐Freezing
•All Brass and Aluminum Working Parts
•Traffic Break‐Away
•Locking Security Cover
•Slotted Corp Style Operating Nut
Additional Options and Accessories
•Any Depths of Bury over 3’
•90° Horizontal (side) Inlet
2 MJ Inlet Iron w/ Epoxy Coating
MJ Inlet Iron w/ Epoxy Coating
•2”
•2” MJ Inlet all Brass Valve
•Operating Wrench
Approx. shipping weight 60 lbs. for 3ft. Bury
20
Unique Valve Design Allows for Full
Clear Channel
Channel” Flow and Passing of
Flow and Passing of
“Clear
Large Debris (see flow rates on page 19)
Spec sheets, installation details and additional resources are available at www.hydrants.com/product‐support
M
Manual Flushing
l Fl hi
MainGuard #78 Blow Off Hydrant
Permanent Flushing Hydrant for All Climates
Manual Flush
hing
The MainGuard #78 Blow
The
MainGuard #78 Blow‐Off
Off installs underground in a installs underground in a
standard meter box. Designed and engineered specifically for flushing, the #78 provides excellent flow rates for improving chlorine residual levels and flushing disinfectant byproducts (DBPs) to keep water “fresh” and “safe”. Its unique valve design allows for a full “clear‐channel” flow (see illustrations) that is superior to other blow offs for moving water and passing debris
to other blow‐offs for moving water and passing debris easily. The #78 plunger is also designed to allow for throttling the flow of water while at the same time covering the drain hole to avoid unnecessary erosion.
The MainGuard #78 comes standard with all brass and aluminum working parts, nozzle sizes 2 ½” NST or smaller, traffic break‐away, self draining non‐freezing , 2” FIP vertical (straight) inlet and locking security cover standard. As with all Kupferle products, the MainGuard #78 is fully serviceable from above ground – no digging!
* See flushing flow rate chart on page 19
Standard Features
•3’ Bury or Less
•2” FIP Vertical (straight) Inlet
•2‐1/2” NST Nozzle (or any size smaller)
•All Brass and Aluminum Working Parts
•Self Draining, Non‐Freezing
•Installs Underground in Meter Box
•Locking Security Cover
•Locking Security Cover
•Slotted Corp Style Operating Nut
Unique Valve Design Allows for Full
Clear Channel
Channel” flow and Passing of
flow and Passing of
“Clear
Large Debris (see Flow rates on page 19)
Spec sheets, installation details and additional resources are available at www.hydrants.com/product‐support
Additional Options and Accessories
•Any Depths of Bury over 3’
•90º Horizontal (side) Inlet
•2” MJ Inlet Iron w/ Epoxy Coating
•2” MJ Inlet all Brass Valve
Approx. shipping weight 37 lbs.
21
M
Manual Flushing
l Fl hi
MainGuard #7500 Post Flushing Hydrant
Permanent Flushing Hydrant for All Climates
The Eclipse #7500 Blow‐Off Hydrant is designed and engineered specifically for flushing large amounts of water quickly. The unit provides excellent flow rates for blow‐offs at high velocity. The #7500 Eclipse Blow‐
Off Hydrant accommodates a high flow volume for biofilm scouring applications and its unique valve design allows for flushing of large debris. The unit p
provides ample flushing velocities at half the cost of a p
g
fire hydrant!
Man
nual Flushing
The Eclipse #7500 comes standard with all brass and aluminum working parts, 4” inlet and outlet connections and is self draining, non‐freezing. As with all Kupferle products, the Eclipse #7500 is fully serviceable from above ground –
i bl f
b
d no digging!
di i !
* See flushing flow rate chart on page 19
Standard Features
Standard
Features
•3’ Bury
•4” MJ Inlet
•4” FIP Outlet with Plug
•Self Draining, Non ‐Freezing
Additional Options and Accessories
•Any Depths of Bury over 3’
•6” MJ Inlet
•Locking Cap Feature
Approx. shipping weight 100 lbs. for 3ft. Bury
22
Unique Valve Design Allows for Full
“Clear Channel” Flow and Passing of
Large Debris (see flow rates on page 19)
Large Debris (see flow rates on page 19)
Spec sheets, installation details and additional resources are available at www.hydrants.com/product‐support
M
Manual Flushing
l Fl hi
MainGuard #7600 Blow Off Hydrant
Permanent Flushing Hydrant for All Climates
The Eclipse #7600 Blow‐Off Hydrant installs underground in a meter box and is designed and engineered specifically for flushing large amounts of water quickly and is intended as a replacement of a fire hydrant on a dead‐end water main line. The unit provides comparable flow rates and velocities at half the cost of a fire hydrant. The #7600 Eclipse Blow‐Off Hydrant accommodates a high flow volume for biofilm y
g
scouring applications and its unique valve design allows for flushing of large debris. Manual Flush
hing
The Eclipse #7600 is a below grade unit that fits inside a meter box, comes standard with all brass and aluminum working parts, 4” inlet and outlet connections and is self draining non freezing As with all Kupferle products, draining, non‐freezing.
As with all Kupferle products
the Eclipse #7600 is fully serviceable from above ground – no digging !
* See flushing flow rate chart on page 19
Standard Features
•3’ Bury
•4” MJ Inlet
•4” FIP Outlet with Plug
•Self Draining, Non–Freezing
Additional Options and Accessories
•Any Bury Depths over 3’ •Any Bury Depths over 3
•6”MJ Inlet
•Locking Feature
•Lid for 12” Sewer Pipe
Unique Valve Design Allows for Full
“Clear Channel” Flow and Passing of
Large Debris (see Flow rates on page 19)
Spec sheets, installation details and additional resources are available at www.hydrants.com/product‐support
Approx. shipping weight 90lbs.
23
Man
nual Flushing
Fl hi H d t
Flushing Hydrants versus Fire Hydrants
Fi H d t
Kupferle offers a better solution to placing expensive fire hydrants on waterline dead ends. The Eclipse #7500 and #7600 provides comparable flow rates for flushing and scouring but at half the cost of a fire g
g
hydrant! Fire hydrants provide fire protection for 250 feet on either side of the unit, but when placed on dead ends the downstream area of protection is wasted (see illustration below). Additionally, fire departments prefer NOT to have fire hydrants placed at the end of a cul‐de‐sacs, and residents will enjoy having no above ground installations or parking issues
having no above ground installations or parking issues on their property (Eclipse #7600 below grade fits inside a meter box). The Eclipse #7500 and #7600 are specifically engineered for flushing with a unique valve design that allows larger debris to pass versus a fire hydrant. See the cost benefit calculator on page 25 to see how much you can save using Kupferle’s Eclipse #7500 and h
i K f l ’ E li
#7500 d
#7600 flushing hydrants!
Eclipse #7500
Eclipse #7600
PLAN 1: 1500 foot water main with fire hydrant at dead‐end
PLAN 2: 1250 foot water main with flushing hydrant at dead‐end = $$$ saved
PLAN 2: 1250 foot water main with flushing hydrant at dead‐end = $$$ saved
Flushing Hydrant
250
24
Fl hi H d t
Flushing Hydrants versus Fire Hydrants
Fi H d t
Manual Flush
hing
25
M
Manual Flushing
l Fl hi
Eclipse Ratcheting Valve Wrench (RVW)
Ratcheting Valve Wrench with Swivel Action Socket
The Eclipse RVW is specifically designed to make operating valves easier! With its dual ratcheting feature
operating valves easier! With its dual ratcheting feature and swivel action socket, the Eclipse RVW eliminates the need to turn the operating handle 360º. The Eclipse RVW can be made with a solid or telescoping shaft at various lengths up to 20 feet. The Speedy Valve Wrench (SVW) can be made as a stand alone wrench or as an attachment to the RVW. With its non‐stationary rotating handle for smooth, quick turning the SVW is designed to open valves quickly and easily. NEW
Man
nual Flushing
Independently tested up to 777 ft‐lbs. of torque!
Standard Features ‐ RVW
•3’‐ 6
•3
6’ Solid Shaft Available
Solid Shaft Available
•3’‐6’ Telescoping Shaft Available
•Dual Ratcheting Action
•Ductile Gear and Pawl
•Swivel Action Socket
Additional Options and Accessories
•Custom Lengths Upon Request
• Handle sold separately •Attachable 1¼” Pentagon Key
•Attachable 1½” Pentagon Key
•Attachable 1” Square Key
•Attachable 1½” Square Key
•Attachable 2” Square Key
NEW
Approx shipping weight 10 lbs. for 6 ft. telescoping model
Approx. shipping weight
10 lbs for 6 ft telescoping model
Speedy Valve Speedy
Valve
Wrench (SVW)
Attachable Swivel Handle
26
Attachable Pent and Square Keys
Attachable Auger for Valve Box Clean Out
Spec sheets, installation details and additional resources are available at www.hydrants.com/product‐support
M
Manual Flushing
l Fl hi
Truflo #TF500 Blow Off (fits inside a 5¼” valve box)
Permanent Flushing for All Climates
The Truflo #TF500 Blow
The
Truflo #TF500 Blow‐Off
Off designed and engineered designed and engineered
with a slim profile that fits into a standard 5¼” adjustable valve box. The #TF500 provides an alternative to the home made 2” blow‐off with a two valve box set up. The #TF500 has a unique cast iron, steel, and brass construction. All brass and aluminum construction also available.
Th T fl #TF500
The Truflo #TF500 comes standard with a 2” MIP outlet, d d i h 2” MIP
l
2” FIP vertical straight inlet. Horizontal inlet and low‐
lead options also available. As with all Kupferle products, the Truflo #TF500 is fully serviceable from above ground – no digging!
* See flushing flow rate chart on page 19
See flushing flow rate chart on page 19
Manual Flush
hing
Standard Features
•3’ Bury or Less
2 MIP Outlet
MIP Outlet
•2”
•2” Vertical (straight) Inlet
•9/16” Square Operating Nut
•Cast Iron Headstock
•Fits Inside 5‐1/4” Valve Box
•Self Draining, Non‐Freezing
Additional Options and Accessories
•Any Bury Depths Over 3’
•2” MJ Inlet Iron Adapter
•2” MJ Inlet Brass Adapter
•Horizontal Inlet
•All Brass and Aluminum Construction
•Epoxy Coated Cast‐Iron
•24” Riser
36 Operating Wrench
Operating Wrench
•36”
Approx. shipping weight 35lbs. for 3ft. Bury
Spec sheets, installation details and additional resources are available at www.hydrants.com/product‐support
27
M
Manual Flushing
l Fl hi
Truflo #TF550 Blow‐Off (fits inside a 5¼” valve box)
Permanent Flushing for Warm Climates
Man
nual Flushing
The Truflo #TF550 Blow‐Off designed and engineered for warm climates with a slim profile that fits into a standard 5¼” adjustable valve box. The #TF550 provides an alternative to the home made 2” blow‐off with a two valve box set up. The #TF550 is an all brass design.
The Truflo #TF550 comes standard with a 2” MIP outlet, 2” FIP vertical straight inlet.
outlet, 2
FIP vertical straight inlet. Low
Low‐lead
lead option option
also available. As with all Kupferle products, the Truflo #TF550 is fully serviceable from above ground – no digging!
Standard Features
•2” FIP Inlet
•2” MIP Outlet
•Non‐Draining
•9/16” Square Operating Nut
•All Brass Design
Additional Options and Accessories
•Epoxy Coated Cast‐Iron
•24” Riser •36” Operating Wrench
Approx. shipping weight 15 lbs.
28
Spec sheets, installation details and additional resources are available at www.hydrants.com/product‐support
M
Manual Flushing
l Fl hi
Truflo #TF800 Blow Off Permanent Flushing for Warm Climates
The Truflo #TF800 Blow‐Off
The Truflo #TF800 Blow
Off fits into a standard meter fits into a standard meter
box and provides an alternative to home made 4” blow‐
offs. It features all brass working parts and housing.
The Truflo #TF800 comes standard with a 4” MIP outlet, 4” FIP vertical straight inlet. Low‐lead option also available. As with all Kupferle products, the Truflo #TF800 is fully serviceable from above ground – no di i !
digging!
Manual Flush
hing
Standard Features
•4” FIP Inlet
4 MIP Outlet
MIP Outlet
•4”
•Non –Draining
•All Brass Design
•Operates with Corp. Wrench
Additional Options and Accessories
•Iron Epoxy Coated Body Approx. shipping weight 35lbs. for 3ft. Bury
Spec sheets, installation details and additional resources are available at www.hydrants.com/product‐support
29
S
Sampling Stations
li St ti
Eclipse #88 Sampling Station (bacteriological)
Permanent Sampling Station for All Climates
Sa
ampling Station
ns
The Eclipse #88 Sampling Station is designed specifically for collecting bacteriological samples at a designated point directly from the water main. The #88 provides a 24 hour designated sampling site to retrieve samples at any time versus sampling from homes and businesses. Sampling stations have been shown to lower false positives, speed collection times, and reduce liability concerns.
The Eclipse #88 is a non‐draining unit that comes standard with an all brass waterway and a lockable aluminum box. Unit is manual‐draining, non‐freezing with use of manual hand pump. The option of extreme cold climate protection and low‐lead is also available. As with all Kupferle products, the Eclipse #88 is fully serviceable from above ground – no digging!
is fully serviceable from above ground no digging!
Standard Features
•3’ Bury or Less
•¾” FIP Inlet •Unthreaded Nozzle
•Strong Lockable Aluminum Box
•All Brass Working Parts and Waterway
Freeze Proof (using pump)
(using pump)
•Freeze‐Proof
•100% Serviceable from Above Ground
Additional Options and Accessories
•Any Depths of Bury over 3’
•Threaded Nozzle
•PSI Gauge with Custom Threaded Nozzle
•Brass Exterior Piping
•Pedestal •¼” Ball Valve Versus ¼” Standard Pet‐Cock
•Extreme Cold Climate Package
•Casted Door Logo
•Plastic Enclosure
•Hand Pump •Larger Pump for Extreme Cold Climate
PLEASE CONSIDER EXTREME COLD CLIMATE OPTION FOR DEPTHS OF BURY 5’ AND GREATER Approx. shipping weight 42 lbs. for 3ft. Bury
30
Optional Casted Door Casting
Optional Plastic Cover
Optional Hand Pump
p
g
Optional PSI Gauge and Nozzle Assembly
Optional Pedestal
Spec sheets, installation details and additional resources are available at www.hydrants.com/product‐support
S
Sampling Stations
li St ti
Eclipse #88WC Sampling Station (bacteriological)
Permanent Sampling Station for Warm Climates
The Eclipse #88WC Sampling Station is designed
The Eclipse #88WC Sampling Station is designed specifically for collecting bacteriological samples at a designated point directly from the water main. The #88WC provides a 24 hour designated sampling site to retrieve samples at any time, versus sampling from homes and businesses. Sampling stations have been shown to lower false positives, speed collection times, and reduce liability concerns
and reduce liability concerns.
The Eclipse #88WC is a warm climate unit that comes standard with an all brass waterway and a lockable aluminum box. The option of a durable plastic box and low‐lead is also available. As with all Kupferle products, the Eclipse #88WC is fully serviceable from above ground – no digging!
Optional Plastic Cover
Sa
ampling Station
ns
Optional Casted Door Casting
Standard Features
•1’ Bury All Brass Parts and Waterway
Brass Parts and Waterway
•All
•Strong, Lockable Aluminum Box
•1” Inlet and Flow
•For Warm Climates Only
• Non‐Draining
Additional Options and Accessories
•Any Depths of Bury over 1’
•Pedestal •PSI Gauge
• Casted Door Logo
• Plastic Enclosure
•Customized Units Available
•Stainless, PVC, Low‐Lead Brass also Available
Optional PSI Gauge
Optional Pedestal
Approx. shipping weight 40lbs. for 1ft. Bury
Spec sheets, installation details and additional resources are available at www.hydrants.com/product‐support
31
S
Sampling Stations
li St ti
MainGuard #94WM Sampling Station
Installs into Existing Meter Box
The MainGuard #94WM Sampling Station is designed specifically for collecting bacteriological samples at a designated point directly from the main water line. The #94WM provides a 24 hour designated sampling site to retrieve samples at any time versus sampling from homes and businesses. Sampling stations have been shown to lower false positives, speed collection times, and lower liability concerns.
y
Sa
ampling Station
ns
The MainGuard #94WM is a non‐draining unit that comes standard with an all brass waterway and fits into a standard 5/8” x ¾” existing meter box. Unique threaded valve connects easily and eliminates stress on the meter setter and sampling station components as opposed to quick disconnect models The sampling rod
opposed to quick‐disconnect models. The sampling rod includes a multi‐directional swivel blow‐off head and separate sampling bibb. The option of low‐lead is available.
Standard Features
•Installs in Existing Meter Setting (5/8” x 3/4”)
•Male Valve – No Contamination
•Custom Threaded Valve (no quick disconnect)
Additional Options and Accessories
•All Brass Sampling Rod (variable lengths)
•Carrying Case
•Brass Valve Cover
•Brass Valve Cover
•1” Resetter Model (uses same rod)
•#93WM Converter Kit
Approx. shipping weight 42 lbs.
32
Spec sheets, installation details and additional resources are available at www.hydrants.com/product‐support
W t S
Water Sampling Stations
li St ti
MainGuard #92/#92VB Water Sampling Stations
Permanent Water Sampling Station for All Climates
The MainGuard model #92 sampling station is designed The
MainGuard model #92 sampling station is designed
specifically for collecting bacteriological samples from a designated sampling point at the main water line. The #92 provides a designated sampling point to retrieve samples outside of homes and businesses, therefore, reducing liability on private property and speeding sample collection times. The #92 is easily seen above grade and the #92VB is added to a meter box
grade, and the #92VB is added to a meter box.
Standard Features ‐ #92
•Internal spring loaded female piston type valve
•2‐1/2” Galvanized below ground riser pipe
•2‐1/2” Sch. 80 PVC above ground marker pipe w/ breakaway
•Repairable from above ground
•PVC valve cover
Additional Options and Accessories
•Any Depth of Bury over 3’
•Brass valve cover
•Repair tool
Sa
ampling Station
ns
Approx. weight for 92 is lbs. / Approx. weight for rod is 7 lbs.
Standard Features ‐ #92VB
•Internal spring loaded female piston type valve
•2‐1/2” Galvanized below ground riser pipe
•Repairable from above ground
Additional Options and Accessories
•Any Depth of Bury over 3’
•Brass valve cover
•Repair tool
Specification sheets and additional resources are available at www.hydrants.com/product‐support
Approx. weight for 92 is lbs. / Approx. weight for rod is 7 lbs. 33
Y dH d t
Yard Hydrants
Total Eclipse #1 Yard Hydrant
Permanent Yard Hydrant for All Climates
The Total Eclipse model #1 yard hydrant provides the best in performance and value! Designed and engineered specifically for use in parks, campgrounds, golf courses and homes for non‐drinking use. The #1 has a unique decorative heavy cast iron top stock and four‐pronged turn handle. Tamper proof key operated option available.
The Total Eclipse model #1 comes standard with all
The Total Eclipse model #1 comes standard with all brass working parts, the option of ¾” GHT or 1” MIP hose connection and ¾” or 1” MIP Inlet, self draining non‐freezing drain and key lock options. And, as with all Kupferle products, the Eclipse model #1 is fully serviceable from above ground – no digging!
Yard Hydrrants
Standard Features
•True “dry pipe” design
All brass working parts
brass working parts
•All
•Male IP Inlet
•3’ Bury or less
Additional Options and Accessories
•Any Depths of Bury over 3’
•¾” Vacuum breaker for nozzle
•1” Check valve for nozzle
•1” x 3/4" Brass Reducing Adapter
/
•Key operated
•Galvanized interior operating rod, per foot of Bury
•Galvanized exterior casing pipe, per foot of Bury
•Extra Key
Approx. shipping weight for ¾” 29 lbs.
Approx. shipping weight for 1” 37 lbs. Approx. shipping weight for 1
37 lbs.
34
Specification sheets and additional resources are available at www.hydrants.com/product‐support
Y dH d t
Yard Hydrants
Total Eclipse #7 Yard Hydrant
Permanent Yard Hydrant for All Climates
The Total Eclipse model #7 yard hydrant provides the The
Total Eclipse model #7 yard hydrant provides the
best in performance and value! Designed and engineered specifically for use in parks, campgrounds, golf courses and homes for non‐drinking use. The #7 has a unique decorative heavy cast iron top stock and lift handle. Lock option on handle available.
The Total Eclipse model #7 comes standard with all The
Total Eclipse model #7 comes standard with all
brass working parts, the option of ¾” GHT or 1” MIP hose connection and ¾” or 1” MIP Inlet, self draining non‐freezing drain, handle lock options, and low‐lead option also available. And, as with all Kupferle products, the Eclipse model #7 is fully serviceable from above ground – no digging! Standard Features
•Spring loaded, self closing
•True ‘dry pipe’ design
•All brass working parts
•Male IP Inlet
•3’ Bury or less
Yard Hydrants
Additional Options and Accessories
•Depths of Bury over 3’
•3/4" vacuum breaker for nozzle
1 x 3/4
x 3/4" Brass Reducing Adapter
Brass Reducing Adapter
•1”
•Lockable features
Approx. shipping weight for ¾” 30 lbs. +2 lbs. for every 6”
Approx. shipping weight for 1” 38 lbs. +2 lbs. for every 6”
Specification sheets and additional resources are available at www.hydrants.com/product‐support
35
Y dH d t
Yard Hydrants
Total Eclipse #36 Street Washer
Permanent Box Hydrant for All Climates
The Total Eclipse model #36 Street Washer is designed and engineered for wash down and filling needs. The #36 provides a point to retrieve water to wash down wastewater treatment areas or fill an area with water. The #36 sits flush with the ground saving space in walking areas. The cast iron box and lid is not traffic rated.
The Total Eclipse model #36 comes standard with all brass and aluminum working parts, available nozzle and Inlet sizes are ¾” or 1”, compression type self draining non‐freezing drain, cast iron box and lid. As with all Kupferle products, the Total Eclipse model #36 is fully serviceable from above ground – no digging!
Yard Hydrrants
Standard Features
•3’ Bury or less
Cast iron box
iron box
•Cast
•MIP Inlet
•All brass working parts
•#159 Key
Additional Options and Accessories
•Any Depths of Bury over 3’
•Locking lid
•Brass box & lid
•Deep box
•¾” Vacuum Breaker with deep box
•1” Check Valve
•Galvanized pipe
•#159 Key (spare)
Approx. shipping weight for ¾
Approx.
shipping weight for ¾” 20 lbs. + 2 lbs for every 6
20 lbs. + 2 lbs for every 6”
Approx. shipping weight for 1” 22 lbs + 3 lbs. for every 6”
36
Specification sheets and additional resources are available at www.hydrants.com/product‐support
Y dH d t
Yard Hydrants
Total Eclipse #3400 Yard Hydrant Companion
Permanent Yard Hydrant Companion for All Climates
Kupferle s Yard Hydrant Companion is a pre
Kupferle’s
Yard Hydrant Companion is a pre‐installation
installation sleeve for ¾” Yard Hydrants. Install the Yard Hydrant Companion first, and then slide any ¾” yard hydrant down the sleeve and screw it onto the Yard Hydrant Companion’s internal ¾” nipple. Clamps at the ground line hold the hydrant in place. Then, if your hydrant needs to be replaced it can be done WITHOUT DIGGING! Just undo the clamps unscrew the entire
DIGGING! Just undo the clamps, unscrew the entire hydrant and then either repair and replace or install a new hydrant into the sleeve. Available in any depth of bury.
Standard Features
Additional Options and Accessories
•Depths of Bury over 3’
Specification sheets and additional resources are available at www.hydrants.com/product‐support
Yard Hydrants
Approx. shipping weight 25 lbs. +2 lbs. for every 6”
See our compatible
Yard Hydrants on page
38-39
37
Y dH d t
Yard Hydrants
Corn King #903 Yard Hydrant
Permanent Yard Hydrant for All Climates
The Corn King model #903 Yard hydrant is designed as a “dry and wet” pipe principal of construction. The outer or dry pipe encloses and protects the inside parts while the inner or wet pipe protects water as it passes to the brass outlet nozzle.
The Corn King model #903 comes standard with g
galvanized inside and outside pipe with all brass pp
working parts, ¾” FIP Inlet and ¾” GHT outlet, self draining non‐freezing drain. As with all Kupferle products, the Corn King model #903 is fully serviceable from above ground – no digging!
Yard Hydrrants
Standard Features
•3’ Bury or less
Compression type
type
•Compression
•True ‘dry pipe’ design
•¾” FIP Inlet
•¾” Hose outlet
•Galvanized pipe
Additional Options and Accessories
•Any Depths of Bury over 3’
•¾” Vacuum breaker for nozzle
• Lockable enclosure
#903 shown with optional cast‐aluminum lockable enclosure
Approx. shipping weight 25 lbs + 5 lbs. for every 6”
38
Specification sheets and additional resources are available at www.hydrants.com/product‐support
Y dH d t
Yard Hydrants
Corn King #909 Yard Hydrant
Permanent Yard Hydrant for All Climates
The Corn King model #909 Yard hydrant is designed as a
The Corn King model #909 Yard hydrant is designed as a “dry and wet” pipe principal of construction. The outer or dry pipe encloses and protects the inside parts while the inner or wet pipe protects water as it passes to the brass outlet nozzle.
The Corn King model #909 comes standard with galvanized inside and outside pipe with all brass working
galvanized inside and outside pipe with all brass working parts, ¾” FIP Inlet and ¾” GHT Outlet, self draining non‐
freezing drain. As with all Kupferle products, the Corn King model #909 is fully serviceable from above ground – no digging!
Standard Features
•3’ Bury or less
•Spring–Loaded, Self‐Closing type
•True ‘dry pipe’ design
•¾” FIP Inlet
•¾” Hose outlet
•Galvanized Pipe
Yard Hydrants
Additional Options and Accessories
•Any Depths of Bury over 3’
¾ Vacuum Breaker for Nozzle
Vacuum Breaker for Nozzle
•¾”
•Lockable features
Approx. shipping weight 25 lbs. + 5 lbs for every 6”
Specification sheets and additional resources are available at www.hydrants.com/product‐support
39
N lt It
Novelty Items
Hydrant Lamp
Authentic Brass‐Plated Hydrant Lamp
The Kupferle Foundry Company, maker of hydrants for over 150 years, now offers its 19th century decorative Eclipse #2 post hydrant as a lamp! Made of solid cast‐
iron and then brass‐plated to provide it with a beautiful finish, this unique lamp will become one of your most prized possessions!
NEW
Dimensions: 30
Dimensions:
30” H x 7¾
H x 7¾” W
Weight: 36 lbs.
Only $349.99
Order direct by calling 800‐231‐3990 or faxing an order form to 314‐231‐2820
Order forms can be found at www.hydrants.com/hydrantlamp
h d t
/h d tl
Puppy Dog Hydrant
Authentic Cast‐Iron Hydrant
NEW
The Kupferle Foundry Company, maker of authentic
hydrants for over 150 years, now offers its 19th
century decorative Eclipse #2 post hydrant to dog
owners! This original cast‐iron hydrant comes with a
personalized name plate and chain. Optional urn that fits inside also available, making it a lasting memorial to your faithful friend and companion.
Only $199.99
Dimensions: 23” H x 7¾” W
Weight: 36 lbs.
Order direct by calling 800‐231‐3990 or faxing an order form t 314 231 2820
to 314‐231‐2820
Order forms can be found at www.hydrants.com/puppydoghydrant
40
Od i I f
Ordering Information/Assurance of Quality
i /A
f Q li
Placing Orders by Fax:
314‐231‐2820
For Product Inquiries/Quotes
800‐231‐3990
F P t /C t
For Parts/Customer Service
S i
800‐231‐3990
The Kupferle Foundry
Company proudly sells its
products through waterworks
distributors across the United
States and Canada. To obtain
pricing on Kupferle products,
please contact your local
waterworks distributor(s) or call
1 800 231 3990 for a listing of
1-800-231-3990
distributors in your area.
Spec Sheets, Installation Details, Cut Sheets, Product Info:
www.hydrants.com
h d t
Kupferle is proud to state that its products are made in America! We guarantee our product’s parts and labor for up to one full year under normal installation and operational use. Additionally, Kupferle strives to deliver not only the best in quality products, but also customer service. So if you have an issue with any Kupferle product, please contact us at 1‐800‐231‐3990. In response to the ARRA Compliance of Manufactured Goods as American Made, The Kupferle Foundry Company provides answers to three (3) questions furnished by the USEPA that determines The Kupferle Foundry Company meets the ARRA compliance. To obtain a copy of our compliance document, please go to our website at www.hydrants.com
Kupferle offers low‐lead versions of the following products:
• Eclipse Automatic Flushing Devices (all models)
• Eclipse #88, page 30
• Eclipse #88WC, page 31
• Truflo TF500, page 27
• Truflo TF550, page 28
• Truflo TF800, page 29
• MainGuard #94WM, page 32
Low Lead
2511 North 9th Street, St. Louis, MO 63102
1‐800‐231‐3990 • www.hydrants.com • info@hydrants.com