Reusable Electrodes - makro-med
Transcription
Reusable Electrodes - makro-med
Patented Radiofrequency TECHNOLOGY High Frequency – Low Temperature Surgical Energy Source Dermatology Family Practice General Surgery Gynecology Ophthalmology / Oculoplastics Oral / Maxillofacial Surgery Otorhinolaryngology / Facial Plastics Plastic Reconstructive & Aesthetic Surgery Proctology ® RF ENERGY SOURCES & ACCESSORY PRODUCTS Proven in Hospitals, Universites, Surgi Centers, Ambulatory/Outpatient Clinics and Offices Worldwide. Established in 1955 Radiosurgical Energy Sources 4 Five Distinct Waveforms 4 Surgitron 4.0 MHz Dual RF 5 Surgitron Radiolase I 6 Surgitron Radiolase II 7 Surgitron FFPF EMC 8 ® ® ® ® ® ® 9 Radiosurgical Accessories Neutral Plates 9 Footswitches 10 Cables 11 Adaptors 12 EMC Device Accessories 13 Handpieces 15 Bipolar Forceps 17 Bayonet Bipolar Forceps 19 ACe-Tip 20 Non-Stick Forceps TM RF SurgiPens 22 23 RF Electrodes Sterile/Single-Use Electrodes 24 Empire microIncision 25 ® TM Needles Reusable Electrodes ACe-Tip TM 27 Electrodes Reusable Electrode/ACe-Tip 32 TM Sets Electrode Accessories 33 35 Educational Materials 36 Compact Disks 36 Patient Education Brochures 36 Textbooks 36 Smoke Evacuation System Accessories 37 38 Multi Specialty Accessories 39 Otorhinolaryngology 41 General Surgery/Proctology 48 Gynecology 49 Plastic Surgery 51 Dermatology 53 Radiage /Cosmetic Rejuvenation 54 Ophthalmology/Oculoplastics 56 Family Practice/Podiatry 58 TM 3 RADIOSURGICAL ENERGY SOURCES 5 Distinct Waveforms Surgitron® Dual RF technology has received *IEC3A-S30 IEC-PC (for 110v) power cord IEC-PC (for 220v) power cord worldwide acclaim and • Micro-smooth cutting • Negligible lateral heat • Minimal cellular destruction • Ideal for skin incision recognition from leading and biopsy • Best cosmetic results Shipped complete with: surgeons, clinics, • Fastest healing IEC-PC IEC Power Cord DF-FSC Dual Footswitch & Cable IEC3A-SL1 Instruction Manual Fully Rectified ellman universities and authors. Absorption Comparison of Other Surgical Energy Sources IEC-HP1 IEC Foot-Controlled Handpiece • Cutting with hemostasis • Ideal for subcutaneous IEC-3FHPB IEC 3-Button Fingerswitch Handpiece Surgitron® Dual RF/120 IEC H79 Handpiece Clip • Especially useful in vascular areas while tissue dissection and producing minimal High Frequency — Low Temperature VCD/PC5IEC3 Instructional CD ROM planing. amounts of lateral heat RF Energy Source IEC-BC/I 3- Bipolar Sterile/Single-Use Cables The patented Surgitron® Dual RF energy source represents the most advanced radiowave technology that provides unparalleled surgical control, precision, versatility and safety. The high frequency of the Dual RF minimizes heat dissipation and thus cellular alteration. Clinical benefits include reduced post-operative discomfort, minimal scar tissue formation, maximum readability of histologic specimen, enhanced healing and excellent cosmetic results. IEC-NPC IEC Neutral Plate and tissue damage Partially Rectified The ellman® radiowave energy • Coagulation / Shrinkage • For hemostatic control • Hemostasis with controlled penetration source represents advanced Fulguration ellm radiowave technology that provides unparalleled surgical IEC-3FHPB/D1 Sterile/Single-Use 3-Button Fingerswitch Handpiece DSEP40 40 Medical Electrodes Assortment Package Sterile/Single-Use “J” Series Bipolar Forceps (Item number determined by selection) see page 14 & 15 control, precision, versatility and safety. Clinical benefits • Maximum penetration 4 Patented Surgitron® 4.0 MHz Dual RF/120 IEC ellman’s radiofrequency ellm an 1 2 3 4 5 Fully Filtered ellman RADIOSURGICAL ENERGY SOURCES and hemostasis • Ideal for intentional include reduced post-operative tissue destruction discomfort, minimal scar tissue formation, Bipolar/Wet Field Coagulation enhanced healing and • Pinpoint, micro-coagulation excellent cosmetic results. • No tissue adherence to forceps • No charring or tissue necrosis • Ideal for coagulation in and *(Specify voltage/country specific plug available 110-220V, EU, UA, ANZ) around critical anatomy • Wet field coagulation For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 5 RADIOSURGICAL ENERGY SOURCES RADIOSURGICAL ENERGY SOURCES Surgitron® Radiolase® I Surgitron® Radiolase® II Surgitron® Radiolase® I Radiosurgical High Frequency — Low Temperature 6 Patented Surgitron® Radiolase® I Patented Surgitron® Radiolase® II *Item #RL-S50A *Item #RL2-S50 Shipped complete with: Shipped complete with: IEC-HP1 IEC-HP1 IEC-NPC Foot-Controlled Handpiece Neutral Plate Foot-Controlled Handpiece with Locking Chuck RL-SL1 Operation Manual IEC-NPC Neutral Plate VCD/PC5RRL Video RL2-L1 Operation Manual RL-FSC Footswitch RL2-FSC Dual Footswitch H79 Clip IEC-1FHPA IEC-1FHPA One-Button Fingerswitch Handpiece One-Button Fingerswitch Handpiece IEC-BC/I Bipolar Cable IEC-PC110 (for 110v) Power Cord IEC-PC110 (for 110v) Power Cord IEC-PC220 (for 220v) Power Cord IEC-PC220 (for 220v) Power Cord DSEP40 7 Medical Assortment Package Sterile/Single-Use DSEP40 40 Medical Electrode Assortment Package Sterile/Single-Use “J” Series Bipolar Forceps (Item number determined by selection) see page 14 & 15 Surgitron® Radiolase® II Radiosurgical High Frequency — Low Temperature Surgical Energy Source Surgical Energy Source •Maximize hemorrhage control •Planing of soft tissue unique to radiosurgery •Bacterial free incisions •Pressureless incisions •Reduced operating time There is no further need to debate the virtues of monopolar versus bipolar technology for minor surgery. The ellman® Radiolase® II affords surgeons the ability to utilize both monopolar and bipolar modalities at, the frequency scientifically and clinically proven to produce the least amount of lateral heat and tissue alteration. This technology goes beyond the laser and beyond bipolar in terms of tissue preservation and safety, all at a very affordable price. *(Specify voltage/country specific plug available 110-220V, EU, UA, ANZ) *(Specify voltage/country specific plug available 110-220V, EU, UA, ANZ) For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 7 RADIOSURGICAL ENERGY SOURCES RADIOSURGICAL ACCESSORIES Surgitron® FFPF EMC Neutral Plates Patented Surgitron® FFPF EMC Device Surgitron® FFPF EMC *Item# EMC 110A (for 110v) Power Cord *Item# EMC 220A (for 220v) Power Cord IEC Neutral Plate Shipped complete with: Reusable, coated For Dual RF and Radiolase® Devices (1 pc) HP1 Foot-Controlled Handpiece with Locking Chuck H4 EMC Neutral Plate *PC DSEP40 EMC Power Cord 40 Medical Electrode Assortment Package Sterile/Single-Use EMCL1 Operating Manual H79 Handpiece Clip H66 Electrode Protector Stand DVD/EMC1 Instructional Video IEC-NPC With the ellman ® Reusable Neutral Plate, no skin contact required. IEC Disposable Neutral Plate Standard Size IEC-NPD Single-Use For Dual RF and Radiolase® Devices (25 pcs) High Frequency — Low Temperature Surgical Energy Source The ellman® Sterile/Single-Use • Minimal Tissue Alteration • No Burning or Charring of the Tissue • Bacteria-Free Incisions • Reduced Surgical Time • Improved Visibility of Operative Field • Maximized Hemorrhage Control • Pinpoint Coagulation Neutral Plate is a sensing, pre-gelled, self-adhering, dispersive pad. The effective IEC Disposable Neutral Plate Small Size IEC-NPD-S electrodes are two aluminum Single-Use For Dual RF and Radiolase® Devices (25 pcs) oil conductors, covered by a hydrogel conductive adhesive. The conductive hydrogel provides a low-current density return path from the patient to the RF Device while the two EMC Neutral Plate foils provide a means of sens- H4 ing contact quality. Reusable, coated For the EMC Device (1 pc) *(Specify voltage/country specific plug available 110-220V, EU, UA, ANZ) 8 For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 9 RADIOSURGICAL ACCESSORIES RADIOSURGICAL ACCESSORIES Footswitches Cables Bipolar Cable IEC-JX/B Dual Frequency Footswitch and Cable DF-FSC Reusable For use with Surgitron® Dual RF or Radiolase® II Devices (1 pc) For Surgitron® Dual RF Device (1 pc) IEC-BC Sterile/Single-Use Minor Surgery Bipolar cable For use with Surgitron® Dual RF or Radiolase® Devices (5 pcs) Single-Action Bipolar Footswitch and Cable DF-FSC/3 JX/E For Surgitron® Dual RF Device (1 pc) Reusable For use with EMC Device (1 pc) Quick-Connect™ Cable Radiolase Footswitch and Cable RL-FSC For Surgitron® Radiolase® I Device (1 pc) For use with SurgiPen™ Suction Tonsil and Suction Adenoid Probes, Disposable Suction Coagulator, Mono Stan RF Forceps, Rodin™ Micro Surgery handpiece, Micro Fibre® Electrode. IEC-SP020 Reusable For use with Surgitron® Dual RF or Radiolase ® II Device (1 pc) SP020 Dual Monopolar/Bipolar Footswitch RL2-FSC Reusable For use with EMC Device (1 pc) For Surgitron® Radiolase® II Device (1 pc) Snare Cable For use with Polyp Snare™ IEC-H7B Reusable For use with Surgitron® Dual RF or Radiolase® II Device (1 pc) H7B Pneumatic Footswitch SVFSC For use with Surg-e-Vac™ Smoke Evacuation System (1 pc) Reusable For use with EMC Device (1 pc) Lap/Endo Monopolar Cable IEC-UC Reusable For use with Surgitron® Dual RF or Radiolase® II Device (1 pc) Monopolar cable for Endoscopic instruments 10 For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 11 RADIOSURGICAL ACCESSORIES RADIOSURGICAL ACCESSORIES Adaptors Adapters for Surgitron® EMC Field Battery Adaptor Kit FK101 Includes: Adaptor, Inverter and Cables The Field Battery Adaptor is designed to operate with the ellman® line of radiosurgical Universal Fingerswitch Adapter EMC-KA Reusable For use with EMC Device, handpiece not included (1 pc) The ellman® Universal Fingerswitch Adapter plugs into the side of your devices only. The purpose is Surgitron® FFPF EMC. to allow the operation of the The adaptor eliminates the radiosurgical device with a “disappearing” foot pedal. 12-volt automotive The standard foot-controled battery when there is no handpiece is still primary AC power available. operational. Fingerswitch Handpiece XKO6C Surg-e-Doc Reusable For use with EMC Universal Fingerswitch Adapter (2 pcs) SDS30 The Surg-e-Doc offers the surgeon the ability to utilize an extra monoplar port thereby having two handpieces available at the surgical site. This reduces the need to frequently change electrodes in a single handpiece. EMC Universal Fingerswitch Plug The Surg-e-Doc also provides for automatic activation/deactivation of the ellman® Surg-e-Vac™ smoke evacuation system thereby eliminating the need for an additional footpedal in the surgical/treatment room. 12 For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 13 RADIOSURGICAL ACCESSORIES RADIOSURGICAL ACCESSORIES For Surgitron® EMC Handpieces Steri Caps™ enable you to EMC Steri Caps™ EMC-H35 Reusable Steri CapTM (3 for large dial and 3 for small dial) for use with EMC only, 3-Blue and 3-Black (6 pcs) control in total sterility with Magnified view autoclavable protective dial covers. 3-Button Fingerswitch Handpiece with Locking Chuck IEC-X3FHPB Reusable Accepts 1/16" and 3/32” Shaft Electrodes (2 pcs) For Surgitron® Dual RF The ellman® handpiece is ergonomicaly designed to fit comfortably in your hand therefore maximizing productivity by reducing Sterile 3-Button Fingerswitch Handpiece with Locking Chuck Bipolar Converter™ EMC-H95A For use with EMC Device (1 pc) The Bipolar ConverterTM IEC-3FHPB/D operator fatigue and provides the surgeon the Sterile/Single-Use Accepts 1/16" and 3/32” Shaft Electrodes, (10 pcs) For Surgitron® Dual RF discomfort. convenience of switching the ellman® Surgitron® EMC from the Handpiece / Antenna Plate monopolar mode to the Bipolar 3-Button Fingerswitch Blade Handpiece with Locking Chuck IEC-XBHP3 Forceps mode with the simple Bipolar Converter Steri Caps™ H96 Caps for activation switch for use with Bipolar Converter™ (3 pcs) flick of a switch. This eliminates the need to plug and unplug the cords during surgery. The Wall Bracket space saving accessory attaches easily to any vertical surface. Wall Bracket Reusable Accepts Sterile/Single-Use Blades (assorted surgical blades including #10, and #15) and 1/16" Electrode (2 pcs) For Surgitron® Dual RF Sterile 3-Button Fingerswitch Blade Handpiece with Locking Chuck IEC-BHP3/D Sterile/Single-Use Accepts Sterile/Single-Use Blades and 1/16” Electrodes, (10 pcs) For Surgitron® Dual RF The ellman® Wall Bracket will HH Wall Bracket with hardware. For use with EMC only Swivel arm and swivel plate.r (1 pc) support up to 40 lbs. and is ideal for the Surgitron® EMC. 2-Button Fingerswitch Handpiece with Locking Chuck XKO6C Reusable Accepts 1/16" and 3/32” Shaft Electrodes (2 pcs) For Surgitron® EMC Device 14 For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 15 RADIOSURGICAL ACCESSORIES RADIOSURGICAL ACCESSORIES Handpieces Bipolar Forceps ellman® Bipolar Forceps provides clean wet-field One-Button Fingerswitch Handpiece coagulation. IEC-1FHPA Reusable Accepts 1/16" and 3/32" shaft electrodes (2 pcs) One button fingerswitch handpiece for Radiolase® Devices J1 Length 9.5cm, 0.4mm, Straight Tip J1B Length 9.5cm, 0.4mm, Bent Tip J2 Length 9.5cm, 0.3mm, Curved Flat/Angled Tip microInsulated Needle Handpiece with Locking Chuck IEC-XH136 – For Surgitron® 4.0 Dual RF and Radiolase® II Devices (2 pcs) XH136 – For Surgitron® EMC Device (2 pcs) Reusable. Smaller orifice for insertion of ellman ® microInsulated needles only. Included in Cosmetic Treatment package (1 pc) Recent forceps modification of Blade Handpiece with Locking Chuck IEC-H15 – For Surgitron® Dual RF and Radiolase® Devices, accepts 1/16” Shaft H15 – For Surgitron® EMC Device, accepts 1/16” Shaft IEC-QH15 – Accepts 3/32” Shaft. For Surgitron® Dual RF QH15 – Accepts 3/32” Shaft. For Surgitron® EMC Surgitron ® EMC (Monopolar) the ellman® radiosurgical bipolar accessories developed some years ago, now make J3 Length 7.8cm, 0.4mm, Angled Tip Reusable. Foot Pedal activation (2 pcs) For use with assorted surgical blades including #10, and #15 simultaneous cutting and coagulation extremely easy. With the added safety of low wattage, there is no collateral Foot-Controlled Handpiece with Locking Chuck IEC-XHP1 – For Surgitron® Dual RF and Radiolase® Devices XHP1 – For Surgitron® EMC Device Surgitron ® Dual RF and Radiolase ® (Monopolar) J4 Length 7.8cm, 0.3mm, Straight Tip visualization is greatly Reusable. Accepts 1/16" and 3/32" shaft (2 pcs) improved. Furthermore, there Separate plugs are used in is no possibility of unintended accordance with the corresponding device, the thermal damage and direct J5 Length 9.2cm, 0.3mm, Bent Tip J8 Length 16.3cm, 1.0mm, Straight Tip or offsite burns. Rodin™ Microsurgery Handpiece 16 XRHP – Length (3.895”) 98.93mm, Width (.460”) 11.68mm Surgitron® Dual RF, Radiolase ® Reusable. To be used with IEC Quick-Connect™Cable For Surgitron® Dual RF and Radiolase® Devices, accepts 1/16” Shaft (2 pcs) (See page 11z for Quick-Connect™ Cable, Cat. No. IEC-SP020) (See page 32 for Rodin™ Microsurgery ACe-Tip™ Electrode Set, Cat. No. RACE7) RODIN™1 Rodin™ RF Microsurgery Set One RHP Rodin™ Microsurgery Handpiece, one IEC-SP020 Quick-Connect™ Cable, one RACE7 Rodin™ Microsurgery ACe-Tip™ Set, and instructions for use. and the Surgitron® EMC. For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 17 RADIOSURGICAL ACCESSORIES RADIOSURGICAL ACCESSORIES Bipolar Forceps Bayonet Bipolar Forceps J9 Length 16.2cm, 1.0mm, Straight Tip J7 Length 17.3cm, Tip Wide 1.0mm, Bayonet, Flat Tip J7U Length 17.3cm, Tip Wide 1.0mm, Bayonet, 45° Up, Flat Tip J7D Length 17.3cm, Tip Wide 1.0mm, Bayonet, 45° Down Flat Tip EMC Bipolar Cord (see page 8) J10 Length 16.2cm, 2.0mm, Straight Tip ellman® Bayonet Bipolar J13 Length 15.6cm, Tip Wide 1.0mm, Bayonet, non-stick epistaxis, Serrated Tip Forceps enhance access to the surgical environment J11 Length 12.2cm, 0.4mm, Straight Tip for increased visibility during all radiosurgical Surgitron ® Dual RF and Radiolase ® Bipolar Cord J12 J14 J19 18 Length 10.9cm, 1.0mm, Straight Tip J17 Length 17.9cm, Tip Wide 1.0mm, Bayonet, external tip insulated J18 Length 16.9cm, Tip Wide 0.5mm, Bayonet J20 Length 16.6cm, Tip Wide 2.0mm, Bayonet J21 Length 19.7cm, Tip Wide 1.0mm, Bayonet procedures. (see page 8) Length 10.8cm, 0.7mm, Straight Tip Length 13.6cm, 2.0mm, Straight Tip For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 19 RADIOSURGICAL ACCESSORIES RADIOSURGICAL ACCESSORIES ACe-Tip Non-Stick Forceps ACe-Tip Non-Stick Forceps TM TM Featuring Advanced Composition Alloy “Non-Stick”, Low Temperature Featuring Advanced Composition Alloy “Non-Stick”, Low Temperature ACe-Tip™ Technology Advantages: • Non-Adherent • Improved Surgical Outcomes ACBF-010 Length (3.5”), 8.89cm, 0.5mm, Straight ACBF-015 Length (7.0”), 17.18cm, 0.7mm, Straight ACBF-016 Length (7.0”), 17.18cm, 1.2mm, Straight ACBF-017 Length (7.0”), 17.18cm, 1.5mm, Straight • Minimal Absorption Magnified view Magnified view • Tissue Preservation ACBF-011 Length (3.5”), 8.89cm, 0.5mm, Bent Magnified view Magnified view Adherence Free ACBF-012 Length (4.5”), 11.43cm, 0.5mm, Straight Magnified view Magnified view ACBF-013 Length (5.5”), 14.00cm, 0.5mm, Straight Magnified view ACBF-014 Magnified view ACBF-021 Length (6.5”), 16.51cm, 1.0mm, Bayonet, Serated Tip Magnified view ACBF-022 Length (7.25”), 18.52cm, 1.0mm, Bayonet Length (6.25”), 15.88cm, 1.0mm, Straight Magnified view 20 ACe-Tip™ Non-Stick Bipolar Forceps clinical photos For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 21 RADIOSURGICAL ACCESSORIES RF ELECTRODES RF SurgiPen™ Electrodes (3/32”) 2.4mm SP010 # 4 Curette, 4mm Sterile/Single-Use, (15 pcs) SP011 # 7 Curette, 7mm Sterile/Single-Use, (15 pcs) (1/16”) 1.6mm The Patented RF SurgiPen™ can be energized with high radiofrequency waveforms, Proximal shaft diameter is Proximal Shaft Diameter available in 3/32" or 1/16" (2.4mm or 1.6mm) to Fine - Used when minimal tissue alteration is desired accommodate standard Regular - Used to produce more coagulation handpiece connection. or used as a standard instrument. SP012 Ball Sterile/Single-Use, (15 pcs) Most surgical specialties will benefit from the use of this line of unique SP013 Loop Sterile/Single-Use, (15 pcs) instruments due to their ABOUT ellman® Electrodes: All ellman® electrodes are frequency-matched to the ellman® energy source for minimal tissue alteration. The insulated shaft of most electrodes can be bent or contoured for all surgical procedures. precision and versatility. SP014 Needle Sterile/Single-Use, (15 pcs) SurgiPen’s™ ergonomic handle design is composed INFORMATION Regarding Ordering Electrodes: of lightweight material for SP015 # 15 Scalpel Sterile/Single-Use, (15 pcs) fatigue-free manipulation. Code To Electrode Suffixes: B- Bendable D- Disposable (Sterile/Single-Use) Code To Electrode Prefixes: T- Package of (2 pcs) X- Package of (5 pcs) SP016 Round Blade Sterile/Single-Use, (15 pcs) SP017 Vari-Tip™ Sterile/Single-Use, (15 pcs) Most electrodes are available in 1/16” or 3/32” shaft sizes. Use “Q” as a prefix when ordering 3/32” shaft size, i.e. QTA8B Longer electrode shaft sizes are available. Contact ellman’s sales representatives for more details. Quick-Connect™ Cable IEC-SP020 RF SurgiPen™ to be used with the Quick-Connect™ Cable. See page 11 for more information. 22 For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 23 RF ELECTRODES RF ELECTRODES Sterile/Single-Use Empire® microlncision™ Needles The ellman® Empire® microIncision™ Needle Empire microlncision™ Needle Electrodes Medical Electrode Set ellman® Sterile/Single-Use DSEP40 RF electrodes are the latest Sterile/Single-Use Assortment of 8 styles, Sterile/Single-Use RF electrodes, available in 1/16” Shaft Only (40 pcs) Includes 5 of each electrode: A2D, A8D, B1D, B2D, C3D, D8D, E3D, F1D advance in Radiosurgery. They are regarded as the safest cutting electrodes One Style Sterile/Single-Use Electrodes available by doctors Available in 1/16” Shaft Only (25 pcs per pack) A2D A3D/OS A8D Vari-Tip™ Wire Electrode Adjustable cutting wire B2D Round Loop Electrode 1/4” Dia. Round Loop Electrode 3/8” Dia. C3D Diamond Loop Electrode 3/16” Dia. D8D Ball Electrode 2.3 mm E3D Scalpel Electrode 1” Length E4D Scalpel Electrode 1/2” Length TEE301 Length 2cm, straight TEE302 Length 3cm, straight TEE303 Length 4cm, straight High Frequency Radiowave energy to accomplish cell-specific interaction and produce optimum results, while reducing post-operative scarring and promoting TEE304 90° angle faster healing. The ellman® Sterile/Single-Use TEE305 45° angle Empire® microIncision™ RF electrode eliminates the risk of cross contamination as well as ensuring patient confidence. B1D Magnified view for all Empire microlncision™ worldwide. Fine Wire Electrode 3/8” Length Needle Electrode 3/4” Length Electrodes deliver focused Sterile/Single-Use, available in 1/16” or 3/32” (2 per pack) Use “Q” as a prefix when ordering 3/32” shaft size Needle Electrodes are used for TEE306 Length 3cm, 3mm 45° angle TEE307 Length 2cm, 3mm 45° curved precise cutting and coagulation during radiosurgical procedures. Proximal shaft diameter is available in 3/32" or 1/16" TEE308 1cm needle, Length (4”), 10.10cm, straight sleeve TEE309 1cm needle, Length (5”), 12.70cm, straight sleeve (2.4mm or 1.6mm) to accommodate standard handpiece connection. TEE310 1cm needle, Length (6”), 15.24cm, straight sleeve Empire® microIncision™ TEE311 1cm needle, Length (7”), 17.78cm, straight sleeve in individual sterile packages Needle Electrodes are supplied of two, are Single-Use and F1D TEE312 1cm needle, Length (4”), 3mm 45° angle, straight sleeve should not be re-sterilized. Broad Needle Electrode TEE313 1cm needle, Length (5”), 3mm 45° angle, straight sleeve TEE314 1cm needle, Length (6”), 3mm 45° angle, straight sleeve TEE315 1cm needle, Length (7”), 3mm 45° angle, straight sleeve 24 For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 25 RF ELECTRODES RF ELECTRODES Empire® microlncision™ Needles Reusable Electrodes Empire microlncision™ Needle Electrodes Needle Electrodes are Needle Electrodes* Sterile/Single-Use, available in 1/16” or 3/32” (2 per pack) Use “Q” as a prefix when ordering 3/32” shaft size Magnified view for all Empire microlncision™ Reusable 1/16” shaft size or 3/32” (2 pcs) Use “Q” as a prefix when ordering 3/32” shaft size TEE316 2cm needle, Length (4”), 10.16cm, 45° angle, straight sleeve TEE317 2cm needle, Length (5”), 12.70cm, 45° angle, straight sleeve TEE318 2cm needle, Length (6”), 15.24cm, 45° angle, straight sleeve primarily used for incisions and excisions in precise TA1B Length 3/8", Super Fine Wire TA2B Length 3/8", Fine Wire TA9B Length 3/8", Regular Wire TA3B Length 3/8", Regular Needle TF1B TEE319 2cm needle, Length (7”), 17.78cm, 45° angle, straight sleeve TA8B TEE320 1cm needle, ,Length (4”), 10.16cm, curved sleeve Length 1/2”, Broad Needle Vari-Tip™ Microdisection™ Needle (comes with additional wire and has an adjustable depth) surgical procedures. Choice of Wire Gauge Fine - Used when minimal tissue alteration is desired Regular - Used to produce more coagulation TEE321 1cm needle, Length (5”), 12.70cm, curved sleeve Round Loop Electrodes Round Loop Electrodes* TEE322 1cm needle, Length (6”), 15.24cm, curved sleeve Reusable 1/16” shaft size or 3/32” (2 pcs) Use “Q” as a prefix when ordering 3/32” shaft size TEE323 1cm needle, Length (7”), 17.78cm, curved sleeve shaving lesions, contouring TBBB TEE324 Bayonet 5/32" Dia. Round Loop, Fine Wire 1/4" Dia. Round Loop, Fine Wire 1/4" Dia. Round Loop, Regular Wire TEE325 1cm needle, Length (2”), 5.08cm, curved sleeve TB9B TB10B 19/64" Dia. Round Loop, Fine Wire 19/64" Dia. Round Loop, Regular Wire TEE326 1cm needle, Length (1”), 2.54cm, curved sleeve TB2B TB5B 3/8" Dia. Round Loop, Fine Wire 3/8" Dia. Round Loop, Regular Wire TEE327 1cm needle, Length (3/4”), 1.91cm, straight TB3B TB6B 1/2" Dia. Round Loop, Fine Wire 1/2" Dia. Round Loop, Regular Wire For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com tissue and are excellent for obtaining biopsy specimens. TB1B TB4B TEE328 1cm needle, Length (1”), 2.54cm, curved sleeve 26 are primarily used for *Electrodes are displayed in actual size. For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 27 RF ELECTRODES RF ELECTRODES Reusable Electrodes Reusable Electrodes Diamond Loop Electrodes* Reusable 1/16” shaft size or 3/32” (2 pcs) Use “Q” as a prefix when ordering 3/32” shaft size Diamond Loop Electrodes Ball Electrodes* are primarily used for Reusable 1/16” shaft size or 3/32” (2 pcs) Use “Q” as a prefix when ordering 3/32” shaft size one-stroke elliptical incisions. TC1B TC4B 1/8" Diamond Loop, Fine Wire 1/8" Diamond Loop, Regular Wire TC3B TC6B 3/16" Diamond Loop, Fine Wire 3/16" Diamond Loop, Regular Wire TC17B TC18B 1/4" Diamond Loop, Fine Wire 1/4" Diamond Loop, Regular Wire TC19B TC20B 5/16" Diamond Loop, Fine Wire 5/16" Diamond Loop, Regular Wire TC21B TC22B 7/16" Diamond Loop, Fine Wire 7/16" Diamond Loop, Regular Wire Reusable 1/16” shaft size or 3/32” (2 pcs) Use “Q” as a prefix when ordering 3/32” shaft size used for coagulation. They seal superficial blood TD3B vessels reducing post2mm Ball operative discomfort. Triangle Loop Electrodes Triangle Loop Electrodes* Ball Electrodes are primarily are primarily used for TD8B 2.36mm Ball TD9B 3.17mm Ball TD10B 4.34mm Ball TD11B 4.75mm Ball Oval Loop Electrodes* Oval Loop Electrodes are Reusable 1/16” shaft size or 3/32” (2 pcs) Use “Q” as a prefix when ordering 3/32” shaft size primarily used for shaving lesions and contouring TP1B TP2B 5/32" Oval Loop, Fine Wire 5/32" Oval Loop, Regular Wire TP3B TP4B 1/4" Oval Loop, Fine Wire 1/4" Oval Loop, Regular Wire TP5B TP6B 19/64" Oval Loop, Fine Wire 19/64" Oval Loop, Regular Wire TP7B TP8B 3/8" Oval Loop, Fine Wire 3/8" Oval Loop, Regular Wire TP9B TP10B 1/2" Oval Loop, Fine Wire 1/2" Oval Loop, Regular Wire tissue. shaving lesions and TC9B TC10B 5/32" Triangle Loop, Fine Wire 5/32" Triangle Loop, Regular Wire TC7B TC8B 1/4" Triangle Loop, Fine Wire 1/4" Triangle Loop, Regular Wire TC11B TC12B 19/64" Triangle Loop, Fine Wire 19/64" Triangle Loop, Regular Wire TC13B TC14B 3/8" Triangle Loop, Fine Wire 3/8" Triangle Loop, Regular Wire TC15B TC16B 1/2" Triangle Loop, Fine Wire 1/2" Triangle Loop, Regular Wire contouring tissue. *Electrodes are displayed in actual size. 28 For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 29 RF ELECTRODES RF ELECTRODES Reusable Electrodes Reusable Electrodes Scalpel Electrode*s Scalpel Electrodes are used Javate Endoscopic DCR Electrodes* The patented Javate Reusable 1/16” shaft size or 3/32” (2 pcs) Use “Q” as a prefix when ordering 3/32” shaft size primarily for incisions and exci- R6 Javate Endoscopic DCR Set of 7 Assorted Electrodes Endoscopic DCR electrode sion of tissue. The blade shape TE1B 3/16” Scalpel, 45° Angle R7S 7mm Short Exposure Electrode (1 pc) provides broader coagulation R7L 7mm Long Exposure than a needle electrode. TE2B eliminates cutaneous scars and cosmetic blemishes while shortening Electrode (1 pc) 3/8” Scalpel post-operative recovery R9S 9mm Short Exposure TE3B 1” Scalpel Empire® MicroTip Needles are Electrode (1 pc) tapered and have a pinpoint Empire® MicroTip Electrodes* design which produces Reusable 2mm exposed tip (2 pcs, one of each) micro-smooth cutting and time and pain. R9L 9mm Long Exposure Electrode (1 pc) R11S 11mm Short Exposure Electrode (1 pc) coagulation while creating R11L 11mm Long Exposure TEE227 Empire MicroTip Needles one .010 wire, one .020 wire Insulated Coated Needle Set Electrode (1 pc) the least amount of tissue alteration. R12 9/64” Round Loop Exposure Electrode (1 pc) *Electrodes are displayed in actual size. Insulated Needle Electrodes Insulated Needle Electrodes™* D7 Insulated Coated Needle Set (3 pcs) D6A Fine Insulated Coated Needle .004 Super Fine, White, (1 pc) D6B Fine Insulated Coated Needle .007 Fine, Purple, (1 pc) D6C Fine Insulated Coated Needle .009 Regular, Orange, (1 pc) Reusable, 1/2mm exposed tip are used for the treatment of Telangiectasia and for epilation. Radiosurgical Mucotome Electrodes* H140 Radiosurgical Mucotome Electrode Set of 1/16” Shaft Reusable Set of 3 electrodes, includes H141, H142 & H143 Used for excision of mucosal strip H141 Insulated Mucotome Electrode 8mm wide x 2mm depth (1 pc) H142 Insulated Mucotome Electrode 10mm wide x 2mm depth (1 pc) H143 H144 Insulated Mucotome Electrode 12mm widex x2mm 2mmdia. depth (1 pc) 4mm wide H145 6mm wide x 2mm dia. Rhinophyma Electrode Set EE234 Set of 3 Reusable EE233 19/64” Triangle Loop, (1 pc) EE232 1/8” Triangle Loop, (1 pc) EE231 1/2” Triangle Loop, (1 pc) *Electrodes are displayed in actual size. 30 For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com *Electrodes are displayed in actual size. For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 31 RF ELECTRODES RF ELECTRODES Reusable Electrodes* ACe-Tip™ Advanced Composition Alloy–Low Temperture Reusable Electrodes Sets Rodin™ Microsurgery ACe-Tip™ Electrode Set RACE7 TNAEE286 HLTZ Tonsilotomy Set of 3 ACe-Tips electrodes TM The ellman® ACe-Tip™electrodes Includes one each of: TNAEE284, TNAEE285, TNAEE287 are designed to reduce resistance/impedance which in TNAEE284 HLTZ Tonsillotomy, ACe-Tip , TM 15mm Loop, .010 wire, 1/16” shaft (2 pcs) Reusable 1.5” shaft length, 1/16” dia., Bendable Assortment (7 pcs) Includes one each of: REE305, RA2B, RA8B, RD3B, RBBB, RC3B, RB1B turn will reduce thermal damage. The interface between these TNAEE285 HLTZ Tonsillotomy, ACe-Tip , TM electrodes and the tissue is biologically stable. TNAEE287 1cm Needle, 3” Curved Sleeve ACe-Tip , 1/16” shaft (2 pcs) TM TNAA9B 3/8” Length ACe-Tip Regular Wire 1/16” shaft (2 pcs) Standard Electrode Set S10B Reusable 1/16” shaft size or 3/32” Use “Q” as a prefix when ordering 3/32” shaft size Assortment (7 pcs) Includes one each of: C7B, B1B, C3B, A3B, D8B, F1B, A8B ellman 12mm Loop, .010 wire, 1/16” shaft (2 pcs) TM TNAD3B 2mm Coagulating Ball ACe-Tip 1/16” shaft (2 pcs) TM TNATB3B 3mm Tapered Ball ACe-Tip 1/16” shaft (2 pcs) TM 5mm Tapered Ball ACe-Tip 1/16” shaft (2 pcs) ellman TNAD13B TM TNAB1B 1/4” Round Loop ACe-Tip Fine Wire 1/16” shaft (2 pcs) Assorted Needle Electrode Set 1/4” Round Loop ACe-Tip Regular Wire 1/16” shaft (2 pcs) Includes one each of: A1, A2, A9, A3, F1 (5 pcs) TM TNAB4B XA TM TNAB2B 3/8” Round Loop ACe-Tip Fine Wire 1/16” shaft (2 pcs) TM TNAB5B 3/8” Round Loop ACe-Tip Regular Wire 1/16” shaft (2 pcs) TM TNAA8B Vari-Tip™ ACe-Tip™ 1/16” shaft (2 pcs) Assorted Round Loop Electrode Set XB TNAEE305 Empire microlncision™ Needle ACe-Tip™1/16” shaft (2 pcs) *Electrodes are displayed in actual size. ● Conductivity–Advanced composition alloy RF electrode has a high conductivity which is a departure from the traditional alloy electrode ● Lower Temperature– Advanced composition alloy RF electrode makes it possible to cut tissue at 38°C. Separation of tissue is due to the intracellular resonance which causes the explosion of the cells at body temperature instead of burning and charring of the cells ● Adherance Free– Non-sticking of tissue and blood to the RF advanced composition electrode ● Reduced Post-Op Pain–Reduced swelling and bruising 32 For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com Fine Wire Includes one each of: B3, B2, B9, B1, BB XBRB Regular Wire Includes one each of: B6, B5, B10, B4, BB (5 pcs) For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 33 RF ELECTRODES RF ELECTRODES Reusable Electrodes Sets Electrodes Accessories Assorted Diamond Loop Electrode Set Fine Wire Includes one each of: C21, C19, C17, C3, C1 XCRB Regular Wire Includes one each of: C22, C20, C18, C6, C4 (5 pcs) ellm an XCFB Electrode Protector Stand™ H66 Electrode Protector Stand™ For regular 2” standard electrodes Holds 12 electrodes, 6 1/16” x 6 3/32” (1 pc) H66A XD Includes one each of: D11, D10, D9, D8, D3 (5 pcs) ellm Assorted Ball Electrode Set Electrode Protector Stand™ For large 4" long electrodes Holds 12 electrodes, 6 1/16” x 6 3/32” (1 pc) The ellman® Electrode Protector Stand™ protects your electrodes from damage and breakage during the sterilization process. The ellman® Electrode Protector Stand™ will stand on any flat surface for easy identification and access to each electrode. Assorted Oval Loop Electrode Set XPFB Fine Wire Includes one each of: P9, P7, P5, P3, P1 XPRB Regular Wire Includes one each of: P10, P8, P6, P4, P2 (5 pcs) Electrode Block™ H1 Electrode Block™ Holds 18, 1/16" Electrodes (1 pc) H1A Electrode Block™ Holds 9, 1/16" Electrodes and 9, 3/32" Electrodes (1 pc) QH1 Assorted Triangle Loops Electrode Set XTFB Electrode Block™ Holds 18, 3/32" Electrodes (1 pc) Fine Wire Includes one each of: C15, C13, C11, C9, C7 XTRB Regular Wire Includes one each of: C16, C14, C12, C10, C8 (5 pcs) 34 For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 35 EDUCATIONAL MATERIALS SMOKE EVACUATION SYSTEM Educational Accessories Device/Accessories Compact Disks Oculoplastic Techniques by Jay Justin Older, MD VCD/OP31 2 Disk Set At ellman® we are committed ellman® brings you the to the ongoing education of strongest smoke suction the doctors as well as their system, the Surg-e-Vac™, patients. with a capture of 150 feet per minute at the inlet wand Patented Patient Education Brochures tip. The unique compact Surg-e-Vac™ SV110 SV220 Surg-e-VacTM (for 110v countries) Surg-e-VacTM (for 220v countries) multi-filtration technology has been designed to trap macro and micro airborne Cosmetic Eye Surgery LIT/OP1A Facial Veins LIT/DE1 Radiage™ Skin Tightening LIT/DE2 (50 pcs) (50 pcs) Facial Lesions LIT/CO1 Treatment of Snoring LIT/ENT1 (50 pcs) (50 pcs) SurgiCart™ particles and offer a H156 “breathe-free” environment SurgiCartTM III with extended base, instrument tray with gooseneck arm, adjustable height, hospital locking wheels, rolls easily from room to room for you, your staff and your patients. (50 pcs) Textbooks 36 Minor Surgery H202A Procedures for Primary Care A Text & Atlas 4th Edition, by John Stuart Brown 2nd Edition H208 by Drs. John L. Pfenninger and Grant C. Fowler Eyelid Tumors H207 by Jay Justin Older, MD Oculoplastic Surgery with Radiofrequency H205/BL The Surg-e-Vac™ Smoke Evacuation System has been designed with a high suction, high flow rate centrifugal action pump. The ultra-quiet motor is used to draw the surgical smoke from the surgical site through the vacuum tubing and into the Quad Filter™ where the surgical smoke is processed by a series of filters. Vac Assist Stand VV133 by Drs. G. Aimino, G. Davi, and M. Santella For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 37 SMOKE EVACUATION SYSTEM MULTI-SPECIALTY ACCESSORIES Accessories Accessories Surg-e-Vac™ Accessories Iso-Dent™ Kit Iso-Dent™ is a purified isobutyl The accessories below are used only for Surg-e-Vac™ EID142A cyanoacrylate formulated to Isobutyl Cyanoacrylate Tissue Adhesive, four 2cc Vials, 100 Squeez-etts™, 10 Super Squeez-etts™, 1 Super Dish™ Pneumatic Footswitch TM Surg-e-Vac Quadtration Filter SVF1 (3 pcs) SVXF1 (12 pcs) SVFSC provide major advantages in the treatment of superficial (10-1/2 Ft. Cable) (1 pc) wounds. Iso-Dent™ is a liquid monomer For both Surg-e-Vac™ and Vapor-Vac II™ Accessories which, upon contact with Speculum Tubing Reducing Package VV130 includes (2 pcs) VV128 (2 pcs) VV129 Plastic Hose VV148 Reusable 7/8” diameter (1 pc) VV140 Speculum Tubing Reducer Fitting (10 pcs) VV129 Saf-T-Wand External Tub VV128 VF121 1/4" Autoclavable (2 pcs) (3 pcs) EID143 blood and body fluids, rapidly Isobutyl Cyanoacrylate™ Tissue Adhesive, four 2cc Vials, 100 Squeez-etts™, 10 Super Squeez-etts™, 1 Super Dish™ The blue color allows you to see where you placed the Iso-Dent™ polymerizes to form a strong, thin, flexible tissue bridge and protective barrier to foreign matter. Super Dish™ (2 pcs) Speculum Tubing Blue Iso-Dent™ Kit ESD230 Squeez-etts™ provide safe, Medicament Tray and Squeez-etts™ Stand (4 pcs) controlled, pinpoint application of Iso-Dent™. Squeez-etts™ ESQ127 Vapor-Vac II™ Accessories Liquid Dispenser (100 pcs) These accessories below are used only for Vapor-Vac II™ Charcoal Filter External Filter Saf-T-Wand Filter Set VC123 VF124 VV146 (2 pcs) (10 pcs) (25 pcs) Super Squeez-etts™ Disposable External Filter Vapor-Vac™ Wand Clip VV139 VV131 (25 pcs) (1 pc) H54 (50 pcs) H54B (200 pcs) H54 38 For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com H54B For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 39 MULTI-SPECIALTY ACCESSORIES MULTI-SPECIALTY ACCESSORIES Accessories Otorhinolaryngology Medi-Frig™ Medi-Frig™ is a portable, Portable Cryosurgery Skin Refrigerant hand-held, cryosurgical 3” Length Handpiece with Locking Chuck spray unit containing IEC-XLP1 H11B 1 280g. can, 10 Straw Applicators tetrafluoroethane (-54°C). XH11B 6 cans, 60 Straw Applicators The ellman® cryosurgical spray is safe, storable, easily trans- H11BCS 25 cans, 250 Straw Applicators portable and cost-effective compared to traditional liquid Wipe-Its™ Reusable For Surgitron® 4.0 Dual RF and Radiolase® II Devices 3” Length, Accepts 1/16" and 3/32" shaft, procedures for Laparoscopy and Micro-Larynx (2 pcs) XLP1 Reusable For the EMC Device 3” Length, Accepts 1/16" and 3/32" shaft, for Laparoscopy and Micro-Larynx procedures (2 pcs) The Patented Micro-Larynx™ Probe allows quick and nitrogen. An added advantage efficient coagulation, automatic is that it is nonflammable and limiting of penetration depth can be used in conjunction and reduced perforation risk with radiosurgical, Micro-Larynx™ RF Probes with minimized risk of injuries electrosurgical and laser IEC-EE275A to larynx structures. procedures. Reusable For Surgitron® 4.0 Dual RF and Radiolase® II Devices 1/16" shaft, 240mm long, (3 pcs) The Micro-Larynx™ Probe can be used for Granulomas, Papillomatosis, Cyst Biopsies, Wipe-Its™ are easy to use, Vocal Cord Polyps, Posterior H19 Pressure sensitive sandpaper pads used to clean radiosurgical electrode tips (4 pcs) for effortless removal of tissue Cordectomy, Glottic and from radiosurgery tips. Sub-glottic Angiomas, Magnified view Magnified view Magnified view Loop Needle Ball EE276 EE277 EE278A 1/16" shaft, 240mm long (1 pc) 1/16" shaft, 240mm long (1 pc) 1/16" shaft, 240mm long (1 pc) Laryngeal Tumor and Laryngeal Biopsies. Micro Fibre® Electrode XMF-A Magnified view Sterile/Single-Use Monopolar Wire 600mm Length (1mm O.D.) for endoscopic procedures, Attaches to Quick-Connect™ Cable (3 pcs) Quick-Connect™ Cable Reusable Proximal cable for Micro Fibre® System. See page 8 for ordering information 40 For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 41 MULTI-SPECIALTY ACCESSORIES MULTI-SPECIALTY ACCESSORIES Otorhinolaryngology Otorhinolaryngology Clear-Vu™ Electrodes have been designed to enhance OTO-RAM™ Radiofrequency Assisted Myringotomy Set Clear-Vu™ Bayonet Electrodes IEC-EE600 Sterile/Single-Use, (13cm Long Shaft), (1 pc) 1/16” shaft size, 3/32” shaft size available, order with a “Q” prefix Reusable Two 4” tubes, 1.5mm and 2.0mm and one Myringotomy Handpiece CV-B1 Bayonet 1mm Ball Reusable RF Assisted Myringotomy Handpiece (1 pc) 2mm hole OTO-RAM™ Probes EE601 2mm hole 50 microns alteration Tympanic membrane alteration zone during the procedure. The Clear-Vu™ electrodes are manufactured with CV-S Bayonet Spatula proprietary surgical grade material for maximum performance and integrity. CV-L5 Bayonet 5mm Loop The assorted tip CV-L7 Bayonet 7mm Loop configurations allows for CV-D Bayonet Diamond 11cm precise surgical treatment. CV-W Bayonet Fine Wire 11cm Reusable 2.0mm Orifice (1 pc) Reusable Insulated 1cm and exposed 1cm (2 pcs) maintaining a ‘clear view’ CV-N Bayonet microIncision™ Needle CV-L3 Bayonet 3mm Loop EE602 TEE230 CV-B2 Bayonet 2mm Ball CV-B3 Bayonet 3mm Ball Reusable 1.5mm Orifice (1 pc) Patented RF Myringotomy Electrode™ environment for precise tissue interaction while IEC-H604 The OTO-RAM™allows for an effective, safe treatment where office or clinical procedures take place in only a few minutes. Costs for OR Surgery and extensive use of antibiotics and general anesthesia are greatly reduced. The OTO-RAM™is cost effective compared to laser assisted myringotomy. access to the surgical Bayonet RF Turbinate Volume Reduction Electrode™ OTO-Ram Probe Tip Reusable Bipolar Turbinate Probe and cord (1 pc) Tips Insulated 1cm and Exposed 1cm IEC-I6D The Bayonet Turbinate For Surgitron® 4.0 Dual RF and Radiolase® II Devices I6/JXE For EMC Device Electrode and Bipolar Handpiece design includes a OTO-Guide for RF Micro Fibre® pencil grip for easy handling OTO1 with a bayonet needle for easy intranasal visualization during surgery. Ear Speculum for RF Micro Fibre® ESPEC Magnified view 42 For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 43 MULTI-SPECIALTY ACCESSORIES MULTI-SPECIALTY ACCESSORIES Otorhinolaryngology Otorhinolaryngology RAUP Electrode™ H81A1 Sterile/Single-Use RAUP Radiosurgically Assisted Uvulopalatoplasty (2 pcs) Patented RF Suction Adenoid Probes IEC-H85 Reusable Set of 3 Probes, Quick-Connect™ Cable, and Cleaning Brush IEC-H86 Small Probe 9mm with Quick-Connect™ Cable, (1 pc) Sub-Mucosal VTR (UPP) Electrode TEE229A Sterile/Single-Use For volumetric reduction of redundant tissue (2 pcs) IEC-H87 Medium Probe 15mm with Quick-Connect™ Cable, (1 pc) IEC-H88 Large Probe 19mm with Quick-Connect™ Cable, (1 pc) Tongue Base Reduction Electrode™ TEE605 Sterile/Single-Use, For volumetric reduction of redundant tissue (2 pcs) Cleaning Brush for Suction Probe H89 (3 pcs) Patented Suction Tonsillectomy Probe™ and Quick-Connect™ Cable IEC-H83/SP Adenoid RF Electrode™ TEE228 Reusable For Surgitron® 4.0 Dual RF and Radiolase® II Devices H83/SP For EMC Device Reusable 1/4” Triangle, 4” Length, Teflon Insulated (2 pcs) HLTZ Tonsillotomy Electrode™ TEE284 Reusable .010 Wire, 15mm Loop (2 pcs) Patented RF Bipolar Tonsil Reduction Probe™ and Quick-Connect™ Cable IEC-H84 Reusable For Surgitron® 4.0 Dual RF and Radiolase® II Devices H84 For EMC Device 44 For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 45 MULTI-SPECIALTY ACCESSORIES MULTI-SPECIALTY ACCESSORIES Otorhinolaryngology Otorhinolaryngology Patented RF Suction Coagulator™ RF Assisted Tonsillotomy (RAT) Ball Electrodes™ HD41 EE264 Set of 3 Reusable TEE261 2.0mm Ball 4" long (2 pcs) Sterile/Single-Use For use with Quick-Connect™ Cable, (12 pcs) (see page 8 for Quick-Connect™ Cable) Magnified view Magnified view Patented RF Angled Suction Coagulator™ TEE262 2.36mm Ball 4" long (2 pcs) HD42 Sterile/Single-Use For use with Quick-Connect™ Cable, (12 pcs) (see page 8 for Quick-Connect™Cable) The Ball Tonsil Probe is an important advancement over Magnified view the traditional tonsillotomy. TEE263 3.17mm Ball 4" long (2 pcs) Magnified view The RAT procedure permits controlled reduction up to 80% Magnified view of the tonsil without excessive Patented Suction Coagulation Kit Cryptolysis Electrode Reusable TE1022B IEC-H40 Reusable (2 pcs) Shipped with three 3” and three 6” tubes For Surgitron® 4.0 Dual RF and Radiolase® II Devices H40 Shipped with three 3” and three 6” tubes For EMC Device also includes 1/16”, 3/32” and 1/8” Caliber sizes Stylus Round Wire thermal damage or blood loss. An RF cryptolysis probe comprises a generally elongated insulated structure leading to a distal end that is angled downward and terminates in a narrow tip that is exposed. The exposed tip is inserted into tonsillar crypts that may contain bacteria, and activated to clean out any debris, then to sterilize the canal and seal the surface without thermal damage to surrounding tissue. Polyp Snare™ System for Nasal Polyps Cryptolysis IEC-H301 Reusable H44 Suction Tube 6” Long, 1/16” Orifice For Surgitron® 4.0 Dual RF and Radiolase® II Devices with Snare Cable and 3 wires H45 Suction Tube 6" Long, 3/32" Orifice H301 For EMC Device with Snare Cable and 3 wires H46 Suction Tube 6" Long, 1/8" Orifice H47 Suction Tube 3-3/4" Long, 1/16" Orifice H48 Suction Tube 3-3/4" Long, 3/32" Orifice H49 46 Suction Tube 3-3/4" Long, 1/8" Orifice For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com H7A Snare Wires 6 wires H7B Snare Cable For EMC Device (1 pc) IEC-H7B Snare Cable For Surgitron® 4.0 Dual RF and Radiolase® II Devices (1 pc) For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 47 MULTI-SPECIALTY ACCESSORIES MULTI-SPECIALTY ACCESSORIES General Surgery/Proctology Gynecology Patented RF Laparoscopic Handpiece Radiosurgery Touch Technique IEC-XLP1 Reusable LLETZ Electrodes Assortment Set The ellman® LLETZ loop W4 W4D electrodes are used for the One of each in 5 styles, reusable (5 pcs) One of each in 5 styles, Sterile/Single-Use (5 pcs) diagnosis and treatment of Laparoscopy Handpiece, 3” Length accepts 1/16” and 3/32” shafts For Surgitron® 4.0 Dual RF and Radiolase® II Devices (1 pc) LLETZ Individual Electrodes Available in 1/16” or 3/32” Use “Q” as a prefix when ordering 3/32” shaft size Use “D” as a suffix when ordering Sterile/Single-Use Versions of the LLETZ loop electrodes. cervical intraepithelial neoplasia (CIN) and dysplasia. Patented RF Laparoscopic Electrodes™ Endometriosis L7 Reusable Lap-Trode Assortment, 37.5mm Length Electrodes (5 pcs) Reusable Lap-Trode Individual Electrodes, 37.5mm Length Electrodes, 1/16” Shaft W1 W1D 15mm x 10mm Loop, reusable (1 pc) 15mm x 10mm Loop, Sterile/Single-Use (5 pcs) W2 W2D 20mm x 10mm Loop, reusable (1 pc) 20mm x 10mm Loop, Sterile/Single-Use (5 pcs) W3 W3D 25mm x 10mm Loop, reusable (1 pc) 25mm x 10mm Loop, Sterile/Single-Use (5 pcs) F2 F2D Endo-Cervical Box 8mm x 11mm Box, reusable (1 pc) Endo-Cervical Box 8mm x 11mm Box, Sterile/Single-Use (5 pcs) W18 W18D 5mm Ball, reusable (1 pc) 5mm Ball, Sterile/Single-Use (5 pcs) L3 2mm Ball Lap-Trode Myomectomy Magnified view L4 9.5mm Needle Lap-Trode Magnified view L5 2.3mm Hook Lap-Trode Luna Conization Electrode™ Reusable G1 G1/4 Magnified view L6 2.3mm Blade Lap-Trode Conization Electrode 4" long, Rotated at 360° to provide a cone shaped specimen Standard Electrode Set S10B/4 4” shaft length, (7pcs) see page 28 for more information Magnified view L8 Hook Needle Lap-Trode External Genital Lesion RF Electrodes™ Reusable W15 Complete Set of Genital Lesion Electrode set of 4, includes W16, W17, W18 and W19 Electrodes Gupta RF Gun (Pravin Gupta Procto-Gun) W16 90mm Length, Angled Box IEC-FSGUN W17 4mm Length, Box W18 90mm Length, 5mm Ball W19 90mm Length, 3/8" Needle Magnified view Reusable Accepts 1/16" and 3/32” Shaft Electrodes (1 pc) For Surgitron® 4.0 Dual 48 RF Fingerswitch Gun Handle For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 49 MULTI-SPECIALTY ACCESSORIES MULTI-SPECIALTY ACCESSORIES Gynecology Plastic Surgery LLETZ Bayonet Electrodes W35 LLETZ Bayonet Electrode Set (5 pcs) Reusable. Use “D” as a suffix when ordering Sterile/Single-Use W35D Sterile/Single-Use (5 pcs) Javate/Khan RF Endoscopic Forehead Suction Probe™ Reusable W32 Reusable Bayonet, 25mm Loop (1 pc) W32D Sterile/Single-Use (5 pcs) W31 Reusable Bayonet, 20mm Loop (1 pc) W31D Sterile/Single-Use (5 pcs) W30 Reusable W30D W34 W34D W33 W33D The Javate/Khan Endoscopic Bayonet, 15mm Loop (1 pc) Sterile/Single-Use (5 pcs) Reusable Bayonette, 5mm Ball (1 pc) Sterile/Single-Use (5 pcs) Reusable Endo-Cervical Bayonet, 8mm Box (1 pc) Sterile/Single-Use (5 pcs) Javate/Khan Endo Forehead Suction Set IEC-EE260 Reusable Includes 2 probes, one Spade, one Scalpel with Suction Handpiece and Cable for Surgitron® 4.0 Dual RF and Radiolase® II Devices EE260 For EMC Device Forehead Suction Probe™ utilizes a unique combination of suction and radiofrequency cutting. It Improves operating efficiency and significantly enhances results while Vaginal Speculums H55 Vaginal Speculum - Large, 5” Length H57 Vaginal Speculum - Standard, 4 1/2” Length H58 Vaginal Speculum (2 pcs - Large and Standard) Javate/Khan Coated Flat Scalpel EE257 Reusable 7/16” Tip Diameter (1 pc) providing ample access and visualization to the surgical site. The Javate/Khan Endoscopic Forehead Suction Stylus Probe™ enables precise and controlled muscle resection Vaginal Lateral Wall Retractor H69 Magnified view with profound hemostasis, eliminates coronal scar and Monsel’s Solution Javate/Khan Coated Spade H90 EE258 Reusable 500 ml (Ferric Subsulfate) Post-Operative Medicament eliminates potential hair loss. 7/16” Tip Diameter (1 pc) Needle Extender/Measured Dose Syringe H71 Magnified view 50 For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 51 MULTI-SPECIALTY ACCESSORIES MULTI-SPECIALTY ACCESSORIES Plastic Surgery Dermatology Patented Dr. Constantin Stan Monopolar Forceps The ellman® Micro, Mini and Mono Stan Forceps simultaneously dissect and Micro Stan RF Forceps™ IEC-MJ21 coagulate with little For treating telangiectasia and epilation of hair follicles H135A For EMC Device IEC-H135A For Surgitron® 4.0 Dual RF and Radiolase® II Devices Package Includes: Reuseable. One MicroInsulated Needle Handpiece One package of 50 MicroInsulated Sterile Needles and One package of 50 Patient Education Brochures Reusable Suggested for Blepharoplasty and Facelift procedures 3.5” Length Includes Quick-Connect™ Cable and Video CD For use with Surgitron® 4.0 Dual RF Device bleeding. Using the 4.0 the Stan Forceps results in Reuseable MJ21 dramatically shorter IEC-XH136 For EMC Device recovery time as well as MHz radiofrequency with reducing the risk of complications such as The ellman® Cosmetic Cosmetic Treatment Package XH136 Reuseable H137 H1375 LIT/DE1 you to add more revenue to your practice this year by using ellman® radiofrequency!! This is an effective comfortable MicroInsulated Needle HandpieceTM For EMC Device (2 pcs) MicroInsulated Needle Handpiece For Surgitron® 4.0 Dual Devices (2 pcs) Treatment Package will allow way to remove small unsightly TM “spider veins” with minimal recovery time, minimal or no MicroInsulated Sterile Needles (50 pcs) MicroInsulated Sterile Needles – bulk pkg (250 pcs) Patient Education Brochure: FAQ’s – Facial Veins (50 pcs) scarring and immediate improvement in appearance. infection, bleeding and Magnified view post-operative pain. Mini Mono Stan RF Forceps™ Dermatology Electrode Assortment Set Until recently, there were IEC-MJ11/M DDERM40 only surgical means for Reusable Monopolar Forceps with Cutting, Coagulation, Irrigation, Suction Port Suggested for Face Lifts 4.875” Length Includes Quick-Connect™ Cable and Video CD For use with Surgitron® 4.0 Dual RF Device Assorted, Sterile/Single-Use Electrodes, 1/16” shaft (4 electrode styles) eliminating larger veins. D8D (15 pcs) With the advent of ellman® B1D (5 pcs) radiowave sclerotherapy, most veins can now be MJ11/M F1D (15 pcs) For EMC Device completely and permanently A8D (5 pcs) eliminated without surgery or injections. Magnified view Mono Stan RF Forceps™ IEC-MJ11 Reusable Monopolar Forceps with Cutting, Coagulation, Irrigation, Suction Port Suggested for Breast Augmentation Procedures 6.125” Length Includes Quick-Connect™ Cable and Video CD For use with Surgitron® 4.0 Dual RF Device Mono and Mono Stan Forceps are serrated to provide better hemostasis. Insulated Sclerotherapy Needles™ D41 D42 D43 27 Gauge, 1" Needle 30 Gauge, 1/2" Needle Insulated Sclerotherapy Needle Set, 27-Gauge and 30-Gauge (2 pcs, one of each) For EMC Device Rhinophyma Electrode Set see page 30 Corneal Shields™ see page 57 Chedly Eyelid Retractor see page 57 For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com MJ11 52 The insides of tips on the Mini 53 MULTI-SPECIALTY ACCESSORIES MULTI-SPECIALTY ACCESSORIES Radiage /Cosmetic Rejuvenation Radiage /Cosmetic Rejuvenation TM Radiage™ Wands U.S. FDA Approval Pending and only available to our International Doctors TM Radiage™ Radiage™ Wands Radiage™ is a RF non- Tighter skin without surgery U.S. FDA Approval Pending and only available to our International Doctors ablative procedure for skin rejuvenation. It is not a laser. Unlike prior generations, today’s adults are proactive about their health and appearance. They want to RHP05 look as young as they feel. Radiage™ Wand, “Valerii” 5mm, Single-Use, Disposable With increasing numbers, our younger, more active Radiage™ Wand Introductory Kit RHPK/Intro Includes: 3 pcs each of RHP05; RHP10, and RHP15 Wands; 8 pcs RCGI RF Cool Gel™; one package H781 Eye Shields, and one package LIT/DE2 Radiage Patient Education Brochures (50 pcs) It is a patented radio frequency system. Radiage™ Wand Kit, “Valerii” 5mm RHPK05 Includes: 10 pcs RHP05 Wands; 10 pcs RCG1 RF Cool Gel™; one package H781 Eye Shields, and one package LIT/DE2 Radiage™ Patient Education Brochures (50 pcs) patients are having the early signs of aging such as “crows feet” and frown lines. They are requesting RHP10 non-invasive, non-surgical Radiage™ Wand, 10mm, Single-Use, Disposable procedures that have little, if any, down time. Radiage™ Wand Kit, 10mm RHPK10 Includes: 10 pcs RHP10 Wands; 10 pcs RCG1 RF Cool Gel™; one package H781 Eye Shields, and one package LIT/DE2 Radiage™ Patient Education Brochures (50 pcs) RHP15 Radiage™ Wand, 15mm, Single-Use, Disposable Radiage™ Wand Kit, 15mm RHPK15 Includes: 10 pcs RHP15 Wands; 10 pcs RCG1 RF Cool Gel™; one package H781 Eye Shields, and one package LIT/DE2 Radiage™ Patient Education Brochures (50 pcs) (See page 36 for Radiage Patient Education Brochure, Cat. No. LIT/DE2 (See page 57 for Corneal Shields, Cat. No. H781 RF Cool Gel™ The advanced RF Cool-Gel™ incorporates a cryo-gel to cool the skin’s outer surface while the RF energy slightly heats and modifies the soft tissues beneath the skin. 54 DHPG8 RF Cool Gel™, 8 bottles, 18ml. each DHPG15 RF Cool Gel™, 15 oz. bottle with pump top. For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 55 MULTI-SPECIALTY ACCESSORIES MULTI-SPECIALTY ACCESSORIES Ophthalmology/Oculoplastics Ophthalmology/Oculoplastics Patented RF Wedge Resection Electrode Set™ Surgical RF handpiece which Javate-Pamintuan Dacryoplasty (JPD) Electrode EE255 is ergonomically designed in a TEE606 Reusable (set of three) gun shape to reduce the Reusable (2 pcs) Patented RF Wedge Resection Electrode pressure on the hand and fingers and is easier on the TEE237 1/4" tip (2 pcs) wrists during surgical Corneal Shields™ H781 TEE236 TEE235 procedures. 3/16" tip (2 pcs) The ellman® Corneal Shield™ Autoclavable Assorted Package one pair each size, small, medium, large and 1 suction handle 1/8" tip (2 pcs) tautens the skin to allow for more precise incisions. It is an excellent aid when performing periorbital surgery Beigi Minimally Invasive Entropion Electrode H75A H76A H77A TEE603 Sterile/Single-Use (2 pcs) Small - Red (2 pcs, 1 handle) Medium - Green (2 pcs, 1 handle) Large - Blue (2 pcs, 1 handle) and aids in the protection from cautery, desiccation, irritation or trauma, during The Beigi Entropion Electrode is designed to reach deep Ophthalmic Micro-Dissection Electrodes™ Suction Handle (2 pcs) Suction Handle (25 pcs) and after surgery of eyelid and orbital regions. tissue below orbicularis oculi TA10/C1 muscle at the lower border of Reusable. 2” Electrodes 1.5mm of active .004 Wire (2 pcs) the tarsus. TA10/C2 H78A H78B Chedly Eyelid Retractor The Chedly Eyelid Retractor H21A is designed to allow easy Reusable access for oculoplastic (1 pc) Reusable. 2” Electrodes 3.0mm of active .004 Wire (2 pcs) procedures i.e. upper and TA10/C3 lower blepharoplasty, ptosis, Reusable. 2” Electrodes 5.0mm of active .004 Wire (2 pcs) trichiasis and minor Baker Brow Probe EE279 A10 Reusable Set of two (1.5mm and 3.0mm, .004 Wire - one of each) eyelid procedures. Reusable (2 pcs) Note: Add/OP after the Catalog Number to order 1/2” shorter, Ophthalmic Micro-Dissection Electrodes™ Magnified view 56 For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com 57 MULTI-SPECIALTY ACCESSORIES Family Practice/Podiatry ellman® Digit Tourniquets H97 ellman® Cots – Small (12 pcs) H98 ellman® Cots – Medium (12 pcs) H99 ellman® Cots – Large (12 pcs) Ingrown Toenail ECOTS- 4 each small, medium and large ellman ® Cots. Insulated Matrixectomy Electrodes™* The ellman® radiosurgical H9 nail matrixectomy technique Reusable Set of 3 electrodes 1/16” or 3/32” shaft Matrixectomy Electrode Set Includes one each of: H10D, H10E, H10A for Ingrown Toenail allows the matrix to be destroyed electrically with a teflon H1OD 2mm Matrix Electrodes Reusable (2 pc) H1OE 4mm Matrix Spicule Electrodes Reusable (2 pc) H1OA Matrix Spicule (Ball) Electrode Reusable (1 pc) coated electrode, which protects the overlying eponychium. The main advantage of the radiosurgical matrixectomy is that it reduces weeping and Standard Podiatry Electrode Set* S11B Reusable 1/16” or 3/32” shaft Includes one each of: D8, A3, B4, B5, F1, A8 (6 pcs) *Electrodes are displayed in actual size. 58 For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054 For more information, visit our website: www.ellman.com postoperative pain and promotes faster healing. Established in 1955 C N ISO O ® Y C RTIFI ED E The “e” in ellman® stands for Excellence in Quality and Customer Satisfaction. M PA ellman International, Inc. 3333 Royal Avenue, Oceanside, N.Y. 11572-3625 U.S.A. (800) 835-5355 • (516) 594-3333 • Fax: (516) 569-0054 www.ellman.com M7098 Copyright 2008 ellman International, Inc. All Rights Reserved. 0413
Similar documents
Veterinary Catalog 2007
ADHERENCE FREE - Non-sticking of tissue and blood to the RF advanced composition electrode. REDUCED POST-OP PAIN - Reduced swelling and bruising.
More information