low capacity / high pressure

Transcription

low capacity / high pressure
SBC-VPMR
Postbus 468 - 5140 AL
WAALWIJK
+31 (0)416 - 391 999
+31 (0)416 - 392 659
info@ventinet.nl
www.ventinet.nl
Centrifugal backward curved blade fan
low capacities and high pressures
SBC - VPMR
APPLICATIONS
Centrifugal backward curved blade fan
low capacities and high pressures
SBC-VPMR fans are designed for installations requiring modest air deliveries with
relatively high pressures, in duct mounted applications.
For instance: exhausting and filtering of industrial plants, pneumatic conveyance,
transport of solid material mixed with air, sawdust and woodchips.
RANGE
This line consists of 12 sizes with impeller diameter from 350 up to 710 mm.
ADVANTAGES
SBC-VPMR line is characterized by the extreme sturdiness due to the rigid
construction in enamelled sheet metal and the thickness of the materials.
Another feature is the variety of models and versions composing the series.
CONSTRUCTION
Volute in epoxy painted enamelled steel sheet.
Fixing flanges according to ISO 6580 / EUROVENT 1-2 standards.
High efficiency backward curved blade impeller.
Balancing according to ISO 1940.
Asynchronous three or single phase, electric motor, protection IP 55,
insulation class F, service S1, mounting type B3 or B5,
construction according to IEC/EEC (UNEL MEC).
Arrangement 4 or 5
(impeller directly coupled to motor shaft)
Arrangement 1, 9, 12
(belt driven, with impeller coupled to the motor by mean of transmission).
TECHNICAL SPECIFICATIONS SBC-VPMR standard
Conveyed air: very dusty, conveyence solid materials.
Temperature of conveyed air: -20°C / +80°C.
Voltage:
three phase version (T) 400V – 50Hz.
single phase version (M) 230V – 50Hz
ARRANGEMENTS
SBC-VPMR arrangement 4:
impeller directly coupled to motor shaft, motor placed on the motor support.
SBC-VPMR arrangement 5:
impeller directly coupled to motor shaft, motor flanged on the fan volute.
ACCESSORIES
Inlet protection grid (Necessary for use in free air)
Outlet protection grid (Necessary for use in free air)
Inlet flexible joint
Outlet flexible joint
Inlet counter flange
Outlet counter flange
Inspection door
AV mounts
Condensation drain
ON REQUEST
Spark proof, explosion proof versions (SBC-VPMR atex).
Stainless steel versions.
High temperature versions
(150°C for direct coupling and 300°C for belt coupling versions).
SBC-VPMR
Discharge angles
RD 0
RD 45
RD 90
RD 135
RD 180
RD 225
RD 270
RD 315
LG 0
LG 45
LG 90
LG 135
LG 180
LG 225
LG 270
LG 315
RD
LG
1
SBC-VPMR Performances
1 mm H2O= 9,8 Pa
2 POLES (3000 rpm) - T: three-phase (3Ph-400V-50 Hz)
Model
Pm
(kW)
In max
(A)
Mot
(H)
Lp
dB(A)
352/A T
352/B T
402/A T
402/B T
452/A T
452/B T
502/A T
502/B T
0,75
1,1
1,5
2,2
3
4
4
5,5
1,9
2,5
3,2
4,7
6,1
7,5
7,5
10,4
80
80
90
90
100
112
112
132
69
70
74
75
76
77
80
84
Pt (mm H2O)
Performance shown in the selection diagrams refer to air at 15°C temperature and 0 mt a.s.l. altitude, and they were obtained in installation type “D” with no grid nor accessories.
550
502B
525
500
502A
475
450
452B
425
400
452A
375
350
402 B
325
300
402A
275
250
352B
352A
225
200
175
150
125
100
0
500
1.000
1.500
2.000
2.500
3.000
3.500
4.000
4.500
5.000
2 POLES (3000 rpm) - T: three-phase (3Ph-400V-50 Hz)
Model
Pm
(kW)
In max
(A)
Mot
(H)
Lp
dB(A)
562/A T
562/B T
632/A T
632/B T
712/A T
712/B T
7,5
11
15
18,5
22
30
13,9
19,9
26,2
32,1
40,4
53,2
132
160
160
160
180
200
86
87
88
89
91
92
Pt (mm H2O)
Q (m3/h)
1.100
1.050
712B
1.000
950
712A
900
850
632B
800
750
632A
700
650
562B
600
550
562A
500
450
400
350
300
250
200
0
2.000
4.000
6.000
8.000
10.000
12.000
14.000
4 POLES (1500 rpm) - T:Three-phase (3Ph-400V-50 Hz)
Model
Pm
(kW)
In max
(A)
Mot
(H)
Lp
dB(A)
714/A T
714/B T
804/A T
804/B T
4
5,5
7,5
9,2
8,3
11
14,6
18
112
132
132
132
71
72
74
75
Rpm =
Pm =
In =
Lp =
Pt (mm H2O)
Q (m3/h)
Nominal motor speed
Motor power
Absorbed current
Sound pressure level in measured in free
field at 1.5 m from the fan, in any direction,
with ducted inlet and outlet.
Noise tolerance: +3dB(A)
Absorbed power tolerance: +3%
325
804B
300
804A
275
714B
250
714A
225
200
175
150
0
1.000
2.000
3.000
4.000
5.000
6.000
7.000
8.000
9.000
10.000
Q (m3/h)
2
SBC-VPMR
Dimensions
Model
Mot
(H)
Pm Kg
(kW)
352/A T
352/B T
402/A T
402/B T
452/A T
452 B T
502/A T
502/B T
562/A T
562/B T
632/A T
632/B T
712/A T
712/B T
714/A T
714/B T
804/A T
804/B T
80
80
90
90
100
112
112
132
132
160
160
160
180
200
112
132
132
132
0,75
1,1
1,5
2,2
3
4
4
5,5
7,5
11
15
18,5
22
30
4
5,5
7,5
9,2
Arrangement 4
Fan
A
32
36
48
52
63
78
93
106
133
141
193
206
276
396
186
196
286
291
B
C
D
Base
E
370
535 250 615
370
425
590 280 658
425
510
645 300 715
510
525
715 335 795
585
605
805 375 890
740
760
910 425 1000
760
785
1015 475 1122
860
585
1015 475 1122
650
675
1140 530 1265
675
65
71
78
86
95
105
115
115
127
Dimensioni in mm/Dimensions in mm
H
F
G
0°
135°
180°
225°
270°
315°
I
L
M
N
O
P
Ø
215
56
355
250
355
121
14
180
45
203
225
10
238
63
375
280
375
133
17
205
55
234
260
10
265
70
400
300
400
197
23
250
30
289
324
12
297
78
450
335
450
337
89
500
375
500
23
28
250
300
300
415
30
40
40
50
289
337
337
395
324
372
372
440
12
14
381
99
560
425
560
426
108
630
475
630
426
108
630
475
630
481
122
710
530
710
197
237
237
337
337
337
357
381
197
237
28
415
50
395
440
14
33
39
23
23
460
500
250
300
70
80
30
40
434
506
289
337
488
568
324
372
17
19
237
23
300
40
337
372
12
23
12
12
Peso ventilatore in kg (completo di motore) • Weight of fan in kg (complete with motor)
B
(fig. 1)
Outlet flange
(fig. 2)
d1
d1
d2
n°
Ø
a
b
a1
b1
a2
b2
n1xp
n2xp
n°
Ø
185
205
228
255
285
320
360
405
219
241
265
292
332
366
405
448
250
275
298
325
365
400
440
485
8
8
8
8
8
8
8
12
8
8
8
10
10
10
10
10
146
166
185
207
231
258
288
322
105
117
131
148
166
185
205
229
182
200
219
241
265
292
332
366
139
151
165
182
200
219
249
273
216
236
255
277
301
328
368
402
175
187
201
218
236
255
285
309
1X112
1X112
1X112
1X125
1X125
1x112
1x112
1x112
1x112
1x112
2x112
2x125
2x125
6
6
6
8
8
10
10
10
12
12
12
12
12
12
12
12
d2
b1
n 1p
(fig. 2)
a
a2
d
a1
n 2p
350
400
450
500
560
630
710
800
(fig. 1)
Inlet flange
Model
Dimensions in mm
3
b
b2
SBC - VPMR Spare parts
Arrangement
4
7
9
8
33
1
26
6
4
2
3
30
35
7
9
Arrangement
5
8
30
1
3
2
4
6
38
35
P
RIPTI
1 - Inlet protection grid
2 - Inlet counter flange
3 - Inlet flexible joint
4 - Inlet nozzle
6 - Impeller
7 - Outlet protection grid
8 - Outlet counter flange
9 - Outlet flexibile joint
17 - Single-block support
18 - Pulley
19 - Bush
21 - Belt transmission guard
22 - Base
24 - Motor slides
25 -Threaded drawplates for tensioning
26 - Eletric Motor
30 - Inspection door
31 - V-belts
32 - Tipper
33 - Motor supporting base (pedestal)
35 - Fan frame
38 - Motor holding disc
42 - Sigle-block protecting guard
43 - Drain plugs
44 - Carter supporting brackets
45 - Tipper support
49 - Joint-cover guard
4
26
SBC - VPMR
Spare parts
Arrangement
9
7
43
9
8
1
6
4
2
3
35
Arrangement
12
45
32
7
43
9
8
31
19
42
17
26
19
21
42
1
2
3
4
6
30
17
26
25
35
24
18
22
P
RIPTI
1 - Inlet protection grid
2 - Inlet counter flange
3 - Inlet flexible joint
4 - Inlet nozzle
6 - Impeller
7 - Outlet protection grid
8 - Outlet counter flange
9 - Outlet flexibile joint
17 - Single-block support
18 - Pulley
19 - Bush
21 - Belt transmission guard
22 - Base
24 - Motor slides
25 -Threaded drawplat for tensioning
26 - Eletric Motor
30 - Inspection door
31 - V-belts
32 - Tipper
33 - Motor supporting base (pedestal)
35 - Fan frame
38 - Motor holding disc
42 - Sigle-block protecting guard
43 - Drain plugs
44 - Carter supporting brackets
45 - Tipper support
49 - Joint-cover guard
5
44
18
31
44
21
Notes
Centrifugal fans wit bac war curve im eller
Postbus 468 - 5140 AL
WAALWIJK
+31 (0)416 - 391 999
+31 (0)416 - 392 659
info@ventinet.nl
www.ventinet.nl
Centrifugal fans wit forwar curve im eller
Axial ring fans
Axial wallmountin fans
Axial uct fans
Centrifugal inline fans
ooffans
For more information contact our sales team or visit our website:
www.ventinet.nl

Similar documents