BR-17882A Hemoccult ICT Testing Highly Specific
Transcription
BR-17882A Hemoccult ICT Testing Highly Specific
FECAL IMMUNOCHEMICAL TEST (FIT) Blood Banking Centrifugation Highly specific for lower GI bleeding. Chemistry Flow Cytometry No drug or diet restrictions. Hematology Immunoassay Information Systems Lab Automation Molecular Diagnostics Rapid Diagnostics As a healthcare professional, you’re constantly analyzing and evaluating a patient’s health by asking questions, looking at the facts, the numbers, the odds and more. Deciding what fecal occult blood test (FOBT) is best shouldn’t be any different. Don’t take chances with your patient’s health—insist on a test that has been clinically proven for safety and effectiveness over the course of time. BR-17882A FECAL IMMUNOCHEMICAL TEST (FIT) Hemoccult ICT Offers Excellent Stability Unlike other FIT products, Hemoccult is developed with dry-sample collection method, which increases stability of the sample, allowing for multiple-day collection and necessary transit/development time. Clinical fact: Hemoglobin is stable in dried stool samples.1 Higher Sensitivity and Specificity Clinically proven to have an apparent specificity of 99.1% and relative sensitivity of 100%. Clinical fact: Sensitivity of Hemoccult ICT is based on clinical studies.2 No Drug or Dietary Restrictions Hemoccult ICT is specific to intact human hemoglobin, eliminating interactions from red meat, Vitamin C and other factors that lead to false positives. Clinical fact: An FIT is highly specific for lower gastrointestinal bleeding. Multiple-Day Testing Meets the American Cancer Society, United States Task Force for Colorectal Cancer Foundation screening recommendation of multiple-day testing for colorectal cancer. Clinical fact: Clinical trials support 2- and 3-day stool sampling.3 An FIT yields inherently superior results when compared to a chemical-based test (e.g., guaiac). Hemoccult ICT Hemoccult Guaiac What’s Detected Intact Human Hemoglobin Protein Peroxidase Activity (Heme) Probable Location of Bleeding Large Intestine (Lower GI) (Colon) Only Mainly Stomach, Small Intestine and Large Intestine Dietary or Drug Restrictions None Yes False Positivity Rate For Any Lower GI Pathology 0.9% 1.2% Clinical Apparent Specificity (100% False Positivity Rate) 99.1% 98.8% Clinical Relative Sensitivity (Adenomas and Cancer) 100% 40% Analytical Sensitivity 95% at 300 ug Hemoglobin/g Feces or 200 ng/mL Hemoglobin 50% at 0.3 mg Hemoglobin/gm Feces (100% at 1 mg Hemoglobin/gm Feces) Table data2 Step-By-Step Patient Instructions Easy-to-follow directions are included for filling out Collection Card information, collecting stool samples and options for returning samples to the doctor or laboratory. Flexible Design ICT tests are available as 2- and 3-day tests in single-card configurations, enabling you to choose the solution that works best for your patient. FECAL IMMUNOCHEMICAL TEST (FIT) Support For You and Your Patients Some of the educational tools to help you promote colorectal cancer (CRC) screening include: - FIT screening experts at your call - Patient checklist - Patient reminder cards - Technical hotline - Webinars on-demand - CRC awareness poster - Patient sample collection video - 24/7 web communication For Hemoccult ICT product samples, information and educational support to help you understand the facts around fecal immunochemical testing (FIT), please visit www.beckmancoulter.com CLIA • CPT Code* • Waived G0328QW, 82274QW Ordering Information Hemoccult ICT Products FIT 3-Day Patient Screening Kit 395066 40 Patient Screening Kits, each containing: • Dispensing Envelope with Patient Instructions • Hemoccult ICT Collection Cards • Flushable Sample Collection Tissues • Applicator Sticks • Mailing Pouch FIT 2-Day Patient Screening Kit • 1 00 Collection Cards • 100 Applicator Sticks • Sample Collection Instructions 395067† • 2 0 Test Devices • 1 Bottle Hemoccult ICT Buffer/8.0 mL †To be used with Hemoccult ICT Collection Cards – product # 395066, 395261 and 395065 Hemoccult ICT Controls 395068 • 4 Bottles (2 Positive and 2 Negative / 0.8 mL each) 395261 50 Patient Screening Kits, each containing: • Dispensing Envelope with Patient Instructions • Hemoccult ICT Collection Cards • Flushable Sample Collection Tissues • Applicator Sticks • Mailing Pouch Hemoccult ICT Collection Cards Kit Hemoccult ICT Test Kit Hemoccult ICT Buffer 462595 • 1 Bottle of Buffer *E xemplar CPT provided. Refer to regional CMS fee schedule for relevant/current CPT codes. 395065 FECAL IMMUNOCHEMICAL TEST (FIT) Beckman Coulter is the leader in fecal occult blood testing and offers the very best in rapid tests designed to simplify the diagnostic process. Early detection is the single most important advantage a patient can have to survive life-threatening diseases. Beckman Coulter provides the tools and tests physicians need to aid in the diagnosis and management of a variety of disease states. Beckman Coulter also provides a variety of Immunoassay, Chemistry, Hematology and Centrifugation instruments to aid in the diagnosis and management of a full spectrum of medical conditions. Each system’s compact design and cost-effective performance makes it a perfect complement to a physician’s office laboratory. To order product, contact your medical supply distributor. For technical assistance regarding rapid test kits, call Technical Marketing at 800-877-6242 or email askpcd@beckman.com. Lab Testing Made Easy Beckman Coulter Rapid Diagnostics Product Offering Hemoccult Hemoccult SENSA Hemoccult II SENSA elite Hemoccult ICT CLIA-waived rapid tests for the detection of hidden blood in feces Gastroccult CLIA-waived rapid test for detecting hidden blood in gastric fluid and determining gastric pH ICON Hp CLIA-waived (whole blood) and moderately complex (serum) rapid test for the detection of antibodies to H. pylori ICON 20 hCG ICON 25 hCG CLIA-waived (urine) and moderately complex (serum) rapid tests for the detection of hCG ICON Mono CLIA-waived (whole blood) and moderately complex (serum) antibody test for infectious mononucleosis ICON DS Strep A ICON SC Strep A CLIA-waived dipstick and cassette rapid format tests for the detection of Strep A, using throat swab sample References: 1. Data on file, Beckman Coulter, Inc. 2. Data on file, Beckman Coulter, Inc. Hemoccult ICT Product Instructions 2010 3. Yamamoto M; Nakama H. Cost-Effectiveness Analysis of Immunochemical Occult Blood Screening for Colorectal C ancer Among Three Fecal Sampling Methods. Hepato-Gastroenterology 2000; 47(32):396-399 Beckman Coulter, the stylized logo, Hemoccult, Hemoccult II, SENSA, Gastroccult and ICON are trademarks of Beckman Coulter, Inc. and are registered with the USPTO. For Beckman Coulter’s worldwide office locations and phone numbers, please visit www.beckmancoulter.com/contact BR-17882A B2012-13692-01 www.beckmancoulter.com © 2013 Beckman Coulter, Inc.