~TiJPV
Transcription
~TiJPV
)!.. ~TiJPV VOP-026 Sternberk, s.p. division VTUPV Vyskov The certified quality system according to CSN EN ISO 9001 Task 1 Order No 68/6403 /001-053 Test Report No: 6430-15212008 1 Equipment Testing Centre -Testing Laboratory No. 1103 Copy No: accredited by CAl according to CSN EN ISO/IEC 17025 Pages Number: 5 L 1103 Annex: - CONSTRUCTION PARTS TESTING AND SPECIAL MEASUREMENT LAB ORATORY TEST REPORT SEISMIC QUALIFICATION TEST Name and address of submitter (customer): 1& C Energo, a.s. , Praiska 684/49,67401 Tfebie, The Czech Republic Identification: Panel instruments OM 602 AV, OMB 451 UNT, OMB 452 UNT, Converter OMX 39PM, producer Orbit Merret; Converter iTemp TMT 182, producer Endress+Hauser; Converter PRETOP 5335B, producer PR electronics; Mosaic panel MAUELL M18MK (anal, Shoving device type PF 72 x 36, switch type MU 2 12 01 , button type 704.074.210), producer Helmut Mauell GmbH; Rotary switch OMEGA SWI44G-12-B, producer Omega; Coupling cabinet Weidmiiller FPC 30/4011 3 within clamps Serial number: Producer: Technical documentation: Date of entrance test: Test method: 18 December 2008 Date of test, place of test: 18 December 2008 CSN IEC 980: 1993, par. 6 Test leader: lng. lift LENIKUS ZKSaSM (Mechanical test room) Test carried out by: ;/;;{;;- L~~-:J lng. lifi LENIKU,S ~ lng. Ivan BRADAC . / --..-J /---Authorize'!, by technicaf manag'Z·, . ,;;.,...<:' lng. Ivan STUCHAL ~f'(. v Issue date: 19 December 2008 _____ /1/1/1/ (~. :7 (." r .~~ P. .' .," -.~ • ". ~ ) '. Test results: I "· / The tested equipment was exposed to the seismic qualification test according to CSN IEC 980 ( 1993, par. 6 (in frequency range 1 Hz - 33 Hz). There was no mechanical failure or damage caused by tests, the test item under tests found to be functional during tests and after tests. The test result is relating for specific line types. The expanded measurement uncertainty is a product of a measurement standard uncertainty and a coverage factor K=2, this corresponds to a coverage probability 95 % offor a normal distribution. ADRESS: Telephone: Fax: E-mail: VOP-026 Sternberk, s.p. division VTUPV Vyskov OZT - ZL <:.1103 V. Nejedleho 691 682 03 VYSKOV (CZE) Notes: 517303623 517303605 i.stuchal@vtupv.cz The results contained within this report relates to the tested item only. This report shall not be reproduced except in full, without written approval of testing laboratory. .v:f1Pv. 1 6430-152/2008 19.12.2008 The test item The items of the testing were these devices: 2 • Panel instrument OM 602 AV, producer Orbit Merret, ser. number: 1080505002 • Panel instrument OMB 451 UNI, producer Orbit Merret, ser. number: 1081104192 • Panel instrument OMB 452 UNI, producer Orbit Merret, ser. number: 1081104190 • Converter on a DIN strip OMX 39PM, producer Orbit Merret, ser. number: 1081104193 • Two-conductor converter with protocol Endress+Hauser, ser. number: A40B4804125 • Two-conductor converter with protocol HART: PRETOP 5335B, producer PR electronics, ser. number: 070902240 • Mosaic panel MAUELL MI8-MK (shoving analog device type PF 72 x36, measuring places switch type MU 2 12 01, button for emergency shutdown type 704.074.210), producer Helmut Mauell GmbH • Rotary switch OMEGA SWI44G-12-B, producer Omega, ser. number: QC#PL112027 • Coupling cabinet Weidmiiller FPC 30/40/13 within clamps. HART: iTemp TMT 182, producer The test aim The aim of the test was to verify seismic qualification of the tested device in specific performance according to CSN IEC 980: 1993 par. 6. The test was performed according to the specification for seismic testing for nuclear power plant Dukovany, rep002-07.vys, revO", with amplification factor 4.5, for SO 805 + 14.7 m and SO 806 +9.6 m for EDU, with acceptance of the specification for EDU R080-2005-12.edu. During and after the test will be a functional check performed. 3 The test procedure and Test results The tested items were fastened on the panel and on the console made of the steel profiles which enabled fastening on the shaking table. The devices were connected via conductors. This enabled connection to the control devices. Continuous control of the mechanical damage was made visually during and after the testing, control of the function during the seismic testing. Before the testing was an entering inspection made so as the control of the device connection and a functional check - without defects. 3.1 Resonance search test - axis ex, Y, Z) The test was carried out with swept sinusoidal vibrations in the frequency range 2 Hz - 50 Hz with constant amplitude of acceleration 0,2 g, s with sweep rate 0,2 Hzlsec in all of the three orthogonal axis. Order of the equipment during the test is on pictures 1-8. Console with devices: Axis X Axis Y Axis Z No resonation 45.8/49.0 44.5 After the test was made control check of the equipment for mechanical dJ;#?1~O i ;Uf.Je:' 2/5 '~~ vTilPy 6430-152/2008 19.12.2008 3.2 Seismic qualification test in longitudinal axis ex) The devices were connected to the measuring equipment. The test was carried out under 100% excitation with time dependent acceleration according to the specification (longitudinal axis X). During the test were all devices functional. Panels with devices during the testing procedure are captured on pictures. 1 and 2. 3.3 Seismic qualification test in transversal axis (Y) The devices were connected to the measuring equipment. The test was carried out under 100% excitation with time dependent acceleration according to the specification (transversal axis Y). During the test were all devices functional. Panels with devices during the testing procedure are captured on pictures 3, 4. 3.4 Seismic qualification test in vertical axis (Z) The devices were connected to the measuring equipment. The test was carried out under 100% excitation with time dependent acceleration according to the specification (vertical axis Z). During the test were all devices functional. Panels with devices during the testing procedure are captured on pictures 5, 6. 6.2 Functional test and post-test check After the testing procedure was a functional test and after test control of the tested equipment made. There was no mechanical damage found and all devices were functional. 4 Uncertainty: Extended uncertainty of acceleration measurement ± 2%. 5 Used measuring devices: Name Inventory number 53663 53664 1060452/9 96014609 Accelerometer B&K 4513 Accelerometer B&K 4513 Accelerometer M353B18 SN 67962 Accelerometer 353B33 SN 85348 Calibration validity 25 .12.2008 25 .12.2008 24.0l.2009 04.0l.2009 KL c. 53663 Bruel & Kjaer KL c. 53664 Bruel & Kjaer KL c. 8012-KL-2050-07 CMI Praha KL c. 8012-KL-2014-07 CMI Praha 6 Graphical Comparison of the required response spectrum and the test response spectrum 6.1 Comparison for X axis (RRS required response spectrum, TRS test response spectrum) 8 I - 7 ffl 6 RRSX - TRSX - 3 , 5 Hz 1(\-\ 5 ~~ } 3 ~ Jr 2 o c- - 1 0 --- .......... -- 1'______ 10 20 Frekvence [Hz] 3/5 I 30 / 4Q vTiIPv 6430-152/2008 19.12.2008 6.2 Comparison for Y axis (RRS required response spectrum, TRS test response spectrum) 8 .. 7 I I - ~I 6 RRSY - TRSY - 3 , 5 Hz I r-\ 5 'c .9! 4 .c (.) >. N 3 r-l h Ir ~ " 2 --...... 1 _ _ _ _ _ j o ~ o 10 20 Frekvence [Hz] 30 40 6.3 Comparison for Z axis (RRS required response spectrum, TRS test response spectrum) 4,-----------,-----------,------------,----------- - RRSZ - TRSZ - 3 , 5 Hz 'c ~ 2+---~----~+-~~~~--~-----------r----------~ (.) ~ N ~, 0 0 10 20 Frekvence [Hz] 4/5 30 40 t~ VT1lPv 7 6430-152/2008 19.12.2008 Photo-documentation Pict. 1, 2: Test in X axis Pict. 3, 4: Test in Y axis Pict. 5, 6: test in Z axis 5/5 .. ..,'.."' "., " I:, O;r,~" . .' -r-nberk, s.p. . ' 1./175 'K I ['"TER NBftl Jo .,.. t' .. '. '. ,. ,# , ... - J. t." CD v yskov Pages Number: 2 N. of attachments: - TECHNICAL COMMENTARY to test results - test report No. 6430-152/2008 Name and address of the sponsor (costumer): 1& C Energo a. s., PraZska 684/49,67401 Trebie, The Czech Republic Tested items: • Panel instrument OM 602 AV, producer Orbit Merret, seL number: 1080505002 • Panel instrument OMB 451 UNI, producer Orbit Merret, seL number: 1081104192 • Panel instrument OMB 452 UNI, producer Orbit Merret, seL number: 1081104190 • Converter on DIN strip OMX 39PM, producer Orbit Merret, seL number: 1081104193 • Two-conductor converter with protocol HART: iTemp TMT 182, producer Endress+Hauser, seL number: A40B4804125 • Two-conductor converter with protocol HART: PRETOP 5335B, producer PR electronics, ser. number: 070902240 • Mosaic panel MAUELL MI8-MK (analog shoving device type PF 72 x36, measuring places switch type MU 2 12 01, button for emergency shutdown type 704.074.210), producer Helmut Mauell GmbH • Rotary switch QC#PL112027 • Coupling cabinet Weidmliller FPC 30/40/13 within clamps. OMEGA SWI44G-12-B, producer Omega, seL number: People that participate: By VTl)PV: Ing. JUi Lenikus Ing. Ivan Bradcic By I & C Energo M. Sloboda P. Horak Tested components (devices), which are typical species of production lines used on EDU, were tested on seismic resistivity according to CSN IEC 980. The test was carried out in harmony with the specification for seismic testing for nuclear power plant Dukovany, rep00207.vys, revO", with amplification factor 4.5, for SO 805 +14.7 m and SO 806 +9.6 m for EDU, with a respect to the specification for EDU R080-2005-12.edu.for EDU R080-200512.edu. During the testing were devices connected to a grid 230 V. The disconnection of the signal was controlled via viewing device Yokogava of the model series DXI00 SN 27CA33489 2. Output signals were before, during and right after the seismic test without signal interruption. There was no mechanical or other damage (loosening or displacement) found. The electrical functionality of the tested devices and components was not disrupted and there was no fake signal during and after the testing found. During and after the testing were no defects found, devices were functional, parameters matched to the prescribed values. Technical commentary to the results of the tests has only an informational character and is above accreditation of the test department. lng. Ivan Stuchal Vyskov: 19 December 2008 2