Bill acceptor ICT P70 P77

Transcription

Bill acceptor ICT P70 P77
P70/P5
series
Bill Acceptor
Installation Guide
P77/P5
www.igrotechnics.ru
2005 International Currency Technologies Corporation
V. 5.0 Part Number : H4814D-R
P85/P5
International Currency Technologies Corp.
Contents
1. Introduction ...............................................................................2
1-1. Overview.............................................................................2
1-2. Features .............................................................................2
2. Specifications ............................................................................3
General ......................................................................................3
Electrical ....................................................................................3
Use of Materials Limitations
International Currency Technologies Corporation (ICT) all rights reserved.
All materials contained are the copyrighted property of ICT.
All trademarks, service marks, and trade names are proprietary to ICT.
ICT reserves the right at all times to disclose or to modify any information as
ICT deems necessary to satisfy any applicable law, regulation, legal process
or governmental request, or to edit, refuse to post or to remove any information
or materials, in whole or in part, in ICT's sole discretion.
Mechanical ................................................................................4
3. Packing List ...............................................................................4
4. Dimension .................................................................................5
4-1. Bezel Application ..............................................................10
5. Installation ...............................................................................14
5-1. Harness Application .........................................................14
5-1-1. I/O Circuit ...............................................................21
5-2. DIP Switch Setting ...........................................................26
5-3. Software Download and Upgrade ....................................27
6. Maintenance ............................................................................28
7. Troubleshooting .......................................................................29
www.igrotechnics.ru
1
www.ictgroup.com.tw
P Series
P Series
2. Specifications
1. Introduction
1-1. Overview
General
P series is a new generation of bill acceptor designed by ICT which
features high-security with acceptance rate up to 96%. In addition,
multiple bezel and bill box selections offer users the most convenient
and complete services.
Acceptance Rate
96% or greater
*Note: The Incomplete bills such as extremely dirty, wet, broken, or wrinkled ones
are excluded!
Bill Insertion
Four way acceptable
Transaction Time
Approx. 3 seconds to stack
Approx. 2 seconds without stacking
Interface
Four ways bill insertion acceptance.
Pulse, ICT Protocol, ccTalk,ID003,
MDB, GPT, IGT
High acceptance rate.
*Combination is possible. Ex. Pulse+MDB.
1-2. Features
Multiple bezel selections.
Stacker with capacity of 200 or 500 bills are available.
Installation: Indoor use only!!
High security by protective mechanism.
Electrical
www.ictgroup.com.tw
Power Source
12V DC (11.4~12.6V DC)
Power Consumption
Standby: 0.21A~0.35A (2.5W~4.2W)
Operation Current: 2A, 24W
Motor Lock: 2.2A, 26.4W
Operation Environment
Operation Temperature: 0°C~55°C
Storage Temperature: -20°C~70°C
Humidity: 30%~85%RH
(no condensation)
www.igrotechnics.ru
2
3
www.ictgroup.com.tw
P Series
P Series
4. Dimension
P70
Weight
0.65~0.75kg (Stackerless)
1.5 ~1.65kg (With Stacker)
Bill Accepted Width
P70-P5 : 62mm~70mm
P77-P2/P5: 66mm~77mm
P85-P5 : 68mm~85mm
39.8[1.57]
P2: Approx. 200 bills
P5: Approx. 500 bills
82.3[3.24]
12.4[0.49]
Bill Box Capacity
5.3[0.21]
14.2[0.56]
P70/P5
: Refer to page. 5
P77/P2/P5: Refer to page. 6
P85/P5 : Refer to page. 8
114.9[4.53]
102.4[4.03]
84.9[3.34]
120.8[4.75]
89.6[3.53]
53.4[2.10]
Outline Dimension
figure 1.
93.0[3.66]
84.0[3.31]
51.0[2.01]
134.0[5.28]
117.0[4.61]
Mechanical
Unit:mm[inch]
P70-P5
Harness: Refer to 5-1
P Series Installation Guide
P Series DIP Switch Setting Guide
83.0[3.27]
www.ictgroup.com.tw
www.igrotechnics.ru
4
39.8[1.57]
95.9[3.78]
Accessory
30.0[1.18]
17.5[0.69]
120.3[4.74]
80.9[3.19]
44.9[1.77]
13.7[0.54]
Bill Acceptor
169.7[6.68]
287.3[11.31]
Main
134.0[5.28]
125.5[4.94]
120.3[4.74]
3. Packing List
13.7[0.54]
8.5[0.33]
figure 2.
93.0[3.66]
84.0[3.31]
51.0[2.01]
Unit:mm[inch]
5
www.ictgroup.com.tw
P Series
P Series
P77 (Down Stacker Type)
figure 3.
5.3 [.209]
figure 5.
100.0[3.937]
84.0[3.307]
50.8[2.000]
128.4[5.055]
108.4[4.268]
90.9[3.579]
Unit:mm[inch]
figure 4.
175.00[6.890](500P)
www.igrotechnics.ru
6
120.5[4.744]
4.00[.157]
17.50[.689]
37.50[1.476]
Unit:mm[inch]
Unit:mm[inch]
www.ictgroup.com.tw
73.53[2.895]
120.50[4.744]
134.00[5.276]
124.50[4.902]
73.53[2.895]
36.17[1.424]
9.50[.374]
12.70 [0.50]
278.10[10.949]
28.30[1.114]
80.10[3.154]
127.00[5.000](200P)
175.00[6.890] (500P)
50.80[2.000]
84.00[3.307]
85.00[3.346]
100.00[3.937]
92.00[3.622]
73.5[2.895]
figure 6.
92.00[3.622]
127.00[5.000](200P)
80.10[3.154]
28.30[1.114]
66.53[2.619]
29.17[1.149]
134.00[5.276]
119.70 [4.71]
276.60[10.890]
125.50[4.941]
134.00[5.276]
4.00[.157]
P77-P2/P5 (Up Stacker Type)
13.50[.531]
36.17[1.424]
17.50[.689]
Unit:mm[inch]
8.50[.335]
125.50[4.941]
134.00[5.276]
37.50[1.476]
8.50[.335]
100.00[3.937]
85.00[3.346]
84.00[3.307]
50.80[2.000]
124.50[4.902]
66.53[2.619]
29.17[1.148]
9.50[.374]
P77-P2/P5 (Down Stacker Type)
36.2[1.424]
29.5[1.161]
13.5 [0.531]
81.5[3.209]
117.0[4.606]
134.0[5.276]
81.50[3.209]
23.70[.933]
120.50[ 4.744]
104.83[4.127]
67.47[2.656]
13.50[.531]
117.00[4.606]
134.00[5.276]
23.0[.906]
128.40[5.055]
108.40[4.268]
90.90[3.579]
28.80[1.134]
5.30[.209]
100.00[3.937]
84.00[3.307]
50.80[2.000]
P77 (Up Stacker Type)
7
www.ictgroup.com.tw
P Series
84.0 [3.31]
50.8 [2.00]
14.0 [0.55]
8.5 [0.33]
14.0 [0.55]
106.0 [4.18]
117.0 [4.61]
134.0 [5.28]
134.0 [5.28]
106.0 [4.18]
54.9 [2.16] 34.1 [1.34]
figure 7.
50.8 [2.00]
92.0 [3.62]
100.0 [3.94]
107.8 [4.25]
To install the bill acceptor on your VMC, please be aware of the
dimension as below:
[ L ] : Longer than the maximum length of accepted bills.
[ L1 ] : Bill box capacity depth.
* [ L/2 ] has to be longer than 70mm to open upper base.
13.5 [0.53]
27.2 [1.07]
87.2 [3.44]
5.3 [0.21]
Figure.9
Unit:mm[inch]
P85-P5
L/2
P85
P Series
figure 8.
8.50[.335]
31.18[1.227]
80.10[3.154]
28.35[1.116]
L
134.00[5.276]
120.00[4.724]
65.11[2.563]
31.03[1.222]
14.00[.551]
17.50[.689]
4.00[.157]
174.78[6.881]
L1
275.75[10.856]
125.50[4.941]
134.00[5.276]
125.00[4.921]
65.11[2.563]
14.00[.551]
9.00[.354]
L
100.0[3.937]
92.0[3.622]
84.0[3.307]
50.8[2.000]
99.00[3.898]
www.igrotechnics.ru
Unit:mm[inch]
www.ictgroup.com.tw
8
9
www.ictgroup.com.tw
P Series
P Series
4-1. Bezel Application
P70
Bill Accepted Width: 62mm~70mm
Table 1.
Figure
P77
Bill Accepted Width: 66mm~77mm
Table 2.
Figure
Name
Break Proof Bezel
Module(Green)
Break Proof Bezel
Module(Green-Russia)
Name
Metal Bezel
Part Number
3RBA-FAC23XXX
3RBA-FAC24XXX
Part Number
3RBA-STP07XXX
Mounting Kits
Application
V
V
Mounting Kits
Application
Tricolor Marquee Bezel Tricolor Marquee Bezel
(Down Stacker)
(Up Stacker)
3RBA-FAC22XXX
3RBA-FAC39XXX
V
V
Figure
www.ictgroup.com.tw
Name
Self-color Marquee
Bezel
Green Bezel Module
(Non Step Style)
Green Bezel Module
(Step Style)
Part Number
3RBA-FAC22XXX
3RBA-FAC25XXX
3RBA-FAC26XXX
Mounting Kits
Application
V
V
V
www.igrotechnics.ru
10
11
www.ictgroup.com.tw
P Series
P Series
P77
Bill Accepted Width: 66mm~77mm
Table 3.
P85
Bill Accepted Width: 68mm~85mm
Table 4.
Figure
Figure
Name
Angular Snout Bezel
Marquee Break Proof
Bezel (Aluminum)
S Type
Marquee Bezel
Part Number
3RBA-FAC29XXX
3RBA-FAC40XXX
3RBA-FAC43XXX
Mounting Kits
Application
Name
Bezel Module
(Green)
Part Number
3RBA-FAC27XXX
Mounting Kits
Application
V
Figure
Name
Horizontal Bezel
Module
Part Number
3RBA-FAC21XXX
Mounting Kits
Application
www.ictgroup.com.tw
www.igrotechnics.ru
12
13
www.ictgroup.com.tw
P Series
P Series
5. Installation
Figure 10.
WEL-R7U06
17
Extension Wire
CU-R961-1
15
Power & *Data Comm.
WEL-R7U02
16
Extension Wire
CU-R961-1
15
Power & *Data Comm.
WEL-R7U02
16
*Data Comm.
WEL-RP703
19
Power
WEL-R061
20
* Data Comm. : Data Communication.
** Plug-in Board: (1) ccTalk: 5RBG-AA248M2-04-2
(2) MDB : (New) 5RBG-AA313NA0-01
(Old) 5RBG-AA266NA0-01
www.ictgroup.com.tw
DC 12V
#CU-R961-1
www.igrotechnics.ru
14
+AMP
15
.165inch or 4.2mm
*Data Comm.
AMP 172332-1 BACK VIEW
16
9
WEL-R7U02
8
15
Power
7
16
CU-R961-1
PIN 1- YELLOW...........................INHIBIT+
PIN 2- GREEN..............................INHIBITPIN 5- RED...............+12VDC(POWER-IN)
PIN 7- BLUE...............CREOIT-RELAY-NO
PIN 8- PURPLE.......CREDIT-RELAY-COM
PIN 9- ORANGE.............GND(POWER-IN)
WEL-R7U02
Extension Wire
.551 inch or 14mm
Power
6
18
3
17
WEL-R8U08
5
WEL-R7U06
*Data Comm.
2
12V DC
*Data Comm.
4
IGT
12V DC
16
1
**MDB
15
WEL-R7U02
AMP 172332-1
**ccTalk 12V DC
CU-R961-1
Power
CU-R961-1
12V DC
Extension Wire
1
2
3
4
5
6
7
8
9
ID003
16
**MDB
P70/77/85
12V DC
15
WEL-R7U02
Extension Wire for WEL-R7U02
Extension Wire for WEL-R7U02
Extension Wire for WEL-R7U02
Extension Wire for WEL-R7U02
Extension Wire for WEL-R7U02
GBA
CU-R961-1
Power & *Data Comm.
12V DC
12V DC
12V DC
12V DC
12V DC
12V DC
Extension Wire
Pulse
RS232
ID003
**ccTalk
RS232
Page
Used Voltage
12V DC
Harness No.
Interface
Pulse
Usage
K
Model
Usage
Table 5.
Used
Interface Voltage
2464 22 AWG 6C CABLE
202
202
202
202
202
202
5-1. Harness Application
www.ictgroup.com.tw
4
1
.551 inch or 14mm
www.igrotechnics.ru
17
D-SUB 9F TOP VIEW
5 4 3 2 1
9 8 7 6
C3
D-SUB(F)
12V DC
12V DC
RS232
ID003
Pin 1- BLUE.......................Ground
Pin 2- WHITE.........Download VCC
Pin 3- BLACK..........................RX1
Pin 4- PURPLE........................TX1
Used Voltage
1
2
3
4
5
Usage
TMT 2*4 BACK VIEW
2 4 6 8
1 3 5 7
2464 22AWG 4C CABLE
WEL-R7U06
*Data Comm.
*Data Comm.
1
2
3
4
5
6
TMT 2*3
TMT 2*4
Pin 1- BLUE.......................Ground
Pin 6- WHITE.........Download VCC
Pin 7- BLACK..........................RX1
Pin 8- PURPLE........................TX1
1
2
3
4
5
6
7
8
PIN 1- RED...................12VDC HOT (POWER)
PIN 2- ORANGE.......................Ground (Power)
PIN 3- YELLOW..................................INHIBIT+
PIN 4- GREEN.....................................INHIBITPIN 5- BLUE..................CREDIT RELAY (N.O.)
PIN 6- PURPLE......CREDIT RELAY (Common)
Usage
TMT 2*3 BACK VIEW
2 4 6
1 3 5
2464 22AWG 6C CABLE
WEL-R7U02
Power & *Data Comm.
Power
Power
Power
Power & *Data Comm.
Power & *Data Comm.
PIN 1- YELLOW...................................INHIBIT+
PIN 2- GREEN......................................INHIBITPIN 5- RED....................12VDC HOT (POWER)
PIN 7- BLUE...................CREDIT RELAY (N.O.)
PIN 8- PURPLE.......CREDIT RELAY (Common)
PIN 9- ORANGE........................Ground (Power)
Interface
AMP 172340-1 BACK VIEW
.165inch or 4.2mm
8
7
+AMP
5
6
9
2
3
J2
16
C2
AMP 172340-1
12V DC
12V DC
12V DC
12V DC
12V DC
12V DC
Pulse
RS232
GBA
ID003
**ccTalk
**MDB
DC12V
C1
www.ictgroup.com.tw
#WEL-R7U02
J3
1
2
3
4
5
6
7
8
9
Used Voltage
Interface
P Series
P Series
Figure 11.
Figure 12.
ICT PROTOCOL
#WEL-R7U06
www.ictgroup.com.tw
www.ictgroup.com.tw
1
2
3
4
5
6
18
www.igrotechnics.ru
19
3
5
6
7
9 11 13 15
8 10 12 14 16
TMT 2*8 BACK VIEW
4
1
TMT 2*8
CN2
PIN 9- RED
PIN 10- ORANGE
PIN 13- YELLOW
PIN 14- GREEN
PIN 15- BLUE
PIN 16- PURPLE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
12V DC
Used Voltage
PIN 1- PURPLE.......+12V
PIN 2- GREEN.........GND
P70 For IGT
#WEL-RP703
2
BA
IGT
Interface
TMT 2*3 BACK VIEW
2 4 6
1 3 5
TMT 2*4
1
2
3
4
5
6
7
8
12V DC
GBA
TMT 2*3
Used Voltage
Interface
AMP 172340-1
Power Box
PIN 1- BROWN
PIN 2- BLACK
PIN 5- RED
PIN 6- ORANGE
XH-B8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
9
WEL-RP703
9
6
3
4
1
8
7
+AMP
5
2
.551 inch or 14mm
PIN 1- BLUE
PIN 2- PURPLE
PIN 3- YELLOW
PIN 5- GREEN
PIN 7- BROWN
PIN 9- BLACK
BLUE..............RXD
PURPLE........+12V
RED................TXD
GREEN..........GND
YELLOW........GND
AMP 172340-1 BACK VIEW
.165inch or 4.2mm
IGT Signal
System
Usage
PIN 1- YELLOW.....GND
PIN 7- BLUE...........RXD
PIN 8- RED.............TXD
*Data Comm.
TMT 2*4 BACK VIEW
2 4 6 8
1 3 5 7
2464 22AWG 6C CABLE
WEL-R8U08
*Data Comm.
Usage
P Series
P Series
Figure 13.
Figure 14.
GBA TO RS-232
#WEL-R8U08
www.ictgroup.com.tw
www.ictgroup.com.tw
20
BLACK.....GND
RED........+12V
PIN 1- YELLOW........INHPIN 2- BROWN......Vend+
PIN 4- GREEN........VendPIN 5- ORANGE.......INH+
WEL-R061
Power
2464 22 AWG 2C CABLE
#WEL-R061
202
1
2
3
4
5
6
MOLEX 7066G 6P
FS2
12V DC
Used Voltage
700B 110V
202
SPIN IGT
IGT
Interface
WEL-033-1
CN3
Dimensions .551 Part NO: 172161-1
CAP
A.M.P
FS1
PIN 1- BROWN........Vend+
PIN 2- GREEN..........VendPIN 3- ORANGE........INH+
PIN 5- YELLOW..........INHPIN 7- BLACK............GND
PIN 9- RED................+12V
1
2
3
4
5
6
7
8
9
Usage
P Series
P Series
Figure 15.
5-1-1. I/O Circuit
Pulse Interface
BA Status
Inhibit
Enable
www.igrotechnics.ru
figure 16.
+5VDC
+5VDC~+12VDC
4K7
Credit_Relay_NO
Credit O/P
Credit_Relay_COM
Bill Acceptor
Customer Side
+5VDC
+5VDC~+12VDC
Inhibit I/P
1K
Inhibit+
InhibitHi"TR ON
Lo"TR OFF
TR
Bill Acceptor
Customer Side
DIP SW Setting Control Signal
Inhibit
Active
Low
Low
High
High
Inhibit
Active
Low
High
High
Low
21
www.ictgroup.com.tw
P Series
P Series
ccTalk Interface
Figure 17.
VEND
TXD
ICT Protocol, GBA and ID003 Interface
+5VDC
+5VDC
Money-Control
System
+5VDC
TXD
TXD
RXD
Bill Acceptor
Bill Acceptor (Plug-in Board)
1K
Customer Side
Customer Side
+5VDC
VEND
+5VDC
figure 18.
Money-Control
System
RXD
RXD
TXD
Hi"TR ON
Lo"TR OFF
RXD
TR
Bill Acceptor (Plug-in Board)
www.ictgroup.com.tw
Customer Side
Bill Acceptor
www.igrotechnics.ru
22
Customer Side
23
www.ictgroup.com.tw
P Series
P Series
MDB Interface
Figure 19.
IGT Interface
figure 20.
+5VDC
+5VDC
+5VDC~+12VDC
+5VDC~+12VDC
TXD
1
8
2
7
3
6
4
5
Bill Acceptor (Plug-in Board)
MDB_MASTER_RXD
+5VDC
1K
4K7
VEND+
VEND-
METER
Bill Acceptor
Customer Side
+5VDC
+5VDC
RXD
Customer Side
+5VDC~+12VDC
+5VDC~+12VDC
8
1
7
2
6
3
5
4
Bill Acceptor (Plug-in Board)
MDB_MASTER_TXD
1K
1K
Inhibit
INH+
HiZTR ON
LoZTR OFF
INH-
TR
Hi"TR ON
Lo"TR OFF
TR
Customer Side
Bill Acceptor
Customer Side
+5VDC
1K
Inhibit
INH+
+5VAC~+12VAC
INH-
Bill Acceptor
www.ictgroup.com.tw
www.igrotechnics.ru
24
25
Customer Side
www.ictgroup.com.tw
P Series
P Series
5-2. DIP Switch Setting
5-3. Software Download and Upgrade
The serial DIP switches which are located on the side of P series
(as figure 21). According to different currencies and credit output
format which are used by users, DIP switch settings could be varied
to fit users' needs. Besides, there's also a serial DIP switches at the
bottom of P series for interface settings (as figure 22).
To download and upgrade the software for P series, the programmer
(FP-001) is needed. Please contact ICT to purchase FP-001 and
refer to FP-001 user guide for software download and upgrade
information.
figure 23.
Please refer to “P Series DIP Switch Setting Guide” in the package
for more details.
PH
COM2
5 4
WEL-RF302
9 8
3
2
7
1
6
PC
figure 21.
P series
O
N
Power
FP-001
1 2 3 4 5 6 7 8 9 10
WEL-R7U03
Firmware
PC
WEL-R087
Please turn on Bill Acceptor after connecting.
figure 21.
O1
N
www.ictgroup.com.tw
2 3 4
www.igrotechnics.ru
26
27
www.ictgroup.com.tw
P Series
P Series
7. Troubleshooting
6. Maintenance
Foreign objects on the LED or sensor may cause bill jamming and
decrease acceptance rate. To make sure the bill acceptor always
works smoothly, please clean the internal parts regularly.
Bezel LED Errors
figure 25.
To clean the internal parts:
1. Turn Bill Acceptor off.
2. Open LED Assembly by pushing buttons on both sides.
3. Use a soft, dry cloth or towel to clean the bill path and sensors.
P70
P77 (Down Stacker)
P77 (Up Stacker)
P85
Buttons
Table 6.
LED
Flashes
figure 24.
Maintenance Notice
(Any improper maintenance will result invalid warranty.)
Recommended
Alcohol
DO NOT USE
www.ictgroup.com.tw
Corrective Actions
1
Bill jammed.
Open bill path unit and then remove the
jammed bill.
2
Disable
Inspect for right DIP switch setting.
3
Recognition sensor
module error.
Inspect for foreign objects on sensor or
bill path and clean.
3+1
Purple sensor error.
3+2
Hook sensor error.
Inspect for foreign objects on sensor or
bill path and clean.
Inspect for foreign objects on security
hook and clean.
3+4
Fish sensor error.
Inspect for foreign objects on sensor or
bill path and clean.
4
A stringing attempt has
detected.
Inspect for foreign objects on sensor or
bill path and clean.
6
Stacker error or
stacker full.
Inspect for foreign objects on stacker
and clean or empty the bill box.
7
Motor error.
Inspect for foreign objects on bill path
and clean.
Mild, non-abrasive, soap water.
Mild, non-abrasive, soap water.
DO NOT USE
Status
Organic solvent , Alcohol, Volatility liquid.
If the error can not be solved after corrective actions or happen
Ifagain,
the error
cancontact
not be solved
corrective
actions or happen
please
ICT forafter
technical
support.
again, please contact ICT for technical support.
www.igrotechnics.ru
Organic solvent , Alcohol, Volatility liquid
28
29
www.ictgroup.com.tw
Taiwan
International Currency Technologies Corporation
Ji-Hong Building, No 24, Alley 38, Lane 91, Nei-hu Rd., Sec. 1, Taipei, Taiwan, R.O.C.
Tel: 886-2-2797-1238 ‧ Fax: 886-2-2797-1634
sales@ictgroup.com.tw (For Sales)
rma@ictgroup.com.tw (For Customer Service)
Website: www.ictgroup.com.tw
www.igrotechnics.ru

Similar documents