Bill acceptor ICT P70 P77
Transcription
Bill acceptor ICT P70 P77
P70/P5 series Bill Acceptor Installation Guide P77/P5 www.igrotechnics.ru 2005 International Currency Technologies Corporation V. 5.0 Part Number : H4814D-R P85/P5 International Currency Technologies Corp. Contents 1. Introduction ...............................................................................2 1-1. Overview.............................................................................2 1-2. Features .............................................................................2 2. Specifications ............................................................................3 General ......................................................................................3 Electrical ....................................................................................3 Use of Materials Limitations International Currency Technologies Corporation (ICT) all rights reserved. All materials contained are the copyrighted property of ICT. All trademarks, service marks, and trade names are proprietary to ICT. ICT reserves the right at all times to disclose or to modify any information as ICT deems necessary to satisfy any applicable law, regulation, legal process or governmental request, or to edit, refuse to post or to remove any information or materials, in whole or in part, in ICT's sole discretion. Mechanical ................................................................................4 3. Packing List ...............................................................................4 4. Dimension .................................................................................5 4-1. Bezel Application ..............................................................10 5. Installation ...............................................................................14 5-1. Harness Application .........................................................14 5-1-1. I/O Circuit ...............................................................21 5-2. DIP Switch Setting ...........................................................26 5-3. Software Download and Upgrade ....................................27 6. Maintenance ............................................................................28 7. Troubleshooting .......................................................................29 www.igrotechnics.ru 1 www.ictgroup.com.tw P Series P Series 2. Specifications 1. Introduction 1-1. Overview General P series is a new generation of bill acceptor designed by ICT which features high-security with acceptance rate up to 96%. In addition, multiple bezel and bill box selections offer users the most convenient and complete services. Acceptance Rate 96% or greater *Note: The Incomplete bills such as extremely dirty, wet, broken, or wrinkled ones are excluded! Bill Insertion Four way acceptable Transaction Time Approx. 3 seconds to stack Approx. 2 seconds without stacking Interface Four ways bill insertion acceptance. Pulse, ICT Protocol, ccTalk,ID003, MDB, GPT, IGT High acceptance rate. *Combination is possible. Ex. Pulse+MDB. 1-2. Features Multiple bezel selections. Stacker with capacity of 200 or 500 bills are available. Installation: Indoor use only!! High security by protective mechanism. Electrical www.ictgroup.com.tw Power Source 12V DC (11.4~12.6V DC) Power Consumption Standby: 0.21A~0.35A (2.5W~4.2W) Operation Current: 2A, 24W Motor Lock: 2.2A, 26.4W Operation Environment Operation Temperature: 0°C~55°C Storage Temperature: -20°C~70°C Humidity: 30%~85%RH (no condensation) www.igrotechnics.ru 2 3 www.ictgroup.com.tw P Series P Series 4. Dimension P70 Weight 0.65~0.75kg (Stackerless) 1.5 ~1.65kg (With Stacker) Bill Accepted Width P70-P5 : 62mm~70mm P77-P2/P5: 66mm~77mm P85-P5 : 68mm~85mm 39.8[1.57] P2: Approx. 200 bills P5: Approx. 500 bills 82.3[3.24] 12.4[0.49] Bill Box Capacity 5.3[0.21] 14.2[0.56] P70/P5 : Refer to page. 5 P77/P2/P5: Refer to page. 6 P85/P5 : Refer to page. 8 114.9[4.53] 102.4[4.03] 84.9[3.34] 120.8[4.75] 89.6[3.53] 53.4[2.10] Outline Dimension figure 1. 93.0[3.66] 84.0[3.31] 51.0[2.01] 134.0[5.28] 117.0[4.61] Mechanical Unit:mm[inch] P70-P5 Harness: Refer to 5-1 P Series Installation Guide P Series DIP Switch Setting Guide 83.0[3.27] www.ictgroup.com.tw www.igrotechnics.ru 4 39.8[1.57] 95.9[3.78] Accessory 30.0[1.18] 17.5[0.69] 120.3[4.74] 80.9[3.19] 44.9[1.77] 13.7[0.54] Bill Acceptor 169.7[6.68] 287.3[11.31] Main 134.0[5.28] 125.5[4.94] 120.3[4.74] 3. Packing List 13.7[0.54] 8.5[0.33] figure 2. 93.0[3.66] 84.0[3.31] 51.0[2.01] Unit:mm[inch] 5 www.ictgroup.com.tw P Series P Series P77 (Down Stacker Type) figure 3. 5.3 [.209] figure 5. 100.0[3.937] 84.0[3.307] 50.8[2.000] 128.4[5.055] 108.4[4.268] 90.9[3.579] Unit:mm[inch] figure 4. 175.00[6.890](500P) www.igrotechnics.ru 6 120.5[4.744] 4.00[.157] 17.50[.689] 37.50[1.476] Unit:mm[inch] Unit:mm[inch] www.ictgroup.com.tw 73.53[2.895] 120.50[4.744] 134.00[5.276] 124.50[4.902] 73.53[2.895] 36.17[1.424] 9.50[.374] 12.70 [0.50] 278.10[10.949] 28.30[1.114] 80.10[3.154] 127.00[5.000](200P) 175.00[6.890] (500P) 50.80[2.000] 84.00[3.307] 85.00[3.346] 100.00[3.937] 92.00[3.622] 73.5[2.895] figure 6. 92.00[3.622] 127.00[5.000](200P) 80.10[3.154] 28.30[1.114] 66.53[2.619] 29.17[1.149] 134.00[5.276] 119.70 [4.71] 276.60[10.890] 125.50[4.941] 134.00[5.276] 4.00[.157] P77-P2/P5 (Up Stacker Type) 13.50[.531] 36.17[1.424] 17.50[.689] Unit:mm[inch] 8.50[.335] 125.50[4.941] 134.00[5.276] 37.50[1.476] 8.50[.335] 100.00[3.937] 85.00[3.346] 84.00[3.307] 50.80[2.000] 124.50[4.902] 66.53[2.619] 29.17[1.148] 9.50[.374] P77-P2/P5 (Down Stacker Type) 36.2[1.424] 29.5[1.161] 13.5 [0.531] 81.5[3.209] 117.0[4.606] 134.0[5.276] 81.50[3.209] 23.70[.933] 120.50[ 4.744] 104.83[4.127] 67.47[2.656] 13.50[.531] 117.00[4.606] 134.00[5.276] 23.0[.906] 128.40[5.055] 108.40[4.268] 90.90[3.579] 28.80[1.134] 5.30[.209] 100.00[3.937] 84.00[3.307] 50.80[2.000] P77 (Up Stacker Type) 7 www.ictgroup.com.tw P Series 84.0 [3.31] 50.8 [2.00] 14.0 [0.55] 8.5 [0.33] 14.0 [0.55] 106.0 [4.18] 117.0 [4.61] 134.0 [5.28] 134.0 [5.28] 106.0 [4.18] 54.9 [2.16] 34.1 [1.34] figure 7. 50.8 [2.00] 92.0 [3.62] 100.0 [3.94] 107.8 [4.25] To install the bill acceptor on your VMC, please be aware of the dimension as below: [ L ] : Longer than the maximum length of accepted bills. [ L1 ] : Bill box capacity depth. * [ L/2 ] has to be longer than 70mm to open upper base. 13.5 [0.53] 27.2 [1.07] 87.2 [3.44] 5.3 [0.21] Figure.9 Unit:mm[inch] P85-P5 L/2 P85 P Series figure 8. 8.50[.335] 31.18[1.227] 80.10[3.154] 28.35[1.116] L 134.00[5.276] 120.00[4.724] 65.11[2.563] 31.03[1.222] 14.00[.551] 17.50[.689] 4.00[.157] 174.78[6.881] L1 275.75[10.856] 125.50[4.941] 134.00[5.276] 125.00[4.921] 65.11[2.563] 14.00[.551] 9.00[.354] L 100.0[3.937] 92.0[3.622] 84.0[3.307] 50.8[2.000] 99.00[3.898] www.igrotechnics.ru Unit:mm[inch] www.ictgroup.com.tw 8 9 www.ictgroup.com.tw P Series P Series 4-1. Bezel Application P70 Bill Accepted Width: 62mm~70mm Table 1. Figure P77 Bill Accepted Width: 66mm~77mm Table 2. Figure Name Break Proof Bezel Module(Green) Break Proof Bezel Module(Green-Russia) Name Metal Bezel Part Number 3RBA-FAC23XXX 3RBA-FAC24XXX Part Number 3RBA-STP07XXX Mounting Kits Application V V Mounting Kits Application Tricolor Marquee Bezel Tricolor Marquee Bezel (Down Stacker) (Up Stacker) 3RBA-FAC22XXX 3RBA-FAC39XXX V V Figure www.ictgroup.com.tw Name Self-color Marquee Bezel Green Bezel Module (Non Step Style) Green Bezel Module (Step Style) Part Number 3RBA-FAC22XXX 3RBA-FAC25XXX 3RBA-FAC26XXX Mounting Kits Application V V V www.igrotechnics.ru 10 11 www.ictgroup.com.tw P Series P Series P77 Bill Accepted Width: 66mm~77mm Table 3. P85 Bill Accepted Width: 68mm~85mm Table 4. Figure Figure Name Angular Snout Bezel Marquee Break Proof Bezel (Aluminum) S Type Marquee Bezel Part Number 3RBA-FAC29XXX 3RBA-FAC40XXX 3RBA-FAC43XXX Mounting Kits Application Name Bezel Module (Green) Part Number 3RBA-FAC27XXX Mounting Kits Application V Figure Name Horizontal Bezel Module Part Number 3RBA-FAC21XXX Mounting Kits Application www.ictgroup.com.tw www.igrotechnics.ru 12 13 www.ictgroup.com.tw P Series P Series 5. Installation Figure 10. WEL-R7U06 17 Extension Wire CU-R961-1 15 Power & *Data Comm. WEL-R7U02 16 Extension Wire CU-R961-1 15 Power & *Data Comm. WEL-R7U02 16 *Data Comm. WEL-RP703 19 Power WEL-R061 20 * Data Comm. : Data Communication. ** Plug-in Board: (1) ccTalk: 5RBG-AA248M2-04-2 (2) MDB : (New) 5RBG-AA313NA0-01 (Old) 5RBG-AA266NA0-01 www.ictgroup.com.tw DC 12V #CU-R961-1 www.igrotechnics.ru 14 +AMP 15 .165inch or 4.2mm *Data Comm. AMP 172332-1 BACK VIEW 16 9 WEL-R7U02 8 15 Power 7 16 CU-R961-1 PIN 1- YELLOW...........................INHIBIT+ PIN 2- GREEN..............................INHIBITPIN 5- RED...............+12VDC(POWER-IN) PIN 7- BLUE...............CREOIT-RELAY-NO PIN 8- PURPLE.......CREDIT-RELAY-COM PIN 9- ORANGE.............GND(POWER-IN) WEL-R7U02 Extension Wire .551 inch or 14mm Power 6 18 3 17 WEL-R8U08 5 WEL-R7U06 *Data Comm. 2 12V DC *Data Comm. 4 IGT 12V DC 16 1 **MDB 15 WEL-R7U02 AMP 172332-1 **ccTalk 12V DC CU-R961-1 Power CU-R961-1 12V DC Extension Wire 1 2 3 4 5 6 7 8 9 ID003 16 **MDB P70/77/85 12V DC 15 WEL-R7U02 Extension Wire for WEL-R7U02 Extension Wire for WEL-R7U02 Extension Wire for WEL-R7U02 Extension Wire for WEL-R7U02 Extension Wire for WEL-R7U02 GBA CU-R961-1 Power & *Data Comm. 12V DC 12V DC 12V DC 12V DC 12V DC 12V DC Extension Wire Pulse RS232 ID003 **ccTalk RS232 Page Used Voltage 12V DC Harness No. Interface Pulse Usage K Model Usage Table 5. Used Interface Voltage 2464 22 AWG 6C CABLE 202 202 202 202 202 202 5-1. Harness Application www.ictgroup.com.tw 4 1 .551 inch or 14mm www.igrotechnics.ru 17 D-SUB 9F TOP VIEW 5 4 3 2 1 9 8 7 6 C3 D-SUB(F) 12V DC 12V DC RS232 ID003 Pin 1- BLUE.......................Ground Pin 2- WHITE.........Download VCC Pin 3- BLACK..........................RX1 Pin 4- PURPLE........................TX1 Used Voltage 1 2 3 4 5 Usage TMT 2*4 BACK VIEW 2 4 6 8 1 3 5 7 2464 22AWG 4C CABLE WEL-R7U06 *Data Comm. *Data Comm. 1 2 3 4 5 6 TMT 2*3 TMT 2*4 Pin 1- BLUE.......................Ground Pin 6- WHITE.........Download VCC Pin 7- BLACK..........................RX1 Pin 8- PURPLE........................TX1 1 2 3 4 5 6 7 8 PIN 1- RED...................12VDC HOT (POWER) PIN 2- ORANGE.......................Ground (Power) PIN 3- YELLOW..................................INHIBIT+ PIN 4- GREEN.....................................INHIBITPIN 5- BLUE..................CREDIT RELAY (N.O.) PIN 6- PURPLE......CREDIT RELAY (Common) Usage TMT 2*3 BACK VIEW 2 4 6 1 3 5 2464 22AWG 6C CABLE WEL-R7U02 Power & *Data Comm. Power Power Power Power & *Data Comm. Power & *Data Comm. PIN 1- YELLOW...................................INHIBIT+ PIN 2- GREEN......................................INHIBITPIN 5- RED....................12VDC HOT (POWER) PIN 7- BLUE...................CREDIT RELAY (N.O.) PIN 8- PURPLE.......CREDIT RELAY (Common) PIN 9- ORANGE........................Ground (Power) Interface AMP 172340-1 BACK VIEW .165inch or 4.2mm 8 7 +AMP 5 6 9 2 3 J2 16 C2 AMP 172340-1 12V DC 12V DC 12V DC 12V DC 12V DC 12V DC Pulse RS232 GBA ID003 **ccTalk **MDB DC12V C1 www.ictgroup.com.tw #WEL-R7U02 J3 1 2 3 4 5 6 7 8 9 Used Voltage Interface P Series P Series Figure 11. Figure 12. ICT PROTOCOL #WEL-R7U06 www.ictgroup.com.tw www.ictgroup.com.tw 1 2 3 4 5 6 18 www.igrotechnics.ru 19 3 5 6 7 9 11 13 15 8 10 12 14 16 TMT 2*8 BACK VIEW 4 1 TMT 2*8 CN2 PIN 9- RED PIN 10- ORANGE PIN 13- YELLOW PIN 14- GREEN PIN 15- BLUE PIN 16- PURPLE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 12V DC Used Voltage PIN 1- PURPLE.......+12V PIN 2- GREEN.........GND P70 For IGT #WEL-RP703 2 BA IGT Interface TMT 2*3 BACK VIEW 2 4 6 1 3 5 TMT 2*4 1 2 3 4 5 6 7 8 12V DC GBA TMT 2*3 Used Voltage Interface AMP 172340-1 Power Box PIN 1- BROWN PIN 2- BLACK PIN 5- RED PIN 6- ORANGE XH-B8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 WEL-RP703 9 6 3 4 1 8 7 +AMP 5 2 .551 inch or 14mm PIN 1- BLUE PIN 2- PURPLE PIN 3- YELLOW PIN 5- GREEN PIN 7- BROWN PIN 9- BLACK BLUE..............RXD PURPLE........+12V RED................TXD GREEN..........GND YELLOW........GND AMP 172340-1 BACK VIEW .165inch or 4.2mm IGT Signal System Usage PIN 1- YELLOW.....GND PIN 7- BLUE...........RXD PIN 8- RED.............TXD *Data Comm. TMT 2*4 BACK VIEW 2 4 6 8 1 3 5 7 2464 22AWG 6C CABLE WEL-R8U08 *Data Comm. Usage P Series P Series Figure 13. Figure 14. GBA TO RS-232 #WEL-R8U08 www.ictgroup.com.tw www.ictgroup.com.tw 20 BLACK.....GND RED........+12V PIN 1- YELLOW........INHPIN 2- BROWN......Vend+ PIN 4- GREEN........VendPIN 5- ORANGE.......INH+ WEL-R061 Power 2464 22 AWG 2C CABLE #WEL-R061 202 1 2 3 4 5 6 MOLEX 7066G 6P FS2 12V DC Used Voltage 700B 110V 202 SPIN IGT IGT Interface WEL-033-1 CN3 Dimensions .551 Part NO: 172161-1 CAP A.M.P FS1 PIN 1- BROWN........Vend+ PIN 2- GREEN..........VendPIN 3- ORANGE........INH+ PIN 5- YELLOW..........INHPIN 7- BLACK............GND PIN 9- RED................+12V 1 2 3 4 5 6 7 8 9 Usage P Series P Series Figure 15. 5-1-1. I/O Circuit Pulse Interface BA Status Inhibit Enable www.igrotechnics.ru figure 16. +5VDC +5VDC~+12VDC 4K7 Credit_Relay_NO Credit O/P Credit_Relay_COM Bill Acceptor Customer Side +5VDC +5VDC~+12VDC Inhibit I/P 1K Inhibit+ InhibitHi"TR ON Lo"TR OFF TR Bill Acceptor Customer Side DIP SW Setting Control Signal Inhibit Active Low Low High High Inhibit Active Low High High Low 21 www.ictgroup.com.tw P Series P Series ccTalk Interface Figure 17. VEND TXD ICT Protocol, GBA and ID003 Interface +5VDC +5VDC Money-Control System +5VDC TXD TXD RXD Bill Acceptor Bill Acceptor (Plug-in Board) 1K Customer Side Customer Side +5VDC VEND +5VDC figure 18. Money-Control System RXD RXD TXD Hi"TR ON Lo"TR OFF RXD TR Bill Acceptor (Plug-in Board) www.ictgroup.com.tw Customer Side Bill Acceptor www.igrotechnics.ru 22 Customer Side 23 www.ictgroup.com.tw P Series P Series MDB Interface Figure 19. IGT Interface figure 20. +5VDC +5VDC +5VDC~+12VDC +5VDC~+12VDC TXD 1 8 2 7 3 6 4 5 Bill Acceptor (Plug-in Board) MDB_MASTER_RXD +5VDC 1K 4K7 VEND+ VEND- METER Bill Acceptor Customer Side +5VDC +5VDC RXD Customer Side +5VDC~+12VDC +5VDC~+12VDC 8 1 7 2 6 3 5 4 Bill Acceptor (Plug-in Board) MDB_MASTER_TXD 1K 1K Inhibit INH+ HiZTR ON LoZTR OFF INH- TR Hi"TR ON Lo"TR OFF TR Customer Side Bill Acceptor Customer Side +5VDC 1K Inhibit INH+ +5VAC~+12VAC INH- Bill Acceptor www.ictgroup.com.tw www.igrotechnics.ru 24 25 Customer Side www.ictgroup.com.tw P Series P Series 5-2. DIP Switch Setting 5-3. Software Download and Upgrade The serial DIP switches which are located on the side of P series (as figure 21). According to different currencies and credit output format which are used by users, DIP switch settings could be varied to fit users' needs. Besides, there's also a serial DIP switches at the bottom of P series for interface settings (as figure 22). To download and upgrade the software for P series, the programmer (FP-001) is needed. Please contact ICT to purchase FP-001 and refer to FP-001 user guide for software download and upgrade information. figure 23. Please refer to “P Series DIP Switch Setting Guide” in the package for more details. PH COM2 5 4 WEL-RF302 9 8 3 2 7 1 6 PC figure 21. P series O N Power FP-001 1 2 3 4 5 6 7 8 9 10 WEL-R7U03 Firmware PC WEL-R087 Please turn on Bill Acceptor after connecting. figure 21. O1 N www.ictgroup.com.tw 2 3 4 www.igrotechnics.ru 26 27 www.ictgroup.com.tw P Series P Series 7. Troubleshooting 6. Maintenance Foreign objects on the LED or sensor may cause bill jamming and decrease acceptance rate. To make sure the bill acceptor always works smoothly, please clean the internal parts regularly. Bezel LED Errors figure 25. To clean the internal parts: 1. Turn Bill Acceptor off. 2. Open LED Assembly by pushing buttons on both sides. 3. Use a soft, dry cloth or towel to clean the bill path and sensors. P70 P77 (Down Stacker) P77 (Up Stacker) P85 Buttons Table 6. LED Flashes figure 24. Maintenance Notice (Any improper maintenance will result invalid warranty.) Recommended Alcohol DO NOT USE www.ictgroup.com.tw Corrective Actions 1 Bill jammed. Open bill path unit and then remove the jammed bill. 2 Disable Inspect for right DIP switch setting. 3 Recognition sensor module error. Inspect for foreign objects on sensor or bill path and clean. 3+1 Purple sensor error. 3+2 Hook sensor error. Inspect for foreign objects on sensor or bill path and clean. Inspect for foreign objects on security hook and clean. 3+4 Fish sensor error. Inspect for foreign objects on sensor or bill path and clean. 4 A stringing attempt has detected. Inspect for foreign objects on sensor or bill path and clean. 6 Stacker error or stacker full. Inspect for foreign objects on stacker and clean or empty the bill box. 7 Motor error. Inspect for foreign objects on bill path and clean. Mild, non-abrasive, soap water. Mild, non-abrasive, soap water. DO NOT USE Status Organic solvent , Alcohol, Volatility liquid. If the error can not be solved after corrective actions or happen Ifagain, the error cancontact not be solved corrective actions or happen please ICT forafter technical support. again, please contact ICT for technical support. www.igrotechnics.ru Organic solvent , Alcohol, Volatility liquid 28 29 www.ictgroup.com.tw Taiwan International Currency Technologies Corporation Ji-Hong Building, No 24, Alley 38, Lane 91, Nei-hu Rd., Sec. 1, Taipei, Taiwan, R.O.C. Tel: 886-2-2797-1238 ‧ Fax: 886-2-2797-1634 sales@ictgroup.com.tw (For Sales) rma@ictgroup.com.tw (For Customer Service) Website: www.ictgroup.com.tw www.igrotechnics.ru