Great Lakes
Transcription
Great Lakes
Great Lakes Bracket Catalog 2016 Exceptional Quality. 200 Cooper Avenue PO Box 5111 Tonawanda, NY 14151-5111 1.800.828.7626 (U.S. & Canada) 716.871.1161 (Worldwide) Email: bracketsales@greatlakesortho.com www.GreatLakesBrackets.com SMPP580Rev031716 Manufactured by Aditek® Orthodontics Outstanding Value. After years of research and evaluation, Great Lakes is proud to offer a full line of quality fixed appliances that are value priced for practice profitability. We endorsed these brackets specifically for their outstanding value and exceptional quality. The intelligent design, versatility, and maximum reliability of this bracket line meets our stringent standards of excellence to bear our name. Great Lakes is thrilled to now offer orthodontic brackets to our customers worldwide. Please take time to watch our information videos to learn more about the various systems. Our team of bracket specialists are available to answer your questions, and provide free, personalized consultation. James R. Kunkemoeller President and CEO Great Lakes Orthodontics, Ltd. EMPLOYEE OWNED 1 General Information WELCOME Since 1967, Great Lakes has been dedicated to helping customers achieve business success by providing outstanding customer service, technical support, and products guaranteed to be of the highest quality and workmanship. Please let us know how we can partner with you! ORDERING OPTIONS PAYMENT OPTIONS & TERMS When ordering by phone, fax, or email, please be as specific as possible. Include the item number, quantity desired, and descriptive information such as size and color, as appropriate. Orders are processed Monday-Friday during normal business hours. In most cases, routine orders received by 12 p.m.(Eastern Standard Time) are shipped within 24 hours. Payment Options: Credit Cards: We accept MasterCard, Visa, and American Express. Other: Checks, money orders, wire transfers, and eChecks. Payment Terms: Invoices are payable within 30 days of invoice date (some exceptions apply). A $35 fee will be charged for each returned check. (Prices are subject to change.) Phone:1.800.828.7626(U.S. & Canada) 716.871.1161 (Worldwide) • Our phone lines are open Monday-Friday from 8 a.m. to 5 p.m. (Eastern Standard Time). SHIPMENTS • All shipments are F.O.B. Buffalo unless otherwise stated. • Great Lakes will determine the type of carrier for all shipments except when the customer has provided special instructions. We will not accept liability for shipping charges, duty or tax. • An itemized packing list will accompany each order. To ensure proper shipment, compare packing list with items received. If incorrect, Great Lakes must be notified within 10 days of receipt of m erchandise. • If merchandise is damaged during shipping, notification must be made to the carrier within seven days. Retain original damaged packing for carrier evaluation. Great Lakes must then be contacted so that arrangements can be made for a replacement o rder. • Backorders: Backorders that weigh less than 1 lb or are valued under $20.00 will ship at no charge. Customers are responsible for freight charges on backorders that are outside these parameters. Web: www.GreatLakesBrackets.com • For your convenience, Great Lakes products, can be ordered online 24/7. Email: bracketsales@greatlakesortho.com • Please feel free to email us with your order, questions, or concerns. • If paying by credit card, indicate your card number, expiration date, CVV2 security code, and name on the card. FAX: 716.253.6383 • List your phone number and email on your fax order. • If paying by credit card, indicate your card number, expiration date, CVV2 security code, and name on the card. Mail Orders: • Address orders to: Bracket Customer Service Great Lakes Orthodontics, Ltd. 200 Cooper Avenue Tonawanda, NY 14150 • Be sure to include the street address, as carriers will not deliver to a P.O. Box. • List your phone number and email on your order. • If paying by credit card, indicate your card number, expiration date, CVV2 security code, and name on the card. RETURN & CREDIT POLICY To help us quickly process your return: • All returns require a Customer Return Service (CRS) Authorization N umber. • Returned items must be unused and in resalable condition. • Returns must be made within 30 days, upon receipt by customer, to avoid restocking charges. Great Lakes reserves the right to refuse credit on any item returned after 30 days. • Returns after 30 days are subject to a 15% restocking charge unless the item is damaged in shipping or shipped in error. • All products must be returned prepaid and insured at full invoice v alue. MINIMUM ORDER A $30 minimum order is requested. Whenever possible, group your orders to meet the minimum and to help keep your shipping costs lower. DISCOUNTS PROGRAMS Customers who qualify for special discounts, such as students or Advantage Program Members, will automatically receive their standard discount or the sale price, whichever is the best savings. Discount Program for 1st Year Graduates: For a period of one year after graduation, dental school graduates are eligible for a 15% discount on most products, and a 10% discount on most appliance fabrication service from our laboratory (some exclusions apply). Participants can also receive advice on selecting the right products for their practice as well as technical assistance. 2 General Information TABLE OF CONTENTS BRACKET SYSTEMS 4-23 Self Ligating EasyClip+® ..................................................................................... 4-15 BioTru™ Classic ................................................................................ 16-17 Aesthetic BioTru™ Ceramic ......................................................................... 18-19 BioTru™ Sapphire ........................................................................20-21 BioMax® ............................................................................................22-23 ARCHWIRES 24-29 BioTru™ Reverse Curve of Spee..................................................... 25- 26 BioTru™ NiTi..............................................................................24,26-27 BioTru™ Copper ............................................................................... 24, 27 BioTru™ Contour .............................................................................. 24, 27 BioTru™ Retraction.......................................................................... 25, 28 BioTru™ Beta Titanium .................................................................... 24, 29 BioTru™ Stainless............................................................................ 25, 29 AUXILIARIES 30-32 Buccal Tubes.................................................................................... 30-31 Hooks & Stops ....................................................................................... 32 NiTi Springs............................................................................................ 32 ACCESSORIES 33-35 Ligatures ................................................................................................ 33 Adhesives......................................................................................... 34-35 Bite Ramps............................................................................................. 35 To our valued customers: Great Lakes has made every reasonable effort to ensure the accuracy of this catalog, including product descriptions and depiction. However, errors do occur. Great Lakes reserves the right to correct any errors, inaccuracies, or omissions as appropriate. Brackets are not for sale in Canada. Prices are subject to change without notice. ISO 13485: 2003 Registered 3 Extreme Versatility. Exceptional Control. The EasyClip+® Systems can be used as fully passive, fully interactive, or a combination of both. This hybrid approach enables you to use both passive and interactive brackets, offering a variety of treatment options. ^ĞůĨͲ>ŝŐĂƟŶŐƌĂĐŬĞƚ^LJƐƚĞŵƐ Intelligently designed, EasyClip+ is engineered for comfort, easy placement, and secure bonding. ONE SYSTEM Multiple Applications • Improved Clinical Management • Faster Results Defined and spacious tie-wing undercuts if ligation is needed } Rounded corners provide maximum patient comfort Mesial to Distal slot clip coverage offers total rotational control An ultra low profile provides maximum patient comfort. Passive (Flat Tab) Open mini twin design allows optimal patient hygiene Planar thermal NiTi clip will not deform or age for the life of treatment V channel for easy positioning reference Dual lock clip stays shut - locks securely Interactive (Curved Tab) Mushroom-shaped pylons create undercuts for superior bond strength Compound contour base for easy, accurate placement KEY ADVANTAGES • Innovative chairside system reduces time and costs associated with changing archwires and appliances Easy to open/close–no special instruments required. Lever action opening of the clip offsets forces for patient comfort. To Close: Use a utility plier, tweezer, or fingertip. Audible ‘Click’ when closing the clip. Opens easily using an explorer. • Longer time intervals between visits • Well-defined Archwire Sequencing Protocols • A complete archwire system with ‘Force Modules’ specifically calibrated for Self-Ligating Brackets • Physiologically and mechanically advantageous ‘Light Forces’ AVAILABLE PRESCRIPTIONS • Damon® Low Torque • Damon® Standard Torque • Damon® High Torque • ROTH • MBT Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation. 4 Brackets-Self-Ligating PASSIVE DAMON STANDARD PRESCRIPTION Slot .022" x .028" Kit variations: length torque angle Off In-out Replacement .022" x .028" Slot quantity Reference 05.21.0090 Hooks on 3. 4 & 5 20 brackets 74.02.910SP - Hooks on 3 .022 3 mm -11° 2° 2° 0.25 mm 3 mm -11° 2° 2° 0.25 mm 3 mm 7° 5° 4° 0.25 mm 2.7 mm 6° 9° 0° 0.65 mm 2.9 mm 15° 5° 0° 0.50 mm 2.9 mm 15° 5° 0° 0.50 mm 2.7 mm 6° 9° 0° 0.65 mm 3 mm 7° 5° 4° 0.25 mm 3 mm -11° 2° 2° 0.25mm 3 mm -11° 2° 2° 0.25 mm 05.21.1214 05.21.1214 05.21.1213 05.21.1212 05.21.1211 05.21.1221 05.21.1222 05.21.1223 05.21.1224 05.21.1224 5 5 5 5 5 5 5 5 5 5 5 43 211 234 5 15 1413 121121 222324 25 Upper Lower length torque angle Off In-out Replacement .022" x .028" Slot quantity 45 4443 424131 323334 35 5 43 211 234 5 3 mm 3 mm 2.9 mm 2.7 mm 2.7 mm 2.7 mm 2.7 mm 2.9 mm 3 mm 3 mm -17° -12° 7° -3° -3° -3° -3° 7° -12° -17° 4° 4° 5° 4° 2° 2° 4° 5° 4° 4° 4° 4° 2° 0° 0° 0° 0° 2° 4° 4° 0.15 mm 0.15 mm 0.20 mm 0.45 mm 0.45 mm 0.45 mm 0.45 mm 0.20 mm 0.15 mm 0.15 mm 05.21.1245 5 05.21.1244 5 05.21.1243 5 05.21.1242 5 05.21.1241 5 05.21.1231 5 05.21.1232 5 05.21.1233 5 05.21.1234 5 05.21.1235 5 2.7 mm -5° 9° 0° 0.65 mm 2.9 mm 2° 5° 0° 0.50 mm 2.9 mm 2° 5° 0° 0.50 mm 2.7 mm -5° 9° 0° 0.65 mm 3 mm -9° 5° 4° 0.25 mm 3 mm -11° 2° 2° 0.25mm 3 mm -11° 2° 2° 0.25 mm DAMON LOW TORQUE PRESCRIPTION Slot .022" x .028" Kit variations: length torque angle Off In-out Replacement .022" x .028" Slot quantity Reference 05.21.1090 Hooks on 3. 4 & 5 20 brackets 74.02.910LP - Hooks on 3 .022 3 mm -11° 2° 2° 0.25 mm 3 mm -11° 2° 2° 0.25 mm 3 mm -9° 5° 4° 0.25 mm 74.02.814PS 74.02.814PS 05.21.1013 05.21.1012 05.21.1011 05.21.1021 05.21.1022 05.21.1023 74.02.824PS 74.02.824PS 5 5 5 5 5 5 5 5 5 5 5 43 211 234 5 15 1413 121121 222324 25 Upper Lower length torque angle Off In-out Replacement .022" x .028" Slot quantity 45 4443 424131 323334 35 5 43 211 234 5 3 mm 3 mm 2.9 mm 2.7 mm 2.7 mm 2.7 mm 2.7 mm 2.9 mm 3 mm 3 mm -17° -12° 0° -11° -11° -11° -11° 0° -12° -17° 4° 4° 5° 4° 2° 2° 4° 5° 4° 4° 4° 4° 2° 0° 0° 0° 0° 2° 4° 4° 0.15 mm 0.15 mm 0.20 mm 0.45 mm 0.45 mm 0.45 mm 0.45 mm 0.20 mm 0.15 mm 0.15 mm 74.02.845PS 5 74.02.844PS 5 05.21.1043 5 05.21.1042 5 05.21.1041 5 05.21.1031 5 05.21.1032 5 05.21.1033 5 74.02.834PS 5 Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation. 5 74.02.835PS 5 Brackets-Self-Ligating PASSIVE DAMON HIGH TORQUE PRESCRIPTION Kit variations: length torque angle Off In-out Replacement .022" x .028" Slot quantity 74.02.910AP/BP/CP - Hooks on 3 .022 3 mm -11° 2° 2° 0.25 mm 3 mm -11° 2° 2° 0.25mm 3 mm 11° 5° 4° 0.25 mm 2.7 mm 13° 9° 0° 0.65 mm 2.9 mm 22° 5° 0° 0.50 mm 2.9 mm 22° 5° - 0° 0.50 mm 2.7 mm 13° 9° 0° 0.65 mm 3 mm 11° 5° 4° 0.25 mm 3 mm -11° 2° 2° 0.25 mm 3 mm -11° 2° 2° 0.25 mm 74.02.814PS 74.02.814PS 05.21.1113 05.21.1112 05.21.1111 05.21.1121 05.21.1122 05.21.1123 74.02.824PS 74.02.824PS 5 5 5 5 5 5 5 5 5 5 5 43 211 234 5 15 1413 121121 222324 25 Upper Lower length torque angle Off In-out Replacement .022" x .028" Slot quantity 45 4443 424131 323334 35 5 43 211 234 5 3 mm 3 mm 2.9 mm 2.7 mm 2.7 mm 2.7 mm 2.7 mm 2.9 mm 3 mm 3 mm -17° -5° 13° 0° 0° 0° 0° 13° -5° -17° 4° 4° 5° 0° 0° 0° 0° 5° 4° 4° 4° 4° 2° 0° 0° 0° 0° 2° 4° 4° 0.15 mm 0.15 mm 0.20 mm 0.45 mm 0.45 mm 0.45 mm 0.45 mm 0.20 mm 0.15 mm 0. 15 mm 74.02.845PS 5 05.21.1144 5 05.21.1143 5 74.02.841PH 5 74.02.841PH 5 74.02.841PH 5 74.02.841PH 5 05.21.1133 5 05.21.1134 5 74.02.835PS 5 2.7 mm 8° 9° 0° 0.65 mm 2.9 mm 12° 5° 0° 0.50 mm 2.9 mm 12° 5° - 0° 0.50 mm 2.7 mm 8° 9° 0° 0.65 mm 3 mm 0° 11° 4° 0.25 mm 3 mm -7° 0° 2° 0.25mm 3 mm -7° 0° 2° 0.25 mm ROTH PRESCRIPTION Slot .022" x .028" Kit variations: length torque angle Off In-out Replacement .022" x .028" Slot quantity Reference 05.21.0390 Hooks on 3. 4 & 5 20 brackets 74.32.910P - Hooks on 3 .022 3 mm -7° 0° 2° 0.25 mm 3 mm -7° 0° 2° 0.25 mm 3 mm 0° 11° 4° 0.25 mm 05.21.0314 05.21.0314 05.21.0313 05.21.0312 05.21.0311 05.21.0321 05.21.0322 05.21.0323 05.21.0324 05.21.0324 5 5 5 5 5 5 5 5 5 5 5 43 211 234 5 15 1413 121121 222324 25 Upper Lower length torque angle Off In-out Replacement .022" x .028" Slot quantity 45 4443 424131 323334 35 5 43 211 234 5 3 mm 3 mm 2.9 mm 2.7 mm 2.7 mm 2.7 mm 2.7 mm 2.9 mm 3 mm 3 mm -22° -17° -11° 0° 0° 0° 0° -11° -17° -22° 0° 0° 5° 0° 0° 0° 0° 5° 0° 0° 4° 4° 2° 0° 0° 0° 0° 2° 4° 4° 0.15 mm 0.15 mm 0.20 mm 0.45 mm 0.45 mm 0.45 mm 0.45 mm 0.20 mm 0.15 mm 0.15 mm 05.21.0345 5 05.21.0344 5 05.21.0343 5 05.21.0341 5 05.21.0341 5 05.21.0341 5 05.21.0341 5 05.21.0333 5 05.21.0334 5 Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation. 6 05.21.0335 5 Brackets-^ĞůĨͲ>ŝŐĂƟŶŐ PASSIVE MBT PRESCRIPTION Slot .022" x .028" Kit variations: length torque angle Off In-out Replacement .022" x .028" Slot quantity Reference 05.21.0890 Hooks on 3. 4 & 5 20 brackets 74.82.910P - Hooks on 3 .022 3 mm -7° 0° 2° 0.25 mm 3 mm -7° 0° 2° 0.25 mm 3 mm -7° 8° 4° 0.25 mm 2.7 mm 10° 8° 0° 0.65 mm 2.9 mm 17° 4° 0° 0.50 mm 2.9 mm 17° 4° - 0° 0.50 mm 2.7 mm 10° 8° 0° 0.65 mm 3 mm -7° 8° 4° 0.25 mm 3 mm -7° 0° 2° 0.25mm 3 mm -7° 0° 2° 0.25 mm 05.21.0814 5 5 15 05.21.0814 5 4 14 05.21.0813 5 3 13 05.21.0812 5 2 12 05.21.0811 5 1 11 05.21.0821 5 1 21 05.21.0822 5 2 22 05.21.0823 5 3 23 05.21.0824 5 4 24 05.21.0824 5 5 25 45 5 3 mm -17° 2° 4° 0.15 mm 44 4 3 mm -12° 2° 4° 0.15 mm 43 3 2.9 mm -6° 3° 2° 0.20 mm 42 2 2.7 mm -6° 0° 0° 0.45 mm 41 1 2.7 mm -6° 0° 0° 0.45 mm 31 1 2.7 mm -6° 0° 0° 0.45 mm 32 2 2.7 mm -6° 0° 0° 0.45 mm 33 3 2.9 mm -6° 3° 2° 0.20 mm 34 4 3 mm -12° 2° 4° 0.15 mm 35 5 3 mm -17° 2° 4° 0.15 mm 05.21.0845 5 05.21.0844 5 05.21.0843 5 05.21.0841 5 74.82.841P 5 74.82.841P 5 74.82.841P 5 05.21.0833 5 05.21.0834 5 05.21.0835 5 Upper Lower length torque angle Off In-out Replacement .022" x .028" Slot quantity SYSTEM CONFIGURATIONS TOTALLY PASSIVE - .022" TOTALLY INTERACTIVE - .022" Less ligation friction and lower force mechanics throughout treatment. No wires are actively engaged by the clip. Less ligation friction during initial leveling and aligning. Increased torque and rotation control during finishing. Hybrid & Dual Slot Systems HYBRID SYSTEM Interactive .022" / Passive .022" HYBRID DUAL SLOT SYSTEM Interactive .018" / Passive .022" INTERACTIVE DUAL SLOT SYSTEM Interactive .018" / Interactive .022" Features the same slot size and both passive and interactive self-ligating brackets. Features different slot sizes and both passive and interactive selfligating brackets. Features different slot sizes and only interactive self-ligating brackets. Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation. 7 Brackets-Self-Ligating INTERACTIVE DAMON STANDARD PRESCRIPTION Slot .022" x .028" Kit variations: length torque angle Off In-out Replacement .022" x .028" Slot quantity Reference 74.02.900SI Hooks on 3. 4 & 5 20 brackets 74.02.910SI - Hooks on 3 .022 3 mm -11° 2° 2° 0.25 mm 3 mm -11° 2° 2° 0.25mm 3 mm 7° 5° 4° 0.25 mm 2.7 mm 6° 9° 0° 0.65 mm 2.9 mm 15° 5° 0° 0.50 mm 2.9 mm 15° 5° 0° 0.50 mm 2.7 mm 6° 9° 0° 0.65 mm 3 mm 7° 5° 4° 0.25 mm 3 mm -11° 2° 2° 0.25 mm 3 mm -11° 2° 2° 0.25 mm 74.02.814IS 74.02.814IS 74.02.813IS 74.02.812IS 74.02.811IS 74.02.821IS 74.02.822IS 74.02.823IS 74.02.824IS 74.02.824IS 5 5 5 5 5 5 5 5 5 5 5 43 211 234 5 15 1413 121121 222324 25 Upper Lower length torque angle Off In-out Replacement .022" x .028" Slot quantity 45 4443 424131 323334 35 5 43 211 234 5 3 mm 3 mm 2.9 mm 2.7 mm 2.7 mm 2.7 mm 2.7 mm 2.9 mm 3 mm 3 mm -17° -12° 7° -3° -3° -3° -3° 7° -12° -17° 4° 4° 5° 4° 2° 2° 4° 5° 4° 4° 4° 4° 2° 0° 0° 0° 0° 2° 4° 4° 0.15 mm 0.15 mm 0.20 mm 0.45 mm 0.45 mm 0.45 mm 0.45 mm 0.20 mm 0.15 mm 0. 15 mm 74.02.845IS 5 74.02.844IS 5 74.02.843IS 5 74.02.842IS 5 74.02.841IS 5 74.02.831IS 5 74.02.832IS 5 74.02.833IS 5 74.02.834IS 5 74.02.835IS 5 2.7 mm -5° 9° 0° 0.65 mm 2.9 mm 2° 5° 0° 0.50 mm 2.9 mm 2° 5° 0° 0.50 mm 2.7 mm -5° 9° 0° 0.65 mm 3 mm -9° 5° 4° 0.25 mm 3 mm -11° 2° 2° 0.25 mm 3 mm -11° 2° 2° 0.25 mm DAMON LOW TORQUE PRESCRIPTION Slot .022" x .028" Kit variations: length torque angle Off In-out Replacement .022" x .028" Slot quantity Reference 74.02.900LI Hooks on 3. 4 & 5 20 brackets 74.02.910LI - Hooks on 3 .022 3 mm -11° 2° 2° 0.25 mm 3 mm -11° 2° 2° 0.25mm 3 mm -9° 5° 4° 0.25 mm 74.02.814IS 74.02.814IS 74.02.813IL 74.02.812IL 74.02.811IL 74.02.821IL 74.02.822IL 74.02.823IL 74.02.824IS 74.02.824IS 5 5 5 5 5 5 5 5 5 5 5 43 211 234 5 15 1413 121121 222324 25 Upper Lower length torque angle Off In-out Replacement .022" x .028" Slot quantity 45 4443 424131 323334 35 5 43 211 234 5 3 mm 3 mm 2.9 mm 2.7 mm 2.7 mm 2.7 mm 2.7 mm 2.9 mm 3 mm 3 mm -17° -12° 0° -11° -11° -11° -11° 0° -12° -17° 4° 4° 5° 4° 2° 2° 4° 5° 4° 4° 4° 4° 2° 0° 0° 0° 0° 2° 4° 4° 0.15 mm 0.15 mm 0.20 mm 0.45 mm 0.45 mm 0.45 mm 0.45 mm 0.20 mm 0.15 mm 0. 15 mm 74.02.845IS 5 74.02.844IS 5 74.02.843IL 5 74.02.842IL 5 74.02.841IL 5 74.02.831IL 5 74.02.832IL 5 74.02.833IL 5 74.02.834IS 5 Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation. 8 74.02.835IS 5 Brackets-Self-Ligating INTERACTIVE DAMON HIGH TORQUE PRESCRIPTION Kit variations: length torque angle Off In-out Replacement .022" x .028" Slot quantity 74.02.910AI/BI/CI - Hooks on 3 .022 3 mm -11° 2° 2° 0.25 mm 3 mm -11° 2° 2° 0.25mm 3 mm 11° 5° 4° 0.25 mm 2.7 mm 13° 9° 0° 0.65 mm 2.9 mm 22° 5° 0° 0.50 mm 2.9 mm 22° 5° 0° 0.50 mm 2.7 mm 13° 9° 0° 0.65 mm 3 mm 11° 5° 4° 0.25 mm 3 mm -11° 2° 2° 0.25 mm 3 mm -11° 2° 2° 0.25 mm 74.02.814IS 74.02.814IS 74.02.813IH 74.02.812IH 74.02.811IH 74.02.821IH 74.02.822IH 74.02.823IH 74.02.824IS 74.02.824IS 5 5 5 5 5 5 5 5 5 5 5 43 211 234 5 15 1413 121121 222324 25 Upper Lower length torque angle Off In-out Replacement .022" x .028" Slot quantity 45 4443 424131 323334 35 5 43 211 234 5 3 mm 3 mm 2.9 mm 2.7 mm 2.7 mm 2.7 mm 2.7 mm 2.9 mm 3 mm 3 mm -17° -5° 13° 0° 0° 0° 0° +13° -5° -17° 4° 4° 5° 0° 0° 0° 0° 5° 4° 4° 4° 4° 2° 0° 0° 0° 0° 2° 4° 4° 0.15 mm 0.15 mm 0.20 mm 0.45 mm 0.45 mm 0.45 mm 0.45 mm 0.20 mm 0.15 mm 0. 15 mm 74.02.845IS 5 74.02.844IH 5 74.02.843IH 5 74.02.841IH 5 74.02.841IH 5 74.02.841IH 5 74.02.841IH 5 74.02.833IH 5 74.02.834IH 5 74.02.835IS 5 2.7 mm 8° 9° 0° 0.65 mm 2.9 mm 12° 5° 0° 0.50 mm 2.9 mm 12° 5° 0° 0.50 mm 2.7 mm 8° 9° 0° 0.65 mm 3 mm 0° 11° 4° 0.25 mm 3 mm -7° 0° 2° 0.25mm 3 mm -7° 0° 2° 0.25 mm ROTH PRESCRIPTION Slot .022" x .028" Kit variations: length torque angle Off In-out Replacement .022" x .028" Slot quantity Reference 05.23.0390 Hooks on 3. 4 & 5 20 brackets 74.32.910I - Hooks on 3 .022 3 mm -7° 0° 2° 0.25 mm 3 mm -7° 0° 2° 0.25 mm 3 mm 0° 11° 4° 0.25 mm 74.32.814I 74.32.814I 74.32.813I 74.32.812I 74.32.811I 74.32.821I 74.32.822I 74.32.823I 74.32.824I 74.32.824I 5 5 5 5 5 5 5 5 5 5 5 43 211 234 5 15 1413 121121 222324 25 Upper Lower length torque angle Off In-out Replacement .022" x .028" Slot quantity 45 4443 424131 323334 35 5 43 211 234 5 3 mm 3 mm 2.9 mm 2.7 mm 2.7 mm 2.7 mm 2.7 mm 2.9 mm 3 mm 3 mm -22° -17° -11° 0° 0° 0° 0° -11° -17° -22° 0° 0° 5° 0° 0° 0° 0° 5° 0° 0° 4° 4° 2° 0° 0° 0° 0° 2° 4° 4° 0.15 mm 0.15 mm 0.20 mm 0.45 mm 0.45 mm 0.45 mm 0.45 mm 0.20 mm 0.15 mm 0.15 mm 74.32.845I 5 74.32.844I 5 74.32.843I 5 74.32.841I 5 74.32.841I 5 74.32.841I 5 74.32.841I 5 74.32.833I 5 74.32.834I 5 Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation. 9 74.32.835I 5 Brackets-^ĞůĨͲ>ŝŐĂƟŶŐ INTERACTIVE MBT PRESCRIPTION Slot .022" x .028" Reference 05.23.0890 Hooks on 3. 4 & 5 20 brackets 74.82.910I - Hooks on 3 .022 Kit variations: length torque angle Off In-out Replacement .022" x .028" Slot quantity 3 mm -7° 0° 2° 0.25 mm 3 mm -7° 0° 2° 0.25 mm 3 mm -7° 8° 4° 0.25 mm 2.7 mm 10° 8° 0° 0.65 mm 2.9 mm 17° 4° 0° 0.50 mm 2.9 mm 17° 4° 0° 0.50 mm 2.7 mm 10° 8° 0° 0.65 mm 3 mm -7° 8° 4° 0.25 mm 3 mm -7° 0° 2° 0.25mm 3 mm -7° 0° 2° 0.25 mm 05.23.0814 5 5 15 05.23.0814 5 4 14 05.23.0813 5 3 13 05.23.0812 5 2 12 05.23.0811 5 1 11 05.23.0821 5 1 21 05.23.0822 5 2 22 05.23.0823 5 3 23 05.23.0824 5 4 24 05.23.0824 5 5 25 45 5 3 mm -17° 0° 4° 0.15 mm 44 4 3 mm -12° 0° 4° 0.15 mm 43 3 2.9 mm -6° 3° 2° 0.20 mm 42 2 2.7 mm -6° 0° 0° 0.45 mm 41 1 2.7 mm -6° 0° 0° 0.45 mm 31 1 2.7 mm -6° 0° 0° 0.45 mm 32 2 2.7 mm -6° 0° 0° 0.45 mm 33 3 2.9 mm -6° 3° 2° 0.20 mm 34 4 3 mm -12° 2° 4° 0.15 mm 35 5 3 mm -17° 2° 4° 0.15 mm 05.23.0845 5 05.23.0844 5 05.23.0843 5 05.23.0841 5 05.23.0841 5 05.23.0841 5 05.23.0841 5 05.23.0833 5 05.23.0834 5 05.23.0835 5 Upper Lower length torque angle Off In-out Replacement .022" x .028" Slot quantity FEATURES / BENEFITS • Lowest profile on the market • Thermal NiTi Clip / Planar design for easy opening and secure engagement Passive System • Combines the best of both Passive and Interactive treatment techniques with familiar geometric design • System can be utilized as: - Fully Passive - Fully Interactive, or - Combinations of both • Allows orthodontists full control from start to finish Interactive System • More comfortable for patients • Reduces friction and improves sliding mechanics • Fewer patient visits compared to traditional brackets • Open mini twin design for easy positioning reference and maximum patient hygiene Hybrid Systems Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation. 10 Brackets-Self-Ligating HYBRID SYSTEM - Interactive .022" / Passive .022" DAMON STANDARD PRESCRIPTION Slot .022" x .028" Kit variations: length torque angle Off In-out Replacement .022" x .028" Slot quantity Reference 74.02.900SD Hooks on 3. 4 & 5 20 brackets 74.02.910SD - Hooks on 3 .022 3 mm -11° 2° 2° 0.25 mm 3 mm -11° 2° 2° 0.25 mm 3 mm 7° 5° 4° 0.25 mm 2.7 mm 6° 9° 0° 0.65 mm 2.9 mm 15° 5° 0° 0.50 mm 2.9 mm 15° 5° 0° 0.50 mm 2.7 mm 6° 9° 0° 0.65 mm 3 mm 7° 5° 4° 0.25mm 3 mm -11° 2° 2° 0.25 mm 3 mm -11° 2° 2° 0.25 mm 74.02.814PS 74.02.814PS 74.02.813PS 74.02.812IS 74.02.811IS 74.02.821IS 74.02.822IS 74.02.823PS 74.02.824PS 74.02.824PS 5 5 5 5 5 5 5 5 5 5 5 43 211 234 5 15 1413 121121 222324 25 Upper Lower length torque angle Off In-out Replacement .022" x .028" Slot quantity 45 4443 424131 323334 35 5 43 211 234 5 3 mm 3 mm 2.9 mm 2.7 mm 2.7 mm 2.7 mm 2.7 mm 2.9 mm 3 mm 3 mm -17° -12° 7° -3° -3° -3° -3° 7° -12° -17° 4° 4° 5° -4° 2° 2° 4 5° 4° 4° 4° 4° 2° 0° 0° 0° 0° 2° 4° 4° 0.15 mm 0.15 mm 0.20 mm 0.45 mm 0.45 mm 0.45 mm 0.45 mm 0.20 mm 0.15 mm 0.15 mm 74.02.845PS 5 74.02.844PS 5 74.02.843PS 5 74.02.842IS 5 74.02.841IS 5 74.02.831IS 5 74.02.832IS 5 74.02.833PS 5 74.02.834PS 5 74.02.835PS 5 2.7 mm -5° 9° 0° 0.65 mm 2.9 mm 2° 5° 0° 0.50 mm 2.9 mm 2° 5° 0° 0.50 mm 2.7 mm -5° 9° 0° 0.65 mm 3 mm -9° 5° 4° 0.25 mm 3 mm -11° 2° 2° 0.25mm 3 mm -11° 2° 2° 0.25 mm DAMON LOW TORQUE PRESCRIPTION Slot .022" x .028" Kit variations: length torque angle Off In-out Replacement .022" x .028" Slot quantity Reference 74.02.900LD Hooks on 3. 4 & 5 20 brackets 74.02.910LD - Hooks on 3 .022 3 mm -11° 2° 2° 0.25 mm 3 mm -11° 2° 2° 0.25 mm 3 mm -9° 5° 4° 0.25 mm 74.02.814PS 74.02.814PS 74.02.813PL 74.02.812IL 74.02.811IL 74.02.821IL 74.02.822IL 74.02.823PL 74.02.824PS 74.02.824PS 5 5 5 5 5 5 5 5 5 5 5 43 211 234 5 15 1413 121121 222324 25 Upper Lower length torque angle Off In-out Replacement .022" x .028" Slot quantity 45 4443 424131 323334 35 5 43 211 234 5 3 mm 3 mm 2.9 mm 2.7 mm 2.7 mm 2.7 mm 2.7 mm 2.9 mm 3 mm 3 mm -17° -12° 0° -11° -11° -11° -11° 0° -12° -17° 4° 4° 5° 4° 2° 2° 4° 5° 4° 4° 4° 4° 2° 0° 0° 0° 0° 2° 4° 4° 0.15 mm 0.15 mm 0.20 mm 0.45 mm 0.45 mm 0.45 mm 0.45 mm 0.20 mm 0.15 mm 0.15 mm 74.02.845PS 5 74.02.844PS 5 74.02.843PL 5 74.02.842IL 5 74.02.841IL 5 74.02.831IL 5 74.02.832IL 5 74.02.833PL 5 74.02.834PS 5 Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation. 11 74.02.835PS 5 Brackets-Self-Ligating HYBRID SYSTEM - Interactive .022" / Passive .022" DAMON HIGH TORQUE PRESCRIPTION Slot .022" x .028" .022" x .028" .022" x .028" Reference 74.02.900AD 74.02.900BD 74.02.900CD length torque angle Off In-out Replacement .022" x .028" Slot quantity Hooks on 3. 4 & 5 Teeth 41/31/42/32 0°T 0°A Teeth 41/31 -3°T 2°A 42/32 -3°T 4°A Teeth 41/31/42/32 -6°T 2°A 3 mm -11° 2° 2° 0.25 mm 3 mm -11° 2° 2° 0.25 mm 3 mm 11° 5° 4° 0.25 mm 2.7 mm 13° 9° 0° 0.65 mm Kit variations: 2.9 mm 22° 5° 0° 0.50 mm 2.9 mm 22° 5° 0° 0.50 mm 74.02.910AD/BD/CD - Hooks on 3 .022 2.7 mm 13° 9° 0° 0.65 mm 3 mm 11° 5° 4° 0.25 mm 3 mm -11° 2° 2° 0.25mm 3 mm -11° 2° 2° 0.25 mm 74.02.814PS 74.02.814PS 74.02.813PH 74.02.812IH 74.02.811IH 74.02.821IH 74.02.822IH 74.02.823PH 74.02.824PS 74.02.824PS 5 5 5 5 5 5 5 5 5 5 5 43 211 234 5 15 1413 121121 222324 25 Upper Lower length torque angle Off In-out Replacement .022" x .028" Slot quantity 45 4443 424131 323334 35 5 43 211 234 5 3 mm 3 mm 2.9 mm 2.7 mm 2.7 mm 2.7 mm 2.7 mm 2.9 mm 3 mm 3 mm -17° -5° 13° 0° 0° 0° 0° 13° -5° -17° 4° 4° 5° 0° 0° 0° 0° 5° 4° 4° 4° 4° 2° 0° 0° 0° 0° 2° 4° 4° 0.15 mm 0.15 mm 0.20 mm 0.45 mm 0.45 mm 0.45 mm 0.45 mm 0.20 mm 0.15 mm 0.15 mm 74.02.845PS 5 74.02.844PH 5 74.02.843PH 5 74.02.841IH 5 74.02.841IH 5 74.02.841IH 5 74.02.841IH 5 74.02.833PH 5 74.02.834PH 5 74.02.835PS 5 2.7 mm 8° 9° 0° 0.65 mm 2.9 mm 12° 5° 0° 0.50 mm 2.9 mm 12° 5° 0° 0.50 mm 2.7 mm 8° 9° 0° 0.65 mm 3 mm 0° 11° 4° 0.25 mm 3 mm -7° 0° 2° 0.25mm 3 mm -7° 0° 2° 0.25 mm ROTH PRESCRIPTION Slot .022" x .028" Kit variations: length torque angle Off In-out Replacement .022" x .028" Slot quantity Reference 05.25.0390 Hooks on 3. 4 & 5 20 brackets 74.32.910D - Hooks on 3 .022 3 mm -7° 0° 2° 0.25 mm 3 mm -7° 0° 2° 0.25 mm 3 mm 0° 11° 4° 0.25 mm 74.32.814P 74.32.814P 74.32.813P 74.32.812I 74.32.811I 74.32.821I 74.32.822I 74.32.823P 74.32.824P 74.32.824P 5 5 5 5 5 5 5 5 5 5 5 43 211 234 5 15 1413 121121 222324 25 Upper Lower length torque angle Off In-out Replacement .022" x .028" Slot quantity 45 4443 424131 323334 35 5 43 211 234 5 3 mm 3 mm 2.9 mm 2.7 mm 2.7 mm 2.7 mm 2.7 mm 2.9 mm 3 mm 3 mm -22° -17° -11° 0° 0° 0° 0° -11° -17° -22° 0° 0° 5° 0° 0° 0° 0° 5° 0° 0° 4° 4° 2° 0° 0° 0° 0° 2° 4° 4° 0.15 mm 0.15 mm 0.20 mm 0.45 mm 0.45 mm 0.45 mm 0.45 mm 0.20 mm 0.15 mm 0.15 mm 74.32.845P 5 74.32.844P 5 74.32.843P 5 74.32.841I 5 74.32.841I 5 74.32.841I 5 74.32.841I 5 74.32.833P 5 74.32.834P 5 Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation. 12 74.32.835P 5 Brackets-^ĞůĨͲ>ŝŐĂƟŶŐ HYBRID SYSTEM - Interactive .022" / Passive .022" MBT PRESCRIPTION Slot .022" x .028" Reference 05.25.0890 Hooks on 3. 4 & 5 20 brackets 74.82.910D - Hooks on 3 .022 Kit variations: length torque angle Off In-out Replacement .022" x .028" Slot quantity 3 mm -7° 0° 2° 0.25 mm 3 mm -7° 0° 2° 0.25 mm 3 mm -7° 8° 4° 0.25 mm 2.7 mm 10° 8° 0° 0.65 mm 2.9 mm 17° 4° 0° 0.50 mm 2.9 mm 17° 4° 0° 0.50 mm 2.7 mm 10° 8° 0° 0.65 mm 3 mm -7° 8° 4° 0.25 mm 3 mm -7° 0° 2° 0.25mm 3 mm -7° 0° 2° 0.25 mm 74.82.814P 5 5 15 74.82.814P 5 4 14 74.82.813P 5 3 13 74.82.812I 5 2 12 74.82.811I 5 1 11 74.82.821I 5 1 21 74.82.822I 5 2 22 74.82.823P 5 3 23 74.82.824P 5 4 24 74.82.824P 5 5 25 45 5 3 mm -17° 0° 4° 0.15 mm 44 4 3 mm -12° 0° 4° 0.15 mm 43 3 2.9 mm -6° 3° 2° 0.20 mm 42 2 2.7 mm -6° 0° 0° 0.45 mm 41 1 2.7 mm -6° 0° 0° 0.45 mm 31 1 2.7 mm -6° 0° 0° 0.45 mm 32 2 2.7 mm -6° 0° 0° 0.45 mm 33 3 2.9 mm -6° 3° 2° 0.20 mm 34 4 3 mm -12° 2° 4° 0.15 mm 35 5 3 mm -17° 2° 4° 0.15 mm 74.82.845P 5 74.82.844P 5 74.82.843P 5 74.82.841I 5 74.82.841I 5 74.82.841I 5 74.82.841I 5 74.82.833P 5 74.82.834P 5 74.82.835P 5 Upper Lower length torque angle Off In-out Replacement .022" x .028" Slot quantity To learn more about EasyClip+ and our complete line of brackets, visit our interactive bracket website or contact us today! www.GreatLakesBrackets.com Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation. 13 Brackets-Self-Ligating HYBRID DUAL SLOT SYSTEM - Interactive .018" / Passive .022" ROTH PRESCRIPTION Slot .022" x .028" Kit variations: length torque angle Off In-out Replacement .022" x .028" Slot quantity Reference 05.25.0390B Hooks on 3. 4 & 5 20 brackets 74.32.910DB - Hooks on 3 .022 3 mm -7° 0° 2° 0.25 mm 3 mm -7° 0° 2° 0.25 mm 3 mm 0° 11° 4° 0.25 mm 2.7 mm 8° 9° 0° 0.65 mm 2.9 mm 12° 5° 0° 0.50 mm 2.9 mm 12° 5° 0° 0.50 mm 2.7 mm 8° 9° 0° 0.65 mm 3 mm 0° 11° 4° 0.25 mm 3 mm -7° 0° 2° 0.25mm 3 mm -7° 0° 2° 0.25 mm 74.32.814P 74.32.814P 74.32.813P 74.31.812I 74.31.811I 74.31.821I 74.31.822I 74.32.823P 74.32.824P 74.32.824P 5 5 5 5 5 5 5 5 5 5 5 43 211 234 5 15 1413 121121 222324 25 Upper Lower length torque angle Off In-out Replacement .022" x .028" Slot quantity 45 4443 424131 323334 35 5 43 211 234 5 3 mm 3 mm 2.9 mm 2.7 mm 2.7 mm 2.7 mm 2.7 mm 2.9 mm 3 mm 3 mm -22° -17° -11° 0° 0° 0° 0° -11° -17° -22° 0° 0° 5° 0° 0° 0° 0° 5° 0° 0° 4° 4° 2° 0° 0° 0° 0° 2° 4° 4° 0.15 mm 0.15 mm 0.20 mm 0.45 mm 0.45 mm 0.45 mm 0.45 mm 0.20 mm 0.15 mm 0.15 mm 74.32.845P 5 74.32.844P 5 74.32.843P 5 74.31.841I 5 74.31.841I 5 74.31.841I 5 74.31.841I 5 74.32.833P 5 74.32.834P 5 74.32.835P 5 2.7 mm 10° 8° 0° 0.65 mm 2.9 mm 17° 4° 0° 0.50 mm 2.9 mm 17° 4° 0° 0.50 mm 2.7 mm 10° 8° 0° 0.65 mm 3 mm -7° 8° 4° 0.25 mm 3 mm -7° 0° 2° 0.25mm 3 mm -7° 0° 2° 0.25 mm MBT PRESCRIPTION Slot .022" x .028" Kit variations: length torque angle Off In-out Replacement .022" x .028" Slot quantity Reference 05.25.0890B Hooks on 3. 4 & 5 20 brackets 74.02.910LD - Hooks on 3 .022 3 mm -7° 0° 2° 0.25 mm 3 mm -7° 0° 2° 0.25 mm 3 mm -7° 8° 4° 0.25 mm 74.82.814P 74.82.814P 74.82.813P 74.81.812I 74.81.811I 74.81.821I 74.81.822I 74.82.823P 74.82.824P 74.82.824P 5 5 5 5 5 5 5 5 5 5 5 43 211 234 5 15 1413 121121 222324 25 Upper Lower length torque angle Off In-out Replacement .022" x .028" Slot quantity 45 4443 424131 323334 35 5 43 211 234 5 3 mm 3 mm 2.9 mm 2.7 mm 2.7 mm 2.7 mm 2.7 mm 2.9 mm 3 mm 3 mm -17° -12° -6° -6° -6° -6° -6° -6° -12° -17° 2° 2° 3° 0° 0° 0° 0° 3° 2° 2° 4° 4° 2° 0° 0° 0° 0° 2° 4° 4° 0.15 mm 0.15 mm 0.20 mm 0.45 mm 0.45 mm 0.45 mm 0.45 mm 0.20 mm 0.15 mm 0.15 mm 74.82.845P 5 74.82.844P 5 74.82.843P 5 74.81.841I 5 74.81.841I 5 74.81.841I 5 74.81.841I 5 74.82.833P 5 74.82.834P 5 Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation. 14 74.82.835P 5 Brackets-Self-Ligating INTERACTIVE DUAL SLOT SYSTEM - Interactive .018" / Interactive .022" ROTH PRESCRIPTION Slot .022" x .028" Kit variations: length torque angle Off In-out Replacement .022" x .028" Slot quantity Reference 05.23.0390B Hooks on 3. 4 & 5 20 brackets 7 4.32.910IB - Hooks on 3 .022 3 mm 3 mm 3 mm -7° -7° 0° 0° 0° 11° 2° 2° 4° 0.25 mm 0.25 mm 0.25 mm 2.7 mm 8° 9° 0° 0.65 mm 2.9 mm 12° 5° 0° 0.50 mm 2.9 mm 12° 5° 0° 0.50 mm 2.7 mm 8° 9° 0° 0.65 mm 3 mm 0° 11° 4° 0.25 mm 3 mm -7° 0° 2° 0.25mm 3 mm -7° 0° 2° 0.25 mm 74.32.814I 74.32.814I 74.32.813I 74.31.812I 74.31.811I 74.31.821I 74.31.822I 74.32.823I 74.32.824I 74.32.824I 5 5 5 5 5 5 5 5 5 5 5 43 211 234 5 15 1413 121121 222324 25 Upper Lower length torque angle Off In-out Replacement .022" x .028" Slot quantity 45 4443 424131 323334 35 5 43 211 234 5 3 mm 3 mm 2.9 mm 2.7 mm 2.7 mm 2.7 mm 2.7 mm 2.9 mm 3 mm 3 mm -22° -17° -11° 0° 0° 0° 0° -11° -17° -22° 0° 0° 5° 0° 0° 0° 0° 5° 0° 0° 4° 4° 2° 0° 0° 0° 0° 2° 4° 4° 0.15 mm 0.15 mm 0.20 mm 0.45 mm 0.45 mm 0.45 mm 0.45 mm 0.20 mm 0.15 mm 0.15 mm 74.32.845I 5 74.32.844I 5 74.32.843I 5 74.31.841I 5 74.31.841I 5 74.31.841I 5 74.31.841I 5 74.32.833I 5 74.32.834I 5 74.32.835I 5 2.7 mm 10° 8° 0° 0.65 mm 2.9 mm 17° 4° 0° 0.50 mm 2.9 mm 17° 4° 0° 0.50 mm 2.7 mm 10° 8° 0° 0.65 mm 3 mm -7° 8° 4° 0.25 mm 3 mm -7° 0° 2° 0.25mm 3 mm -7° 0° 2° 0.25 mm MBT PRESCRIPTION Slot .022" x .028" Kit variations: length torque angle Off In-out Replacement .022" x .028" Slot quantity Reference 05.23.0890B Hooks on 3. 4 & 5 20 brackets 74.82.910IB - Hooks on 3 .022 3 mm -7° 0° 2° 0.25 mm 3 mm -7° 0° 2° 0.25 mm 3 mm -7° 8° 4° 0.25 mm 74.82.814I 74.82.814I 74.82.813I 74.81.812I 74.81.811I 74.81.821I 74.81.822I 74.82.823I 74.82.824I 74.82.824I 5 5 5 5 5 5 5 5 5 5 5 43 211 234 5 15 1413 121121 222324 25 Upper Lower length torque angle Off In-out Replacement .022" x .028" Slot quantity 45 4443 424131 323334 35 5 43 211 234 5 3 mm 3 mm 2.9 mm 2.7 mm 2.7 mm 2.7 mm 2.7 mm 2.9 mm 3 mm 3 mm -17° -12° -6° -6° -6° -6° -6° -6° -12° -17° 0° 0° 3° 0° 0° 0° 0° 3° 2° 2° 4° 4° 2° 0° 0° 0° 0° 2° 4° 4° 0.15 mm 0.15 mm 0.20 mm 0.45 mm 0.45 mm 0.45 mm 0.45 mm 0.20 mm 0.15 mm 0.15 mm 74.82.845I 5 74.82.844I 5 74.82.843I 5 74.81.841I 5 74.81.841I 5 74.81.841I 5 74.81.841I 5 74.82.833I 5 74.82.834I 5 Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation. 15 74.82.835I 5 Great Lakes BioTru™ Classic Completely programmed for a true straight wire system that positions teeth at all four levels: In/Out • Angulations Torque • Overcorrection Bracket System Center scribe line aligns with the long axis for accurate placement 17-4 PH stainless steel for higher strength Full rotational control due to mesial to distal width and twin design ID color coding for easy bracket selection Microcast - consistent, exact tolerances Anatomical hook Compound contour base for easy, accurate placement Ample tie-wing undercuts to facilitate ligation BENEFITS Rounded tie wings for patient comfort Torque in base for level slot lineup and improved finishing Diamond-shaped geometry for accurate placement • 4-Dimensional appliance bracket needs no offset bends in the archwire to obtain an optimal finish. • Torque in base designed to provide level slot lineup, and helps avoid occlusal interference. • Foil mesh bonding pad matches the curvature of the tooth for maximum contact and a strong, consistent bond. • Special option available for bicuspid brackets that feature a gingivally offset bonding base. CHARACTERISTICS • Rounded tie wings for patient comfort (Standard size) • Color-coded enhanced ID for easy bracket selection • Lowest possible profile without compromising the straight wire characteristics of the system • Manufactured from 17-4 PH surgical grade stainless steel • Standardized In/Outs for precision and consistency • Diamond-shaped tie-wings are parallel to the tooth anatomy for accurate placement • Vertical aspects follow the long axis of the tooth - Horizontal aspects run parallel to the occlusal plane • Twin design for full rotational control • Palladium brazing alloy for maximum solder joint strength • .080 mesh pad for increased bond strength • 100% quality check ensures exact slot tolerances .080 mesh base for increased bond strength APPLICATIONS • This classic bracket system combines the concepts of traditional orthodontics with the latest engineering and production processes. • Professionals have the ability to choose from a wide range of treatment options and protocols to best meet the needs of your clients and your practice. • Ideal for all treatment patterns as brackets can be interchanged within prescriptions. • All bracket prescriptions utilize the same In/Out for slot level alignment and interchangeability. • Provides doctors with full control from start to finish with a completely adjusted straight wire appliance. AVAILABLE PRESCRIPTIONS • Roth • MBT .018" and .022" Slots Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation. 16 Brackets BioTru™ Classic ROTH PRESCRIPTION Slot .022" x .028" .018" x .028" Kit variations: length Torque angle Replacement .022" x .028" .018" x .028" Slot quantity Reference 05.10.0390 05.09.0390 Hooks on 3. 4 & 5 20 brackets 20 brackets 12.32.910 - Hooks on 3 .022 12.31.910 - Hooks on 3 .018 12.32.901 - Kit Offset Hooks on 3/4/5 .022 12.31.901 - Kit Offset Hooks on 3/4/5 .018 3.2 mm -7° 0° 3.2 mm -7° 0° 3.5 mm 0° 11° 3.2 mm 8° 9° 3.9 mm 12° 5° 3.9 mm 12° 5° 3.2 mm 8° 9° 3.5 mm 0° 11° 3.2 mm -7° 0° 3.2 mm -7° 0° 05.10.0314 05.09.0314 10 5 15 05.10.0314 05.09.0314 10 4 14 05.10.0313 05.09.0313 10 3 13 05.10.0312 05.09.0312 10 2 12 05.10.0311 05.09.0311 10 1 11 05.10.0321 05.09.0321 10 1 21 05.10.0322 05.09.0322 10 2 22 05.10.0323 05.09.0323 10 3 23 05.10.0324 05.09.0324 10 4 24 05.10.0324 05.09.0324 10 5 25 45 5 3.3 mm -22° 0° 44 4 3.3 mm -17° 0° 43 3 3.5 mm -11° 5° 42 2 2.5 mm 0° 0° 41 1 2.5 mm 0° 0° 31 1 2.5 mm 0° 0° 32 2 2.5 mm 0° 0° 33 3 3.5 mm -11° 5° 34 4 3.3 mm -17° 0° 35 5 3.3 mm -22° 0° 05.10.0345 05.09.0345 10 05.10.0344 05.09.0344 10 05.10.0343 05.09.0343 10 05.10.0341 05.09.0341 10 05.10.0341 05.09.0341 10 05.10.0341 05.09.0341 10 05.10.0341 05.09.0341 10 05.10.0333 05.09.0333 10 05.10.0334 05.09.0334 10 05.10.0335 05.09.0335 10 Upper Lower length Torque angle Replacement .022" x .028" Slot .018" x .028" quantity MBT PRESCRIPTION Slot .022" x .028" .018" x .028" Kit variations: length Torque angle Replacement .022" x .028" Slot .018" x .028" quantity Reference 05.10.0890 05.09.0890 Hooks on 3. 4 & 5 20 brackets 20 brackets 12.82.910 - Hooks on 3 .022 12.81.910 - Hooks on 3 .018 12.82.901 - Kit Offset Hooks on 3/4/5 .022 12.81.901 - Kit Offset Hooks on 3/4/5 .018 3.2 mm -7° 0° 3.2 mm -7° 0° 3.5 mm -7° 8° 3.2 mm 10° 8° 3.9 mm 17° 4° 3.9 mm 17° 4° 3.2 mm 10° 8° 3.5 mm -7° 8° 3.2 mm -7° 0° 3.2 mm -7° 0° 05.10.0814 12.81.514 10 5 15 05.10.0814 12.81.514 10 4 14 05.10.0813 05.09.0813 10 3 13 05.10.0812 05.09.0812 10 2 12 05.10.0811 05.09.0811 10 1 11 05.10.0821 05.09.0821 10 1 21 05.10.0822 05.09.0822 10 2 22 05.10.0823 05.09.0823 10 3 23 05.10.0824 12.81.524 10 4 24 05.10.0824 12.81.524 10 5 25 45 5 3.3 mm -17° 0° 44 4 3.3 mm -12° 0° 43 3 3.5 mm -6° 3° 42 2 2.5 mm -6° 0° 41 1 2.5 mm -6° 0° 31 1 2.5 mm -6° 0° 32 2 2.5 mm -6° 0° 33 3 3.5 mm -6° 3° 34 4 3.3 mm -12° 0° 35 5 3.3 mm -17° 0° 05.10.0845 05.09.0845 10 05.10.0844 05.09.0844 10 05.10.0843 05.09.0843 10 05.10.0841 05.09.0841 10 05.10.0841 05.09.0841 10 05.10.0841 05.09.0841 10 05.10.0841 05.09.0841 10 05.10.0833 05.09.0833 10 05.10.0834 05.09.0834 10 05.10.0835 05.09.0835 10 Upper Lower length Torque angle Replacement .022" x .028" Slot .018" x .028" quantity Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation. 17 Great Lakes BioTru A unique combination of aesthetics, function, and strength. ™ Ceramic Bracket System Diamond polished archwire slot increases torque control and sliding mechanics Smooth, rounded corners for added patient comfort Blends with natural tooth tone Ample clearance under tie wings Polycrystalline Alumina is highly stain resistant Low profile Dovetail base design debonds easily BENEFITS • Dovetail base design has an interlocking adhesive tooth interface for maximum bond strength, yet debonds easily when needed. • Bracket design and ceramic material are engineered for exceptional bond strength and fracture resistance. APPLICATIONS • Precision cut, diamond polished slots increase torque control and sliding mechanics. • Utilized in patients where aesthetics and cosmetic needs, as well as financial requirements, are a concern. • Made from 99.9% pure Polycrystalline Alumina ensures the translucency patients want. • Provides an invisible, stain resistant appearance throughout the treatment. - Coated steel ligature ties - Coated springs and clear elastic ligature ties CHARACTERISTICS • Translucency blends with the natural tooth tone • Removable color-coded ID dot for easy bracket selection • Does not require any special instruments or adhesive for routine protocol use • Utilizes smooth polished surfaces, rounded corners, and contoured auxiliary hooks for added patient comfort • Easy ligation for ligatures and accessories with ample clearance under tie wings • Rhomboid shape for accurate placement • To enhance overall aesthetics, the following auxiliaries are provided: AVAILABLE PRESCRIPTIONS • Roth • MBT .018" and .022" Slots • Six distinct shapes of foil mesh pad for perfect tooth anatomy fitting • Vertical aspects follow the long axis of the tooth - Horizontal aspects run parallel to the occlusal plane Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation. 18 Brackets-Aesthetic BioTru™ Ceramic ROTH PRESCRIPTION Slot .022" x .028" .018" x .028" length Torque angle Replacement .022" x .028" Slot .018" x .028" quantity Reference 05.03.0390 05.02.0390 Hooks on 3. 4 & 5 20 brackets 20 brackets 3.2 mm -7° 0° 3.2 mm -7° 0° 3.3 mm 0° 11° 3.2 mm 8° 9° 3.6 mm 12° 5° 3.6 mm 12° 5° 3.2 mm 8° 9° 3.3 mm 0° 11° 3.2 mm -7° 0° 3.2 mm -7° 0° 05.03.0314 05.02.0314 1 05.03.0314 05.02.0314 1 05.03.0313 05.02.0313 1 05.03.0312 05.02.0312 1 05.03.0311 05.02.0311 1 05.03.0321 05.02.0321 1 05.03.0322 05.02.0322 1 05.03.0323 05.02.0323 1 05.03.0324 05.02.0324 1 05.03.0324 05.02.0324 1 5 43 211 234 5 15 1413 121121 222324 25 Upper Lower 45 4443 424131 323334 35 5 43 211 234 5 length Torque angle Replacement Slot .022" x .028" .018" x .028" quantity 3.2 mm -22° 0° 3.2 mm -17° 0° 3.4mm -11° 5° 2.9 mm 0° 0° 2.9 mm 0° 0° 2.9 mm 0° 0° 2.9 mm 0° 0° 3.4 mm -11° 5° 3.2 mm -17° 0° 3.2 mm -22° 0° 05.03.0345 05.02.0345 1 05.03.0344 05.02.0344 1 05.03.0343 05.02.0343 1 05.03.0341 05.02.0341 1 05.03.0341 05.02.0341 1 05.03.0341 05.02.0341 1 05.03.0341 05.02.0341 1 05.03.0333 05.02.0333 1 05.03.0334 05.02.0334 1 05.03.0335 05.02.0335 1 MBT PRESCRIPTION Slot .022" x .028" Kit variations: length Torque angle Replacement .022" x .028" Slot quantity Reference 05.03.0890 Hooks on 3. 4 & 5 20 brackets 15.82.910M - Kit Hooks on 3 .022 3.2 mm -7° 0° 3.2 mm -7° 0° 3.3 mm -7° 8° 3.2 mm 10° 8° 3.6 mm 17° 4° 3.6 mm 17° 4° 3.2 mm 10° 8° 3.3 mm -7° 8° 3.2 mm -7° 0° 3.2 mm -7° 0° 05.03.0814 1 05.03.0814 1 05.03.0813 1 05.03.0812 1 05.03.0811 1 05.03.0821 1 05.03.0822 1 05.03.0823 1 05.03.0824 1 05.03.0824 1 5 43 211 234 5 15 1413 121121 222324 25 Upper Lower 45 4443 424131 323334 35 5 43 211 234 5 length Torque angle Replacement .022" x .028" Slot quantity 3.2 mm -17° 0° 3.2 mm -12° 0° 3.4mm -6° 3° 2.9 mm -6° 0° 2.9 mm -6° 0° 2.9 mm -6° 0° 2.9 mm -6° 0° 3.4 mm -6° 3° 3.2 mm -12° 0° 3.2 mm -17° 0° 05.03.0845 1 05.03.0844 1 05.03.0843 1 05.03.0841 1 05.03.0841 1 05.03.0841 1 05.03.0841 1 05.03.0833 1 05.03.0834 1 05.03.0835 1 Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation. 19 Great Lakes BioTru The ultimate in crystal clear aesthetics - highest transparency available ™ Sapphire Bracket System Smooth rounded corners for added patient comfort Diamond polished archwire slot improves sliding mechanics Low profile design and small bracket size Monocrystalline Sapphire does not stain Bond strength enhanced by Zirconia spheres Contoured base allows quick and easy placement Easy-to-ligate tie wings BENEFITS • Invisible against any tooth shade and remains crystal clear without staining. • Diamond polishing/finishing process produces rounded, smooth corners for uncompromised patient comfort. • Exceptionally strong and highly fracture resistant, but also functional with easy-to-ligate tie wings. CHARACTERISTICS • Made from 100% Monocrystalline Sapphire • Smooth, strong, and contoured tie wings • Diamond polished archwire slot for superior sliding mechanics • Ultra-smooth strong hooks provide comfortable, secure engagement of elastics • Contoured bonding base APPLICATIONS • Bond strength is provided by a Zirconia sphere coated base, creating millions of undercuts that mechanically lock with the bracket adhesive. • Secure retention during the length of treatment and predictable debonding at the end of treatment. • Anatomically contoured toothspecific design fits the tooth curvatures perfectly to increase bond strength. • Unique bonding base: Zirconia spheres provide super shear bond strength and predictable debonding • For patients who demand the highest standards in aesthetically cosmetic bracket systems. • Recommended to be utilized with Tooth Tone coated archwires, auxiliaries, and clear elastomeric ligature ties for maximum aesthetics. • Small bracket size and low profile design is ideal for both clinicians and patients. AVAILABLE PRESCRIPTIONS • Roth • MBT .018" and .022" Slots • Removable ID color-coded dot and slot marking for visible reference and accurate bracket placement • Utilizes smooth polished surfaces, rounded corners, and contoured auxiliary hooks for added patient comfort Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation. 20 Brackets-Aesthetic BioTru™ Sapphire ROTH PRESCRIPTION Slot .022" x .028" .018" x .028" length Torque angle Replacement .022" x .028" Slot .018" x .028" quantity Reference 05.15.0390 05.16.0390 Hooks on 3. 4 & 5 20 brackets 20 brackets 3.3 mm -7 ° 0° 3.3 mm -7° 0° 3.3 mm 0° 11° 2.7 mm 8° 9° 3.1 mm 12° 5° 3.1 mm 12° 5° 2.7 mm 8° 9° 3.3 mm 0° 11° 3.3 mm -7° 0° 3.3 mm -7° 0° 05.15.0314 05.16.0314 1 05.15.0314 05.16.0314 1 05.15.0313 05.16.0313 1 05.15.0312 05.16.0312 1 05.15.0311 05.16.0311 1 05.15.0321 05.16.0321 1 05.15.0322 05.16.0322 1 05.15.0323 05.16.0323 1 05.15.0324 05.16.0324 1 05.15.0324 05.16.0324 1 5 43 211 234 5 15 1413 121121 222324 25 Upper Lower 45 4443 424131 323334 35 5 43 211 234 5 length Torque angle Replacement .022" x .028" Slot .018" x .028" quantity 3.3 mm -22° 0° 3.3 mm -17° 0° 3.2 mm -11° 5° 2.6 mm 0° 0° 2.6 mm 0° 0° 2.6 mm 0° 0° 2.6 mm 0° 0° 3.2 mm -11° 5° 3.3 mm -17° 0° 3.3 mm -22° 0° 05.15.0345 05.16.0345 1 05.15.0344 05.16.0344 1 05.15.0343 05.16.0343 1 05.15.0341 05.16.0341 1 05.15.0341 05.16.0341 1 05.15.0341 05.16.0341 1 05.15.0341 05.16.0341 1 05.15.0333 05.16.0333 1 05.15.0334 05.16.0334 1 05.15.0335 05.16.0335 1 MBT PRESCRIPTION Slot .022" x .028" length Torque angle Replacement .022" x .028" Slot quantity Reference 05.15.0890 Hooks on 3. 4 & 5 20 brackets 3.3 mm -7 0 3.3 mm -7 0 3.3 mm -7 8 2.7 mm 10 8 3.1 mm 17 4 3.1 mm 17 4 2.7 mm 10 8 3.3 mm -7 8 3.3 mm -7 0 3.3 mm -7 0 05.15.0814 1 05.15.0814 1 05.15.0813 1 05.15.0812 1 05.15.0811 1 05.15.0821 1 05.15.0822 1 05.15.0823 1 05.15.0824 1 05.15.0824 1 5 43 211 234 5 15 1413 121121 222324 25 Upper Lower 45 4443 424131 323334 35 5 43 211 234 5 length Torque angle Replacement .022" x .028" Slot quantity 3.3 mm -17° 0° 3.3 mm -12° 0° 3.2 mm -6° 3° 2.6 mm -6° 0° 2.6 mm -6° 0° 2.6 mm -6° 0° 2.6 mm -6° 0° 3.2 mm -6° 3° 3.3 mm -12° 0° 3.3 mm -17° 0° 05.15.0845 1 05.15.0844 1 05.15.0843 1 05.15.0841 1 05.15.0841 1 05.15.0841 1 05.15.0841 1 05.15.0833 1 05.15.0834 1 05.15.0835 1 Great Lakes’ version of the Roth and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation. 21 Great Lakes BioMax ® A true Straight Wire system offering efficiency, affordability, and patient satisfaction Bracket System 17-4 PH stainless steel MIM manufacturing for increased strength ‘V’ channel aligns with the long axis for accurate placement Angulated slot for easy wire insertion ID color coding for easy bracket selection Full rotational control due to mesial to distal width and twin design Rounded tie wings for patient comfort Triple chamfered slot walls lessen binding Rhomboid shape with low profile design for patient comfort and secure bonding Ample tie-wing undercuts to facilitate ligation State-of-the-art anatomical base design Mushroom-shaped pylons create undercuts for maximum bond strength BENEFITS • Establishes a new standard for quality and affordability. • A Straight Wire bracket system with rounded contours for greater patient comfort. APPLICATIONS • Generous under tie-wing areas facilitate ligation with either elastomeric or steel ligature ties. • Center scribe ‘V’ channel aligns with the long axis for accurate placement and easy removal of ligature ties. • Designed for error-free bonding positioning due to reference cues with tie wings parallel to the tooth anatomy. • The central ‘V’ channel parallel to the long axis of the clinical crown ensures accurate placement. • Promotes faster ligature tie engagement and removal. CHARACTERISTICS • One piece metal injection molded (MIM) brackets • Faster placement and removal of ligature ties • Fully programmed tooth-shaped designed brackets. A true Straight Wire system • Low profile and rounded contour design for patient comfort • Compound contour base for optimal bonding • Central ‘V’ channel for positioning bonding reference and faster ligature tie removal • Micro-etched base for optimal bond strength • ID marking system on the bracket tie wings • Provides excellent productivity and patient satisfaction at an affordable cost. AVAILABLE PRESCRIPTIONS • Roth .022" Slots • Offset bicuspid bases avoid occlusal interferences Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation. 22 Brackets BioMax® ROTH PRESCRIPTION Slot .022" x .028" Kit variations: Reference 05.04.0390 Hooks on 3. 4 & 5 20 brackets 05.04.0395 - Hooks on 100 cases 05.04.0394 - Hooks on 10 cases 72.32.910 - Hooks on 3 .022 length Torque angle Replacement .022" x .028" Slot quantity 2.8 mm -7° 0° 2.8 mm -7° 0° 2.8 mm 0° 11° 2.6 mm 8° 9° 3.20 mm 12° 5° 3.20 mm 12° 5° 2.6 mm 8° 9° 2.8 mm 0° 11° 2.8 mm -7° 0° 2.8 mm -7° 0° 05.04.0314 10 05.04.0314 10 05.04.0313 10 05.04.0312 10 05.04.0311 10 05.04.0321 10 05.04.0322 10 05.04.0323 10 05.04.0324 10 05.04.0324 10 5 4 3 2 1 1 2 3 4 5 15 14 13 12 11 21 22 23 24 25 Upper Lower length Torque angle Replacement .022" x .028" Slot quantity 45 44 43 42 41 31 32 33 34 35 5 4 3 2 1 1 2 3 4 5 2.8 mm -22° 0° 2.8 mm -17° 0° 2.8 mm -11° 5° 2.3 mm 0° 0° 2.3 mm 0° 0° 2.3 mm 0° 0° 2.3 mm 0° 0° 2.8 mm -11° 5° 2.8 mm -17° 0° 2.8 mm -22° 0° 05.04.0345 10 05.04.0344 10 05.04.0343 10 05.04.0341 10 05.04.0341 10 05.04.0341 10 05.04.0341 10 05.04.0333 10 05.04.0334 10 05.04.0335 10 Great Lakes’ version of the Roth prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation. 23 Great Lakes BioTru™ Archwires BioTru NiTi ™ BENEFITS APPLICATIONS CHARACTERISTICS • First archwire of choice for early- and mid-stages of treatment • Used in alignment and leveling phases with conventional brackets • Light-to-moderate forces • Force exerted is light and solid, enhancing patient comfort • Early treatment stages using round wires Intermediate stages using rectangular wires • Easier ligation without permanent deformation • Can be used in all phases of orthodontic treatment • Eases engagement into brackets due to greater flexibility • Force modules specifically calibrated for self-ligating brackets • High resiliency to deformation • Performs best in the initial stages of treatment • Pre-installed stops help prevent wire shifting during treatment • Provides lower initial load forces and increased residual forces as full shape recovery progresses • Calibrated for use with self-ligating brackets • Easier wire engagement and biocompatible force transmission • Teeth move farther and faster with lower force modules • Ideal for early and intermediate stages of treatment • Excellent shape recovery Available sizes: .012, .014, .016, .018, .020, .016x.016, .016x.022, .016x.025, .017x.025, .018x.018, .018x.025, .019x.025, .021x.025 BioTru Copper ™ • Bright surface finish and elasticity Available in Super Elastic and Thermal • Lowest power module enables integration within the same slots for misaligned and uneven cases • Unique copper alloy enhances thermal properties and flexibility • Transition temperatures of 27°C Available sizes: .013, .014, .016, .018, .014x.025, .016x.025, .018x.025 BioTru Contour ™ • Can also be used with conventional brackets • Extreme flexibility at room temperature • Full shape recovery stays active to the end • Transition temperatures of 27°C Available sizes: .013, .014, .016, .018, .014x.025, .016x.025, .017x.025, .018x.025, .019x.025 BioTru Beta Titanium* ™ • Provides force levels 45% less than equivalent stainless steel • Moderate tooth-moving force makes it ideal for mid-to-late stage treatment • Ideal for expressing torque of inclination and angulation • Excellent formability for loop placement and bends • Bendability aids in custom tipping, aligning, space closure, rotation correction, and tooth movement • High friction material • Nickel free for patients with metal allergies • Combines bendability of stainless steel with the flexibility of NiTi • Accepts folds and adjustments Available sizes: .016x.022, .017x.025, .019x.025 *Compares to TMA, a registered trademark of Ormco Corporation. 24 BENEFITS APPLICATIONS CHARACTERISTICS • Extremely high tensile strength and malleability • Ideal for detailing, finishing, and consolidating the dental arch • High luster polish and consisent surface for reduced friction • Accepts 1st, 2nd, and 3rd order folds • Biocompatible surgical stainless steel offers consistent shape and power modules • Used for extraction space closure, Class II without extraction, and anterior intrusion/anterior retraction • Smooth surface and glossy finish • Accepts intricate bends for torquing without breaking BioTru Stainless Steel ™ • Excellent for the final stages of treatment Available sizes: .012, .014, .016, .018, .020, .016x.016, .016x.022, .016x.025, .017x.025, .018x.018, .018x.025, .019x.025, .021x.025 Double Key 4 Double Key BioTru Retraction ™ T-Loop Double Key Arch Sizes: 22 mm, 24 mm, 26 mm, 28 mm, 30 mm, 32 mm, 34 mm, 36 mm, 38 mm, 40 mm, 42 mm, 44 mm Available sizes: .016x.022, .017x.025, .018x.025, .019x.025, .021x.025 • Biocompatible surgical stainless steel offers consistent shape and power modules. T-Loop is also available in Beta Titanium. • High tensile strength and malleability • Quickly and efficiently opens or closes the bite ™ • Accepts folds and adjustments • Used in sliding mechanics for space closure • Provides excellent counterforces to achieve bite and occlusal plane modifications BioTru Reverse Curve of Spee • Commonly used in combination with elastics or closed springs • Consistent activation force • Prevents molar tipping and rotation • Maintains anterior torque • Used for initial leveling and aligning • Corrects deep and open bites • Retracts flared, protruding incisors Available sizes: .012, .014, .016, .018, .020, .016x.016, .016x.022, .017x.025, .018x.025, .019x.025, .021x.025 • Three Reverse Curve of Spee (RCS) Shapes: RCS 1: Offers a deeper “rocking chair” radius exerting ideal forces to reverse the Spee Curve for severe cases of open or deep bites RCS 3: Provides a “shallower” radius and lighter force than RCS 1. Easier to ligate with gentler, more comfortable tooth movement RCS 5: Straight leg buccal segments do not toe-in the molars; they help tilt them back for anchorage purposes. Easily places Curve of Spee on the upper arch and can torque the molars buccally. Intrusion or extrusion of anterior teeth can also be accomplished. When flipped, it can be used to expand the lower arch. • High quality surface finish 25 BioTru™ NiTi Archwires SUPER ELASTIC Natural SIZE .012 .014 .016 .018 .020 .016x.016 .016X.022 .017X.025 .018X.025 .019X.025 .021X.025 UPPER (10/Pkg.) 09.15.0512 09.15.0514 09.15.0516 09.15.0518 09.15.0520 09.15.0566 09.15.0562 09.15.0575 09.15.0585 09.15.0595 09.15.0525 LOWER (10/Pkg.) 09.15.0612 09.15.0614 09.15.0616 09.15.0618 09.15.0620 09.15.0666 09.15.0662 09.15.0675 09.15.0685 09.15.0695 09.15.0625 Europa I SIZE .014 .016 .018 .020 .016X.016 .016X.022 .017X.025 .018X.025 .019X.025 .021X.025 UPPER (10/Pkg.) 09.15.0314 09.15.0316 09.15.0318 09.15.0320 09.15.0366 09.15.0362 09.15.0375 09.15.0385 09.15.0395 09.15.0325 LOWER (10/Pkg.) 09.15.0414 09.15.0416 09.15.0418 09.15.0420 09.15.0466 09.15.0462 09.15.0475 09.15.0485 09.15.0495 09.15.0425 Reverse Curve SIZE .012 .014 .016 .018 .020 .016x.016 .016X.022 .017X.025 .018X.025 .019X.025 .021X.025 UPPER (10/Pkg.) 09.23.0512 09.23.0514 09.23.0516 09.23.0518 09.23.0520 09.23.0566 09.23.0562 09.23.0575 09.23.0585 09.23.0595 09.23.0525 THERMAL Natural SIZE .014 .016 .018 .020 .016x.016 .016X.022 .017X.025 .018X.025 .019X.025 .021X.025 UPPER (10/Pkg.) 09.16.0514 09.16.0516 09.16.0518 09.16.0520 09.16.0566 09.16.0562 09.16.0575 09.16.0585 09.16.0595 09.16.0525 26 LOWER (10/Pkg.) 09.16.0614 09.16.0616 09.16.0618 09.16.0620 09.16.0666 09.16.0662 09.16.0675 09.16.0685 09.16.0695 09.16.0625 LOWER (10/Pkg.) 09.23.0612 09.23.0614 09.23.0616 09.23.0618 09.23.0620 09.23.0666 09.23.0662 09.23.0675 09.23.0685 09.23.0695 09.23.0625 BioTru™ NiTi Archwires THERMAL Europa I SIZE .014 .016 .018 .020 .016X.016 .016X.022 .017X.025 .018X.025 .019X.025 .021X.025 UPPER (10/Pkg.) 09.16.0314 09.16.0316 09.16.0318 09.16.0320 09.16.0366 09.16.0362 09.16.0375 09.16.0385 09.15.0395 09.16.0325 BioTru™ Copper BIOTRU™ COPPER 27° SIZE .013 .014 .016 .018 .014X.025 .016X.025 .018X.025 UNIVERSAL MEDIUM (10/Pkg.) 09.01.0913 09.01.0914 09.01.0916 09.01.0918 09.01.0942 09.01.0965 09.01.0985 BioTru™ Contour NiTi CONTOUR NITI 35° DAMON FORMAT SIZE .013 .014 .016 .018 .014X.025 .016X.025 .017X.025 .018X.025 .019X.025 UNIVERSAL MEDIUM (10/Pkg.) 51.10.913C 51.10.914C 51.10.916C 51.10.918C 51.10.945C 51.10.965C 51.10.975C 51.10.985C 51.10.995C 27 LOWER (10/Pkg.) 09.16.0414 09.16.0416 09.16.0418 09.16.0420 09.16.0466 09.16.0462 09.16.0475 09.16.0485 09.16.0495 09.16.0425 BioTru™ Retraction Archwires DOUBLE KEY (STAINLESS STEEL) (10/PKG.) ARCH SIZES: 22 mm, 24 mm, 26 mm, 28 mm, 30 mm, 32 mm, 34 mm, 36 mm, 38 mm, 40 mm, 42 mm, 44 mm AVAILABLE IN: .016x.022, .017x.025, .018x.025, .019x.025, .021x.025 KIT w/120 10 OF EACH SIZE .016x.022 .017x.025 .018x.025 .019x.025 .021x.025 41.99.062 41.99.075 41.99.085 41.99.095 41.99.025 4 DOUBLE KEY (STAINLESS STEEL) (10/PKG.) ARCH SIZES: 22 mm, 24 mm, 26 mm, 28 mm, 30 mm, 32 mm, 34 mm, 36 mm, 38 mm, 40 mm, 42 mm, 44 mm AVAILABLE IN: .016x.022, .017x.025, .018x.025, .019x.025, .021x.025 KIT w/120 10 OF EACH SIZE .016x.022 .017x.025 .018x.025 .019x.025 .021x.025 42.99.062 42.99.075 42.99.085 42.99.095 42.99.025 T-LOOP DOUBLE KEY (STAINLESS STEEL OR BETA TITANIUM*) (10/PKG.) ARCH SIZES: 22 mm, 24 mm, 26 mm, 28 mm, 30 mm, 32 mm, 34 mm, 36 mm, 38 mm, 40 mm, 42 mm, 44 mm AVAILABLE IN: .016x.022, .017x.025, .019x.025, .021x.025 KIT w/120 10 OF EACH SIZE Stainless Beta Titanium .016x.022 .017x.025 .019x.025 .021x.025 41.99.062 41.99.062 41.99.075 41.99.075 41.99.095 41.99.095 41.99.025 41.99.025 *Compares to TMA, a registered trademark of Ormco Corporation. 28 Archwires BioTru™ Beta Titanium* DAMON FORMAT SIZE SMALL (10/Pkg.) MEDIUM (10/Pkg.) UNIVERSAL (10/Pkg.) .016x.022 .017x.025 .019x.025 60.10.962P 60.10.975P 60.10.995P 60.10.962M 60.10.975M 60.10.995M 60.10.962 60.10.975 60.10.995 BioTru™ Stainless Steel Natural SIZE .012 .014 .016 .018 .020 .016x.016 .016X.022 .017X.025 .018X.025 .019X.025 .021X.025 UPPER (10/Pkg.) 40.20.112 40.20.114 40.20.116 40.20.118 40.20.120 40.20.166 40.20.162 40.20.175 40.20.185 40.20.195 40.20.125 LOWER (10/Pkg.) 40.20.212 40.20.214 40.20.216 40.20.218 40.20.220 40.20.266 40.20.262 40.20.275 40.20.218 40.20.295 40.20.225 Europa I SIZE .012 .014 .016 .018 .020 .016X.016 .016X.022 .017X.025 .018X.025 .019X.025 .021X.025 UPPER (10/Pkg.) 40.10.112E 40.10.114E 40.10.116E 40.10.118E 40.10.120E 40.10.166E 40.10.162E 40.10.175E 40.10.185E 40.10.195E 40.10.125E LOWER (10/Pkg.) 40.10.212E 40.10.214E 40.10.216E 40.10.218E 40.10.220E 40.10.266E 40.10.262E 40.10.275E 40.10.285E 40.10.295E 40.10.225E *Compares to TMA, a registered trademark of Ormco Corporation. 29 Great Lakes BioTru ™ Buccal Tubes Low profile for maximum patient comfort Criss-cross permanent guide Marks on the facial surface assist in bonding and positioning Color-enhanced ID Optimal functional occlusion and case finishing Malleable ball hook enhances patient comfort - avoids gingival impingement Funneled entrance helps guide the wire into buccal tube Torque in base for easy alignment BENEFITS • Advanced design and manufacturing technologies ensure maximum strength for increased clinical performance and patient comfort. • All buccal tubes have Direct Bonding Bases. APPLICATIONS • Low profile, compact design reduces occlusal interference and gingival impingement for better hygiene. • Funneled entrance helps guide the wire into the buccal tube • Utilized in posterior teeth (1st and 2nd Molars) on the vestibular faces • Buccal tubes are directly bonded to the tooth surface. • Allows easier placement of larger wires due to wider slot entrance. CHARACTERISTICS • Malleable ball hooks can be positioned away from soft tissue to avoid irritation and potential food traps Low Profile Bondable Non-Convertible Single Tubes MIM Injection Molded • .080 gauge indented foil mesh pad increases bonding strength • Torque: In base • Four distinct shapes of foil mesh pads for perfect tooth anatomy fitting AVAILABLE PRESCRIPTIONS • Roth • MBT • Edgewise/Ricketts .018" and .022" Slots • MIM in 316L low nickel surgical stainless steel Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation. 30 Auxiliaries Buccal Tubes MAXILLARY SINGLE CONVERTIBLE 3.8 .018" R. 20.13.181C BONDABLE .018" L. .022" R. 20.13.182C 20.14.181C .022" L. 20.14.182C 10° 3.8 20.13.211C 20.13.212C 20.14.212C TORQ. OFFSET mm 0° 0° 3.6 08.03.0101* 08.03.0201* 08.04.0101* 08.04.0201* 0° 8° 3.6 20.43.081* 20.43.082* 20.44.081* 20.44.082* Prescription TORQ. OFFSET mm Roth -10° 8° MBT -14° Prescription Edgewise / Ricketts 20.14.211C SINGLE NON-CONVERTIBLE - .018" R. BONDABLE .018" L. .022" R. .022" L. Roth -10° 8° 3.6 08.03.0105* 08.03.0205* 08.04.0105* 08.04.0205* MBT -14° 10° 3.6 08.03.0107* 08.03.0207* 08.04.0107* 08.04.0207* Prescription TORQ. OFFSET mm MBT -20° 0° 3.8 .018" R. 20.13.304C BONDABLE .018" L. .022" R. 20.13.303C 20.14.304C .022" L. 20.14.303C Roth -25° 5° 3.8 20.13.454C 20.13.453C 20.14.453C Prescription TORQ. OFFSET mm Edgewise / Ricketts 0° 0° 0° -20° MANDIBULAR SINGLE CONVERTIBLE 20.14.454C SINGLE NON-CONVERTIBLE MBT Roth .018" R. BONDABLE .018" L. .022" R. .022" L. 3.6 08.03.0301* 08.03.0401* 08.04.0301* 08.04.0401* 5° 3.6 20.43.054* 20.43.053* 0° 3.6 08.03.0308* 08.03.0408* 08.04.0308* 20.44.054* 20.44.053* 08.04.0408* -25° 0° 3.6 20.43.404* 20.43.403* 20.44.404* 20.44.403* -25° 5° 3.6 08.03.0310* 08.03.0410* 08.04.0310* 08.04.0410* * For bondable tubes, the reference code must end with the option of mesh pad base type: (B) Big Foot. (L) Long. (C) anatomic or (X) Small BONDABLE BASES FOR NON-CONVERTIBLE TUBES (CONVERTIBLE TUBES ONLY COME IN ANATOMIC) ANATOMIC 5 mm x 3 mm LONG 7 mm x 2.8 mm SMALL 4.3 mm x 3 mm BIGFOOT 8 mm x 3.5 mm Great Lakes’ version of the Roth prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation. 31 Auxiliaries Ball Hooks ITEM ITEM # (10/Pkg.) Bi-drectional Bracket Hook Bracket Ball Hook Bi-drectional Bracket Hook 01.00.0011 01.00.0009 Bracket Ball Hook Stops SIZE DIAMETER ITEM # (10/Pkg.) 2 mm 0.13 mm 01.00.0002 3 mm 0.13 mm 01.00.0006 NiTi Springs OPEN SIZE ITEM # (3/Pkg.) .010X.030 - 7" 07.10.2602 .012X.030 - 7" 07.10.2702 .014X.030 - 7" 07.10.2802 .014X.045 - 7" 07.10.3002 DISTALIZATION SIZE ROLL LENGTH ITEM # (10/Pkg.) .010X.045 38 cm 07.09.3107 .012X.045 38 cm 07.09.2907 CLOSED / RETRACTION 32 SIZE FORCE SIZE ITEM # (10/Pkg.) .010X.030 Light 6 mm 07.11.4105 .010X.030 Light 9 mm 07.11.4205 .010X.030 Light 12 mm 07.11.3405 .010X.030 Light 15 mm 07.11.3505 .011X.030 Medium 6 mm 07.11.3605 .011X.030 Medium 9 mm 07.11.3705 .011X.030 Medium 12 mm 07.11.3805 .011X.030 Medium 15 mm 07.11.3905 .012X.030 Heavy 6 mm 07.11.4005 .012X.030 Heavy 9 mm 07.11.4305 .012X.030 Heavy 12 mm 07.11.3205 .012X.030 Heavy 15 mm 07.11.3305 Accessories Ligatures ELASTIC CHAIN AVAILABLE IN 1 M OR 4.5 M ROLLS COLORS COLORS MAGENTA PEARLY BLUE DESERT BLUE PINK BLACK TURQUOISE HOT PINK PEARLY GREEN TRANSPARENT METALLIC BLUE METALLIC RED LIGHT BLUE FLUORESCENT ORANGE FLUORESCENT PINK FLUORESCENT BLUE NEON GREEN DARK GREEN NAVY BLUE GREEN YELLOW ORANGE WHITE METALLIC PURPLE PURPLE ROYAL BLUE RED METALLIC GRAY RED RUBY INTRAORAL ELASTIC ITEM # COLOR FORCE SIZE (100/Pkg.) 00.90.184 00.90.185 00.90.186 00.90.187 00.90.189 00.90.188 00.90.190 00.90.191 00.90.193 00.90.192 00.90.194 00.90.195 Natural Natural Natural Natural Natural Natural Natural Natural Natural Natural Natural Natural Light Light Light Light Medium Medium Medium Medium Heavy Heavy Heavy Heavy 1/8" 1/4" 3/16" 5/16" 1/8" 1/4" 3/16" 5/16" 1/8" 1/4" 3/16" 5/16" SEPARATORS ITEM # (1000/Pkg.) 00.90.202 STICK TIES ITEM # 00.90.135R 00.90.136R 00.90.137R 00.90.139R 00.90.140R 00.90.141R 00.90.144R 00.90.145R 00.90.146R 00.90.147R 00.90.149R 00.90.150R 00.90.152R 00.90.155R 33 COLOR (520/Pkg.) RED STICK TIE R METALLIC BLUE STICK TIE R GRAY STICK TIE R YELLOW STICK TIE R BLACKBERRY STICK TIE R LIGHT GREEN STICK TIE R NAVY BLUE STICK TIE R BLACK STICK TIE R MAGENTA STICK TIE R PINK STICK TIE R WHITE STICK TIE R GREEN STICK TIE R ORANGE STICK TIE R TRANSPARENT STICK TIE R Accessories Adhesives Light Bond™ Kit Intended for use as a light cure bracket and lingual retainer adhesive. Bonds to any enamel, porcelain, composite, or metal surface when properly conditioned. Temperature Limitation: Store at room temperature not to exceed 86°F or can be refrigerated 36-46°F. (Refrigeration will prolong the shelf life of Light Bond™. Allow product to reach room temperature prior to use.) Includes: (4) 20 g Push Syringes, 23 g Liquid Etchant, 6 ml Assure® Plus Bonding Resin, Mixing Pad, Spatulas, and Brushes. 065-042 Light Bond™ Kit Reliance Flow Tain® Composite Flow Tain® is used for fabricating bonded lingual retainers and bonding brackets. This flowable light cure material is smooth when cured, reducing wear and enhancing patient comfort. Tip dispensers provide better control without slumping. Includes: (1) 1.5 g Syringe and (10) 22 Gauge Tips. 065-040 Reliance Flow Tain® Composite Reliance Band-Lok™ 065-026 Flouride-releasing, two-paste glass ionomer band cement. Better adhesion to enamel and band surfaces is achieved, reducing washout and preventing loose bands. No unpleasant aftertaste. Consistent mix viscosity. Paste A with Fluoride (6 g) 065-026 Paste B (6 g) 065-001 065-001 Reliance Light Bond™ Visible Light Cure Sealant & Bracket Bonding System Incorporates a smooth tacky paste so that bracket flotation is virtually impossible. Bonds all plastic, ceramic, sapphire, and metal brackets to enamel and porcelain surfaces. Includes: (4) 5 g Filled Syringes, (2) 3 cc Light Cure Sealant Resins, (1) 24 g Etching Agent, and Mixing Pads. Reliance Light Bond™ Visible Light Cure Sealant & Bracket Bonding System 065-032 Reliance First & Final The first prophy pumice specially formulated for orthodontic use. Conveniently packaged in cups for individual patient use and pre-mixed - no messy mixing with water. Pumices better and rinses cleaner for better bond strength. No flavoring, flourides, or oils to inhibit and weaken the bond. Can also be used for polishing the enamel after debonding. Reliance First & Final (200/pkg.) 065-041 Reliance Enhance® Adhesion Booster Increases the adhesion of any bonding agent to flourosed, hypo-calcified or deciduous enamel to acrylic, composite, or metal surfaces. Ideal for any enamel surface where maximum adhesion is required and for enamel close to the gingiva, where minor surface moisture may reduce bond strength. Part A (3 cc) 065-034 Part B (3 cc) 065-035 065-034 065-035 34 Accessories Reliance Therma-Cure® Heat curable lab adhesive for metal, ceramic, and plastic brackets. 065-033 Reliance Therma-Cure® (5 g) Reliance Maximum Cure® Sealant 065-021 065-022 Flouride-releasing, chemical-curing sealant system. No curing light required. The whole labial tooth surface can be sealed. Increases adhesive strength to enamel. Requires refrigeration. Part A with Fluoride (7 g) 065-021 Part B (7 g) 065-022 Reliance Excel® with Fluoride Excel®’s three minute set time is ideal for bonded Herbsts*, bonded RPEs and indirect bonding. Its thin viscosity will flow easily onto bracket base, pad, or acrylic appliance. Includes: 12 g Catalyst Paste A, 12 g Base Paste B, 9 g Etching Agent, Spatulas, Mixing Brushes, Pallet Mixing Dish, and Pad. Reliance Excel® with Fluoride 065-037 Paste A with Fluoride (12 g) 065-038 Paste B (12 g) 065-039 065-038 065-039 Reliance Phase II® 065-004 065-019 065-018 Sealant and bonding system for direct bonding. Sealant reduces decalcification. Strong enough to bond molar attachments, but is easily removed in one piece. 065-004 Liquid Etching Agent (9 g) 1-½" Dispoable Brushes (50/pkg.) 065-018 Spatulas (5/pkg.) 065-019 Mixing Pads (3/pkg.) 065-020 065-020 Bite Ramps Mini Mold Starter Kit Mini Mold Tips precisely cast a light-cured resin appliance in seconds. It does the job quickly and easily. Just fill the mold, place on tooth, and cure. Select from 10 different treatment aids. Kit includes: (3) Habit Control, (3) Anterior Bite Ramp -5 mm, (3) Anterior Bite Ramp-3 mm, (3) Posterior Molar Pad, (3) Wire Bonder (small), (3) Wire Bonder (large), (3) Button Bonder, (3) Bracket Bonder, (3) Tube Bonder, (3) Cuspid Bite Ramp, and (2) Bonder Handles. Mini Mold Starter Kit 195-030 Bite Ramp Bonder Forms a bite opening ramp on the lingual of the upper incisors: Used to adjust the occlusion as needed. Available in 5 mm and 3 mm. Includes: (8) Mini Mold Ramp Tips and (1) Bonder Handle. 195-031 3 mm (8/pkg.) 5 mm (8/pkg.) 195-032 *Herbst is a registered trademark of Dentaurum, Inc. 35 Notes 36 Great Lakes Bracket Catalog 2016 Exceptional Quality. 200 Cooper Avenue PO Box 5111 Tonawanda, NY 14151-5111 1.800.828.7626 (U.S. & Canada) 716.871.1161 (Worldwide) Email: bracketsales@greatlakesortho.com www.GreatLakesBrackets.com SMPP580Rev031716 Manufactured by Aditek® Orthodontics Outstanding Value.
Similar documents
mu04feb16-Amplaid A137
Peltor noise enclosures ADC noise enclosures Patient handswitch Power cable Instruction Manual BC vibrator, B71 Single insert phone Operator monitor phones Operator microphone Goose-neck operator m...
More informationHustler® Raptor® Parts Manual
This Parts Manual provides a complete parts listing for the unit. Use this manual when ordering parts. Illustrations used were current at the time of printing, but subsequent production changes may...
More information