IntelliCon - AR Thomson Group
Transcription
IntelliCon - AR Thomson Group
‘Smart ways to save energy’ IntelliCon ® INSTALLATION MANUAL Intellidyne, LLC 90 Pratt Oval Glen Cove, NY 11542 516-676-0777 www.Intellidynellc.com 3/6/2006 Air Conditioning General Instructions: General Wiring Instructions 2 Stage Air Cooled Air Conditioners Heat Pump System York Heat Pumps Typical Packaged HVAC System Typical 24vac Split A/C Air Handler Typical 208/230vac Split A/C Air Handler AC or CAC in Outdoor Condensing Section Trane with Honeywell W973 Logic Panel Trane “Voyager” with Interface Board Trane “Voyager” without Interface Board Honeywell T775 Applications 2-1 2-1 2-2 2-2 2-3 2-4 2-4 2-5 2-6, 7, 8 2-9 2-10, 11 2-12 HEATING Beckett HeatManager Honeywell L7124A, C or L7148A Honeywell L7124U Honeywell L7148F Honeywell L7224U Electronic Aquastat Honeywell L8124A, C Honeywell L8124E Honeywell L8124G, L Honeywell L8148A Honeywell L8148E Honeywell L8148J Honeywell L8151A Honeywell R7184A, B, P, U (Line Voltage Controller) Honeywell R7184A, B, P, U (Low Voltage Controller) Honeywell R7184A, B, P, U “REVISION 5” Model Honeywell R8182D Honeywell R8182E Honeywell R8182F Honeywell R8184G, K, L, N Cad Cell Relay Honeywell R8184M, P Honeywell R8285D Riello Model 40F5 3-1 3-2 3-3 3-4 3-5 3-6 3-7 3-8 3-9 3-10 3-11 3-12 3-13 3-14 3-15 3-16 3-17 3-18 3-18 3-19 3-20 Cad Cell Relays General Instructions 3-21 Honeywell R8184G, K, L, N Honeywell R8184M, P Honeywell R7184A, B, P, U 3-22 3-22 3-23 5/30/2006 3 HEAT TIMER CHS/CHW with Mechanical Heat Timer CHS/CHW with MPC Heat Timer LCH with Mechanical Heat Timer LCH with MPC Heat Timer LCS with Mechanical Heat Timer LCS with MPC Heat Timer 3-25 3-26 3-27 3-28 3-29 3-30 HW with Riello Model 40F5 3-31 Honeywell Aquastats (see Beckett HeatManager also) L7124A, C L7124U L7148F L7224U Electronic Aquastat L8124A, C L8124E L8124G, L L8148A L8148E L8148J L8151A R7184A, B, P, U, (Line Voltage Controller) R7184A, B, P, U, (Low Voltage Controller) R7184A, B, P, U, “REVISION 5” Model R8182D R8182E R8182F Honeywell R8184G, K, L, N Cad Cell Relay Honeywell R8184M, P Honeywell R8285D Riello Model 40F5 3-32 3-33 3-34 3-35 3-36 3-37 3-38 3-39 3-40 3-41 3-42 3-43 3-44 3-45 3-46 3-47 3-48 3-49 3-49 3-50 3-51 Fireye Flame Safeguard Controls General Instructions CHS or CHW with: 24CJ5, Model 3010, 3011 24CU6, Model 1062, 1063 24CF6, Model 1010, 1011 25CU6, Model 5056 26CF6, Model 5023 24CJ5, Model 5015 25CU6 Model 3010, 3011 26CF6 Model 5022 EP (D)160, EP161, EP(D)170 Modular “M” Series 3-52 3-53 3-54 3-55 3-56 3-57 3-58 3-59 3-60 3-61 3-62 3/6/2006 UVM-1 UVM-1D, 1F, 2A, 3 or TFM -1D, 1F, 2A, 3 UVM-2A or TFM-2A UVM-3 or TFM-3 3-63 3-64 3-65 3-66 LCH or LCS with: 24CJ5, Model 3010, 3011 24CU6, Model 1062, 1063 26CF6, Model 1010, 1011 25CU6, Model 5066 25CF6, Model 5023 24CJ5 Model 5015 25CU6 Model 5065 26CF6, Model 5022 EP (D)160, EP161, EP(D)170 Modular “M” Series UVM-1 UVM-1D, 1F, 2A, 3 or TFM -1D, 1F, 2A, 3 UVM-2A or TFM-2A UVM-3 or TFM-3 3-67 3-68 3-69 3-70 3-71 3-72 3-73 3-74 3-75 3-76 3-77 3-78 3-79 3-80 Honeywell Flame Safeguard Controls General Instructions CHS or CHW with: R4140G, L, M or R4150A, C, X R4795A, D R7795A, B, C, D RM7800 or RM7840E, G, L, M 3-81 3-82 3-83 3-84 3-85 LCH with: AO Smith DuraMax Models DB/DW 720-1810 3-86 LCH or LCS with: R890E, F, G R4140G, L, M or R4150A, C, X R4795A, D R7795A, B, C, D RM7800 or RM7840E, G, L, M RM 7895 3-87 3-88 3-89 3-90 3-91 3-92 Refrigeration RU Wiring Precautions RU Wiring Diagrams 4-1 4-2 3/6/2006 Pressure Control Operated, 115vac power/control Pressure Control Operated, 220vac power/ control Pump-down System, 220vac power/control Pump-down System, 220vac power/24vac control Pump-down System, 220vac power/115vac control 4-2 4-3 4-5 4-6 4-7 FA/CFA FA with Honeywell R8184G, K, L or N Cad Cell Relay FA with Honeywell R8184 M or P Cad Cell Relay FA with Honeywell R7184A, B, P, U Electronic Oil Primary FA with Honeywell R7184A, B, P, U “Series 5 Relay FA with Typical Residential Warm Air Furnace FA with Riello Burner and Relay Module CFA with Typical Packaged HVAC Unit 6 3/21/2007 5-1 5-1 5-2 5-3 5-4 5-5 5-6 AIR CONDITIONING CAUTION: Read and follow these general instructions and the instructions that are packed with the IntelliCon® Model AC or CAC. Failure to follow these instructions could result in damage to the system or cause a hazardous condition. General Instructions: The IntelliCon® Models “AC” and “CAC” are connected in the control circuit so that the call for the compressor to run is interrupted between the thermostat and the compressor. These connections are at the “Y” terminals on the unit low voltage control connection board. These connections are made as follows: 1. Remove the compressor “call” wire from the “Y” terminal. 2. Connect the IntelliCon® ‘YELLOW” wire to this wire with a wire nut. 3. Connect the IntelliCon® “RED” wire to the “Y” terminal. The IntelliCon® Economizer is now connected in the control circuit in series after the thermostat but before any and all safety controls and the compressor. Two Stage Air Cooled Air Conditioning Systems; Some two stage cooling systems are designed to have the condenser fan energized with the first stage compressor, while the second condenser fan is energized on outdoor air temperature or condenser coil temperature. When the IntelliCon® CAC is in the “Economizing” mode delaying the first stage compressor, the second stage compressor could be energized leaving it to run without the condenser fan running. This could result in the second stage cooling locking out on high pressure safety and not available for cooling when needed. This is corrected by wiring the second stage compressor contactor to the first stage condenser fan relay. Be sure to check electrical voltage and phasing. After mounting and wiring, test the operation of the IntelliCon® CAC and condenser fans before leaving the installation. Continued on next page 5/31/2006 1 HEAT PUMP UNITS (All Manufacturers) On most systems the IntelliCon® AC or CAC units can be wired into the 24vac control circuit at the “Y” terminal in the air handler. When wired this way, the AC or CAC is in the circuit when in the cooling mode or heating mode. It is extremely important to be sure that the system you are installing on is wired this way. Connect the AC or CAC as you normally would at the “Y” terminal. York Heat Pumps: Older York Heat Pump systems were wired so that the thermostat opened the 24vac “COMMON” instead of the 24vac “HOT”. To connect the IntelliCon® Economizers in the 24vac control circuit, the IntelliCon® “GREY” wire must be connected to the 24vac “HOT”. This is because the thermostat compressor wire is the 24vac “COMMON” instead of the normal 24vac “HOT”. 2-2 3/06/06 L2 L3 Single or Three Phase Line Power Supply L1 From Thermostat Unit Control Transformer WHITE VIOLET R C GREY RED G YELLOW W DWG. # Y TAPE OFF INDIVIDUALLY BROWN BLACK BLUE IntelliCon CAC DWG# Break Connection Here DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne DATE IntelliCon CAC with Typical Packaged HVAC Unit 3/06/06 2-3 TAPE OFF INDIVIDUALLY IntelliCon Low Voltage Terminal Board R C G Y R C L1 L2 BLACK VIOLET BROWN RED YELLOW W Break Connection Here Unit Transformer 230vac/24vac To T-Stat 208/230 vac 1 Phase To Condensing Section DWG. # BLUE GREY WHITE DWG# AIR HANDLING UNIT L1 L2 208/230vac Power To IntelliCon TAPE OFF INDIVIDUALLY IntelliCon AIR HANDLING UNIT BLACK BLUE BROWN GREY Low Voltage Terminal Board R C RED G Y R C Unit Transformer 230vac/24vac To T-Stat 208/230 vac 1 Phase L1 L2 2-4 3/06/06 W L2 YELLOW Break Connection Here VIOLET L1 DATE: 24vac Power To IntelliCon CUSTNAME DWGDESC Intellidyne Air Handling Unit 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 DATE IntelliCon AC or CAC with Typical WHITE To Condensing Section DATE: DWG# CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne DATE IntelliCon AC or CAC with Typical Outdoor Condensing Section DWG. # TAPE OFF INDIVIDUALLY IntelliCon BLUE BLACK BROWN 24vac From Thermostat Y C YELLOW WHITE VIOLET RED Break Connection Here GREY COMPRESSOR CONTACTOR L2 L1 208/230 vac 1 Phase L1 L2 T1 T2 HIGH PRESSURE SWITCH LOW PRESSURE SWITCH TO COMPRESSOR TYPICAL OUTDOOR CONDENSING SECTION 3/06/06 2-5 Trane Units: With Honeywell W973 Logic Panel Units with Honeywell W973 Logic Panel installed CANNOT have the IntelliCon® CAC Economizer wired at the compressor contactor. A low pressure bypass timer is in series in the safety control circuit with the high pressure safety switch, low pressure safety switch, etc. that will cause the compressor to lockout on a reset relay if the compressor does not start immediately upon the call for cooling from the W973 Logic Panel. The low voltage terminal board in these units also cannot be used because it is 20 volts DC. To connect the IntelliCon® CAC Economizer to systems using the Honeywell W973 Logic Panel, follow the factory authorized directions below and the wiring diagrams following pages. The IntelliCon® CAC module can be wired at “COOL 1” of the W973. 1. Remove the wire from the load side of the NORMALLY OPEN contact of “COOL 1” 2. Connect the YELLOW wire to this wire and connect the RED wire to the NORMALLY OPEN contact of “COOL 1” Properly connected, upon a ramping of the DC Voltage at the W973 from the Space Transmitter, “Cool 1” will energize but will be routed through the IntelliCon® CAC first. 2-6 3/06/06 TAPE OFF INDIVIDUALLY DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne DATE Honeywell W973 Logic Panel Using 24vac Control Circuit R DWG# IntelliCon CAC DWG. # BLACK VIOLET BROWN BLUE RED WHITE YELLOW GREY W973 LOGIC PANEL 2 HEAT 1 3 COOL 3 HEAT 2 COOL 1 MOD - HEAT WH R C T T1 MOD - COOL BH RH 3 UNIT TRANSFORMER BC RC STAT SENSOR Break Connection Here 24VAC C +20 H N 4 2 5 1 TR TR WC ECONO W B Y R TO 24vac COMPRESSOR CIRCUIT L1 L2 120VAC POWER N H 3/06/06 2-7 TAPE OFF INDIVIDUALLY DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne DATE Honeywell W973 Logic Panel Using 120vac Control Circuit R DWG# IntelliCon CAC DWG. # BLUE VIOLET GREY BLACK RED WHITE YELLOW BROWN W973 LOGIC PANEL 2 HEAT 1 3 COOL 3 HEAT 2 COOL 1 MOD - HEAT WH T T1 MOD - COOL BH RH 3 BC RC STAT SENSOR Break Connection Here 24VAC C +20 H N 4 2 5 1 TR TR WC ECONO W B Y R TO 120vac COMPRESSOR CIRCUIT 120VAC POWER N H 2-8 3/06/06 TRANE “VOYAGER” WITH THERMOSTAT INTERFACE BOARD These units utilize a “normal” electronic or electro-mechanical thermostat. Connect the IntelliCon® CAC to the Low Voltage Terminal Board in the Trane unit as follows: IMPORTANT; The following directions represent only one of the many variations of the Low Voltage Wiring Schematic supplied with the Trane Thermostat Interface Board due to changes in the Trane Voyager unit. CONSULT THE UNITS THERMOSTAT INTERFACE BOARD WIRING DIAGRAM FOR THE PROPER TERMINALS. 1. Remove the thermostat “Y1” wire from terminal on the low voltage terminal board (LTB). 2. Connect the YELLOW wire from the IntelliCon® CAC to the wire you just removed. 3. Connect the RED wire from the IntelliCon® to the terminal where you removed the “Y1” wire from the thermostat on the low voltage terminal board (LTB). 3/06/06 2-9 Trane “VOYAGER” WITHOUT THERMOSTAT INTERFACE BOARD These units CANNOT have the IntelliCon® CAC wired at the low voltage terminal board. Without the Thermostat Interface Board, a Trane “ZONE SENSOR” is used instead of a conventional thermostat and utilizes a DC voltage ramp. The IntelliCon® CAC MUST be wired at compressor #1 contactor as shown in the diagram. Follow the same directions if the unit has 2 compressors. Figure “A” shows the factory wiring of compressor #1 contactor. Figure “B” shows how to wire in the IntelliCon® CAC using a 200 ohm, 10 watt resistor. This resistor must be used to complete a voltage circuit back to the UPC board or the UPC board will lock the compressor out, requiring a manual reset of the unit. To connect the IntelliCon® CAC to this configuration use the wiring diagrams on the following page. 2-10 3/06/06 3/06/06 2-11 Fig. A IntelliCon Fig. B ® DWGDESC CUSTNAME TAPE OFF INDIVIDUALLY 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne or L7148A Oil Electronic Aquastat DATE: DATE Beckett HeatManager with Honeywell L7124A,C DWG# HeatManager DWG. # BLUE GREY VIOLET WHITE BLACK L1 120 H VAC N T L2 T TYPICAL HONEYWELL L7124A,C or L7148A C1 ZC YELLOW B2 C2 ZR B1 BROWN RED To Line Voltage Oil Burner Relay Break Connection Here 3/06/06 3-1 ® DWGDESC CUSTNAME TAPE OFF INDIVIDUALLY 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne Universal Oil Electronic Aquastat DATE: DATE Beckett HeatManager with Honeywell L7124U DWG# HeatManager DWG. # BLUE GREY VIOLET WHITE BLACK L1 120 H VAC N T L2 T TYPICAL HONEYWELL L7124U C1 ZC YELLOW B2 C2 ZR B1 BROWN RED To Line Voltage Oil Burner Relay 3-2 3/06/06 Break Connection Here N 120 VAC H L1 C2 TYPICAL R L7148F NOTE: Not All Terminals Shown S1 R B1 HONEYWELL To Boiler Sensor L2 L1X C S2 L1 B2 L2 L2X C G R C1 Break Connection Here YELLOW BLUE GREY WHITE DWG. # RED ® DATE Electronic Aquastat DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne To 24vac Burner Control DWG# BROWN VIOLET BLACK HeatManager TAPE OFF INDIVIDUALLY Beckett HeatManager with Honeywell L7148F 3/06/06 3-3 3-4 TO LINE VOLTAGE OIL BURNER RELAY TAPE OFF INDIVIDUALLY VIOLET GREY BLUE YELLOW Break Connection Here RED HeatManager BROWN WHITE BLACK ZC B1 C1 B2 C2 L2 L1 ZR DWG. # (Not All Terminals And Wiring Shown) TYPICAL L7224U 1 2 T3 T L7224U Oil Electronic Aquastat Controller DATE: CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne Beckett HeatManager with Honeywell DATE: DWGDESC CUSTNAME TAPE OFF 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne Beckett HeatManager with Honeywell L8124A,C INDIVIDUALLY DWG# HeatManager DWG. # BLUE GREY VIOLET 120VAC BLACK L2 L1 T T WHITE G TYPICAL HONEYWELL L8124A,C TO LINE VOLTAGE OIL BURNER RELAY OR GAS VALVE C1 B2 C2 ZR ZR B1 BROWN RED YELLOW BREAK CONNECTION HERE 3/06/2006 3-5 DATE: DWG# DWGDESC CUSTNAME HeatManager 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 TAPE OFF INDIVIDUALLY Intellidyne DATE Beckett HeatManager with Honeywell L8124E BLUE DWG. # BROWN VIOLET TV T Z TYPICAL HONEYWELL L8124E C1 C2 GREY BLACK B1 B2 L1 L2 G H N G YELLOW RED TO 24VAC GAS VALVE 120VAC 3-6 WHITE DATE: DWG# DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 HeatManager Intellidyne TAPE OFF INDIVIDUALLY DATE Beckett HeatManager with Honeywell L8124G,L BLUE DWG. # GREY VIOLET TV T Z TYPICAL HONEYWELL L8124G,L BROWN B1 B2 C2 BLACK C1 L1 L2 G H N G WHITE YELLOW RED TO LINE VOLTAGE OIL BURNER RELAY OR GAS VALVE 120VAC 3/06/06 3-7 DATE: DWGDESC DWG# HeatManager CUSTNAME TAPE OFF INDIVIDUALLY 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne DATE Beckett HeatManager with Honeywell L8148A BLUE DWG. # GREY VIOLET WHITE BLACK G L1 L2 T T G 120 VAC H N TYPICAL HONEYWELL L8148A BROWN YELLOW C1 TO LINE VOLTAGE OIL BURNER RELAY OR GAS VALVE 3-8 3/06/2006 RED C2 B1 B2 DATE: DWGDESC CUSTNAME DWG# HeatManager 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 TAPE OFF INDIVIDUALLY Intellidyne DATE Beckett HeatManager with Honeywell L8148E BLUE DWG. # BROWN VIOLET TV W T Z TYPICAL HONEYWELL L8148E C1 C2 GREY BLACK B1 B2 L1 L2 H N YELLOW WHITE RED TO 24VAC GAS VALVE 120VAC 3/06/06 3-9 DATE: DWG# DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 HeatManager Intellidyne TAPE OFF INDIVIDUALLY DATE Beckett HeatManager with Honeywell L8148J BLUE DWG. # BROWN VIOLET TV W TP Z T TYPICAL HONEYWELL L8148J C1 C2 GREY BLACK B1 B2 B3 L1 L2 G H N G YELLOW RED TO 24VAC GAS VALVE 120VAC 3-10 3/06/06 WHITE DATE: DWG# DWGDESC HeatManager CUSTNAME TAPE OFF INDIVIDUALLY 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne DATE Beckett HeatManager with Honeywell L8151A BLUE DWG. # GREY VIOLET WHITE BLACK G L1 L2 T T G 120 H VAC N TYPICAL HONEYWELL L8151A C1 ZC YELLOW B2 C2 ZR B1 BROWN TO LINE VOLTAGE OIL BURNER RED RELAY OR GAS VALVE 3/06/06 3-11 3-12 3/06/06 NOTE: Not All Terminals Shown TYPICAL HONEYWELL R7184 T CAD CELL VALVE IGNITOR BURNER MOTOR L2 L1 LIMIT Break Connection Here B1 T W T B2 AQUASTAT CONTROLLER T C2 C1 R THERMOSTAT CIRCULATOR PUMP DWG. # RED YELLOW BROWN WHITE BLACK DWG# VIOLET GREY BLUE ® DATE Electronic Oil Primary DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne TAPE OFF INDIVIDUALLY 120vac HeatManager L2 L1 Beckett HeatManager with Honeywell R7184A,B,P,U Data Port Red Reset Button Diagnostic Light Typical Honeywell R7184 SIDE VIEW Burner Motor L1 VALVE DWG. # NOTE: In this application the BROWN wire MUST be used instead of the GREY wire. IGNITOR L2 LIMIT DWG# Intellidyne DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 CONSTANT 120 VAC TAPE OFF INDIVIDUALLY DATE R7184A,B,P,U Electronic Oil Primary When Aquastat Is Wired 24VAC Typical Honeywell R7184 BOTTOM VIEW May Require A Piggyback Connector BROWN Typical Honeywell L4006A Aqustat WHITE BLACK T GREY BLUE VIOLET YELLOW T Break Connection Here RED HeatManager Diagram "C" Beckett HeatManager with Honeywell CAD CELL 3-13 3-14 3/06/06 75 10 4A 8 1 R7 T T3 2 1 YELLOW GREY Typical Honeywell L4006A Aqustat Break Connection Here RED DWG. # WHITE BLACK VIOLET BROWN BLUE HeatManager DWG# Intellidyne DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 CONSTANT 120 VAC TAPE OR WIRENUT INDIVIDUALLY DATE R7184A,B,P,U "SERIES 5" Electronic Oil Primary When Aquastat Is Wired 24VAC Alarm Terminals Thermostat Terminals EnviroCom Terminals Data Port 5 Delay Time Dip Switch Red Reset Button Diagnostic Light Typical Honeywell R7184 SIDE VIEW R7 18 4A ,B ,P ,U Beckett HeatManager with Honeywell DATE: DWG# DWGDESC HeatManager CUSTNAME Tape Off Individually 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne DATE Beckett HeatManager with Honeywell R8182D Blue Grey White INSTRUCTIONS Remove the existing Yellow wire from the bottom of the HI Limit Setting switch. Insert the HeatManager "YELLOW" wire into the wire hole. Connect the HeatManager "RED" wire to the Yellow wire that was removed. DWG. # Violet Brown Black L1 L2 T 120 H VAC N T B B Safety Switch DIF H I Reset Button L O Circuit Board Connection ZR ZC Yellow C1 Red F F B1 B2 C2 Yellow wire from bottom of HI Limit Setting 3/06/06 3-15 DATE: DWG# DWGDESC HeatManager CUSTNAME Tape Off Individually 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne DATE Beckett HeatManager with Honeywell R8182E Blue Grey White INSTRUCTIONS Remove the Yellow wire from the bottom terminal of the Aquastat Switch. Connect the HeatManager "YELLOW" wire to this terminal. Connect the HeatManager "RED" wire to the Yellow wire that was removed DWG. # Violet Brown Black L1 L2 T 120 H VAC N T Safety Switch Reset Button Aquastat Switch Circuit Board Connection ZC Yellow C1 Red F F B1 Yellow wire from bottom of Aquastat Switch 3-16 3/06/06 ZR B2 C2 DATE: DWG# DWGDESC HeatManager CUSTNAME Tape Off Individually 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne DATE Beckett HeatManager with Honeywell R8182F Blue Grey White INSTRUCTIONS Remove the existing wire from the bottom of the HI Limit Setting switch. Insert the HeatManager "YELLOW" wire into the wire hole. Connect the HeatManager"RED" wire to the Yellow wire that was removed. DWG. # Violet Brown Black L1 L2 T 120 H VAC N T B B Safety Switch Reset Button Aquastat Switch H I L O Circuit Board Connection Yellow C1 Red F F B1 B2 C2 Wire from bottom of HI Limit Setting 3/06/06 3-17 3-18 3/06/06 120VAC ORANGE WHITE BLACK WHITE BLACK TYPICAL HONEYWELL R8184G,K,L or M VIOLET BROWN BLUE HeatManager F F T T Break Connection Here OPERATING AQUASTAT BLACK BLACK CAD CELL EYE 120VAC ORANGE WHITE WHITE R DWG. # TYPICAL HONEYWELL R8184M, P F F G Y C W DWG# DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne CAD CELL EYE Break Connection Here RED YELLOW RED GREY YELLOW VIOLET BROWN BLUE HeatManager TAPE OFF INDIVIDUALLY DIAGRAM "B" Beckett HeatManager with Honeywell R8184M or P Cad Cell Relay GREY TAPE OFF INDIVIDUALLY DIAGRAM "A" Beckett HeatManager with Honeywell R8184G, K, L or N Cad Cell Relay DATE R 1 1 C 6 NO 5 2 2 Y FRS 3 1K-2 G Motor BVS W R 1K-1 Motor Damper 4 COIL 4 24V Transformer Secondary Primary 3 Circulator 120/60/1 Power Supply NC 1K-3 High Limit 4 1 THERMOSTAT Service Switch Fused Disconnect Switch L1 TH TR C L2 RED YELLOW BLUE GREY BREAK CONNECTION HERE WHITE DWG. # DWG# DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne TAPE OFF INDIVIDUALLY BROWN VIOLET BLACK HeatManager DATE Beckett HeatManager With Honeywell R8285D Relay/Transformer Package When Used On Boilers 3-19 120VAC POWER 3-20 3/06/06 H N Electronic OR Mechanical Operating Aquastat VIOLET GREY BLUE N L AUX DWG. # BURNER REILLO Addiitional Wire Added For Electronic Shutter DWG# DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne DATE (if experiencing voltage feedback from burner on IntelliCon "RED" Wire) Field Supplied 120VAC Coil Single Pole SingleThrow Relay RED YELLOW Break Connection Here BLACK BROWN WHITE HeatManager TAPE OFF INDIVIDUALLY Beckett HeatManager with Riello 40F5 Burner Wiring the IntelliCon® HW or LCH with A Cad Cell Relay A boiler with the operating limit control (aqua-stat) wired to “T T” on the cad cell relay does not have to be rewired to accommodate the installation of the Model HW or LCH even though the internal transformer of the cad cell relay is not accessible for 24vac control wiring purposes. DO NOT connect the HW or LCH control circuit at the orange lead on the cad cell relay as the burner will go off on “safety”. Wiring the HW or LCH control circuit at the black lead of the cad cell relay will remove power to the cad cell relay transformer. If the “TT” terminals have a “jumper” across them, then the operating aqua-stat is line voltage and the HW or LCH can be wired 115vac for the power and the control circuit. Below are the factory authorized wiring diagrams to accomplish the installation: Diagram “A”: Honeywell R8184 G, K, L, N Diagram “B”: Honeywell R8184 M, P Diagram “C”: Honeywell R7184 A, B, P, U Diagram “D”: Honeywell R7184 A, B, P, U, “REVISION 5” 3/06/06 3-21 3-22 3/06/06 120VAC ORANGE WHITE BLACK WHITE BLACK TYPICAL HONEYWELL R8184G,K,L or M VIOLET BROWN BLUE IntelliCon HW F F T T Break Connection Here OPERATING AQUASTAT BLACK BLACK CAD CELL EYE 120VAC ORANGE WHITE WHITE R DWG. # TYPICAL HONEYWELL R8184M, P F F G Y C W DWG# DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne CAD CELL EYE Break Connection Here RED YELLOW RED GREY YELLOW VIOLET BROWN BLUE IntelliCon HW TAPE OFF INDIVIDUALLY DIAGRAM "B" IntelliCon HW with Honeywell R8184M or P Cad Cell Relay GREY TAPE OFF INDIVIDUALLY DIAGRAM "A" IntelliCon HW with Honeywell R8184G, K, L or N Cad Cell Relay DATE Data Port Burner Motor L1 VALVE T T IGNITOR L2 LIMIT Typical Honeywell R7184 BOTTOM VIEW May Require A Piggyback Connector Red Reset Button Diagnostic Light Typical Honeywell R7184 SIDE VIEW GREY RED Break Connection Here YELLOW Typical Honeywell L4006A Aqustat Diagram "C" R DWG. # WHITE BLACK VIOLET BROWN BLUE IntelliCon DWG# Intellidyne 3/06/06 DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 CONSTANT 120 VAC TAPE OFF INDIVIDUALLY DATE IntelliCon HW LCH, LCS with Honeywell R7184A,B,P,U Electronic Oil Primary When Aquastat Is Wired 24VAC CAD CELL 3-23 3-24 3/06/06 Alarm Terminals Delay Time Dip Switch Red Reset Button Diagnostic Light Thermostat Terminals EnviroCom Terminals Data Port Typical Honeywell R7184 SIDE VIEW T T3 2 1 YELLOW GREY Typical Honeywell L4006A Aqustat Break Connection Here RED IntelliCon Diagram "D" DWG. # WHITE BLACK VIOLET BROWN BLUE R DWG# Intellidyne DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 CONSTANT 120 VAC TAPE OR WIRENUT INDIVIDUALLY DATE IntelliCon HW, LCH, LCS with Honeywell R7184A,B,P,U "SERIES 5" Electronic Oil Primary When Aquastat Is Wired 24VAC 3-25 3-26 Supply Sensor Domestic Sensor R W Field Supplied Double Pole, Double Throw Relay With 120vac Coil H HOT 115 V GND 115 V B Rewire With Jumper As Shown C C T T DWG# DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne Original Wires From "B" and "B" Terminals Going To Burner Control Circuit Remove Wires From From "B" and "B" Terminals And Rewire As Shown DWG. # NEW WIRING B HEAT TIMER (With Internal Domestic Hot Water Coil) L6006C1018 NEW WIRING OR EQUIVILANT STRAP-ON AQUASTAT USE N.O. CONTACTS Black Yellow From This Plug NOTE: Center Pins MUST BE REMOVED Splitter IntelliCon LCH N 115 VAC DATE IntelliCon LCH With Mechanical "Heat Timer" 3/06/06 3-27 3-28 3/06/06 Black Yellow NOTE: Splitter NEW WIRING Center Pins MUST BE REMOVED From This Plug IntelliCon LCH H N 1 115 VAC 2 3 4 R 5 7 DWG. # W 6 8 DWG# (With Internal Domestic Hot Water Coil) DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne L6006C1018 OR EQUIVILANT STRAP-ON AQUASTAT USE N.O. CONTACTS 9 NOTE: Not All Terminals Are Shown HEAT TIMER Model "MPC" DATE IntelliCon LCH With Heat Timer Model "MPC" Domestic Sensor Supply Temperature Sensor Steam Pressure Sensor Domestic Sensor R W Field Supplied Double Pole, Double Throw Relay With 120vac Coil H HOT 115 V GND 115 V B Rewire With Jumper As Shown C C T T DWG# DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne Original Wires From "B" and "B" Terminals Going To Burner Control Circuit Remove Wires From From "B" and "B" Terminals And Rewire As Shown DWG. # NEW WIRING B HEAT TIMER (With Internal Domestic Hot Water Coil) L6006C1018 NEW WIRING OR EQUIVILANT STRAP-ON AQUASTAT USE N.O. CONTACTS Black Yellow From This Plug NOTE: Center Pins MUST BE REMOVED Splitter IntelliCon LCS N 115 VAC DATE IntelliCon LCS With Mechanical "Heat Timer" 3/06/06 3-29 3-30 3/06/06 Black Yellow NOTE: Splitter NEW WIRING Center Pins MUST BE REMOVED From This Plug IntelliCon LCS H N 1 115 VAC 2 3 4 R 5 7 DWG. # W 6 8 DWG# (With Internal Domestic Hot Water Coil) DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne L6006C1018 OR EQUIVILANT STRAP-ON AQUASTAT USE N.O. CONTACTS 9 NOTE: Not All Terminals Are Shown HEAT TIMER Model "MPC" DATE IntelliCon LCS With Heat Timer Model "MPC" Domestic Sensor Steam Pressure Sensor 120VAC POWER H N Electronic OR Mechanical Operating Aquastat VIOLET GREY BLUE N L AUX DWG. # BURNER REILLO Addiitional Wire Added For Electronic Shutter DWG# DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne DATE (if experiencing voltage feedback from burner on IntelliCon "RED" Wire) Field Supplied 120VAC Coil Single Pole SingleThrow Relay RED YELLOW Break Connection Here BLACK BROWN WHITE R IntelliCon HW TAPE OFF INDIVIDUALLY IntelliCon HW with Riello 40F5 Burner 3/06/06 3-31 ® DATE: DWGDESC CUSTNAME TAPE OFF INDIVIDUALLY 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne DATE IntelliCon HW with Honeywell L7124A,C or L7148A Oil Electronic Aquastat DWG# IntelliCon HW DWG. # BLUE GREY VIOLET WHITE BLACK L1 120 H VAC N T L2 T TYPICAL HONEYWELL L7124A,C or L7148A C1 ZC YELLOW B2 C2 ZR B1 BROWN RED To Line Voltage Oil Burner Relay 3-32 3/06/06 Break Connection Here ® DATE: DWGDESC CUSTNAME TAPE OFF INDIVIDUALLY 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne DATE IntelliCon HW with Honeywell L7124U Universal Oil Electronic Aquastat DWG# IntelliCon HW DWG. # BLUE GREY VIOLET WHITE BLACK L1 120 H VAC N T L2 T TYPICAL HONEYWELL L7124U C1 ZC YELLOW B2 C2 ZR B1 BROWN RED To Line Voltage Oil Burner Relay Break Connection Here 3/06/06 3-33 3-34 3/06/06 VAC N To Boiler Sensor NOTE: Not All Terminals Shown L7148F HONEYWELL TYPICAL S1 R B1 R C B2 S2 L1 L1X L2X L2 120 H L2 G C L1 C2 C1 R Break Connection Here YELLOW BLUE GREY WHITE ® DWG. # RED DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne To 24vac Burner Control DWG# BROWN VIOLET BLACK IntelliCon HW TAPE OFF INDIVIDUALLY DATE IntelliCon HW with Honeywell L7148F Electronic Aquastat TO LINE VOLTAGE OIL BURNER RELAY TAPE OFF INDIVIDUALLY VIOLET GREY BLUE YELLOW Break Connection Here RED IntelliCon HW BROWN WHITE BLACK ZC B1 C1 B2 C2 L2 L1 ZR DWG. # (Not All Terminals And Wiring Shown) TYPICAL L7224U 1 2 T3 T L7224U Oil Electronic Aquastat Controller 3/06/06 DATE: CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne IntelliCon HW with Honeywell 3-35 DATE: DWGDESC CUSTNAME TAPE OFF 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne IntelliCon HW with Honeywell L8124A,C INDIVIDUALLY R DWG# IntelliCon HW DWG. # BLUE GREY VIOLET 120VAC BLACK L2 L1 T T WHITE G TYPICAL HONEYWELL L8124A,C TO LINE VOLTAGE OIL BURNER RELAY OR GAS VALVE C1 B2 BROWN RED YELLOW BREAK CONNECTION HERE 3-36 3/06/06 C2 ZR ZR B1 DATE: DWG# DWGDESC CUSTNAME ® IntelliCon HW 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 TAPE OFF INDIVIDUALLY Intellidyne DATE IntelliCon HW with HONEYWELL L8124E BLUE DWG. # BROWN VIOLET TV T Z TYPICAL HONEYWELL L8124E C1 C2 GREY BLACK B1 B2 L1 L2 G H N G WHITE YELLOW RED TO 24VAC GAS VALVE 120VAC 3/06/06 3-37 DATE: DWG# DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 ® IntelliCon HW Intellidyne TAPE OFF INDIVIDUALLY DATE IntelliCon HW with Honeywell L8124G,L BLUE DWG. # GREY VIOLET TV T Z TYPICAL HONEYWELL L8124G,L BROWN B1 B2 C2 BLACK C1 L1 L2 G H N G YELLOW RED TO LINE VOLTAGE OIL BURNER RELAY OR GAS VALVE 3-38 3/06/06 120VAC WHITE DATE: DWG# DWGDESC ® IntelliCon HW CUSTNAME TAPE OFF INDIVIDUALLY 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne DATE IntelliCon HW with Honeywell L8148A BLUE DWG. # GREY VIOLET WHITE BLACK G L1 L2 T T G 120 VAC H N TYPICAL HONEYWELL L8148A BROWN YELLOW C1 TO LINE VOLTAGE C2 B1 B2 RED OIL BURNER RELAY OR GAS VALVE 3/06/06 3-39 DATE: DWG# DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 ® IntelliCon HW Intellidyne TAPE OFF INDIVIDUALLY DATE IntelliCon HW with Honeywell L8148E BLUE DWG. # BROWN VIOLET TV W T Z TYPICAL HONEYWELL L8148E C1 C2 GREY BLACK B1 B2 L1 L2 H N YELLOW RED TO 24VAC GAS VALVE 120VAC 3-40 3/06/06 WHITE DATE: DWG# DWGDESC CUSTNAME ® IntelliCon HW 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 TAPE OFF INDIVIDUALLY Intellidyne DATE IntelliCon HW with Honeywell L8148J BLUE DWG. # BROWN VIOLET TV W TP Z T TYPICAL HONEYWELL L8148J C1 C2 GREY BLACK B1 B2 B3 L1 L2 G H N G WHITE YELLOW RED TO 24VAC GAS VALVE 120VAC 3-41 DATE: DWG# DWGDESC ® IntelliCon HW CUSTNAME TAPE OFF INDIVIDUALLY 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne DATE IntelliCon HW with Honeywell L8151A BLUE DWG. # GREY VIOLET WHITE BLACK G L1 T L2 T G 120 H VAC N TYPICAL HONEYWELL L8151A C1 ZC YELLOW B2 BROWN TO LINE VOLTAGE OIL BURNER RELAY OR GAS VALVE 3-42 3/06/06 RED C2 ZR B1 NOTE: Not All Terminals Shown TYPICAL HONEYWELL R7184 T CAD CELL VALVE IGNITOR BURNER MOTOR L2 L1 LIMIT Break Connection Here B1 T W T B2 AQUASTAT CONTROLLER T C2 C1 R THERMOSTAT CIRCULATOR PUMP YELLOW BROWN WHITE BLACK DWG. # RED ® DWG# VIOLET GREY BLUE 3/06/06 DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne TAPE OFF INDIVIDUALLY 120vac IntelliCon HW L2 L1 DATE IntelliCon HW with Honeywell R7184A,B,P,U Electronic Oil Primary 3-43 3-44 3/06/06 EnviroCom Terminals Thermostat Terminals Data Port 1 2 T3 T GREY Typical Honeywell L4006A Aqustat YELLOW DWG. # WHITE BLACK VIOLET BROWN BLUE DWG# Intellidyne DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 CONSTANT 120 VAC DATE R7184A,B,P,U "SERIES 5" Electronic Oil Primary When Aquastat Is Wired 24VAC Alarm Terminals Delay Time Dip Switch Red Reset Button Diagnostic Light Typical Honeywell R7184 SIDE VIEW Break Connection Here RED IntelliCon HW TAPE OR WIRENUT INDIVIDUALLY IntelliCon HW with Honeywell EnviroCom Terminals Thermostat Terminals Data Port 1 2 T3 T GREY Typical Honeywell L4006A Aqustat YELLOW DWG. # WHITE BLACK VIOLET BROWN BLUE DWG# Intellidyne 3/06/06 DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 CONSTANT 120 VAC DATE R7184A,B,P,U "SERIES 5" Electronic Oil Primary When Aquastat Is Wired 24VAC Alarm Terminals Delay Time Dip Switch Red Reset Button Diagnostic Light Typical Honeywell R7184 SIDE VIEW Break Connection Here RED IntelliCon HW TAPE OR WIRENUT INDIVIDUALLY IntelliCon HW with Honeywell 3-45 DATE: DWG# DWGDESC IntelliCon HW CUSTNAME Tape Off Individually ® 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne DATE IntelliCon HW with Honeywell R8182D Blue Grey White INSTRUCTIONS Remove the existing Yellow wire from the bottom of the HI Limit Setting switch. Insert the HeatManager "YELLOW" wire into the wire hole. Connect the HeatManager "RED" wire to the Yellow wire that was removed. DWG. # Violet Brown Black L1 L2 T 120 H VAC N T B B Safety Switch DIF H I Reset Button L O Circuit Board Connection ZC Yellow C1 Red F F B1 Yellow wire from bottom of HI Limit Setting 3-46 3/06/06 ZR B2 C2 DATE: DWG# DWGDESC IntelliCon HW CUSTNAME Tape Off Individually ® 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne DATE IntelliCon HW with Honeywell R8182E Blue Grey White INSTRUCTIONS Remove the Yellow wire from the bottom terminal of the Aquastat Switch. Connect the HeatManager "YELLOW" wire to this terminal. Connect the HeatManager "RED" wire to the Yellow wire that was removed DWG. # Violet Brown Black L1 L2 T 120 H VAC N T Safety Switch Reset Button Aquastat Switch Circuit Board Connection ZR ZC Yellow C1 Red F F B1 B2 C2 Yellow wire from bottom of Aquastat Switch 3/06/06 3-47 DATE: DWG# DWGDESC IntelliCon HW CUSTNAME Tape Off Individually ® 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne DATE IntelliCon HW with Honeywell R8182F Blue Grey White INSTRUCTIONS Remove the existing wire from the bottom of the HI Limit Setting switch. Insert the HeatManager "YELLOW" wire into the wire hole. Connect the HeatManager"RED" wire to the Yellow wire that was removed. DWG. # Violet Brown Black L1 L2 T 120 H VAC N T B B Safety Switch Reset Button H I L O Circuit Board Connection Yellow C1 Red F F B1 Wire from bottom of HI Limit Setting 3-48 3/06/06 B2 C2 3/06/06 3-49 120VAC ORANGE WHITE BLACK WHITE BLACK TYPICAL HONEYWELL R8184G,K,L or M VIOLET BROWN BLUE IntelliCon HW F F T T Break Connection Here OPERATING AQUASTAT BLACK BLACK CAD CELL EYE 120VAC ORANGE WHITE WHITE R DWG. # TYPICAL HONEYWELL R8184M, P F F G Y C W DWG# DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne CAD CELL EYE Break Connection Here RED YELLOW RED GREY YELLOW VIOLET BROWN BLUE IntelliCon HW TAPE OFF INDIVIDUALLY DIAGRAM "B" IntelliCon HW with Honeywell R8184M or P Cad Cell Relay GREY TAPE OFF INDIVIDUALLY DIAGRAM "A" IntelliCon HW with Honeywell R8184G, K, L or N Cad Cell Relay DATE 3-50 3/06/06 R 1 1 C 6 NO 5 2 2 Y FRS 3 1K-2 G Motor BVS W R 1K-1 Motor Damper 4 COIL 4 24V Transformer Secondary Primary 3 Circulator 120/60/1 Power Supply NC 1K-3 High Limit 4 1 THERMOSTAT Service Switch Fused Disconnect Switch L1 TH TR C L2 RED YELLOW BLUE GREY BREAK CONNECTION HERE WHITE DWG. # DWG# DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne TAPE OFF INDIVIDUALLY BROWN VIOLET BLACK IntelliCon HW DATE IntelliCon HW With Honeywell R8285D Relay/Transformer Package When Used On Boilers 120VAC POWER H N Electronic OR Mechanical Operating Aquastat VIOLET GREY BLUE N L AUX DWG. # BURNER REILLO Addiitional Wire Added For Electronic Shutter DWG# 3-06/06 DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne DATE (if experiencing voltage feedback from burner on IntelliCon "RED" Wire) Field Supplied 120VAC Coil Single Pole SingleThrow Relay RED YELLOW Break Connection Here BLACK BROWN WHITE R IntelliCon HW TAPE OFF INDIVIDUALLY IntelliCon HW with Riello 40F5 Burner 3-51 Fireye Flame Safeguard Controls General Instructions The IntelliCon® Heating Economizers are connected in series in the burner control circuit AFTER the operating safety’s and limit controls and BEFORE the burner Flame Safeguard Primary Control. ***ATTENTION MUST BE GIVEN WHEN A DRAFT INDUCER IS USED ON THE BOILER*** *** When a draft inducer is being used, the operating limit control, on closure, will activate a relay, contactor or starter to enable the draft inducer. An air proving switch will close indicating that the draft inducer is running and a negative air flow has been established through the boiler. Once the negative airflow has been established the Flame Safeguard is enabled and starts the burner sequence. Improperly connected into the operating limit circuit, the draft inducer will run drawing ambient (or cooler) air through the boiler while the IntelliCon® Heating Economizer is in the “ECONOMY” mode. Each installation should be checked for the proper connection point of the IntelliCon® Heating Economizer. The following wiring diagrams show the connection points of the IntelliCon® Heating Economizer at the Fireye Flame Safeguard ONLY. If a draft inducer is used as explained above, determine the connection point from the operating limit control BEFORE the Flame Safeguard Control. 3-52 S/W SW NOTE: Add jumper as shown between terminals "115/220" and "COMMON" SENSOR CONNECTORS 24 BURNER Alarm S2 S1 A M Burner Motor Limits 3 115 220 CALL 115/220 Ignition Main Fuel Valve 7 Interlocks P 5 L1 Note: Not all terminals shown. DWG. # LIMIT CONTROL H Intellidyne DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 N 120VAC POWER 24CJ6 Model 3010, 3011 24CU6 Model 1062, 1063 24CF6 Model 1010, 1011 L2 TYPICAL FIREYE 24CJ5, 25CU6, 26CF6 To Flame Detector Break Original Connection Here SUMMER/WINTER SWITCH SUMMER = N.C. WINTER = N.O. 24 INCOMING POWER CONNECTIONS COMMON BURNER CONTROL CIRCUIT CONNECTIONS COMMON FUTURE USE IntelliCon Wiring Compartment IntelliCon CHS or CHW With Fireye 3/06/06 3-53 S/W SW NOTE: Add jumper as shown between terminals "115/220" and "COMMON" SENSOR CONNECTORS 24 BURNER Alarm S2 S1 A M Burner Motor Limits 3 220 CALL 115/220 Ignition Main Fuel Valve 7 Interlocks P 5 L1 Note: Not all terminals shown. DWG. # LIMIT CONTROL H Intellidyne DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 N 120VAC POWER 24CJ6 Model 3010, 3011 24CU6 Model 1062, 1063 24CF6 Model 1010, 1011 L2 TYPICAL FIREYE 24CJ5, 25CU6, 26CF6 To Flame Detector Break Original Connection Here SUMMER/WINTER SWITCH SUMMER = N.C. WINTER = N.O. 115 INCOMING POWER CONNECTIONS 24 BURNER CONTROL CIRCUIT CONNECTIONS COMMON 3/06/06 COMMON 3-54 FUTURE USE IntelliCon Wiring Compartment IntelliCon CHS or CHW With Fireye S/W SW NOTE: Add jumper as shown between terminals "115/220" and "COMMON" SENSOR CONNECTORS 24 BURNER Alarm S2 S1 A M Burner Motor Limits 3 115 220 CALL 115/220 Ignition Main Fuel Valve 7 Interlocks P 5 L1 Note: Not all terminals shown. DWG. # LIMIT CONTROL H Intellidyne DATE: DWGDESC CUSTNAME 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 N 120VAC POWER 24CJ6 Model 3010, 3011 24CU6 Model 1062, 1063 24CF6 Model 1010, 1011 L2 TYPICAL FIREYE 24CJ5, 25CU6, 26CF6 To Flame Detector Break Original Connection Here SUMMER/WINTER SWITCH SUMMER = N.C. WINTER = N.O. 24 INCOMING POWER CONNECTIONS COMMON BURNER CONTROL CIRCUIT CONNECTIONS COMMON FUTURE USE IntelliCon Wiring Compartment IntelliCon CHS or CHW With Fireye 3/06/06 3-55 S/W SW 24 BURNER Alarm S2 S1 A M Burner Motor Limits 13 220 CALL 115/220 Ignition Main Fuel Valve 7 Interlocks P 5 L1 Note: Not all terminals shown. DWG. # LIMIT CONTROL H N 120VAC POWER DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne 25CU6 Model 5066 26CF6 Model 5023 24CJ5 Model 5015 L2 TYPICAL FIREYE 25CU6, 26CF6, 24CJ5 To Flame Detector Break Original Connection Here NOTE: Add jumper as shown between terminals "115/230" and "COMMON" SENSOR CONNECTORS SUMMER/WINTER SWITCH SUMMER = N.C. WINTER = N.O. 115 INCOMING POWER CONNECTIONS 24 BURNER CONTROL CIRCUIT CONNECTIONS COMMON 3/06/06 COMMON 3-56 FUTURE USE IntelliCon Wiring Compartment IntelliCon CHS or CHW With Fireye S/W SW 24 BURNER Alarm S2 S1 A M Burner Motor Limits 13 115 220 CALL 115/220 Ignition Main Fuel Valve 7 Interlocks P 5 L1 Note: Not all terminals shown. DWG. # LIMIT CONTROL H N 120VAC POWER DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne 25CU6 Model 5066 26CF6 Model 5023 24CJ5 Model 5015 L2 TYPICAL FIREYE 25CU6, 26CF6, 24CJ5 To Flame Detector Break Original Connection Here NOTE: Add jumper as shown between terminals "115/230" and "COMMON" SENSOR CONNECTORS SUMMER/WINTER SWITCH SUMMER = N.C. WINTER = N.O. 24 INCOMING POWER CONNECTIONS COMMON BURNER CONTROL CIRCUIT CONNECTIONS COMMON FUTURE USE IntelliCon Wiring Compartment IntelliCon CHS or CHW With Fireye 3/06/06 3-57 S/W SW 24 BURNER Alarm S2 S1 A M Burner Motor Limits 13 220 CALL 115/220 Ignition Main Fuel Valve 7 Interlocks P 5 L1 Note: Not all terminals shown. DWG. # LIMIT CONTROL H N 120VAC POWER DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 Intellidyne 25CU6 Model 5066 26CF6 Model 5023 24CJ5 Model 5015 L2 TYPICAL FIREYE 25CU6, 26CF6, 24CJ5 To Flame Detector Break Original Connection Here NOTE: Add jumper as shown between terminals "115/230" and "COMMON" SENSOR CONNECTORS SUMMER/WINTER SWITCH SUMMER = N.C. WINTER = N.O. 115 INCOMING POWER CONNECTIONS 24 BURNER CONTROL CIRCUIT CONNECTIONS COMMON 3/06/06 COMMON 3-58 FUTURE USE IntelliCon Wiring Compartment IntelliCon CHS or CHW With Fireye S/W SW 24 To Flame Detector Break Original Connection Here NOTE: Add jumper as shown between terminals "115/230" and "COMMON" SENSOR CONNECTORS SUMMER/WINTER SWITCH SUMMER = N.C. WINTER = N.O. BURNER S2 S1 115 220 CALL 115/220 Ignition L2 Main Fuel Valve 7 Interlocks P 5 L1 Note: Not all terminals shown. DWG. # LIMIT CONTROL H Intellidyne DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 N 120VAC POWER 25CU6 Model 3010, 3011 26CF6 Model 5022 TYPICAL FIREYE 25CU6, 26CF6 Alarm A M Burner Motor Limits 13 24 INCOMING POWER CONNECTIONS COMMON BURNER CONTROL CIRCUIT CONNECTIONS COMMON FUTURE USE IntelliCon Wiring Compartment IntelliCon CHS or CHW With Fireye 3/06/06 3-59 S/W SW 24 To Flame Detector Break Original Connection Here NOTE: Add jumper as shown between terminals "115/230" and "COMMON" SENSOR CONNECTORS SUMMER/WINTER SWITCH SUMMER = N.C. WINTER = N.O. BURNER S2 S1 220 CALL 115/220 Ignition L2 Main Fuel Valve 7 Interlocks P 5 L1 Note: Not all terminals shown. DWG. # LIMIT CONTROL H Intellidyne DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 N 120VAC POWER 25CU6 Model 3010, 3011 26CF6 Model 5022 TYPICAL FIREYE 25CU6, 26CF6 Alarm A M Burner Motor Limits 13 115 INCOMING POWER CONNECTIONS 24 BURNER CONTROL CIRCUIT CONNECTIONS COMMON 3/06/06 COMMON 3-60 FUTURE USE IntelliCon Wiring Compartment IntelliCon CHS or CHW With Fireye S/W SW 24 To Flame Scanner Break Original Connection Here NOTE: Add jumper as shown between terminals "115/230" and "COMMON" SENSOR CONNECTORS SUMMER/WINTER SWITCH SUMMER = N.C. WINTER = N.O. BURNER S2 S1 115 220 CALL 115/220 Main Fuel Pilot Valve Ignition L2 7 3 4 L1 Note: Not all terminals shown. DWG. # LIMIT CONTROL H Intellidyne DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 N 120VAC POWER EP (D) 160 EP 161 EP (D) 170 Flame Monitors TYPICAL FIREYE E- Series Alarm A M Burner Motor Limits 13 24 INCOMING POWER CONNECTIONS COMMON BURNER CONTROL CIRCUIT CONNECTIONS COMMON FUTURE USE IntelliCon Wiring Compartment IntelliCon CHS or CHW With Fireye 3/06/06 3-61 S/W SW 24 To Flame Scanner Break Original Connection Here NOTE: Add jumper as shown between terminals "115/230" and "COMMON" SENSOR CONNECTORS SUMMER/WINTER SWITCH SUMMER = N.C. WINTER = N.O. BURNER S2 S1 220 CALL 115/220 3 6 4 2 Main Fuel Pilot Valve Ignition 1 Note: Not all terminals shown. DWG. # LIMIT CONTROL H Intellidyne DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 N 120VAC POWER Modular M Series TYPICAL FIREYE Micro-M Alarm A 8 Burner Motor Limits 7 115 INCOMING POWER CONNECTIONS 24 BURNER CONTROL CIRCUIT CONNECTIONS COMMON 3/06/06 COMMON 3-62 FUTURE USE IntelliCon Wiring Compartment IntelliCon CHS or CHW With Fireye S/W SW 24 T-Stat or Operating Control Break Original Connection Here NOTE: Add jumper as shown between terminals "115/230" and "COMMON" SENSOR CONNECTORS SUMMER/WINTER SWITCH SUMMER = N.C. WINTER = N.O. BURNER T T 115 220 CALL S S Ignition 4 Main Fuel 5 3/06/06 Note: Not all terminals shown. 2 TYPICAL FIREYE UVM-1 Alarm A 3 Burner Motor Limits 1 24 115/220 INCOMING POWER CONNECTIONS COMMON BURNER CONTROL CIRCUIT CONNECTIONS COMMON FUTURE USE IntelliCon Wiring Compartment DWG. # LIMIT CONTROL H N Intellidyne DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 120VAC POWER IntelliCon CHS or CHW With Fireye UVM - 1 3-63 S/W SW 24 To Flame Detector Break Original Connection Here NOTE: Add jumper as shown between terminals "115/230" and "COMMON" SENSOR CONNECTORS SUMMER/WINTER SWITCH SUMMER = N.C. WINTER = N.O. BURNER S2 S1 220 CALL 115/220 Ignition 2 No 1 Oil Valve 3 Air Flow Switch 6 4 1 Note: Not all terminals shown. DWG. # (Not Used On TFM Models) LIMIT CONTROL H Intellidyne DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 N 120VAC POWER UVM-1D, 1F, 2A, 3 TFM-1D,1F, 2A, 3 TYPICAL FIREYE UVM, TFM Alarm A 8 7 Burner Motor Limits 115 INCOMING POWER CONNECTIONS 24 BURNER CONTROL CIRCUIT CONNECTIONS COMMON 3/06/06 COMMON 3-64 FUTURE USE IntelliCon Wiring Compartment IntelliCon CHS or CHW With FIREYE S/W SW 24 To Flame Detector Break Original Connection Here Add jumper as shown between terminals "115/230" and "COMMON" SENSOR CONNECTORS SUMMER/WINTER SWITCH SUMMER = N.C. WINTER = N.O. BURNER S2 S1 115 220 CALL 115/220 Ignition 2 No 1 Oil Valve/Pilot Gas Valve 3 Air Flow Switch 6 4 1 Note: Not all terminals shown. DWG. # LIMIT CONTROL H N Intellidyne DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 120VAC POWER UVM-2A and TFM-2A TYPICAL FIREYE UVM, TFM Alarm A 8 Burner Motor Limits 7 24 INCOMING POWER CONNECTIONS COMMON BURNER CONTROL CIRCUIT CONNECTIONS COMMON FUTURE USE IntelliCon Wiring Compartment IntelliCon CHS or CHW With FIREYE 3/06/06 3-65 S/W SW 24 To Flame Detector Break Original Connection Here NOTE: Add jumper as shown between terminals "115/230" and "COMMON" SENSOR CONNECTORS SUMMER/WINTER SWITCH SUMMER = N.C. WINTER = N.O. BURNER S2 S1 220 CALL 115/220 Ignition 2 No 1 Oil Valve/Pilot Gas Valve 3 Air Flow Switch 6 4 1 Note: Not all terminals shown. DWG. # (Not Used On TFM Models) LIMIT CONTROL H N Intellidyne DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 120VAC POWER UVM-3 and TFM-3 TYPICAL FIREYE UVM, TFM Alarm A 8 7 Burner Motor Limits 115 INCOMING POWER CONNECTIONS 24 BURNER CONTROL CIRCUIT CONNECTIONS COMMON 3/06/06 COMMON 3-66 FUTURE USE IntelliCon Wiring Compartment IntelliCon CHS or CHW With FIREYE TAPE OFF INDIVIDUALLY VIOLET GREY BLUE BLACK WHITE BROWN S2 S1 Alarm A M 3 Burner Motor Limits RED YELLOW Ignition L2 Main Fuel Valve 7 Interlocks P 5 L1 3/06/06 Note: Not all terminals shown. DWG. # LIMIT CONTROL TYPICAL FIREYE 24CJ5, 25CU6, 26CF6 To Flame Detector Break Original Connection Here IntelliCon H Intellidyne DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 N 120VAC POWER IntelliCon LCH or LCS With FIREYE 24CJ5 Model 3010, 3011 25CU6 Model 1062,1063 26CF6 Model 1010, 1011 3-67 3-68 3/06/06 TAPE OFF INDIVIDUALLY VIOLET GREY BLUE BLACK WHITE BROWN S2 S1 Alarm A M 3 Burner Motor Limits RED YELLOW Ignition L2 Main Fuel Valve 7 Interlocks P 5 L1 Note: Not all terminals shown. DWG. # LIMIT CONTROL TYPICAL FIREYE 24CJ5, 25CU6, 26CF6 To Flame Detector Break Original Connection Here IntelliCon H Intellidyne DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 N 120VAC POWER IntelliCon LCH or LCS With FIREYE 24CJ5 Model 3010, 3011 25CU6 Model 1062,1063 26CF6 Model 1010, 1011 TAPE OFF INDIVIDUALLY VIOLET GREY BLUE BLACK WHITE BROWN S2 S1 Alarm A M 3 Burner Motor Limits RED YELLOW Ignition L2 Main Fuel Valve 7 Interlocks P 5 L1 3/06/06 Note: Not all terminals shown. DWG. # LIMIT CONTROL TYPICAL FIREYE 24CJ5, 25CU6, 26CF6 To Flame Detector Break Original Connection Here IntelliCon H Intellidyne DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 N 120VAC POWER IntelliCon LCH or LCS With FIREYE 24CJ5 Model 3010, 3011 25CU6 Model 1062,1063 26CF6 Model 1010, 1011 3-69 3-70 3/06/06 TAPE OFF INDIVIDUALLY VIOLET GREY BLUE BLACK WHITE BROWN A S2 S1 Alarm Burner Motor M 13 Limits RED YELLOW Ignition L2 Main Fuel Valve 7 Interlocks P 5 L1 Note: Not all terminals shown. DWG. # LIMIT CONTROL TYPICAL FIREYE 25CU6, 26CF6, 24CJ5 To Flame Detector Break Original Connection Here IntelliCon H Intellidyne DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 N 120VAC POWER IntelliCon LCH or LCS With FIREYE 25CU6 Model 5066 26CF6 Model 5023 24CJ5 Model 5015 TAPE OFF INDIVIDUALLY VIOLET GREY BLUE BLACK WHITE BROWN A S2 S1 Alarm Burner Motor M 13 Limits RED YELLOW Ignition L2 Main Fuel Valve 7 Interlocks P 5 L1 Note: Not all terminals shown. DWG. # LIMIT CONTROL TYPICAL FIREYE 25CU6, 26CF6, 24CJ5 To Flame Detector Break Original Connection Here IntelliCon H Intellidyne DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 N 120VAC POWER IntelliCon LCH or LCS With FIREYE 25CU6 Model 5066 26CF6 Model 5023 24CJ5 Model 5015 3/06/06 3-71 3-72 3/06/06 TAPE OFF INDIVIDUALLY VIOLET GREY BLUE BLACK WHITE BROWN A S2 S1 Alarm Burner Motor M 13 Limits RED YELLOW Ignition L2 Main Fuel Valve 7 Interlocks P 5 L1 Note: Not all terminals shown. DWG. # LIMIT CONTROL TYPICAL FIREYE 25CU6, 26CF6, 24CJ5 To Flame Detector Break Original Connection Here IntelliCon H Intellidyne DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 N 120VAC POWER IntelliCon LCH or LCS With FIREYE 25CU6 Model 5066 26CF6 Model 5023 24CJ5 Model 5015 TAPE OFF INDIVIDUALLY VIOLET GREY BLUE BLACK WHITE BROWN To Flame Detector Break Original Connection Here IntelliCon A Ignition L2 Main Fuel Valve 7 Interlocks P 5 L1 3/06/06 Note: Not all terminals shown. TYPICAL FIREYE 25CU6, 26CF6 S2 S1 Alarm Burner Motor M 13 Limits RED YELLOW DWG. # LIMIT CONTROL H Intellidyne DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 N 120VAC POWER IntelliCon LCH or LCS With FIREYE 25CU6 Model 5065 26CF6 Model 5022 3-73 3-74 3/06/06 TAPE OFF INDIVIDUALLY VIOLET GREY BLUE BLACK WHITE BROWN To Flame Detector Break Original Connection Here IntelliCon A Ignition L2 Main Fuel Valve 7 Interlocks P 5 L1 Note: Not all terminals shown. TYPICAL FIREYE 25CU6, 26CF6 S2 S1 Alarm Burner Motor M 13 Limits RED YELLOW DWG. # LIMIT CONTROL H Intellidyne DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 N 120VAC POWER IntelliCon LCH or LCS With FIREYE 25CU6 Model 5065 26CF6 Model 5022 TAPE OFF INDIVIDUALLY VIOLET GREY BLUE BLACK WHITE BROWN To Flame Scanner Break Original Connection Here IntelliCon 7 3 4 L2 Main Fuel Pilot Valve Ignition L1 3/06/06 Note: Not all terminals shown. TYPICAL FIREYE E-Series S2 S1 Lockout Alarm A M 13 Burner Motor Limits RED YELLOW DWG. # LIMIT CONTROL H Intellidyne DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 N 120VAC POWER IntelliCon LCH or LCS With FIREYE EP(D)160 EP161 EP(D)170 Flame Monitors 3-75 3-76 3/06/06 To Flame Scanner 5 3 4 2 Main Fuel Pilot Valve Ignition 1 Note: Not all terminals shown. TYPICAL FIREYE Micro-M S2 S1 Alarm A 8 7 Burner Motor Limits RED YELLOW DWG. # LIMIT CONTROL Intellidyne DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 N Modular M Series TAPE OFF INDIVIDUALLY VIOLET GREY BLUE BLACK WHITE BROWN Break Original Connection Here IntelliCon H 120VAC POWER IntelliCon LCH or LCS With FIREYE TAPE OFF INDIVIDUALLY VIOLET GREY BLUE BLACK WHITE BROWN T-Stat or Operating Control Break Original Connection Here IntelliCon S S 4 2 Ignition Main Fuel 5 3/06/06 Note: Not all terminals shown. TYPICAL FIREYE UVM-1 T T Alarm A 3 1 Burner Motor Limits RED YELLOW DWG. # LIMIT CONTROL H Intellidyne DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 N 120VAC POWER IntelliCon LCH or LCS With FIREYE UVM-1 3-77 3-78 3/06/06 TAPE OFF INDIVIDUALLY VIOLET GREY BLUE BLACK WHITE BROWN To Flame Detector Break Original Connection Here IntelliCon Ignition 2 No 1 Oil Valve 3 Air Flow Switch 6 4 1 Note: Not all terminals shown. TYPICAL FIREYE UVM, TFM S2 S1 Alarm A 8 7 Burner Motor Limits RED YELLOW DWG. # (Not Used On TFM Models) LIMIT CONTROL H Intellidyne DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 N 120VAC POWER IntelliCon LCH or LCS With FIREYE UVM-1D, 1F, 2A, 3 TFM-1D, 1F, 2A, 3 TAPE OFF INDIVIDUALLY VIOLET GREY BLUE BLACK WHITE BROWN To Flame Detector Break Original Connection Here IntelliCon Ignition 2 No 1 Oil Valve/Pilot Gas Valve 3 Air Flow Switch 6 4 1 3/06/06 Note: Not all terminals shown. TYPICAL FIREYE UVM, TFM S2 S1 Alarm A 8 7 Burner Motor Limits RED YELLOW DWG. # LIMIT CONTROL H Intellidyne DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 N 120VAC POWER IntelliCon LCH With FIREYE UVM-2A and TFM-2A 3-79 3-80 3/06/06 TAPE OFF INDIVIDUALLY VIOLET GREY BLUE BLACK WHITE BROWN To Flame Detector Break Original Connection Here IntelliCon Ignition 2 No 1 Oil Valve/Pilot Gas Valve 3 Air Flow Switch 6 4 1 Note: Not all terminals shown. TYPICAL FIREYE UVM, TFM S2 S1 Alarm A 8 7 Burner Motor Limits RED YELLOW DWG. # (Not Used On TFM Models) LIMIT CONTROL H Intellidyne DATE: CUSTNAME DWGDESC 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 N 120VAC POWER IntelliCon LCH or LCS With FIREYE UVM-3 and TFM-3 Honeywell Flame Safeguard Controls General Instructions ® The IntelliCon Heating Economizers are connected in series in the burner control circuit AFTER the operating safety’s and limit controls and BEFORE the burner Flame Safeguard Primary Control. ***ATTENTION MUST BE GIVEN WHEN A DRAFT INDUCER IS USED ON THE BOILER*** *** When a draft inducer is being used, the operating limit control, on closure, will activate a relay, contactor or starter to enable the draft inducer. An air proving switch will close indicating that the draft inducer is running and a negative air flow has been established through the boiler. Once the negative airflow has been established the Flame Safeguard is enabled and starts the burner sequence. Improperly connected into the operating limit circuit, the draft inducer will run drawing ambient (or cooler) air through the boiler while the IntelliCon® Heating Economizer is in the “ECONOMY” mode. Each installation should be checked for the proper connection point of the IntelliCon® Heating Economizer. The following wiring diagrams show the connection points of the IntelliCon® Heating Economizer at the Honeywell Flame Safeguard ONLY. If a draft inducer is used as explained above, determine the connection point from the operating limit control BEFORE the Flame Safeguard Control. 3/06/06 3-81 S/W SW WINTER = N.O. SUMMER = N.C. N H 120VAC POWER NOTE: Add jumper as shown between terminals "115/220" and "COMMON" SENSOR CONNECTORS SUMMER/WINTER SWITCH L1 Lockout Interlockouts 3 Note: Not all terminals shown. Limit Circuit 4 Pilot/ Ignition 6 Main Fuel Valve/s 7 Burner Motor 8 TYPICAL R4140 or 4150 9 G F 120vac Neutral Alarm 220 L2 120vac Hot INCOMING POWER CONNECTIONS 115 BURNER CALL 115/220 24 BURNER CONTROL CIRCUIT CONNECTIONS 24 USE COMMON 3/06/06 COMMON 3-82 FUTURE IntelliCon Wiring Compartment DWG. # Break Original Connection Here Limits And Burner Controller DATE: 90 Pratt Oval Glen Cove, NY 11542 (516) 676-0777 CUSTNAME Intellidyne IntelliCon CHS or CHW With Honeywell R4140G, L,M or R4150A, C, X IntelliCon CHS or CHW With Honeywell R4795A,D IntelliCon Wiring Compartment FUTURE BURNER CONTROL CIRCUIT CONNECTIONS USE INCOMING POWER CONNECTIONS SUMMER/WINTER SWITCH COMMON COMMON 24 115 BURNER 115/220 220 CALL SUMMER = N.C. WINTER = N.O. 24 SENSOR CONNECTORS S/W SW NOTE: Add jumper as shown between terminals "115/220" and "COMMON" Limits And Burner Controller 1 5 2nd Stage Oil Valve Break Original Connection Here 8 4 Ignition Burner Motor 3 7 Air Switch To Flame Detector 1st Stage Oil Valve F 6 Air Switch 2 G 120VAC POWER TYPICAL R4795A,D H Note: Not all terminals shown. N 3/06/06 3-83 S/W SW 24 To Flame Detector NOTE: Add jumper as shown between terminals "115/230" and "COMMON" SENSOR CONNECTORS SUMMER/WINTER SWITCH SUMMER = N.C. WINTER = N.O. BURNER 8 Pilot Valve Air Switch L2 Main Fuel Valve 6 3 Ignition 18 5 Note: Not all terminals shown. TYPICAL R7795 Break Original Connection Here 220 CALL 115/220 DWG. # LIMIT CONTROL H 90 Pratt Oval Intellidyne DATE: CUSTNAME DWGDESC Glen Cove, NY 11542 (516) 676-0777 N 120VAC POWER R7795A, B, C, D G F 16 Burner Motor Alarm 9 115 INCOMING POWER CONNECTIONS 24 BURNER CONTROL CIRCUIT CONNECTIONS COMMON 3/06/06 COMMON 3-84 FUTURE USE IntelliCon Wiring Compartment IntelliCon CHS or CHW With Honeywell S/W SW NOTE: Add jumper as shown between terminals "115/230" and "COMMON" SENSOR CONNECTORS To Flame Detector SUMMER/WINTER SWITCH SUMMER = N.C. WINTER = N.O. BURNER 220 Break Original Connection Here 115 CALL 115/220 24 L2 Main Fuel Valve 9 Interlocks 7 Ignition 10 4 3/06/06 Note: Not all terminals shown. TYPICAL RM7800/RM7840 E, G, L, M G 6 F 5 Burner Motor Alarm 3 24 INCOMING POWER CONNECTIONS COMMON BURNER CONTROL CIRCUIT CONNECTIONS COMMON FUTURE USE IntelliCon Wiring Compartment LIMIT CONTROL H N 120VAC POWER IntelliCon CHS or CHW With Honeywell RM7800/RM7840 E, G, L, M 3-85 SWITCH 3 SYSTEM CONTROLLER OR TANK TEMP. CONTROLLER 1 2 1 BLACK 2 3 4 5 6 7 8 BLACK YELLOW WHITE TERMINAL STRIP 120vac Hot RED BLACK RED 120vac Neutral NC NO C RED BLUE COMBINATION HIGH LIMIT MANUAL HIGH LIMIT WHITE BLACK GREEN RED C R TRANSFORMER MV/PV Break Original Connection Here WHITE IGNITION MODULE BLACK WHITE GREY RED YELLOW VIOLET BROWN BLUE IntelliCon LCH INDIVIDUALLY TAPE OFF NOTE: NOT ALL CONTROLS AND WIRING SHOWN AUTO RESET HIGH LIMIT FLOW SWITCH YELLOW WHITE PV MV RED GND BLACK 24V (G) 3/06/06 SPARK 3-86 24V THERMAL BALANCER IntelliCon LCH with AO Smith DuraMax Models DB/DW 720 - 1810 TAPE OFF INDIVIDUALLY VIOLET GREY BLUE IntelliCon 2 1 3 Note: Not all terminals shown. TYPICAL R890 G F T Here 4 T Connection Break 5 6 RED YELLOW LIMIT CONTROL BROWN WHITE BLACK H N 120VAC POWER IntelliCon LCH Or LCS With Honeywell R890E, F, G 3/06/06 3-87 3-88 3/06/06 TAPE OFF INDIVIDUALLY VIOLET GREY BLUE 120VAC POWER N H WHITE BROWN BLACK IntelliCon L1 9 Burner Motor Limit Circuit Lockout Interlockouts 3 4 Pilot/ Ignition 6 Main Fuel Valve/s 7 8 Note: Not all terminals shown. TYPICAL R4140 or 4150 Alarm G F 120vac Neutral L2 120vac Hot RED Break Original Connection Here YELLOW Limits And Burner Controller IntelliCon LCH or LCS With Honeywell R4140G, L,M or R4150A, C, X TAPE OFF INDIVIDUALLY VIOLET GREY BLUE IntelliCon To Flame Detector F Break Connection Here Ignition 2 6 Air Switch 1st Stage Oil Valve 3 4 2nd Stage Oil Valve 5 3/06/06 Note: Not all terminals shown. TYPICAL R4795 G Air Switch 7 Burner Motor 8 1 RED YELLOW LIMIT CONTROL BROWN WHITE BLACK H N 120VAC POWER IntelliCon LCH OR LCS With Honeywell R4795A,D 3-89 3-90 TAPE OFF INDIVIDUALLY VIOLET GREY BLUE RED BLACK WHITE BROWN To Flame Detector YELLOW IntelliCon Break Original Connection Here L2 Main Fuel Valve 9 Interlocks 7 Ignition 10 4 3/06/06 Note: Not all terminals shown. TYPICAL RM7800/RM7840 E, G, L, M G 6 F 5 Burner Motor Alarm 3 LIMIT CONTROL H N 120VAC POWER IntelliCon LCH OR LCS With Honeywell RM7800/RM7840 E, G, L, M 3-91 3-92 3/06/06 TAPE OFF INDIVIDUALLY VIOLET GREY BLUE RED BLACK WHITE BROWN To Flame Detector YELLOW IntelliCon 4 Break Original Connection Here L2 Main Fuel Valve 9 Interlocks 7 Ignition 10 5 Note: Not all terminals shown. TYPICAL RM7895 G 22 F 6 Burner Motor Alarm 3 LIMIT CONTROL/S H N 120VAC POWER IntelliCon LCH OR LCS With Honeywell RM7895 REFRIGERATION CAUTION: Read and follow these general instructions and the instructions that are packed with the IntelliCon® Model RU. Failure to follow these instructions could result in damage to the system or cause a hazardous condition. General Instructions PUMP DOWN SYSTEMS: When installing the Model RU on pump down type refrigeration systems the IntelliCon® RU should be connected so that the call for the liquid line solenoid valve is delayed from opening instead of delaying the compressor. This assures that the evaporator is not flooded with refrigerant. OIL PRESSURE SAFETY CONTROLS: CAUTION: Do not connect the IntelliCon® RU after the oil pressure safety control! Some commercial refrigeration systems utilize compressor oil pressure safety controls. The compressor oil pressure safety control has a time delay to allow the compressor to build up proper oil pressure. This time delay is energized on a call for the compressor to run. If the IntelliCon® RU is wired incorrectly in the control circuit, the oil pressure safety control could time-out resulting in a manual reset lockout condition. The wiring diagrams that follow show the correct installation of the IntelliCon® RU in such a system. NOTE: The following diagrams are representative of typical refrigeration systems and do not show all controls that may be in your particular system. Actual system wiring may differ 5/31/2006 1 4-1 4-2 4-3 4-4 4-5 4-6 5-1 5-2 5-3 5-4 5-5 5-6 NOTES 3/06/06 NOTES 3/06/06 NOTES 3/06/06 NOTES 3/06/06 IntelliCon® Application Guidelines Applications: • • • • • • • • • • • • • • • Packaged Air Conditioning Units Split Type Air Conditioning Units Self Contained, Air or Water Cooled Air Conditioning Units Heat Pumps, (water source or air to air) Residential Hot Water Heating Systems (Demand Type) Residential Heat Pumps Residential Central Air Conditioning Residential Forced Warm Air Furnaces (gas or oil fired) Commercial Forced Warm Air Units (Stand-Alone or Packaged Rooftop HVAC, gas or oil fired) Commercial Refrigeration (>1.0 HP) Commercial Steam Heating Boilers (with or without a Domestic Hot Water Coil) Commercial Hot Water Heating Boilers (with or without a Domestic Hot Water Coil) Commercial Hot Water Heaters (gas or oil only) Indirectly Heated Absorption Chillers Screw Type Compressors (Used in Demand Applications) Non-Applications: • • • • • • • • • • • • • • • • Centrifugal Compressors Screw Compressors (Proportionally Controlled) Commercial Refrigeration (< 1HP) Refrigeration Cascade Systems Refrigeration Rack Systems (Pending release of PDL product) Ice Machines Direct Fired Absorption Chillers (Pending release of DFC product) Window or Wall Type Air Conditioners (Pending release of ACW product) Ductless Mini Split Air Conditioning (Pending release of ACW product) Heated “Make–up Air” Units Chillers or Boilers used for Process Control Electric Hot Water Heaters Milli-Volt or Self Generating PowerPile Systems York “Millinium” Chillers Proportionally Controlled Chillers Carrier “FloTronic” Chillers 5/31/2006 1 3/06/06
Similar documents
Howling Cow Nutrition Information
Mononitrate (Vitamin B1), Riboflavin n (Vitamin B2), Folic A Acid), Sugar, Palm Oil, W Whey (From Milk), Corn Syrup, Salt, Cornstarch, Eggs, Baking Soda, Dextrose, Natuural and Artiificial Flavor...
More information