gaS meterS - E-Gaz
Transcription
gaS meterS - E-Gaz
G a s meters from metering to data management GAS meters P roduct ran g e GAS METERS from METERING to data management Vision Apator Group is one of the most important supplier in EMEA region in the development and sales metering equipment and systems as well as switchgear equipment. Mission Be promoter and leading supplier of modern metering systems for utility services and maintain the possition of important supplier on the market of low voltage switchgear equipment. Strategic objective The establishment of strong technological group acting in metering and switchgear segments based on strong brand of Apator and oriented at the increase of sales on foreign markets. from metering to data management Apator Metrix content exists from: Established in 1948 (Pomeranian gas meter factory) since 2004 is part of the Apator Group Scope of business: Diaphragm domestic, commercial and industrial gas meter including smart solutions. Certificates: ISO 9001:2000, ISO 14001:2004 Conformity to: EN1359; 2004/22/EC (MID) OIML R31/RC 71/318/EC Residential and commercial gas meters 04 UG series___________________________________ 06 6G4L, 6G6___________________________________ 07 AM-G10, AM-G16_____________________________ 08 Industrial gas meters 10 2G25L______________________________________ 12 2G40L, 2G65L________________________________ 13 Smart gas meters 14 gas meters Residential and commercial gas meters with mechanical index from metering to data management 110 / 130 mm 100 / 110 / 130 mm 152,4 / 160 mm 220 mm 000 130 mm 220 mm 250 mm 280 / 300 mm Type Maximum flow rate m3/h Minimum flow rate m3/h UG-G1,6 UG-G2,5 UG-G4 6G4L 6G6 AM-G10 AM-G16 2,5 4 6 6 10 16 25 0,04 0,06 0,1 0,16 0,016 0,016/0,025 0,016/0,025 /0,040 Nominal flow rate 3 m /h 1,6 2,5 4 4 6 10 16 Cyclic volume dm3 1,2 1,2 1,2 2,2 2,2 5 5 Max working pressure bar 0,5 0,5 0,5 0,5 0,5 0,5 0,5 Index max indication m3/h 99999,999 99999,999 99999,999 99999,999 99999,999 999999,99 999999,99 Starting flow rate dm3/h 3 5 5 5 8 13 13 bar 0,1 0,1 0,1 0,1 0,1 Fireproof up to 650 ºC according to EN 1359 Thread Threaded connections may be manufactured acc. to any international norm (ISO; ANSI; British Standard etc.....) 5 gas meters UG series Ug series gas meters are designed for measurement of gas supplied to appartments where sonsumption of gas is equivalent of 2,5 m3/h (G1,6), 4 m3/h (G2,5) and 6 m3/h (G4) of air density of 1,2 kg/m3. UG series The gas meters can be used for measurement of: Natural gas City gas Propane-butane gas Gas meter is equipped with pulse magnet as standard. Pulse transmitter can be added at any time (1 imp = 0,01 m3). Table 1. Technical Data UG-G1,6 UG-G2,5 Maximum flow rate m3/h 2,5 4 UG-G4 6 Minimum flow rate m3/h 0,016 0,016/0,025 0,016/0,025/0,040 Nominal flow rate m3/h 1,6 2,5 4 Cyclic volume dm3 1,2 1,2 1,2 Max working pressure bar 0,5 0,5 0,5 Index max indication m3/h 99999,999 99999,999 99999,999 Starting flow rate dm3/h 3 5 5 bar 0,1 0,1 0,1 Fireproof up to 650 ºC according to EN 1359 Dimensions A [mm] B [mm] Variant I Variant II C [mm] Variant I Variant II D [mm] Variant I Variant II E [mm] Variant I Weight Variant II 100 – 200 – 205 to 211 – 161 – 70 1,7 kg 110 216 200 214 205 to 211 167 161 67 70 ~ 2,0 kg 130 216 200 214 205 to 211 167 161 67 70 ~ 2,0 kg 152,4 235 – 268 – 177 – 73 – ~ 3,0 kg 160 235 – 240 – 177 – 73 – ~ 3,0 kg 220 283 – 222 – 176 – 72 – ~ 2,0 kg Curves of Typical error and Pressure loss UG-G1,6 UG-G2,5 UG-G4 3 3 2 2 2 1 1 1 0 0 EN1359 /OIML R31 -1 -2 -3 3 -2 71/318/EWG 0 0,5 1 1,5 2,5 2 2.0 1.5 1 1.0 -3 -2 71/318/EWG 1 0 2 0 0,5 1 1,5 2 2,5 4 3 -3 71/318/EWG 0 2.0 2.0 1.5 1.5 1 2 3 4 5 6 1 1.0 1 2 2 1 2 EN1359 /OIML R31 -1 1.0 2 0.5 0 0 EN1359 /OIML R31 -1 0.5 0 0.5 0 1 2 3 4 0 0 1 2 3 4 5 6 from metering to data management 7 6G4L, 6G6 The gas meter 6G4L and 6G6 is designed for measurement of gas supplied to appartments where maximum consumption of gas is equivalent of 6m3 (G4) and 10m3 (G6) of air density of 1,2 kg/m3. The gas meters can be used for measurement of: 6G4L, 6G6 Natural gas City gas Propane-butane gas Gas meter is equipped with pulse magnet as standard. Pulse transmitter can be added at any time (1 imp = 0,01 m3). Table 3. Technical Data 6G4L 6G6 Maximum flow rate m3/h 6 10 Minimum flow rate m3/h 0,04 0,06 Nominal flow rate m3/h 4 6 Cyclic volume dm3 2,2 2,2 Max working pressure bar 0,5 0,5 Index max indication m3/h 99999,999 99999,999 Starting flow rate dm3/h 5 8 bar 0,1 0,1 Fireproof up to 650 ºC according to EN 1359 Dimensions A [mm] B [mm] C [mm] 78 3,0 kg 130 231 276 187 78 3,4 kg 220 326 286 190 79 3,4 kg 250 326 276 190 79 3,4 kg 3 2 1 1 0 0 -2 -3 -2 71/318/EWG 0 1 2 3 4 6 5 -3 71/318/EWG 0 2 4 6 8 10 2.0 2.0 1.5 1 1.5 1 1.0 2 1.0 2 0.5 0.5 0 EN1359 /OIML R31 -1 EN1359 /OIML R31 0 0 1 2 3 4 5 6 Weight 187 2 -1 E [mm] 289 6G6 3 231 Curves of Typical error and Pressure loss 6G4L D [mm] Single pipe 0 1 2 3 4 5 6 gas meters AM-G10/AM-G16 AM-G10/AM-G16 The gas meters AM-G10 and AM-G16 are designed for measurement of gas supplied to commercial and industrial gas meters where maximum consumption of gas is equivalent of 16 m3 (G10) and 25m3 (G16) of air density of 1,2 kg/m3. The gas meters can be used for measurement of: Natural gas City gas Propane-butane gas Gas meter is equipped with pulse magnet as standard. Pulse transmitter can be added at any time (1 imp = 0,1 m3). Table 4. Technical Data AMG 10 AMG 16 Maximum flow rate m3/h 16 25 Minimum flow rate m3/h 0,1 0,16 Nominal flow rate m3/h 10 16 Cyclic volume dm3 5 5 Max working pressure bar 0,5 0,5 Index max indication m3/h 999999,99 999999,99 Starting flow rate dm3/h 13 13 bar 0,1 0,1 Fireproof up to 650 ºC according to EN 1359 Dimensions A [mm] B [mm] C [mm] 6,8 kg 300 395 345 214 93 6,8 kg 2 2 1 0 -2 -3 0 4 8 EN1359 /OIML R31 -1 -2 71/318/EWG 16 12 3.0 -3 71/318/EWG 0 5 10 15 25 20 3.0 1 2.5 2.0 2 2.0 1 2 1.0 1.5 1.0 0.5 0 0 4 8 12 16 Weight 93 1 EN1359 /OIML R31 E [mm] 214 3 0 345 AMG 10AMG 16 -1 D [mm] 395 Curves of Typical error and Pressure loss 3 280 0 0 5 10 15 20 25 from metering to data management Innovative index Innovative index with innovative protection against fraud Place for applying an ordinary seal (optional) New generation solution for seal (stamp from inside) Index blockade Applying (or not applying) decides, if the index is disassemblable or non-disassemblable 9 gas meters Industrial gas meters with the mechanical index from metering to data management Type 2G25L 2G40L 2G65L Maximum flow rate m3/h 40 65 100 Minimum flow rate 3 m /h 0,25 0,40 0,65 Nominal flow rate m3/h 25 40 65 Cyclic volume 3 dm 20 65 65 Max working pressure bar 0,2 0,2 0,2 Index max indication m3/h 999999,99 999999,99 999999,99 Starting flow rate dm /h 20 32 32 3 11 gas meters 2G25L The gas meter G25 is designed for measurement of gas supplied to industrial plants where maximum consumption of gas is equivalent of 40m3/h of air of density of 1,2 kg/m3. Natural gas City gas Propane-butane gas Gas meter is equipped with pulse magnet as standard. Pulse transmitter can be added at any time (1 imp = 0,1 m3). Table 6. Technical Data 2G25L Maximum flow rate m3/h 40 Minimum flow rate m3/h 0,25 Nominal flow rate m3/h 25 Cyclic volume dm3 20 Max working pressure bar 0,2 Index max indication m3/h 999999,99 Starting flow rate dm3/h 20 bar 0,1 Fireproof up to 650 ºC according to EN 1359 Dimensions A E D A [mm] 335 C 2G25L The gas meters can be used for measurement of: B [mm] 538 B Curves of Typical error and Pressure loss 2G25L 3 2 1 0 EN1359 /OIML R31 -1 -2 -3 71/318/EWG 0 10 20 30 3.0 40 1 2 2.0 1.0 0 0 10 20 30 40 C [mm] 520 D [mm] 308 E [mm] 151 Weight 30 kg from metering to data management 13 2G40L, 2G65L The gas meters 2G40L and 2G65L are designed for measurement of gas supplied to industrial plants where maximum consumption of gas is equivalent of 65 m3 (G40) and 100 m3 (G65) of air density of 1,2 kg/m3. 2G40L, 2G65L The gas meters can be used for measurement of: Natural gas City gas Propane-butane gas Gas meter is equipped with pulse magnet as standard. Pulse transmitter can be added at any time (1 imp = 0,1 m3). Table 7. Technical Data 2G40L 2G65L Maximum flow rate m3/h 65 100 Minimum flow rate m3/h 0,40 0,65 Nominal flow rate m3/h 40 65 Cyclic volume dm3 65 65 Max working pressure bar 0,2 0,2 Index max indication m3/h 999999,99 999999,99 Starting flow rate dm3/h 32 32 bar 0,1 0,1 Fireproof up to 650 ºC according to EN 1359 Dimensions 437 720 ±2,5 666 ø100 ø 145 A [mm] ø 18 Kołn ierz ruchomy 560 796 ø 205 214 B [mm] 720 C [mm] 601 796 437 ø170 362 601 Curves of Typical error and Pressure loss 2G40L 2G65L 3 3 2 2 1 1 0 0 EN1359 /OIML R31 -1 -2 -3 -2 71/318/EWG 0 10 20 30 EN1359 /OIML R31 -1 40 50 60 65 -3 71/318/EWG 0 3.0 3.0 2.0 2.0 40 20 80 60 100 1 2 1 1.0 22 0 0 10 20 30 40 50 60 65 1.0 0 0 10 20 30 40 50 60 70 80 D [mm] 90 100 E [mm] 214 Weight 90 kg gas meters Smart gas meters with the remote reading They were designed for use within AMR and AMM systems, which will be beyond any doubt commonly developing in coming years. Gas meters fulfill conditions of valid norms and European standards, and for last years have been installed in EU countries in smart metering implementation process. Actually they are the most innovative products in their class in the market. from metering to data management 110 / 130 mm 100 / 110 / 130 mm 000 152,4 / 160 mm 220 mm 220 mm 250 mm 130 mm 280 / 300 mm UNIFO SERIES Type Maximum flow rate m /h 3 G1,6S G2,5S G4S G4S G6S G10S G16S 2,5 4 6 6 10 16 25 0,04 0,06 0,1 0,16 4 6 10 16 Minimum flow rate m3/h 0,016 0,016 / 0,025 0,016 / 0,025/ 0,04 Nominal flow rate m3/h 1,6 2,5 4 Cyclic volume 3 dm 1,2 1,2 1,2 2,2 2,2 5 5 Max working pressure bar 0,5 0,5 0,5 0,5 0,5 0,5 0,5 Index max indication m3/h 99999,999 99999,999 99999,999 99999,999 99999,999 999999,99 999999,99 Starting flow rate dm3/h 3 5 5 5 8 13 13 bar 0,1 0,1 0,1 0,1 0,1 Fireproof up to 650 ºC according to EN 1359 Thread Threaded connections may be manufactured acc. to any international norm. (ISO; ANSI; British Standard ect...) 15 gas meters Uniflo series Error curve correction allows for ±0,5% accuracy in full measurement range (standard requirement is ±1,5%) Built-in electronic temperature conversion Built-in valve for remote closing and safe opening of gas flow Data communication: wired or radio Data log of readings, alarms and events Standard IR interface for service (EN62056-21) Flexibility –– replaceable option board for communication –– software upgrade function Safety –– tamper protection and detection –– encryption AES-128 –– data log: hourly, daily and monthly Reliabilty –– optical detection of measuring unit –– resistance to interference of neodymium magnets –– resistance to interference in index housing –– index battery lifetime min. 10 years (calculated for 20 years) Certificate 2004/22/EC (MID) Compliance with norms: EN1359:1998 with annex B, EN1359-A1:2006, NTA 8130:2007 DSMR 2.2 (Netherlands), EN12405 (electronic index), OIML D11 (EMC) (electronic index) Dimensions Vc [dm3] A [mm] B [mm] C [mm] D [mm] E [mm] Weight 100 216 214 154 67 ~ 2,0 kg 110 216 / 200 214 / 205 to 211 160 / 154 67 / 70 ~ 2,0 kg 130 216 / 200 214 / 205 to 211 160 / 154 67 / 70 ~ 2,0 kg 152,4 235 268 170 73 ~ 3,0 kg 160 235 268 170 73 ~ 3,0 kg 220 283 222 169 72 ~ 2,0 kg Single pipe 231 289 180 78 3,0 kg 130 231 276 180 78 3,4 kg 220 326 286 183 79 3,4 kg 250 326 276 183 79 3,4 kg 280 395 345 207 93 6,8 kg 300 395 345 207 93 6,8 kg D A E 1,2 C Uniflo series Main features B 2,2 5 Curves of Pressure loss G1,6S | (1,2 dm3) G2,5S | (1,2 dm3) 2.0 1.5 1 1.0 2.0 2.0 1.5 1.5 1.0 2 2 0 0,5 1 1,5 2 2,5 1 1.0 1 2 2 1 0.5 0 G4S | (1,2 dm3) 0.5 0 0.5 0 1 2 3 4 0 0 1 2 3 4 5 6 from metering to data management G4S | (2,2 dm3) G6S | (2,2 dm3)g10S | (5 dm3) 2.0 2.0 1.5 1.0 1 1.5 2 1.0 1 2 3.0 2.0 1 2 0.5 0 1 4 3 2 6 5 0 0 0 1 2 3 4 5 6 0 4 8 12 16 G16S | (5 dm3) 3.0 1 2.5 2 2.0 1.5 1.0 0.5 0 0 5 10 15 20 25 New electronic index The new electronic index offers compact and smart design, innovative features - and is prepared for future requirements and international standards. Display: 9 digits, 0, 3 or 4 decimals (configurable) Alarm log Uniflo G4S electronic index has an auto diagnostic system, monitoring the conditions of the meter: Remaining life of battery Gas temperature, low and high limit* Temperature sensor error* High and high-high flow limit Gray-Code detection error Daily max. consumption error Self check error (hardware and software) Tamper detection (mechanical, magnetic) 30 latest alarms are stored with time stamp. *) Only for meter with temperature conversion Uniflo series 1.0 0.5 0 17 gas meters independent of the inlet gas temperature and the ambient temperature. Correct measurement of gas temperature improves the accuracy with up to 3%. Gray-code detection system Uniflo series Tamper proof The movement of the gas measuring unit is detected by a unique, High Frequency optical detection system, based on Gray-Code and 3 optical sensors on the PCB. This system offers high resolution, tamper proof ness and failsafe detection, fit for instant flow calculation and error curve correction. Excellent accuracy Final error code after correction Correction by linear interpolation Original meter error curve Mechanical tampering of the index is not possible, as moving parts in the index are reduced to a minimum. Removal of front cover will activate tamper alarm. The gas meter is not sensitive to normal magnetic fields. In case of extremely powerful magnets, a magnetic tamper alarm will be activated. Communication is secured by encryption (AES compatible) with individual encryption keys, and by detection of invalid communication format, activating alarm. Reverse gas flow will be stopped by mechanical lock in measuring unit, and reverse rotation will be detected by the “Gray-Code” and immediately activate an alarm. Also exceeding max. flow limit, or max. daily consumption limit will activate alarm. Alarms will be stored in the memory, with time stamp, to be transferred at the next meter reading, or immediately, when radio is used. Alarms can be reset remotely. Integrated valve (option) The initial error curve of the diaphragm gas meter is programmed into the micro-processor in the index at 3 flows: Qmin, 0.2 Qmax and Qmax. With the High Frequency Gray-Code detection, flow is calculated and consequent error by linear interpolation. The error curve of the measuring unit is corrected to approx. 0.1%. Temperature conversion (option) Temperature conversion may be performed for read out of base volume or energy. A unique temperature measurement system ensures a precise measurement of gas temperature inside the measuring unit, The meter may be supplied with built-in valve, offering remote closing of the gas flow after receiving the signal from back office. Because opening of gas valve may have important safety impacts (e.g. an opened unsecured gas cooker), Flonidan has developed a dedicated procedure both in hardware and software. After the communication unit has given the signal “Open valve”, customer may have to push a button on the index to reopen the valve (see flow chart “Open indirect”). If the meter after opening detects, within a given time frame, too high gas flow, the valve will automatically close again. Customer must first shut off gas consuming devices, before pushing the button again. Time frame and max. gas flow can be configured on customer specifications (See flow chart). Command for safe opening without customer intervention is also available (see flow chart “Open direct”) from metering to data management Close Open direct Open indirect Communication Unit gives command to close gas-valve Communication Unit gives command for direct opening of gas-valve Communication Unit gives command to indirect opening of gas-valve LCD changes between: „PRESS” and counter value Customer checkes on open gas-cooker etc. Gas-valve is closed Customer pushes Button on Index LCD indicates „ERROR” for 10 seconds LCD indicates: „OPENS” and gas-valve opens halfway Wait for pipe filling Wait for Flow control Valve opens fully, LCD indicates counter value and the customer has gas again NO YES Flow to hight? Gas-valve closes AMR (Automatic Meter Reading) The meter may be supplied with M-bus, wired (EN-13757-2) (standard with 2m cable) or wireless (EN13757-4). Exemplary configuration scheme of AMR system is shown below. Configuration and cost of the system depend on location of gas meters and technical requirements of the customer, therefore please contact our sales department to receive the suitable offer. Uniflo series LCD changes between: „NO GAS” and counter value 19 Apator Metrix S.A. ul. Piaskowa 3, 83-110 Tczew, Poland tel. +48.58 53 09 200, fax +48.58 53 09 300 metrix@metrix.pl Switchgear water meters heat meters Mining equipment gas meters Automation sensors www.apator.eu IT Systems metering solutions EN.00004/2010 electricity meters Surge Arresters