stair c plan 1 stair c section hh 2 stair c elevation 3 stair c section ii 4
Transcription
stair c plan 1 stair c section hh 2 stair c elevation 3 stair c section ii 4
2014 Copyright ________ EDWIN BRUCE A S S O C I A T E S. All designs drawings, and written material appearing herein, are protected and constitute original and unpublished work of the Architect and may not be copied, revised, re-used or disclosed without the written consent of the Architect. Equipment manufactured by others is excluded. Drawings and specifications are instruments of architectural service, and shall remain the property of the Architect. Use is restricted to the site for which they were prepared. MIN. CLEARANCE AT TRIM 1 1/2" MIN. EXISTING BUILDING TRIM 3'-2" 1 1/2" DIA. NEW HANDRAILS ATTACHED TO TOP OF EXISTING HAND RAILS, TOP OF NEW HANDRAILS TO BE AT HT. 34"-38" ABOVE TOP OF STAIR NOSINGS, TYP. REMOVE EXISTING WOOD RAILING AND WALL BRACKETS. 2 EXISTING HANDRAILS @ HT. 33 1/2" 3 1 6 2 5 The Alameda Suite 6 1 0 San Jose California 9 5 1 2 6 T: 408.995.5701 F: 408.995.5022 website: www.edwinbruce.com A-6 NOTE: OPEN RISERS ARE NOT PERMITTED PER CBC 11B-504.3. SEE NEW RISER DETAILS. 3'-2" 2 CODE: 34" - 38" 2'-10" EXISTING STEEL GUARDRAIL AT 42" ABOVE FLOOR LEVEL A-6 A-6 MIN. CLEARANCE AT TRIM CODE: 34" - 38" THE HANDGRIP PORTION OF HANDRAILS SHALL HAVE A SMOOTH SURFACE WITH NO SHARP CORNERS. EDGES SHALL HAVE A MIN. RADIUS OF 1/8". HANDRAILS SHALL NOT ROTATE WITHIN THEIR FITTINGS. 3'-0" 3'-0" 1'-2" TREAD 3'-0" 2'-11" CODE: 34" - 38" 2'-2" 6 1/4" 2'-11" EXISTING 3 1/2" x 3 1/2" POSTS EXTENSION BEYOND NOSING OF LAST RISER IS WIDTH OF TREAD + 12" MIN. TO START OF RADIUS. RETURN RAILING TO WALL. CORE DRILL EXISTING CONCRETE FOR NEW 1 1/2" DIA. STEEL POST. SET WITH NON-SHRINK GROUT, TYP. C SECTION H-H 2 STAIR SCALE = 1/2" = 1'-0" C ELEVATION 3 STAIR SCALE = 1/2" = 1'-0" NOTE: EXISTING STAIRS HAVE REQUIRED CONTRASTING STRIPE. VERIFY IN FIELD AND CORRECT TO CODE REQUIREMENTS IF THEY DO NOT HAVE MIN. 2" TO MAX. 4" WIDTH, PLACED PARALLEL TO AND NOT MORE THAN 1" BACK FROM NOSING. THE STRIPE SHALL EXTEND THE FULL WIDTH OF THE STEP OR UPPER APPROACH AND SHALL BE OF MATERIAL THAT IS AS SLIP RESISTANT AS THE OTHER TREADS OF THE STAIR. 3 A-6 REMOVE EXISTING STEEL RAILINGS 1'-0" MIN. 2'-2" 1'-0" MIN. /2" 11 R. CL EXISTING 3 1/2" x 3 1/2" POSTS MIN . UP FIRST FLOOR EXTENSION BEYOND NOSING OF LAST RISER IS WIDTH OF TREAD + 12" MIN. TO START OF RADIUS 12" MIN. EXTENSION BEYOND NOSING OF FIRST RISER TO START OF RADIUS 1 1/2" DIA. NEW STEEL HANDRAILS ATTACHED TO TOP OF EXISTING HAND RAILS, TOP OF NEW HANDRAILS TO BE AT HT. 34"-38" ABOVE TOP OF STAIR NOSINGS, TYP. EXISTING 3 1/2" x 3 1/2" POSTS EXISTING HANDRAILS @ HT. 33 1/2" EXTENSION BEYOND NOSING OF LAST RISER IS WIDTH OF TREAD + 12" MIN. TO START OF RADIUS 2'-9 1/2" 2'-2" 1 1/2" DIA. NEW STEEL HANDRAILS ATTACHED TO TOP OF EXISTING HAND RAILS, TOP OF NEW HANDRAILS TO BE AT HT. 34"-38" ABOVE TOP OF STAIR NOSINGS, TYP. CODE: 34" - 38" REMOVE EXISTING STEEL RAILING 38" EXISTING WOOD HANDRAILS @ HT. 32" 1 A-6 1855 SAN MIGUEL DR., WALNUT CREEK, CALIFORNIA 94596 4 A-6 2'-2" HILLTOP PROFESSIONAL BUILDING 9 1/2" 2'-11" SECOND FLOOR CODE: 34" - 38" I 3'-2" 6'-0" UP I 1 1/2" CLR. MIN. H H 1'-2" EXISTING STEEL GUARDRAIL AT 42" ABOVE FLOOR LEVEL 2'-2" 3'-0" 6 1/4" TREAD C PLAN 1 STAIR SCALE = 1/2" = 1'-0" N DATE C SECTION I-I 4 STAIR SCALE = 1/2" = 1'-0" 08.15.14 DRAWN GG/JO JOB NO 1321 A-4.0
Similar documents
PDF - Ron Blank and Associates, Inc.
professional education. As such, it does not include content that may be deemed or construed to be an approval or endorsement by the AIA or Ron Blank & Associates, Inc. of any material of construct...
More informationanti-slip safety stair walkway products
• Nosings shall terminate not more than 4" (101.6 mm) from ends of steps for poured concrete stairs; for concrete-filled steel pan stairs, nosings shall be full length of steps less 1/8" (3.05 mm) ...
More information