Bondstrand® 2000M/7000M - SMT tubes Bondstrand Épocal

Transcription

Bondstrand® 2000M/7000M - SMT tubes Bondstrand Épocal
Quick-Lock
1-16 inch
Bondstrand® 2000M/7000M
Glassfiber Reinforced Epoxy
(GRE) pipe systems for
marine service
with external pressure requirements
Taper/Taper
18-40 inch
Uses and applications
●
●
●
●
●
Ballast
Chlorination
Draining
Cargo line
Sanitary service & sewage
●
●
●
●
●
Portable discharge line
Stripping lines
Tankcleaning (salt water)
Fire protection mains
Various other applications
A complete library of Bondstrand pipe and fittings in PDS and PDMS-format is available
on CD-ROM. Please contact Ameron for details.
For specific fire protection requirements, an outher layer of passive fire protection is
available.
For pipe systems without external pressure requirements, please refer to Bondstrand 3400
product data (FP 835) or contact your Ameron representative.
Approvals
In 1993, IMO (International Maritime Organisation) issued a resolution (A.18/Res. 753)
covering acceptance criteria for assuring ship safety. Major certifying bodies have adopted
and implemented these Guidelines in their respective Rules and Regulations for the
Classification of Ships.
All Bondstrand pipe series used in the marine industry are designed and type-approved
by the below major certifying bodies. (A complete list is available, on request)
●
American Bureau of Shipping (ABS), U.S.A.;
●
Bureau Veritas, France;
●
Det Norske Veritas, Norway;
●
Germanischer Lloyd, Germany;
●
Lloyd’s Register, United Kingdom;
●
Nippon Kaiji Kyokai, Japan;
●
Registro Italiano Navale (RINA), Italy;
●
United States Coast Guard (USCG), U.S.A..
Characteristics
Maximum operating temperature: up to 121°C.
Pipe diameter: 1-40 inch (25-1000 mm).
Pipe system design for pressure ratings up to 16 bar.
ASTM D-2992 Hydrostatic Design Basis (Procedure B - service factor 0.5);
ASTM D-1599 Safety factor of 4:1. Design criteria for external pressure requirements are
in accordance with IMO regulations.
Bondstrand 2000M
ASTM D-2310 Classification: RTRP-11FW for static hydrostatic design basis; MDA cured.
ASTM D-2310 Classification: RTRP-11FX for static hydrostatic design basis; IPD cured.
Complies with ASTM F-1173 Classification.
Bondstrand 7000M
ASTM D-2310 Classification: RTRP-11AW for static hydrostatic design basis; MDA cured.
ASTM D-2310 Classification: RTRP-11AX for static hydrostatic design basis; IPD cured.
Complies with ASTM F-1173 Classification.
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 1 of 28. Printed in The Netherlands.
Table of Contents
GENERAL DATA
Adhesives ...................................................................................................................27
Conversions ...............................................................................................................28
Engineering design & installation data .......................................................................28
Hydrostatic testing ......................................................................................................28
Important notice ..........................................................................................................28
Joining system and configuration .................................................................................3
Mechanical properties ..................................................................................................4
Physical properties .......................................................................................................4
Pipe series ....................................................................................................................3
Pipe length ...................................................................................................................4
Pipe dimensions and weights .......................................................................................7
Pipe performance ..................................................................................................... 5-6
Span length ..................................................................................................................9
Surge Pressure ..........................................................................................................28
Ultimate Collapse Pressures ........................................................................................8
FITTINGS DATA
Adaptors ............................................................................................................... 26-27
Bell mouth ..................................................................................................................25
Couplings ...................................................................................................................22
Elbows ....................................................................................................................9-11
Expansion coupling ....................................................................................................26
Flanges ................................................................................................................. 20-22
Joint dimensions Quick-Lock® ....................................................................................8
Joint dimensions Taper/Taper .......................................................................................8
Laterals .......................................................................................................................17
Nipples .......................................................................................................................23
Reducers .............................................................................................................. 18-19
Saddles ............................................................................................................. 17 & 24
Specials ....................................................................................................................28
Tees .......................................................................................................................11-16
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 2 of 28. Printed in The Netherlands.
Pipe series
Pipe
Filament-wound Glassfiber Reinforced Epoxy (GRE) pipe for Bondstrand adhesivebonding systems. MDA (diaminodiphenylmethane) or IPD (isophoronediamine) cured.
Fittings
A wide range of lined filament-wound Glassfiber Reinforced Epoxy (GRE) fittings for
Bondstrand adhesive-bonding systems. For special fittings, not listed in this product
guide, please contact your Ameron representative.
Flanges
Filament-wound Glassfiber Reinforced Epoxy (GRE) heavy-duty flanges, hubbed and
stub-end flanges for Quick-Lock adhesive bonding systems. Standard flange drilling
patterns as per ANSI B16.5 (150 Lb). Other flange drilling patterns, such as ANSI B16.5
(> 150 Lb), DIN, ISO and JIS are also availabe.
Bondstrand® 2000M
Glassfiber Reinforced Epoxy (GRE) pipe system; IPD or MDA cured.
Standard 0.5 mm internal resin-rich reinforced liner.
Maximum operating temperature: 121°C for MDA cured and 93°C for IPD cured.
Maximum pressure rating: 16 bar.
Minimum pressure: full vacuum.
External Pressure Requirements: In accordance with IMO Regulations.
Bondstrand® 7000M (* conductive)
Glassfiber Reinforced Epoxy (GRE) pipe system; IPD or MDA cured.
Maximum operating temperature: 121°C for MDA cured and 93°C for IPD cured.
Maximum pressure rating: 16 bar.
Minimum pressure: full vacuum.
External Pressure Requirements: In accordance with IMO Regulations.
* Conductive
Our conductive pipe systems have been developed to prevent accumulation of potentially
dangerous levels of static electrical charges. Pipe, fittings and flanges contain high strength
conductive filaments. Together with a conductive adhesive this provides an electrically
continuous system.
Description
Pipe diameter
Joining system
Liner
**Temperature
Pressure Rating
*
**
Joining system &
configuration
Bondstrand® 2000M
1-40 inch
Quick-Lock 1-16 inch
Taper/Taper 18-40 inch
*0.5 mm
121°C
16 bar
Bondstrand® 7000M
1-40 inch
Quick-Lock 1-16 inch
Taper/Taper 18-40 inch
121°C
16 bar
Also available without liner;
Above 93°C, derate the pressure rating lineairly to 50% at 121°C.
Pipe
25-400 mm (1-16 inch):
Quick-Lock (straight/taper) adhesive joint with integral pipe stop in bell end.
End configuration: Integral Quick-Lock bell end x shaved straight spigot.
450-1000 mm (18-40 inch):
Taper/Taper adhesive joint.
End configuration: Integral Taper bell x shaved taper spigot
Fitting
25-400 mm (1-16 inch):
Quick-Lock (straight/ taper) adhesive joint with integral pipe stop in bell end.
End configuration: Integral Quick-Lock bell ends.
450-1000 mm (18-40 inch):
Taper/Taper adhesive joint.
End configuration: Integral Taper bell ends.
Flanges
25-1000 mm (1-40 inch):
Quick-Lock (straight/ taper) adhesive joint with integral pipe stop in bell end.
End configuration: Integral Quick-Lock bell end.
Note: * Pipe nipples, saddles and flanged fittings have different end configurations.
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 3 of 28. Printed in The Netherlands.
Typical pipe length
Nominal
Length*
Plant
[mm]
25-40
50-125
150
200
250
300-400
450-1000
Pipe Size
Asia Plant
[inch]
1-1½
2-5
6
8
10
12-16
18-40
Joining
Approximate overall
System
Europe
Quick-Lock
Quick-Lock
Quick-Lock
Quick-Lock
Quick-Lock
Quick-Lock
Taper/Taper
[m]
5.5
6.15
6.1
6.1/11.8
6.1/11.8
6.05/11.8
11.8
[m]
3.0
5.85/9.0
5.85/9.0
5.85/9.0
5.85/11.89
5.85/11.89
11.89
Method
Ameron
Ameron
—
—
—
ASTM D-792
* Tolerance +/- 50 mm.
Typical physical
properties
Pipe property
Thermal conductivity pipe wall
Thermal expansivity (lineair)
Flow coefficient
Absolute roughness
Density
Specific gravity
Units
W(m.K)
10-6 mm/mm °C
Hazen-Williams
10-6 m
kg/m3
-
Value
.33
18.0
150
5.3
1800
1.8
Typical mechanical
properties
Pipe property IPD cured
Bi-axial
Ultimate hoop stress at weeping
Circumferential
Hoop tensile strength
Hoop tensile modulus
Poisson’s ratio axial/hoop
Longitudinal
Axial tensile strength
Axial tensile modulus
Poisson’s ratio hoop/axial
Axial bending strength
Beam
Apparent elastic modulus
Hydrostatic Design Basis
Static
Units
21°C.
93°C.
Method
N/mm2
300
—
ASTM D-1599
N/mm2
N/mm2
—
380
23250
0.93
—
18100
1.04
ASTM D-2290
ASTM D-2290
Ameron
N/mm2
N/mm2
—
—
65
10000
0.40
80
50
7800
0.45
—
ASTM D-2105
ASTM D-2105
ASTM D-2105
Ameron
N/mm2
9200
7000
ASTM D-2925
N/mm2
148*
—
ASTM D-2992
(Proc. B.)
21°C.
93°C.
Method
N/mm2
250
—
ASTM D-1599
N/mm2
N/mm2
—
220
25200
0.65
—
0.81
ASTM D-2290
ASTM D-2290
Ameron
N/mm2
N/mm2
—
—
80
12500
0.40
85
65
9700
0.44
—
ASTM D-2105
ASTM D-2105
ASTM D-2105
Ameron
N/mm2
12500
8000
ASTM D-2925
N/mm2
124*
—
ASTM D-2992
(Proc. B.)
Pipe property MDA cured
Bi-axial
Ultimate hoop stress at weeping
Circumferential
Hoop tensile strength
Hoop tensile modulus
Poisson’s ratio axial/hoop
Longitudinal
Axial tensile strength
Axial tensile modulus
Poisson’s ratio hoop/axial
Axial bending strength
Beam
Apparent elastic modulus
Hydrostatic Design Basis
Static
Units
* At 65°C.
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 4 of 28. Printed in The Netherlands.
Typical pipe performance
.
Bondstrand 2000M (MDA cured) at 21°C.
Nominal
Pipe
Size
[mm]
25
40
50
80
100
125
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
[inch]
1
1½
2
3
4
5
6
8
10
12
14
16
18
20
24
28
30
32
36
40
STIS
Stifness
Factor
Pipe
Stiffness
[kN/m2]
2079.1
618.1
350.6
102.2
110.8
57.7
33.4
35.5
36.6
35.9
36.8
36.9
36.2
36.3
36.6
36.9
36.8
37.1
36.8
37.7
[lb.in]
502
502
554
554
1281
1281
1281
3092
6375
10627
13548
20308
28265
38976
67877
121531
148680
182139
256919
361759
[psi]
16187
4812
2729
796
863
449
260
276
285
280
286
287
282
283
285
288
286
289
286
294
STIS
Stifness
Factor
Pipe
Stiffness
[kN/m2]
2087.4
620.6
352.0
102.6
111.3
57.9
33.5
35.6
36.8
36.1
36.9
37.1
36.3
36.5
36.6
36.9
36.8
37.1
36.8
37.7
[lb.in]
504
504
556
556
1286
1286
1286
3104
6400
10669
13602
20389
28378
39130
68147
122013
149270
182862
257939
363195
[psi]
16251
4831
2740
799
866
451
261
277
286
281
287
289
283
284
285
289
288
290
288
295
Bondstrand 2000M (IPD-cured) at 21°C.
Nominal
Pipe
Size
[mm]
25
40
50
80
100
125
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
[inch]
1
1½
2
3
4
5
6
8
10
12
14
16
18
20
24
28
30
32
36
40
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 5 of 28. Printed in The Netherlands.
Typical pipe performance
Bondstrand 7000M (MDA-cured) at 21°C.
Nominal
Pipe
Size
[mm]
25
40
50
80
100
125
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
[inch]
1
1½
2
3
4
5
6
8
10
12
14
16
18
20
24
28
30
32
36
40
STIS
Stifness
Factor
Pipe
Stiffness
[kN/m2]
3142.4
949.6
534.7
157.3
154.4
80.6
46.7
39.4
38.2
37.2
38.0
37.2
38.0
37.2
36.7
37.1
36.9
37.3
36.9
37.9
[lb.in]
797
797
867
867
1809
1809
1809
3092
6375
10627
13548
20308
28265
38976
67877
121531
148680
182139
256919
361759
[psi]
24464
7393
4162
1225
1202
627
363
276
285
280
286
287
282
283
285
288
286
289
286
294
STIS
Stifness
Factor
Pipe
Stiffness
[kN/m2]
3154.9
953.3
536.8
157.9
155.0
80.9
46.9
35.6
36.8
36.1
36.9
37.1
36.3
36.5
36.7
37.1
36.9
37.3
36.9
37.9
[lb.in]
800
800
871
871
1816
1816
1816
3104
6400
10669
13602
20389
28378
39130
68147
122013
149270
182862
257939
363195
[psi]
24561
7422
4179
1230
1207
630
365
277
286
281
287
289
283
284
286
289
288
290
288
295
Bondstrand 7000M (IPD-cured) at 21°C.
Nominal
Pipe
Size
[mm]
25
40
50
80
100
125
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
[inch]
1
1½
2
3
4
5
6
8
10
12
14
16
18
20
24
28
30
32
36
40
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 6 of 28. Printed in The Netherlands.
Typical pipe dimensions
and weights
Bondstrand 2000M.
Nominal
Pipe
Size
[mm] [inch]
25
1
40
1½
50
2
80
3
100
4
125
5
150
6
200
8
250
10
300
12
400
14
400
16
450
18
500
20
600
24
700
28
750
30
800
32
900
36
1000
40
Pipe
Minimum Average
Inside Struct. Wall
Pipe
Diameter Thickness [t] Weight
[mm]
[mm]
[kg/m]
27.1
3.0
0.7
42.1
3.0
1.3
53.0
3.1
1.3
81.8
3.1
1.8
105.2
4.1
3.1
131.9
4.1
3.5
159.0
4.1
4.6
208.8
5.5
7.4
262.9
7.0
12
313.7
8.3
17
337.6
9.0
19
385.8
10.3
25
433.8
11.5
32
482.1
12.8
39
578.6
15.4
56
700.0
18.7
75
750.0
20.0
93
800.0
21.4
102
900.0
24.0
132
1000.0
26.9
165
MDA
RTRP-11 FW1-2112
RTRP-11 FW1-2112
RTRP-11FW1-2112
RTRP-11FW1-2112
RTRP-11FW1-2113
RTRP-11FW1-2113
RTRP-11FW1-2113
RTRP-11FW1-2116
RTRP-11FW1-2116
RTRP-11FW1-2116
RTRP-11FW1-2116
RTRP-11FW1-2116
RTRP-11FW1-2116
RTRP-11FW1-2116
RTRP-11FW1-2116
RTRP-11FW1-2116
RTRP-11FW1-2116
RTRP-11FW1-2116
RTRP-11FW1-2116
RTRP-11FW1-2116
Designation
per ASTM
D-2966
IPD
FX1-3112
FX1-3112
FX1-3112
FX1-3112
FX1-3113
FX1-3113
FX1-3113
FX1-3116
FX1-3116
FX1-3116
FX1-3116
FX1-3116
FX1-3116
FX1-3116
FX1-3116
FX1-3116
FX1-3116
FX1-3116
FX1-3116
FX1-3116
MDA
RTRP-11AW1-2112
RTRP-11AW1-2112
RTRP-11AW1-2112
RTRP-11AW1-2112
RTRP-11AW1-2113
RTRP-11AW1-2113
RTRP-11AW1-2113
RTRP-11AW1-2116
RTRP-11AW1-2116
RTRP-11AW1-2116
RTRP-11AW1-2116
RTRP-11AW1-2116
RTRP-11AW1-2116
RTRP-11AW1-2116
RTRP-11AW1-2116
RTRP-11AW1-2116
RTRP-11AW1-2116
RTRP-11AW1-2116
RTRP-11AW1-2116
RTRP-11AW1-2116
Designation
per ASTM
D-2966
IPD
AX1-3112
AX1-3112
AX1-3112
AX1-3112
AX1-3113
AX1-3113
AX1-3113
AX1-3116
AX1-3116
AX1-3116
AX1-3116
AX1-3116
AX1-3116
AX1-3116
AX1-3116
AX1-3116
AX1-3116
AX1-3116
AX1-3116
AX1-3116
Bondstrand 7000M.
Nominal
Pipe
Size
[mm] [inch]
25
1
40
1½
50
2
80
3
100
4
125
5
150
6
200
8
250
10
300
12
350
14
400
16
450
18
500
20
600
24
700
28
750
30
800
32
900
36
1000
40
Pipe
Minimum Average
Inside Struct. Wall
Pipe
Diameter Thickness [t] Weight
[mm]
[mm]
[kg/m]
27.1
3.5
0.7
42.1
3.5
1.3
53.0
3.6
1.3
81.8
3.6
1.8
105.2
4.6
3.1
131.9
4.6
3.5
159.0
4.6
4.6
208.8
5.5
7.4
262.9
7.0
12
313.7
8.3
17
337.6
9.0
19
385.8
10.3
25
433.8
11.5
32
482.1
12.8
39
578.6
15.4
56
700.0
18.7
75
750.0
20.0
93
800.0
21.4
102
900.0
24.0
132
1000.0
26.9
165
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 7 of 28. Printed in The Netherlands.
Ultimate collapse pressure
Ultimate collapse pressure (ultimate short term external failure pressure) at 21º C.
Nominal
Pipe
Size
[mm]
[inch]
25
1
40
1½
50
2
80
3
100
4
125
5
150
6
200
8
250
10
300
12
350
14
400
16
450
18
500
20
600
24
700
28
750
30
800
32
900
36
1000
40
Internal
Pressure
static*
[bar]
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
2000M
MDA
2000M
IPD
7000M
MDA
7000M
IPD
[bar]
491
160
95
29
31
16.5
9.7
10.3
10.7
10.5
10.7
10.7
10.5
10.6
10.7
10.8
10.7
10.8
10.7
11.0
[bar]
491
160
95
29
31
16.5
9.7
10.3
10.7
10.5
10.7
10.7
10.5
10.6
10.7
10.8
10.7
10.8
10.7
11.0
[bar]
714
239
141
44
43
23
13.5
10.3
10.7
10.5
10.7
10.7
10.5
10.6
10.7
10.8
10.7
10.8
10.7
11.0
[bar]
714
239
141
44
43
23
13.5
10.3
10.7
10.5
10.7
10.7
10.5
10.6
10.7
10.8
10.7
10.8
10.7
11.0
Max.
Spigot
Min.
L
[mm]
28.5
33.5
49.0
49.0
49.0
58.5
59.0
65.0
71.0
78.0
89.0
103.0
L
[mm]
31.0
36.0
52.0
52.0
52.0
61.5
62.0
68.0
74.0
81.0
93.0
106.0
* Up to 93°C.
Quick-Lock® dimensions
Nominal
Length
Pipe
Max.
Size
[mm]
[inch]
25
1
40
1½
50
2
80
3
100
4
125
5
150
6
200
8
250
10
300
12
350
14
400
16
Insertion
Depth
(Ds)
[mm]
27
32
46
46
46
57
57
64
70
76
89
102
Sd
[mm]
32.6
47.5
59.2
87.6
112.5
139.5
166.2
217.1
271.3
322.2
353.8
404.1
Spigot Diameter
Min.
Sd
[mm]
32.9
47.8
59.6
88.0
112.9
139.9
166.6
217.5
271.7
322.6
354.2
404.5
Dimensions for Quick-Lock Spigots for bonding HD Flanges.
450
500
600
700
750
800
900
1000
Taper/Taper dimensions
18
20
24
28
30
32
36
40
Dia of Straight
Spigot [Sd]
455.8
506.6
608.2
736.3
788.4
840.5
943.4
1051.4
111
111
127
152
165
178
163
230
Dimensions for adhesive Taper spigots for adhesive Taper/Taper joints.
Nominal
Pipe
Size
[mm]
450
500
600
700
750
800
900
1000
[inch]
18
20
24
28
30
32
36
40
Taper
Angle
Insertion
Depth
X
[degrees]
2.5
2.5
3.5
1.75
1.75
1.75
1.75
1.75
Ds
[mm]
114
127
178
178
178
178
203
410
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 8 of 28. Printed in The Netherlands.
Nominal
Spigot
Nose Thickn.
nose
[mm]
4.6
5.0
3.8
6.4
4.2
8.9
5.6
8.1
Dia of
Spigot
at Nose
Sd
[mm]
443.0
492.2
586.3
712.9
758.4
817.8
911.3
1016.3
Span length
Bondstrand 2000M.
Nominal
Pipe Size
[mm]
25
40
50
80
100
125
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
[inch]
1
1½
2
3
4
5
6
8
10
12
14
16
18
20
24
28
30
32
36
40
Bondstrand 7000M.
25
1
40
1½
50
2
80
3
100
4
125
5
150
6
200
8
250
10
300
12
350
14
400
16
450
18
500
20
600
24
700
28
750
30
800
32
900
36
1000
40
Single
Span*
[m]
2.6
2.9
3.1
3.5
4.0
4.3
4.5
5.1
5.8
6.3
6.5
7.0
7.4
7.7
8.5
9.3
9.6
10.0
10.5
11.1
2.5
2.9
3.1
3.5
4.0
4.3
4.5
5.0
5.7
6.2
6.4
6.9
7.3
7.7
8.4
9.3
9.6
9.9
10.5
11.1
MDA Contininuous
Span*
[m]
3.3
3.7
4.0
4.5
5.1
5.4
5.7
6.5
7.3
8.0
8.3
8.8
9.3
9.8
10.8
11.8
12.2
12.7
13.4
14.1
Single IPD Continuous
Span*
Span*
[m]
[m]
2.4
3.0
2.7
3.4
2.9
3.7
3.3
4.2
3.7
4.7
4.0
5.0
4.2
5.3
4.8
6.1
5.3
6.8
5.8
7.4
6.0
7.7
6.4
8.2
6.8
8.7
7.2
9.1
7.9
10.0
8.6
11.0
8.9
11.3
9.2
11.7
9.8
12.4
10.3
13.1
MDA
3.3
3.8
4.1
4.5
5.2
5.6
5.9
6.5
7.3
8.0
8.3
8.8
9.3
9.8
10.8
11.8
12.2
12.7
13.4
14.1
IPD
3.0
3.4
3.7
4.2
4.7
5.0
5.3
5.9
6.7
7.3
7.6
8.1
8.6
9.0
9.9
10.9
11.3
11.7
12.4
13.0
2.4
2.7
2.9
3.3
3.7
4.0
4.2
4.7
5.3
5.7
6.0
6.4
6.7
7.1
7.8
8.6
8.9
9.2
9.7
10.3
* Span recommendations are based on pipes filled with water having a density of 1000 kg/m3
and include no provisions for weights caused by valves, flanges or other heavy objects.
Elbows 90º
Quick-Lock
Taper/Taper
Filament-wound 90º elbows with integral Quick-Lock (1-16 inch) or
Taper/Taper (18-40 inch) socket ends for adhesive bonding.
Nominal
Pipe Size
[mm]
25
40
50
80
100
125
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
[inch]
1
1½
2
3
4
5
6
8
10
12
14
16
18
20
24
28
30
32
36
40
Laying
Length (LL)
[mm]
65
81
76
114
152
195
229
305
381
457
359
397
458
508
584
711
762
813
915
1040
Overall
Length (OL)
[mm]
92
113
122
160
198
252
286
369
451
533
448
499
572
635
762
889
940
991
1118
1450
Max. Working
Pressure
[bar]
20
20
20
20
20
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
Average
Weight
[kg]
0.3
0.4
0.5
1.1
1.6
2.7
3.6
6.8
11.0
18.0
26.0
31.0
53.0
65.0
122.0
205.0
243.0
330.0
417.0
489.0
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 9 of 28. Printed in The Netherlands.
Elbows ANSI 90º
short radius
Filament-wound 90° elbows with integral Quick-Lock male ends.*
Nominal
Pipe
Size
[mm]
50
80
100
150
200
250
300
[inch]
2
3
4
6
8
10
12
Laying
Length
(LL)
[mm]
110
135
160
198
224
275
300
Maximum
Working
Pressure
[bar]
12
12
12
12
12
12
12
Average
Weight
Maximum
Working
Pressure
[bar]
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
Average
Weight
[kg]
0.4
0.7
1.0
2.4
3.9
6.3
13.3
* Also available with flanges.
Elbows 45º
Filament-wound 45° Quick-Lock (1-16 inch) or
Taper/Taper (18-40 inch) socket ends for adhesive bonding.
Taper/Taper
Nominal
Pipe
Size
[mm]
25
40
50
80
100
125
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
Elbows ANSI 45º
Filament-wound 45°elbows with integral Quick-Lock male ends.*
Quick-Lock
Nominal
Pipe
Size
[mm]
50
80
100
150
200
250
300
[inch]
1
1½
2
3
4
5
6
8
10
12
14
16
18
20
24
28
30
32
36
40
[inch]
2
3
4
6
8
10
12
Laying
Length
(LL)
[mm]
22
29
35
51
64
84
95
127
159
191
121
137
191
210
252
295
322
337
400
450
Laying
Length
(LL)
[mm]
60
71
97
121
134
159
186
* Also available with flanges.
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 10 of 28. Printed in The Netherlands.
Overall
Length
(OL)
[mm]
49
61
81
97
110
141
152
191
229
267
210
239
305
337
430
473
500
515
603
860
Maximum
Working
Pressure
[bar]
12
12
12
12
12
12
12
[kg]
0.2
0.3
0.4
0.8
1.1
1.8
2.4
4.3
7.3
11.0
17.0
20.0
33.0
40.0
82.0
140.0
164.0
283.0
283.0
334.0
Average
Weight
[kg]
0.2
0.4
0.9
1.9
3.9
8.3
10.0
Elbows 22½º
Filament-wound 22½°elbows with integral Quick-Lock socket ends
for adhesive bonding.
Nominal
Pipe
Size
[mm]
25
40
50
80
100
125
150
200
250
300
350
400
Equal Tees
[inch]
1
1½
2
3
4
5
6
8
10
12
14
16
Taper/Taper
Overall
Length
(OL)
[mm]
36
41
59
67
75
100
100
121
137
152
172
191
Maximum
Working
Pressure
[bar]
16
16
16
16
16
16
16
16
16
16
16
16
Average
Weight
[kg]
0.1
0.2
0.5
0.7
1.0
1.4
1.9
3.9
5.9
10.4
12.0
14.0
Filament-wound equal Tee with integral Quick-Lock (1-16 inch) or
Taper/Taper (18-40 inch) socket ends for adhesive bonding.
Nominal
Pipe
Size
Quick-Lock
Laying
Length
(LL)
[mm]
9
9
13
21
29
43
43
57
67
76
83
89
[mm]
25
40
50
80
100
125
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
[inch]
1
1½
2
3
4
5
6
8
10
12
14
16
18
20
24
28
30
32
36
40
Laying
Length
total run
(LL1)
[mm]
54
60
128
172
210
254
286
356
432
508
534
584
648
712
838
964
1016
1090
1220
1416
Overall
Length
total run
(OL1)
[mm]
108
124
220
264
302
368
400
484
572
660
712
788
876
966
1194
1320
1372
1446
1626
2236
Laying
Length
branch
(LL2)
[mm]
27
30
64
86
105
127
143
178
216
254
267
292
324
356
419
482
508
545
610
708
Overall
Length
branch
(OL2)
[mm]
54
62
110
132
151
184
200
242
286
330
356
394
438
483
597
660
686
723
813
1118
Maximum
Working
Pressure
Average
Weight
[bar]
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
[kg]
0.2
0.4
1.0
1.8
2.5
5.0
6.7
10.0
18.0
29.0
37.0
56.0
69.0
92.0
168.0
285.0
337.0
459.0
581.0
686.0
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 11 of 28. Printed in The Netherlands.
Reducing Tees
Filament-wound standard and fabricated reducing tees with integral
Quick-Lock (1-16 inch) socket ends for adhesive bonding.
Nominal
Pipe
Size
(runxrunxbranch)
Standard
Fabricated
[mm]
40x40x25
50x50x25
50x50x40
80x80x25
80x80x40
80x80x50
100x100x25
100x100x40
100x100x50
100x100x80
125x125x50
125x125x80
125x125x100
150x150x25
150x150x40
150x50x50
150x150x80
150x150x100
150x150x125
200x200x25
200x200x40
200x200x50
200x200x80
200x200x100
200x200x125
200x200x150
250x250x25
250x250x40
250x250x50
250x250x80
250x250x100
250x250x125
250x250x150
250x250x200
300x300x25
300x300x40
300x300x50
300x300x80
300x300x100
300x300x150
300x300x200
300x300x250
350x350x25
350x350x40
350x350x50
350x350x80
350x350x100
350x350x150
350x350x200
350x350x250
350x350x300
400x400x25
400x400x40
400x400x50
400x400x80
400x400x100
400x400x150
400x400x200
400x400x250
400x400x300
400x400x350
[inch]
1½x1½x1
2x2x1
2x2x1½
3x3x1
3x3x1½
3x3x2
4x4x1
4x4x1½
4x4x2
4x4x3
5x5x2
5x5x3
5x5x4
6x6x1
6x6x1½
6x6x2
6x6x3
6x6x4
6x6x5
8x8x1
8x8x1½
8x8x2
8x8x3
8x8x4
8x8x5
8x8x6
10x10x1
10x10x1½
10x10x2
10x10x3
10x10x4
10x10x5
10x10x6
10x10x8
12x12x1
12x12x1½
12x12x2
12x12x3
12x12x4
12x12x6
12x12x8
12x12x10
14x14x1
14x14x1½
14x14x2
14x14x3
14x14x4
14x14x6
14x14x8
14x14x10
14x14x12
16x16x1
16x16x1½
16x16x2
16x16x3
16x16x4
16x16x6
16x16x8
16x16x10
16x16x12
16x16x14
Laying
Length
(LL1)
Overall
Length
(OL1)
Laying
Length
(LL2)
[mm]
30
64
64
86
86
86
72
89
105
105
127
127
127
83
101
143
143
143
143
84
101
116
178
178
178
178
83
100
115
115
216
216
216
216
84
102
117
117
254
254
254
254
81
99
114
114
114
267
267
267
267
85
103
118
118
118
292
292
292
292
292
[mm]
62
110
110
132
132
132
118
136
151
151
184
184
184
140
158
200
200
200
200
148
165
180
242
242
242
242
153
170
185
185
286
286
286
286
160
178
193
193
330
330
330
330
170
188
203
203
203
356
356
356
356
187
205
220
220
220
394
394
394
394
394
[mm]
30
57
57
76
76
76
194
194
89
98
102
111
118
221
221
114
124
130
136
245
246
246
149
162
168
168
273
273
273
273
184
194
194
203
298
298
298
298
206
219
229
241
314
314
314
314
314
244
254
267
279
338
338
338
338
338
264
273
283
295
292
half run
half run
branch
Overall Maximum Average
Length Working Weight
(OL2) Pressure
branch
[mm]
57
84
89
103
108
122
221
226
135
144
148
157
164
248
253
160
170
176
193
272
278
292
195
208
225
225
300
305
320
320
230
251
251
267
325
330
344
344
252
276
293
311
341
346
361
361
361
301
318
337
355
365
370
384
384
384
321
337
353
371
381
[bar]
20
20
20
20
20
20
20
20
20
20
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
Note: Regular numbers are filament wound tees; Italic numbers are fabricated tees;
Filament-wound standard and fabricated reducing tees with integral.
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 12 of 28. Printed in The Netherlands.
[kg]
0.6
0.9
1.0
1.6
1.6
1.7
7.5
9.0
2.1
2.3
3.4
4.0
4.6
11.7
13.8
5.4
6.0
6.2
6.5
15.0
17.5
19.9
9.1
9.7
10.6
11.4
18.1
21.0
24.0
24.0
14.8
15.2
15.5
16.5
21.2
25.0
29.0
29.0
21.0
22.0
23.0
24.0
24.0
28.0
31.0
31.0
31.0
29.0
30.0
32.0
34.0
29.0
33.0
37.0
37.0
37.0
37.0
38.0
41.0
45.0
49.0
Reducing Tees
Taper/Taper (18-40 inch) socket ends for adhesive bonding.
Nominal
Pipe
Size
(runxrunxbranch)
[mm]
450x450x25
450x450x40
450x450x50
450x450x80
450x450x100
450x450x150
450x450x200
450x450x250
450x450x300
450x450x350
450x450x400
500x500x25
500x500x40
500x500x50
500x500x80
500x500x100
500x500x150
500x500x250
500x500x300
500x500x350
500x500x400
500x500x450
600x600x25
600x600x40
600x600x50
600x600x80
600x600x100
600x600x150
600x600x200
600x600x250
600x600x300
600x600x350
600x600x400
600x600x450
600x600x500
700x700x25
700x700x40
700x700x50
700x700x80
700x700x100
700x700x150
700x700x350
700x700x400
700x700x450
700x700x500
700x700x600
750x750x25
750x750x40
750x750x50
750x750x80
750x750x100
750x750x150
750x750x300
750x750x350
750x750x400
750x750x450
750x750x500
750x750x600
[inch]
18x18x1
18x18x1½
18x18x2
18x18x3
18x18x4
18x18x6
18x18x8
18x18x10
18x18x12
18x18x14
18x18x16
20x20x1
20x20x1½
20x20x2
20x20x3
20x20x4
20x20x6
20x20x10
20x20x12
20x20x14
20x20x16
20x20x18
24x24x1
24x24x1½
24x24x2
24x24x3
24x24x4
24x24x6
24x24x8
24x24x10
24x24x12
24x24x14
24x24x16
24x24x18
24x24x20
28x28x1
28x28x1½
28x28x2
28x28x3
28x28x4
28x28x6
28x28x14
28x28x16
28x28x18
28x28x20
28x28x24
30x30x1
30x30x1½
30x30x2
30x30x3
30x30x4
30x30x6
30x30x12
30x30x14
30x30x16
30x30x18
30x30x20
30x30x24
Laying
Length
(LL1)
Overall
Length
(OL1)
Laying
Length
(LL2)
[mm]
88
88
88
100
113
138
324
324
324
324
324
88
88
88
100
113
138
356
356
356
356
356
88
88
88
100
113
138
419
419
419
419
419
419
419
88
88
88
100
113
138
482
482
482
482
482
88
88
88
100
113
138
508
508
508
508
508
508
[mm]
202
202
202
214
227
252
438
438
438
438
438
215
215
215
227
240
265
483
483
483
483
483
266
266
266
278
291
316
597
597
597
597
597
597
597
266
266
266
278
291
316
660
660
660
660
660
266
266
266
278
291
316
686
686
686
686
686
686
[mm]
358
358
358
358
358
367
306
319
319
317
319
382
382
382
382
382
391
344
345
343
344
350
430
430
430
430
430
439
412
386
408
394
395
413
406
491
491
491
491
491
500
490
500
500
506
506
516
516
516
516
516
525
756
722
698
488
495
481
half run
half run
branch
Overall Maximum Average
Length Working Weight
(OL2) Pressure
branch
[mm]
385
390
404
404
404
424
370
389
395
406
421
409
414
428
428
428
448
414
421
432
446
464
457
462
476
476
476
496
476
456
484
483
497
527
533
518
523
537
537
537
557
579
602
614
633
684
543
548
562
562
562
582
832
811
800
602
622
659
[bar]
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
14
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
[kg]
31.0
31.0
22.0
35.0
38.0
45.0
53.0
60.0
67.0
66.0
69.0
35.0
35.0
36.0
39.0
43.0
50.0
77.0
82.0
85.0
85.0
89.0
51.0
51.0
52.0
56.0
61.0
69.0
78.0
85.0
85.0
101.0
123.3
137.0
156.0
59.0
59.0
59.0
64.0
70.0
80.0
147.0
166.0
189.0
210.0
252.0
63.0
63.0
63.0
69.0
74.0
85.0
118.0
157.0
178.0
202.0
225.0
270.0
Note: Regular numbers are filament wound tees; Italic numbers are fabricated tees.
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 13 of 28. Printed in The Netherlands.
Reducing Tees (C’tnd)
Filament-wound standard and fabricated reducing tees with integral
Taper/Taper (18-40 inch) socket ends for adhesive bonding.
Nominal
Pipe
Size
(runxrunxbranch)
Standard
Fabricated
[mm]
[inch]
800x800x25
32x32x1
800x800x40 32x32x1½
800x800x50
32x32x2
800x800x80
32x32x3
800x800x100 32x32x4
800x800x150 32x32x6
800x800x500 32x32x20
800x800x600 32x32x24
800x800x700 32x32x28
800x800x750 32x32x30
900x900x25
36x36x1
900x900x40 36x36x1½
900x900x50
36x36x2
900x900x80
36x36x3
900x900x100 36x36x4
900x900x150 36x36x6
900x900x400 36x36x16
900x900x450 36x36x18
900x900x500 36x36x20
900x900x600 36x36x24
900x900x700 36x36x28
900x900x750 36x36x30
1000x1000x400 40x40x1
1000x1000x45040x40x1½
1000x1000x500 40x40x2
1000x1000x600 40x40x3
1000x1000x60040x40x24
1000x1000x70040x40x28
1000x1000x75040x40x30
1000x1000x80040x40x32
1000x1000x90040x40x36
Laying
Length
(LL1)
Overall
Length
(OL1)
Laying
Length
(LL2)
[mm]
88
88
88
100
113
138
545
545
545
545
88
88
88
100
113
138
610
610
610
610
610
610
120
120
120
132
708
708
708
708
708
[mm]
266
266
266
278
291
316
723
723
723
723
291
291
291
303
316
341
813
813
813
813
813
813
530
530
530
542
1118
1118
1118
1118
1118
[mm]
541
541
541
541
541
550
523
523
532
534
591
591
591
591
591
600
563
563
563
541
570
584
641
641
641
641
593
632
633
652
652
half run
half run
branch
Overall Maximum Average
Length Working Weight
(OL2) Pressure
branch
[mm]
568
573
587
587
587
607
650
701
710
712
618
623
637
637
637
657
665
677
690
719
748
762
668
673
687
687
771
810
811
830
855
[bar]
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
Note: Regular numbers are filament wound tees; Italic numbers are fabricated tees.
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 14 of 28. Printed in The Netherlands.
[kg]
66.0
67.0
67.0
73.0
79.0
90..0
257.0
310.0
348.0
387.0
78.0
78.0
78.0
85.0
92.0
105.0
270.0
290.0
323.0
387.0
459.0
484.0
92.0
92.0
92.0
100.0
457.0
541.0
571.0
605.0
634.0
Fabricated Reducing Tees
with Flanged Branch
Fabricated Reducing tees with integral Quick-Lock (1-16 inch) socket ends and
flanged branch.
Nominal
Pipe
Size
(runxrunxbranch)
[mm]
100x100x25
100x100x40
150x150x25
150x150x40
200x200x25
200x200x40
200x200x50
250x250x25
250x250x40
250x250x50
250x250x80
300x300x25
300x300x40
300x300x50
300x300x80
350x350x25
350x350x40
350x350x50
350x350x80
350x350x100
400x400x25
400x400x40
400x400x50
400x400x80
400x400x100
[inch]
4x4x1
4x4x1½
6x6x1
6x6x1½
8x8x1
8x8x1½
8x8x2
10x10x1
10x10x1½
10x10x2
10x10x3
12x12x1
12x12x1½
12x12x2
12x12x3
14x14x1
14x14x1½
14x14x2
14x14x3
14x14x4
16x16x1
16x16x1½
16x16x2
16x16x3
16x16x4
Laying
Length
(LL1)
Overall
Length
(OL1)
Laying
Length
(LL2)
[mm]
72
89
83
101
84
101
116
83
100
115
115
84
102
117
117
81
99
114
114
114
85
103
118
118
118
[mm]
118
135
140
158
148
165
180
153
170
185
185
160
178
193
193
170
188
203
203
203
187
205
220
220
220
[mm]
225
230
252
257
276
281
295
303
308
322
323
329
334
348
349
344
349
363
369
364
369
374
388
389
389
half run
half run
branch
Maximum
Average
Working
Weight
Pressure with flange
[bar]
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
CL150
[kg]
8.0
9.7
12.2
14.5
15.5
18.2
21.4
18.6
22.0
25.6
26.3
22.3
26.1
30.2
30.9
24.3
28.4
32.7
33.4
34.2
29.1
33.8
38.5
39.2
39.9
Note: Other sizes, or multiple size branched tees available on request. Please contact Ameron.
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 15 of 28. Printed in The Netherlands.
Fabricated Reducing Tees
with Flanged Branch
Fabricated Reducing tees with integral Taper/Taper (18-40 inch) socket ends and
flanged branch.
Nominal
Pipe
Size
(runxrunxbranch)
[mm]
[inch]
450x450x25
18x18x1
450x450x40 18x18x1½
450x450x50
18x18x2
450x450x80
18x18x3
450x450x100 18x18x4
450x450x150 18x18x6
500x500x25
20x20x1
500x500x40 20x20x1½
500x500x50
20x20x2
500x500x80
20x20x3
500x500x100 20x20x4
500x500x150 20x20x6
600x600x25
24x24x1
600x600x40 24x24x1½
600x600x50
24x24x2
600x600x80
24x24x3
600x600x100 24x24x4
600x600x150 24x24x6
700x700x25
28x28x1
700x700x40 28x28x1½
700x700x50
28x28x2
700x700x80
28x28x3
700x700x100 28x28x4
700x700x150 28x28x6
750x750x25
30x30x1
750x750x40 30x30x1½
750x750x50
30x30x2
750x750x80
30x30x3
750x750x100 30x30x4
750x750x150 30x30x6
800x800x25
32x32x1
800x800x40 32x32x1½
800x800x50
32x32x2
800x800x80
32x32x3
800x800x100 32x32x4
800x800x150 32x32x6
900x900x25
36x36x1
900x900x40 36x36x1½
900x900x50
36x36x2
900x900x80
36x36x3
900x900x100 36x36x4
900x900x150 36x36x6
1000x1000x25 40x40x1
1000x1000x4040x40x1½
1000x1000x50 40x40x2
1000x1000x80 40x40x3
Laying
Length
(LL1)
Overall
Length
(OL1)
Laying
Length
(LL2)
[mm]
88
88
88
100
113
138
88
88
88
100
113
138
88
88
88
100
113
138
88
88
88
100
113
138
88
88
88
100
113
138
88
88
88
100
113
138
88
88
88
100
113
138
120
120
120
132
[mm]
202
202
202
214
227
252
215
215
215
227
240
265
266
266
266
278
291
316
266
266
266
278
291
316
266
266
266
278
291
316
266
266
266
278
291
316
291
291
291
303
316
341
530
530
530
542
[mm]
388
394
408
409
409
430
412
418
432
433
433
454
460
467
480
481
481
502
521
527
541
542
542
563
546
552
566
567
567
588
571
576
590
590
590
610
621
627
641
642
642
663
672
677
691
692
half run
half run
branch
Maximum
Average
Working
Weight
Pressure with flange
[bar]
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
CL150
[kg]
31.7
32.0
33.0
37.0
41.2
49.9
35.8
36.0
37.0
41.4
45.9
54.8
51.9
52.0
53.0
58.2
63.4
73.7
59.3
59.3
60.5
66.5
72.6
84.5
63.2
63.4
64.4
70.8
77.1
89.8
66.9
67.2
68.1
74.9
81.6
94.9
78.3
78.6
79.6
87.0
94.4
109.2
92.3
92.6
93.7
103.0
Note: Other sizes, or multiple size branched tees available on request. Please contact Ameron.
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 16 of 28. Printed in The Netherlands.
Bushing Saddles
Filament-wound pipe saddles with stainless steel, 1/2 inch and 3/4 inch
threaded bushings.*
Nominal
Pipe
Size
[mm] [inch]
50
2
80
3
100
4
125
5
150
6
200
8
250
10
300
12
350
14
400
16
450
18
500
20
600
24
Angle
α
[degree]
180
180
180
180
180
180
180
180
180
180
90
90
90
Saddle
Length
(B)
[mm]
100
100
100
100
100
100
100
100
100
100
100
100
100
Saddle Maximum
Thickn. Working
(ts) Pressure
[mm]
[bar]
14
16
14
16
14
16
14
16
14
16
14
16
14
16
14
12
14
12
14
12
14
12
14
12
14
12
Average
Weight
[kg]
0.5
0.6
0.8
0.9
1.0
1.2
1.6
1.9
2.1
2.5
3.3
3.7
4.4
Required
Adhesive
Kits
[3 Oz] [6 Oz]
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
2
* Consult Ameron for other type material, or other sized bushings.
45º Laterals
Filament-wound 45° laterals with integral Quick-Lock socking ends.
Nominal
Pipe
Size
[mm] [inch]
50
2
80
3
100
4
125
5
150
6
200
8
250
10
300
12
350
14
400
16
Laying
Length
(LL1)
[mm]
64
76
76
89
89
114
127
140
140
140
Overall
Length
(OL1)
[mm]
110
122
122
146
146
178
197
216
229
242
Laying
Length
(LL2)
[mm]
203
254
305
337
368
445
521
622
622
622
Overall
Length
(OL2)
[mm]
249
300
351
394
425
509
591
698
711
724
Maximum
Working
Pressure
[bar]
16
16
16
16
16
16
12
12
12
12
Average
Weight
[kg]
1.6
3.0
3.9
5.8
6.8
12.0
21.0
30.0
39.0
54.0
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 17 of 28. Printed in The Netherlands.
Concentric Reducers
Filament-wound concentric reducers with integral Quick-Lock (1-16 inch) or
Taper/Taper (18-40 inch) socket ends.
Nominal
Pipe Size
(runxrun)
Quick-Lock
Taper/Taper
[mm]
40x25
50x25
50x40
80x40
80x50
100x50
100x80
125x80
125x100
150x80
150x100
150x125
200x100
200x125
200x150
250x150
250x200
300x200
300x250
350x250
350x300
400x300
400x350
450x400
500x400
500x450
600x400
600x450
600x500
700x400
700x450
700x500
700x600
750x400
750x450
750x500
750x600
750x700
800x400
800x450
800x500
800x600
800x700
800x750
900x500
900x600
900x700
900x750
1000x900
[inch]
1½x1
2x1
2x1½
3x1½
3x2
4x2
4x3
5x3
5x4
6x3
6x4
6x5
8x4
8x5
8x6
10x6
10x8
12x8
12x10
14x10
14x12
16x12
16x14
18x16
20x16
20x18
24x16
24x18
24x20
28x16
28x18
28x20
28x24
30x16
30x18
30x20
30x24
30x28
32x16
32x18
32x20
32x24
32x28
32x30
36x20
36x24
36x28
36x30
40x36
Laying
Length
(LL)
[mm]
32
64
32
76
54
76
73
74
74
97
94
110
138
126
98
117
105
149
137
184
178
165
152
103
225
123
453
353
230
765
661
542
311
876
775
653
422
111
1023
920
798
570
259
148
1029
799
487
375
285
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 18 of 28. Printed in The Netherlands.
Overall
Length
(OL)
[mm]
91
137
110
154
146
168
165
177
177
200
197
224
248
247
219
244
239
289
283
343
343
343
343
319
454
364
733
645
535
1045
953
847
667
1156
1067
958
778
467
1303
1212
1103
926
615
504
1359
1180
868
756
898
Maximum
Working
Pressure
[bar]
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
Average
Weight
[kg]
0.2
0.3
0.5
0.5
0.5
1.1
0.9
1.4
1.5
1.8
1.8
1.8
2.9
2.8
2.7
3.7
3.6
5.0
4.6
7.2
7.3
8.9
9.0
12.7
22.6
18.9
48.4
44.3
38.5
79.0
74.0
69.0
67.3
111.6
106.6
99.6
87.2
57.2
139.4
125.4
108.8
94.3
81.8
70.9
210.0
176.1
140.2
125.9
182.0
Eccentric Reducers
Filament-wound Eccentric Reducers with integral Quick-Lock (1-16 inch) or
Taper/Taper (18-40 inch) socket ends.
Nominal
Pipe Size
(runxrun)
Quick-Lock
Taper/Taper
[mm]
40x25
50x25
50x40
80x40
80x50
100x50
100x80
125x100
150x80
150x100
150x125
200x100
200x150
250x150
250x200
300x200
300x250
350x250
350x300
400x300
400x350
450x300
450x350
450x400
500x400
500x450
600x400
600x450
600x500
750x400
900x400
Laying
Length
[inch]
1½x1
2x1
2x1½
3x1½
3x2
4x2
4x3
5x4
6x3
6x4
6x5
8x4
8x6
10x6
10x8
12x8
12x10
14x10
14x12
16x12
16x14
18x12
18x14
18x16
20x16
20x18
24x16
24x18
24x20
30x24
36x24
(LL)
[mm]
56
100
44
150
108
200
93
101
293
200
100
390
190
392
202
390
190
308
118
306
188
450
322
197
324
197
580
450
325
451
832
Overall Eccentricity
Length
(OL)
[mm]
115
173
122
228
200
292
185
204
396
303
214
500
311
519
336
530
336
467
283
484
379
640
525
413
553
438
860
742
630
807
1213
(X)
[mm]
7
13
6
20
14
27
12
14
39
27
13
52
25
53
27
53
26
42
16
41
25
63
43
18
39
22
93
73
48
86
161
Maximum
Working
Pressure
[bar]
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
Average
Weight
[kg]
0.2
0.3
0.5
0.5
0.5
1.1
0.9
1.5
1.8
1.8
1.8
2.9
2.7
3.7
3.6
5.0
4.6
7.2
7.3
8.9
9.0
15.6
14.2
12.7
23.0
18.9
48.0
44.0
39.0
87.0
176.0
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 19 of 28. Printed in The Netherlands.
Heavy-Duty Flanges
Filament-wound Heavy-Duty flanges with integral Quick-Lock (1-40 inch) socket end.
Nominal
Pipe
Size
[mm] [inch]
25
1
40
1½
50
2
80
3
100
4
125
5
150
6
200
8
250
10
300
12
350
14
400
16
450
18
500
20
600
24
700
28
750
30
800
32
900
36
1000
40
Laying
Length
(LL)
[mm]
3
3
4
5
5
5
6
6
6
5
8
8
10
10
11
14
14
14
14
15
Overall Maximum
Length Working
(OL) Pressure
[mm]
29
35
51
51
51
62
63
70
76
81
97
110
114
121
138
165
178
192
178
245
[bar]
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
Average weight DIN 2632DIN 2633
ANSI
ANSI
B16.5
B16.5
CL.150
CL.300
PN10
PN16
[kg]
[kg]
[kg]
[kg]
0.5
0.6
0.5
0.5
1.1
1.1
1.0
1.0
1.3
1.7
1.8
1.8
1.8
2.6
2.4
2.4
2.8
3.8
2.7
2.7
3.8
5.4
4.0
4.0
4.5
6.7
4.9
4.9
5.0
9.9
7.1
6.9
9.5
13.2
9.1
9.8
14.5
19.2
11.2
12.7
20.5
29.8
18.6
20.5
27.0
40.0
25.0
27.4
32.0
40.0
58.0
73.0
88.0
112.0
116.0
162.0
-
Note: Other drillings may be possible. Please consult Ameron.
1)
2)
3)
Hub Flanges
Full-face elastomeric gaskets may be used suitable for the service pressure, service
temperature and fluid. Shore A durometer hardness of 60 +5 is recommended (3 mm thick).
Compressed fibre gaskets (3 mm thick), compatible with pressure, temperature and medium
may also be used.
Mechanical properties should be in accordance with DIN 3754 (IT 400) or equal.
For maximum bolt torque refer to the appropriate Bondstrand literature.
A torque-wrench must be used, since excessive torque may result in flange damage.
Size 18-40 inch can be bonded directly to a fitting by using a Quick-Lock to Taper/Taper
transition nipple. For bonding to pipe, a Quick Lock (straight) spigot has to be shaved on
the pipe.
Filament-wound Hubbed flanges with integral Quick-Lock (1-36 inch) socket end.
Nominal
DIN 2633
Pipe
Size
[mm] [inch]
50
2
80
3
100
4
125
5
150
6
200
8
250
10
300
12
350
14
400
16
450
18
500
20
600
24
700
28
750
30
800
32
900
36
Laying
Overall
Length
Length Thickness
(LL)
[mm]
4
5
5
5
6
6
6
5
8
8
10
10
11
14
14
14
14
(OL)
[mm]
51
51
51
62
63
70
76
81
97
110
114
121
138
165
178
192
178
Flange
(E)
[mm]
30
30
33
47
47
54
54
56
72
85
89
96
113
114
121
124
140
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 20 of 28. Printed in The Netherlands.
Maximum
Working
Pressure
[bar]
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
Average weight
ANSI
B16.5
CL.150
[kg]
0.9
1.5
2.2
3.7
3.7
6.2
8.4
12.3
17.3
26.0
30.0
35.0
48.0
67.0
77.0
85.0
93.0
ANSI
B16.5
CL.300
[kg]
1.1
1.8
2.9
4.9
5.4
8.4
11.1
15.3
22.6
32.9
-
DIN 2632
PN10
[kg]
1.0
1.6
2.1
3.6
3.9
6.0
7.6
9.0
14.1
20.6
-
PN16
[kg]
1.0
1.1
2.1
3.6
3.9
6.0
8.2
10.2
15.5
22.6
-
Stub-end Flanges
Quick-Lock
Taper/Taper
Filament-wound O-ring sealed stub-end flanges with integral Quick-Lock (1-16 inch) or
Taper/Taper (18-40 inch) socket ends with loose steelrings.
Nominal
Pipe
Size
[mm] [inch]
25
1
40
1½
50
2
80
3
100
4
125
5
150
6
200
8
250
10
300
12
350
14
400
16
450
18
500
20
600
24
700
28
750
30
800
32
900
36
1000
40
Laying
Length
(LL)
[mm]
10
10
10
10
10
10
10
10
10
10
10
10
20
20
20
20
20
20
20
20
Overall
Length
(OL)
[mm]
37
42
56
56
56
67
67
74
80
86
98
112
134
147
198
198
198
198
223
430
Face
Diameter
(RF)
[mm]
51
73
92
127
157
186
216
270
324
378
413
470
532
580
674
800
850
900
1000
1100
Ring
to Face
(H)
[mm]
10
10
10
10
16
16
16
16
23
23
27
27
35
39
47
51
46
48
53
58
Maximum Average
Working
Weight
Pressure Stub-end
[bar]
[kg]
16
0.1
16
0.2
16
0.2
16
0.4
16
0.6
16
1.0
16
1.2
16
1.8
16
2.5
16
3.3
16
3.8
16
5.7
16
11.1
16
13.2
16
17.2
16
21.0
16
24.4
16
21.8
16
30.8
16
470
Note: Up to 12 bar flat faced stub-ends suitable for elastomeric gaskets can be used.
From 12 bar and above O-ring sealed stub-ends should be used.
Make sure that when using O-ring sealed stub-end, its counter flange is compatible, e.g. use a flat
faced stub-end (without O-ring groove) or another flat surface flange as counter flange.
Steel Ring Flange for
Stub-end
Nominal
ANSI Average
ANSI Average DIN 2632 Average DIN 2633 Average
Pipe
B16.5 Weight
B16.5 Weight
Weight
Weight
Size
CLASS.150
CLASS.300
PN 10
PN 16
(D)
(D)
(D)
(D)
[mm] [inch]
[mm]
[kg]
[mm]
[kg]
[mm]
[kg]
[mm]
[kg]
25
1
14.3
0.8
17.5
1.3
16
1.0
16
1.0
40
1½
17.5
1.2
20.6
2.3
16
1.7
16
1.7
50
2
19.0
1.8
22.2
2.5
18
2.2
18
2.2
80
3
23.8
3.2
28.6
4.8
20
3.0
20
3.0
100
4
23.8
4.2
31.7
7.0
20
3.1
20
3.1
125
5
23.8
4.4
34.9
9.5
22
3.6
23
3.8
150
6
25.5
5.2
36.5
12.2
22
4.9
23
5.1
200
8
28.8
8.5
41.3
18.3
25
7.1
27
7.3
250
10
35.6
13.5
47.6
26.0
28
9.3
32
11.8
300
12
40.0
23.0
50.8
38.7
29
10.7
35
15.4
350
14
41.6
32.0
54.0
56.3
36
21.3
40
26.3
400
16
47.9
42.0
58.2
70.1
40
26.6
44
33.0
450
18
50.2
39.7
63.6
86.5
42
27.2
50
40.9
500
20
52.0
50.6
66.5
104.1
45
34.7
54
59.8
600
24
63.7
86.1
78.4
182.9
52
55.3
63
72.2
700
28
69.0
100.5
95.6
213.4
57
78.8
59 101.9
750
30
71.6
117.0
99.9
229.3
800
32
76.9
153.5
106.2
289.0
62
95.3
66 105.7
900
36
85.4
197.2
117.7
424.1
66
111.8
71 125.1
1000 40
93.7
102.8
74
82
Note: Other materials and/or drillings are available. Please consult Ameron.
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 21 of 28. Printed in The Netherlands.
Blind Flanges
Filament-wound blind flanges.
Nominal
Pipe
Size
[mm] [inch]
25
1
40
1½
50
2
80
3
100
4
125
5
150
6
200
8
250
10
300
12
350
14
400
16
450
18
500
20
600
24
700
28
750
30
800
32
900
36
Flange
Thickness
(D)
[mm]
25
25
30
30
35
35
40
45
50
60
65
70
70
70
85
85
90
95
100
Maximum
Average weight
Working ANSI B16.5 ANSI B16.5
Pressure CLASS 150 CLASS 300
[bar]
[kg]
[kg]
16
0.4
0.5
16
0.5
0.9
16
0.7
1.2
16
1.1
1.9
16
1.7
3.6
16
2.6
3.8
16
2.9
5.7
16
5.2
9.2
16
7.2
13.8
16
11.4
23.0
16
16.4
31.0
16
23.0
41.0
16
43.0
52.0
16
52.0
63.0
16
85.0
106.0
16
110.0
136.0
16
132.0
160.0
16
145.0
184.0
16
206.0
239.0
Average weight
DIN 2632 DIN 2633
PN 10
PN 16
[kg]
[kg]
0.4
0.5
0.7
0.8
1.1
1.2
1.6
1.7
2.6
2.7
3.0
3.1
4.4
4.6
7.1
7.3
10.6
11.5
16.3
17.8
23.0
25.0
31.0
33.0
40.0
43.0
48.0
54.0
79.0
91.0
104.0
106.0
129.0
116.0
155.0
125.0
191.0
192.0
Note: Other drillings are available. Please consult Ameron.
Couplings
Quick-Lock
Taper/Taper
Filament-wound couplings with integral Quick-Lock (1-16 inch) or
Taper/Taper (18-40 inch) socket ends.
Nominal
Pipe
Size
[mm]
[inch]
25
1
40
1½
50
2
80
3
100
4
125
5
150
6
200
8
250
10
300
12
350
14
400
16
450
18
500
20
600
24
700
28
750
30
800
32
900
36
1000
40
Laying
Length
(LL)
[mm]
10
10
10
10
10
10
10
10
10
10
19
19
70
70
70
70
70
70
70
70
Overall
Length
(OL)
[mm]
64
74
102
102
102
124
124
138
150
162
197
223
298
324
426
426
426
426
476
890
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 22 of 28. Printed in The Netherlands.
Outside
Diameter
(OD)
[mm]
42
58
72
100
129
153
183
235
289
340
372
422
460
514
619
742
795
848
950
1057
Maximum
Working
Pressure
[bar]
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
Average
Weight
[kg]
0.1
0.1
0.3
0.4
0.6
0.9
1.1
1.7
2.3
2.8
4.6
7.2
10.7
13.0
18.8
23.5
24.5
27.0
34.5
40.7
Nipples
Filament-wound nipples with integral Quick-Lock (1-16 inch) or
Taper/Taper (18-40 inch) male ends.
Quick-Lock
Nominal
Pipe
Size
[mm]
25
40
50
80
100
125
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
Taper/Taper
[inch]
1
1½
2
3
4
5
6
8
10
12
14
16
18
20
24
28
30
32
36
40
Laying
Length
(LL)
[mm]
57
67
95
95
95
117
118
130
143
156
184
210
278
304
406
406
406
406
456
870
Gap*
[mm]
3
3
3
3
3
3
3
3
3
3
3
3
50
50
50
50
50
50
50
50
Maximum
Working
Pressure
[bar]
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
Average
Weight
[kg]
0.1
0.1
0.1
0.1
0.2
0.3
0.4
0.6
0.9
1.1
3.1
4.4
5.9
7.8
12.0
21.0
22.0
24.0
36.0
51.0
* Remaining gap after bonding.
Transition Nipples
Filament-wound transition nippels with integral Taper/Taper (18-40 inch) male ends.
Nominal
Pipe
Size
[mm]
450
500
600
700
750
800
900
1000
[inch]
18
20
24
28
30
32
36
40
Laying
Length
(LL)
[mm]
238
263
338
374
386
400
410
685
Gap*
[mm]
19
25
33
44
44
44
43
45
Maximum
Working
Pressure
[bar]
16
16
16
16
16
16
16
16
Average
Weight
[kg]
6
7
9
15
22
30
40
45
* Remaining gap after bonding.
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 23 of 28. Printed in The Netherlands.
Support Saddles
α
α
Filament-wound pipe saddles for wear, support and anchor.
Nominal
Pipe
Size
[mm]
[inch]
25
1
40
1½
50
2
80
3
100
4
125
5
150
6
200
8
250
10
300
12
350
14
400
16
450
18
500
20
600
24
700
28
750
30
800
32
900
36
1000
40
Saddle
Angle
α
[degree]
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
180
Saddle
Saddle
Thickn.
Weight
ts B=100mm
[mm]
[kg]
14
0.2
14
0.3
14
0.4
14
0.5
14
0.7
14
0.8
14
0.9
14
1.1
14
1.5
14
1.8
14
2.0
14
2.4
16
16
16
16
16
16
16
16
-
Required
Saddle
Adhesive
Weight
Kits
B=150mm
[3 and 6Oz]
[kg]
1
0.3
1
0.5
1
0.6
1
0.8
1
1.1
1
1.2
1
1.4
1
1.7
1
1
2.3
1
1
2.7
1
1
3.0
2
3.6
3.2
3.6
4.3
5.1
5.5
5.8
6.5
8.2
Required
Adhesive
Kits
[3 and 6 Oz]
1
1
1
1
1
1
1
1
1
1
2
1
2
1
2
3
2
2
2
3
3
3
4
4
Notes:
1) Filament-wound support saddles are intended for protection of pipe at supports and clamps,
as well as for anchoring purposes. Support and anchor saddles are standard 180°.
Saddles are supplied in standard lengths of 100 mm and 150 mm.
2) For special saddle -lengths, -thickness and/or angles consult Ameron.
3) Wear saddles are standard 90°. Weights of 90° degree saddles are 50% of value shown.
Grounding Saddles
Filament-wound pipe saddles for grounding in conductive piping systems.
Nominal
Pipe
Size
[mm]
[inch]
25
1
40
1½
50
2
80
3
100
4
125
5
150
6
200
8
250
10
300
12
350
14
400
16
450
18
500
20
600
24
700
28
750
30
800
32
900
36
1000
40
Saddle
Angle
α
[degree]
90
90
90
90
90
90
90
45
45
45
45
45
221/2
221/2
221/2
221/2
221/2
221/2
221/2
221/2
Saddle
Length
B
[mm]
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
76
Saddle
Thickness
ts
[mm]
14
14
14
14
14
14
14
14
14
14
14
14
16
16
16
16
16
16
16
16
Average
Saddle
Weight
[kg]
0.1
0.1
0.1
0.1
0.2
0.3
0.3
0.2
0.2
0.2
0.3
0.3
0.2
0.2
0.3
0.3
0.4
0.4
0.4
0.5
Notes:
1) Bondstrand conductive adhesive should be used for mounting.
2) Saddles are supplied with integrated stainless steel cable with a length of 600 mm.
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 24 of 28. Printed in The Netherlands.
Required
Adhesive
Kits
[3Oz]
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
3
3
3
Bell Mouths
Filament-wound bell mouths with adhesive-bonded HD-flange.
Nominal
Pipe
Size
[mm]
[inch]
50
2
80
3
100
4
125
5
150
6
200
8
250
10
300
12
350
14
400
16
450
18
500
20
600
24
Overall
Length
(OL)
[mm]
269
274
289
323
324
533
594
569
605
588
627
724
831
Length of
Bell Mouth
(H1)
115
120
135
158
158
340
395
365
375
345
360
450
540
Internal
Diameter
(D1)
[mm]
110
220
275
400
450
750
850
850
850
850
900
1100
1300
Internal
Diameter
(D2)
[mm]
110
220
275
400
450
418
518
510
510
510
548
548
648
Average
Weight*
[kg]
3.1
5.0
8.4
12.7
14.7
26.0
39.0
51.0
60.0
67.0
90.0
119.0
171.0
* Weights provided are for bell mouth with CL150 flange.
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 25 of 28. Printed in The Netherlands.
Assembly of double
O-ring expansion joint
Expansion Coupling
Filament-wound Key-Lock expansion coupling with integral double O-ring Key-Lock
female end one side and double O-ring female end on other side.
Nominal
Pipe
Size
[mm]
[inch]
50
2
80
3
100
4
125
5
150
6
200
8
250
10
300
12
350
14
400
16
450
18
500
20
600
24
700
28
Laying
Length
(LL)
[mm]
50
50
50
50
50
50
50
50
50
50
50
50
50
50
Overall
Length
(OL)
[mm]
222
222
222
264
270
337
356
410
430
450
416
433
479
560
O-ring
Size
Key
Size
Average
Weight
[mm]
7 x 59.7
7 x 88.3
7 x 113.7
9 x 135
10 x 161.3
10 x 225.5
12.5 x 302
12.5 x 342.3
12.5 x 342.3
12.5 x 393.1
15.0 x 445.0
15.0 x 490.0
18.0 x 580.0
20.0 x 685.0
[mm]
6 x 305
6 x 400
6 x 483
8 x 580
8 x 660
10 x 840
12 x 1270
15 x 1270
15 x 1360
18 x 1585
15x1750
15x1930
18x2240
20x2700
[kg]
1.3
1.7
3.5
4.6
6.6
15.4
19.9
21.0
25.0
32.0
27.0
32.0
52.0
99
Key-Lock Adapter for
Expansion Coupling
Filament-wound double O-ring male Key-Lock adapter with integral Quick-Lock
(2-16 inch) or Taper/Taper (18-40 inch) socket end.
Quick-Lock
Nominal
Pipe
Size
[mm]
50
80
100
125
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
Taper/Taper
[inch]
2
3
4
5
6
8
10
12
14
16
18
20
24
28
30
32
36
40
Laying
Length
(LL)
[mm]
85
85
85
102
105
138
148
175
185
195
193
201
224
265
272
307
362
355
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 26 of 28. Printed in The Netherlands.
Overal
Length
(OL)
[mm]
131
131
131
159
162
202
218
251
274
297
307
328
402
443
450
485
465
765
Pressure
Weight
[bar]
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
[kg]
0.4
0.6
0.9
1.6
1.8
5.1
11.8
14.6
10.7
15.9
19.5
23.5
25.0
29.0
34.0
42.0
50.0
64.0
Double O-ring Adapter
for Expansion Coupling
Filament-wound double O-ring male adapter with integral Quick-Lock (1-16 inch) or
Taper/Taper (18-40 inch) socket end.
Quick-Lock
Nominal
Pipe
Size
[mm]
50
80
100
125
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
Taper/Taper
Adhesive
[inch]
2
3
4
5
6
8
10
12
14
16
18
20
24
28
30
32
36
40
Laying
Length
(LL)
[mm]
85
85
85
102
105
138
148
175
185
195
193
201
224
265
272
307
362
355
Overall
Length
(OL)
[mm]
131
131
131
159
162
202
218
251
274
297
307
328
402
443
450
485
465
765
Average
Weight
[cm3]
88.7
88.7
88.7
88.7
88.7
88.7
88.7
88.7
177.4
177.4
177.4
177.4
177.4
177.4
177.4
177.4
177.4
177.4
177.4
177.4
Required
Adhesive Kit
Size
[Oz]
3
3
3
3
3
3
3
3
6
6
6
6
6
6
6
6
6
6
6
6
Minimum number
of Adhesive Kits
required per joint
nr.
1/5
1/5
1/4
1/3
1/2
1
1
1
1
1
2
2
2
3
4
4
5
5
6
6
[kg]
0.4
0.7
0.9
1.6
1.8
5.1
11.8
14.6
10.7
15.9
19.5
23.5
25.0
29.0
34.0
42.0
50.0
64.0
Number of Adhesive Kits per joint.
Nominal
Pipe
Size
[mm]
25
40
50
80
100
125
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
[inch]
1
1½
2
3
4
5
6
8
10
12
14
16
18
20
24
28
30
32
36
40
Notes:
1) Adhesive Kits should never be split. If remainder is not used for other joints made at the same
time, the surplus must be discarded.
2) Required adhesive for saddles is shown in the dimension table of the respective saddles.
3) For type of adhesive to be used, please refer to the Bondstrand® Corrosion Guide.
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 27 of 28. Printed in The Netherlands.
Engineering design &
installation
Consult de following literature for recommendations pertaining design, installation and
use of Bondstrand pipe, fittings and flanges:
Assembly Instructions for Quick-Lock adhesive-bonded joints
Assembly Instructions for Taper/Taper adhesive-bonded joints
Assembly Instructions for Bondstrand fiberglass flanges
Bondstrand Corrosion Guide for fiberglass pipe and tubing
Bondstrand Pipe Shaver Overview
Bondstrand Marine Design Manual
FP 170
FP 564
FP 196
FP 132
FP 599
FP 707
Please consult Ameron for the latest version of the above mentioned literature.
Specials
Note: Elbows with non-standard angles, non-standard drilled flanges, multi branch tees
and special spools are available on request, please consult Ameron.
Field testing
Pipe system is designed for hydrostatic testing with water at 150% of rated pressure.
Surge pressure
Maximum allowable surge pressure is max. 150% of rated pressure.
Conversions
1 psi
1 bar
1 MPa
1 inch
1 Btu.in/ft2h°F
°C
Important notice
This product literature and the recommendations for usage it contains are based on test data
reasonably believed to be reliable. It is intended that this literature be used by personnel
having specialised training in accordance with currently acceptable industry practice and
normal operating conditions. Variation in environment, changes in operating procedures, or
extrapolation of data may cause unsatisfactory results. We recommend that your engineers
verify the suitability of this product for your intended application. Since we have no control
over the conditions of service, we expressly disclaim responsibility for the results obtained
or for any consequential or incidental damages of any kind incurred.
= 6895 Pa
= 105Pa
= 1 N/mm2
= 0.07031 kg/cm2
= 14.5 psi
= 1.02 kg/cm2
= 145 psi
= 10.2 kg/cm2
= 25.4 mm
= 0.1442 W/mK
= 5/9 (°F-32)
Group Headquarters
Ameron International Corporation - Fiberglass-Composite Pipe Division
9720 Cypresswood Drive, Suite 325 - Houston, Texas 77070 - U.S.A.
Phone: +1 832 912 8282 - Fax: +1 832 912 9393
E-mail: marcom@ameronfpd.com
Website: http://www.ameron-fpg.com
U.S.A.
Ameron International Corporation
1004 Ameron Road
P.O. Box 878
Burkburnett, Texas 76364
U.S.A.
Phone: +1 940 569 1471
Fax: +1 940 569 2764
U.S.A.
Centron International, Inc.
P.O. Box 490
600 FM 1195 South
Mineral Wells - Texas 76068
U.S.A.
Phone: +1 940 325 1341
Fax: +1 940 325 9681
E-mail: info@centrongre.com
Europe
Ameron B.V.
Fiberglass-Composite Pipe
P.O. Box 6
4190 CA Geldermalsen
The Netherlands
Phone: +31 345 587 587
Fax: +31 345 587 561
E-mail: info@ameron-fpg.nl
© Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 28 of 28. Printed in The Netherlands.
Asia
Ameron (Pte) Ltd.
No. 7A, Tuas Avenue 3
Jurong
Singapore 639407
Phone: +65 6861 6118
Fax: +65 6862 1302/6861 7834
E-mail: info@ameron.com.sg

Similar documents

Retails Region Light Beam Angles

Retails Region Light Beam Angles Administrative buildings, living places, shopping centres or factories, all convert electrical energy to light systems, and when illuminated brings with it a variety of security issues. Founded in ...

More information