FluorPen Features FluorPen Applications

Transcription

FluorPen Features FluorPen Applications
Z990 FluorPen
Handheld Chlorophyll Fluorometer for Rapid Plant Screening
Measure Ft, Fv/Fm, and Chlorophyll Fluorescence Kinetics
Z990 FluorPen is a pulse-modulated, hand-held chlorophyll fluorometer for rapid plant screening in the laboratory, growth room and field. The FluorPen replaces
bulky and expensive fibre-optic instruments for measuring chlorophyll fluorescence parameters. It uses high
output LEDs to provide a saturating pulse for measurements of Fv/Fm (QY) and other parameters. Standard
model measures Ft and Fv/Fm. The more sophisticated
model also measures OJIP, NPQ and Light Curve kinetics. The Z995 FluorPen PAR in addition to all parame- • Lightweight, hand-held design
ters mentioned above also measures photosynthetically
• Easy two-buttons operation
active radiation (PAR) in the range of 400 to 700 nm.
• Battery-operated (4 x AAA)
FluorPen Features
FluorPen Applications
• Measurements of Ft, QY (standard)
• Rapid plant screening
• Kinetic measurements (OJIP, NPQ, LC) (optional)
• Herbicide effects
• FluorPen software (optional)
• Photosynthesis research
• BT or USB data transfer (optional)
• Plant Stress screening
• Built in PAR meter (optional)
• Agronomy (nutrient use)
• GPS mapping (optional)
1573 John Counter Blvd., Kingston,
Ontario, Canada K7M 3L5
www.qubitbiology.com
info@qubitsystems.com
World Wide 01.613.384.1977
North America 888.262.2219
• Leaf clips for dark adaptation (optional)
FluorPen
Technical Specifications
•
Measured Parameters: Fo, Ft, Fm, QY (standard),
•
Battery Life: 48 hr typical with full operation
kinetics (OJIP, NPQ, LC) (optional)
•
Low Battery detection
•
Actinic Light: Adjustable 0-1000 µmol/m2/s
•
Size: 120 x 57 x 30mm
•
Saturating Light: Adjustable from 0-3000 µmol/m2/s
•
Weight: 180g
•
Detector Range: PIN photodiode with 697-750nm
•
Sample Holder: mechanical leaf clip (standard),
•
FluorPen Software: Windows XP or higher (optional)
•
Communication via BT or USB (optional)
•
PAR meter in 400-700nm range (optional)
Temperature: 0 to55°C
•
GPS module (optional)
RH: 0 to 95% (non-condensing)
•
Memory: 4Mb (100,000 data points)
•
Display: 2 x 8 characters LCD
Temperature: -10 to 60°C
•
Keypad: sealed, 2-key tactile response
RH: 0 to 95% (non-condensing)
•
Keypad Escape Time: after 5 min of no use
•
Power Supply: 4 x AAA alkaline or rechargeable batteries
dark adaptation removable leaf clips(optional)
•
•
•
Operating Conditions:
Storage Conditions:
Warranty: 1 yr parts and labor
1573 John Counter Blvd., Kingston, Ontario, Canada K7M 3L5
www.qubitbiology.com / info@qubitsystems.com
World Wide 01.613.384.1977
North America 888.262.2219