Immergas SE External Flyer Brochures
Transcription
Immergas SE External Flyer Brochures
IMMERGAS SE EXTERNAL BOILER Wall hung traditional hydronic system boiler for outdoor installation MANUFACTURED BY: •S ealed room fan assisted model with a 36 kW heat output • Compact dimensions • Automatic system by-pass • D.H.W. Storage Tank (optional) •E lectronic control board microprocessor driven • Electronic ignition and full modulation • Diagnostic and performance display • Intelligent External Controller CARV2 with outside sensor (optional) 2 YEAR* CARV2 WARRANTY EXTERNAL SENSOR MAIN OPTIONS MEASUREMENTS CARV2 - 3.021395 External Sensor - 3.014083 Anti-freeze protection (-15oC) - 3.017324. 1000 x 555 x 255 (H x W x D) mm Empty appliance weight - 45 kg. MAIN FLUE KITS Vertical concentric kit 60/100 - 3.023758. SHOWROOM 11 Fiveways Boulevard Keysborough VIC 3173 PHONE 1300 00 1800 FAX (+613) 9798 5133 HUNT HEATING The smart choice. enquiries@huntheat.com.au www.huntheat.com.au IMMERGAS SE EXTERNAL BOILER Outputs & Dimensions Model Code NG./LPG Heat output kW Efficiency at nom. heat output Protection index SE 32 kW IMG SE 32+ E NG IMG SE 32+ E LPG 36 87.3% IPX5D COMBUSTION PARAMETERS Supply Pressure Flue temperature at nominal output NG (G20) LPG (G30) kPa 1.0 2.8 C 67 68 o TECHNICAL DATA Heat output NG mJ/h (kW) 128.5 (35.7) Heat output LPG mJ/h (kW) 128.5 (35.7) Burner pressure maximum NG/LPG kPa 0.70 / 2.10 Burner pressure minimum NG/LPG kPa 0.19 / 0.55 % 87.30 Efficiency 50/30 Nom./Min. % 93.20 Adjustable central heating temperature o Efficiency 80/60 Nom./Min. C 35 - 85 bar 1 bar (psi) 3 (44) L 10 kPa (m H2O) 30.2 (3.1) V/Hz 230 / 50 W 180 Expansion vessel factory-set pressure Pressure relief setting Expansion vessel capacity Head available with 1000 l/h flow rate Electrical connection Installed electric power F R 165 F R 95 C F 165 95 F C Key: G - Gas supply (not supplied as standard) Key: R G- - Return - CH Gas supply (not supplied as standard) F R- - Flow - CH Return - CH Flow -fill CH C F- - Cold F R 165 C - Cold fill 95 C F Key: G R F C - Height Height (mm) Gas supply (not supplied as standard) (mm) 1000 Return - CH 1000 Flow - CH Cold fill CORD INLET CORD INLET C C1/2” 1/2” IMG.V038.02.15.HH Height (mm) 1000 Width (mm) Depth (mm) 555 255 CONNECTIONS CORD INLET GAS C G * Please contact Hunt Heating for terms and conditions SYSTEM R F Width Width (mm) (mm) DepthDepth (mm)(mm) 555 255 555 CONNECTIONS 255 CONNECTIONS GAS SYSTEM GAS G 3/4” G 3/4” SYSTEM F R 3/4” R 3/4” 3/4” F 3/4”
Similar documents
Immergas Partage Boxes
DIMV2 TOP H-LT Hydraulic manifold, 2 low consumption pumps, 1 mixing valve and electronic board DIMV2 TOPH-2LT Hydraulic manifold, 3 low consumption pumps, 2 mixing valves and electronic board
More informationCatalogue 03/2016
services and generate domestic hot water. Remember that to obtain a good winter efficiency with the integration of heating by solar thermal systems, is necessary: • Heating elements that work at l...
More information