information on Biffi Icon multi turn here
Transcription
information on Biffi Icon multi turn here
2000 t uc re od hu Pr roc B ICON2000 Release 2004: share your valve process information! In the communication era, Biffi Italia has engineered new advanced solutions to easily communicate with on-field users and control rooms and to download all the process information and diagnostic data Features More than half a century ago Biffi started its business in valve actuation. Its world-wide leadership has been built through continuous innovation and the ability to face the new challenges that a fast changing environment comes up with. It was in 1992 that Biffi started its intelligent actuator campaign. Since then Biffi Intelligent actuators have been welcomed by all major companies around the world, in many different applications: platforms, deep tropical forest, Siberian chill and harsh desert environment. With ICON2000, we made a further step forward towards ease of use and maintenance. Release 2004 of ICON2000 introduces a new philosophy in the construction of electric actuators electronic cards: all major optional functions are integrated in the base card, which allows easy plug-in of future upgrades. ❑ Engineered as an improvement and optimization of the performances of the existing ICON2000 and totally interchangeable with Release 2000 ❑ Actuator operation, setting and diagnostics are available via the integral user-friendly push-button panel ❑ BluetoothTM, radiofrequency wireless connector based on a qualified BluetoothTM class 1 module(*) ❑ Watertight and explosion-proof PDAs are available from Biffi Italia for actuator operation, download of diagnostic info, non-intrusive upgrading of firmware and for maintenance purposes through BluetoothTM ❑ Enhanced hardware and software performances to offer: - advanced maintenance data including reports on the last opening and closing position/torque curves with relative parameters and with direct comparisons with torque signature; - detailed and updated information on actuator internal parameters with precise and clear alarm reports, with both General and Recent (partial) log; - “Data logger” function for collecting different types of data for maintenance or diagnostic programs, available both in: • RECORDER mode for measurement and memorization of main actuator internal parameters with configurable SAMPLING TIME and START DATE and TIME • EVENT mode with memorization of OPEN or CLOSE commands, including indication of source, date and time with configurable START DATE and TIME (*) !@#$ flow control 2 US and Italy patented Bluetooth is a trademark of Bluetooth SIG, Inc., USA ❑ Customized displays: - Numeric: 31/2 digits, for the indication of position or torque - Graphic: 32x122 dots, for a complete diagnostic user-friendly communication with the operator - Backlights - Heater - 8 selectable languages as standard ❑ A single enhanced-type terminal board ❑ Advanced open bus communication protocols: - Lonworks - Profibus DPV0, DPV1 and Redundant DPV1 - Foundation Fieldbus - Modbus - Hart Diagnostics Internal circuits continuously monitor the status of the system and elaborate all the information coming from the sensors: diagnostic messages are displayed in one of the available languages, so that there is no need to decipher complicated codes. The set of messages is complete both with alarms and warnings. !@#$ flow control 3 ...in cost reduction and user-friendliness The reduced number of mechanical parts ensures higher reliability and lower maintenance costs. The aluminium alloy highly resistant housing and covers, together with a lower number of joints, have increased Icon capacity to stand up to the most aggressive environments. A double-sealed enclosure assures protection from dust and humidity. The choice of internal components has increased the overall system efficiency (the motor is directly engaged to the gears) lowering the operational costs. Reduction of training costs is also one of the goals we have achieved through the user-friendliness of the system. No more codes to decipher: the Icon menu is clear and easy, and comes with all the following languages: Italian, English, Spanish, Portuguese, French, Turkish, Russian, Norvegian. Internal sensors All internal sensors are contactless. Torque sensor The direct measure of the motor speed reports torque with high precision and a resolution of 1% of the nominal torque. Torque detection is based on motor torque vs. speed characteristics, voltage and temperature compensated. The torque vs. speed curve is memorised for each type of motors and in case of motor replacement simply a new configuration from the actuator local control panel is requested. Position sensor (US Patented) Controlled by a dedicated microprocessor with low power consumption, the contactless position sensor is based on Hall-effect incremental encoder with a resolution of 10° of output shaft rotation. Rotations in both senses are recognised and counted. If manually operated during power failure, the position is updated, stored and displayed locally. Electronic card: the latest technology The card is controlled by a Hitachi high-performance 16-bit microchip, with a 4 Mb flash memory. This allows high flexibility and the possibility to be re-programmed if necessary. The internal wiring is considerably reduced. The modular design of the electronic cards allows high flexibility for a great variety of combinations. !@#$ flow control 4 !@#$ flow control 5 A dedicated software for PC and PDA is available for ICON 2000v4. With the new software, total control of ICON 2000v4 is always available in your hands and in your office. With a smart user-friendly graphic interface, all the actuator information, set-up, configuration data, diagnostic messages and data logger info are available for visualisation, analysis and reconfiguration from your PDA or PC. PDA Manager The PDA Manager will transform your common PDA or dedicated industrial PDA into a strong tool for the complete control, set-up and diagnostics of the ICON 2000v4 actuators installed in your plant. A user-friendly graphic interface reproduces the actuator local control panel for an easy control of the valve and offers several tools for a complete analysis of the actuator status. ICON 2000v4 supports BluetoothTM wireless non-intrusive communication. In particular, with BluetoothTM communication it is possible to communicate with the actuator within a distance of several meters from any angle. In addition, it is possible to connect to all the actuators within operation distance with one single PDA. !@#$ flow control 6 All the data exchanged with the actuator on-field can be shared with your PC in the office through the PC Manager Software. Connect the PDA to the PC with the ActiveSync program and download all the data. Standard PDA minimum basic requirements: ❑ Operating systems: Windows‚ MobileTM 2003 for Pocket PC; ❑ BluetoothTM interface module; ❑ Processor: 266 MHz processor; ❑ Memory: 32 MB SDRAM minimum; ❑ 3.5" TFT display with 16k colour depth. Ex-hazardous area industrial PDA technical characteristics: - High performance industrial PDA based on Windows‚ MobileTM, with compact external dimensions, an integrated WLAN, USB and BluetoothTM port. - Meets different industry requirements operating both inside and outside of Ex-hazardous areas. Basic features: ❑ Ergonomic design to facilitate operations without fatigue during continuous use; ❑ High resolution colour display, readable even in the most unfavourable light conditions; ❑ Protection from static electricity, water and dust; ❑ Shockproof housing (non-corroding); ❑ Standard keyboard with navigation field and programmable keys; ❑ 3.5" TFT display with 16k colour depth. Technical data sheet: ❑ Operating systems: Windows‚ MobileTM 2003 Premium-Software for Pocket PC; ❑ Processor: 400 MHz processor based on Intel technology; ❑ Power supply: Rechargeable battery; ❑ Standard delivery: Unit, Charger, Operating instructions, safety instruction, software CD; ❑ Ex-Data: Ex-hazardous application intrinsically safe type and suitable for different gas and dust atmospheres, ATEX or other certification. !@#$ flow control 7 PC Manager PC Manager transforms your PC into a strong tool for the control, set-up and diagnostics of ICON 2000v4 actuators. A user-friendly graphic interface reproduces the actuator local control panel for an easy control of the valve and offers several tools for a complete analysis of the actuator status. ICON 2000v4 supports BluetoothTM non-intrusive communication or serial communication (intrusive). The same interfaces available with PDA MANAGER with an improved graphic release (considering the larger screens available on PCs) are easily syncronisable with the PDA: - Actuator control: !@#$ flow control 8 - Actuator maintenance and diagnostic informations: - Actuator set-up: - Actuator data logger: PC Manager software supports BluetoothTM, or serial communication (intrusive) with actuator (Windows 2000 and XP operating systems). !@#$ flow control 9 Double sealed terminal box for high protection. Wide enclosure to facilitate wiring connection Easy connection for quick motor removal !@#$ flow control 10 Heavy-duty simplified gearing for higher efficiency High precision internal sensors. Low consumption position encoder specifically designed for electric actuators User friendly interface: actuating your valve has never been so easy Recessed buttons for better protection !@#$ flow control 11 The base version is an intelligent actuator with hardwired (i.e. point-to-point) connection. High profile standards: all major features are included in the base version. Automatic phase correction The valve will be protected as the system automatically recognises and corrects phases preventing any unforeseen error in the rotation direction. Phase failure correction In case of loss of one phase, this features prevents the motor from overheating. The minimum time to set the alarm on is 100 ms, in order to prevent the system from being influenced by casual oscillations. In case of loss of one phase during motor running, the actuator will reach the end-of-travel position before setting the alarm condition and de-energising the actuator. Motor thermostat If during operation the temperature of the motor overrides the security limits, a thermostat will set the alarm condition and the command signal will be inhibited. Jammed valve protection If, after a command (close/open), the valve position does not change within a pre-set time, an alarm condition is set and the command signal will be inhibited. The pre-set time can be any time within an interval of 2 to 100 seconds. Anti-hammer protection This feature will protect both the motor and the valve. If a torque limit is reached it will prevent the valve from moving in the same direction which caused the torque limit. Instantaneous reversal protection When the actuator is operating in one direction and an immediate command for a reverse direction is set, unpredicted current surges arise with possible damages to the motor. To prevent such problems, a delay between the opposite commands can be programmed from 500 ms to 5 seconds. Warnings Warning signals become active when the operating conditions are close to a critical alarm level. Warning is displayed but operation is not interrupted. Remote controls Three different configurations are available: - 4 wires (OP, CL, Stop, C/latched) - 3 wires (OP, CL, C/push-to-run or latched with instant reverse) - 2 wires (NO contact to open or reverse) Control voltage - 24Vdc, internal supply - 20 to 125 Vdc, external supply - 20 to 120 Vac, external supply !@#$ flow control 12 Remote output contacts 7 voltage-free latching relays and one change over single side stable relay are available for remote indication. The latching relay can all be configured as Normally Open or Normally closed contact Closed Each relay can be configured to switch for one condition close in the following list. - Motor over temperature - Fully open - Torque alarm - Fully closed - Torque alarm in opening - Intermediate position - Torque alarm in closing - Position ≥ XX % - Jammed valve alarm - Position ≤ XX % - Jammed valve in opening - Actuator opening - Jammed valve in closing - Actuator closing - Mid-travel alarm - Motor running - Warning - Blinker - Low battery - Local selected - Remote selected - Local stop active - ESD active - Manual operation Emergency shutdown (ESD) When an ESD signal is received (in an emergency situation), the actuator perfoms the ESD programmed action. It can be configured to override any of the following conditions: - Selector in LOCAL - Selector in OFF - Motor temperature alarm - Local STOP pushbutton - Torque alarm - 2 speed timer and it can be programmed to one of the following: - Stay put - Move to open position - Move to close position - Move to pre-set position Interlock controls Two interlock inputs are available to inhibit actuator movement in open or close direction Monitor relay When the actuator is not available for remote control, an alarm condition is set. The contact type is change-over, voltage-free. The monitor relay is normally energized and will be de-energized on: - Loss of power Loss of one phase Electrical contactor failure Internal temperature alarm Position sensor - Speed sensor Configuration error Hardware error Mid-travel alarm The following conditions can be individually configured to switch over the monitor relay: - Loss of one phase Local stop activated Local selector switch in LOCAL/OFF Motor temperature alarm Torque alarm - Jammed valve Manual operation ESD signal Low battery Contactor failure As one of the vital parts of the actuators, contactors are continuously monitored. If a malfunction is detected an alarm is set and the command is inhibited. Maximum torque alarm During torque operation, if the current torque exceeds the relevant set value, the actuator command is inhibited and an alarm condition is set. Opto-coupled remote controls Actuator may be remotely controlled by 4, 3 or 2 wires, depending on the connection on the terminal board. Several options are available: latched, momentary, etc... Torque alarm by-pass During opening command, starting from open/closed position it is possible to set an interval from 0% to 20% of the total stroke where torque alarm is ignored. This will allow the actuator to win the Break-to-open torque. High/Low electronic temperature Through a semiconductor-based temperature sensor, the temperature in the electronic card is detected and an alarm condition is set on reaching the lowest/highest limits. !@#$ flow control 13 Local operator interface The local interface is designed for easy operation and to supply a complete and clear set of information. It is composed of - a padlockable three-position selector for LOCAL/OFF/REMOTE operation selection - three pushbuttons for local OPEN/CLOSE/STOP controls and menu navigation - 2 customised displays, with backlight and heater: • numeric 31/2 digit display for torque and position indication • graphic display supporting various character sets • 3 bi-coloured LED (green/red) to indicate fully open/closed/intermediate position • 1 bicoloured LED (red/yellow) to indicate alarm/warning state. • 1 blue LED to indicate Bluetooth connection active. • Class 2 Bluetooth module available for wireless connection to PDA or PC. All buttons are recessed for protection from accidents or misuse. The local push-buttons OPEN/CLOSE can be configured with 3 options: latched, latched + instant reverse, or push-to-run. Through the local interface the field operator can enter a basic configuration menu which allows to set the following parameters: Base parameters - End of travel position in opening/closing - Opening/closing torque values - Position/torque display - Opening/closing by torque/position - Output contacts - ESD feature - Remote/Local control feature Extended parameters - Timer parameters - Position servo-amplifier parameters - Fieldbus interface parameters - Data logger - Maintenance date - Diagnostic info - PID parameters - …. The configuration menu is password-protected. Three LEDs with settable different colours to indicatevalve opening/closing, alarms, warnings, mid-travel and end-of-the-stroke positions. Added extra features Predictive maintenance Some of the most vital parts of the actuator are monitored: - contactor cycles count - torque trend - alarms data log Timer Function Module (TMR) It allows for partial or complete timer controlled valve stroke.Through the local/remote interface the following can be set: - if it has to be active during opening or closing operation - ON time, from 2 to 200 sec max, with resolution of 1 sec. - OFF time, from 1 to 200 sec max, with resolution of 1 sec. - percentage of position when timer starts in opening - percentage of position when timer starts in closing !@#$ flow control 14 Electronic card identification message Base, terminal board and 4-20mA card are clearly identified with a 64 character message for fast track including: - Biffi assembly code - Assembly serial number - Manufacturing date - Software and Hardware versions - Description Data log ICON2000 is complete with an exhaustive data log system which will allow for storage of main events occurring during actuator operation. The monitored data are: Alarms: ❑ Last 64 alarms and date ❑ Last 64 warnings and date Torque profiles: ❑ Breakout reference torque in opening ❑ Peak running reference torque in opening ❑ Ending reference torque in opening ❑ Breakout torque in opening ❑ Peak running torque in opening ❑ Ending torque in opening ❑ Breakout reference torque in closing ❑ Peak running reference torque in closing ❑ Ending reference torque in closing ❑ Breakout torque in closing ❑ Peak running torque in closing ❑ Ending torque in closing ❑ Date of the last "set torque reference" ❑ Date of last torque profile in opening ❑ Date of last torque profile in closing Torques curves and torque signature: in the memory of ICON 2000 and memorized: ❑ the last 100 torque versus position curves in opening ❑ the last 100 torque versus position curves in opening ❑ the torque signature in opening ❑ the torque signature in closing The above date can be read from Icon2000 to PC or PDA by A-Manager and viewed and compared as graph or excel tables. Operations: ❑ Opening time of the last stroke ❑ Closing time of last stroke ❑ Total contactor operations ❑ Motor run time ❑ Time out without electrical power ❑ Utilisation rate ❑ Torque alarm number ❑ Motor temperature alarm number ❑ Min and Max temperature of motor and electronics ❑ Recent contactor operations ❑ Recent motor run time ❑ Recent time without electrical power ❑ Recent utilisation rate ❑ Recent torque alarm number ❑ Recent motor temperature alarm number ❑ Recent min and max temperature of motor and electronics. Maintenance data: ❑ Last maintenance date ❑ Next maintenance date ❑ Date of the last "clear recent data log" ❑ Start-up date Name plate The basic information about the actuator are electronically stored in a non-volatile memory: ❑ Serial number ❑ Actuator size ❑ Nominal torque ❑ Actuator speed ❑ Power supply ❑ Motor rating ❑ Motor duty ❑ Motor poles ❑ Motor type ❑ Motor current ❑ Test date ❑ Wiring diagram ❑ Enclosure ❑ Certificate ❑ Lubricant ❑ HW version ❑ SW version Valve data To identify the valve and its function in the process, the valve manufacturer/end user can enter the following data: ❑ valve tag name ❑ valve serial number ❑ valve manufacturer ❑ break to open torque ❑ max stem thrust ❑ valve coupling type 28 characters are available for such information. Customisable torque profiles In some applications you need to set different torque profiles for operating the valve. For this reason we have introduced a 3-point torque profile. Sleep mode function (for DC models only) A specific sleep mode function is set up for DC actuators in order to save power available in the plant. All functionalities are kept in stand-by mode when not requested and immediately available on demand. !@#$ flow control 15 The following is a description of our ICON2000 standard features/options and working conditions. For whatever you may require which is not listed below, please contact Biffi Sales offices. Voltage ratings The actuator can accept the following voltage supplies: Three phase: ❑ 50 Hz 230, 240, 380, 400, 415, 440, 460, 480, 500, 690 V ❑ 60 Hz 208, 280, 380, 460, 480, 575 V Single phase ❑ 110, 115, 220, 240 V at 50, 60 Hz Direct Current ❑ 24, 48, 110 V Tolerance on fluctuations ❑ Voltage: ±10% continuous +10% -15% intermittent ❑ Frequency: ±2% Working temperature ❑ The standard range is -30°C to +85°C ❑ Extended ranges -40°C to +65°C ❑ Special low temperature range version -55°C to +65°C Storage temperature ❑ From -55°C to +85°C Environmental protections ❑ Only waterproof IP 68 according to EN60529 (15 m dept/90 hours), or alternatively NEMA 4, NEMA 4X and NEMA 6 according to NEMA ICS6 ❑ Standard explosionproof degree Ex-d IIB T4 according to IEC / EN60079 (-60°C/+85°C) IP 68 according to EN60529 (15 m dept/90 hours), or alternatively NEMA 4, NEMA 4X and NEMA 6 according to NEMA ICS6 ❑ Optional explosionproof degree 1. Ex-de IIB T4 according to IEC / EN60079 Working temperature range: -20° to +60°C IP 68 according to IEC 529 and CEI EN60529 (15 m dept/90 hours), or alternatively NEMA 4, NEMA 4X and NEMA 6 according to NEMA ICS6 2. Ex-d IIC T4 (-20°C/+60°C) (consult factory) Ex-de IIC T4 (-20°C/+60°C) (consult factory) Ex-de IIB +H2 T4 (-20°C/+60°C) (consult factory) IP 68 according to IEC 529 and CEI EN60529 (15 m dept/90 hours), or alternatively NEMA 4, NEMA 4X and NEMA 6 according to NEMA ICS6 !@#$ flow control 16 3. US/Canada Standards: FM/CSA Class I, Division 1, Groups C and D Class II, Division 1, Groups E, F and G Class III, Division 1, Groups E, F and G Temperature classes: T4A, -55°C to +60°C T4, -55°C to +70°C NEMA 4,4X and 6 Safety Compliance ❑ Electromagnetic compatibility directive (EMC) ICON2000 actuators conform to the requirements of EMC Directive 2004/108/EC and further amendments. ❑ Low voltage directive (LV) ICON2000 actuators conform with Low Voltage Directive 2006/95/EC and further amendments by the application of EN60204-1 1993. ❑ Machinery directive ICON2000 actuators comply with the provision of Machinery Directive 2006/42/EC. ❑ ATEX directive (94/9/EEC) ICON2000 v4 actuators are certified according to Ex II 2 GD. Test Summary ❑ Life test Standard ICON2000 life test is based on AWWA 540-93 for a minimum of 10,000 cycles. ❑ Vibration test ICON2000 are certified as per IEC 60068-2-6- Appendix B (plant induced): frequencies from 1 to 500 Hz (in 3 axes) with 2.0g peak acceleration. Sweep cycles in each axis: 10. ❑ Seismic test ICON2000 are tested in accordance with IEC 60068-2-57. Frequencies from 1 to 35 Hz (in 3 axes) with max 2.0g peak acceleration. Verification of structural integrity at 5g. Endurance of oscillogram: 30 seconds. ❑ Environmental test ICON2000 are tested according to the following standards: IEC 68-2-1 (cold) up to –55°C, IEC 68-2-2 (dry heat) up to +85°C, IEC 68-2-3 (damp heat) up to +40°C with 93% relative humidity. ❑ Salt spray test ICON2000 external coating is tested for resistance to salt spray for 1,500 hours according to ASTM B117/IEC 68-2-11. ❑ Noise test ICON2000 are tested according to EN21680. Noise level is less than 65 dB (grade A) at 1m distance. Motors Base version ICON2000 are equipped with three-phase asynchronous, squirrel cage, induction-type low-inertia balanced motors. For single phase or direct current supply, a special interface allows to use conventional asynchronous motors. The open frame is protected by an Explosionproof / Waterproof cover fixed on the actuator housing. Internal protection by a temperature sensor, inserted in the motor windings. The motor flange is directly coupled to the actuator housing with internal flying leads wired to an intermediate terminal board. Electric motors are supplied with insulation class F or H as standard with dedicated speed and temperature sensor. Cinematic reduction chain and lubrication Motor power is transmitted to the output hollow shaft directly via a high torque capability and high efficiency worm shaft/worm wheel reduction without any interposition of spur or helical gears. Output hollow shaft is with teeth termination in order to transmit only a torque to the stem nut. Lubrication is through oil bath (two oil plugs are provided for filling and draining). !@#$ flow control 17 Manual override All actuators are provided with a handwheel for manual operation. The de-clutching mechanism is designed so that motor operation always has priority over manual operation. Whenever the motor is started, the hand mechanism will automatically disengage without engaging the operator. The de-clutch lever is padlockable in two positions (only electrical or only manual) to prevent undesired operation. Terminal block Terminal block is located in a double sealed enclosure. The terminal block is provided with the following terminations and accessories: - 3 terminals for power supply - 46 terminals for controls - 2 for DC external supply - 2 for low voltage (max 230V) external supply - 1 external earth - 1 external neutral Cable entries Three cable entries are supplied as standard. One extra entry is optionally available. The standard thread is NPT and diameter is: - one with 11/2" - two with 1" - one with 3/4" (optional) ISO Rc 7/1, ISO metric BS3643 and DIN 40430/PG and different diameters are available as options. Data logger “Data logger” is available for collecting different types of data useful in maintenance or diagnostic programs. Since the amount of collected data is quite large, the data logger must be downloaded onto a Pc/Pda through Irda or BluetoothTM connection to be viewed. The main functions of the Data logger are: - RECORDER mode: measurement and memorisation of main voltage supply (V), motor temperature (C°), electronics compartment temperature (C°), with configurable sampling time and start date and time (up to 256 sets of measures can be memorised) - EVENT mode: memorisation of Open or Close commands, with indication of source, date and time. Configurable Start date and time. Up to 128 events can be memorised. !@#$ flow control 18 !@#$ flow control 19 A large variety of optional modules can be added to the base version. If the option you are looking for is not listed below, please contact Biffi. Fieldbus interfaces ICON2000 modular design is easily upgraded from base-to-base to bus versions. You just need to add the relevant plug-in card. ICON2000 flexible interface allows connection to the major field bus available on the market: Foundation Fieldbus Profibus DPV0, DPV1 and redundant DPV1 LonWorks Hart Modbus Options: DTM (Device process Manager) for process control system with FDT interface for Profibus DPV1. • EDD (Electronic Device description) for PDM for Profibus DPV1 • Removable Profibus connection. Please ask our Sales people for specific requirements. Position Servoamplifier Module (PSM) The module is necessary for actuators in modulating and inching duty. It drives the motor through pulses at constant frequency and duration proportional to the position error, following an externally set analogical point signal. The basic features are: Input: 4-20 mA or 0-20 mA with galvanic insulation Output: 4-20 mA with galvanic insulation for position or torque re-transmission. Three additional SPST output contacts to be configured "make or break". 2 interlock inputs. Position Analogue Retransmission Module (APTM) This card gives a 4-20 mA galvanically insulated module for position or torque retransmission. It is easily plugged in on the base card with no need for dedicated tools. The module can be configured to retransmitt the output torque in place of the actuator position. Solid state power switch over temperature (only for heavy modulation duty version) It detects power card maximum temperature condition and sets the relevant alarm. Extended temperature ranges -40/+70 °C by use of extended range components -60/+70 °C by use of a heating source for internal electronic components, powered by external supply. !@#$ flow control 20 Anticondensate heater The internal modules provide enough power to grant anticondensation protection for general applications. But when the environment air humidity reaches critical levels, an additional heater (10 Watt - 1500 Ohm, with external power supply) may be supplied on request. Battery Auxiliary batteries can be provided in an intrinsically safe enclosure. With auxiliary batteries it is possible to remotely transmit position also in case of power failure. Handwheel with reduction gearing Side-mounted handwheel with additional reduction, with engagement lever. The reduction on the manual operation reduces the torque at the handwheel. This provides less "rim-pull" force for the operator. The following ratios are applicable: model 030 040 050 ratio 10:1 13:1 17:1 Special couplings To be able to cope with different applications and working condition, two special couplings are available: - The linear coupling was designed for the motorization of valves with stem linear movement and no anti-rotational devices on the stem (e.g. application on modulating globe valves). This type of coupling converts multi-turn actuator rotational motion into linear motion: in this way the motorization is extremely simple and compact. - Spring-compensated coupling ASC type. The spring coupling block has its best application on actuators for wedge and globe valves working at high temperatures. The trim of valves working at temperatures higher than 450°C and subjected to large temperature changes undergoes expansions and contractions that are very dangerous to the valve and to the actuator thrust coupling. If, on the other hand, low temperatures are causing contractions, valve unseating could occur. The spring-compensated coupling is designed to cope with both high and low temperatures: the spring cups allows the stem nut to move axially. The same coupling can also be used in case of high speeds, as the springs reduce the over-strokes effects by absorbing the kinetic energy. !@#$ flow control 21 * Model 010 Depending on valve stroke Depending on valve stroke Models 020/030/040/050 Lever Position Detail AUTO Standard cable entries: a = 1” NPT b = 1 1/2” NPT MANUAL ICON2000 Series Overall Dimensions !@#$ flow control Model ICON-010 ICON-020 ICON-030 ICON-040 ICON-050 22 The information herein contained is reserved property of Biffi *and is subject to being modified without notice. A 484 597 699 815 958 a1 325 347 399 455 528 a2 159 159 159 159 159 B 561 579 621 686 750 b1 273 283 313 318 363 b2 288 296 308 368 387 ØC 300 500 600 720 860 F F10 F14 F14 F16 F25 H 332 380 436 486 560 h1 142 161 175 196 223 h2 152 161 175 191 218 h3 209 239 269 291 336 Mass Kg 32 45 70 86 110 Depending on valve stroke Lever Position Detail AUTO Standard cable entries: a = 1” NPT b = 1 1/2” NPT MANUAL ICON2000 Series Overall Dimensions (with reduced manual override) Model ICON-030 ICON-040 ICON-050 A 648 723 779 a1 399 455 528 a2 249 268 271 B 625 690 755 b1 313 318 363 b2 312 372 392 ØC 300 400 500 F F14 F16 F25 H 486 558 693 h1 171 196 223 h2 182 191 218 h3 263 284 336 Mass Kg 78 94 118 !@#$ flow control 23 Notes 1. The ** are to be replaced by RPM value at selected frequency (50 or 60 Hz) 2. Nominal output torque settable from 40% (minimum torque) to 100% of indicated value Multiturn Actuator Performances with 3-phase motors Model (1) ICON-010/30-** ICON-010/30-** ICON-010/30-** ICON-010/30-** ICON-010/30-** ICON-010/30-** ICON-010/30-** ICON-010/90-** ICON-010/90-** ICON-010/90-** ICON-010/90-** ICON-010/90-** ICON-010/90-** ICON-010/90-** ICON-020/180-** ICON-020/180-** ICON-020/180-** ICON-020/180-** ICON-020/180-** ICON-020/180-** ICON-020/180-** ICON-030/360-** ICON-030/360-** ICON-030/360-** ICON-030/360-** ICON-030/360-** ICON-030/360-** ICON-030/360-** ICON-040/720-** ICON-040/720-** ICON-040/720-** ICON-040/720-** ICON-040/720-** ICON-040/720-** ICON-040/720-** ICON-050/1440-** ICON-050/1440-** ICON-050/1440-** ICON-050/1440-** ICON-050/1440-** ICON-050/1440-** ICON-050/1440-** !@#$ flow control 24 Nom. Torque(2) (100%) (Nm) 30 30 30 30 30 30 30 90 90 90 90 90 90 90 180 180 180 180 180 180 180 360 360 360 360 360 360 360 720 720 720 720 720 720 720 1440 1440 1440 1440 1440 1440 1440 Min. Torque (Nm) 12 12 12 12 12 12 12 36 36 36 36 36 36 36 72 72 72 72 72 72 72 144 144 144 144 144 144 144 288 288 288 288 288 288 288 576 576 576 576 576 576 576 Max. Torque(3) (Nm) 45 45 45 45 45 45 45 135 135 135 135 135 135 135 270 270 270 270 270 270 270 540 540 540 540 540 540 540 1080 1080 1080 1080 1080 1080 1080 2160 2160 2160 2160 2160 2160 2160 (4) 3. Theoric max output torque. The actual max output torque is a function of speed and motor power supply and may vary from 1.4 to 2 times the nominal output torque 4. The above performances are referred to ON/OFF S2-15' or INCHING S4-25%-60 starts/hour duties (IEC60034-1) 5. Referred to Running torque = 40% Nominal torque - ON/OFF or Inching service RPM(5) (50 Hz) RPM(5) (60 Hz) Motor Type Motor Power (KW) at 50 Hz Motor Power (KW) at 60 Hz R 12 18 24 36 48 72 144 12 18 24 36 48 72 144 12 18 24 36 48 72 144 12 18 24 36 48 72 144 12 18 24 36 48 72 144 12 18 24 36 48 72 144 14 22 29 43 58 86 173 14 22 29 43 58 86 173 14 22 29 43 58 86 173 14 22 29 43 58 86 173 14 22 29 43 58 86 173 14 22 29 43 58 86 173 SM00 SM01 SM10 SM11 SM04 SM05 SM06 SM10 SM11 SM12 SM13 SM14 SM15 SM16 SM12 SM13 SM14 SM15 SM21 SM22 SM23 SM21 SM32 SM21 SM22 SM30 SM23 SM31 SM30 SM44 SM30 SM40 SM41 SM31 SM42 SM41 SM40 SM41 SM43 SM50 SM42 SM51 0.030 0.046 0.071 0.106 0.142 0.213 0.426 0.071 0.106 0.122 0.184 0.286 0.367 0.735 0.122 0.184 0.286 0.367 0.526 0.789 1.470 0.526 0.500 0.526 0.789 1.123 1.470 3.368 1.123 0.840 1.123 1.684 1.939 3.368 5.818 1.939 1.684 1.939 2.885 3.879 5.818 11.636 0.036 0.055 0.085 0.127 0.170 0.256 0.511 0.085 0.127 0.146 0.221 0.343 0.440 0.882 0.146 0.221 0.343 0.440 0.631 0.947 1.764 0.631 0.600 0.631 0.947 1.348 1.764 4.042 1.348 1.008 1.348 2.021 2.327 4.042 6.982 2.327 2.021 2.327 3.462 4.655 6.982 13.963 40:1 40:1 20:1 20:1 20:1 20:1 20:1 40:1 40:1 20:1 20:1 20:1 20:1 20:1 40:1 40:1 40:1 40:1 20:1 20:1 20:1 80:1 40:1 40:1 40:1 20:1 40:1 20:1 80:1 40:1 40:1 40:1 20:1 40:1 20:1 80:1 80:1 40:1 40:1 20:1 40:1 20:1 Notes 1. The ** are to be replaced by RPM value at selected frequency (50 or 60 Hz) 2. Nominal output torque settable from 40% (minimum torque) to 100% of indicated value 3. Theoric max output torque. The actual max output torque is a function of speed Multiturn Actuator Performances with 3-phase motors Model (1) ICON-010/30-** ICON-010/30-** ICON-010/30-** ICON-010/30-** ICON-010/30-** ICON-010/30-** ICON-010/30-** ICON-010/90-** ICON-010/90-** ICON-010/90-** ICON-010/90-** ICON-010/90-** ICON-010/90-** ICON-010/90-** ICON-020/180-** ICON-020/180-** ICON-020/180-** ICON-020/180-** ICON-020/180-** ICON-020/180-** ICON-020/180-** ICON-030/360-** ICON-030/360-** ICON-030/360-** ICON-030/360-** ICON-030/360-** ICON-040/720-** ICON-040/720-** ICON-040/720-** Nom. Torque(2) (100%) (Nm) 30 30 30 30 30 30 30 90 90 90 90 90 90 90 180 180 180 180 180 180 180 360 360 360 360 360 720 720 720 Min. Torque (Nm) 12 12 12 12 12 12 12 36 36 36 36 36 36 36 72 72 72 72 72 72 72 144 144 144 144 144 288 288 288 Max. Torque(3) (Nm) 45 45 45 45 45 45 45 135 135 135 135 135 135 135 270 270 270 270 270 270 270 540 540 540 540 540 1080 1080 1080 (4) and motor power supply and may vary from 1.4 to 2 times the nominal output torque 4. The above performances are referred to ON/OFF S2-30' or MODULATING S4-25%-600 starts/hour duties (IEC60034-1) 5. Referred to Running torque = 40% Nominal torque 6. Ambient temperature from -55°C to 65°C - Modulating service RPM(5) (50 Hz) RPM(5) (60 Hz) Motor Type Motor Power (KW) at 50 Hz Motor Power (KW) at 60 Hz R 12 18 24 36 48 72 144 12 18 24 36 48 72 144 12 18 24 36 48 72 144 24 36 48 72 144 24 36 72 14 22 29 43 58 86 173 14 22 29 43 58 86 173 14 22 29 43 58 86 173 29 43 58 86 173 29 43 86 TM00 TM01 TM10 TM11 TM04 TM05 TM06 TM10 TM11 TM12 TM13 TM14 TM15 TM16 TM12 TM13 TM14 TM15 TM21 TM22 TM23 TM21 TM22 TM30 TM23 TM31 TM30 TM40 TM31 0.030 0.046 0.071 0.106 0.142 0.213 0.426 0.071 0.106 0.122 0.184 0.286 0.367 0.735 0.122 0.184 0.286 0.367 0.526 0.789 1.470 0.526 0.789 1.123 1.470 3.368 1.123 1.684 3.368 0.036 0.055 0.085 0.127 0.170 0.256 0.511 0.085 0.127 0.146 0.221 0.343 0.440 0.882 0.146 0.221 0.343 0.440 0.631 0.947 1.764 0.631 0.947 1.348 1.764 4.042 1.348 2.021 4.042 40:1 40:1 20:1 20:1 20:1 20:1 20:1 40:1 40:1 20:1 20:1 20:1 20:1 20:1 40:1 40:1 40:1 40:1 20:1 20:1 20:1 40:1 40:1 20:1 40:1 20:1 40:1 40:1 40:1 !@#$ flow control 25 !@#$ flow control 26 Notes to couplings type A Model Ø d6 = Max threaded stem acceptance Ø dx = The maximum accepted diameter described by the key Fnom = The max thrust applicable to the ICON2000 block type “A” in dynamic conditions with torque control set at 100% Fmax = The max thrust applicable to the ICON2000 block type “A” in static conditions with manual override or with motor in stall torque ISO 5210 Fnom (KN) Fmax (KN) Ø d1 Ø d2 f8 Ø d3 Ø d4 Ø d5 Ø d6 max Ø d6 not machined Ø dx max l1 l2 h1 h2 N Weight (N) 010 F10 40 60 125 70 102 M10 33 32 18 32 40 51 3 15 4 15 020 F14 100 150 175 100 140 M16 46 45 19 45 55 68 4 24 4 75 030 F14 150 225 175 100 140 M16 62 60.5 26 60.5 70 84 4 24 4 75 040 F16 180 270 210 130 165 M20 68 65 30 65 75 94 5 30 4 150 050 F25 300 450 300 200 254 M16 78 76,5 35 77 95 120 5 24 8 275 Notes to couplings type B1/B2 Ø d7 = with standard keyway according to ISO 773 Ø dx = The maximum accepted diameter described by the key Notes to couplings type B3/B4 Ø d10 = with standard keyway according to ISO 773 Ø dx = The maximum accepted diameter described by the key Model ISO 5210 Ø d5 B1Ø d7 H9 B2Ø d7 max Ø dx max l3 l4 Mass (Kg) 010 F10 33 42 42 50 45 56 2 Model ISO 5210 B3Ø d10 H9 B4Ø dy max Ø dx l6 Mass (Kg) 010 F10 20 22 26 100 1 020 F14 46 60 60 71 65 85 7 020 F14 30 32 40 120 6 030 F14 62 60 60 71 65 84 7 040 F16 68 80 80 94 80 105 14 030 F14 30 46 55 130 6 040 F16 40 50 60 150 12 050 F25 78 100 100 116 110 155 26 050 F25 50 58 68 180 20 !@#$ flow control 27 block and terminals diagram General Configuration !@#$ flow control 28 !@#$ flow control 29 Bevel Gear Reducers For application on valves when a side-mounted multiturn actuator is requested. Penstocks are another typical application for this type of reducer. BGR Multiturn Actuator Performances with 3-phase motors(4) (1) Model BGR BGR-3-010/360-** BGR-3-010/360-** BGR-3-010/360-** BGR-3-010/360-** BGR-3-010/360-** BGR-7-020/720-** BGR-7-020/720-** BGR-7-020/720-** BGR-7-020/720-** BGR-7-020/720-** BGR-15-030/1440-** BGR-15-030/1440-** BGR-15-030/1440-** BGR-15-030/1440-** BGR-15-030/1440-** BGR-30-040/2880-** BGR-30-040/2880-** BGR-30-040/2880-** BGR-30-040/2880-** BGR-30-040/2880-** BGR-60-050/5760-** BGR-60-050/5760-** BGR-60-050/5760-** BGR-60-050/5760-** BGR-60-050/5760-** Nom Torque(2) (100%) (Nm) Min Torque (Nm) Max Torque (Nm) 360 360 360 360 360 720 720 720 720 720 1440 1440 1440 1440 1440 2880 2880 2880 2880 2880 5760 5760 5760 5760 5760 144 144 144 144 144 288 288 288 288 288 576 576 576 576 576 1152 1152 1152 1152 1152 2304 2304 2304 2304 2304 540 540 540 540 540 1080 1080 1080 1080 1080 2160 2160 2160 2160 2160 4320 4320 4320 4320 4320 8640 8640 8640 8640 8640 (3) BGR ratio RPM(5) (50 Hz) 4,50:1 4,50:1 4,50:1 4,50:1 4,50:1 4,50:1 4,50:1 4,50:1 4,50:1 4,50:1 4,50:1 4,50:1 4,50:1 4,50:1 4,50:1 4,50:1 4,50:1 4,50:1 4,50:1 4,50:1 4,50:1 4,50:1 4,50:1 4,50:1 4,50:1 5 8 11 16 32 5 8 11 16 32 5 8 11 16 32 5 8 11 16 32 5 8 11 16 32 RPM(5) Motor (60 Hz) Type 6 10 13 19 38 6 10 13 19 39 6 10 13 19 39 6 10 13 19 38 6 10 13 19 38 SM12 SM13 SM14 SM15 SM16 SM14 SM15 SM21 SM22 SM23 SM21 SM22 SM30 SM23 SM31 SM30 SM40 SM41 SM31 SM42 SM41 SM31 SM50 SM42 SM51 See notes for Multiturn Actuator Performances Notes to couplings type A Type “A” = The block having the capability to transmit both a torque and a thrust. = The max accepted Ø dx diameter described by the key l1 x1.10 = Minimum threaded valve stem protusion Fnom = The max thrust applicable to the BGR block type “A” in dynamic conditions with torque control set at 100% Fmax = The max thrust applicable to the BGR block type “A” in static conditions with manual override or with motor in stall torque !@#$ flow control 30 ICON2000 Series BGR Dimension ISO 5210 Fnom (KN) Fmax (KN) Ø d1 Ø d2 f8 Ø d3 Ø d4 Ø d5 Ø d6 max (dx) Ø d6 min l1 l2 h1 h2 N Weight (N) BGR 3 F14 150 225 175 100 140 M16 62 60.5 70 84 4 24 4 75 BGR 7 F16 180 270 210 130 165 M20 68 65 75 94 5 30 4 150 BGR 15 F25 300 450 300 200 254 M16 78 77 95 120 5 24 8 275 BGR 30 F30 440 660 350 230 298 22 78 77 51 110 134 5 30 8 480 BGR 60 F35 700 1050 415 260 356 33 97 96 55 144 172 5 40 8 750 Spur Gear Reducers For application on valves when a multiturn actuator is required and torque exceeds 1440 Nm. The spur gear reducer and its thrust block are designed for the severest duties. SGR Multiturn Actuator Performances with 3-phase motors(4) Nom Torque(2) Min Torque Max Torque (Nm) (100%) (Nm) (Nm) (1) Model SGR 2625 700 1750 SGR-160-030/1750-** 3225 860 2150 SGR-160-030/2150-** 4320 1152 2880 SGR-160-030/2880-** 4320 1152 2880 SGR-160-030/2880-** 5400 1440 3600 SGR-250-030/3600-** 5400 1440 3600 SGR-250-040/3600-** 7200 1920 4800 SGR-250-030/4800-** 7200 1920 4800 SGR-250-030/4800-** 7200 1920 4800 SGR-250-040/4800-** 7200 1920 4800 SGR-250-050/4800-** 11250 3000 7500 SGR-400-030/7500-** 11250 3000 7500 SGR-400-040/7500-** 11250 3000 7500 SGR-400-050/7500-** 14400 3840 9600 SGR-400-040/9600-** 14400 3840 9600 SGR-400-040/9600-** 14400 3840 9600 SGR-400-050/9600-** 14400 3840 9600 SGR-640-050/9600-** 22500 6000 SGR-640-040/15000-** 15000 24000 6400 SGR-640-050/16000-** 16000 28800 7680 SGR-640-050/19200-** 19200 28800 7680 SGR-640-050/19200-** 19200 33000 8800 SGR-1000-050/22000-** 22000 42000 SGR-1000-050/28000-** 28000 11200 55500 SGR-1000-050/37000-** 37000 14800 55500 SGR-1000-050/37000-** 37000 14800 60000 SGR-1600-050/40000-** 40000 16000 72000 SGR-1600-050/48000-** 48000 19200 85500 SGR-1600-050/57000-** 57000 22800 See notes for Multiturn Actuator Performances Notes to couplings type A ICON2000 Series SGR Type “A” = The block having the capability to transmit both a torque and a thrust. Ø dx = The max accepted diameter described by the key l1 x1.10 = Minimum threaded valve stem protusion Fnom = The max thrust applicable to the SGR block type “A” in dynamic conditions with torque control set at 100% Fmax = The max thrust applicable to the SGR block type “A” in static conditions with manual override or with motor in stall torque Dimension ISO 5210 Fnom (KN) Fmax (KN) Ø d1 Ø d2 f8 Ø d3 Ø d4 Ø d5 Ø d6 max (dx) Ø d6 min l1 l2 h1 h2 N Weight (N) SGR 160 F30 440 660 350 230 298 22 78 77 51 110 134 5 30 8 480 SGR 250 F35 700 1050 415 260 356 33 97 96 55 144 172 5 40 8 750 SGR 400 F35 1200 1800 415 260 356 33 109 108 60 178 201 5 45 8 1050 (3) SGR ratio 5,50:1 6,70:1 9,00:1 9,00:1 11,80:1 6,00:1 15,86:1 15,86:1 8,00:1 4,00:1 24,32:1 12,28:1 6,00:1 15,86:1 15,86:1 7,90:1 7,90:1 24,63:1 13,20:1 15,86:1 15,86:1 18,19:1 23,36:1 30,88:1 30,88:1 33,39:1 40,20:1 48,90:1 SGR 640 --2250 3375 475 300 406 39 130 127 75 216 250 8 45 16 1500 RPM(5) RPM(5) (50 Hz) (60 Hz) 31 26 10 19 15 29 5,5 11 22 43 7 14 29 5,5 11 22 22 7 13 5,5 11 9,5 7,4 2,8 5,6 5,2 4,3 3,5 26 21 8 16 12 24 4,5 9 18 36 6 12 24 4,5 9 18 18 6 11 4,6 9 7,9 6,2 2,3 4,7 4,3 3,6 2,9 SGR 1000 --3200 4800 500 330 425 M36 156 153 90 252 290 8 50 16 1950 ICON 2000 ICON_030 ICON_030 ICON_030 ICON_030 ICON_030 ICON_040 ICON_030 ICON_030 ICON_040 ICON_050 ICON_030 ICON_040 ICON_050 ICON_040 ICON_040 ICON_050 ICON_050 ICON_040 ICON_050 ICON_050 ICON_050 ICON_050 ICON_050 ICON_050 ICON_050 ICON_050 ICON_050 ICON_050 SGR 1600 --4500 6750 620 400 520 M45 188 180 95 307 354 8 58 16 2500 !@#$ flow control 31 Depending on valve stroke Lever Position Detail AUTO MANUAL Standard cable entries: a = 1” NPT b = 1 1/2” NPT SGR/ICON2000 Series Overall Dimensions Model SGR-160-030 SGR-250-030 SGR-250-040 SGR-250-050 SGR-400-030 SGR-400-040 SGR-400-050 SGR-640-040 SGR-640-050 SGR-1000-050 SGR-1600-050 !@#$ flow control 32 A 859 927 983 1056 980 1036 1109 1097 1171 1284 1580 a1 399 399 455 528 399 455 528 455 528 528 528 a2 270 320 320 320 373 373 373 405 405 456 602 a3 190 208 208 208 208 208 208 237 238 300 450 B 621 621 686 750 621 686 750 686 750 750 750 b1 313 313 318 363 313 318 363 318 363 363 363 b2 308 308 368 387 308 368 387 368 387 387 387 ØC 400 500 500 500 500 500 500 600 600 600 600 F F30 F35 F35 F35 F35 F35 F35 SPEC. SPEC. SPEC. SPEC. H 617 684 724 684 736 776 866 838 928 968 1040 h1 231 300 300 300 356 356 356 418 418 458 522 h2 380 380 420 380 380 420 510 420 510 510 510 h3 251 330 330 330 383 383 383 460 460 500 564 Weight Kg 127 154 170 194 232 248 272 288 312 417 752 Depending on valve stroke View from X ISO 5210 “F” size (see page 31) Lever Position Detail AUTO MANUAL Standard cable entries: a = 1” NPT b = 1 1/2” NPT SGR/ICON2000 Series Overall Dimensions (with reduced manual override) Model SGR-160-030 SGR-250-030 SGR-250-040 SGR-250-050 SGR-400-030 SGR-400-040 SGR-400-050 SGR-640-040 SGR-640-050 SGR-1000-050 SGR-1600-050 A 814 880 942 1012 934 995 1064 1057 1124 1240 1535 a1 354 354 416 484 354 415 484 415 482 484 483 a2 270 320 320 320 373 373 373 405 405 456 602 a3 190 208 208 208 208 208 208 238 238 300 450 B 679 678 742 809 678 741 809 743 807 809 808 b1 300 302 310 334 302 311 334 311 335 334 334 b2 379 376 432 475 376 430 475 432 472 475 474 ØC 300 300 400 500 300 400 500 400 500 500 500 H 717 748 828 977 817 884 1033 947 1091 1132 1196 h1 231 300 300 300 356 356 356 418 418 458 522 h2 486 448 528 677 461 528 677 528 673 674 674 h3 251 330 330 330 383 383 383 460 460 500 564 Weight Kg 135 162 178 202 240 256 280 296 320 425 760 !@#$ flow control 33 Worm Gear Reducers for Quarter Turn Valves For application on any type of quarter turn valves (ball, butterfly, plug...). The worm gear is designed to meet AWWA C-540 and other major standards. Notes 1. Insert bush supplied by BIFFI with unmachined bore. Machining of bore upon request 2. Fixing bolts or rods supplied by BIFFI only on request, minimum material class required 8.8 UNI37409, ASTM A320-L7 3. Any other coupling can be supplied on request 4. Flanges for models WGR-800, 1600 and 3200 have double PCD. ICON2000 Series WGR d7 Max Stem Acceptance Model WGR-100 WGR-200 WGR-400 WGR-800 WGR-800 WGR-1600 WGR-1600 WGR-3200 WGR-3200 WGR-3200 WGR-6300 ISO 5211 F14 F16 F16 F25 F30 F25 F30 F30 F35 F40 F40 !@#$ flow control 34 Insert Bush Ø d1 175 210 210 300 350 300 350 350 415 475 475 Ø d3 140 165 165 254 298 254 298 298 356 406 406 Ø d4 M16 M20 M20 M16 M20 M16 M20 M20 M30 M36 M36 N° 4 4 4 8 8 8 8 8 8 8 8 H 100 105 105 123 123 164 164 186 186 214 250 h2 16 20 20 16 20 16 20 20 30 36 36 Ø Pin 16 16 16 20 20 20 20 20 20 20 30 Ø d7 50 65 65 90 90 103 103 120 120 120 170 Ø dx 60 76 76 104 104 120 120 139 139 139 194 Lever Position Detail AUTO MANUAL Standard cable entries: a = 1” NPT b = 1 1/2” NPT WGR/ICON2000 Series Overall Dimensions Model WGR-100-010 WGR-200-010 WGR-400-010 WGR-800-020 WGR-1600-020 WGR-3200-020 WGR-3200-030 WGR-6300-020 WGR-6300-030 WGR-6300-040 A 499 540 690 722 808 880 980 1055 1090 1135 a1 90 121 121 150 160 250 250 305 305 305 a2 137 147 264 267 343 325 325 380 380 380 a3 272 272 305 305 305 305 405 370 405 450 B 446 497 518 565 597 703 750 823 851 858 b1 273 273 283 283 283 283 313 283 313 318 b2 288 288 296 296 296 296 308 296 308 368 ØC 300 300 500 500 500 500 600 500 600 720 D 86 119 119 130 162 243 243 303 303 303 F F14 F16 F16 F25 F25/F30 F30/F35 F30/F35 F40 F40 F40 H 387 378 400 407 400 415 478 460 523 580 h1 62 53 53 60 75 90 90 135 135 135 h2 115 109 109 135 165 180 180 270 270 270 Mass Kg 39 42 60 75 106 166 174 509 517 527 !@#$ flow control 35 WGR-Quarter turn Actuator Performances with 3-phase motors(4) Model WGR Nom Torque(2) (100%) (Nm) WGR-100/330-** WGR-100/330-** WGR-100/330-** WGR-100/330-** WGR-100/330-** WGR-100/330-** WGR-100-010/1000-** WGR-100-010/1000-** WGR-100-010/1000-** WGR-100-010/1000-** WGR-100-010/1000-** WGR-100-010/1000-** WGR-200-010/2000-** WGR-200-010/2000-** WGR-200-010/2000-** WGR-200-010/2000-** WGR-200-010/2000-** WGR-200-010/2000-** WGR-200-010/2000-** WGR-400-010/4000-** WGR-400-010/4000-** WGR-400-010/4000-** WGR-400-010/4000-** WGR-400-010/4000-** WGR-400-010/4000-** WGR-400-010/4000-** WGR-800-020/8000-** WGR-800-020/8000-** WGR-800-020/8000-** WGR-800-020/8000-** WGR-800-020/8000-** WGR-800-020/8000-** WGR-800-020/8000-** WGR-1600-020/16000-** WGR-1600-020/16000-** WGR-1600-020/16000-** WGR-1600-020/16000-** WGR-1600-020/16000-** WGR-1600-020/16000-** WGR-1600-020/16000-** WGR-3200-020/32000-** WGR-3200-020/32000-** WGR-3200-020/32000-** WGR-3200-020/32000-** WGR-3200-020/32000-** WGR-3200-020/32000-** WGR-3200-030/32000-** WGR-6300-020/63000-** WGR-6300-020/63000-** WGR-6300-020/63000-** WGR-6300-020/63000-** WGR-6300-030/63000-** WGR-6300-040/63000-** 330 330 330 330 330 330 1000 1000 1000 1000 1000 1000 2000 2000 2000 2000 2000 2000 2000 4000 4000 4000 4000 4000 4000 4000 8000 8000 8000 8000 8000 8000 8000 16000 16000 16000 16000 16000 16000 16000 32000 32000 32000 32000 32000 32000 32000 63000 63000 63000 63000 63000 63000 (1) (3) Max Torque (Nm) Op. Time/90° (secs at 50 Hz) 500 500 500 500 500 500 1500 1500 1500 1500 1500 1500 3000 3000 3000 3000 3000 3000 3000 6000 6000 6000 6000 6000 6000 6000 12000 12000 12000 12000 12000 12000 12000 24000 24000 24000 24000 24000 24000 24000 48000 48000 48000 48000 48000 48000 48000 94500 94500 94500 94500 94500 94500 63 42 31 21 16 10 63 42 31 21 16 10 125 83 63 42 31 21 10 155 103 78 52 39 26 13 229 153 114 76 57 38 19 466 311 233 155 117 78 39 623 467 311 233 156 78 42 700 525 350 175 96 39 See notes for Multiturn Actuator performances For actuators life-cycle please conctact Biffi !@#$ flow control 36 Model ICON ICON_010/30-12 ICON_010/30-18 ICON_010/30-24 ICON_010/30-36 ICON_010/30-48 ICON_010/30-72 ICON_010/90-12 ICON_010/90-18 ICON_010/90-24 ICON_010/90-36 ICON_010/90-48 ICON_010/90-72 ICON_010/90-12 ICON_010/90-18 ICON_010/90-24 ICON_010/90-36 ICON_010/90-48 ICON_010/90-72 ICON_010/90-144 ICON_010/90-12 ICON_010/90-18 ICON_010/90-24 ICON_010/90-36 ICON_010/90-48 ICON_010/90-72 ICON_010/90-144 ICON_020/180-12 ICON_020/180-18 ICON_020/180-24 ICON_020/180-36 ICON_020/180-48 ICON_020/180-72 ICON_020/180-144 ICON_020/180-12 ICON_020/180-18 ICON_020/180-24 ICON_020/180-36 ICON_020/180-48 ICON_020/180-72 ICON_020/180-144 ICON_020/180-18 ICON_020/180-24 ICON_020/180-36 ICON_020/180-48 ICON_020/180-72 ICON_020/180-144 ICON_030/360-144 ICON_020/180-36 ICON_020/180-48 ICON_020/180-72 ICON_020/180-144 ICON_030/360-144 ICON_040/720-144 Op. Time/90° (secs at 60 Hz 52 35 26 17 13 9 52 35 26 17 13 9 104 69 52 35 26 17 9 129 86 65 43 32 22 11 196 125 95 64 47 32 16 389 259 194 130 97 65 32 519 389 259 195 130 65 35 583 438 292 146 80 33 Model ICON ICON_010/30-14 ICON_010/30-22 ICON_010/30-29 ICON_010/30-43 ICON_010/30-58 ICON_010/30-86 ICON_010/90-14 ICON_010/90-22 ICON_010/90-29 ICON_010/90-43 ICON_010/90-58 ICON_010/90-86 ICON_010/90-14 ICON_010/90-22 ICON_010/90-29 ICON_010/90-43 ICON_010/90-58 ICON_010/90-86 ICON_010/90-173 ICON_010/90-14 ICON_010/90-22 ICON_010/90-29 ICON_010/90-43 ICON_010/90-58 ICON_010/90-86 ICON_010/90-173 ICON_020/180-14 ICON_020/180-22 ICON_020/180-29 ICON_020/180-43 ICON_020/180-58 ICON_020/180-86 ICON_020/180-173 ICON_020/180-14 ICON_020/180-22 ICON_020/180-29 ICON_020/180-43 ICON_020/180-58 ICON_020/180-86 ICON_020/180-173 ICON_020/180-22 ICON_020/180-29 ICON_020/180-43 ICON_020/180-58 ICON_020/180-86 ICON_020/180-173 ICON_030/360-173 ICON_020/180-43 ICON_020/180-58 ICON_020/180-86 ICON_020/180-173 ICON_030/360-173 ICON_040/720-173 WGR Ratio WGR flange ISO 5211 50:1 50:1 50:1 50:1 50:1 50:1 50:1 50:1 50:1 50:1 50:1 50:1 98:1 98:1 98:1 98:1 98:1 98:1 98:1 124:1 124:1 124:1 124:1 124:1 124:1 124:1 183:1 183:1 183:1 183:1 183:1 183:1 183:1 373:1 373:1 373:1 373:1 373:1 373:1 373:1 747:1 747:1 747:1 747:1 747:1 747:1 400:1 1680:1 1680:1 1680:1 1680:1 920:1 377:1 F14 F14 F14 F14 F14 F14 F14 F14 F14 F14 F14 F14 F16 F16 F16 F16 F16 F16 F16 F16 F16 F16 F16 F16 F16 F16 F25 + F30 F25 + F30 F25 + F30 F25 + F30 F25 + F30 F25 + F30 F25 + F30 F25 + F30 F25 + F30 F25 + F30 F25 + F30 F25 + F30 F25 + F30 F25 + F30 F30 + F35 F30 + F35 F30 + F35 F30 + F35 F30 + F35 F30 + F35 F30 + F35 F40 F40 F40 F40 F40 F40 Elga Scotch-yoke reducer for application on valves requiring high torques at stroke limits (Open/Close). Also used on quarter-turn valves when very high torques are required. Notes 1. The ** are to be replaced by operating time value at selected frequency (50 or 60 Hz) 2. Nominal output torque settable from 40% (minimum torque) to 100% of indicated value 3. Theoric max output torque. The actual max output torque is a function of speed and motor power supply and may vary from 1.3 to 2 times nominal output torque 4. The performances below are referred to ON/OFF S2-15' or INCHING S4-25%-60 starts/hour duties (IEC34-1) ELGA Actuator Performances with 3-phase motors(4) (2) Nom. Torque (100%) (Nm) Model(1) ELGA-14KR-020/94000-** ELGA-14KR-020/94000-** ELGA-14KR-020/94000-** ELGA-14KR-020/94000-** ELGA-14KR-020/94000-** ELGA-14KR-030/94000-** ELGA-14KR-040/94000-** ELGA-18KR-020/133000-** ELGA-18KR-020/133000-** ELGA-18KR-020/133000-** ELGA-18KR-020/133000-** ELGA-18KR-020/133000-** ELGA-18KR-030/133000-** ELGA-18KR-040/133000-** ELGA-32KR-030/266000-** ELGA-32KR-030/266000-** ELGA-32KR-030/266000-** ELGA-32KR-030/266000-** ELGA-32KR-040/266000-** ELGA-32KR-050/266000-** ELGA-50KR-030/334000-** ELGA-50KR-030/334000-** ELGA-50KR-030/334000-** ELGA-50KR-030/334000-** ELGA-50KR-040/334000-** ELGA-50KR-050/334000-** Break To Open Running End to open 94000 94000 94000 94000 94000 94000 94000 133000 133000 133000 133000 133000 133000 133000 266000 266000 266000 266000 266000 266000 334000 334000 334000 334000 334000 334000 54300 54300 54300 54300 54300 54300 54300 77000 77000 77000 77000 77000 77000 77000 156000 156000 156000 156000 156000 156000 197000 197000 197000 197000 197000 197000 82000 82000 82000 82000 82000 82000 82000 116000 116000 116000 116000 116000 116000 116000 238000 238000 238000 238000 238000 238000 300000 300000 300000 300000 300000 300000 (3) Max Torque (Nm) 141000 141000 141000 141000 141000 141000 141000 199500 199500 199500 199500 199500 199500 199500 399000 399000 399000 399000 399000 399000 501000 501000 501000 501000 501000 501000 Op. Time/90° Op. Time/90° (secs at (secs at 50 Hz) 60 Hz) 865 577 433 288 144 69 42 1330 887 665 443 222 133 57 1272 954 636 318 181 75 1280 960 640 320 152 65 721 481 361 240 120 58 35 1108 739 554 369 185 111 48 1060 795 530 265 151 63 1067 800 533 267 127 54 ICON2000 Model ICON-020/180-24(29) ICON-020/180-36(43) ICON-020/180-48(58) ICON-020/180-72(86) ICON-020/180-144(173) ICON-030/360-144(173) ICON-040/720-144(173) ICON-020/180-24(29) ICON-020/180-36(43) ICON-020/180-48(58) ICON-020/180-72(86) ICON-020/180-144(173) ICON-030/360-144(173) ICON-040/720-144(173) ICON-030/360-36(43) ICON-030/360-48(58) ICON-030/360-72(86) ICON-030/360-144(173) ICON-040/720-144(173) ICON-050/1440-144(173) ICON-030/360-36(43) ICON-030/360-48(58) ICON-030/360-72(86) ICON-030/360-144(173) ICON-040/720-144(173) ICON-050/1440-144(173) Motor Motor Power Motor Power Type (KW) at 50Hz (KW) at 60Hz SM14 SM15 SM21 SM22 SM23 SM31 SM42 SM14 SM15 SM21 SM22 SM23 SM31 SM42 SM22 SM30 SM23 SM31 SM42 SM51 SM22 SM30 SM23 SM31 SM42 SM51 0.286 0.367 0.526 0.789 1.470 3.368 5.818 0.286 0.367 0.526 0.789 1.470 3.368 5.818 0.789 1.123 1.470 3.368 5.818 11.636 0.789 1.123 1.470 3.368 5.818 11.636 0.343 0.440 0.631 0.947 1.764 4.042 6.982 0.343 0.440 0.631 0.947 1.764 4.042 6.982 0.947 1.348 1.764 4.042 6.982 13.963 0.947 1.348 1.764 4.042 6.982 13.963 !@#$ flow control 37 Notes 1. Insert bush supplied by BIFFI with unmachined bore. Machining of bore upon request 2. Different values of flange dimensions can be supplied on request 3. Female spigot supplied as a standard. Male spigot supplied on request. Model 1.5K without spigot 4. Fixing bolts or rods supplied by BIFFI only on request, minimum material class required 8.8 UNI37409, ASTM A320-L7 ICON2000 Series Elga d7 Max Stem Acceptance Model 14 18 32 50 80 ISO 5211 (2) F48 F60 F60 SPECIAL SPECIAL !@#$ flow control 38 Ø d1 580 680 780 800 890 Ø d2 (3) 250 290 290 315 370 Ø d3 483 603 603 698 813 Ø d4 (4) M36 M36 M36 M36 M42 N 12 20 20 24 24 h1 (3) 10 12 12 10 10 h2 29 32 32 32 37 H 340 350 400 430 585 With Insert Bush One Piece Bush Ø d7 Ø 160 Ø 160 Ø 180 Ø 200 Ø 250 Ø d7 Ø 200 Ø 220 Ø 230 Ø 255 Ø 300 Ø dx Ø 185 Ø 185 Ø 206 Ø 226 Ø 282 Ø dx Ø 228 Ø 250 Ø 260 Ø 285 Ø 338 Lever Position Detail AUTO MANUAL Standard cable entries: a = 1” NPT b = 1 1/2” NPT ELGA/ICON2000 Series Overall Dimensions Model 14KR-020 14KR-030 14KR-040 18KR-020 18KR-030 18KR-040 32KR-030 32KR-040 32KR-050 50KR-030 50KR-040 50KR-050 A 1623 1673 1704 1814 1864 1842 2174 2178 2159 2314 2344 2334 a1 536 536 536 584 584 584 663 663 663 710 710 710 a2 784 784 784 927 927 874 1131 1131 1066 1251 1251 1194 a3 303 353 384 303 353 384 353 384 430 353 383 430 B 773 800 808 853 880 888 970 978 1023 1010 1018 1063 b1 283 310 318 283 310 318 310 318 363 310 318 363 b2 300 311 344 300 311 344 311 344 393 311 344 393 ØC 500 600 720 500 600 720 600 720 860 600 720 860 D 200 200 200 230 230 230 270 270 270 300 300 300 F F48 F48 F48 F60 F60 F60 F60 F60 F60 SPEC. SPEC. SPEC. H 540 593 662 540 593 662 632 701 732 633 702 733 h1 193 193 193 193 193 193 232 232 232 233 233 233 h2 385 385 385 392 392 392 464 464 464 561 561 561 Weight Kg 660 685 701 825 850 866 1000 1016 1025 1220 1236 1245 !@#$ flow control 39 Linear Actuator ICON2000L For specific application on linear valves (gate, globe...) with non-threaded stem, generally to replace piston or diaphragm pneumatic actuators. Notes 1. The ** are to be replaced by Linear speed value at selected frequency (50 or 60 Hz) 2. Nominal output thrust settable from 40% (minimum thrust) to 100% of indicated value 3. Theoric max output thrust. The actual max output thrust is a function of speed and motor power supply and may vary from 1.3 to 2 times nominal output thrust 4. The performances below are referred to ON/OFF S2-15' or INCHING S4-25%-60 starts/hour duties (IEC34-1) 5. Referred to Running thrust = 40% Nominal thrust ICON2000L Linear Actuator Performances with 3-phase motors(4) Nominal Thrust(2) (100%) (KN) Model(1) ICON-010L/10-** ICON-010L/10-** ICON-010L/10-** ICON-010L/10-** ICON-010L/10-** ICON-010L/10-** ICON-010L/40-** ICON-010L/40-** ICON-010L/40-** ICON-010L/40-** ICON-010L/40-** ICON-010L/40-** ICON-020L/60-** ICON-020L/60-** ICON-020L/60-** ICON-020L/60-** ICON-020L/60-** ICON-020L/60-** ICON-030L/90-** ICON-030L/90-** ICON-030L/90-** ICON-030L/90-** ICON-030L/90-** ICON-030L/90-** ICON-040L/150-** ICON-040L/150-** ICON-040L/150-** ICON-040L/150-** ICON-040L/150-** ICON-040L/150-** !@#$ flow control 40 10 10 10 10 10 10 40 40 40 40 40 40 60 60 60 60 60 60 90 90 90 90 90 90 150 150 150 150 150 150 Min Thrust Max Thrust(3) (KN) (KN) 4 4 4 4 4 4 16 16 16 16 16 16 24 24 24 24 24 24 36 36 36 36 36 36 60 60 60 60 60 60 15 15 15 15 15 15 60 60 60 60 60 60 90 90 90 90 90 90 135 135 135 135 135 135 225 225 225 225 225 225 Linear Speed(5) Linear Speed(5) (mm/secs (mm/secs at 50Hz) at 60Hz) 0.6 0.9 1.2 1.8 2.4 3.6 0.6 0.9 1.2 1.8 2.4 3.6 0.8 1.2 1.6 2.4 3.2 4.8 1.0 1.5 2.0 3.0 4.0 6.0 1.6 2.4 3.2 4.8 6.4 9.6 0.7 1.1 1.4 2.2 2.9 4.3 0.7 1.1 1.4 2.2 2.9 4.3 1.0 1.4 1.9 2.9 3.8 5.8 1.2 1.8 2.4 3.6 4.8 7.2 1.9 2.9 3.8 5.8 7.7 11.5 Motor Type SM00 SM01 SM10 SM11 SM04 SM05 SM10 SM11 SM12 SM13 SM14 SM15 SM12 SM13 SM14 SM15 SM21 SM22 SM21 SM32 SM21 SM22 SM30 SM23 SM30 SM44 SM30 SM40 SM41 SM31 Mot. Power (KW) at 50 Hz 0.030 0.046 0.071 0.106 0.142 0.213 0.071 0.106 0.122 0.184 0.286 0.367 0.122 0.184 0.286 0.367 0.526 0.789 0.526 0.500 0.526 0.789 1.123 1.470 1.123 0.840 1.123 1.684 1.939 3.368 Mot. Power (KW) at 60 Hz 0.036 0.055 0.085 0.127 0.170 0.256 0.085 0.127 0.146 0.221 0.343 0.440 0.146 0.221 0.343 0.440 0.631 0.947 0.631 0.600 0.631 0.947 1.348 1.764 1.348 1.008 1.348 2.021 2.327 4.042 R 40:1 40:1 20:1 20:1 20:1 20:1 40:1 40:1 20:1 20:1 20:1 20:1 40:1 40:1 40:1 40:1 20:1 20:1 80:1 40:1 40:1 40:1 20:1 40:1 80:1 40:1 40:1 40:1 20:1 40:1 Notes 1. The stem is drawn in fully retracted position. 2. The stem end (Ø d8) is left hand thread 3. Only axial loads are permitted 4. Fnom is the maximum thrust applicable to the linear thrust block in dynamic conditions with torque control set at 100%. Fmax is the maximum thrust applicable to the linear thrust block in static conditions with manual override or with motor in stall torque ICON2000 Series Linear Model ISO 5210/DIN3358 Fnom (KN) Fmax (KN) Ø d1 Ø d2 f8 Ø d3 Ø d4 Ø d8 (left) h1 h2 l7 l2 l4 N S(Max stroke) Weight (N) 010L F10 40 60 125 70 102 M10 M20x1,5 3 15 200 25 35 4 100 100 020L F14 60 90 175 100 140 M16 M36x3 4 24 280 55 60 4 160 180 030L F14 80 135 175 100 140 M16 M36x3 4 24 320 55 60 4 200 220 040L F16 150 225 210 130 165 M20 M42x3 4 30 450 65 80 4 300 280 !@#$ flow control 41 Notes 1. The ** are to be replaced by Linear speed value at selected frequency (50 or 60 Hz) 2. Nominal output thrust settable from 40% (minimum thrust) to 100% of indicated value 3. Theoric max output thrust. The actual max output thrust is a function of speed and motor power supply and may vary from 1.3 to 2 times nominal output thrust 4. The performances below are referred to ON/OFF S2-30' or INCHING S4-25%-600 starts/hour duties (IEC34-1) 5. Referred to Running thrust = 40% Nominal thrust 6. Ambient temperature from -55°C to 65°C ICON2000L Linear Actuator Performances with 3-phase motors(4) Nominal Thrust(2) (100%) (KN) Model(1) ICON-010L/10-** ICON-010L/10-** ICON-010L/10-** ICON-010L/10-** ICON-010L/10-** ICON-010L/10-** ICON-010L/40-** ICON-010L/40-** ICON-010L/40-** ICON-010L/40-** ICON-010L/40-** ICON-010L/40-** ICON-020L/60-** ICON-020L/60-** ICON-020L/60-** ICON-020L/60-** ICON-020L/60-** ICON-020L/60-** ICON-030L/90-** ICON-030L/90-** ICON-030L/90-** ICON-030L/90-** ICON-040L/150-** ICON-040L/150-** ICON-040L/150-** !@#$ flow control 42 10 10 10 10 10 10 40 40 40 40 40 40 60 60 60 60 60 60 90 90 90 90 150 150 150 Min Thrust Max Thrust(3) (KN) (KN) 4 4 4 4 4 4 16 16 16 16 16 16 24 24 24 24 24 24 36 36 36 36 60 60 60 15 15 15 15 15 15 60 60 60 60 60 60 90 90 90 90 90 90 135 135 135 135 225 225 225 Linear Speed(5) Linear Speed(5) (mm/secs (mm/secs at 50Hz) at 60Hz) 0.6 0.9 1.2 1.8 2.4 3.6 0.6 0.9 1.2 1.8 2.4 3.6 0.8 1.2 1.6 2.4 3.2 4.8 2.0 3.0 4.0 6.0 3.2 4.8 9.6 0.7 1.1 1.4 2.2 2.9 4.3 0.7 1.1 1.4 2.2 2.9 4.3 1.0 1.4 1.9 2.9 3.8 5.8 2.4 3.6 4.8 7.2 3.8 5.8 11.5 Motor Type TM00 TM01 TM10 TM11 TM04 TM05 TM10 TM11 TM12 TM13 TM14 TM15 TM12 TM13 TM14 TM15 TM21 TM22 TM21 TM22 TM30 TM23 TM30 TM40 TM31 Mot. Power (KW) at 50 Hz 0.030 0.046 0.071 0.106 0.142 0.213 0.071 0.106 0.122 0.184 0.286 0.367 0.122 0.184 0.286 0.367 0.526 0.789 0.526 0.789 1.123 1.470 1.123 1.684 3.368 Mot. Power (KW) at 60 Hz 0.036 0.055 0.085 0.127 0.170 0.256 0.085 0.127 0.146 0.221 0.343 0.440 0.146 0.221 0.343 0.440 0.631 0.947 0.631 0.947 1.348 1.764 1.348 2.021 4.042 R 40:1 40:1 20:1 20:1 20:1 20:1 40:1 40:1 20:1 20:1 20:1 20:1 40:1 40:1 40:1 40:1 20:1 20:1 40:1 40:1 20:1 40:1 40:1 40:1 40:1 For any further information you may require please contact Biffi Sales office; tel. ++39-0523.944411, fax ++39-0523.943923, e-mail: sales@biffi.it !@#$ flow control Biffi reserves the right to modify contents without notice. 43 Re v. 7M ar 20 11 IC ON 20 00 -B UE Biffi Italia s.r.l. Headquarters, Sales department, 29017 Fiorenzuola d’Arda - Italy tel. +39 0523 944411 fax +39 0523 943923 e-mail biffi_italia@biffi.it website: www.biffi.it
Similar documents
Leica Macrofluo Technical Brochure
– Reflector disk for 5 filter blocks, 0-pixel technology = no pixel offset during change – Aperture and field diaphragm can be centered – Switchable blue filter BG 38 and UV light stop – Light trap...
More information