ceodeux - Firecorp
Transcription
ceodeux - Firecorp
CEODEUX FIRETEC B Series B0430 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION Working pressure p max. Temperature range Seat orifice size Material Valve body Inlet connection Outlet connection Dip tube connection Lever connection Burst disc 250 bar - 20°C + 60°C 12 mm brass C = 25E EN 629-1 A = W 21,8 x 1/14” DIN 477 G = M 16 x 1 M 10 p = has to be specified 03-6- fixed Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Manual pneumatic operated valves for fixed installations, CO2 and inert gases B CEODEUX Series B0430 FIRETEC A ORDERING When ordering please specify: • Series number • Burst disc pressure”p” • Options G C Manual lever M 10 Cable lever M 12 www rotarex.com CEODEUX Extinguisher V alves T echnology S.A. Valves Technology ROTAREX Group 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed • Safety pin • Safety pin and chain • Manual lever M 10 x 1 • Cable lever M 12 • Pyrotechnical release device • Closing plug G 3/8” Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten OPTIONS CEODEUX FIRETEC B Series B0439 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION Working pressure p max. Temperature range Seat orifice size Discharge rateCO2 Discharge rate Operating Material Valve body Inlet connection Outlet connection Dip tube connection Burst disc Electrical specifications: Operating voltage Power consumption 250 bar - 20°C + 60°C 7 mm 45 kg / min Kv = 0,69, Cv = 80 total discharge brass C = 25E EN 629-1 A = W 21,8 x 1/14” DIN 477 G = M 10 x 0,75 p = has to be specified 24 V DC 10 Watts 03-6- fixed Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Solenoid valves for fixed installations, CO2 Series B0439 Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten FIRETEC B OPTIONS • Operating: intermittent • Special inlet • Special outlet • Operating voltage 12 V DC or 230 V DC • Explosion / flame proof solenoid ORDERING When ordering please specify: • Series number • Burst disc pressure”p” • Options www rotarex.com CEODEUX Extinguisher V alves T echnology S.A. Valves Technology ROTAREX Group 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed CEODEUX CEODEUX FIRETEC B Series B0439 15 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION Working pressure p max. Temperature range Seat orifice size Discharge rateCO2 Discharge rate Operating Electrodes outside diameter Material Valve body Inlet connection Outlet connection Burst disc Electrical specifications: Operating voltage Power consumption Electronics Supply voltage Potential free output contacts Max switching voltage Max contact rating Protection class Max current consumption 250 bar - 20°C + 60°C 7 mm 45 kg / min Kv = 0,69; Cv = 80 total discharge, intermittent max 22 mm brass C = 25E EN 629-1 A = W 21,8 x 1/14” DIN 477 p = has to be specified 24 V DC/ 12 V DC 10 Watt 6 to 30 VDC 2 50 V ( non-inductive) 0,4 A IP 67 8 mA 03-6- fixed Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Solenoid valves for fixed CO2 installations, with integrated electronic contents control “DIMES” CEODEUX FIRETEC B Series B0439 15 OPTIONS ORDERING When ordering please specify: • Series number • Burst disc pressure “p” • Options • Release devices • Inner cylinder length “L” www rotarex.com CEODEUX Extinguisher V alves T echnology S.A. Valves Technology ROTAREX Group 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten • Operating: intermittent • Special inlet • Special outlet • Operating voltage 12 V DC or 230 V DC • Explosion / flame proof solenoid • Complete kit ( valve, cylinder, protection cap) • Alarm box • Calibration unit • Corresponding connection cables • Dimes simulator box CEODEUX FIRETEC B Series B0439 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION Working pressure p max. Temperature range Seat orifice size Discharge rate Operating Material Valve body Inlet connection Outlet connection Dip tube connection Electrical specifications: Operating voltage Power consumption 250 bar - 20°C + 60°C 7 mm Kv = 0,69, Cv = 80 total discharge brass C = 25E EN 629-1 A = W 21,8 x 1/14” DIN 477 G = M 10 x 0,75 24 V DC 10 Watts 03-6- fixed Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Solenoid valves for fixed installations, inert gases 200 bar FIRETEC B Series B0439 Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten CEODEUX OPTIONS • Operating: intermittent • Special inlet • Special outlet • Gauge • Gauge with integrated pressure switch • Pressure switch • Connection with check valve • Operating voltage 12 V DC or 230 V DC • Explosion / flame proof solenoid • Chemical gases, FM200, NOVEC etc... ORDERING www rotarex.com CEODEUX Extinguisher V alves T echnology S.A. Valves Technology ROTAREX Group 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed When ordering please specify: • Series number • Options CEODEUX FIRETEC B Series B0480 0 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION Working pressure p max. Temperature range Seat orifice size Material Valve body Inlet connection Outlet connection Dip tube connection Release device connection Burst disc 250 bar - 20°C + 60°C 12 mm brass C = 25E EN 629-1 A = W 21,8 x 1/14” DIN 477 G = M 16 x 1 B = M 42 x 1,5 p = has to be specified 03-6- fixed Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Differential pressure valves for fixed installations, CO2 B CEODEUX Series B0480 0 FIRETEC OPTIONS ORDERING A When ordering please specify: • Series number • Burst disc pressure “p” • Options • Release devices G C Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten • Special inlet • Special outlet RELEASE DEVICES Type Release device Manual / pneumatic 20 bar Pneumatic 20 bar Pneu. double piston 10 bar Electromagnetic 0,5 A Manual release www rotarex.com CEODEUX Extinguisher V alves T echnology S.A. Valves Technology ROTAREX Group 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed B04420065 B04420066 B04420076 B04425103 B04420100 CEODEUX FIRETEC B Series B0480 45 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION Working pressure p max. Temperature range Seat orifice size Electrodes diameter Material Valve body Inlet connection Outlet connection Dip tube connection Release device connection Burst disc Electronics Supply voltage Potential free output contacts Max switching voltage Max contact rating Protection class Max current consumption 250 bar - 20°C + 60°C 12 mm 22 mm brass C = 25E EN 629-1 A = W 21,8 x 1/14” DIN 477 G = M 16 x 1 B = M 42 x 1,5 p = has to be specified 6 to 30 VDC 2 50 V ( non-inductive) 0,4 A IP 67 8 mA 03-6- fixed Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Differential pressure valves for fixed CO2 installations with integrated electronic contents control “DIMES” CEODEUX FIRETEC B Series B0480 45 OPTIONS Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten • Complete kit ( valve, cylinder, protection cap) • Alarm box • Calibration unit • Corresponding connection cables • Dimes simulator box ORDERING When ordering please specify: • Series number • Burst disc pressure “p” • Options • Release devices • Inner cylinder length “L” RELEASE DEVICES Type Release device Manual / pneumatic 20 bar Pneumatic 20 bar Pneu. double piston 10 bar Electromagnetic 0,5 A Manual release www rotarex.com CEODEUX Extinguisher V alves T echnology S.A. Valves Technology ROTAREX Group 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed B04420065 B04420066 B04420076 B04425103 B04420100 CEODEUX FIRETEC B Series B0480 45 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION Temperature range Connector type - 20°C + 60°C 8 pole DIN45326, with screw locking Material Cable insulation connector PVC metal 03-6- fixed Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Various cables for installation of electronic contents control “DIMES” B CEODEUX Series B0480 45 FIRETEC TYPES a. connector only (8pin). article nr: 029900084 Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten b. 4 wire cable with 8 pins for single cylinder connection. article nr: 029900088 Modular system to connect multiple cylinders to 1 alarm box (possibility to connect more cables together to obtain the correct number) c. cable for serial cylinder connection with 4 pins. article nr: 029900089 d. cable for 2 cylinder serial connection. article nr: 029900079 e. cable for 3 cylinder serial connection. article nr: 029900080 f. cable for 4 cylinder serial connection. article nr: 029900081 g. cable for 8 cylinder serial connection. article nr: 029900082 www rotarex.com CEODEUX Extinguisher V alves T echnology S.A. Valves Technology ROTAREX Group 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed h. end connector for serial cylinder connections. article nr: 029900083 CEODEUX FIRETEC B Series B0480 45 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION Battery buffered Alarm functions Supply Max switching voltage Max contact rating Dimensions Weight Protection class 12 hrs Flash ( red) Horn (105 dBA) Changeover contact 230VDC / 0.04A / 50Hz 230 V 2A 17 x 9,5 x 17 cm 1,4 kg IP 40 03-6- fixed Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Alarm box for electronic contents control “DIMES” B CEODEUX Series B0480 45 FIRETEC Output Relais DIMES Horn Ballvalve Flash www rotarex.com CEODEUX Extinguisher V alves T echnology S.A. Valves Technology ROTAREX Group 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Pressureswitch IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed 230Vac Input CEODEUX FIRETEC B Series B0480 45 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION - Calibrating: Empty and Full - Adjusting: Alarm and Filling weight - Measuring: actual Contents (% and kg) - Testing: Switching Contacts Dimensions Weight Power supply Charger Batterytime DIMES-connection cable 21 x 11 x 4 cm 0,5 kg 4 x AA 1.2V NiMH (rechargeable batteries, Included) Included ca 30 hrs Included www rotarex.com CEODEUX ROTAREX Group IS O 9001 ISO CERTIFIED Extinguisher V alves Va T echnology S.A. Te 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Calibration unit for electronic contents control “DIMES” CEODEUX CEODEUX FIRETEC FIRETEC B Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten “DIMES” simulation box for calibration unit and alarm box B Series B0480 46 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION - Testing: Alarmbox functionality - Training: Control unit functions 6,5 x 10 x 6 cm 0,3 kg www rotarex.com CEODEUX Extinguisher V alves T echnology S.A. Valves Technology ROTAREX Group 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed Dimensions Weight CEODEUX FIRETEC B Series B0480 1 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION Working pressure p max. Temperature range Seat orifice size Material Valve body Inlet connection Outlet connection Dip tube connection Release device connection Standard burst disc 250 bar -20°C- + 60°C 12 mm brass C = 25E EN 629-1 A = W 21,8 x 1/14” DIN 477 G = M 16 x 1 B = M 42 x 1,5 p = 270 bar 03-6- fixed Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Valves for fixed installations, inert gases 200 bar B CEODEUX Series B0480 1 FIRETEC • Special inlet • Special outlet • Gauge • Gauge with integrated pressure switch • Pressure switch • Special burst disc • Chemical gases, FM200, NOVEC etc... A ORDERING When ordering please specify: • Series number • Burst disc pressure “p” • Options • Release devices G C Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten OPTIONS RELEASE DEVICES Type Release device Manual / pneumatic 20 bar Pneumatic 20 bar Pneu. double piston 10 bar Electromagnetic 0,5 A Manual release www rotarex.com CEODEUX Extinguisher V alves T echnology S.A. Valves Technology ROTAREX Group 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed B04420065 B04420066 B04420076 B04425103 B04420100 CEODEUX FIRETEC B Series B0480 2 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION Working pressure p max. Temperature range Seat orifice size Material Valve body Inlet connection Outlet connection Dip tube connection Release device connection Standard burst disc 340 bar - 20°C + 60°C 12 mm brass C = 25E EN 629-1 A = W 21,8 x 1/14” DIN 477 G = M 16 x 1 B = M 42 x 1,5 p = 450 bar 03-6- fixed Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Valves for fixed installations, inert gases 300 bar B CEODEUX FIRETEC OPTIONS • Special inlet • Special outlet • Gauge • Gauge with integrated pressure switch • Pressure switch • Special burst disc A ORDERING When ordering please specify: • Series number • Burst disc pressure “p” • Options • Release devices G C Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Series B0480 2 RELEASE DEVICES Type Release device Manual / pneumatic 20 bar Pneumatic 20 bar Pneu. double piston 10 bar Electromagnetic 0,5 A Manual release www rotarex.com CEODEUX Extinguisher V alves T echnology S.A. Valves Technology ROTAREX Group 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed B04420065 B04420066 B04420076 B04425103 B04420100 CEODEUX FIRETEC Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Check valve for function test B Series 0299 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION W21,8 x 1/14” Brass 029900075 www rotarex.com CEODEUX ROTAREX Group IS O 9001 ISO CERTIFIED Extinguisher V alves Va T echnology S.A. Te 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed Thread connection : Material : Article number: CEODEUX FIRETEC B Series B0481 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION Working pressure p max. Temperature range Seat orifice size Material Valve body Inlet connection Outlet connection Burst disc Gauge 140 bar - 20°C + 60°C 49 mm brass C = 3” - 12 UN A = 2 1/2” - 12 UN p = has to be specified has to be specified 03-6- fixed Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Valves for fixed installations ∅ 49mm for chemical gases CEODEUX FIRETEC B Series B0481 Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten OPTIONS • Special inlet • Special outlet • Gauge • Gauge with integrated pressure switch • Pressure switch • Special burst disc ORDERING When ordering, please specify: • Series number or attribution • Type of gas • Connections • Burst disc pressure “p” • Thread for dip tube connection “G” • Options RELEASE DEVICES Type Release device Manual / pneumatic 20 bar Pneumatic 20 bar Pneu. double piston 10 bar Electromagnetic 0,5 A Manual release www rotarex.com CEODEUX Extinguisher V alves T echnology S.A. Valves Technology ROTAREX Group 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed B04420065 B04420066 B04420076 B04425103 B04420100 CEODEUX FIRETEC B Series B0482 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION Working pressure p max. Temperature range Seat orifice size Material Valve body Inlet connection Outlet connection Burst disc Gauge 140 bar - 20°C + 60°C 33 mm brass C = 2 1/2” - 12 UN A = 1 7/8” - 12 UN p = has to be specified has to be specified 03-6- fixed Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Valves for fixed installations ∅ 33mm for chemical gases CEODEUX FIRETEC B Series B0482 Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten OPTIONS • Special inlet • Special outlet • Gauge • Gauge with integrated pressure switch • Pressure switch • Special burst disc ORDERING When ordering, please specify: • Series number or attribution • Type of gas • Connections • Burst disc pressure “p” • Thread for dip tube connection “G” • Options RELEASE DEVICES Type Release device Manual / pneumatic 20 bar Pneumatic 20 bar Pneu. double piston 10 bar Electromagnetic 0,5 A Manual release www rotarex.com CEODEUX Extinguisher V alves T echnology S.A. Valves Technology ROTAREX Group 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed B04420065 B04420066 B04420076 B04425103 B04420100 CEODEUX FIRETEC B Series B0442 www rotarex.com CEODEUX Extinguisher V alves T echnology S.A. Valves Technology 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Manual release device for series B0480 B0481 B0482 CEODEUX FIRETEC Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Manual, pneumatic release device for series B0480 B0481 B0482 B Series B0442 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION Connection Pneumatic connection Working pressure min: 20 bar for 300 bar systems 15 bar for CO2 and 200 bar systems 10 bar for systems B = M 42 x 1,5 E = G 1/8” p max = 340 bar p max = 250 bar p max = 150 bar E www rotarex.com R O TA R EX G r oup CEODEUX Extinguisher V alves T echnology S.A. Valves Technology 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed B CEODEUX FIRETEC Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Pneumatic release device 20 bar for series B0480 B0481 B0482 B Series B0442 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION Connection Pneumatic connection Working pressure min: 20 bar for 300 bar systems 15 bar for CO2 and 200 bar systems 10 bar for systems B = M 42 x 1,5 E = G 1/8” p max = 340 bar p max = 250 bar p max = 150 bar E www rotarex.com R O TA R EX G r oup CEODEUX Extinguisher V alves T echnology S.A. Valves Technology 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed B CEODEUX FIRETEC Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Pneumatic release device 10 bar for series B0480 B0481 B0482 B Series B0442 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION B = M 42 x 1,5 E = G 1/8” p max = 360 bar p max = 250 bar p max = 150 bar www rotarex.com R O TA R EX G r oup CEODEUX Extinguisher V alves T echnology S.A. Valves Technology 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed Connection Pneumatic connection Working pressure min: 10 bar for 300 bar systems 7,5 bar for CO2 and 200 bar systems 5 bar for systems CEODEUX FIRETEC Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Bleed valve B Series 02973 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION G1/8” ( G3/8” optional) Brass 029730019 www rotarex.com CEODEUX ROTAREX Group ISO 9001 CERTIFIED Extinguisher V alves Va T echnology S.A. Te 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed Thread connection : Material : Article number: CEODEUX FIRETEC Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Electromagnetic release device for series B0480 B0481 B0482 B Series B0442 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION B = M 42 x 1,5 24 VDC 0,5 A IP65 www rotarex.com R O TA R EX G r oup CEODEUX Extinguisher V alves T echnology S.A. Valves Technology 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed Connection Nominal voltage Nominal current Class CEODEUX CEODEUX FIRETEC FIRETEC B Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Reset tool for electromagnetic actuator B Series 0230 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION M42x1,5 Brass 023000064 www rotarex.com CEODEUX Extinguisher V alves T echnology S.A. Valves Technology ROTAREX Group 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed Thread connection : Material : Article number: CEODEUX FIRETEC Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Assembly pressure gauge, 40 mm B Series 02972 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION M = M 10 x 1 0 – 360 bar 40 mm www rotarex.com R O TA R EX G r oup CEODEUX Extinguisher V alves T echnology S.A. Valves Technology 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed Gauge connection Indication range Nominal size CEODEUX FIRETEC Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Assembly pressure gauge with integrated pressure switch, 50 mm B Series 02972 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION M = M10 x 1 50 mm gold-plated 4,5 to 24 VDC/ VAC 5 mA to 100 mA max 3W contact above switch point 200 bar 300 bar 180-360 bar 270-400 bar 180 bar 270 bar 185 bar 275 bar 160 bar 250 bar www rotarex.com R O TA R EX G r oup CEODEUX Extinguisher V alves T echnology S.A. Valves Technology 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed Gauge connection Nominal size Electrical Data: Contact pin and lug Switch voltage Switch current Contact load Switch type Working Pressure Indication range Nominal switch point Setting increasing pressure max decreasing pressure min CEODEUX FIRETEC B Series B0701 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION Working pressure p max. Temperature range Seat orifice size Operating Material Valve body Inlet connection Outlet connection Burst disc Electrical specifications: Operating voltage Power consumption 20 bar at 20°C - 20°C + 60°C 9.5 mm total discharge Nickel plated brass C = M30x1,5 A = G1/4 p = to be specified 24 V DC 9 Watts 03-9- fixed Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Solenoid valve for fixed installations, Water, powder, FM200, Novec CEODEUX FIRETEC B Series B0701 ORDERING When ordering please specify: • Series number • Burst disc pressure”p” • Options www rotarex.com CEODEUX Extinguisher V alves T echnology S.A. Valves Technology ROTAREX Group 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten OPTIONS • Special inlet • Special outlet CEODEUX FIRETEC B Series B0620 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION Thread connection : Material : Color: Dimensions : Weigth : Impact test : Max cylinder weight: Markings: W80 x 1/11” Polyamid 6.6 (special impact stabilizing material) Dark grey Ø 148 x 170 mm 350 gr. Approval acc. to EN 962 60kg • EN 962 • 3 stars logo • 60kg 03-6- fixed Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Plastic protection cap for valves FireDeTec IHP/DHP, B0439 and others CEODEUX Series B0620 www rotarex.com CEODEUX Extinguisher V alves T echnology S.A. Valves Technology ROTAREX Group 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten FIRETEC B CEODEUX FIRETEC B Series B0620 ST ANDARD SPECIFICA TION STANDARD SPECIFICATION Thread connection : Material : Color: Dimensions : Weigth : Impact test : Max cylinder weight: Markings: W80 x 1/11” Steel Dark grey RAL 7037 Ø176 x 215 mm 3,6kg Approval acc. to EN 962 150kg • EN 962 • 3 stars logo • 150kg 03-6- fixed Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten Steel protection cap CEODEUX FIRETEC B Series B0620 ORDERING www rotarex.com CEODEUX Extinguisher V alves T echnology S.A. Valves Technology ROTAREX Group 24, Route de Diekirch, B.P. 19, L-7505 Lintgen (EUROPE) IS O 9001 ISO CERTIFIED Tel.: *352-32 78 32-232 Fax: *352-32 78 32-326 03-6- fixed Droits de modifications réservés / All rights of change reserved / Änderungsrechte vorbehalten When ordering, please specify: • Series number or attribution
Similar documents
rotarex deutschland gmbh
ROTAREX offers products for the use in Laser applications, ranging from simple single stage regulators to precision double stage regulators and switchover boards for constant gas supply.
More information